Single and Multi-Function Aquastat Controllers

Size: px
Start display at page:

Download "Single and Multi-Function Aquastat Controllers"

Transcription

1 L4006; L6006 Aquastat Controller Aquastat Controllers are iersion type devices for limiting or regulating the of liquids in boilers, storage tanks, and other applications where control is required. Totally enclosed Micro Switch snap-acting switches operate on rise to setpoint. Visible control point scale and external adjustment screw permit easy setting. or vertical insertion of the sensing element. Direct or well iersion of the sensing element. Models available for strap-on mounting. Remote bulb model may be used to sense air in ducts and in outside air sensing applications. TRADELINE models include heat-conductive compound. Select models have wells. Indoor Air Quality L4006A L4006E Combustion Hydronic L4006,H and L6006A,C Dimensions in inches (millimeters) 5/6 (8) (5) KNOCKOUT FOR /4 (9 ) CONDUIT ON ALL MODELS. SIMILAR KNOCKOUT ON OTTOM FOR HORIZONTAL INSERTION AND REMOTE UL MODELS. (5) /6 -/8 (54) (5) Case Dimensions: 5 5/8 in. high x in. wide x /8 in. deep (4 high x 5 wide x 54 deep) Maximum Ambient Temperature: 50 F (66 C) Operating Temperature Range: (00 F to 40 F 8 C to 6 C) American Gas Association IAS: AGA Certified Canadian Standards Association: Certified: File No. LR959- Underwriters Laboratories Inc. UL Component Recognized: File No. MP466, Vol. 6, Sec., Guide No. MPR uilding Automation 5-5/8 (6) -7/8 (48) KNOCKOUT FOR /4 (9) CONDUIT ON VERTICAL INSERTION MODELS ONLY /4 (9) RESET UTTON (L4006E, L4008E ONLY) ELEMENT FOR VERTICAL IMMERSION /6 (8) ELEMENT FOR HORIZONTAL IMMERSION /4 (9) M8957A Coercial Components Pneumatic

2 Product Number Electrical Ratings (Full Load) (Locked Rotor) (Millivolt) L4006A009 L4006A07 L4006A L4006A678 L4006A Vac; Vac 40 Vac; 0 Vac 40 Vac; 0 Vac to Vdc L4006A967 L4006A007 L4006A48 L L L40066 L4006E Vac; 0 Vac 40 Vac; 0 Vac to Vdc to Vdc L4006E09 L4006E09 L4006E7 40 Vac; 0 Vac 40 Vac; 0 Vac L4006H004 L6006A004 L6006A to Vdc L6006A45 L6006A44 L6006C08 L6006C Vac; 0 Vac 40 Vac; 0 Vac Product Number L4006A009 L4006A07 L4006A Application High or Low limit High or Low limit High or Low limit * L4006A678 High or Low limit * L4006A959 High or Low limit * L4006A967 High or Low limit Differential Temperature ulb Size Spud Size Insulation Depth (F) (C) (inch) () (inch) () (inch) () 5 F Fixed 5 F to 0 F 5 F Fixed 5 F to 0 F F fixed 5 F to 0 F C fixed C to 7 C C fixed C to 7 C C fixed C to 7 C * TRADELINE models SUPER TRADELINE models /4 in. /4 in. /4 in. /4 in / in. / in. Switching Action 8 SPST, 8 SPST, in. 76 SPST, in. 76 SPST, /4 in. 9 in. 76 SPST, /4 in. 9 / in. 8 SPST, Mounting Includes / in. (8 ) insulation / in. (8 ) insulation in. (76 ) insulation, stop factory-set at 60 F (7 C). in. (76 ) insulation, stop factory-set at 40 F (6 C), and heatconductive compound. / in. (8 ) insulation and heatconductive compound. / in. (8 ) insulation, stop factory-set at 40 F (6 C). 78 customer.honeywell.com

3 Product Number L4006A007 High or Low limit L4006A48 High or Low limit 5 F to 0 F 5 F to 0 F L Circulator 5 F Fixed * L Circulator 5 F to 0 F L40066 Circulator 5 F to 0 F * L4006E067 High Limit; L4006E09 L4006E09 L4006E7 L4006E5 Application High Limit; High Limit; High Limit; High Limit; * L4006H004 High Limit; strap-on mounting on well mount. L6006A004 Circulator Control and High Limit or Low Limit L6006A0 Circulator Control and High Limit or Low Limit L6006A45 Circulator Control and High Limit or Low Limit C to 7 C C to 7 C C fixed C to 7 C C to 7 C 5 F C 5 F to 0 F 5 F to 0 F C to 7 C C to 7 C * TRADELINE models SUPER TRADELINE models Differential Temperature ulb Size Spud Size /4 in. 9 in. 76 SPST, /4 in. 9 in. 76 SPST, / in. / in. 8 SPST, make on in. 76 SPST, make on in. 76 SPST, make on in. 76 SPST, in. 76 SPST, / in. to in. less well /4 in / in. 8 to 76 SPST, 8 SPST, in. 76 SPST, / in. Insulation Depth (F) (C) (inch) () (inch) () (inch) () Switching Action 8 SPST, / in. SPDT / in. SPDT Mounting Includes in. (76 ) insulation / in. (8 ) insulation in. (76 ) insulation, stop factory-set at 40 F (6 C), and heatconductive compound. in. (76 ) insulation. in. (76 ) insulation, stop factory-set at 50 F ( C); well adapter and heat-conductive compound. in. (76 ) insulation. racket for strap-on mounting, stop factory-set at 40 F (6 C), and heatconductive compound. in. 76 SPDT Stop factory-set at 40F (6 C) and heat-conductive compound Indoor Air Quality Combustion Hydronic uilding Automation Coercial Components Pneumatic

4 Product Number L6006A44 Circulator Control and High Limit or Low Limit * L6006C08 Circulator Control and High Limit or Low Limit L6006C059 Application Circulator Control and High Limit or Low Limit 5 F to 0 F 5 F to 0 F 5 F to 0 F C to 7 C C to 7 C C to 7 C * TRADELINE models SUPER TRADELINE models Differential Temperature ulb Size Spud Size Insulation Depth (F) (C) (inch) () (inch) () (inch) () Switching Action in. 76 SPDT Mounting Includes SPDT or Straponmounting SPDT 80 customer.honeywell.com

5 L4008; L6008 Remote ulb Controller Aquastat Controllers are iersion type devices for limiting or regulating the of liquids in boilers, storage tanks, and other applications where control is required. Remote sensing element detects and responds rapidly to changes. Totally enclosed Micro Switch snap-acting switch. Visible control point scale and external adjustment screw permit easy setting. or vertical mounting of the remote element into boiler, tank, or other container. Case mounts to a vertical surface. Indoor Air Quality Dimensions in inches (millimeters) 4-/6 (06) 5/6 (4) /8 (0) -/4 () SENSING ELEMENT CAPILLARY Product Number Application L4008A05 High or Low limit 5 F to 0 F L4008A0 High or Low limit 5 F to 0 F L40080 Circulator 5 F to 0 F * L4008E56 High Limit; * L4008E05 High Limit; L4008E High Limit; ALTERNATE POSITION OF SENSING ELEMENT CAPILLARY MOUNTING HOLE FOR /6 IN. (5 MM) SCREW () /64 (5) () ALTERNATE POSITION OF SENSING ELEMENT CAPILLARY M88 Differential Temperature ulb Size Case Dimensions: 5 5/8 in. high x in. wide x /8 in. deep (4 high x 5 wide x 54 deep) Maximum Ambient Temperature: 50 F (66 C) Operating Temperature Range: 00 F to 40 F (8 C to 6 C) Electrical Ratings: 40 Vac; 0 Vac (Full Load), 40 Vac; 0 Vac (Locked Rotor), 0.5 to Vdc (Millivolt) Canadian Standards Association: Certified: File No. LR959- Underwriters Laboratories Inc. UL Component Recognized: File No. MP466, Vol. 6, Sec., Guide No. MPR Capillary Length (F) (C) (inch) () (inch) * TRADELINE models SUPER TRADELINE models C to 7 C C to 7 C C to 7 C 0 x 7 0 x 7 0 x 7 0 x 7 0 x 7 0 x 7 Switching Action Mounting Includes 66 in. SPST, 0 in. SPST, 66 in. SPST, make on 66 in. SPST, 66 in. SPST, 66 in. SPST, or Vertical or Vertical or Vertical or Vertical or Vertical or Vertical 5 / ft (.7 m) capillary. 0 ft (.04 m) capillary; factory-set stop at 00 F (9 C). 5 / ft (.7 m) capillary. 5 / ft (.7 m) capillary; factory-set stop at 50 F ( C); heat-conductive compound Combustion Hydronic uilding Automation Coercial Components Pneumatic

6 Product Number Application * L6008A9 Circulator Control and Low Limit L6008A4 Circulator Control and Low Limit Differential Temperature 5 F to 0 F 5 F to 0 F * TRADELINE models SUPER TRADELINE models C to 7 C C to 7 C ulb Size 0 x 7 0 x 7 Capillary Length (F) (C) (inch) () (inch) Switching Action Mounting Includes 66 in. SPDT or Vertical 66 in. SPDT or Vertical 66 in. capillary 66 in. capillary 8 customer.honeywell.com

7 L40 Combination Aquastat and High Limit Controller The L40A, is an iersion-type controller for oil-fired water heaters. The Aquastat Controller senses water and cycles the burner through the oil primary. The high-limit controller breaks the circuit to the burner on a rise past the factory-set setpoint. The L40C is an iersion-type controller for gas systems that provides water regulation. The high-limit controller breaks the circuit to the burner on a rise past the factory-set setpoint. L40A,,C have a sensing element and a high limit sensor with automatic reset. Mounts on a horizontal iersion well in water heater wall. Adjustable setting scale. Fluid-filled element operates SPST, Micro Switch snap-acting switch. Integral, nonadjustable high limit. L40C is an iersion controller for gas systems. L40A, is an iersion controller for oil systems. Dimensions in inches (millimeters) 4-/ (04) Case Dimensions: 4 / in. wide x 7/8 in. high x /6 in. deep (04 wide x 99 high x 68 deep.) Operating Temperature Range: 00 F to 40 F stop set at 50 F (Scale marked- Hot-Normal-Warm); (8 C to 6 C stop set at 66 C (Scale marked- Hot-Normal-Warm) Product Number KNOCKOUT FOR / INCH CONDUIT (6) -/64 (5) -/6 (0) Application -/64 () -7/8 (99) -/64 () /4 (9) -/8 (5) -/6 (46) -/6 (68) WELL-CLAMP SCREW INSULATION DEPTH -/4 OR 4 (57 OR 0) /4-4 MAXIMUM INSERTION -/8 OR 5 (86 OR 7) M6806A Differential Temperature Spud Size Insulation Depth (F) (C) (inch) () (inch) () L40A09 High Limit 7 F ± 4 F.9 C ± C /4 in. 9 L40A00 High Limit 7 F ± 4 F.9 C ± C /4 in. 9 Electrical Ratings: 5A@ 40 Vac; 0 Vac (Full Load), 40 Vac; 0 Vac (Locked Rotor) Underwriters Laboratories Inc. UL Component Recognized: File No. MP466, Guide No. MPR. Switching Action 4 in. 0 SPST, /4 in. 57 SPST, Mounting Mounts on a horizontal iersion well in water heater wall. Mounts on a horizontal iersion well in water heater wall. Indoor Air Quality Combustion Hydronic uilding Automation Coercial Components Pneumatic

8 L800 Aquastat Controller L800A,, and C are iersion type controllers for regulating and limiting the tank in water heaters. As the water rises past the setpoint, the controller switches off the gas valve. Regulates and provides energy cutoff (ECO) action on a rise past the setpoint. Includes a second sensing element that senses average water to minimize stacking. Fluid-filled element operates Micro Switch SPST snap-acting switch. ECO switch interrupts the thermocouple circuit or main valve before tank reaches 0 F (99 C) maximum. Includes factory-installed iersion well on controller. Internal adjustment screw. Special switch terminal provides three-wire hookup from Aquastat controller to gas valve. Dimensions in inches (millimeters) TANK WALL / OR /4 4 C A A INSULATION DEPTH INSERTION DEPTH C WELL DIAMETER CONTROLLER WELL REMOTE WELL IN. MM IN. MM -/4 57 -/ OR -/ 8 OR /6 7/6 M4746 Case Dimensions: 5 5/8 in. high x in. wide x /8 in. deep (6 high x 5 wide x 54 deep) Electrical Ratings: A maximum at 4 VAC Temperature Rating (ECO) Energy Cutoff: 90 F Maximum Ambient Temperature: Maximum Tank: 0 F (Maximum Tank: 99 C) Operating Temperature Range: 00 F to 80 F; (8 C to 8 C) American Gas Association IAS: Design Certified: Report Number - Canadian Standards Association: Underwriters Laboratories Inc. UL Component Recognized: File No. MP466, Guide No. MPR 84 customer.honeywell.com

