Operation manual. Split system air conditioners FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B. Operation manual Split system air conditioners

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Operation manual. Split system air conditioners FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B. Operation manual Split system air conditioners"

Transcription

1 FDXM5F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B English

2 Table of Contents Table of Contents About the system INFORMATION 1 About this document About the system.1 Components... 3 Operation Operation range Energy saving and optimum operation 4 5 Maintenance and service Overview: Maintenance and service To clean the drain pan Cleaning the air filter, suction grille, air outlet and outside panels To clean the air outlet and outside panels To clean the air filter Maintenance before a long stop period Maintenance after a long stop period Troubleshooting Symptoms that are NOT system malfunctions Symptom: The system does not operate Symptom: White mist comes out of a unit ( unit) Symptom: Dust comes out of the unit Symptom: The units can give off odours Symptom: The operation stopped suddenly (Operation lamp is on) Symptom: The outdoor fan rotates while the air conditioner is not in operation Symptom: The heating operation stops suddenly and a flowing sound is heard Disposal 7 This appliance is intended to be used by expert or trained users in shops, in light industry, and on farms, or for commercial and household use by lay persons. INFORMATION The sound pressure level is less than 70 dba. : FLAMMABLE MATERIAL The R3 refrigerant (if applicable) in this unit is mildly flammable. (a) (a) Refer to the outdoor unit specifications for the type of refrigerant to be used. Do not modify, disassemble, remove, reinstall or repair the unit yourself as incorrect dismantling or installation may cause an electric shock or fire. Contact your dealer. In case of accidental refrigerant leaks, make sure there are no naked flames. The refrigerant itself is entirely safe and non-toxic. R410A is a non-combustible refrigerant, and R3 is a mildly flammable refrigerant, but they will generate a toxic gas when they accidentally leak into a room where combustible air from fan heaters, gas cookers, etc. is present. Always have qualified service personnel confirm that the point of leakage has been repaired or corrected before resuming operation. Ask your dealer to install and reinstall the air conditioner. Incomplete installation may result in a water leakage, electric shock, and fire. 1 About this document Thank you for purchasing this product. Please: Read the documentation carefully before operating the user interface to ensure the best possible performance. Keep the documentation for future reference. Target audience End users Documentation set This document is part of a documentation set. The complete set consists of: Improper installation or attachment of equipment or accessories could result in electric shock, short-circuit, leaks, fire or other damage to the equipment. Only use accessories, optional equipment and spare parts made or approved by Daikin..1 Components INFORMATION The following illustration is an example and might NOT match your system layout. General safety precautions: Safety instructions that you must read before operating your system Format: Paper (in the box of the indoor unit) : Operation instructions Format: Paper (in the box of the indoor unit) Latest revisions of the supplied documentation may be available on the regional Daikin website or via your installer. The original documentation is written in English. All other languages are translations.

3 3 Operation d 3 Operation 3.1 Operation range e For combination with R410A outdoor unit, refer to the following table: a a b c d e f g h c g f unit unit User interface Air inlet Air outlet Refrigerant piping and electric wiring Drain pipe Earth wire to ground outdoor unit to prevent electric shocks. Do not insert fingers, rods or other objects into the air inlet or outlet. Do not remove the fan guard. When the fan is rotating at high speed, it will cause injury. Never touch the internal parts of the controller. Do not remove the front panel. Some parts inside are dangerous to touch and appliance problems may happen. For checking and adjusting the internal parts, contact your dealer. Do not wipe the controller operation panel with benzine, thinner, chemical dust cloth, etc. The panel may get discoloured or the coating peeled off. If it is heavily dirty, soak a cloth in water-diluted neutral detergent, squeeze it well and wipe the panel clean. Wipe it with another dry cloth. Never press the button of the user interface with a hard, pointed object. The user interface may be damaged. Never pull or twist the electric wire of the user interface. It may cause the unit to malfunction. b h units Cooling Heating RR71~15 RQ71~15 RXS5~60 MXS50 3MXS40~68 4MXS68~80 5MXS90 RZQG71~140 RZQSG71~140 RZQ00~50 15~46 C DB 18~37 C DB 1~8 C WB 5~46 C DB 18~37 C DB 1~8 C WB 10~46 C DB 18~3 C DB 10~46 C DB 18~3 C DB 10~46 C DB 18~3 C DB 15~50 C DB 18~37 C DB 1~8 C WB 15~46 C DB 0~37 C DB 14~8 C WB 5~46 C DB 0~37 C DB 14~8 C WB 9~1 C DB 10~15 C WB 19~1 C DB 0~15.5 C WB 14~1 C DB 15~15.5 C WB 14~1 C DB 15~15 C WB For combination with R3 outdoor unit, refer to the following table: units Cooling Heating MXM50 3MXM40~68 4MXM68~80 5MXM90 RXM5~60 RZAG71~140 10~46 C DB 18~3 C DB 10~46 C DB 18~3 C DB 0~5 C DB 18~37 C DB 1~8 C WB 19.5~1 C DB 0~15.5 C WB 3

4 4 Energy saving and optimum operation units Cooling Heating RZASG71~140 humidity (a) 15~46 C DB 0~37 C DB 14~8 C WB 80% (a) 14~1 C DB 15~15.5 C WB To avoid condensation and water dripping out of the unit. If the or the humidity is beyond these conditions, safety devices may be put in action and the air conditioner may not operate. 4 Energy saving and optimum operation Never expose little children, plants or animals directly to the air flow. Do NOT place objects below the indoor and/or outdoor unit that may get wet. In this condition, condensation on the main unit or refrigerant pipes, air filter dirt or drain blockage may cause dripping. This results in fouling or failure of the object which is located beneath the unit. Do not use the system for other purposes. In order to avoid any quality deterioration, do not use the unit for cooling precision instruments, food, plants, animals or works of art. Do not operate the system when using a room fumigationtype insecticide. This could cause the chemicals to become deposited in the unit, which could endanger the health of those who are hypersensitive to chemicals. Do not place a flammable spray bottle near the air conditioner and do not use sprays. Doing so may result in a fire. Observe the following precautions to ensure the system operates properly. Prevent direct sunlight from entering a room during cooling operation by using curtains or blinds. Ventilate often. Extended use requires special attention to ventilation. Keep doors and windows closed. If the doors and windows remain open, air will flow out of your room causing a decrease in the cooling or heating effect. Be careful not to cool or heat too much. To save energy, keep the setting at a moderate level. Never place objects near the air inlet or the air outlet of the unit. It may cause deterioration in the effect or stop the operation. Turn off the main power supply switch to the unit when the unit is not used for longer periods of time. If the switch is on, it consumes electricity. Before restarting the unit, turn on the main power supply switch 6 hours before operation to ensure smooth running. Condensation may form if the humidity is above 80% or if the drain outlet gets blocked. Adjust the room properly for a comfortable environment. Avoid excessive heating or cooling. Notice that it may take some time for the room to reach the set. Consider using the timer setting options. Adjust the air flow direction to avoid cool air from gathering on the floor or warm air against the ceiling. (Up during cooling or dry operation to the ceiling and down during heating operation.) Avoid direct air flow to room inhabitants. 5 Maintenance and service 5.1 Overview: Maintenance and service The installer has to perform a yearly maintenance. Refrigerant This product contains fluorinated greenhouse gases. Do NOT vent gases into the atmosphere. Refrigerant type: R3 Global warming potential (GWP) value: 675 Refrigerant type: R410A Global warming potential (GWP) value: In Europe, the greenhouse gas emissions of the total refrigerant charge in the system (expressed as tonnes CO -equivalent) is used to determine the maintenance intervals. Follow the applicable legislation. Formula to calculate the greenhouse gas emissions: GWP value of the refrigerant Total refrigerant charge [in kg] / 1000 Please contact your installer for more information. Maintenance must be done by an authorised installer or service agent. We recommend to do maintenance at least once a year. However, applicable legislation might require shorter maintenance intervals. Before accessing terminal devices, make sure to interrupt all power supply. DANGER: RISK OF ELECTROCUTION To clean the air conditioner or air filter, be sure to stop operation and turn all power supplies off. Otherwise, an electric shock and injury may result. To prevent electric shocks or fire: Do NOT rinse the unit. Do NOT operate the unit with wet hands. Do NOT place any objects containing water on the unit. After a long use, check the unit stand and fitting for damage. If damaged, the unit may fall and result in injury. 4

