UNIT INFORMATION. Corp L7. Gauge Manifold Attachment... Page 30 Parts Arrangement... Page 8

Size: px
Start display at page:

Download "UNIT INFORMATION. Corp L7. Gauge Manifold Attachment... Page 30 Parts Arrangement... Page 8"

Transcription

1 SERVICE UNIT INFORMATION Corp L7 CHA TON UNITS Litho U.S.A. CHA16 series units in the 2 5 ton sizes were introduced in the spring of The single package cooling units may be used in both residential and commercial applications. Electric heat is available in several Kw sizes. Units are designed for rooftop or side of building installation with either bottom or horizontal discharge. For commercial applications, the CHA16 is designed to accept any of several different thermostat control systems with minimum field wiring. Control options such as economizer, warm up kit, Honeywell W973 control or Honeywell W7400 control connect to the unit with jack plugs. When plugged in the controls become an integral part of the unit wiring. Commercial units are also equipped with a low voltage terminal strip to facilitate thermostat field wiring. CHA16 SERIES UNITS 2 THROUGH 5 TON UNITS All specifications in this manual are subject to change. TABLE OF CONTENTS Introduction Page 1 Heating Elements Page 29 Specifications Pages 2-4 IV PLACEMENT AND INSTALLATION Page 30 Electrical Data Page 5 V ELECTRICAL CONNECTIONS Page 30 Accessory Air Resistance Data Page 5 VI START-UP Page 30 Diffuser Air Resistance Data Page 5 VII REFRIGERATION SYSTEM SERVICE CHECKS. Pages 30,31 Blower Performance Data Pages 6-8 Gauge Manifold Attachment Page 30 Parts Arrangement Page 8 Charging Pages I APPLICATION Page 9 VIII BLOWER OPERATION AND ADJUSTMENT Page 32 II UNIT COMPONENTS Page 3 Blower Operation Page 32 Control Box Components Pages 9-13 Determining Unit CFM Page 32 Control Transformer Page 11 Blower Speed Adjustment Pages Low Voltage Terminal Strip Page 11 IX MAINTENANCE Page 35 Low Voltage Fuse Page 11 Filters Page 35 Cooling Contactor Page 11 Lubrication Page Volt Autotransformer Page 12 Electric Heat Page 36 Indoor Blower Relay Page 12 Evaporator Coil Page 36 Potential Relay Page 12 Condenser Coil Page 36 Start Capacitor Page 12 Electrical Page 36 Dual Capacitor Page 12 X ACCESSORIES Page 36 Compressor Run Capacitor Page 13 Lifting Lugs Page 36 Condenser Fan Capacitor Page 13 RMF16 Roof Mounting Frame Pages Cooling Components Pages Economizers Pages Compressor Page 15 Condenser Coil Guard Kit Page 46 Loss of Charge Switch Page 15 Compressor Crankcase Heater Page 46 Condenser Coil Page 15 DF16 Downflow Filter Kit Page 46 Evaporator Coil Page 16 Timed-off Control Kit Page 46,47 Thermometer Well Page 17 Optional Compressor Monitor Pages 46,48 Fan and Blower Components Pages Low Ambient Kit Pages 49,50 Condenser Fan and Motor Page 17 Roof Curb Power Kit Page 51 Condenser Fan Motor Capacitor Page 17 Transitions and Supply/Return Diffusers Page 51 Blower Motor Pages 17,18 Status Panels Pages Blower Motor Capacitor Page 18 XI FIELD WIRING Pages III OPTIONAL ECH16 ELECTRIC HEAT Page 18 XII WIRING DIAGRAMS AND SEQUENCE OF OPERATION Matchups and Ratings Page 18 Components Pages Wiring Diagrams and Sequence of Operation Pages Basic Residential Unit with Basic Thermostat. Pages 68,69 Conventional Relays Page 18 CHA16H with Three-Position Economizer..... Pages 70,71 Electric Heat Specification Tables Pages CHA16H with Modulating Economizer Pages 72,73 Electric Heat Parts Arrangements Pages Basic Single-Phase Commercial Unit Pages 74,75 Thermal Heat Relays Page 27 Basic 208/230V Three-Phase Commercial Unit Pages 75,76 Resistor Page 28 Basic 460V or 575V Commercial Unit Pages 78,79 Pilot Relay Page 28 Basic Three-Position Economizer Operation.. Pages 80,81 Time Delay Page 28 Basic Modulating Economizer Operation..... Pages 82,83 Current Limiting Fuses Page 28 Warm Up Kit Operation with 3-Position Econ. Pages 84,85 Primary High Temperature Limit Pages 28,29 Warm Up Kit Operation with Modulating Econ Pages 85,86 Secondary High Temperature Limit Page 29 Night Kit Operation Pages 87,88 Thermal Cutoff Page 29 Electric Heat Operation Pages Page Lennox Industries Inc.

2 ARI Standard 270 SRN (bels) *ARI Standard 210 Ratings SPECIFICATIONS CHA16H RESIDENTIAL HORIZONTAL ONLY UNITS Model No. CHA16H 261 CHA16H 311 Total Cooling Capacity (Btuh) Total unit watts SEER (Btuh/Watts) EER (Btuh/Watts) Refrigerant (R 22) charge Evaporator Blower Evaporator Coil Condenser Coil Condenser Fan Blower wheel nominal diameter x width (in.) Motor horsepower Air volume range (cfm) Net face area (sq. ft.) Tube diameter (in.) & Number of rows Fins per inch Net face area (sq. ft.) Tube diameter (in.) & Number of rows Fins per inch Diameter (in.) & Number of blades Air volume (cfm) Motor horsepower Motor watts Condensate drain size mpt (in.) Electrical characteristics Optional Electric Heat Ratings ECH16R 5 ECH16R 7 ECH16R 10 ECH16 15 Output Btuh A.F.U.E. Output Btuh A.F.U.E. Output Btuh A.F.U.E. Output Btuh A.F.U.E. Line voltage data Recommended max. fuse size (amps) Minimum circuit ampacity Optional Lifting Lug Kit Optional Condenser Coil Guards Optional Duct Enclosure Number and size of filters (in.) Optional Roof Mounting Frame (used with RDE16 41 only) Optional Model 3 position Economizer No. Modulating Dampers Number and Indoor with Gravity Exhaust size of filters (in.) Outdoor Step Down Optional Ceiling Supply and Flush Return Air Diffusers Transition Optional Outdoor Air Dampers (manual) Annual Fuel Utilization Efficiency based on DOE test procedures and FTC labeling regulations. Two stage cooling thermostat required with economizer applications. Sound Rating Number in accordance with ARI Standard 270. Indoor filter is not furnished and must be field provided , lbs. 12 oz. 9 x 7 1/ / / / / /230 volts 60 hz 1 phase LB 62125DB LB 82199CA RDE16 41 (1) 20 x 24 x 1 (fiberglass) RMF16 41 REMD16 41 REMD16M 41 (1) 16 x 25 x 1 (1) 14 x 25 x 1 (aluminum mesh) *Rated in accordance with ARI Standard 210 and DOE; 95 F outdoor air temperature and 80 F db/67 F wb entering evaporator air. **For LPG units a field changeover kit is required and must be ordered extra. 19, % 25, % 35, % 52, % RTD9 65 FD9 65 SRTH16 65 OAD3 46/ , lbs. 10 oz. 9 x 8 1/ / / / /4 19, % 25, % 35, % 52, % Page 2

