Institute of Sustainable Energy Technology, The University of Nottingham, NG7 2RD * Corresponding author

Size: px
Start display at page:

Download "Institute of Sustainable Energy Technology, The University of Nottingham, NG7 2RD * Corresponding author"

Transcription

1 12 th International Conference on Sustainable Energy Technologies (SET-2013) 26-29th August, 2013 Hong Kong A Novel Solid Oxide Fuel Cell Tri-Generation System for Low Carbon Buildings Theo Elmer 1*, Mark Worall 2, Saffa B Riffat 3 1, 2, 3 Institute of Sustainable Energy Technology, The University of Nottingham, NG7 2RD * Corresponding author laxte1@nottingham.ac.uk ABSTRACT As a result of growing concerns of climate change and ever increasing cost and scarcity of fuel resources, fuel cells with their high electrical efficiency, low emissions and useful heat output have been identified as a key technological option for improving both building energy efficiency and reducing emissions. A 1.5kW e low temperature solid oxide fuel cell (SOFC) liquid desiccant trigeneration system has been proposed as an environmentally friendly way of providing heating, cooling and electricity to low carbon buildings. The described system will be constructed and trialled at The University of Nottingham as part of a European Union (EU) funded project named Durable Solid Oxide Fuel Cell Tri-generation System for Low Carbon Buildings (TriSOFC). The aim of this paper is to provide an introduction to the EU TriSOFC project. The paper is split into three parts. The first part, section two, provides details of the TriSOFC system along with project aims and objectives. The second part, section three, presents a review of the state-of-the art surrounding fuel cell and desiccant based tri-generation systems. Conclusions of the review are discussed in terms of their impact on the TriSOFC system, most significantly (1) a considerable gap in the literature currently exists surrounding tri-generation energy systems based on SOFC combined with liquid desiccant air conditioning technology and fuel cell based tri-generation systems in residential applications (2) the thermal output of a fuel cell combined heat and power (CHP) system is in good thermal agreement with desiccant regeneration temperatures, making them appropriate companion technologies for integration in a tri-generation system concept, and (3) maximising thermal energy utilisation in CHP and tri-generation systems is challenging, and can have a large impact on system efficiency. The third part of the paper, section four, presents the parametric modelling results for a liquid desiccant air conditioner. Parametric studies have investigated the influence that, cooling and heating water temperature, fluid flow rates, inlet air conditions and desiccant solutions (LiCl, CaCl 2 and CHKO 2 ), have on performance. There are four conclusions from the modelling work. First, the moisture removal rate of the supply air is strongly controlled - assuming constant mass flow rate, by desiccant temperature and cooling water temperature. Second, the air inlet conditions have a large influence on performance in terms of cooling output. The unit will generally perform better in a hot and more humid climate such as southern China, as opposed to drier cooler climates such as the UK. Third, as the regeneration heat source temperature increases, the mass of water vapour vaporised from the weak desiccant solution increases. Fourth, in this model the CHKO 2 desiccant solution shows the highest performance for the given conditions, and with its low environmental impact, is a suitable solution for the desiccant unit in the TriSOFC system. A separate paper presented at this conference (Paper ID: 334) reports the development of computer simulations carried out to evaluate the novel desiccant membrane contactor design that will be used in TriSOFC and size the desiccant system. KEYWORDS: Fuel cell, tri-generation, liquid desiccant air-conditioning, low carbon buildings 1. INTRODUCTION The aim of this paper is to provide an introduction to the EU project Durable Solid Oxide Fuel Cell Tri-generation System for Low Carbon Buildings (TriSOFC). The paper is split into three sections. The paper is split into three parts. The first part, section two, provides details of the TriSOFC system along with the aims and objectives. The second part, section three, presents a review of the state-of-the art surrounding fuel cell and desiccant based tri-generation systems. The third part, section four, presents the parametric modelling results for the liquid desiccant air conditioner that will be used within the tri-generation system. The central aim of the EU project is to design, develop and test a proof-of-concept tri-generation system based on solid oxide fuel cell (SOFC) and liquid desiccant air conditioning technology, to provide heating, cooling and electricity to a low carbon building application. Currently there is growing demand for energy in buildings and an increasing concern regarding the detrimental environmental impact emissions of pollutants such as CO 2 have. The TriSOFC system is a strong candidate for providing an energy efficient, low carbon alternative to traditional building energy supply. The proposed TriSOFC system shown in Figure 1 is truly multi-functional, designed to provide the energy needs of a building throughout all seasons. The SOFC is the core of the system, generating electricity through electrochemical reactions using hydrogen from the natural gas stream. The only by-products are water vapour, heat and a modest amount of CO 2 using a fuel cell is a more efficient process than simply combusting the fuel [1]. The desiccant air conditioning cycle is predominately driven by heat for regeneration; therefore it is an attractive option for integration with a SOFC. The desiccant air conditioning unit will be used to produce dehumidified cool air in summer, and dehumidified warm air in winter. Furthermore, the utilisation of waste heat from the fuel cell can provide a means of effective thermal management to the stack, ensuring both increased performance and longevity of the entire system. The use of desiccant as a means of thermal storage has also been proposed and will feature in the final system. The fuel cell technology will be based on solid oxide. The liquid desiccant dehumidifier will be based on a cellulose fibre membrane to hold the desiccant solution and prevent carry-over. The desiccant dehumidifier will be incorporated alongside an indirect evaporative dew point cooler to provide further sensible cooling to supply air. 1

2 Figure 1 TriSOFC system concept [2] Within the EU project, the authors are responsible for the desiccant unit development. Therefore modelling work to date has focussed on this. The initial modelling work uses a relatively simple method proposed by Gandhidasan [3] based on dimensionless vapour pressure and temperature difference ratios for the preliminary design of a liquid desiccant dehumidifier and regenerator system. The modelling work has been validated by well-regarded experimental data presented in the literature by Fumo and Goswami [4]. Parametric analyses have been conducted and investigate the influence cooling water temperature, fluid flow rates, inlet air conditions and desiccant solutions LiCl, CaCl 2 and CHKO 2 have on the performance of the dehumidifier; namely moisture removal rates and cooling output. The regenerator has also been studied to identify the influence regeneration temperature has on performance. The results have been commented upon and their influence on system design and optimisation discussed. As previously stated, the proposed desiccant air conditioning system used in TriSOFC will be based on a novel cellulose fibre membrane contactor design. A separate paper presented at this conference (Paper ID: SET ) reports the development of computer simulations carried out to evaluate the novel membrane contactor (heat and mass exchange effectiveness) and size the system. 2. THE TriSOFC PROJECT TriSOFC is a consortium based project, involving eight collaborators from across Europe. The overall aim is to define, develop and deliver a novel low-cost durable low temperature SOFC tri-generation prototype. The system will be based on the breakthroughs in low temperature SOFC and liquid desiccant air conditioning technology already made by the consortium members. The fuel cell innovation involves recent advances in low temperature SOFC technology using ceria-carbonate two or multi-phase nanocomposite materials. These materials have illustrated that high electrochemical performance of up to 1.2 W/cm 2 can be achieved at reduced temperatures of 500 C, with excellent tolerance to sulphur poisoning and carbon deposition. These developments are a clear advantage for the domestic sector where high temperature operation ( C) results in technical complexity and consequent costs that inhibit commercialisation. Furthermore these developments mean SOFC stacks can be manufactured for prices below 400 /kwe compared to 1000 /kwe for conventional SOFC systems [2]. The use of these new materials also makes the prospect of using single cell construction technology a possibility, which would mean a simpler fabrication procedure and further reductions to cost. The innovations surrounding the liquid desiccant air conditioning unit is the development of a novel cellulose fibre membrane contactor design. The membrane can effectively prevent desiccant carry-over into the supply air stream, a particular issue in previous contactor designs [5, 6]. Furthermore, the membrane design provides greater contacting surface area between the air and desiccant solution, improving the efficiency of the air conditioning process. There are several technical aims for TriSOFC; these have been summarised in Table 1. Table 1 summary of technical aims of the tri-generation system [2] Technical Parameter Goal Fuel cell electrical power 1.5 kw System efficiency (based on natural gas) > 90% Electrical efficiency > 45% It has been predicted that the described TriSOFC system running on hydrogen from the natural gas network will result in a 70% CO 2 emission reduction compared to a traditional energy production system comprising of separate condensate power plant, boiler and compressor driven cooling unit. The TriSOFC system will be installed and tested in the Creative Energy Homes, at The University of Nottingham. This work will provide a real world application study for fuel cell tri-generation system operating in a stationary low carbon building environment. Such a study is a great opportunity as the majority of previous works related to the topic have either been theoretical or laboratory based. However, as highlighted in the review of the literature presented in Section Two, effective system integration in a real world application will be a challenging aspect of the project. A project website documenting progress of the EU project has been set up at 2