9 Product Number Differential Temperature ulb Size Application (F) (C) (inch) () (inch) (inch) () L80007 High Limit Controller: 5 F, fixed. Controller: C fixed; Energy Cutoff energy cutoff Switch: 0 F, switch: C fixed. fixed. L High Limit Controller: 5 F, fixed. Controller: C fixed; Energy Cutoff energy cutoff Switch: 0 F, switch: C fixed. fixed. L8008 High Limit Controller: 5 F, fixed. Controller: C fixed; Energy Cutoff energy cutoff Switch: 0 F, switch: C fixed. fixed. Capillary Length Insulation Depth /8 in. 0 4 in. Controller well: /4 in. remote well: / or / in. /8 in in. Controller well: /4 in. remote well: / or / in. Controller well: 57, remote well: 8 or 64 Controller well: 57, remote well: 8 or 64 Switching Action Mounting Includes SPST, SPST, /8 in. 0 9 in. / in. 8 SPST, Iersion Well Iersion Well Iersion Well Two zinc plated wells and one well clamp for remote well. Indoor Air Quality Combustion Hydronic uilding Automation Coercial Components Pneumatic

10 L408; L608 Multiple Aquastat Controllers High limit, low limit and/or circulator controllers used to regulate boiler water in gas- or oil-fired hydronic heating systems. An iersion type liquid-filled sensing element actuates two snap switches. One switch operates as a high limit control. The other switch operates as a low limit and/or circulator control, depending on the model. Controller may be mounted in any positioning and needs no leveling. Separate, easy-to-read, calibrated dial and setpoint adjustments for each switch. Differential adjustment on low limit or circulator switch. All adjustments accessible inside front cover. Push-in terminals for quick connecting. Cover Controller Single sensing element for easy installation. One SPST and one SPDT snap switches act independently at respective settings. Dimensions in inches (millimeters) 86 customer.honeywell.com

11 CAD CELL R484D PROTECTORELAY CONTROL F SOLID STATE SWITCH SS K SAFETY SWITCH HEATER K K LACK ORANGE JUNCTION OX URNER MOTOR OIL VALVE IGNITION Indoor Air Quality F 4V THERMOSTAT L L (HOT) 4 R T T R RA89A SWITCHING RELAY WHITE R L608A R W JUMPER ADDED CIRCULATOR POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. Combustion Hydronic Dimensions, Approximate: 7/8 in. high x 4 /8 in. wide x /4 in. deep (98 high x 05 wide x 70 deep.) Electrical Ratings (ignition): Transformer Load: 60 VA Maximum Ambient Temperature: 50 F at switches; 65 F at sensing element (66 C at switches; 9 C at sensing element) Operating Range, High Limit: 0 F to 40 F (54 C to 6 C) Operating Range, Low Limit: 0 F to 0 F (4 C to 04 C) Product Number Application Differential Temperature L408A0 High and Low limit High limit: 0 F fixed; low limit: 0-5 F L4080 High Limit and Circulator L High Limit and Circulator L High Limit and Circulator TERMINALS ARE TA TERMINALS. M8855 Operating Humidity Range (% RH): 0 to 95% RH, non-condensing Canadian Standards Association: Certified: File No. LR959- Underwriters Laboratories Inc. UL Listed: File No. MP466, Vol., Sec. 4, Guide No. MPR Insulation Depth Spud Size (F) (inch) () (inch) / in. 8 /4 in F fixed in. 76 /4 in. - 4 High limit: 0 F fixed; low limit: 0-5 F / in. 8 /4 in. - 4 Switching Action Mounting Includes SPST: High & Low Limit SPST: High Limit & Circulator SPST: High Limit & Circulator 0 F fixed in. 76 SPST: High Limit & Circulator * L608A00 High and Low limit 0 F fixed in. 76 /4 in. - 4 * L608A06 High and Low limit High limit: 0 F fixed; low limit: 0-5 F * TRADELINE models SUPER TRADELINE models / in. to 4 in. 8 /4 in. - 4 in. insertion well. uilding Automation Coercial Components Pneumatic

12 L748 Electronic Aquastat Controller Replaces the function of the bulb and capillary electromechanical Aquastat Controller with electronic sensing and microprocessor controlled relays. Dimensions, Approximate: 6 in. high x 4 / in. wide x in. deep (5 high x 4 wide x 5 deep) Anticipator Setting: 0. A Electrical Ratings (ignition): Transformer Output: nominal 4 Vac Maximum Power Consumption: 0 VA Voltage: 4 Vac Frequency: 60 Hz Electrical Connections: Quick-connect terminals Maximum Ambient Temperature: 50 F with.0 A 4 V load (66 C with.0 A 4 V load) Electrical Ratings Product Number Combination Aquastat and high limit controller is intended for use in gas-fired boilers using a 4 Vac burner circuit with vestibules for a wiring enclosure. Can replace a Honeywell L4080 High Limit and R885 Transformer Relay. Used in gas boilers where ignition controls such as the Honeywell S8600 Spark Ignition or SV9500/SV950 SmartValve controls or standing pilot gas controls such as the Honeywell VR800 are powered from 4 Vac. An external 0 Vac to 4 Vac transformer with 0 VA minimum is required to power the L748F. For total external transformer VA requirements, add the 0 VA requirements for the control, gas valve load requirement (connections, ), zone valve connection requirement (see zone valve specifications), vent damper requirement and VA requirement for any other equipment. Total low voltage load must not exceed 4A. Available with quickconnect or AMP plug connections. W, R and C terminals are provided in a terminal block with screw connections. Minimum Ambient Temperature: -0 F (-9 C) Setpoint Temperature Range: 40 F to 0 F (60 C to 04 C) Operating Range, High Limit: 40 F to 0 F (60 C to 04 C) Operating Humidity Range (% RH): 0 to 95% RH, non-condensing Underwriters Laboratories Inc. UL Component Listed: File No. MP466; Canadian UL Component Recognized: File No. MP466 (burner AFL) (circulator AFL) (circulator ALR) L748F Vac Vac Vac Differential Temperature Product Number Application (F) Mounting L748F075 Oil Aquastat Controller 0 F fixed ± F Vestibule mount 88 customer.honeywell.com

13 L84 Triple Aquastat Relay Vertical Dimensions in inches (millimeters) Single and Multi-Function Aquastat Controllers Vertical Iersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water service. Iersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems. Provide multizone control by using a separate circulator and R845 Relay for each zone. Include diaphragm powerhead and Micro Switch assembly that respond to changes in boiler water. Mount directly to boiler. Select models include large transformers and extra terminals for supplying power to low voltage zone valves. Require 4 Vac thermostat with heat anticipator set at 0. A (plus current draw of gas valve on L84E). TRADELINE models include tube of heat conductive compound and range stops. LOW VOLTAGE THERMOSTAT L84A,C G Indoor Air Quality Combustion Hydronic T T L (HOT) K W R LOW LIMIT/ CIRCULATOR HIGH K LIMIT R ZR ZC K L LINE VOLTAGE OIL URNER RELAY OR GAS VALVE uilding Automation POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. CONTROL CASE MUST E CONNECTED TO EARTH GROUND. USE GROUNDING SCREW PROVIDED. IS /4 IN. TA TERMINAL. C C LINE VOLTAGE CIRCULATOR M880 Coercial Components Pneumatic

14 TH TR TH ZONE THERMOSTAT V804F TR TH TR TH ZONE THERMOSTAT V804F TR T LOW VOLTAGE THERMOSTAT T L84 G L (HOT) L TV T W K Z R L84G,L ZR G K L (HOT) L W K R K LOW LIMIT/ CIRCULATOR K R HIGH LIMIT K C C LINE VOLTAGE CIRCULATOR LOW LIMIT/ CIRCULATOR K HIGH LIMIT R ZC C 4 C LINE VOLTAGE OIL URNER RELAY OR GAS VALVE LINE VOLTAGE CIRCULATOR POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. POWERPILE CONTROL CASE MUST E CONNECTED TO EARTH GROUND. USE GROUNDING SCREW PROVIDED. IS /4 IN. TA TERMINAL. TH TH PP PP MILLIVOLTAGE GAS VALVE M884 4 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. UP TO TWO V804F ZONE VALVES CAN E POWERED WITH L84G,L. ADD ADDITIONAL TRANSFORMER FOR EVERY TWO OR LESS VALVES. CONTROL CASE MUST E CONNECTED TO EARTH GROUND. USE GROUNDING SCREW PROVIDED. IS /4 IN. TA TERMINAL. M795 TV K LOW VOLTAGE THERMOSTAT T Z L84E G L (HOT) L K W R LOW LIMIT/ CIRCULATOR HIGH LIMIT R K C C LINE VOLTAGE CIRCULATOR TR TH LOW VOLTAGE GAS VALVE (eg, VR800) POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. CONTROL CASE MUST E CONNECTED TO EARTH GROUND. USE GROUNDING SCREW PROVIDED. IS /4 IN. TA TERMINAL. M customer.honeywell.com

15 Dimensions, Approximate: 6 /8 in. high x 4 /8 in. wide x /6 in. deep (56 high x wide x 78 deep) Voltage: 0 Vac Maximum Ambient Temperature: 50 F at switches, 65 F at sensing element (66 C at switches, 9 C at sensing element.) Operating Range, High Limit: 0 F to 40 F (54 C to 6 C ) Operating Range, Low Limit: 0 F to 0 F (4 C to 04 C ) Maximum Operating Pressure: 00 psi on outside of iersion well, 00 psi on capsule if inserted directly. (78 kpa on outside of iersion well, 690 kpa on capsule if inserted directly.) Electrical Ratings Product Number L84A, C, G, L Line Voltage: Vac;.7 40 Vac 40 Vac L84* Line Voltage: Vac;.7 40 Vac 40 Vac L84E** Operating Humidity Range (% RH): 0 to 95% RH, non-condensing Canadian Standards Association: Certified: File No. LR60, Guide No. 400-E-O Underwriters Laboratories Inc. UL Listed (models with well): File No. MP466, Guide No. MPR; UL Component Recognized (models without well): File No. MP466, Guide No. MPR (burner AFL) (burner ALR) (circulator AFL) (circulator ALR) Line Voltage: Vac; Vac; 7.4 A. 40 Vac; Vac Vac Line Voltage: Vac; Vac; 7.4 A. 40 Vac; Vac Vac Line Voltage: Vac;.7 40 Vac Line Voltage: Vac;.7 40 Vac.7 40 Vac; Vac *L84 s burner rating is /4 to VCD. ** L84E s burner rating 4 Vac; 0 VA total load (-, TV-Z). Product Number L84A007 L84A05 Application High Limit Protection, Low Limit and Circulation Control High Limit Protection, Low Limit and Circulation Control Differential Temperature Insulation Depth.7 40 Vac; Vac (F) (inch) () Mounting Includes High limit: 0 F fixed; low / in. 8 Vertical in. insertion limit: 0-5 F well High limit: 0 F fixed; low limit: 0-5 F * L8409 Triple Aquastat Relay with High limit High limit: 0 F fixed; low limit: 0-5 F L84C00 Triple Aquastat Relay with High limit High limit: 0 F fixed; low limit: 0-5 F L84C0 High Limit Protection, Low Limit and Circulation Control High limit: 0 F fixed; low limit: 0-5 F * L84E06 Triple Aquastat Relay with High limit High limit: 0 F fixed; low limit: 0-5 F L84G00 Triple Aquastat Relay with High limit High limit: 0 F fixed; low limit: 0-5 F L84L0 Triple Aquastat Relay with High limit High limit: 0 F fixed; low limit: 0-5 F * TRADELINE models SUPER TRADELINE models in. 76 Vertical in. insertion well and ground screw. Vertical / in. to in. less well. 8 to 76 less well Vertical Vertical Indoor Air Quality Combustion Hydronic uilding Automation Coercial Components Pneumatic