5 5 Maintenance and service Do not touch the heat exchanger fins. These fins are sharp and could result in cutting injuries. Clean the air filter. Use a vacuum cleaner or wash with water. If the air filter is very dirty, use a soft brush and neutral detergent. When cleaning the heat exchanger, make sure to remove the switch box and fan motor. Water or detergent might deteriorate the insulation of electronic components and result in burnout of these components. Be carefull with ladders when working in high places. 5. To clean the drain pan Clean the drain pan so that it does NOT become clogged and dusty. 5.3 Cleaning the air filter, suction grille, air outlet and outside panels To clean the air outlet and outside panels Do NOT let the indoor unit get wet. Possible consequence: Electric shock or fire. Do NOT use gasoline, benzene, thinner polishing powder or liquid insecticide. Possible consequence: Discoloration and deformation. Do NOT use water or air of 50 C or higher. Possible consequence: Discoloration and deformation. Do NOT scrub firmly when washing the blade with water. Possible consequence: The surface sealing peels off. Clean with a soft cloth. If it is difficult to remove stains, use water or neutral detergent To clean the air filter When to clean the air filter: Rule of thumb: Clean every 6 months. If the air in the room is extremely contaminated, increase the cleaning frequency. Depending on the settings, the user interface can display the TIME TO CLEAN AIR FILTER notification. Clean the air filter when the notification is displayed. If the dirt becomes impossible to clean, change the air filter (= optional equipment). How to clean the air filter: 1 Remove the air filter. Push the hooks and pull the filter as shown in illustration below. ( hooks for 5 and 35 type or 3 hooks for 50 and 60 type) rear suction 1 bottom suction 1 3 Dry the air filter in the shadow. 4 Reattach the air filter. Hook the filter behind the flap and attach the filter to the main unit while pushing down on the hooks. rear suction 1 5 Turn ON the power. 6 Press the FILTER SIGN RESET button. bottom suction Result: The TIME TO CLEAN AIR FILTER notification disappears from the user interface. 5.4 Maintenance before a long stop period E.g., at the end of the season. Let the indoor units run in fan only operation for about half a day in order to dry the interior of the units. Turn off the power. The user interface display disappears. When the main power is turned on, the air conditioner will use some power, even if it is not operating. Clean air filters and casings of indoor units. Contact your installer or maintenance person to clean air filters and casings of the indoor unit. Maintenance tips and procedures for cleaning are provided in the installation/operation manuals of dedicated indoor units. Make sure to install cleaned air filters back in the same position. Remove the batteries from the user interface. 5.5 Maintenance after a long stop period E.g., at the beginning of the season. Check and remove everything that might be blocking inlet and outlet vents of indoor units and outdoor units. Check if the earth is connected properly. Check if there is somewhere a broken wire. Contact your dealer in case of problems. Clean air filters and casings of indoor units. Contact your installer or maintenance person to clean air filters and casings of the indoor unit. Maintenance tips and procedures for cleaning are provided in the installation/operation manuals of dedicated indoor units. Make sure to install cleaned air filters back in the same position. 1 5

6 6 Troubleshooting Turn on the power at least 6 hours before operating the unit in order to ensure smoother operation. As soon as the power is turned on, the user interface display appears. 6 Troubleshooting If one of the following malfunctions occur, take the measures shown below and contact your dealer. Stop operation and shut off the power if anything unusual occurs (burning smells etc.). Leaving the unit running under such circumstances may cause breakage, electric shock or fire. Contact your dealer. The system must be repaired by a qualified service person: If the system does not properly operate except for the above mentioned cases and none of the above mentioned malfunctions is evident, investigate the system according to the following procedures. Malfunction If the system does not operate at all. The system operates, but cooling or heating is insufficient. Measure Check if there is no power failure. Wait until power is restored. If power failure occurs during operation, the system automatically restarts immediately after power is restored. Check if no fuse has blown or breaker is activated. Change the fuse or reset the breaker if necessary. Are batteries set in the remote controller? Is the timer setting correct? Check if air inlet or outlet of outdoor or indoor unit is not blocked by obstacles. Remove any obstacles and make sure the air can flow freely. Check if the air filter is clogged. Contact your dealer to clean the air filter. Check the setting. Refer to the manual of the user interface. Check if the air flow angle is proper. Refer to the manual of the user interface. Check the fan speed setting is set to low speed. Refer to the manual of the user interface. Check for open doors or windows. Close doors and windows to prevent wind from coming in. Check if direct sunlight enters the room. Use curtains or blinds. If the heat source of the room is excessive (when cooling). Cooling effect decreases if heat gain of the room is too large. Check if there are too many occupants in the room during cooling operation. Check if the heat source of the room is excessive. Malfunction Operation stops suddenly. (Operation lamp blinks.) An abnormal function happens during operation. Measure Check if the air filter is clogged. Contact your dealer to clean the air filter (refer to "Maintenance" in the indoor unit manual). Check if air inlet or outlet of outdoor or indoor unit is not blocked by obstacles. Remove any obstacles, turn the breaker OFF and back ON. If the lamp still blinks, contact your dealer. Check if all indoor units connected to outdoor unit in the multi-system are operating in the same mode. The air conditioner may malfunction because of lightning or radio waves. Turn the breaker OFF and back ON. If after checking all above items, it is impossible to fix the problem yourself, contact your installer and state the symptoms, the complete model name of the unit (with manufacturing number if possible) and the installation date (possibly listed on the warranty card). 6.1 Symptoms that are NOT system malfunctions The following symptoms are NOT system malfunctions: Symptom: The system does not operate The air conditioner does not start immediately after the ON/OFF button on the user interface is pressed. If the operation lamp lights, the air conditioner is in normal condition. It does not restart immediately because one of its safety devices actuates to prevent the air conditioner from being overloaded. The air conditioner will turn on again automatically after 3 minutes. The air conditioner does not start immediately after the power supply is turned on. Wait 1 minute until the microcomputer is prepared for operation. The air conditioner does not restart immediately when the setting button is returned to its former position after pushing. It does not restart immediately because one of its safety devices actuates to prevent the air conditioner from being overloaded. The air conditioner will turn on again automatically after 3 minutes. The outdoor unit has stopped. This is because the room has reached the set. The unit switches to fan operation. " " (external control icon) is displayed on the user interface and the actual operation is different from the user interface setting. For multi-split models, the microcomputer executes the following control depending on the operation mode of other indoor units. The fan speed is different from the setting. Pressing the fan speed control button does not change the fan speed. When the room reaches the set in heating mode or the unit s maximum capacity is reached, the outdoor unit will stop operation and the indoor unit will operate in fan only mode (low fan speed). In case of multi-split, the indoor unit alternately operates in fan stop mode and fan only mode (LL= low fan speed). This is to prevent the cool air from being blown directly onto anyone present in the room Symptom: White mist comes out of a unit ( unit) When humidity is high during cooling operation (in oily and dusty places). If the interior of an indoor unit is extremely contaminated, the distribution inside a room becomes uneven. It is 6