3 3 3. TRI-GENERATION SYSTEMS Tri-generation can be deemed a subset of a term known as Combined Heat and Power (CHP). CHP is defined as the generation of heat and power from a single fuel source, with a view to use both products. Tri-generation systems take this concept one step further by producing a cooling output. By consuming the often wasted heat produced in the electrical generation process system efficiency can be elevated from as low as 20% (depending on the electrical generator) to nearly 90% in tri-generation applications. This results in reduced emissions and running costs. Because a fuel cell produces heat whilst generating electricity they are particularly well suited to tri-generation applications. Literature searches have shown that a fuel cell tri-generation system utilising liquid desiccant air conditioning technology will be the first of its kind: no research activity is reported on fuel cell and liquid desiccant air conditioning. However, there are a small number of research publications and patents that focus on SOFC tri-generation systems [7-11]. These works either focus on the use of the fuel cells thermal output in a Rankin bottoming cycle or the use of vapour absorption cooling. Although little/no work has been found directly relating to the proposed concept, the rationale and initial thinking behind the success of the proposed system is that liquid desiccant regeneration temperatures are lower than that of solid desiccant media [3], therefore a well suited technological partnership for a fuel cell CHP system, with a low temperature output of C [12]. Because no research publications have been found detailing fuel cell-liquid desiccant systems, the review of the current literature has been split into two key areas: (1) Fuel cell tri-generation systems (2) Liquid desiccant based tri-generation systems It is hoped this approach will highlight important findings, such as: system design, performance, operational issues and evaluation techniques. These lessons can then be applied to the TriSOFC system. 3.1 FUEL CELL TRI-GENERATION SYSTEMS This section will examine tri-generation systems employing fuel cell technology. Fuel cells are well suited to tri-generation applications because they produce heat when generating electricity, have low emissions, high efficiency and excellent load following characteristics whilst maintaining high electrical efficiency [7, 13-15]. Furthermore, continued technological improvements to fuel cells (durability, reliability) have facilitated an increased interest in fuel cell tri-generation systems [15]. Yu, Han et al. [15] have numerically investigated a tri-generation system incorporating a SOFC and a double-effect water/lithium bromide absorption chiller. High system efficiencies of 84% or more were reported by the authors, illustrating the benefits of trigeneration systems in applications where heating, cooling and power is required. Margalef and Samuelsen [16] numerically examined a 300kW molten carbonate fuel cell tri-generation system using absorption cooling. The system achieved an overall efficiency of 72%. However, the pairing of two off the shelf technologies for tri-generation system construction can be problematic. As Margalef [16] states, the molten carbonate fuel cell and absorption chiller chosen for the tri-generation system were close, but not an ideal match. The fuel cell exhaust gas temperature was higher than the inlet temperature specified for the chiller and the exhaust gas flow rate was not sufficient to achieve the required heat recovery within the chiller heat exchanger. Therefore two strategies to overcome this were presented (1) blending the fuel cell exhaust gases with ambient air, and (2) mixing the fuel cell exhaust gases with a fraction of the chiller exhaust gas. Both options worked, however the second option yielded better performance and was thus used. Al-Sulaiman, Dincer et al. [7] presents an energy analysis of a tri-generation plant incorporating a 520kW SOFC, organic Rankin cycle, heat exchanger and single effect absorption chiller. The investigation shows that incorporating the cooling cycle system efficiency is improved by 22% compared to just having the SOFC and organic Rankin cycle running together. A maximum trigeneration efficiency of 74% has been achieved. The above investigations have however been for larger commercial applications. Limited work has been carried out on residential scale tri-generation systems due to system size, cost and complexity. The work that has been completed has mainly focussed on simulation studies. The most appropriate are summarised below. Bhatti, O'Brien et al. [8] present a patent publication for a SOFC assisted air conditioning system based on solid desiccant and evaporative air conditioning technology. The aim of the system is to provide both comfort cooling and heating. The authors state that the most common technology to provide cooling/heating is a reversible heat pump; however these use electric power to drive the compressor. Desiccant enhanced systems are a low energy alternative to this. The thermal energy from the SOFC is used to regenerate a solid desiccant wheel, which addresses the buildings latent load, whilst an evaporative cooler is used to address the sensible load. No performance data is available, however it is expected the system will provide high co-generation efficiency and a measurable energy reduction in comparison to a separate vapour compression system, boiler and grid electricity system. Braun, Klein et al. [17] have developed a system model to evaluate the performance of different residential scale SOFC CHP systems. The authors explain that currently a considerable gap exists in the area of techniques to maximise the benefits of fuel cell systems, both in terms of electrical generation and thermal utilisation. The authors state that the majority of previous work has