16 L848 Aquastat Relay Iersion-type controllers that combine high limit protection with switching relay control of burner and circulator motors. High limit opens burner circuit only. Include transformer and accessory terminals for adding a remote low limit controller. Case available for horizontal or vertical mounting. Requires a 4 Vac thermostat with heat anticipator set at 0.A. TRADELINE models include well adapter, tube of heat conductive compound and range stops. Dimensions in inches (millimeters) Dimensions, Approximate: 4 5/6 in. high x 6 /8 in. wide x /8 in. deep (0 high x 56 wide x 79 deep) Anticipator Setting: 0. A Voltage: 0 Vac Frequency: 60 Hz Electrical Connections: Quick-Connect / Screw Maximum Ambient Temperature: 50 F with. A 4 V load; 77 F with.4 A 4 V load (66 C with. A 4 V load; 5 C with.4 A 4 V load) Setpoint Temperature Range: 40 F (6 C) Operating Range, High Limit: 0 F to 40 F (54 C to 6 C) Maximum Operating Pressure: Iersion Well: 55 psi (Iersion Well: 757 kpa) Operating Humidity Range (% RH): 0 to 95% RH, non-condensing Canadian Standards Association: Certified: File No. LR60, Guide No. 400-E-O Underwriters Laboratories Inc. UL Listed: File No. MP466, Vol., Sec., Guide No. MPR. 9 customer.honeywell.com

17 4 5 R L6006 LOW LIMIT CONTROLLER MILLIVOLTAGE POWERPILE GAS VALVE G L L PP PP W TH TH K TP 5 THTR L L (HOT) LOW VOLTAGE GAS VALVE (eg, VR800) L848J POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. REMOVE Z-W JUMPER IF SERIES 60 LOW LIMIT IS USED. WIRE LOW LIMIT CONTROLLER OR ZONE VALVES AS SHOWN. USE WITH 4V (-) CIRCUIT ONLY. FOR 4V URNER, WIRE - AND USE JUMPER Z-W AND TP-Z. FOR POWERPILE (MILLIVOLTAGE) GAS VALVES, REMOVE JUMPER TP-Z AND WIRE URNER -. JUMPER Z-W REMAINS IN POSITION. CONTROL CASE MUST E CONNECTED TO EARTH GROUND. USE GROUNDING SCREW PROVIDED. IS /4 IN. TA TERMINAL. TR TV TP Z W T K TV R TH W Z 4V THERMOSTAT T HIGH LIMIT C L R C L AUTO MANUAL SWITCH G 4 C C 5 L848J CIRCULATOR K M79 G L L R W L6006 LOW LIMIT CONTROLLER L848A L L HOT G L L T T R T T C C K CIRCULATOR JUMPER C HIGH LIMIT K K 4V THERMOSTAT L848A TO LINE VOLTAGE OIL URNER RELAY OR GAS VALVE C POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. REMOVE JUMPER WHEN ADDING L6006 LOW LIMIT CONTROLLER. CONTROL CASE MUST E CONNECTED TO EARTH GROUND. 4 USE GROUNDING SCREW PROVIDED. IS /4 IN. TA TERMINAL. M84A 4 R 4 Indoor Air Quality Combustion Hydronic uilding Automation Coercial Components Pneumatic

18 D89/M A CALE 4 L848E65 4 TV W T 4 VAC THERMOSTAT K Z FUSE HIGH LIMIT CONTROLLER R K 5 C C POLARIZED 4-PRONG MALE MOLEX PLUG AND 4-PRONG FEMALE MATING PLUG ON CALE 6-PRONG FEMALE MOLEX RECEPTALE IN L848E AND 5-PRONG MALE MOLEX PLUG ON CALE K L 5 L CIRCULATOR POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. S8600 L (HOT) L REMOVE PLUG-IN THAT JUMPERS PINS AND WHEN USING VENT DAMPER. AFTER VENT DAMPER IS PLUGGED INTO L848E65, FUSE LOWS WHEN THERMOSTAT FIRST CLOSES. AFTER FUSE LOWS, L848E65 OPERATES ONLY WHEN VENT DAMPER IS CONNECTED. 4V GND 4V 4 SEE VENT DAMPER PRODUCT SPECIFICATIONS FOR INTERNAL SCHEMATICS. M76C 5 IS /4 IN. TA TERMINAL. Electrical Ratings Product Number (ALR) (AFL) (burner AFL) (burner ALR) L848A07 Line Voltage: Vac;.7 40 Vac L848E to Vdc L848E to 40 Vac; 0 40 Vac; 0 Vac Low Voltage: 0.8 A 4 Vac; Line Voltage: Vac;.7 40 Vac Low Voltage: 0.8 A 4 Va; Line Voltage: Vac;.7 40 Vac L848J Vac7.4 0 Vac Product Number Application Differential Capillary Temperature Length Line Voltage: Vac;.7 40 Vac Line Voltage: Vac;.7 40 Vac Line Voltage: Vac;.7 40 Vac. 40 Vac Vac Insulation Depth (F) (inch) () (inch) () * L848A07 High Limit 8 F fixed 4 / in. 4 / in. to in. less well * L848E65 High Limit 5 F fixed 4 / in. 4 / in. to in. less well L848E99 High Limit 5 F fixed 4 / in. 4 / in. to in. less well * L848J009 Aquastat Relay * TRADELINE models SUPER TRADELINE models 8 F fixed 4 / in. 4 / in. to in. less well 8 to 76 less well 8 to 76 less well 8 to 76 less well 8 to 76 less well (burner millivolt) 0.5 /4 to Vdc 0.5 /4 to Vdc 0.5 /4 to Vdc 0.5 /4 to Vdc (circulator AFL).7 40 Vac; Vac.7 40 Vac; Vac.7 40 Vac; Vac.7 40 Vac; Vac Switching Action Mounting Includes SPST: High Limit & Circulator SPST: High Limit & Circulator SPST: High Limit & Circulator SPST: High Limit & Circulator (circulator ALR). 40 Vac; Vac.7 40 Vac; Vac.7 40 Vac; Vac. 40 Vac; Vac Vertical Mount Molex plug for use with vent damper, includes heatconductive compound.molex plug for use with vent damper, includes heatconductive compound. Vertical Mount 50 VA transformer and heat conductive compound. or Vertical 94 customer.honeywell.com

19 L74 Oil Electronic Aquastat Controller Indoor Air Quality Dimensions, Approximate: 7 /8 in. high x 4 /4 in. wide x 5/8 in. deep (8 high x 09 wide x 67 deep) Maximum Power Consumption: 000 VA Voltage: 0 Vac Frequency: 60 Hz Maximum Ambient Temperature: 50 F (66 C) Minimum Ambient Temperature: -0 F (-9 C) Electrical Ratings Product Number Operating Range, High Limit: 0 F to 40 F (54 C to 6 C) Operating Range, Low Limit: 0 F to 0 F (4 C to 04 C) Operating Humidity Range (% RH): 0 to 95% RH, non-condensing Underwriters Laboratories Inc. Recognized (burner AFL) (burner ALR) (circulator AFL) (circulator ALR) L74U Vac 44.4 A inrush Vac 44.4 A inrush Combustion Hydronic Differential Temperature Product Number Application (F) L74U00 Oil Aquastat Controller High limit: 5-0 F ; low limit: 0-5 F Mounting Well mount, horizontal or vertical position, or flush mounted remote from the well. uilding Automation Coercial Components Pneumatic

20 R88 Combination Protectorelay and Hydronic Heating Controllers Iersion type Aquastat controller and oil burner primary control provides high limit and low limit/circulator control for oilfired hydronic heating systems. Use in intermittent ignition applications. Capable of zone control with zone valves. Circulator zone control with ZC and ZR terminals on R88D,E,H,J. Flame failure during the running cycle results in a 45 second attempt to restart. If unsuccessful, safety shutoff occurs, requiring manual reset before burner can be restarted. R88D,E,F mount directly on burner; R88H,J mount on 4 x 4 in. junction box and include 5 ft (.5 m) armored capillary with remote sensor. C554A Cadmium Sulfide Flame Detector and a 4 Vac thermostat required. Vertical or Mount Junction ox Mount Dimensions in inches (millimeters) Dimensions, Approximate: 7 /8 in. high x 5 /4 in. wide x 7/6 in. deep (8 high x wide x 87 deep.) Anticipator Setting: 0. A Electrical Ratings (ignition): 60 VA Electrical Ratings (burner AFL): Vac Electrical Ratings (burner ALR): 0 Vac Maximum Power Consumption: 9 W Voltage: 0 Vac Frequency: 60 Hz Timing Safety Switch: 45 sec Maximum Ambient Temperature: 50 F at element ( C at element) Operating Range, High Limit: 0 F to 40 F (54 C to 6 C) Operating Range, Low Limit: 0 F to 0 F (4 C to 04 C) Maximum Operating Pressure: 00 psi on iersion well; 00 psi direct iersion. (78 kpa on iersion well; 90 kpa direct iersion.) Operating Humidity Range (% RH): 0 to 95% RH, non-condensing Canadian Standards Association: Certified: File No. LR959- Underwriters Laboratories Inc. UL Listed: File No. listed: MP68, Vol.,4 (R88D,E,F), Vol. 7 (R88H,J), Sec.. 96 customer.honeywell.com

21 Product Number Application * R88D079 Use in an intermittent ignition application * R88D Use in an intermittent ignition application * R88H070 Use in an intermittent ignition application Aquastat Part Differential Temperature Insulation Depth (F) (inch) () Mounting Includes High limit: 0 F fixed; / in. 8 Vertical Auxiliary ZC and ZR terminals may be used to provide Low limit/circulator: circulator zone control through an R845A Switching 0 F to 5 F Relay. Heat-conductive compound and vertical case. High limit: 0 F fixed; Low limit/circulator: 0 F to 5 F High limit: 0 F fixed; Low limit/circulator: 0 F to 5 F * TRADELINE models SUPER TRADELINE models Single and Multifunction Aquastat Parts / in. 8 Auxiliary ZC and ZR terminals may be used to provide circulator zone control through an R845A Switching Relay. Heat-conductive compound and vertical case. / in. 8 Junction box mount Auxiliary ZC and ZR terminals may be used to provide circulator zone control through an R845A Switching Relay. Heat-conductive compound and horizontal case. Product Number Description Used With 4074EUS ag Assembly containing Quick Connect to Screw Terminal for L84 or L848 L848L84 Product Number Type Description 7 Clip Clip, / inch well 0650 Heat Conductive Grease 98799Z Sensor Outdoor or Supply sensor with 4 in. lead for AQ475, AQ675 or AQ Sensor Sensor Assembly ulb Diameter (inch) Lead Length Leadwire (inch) Ending Leadwire Temperature /8 in. 4 in. Strip & Retain 5 C Picture Indoor Air Quality Combustion Hydronic uilding Automation Coercial Components Pneumatic

22 Well Assemblies Well Assemblies Product Insertion Number Description Materials Length 7A 7AA 7 7E 7L 7M 869A 870A 87A Copper. ulb size: in. (0 x 76 ). Well size: in. (76 ) insertion, / in.. Includes mounting clamp. Well clamp assembly with clamp capillary 7 () screws and nuts 6056 Copper. ulb size: in. (0 x 76 ). Well size: in. (76 ) insertion, / in. (8 ) insulation, /4 in.. Includes mounting clamp. Stainless steel. ulb size: in. (0 x 76 ). Well size: in. (76 ) insertion, / in. (8 ) insulation, / in. ( ). Includes mounting clamp. Copper. ulb size: in. (0 x 76 ). Well size: in. (76 ) insertion, in. (76 ) insulation, / in.. Includes mounting clamp. Copper. ulb size: in. (0 x 76 ). Well size: in. (76 ) insertion, / in. (8 ) insulation, /4 in.. Includes mounting clamp. Copper. ulb size: in. (0 x 76 ). Well size: in. (76 ) insertion, / in. (8 ) insulation, / in.. Copper. ulb size: in. (0 x 76 ). Well size: in. (76 ) insertion, / in. (8 ) insulation, /4 in.. Copper. ulb size: in. (0 x 76 ). Well size: in. (76 ) insertion, in. (76 ) insulation, /4 in.. Shell (internal diameter) Spud Thread Size Copper / in. /8 in. / in. x 4 / in. /8 in. / in. x 4 Copper / in. /8 in. /4 in. x 4 Stainless Steel / in. /8 in. / in. x 4 Copper in. /8 in. / in. x 4 Copper in. /8 in. /4 in. x 4 Copper / in. /8 in. / in. x 4 Copper / in. /8 in. /4 in. x 4 Copper in. /8 in. /4 in. x 4 Includes 7 Mounting Clamp 7 Mounting Clamp, Spud Set screw for armored capillary, Plug, and Nut. 7 Mounting Clamp 7 Mounting Clamp 7 Mounting Clamp 7 Mounting Clamp 5975 Well Clamp Used With L408; L4006 Picture 98 customer.honeywell.com