7 7 Disposal necessary to clean the interior of the indoor unit. Ask your dealer for details on cleaning the unit. This operation requires a qualified service person. When the air conditioner is changed over to heating operation after defrost operation. Moisture generated by defrost becomes steam and exits Symptom: Dust comes out of the unit When the unit is used for the first time in a long time. This is because dust has gotten into the unit Symptom: The units can give off odours The unit can absorb the smell of rooms, furniture, cigarettes, etc., and then emit it again Symptom: The operation stopped suddenly (Operation lamp is on) The air conditioner may stop for system protection due to large voltage fluctuation. It automatically resumes operation after about 3 minutes Symptom: The outdoor fan rotates while the air conditioner is not in operation After operation has stopped. The outdoor fan continues to rotate for another 30 seconds for system protection. While the air conditioner is not in operation. When the outdoor is very high, the outdoor fan starts to rotate for system protection Symptom: The heating operation stops suddenly and a flowing sound is heard The system is removing frost on the outdoor unit. You should wait for about 3 to 8 minutes. 7 Disposal Dismantling of the unit, and treatment of the refrigerant, oil and other parts must comply with the applicable legislation. 7

8 Copyright 017 Daikin 4P

OPERATION MANUAL. SYSTEM Inverter Air Conditioners FXSQ36MVJU FXMQ36MVJU FXSQ48MVJU. MODELS Ceiling-mounted Duct type. Ceiling-mounted Built-in type

OPERATION MANUAL. SYSTEM Inverter Air Conditioners FXSQ36MVJU FXMQ36MVJU FXSQ48MVJU. MODELS Ceiling-mounted Duct type. Ceiling-mounted Built-in type OPERATION MANUAL SYSTEM Inverter Air Conditioners MODELS Ceiling-mounted Duct type FXMQ30MVJU FXMQ36MVJU FXMQ48MVJU Ceiling-mounted Built-in type FXSQ12MVJU FXSQ18MVJU FXSQ24MVJU FXSQ30MVJU FXSQ36MVJU

More information

SYSTEM Inverter Air Conditioners

SYSTEM Inverter Air Conditioners OPERATION MANUAL SYSTEM Inverter Air Conditioners MODEL Ceiling-mounted duct type low static pressure unit FXDQ07MVJU FXDQ09MVJU FXDQ12MVJU FXDQ18MVJU FXDQ24MVJU Read these instructions carefully before

More information

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER Owner s Manual Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 IMPORTANT NOTE: Read this manual carefully before installing

More information

CDKD25CVM CDKD35CVM Operation Manual

CDKD25CVM CDKD35CVM Operation Manual 00_CV_3P196326-2.fm Page 1 Thursday, December 7, 2006 1:38 PM DAIKIN ROOM AIR CONDITIONER MODELS CDKD25CVM CDKD35CVM Operation Manual CDKD50CVM CDKD60CVM English Portugues CONTENTS READ BEFORE OPERATION

More information

Inverter Split-type Room Air Conditioner

Inverter Split-type Room Air Conditioner OWNER S MANUAL Inverter Split-type Room Air Conditioner Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.

More information

Bosch Split-Type Ductless Air Conditioner / Heat Pump

Bosch Split-Type Ductless Air Conditioner / Heat Pump Bosch Split-Type Ductless Air Conditioner / Heat Pump Climate 5000 AA Series User Manual 2 Bosch Split Type Ductless Air Conditioner / Heat Pump User Manual Data subject to change 01.2017 Bosch Thermotechnology

More information

OPERATION MANUAL. System air conditioner

OPERATION MANUAL. System air conditioner OPERATION MANUAL System air conditioner MODEL REYQ72TTJU REYQ96TTJU REYQ120TTJU REYQ144TTJU REYQ168TTJU REYQ192TTJU REYQ216TTJU REYQ240TTJU REYQ264TTJU REYQ288TTJU REYQ312TTJU REYQ336TTJU REYQ360TTJU REYQ384TTJU

More information

Owner s Manual CS

Owner s Manual CS Owner s Manual IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference. CS78421-548-754 Table of Contents

More information

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

Utopian Split A/C. Thank you for purchasing this quality Split A/C system! Utopian Split A/C Thank you for purchasing this quality Split A/C system! Please read through this manual completely, and keep it in case you need to reference the information in the future. Any operation

More information

OPERATION MANUAL. MODELS (Ceiling-mounted Multi flow Cassette type) FFQ25BV1B FFQ35BV1B FFQ50BV1B FFQ60BV1B

OPERATION MANUAL. MODELS (Ceiling-mounted Multi flow Cassette type) FFQ25BV1B FFQ35BV1B FFQ50BV1B FFQ60BV1B OPERATION MANUAL SPLIT SYSTEM Air Conditioner MODELS (Ceiling-mounted Multi flow Cassette type) FFQ25BV1B FFQ35BV1B FFQ50BV1B FFQ60BV1B [1] 1 3 4 2 TEST C hr hr TEST NOT AVAILABLE L H 2 10 11 3 1 4 5 6

More information

MODELS FTX20J2V1B FTX25J2V1B FTX35J2V1B FTX20J3V1B FTX25J3V1B FTX35J3V1B DAIKIN ROOM AIR CONDITIONER. Operation Manual

MODELS FTX20J2V1B FTX25J2V1B FTX35J2V1B FTX20J3V1B FTX25J3V1B FTX35J3V1B DAIKIN ROOM AIR CONDITIONER. Operation Manual DAIKIN ROOM AIR CONDITIONER Operation Manual MODELS FTX20J2V1B FTX25J2V1B FTX35J2V1B FTX20J3V1B FTX25J3V1B FTX35J3V1B CONTENTS READ BEFORE OPERATION Safety precautions... 2 Names of parts... 4 Preparation

More information

ROOM AIR CONDITIONER. Read This Manual. Before using your air conditioner, please read this manual carefully and keep it for future reference.