3 SPECIFICATIONS CHA16R RESIDENTIAL UNITS Model No. ARI Standard 270 SRN (bels) *ARI Total Cooling Capacity (Btuh) Standard Total unit watts 210 SEER (Btuh/Watts) Ratings EER (Btuh/Watts) Refrigerant (R 22) charge Blower wheel nom. dia. x width (in.) Evaporator Motor horsepower Blower Air volume range (cfm) Net face area (sq. ft.) Evaporator Tube dia. (in.) & Number of rows Coil Fins per inch Outer coil Net face area (sq. ft.) Inner coil Condenser Tube dia. (in.) & Number of rows Coil Fins per inch Diameter (in.) & Number of blades Condenser Air volume (cfm) Fan Motor horsepower Motor watts Condensate drain size mpt (in.) Line voltage Recommended max. fuse size (amps) data Minimum circuit ampacity Electrical characteristics Output Btuh ECH16R 5 A.F.U.E. Output Btuh ECH16R 7 A.F.U.E. Optional Electric Heat Ratings ECH16R 10 ECH16 15 ECH16R 10 ECH16 15 Optional Lifting Lug Kit Optional Condenser Coil Guards Output Btuh A.F.U.E. Output Btuh A.F.U.E. Output Btuh A.F.U.E. Output Btuh A.F.U.E. Optional Downflow Adaptor Kit Model no, Filters Optional Outdoor Air Dampers (manual) CHA16R , lbs. 12 oz. 10 x 7 1/ / / / / LB 82199CB OAD16 41 CHA16R , lbs. 9 oz. 10 x 8 1/ / / / / /230 volts 60 hz 1 phase DF16 65, (1) 20x25x1 LB 62125DB(polyurethane) LB 82199CC OAD16 65 CHA16R , lbs. 0 oz. 12 x 8 3/ / , % 26, % 36, % 53, % 70, % DF16 41, (1) 16x25x1 (polyurethane) 27, % 37, % 54, % 71, % 88, % 3/ / / , % 37, % 54, % 71, % 88, % Annual Fuel Utilization Efficiency based on DOE test procedures and FTC labeling regulations. Sound Rating Number in accordance with ARI Standard 270. *Rated in accordance with ARI Standard 210 and DOE; 95 F outdoor air temperature and 80 F db/67 F wb entering evaporator air. **For LPG units a field changeover kit is required and must be ordered extra. Page 3

4 Model No. ARI Standard 270 SRN (bels) *ARI Standard 210 Ratings Refrigerant (R 22) charge Evaporator Blower Evaporator Coil Condenser Coil Condenser Fan Total Cooling Capacity (Btuh) Total unit watts SEER (Btuh/Watts) EER (Btuh/Watts) Blower wheel nominal dia. x width (in.) Motor horsepower Air volume range (cfm) Net face area (sq. ft.) Tube dia. (in.) & No of rows & Fins/in. Net face area (sq. ft.) outer/inner Tube diameter (in.) & Number of rows Fins per inch Diameter (in.) & Number of blades Air volume (cfm) Motor horsepower & Motor watts Condensate drain size mpt (in.) Recommended max. Line voltage fuse size (amps) Data (60hz) Minimum circuit ampacity Electrical characteristics ECH16R 5 ECH16R 7 SPECIFICATIONS CHA16 COMMERCIAL UNITS 208/230v 1 ph 3 ph 460v 3 ph 1 ph 208/230v 3 ph 460v 3 ph Output Btuh A.F.U.E. Output Btuh A.F.U.E. Output Btuh A.F.U.E. Output Btuh CHA CHA CHA CHA CHA CHA , lbs. 12 oz. 10 x 7 1/ / /8.40 3/ / /4 45 *Rated in accordance with ARI Standard 210 and DOE; 95 F outdoor air temperature and 80 F db/67 F wb entering evaporator air. Older CHA16 series units use optional field installed lifting lug kit LB 62125DB , lbs. 9 oz. 10 x 8 1/ / /5.90 3/ / / , lbs. 0 oz. 12 x 8 3/ / / / / / /230 volts 60 hz 1 or 3 phase 460 or 575 volts 3 phase 19, % 26, % 36,000 27, % 37,000 27, % 37,000 Optional ECH16R 10 Electric 99.0% 99.0% 99.0% 53,000 54,000 54,000 Heat ECH16 15 A.F.U.E. Ratings 99.0% 99.0% 99.0% Output Btuh 70,000 71,000 71,000 ECH16R 10 A.F.U.E. 99.0% 99.0% 99.0% ECH16 15 Output Btuh 88,000 88,000 A.F.U.E. 99.0% 99.0% Lifting Lugs (Brackets) Optional Condenser Coil Guards Furnished, Field Installed LB 82199CB Furnished, Factory Installed LB 82199CC Number and Size of Filters (in.) (1) 16x25x1 (polyurethane) (1) 20x25x1 (polyurethane) Optional Roof Mounting Frame RMF16 41 RMF16 41 or RMF position REMD16 41 REMD16 65 Optional Economizer Model No. Modulating REMD16M 41 REMD16M 65 Dampers No. & size Indoor (1) 14 x 25 x 1 (polyurethane) (1) 18 x 25 x 1 (polyurethane) of filters (in.) Outdoor (1) 14 x 25 x 1 (aluminum mesh) (1) 18 x 25 x 1 (aluminum mesh) Optional 3 position EMDH16 41 EMDH16 65 Horizontal Modulating EMDH16M 41 EMDH16M 65 Economizer Model No. No. & size Indoor (1) 20 x 24 x 1 (fiber glass) (1) 16 x 25 x 1 & (1) 14 x 25 x 1 (fiber glass) Dampers of filters (in.) Outdoor (1) 8 x 24 x 1 (aluminum mesh) (1) 8 x 28 x 1 (aluminum mesh) Optional Outdoor Air Dampers (manual) OAD16 41 OAD16 65 Step Down RTD9 65 Optional Ceiling Supply and Return Air Diffusers Flush FD9 65 Transition SRT16 65 Electromechanical Thermostat Honeywell W973 Control System with T7067 Thermostat Optional Controls Selection Honeywell W7400 Control System with T7400 Thermostat Flexstat Thermostat (discontinued as an option after August 1989) Prostat Thermostat T7300 Thermostat Downflow application 23H13 23H14 Optional Control Mounts Horizontal application 24H61 Commercial Controls Furnished Factory Installed Optional Gravity Exhaust Dampers GEDH16 65 (use with EMDH16 or EMDHM16) Optional Roof Curb Power Entry Kit Annual Fuel Utilization Efficiency based on DOE test procedures and FTC labeling regulations. 18H70 (1/2 ) Furnished as standard.consists of: factory installed controls wiring harness, high pressure switch, loss of charge switch, low voltage terminal strip and compressor crankcase heater. Sound Rating Number in accordance with ARI Standard 270. Page 4

5 Model No. ELECTRICAL DATA CHA16H AND CHA16(R) MODELS SINGLE PHASE VOLTAGE CHA16H-261 CHA16H-311 CHA16(R) 411 CHA16(R) 511 CHA16(R) 651 Line Voltage Data - 60Hz. 1ph Rated Load Amps Compressor Locked Rotor Amps Condenser Full Load Amps Fan Motor Locked Rotor Amps Evaporator Full Load Amps Blower Locked Rotor Amps Recommended Max. Fuse Size (amps) Unit Power Factor *Minimum Circuit Ampacity 208/230v 208/230v /230v /230v /230v Model No. CHA MODELS THREE PHASE VOLTAGE CHA CHA CHA Line Voltage Data - 60Hz. 3ph 208/230v 460v 575v 208/230v 460v 575v 208/230v 460v Compressor Rated Load Amps Locked Rotor Amps Condenser Full Load Amps Fan Motor Locked Rotor Amps Evaporator Full Load Amps Blower Locked Rotor Amps Recommended Max. Fuse Size (amps) Unit Power Factor *Minimum Circuit Ampacity Where current does not exceed 60 amps, HACR circuit breaker may be used in place of fuse. NOTE Extremes of operating range are plus and minus 10% of line voltage. *Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements. Motors are rated at 460 volts. Full Load Amps shown are for step-down transformer output. 575v Unit Model No. CHA16H 261 CHA16H 311 CHA CHA CHA Air Volume (cfm) With 1 Filter REMD16 Downflow Economizer Without Filter NOTE Electric heaters have no appreciable air resistance. *Air resistance is with air filter in place. Air resistance is with pleated non-woven cotton fabric filter. With Pleated 2 Filter ACCESSORY AIR RESISTANCE With Fiberglass 2 Filter Total Resistance (inches water gauge) EMDH16 Economizer Downflow With 1 Filter Without Filter *RDE16 41 Duct Enclosure DF16 Downflow Filter Adaptor Kit With 1 Filter With Pleated 2 Filter With Fiberglass 2 Filter Wet Evaporator Coil Page 5