4 4 been focussed on large applications, not residential. Braun, Klein et al. looked at a SOFC CHP system with an electrical power output of around 1.5kW, a thermal output of 60 C, and a heat to power (H:P) ratio of 0.7 to 1.0. Five system configurations were studied: (1) hydrogen fuelled (2) methane fuelled with external reforming (ER), and internal reforming (IR) (3) methane fuelled with cathode gas recycle (CGR) (4) methane fuelled with anode gas recycle (AGR), and (5) integration of CGR, AGR and IR. The results are based on thermodynamic models which simulate the efficiency performance of the fuel cell co-generator. It was found that optimisation of each system is dependent upon the cell power density and the required H:P of the application. A summary of the results are as follows: (1) the hydrogen fuelled SOFC did not offer any efficiency advantages over methane for both IR and ER, in some cases the magnitude of efficiency advantage of methane can be as high as 6% (2) using IR in the SOFC reduces the system air flow by 50%, thus producing a higher electrical efficiency, but the CHP efficiency remains low (3) CGR enhances performance (system efficiency), by eliminating the system air input and pre-heater requirement (4) AGR and CGR with IR produces the highest CHP efficiency and a H:P ratio near one, whilst minimising the air-pre-heater and air blower requirement. These results show potential optimisation considerations for the TriSOFC system and that the proposed system should not suffer any efficiency losses due to its operation on natural gas. Pilatowsky, Romero et al. [18] have carried out simulation based work on a 1kWe Proton Exchange Membrane Fuel Cell (PEMFC) coupled to an absorption cooling system. The simulations were completed to determine the optimum operating conditions of the air conditioning system during the co-generation process; primarily the cooling capacity at maximum power output from the PEMFC. The absorption cycle was operated with a monomethylaminre-water solution, with a low vapour generation temperatures of around 80 C, ideal for PEMFC CHP applications. Results show that the co-generation process increases total efficiency of the system, illustrating the feasibility of using fuel cells in small scale combined cooling applications. Results from the simulation include (1) the Coefficient of Performance (CoP) of the absorption cooler increases as the generation temperature (from the fuel cell) increases, reaching a maximum value and then dropping off (2) the cooling power increase with an increase of the electrical power from the PEMFC and evaporation temperature of the absorption cooler, but decreases with an increase of generation temperature, and (3) the co-generation efficiency is almost independent of the electrical power, but strongly dependant on evaporation and generation temperatures of the absorption cooler. With recent advances in fuel cell CHP systems for residential applications, the feasibility of fuel cell tri-generation systems in domestic homes is strong. Fuel cell tri-generation systems can create substantial energy savings leading to reduced atmospheric pollution and operational costs. However an issue such as accurate pairing of technologies still needs careful consideration. Currently a large gap in the literature exists regarding SOFC tri-generation systems for residential applications. Published literature documenting SOFC tri-generation systems has focussed on either simulation or larger commercial based studies, utilising vapour absorption cooling. Little or no work has been found on experimental based domestic scale studies. There is a clear need for experimental work in both; fuel cell tri-generation systems operating in residential applications and fuel cell trigeneration systems incorporating liquid desiccant air conditioning technology. This need is due to the technologies suitability for integration and the patent advantages they can bring to total system efficiency. It is hoped work from the TriSOFC project will assist in contributing towards filling this significant gap. Next, liquid desiccant tri-generation systems will be examined. 3.2 LIQUID DESICCANT BASED TRI-GENERATION SYSTEMS This section will provide a brief review of tri-generation systems employing liquid desiccant air conditioning technology. An interesting study of a system employing an internal combustion engine and vapour absorption cooling is provided by Liu, Geng et al. [19]. The study illustrates the benefits a desiccant based air conditioning system can bring to a tri-generation system setup. Liu, Geng et al. [19] investigated a hybrid tri-generation HVAC system in a multi-storey demonstration building, employing an internal combustion engine, liquid desiccant and vapour absorption cooling technology. The investigation highlighted issues with conventional tri-generation systems that use a straight absorption cooling cycle, these include: (1) low grade waste heat from the prime mover is used directly to drive the cycle, leading to low energy performance and thus a CoP (thermal) of 0.7 or less (2) how to match electrical and thermal loads of the building and lengthen the operating hours of the tri-generation system (thus improving benefits from the system), and (3) dehumidification in an absorption cooling systems is achieved by cooling the air below its dew point, then re-heating the air before supplying it to the room, this lowers the CoP because supply air temperature is required at 7-12 C, it is also easier to cause health problems; condensed water makes the coil surface a hot bed for bacteria. However, the authors found a way of avoiding the above problems when using a hybrid system consisting of liquid desiccant, absorption and thermal/desiccant storage. The solutions are as follows: (1) the regeneration of liquid desiccant does not need high grade heat, only C, thus CoP improvements of ~1.2 to 1.3 can be achieved (2) a thermal/desiccant storage tank can be used to match differences between thermal supply and demand, and (3) the liquid desiccant system will remove the latent load, therefore avoiding the need to cool then re-heat. A simulation was carried out to analyse the performance of the building with the different system configurations i.e. with and without liquid desiccant. Results show that CO 2 emissions are reduced by about 40%, and energy storage plays an important role in the hybrid liquid desiccant system. Qiu, Liu et al. [20] have carried out an experimental investigation of a liquid desiccant air conditioning system driven by the flue gases of a biomass boiler. The air conditioning system consists of two parts; first, the dehumidifier and secondly the dew point cooler. The desiccant dehumidifier used was of a direct contact counter flow falling film design, using a potassium formate solution. Internal desiccant cooling was provided from an evaporative device. The system was operated in autumn in Nottingham,

5 UK and was found to be able decrease air temperature by 4 C and relative humidity by 13%. The total cooling capacity of the system was found to be 2381W, the evaporative cooling device alone had a cooling capacity of 1049W, and illustrating the dehumidifier plays a significant role in air conditioning by reducing the supply airs internal energy through dehumidification. Electrical consumption for fans and pumps totalled ~ 200W; therefore the desiccant cooling systems CoP was in the range of 11-12, an encouraging value. It was found that the heat from the flu gas was insufficient to heat the desiccant solution to the required 40 C, only 30 C was reached, as a result future work will look at improving the flue gas heat exchanger. This work has proved that desiccant systems are effective cooling devices in waste heat scenarios, however issues such as waste heat recovery effectiveness needs to be addressed in order to maximise operating performance. Finally, the experimental results confirm that cooling is a result of lowering both humidity and air temperature, and high CoP values are attainable in a working environment critical in tri-generation system applications. Liquid desiccant systems employed in tri-generation applications can offer environmental, economic and operational advantages over other heat driven cooling cycles. Furthermore, vapour absorption cooling is rarely used in tri-generation applications of less than 10kW [21], therefore liquid desiccant is a particularly well suited air conditioning option for domestic scale tri-generation applications. 3.3 CO-GENERATION THERMAL OPTIMISATION FOR HOUSING INTEGRATION This section will deal with how the full potential of co-generation systems may be realised. When a CHP system is grid interactive i.e. electrical energy can be imported or exported, maximising the use of generated electrical energy is relatively simple. Excess generation may be exported, and in periods of insufficient generation, electricity may be imported. However as Elmer [22] states it is of greater value to the user to consume all/as much self-generated electricity onsite because the export tariff is lower than the import tariff. Maximising the use of thermal energy generated by a CHP systems is however more complex. The degree of thermal utilisation is a decisive factor in CHP system efficiency values, and will impact on cost and emission savings. The heat led nature of combustion based CHP systems (internal combustion engine) means they should only be operational when demand for thermal energy is present [23]. Fuel cells, particularly SOFCs have very different operational characteristics, most significantly a low H:P ratio and the requirement of constant operation to avoid thermal cycling. Thermal cycling can lead to accelerated voltage degradation within the cells. However, the majority of the UK housing stock is characterised by peak morning and evening heating demands, shown in Figure 2a. How fuel cell CHP systems with their preference for constant operation are effectively integrated into buildings is a challenging task. Figure 2 (a) conventional UK heating profile left, and (b) slow heating demand right [24] A number of studies have been carried out trying to address this issue. Kato, Iida et al. (2003) investigated the use of thermal energy storage (TES) in a residential PEMFC application. It was found that a high level of temporal precision was required in order to match the domestic hot water demand and to correctly size the system components. For a 2kWe installation, a litre TES was required to effectively make use of the PEMFCs thermal output. Hawkes, Aguiar et al. (2007) present a SOFC CHP model for use in a techno-economic analysis to determine options in the provision of residential heat demand in the UK. Four different UK heating demand profiles were considered to see which profile best suited that of a SOFC CHP system using a cost minimisation model. The model also included the use of TES. The base case model, shown in Figure 2a was based on a typical UK heat load profile. Results showed that a slow space heating demand, seen in Figure 2b, running constantly in winter with under floor heating was most suitable for the SOFC due to maximum thermal energy utilisation. This profile achieved highest cost and CO 2 savings compared to the reference study of grid electricity and gas fired boiler. The slower heating demand is also a better match for SOFC technology due to the avoidance of thermal cycling. TES provided added benefit to the system. 3.5 LITERATURE SEARCH CONCLUSIONS AND IMPACT ON TriSOFC The review of literature presented in this paper has been used to provide a background study on the state of the art surrounding: fuel cell tri-generation systems, desiccant tri-generation systems and thermal optimisation methods for residential co-generation applications. The literature has been selected based on its appropriateness and suitability in addressing the central research aims of the project. Three main conclusions of the review are summarised below: (1) Currently there is large gap in the literature regarding fuel cell based tri-generation systems incorporating liquid desiccant air conditioning technology. This is believed to be a result of three key factors: cost, system size/complexity and relative infancy of technological development, particularly for domestic applications. It is intended that the TriSOFC project will 5