23 Well Assemblies Product Insertion Number Description Materials Length 87A 499AA 84/ 00 Copper. ulb size: in. (0 x 76 ). Well size: in. (76 ) insertion, in. (76 ) insulation, / in. Copper. ulb size: /8 in. (0 ). Well size: in. (76 ) insertion, / in. (8 ) insulation, /4 in.. Includes set screw with spud for armored capillary with plug. ulb size: in. (0 x 76 ). Well size: in. (76 ) insertion, /4 in. Shell Spud (internal Thread diameter) Size Includes Copper in. /8 in. / in. Copper / in. /8 in. /4 in. x 4 Set screw in spud for armored capillary with plug Used With Picture Indoor Air Quality Combustion Hydronic uilding Automation Coercial Components Pneumatic

24 Integrated Furnace Universal Hot Surface Ignition Integrated Furnace Control Description: Universal single stage heating and cooling The S900U000 can be used with conventional thermostats as well as the EnviraCOM enabled VisionPRO IAQ and FocusPRO. The S900U000 Universal Integrated Furnace Control is intended for residential natural or liquid propane fueled furnaces only. The S900U000 EnviraCOM counications capability allows its use in twinning applications and enables counication with local and remote diagnostic devices such as the QuickLook hand held device (QuickLook 7), EnviraLINK web-based application and the W875D Telephone Access Module (TAM). Main burner ignition using a 0V hot surface igniter. Flame rectification circuit to monitor flame presence. Monitoring of system pressure switch, high limit, and rollout functions. Appliance operation/safety requirements controlled via microprocessor. Control of a standard induction-type circulating fan motor (based on appliance requirements), in response to a conventional low voltage or EnviraCOM thermostat. LED system status, performance and diagnostic indication. Wire harnesses provided for simple replacement of most IFCs and integration with most heating and cooling appliances. Twinning capability. EnviraCOM counication capability to enable local and/or remote system status, diagnostics, troubleshooting, and HVAC system control. Product Number Frequency Operating Temperature (F) Operating Temperature (C) PrePurge PostPurge S900U Hz -40F to 75F -40C to 79C 0 sec. 5 sec. 00 customer.honeywell.com

25 AQUATROL Zoning System AQ50 Electronic Relay oiler Control Panel for Hydronic Zoning System The AQ50 family of AQUATROL oiler provides simplified, energy-efficient control of single, residential hydronic heating systems. The AQ50 easily converts a single zone heating system into a room-by-room comfort control system, or upgrades a basic, relay-logic zoning system to intelligent Zone of Greatest Demand control for increased energy efficiency with reduced boiler cycling. AQ50 boiler controls can ensure ample supply of hot water for both space heating and priority generation of domestic hot water for bathing, dishes and laundry. -stage zoning. Zoning Control for up to 4 zones as shipped; can be expanded to a total of 6 zones with AQ55 or AQ57 expansion zoning panels and up to 64 zones when used with AQ54 Add-A-Temp panels. Line or low-voltage output for zoning equipment (pumps or valves). Zone synchronization through Zone or Greatest Demand control. Domestic hot water priority and priority override protection. oiler short cycling protection. oiler post purge. Freeze protection. Pump/valve exercise. Automated test feature for quick start-up and simplified troubleshooting. Integral 8 VA transformer with self-resetting electronic fuse. CSA C/US Certified to CSA and UL Standards, File No. LR7600. Application: oiler control for hydronic zoning system Dimensions, Approximate: in. wide x 8 in. high x /8 in. deep ( cm wide x 0. cm high x 8.5 cm deep) Power Supply: 0V/60Hz User Interface (Setting, Prograing): DIP Switches Electrical Connections (Line Voltage): Wire-clamp screw terminals, Maximum x 4 AWG each on line voltage terminals Control and Zoning Panel Temperature Rating: F to 0 F (0 C to 55 C) Thermostat Compatibility: AQ000 Series -wire counicating thermostats Zone Module Thermostat input: Low voltage, Class II, -wire polarityinsensitive, digital counicating with power link to AQ000 series thermostat. oiler Heat Post Purge: Off, 0 seconds to 0 minutes (factory default is 0 seconds) oiler (T-T) Output Rating: 4Vac, 0.5A, VA oiler Differential: F to 4F (C to C), or Auto (minimum minutes on time) DHW Pump/Valve Output Rating: 0 Vac/50 Vac 5A, /HP DHW Demand Input: External dry connection only Product Number AQ504 AQ5044 Type of Zoning Devices Controlled Pump or -wire valve (line voltage) Zone valve with end switches Number of Zones Controlled Pump/Valve exercise: 0 seconds per weeks of space heating inactivity Auxiliary Pump Output Rating: Dry contact output, 0 Vac/50 Vac 5A, / HP Zone Output Contact Rating: 0 Vac/50 Vac, 5A, / HP ZR-ZC Contact Rating: 0 to 40 Vac, / HP Sensor Temperature Rating: -58 F to +0 F (-50 C to +0 C) Supply/Return Sensor: Lead Length: 0 ft. (050 ). 0 kohm NTC thermistor at 5 C (77 F) ± 0.5F (±0.C) up to 500 ft (50 M) using 8 AWG or larger wire, beta=89. Heat Demand (Thermostat R-W) Input: External dry connection only - Counication us Terminals: Low voltage, Class II, -wire polarity-insensitive, digital counicating link to other Control or Zoning modules. R-C Input (on Control and Zoning Modules): 4 Vac Class II (input on Control and Zoning Modules) R-C Output (on transformer): 8 VA, 4 Vac Class II Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Weight: 4.9 lbs (. kg) Canadian Standards Association: Certified, File No. LR7600 oiler Pump (C-C) Output Rating Replacement Parts 4 (Counicating) 0 Vac/50 Vac 5A, /HP AQ5000 boiler control module; AQC supply/return sensor; AQ0X8 4 Vac 8 VA transformer; AQ554P 4-zone pump expansion module 4 (Counicating) 0 Vac/50 Vac 5A, /HP AQ5000 boiler control module; AQ574V4 4-zone valve with end switch expansion module; AQC supply/return sensor; AQ0X8 4 Vac 8 VA transformer Indoor Air Quality Combustion Hydronic uilding Automation Coercial Components Pneumatic

26 AQUATROL Zoning System AQ5A Prograable Relay Control Panel for Hydronic Zoning System The AQ5A family of AQUATROL oiler provides simplified, energy-efficient control of single-, residential hydronic heating systems. The AQ5A easily converts a single zone heating system into a room-by-room comfort control system, or upgrades a basic, relay-logic zoning system to intelligent Zone of Greatest Demand control for increased energy efficiency with reduced boiler cycling. AQ5A boiler controls can ensure ample supply of hot water for both space heating and priority generation of domestic hot water for bathing, dishes and laundry. Application: oiler control for hydronic zoning system Dimensions, Approximate: 6 / in. wide x 8 in. high x /8 in. deep (4 cm wide x 0. cm high x 8.5 cm deep) Power Supply: 0V/60Hz User Interface (Setting, Prograing): LCD Display and a 7 button Key Pad Electrical Connections (Line Voltage): Wire-clamp screw terminals, Maximum x 4 AWG each on line voltage terminals Control and Zoning Panel Temperature Rating: F to 0 F (0 C to 55 C) Thermostat Compatibility: AQ000 Series -wire counicating thermostats Zone Module Thermostat input: Low voltage, Class II, -wire polarityinsensitive, digital counicating with power link to AQ000 series thermostat. Setback Program: 7 day, up to setback periods/day. oiler Heat Post Purge: Off, 0 seconds to 0 minutes (factory default is 0 seconds) oiler (T-T) Output Rating: 4Vac, 0.5A, VA oiler Differential: F to 4F (C to C), or Auto (minimum minutes on time) oiler Pump (C-C) Output Rating: 0 Vac/50 Vac 5A, /HP DHW Pump/Valve Output Rating: 0 Vac/50 Vac 5A, /HP DHW Demand Input: External dry connection only Use with AQ000 -wire polarity insensitive counicating thermostats. Displays outdoor on all AQ000 Series thermostats when used with an AQC0 outdoor sensor (included). Intuitive prograing interface and armchair prograing (can be prograed at your desk and taken to the job site ready-to-install ) Customizable control settings and schedules allow for greater level of control and comfort. Central Zoning Control for up to 4 zones as shipped; can be expanded to a total of 6 zones with AQ55 or AQ57 expansion zoning panels, and up to 64 zones when used with AQ54 Add-a- Temperature panels. Zone synchronization through Zone of Greatest Demand control. Domestic hot water priority and priority override protection. Line or low-voltage output for zoning equipment (pumps or valves). oiler short cycling protection. oiler post purge. Freeze protection. Pump/valve exercise. Automated test and purge feature for quick start-up and simplified troubleshooting. Integral 8 VA transformer with self resetting electronic fuse. hour power supply (super-capacitor) to retain day and time settings during power outage. Non-volatile EPROM memory retains program settings during power outage. Pump/Valve exercise: 0 seconds per weeks of space heating inactivity Auxiliary Pump Output Rating: Dry contact output, 0 Vac/50 Vac 5A, / HP Auxiliary Low Voltage Output Rating: 4Vac, 0.5A, VA Auxiliary (Demand) Input: External dry connection only Zone Output Contact Rating: 0 Vac/50 Vac, 0.5A, VA Sensor Temperature Rating: -58 F to +0 F (-50 C to +0 C) Outdoor Sensor: Supply/Return Sensor: Lead Length: 0 ft. (050 ). 0 kohm NTC thermistor at 5 C (77 F) ± 0.5F (±0.C) up to 500 ft (50 M) using 8 AWG or larger wire, beta=89. Heat Demand (Thermostat R-W) Input: External dry connection only - Counication us Terminals: Low voltage, Class II, -wire polarity-insensitive, digital counicating link to other Control or Zoning modules. R-C Input (on Control and Zoning Modules): 4 Vac Class II (input on Control and Zoning Modules) R-C Output (on transformer): 8 VA, 4 Vac Class II Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Weight: 5.7 lbs (.6 kg) Canadian Standards Association: Certified, File No. LR7600 Product Number AQ5A4 AQ5A44 Type of Zoning Devices Controlled Pump or -wire valve (line voltage) Zone valve with end switches Number of Zones Controlled Replacement Parts 4 (Counicating) AQ5A00 boiler control module; AQC supply/return sensor; AQC0 outdoor sensor; AQ0X8 4 Vac 8 VA transformer; AQ554P 4-zone pump expansion module 4 (Counicating) AQ5A00 boiler control module; AQ574V4 4-zone valve with end switch expansion module; AQC supply/return sensor; AQC0 outdoor sensor; AQ0X8 4 Vac 8 VA transformer 0 customer.honeywell.com