6 Unit Model Number CHA16H-261 CHA16H-311 CHA CHA CHA DIFFUSER AIR RESISTANCE Air Volume (cfm) Ends Open RTD9 65 Diffuser 1 Side 2 Ends Open All Ends & Sides Open FD9 65 Diffuser CHA16H-261 BLOWER 230 VOLTS (With Horizontal Supply and Return Air Openings) External Static Air Volume Various Speeds Pressure(in. wg) High Med High Med Low Low NOTE All cfm data is measured external to unit. CHA16(R) BLOWER 230 VOLTS (With Horizontal Supply and Return Air Openings) External Static Air Volume Various Speeds Pressure(in. wg) High Med High Med Low Low NOTE All cfm data is measured external to unit. CHA16(R) BLOWER 230 VOLTS (With Horizontal Supply and Return Air Openings) External Static Air Volume Various Speeds Pressure(in. wg) High Med High Med Low Low NOTE All cfm data is measured external to unit. CHA16H-311 BLOWER 230 VOLTS (With Horizontal Supply and Return Air Openings) External Static Air Volume Various Speeds Pressure(in. wg) High Med High Med Low Low NOTE All cfm data is measured external to unit. CHA16(R) BLOWER 230 VOLTS (With Down Flow Supply and Return Air Openings) External Static Air Volume Various Speeds Pressure(in. wg) High Med High Med Low Low NOTE All cfm data is measured external to unit. Page 6

7 CHA16(R) BLOWER 230 VOLTS (With Down Flow Supply and Return Air Openings) External Static Air Volume Various Speeds Pressure(in. wg) High Med High Med Low Low NOTE All cfm data is measured external to unit. CHA BLOWER 460/575 VOLTS (With Horizontal Supply and Return Air Openings) External Static Air Various Speeds Pressure (in. wg) High Medium Low NOTE All cfm data is measured external to unit. CHA BLOWER 460/575 VOLTS (With Horizontal Supply and Return Air Openings) External Static Air Various Speeds Pressure (in. wg) High Medium Low NOTE All cfm data is measured external to unit. CHA BLOWER 460/575 VOLTS (With Horizontal Supply and Return Air Openings) External Static Air Various Speeds Pressure (in. wg) High Medium Low NOTE All cfm data is measured external to unit. CHA BLOWER 460/575 VOLTS (With Down Flow Supply and Return Air Openings) External Static Air Various Speeds Pressure (in. wg) High Medium Low NOTE All cfm data is measured external to unit. CHA BLOWER 460/575 VOLTS (With Down Flow Supply and Return Air Openings) External Static Air Various Speeds Pressure (in. wg) High Medium Low NOTE All cfm data is measured external to unit. Page 7

8 CHA BLOWER 460/575 VOLTS (With Down Flow Supply and Return Air Openings) External Static Air Various Speeds Pressure (in. wg) High Medium Low NOTE All cfm data is measured external to unit. CHA16(R) BLOWER PERFORMANCE@ 230 VOLTS (With Down Flow Supply and Return Air Openings) External Static Air Volume Various Speeds Pressure (in. wg) High Med High Med Med Low Low NOTE All cfm data is measured external to unit. CHA16(R) BLOWER PERFORMANCE@ 230 VOLTS (With Horizontal Supply and Return Air Openings) External Static Air Volume Various Speeds Pressure (in. wg) High Med High Med Med Low Low NOTE All cfm data is measured external to unit. CHA16H PARTS ARRANGEMENT CONDENSER FAN OPTIONAL RETURN CHA AND CHA16 510/650 PARTS ARRANGEMENT OPTIONAL SUPPLY SUPPLY EVAPORATOR COIL SUPPLY COMPRESSOR RETURN DRAIN CONTROL SUPPLY BOX BLOWER CONTACTOR EVAPORATOR COIL OPTIONAL ELECTRIC HEAT BLOWER RETURN FIGURE 1 Page 8 CONTROL BOX OPTIONAL ELECTRIC HEAT CONDENSER COIL COMPRESSOR

9 I APPLICATION CHA ton units are available in three model and three cabinet sizes (refer to the Engineering Handbook for more specific application data). CHA16H models are available only in the smallest cabinet and are applicable for residential installations with horizontal supply and discharge air only. CHA16H units are singlephase only and are not equipped for installation of Lennox optional thermostat control systems. CHA16R models are residential only units available in both the small and large convertible (downflow or horizontal) cabinets. CHA16R models, like the CHA16H models, are single-phase only and are not equipped for installation of Lennox optional thermostat control systems. CHA16 models are residential or commercial units available in single or three-phase and available in both the small and large convertible (downflow or horizontal) cabinets. CHA16 models are factory equipped with the hardware required for installing Lennox optional thermostat control systems. Lennox optional thermostat control systems are the same controls, harnesses, and harness plugs used in all 16 series commercial air conditioners, heat pumps and gas/electrics. For example, a Honeywell W973 control will plug in to a CHA as easily as it will plug in to a CHA (and no field wiring is required for either). II UNIT COMPONENTS CHA16 unit components are shown in figure 1. A Control Box Components CHA16H control box is shown in figure 2. The control box is located adjacent to the compressor compartment behind the electric heat access panel. CHA16R 411 and CHA control box is shown in figures 3 and 4. CHA16R 511/651 and CHA16 510/650 control box is shown in figures 5 and 6. In both units, the control box is located in the heating compartment behind the heating compartment access panel. The indoor blower access panel (all units) is located on the opposite side of the unit from the control box access. Figure 1 shows typical blower compartment access. CHA16H CONTROL BOX C1 CAPACITOR WIRING GROMMET K3 BLOWER RELAY C5 CAPACITOR T1 TRANSFORMER ELECTRIC HEAT SECTION K1 CONTACTOR FIGURE 2 Page 9

10 CHA16R 411 CONTROL BOX COMPONENTS WIRING GROMMET K3 BLOWER RELAY C12 DUAL CAPACITOR F1 FUSE T1 TRANSFORMER ELECTRIC HEAT SECTION K1 COMPRESSOR CONTACTOR FIGURE 3 WIRING GROMMET T1 TRANSFORMER CHA16 411/413 CONTROL BOX COMPONENTS C12 DUAL CAPACITOR (-411 Units) C1 FAN CAPACITOR (-413 UNITS) F1 FUSE K3 BLOWER RELAY T4 AUTO TRANSFORMER (CHA J only) TB1 TERMINAL BOARD WIRING GROMMET K31 POTENTIAL RELAY K3 BLOWER RELAY FIGURE 4 CHA16R 511/651 CONTROL BOX ELECTRIC HEAT SECTION K1 COMPRESSOR CONTACTOR C7 START CAPACITOR C12 DUAL CAPACITOR F1 FUSE T1 TRANSFORMER FIGURE 5 ELECTRIC HEAT SECTION K1 COMPRESSOR CONTACTOR Page 10