ROOM AIR CONDITIONER. Read This Manual. Before using your air conditioner, please read this manual carefully and keep it for future reference. Before using your air conditioner, please read this manual carefully and keep it for future reference. SPLIT- TYPE ROOM AIR CONDITIONER Read This Manual Inside you will find many helpful hints on how to

More information

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type) OPERATION MANUAL (Ceiling mounted duct type) VAM50FC VAM500FC VAM650FC VAM800FC VAM000FC VAM500FC VAM000FC 8 7 6 9 5 7 5 0 6 8 6 9 0 5 5 7 7 6 7 A A B B 5 6 5 6 7 VAM50F VAM800F VAM500F VAM500F VAM000F

More information

OPERATION MANUAL DAIKIN ROOM AIR CONDITIONER MODELS

OPERATION MANUAL DAIKIN ROOM AIR CONDITIONER MODELS English DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL Français Español Enjoy year-roun nd comfort. MODELS FTX09NMVJU FTX12NMVJU FTX15NMVJU FTX18NMVJU FTX24NMVJU FTXN09NMVJU FTXN12NMVJU FTXN18NMVJU FTXN24NMVJU

More information

FLOOR & CEILING SERIES

FLOOR & CEILING SERIES USE'S FLOO & CEIL SEIES ASF-0A ES air flow for a long o not insert fingers rods or other objects into the air When the fan is rotating at high speed it will cause injury. IPO SAFE IFOIO... POA S... IIOE

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE AIR CONDITIONER INDOOR UNIT/OUTDOOR UNIT MODEL RAS-260GA/RAC-260GA RAS-350GA/RAC-350GA OUTDOOR UNIT INDOOR UNIT RAC-260GA RAS-260GA RAS-350GA RAC-350GA Instruction manual Page 1~24 To obtain

More information

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner alleru-buster F566894 Operating Instructions Air Conditioner Indoor Unit CS-RE9JKR CS-RE1JKR Outdoor Unit CU-RE9JKR CU-RE1JKR ENGLISH ~ 7 Before operating the unit, read these operating instructions thoroughly

More information

R410A SPLIT SERIES DC INVERTER QUICK COUPLING

R410A SPLIT SERIES DC INVERTER QUICK COUPLING R40A SPLIT SERIES DC INVERTER QUICK COUPLING Models ECO906SQ ECO206SQ ECO806SQ Read This Manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a

More information

OPERATION MANUAL. Wireless Remote Controller Kit

OPERATION MANUAL. Wireless Remote Controller Kit OPERATION MANUAL Wireless Remote Controller Kit MODELS: BRC7F632F English Thank you for purchasing this Daikin air conditioner. Carefully read this operation manual before using the air conditioner. It

More information

OPERATION MANUAL FAQ18PVJU FAQ24PVJU. MODELS (Wall mounted type)

OPERATION MANUAL FAQ18PVJU FAQ24PVJU. MODELS (Wall mounted type) OPERATION MANUAL SPLIT SYSTEM Air Conditioner MODELS (Wall mounted type) FAQ18PVJU FAQ24PVJU English Français Read these instructions carefully before installation. Keep this manual in a handy place for

More information

MODELS ATX20KV1B ATX25KV1B ATX35KV1B

MODELS ATX20KV1B ATX25KV1B ATX35KV1B DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL Enjoy year-round comfort. MODELS ATX20KV1B ATX25KV1B ATX35KV1B Features Enhanced comfort and energy savings COMFORT AIRFLOW The airflow direction is upward

More information

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner F566113 Operating Instructions Air Conditioner Indoor Unit CS-E18HKR CS-E1HKR CS-E4HKR CS-E8HKR Outdoor Unit CU-E18HKR CU-E1HKR CU-E4HKR CU-E8HKR Before operating the unit, read these operating instructions

More information

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner Operating Instructions Air Conditioner Ceiling (T2 type) 4-Way Cassette (U1 type) Model No. INDOOR UNIT Ceiling (T2 type) S-60PT2R5A S-71PT2R5A S-100PT2R5A S-125PT2R5A S-140PT2R5A 4-Way Cassette (U1 type)

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE INDOOR UNIT/OUTDOOR UNIT ENGLISH MODEL RAS-70YHA / RAC-70YHA OUTDOOR UNIT INDOOR UNIT RAC-70YHA RAS-70YHA Instruction manual Page 1~23 To obtain the best performance and ensure years of trouble

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE AIR CONDITIONER ENGLISH ENGLI INDOOR UNIT/OUTDOOR UNIT MODEL RAS-DX10CSK/RAC-DX10CSK RAS-DX13CSK/RAC-DX13CSK RAS-DX18CSK/RAC-DX18CSK OUTDOOR UNIT INDOOR UNIT RAS-DX10CSK RAS-DX13CSK RAS-DX18CSK

More information

AH-PNX11 AU-PNX11 AH-PNX14 AU-PNX14 EN-1 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL ENGLISH

AH-PNX11 AU-PNX11 AH-PNX14 AU-PNX14 EN-1 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL ENGLISH SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL ENGLISH INDOOR UNIT OUTDOOR UNIT AH-PNX AU-PNX AH-PNX4 AU-PNX4 Device of this mark is a trademark of Sharp Corporation. Plasmacluster is a registered trademark

More information

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner Operating Instructions Air Conditioner Model No. Indoor Unit CS-EGFEW CS-E8GFEW Outdoor Unit CU-EGFR CU-E8GFR ENGLISH ~ Before operating the unit, read these operating instructions thoroughly and keep

More information

FLOOR-STANDING SPLIT TYPE ROOM AIR CONDITIONER

FLOOR-STANDING SPLIT TYPE ROOM AIR CONDITIONER Before using your air conditioner, please read this manual carefully and keep it for future reference. FLOOR-STANDING SPLIT TYPE ROOM AIR CONDITIONER Read This Manual Inside you will find many helpful