27 AQUATROL Zoning System AQ5 Electronic oiler Control Panel for Hydronic Zoning System The AQ5 family of AQUATROL oiler provides simplified, energy-efficient outdoor compensated control of single, residential hydronic heating systems. The AQ5 easily converts a single zone heating system into a room-by-room comfort control system, or upgrades a basic, relay-logic zoning system to intelligent Zone of Greatest Demand control with outdoor reset for increased energy efficiency with reduced boiler cycling. AQ5 boiler controls can ensure ample supply of hot water for both space heating and priority generation of domestic hot water for bathing, dishes and laundry. Displays outdoor on all thermostats when used with an AQC0 outdoor sensor (included). Application: oiler reset control for hydronic zoning system Power Supply: 0V/60Hz User Interface (Setting, Prograing): LCD Display and a 7 button Key Pad Electrical Connections (Line Voltage): Wire-clamp screw terminals, Maximum x 4 AWG each on line voltage terminals Control and Zoning Panel Temperature Rating: F to 0 F (0 C to 55 C) Thermostat Compatibility: AQ000 Series -wire counicating thermostats Setback Program: 7 day, up to setback periods/day. oiler Design Temperature: 80F to 0F (6C to 99C) oiler (Supply) Max. Control Temperature: OFF, 59F to 80F (OFF, 5C to 8C) oiler (Supply) Max. Control Temperature: (OFF, 0F to 5 F) OFF, 49C to 07 C oiler Heat Post Purge: Off, 0 seconds to 0 minutes (factory default is 0 seconds) oiler (T-T) Output Rating: 4Vac, 0.5A, VA oiler Differential: F to 4F (C to C), or Auto (minimum minutes on time) oiler Pump (C-C) Output Rating: 0 Vac/50 Vac 5A, /HP DHW Pump/Valve Output Rating: 0 Vac/50 Vac 5A, /HP DHW Demand Input: External dry connection only Outdoor Low Design Control Temperature: -60F to F (-5C to 0C) Return Minimum Control Temperature: 80 F to 80 F (7C to 8C) Product Number Type of Zoning Devices Controlled Number of Zones Controlled AQ50 Pump (Noncounicating) AQ54 Pump or - wire valve AQ544 Zone valve with end switch Dimensions, Approximate 4 6 / in. wide (Counicating) x 8 in. high x /8 in. deep 4 6 / in. wide (Counicating) x 8 in. high x /8 in. deep Intuitive prograing interface and armchair prograing (can be prograed at your desk and taken to the job site ready-to-install ) Customizable control settings and schedules allow for greater level of control and comfort. Central prograing of zone set points and setback. -stage zoning. Zoning Control for up to four zones as shipped; can be expanded to a total of 6 zones with AQ55 or AQ57 expansion zoning panels, and up to 64 zones by using AQ54 Add-a-Temperature expansion panels. Outdoor compensation (reset), or Load reset based on indoor feedback. Zone synchronization through Zone of Greatest Demand control. Domestic hot water priority and priority override protection. Line or low-voltage output for zoning equipment (pumps or valves). oiler short cycling protection. oiler post purge. Freeze protection. Pump/valve exercise. Automated test and purge feature for quick start-up and simplified troubleshooting. Integral 8 VA transformer with self resetting electronic fuse. hour power supply (super-capacitor) to retain day and time settings during power outage. Non-volatile EPROM memory retains program settings during power outage. Pump/Valve exercise: 0 seconds per weeks of space heating inactivity Auxiliary Pump Output Rating: Dry contact output, 0 Vac/50 Vac 5A, / HP Auxiliary Low Voltage Output Rating: 4Vac, 0.5A, VA Auxiliary (Demand) Input: External dry connection only WWSD (Warm Weather Shut Down) Temperature: Off, 5 F to 00 F (Off, C to 8 C) Sensor Temperature Rating: -58 F to +0 F (-50 C to +0 C) Supply/Return Sensor: Lead Length: 0 ft. (050 ). 0 kohm NTC thermistor at 5 C (77 F) ± 0.5F (±0.C) up to 500 ft (50 M) using 8 AWG or larger wire, beta=89. - Counication us Terminals: Low voltage, Class II, -wire polarity-insensitive, digital counicating link to other Control or Zoning modules. R-C Input (on Control and Zoning Modules): 4 Vac Class II (input on Control and Zoning Modules) R-C Output (on transformer): 8 VA, 4 Vac Class II Heat Demand (Thermostat R-W) Input: External dry connection only Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Weight: 4.9 lbs (. kg) Canadian Standards Association: Certified, File No. LR7600 Weight (inch) () (lb) (kg) Replacement Parts in. wide x cm wide x 4.9. AQ500 boiler reset module; 8 in. high x 0. cm high x lbs kg AQC supply/return sensor; /8 in. deep 8.5 cm deep AQC0 outdoor sensor; AQ0X8 4 Vac 8 VA transformer 4 cm wide x AQ500 boiler reset module; 0. cm high x lbs kg AQC supply/return sensor; 8.5 cm deep AQC0 outdoor sensor; AQ0X8 4 Vac 8 VA transformer; AQ554P 4-zone pump expansion module 4 cm wide x AQ500 boiler reset module; 0. cm high x lbs kg AQ574V4 4-zone valve with end switch expansion 8.5 cm deep module; AQC supply/return sensor; AQC0 outdoor sensor; AQ0X8 4 Vac 8 VA transformer Indoor Air Quality Combustion Hydronic uilding Automation Coercial Components Pneumatic

28 AQUATROL Zoning System AQ5 Universal Injection/Mixing oiler Control Panel for Hydronic Zoning System The AQ5 family of AQUATROL Universal Injection/Mixing oiler provides simplified, energy-efficient outdoor compensated control of single-, residential hydronic heating systems. The AQ5 easily converts a single zone heating system into a room-by-room comfort control system, or upgrades a basic, relay-logic zoning system to intelligent Zone of Greatest Demand control with outdoor reset for increased energy efficiency with reduced boiler cycling. AQ5 boiler controls can ensure ample supply of hot water for both space heating and priority generation of domestic hot water for bathing, dishes and laundry. one boiler loop and one mixed loop. Use of variable speed injection pump or motorized mixing valve for mixed loop control. Application: one boiler and one mixing (either variable speed injection or floating valve mixing) loop in a hydronic zoning system. Dimensions, Approximate: 6 / in. wide x 8 in. high x /8 in. deep (4 cm wide x 0. cm high x 8.5 cm deep) Power Supply: 0V/60Hz User Interface (Setting, Prograing): LCD Display and a 7 button Key Pad Electrical Connections (Line Voltage): Wire-clamp screw terminals, Maximum x 4 AWG each on line voltage terminals Control and Zoning Panel Temperature Rating: F to 0 F (0 C to 55 C) Thermostat Compatibility: AQ000 Series -wire counicating thermostats Setback Program: 7 day, up to setback periods/day. oiler Design Temperature: 80F to 0F (6C to 99C) oiler (Supply) Max. Control Temperature: OFF, 59F to 80F (OFF, 5C to 8C) oiler (Supply) Max. Control Temperature: (OFF, 0F to 5 F) OFF, 49C to 07 C oiler Heat Post Purge: Off, 0 seconds to 0 minutes (factory default is 0 seconds) oiler (T-T) Output Rating: 4Vac, 0.5A, VA oiler Differential: F to 4F (C to C), or Auto (minimum minutes on time) oiler Pump (C-C) Output Rating: 0 Vac 5A, /HP DHW Pump/Valve Output Rating: 0 Vac 5A, /HP DHW Demand Input: External dry connection only Outdoor Low Design Control Temperature: -60F to F (-5C to 0C) Return Minimum Control Temperature: 80 F to 80 F (7C to 8C) Variable Speed Injection Pump Output: Triac modulated; 0 Vac,.A, /6HP Pump/Valve exercise: 0 seconds per weeks of space heating inactivity Use with AQ000 -wire polarity insensitive counicating thermostats. Allows display of outdoor on all thermostats when used with an AQC0 outdoor sensor (included). Intuitive prograing interface and armchair prograing (can be prograed at your desk and taken to the job site ready-to-install ) Customizable control settings and schedules allow for greater level of control and comfort. Central set-back schedules available. -stage zoning. Zoning Control for up to four zones as shipped; can be expanded to a total of 6 zones with AQ55 or AQ57 expansion zoning panels, and up to 64 zones by using AQ54 Add-a-Temperature expansion panels. Outdoor compensation (reset), or Load reset based on indoor feedback. Zone synchronization through Zone of Greatest Demand control. Domestic hot water priority and priority override protection. Line or low-voltage output for zoning equipment (pumps or valves). oiler short cycling protection. oiler post purge. Freeze protection. Pump/valve exercise. oiler shock prevention from cold water returning to boiler. Automated test and purge feature for quick start-up and simplified troubleshooting. Integral 8 VA transformer with self resetting electronic fuse. 4 hours power supply (super capacitor) to retain day and time settings during power outage. Non-volatile EPROM memory retains program settings during power outage. Secondary Pump Output Rating: 0 Vac 5A, /HP Auxiliary Pump Output Rating: Dry contact output, 0 Vac/50 Vac 5A, / HP Auxiliary Low Voltage Output Rating: 4Vac, 0.5A, VA Auxiliary (Demand) Input: External dry connection only WWSD (Warm Weather Shut Down) Temperature: Off, 5 F to 00 F (Off, C to 8 C) Sensor Temperature Rating: -58 F to +0 F (-50 C to +0 C) Supply/Return Sensor: Lead Length: 0 ft. (050 ). 0 kohm NTC thermistor at 5 C (77 F) ± 0.5F (±0.C) up to 500 ft (50 M) using 8 AWG or larger wire, beta=89. Mixing Valve (Com,O,C) Output: 4Vac rated dry Secondary Loop Mixing (Supply) Design Temp Range: 70 F to 0 F ( C to 99 C) Secondary Loop Mixing (Supply) Max Control Temp Range: 80 F to 0 F (7 C to 99 C) Secondary Loop Return Min Control Temp Range: 80 F to 80 F (7 C to 8 C) Secondary Loop Mixing (Supply) Min Control Temp Range: 5 F to 50 F ( C to 66 C) Heat Demand (Thermostat R-W) Input: External dry connection only - Counication us Terminals: Low voltage, Class II, -wire polarity-insensitive, digital counicating link to other Control or Zoning modules. R-C Input (on Control and Zoning Modules): 4 Vac Class II (input on Control and Zoning Modules) R-C Output (on transformer): 8 VA, 4 Vac Class II Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Weight: 4.9 lbs (. kg) Canadian Standards Association: Certified, File No. LR customer.honeywell.com

29 AQUATROL Zoning System Product Number AQ54M AQ54M4 Type of Zoning Devices Controlled Pump or -wire valve (line voltage) AQ54 Add-a-Temperature Injection/Mixing Expansion Control Panel for Hydronic Zoning System The AQ54 Add-a-Temperature Expansion Control is used in conjunction with AQ50, AQ5A, AQ5 and AQ5 Control panels. It provides one additional loop control capability for the AQ000 control panel it is connected to and expands the total network capacity by up to 6 zones when used with AQ55 and/or AQ57 zoning panels. Acts as an add-on control panel to the Main (AQ50, AQ5A, AQ5, AQ5) Control panel. Allows each of the 6 zones connected to it to be assigned to the primary or secondary loop. Up to AQ54 panels can be added to the same hydronic system controlled by the same Main Control panel. Displays outdoor on all thermostats when used with an AQC0 outdoor sensor (not included). Mixed loop is controlled by a variable speed injection pump or motorized mixing valve. Intuitive prograing interface and armchair prograing (can be prograed at your desk and taken to the job site ready-to-install ) Customizable mixing control settings allow for greater level of control and comfort. Zone synchronization through Zone of Greatest Demand control. Integral 8 VA transformer with self resetting electronic fuse. Application: Expanded zone control and mixed loop control in a hydronic zoning system. Mixed loop target is reset by either outdoor or calculated system load based on indoor feedback. Mixing is target controlled by a variable speed injection pump or motorized mixing valve. Dimensions, Approximate: 9 / in. wide x 8 in. high x /8 in. deep (4 cm wide x 0. cm high x 8.5 cm deep) Power Supply: 0V/60Hz Electrical Connections (Line Voltage): Wire-clamp screw terminals, Maximum x 4 AWG each on line voltage terminals Control and Zoning Panel Temperature Rating: F to 0 F (0 C to 55 C) Thermostat Compatibility: AQ000 Series -wire counicating thermostats Variable Speed Injection Pump Output: Triac modulated; 0 Vac,.A, /6HP Secondary Pump Output Rating: 0 Vac 5A, /HP Auxiliary Pump Output Rating: Dry contact output, 0 Vac/50 Vac 5A, / HP Sensor Temperature Rating: -58 F to +0 F (-50 C to +0 C) Product Number Zone valve with end switches Number of Zones Weight Controlled (lb) (kg) Replacement Parts 4 (Counicating) 6.0 lbs.7 kg AQ50M0 universal injection/mixing boiler reset module; AQC supply/return sensor; AQC0 outdoor sensor; AQ0X8 4 Vac 8 VA transformer; AQ554P 4-zone pump expansion module 4 (Counicating) 6.0 lbs.7 kg AQ50M0 universal injection/mixing boiler reset module; AQ574V4 4-zone valve with end switch expansion module; AQC supply/return sensor; AQC0 outdoor sensor; AQ0X8 4 Vac 8 VA transformer Mixing Valve (Com,O,C) Output Replacement Parts AQ54E0 4 Vac rated dry AQC supply/return sensor for mixed loop. AQ540E0 Add-A-Temperature expansion control module AQ0X8 4 Vac 8 VA transformer Secondary Loop Mixing (Supply) Design Temp Range: 70 F to 0 F ( C to 99 C) Secondary Loop Mixing (Supply) Max Control Temp Range: 80 F to 0 F (7 C to 99 C) Secondary Loop Return Min Control Temp Range: 80 F to 80 F (7 C to 8 C) Secondary Loop Mixing (Supply) Min Control Temp Range: 5 F to 50 F ( C to 66 C) - Counication us Terminals: Low voltage, Class II, -wire polarity-insensitive, digital counicating link to other Control or Zoning modules. R-C Input (on Control and Zoning Modules): 4 Vac Class II (input on Control and Zoning Modules) R-C Output (on transformer): 8 VA, 4 Vac Class II Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Weight:.9 lbs (.8 kg) Canadian Standards Association: Certified, File No. LR7600 User Interface (Setting, Prograing) LCD Display and a button Key Pad Indoor Air Quality Combustion Hydronic uilding Automation Coercial Components Pneumatic