11 K3 BLOWER RELAY WIRING GROMMET CHA16 511/513/651/653 CONTROL BOX K31 POTENTIAL RELAY CHA16 511/651 units only C7 START CAPACITOR CHA16 511/651 units only T4 AUTO TRANSFORMER (CHA16 513/ v only) LOCATION FOR P AND Y VOLTAGE T1 TRANSFORMER F1 FUSE TB1 TERMINAL BOARD 1 Transformer T1 K1 COMPRESSOR CONTACTOR FIGURE 6 3 Transformer Fuse F1 LOCATION FOR G AND J VOLTAGE C12 DUAL CAPACITOR (CHA16 511/651 only) OR C1 CAPACITOR (CHA16 513/653 only) CHA16 series units use a single line voltage to 24VAC transformer located in the control box. The transformer supplies power to control circuits in the unit. Transformers are rated as shown in table 1. P voltage (208/230V) transformers use two primary voltage taps as shown in figure 7. Unit CHA16H-261 CHA16H-311 CHA16R-411/511/651 CHA16-411P/413Y CHA16-511P/513Y CHA16-651P/653Y CHA16-413G CHA16-513/653G CHA16-413/513/653J 2 Terminal Strip TB1 208 / 230 VOLT TRANSFORMER PRIMARY ORANGE 240 VOLTS RED 208 VOLTS BLACK TABLE 1 T1 TRANSFORMER RATING Primary Secondary 230VAC FIGURE 7 24VAC SECONDARY YELLOW BLUE VA Rating Internal Fuse 45 No Fuse 208/ 230VAC 24VAC A 480VAC 24VAC A 440VAC 24VAC A 575VAC 24VAC A All CHA16 commercial units are equipped with a low voltage terminal strip (TB1). The strip is used for making up all indoor thermostat and outdoor unit low voltage control wiring connections (see figures 4 and 6). The terminal strip is located at the bottom left corner of the control box. Transformers used in CHA16H and CHA16R units are not equipped with internal secondary voltage overcurrent protection. Transformers in all other units are equipped with an integral fuse connected in series with the blue secondary voltage wire. The fuse may be accessed outside the transformer and is rated as shown in table 1. 4 Cooling Contactor K1 K1 is a 24V to line voltage contactor used to energize the compressor and condenser fan in response to thermostat demand. Three-phase units use three-poledouble-break contactors. Single-phase units use single-pole contactors. WARNING Electric shock hazard. Can cause injury or death. Single-phase units are equipped with single-pole contactors. One leg of compressor, capacitor and condenser fan are always connected to line voltage. Turn off power at disconnect before servicing. NOTE Contactor K1 is energized by the thermostat control system. Depending on the control system installed, the contactors may or may not be immediately energized upon demand. Refer to the operation sequence for the control system installed. Page 11

12 5 Autotransformer T4 CHA (575V) units use a line voltage to 460V autotransformer to power the indoor blower. The autotransformer is connected directly to line voltage and is powered at all times. It has a maximum VA rating of 3.4A. See figure 8. AUTOTRANSFORMER T4 CHA J ONLY BROWN 460V 575V BLACK FIGURE 8 6 Indoor Blower Relay K3 (Cooling Speed) 208/230 volt units use a single 2PDT relay to energize the indoor blower motor. 460 volt and 575 volt units use a single 3PDT relay. The relay coil is energized by blower demand from indoor thermostat terminal G (cooling demand or fan switch in ON position). When the coil is energized, a set of N.O. contacts closes to energize the blower motor on high speed. When there is a demand for heat, the blower is energized by the blower relay located inside the electric heat section of the unit. 460 (G) and 575(J) voltage units use a unique blower motor. The motor utilizes a set of N.C. relay contacts (K3) to complete an internal circuit when the motor is on low or medium (heating) speed. 7 Potential Relay K31 Relay K31 is used in single-phase 511 and 651 units only and is located in the control box. It is a potential relay which controls the operation of the starting circuit. The relay is normally closed when the compressor (contactor K1) is de energized. Capacitor (C7) is connected to a set of N.C. K31 contacts and is used to assist the compressor in starting. When K1 energizes, the compressor immediately begins startup. K31 remains de energized during compressor start up and the start capacitor (C7) remains in the circuit. As the compressor gains speed K31 is energized by electromotive forces generated by the compressor. When K31 energizes, its contacts open to take the start capacitor out of the circuit. 8 Start Capacitor C7 TABLE 2 Unit CHA CHA16R-511 CHA CHA16R-651 Start Capacitor Ratings C7 Start Capacitor Rating VAC VAC RED All single-phase units (size 511 and larger) use a compressor start capacitor (C7) connected in parallel with the compressor side of dual capacitor C12. The start capacitor is energized during compressor startup and is switched off by potential relay K31 when the compressor nears full speed. Three-phase units do not use start capacitors. Table 2 shows start capacitor ratings for single-phase CHA16s. The capacitor is mounted in the unit control box. See figures 5 and 6 for capacitor location. NOTE Before servicing unit, be sure to identify the compressor and fan sides of dual capacitor C12. The start capacitor uses a 15K ohm 2 watt bleed resistor connected in parallel with the capacitor terminals. A resistor is used to slowly discharge the capacitor when not in use. 9 Dual Capacitor C12 CHA16 and CHA16R three, four and five ton singlephase units use permanent split capacitor (PSC) motors in both compressor and condenser fan. A single dual capacitor is used for both. A dual capacitor is two independent capacitors inside one can. The fan side of the capacitor and the compressor side of the capacitor have different ratings. The capacitor is located inside the compressor compartment. Refer to table 3. See figures 3, 4, 5 and 6 for location. TABLE 3 Run Capacitor Ratings Unit CHA16H-261 CHA16H-311 CHA CHA16R-511 CHA CHA16R-651 CHA CHA16R-411 CHA16H-261 CHA16H-311 CHA16-413Y CHA16-413G/413J CHA16-513Y/513G/513J CHA16-653Y/653G/653J Key Number C5 C5 C12 C12 C12 C1 C1 Type/ Rating Single Capacitor 30 mfd 370V Single Capacitor 35 mfd 370V Dual Capacitor 40 mfd compressor 7.5 mfd 440V Dual Capacitor 45 mfd compressor 7.5 mfd 440V Dual Capacitor 40 mfd compressor 5 mfd 370V Single Capacitor 5 mfd 370V Single Capacitor 7 mfd 370V Page 12

13 10 Compressor Run Capacitor C5 All single-phase units use permanent-split-capacitor compressor motors which require run capacitors to maximize compressor efficiency. Three ton and larger units use the compressor side of dual capacitor C12 while units smaller than three tons use a single run capacitor C5. Table 3 shows C5 run capacitors used in CHA16 single-phase units. Three-phase units do not use run capacitors. See figures 2 through 6 for capacitor location. 11 Fan Capacitor C1 All three-phase CHA16 units use single-phase PSC condenser fan motors. Motors are equipped with a fan run capacitor to maximize motor efficiency. The fan capacitor is located in the compressor compartment and is electrically connected as shown in the unit wiring diagram. Capacitor ratings are shown in table 3. In some single phase units, the fan capacitor is combined with the compressor run capacitor in C12. Refer to dual capacitor C12. B Cooling Components Summary of Features All units use DX cooling. Cooling in commercial units (CHA16) may also be supplemented by field-installed economizer. CHA16H 261/311, CHA16 411/413 and CHA16R 411 units use a single slab type enhanced fin evaporator with rifled tubing and capillary cap tubes as the primary expansion device (figure 10). CHA16R 511/651 and CHA16 511/513/651/653 units use a single slab type enhanced fin evaporator with rifled tubing and a thermal expansion valve TXV as the primary expansion device (figure 9). CHA16R and CHA16H series units are not equipped with crankcase heater, high pressure switch or loss of charge switch. All 510/ 650 units are equipped with thermometer well for charging. All models use draw through type condenser fans. PLUMBING COMPONENTS THERMAL EXPANSION VALVE SYSTEMS HIGH PRESSURE AND LOSS OF CHARGE SWITCHES USED ON CHA16 UNITS ONLY. EXPANSION VALVE SUCTION LINE GAUGE PORT CHA CHA16(R) 510/650 THERMOMETER WELL and LIQUID GAUGE PORT LIQUID LINE GAUGE PORT LIQUID LINE EVAPORATOR COIL CONDENSER COIL SUCTION LINE GAUGE PORT CHA DISCHARGE LINE LOSS OF CHARGE SWITCH (CHA16 only) HIGH PRESSURE SWITCH (CHA16 only) COMPRESSOR TERMINAL BOX FIGURE 9 Page 13

14 CHA16H 261 PLUMBING COMPONENTS CAPILLARY TUBE SYSTEMS SUCTION LINE EVAPORATOR COIL SUCTION LINE GAUGE PORT CONDENSER COIL CAPILLARY TUBES LIQUID LINE GAUGE PORT LIQUID LINE DISCHARGE LINE COMPRESSOR TERMINAL BOX CHA16H 311 SUCTION LINE GAUGE PORT SUCTION LINE EVAPORATOR COIL CONDENSER COIL CAPILLARY TUBES LIQUID LINE LIQUID LINE GAUGE PORT CHA16(R) 410 DISCHARGE LINE SUCTION LINE COMPRESSOR TERMINAL BOX LIQUID LINE GAUGE PORT LIQUID LINE EVAPORATOR COIL CONDENSER COIL COMPRESSOR TERMINAL BOX SUCTION LINE GAUGE PORT DISCHARGE LINE HIGH PRESSURE SWITCH (CHA16 only) LOSS OF CHARGE SWITCH (CHA16 only) FIGURE 10 Page 14