More information

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different. RADS-51J RADS-61J Owner s Manual Room Air Conditioner with R-410A Heat Controller, Inc. 15 16 Contact an authorized service technician for repair or maintenance of this unit. Contact an authorized installer

More information

USER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series

USER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series USER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series ENGLISH FRANÇAIS ESPAÑOL Split - type Air Conditioner (Cooling and Heating) E S F DB98-27559A(1) Contents PREPARATION Safety

More information

DAIKIN ROOM AIR CONDITIONER MODELS FTXS15DVJU FTXS18DVJU FTXS24DVJU. Operation Manual

DAIKIN ROOM AIR CONDITIONER MODELS FTXS15DVJU FTXS18DVJU FTXS24DVJU. Operation Manual DAIKIN ROOM AIR CONDITIONER Operation Manual MODELS TXS15DVJU TXS18DVJU TXS24DVJU CONTENTS READ BEORE OPERATION Safety precautions... 2 Names of parts... 4 Preparation Before Operation... 7 OPERATION AUTO

More information

OPERATION MANUAL. SYSTEM Inverter Air Conditioners

OPERATION MANUAL. SYSTEM Inverter Air Conditioners OPERATION MANUAL SYSTEM Inverter Air Conditioners English Français MODELS Ceiling-mounted Duct type Español FXMQ07PBVJU FXMQ09PBVJU FXMQ12PBVJU FXMQ15PBVJU FXMQ18PBVJU FXMQ24PBVJU FXMQ30PBVJU FXMQ36PBVJU

More information

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9374379224 07H050_cover.p65 2007.8.7, 0:27 AM CONTENTS SAFETY PRECAUTIONS... FEATURES

More information

Compact Cassette Type

Compact Cassette Type Compact Cassette Type PART NO.9374379392-04 CONTENTS SAFETY PRECAUTIONS... 1 FEATURES AND FUNCTIONS... 2 NAME OF PARTS... 3 PREPARATORY OPERATION... 4 OPERATION... 4 TIMER FUNCTIONS... 6 ON/OFF TIMER...

More information

40KMC KMQ

40KMC KMQ 40KMC------301 40KMQ------301 OWNER S MANUAL Split system Global cassette indoor unit IR Remote Control Room Controller Zone Manager The unit can be used with infrared Remote Control, with the Carrier

More information

PORTABLE AIR CONDITIONER (LOCAL)

PORTABLE AIR CONDITIONER (LOCAL) EN PORTABLE AIR CONDITIONER (LOCAL) OPERATING INSTRUCTIONS Read the instructions carefully before operating the appliance or carrying out maintenance work. Observe all the safety instructions; failure

More information

INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER Owner s Manual IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure

More information

RAV-SP181BT-UL RAV-SP241BT-UL RAV-SP301BT-UL RAV-SP361BT-UL RAV-SP421BT-UL

RAV-SP181BT-UL RAV-SP241BT-UL RAV-SP301BT-UL RAV-SP361BT-UL RAV-SP421BT-UL AIR CONDITIONER (SPLIT TYPE) Owner s Manual Indoor Unit Model name: For commercial use Pour usage commercial Concealed Duct Type RAV-SP8BT-UL RAV-SP2BT-UL RAV-SP30BT-UL RAV-SP36BT-UL RAV-SP2BT-UL Owner

More information

AY-AP09DJ SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL AE-A09DJ AY-AP09DJ OUTDOOR UNIT INDOOR UNIT

AY-AP09DJ SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL AE-A09DJ AY-AP09DJ OUTDOOR UNIT INDOOR UNIT R AY-AP09DJ SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL INDOOR UNIT AY-AP09DJ OUTDOOR UNIT AE-A09DJ ENGLISH Thank you for purchasing a SHARP air conditioner. Please read this manual carefully before

More information

SPLIT TYPE

SPLIT TYPE ROOM AIR CONDITIONER SPLIT TYPE OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES Português EλληvIkά Italiano

More information

Owner s Manual TABLE OF CONTENTS

Owner s Manual TABLE OF CONTENTS 40MBDQ Ducted Style Ductless System Sizes 18 to 48 Owner s Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY... 2 GENERAL... 2 PARTS LIST... 3 DISPLAY PANELS... 4 FUNCTION BUTTONS... 5 REMOTE CONTROL...

More information

Coway Air Purifier AP-1008DH

Coway Air Purifier AP-1008DH Coway Air Purifier AP-1008DH This product is for domestic use only.it cannot be used in an overseas country where the power voltage is different. Warranty card is included in this user s manual. Read and

More information

DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXS20K2V1B FTXS25K2V1B CTXS15K2V1B CTXS35K2V1B FTXS20K3V1B FTXS25K3V1B CTXS15K3V1B CTXS35K3V1B

DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXS20K2V1B FTXS25K2V1B CTXS15K2V1B CTXS35K2V1B FTXS20K3V1B FTXS25K3V1B CTXS15K3V1B CTXS35K3V1B DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXS20K2V1B FTXS25K2V1B CTXS15K2V1B CTXS35K2V1B FTXS20K3V1B FTXS25K3V1B CTXS15K3V1B CTXS35K3V1B Feature For your comfort and energy saving INTELLIGENT

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE AIR CONDITIONER INDOOR UNIT/OUTDOOR UNIT ENGLISH MODEL RAS-DX10CFK / RAC-DX10CFK RAS-DX13CFK / RAC-DX13CFK OUTDOOR UNIT INDOOR UNIT RAC-DX10CFK RAC-DX13CFK RAS-DX10CFK RAS-DX13CFK Instruction

More information

PEH-8,10WYB. Air-Conditioners INDOOR UNIT. For use with R410A OPERATION MANUAL

PEH-8,10WYB. Air-Conditioners INDOOR UNIT. For use with R410A OPERATION MANUAL I Air-Conditioners INDOOR UNIT PEH-8,10WYB For use with R410A OPERATION MANUAL For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. Remote controller-button

More information

English. Français DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL. Español MODELS FTX30NVJU FTX36NVJU

English. Français DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL. Español MODELS FTX30NVJU FTX36NVJU English DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL Français Español Enjoy year-roun nd comfort. MODELS FTX30NVJU FTX36NVJU Features Enhanced comfort and energy savings INTELLIGENT EYE The INTELLIGENT

More information

FLOOR-STANDING TYPE AIR CONDITIONER USER'S MANUAL

FLOOR-STANDING TYPE AIR CONDITIONER USER'S MANUAL FLOOR-STANDING TYPE AIR CONDITIONER USER'S MANUAL CONTENTS SOCIABLE REMARK Sociable remark...2 SAFETY PRECAUTIONS Warning...3 Caution...4 Prior to operation...5 OPERATIING INSTRUCTIONS Product overview......6

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE AIR CONDITIONER ENGLISH ENGLISH INDOOR UNIT/OUTDOOR UNIT MODEL RAS-E10CAK/RAC-E10CAK RAS-E13CAK/RAC-E13CAK OUTDOOR UNIT INDOOR UNIT RAC-E10CAK RAS-E10CAK RAS-E13CAK RAC-E13CAK Instruction manual

More information

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36 OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36 TABLE OF CONTENTS PAGE SAFETY PRECAUTIONS... 2 GENERAL... 2 INDOOR UNIT PART NAMES... 3 REMOTE CONTROL PART NAMES...