6 assist in contributing to filling this gap and addressing the proposed barriers of development, thus justifying the future use of the proposed system concept. (2) An opportunity that the literature review has highlighted is the rationale for TriSOFC. A fuel cell CHP system output temperature (~60 C) is in good thermal agreement with the required desiccant regeneration temperature (45-50 C), making integration of the two technologies a feasible and attractive option for low carbon buildings. However caution will be taken due to the issues other researches have encountered when coupling off the shelf components. (3) Challenges the literature review has highlighted is that system integration, optimisation and energy utilisation is not a large issue in theoretical or laboratory based projects, thus high system efficiencies have been reported. However in a real world working environment, effective energy utilisation can pose a serious challenge to the system, specifically how to maximise the utilisation of the energy outputs of the system in order to improve system efficiency. If this cannot be effectively addressed it will have a large impact on the final feasibility of the system. 4. COMPONENT MODELLING Modelling work is an essential task for the design, building, testing and optimisation of the liquid desiccant air conditioning unit used in the TriSOFC system. Modelling work will be used to: identify the important operating parameters of the desiccant unit to facilitate its optimisation, for predicting the performance of the unit under set conditions and to assist in sizing a suitable unit for TriSOFC. The 1-D model described below has been used to identify important operating parameters and establish initial performance estimates. The performance of a desiccant dehumidifier is strongly related to the quantity of water condensed from the humid air to the desiccant solution in the dehumidifier, this quantity should be balanced with the amount of water vaporised in the regenerator [3]. In the literature there are numerous validated models predicting this quantity, however it should be stated that the majority of these correlations are only valid to the specific desiccant unit and solutions for which the correlations were obtained. Therefore, a simplified model to estimate the preliminary performance of the novel cellulose fibre packed bed system based on fundamental equations would be valuable at this stage. The preliminary modelling task has called upon the work of Gandhidasan [3] and Gandhidasan [25]. Gandhidasan describes a relatively simple model for the preliminary design of a liquid desiccant dehumidifier and regenerator system, using dimensionless vapour pressure and temperature difference ratios Eq. (5) and (6). These ratios are used to derive an expression to determine the mass of water vapour condensed from the air to the solution in the liquid desiccant dehumidifier Eq. (3Error! Reference source not found., and for the mass of water vaporised from the desiccant solution to the scavenging air stream in the regenerator Eq. (4). Both of these equations are used in terms of known operating parameters. The model has been validated by well-regarded experimental data presented in the literature provided by Fumo and Goswami [4] with very good agreement. The dimensionless temperature difference ratio (β) is defined for the dehumidifier in Eq. (1) and for the regenerator in Eq. (2) (1) For the dehumidifier, the water condensation rate (m) as presented by Gandhidasan [3] is given in Eq. (3): (2) For the regenerator, the water evaporation rate (m) as presented by Gandhidasan [25] is given in Eq. (4): (3) The heat capacity rate of the desiccant solution (C s ) is defined in Eq. (5): (4) The heat capacity rate of the humid air (C a ) is defined in Eq. (6): (5) 6 (6)

7 Where; m = mass of water vapour condensed/vaporised (g/s) or per unit cross-sectional area (g/m 2.s) h fg = latent heat of vaporisation (kj/kg) G = mass flux or flow rate per unit cross-sectional area (kg/m 2.s) C = heat capacity rate (kw/ C) C p = Specific heat capacity (kj/kg.k) t = temperature ( C) Greek letters λ = latent heat of condensation (kj/kg) η = heat exchanger effectiveness (%) β = dimensionless temperature difference ratio Eq. (5) Subscripts a = air c = cooling medium (water) d = dehumidifier HE = Heat exchanger i = inlet o = outlet r = regenerator s = desiccant solution Data for the desiccant solutions needed to be acquired to use the aforementioned relationships. The specific heat capacities and enthalpy of dilution is required for the desiccant solutions at different concentrations and temperatures. Curve fitting and linear regression analysis has been used to do determine the required properties from the data presented by Conde [26] for LiCl and CaCl 2. Melinder [27] was used for the lesser known physical characteristics of the CHKO 2 (Potassium Formate) solution. Figure 3 shows the simplified schematic of the desiccant system used in the modelling process, with the labelled desiccant solution and airflows. Figure 3 model schematic 3.1 DESICCANT SYSTEM WORKING PRINCIPLE In the dehumidifier mass transfer (dehumidification) occurs due to differences in vapour pressures. The cool concentrated desiccant solution exhibits a vapour pressure which is lower than that of the water vapour present in the humid air, therefore the moisture moves from the air to the solution. In addition to this, in summer, it is expected that the temperature of the humid air that enters the desiccant dehumidifier is higher than the desiccant solution temperature, therefore sensible heat transfer will also occur. The greater the cooling of the desiccant solution prior to entering the dehumidifier, the greater the heat and mass transfer, and thus the greater cooling output. Following dehumidification, the weak desiccant solutions needs to be regenerated i.e. re-concentrated. This takes place in the regenerator. Prior to entering the regenerator the desiccant is heated, first in the desiccant to desiccant heat exchanger (also used to pre-cool the desiccant flowing to the dehumidifier), then using an external source e.g. the fuel cell. In the regenerator, the heated weak desiccant solution will have a vapour pressure higher than that of the scavenging air stream, thus the water vapour present in the solution will transfer (vaporise) to the air stream, thus re-concentrating the desiccant solution ready for dehumidification in the dehumidifier. The modelling work was carried out using Engineering Equation Solver (EES), a general equation solving program that can numerically solve thousands of coupled non-linear algebraic and differential equations. Air and water property routines are inbuilt functions in EES, making calculations involving psychrometric functions much easier. Once the model had been developed, and adjusted such that the output results were in good agreement with the experimental and theoretical results presented by Gandhidasan [3], Gandhidasan [25] and Fumo and Goswami [4], parametric analyses were carried out. Parametric analysis for the dehumidifier and regenerator has looked at the variation of mass condensed/evaporated in the dehumidifier/regenerator respectively with: 7

8 mass flux condensed (g/m2.s) Cooling water temperature Regeneration heating temperature Fluid flow rates (air and desiccant) Fluid flow rate ratios Heat exchanger effectiveness Desiccant solutions LiCl, CaCl 2 and CHKO 2 Furthermore a parametric analysis focussing on the variation of the inlet air conditions to the desiccant dehumidifier was investigated. This was to see the effect environmental conditions had on performance. In this analysis, the following were assessed in terms of cooling output: Air inlet temperature (t a,i ) Air inlet relative humidity (RH a,i ) Model boundary conditions (unless a varied parameter): Air inlet temperature = 35 C Air inlet RH = 70% Desiccant inlet concentration = 35% Desiccant inlet temperature = 30 C Air mass flux = 1 (kg/m 2.s) Desiccant mass flux = 2 (kg/m 2.s) Air to desiccant flow rate ratio = 2 Heat exchanger effectiveness = 60% Beta value = 0.5 taken from the literature Cooling water temperature = 29 C Regeneration heating temperature = 70 C All the solutions flow rates are given as mass flux values i.e. per m 2 of contactor, thus all results are presented in terms of per m 2 of contactor area, either; mass condensed/vaporised or cooling output. The parametric analyses have been carried out for the LiCl solution as this work has been validated with the well regarded work of Fumo and Goswami (2002). This study will allow the working principles and underlying relationships involved in a desiccant air conditioning cycle to be identified. Following this, a comparison of the cooling output potential of the three different desiccant solutions is made LiCl, CaCl 2 and CHKO 2. The modelling results are split into two sections: dehumidifier and regenerator. 3.2 DEHUMIDIFIER ANALYSIS (i) Influence of cooling water temperature on mass condensed - LiCl t c,i = 28.5 C t c,i = 29 C t c,i = 29.5 C Desiccant flow rate (kg/m2.s) Figure 4 the effect of cooling water temperatures on dehumidification Figure 4 shows how decreasing the cooling water temperature increases the mass flux condensed in the dehumidifier. This is due it creating a lower desiccant temperature and thus increased dehumidification potential the lower the temperature, the lower the vapour pressure exhibited by the desiccant. For internally cooled cycles, it also means greater removal of the latent heat of condensation. Gandhidasan [3] states that the performance of a desiccant dehumidifier is improved with pre-cooling, the lower the better, thus a lower cooling water temperature yields improved dehumidification performance. 8