30 AQUATROL Zoning System AQ55 and AQ57 Zoning Expansion Panel for Hydronic Zoning System The AQ55 and AQ57 family of AQUATROL Expansion Zoning panels work with AQ000 oiler Control Panels and AQ000 Counicating Thermostat to control up to 4 space heating zones (or 8, for the AQ558PX Panel). Can be combined with additional expansion zoning panels and an AQ000 control panel for a total of 6 space heating zones. Application: Zoning control for hydronic zoning system Dimensions, Approximate: 9 / in. wide x 8 in. high x /8 in. deep (4 cm wide x 0. cm high x 8.5 cm deep) User Interface (Setting, Prograing): DIP Switches Electrical Connections (Line Voltage): Wire-clamp screw terminals, Maximum x 4 AWG each on line voltage terminals Control and Zoning Panel Temperature Rating: F to 0 F (0 C to 55 C) Thermostat Compatibility: AQ000 Series -wire counicating thermostats Zone Module Thermostat input: Low voltage, Class II, -wire polarityinsensitive, digital counicating with power link to AQ000 series thermostat. Product Number Type of Zoning Devices Controlled Number of Zones Controlled AQ57 for zoning with zone valves with end switches AQ55 for zoning with pumps or zone valves without end switches. Allows zone synchronization through Zone of Greatest Demand control. Auto test function to test zones at system start up. It allows for operator controlled testing of zones; includes pause/restart capability. LED lights for easy diagnostic of zone operation. Allows zoning with either Normally Open or Normally Closed zone valves. Adjacent zoning panels can operate different zone equipment - one panel may control 4 pumps while another may control 4 zone valves. Easily switch from zone valves to pumps with same zoning module - just flip one DIP switch. Ensure correct voltage is applied (0 Vac for pumps, 4 Vac for valves) R-C transformer and - data bus terminal connections and network counication for easy expansion. Zones can be set to energize a parallel group pump via Aux Out dry on main control panel (AQ50, AQ5A, AQ5, AQ5) or expansion control panel (AQ54). 8 VA Transformer with self resetting electronic fuse. Zone Output Contact Rating: 0 Vac/50 Vac, 5A, / HP - Counication us Terminals: Low voltage, Class II, -wire polarity-insensitive, digital counicating link to other Control or Zoning modules. R-C Input (on Control and Zoning Modules): 4 Vac Class II (input on Control and Zoning Modules) Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Weight:. lbs ( kg) Canadian Standards Association: Certified, File No. LR7600 Weight Replacement Parts AQ554PX Pump or -wire valve (line voltage) 4 (Counicating). lbs kg AQ554P 4-zone pump expansion module AQ554V -wire valve (4 Vac) 4 (Counicating).9 lbs.8 kg AQ0X8 4 Vac 8 VA transformer; AQ554P 4-zone pump expansion module AQ558PX Pump or -wire valve (line voltage) 8 (Counicating).6 lbs. kg AQ554P 4-zone pump expansion module AQ574V4 Zone valve with end switch (4 Vac) 4 (Counicating).9 lbs.8 kg AQ574V4 4-zone pump expansion module; AQ0X8 4 Vac 8 VA transformer (lb) (kg) 06 customer.honeywell.com

31 AQ000 Series Replacement Control Modules AQ50 Replacement modules for the AQ000 controls Electrical Connections (Line Voltage): Wire-clamp screw terminals, Maximum x 4 AWG each on line voltage terminals Product Number Type of Zoning Devices Controlled AQ000 Series Replacement Control Module Replacement module for the AQ000 controls AQ5A, AQ5, AQ5 Mixing Valve (Com,O,C) Output AQ5A00 Loop pump 7 /8 in. wide x / in. high x 4 /4 in. deep AQ5000 Loop pump / in. wide x / in. high x 4 /4 in. wide AQ500 Loop pump 7 /8 in. wide x / in. high x 4 /4 in. deep AQ50M0 Loop pump 4Vac rated dry Product Number Type of Zoning Devices Controlled AQUATROL Zoning System Control and Zoning Panel Temperature Rating: F to 0 F (0 C to 55 C) oiler Heat Post Purge: Off, 0 seconds to 0 minutes (factory default is 0 seconds) oiler (T-T) Output Rating: 4Vac, 0.5A, VA oiler Differential: F to 4F (C to C), or Auto (minimum minutes on time) DHW Demand Input: External dry connection only Pump/Valve exercise: 0 seconds per weeks of space heating inactivity Heat Demand (Thermostat R-W) Input: External dry connection only - Counication us Terminals: Low voltage, Class II, -wire polarity-insensitive, digital counicating link to other Control or Zoning modules. R-C Input (on Control and Zoning Modules): 4 Vac Class II (input on Control and Zoning Modules) Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Weight: 0.5 lbs (0. kg) Canadian Standards Association: Certified, File No. LR7600 Dimensions, Approximate Weight User Interface (Setting, (inch) () (lb) (kg) Prograing) 7 /8 in. wide x / in. high x 4 /4 in. deep Mixing Valve (Com,O,C) Output 8 cm wide x 94 cm high x 0.09 cm deep 9 cm wide x 94 cm high x 0.09 cm deep 8 cm wide x 94 cm high x 0.09 cm deep 8 cm wide x 94 cm high x 0.09 cm deep.0 lbs 0.5 kg LCD Display and a 7 button Key Pad 0.5 lbs 0. kg DIP Switches.0 lbs 0.5 kg LCD Display and a 7 button Key Pad Dimensions, Approximate: / in. wide x / in. high x 4 /4 in. deep (9 cm wide x 94 cm high x 0.09 cm deep) Electrical Connections (Line Voltage): Wire-clamp screw terminals, Maximum x 4 AWG each on line voltage terminals Control and Zoning Panel Temperature Rating: F to 0 F (0 C to 55 C) Pump/Valve exercise: 0 seconds per weeks of space heating inactivity - Counication us Terminals: Low voltage, Class II, -wire polarity-insensitive, digital counicating link to other Control or Zoning modules. R-C Input (on Control and Zoning Modules): 4 Vac Class II (input on Control and Zoning Modules) Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Weight: 0.5 lbs (0. kg) Canadian Standards Association: Certified, File No. LR7600 Weight.0 lbs 0.5 kg LCD Display and a 7 button Key Pad User Interface (Setting, Prograing) AQ540E0 Loop pump 4Vac rated dry 0.7 lbs 0. kg LCD Display and a button Key Pad (lb) (kg) Indoor Air Quality Combustion Hydronic uilding Automation Coercial Components Pneumatic

Product Number L4006A1017 L4006A1132 L4006A1967 L4006A2007 L4006B1007 L4006B1155 L4006B1163 3/4 (19) L4006H1004

Product Number L4006A1017 L4006A1132 L4006A1967 L4006A2007 L4006B1007 L4006B1155 L4006B1163 3/4 (19) L4006H1004 L4006; L6006 Aquastat Controller Aquastat Controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature

More information

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08 16/05/08 Aquatrol Indoor/Outdoor Control B3 Adjustable settings for boiler maximum temperature, boiler minimum temperature and outdoor low (design) temperature Selectable Warm Weather Shut Down (WWSD)

More information

AQ252 Universal Injection/Mixing Boiler Reset Control Panels

AQ252 Universal Injection/Mixing Boiler Reset Control Panels AQ252 Universal Injection/Mixing Boiler Reset Control Panels FEATURES PRODUCT DATA PRODUCT DESCRIPTION The AQ252 family of AQUATROL Universal Injection/Mixing Boiler Reset Controls provides simplified,

More information

AQ250 Series Hydronic Control Panels

AQ250 Series Hydronic Control Panels AQ50 Series Hydronic Control Panels PRODUCT DATA Need new photo of AQ50 PRODUCT DESCRIPTION The AQ50 easily converts a single-zone heating system into a room-by-room comfort control system, or upgrades

More information

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252 AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252 USER OPERATION AND MAINTENANCE WARNING Risk of electrical shock. Can cause severe injury, property damage or death. Only

More information

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers Electronic Pool and Spa Controllers The L8005A,B and LS8005A,C,D Electronic Pool and Spa Controllers are used in pool, spa, and hot tub applications to control water temperature. Remote Potentiometer L8005A,B

More information

Features & Benefits. Description. Example of LCD display screen. Functionality. Ordering Information: Model 7600 Boiler Control

Features & Benefits. Description. Example of LCD display screen. Functionality. Ordering Information: Model 7600 Boiler Control Model 7600 Boiler Control PARTS & ACCESSORIES Features & Benefits Beckett HeatManager TM dynamic temperature reset Cycle history diagnostic information Reduce inventory through universal design Backlit

More information

AQ255 and AQ257 Series Expansion Zoning Panels

AQ255 and AQ257 Series Expansion Zoning Panels AQ55 and AQ57 Series Expansion Zoning Panels PRODUCT DATA AQ574B AQ558B FEATURES The AQ55/AQ57 Series Expansion Zoning Panels have the following features: Availability of 4 Expansion Zoning Panels. Zone

More information

R8182D,E,F,H,J Combination Protectorelay Primary Control and Aquastat Controller

R8182D,E,F,H,J Combination Protectorelay Primary Control and Aquastat Controller R88D,E,F,H,J Combination Protectorelay Primary Control and Aquastat Controller APPLICAION he R88 combines a Protectorelay primary control and immersion type Aquastat controller in one unit for use in oil-fired,

More information

Table of Contents. Part Number Index SANDYS INDUSTRIAL GLASS WHEELER A

Table of Contents. Part Number Index SANDYS INDUSTRIAL GLASS WHEELER A Table of Contents Part Number Index MANUFACTURER Page MANUFACTURER Page 1 1271A 1271B -211-B15 182EA 2 220736B 5 5/8X10RL 5/8X12RL 5/8X18RL 5/8X24RL 5/8X36RL 5/8X48HDRL 5/8X60RL 6 CONBRACO 6012 WHEELER

More information

Instruction manual. WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules

Instruction manual. WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules Instruction manual WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules This manual must only be used by a qualified heating installer/service technician.

More information

Commercial/Industrial Combustion Control Level Three Announcement

Commercial/Industrial Combustion Control Level Three Announcement Commercial/Industrial Combustion Control Level Three Announcement SUBJECT: C6097 requiring venting Model Numbers Affected: C6097A and B Ref. Number L3-08-006 Issue Date 12/9/08 Author P.Yuen/L.Ziller Date

More information

Aquatrol. AQ2000 Series. Electronic Controls for Residential Hydronic Heating. Simple. Powerful. Affordable.