More information

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump R-10A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFF(A/H)H, DFC(A/H) Please read the operating instructions and safety precautions carefully and thoroughly before installing and

More information

FUJITSU GENERAL LIMITED AIR CONDITIONER FLOOR CONSOLE/ UNDER CEILING DUAL TYPE OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO P/N

FUJITSU GENERAL LIMITED AIR CONDITIONER FLOOR CONSOLE/ UNDER CEILING DUAL TYPE OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO P/N OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO AIR CONDITIONER FLOOR CONSOLE/ UNDER CEILING DUAL TYPE Español Français English KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9359944058

More information

Owner s Manual TABLE OF CONTENTS

Owner s Manual TABLE OF CONTENTS 40MHH High Wall Ductless System Sizes 09 to 24 Owner s Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY... 2 GENERAL... 2 PART NAMES... 3 INDOOR UNIT DISPLAY INDICATOR... 4 REMOTE CONTROL... 4 FUNCTION

More information

Owner s Manual. WAS / WYS Series. 9,000 BTU/h. through 36,000 BTU/h. Inverter+ and Inverter++ Models

Owner s Manual. WAS / WYS Series. 9,000 BTU/h. through 36,000 BTU/h. Inverter+ and Inverter++ Models DUCTLESS MINI SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP WAS / WYS Series WAS: Cooling Only Version WYS: Cooling and Heating Version Inverter+ and Inverter++ Models 9,000 BTU/h. through 36,000 BTU/h. Owner

More information

SPLIT-TYPE ROOM AIR CONDITIONER

SPLIT-TYPE ROOM AIR CONDITIONER Before using your air conditioner please read this manual carefully and keep it for future reference. SPLIT-TYPE ROOM AIR CONDITIONER The design and specifications are subject to change without prior notice

More information

Model No. NR-BU303 Series

Model No. NR-BU303 Series RBD / PGF / GULF Operating Instructions Refrigerator For Household Use Model No. NR-BU303 Series NR-BU343 Series Contents Safety precautions...2 Installation...4 Parts identification...5 Specification...5

More information

K 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

K 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS K 2.97 M High Pressure Washer Operator Manual Overview... 2 Important Precautions... 3-4 Assembly Instructions... 4 Operating Instructions... 5 GFCI Instructions... 6 Using the Accessories... 6 Working

More information

OWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use. Indoor unit 42TVU010, 012, Outdoor unit 38TVU010, 012, ENGLISH

OWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use. Indoor unit 42TVU010, 012, Outdoor unit 38TVU010, 012, ENGLISH OWNER S MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit 4TVU00, 0, 08-70 Outdoor unit 8TVU00, 0, 08-70 0508 PRECAUTIONS FOR SAFETY DANGER Do not install, repair, open or

More information

WIRED REMOTE CONTROLLER

WIRED REMOTE CONTROLLER WIRED REMOTE CONTROLLER OPERATION MANUAL Proper Use for Effective Energy Saving Thank you for purchasing the wired remote controller. This manual describes safety precautions required for the use of the

More information

Owner's Manual TABLE OF CONTENTS

Owner's Manual TABLE OF CONTENTS 40MAQ High Wall Ductless System Sizes 09 to 36 Owner's Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY... 2 GENERAL... 2 PART NAMES... 3 FUNCTION BUTTONS... 4 DISPLAY PANELS... 5 REMOTE CONTROL... 6

More information

Operating Instructions

Operating Instructions Operating Instructions Air Conditioner Model No. Indoor Unit CS-RE9PKR CS-RE12PKR Outdoor Unit CU-RE9PKR CU-RE12PKR Operating Instructions Air Conditioner Thank you for purchasing Panasonic Air Conditioner.

More information

Model K 520 M Part No

Model K 520 M Part No Model K 520 M Part No. 1.069-680.0 High Pressure Washer Operator Manual Overview... 2 Precautions... 2-4 Assembly Instructions... 4 Operating Instructions... 5 Using the Accessories... 6 Working with Detergents...

More information

INSTRUCTIONS Français 2 Nederlands 15 English 28 Italien

INSTRUCTIONS Français 2 Nederlands 15 English 28 Italien INSTRUCTIONS Français 2 Nederlands 15 English 28 Italien 41 INSTRUCTION BOOK Thank you for purchasing our product. Please read this owner s manual carefully before using the unit. It is important that

More information

GUF-50RDH3 GUF-50RD3 GUF-100RDH3 GUF-100RD3

GUF-50RDH3 GUF-50RD3 GUF-100RDH3 GUF-100RD3 Fresh Master ENGLISH Models: GUF-50RDH3 GUF-50RD3 GUF-100RDH3 GUF-100RD3 Operating Instructions (For the user) GUF-50RDH3 shown above. Humidifier function not available on GUF-50RD3 and GUF-100RD3. Contents

More information

ELECTRONIC CONTROL AIR CONDITIONER

ELECTRONIC CONTROL AIR CONDITIONER USE & CARE MANUAL NOTE: This USE & CARE MANUAL provides specific operating instructions for your model. Use the room air conditioner only as instructed in this USE & CARE MANUAL. These instructions are

More information

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner Operating Instructions Air Conditioner Model No. Indoor Unit CS-E7MKR CS-E9MKR CS-EMKR CS-E5MKR CS-E8MKR CS-EMKR CS-E4MKR CS-E8MKR Outdoor Unit CU-E7MKR CU-E9MKR CU-EMKR CU-E5MKR CU-E8MKR CU-EMKR CU-E4MKR

More information

Operating Instructions

Operating Instructions Operating Instructions Juicer (Household Use) 12 00 fl 7 0 2 12 00 7 0 2 fl TABLE OF CONTENTS SAFETY PRECAUTIONS... 2-4 PART NAMES... 5 DISASSEMBLY... 6 CIRCUIT BREAKER PROTECTION... 6 HOW TO USE... 7

More information

ULTRA LOW TEMPERATURE FREEZER. User Manual

ULTRA LOW TEMPERATURE FREEZER. User Manual ULTRA LOW TEMPERATURE FREEZER User Manual Note:Kaltis reserves the right to modify any parts of this manual without prior notice. 1. No part of this manual may be reproduced in any form, or translated