15 TABLE 4 CHA16 SERIES UNITS COMPRESSOR SPECIFICATIONS Unit Voltage/ Phase Locked Rotor Amps Rated Load Amps Oil Charge Fl. Oz. Viscosity Oil Type Crankcase Heater CHA16H 261 CHA16H 311 CHA16R 411 CHA CHA Y CHA CHA16R 511 CHA CHA CHA CHA CHA16R 651 CHA CHA CHA CHA /230/1 208/230/1 208/230/1 208/230/1 208/230/3 575/3 208/230/1 208/230/1 208/230/3 460/3 575/3 208/230/1 208/230/1 208/230/3 460/3 575/ *** *** ** *** *** *** ** *** * ** None 40 watt Insertion Type Self Regulating None 30 watt Insertion Type Self Regulating None 30 watt Insertion Type Self Regulating 40 watt Insertion Type Self Regulating *Texaco Capella WF 32 or Suniso 3GS or White Oil M/M Sontex 200 LT **Heat Pump Grade Mineral ***Not Specified 1 Compressor B1 Table 4 shows the specifications of compressors used in all units. Compressors used in CHA16 commercial units are equipped with insertion type crankcase heaters. All compressors are protected by internal pressure relief valves and internal overload protection circuitry. WARNING 2 High Pressure Limit S4 Electric Shock Hazard. Can cause injury or death. Do not operate without protective cover over terminals. Disconnect power before removing protective cover. Discharge capacitors before servicing unit. The high pressure limit is a manually reset SPST N.C. switch which opens on a pressure rise. All commercial units (CHA16) are equipped with the limit. CHA16R and CHA16H are not equipped with the limit. The switch is located in the compressor discharge line and is wired in series with the compressor contactor. When discharge pressure rises above psig (indicating a problem in the system) the switch opens and the compressor is de energized ( the economizer can continue to operate.) After the problem has been found and corrected, the switch can be reset by pushing the reset button. 3 Loss of Charge Switch S24 The loss of charge switch is an auto-reset SPST N.C. switch which opens on a pressure drop. All commercial units (CHA16) are equipped with the switch. CHA16R and CHA16H are not equipped with the switch. The switch is located in the compressor discharge line and is wired in series with the high pressure switch and compressor contactor. When discharge pressure drops below 25+5 psig (indicating a loss of charge in the system) the switch opens and the compressor is de energized. The switch automatically resets when refrigerant is added and discharge line pressure rises above 55+5 psig. 4 Condenser Coil All CHA16s have a single condenser coil. Each coil has two rows (CHA16 511/513 and CHA16R 511 have 1 1/2 rows) of copper tubes fitted with ripple edged aluminum enhanced fins. Page 15

16 5 Evaporator Coil All CHA16s have a single slab evaporator coil. The coil has two rows of rifled copper tubes fitted with ripple edged aluminum fins. An expansion device feeds multiple parallel circuits through the coil. EVAPORATOR PLUMBING CHA16H 261, CHA16H 311, CHA16 411/413 and CHA16R 411 SUCTION LINE EVAPORATOR a Capillary Tube Systems CHA16H 261, CHA16H 311, CHA16 411/413 and CHA16R 411 units use capillary tubes as the primary expansion device in the indoor coil. Multiple cap tubes feed independent parallel circuits through the coil. Expansion takes place at the point where the cap tubes enter the coil. See figure 11. EVAPORATOR PLUMBING CHA16 511/513, CHA16 651/653 CHA16R 511 and CHA16R 651 CAP TUBES CAPILLARY TUBE EXPANSION DEVICE EVAPORATOR EVAPORATOR LIQUID LINE EXPANSION VALVE FED BY LIQUID LINE EVAPORATOR SENSING BULB STRAPPED TO SUCTION LINE CAPILLARY TUBE EXPANSION DEVICE LIQUID LINE CAP TUBES EQUALIZER LINE FEEDER TUBES SUCTION LINE FEEDER TUBES SUCTION LINE FIGURE 11 FIGURE 12 Page 16

17 b Expansion Valve CHA through 650 series units use a Thermal Expansion Valve (TXV) as the primary expansion device. See figure Thermometer Well (Figure 13) All CHA16 510/650 series units are factory equipped with a thermometer well for charging the unit. The well is used to accurately measure the temperature of the liquid line. The temperature measured is then used to calculate the approach or subcooling temperature. Approach and THERMOMETER WELL THERMOMETER WELL LIQUID LINE GAUGE PORT LIQUID LINE FIGURE 13 subcooling temperatures are compared to tables printed in the charging section of this manual to determine the correct charge. Thermometer wells are equipped with a gauge port for connection of high pressure gauge. To accurately measure the temperature of the liquid line, the well should be filled with a light mineral oil before using. This will ensure good heat transfer to the thermometer. C Fan and Blower 1 Condenser Fan and Motor B4 3 Blower Motor B3 All CHA16 series units use single-phase PSC blower motors. A single run capacitor is mounted on the blower housing. All motors use multiple speed taps. Typically, the high speed tap is energized during compressor operation and a lower speed tap is energized during heating operation. Blower motors in CHA16 261, 311, 411 and 511 units have four speed taps. Motors in CHA units have five speed taps. All 460 voltage units have three taps. Blower motor specifications are listed in table 6. Blower performance ratings are listed in the tables on pages 6, 7 and 8. TABLE 6 BLOWER MOTOR 1075 RPM CCW ROTATION Unit Motor Volts Phase HP FLA CHA16H 261 CHA16H 311 CHA16 411/413 CHA16R 411 CHA / / / /3 1/3 1/3 1/ CHA16 511/513 CHA16R 511 CHA / /2 3/ CHA /4 0.7 CHA16 651/653 CHA16R / /4 4.6 CHA /4 1.8 CHA /4 0.7 The table on pages 2, 3 and 4 in this manual show the specifications of condenser fans used in CHA16s. The condenser fan in all units is controlled by cooling contactor K1. The condenser fan can be accessed by removing the fan grill located on top of the unit. 2 Condenser Fan Motor Capacitor C1 All CHA16s use single-phase PSC condenser fan motors. Table 5 shows fan run capacitor ratings for CHA16s. TABLE 5 CONDENSER FAN MOTOR CAPACITOR Unit & Unit Voltage Type Volts CHA16H /230 Single CHA16H /230 Single CHA CHA16R /230 Dual (shared with compressor) CHA /230 Single CHA16 511/651 CHA16R 511/ /230 Single CHA16 413/513/653 ALL Single Page 17 A third (blue) tap on G (460V) and J (575V) volt motors is used to complete an internal circuit during low or medium speed operation. It must never be connected to line voltage. During low speed (red tap) operation, the high speed (black) tap is disconnected from line voltage and is connected to blue internal wiring tap. Internal wiring is shown in figure VOLT BLOWER MOTOR WINDINGS HIGH SPEED MEDIUM SPEED LOW SPEED WINDING WINDING WINDING ORANGE BLACK BLUE YELLOW RED The motor has three sets of windings. The high speed winding is independent of the other two and the medium and low speed windings are tied together with a center tap. High speed is accomplished by energizing the high speed windings. Medium speed is accomplished by connecting the medium speed and high speed windings in series. Low speed is accomplished by connecting the low, medium and high speed windings in series. Refer to unit wiring diagram and Corp L7. FIGURE 14