Aquatrol. AQ2000 Series. Electronic Controls for Residential Hydronic Heating. Simple. Powerful. Affordable. Aquatrol AQ2000 Series Electronic Controls f Residential Hydronic Heating Simple. Powerful. Affdable. Contract Install Photos Other products out there that I have dealt with are very difficult to set up,

More information

Inventory Management Guide

Inventory Management Guide EASTERN CANADA Inventory Management Guide Honeywell Residential Combustion is the industry leader in combustion controls for applications including warm air furnaces, boilers, commercial water heaters,

More information

7800 SERIES RM7888A Relay Module

7800 SERIES RM7888A Relay Module 7800 SERIES RM7888A Relay Module SPECIFICATION DATA FEATURES APPLICATION The Honeywell RM7888A Relay Module is a microprocessor-based integrated burner control for industrial process semi-automatically

More information

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001 SLATE Burner Control Module R8001B2001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Keep these instructions with the boiler at all times. BOYERTOWN FURNACE CO. PO Box 100 BOYERTOWN, PA 19512 1-610-369-1450 www.boyertownfurnace.com 5-25-12 2 Danger Warning Caution

More information

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module 7800 SERIES RM7840E,G,L,M; EC7840L Relay Module SPECIFICATION DATA Valve Proving features including: VPS test time When (Never, Before, After, Split or Both) FEATURES APPLICATION The Honeywell RM7840 is

More information

AQ475A Aquatrol Outdoor Temperature Compensator for Boilers

AQ475A Aquatrol Outdoor Temperature Compensator for Boilers A Aquatrol Temperature Compensator for s Features PRODUCT DATA Adjustable settings for boiler maximum temperature, boiler minimum temperature and outdoor low (design) temperature. Selectable Warm Weather

More information

ProRadiant Controls, Valves and Actuators

ProRadiant Controls, Valves and Actuators 214 Controls, Valves and Actuators Stock Controls, Valves and Actuators BASIC HEATING CONTROL Features: Modulating mixing valve control Supply temperature high limit Seasonal pump activation Boiler activation

More information

7800 SERIES EC7823/RM7823 Relay Module

7800 SERIES EC7823/RM7823 Relay Module 7800 SERIES EC7823/RM7823 Relay Module FEATURES SPECIFICATION DATA APPLICATION The Honeywell EC7823/RM7823 is a microprocessor based Flame Detector Relay that can be fitted with any 7800 SERIES amplifier

More information

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC Viega Zone Control Applications The Viega Zone Control is a wiring and switching center for individual and / or multi- room control. The Zone Control simplifies wiring between Thermostats and Powerheads.

More information

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules 7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules SPECIFICATION DATA FEATURES APPLICATION The Honeywell EC7895/RM7895/RM7896 is a microprocessor based integrated burner control for automatically

More information

L4064B2210 Fan and Limit Controller with 125 F fan on and 100 F fan off stops, 200 F high limit stop and 11 1/2 in. insertion

L4064B2210 Fan and Limit Controller with 125 F fan on and 100 F fan off stops, 200 F high limit stop and 11 1/2 in. insertion HOME ABOUT US PRODUCTS NEWS & EVENTS SUPPORT & RESOURCES CONTACT US HELP VIEW QUOTE Product Search Buildings Homes Applications & Downloads Cross Reference Product Selection Tool Thermostats Whole House

More information

Outdoor Reset IQ Option Card, p/n

Outdoor Reset IQ Option Card, p/n Outdoor Reset IQ Option Card, p/n 102723-01 Instruction Sheet CONTENTS Application... 1 General... 2 How it Works... 3 Installation.... 5 Wiring... 7 User Interface... 10 Using IQ Option Panel Display...

More information

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001 SLATE Base Module R8001A1001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform can

More information

RA889A Switching Relay

RA889A Switching Relay Switching Relay FEATURES PRODUT DATA High load switching capability. Troubleshooting LED. Push-to-test button. Replaceable transformer fuse. Long-life D relay drive control technology. Relay for use with

More information

- Data Brochure Universal Reset Module 422

- Data Brochure Universal Reset Module 422 - Data Brochure Universal Reset Module 422 D 422 08/07 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in

More information

D896 Automatic Vent Damper

D896 Automatic Vent Damper D896 Automatic Vent Damper FEATURES PRODUCT DATA 4-wire plug receptacle. Includes wiring harness on select models to fit plug receptacle onto S86/S8600/S860/S860 /L748/L848 or Penn Baso G60 or G66. For

More information

7800 SERIES RM7888A Relay Module

7800 SERIES RM7888A Relay Module 7800 SERIES RM7888A Relay Module FEATURES SPECIFICATION DATA APPLICATION The Honeywell RM7888A Relay Module is a microprocessor-based integrated burner control for industrial process semi-automatically

More information

Smart ways to save energy IntelliCon INSTALLATION MANUAL

Smart ways to save energy IntelliCon INSTALLATION MANUAL Smart ways to save energy IntelliCon INSTALLATION MANUAL, LLC 516-676-0777 www.llc.com 3/6/2006 Air Conditioning General Instructions: General Wiring Instructions 2-1 2 Stage Air Cooled Air Conditioners

More information

T7079A,B Solid State Remote Temperature Controllers

T7079A,B Solid State Remote Temperature Controllers T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature

More information

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers T4031A,B,P; T6031A,B Refrigeration Temperature Controllers FEATURES PRODUCT DATA Wide control temperature range is suitable for controlling ducts, tanks, freezers, coolers, display cases. and defrost termination.

More information

Installation & Operation Manual

Installation & Operation Manual tekmarnet 2 House Control 402 Installation & Operation Manual D 402 09/10 HVAC Systems Replaces: 01/10 Introduction The House Control 402 is designed to operate as part of a complete hydronic heating system

More information

Temperature & Humidity Controllers

Temperature & Humidity Controllers Electromechanical Temperature Controls T631 Air witch Controller Air witch Controller with heavy-duty corrosion resistant steel case. uitable for lift motor rooms, farm storage areas etc. Line voltage

More information

Hydronic & HVAC Control Systems

Hydronic & HVAC Control Systems tekmar 218 Full Line Catalog Hydronic & HVAC Control Systems HVAC Multi-Staging Alternative Energy Zoning Snow Melting Setpoint tekmarcontrols.com tekmarcontrols.com Better Design, Better Control, Better

More information

Outdoor Reset IQ Option Card, p/n

Outdoor Reset IQ Option Card, p/n Outdoor Reset IQ Option Card, p/n 102723-01 Instruction Sheet CONTENTS Application... 1 General... 2 How it Works... 3 Installation.... 5 Wiring... 7 User Interface... 10 Using IQ Option Panel Display...

More information

7800 SERIES: EC7895A,C; RM7895A,B,C,D; RM7896A,B,C,D RM7897A,C and RM7898A Relay Modules

7800 SERIES: EC7895A,C; RM7895A,B,C,D; RM7896A,B,C,D RM7897A,C and RM7898A Relay Modules 7800 SERIES: EC7895A,C; RM7895A,B,C,D; RM7896A,B,C,D RM7897A,C and RM7898A Relay Modules SPECIFICATION DATA The RM7897A1002 offers selectable pilot operation, intermittent on terminal 8 or interrupted

More information

Installation & Operation Manual

Installation & Operation Manual tekmarnet 2 House Control 403 Installation & Operation Manual D 403 07/11 HVAC Systems Replaces: 09/10 Introduction The House Control 403 is designed to operate as part of a complete hydronic heating system

More information

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc. MODEL 3200-Plus Temp Limit / LWCO Control with Thermal Targeting for Water Boilers 120 VAC Input / 24 VAC Burner Circuit PATENT. 7,891,572 INSTALLATION INSTRUCTIONS and OPERATING MANUAL Saves Fuel Features

More information

Inventory Management Guide

Inventory Management Guide MID-ATLANTIC Inventory Management Guide Honeywell Residential Combustion is the industry leader in combustion controls for applications including warm air furnaces, boilers, commercial water heaters, hearth,

More information

Installation & Operation Manual

Installation & Operation Manual tekmarnet 2 House Control 400 Installation & Operation Manual D 400 09/13 HVAC Systems Replaces: 09/10 Introduction The tn2 House Control 400 is designed to operate all of the mechanical equipment in a

More information

Installation & Operation Manual

Installation & Operation Manual tekmarnet 2 House Control 400 Installation & Operation Manual D 400 09/10 HVAC Systems Replaces: 01/10 Introduction The House Control 400 is designed to operate as part of a complete hydronic heating system

More information

Better Design, Better Control, Better Systems.

Better Design, Better Control, Better Systems. Product Catalog Better Design, Better Control, Better Systems. At tekmar Control Systems, we believe the indoor comfort of a building depends on the performance of its heating, ventilating & air conditioning

More information

MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL

MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL The EM-10 Boiler Temperature Control (BTC) is an efficient boiler operator with a digital LCD display with backlight, a boiler pump

More information

Q7800H Integrated Burner Control Subpanel

Q7800H Integrated Burner Control Subpanel Q7800H Integrated Burner Control Subpanel INSTALLATION INSTRUCTIONS FEATURES Unique subpanel design eliminates extensive wiring in the OEM control panel. One subpanel design covers multiple applications.

More information

Interrupted Ignition Series Oil Primary Control

Interrupted Ignition Series Oil Primary Control Interrupted Ignition Series Oil Primary Control Application Guide & Installation Instruction for ICM1511*, ICM1512*, ICM151*, ICM1514* For more information on our complete range of American-made products

More information

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001 SLATE Sub-Base Module R8001S9001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform

More information

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc. MODEL 3200-Plus Temp Limit / LWCO Control with Thermal Targeting for Water Boilers 120 VAC Input / 24 VAC Burner Circuit PATENT. 8,931,708; 8,844,834; 7,891,572; others pending INSTALLATION INSTRUCTIONS

More information

RA889A Switching Relay

RA889A Switching Relay Switching Relay INSTALLATION INSTRUTIONS APPLIATION The Switching Relay provides intermediate switching of line- and low-voltage devices from a line- or low-voltage controller and is typically applied

More information

Sola Hydronic Control. An Eco-Friendly Solution.

Sola Hydronic Control. An Eco-Friendly Solution. Sola Hydronic Control An Eco-Friendly Solution. Honeywell s Sola Boiler Control saves you money and reduces your carbon footprint! Efficient Boiler Control Honeywell s Sola Boiler Control offers energy

More information

Boiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand

Boiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand Date Code - Data Brochure Universal Reset Control 374 D 374 10/03 The tekmar Universal Reset Control 374 is designed to maximize the comfort and effi ciency provided by a hydronic heating system. The control

More information

7800 SERIES EC7890A,B; RM7890A,B,C Relay Module

7800 SERIES EC7890A,B; RM7890A,B,C Relay Module 7800 SERIES EC7890A,B; RM7890A,B,C Relay Module SPECIFICATION DATA EC7890 APPLICATION RM7890 The Honeywell EC7890A,B/RM7890 is a microprocessor based integrated burner control for automatically fired gas,

More information

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface

More information

S9360, S9361, S9370, S9371 Integrated Boiler Controllers

S9360, S9361, S9370, S9371 Integrated Boiler Controllers S9360, S9361, S9370, S9371 Integrated Boiler Controllers INSTALLATION INSTRUCTIONS SPECIFICATIONS IMPORTANT: The specifications given in this publication do not include normal manufacturing tolerances.

More information

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153 INDEX GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 Model(s) Page(s) Flush Mount Fan/Limit/Attic Fan Control... 152 GAS DRYER VALVES 153 Model(s)

More information

L8151A Triple Aquastat Relay

L8151A Triple Aquastat Relay L85A riple Aquastat Relay he L85A is a remote bulb controller for use with hydronic heating systems that include domestic hot water service. Provides high limit, low limit, and circulator control for maintaining

More information

7800 SERIES EC7885A/RM7885A Relay Module

7800 SERIES EC7885A/RM7885A Relay Module 7800 SERIES EC7885A/RM7885A Relay Module SPECIFICATION DATA 1. Torch-ignited main burner using the S445A Start-Stop Station, or any conventional knee or foot operated start-stop station. 2. Torch-ignited

More information

B-40/B-41 Modulating Temperature Controller

B-40/B-41 Modulating Temperature Controller INSTALLATION & OPERATING INSTRUCTIONS B-40/B-41 Modulating Temperature Controller For Raytherm Boilers & Water Heaters H2 514-4001 WH2 2100-4001 Catalog No. 5000.70 Effective: 12-21-11 Replaces: NEW P/N

More information

- Data Brochure Universal Reset Module 423

- Data Brochure Universal Reset Module 423 - Data Brochure Universal Reset Module 423 D 423 08/07 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in

More information

SC-3 Controller INSTALLATION AND OPERATING INSTRUCTIONS FOR GAS-FIRED, OIL FIRED AND DUAL FUEL HOT WATER HEATING PLANTS. SC-3 Applications CONTENTS

SC-3 Controller INSTALLATION AND OPERATING INSTRUCTIONS FOR GAS-FIRED, OIL FIRED AND DUAL FUEL HOT WATER HEATING PLANTS. SC-3 Applications CONTENTS FOR GAS-FIRED, OIL FIRED AND DUAL FUEL HOT WATER HEATING PLANTS SC-3 Controller MODULAR BOILER CONTROLLER SERIES INSTALLATION AND OPERATING INSTRUCTIONS SC-3 Applications Space Heat Systems With Outdoor

More information

T7984 A,B,C Electronic Modulating Control Thermostats

T7984 A,B,C Electronic Modulating Control Thermostats T7984 A,B,C Electronic Modulating Control Thermostats FEATURES PRODUCT DATA APPLICATION These microprocessor-based thermostats provide proportional - integral (PI) individual room temperature control in