9 Cooling output (W/m 2 absorber) Mass flux condensed (g/m2.s) RH a,out,d (%) (ii) Influence of solution flow rate ratio on mass condensed and outlet RH - LiCl RH a,out,d mass flux condensed Y d kg sol in / kg air in Figure 5 the effect of desiccant solution flow rate ratio on dehumidification 0.46 Figure 5 shows that as the solution to air flow rate ratio increases, the mass flux condensed increases, and thus the RH of outlet air decreases. This is because more desiccant solution is supplied per unit of air. However, as Lowenstein [6] states, the parasitic energy load of supplying the desiccant solution and air is one of the largest issues regarding liquid desiccant systems as this has a large influence on the CoP of the cycle. Therefore fluid supply flow rates need to be balanced against the parasitic energy load. Furthermore if desiccant and air supply flow rates are too high it can create issues of desiccant carry-over to the supply air stream. The cooling output of an air conditioning device is made up of both sensible and latent parts, and is usually a mixture of the two. In the desiccant dehumidifier, latent cooling is due to mass transfer, and sensible cooling is due to the temperature difference between the humid air and desiccant solution. The cooling output of the desiccant dehumidifier has thus been assessed using the mass flux of air supplied multiplied by the difference in enthalpy between the inlet and outlet air, seen in Eq. (7). This gives a cooling output per m 2 of absorber. Q cooling = G a,d ( h a,in h a,out ) (7) Where: G a,d = mass flux of supplied air to the dehumidifier (kg/m 2.s) h a,in = inlet air specific enthalpy (J/kg) h a,out = outlet air specific enthalpy (J/kg) (iii) Influence of inlet air temperature on cooling output - LiCl Air inlet temperature ( C) Figure 6 the effect of inlet air temperatures on cooling output 9

10 Cooling output (W/m2) Cooling output (W/m 2 absorber) Figure 6 shows that as the inlet air temperature increases the cooling output for the LiCl solution increase, this is because there is a greater temperature difference between the solution and inlet air, thus sensible heat transfer is increased, leading to an increased cooling output. (iv) The influence of inlet air relative humidity on cooling output - LiCl Inlet air relative humidity (%) Figure 7 the effect of inlet air RH on cooling output Figure 7 shows as the relative humidity of the inlet air increases the cooling output also increases. This is because as the relative humidity of the air increase so does its partial pressure, therefore representing a greater dehumidification potential for the desiccant solution interacting with the humid air. (v) A cooling output comparison for different desiccant solutions Desiccant flow rate (kg/m2.s) Cooling output (W/m2) - LiCl Cooling output (W/m2) - CaCl2 Cooling output (W/m2) - CHKO2 Figure 8 cooling output comparisons for different desiccant solutions Figure 8 shows that at the given boundary conditions, the Potassium Formate desiccant solution has the best performance, with LiCl performing slightly better than the CaCl 2 over the varied desiccant solution flow rates. This is because at the stated boundary conditions, potassium formate has a higher specific heat capacity. As seen in Eq.(1) the specific heat capacity of the desiccant solution has a large influence on mass condensed in the dehumidifier, which in turn has a large influence on cooling output. 10

11 Evaporation rate [g/m2.s] Evaporation rate [g/m2.s] 3.3 REGENERATOR ANALYSIS (i) The influence of regeneration temperature on mass vaporised - LiCl 60 t h,r,i = 72 C t h,r,i = 70 C t h,r,i = 68 C 10 0 Air flow G a = 1 kg/m2.s Conc in = 34% Y = 2 kg sol in / kg air in Desiccant flow rate [kg/m2.s] Figure 9 influence of regeneration temperature on regeneration performance From Figure 9 it is clear that as the desiccant flow rate and regeneration temperature increases, the mass vaporised in the regenerator increases. This is because as the regeneration temperature increases, the desiccant temperature increases, leading to a greater vaporisation potential. This shows how the maximum recoverable heat should be obtained from the fuel cell in order to improve the desiccant system performance. An interesting point from Liu [28] is that when not using waste heat i.e. fuel cell, for the regeneration of the liquid desiccant, the lowest usable concentration of desiccant solution is preferred, as this creates the highest CoP. However when waste or renewable energy is available, the maximum recoverable heat possible should be targeted as this will result in a higher concentration of desiccant, resulting in improved cooling capacity and system CoP. (ii) Influence of heat exchanger effectiveness on mass vaporised - LiCl 70 HXe = HXe = HXe = Conc in = 34% Desiccant solution flow rate [kg/m2.s] Figure 10 influence of heat exchanger effectiveness on regeneration performance Figure 10 shows that an increase in heat exchanger effectiveness improves mass vaporised; again this is due to the increase in desiccant temperature i.e. more heat is exchanged to the desiccant solution. Both in Figure 9 and Figure 10, mass vaporised increases with descant solution flow rate, however as stated with the dehumidifier, increasing this needs to be balanced against parasitic energy consumption. 11

12 4.4 MODELLING CONCLUSIONS The parametric analyses have been used to identify the parameters that have the greatest influence on the performance of the desiccant dehumidifier and regenerator. The work has also shown the optimum environmental conditions for which the system should be operated in. The moisture removal rate of the supply air is strongly controlled - assuming constant mass flow rate, by desiccant temperature and cooling water temperature. The air inlet conditions have a large influence on performance in terms of cooling output. The unit will generally perform better in a hot and more humid climate such as southern China, as opposed to drier cooler climates such as the UK. In this model, the potassium formate desiccant solution shows the highest performance for the given conditions, and with its lower environmental impact compared to LiCl and CaCl 2, is a suitable solution for the desiccant unit in the TriSOFC system. As the regeneration heat source temperature increases, the mass of water vapour vaporised from the weak desiccant solution increases, although as Liu [28] explains, depending on the source of regeneration heat, too high a desiccant concentration is not always beneficial to system performance. If waste heat is available the maximum concentration of desiccant solution should be obtained. A higher regeneration temperature can also mean a lower desiccant solution and air flow rate are required (beneficial to CoP) in order to yield a similar solution outlet concentration and for the mass balance between the dehumidifier and regenerator to be satisfied. Although emergent, this modelling has illustrated the fundamentals of liquid desiccant air conditioning systems, namely the interactions observed in the parametric analysis. The current model does however have its limitations and is not particularly robust; for example it does not include the heat and mass exchanger effectiveness of the cellulose fibre membrane, geometry of the contactor or desiccant carry-over. Furthermore, there have been some issues encountered with the described model such as assessing the variation of desiccant concentration and mass flux condensed/vaporised. However the model has provided a valuable quick evaluation tool for the operational performance of liquid desiccant dehumidification systems. As previously stated, a separate paper presented at this conference (Paper ID: SET ) reports the development of computer simulations carried out to evaluate the novel fibre membrane contacting design used in the liquid desiccant air conditioning unit (heat and mass exchange effectiveness) and size the system. 5. CONCLUSIONS This paper has sought to provide an introduction to the EU funded project - Durable Solid Oxide Fuel Cell Tri-generation System for Low Carbon Buildings (TriSOFC), through a project description, a review of the relevant literature and initial modelling work. The system is a novel concept on two levels: (1) the integration of SOFC and liquid desiccant air conditioning technology in a low carbon domestic building environment, and (2) the use of novel materials and construction techniques in the fuel cell stack, and novel materials and design in the liquid desiccant air conditioning system. A concise review of the literature surrounding the topics of fuel cell tri-generation and desiccant based tri-generation systems has been presented. The most significant conclusions from this are: (1) a considerable gap in the literature currently exists surrounding: tri-generation energy systems based on SOFC - liquid desiccant air conditioning technology and fuel cell based trigeneration energy systems in residential applications, (2) the thermal output of a fuel cell CHP system is in good thermal agreement with desiccant regeneration temperature, making them appropriate companion technologies for integration in a trigeneration system concept, and (3) thermal energy utilisation in CHP and tri-generation systems is challenging, and has a large impact on system efficiency. Energy utilisation issues are not so prevalent in simulation and laboratory based projects, however in real world application studies such as TriSOFC they are very much apparent. Initial modelling work focussed on the desiccant air conditioning system components has been presented. Parametric analyses have been carried out, and the parameters with the most influence on performance commented upon. The modelling has been carried out for both the desiccant dehumidifier and regenerator. Further modelling work related to the desiccant air conditioning system that will be used in TriSOFC can be referred to in: Paper ID: SET The TriSOFC system is expected to provide an environmentally friendly way of providing heating, cooling and electricity to low carbon buildings. Future work that can be expected from the project will include system modelling focussing on tri-generation system capacities and efficiencies, experimental results from the desiccant air conditioning and tri-generation system and energetic and economic analysis. This will be the work of future papers. ACKNOWEDGEMENTS The TriSOFC project is supported by the European Commission, under the Fuel Cell and Hydrogen joint Undertaking (FCH-JU) initiative. Please refer to for more information. The authors would also like to thank the EPSRC and DTC in hydrogen, fuel cells and their applications for their continued financial and academic support. 12