18 CAUTION Potential for damage to 460V and 575V blower motors and/or unit electrical circuits. The blue blower motor lead must never be connected to a line voltage power lead (blower demand from heat relay or blower relay). Refer to unit wiring diagram for proper wiring. Can result in improper operation, increased current flow and/or burnt windings. 4 Indoor Blower Motor Capacitor C4 All CHA16 208/230v units use single-phase PSC motors. A run capacitor is mounted on the blower housing. Capacitor ratings are shown in table v and 575v units use single-phase PSC 460v blower motors. A run capacitor is located on the blower housing. TABLE 7 Unit 208/230v Blower Capacitor Rating CHA16H 261/ 311 CHA16 411P/ 413Y CHA16R 411 CHA16 511P/ 513Y CHA16R MFD at 370 V 10 MFD at 370 V 20 MFD at 370 V CHA16 651P/ 653Y CHA16R MFD at 370 V CHA16 413G,J 10 MFD at 370 V CHA16 513G,J 10 MFD at 370 V CHA16 653G,J 20 MFD at 370 V III OPTIONAL ECH16 ELECTRIC HEAT A Matchups and Ratings Tables 8, 9, 10, 11 and 12 show all possible CHA16 to ECH16 matchups. Also shown in the tables are ECH16 electrical ratings. B Electric Heat Components ECH16 parts arrangement is shown in figures 15, 16, 17, 18, 19, 20 and 21. All ECH16 units consist of electric heating elements exposed directly to the airstream. Elements are sequenced on and off by heat relays or contactors in response to thermostat demand. 1 Relay K15 Relay K15 is a single-pole single-throw relay located on the control panel of all commercial singlephase ECH16 units (15, 20 and 25 kw). K15 is equipped with a 24VAC coil which is energized when pilot relay K43 closes. When K15 is energized, the first stage heating elements are energized. (HE1 in ECH16-15; HE1 and HE2 in ECH16-20 and ECH16-25). 2 Contactor K15 Contactor K15 is a three-pole double break contactor used in all commercial three-phase ECH16 units. K15 is equipped with a 24VAC coil which is energized when pilot relay K43 closes. When K15 is energized, the first stage heating elements are energized. Contactor K15 used in ECH Y and ECH G units is equipped with a set of auxiliary single-pole double-throw contacts. The auxiliary contacts are not used in this application. 3 Relay K16 Relay K16 is a single-pole single-throw relay located on the control panel of all commercial singlephase ECH16 units (15, 20 and 25 kw). K16 is equipped with a 24VAC coil which is energized when pilot relay K43 closes. When K16 is energized, the second stage heating elements are energized (HE2 in ECH16-15; HE3 and HE4 in ECH16-20 and ECH16-25). 4 Contactor K16 Contactor K16 is a three-pole double break contactor used in commercial 20 and 25 kw three-phase ECH16 units. K16 is equipped with a 24VAC coil which is energized when time delay DL2 closes. When K16 is energized, the second stage heating elements are energized. 5 Relay K17 Relay K17 is a single-pole single-throw relay located on the control panel of all commercial singlephase ECH16 units (15, 20 and 25 kw). K17 is equipped with a 24VAC coil which is energized when pilot relay K43 closes. When K17 is energized, the third stage heating elements are energized (HE3 in ECH16-15; HE5 and HE6 in ECH16-20 and ECH16-25). Page 18

19 TABLE 8 CHA & CHA ELECTRIC HEAT DATA Optional Single Point Power Source Boxes Single Package Unit Model No. Electric Heater Model No. & Net Weight No. of Steps & Phase Volts Input Heater Only *Minimum Circuit Ampacity Electric Heat Kw Input Electric Heat Btuh Input Heater Sub- Fuse Box Model No. Unit Sub- Fuse Box Model No. Total Unit & Electric Heat *Minimum Circuit Ampacity , ECH16R-5 1 step ,300 ECH16R- ECH (4 lbs.) (1 phase) ,700 26/ , , ECH16R-7 1 step ,100 ECH16R- ECH (5 lbs.) (1 phase) ,800 26/ CHA16H , , ECH16R-10 1 step ,700 ECH16R- ECH (5 lbs.) (1 phase) ,400 26/ , , ECH step , ECH (18 lbs.) (1 phase) , , , ECH16R-5 1 step ,300 ECH16R- ECH (4 lbs.) (1 phase) ,700 26/ , , ECH16R-7 1 step ,100 ECH16R- ECH (5 lbs.) (1 phase) ,800 26/ CHA , , ECH16RR-10 1 step ,700 ECH16R- ECH (5 lbs.) (1 phase) ,400 26/ , , ECH step , ECH (18 lbs.) (1 phase) , , *Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167 F. Page 19

20 Single Package Unit Model No. Electric Heater Model No. & Net Weight No. of Steps & Phase TABLE 9 CHA16(R) ELECTRIC HEAT DATA Volts Input Heater Only *Minimum Circuit Ampacity Electric Heat Kw Input Electric Heat Btuh Input Optional Single Point Power Source Boxes Heater Sub- Fuse Box Model No. Unit Sub- Fuse Box Model No. Total Unit & Electric Heat *Minimum Circuit Ampacity , ECH16R-5 1 step ,300 ECH16R- ECH (4 lbs.) (1 phase) ,700 26/ , , ECH16R-7 1 step ,100 ECH16R- ECH (5 lbs.) (1 phase) ,800 26/ , , ECH16R-10 1 step ,700 ECH16R- ECH CHA (5 lbs.) (1 phase) ,400 26/ CHA16R , , ECH step , ECH (18 lbs.) (1 phase) , , , ECH step , ECH (19 lbs.) (1 phase) , , , ECH step , ECH (17 lbs.) (3 phase) , , , , ECH , ECH step , (17 lbs.) (3 phase) , , ECH , , , ECH , CHA ECH step , (17 lbs.) (3 phase) , , ECH , , , ECH , ECH step , (20 lbs.) (3 phase) , , ECH , , , ECH , ECH steps , (20 lbs.) (3 phase) , , ECH , *Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 167 F. Page 20

NEW CUTAWAY POSITION ONLY

NEW CUTAWAY POSITION ONLY ENGINEERING DATA ELITE 12 ( R Models) CHP20(R)V-261-311-410-461-510-650 PACKAGED UNITS HEAT PUMPS *23,800 to 60,000 Btuh (7.0 to 17.6 kw) *22,800 to 61,000 Btuh (6.7 to 17.9 kw) 12,600 to 85,300 Btuh (3.7

More information

Corp L2 Revised

Corp L2 Revised Service Literature Corp. 08-L Revised 0-07 ZCA & ZCB SERIES, 4, 5 and 6 ton 0.6 to.kw ZCA06, 048, 060, 07 & ZCB06, 048, 060, 074 The ZCA packaged electric cooling units are available in standard cooling

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

CHA to 17.6 kw (2 to 5 Ton) Bulletin # October 1994 Supersedes October 1990 ENGINEERING DATA. CHA16 Basic Unit. CHA16H-261 Basic Unit

CHA to 17.6 kw (2 to 5 Ton) Bulletin # October 1994 Supersedes October 1990 ENGINEERING DATA. CHA16 Basic Unit. CHA16H-261 Basic Unit ENGINEERING DATA ENGINEERING DATA MATCHED PACKAGED REMOTE COOLING SYSTEMS 50hz CHA16H-261/CHA16-413, -513 AND -653 PACKAGED UNITS COOLING & ELECTRIC HEAT 6.7 to 15.7 kw (22 800 to 53 500 Btuh) Cooling

More information

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS 3HPP / rhp3 Rooftop Units 60HZ Bulletin No. 0634 October 04 Supersedes October 0 MODEL NUMBER IDENTIFICATION -PHASE MODELS Nominal SEER (3HPP Shown) Unit Type

More information

13 GEP A L P - 1 A

13 GEP A L P - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800

More information

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The

More information

Service Literature GCS/CHA16 6, 7.5, 10 and 12.5 Ton (21, 26.4, 35.2 and 44.0 kw)

Service Literature GCS/CHA16 6, 7.5, 10 and 12.5 Ton (21, 26.4, 35.2 and 44.0 kw) GCS16 series units in the 6, 7.5, 10 and 12.5 ton (21, 26.4, 35.2 and 44.0 kw) cooling sizes are packaged combination gas heat/dx cool units designed for commercial applications. Gas heat exchanger in

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2 Service Literature Corp. 0527 L10 Revised May 2011 CB26UH and CBX26UH Series Table of Contents CB26UH CBX26UH Model Number Information................... 2 Specifications / Electrical Data................