More information

Owner s Manual. Oasis Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER

Owner s Manual. Oasis Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER SPLIT-TYPE ROOM AIR CONDITIONER Owner s Manual Oasis Series All Model Numbers IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save

More information

SOPHIA HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM OWNER'S MANUAL. Models: CH-S30FTXW-SV (230V) CH-S36FTXW-SV (230V)

SOPHIA HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM OWNER'S MANUAL. Models: CH-S30FTXW-SV (230V) CH-S36FTXW-SV (230V) SOPHIA HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM OWNER'S MANUAL Models: CH-S30FTXW-SV (230V) CH-S36FTXW-SV (230V) IMPORTANT NOTE: Read this manual carefully before installing or operating your

More information

SLIDER CASEMENT AIR CONDITIONER

SLIDER CASEMENT AIR CONDITIONER OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS SLIDER CASEMENT AIR CONDITIONER ROTARY CONTROL P/N 309000854 (11/03) ROOM AIR CONDITIONER WARRANTY Your product is protected by this warranty Your appliance

More information

MIMAKI ENGINEERING CO., LTD.

MIMAKI ENGINEERING CO., LTD. Daily Care Manual Request for daily care Inkjet printer is the precision machine that has highly delicate mechanism. Especially, little dust and paper powder may have effect on a head nozzle firing ink,

More information

Owner s Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

Owner s Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS SPLIT-TYPE ROOM AIR CONDITIONER Owner s Manual Aurora Series All Model Numbers IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save

More information

OWNER S MANUAL HƯỚNG DẪN SỬ DỤNG

OWNER S MANUAL HƯỚNG DẪN SỬ DỤNG OWNER S MANUAL HƯỚNG DẪN SỬ DỤNG ENGLISH TI NG VIÊT AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit RAS-H10BKCVS-V Outdoor unit RAS-H10BACVS-V MÁY ĐI U HÒA KHÔNG KHÍ (LOẠI 2 KHỐI RỜI) S

More information

16 OUTDOOR MISTING FAN

16 OUTDOOR MISTING FAN 16 OUTDOOR MISTING FAN Model: SF-1670M READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USE IMPORTANT SAFETY INSTRUCTIONS When using electrical appliances, basic precautions should always be followed to

More information

Owner s Manual. Indoor Unit MMK-AP0074MH-E MMK-AP0094MH-E MMK-AP0124MH-E AIR CONDITIONER (MULTI TYPE) Model name: High-Wall Type.

Owner s Manual. Indoor Unit MMK-AP0074MH-E MMK-AP0094MH-E MMK-AP0124MH-E AIR CONDITIONER (MULTI TYPE) Model name: High-Wall Type. AIR CONDITIONER (MULTI TYPE) Indoor Unit Model name: High-Wall Type MMK-AP0074MH-E MMK-AP0094MH-E MMK-AP0124MH-E English Thank you very much for purchasing TOSHIBA Air Conditioner. Please read this owner

More information

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner Operating Instructions Air Conditioner Model No. Indoor Unit CS-E7NKR CS-E9NKR CS-ENKR CS-E5NKR CS-E8NKR CS-ENKR CS-E4NKR CS-E8NKR Outdoor Unit CU-E7NKR CU-E9NKR CU-ENKR CU-E5NKR CU-E8NKR CU-ENKR CU-E4NKR

More information

AIR CONDITIONER OWNER S MANUAL ENGLISH FRANÇAIS ESPAÑOL

AIR CONDITIONER OWNER S MANUAL ENGLISH FRANÇAIS ESPAÑOL OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : FLOOR STANDING ENGLISH FRANÇAIS ITALIANO ESPAÑOL ESPAÑOL DEUTSCH P/NO

More information

Outdoor Beverage Center

Outdoor Beverage Center ON/OFF SET TEMPERATURE Outdoor Beverage Center Use and Care Guide Be sure unit is standing upright 24 hours prior to plug-in. Model: BBQ10715 IMPORTANT SAFEGUARDS Read all instructions before using this

More information

OPERATING MANUAL R410A FUJITSU GENERAL LIMITED REFRIGERANT. AIR CONDITIONER Compact Cassette Type HEAT & COOL MODEL (REVERSE CYCLE) P/N

OPERATING MANUAL R410A FUJITSU GENERAL LIMITED REFRIGERANT. AIR CONDITIONER Compact Cassette Type HEAT & COOL MODEL (REVERSE CYCLE) P/N OPERATING MANUAL AIR CONDITIONER Compact Cassette Type HEAT & COOL MODEL (REVERSE CYCLE) R410A REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A. THIS PRODUCT MUST ONLY BE INSTALLED

More information

COMPRESSOR TYPE DEHUMIDIFIER DÉSHUMIDIFICATEUR D AIR LUFTENTFEUCHTER LUCHTONTVOCHTIGER TD-C100

COMPRESSOR TYPE DEHUMIDIFIER DÉSHUMIDIFICATEUR D AIR LUFTENTFEUCHTER LUCHTONTVOCHTIGER TD-C100 COMPRESSOR TYPE DEHUMIDIFIER DÉSHUMIDIFICATEUR D AIR LUFTENTFEUCHTER LUCHTONTVOCHTIGER TD-C100 OPERATING MANUAL ENGLISH P. 1 MANUAL D UTILISATION FRANÇAIS P. 5 BEDIENUNGSANLEITUNG DEUTSCH P. 9 GEBRUIKSAANWIJZING

More information

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner Operating Instructions Air Conditioner Model No. Indoor Unit CS-S9NKUW-1 CS-S1NKUW-1 CS-S18NKU-1 CS-SNKU-1 Single Split Outdoor Unit CU-S9NKU-1 CU-S1NKU-1 CU-S18NKU-1 CU-SNKU-1 Multi Split Outdoor Unit

More information

COMPRESSOR TYPE DEHUMIDIFIER DÉSHUMIDIFICATEUR D AIR LUFTENTFEUCHTER LUCHTONTVOCHTIGER TD-C120 TD-C160

COMPRESSOR TYPE DEHUMIDIFIER DÉSHUMIDIFICATEUR D AIR LUFTENTFEUCHTER LUCHTONTVOCHTIGER TD-C120 TD-C160 COMPRESSOR TYPE DEHUMIDIFIER DÉSHUMIDIFICATEUR D AIR LUFTENTFEUCHTER LUCHTONTVOCHTIGER TD-C120 TD-C160 OPERATING MANUAL ENGLISH P. 1 MANUAL D UTILISATION FRANÇAIS P. 5 BEDIENUNGSANLEITUNG DEUTSCH P. 9