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015) 4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015) Multi-stage Series Heat Pump Drying System with Dehumidification Simulation and Experiment Verification Chao

More information

Dynamic performance of a novel dew point air conditioning for the UK buildings

Dynamic performance of a novel dew point air conditioning for the UK buildings *Corresponding author: xudongzhao@nottingham. ac.uk Dynamic performance of a novel dew point air conditioning for the UK buildings... Xudong Zhao *, Zhiyin Duan, Changhong Zhan and Saffa B. Riffat School

More information

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY Xiaoyun Xie, Yidan Tang, Xiaoqin Yi, Shuanqiang Liu,Yi Jiang Department of Building Science and Technology,

More information

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System Feasibility of a Liquid Desiccant Application in an Evaporative Cooling Assisted 100% Outdoor Air System M.H.Kim 1, S.K.Han 1, S.Y. Cho 2, and J.W.Jeong 1* 1 Department of Architectural Engineering, Hanyang

More information

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering July 2018 Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to

More information

Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling

Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling Proc. 2nd International Confirence Solar Air-Conditioning, Tarragona (ES), 18.-19.10.07, CD Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling R.

More information

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations 43rd ANZSES Conference Solar 24, Denedin (NZ), 28.11.-3.11.5, CD Abstract Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations M., W. Saman, K. Vajen* Sustainable

More information

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System M.H.Kim 1, J.Y.Park 1, E.J.Lee 2, and J.W.Jeong 1* 1 Department of Architectural Engineering, Hanyang University,

More information

Modelling the Performance of a Diffusion Absorption Refrigeration System

Modelling the Performance of a Diffusion Absorption Refrigeration System Modelling the Performance of a Diffusion Absorption Refrigeration System Noman Yousuf 1, Etienne Biteau 2, Timothy Anderson 1, Michael Gschwendtner 1 and Roy Nates 1 1 School of Engineering, Auckland University

More information

Numerical study of heat pipe application in heat recovery systems

Numerical study of heat pipe application in heat recovery systems Numerical study of heat pipe application in heat recovery systems *Song Lin, John Broadbent, Ryan McGlen Thermacore Europe, 12 Wansbeck Business Park Ashington, Northumberland NE3 QW, UK E-mail: song.lin@thermacore.com

More information

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance #1 Jaydev S. Bade, #2 Dr. Nitin U. Korde 1 Department of Mechanical Engineering, Savitribai Phule

More information

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant Proceedings of the World Congress on Momentum, Heat and Mass Transfer (MHMT 16) Prague, Czech Republic April 4 5, 216 Paper No. ENFHT 111 DOI: 1.11159/enfht16.111 Experimental Investigation of a Multi

More information

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling Aleksandra Cichoń,*, Anna Pacak, Demis Pandelidis, and Sergey Anisimov Department of

More information

Desiccant Cooling with Solar Energy

Desiccant Cooling with Solar Energy Desiccant Cooling with Solar Energy Gerrit Höfker 1,2, Ursula Eicker 2, Kevin Lomas 1, Herbert Eppel 1 1 De Montfort University Leicester, Institute of Energy and Sustainable Development 2 Hochschule für

More information

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System 4 th International Conference On Building Energy Environment Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System J Y Park H W

More information

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area MMS DEZFOULI, SOHIF MAT, K.SOPIAN Solar Energy Research Institute (SERI, Universiti

More information

White Paper Dehumidification in Humid Climates - A Theoretical Case Study

White Paper Dehumidification in Humid Climates - A Theoretical Case Study White Paper Dehumidification in Humid Climates - A Theoretical Case Study This white paper provides details of a theoretical comparison of operating costs associated with mechanical dehumidification systems

More information

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air Anna Pacak 1,*, Andrzej Jedlikowski 1, Demis Pandelidis 1, and Sergey Anisimov 1 1 Wrocław University of

More information

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3 ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3 1. OBJECTIVE The objective of this experiment is to observe four basic psychrometric processes

More information

Recent Advances in Energy, Environment and Economic Development

Recent Advances in Energy, Environment and Economic Development Experimental Investigation of Solar Hybrid Desiccant Cooling System in Hot and Humid Weather of Malaysia MM SALEHI DEZFOULI, Z HASHIM, MH RUSLAN, B BAKHTYAR, K SOPIAN, A ZAHARIM, S MAT, A RACHMAN, Solar

More information

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou Condensers ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM A. Hadawey, Y. T. Ge, S. A. Tassou 4 7 8 5 3 2 6 1 Produced by: The Centre for Energy and Built Environment

More information

1.1. SCOPE OF THE WORK:

1.1. SCOPE OF THE WORK: Chapter 1: Introduction 1 1. INTRODUCTION 1.1. SCOPE OF THE WORK: Multi-stage refrigeration systems are an area of growing industrial importance in large plants. These systems are known to be large power

More information

NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS

NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS - 1 - NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS S.J. Metcalf, Z. Tamainot-Telto (1) and R.E. Critoph School of Engineering, University of Warwick, Coventry CV4 7AL, UK Abstract: A new

More information

Performance Of The Dehumidification Cycle Of A 3-Fluid Liquid Desiccant Membrane Air-Conditioning System

Performance Of The Dehumidification Cycle Of A 3-Fluid Liquid Desiccant Membrane Air-Conditioning System Performance Of The Dehumidification Cycle Of A 3-Fluid Liquid Desiccant Membrane Air-Conditioning System Devin Storle 1, Mohamed R.H. Abdel-Salam 2, Nader Pourmahmoud 3, Carey J. Simonson 4 1 MSc, University

More information

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2012 Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible

More information

Available online at Energy Procedia 6 (2011) MEDGREEN 2011-LB

Available online at   Energy Procedia 6 (2011) MEDGREEN 2011-LB Available online at www.sciencedirect.com Energy Procedia 6 (2011) 759 768 MEDGREEN 2011-LB Comparison of two methods of improving dehumidification in air conditioning systems: hybrid system (refrigeration

More information

Compression of Fins pipe and simple Heat pipe Using CFD

Compression of Fins pipe and simple Heat pipe Using CFD Compression of Fins pipe and simple Heat pipe Using CFD 1. Prof.Bhoodev Mudgal 2. Prof. Gaurav Bhadoriya (e-mail-devmudgal.mudgal@gmail.com) ABSTRACT The aim of this paper is to identify the advantages

More information

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 11 April 2015 ISSN (online): 2349-6010 CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