More information

High Heat COP. High/Low Stage

High Heat COP. High/Low Stage SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin

More information

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGF SERIES 7-1/2 Ton C Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Combination gas heating and electric cooling, self contained for year-round comfort. Systems can be installed

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

TGA WARNING CAUTION ROOFTOP UNITS. Service Literature. Table of Contents

TGA WARNING CAUTION ROOFTOP UNITS. Service Literature. Table of Contents TGA ROOFTOP UNITS Service Literature TGA 024 030 036 048 060 072 (10 08) The TGA packaged gas units are available in basic cooling efficiency (036B, 048B and 060B) and standard cooling efficiency (024S,

More information

B24 SERVICE UNIT INFORMATION B24 SERIES ADD-ON BLOWER ECB24 SERIES ELECTRIC HEAT

B24 SERVICE UNIT INFORMATION B24 SERIES ADD-ON BLOWER ECB24 SERIES ELECTRIC HEAT SERVICE UNIT INFORMATION Corp. 9311 L2 B24 Litho U.S.A. The B24 blower units are designed for multi-position installation with add-on C22FC/CR22/CH22 or C24FC/ CR24/CH24 series coil sections. The B24 may

More information

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Single Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS T CLASS TSA Series 6 to 20 Ton AIR CONDITIONERS 6 20 TONS 506147 01 06/11 Supersedes 3/11 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT The Clean Air Act

More information

HS25 SERVICE UNIT INFORMATION

HS25 SERVICE UNIT INFORMATION SERVICE UNIT INFORMATION HS25 Corp. 9327-L3 Litho U.S.A. HS25 SERIES UNITS The HS25 is a high efficiency residential split system condensing unit which features a scroll compressor. It operates much like

More information

Service Literature GCS/CHA16 15 and 20 Ton (52.8 and 70.3 kw)

Service Literature GCS/CHA16 15 and 20 Ton (52.8 and 70.3 kw) GCS16 series units in the 15 and 20 ton (52.8 and 70.3 kw) cooling sizes are packaged combination gas heat/ dx cool units designed for commercial applications. Gas heat exchanger in 235,000 and 375,000

More information

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGB SERIES 3thru5Ton 10 SEER C CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Combination gas heating and electric cooling, self contained for year-round comfort. Systems can be installed

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model Q4SD Series M120 Product Line Single Packaged Heat Pump 13 SEER 3-5 Ton Units 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise to replace

More information

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS Service Literature orp. 1501-L2 August 2016 Revised March 2017 LRP14HP/DF/A/GE LRP16GE/HP 2 to 5 Ton (7.0 to 17.6 kw) LRP14HP/LRP14DF/LRP14A/LRP14GE/LRP16GE/LRP16HP SERIES UNITS The LRP14/16 series packaged

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PPH1SD Series M1200 Product Line Single Packaged Heat Pump 13 SEER - 3, 4 and 5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat) ENGINEERING DATA COILS BLOWER COIL UNITS B24/C22/24 B24 SERIES ADD-ON BLOWER UNITS UP-FLO DOWN-FLO HORIZONTAL WITH C22FC/CR22/CH22 & C24FC/CH24 COILS 1-1/2 Thru 5 Ton (5.3 thru 17.6 kw) Capacity 6,400

More information

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS SUNLINE 2000ô MODELS: H5CE090, H3CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 9.0-9.5 EER DESCRIPTION These Sunline 2000ô units are completely

More information

Corp L9 Revised HS27 SERIES UNITS SPECIFICATIONS. Model No. HS HS HS HS27-042

Corp L9 Revised HS27 SERIES UNITS SPECIFICATIONS. Model No. HS HS HS HS27-042 Service Literature Corp. 9619 L9 Revised 08 2004 HS27 SERIES UNITS HS27 The HS27 is a 14 SEER high efficiency residential split system condensing unit which features a scroll compressor. It operates much

More information

HEAT EXCHANGER Aluminized serpentine clamshell heat exchanger provides corrosion resistance for longer life and efficient heat transfer.

HEAT EXCHANGER Aluminized serpentine clamshell heat exchanger provides corrosion resistance for longer life and efficient heat transfer. AIR CONDITIONER GPFM Series SPECIFICATIONS 10 SEER, 3--PHASE COMMERCIAL PACKAGE GAS ELECTRIC UNITS 3THRU5TONS CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT 3 THRU 5 TON, THREE PHASE Efficiency: - 10 SEER.

More information

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0804 L2 Revised 05 05 2008 G71MPP G71MPP SERIES UNITS G71MPP series units are high efficiency multi position (upflow, downflow, horizontal right and left) gas furnaces equipped

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw] PC SERIES 50 Hertz Self-Contained Packaged Air Conditioners 4 and 5 Ton [14.1 kw to 17.6 kw] Nominal Cooling Capacity: 48,000 to 60,000 BTUH The PC 50 Hz self-contained packaged air conditioners are designed

More information

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING SOUND REFRIGERANT ENVIRONMENTALLY PAN5 Product Specifications 15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R--410A refrigerant

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

CBX32MV WARNING CAUTION. Service Literature CBX32MV (R410A) SERIES UNITS

CBX32MV WARNING CAUTION. Service Literature CBX32MV (R410A) SERIES UNITS Service Literature Corp. 0206 L3 Revised 02 2006 CBX32MV (R410A) SERIES UNITS CBX32MV The CBX32MV is a high efficiency residential split system blower/coil featuring a variable speed motor controlled by

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS PRODUCT SPECIFICATIONS CONDITIONERS TS T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ Bulletin No. TSA-072-240 (11/2016) 072-090 Models 180-240 Models 120-150 Models EER up to 11.7 6 to 20 Tons Cooling Capacity

More information

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986 ENGINEERING DATA CB18 SERIES UP-FLOW CBS18 SERIES HORIZONTAL 2 To 5 Ton (7 To 18 kw) Nominal Cooling Capacity 7200 To 102 400 Btuh (2.1 To 30.0 kw) Optional Electrical Heat ENGINEERING DATA COILS MATCHED

More information

TSA WARNING. Service Literature TSA SERIES UNITS. 6, 7.5, 10, 12.5, 15 & 20 ton

TSA WARNING. Service Literature TSA SERIES UNITS. 6, 7.5, 10, 12.5, 15 & 20 ton Service Literature Corp. 0903 L1 Revised: March 2011 TSA SERIES UNITS TSA 6, 7.5, 10, 12.5, 15 & 20 ton The TSA units are designed for light commercial applications, with a remotely located blower coil

More information

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS 072, 090, 120, 180 & 240 MODELS C SERIES P SERIES HEAT PUMPS SPLIT L SERIES SYSTEMS LSA Condensing Units 6 Thru 20 Ton (21.1 Thru 70.3 ) Heat Pumps 7.5 & 10 Ton (26.4 & 35.2 ) Bulletin #210164 February

More information

UNIT INFORMATION Corp L10 Replaces Corp L4 10HP SERIES UNITS

UNIT INFORMATION Corp L10 Replaces Corp L4 10HP SERIES UNITS SERVICE UNIT INFORMATION Corp. 9427 L10 Replaces Corp. 9329 L4 10HP SERIES UNITS 10HP Litho U.S.A. The 10HP is a high-efficiency residential This manual is divided into sections which discuss the split-system

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

KGA/KGB UNITS WARNING

KGA/KGB UNITS WARNING Service Literature Corp. 00-L8 Revised 05/08 KGA/KG09 through 50 KGA/KG UNITS 7.5 to.5 ton 6. to 4 kw The KGA/KG 7.5, 8.5, 0 and.5 ton (09, 0, 0, 50) packaged gas units are available in standard cooling

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0

More information

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAD3 Product Specifications 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION CONDITIONERS DRY CHARGE UNITS PRODUCT SPECIFICATIONS Bulletin No. 20636 May 204 Supersedes March 202.5 to 5 Tons MODEL NUMBER IDENTIFICATION L C S 3 DC - 036-230 - 2 Lennox Minor Revision Number Air Conditioner

More information

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS 48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,

More information

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons 007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),