More information

Dehumidifier. Instruction Manual. Model DH-320/A

Dehumidifier. Instruction Manual. Model DH-320/A Dehumidifier Instruction Manual Model DH-320/A CONTENTS Safety Warnings 2 Operation consideration 5 Construction & controls 6 Function selection 8 Preparation for use 10 Operation 12 Maintenance 14 Continuous

More information

Room Air Conditioner OWNER'S MANUAL

Room Air Conditioner OWNER'S MANUAL Room Air Conditioner OWNER'S MANUAL IMPORTANT Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner. Please retain this owner's manual for future

More information

English AIR CONDITIONER OPERATING MANUAL. Compact Cassette Type Keep this manual for future reference P/N

English AIR CONDITIONER OPERATING MANUAL. Compact Cassette Type Keep this manual for future reference P/N AIR CONDITIONER English OPERATING MANUAL Compact Cassette Type Keep this manual for future reference P/N9374379477-03 OPERATING MANUAL AIR CONDITIONER/INDOOR UNIT/Compact Cassette Type P/N 9374379477-02

More information

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump. English Table of contents Table of contents About this document About the system. Components in a typical system layout... 3 Operation 3 3. Overview: Operation... 3 3. The user interface at a glance...

More information

SPLIT-TYPE AIR CONDITIONERS

SPLIT-TYPE AIR CONDITIONERS SPLIT-TYPE AIR CONDITIONERS INDOOR UNIT MSZ-GL25VGD MSZ-GL35VGD MSZ-GL42VGD MSZ-GL50VGD MSZ-GL60VGD MSZ-GL71VGD MSZ-GL80VGD OPERATING INSTRUCTIONS For user To use this unit correctly and safely, be sure

More information

SINGLE MOTOR UPRIGHT VACUUM CLEANER MODEL C

SINGLE MOTOR UPRIGHT VACUUM CLEANER MODEL C SINGLE MOTOR UPRIGHT VACUUM CLEANER MODEL C375-3 OPERATION SERVICE PARTS CARE CONTENT MPV3 VACUUM CLEANER Instruction Manual Important safety instructions....2 Technical specification..2 How to assemble..

More information

Ultima Pet Plus Instruction Manual

Ultima Pet Plus Instruction Manual Ultima Pet Plus Instruction Manual U6011 IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING (THIS APPLIANCE) When using an electrical appliance basic precautions

More information

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S RS-600 (CHS60SS)-GB-05.indd 1 6/8/2010 9:30:59 AM TABLE OF CONTENTS 1. Introduction 2 2. Safety precaution 2 3. Intended use 3 4. Parts supplied 3

More information

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT SPLIT TYPE INDOOR UNIT/OUTDOOR UNIT MODEL RAS-3EX9G / RAC-3EX9G RAS-8EX9G / RAC-8EX9G OUTDOOR UNIT INDOOR UNIT RAC-3EX9G RAS-3EX9G RAS-8EX9G RAC-8EX9G Instruction Manual Page ~40 To obtain the best performance

More information

ULTRASONIC HUMIDIFIER MODEL# BU6000 INSTRUCTION MANUAL

ULTRASONIC HUMIDIFIER MODEL# BU6000 INSTRUCTION MANUAL ULTRASONIC HUMIDIFIER MODEL# BU6000 INSTRUCTION MANUAL BU6000 Fig 1 A. Mist nozzle B. Water Tank C. Water View Window D. Water Tank Cap E. Humidifier Base F. Power Cord G. Airflow outlet H. Control Knob

More information

WALL MOUNTED AIR CONDITIONER OWNER S MANUAL. This manual applies to models: QHF025 QHF036 QHF050 QHF060 QHF065 QHF080

WALL MOUNTED AIR CONDITIONER OWNER S MANUAL. This manual applies to models: QHF025 QHF036 QHF050 QHF060 QHF065 QHF080 WALL MOUNTED AIR CONDITIONER OWNER S MANUAL This manual applies to models: QHF025 QHF036 QHF050 QHF060 QHF065 QHF080 READ BEFORE OPERATION When using this air conditioner in the European countries, the

More information

Owner's Manual TABLE OF CONTENTS

Owner's Manual TABLE OF CONTENTS 40MB*D Ducted Style Ductless System Sizes 09 to 48 Owner's Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY... 2 GENERAL... 2 PARTS LIST... 3 DISPLAY PANELS... 4 FUNCTION BUTTONS... 5 REMOTE CONTROL...

More information

WINDOW YORK TECHNICAL GUIDE. Single package Cooling only and Heat pump. Models YO-YM R407C YO V6 G YO V7 G

WINDOW YORK TECHNICAL GUIDE. Single package Cooling only and Heat pump. Models YO-YM R407C YO V6 G YO V7 G WINDOW TECHNICAL GUIDE Single package Cooling only and Heat pump Models YO-YM 09-24 R407C YM 09 V6 G YM 09 V7 G YO 12-19-24 V6 G YO 12-19-24 V7 G YORK List of Contents Page 1 - Safety...2 2 - Unit packaging...2

More information

DEHUMIDIFIER MODELS: SD-31E / SD-41E / SD-61E / SD-71E INSTRUCTION MANUAL

DEHUMIDIFIER MODELS: SD-31E / SD-41E / SD-61E / SD-71E INSTRUCTION MANUAL DEHUMIDIFIER MODELS: SD-31E / SD-41E / SD-61E / SD-71E INSTRUCTION MANUAL Please read these instructions thoroughly and keep it in a safe place for future reference. CONTENTS SAFETY PRECAUTUIONS... 2 ELECTRICAL

More information

Cabinet Refrigerators/Freezers Instruction manual

Cabinet Refrigerators/Freezers Instruction manual Cabinet Refrigerators/Freezers Instruction manual Model DL893-A/DL894-A/DL895-A/DL896-A/DL897-A/DL898-A/DL899-A /CK480-A Safety Tips Position on a flat, stable surface. A service agent/qualified technician

More information

THRU-THE-WALL AIR CONDITIONER

THRU-THE-WALL AIR CONDITIONER OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS THRU-THE-WALL AIR CONDITIONER ELECTRONIC CONTROL ELECTRONIC CONTROL P/N 309000856 (11/03) ROOM AIR CONDITIONER WARRANTY Your product is protected by this

More information

Vacuum Cleaner User's manual

Vacuum Cleaner User's manual Vacuum Cleaner User's manual EN Before first use, please read all instructions contained in this user's manual carefully, even if you are already familiar with using similar products. Only use this product

More information

INFRARED ZONE HEATING SYSTEM

INFRARED ZONE HEATING SYSTEM INFRARED ZONE HEATING SYSTEM OWNER S MANUAL Model No. ATI-HF-X www.advancedtechinfrared.com PLEASE SAVE THESE INSTRUCTIONS WARNING: READ THIS OWNER S MANUAL CAREFULLY BEFORE USE. Thank you for choosing

More information