More information

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road 517583 AUTONOMOUS QUESTION BANK (DESCRIPTIVE) Subject with Code : Refrigeration and Air Conditioning (16ME8806) Course & Branch:

More information

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview International Journal of Research in Engineering and Innovation Vol-2, Issue-1 (2018), 21-28 International Journal of Research in Engineering and Innovation (IJREI) journal home page: http://www.ijrei.com

More information

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA Ninth International IBPSA Conference Montréal, Canada August 15-18, 25 SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS Chaoqin Zhai 1, Xiaohong

More information

Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement

Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement International Conference Passive and Low Energy Cooling 651 Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement

More information

Impact of indirect evaporative air cooler type on the performance of desiccant systems

Impact of indirect evaporative air cooler type on the performance of desiccant systems Impact of indirect evaporative air cooler type on the performance of desiccant systems Anna Pacak 1,*, Aleksandra Cichoń 1, Demis Pandelidis 1, and Sergey Anisimov 1 1 Wrocław University of Science and

More information

solution, due to the partial vapor pressure difference between the air and the desiccant solution. Then, the moisture from the diluted solution is rem

solution, due to the partial vapor pressure difference between the air and the desiccant solution. Then, the moisture from the diluted solution is rem A Simplified model for estimating the regeneration effectiveness of a counter flow regenerator for a liquid desiccant system M.H. Kim 1, H.J. Cho 1, and J.W. Jeong 1* 1 Division of Architectural Engineering,

More information

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM 111 CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM 7.1 INTRODUCTION Energy is the primary component to run any system in the world. According to

More information

Regenerator Design for Open Cycle Liquid Desiccant Systems Theoretical and Experimental Investigations

Regenerator Design for Open Cycle Liquid Desiccant Systems Theoretical and Experimental Investigations Proc. International Conference Air-Conditioning, Staffelstein (DE), 6.-7.10.2005, pp. 236-240 Design for Open Cycle Liquid Desiccant Systems Theoretical and Experimental Investigations M. Krause, W. Saman,

More information

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points Name: Start time: End time: FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points 1. What are the units of the following quantities? (10 points) a. Enthalpy of a refrigerant b. Dryness fraction of

More information

Ultra Efficient Desiccant Based Evaporative Cooling for Air- Conditioning

Ultra Efficient Desiccant Based Evaporative Cooling for Air- Conditioning Ultra Efficient Desiccant Based Evaporative Cooling for Air- Conditioning Ranga Vamshi and Anurag Bajpai GreenTree Building Energy (P) Ltd., B 67, Sector 67, Noida, UP, India. Problem Statement: Air-conditioning

More information

Experimental study on mass transfer comparison of two liquid desiccants aqueous solutions

Experimental study on mass transfer comparison of two liquid desiccants aqueous solutions International Conference on Renewable Energies and Power Quality (ICREPQ ) Cordoba (Spain), th to th April, 0 exçxãtuäx XÇxÜzç tçw céãxü dâtä àç ]ÉâÜÇtÄ (RE&PQJ) ISSN 1-03 X, No., April 0 Experimental

More information

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant Ravi Verma 1, Sharad Chaudhary 2 1, 2 Department of Mechanical Engineering, IET

More information

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates Purdue University Purdue e-pubs International High Performance Buildings Conference School of Mechanical Engineering 2014 Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for

More information

Humidity Control Systems for Civil Buildings in Hot Summer and Cold. Winter Zone in China

Humidity Control Systems for Civil Buildings in Hot Summer and Cold. Winter Zone in China Humidity Control Systems for Civil Buildings in Hot Summer and Cold Winter Zone in China Xiaoping Yu Doctoral Candidate Chongqing University of Science & Technology Chongqing, China, 400042 xiaoyup@163.com

More information

System Modeling of Gas Engine Driven Heat Pump

System Modeling of Gas Engine Driven Heat Pump Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 01 System Modeling of Gas Engine Driven Heat Pump Isaac Mahderekal shenb@ornl.gov

More information

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a CHAPTER 9 REFRIGERATION & AIR-CONDITIONING YEAR 2012 ONE MARK Common Data For Q. 1 and Q.2 A refrigerator operates between 120 kpa and 800 kpa in an ideal vapour compression cycle with R-134a as the refrigerant.

More information

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY MASS & E ERGY BALA CES I PSYCHROMETRIC PROCESSES EXPERIME T 3 1. OBJECTIVE The object of this experiment is to observe four basic psychrometric processes

More information

FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT

FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT Sivakumar.N a*, Agathiyan.V, Dhanush.S, Gokulnath.V, Jagadhesan.R b, c, d, e UG Scholar, Department of Mechanical Engineering, Gnanamani College

More information

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING V. Vakiloroaya*, J.G. Zhu, and Q.P. Ha School of Electrical, Mechanical and Mechatronic Systems,

More information

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump IOP Conference Series: Earth and Environmental Science PAPER OPEN ACCESS Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump To cite this article: Yefeng Liu et al 2018 IOP

More information

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Experimental study of a novel dew point indirect evaporative cooler

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Experimental study of a novel dew point indirect evaporative cooler Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland Paper ID 0232 ISBN: 978-83-7947-232-1 Experimental study of a novel dew point indirect evaporative cooler Wenhua Chen, Zhiwei Zhang, Jiayu Li,

More information

Heat pump and energy recovery systems

Heat pump and energy recovery systems SBS5311 HVACR II http://ibse.hk/sbs5311/ Heat pump and energy recovery systems Ir. Dr. Sam C. M. Hui Faculty of Science and Technology E-mail: cmhui@vtc.edu.hk Oct 2017 Contents Basic concepts Air-to-air

More information

K.F. Fong *, C.K. Lee, T.T. Chow

K.F. Fong *, C.K. Lee, T.T. Chow Investigation on radiative load ratio of chilled beams on performances of solar hybrid adsorption refrigeration system for radiant cooling in subtropical city K.F. Fong *, C.K. Lee, T.T. Chow Building

More information

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM Sachin Kumar 1, Vicky Ranga 2 1Assistant Professor, Department of Mechanical Engineering, Jagan Nath University Jhajjar, Haryana, India. 2Scholar.

More information

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger Chetan Papade Department of Mechanical Engineering N.K.Orchid college of Engg.& Tech., Solapur, Maharashtra,

More information

Shortcut Model for Predicting Refrigeration Cycle Performance

Shortcut Model for Predicting Refrigeration Cycle Performance 17 A publication of CHEMICAL ENGINEERING TRANSACTIONS VOL. 5, 15 Guest Editors: Petar Sabev Varbanov, Jiří Jaromír Klemeš, Sharifah Rafidah Wan Alwi, Jun Yow Yong, Xia Liu Copyright 15, AIDIC Servizi S.r.l.,

More information

Optimization of Moisture condensation rate of Liquid Desiccant Dehumidifier through Genetic Algorithm

Optimization of Moisture condensation rate of Liquid Desiccant Dehumidifier through Genetic Algorithm International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: 0974-4290 Vol.7, No.01, pp 400-407, 2014-2015 Optimization of Moisture condensation rate of Liquid Desiccant Dehumidifier through Genetic

More information

Elmer, Theo (2015) A novel SOFC tri-generation system for building applications. PhD thesis, University of Nottingham.