More information

T CLASS ROOFTOP UNITS 60HZ Bulletin No July 2008 Supersedes August 2007

T CLASS ROOFTOP UNITS 60HZ Bulletin No July 2008 Supersedes August 2007 E N G I N E E R I N G D A T A P A C K A G E D h e a t p u m p th T CLASS ROOFTOP UNITS 60HZ Bulletin No. 210418 July 2008 Supersedes August 2007 ASHRAE 90.1 COMPLIANT 15 to 20 Tons Net Cooling 182,000

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS AIR CONDITIONERS EL6XC ELITE Series R-40A Bulletin No. 20833 July 208 Supersedes March 208 SEER up to 7.90.5 to 5 Tons Cooling Capacity - 7,800 to 60,000 Btuh MODEL NUMBER IDENTIFICATION

More information

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium

More information

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

More information

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 1029 L7 SLP98UHV SLP98UHV SERIES UNITS SLP98UHV series units are high efficiency upflow, horizontal right and left) gas furnaces equipped with variable capacity gas valve, variable

More information

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS AIR CONDITIONERS 13ACXN MERIT Series R-410A Bulletin No. 210831 January 2018 Supersedes Bulletin No. 210739 SEER up to 15.50 1.5 to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS T CLASS TPA Series HEAT PUMPS 7.5 TO 10 TONS 506148 01 12/08 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT The Clean Air Act of 1990 bans the intentional

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

T S A 048 S 4 N 4 1 T

T S A 048 S 4 N 4 1 T E N G I N E E R I N G D ATA A I R C O N D I T I O N E R S TS T-Class Split System Units R-40A - 50 HZ Bulletin No. 49035 September 2009 MODEL NUMBER IDENTIFICATION Nominal Capacity - 7 to 7.6 kw (2 to

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

MERIT SERIES Up Flow / Horizontal

MERIT SERIES Up Flow / Horizontal A I R H A N D L E R S CB26UH / CBX26UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D A T A Bulletin No. 210429 December 2006 Supersedes November 2006 Nominal Capacity 1.5 to 5 Tons Optional

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

13ACX. IMPORTANT Operating pressures of this R 410A unit are higher than pressures in R 22 units. Always use service equipment rated for R 410A.

13ACX. IMPORTANT Operating pressures of this R 410A unit are higher than pressures in R 22 units. Always use service equipment rated for R 410A. Service Literature Corp. 0612 L2 Revised 07 2006 13ACX SERIES UNITS 13ACX The 13ACX is a high efficiency residential split system condensing unit, which features a scroll compressor and designed for R

More information

T P A 120 S 4 S N 1 Y

T P A 120 S 4 S N 1 Y PRODUCT SPECIFICATIONS HEAT PUMP OUTDOOR UNITS TP T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ Bulletin No. TPA-090-120 (11/2012) EER up to 11.0 7.5 to 10 Tons Cooling Capacity - 89,000 to 180,000 Btuh Heating

More information

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

Specially Designed. SilentComfort Fan Guard. Visit us at   For the latest technical information, ENGINEERING DATA Heavy Gauge Steel Cabinet With Powder Paint Finish Lennox System Operation Monitor (LSOM) Specially Designed SilentComfort Fan Guard CONDITIONERS HSXA19 DAVE LENNOX SIGNATURE COLLECTION

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS T CLASS TPA Series 7.5 AND 10 TON HEAT PUMPS 7.5 TO 10 TONS 506148 01 10/2011 Supersedes 06/11 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT The Clean

More information

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION AIR CONDITIONERS 2scu3 PRODUCT SPECIFICATIONS Dry Charge Split System - 60 HZ Bulletin No. 20644 May 204 Supersedes September 203 3 to 5 Tons MODEL NUMBER IDENTIFICATION 2 scu 3 lc 36 t - a Refrigerant

More information

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016 PA C KA G E D H E AT P U M P LRP4HP Residential - R-40A Bulletin No. 07 November 06 P R O D U C T S P E C I F I C AT I O N S Supersedes October 06 SEER - 4.00 HSPF - 8.00 to 5 Tons Cooling Capacity -,600

More information

Model 655A Sizes

Model 655A Sizes Bryant Air Conditioning SINGLE PACKAGE HEAT PUMP S Model 655A Sizes 018-060 1 1 2 to 5 Tons DESCRIPTION Model 655A is our latest generation of packaged heat pumps for manufactured housing, residential,

More information

MODELS B1PA024, 030 AND 036

MODELS B1PA024, 030 AND 036 STELLAR 2000 SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 511.26-N1Y (892) 511.26-N1Y (893) MODELS B1PA024, 030 AND 036 035-11622 GENERAL YORK Model B1PA units are factory assembled heat

More information

PHD3. Product Specifications

PHD3. Product Specifications SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, 7.7 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS 48GS(N)018-060 STANDARD EFFICIENCY 48GX(N)024-060 HIGH-EFFICIENCY 48GS(N)-2SB SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION

More information

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE Service Facts Customer Property: Contains wiring and service information. Please retain. WC*240-SF-1H Library Service Literature Product Section Unitary Product Package Air Conditioner Model WC* Literature

More information

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ) Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper

More information

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0204 L2 Revised 11 2006 G60UH(X) G60UH(X) SERIES UNITS G60UH(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FOR COMBINATION HEATING AND COOLING ROOFTOP UNITS RKKB SERIES 7.5, 8.5, 10, 12.5 & 15 TON [26.4, 29.9, 35.2 44 & 52.8 kw] RKMB SERIES 7.5, 8.5, 10 & 12.5 TON [26.4, 29.9, 35.2

More information

SKYPAK II Heating & Cooling Self Contained Packages

SKYPAK II Heating & Cooling Self Contained Packages SKYPAK II Heating & Cooling Self Contained Packages SKYPAK II gives you a complete airconditioning and heating system as an all-in-one package unit. Designed for conventional through-the-wall installation

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S A I R C O N D I T I O N E R S XC16 ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology E N G I N E E R I N G D A T A Bulletin No. 210465 May 2006 SEER up to 16.50 2 to 5 Tons Cooling Capacity

More information

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A PA C KA G E D E L E C T R I C / E L E C T R I C LRP4AC Residential - R-40A Bulletin No. 079 July 08 P R O D U C T S P E C I F I C AT I O N S Supersedes Janury 08 SEER - 4.00 to 5 Tons Cooling Capacity

More information

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON 7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

HSXA15 HSXB15. IMPORTANT Operating pressures of this R410A unit are higher than pressures in R22 units. Always use service equipment rated for R410A.

HSXA15 HSXB15. IMPORTANT Operating pressures of this R410A unit are higher than pressures in R22 units. Always use service equipment rated for R410A. Service Literature Corp. 0128 L12 Revised 10 2004 HSXB15 & HSXB15 SERIES UNITS The and HSXB15 are high efficiency residential split system condensing units, which features a scroll compressor and R410A

More information

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ E3FB090/E1FB120/F3EH090 & 120 7-1/2 & 10 NOMINAL TONS (60 HZ) 7 & 9 NOMINAL TONS (50 HZ) (9.0-9.2 EER) 208/230/460 VOLT ONLY 208/230 VOLT ONLY DESCRIPTION YORK has

More information

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S E N G I N E E R I N G D A T A H E A T P U M P O U T D O O R U N I T S 14HPX MERIT SERIES R 410A Bulletin No. 210492 April 2008 Supersedes April 2007 SEER up to 15.0 1.5 to 5 Tons Capacity 19,100 to 59,000

More information

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8 Service Facts Split System Cooling 4TTB3048D1000B, 4TTB3060D1000B CAUTION IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain

More information

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000

More information

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed

More information

50TM COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS 50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Data XR 13 4TWR3018-060 1½ 5 Tons PUB. NO. 22-1795-06 Features and Benefits Climatuff compressor All aluminum Spine Fin coil Quick-Sess cabinet, service access and refrigerant

More information

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN Service Facts Split System Cooling 4TTB3030D1000A IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit. Please

More information

36,000-62,000 BTUH Nominal Capacity

36,000-62,000 BTUH Nominal Capacity 36,000-62,000 BTUH Nominal Capacity STANDARD EQUIPMENT 2TEE3F62A, 4TEE3F62B VARIABLE SPEED AIR HANDLER Ships horizontal - converts to vertical by standing on end. Six-way convertibility-horizontal (left

More information