More information

24 VAC Intermittent Pilot Gas Ignition Control

24 VAC Intermittent Pilot Gas Ignition Control C610U Universal 24 VAC Intermittent Pilot Gas Ignition Control Issue Date: 08/24/2016 Quick Reference Guide The C610U Universal Intermittent Pilot Gas Ignition Control module replaces many popular flame

More information

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc. MODEL 3150 Combination Low Water Cut-Off & Universal Temperature Limit Control for Oil-Fired Boilers 120 VAC Operating Voltage PATENT S. 7,891,572; 8,931,708 INSTALLATION INSTRUCTIONS and OPERATING MANUAL

More information

L7224A,C; L7248A,C,L Oil Electronic Aquastat Controllers

L7224A,C; L7248A,C,L Oil Electronic Aquastat Controllers L74A,C; L748A,C,L Oil Electronic Aquastat Controllers APPLICAION he L74A,C and L748A,C,L Oil Electronic Aquastat Controllers provide electronic temperature sensing in a UL limit-rated control with a single

More information

Instructions. Easy-wire terminal strip Microprocessor-operated. Easy remote sense. Self-checking program. Diagnostic/status LED s

Instructions. Easy-wire terminal strip Microprocessor-operated. Easy remote sense. Self-checking program. Diagnostic/status LED s Instructions Rear (size reduced) Easy-wire terminal strip Microprocessor-operated Front (Processor coordinates operation and diagnostic) Easy remote sense (Electronic sensor, wired to control) Self-checking

More information

Powers Controls ET 134 Low Temperature Detection Thermostat

Powers Controls ET 134 Low Temperature Detection Thermostat Document No. 155-115P25 ET 134-20 Powers Controls ET 134 Low Temperature Detection Thermostat Description Features Product Numbers The Electric Low Temperature Detection Thermostat is a remote bulb instrument

More information

- Data Brochure D 260. Boiler Control /09

- Data Brochure D 260. Boiler Control /09 - Data Brochure Boiler Control 260 D 260 03/09 The Boiler Control 260 is designed to control a single stage heat source in order to provide outdoor reset or Domestic Hot Water () operation. The control

More information

Powers Controls Low Temperature Detection Thermostat

Powers Controls Low Temperature Detection Thermostat Document No. 155-016P25 ET 134-22 Rev. 1, February, 2000 Powers Controls Low Temperature Detection Thermostat Description The electric Low Temperature Detection Cut-out and Alarm Thermostat is a remote

More information

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc. MODEL 3250-Plus Temp Limit / LWCO Control with Thermal Targeting for Water Boilers 120 VAC Operating Voltage PATENT. 8,931,708; 8,844,834; 7,891,572; others pending INSTALLATION INSTRUCTIONS and OPERATING

More information

DHW / Setpoint Demand WWSD Modulation Boiler Output (x10,000 BTU/hr) External Input Signal Offset / Priority Override

DHW / Setpoint Demand WWSD Modulation Boiler Output (x10,000 BTU/hr) External Input Signal Offset / Priority Override Date Code - Data rochure oiler Control 265 D 265 10/03 The tekmar oiler Control 265 can control the supply water temperature on up to three modulating boilers based on outdoor temperature or setpoint requirements.

More information

T6984 A,D,E Electronic Floating Control Thermostats

T6984 A,D,E Electronic Floating Control Thermostats T6984 A,D,E Electronic Floating Control Thermostats FEATURES PRODUCT DATA PI (proportional and integral) control action provides accurate, stable room temperature control. T6984 models are used with Series

More information

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc. MODEL 3200-Plus Temp Limit / LWCO Control with Thermal Targeting for Water Boilers 120 VAC Input / 24 VAC Burner Circuit PATENT. 8,931,708; 8,844,834; 7,891,572; others pending INSTALLATION INSTRUCTIONS

More information

Heat Link. Technical Guide

Heat Link. Technical Guide Heat Link Stat Link Technical Guide Third Version, May 2011 1 Table of Contents Thermostatic Zones Defined...................................... 4 StatLink System Components.....................................

More information

Part Number Color Cool Current Dimensions -H x W x D (Inch) Voltage Description THM5320R1000 Gray 1.0 A running 8-1/8 x 8 x 1-7/8 18 to 30 Vac

Part Number Color Cool Current Dimensions -H x W x D (Inch) Voltage Description THM5320R1000 Gray 1.0 A running 8-1/8 x 8 x 1-7/8 18 to 30 Vac Arctic White Cover Plate Model 50028399-001 Part Number Color 50028399-001 Arctic White 7-7/8 x 5-1/2 Wallplate for the THX9000 Series ats Equipment Interface Module Model THM5320 Easily relocate thermostat

More information

T6984F,G Electronic Floating Control Thermostats

T6984F,G Electronic Floating Control Thermostats T6984F,G Electronic Floating Control Thermostats FEATURES PRODUCT DATA P+I control action provides accurate, stable room temperature control. Used with ML644 Series 60 Direct Coupled Damper Actuators.

More information

Installation & Operation Manual

Installation & Operation Manual tekmarnet 2 House Control 406 Installation & Operation Manual 406_D 11/12 Alternative Energy Replaces: 12/11 Introduction The tn2 House Control 406 is designed to operate the equipment in a 2-pipe, single

More information

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

YP7999A1000 ControLinks Fuel Air Ratio Control Panel YP7999A1000 ControLinks Fuel Air Ratio Control Panel FEATURES INSTALLATION INSTRUCTIONS Pre-wired and ready to install Includes the R7999A control, wiring subbase and S7999D1048 touchscreen display Commission,

More information

ARM SERIES Switching Relays With Priority

ARM SERIES Switching Relays With Priority Models ARM-2P ARM-3P ARM-4P ARM-6P AD-1 AD-4 ARM SERIES Switching Relays With Priority INSTALLATION, OPERATION & MAINTENANCE MANUAL ARM-2P ARM-4P AD-1 ARM-3P ARM-6P AD-4 Information and specifications

More information

C6097A,B Pressure Switches

C6097A,B Pressure Switches C6097A,B Pressure Switches FEATURES PRODUCT DATA APPLICATION The C6097 Pressure Switches are safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure changes.

More information

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031 SLATE Rectification Ampli-Check Flame Amplifier R8001V1031 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single

More information

- Data Brochure Boiler Control 274

- Data Brochure Boiler Control 274 - Data Brochure Boiler Control 274 274_D 03/17 The Boiler Control 274 operates up to four on/off boilers to provide outdoor reset operation, domestic hot water and setpoint operation with priority. When

More information

SC-9 Controller INSTALLATION AND OPERATING INSTRUCTIONS. SC-9 Applications CONTENTS

SC-9 Controller INSTALLATION AND OPERATING INSTRUCTIONS. SC-9 Applications CONTENTS SC-9 Controller MODULAR BOILER CONTROLLER SERIES INSTALLATION AND OPERATING INSTRUCTIONS SC-9 Applications Space heat systems with outdoor reset Constant temperature setpoint control Any of these in combination

More information

7800 SERIES 22-Terminal Universal Subbase

7800 SERIES 22-Terminal Universal Subbase 7800 SERIES 22-Terminal Universal Subbase FEATURES PRODUCT DATA Q7800B003/2003/U Metal Wall-mount subbase Q7800A005/2005/U Plastic Wall-mount subbase Quick-mount wiring subbase for all 7800 SERIES Relay

More information

THERMOSTATS THERMOSTATS HEATING AND COOLING

THERMOSTATS THERMOSTATS HEATING AND COOLING THERMOSTATS HEATING AND COOLING LASCO CONTROLS Deluxe Horizontal Thermostats 36-0214 25 Millivolt Heat only 36-0215 1 36-0216 25 24 Volt Heat only 36-0217 1 36-0218 25 24 Volt Heat/Cool 36-0219 1 Note:

More information

T4398A,B Precision Electric Heating Thermostat

T4398A,B Precision Electric Heating Thermostat T398A,B Precision Electric Heating Thermostat FEATURES PRODUCT DATA APPLICATION The T398 Electric Heating Thermostat provides precise, accurate line voltage control of electric heating equipment. A snap

More information

Oxygen (O2) Single-Point Gas Detection System

Oxygen (O2) Single-Point Gas Detection System Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity

More information

ProRadiant Basic Heating Control Installation Manual 2013

ProRadiant Basic Heating Control Installation Manual 2013 ProRadiant Basic Heating Control Installation Manual 2013 The Viega Basic Heating Control is designed to control the supply water temperature to a hydronic system in order to provide outdoor reset operation.

More information

S9360A, S9361A, S9380A, S9381A Integrated Boiler Controllers

S9360A, S9361A, S9380A, S9381A Integrated Boiler Controllers S9360A, S9361A, S9380A, S9381A Integrated Boiler Controllers INSTALLATION INSTRUCTIONS SPECIFICATIONS IMPORTANT: The specifications given in this publication do not include normal manufacturing tolerances.

More information

Model 60200FR Gas Primary Control Data Sheet

Model 60200FR Gas Primary Control Data Sheet Programmable, Microprocessor Based Gas Burner Primary Controls On-Board LCD Screen Easy to Understand Icons for Inputs and Outputs Displays micro-amp Flame reading Display operational information Fault

More information

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL Figure 1 Series 9 Intermittent Pilot Ignition Control Application The Series 9 Intermittent Pilot Ignition Control is a microprocessor

More information

- Data Brochure Mixing Control 361

- Data Brochure Mixing Control 361 TIME PRGM 1 2 AMPM UN OVR S M T W T F S - Data Brochure Mixing Control 361 D 361 05/00 The Mixing Control 361 is designed to control the supply water temperature to a hydronic system in order to provide

More information

RA890G Protectorelay Primary Control

RA890G Protectorelay Primary Control Protectorelay Primary Control The RA890G Protectorelay control provides solid state electronic safeguard protection for industrial and commercial gas, oil, or combination gas-oil burners. Designed for

More information

CONTROLS THERMOSTATS Bulletin No November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS ENGINEERING DATA

CONTROLS THERMOSTATS Bulletin No November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS ENGINEERING DATA ENGINEERING DATA CONTROLS THERMOSTATS Bulletin No. 210125 November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS L21 SERIES THERMOSTATS HEAT/COOL SYSTEMS Features (All Models): Extra

More information

WARNING FLAIR INTERNATIONAL CORPORATION 600 OLD WILLETS PATH HAUPPAUGE, NEW YORK U.S.A. TEL.: (516) FAX: (516) AMERICAN

WARNING FLAIR INTERNATIONAL CORPORATION 600 OLD WILLETS PATH HAUPPAUGE, NEW YORK U.S.A. TEL.: (516) FAX: (516) AMERICAN 600 OLD WILLETS PATH HAUPPAUGE, NEW YORK 11788 U.S.A. TEL.: (516) 234-3600 FAX: (516) 234-3610 SPECIFICATIONS, INSTALLATION INSTRUCTIONS AND TROUBLE-SHOOTING GUIDE FOR STACK PACK MOTORIZED VENT DAMPER

More information

Aquatrol Outdoor Temperature Compensators AQ675A for Floating Control Valves AQ775A for Injection Pumps

Aquatrol Outdoor Temperature Compensators AQ675A for Floating Control Valves AQ775A for Injection Pumps Aquatrol emperature Compensators AQ675A for Floating Control s AQ775A for Injection Pumps FEAURES PRODUC DAA Automatic reset curve calculation. Adjustable settings for mixing maximum temperature, boiler

More information

- Data Brochure Steam Control 279

- Data Brochure Steam Control 279 - Data Brochure Steam Control 279 D 279 12/07 The tekmar Steam Control 279 can operate a single on-off steam boiler or an on-off steam valve using outdoor reset. The control determines the on time of the

More information

Project Name: Location: Engineer: Contractor: I. GENERAL

Project Name: Location: Engineer: Contractor: I. GENERAL Part I - General Part II - Product Part III - Installation Project Name: Location: Engineer: Contractor: I. GENERAL I. PRODUCT Rep: Date: A. Supply and install modulating and condensing boiler(s) as specified

More information

7800 SERIES RM7840E,G,L,M Relay Module

7800 SERIES RM7840E,G,L,M Relay Module 7800 SERIES RM7840E,G,L,M Relay Module APPLICATION SPECIFICATION DATA The Honeywell RM7840 is a microprocessor based integrated burner control for automatically fired gas, oil or combination fuel single

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 50V64-743 Integrated Furnace Control for Furnaces with Variable Fan Speed INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY

More information