Elmer, Theo (2015) A novel SOFC tri-generation system for building applications. PhD thesis, University of Nottingham. Elmer, Theo (2015) A novel SOFC tri-generation system for building applications. PhD thesis, University of Nottingham. Access from the University of Nottingham repository: http://eprints.nottingham.ac.uk/30516/1/theo_elmer_phd_thesis_hardbound

More information

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE Journal of Sustainability Science and Management Volume 9 Number 1, June 2014: 150-155 ISSN: 1823-8556 Penerbit UMT PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE ARFIDIAN

More information

seasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former

seasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former A study on reducing the energy demand of a liquid desiccant dehumidifier with a radiant panel system Tae Ha Leigh, 1 Dae Uk Shin, 1 Goo Sang Joe, 1 Min Gi Kim, 1 Myoung Souk Yeo, 2 and Kwang Woo Kim 2,*

More information

Energy Performance of a Desiccant and Evaporative Cooling-assisted Airconditioning System under Various Climatic Conditions in China

Energy Performance of a Desiccant and Evaporative Cooling-assisted Airconditioning System under Various Climatic Conditions in China Energy Performance of a Desiccant and Evaporative Cooling-assisted Airconditioning System under Various Climatic Conditions in China S. Y. Li 1, H. S. Lim 1, J. H. Shin 1, M. S. Jo 1, and J. W. Jeong 1

More information

Potential and Simulation of Open-Cycle Solar-Assisted Climatisation-Plants in Single-Family-Houses

Potential and Simulation of Open-Cycle Solar-Assisted Climatisation-Plants in Single-Family-Houses Proc. International Conference Solar Air-Conditioning, Staffelstein (DE), 6.-7.10.2005, pp. 236-240 Potential and Simulation of Open-Cycle Solar-Assisted Climatisation-Plants in Single-Family-Houses R.Heinzen,

More information

Review on Waste Heat Recovery Techniques in Air Conditioning Application

Review on Waste Heat Recovery Techniques in Air Conditioning Application International Journal of Current Engineering and Technology E-ISSN 2277 4106, P-ISSN 2347 5161 2016 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Review Article Review

More information

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor? Code No: RR410305 Set No. 1 IV B.Tech I Semester Regular Examinations, November 2006 REFRIGERATION & AIR CONDITIONING (Mechanical Engineering) Time: 3 hours Max Marks: 80 Answer any FIVE Questions All

More information

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid Simulation Analysis of Compression Refrigeration Cycle with Different Refrigerants P.Thangavel, Dr.P.Somasundaram, T.Sivakumar, C.Selva Kumar, G.Vetriselvan Abstract --- In this analysis, the performance

More information

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2016 Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent

More information

CASE STUDIES OF THERMALLY DRIVEN HEAT PUMP ASSISTED DRYING. Minh Cuong Tran, Jamy Logie, Bruno Vanslambrouck, Martijn van den Broek

CASE STUDIES OF THERMALLY DRIVEN HEAT PUMP ASSISTED DRYING. Minh Cuong Tran, Jamy Logie, Bruno Vanslambrouck, Martijn van den Broek CASE STUDIES OF THERMALLY DRIVEN HEAT PUMP ASSISTED DRYING Minh Cuong Tran, Jamy Logie, Bruno Vanslambrouck, Martijn van den Broek Department of Flow, Heat and Combustion Mechanics, Ghent University UGent,

More information

EVALUATION OF A LIQUID DESICCANT AIR CONDITIONING SYSTEM WITH SOLAR THERMAL REGENERATION

EVALUATION OF A LIQUID DESICCANT AIR CONDITIONING SYSTEM WITH SOLAR THERMAL REGENERATION EVALUATION OF A LIQUID DESICCANT AIR CONDITIONING SYSTEM WITH SOLAR THERMAL REGENERATION Stephen J. Harrison, Ph.D., P.Eng. Solar Calorimetry Laboratory Queen s University Kingston, Canada Overview Main

More information

For an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure.

For an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure. 1 PSYCHROMETICS Psychrometry is the study of the characteristics of moist air. We will see soon that evaporation of moisture from the skin can have a significant impact on thermal comfort. The rate of

More information

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers e-issn 2455 1392 Volume 2 Issue 5, May 2016 pp. 108-116 Scientific Journal Impact Factor : 3.468 http://www.ijcter.com Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl

More information

A Statistical Analysis of a Liquid Desiccant Dehumidifier/Regenerator in an Air Conditioning System

A Statistical Analysis of a Liquid Desiccant Dehumidifier/Regenerator in an Air Conditioning System Int. J. of Thermal & Environmental Engineering Volume 5, No. 1 (013) 41-50 A Statistical Analysis of a Liquid Desiccant Dehumidifier/Regenerator in an Air Conditioning System Abdulrahman T. Mohammad *,

More information

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile Available online at www.pelagiaresearchlibrary.com Advances in Applied Science Research, 2013, 4(5):232-237 ISSN: 0976-8610 CODEN (USA): AASRFC Performance analysis of ejector refrigeration system with

More information

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

S.A. Klein and G.F. Nellis Cambridge University Press, 2011 12.A-1 A mixture of helium and water vapor is flowing through a pipe at T= 90 C and P = 150 kpa. The mole fraction of helium is y He = 0.80. a.) What is the relative humidity of the mixture? b.) What is

More information

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way 1 CHAPTER I INTRODUCTION In the modern life, electronic equipments have made their way in to practically every part, which is from electronic gadgets to high power computers. Electronic components have

More information

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning ISBN 978-93-84468-94-1 International Conference on Education, Business and Management (ICEBM-2017) Bali (Indonesia) Jan. 8-9, 2017 An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery

More information

XERIC. Prof. Dr. Ing. Gilbert M. Rios Head WP5 / Dissemination - Communication

XERIC. Prof. Dr. Ing. Gilbert M. Rios Head WP5 / Dissemination - Communication XERIC Prof. Dr. Ing. Gilbert M. Rios Head WP5 / Dissemination - Communication This project has received funding from the [European Union s Horizon 2020 research and innovation programme under grant agreement

More information

THE HEAT PUMP CHOICE OF PROFESSIONALS

THE HEAT PUMP CHOICE OF PROFESSIONALS THE HEAT PUMP CHOICE OF PROFESSIONALS T H E E N E R G Y E F F I C I E N T H E AT I N G S Y S T E M TIME FOR ENERGY EFFICIENT AND INNOVATIVE SOLUTIONS Expectations of consumers are changing. With the high

More information

Makatec. Spiral Heat Exchanger. for Heating and Cooling

Makatec. Spiral Heat Exchanger. for Heating and Cooling Makatec Spiral Heat Exchanger for Heating and Cooling Outline Introduction of the Makatec GmbH and Makatec Apparate GmbH Technologies Heat Exchanger (HEX) Applications of the HEX Role in the Project WP

More information

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger Abstract Shoeb J. Inamdar 1 H.S. Farkade 2 M. Tech student. (Thermal Engineering) 1, Asst. Professor 2 Department of Mechanical

More information

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation Marco Alexandre Onofre Dias This paper presents a model that was implemented

More information

Enhancement of the Separate Sensible and Latent Cooling Air-Conditioning Systems

Enhancement of the Separate Sensible and Latent Cooling Air-Conditioning Systems Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2010 Enhancement of the Separate Sensible and Latent Cooling Air-Conditioning

More information

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning Available online at www.sciencedirect.com Systems Engineering Procedia () 6 International Conference on Risk and Engineering Management (REM) Thermodynamic analysis of air cycle refrigeration system for

More information

Review of flow-through design in thermoacoustic refrigeration

Review of flow-through design in thermoacoustic refrigeration Review of flow-through design in thermoacoustic refrigeration ABSTRACT Bammann T.C., Howard C.Q., Cazzolato B.S. School of Mechanical Engineering, The University of Adelaide, Australia The design and functionality

More information

Access from the University of Nottingham repository: %20paper_v8.

Access from the University of Nottingham repository:  %20paper_v8. Chen, Ziwei and Bai, Hongyu and Ye, Zihao and Zhu, Jie (2016) Experimental study of a membrane-based dehumidification cooling system. In: International Symposium of Heat Transfer and Heat Powered Cycles

More information

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

ZONE MODEL VERIFICATION BY ELECTRIC HEATER , Volume 6, Number 4, p.284-290, 2004 ZONE MODEL VERIFICATION BY ELECTRIC HEATER Y.T. Chan Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong, China ABSTRACT Selecting

More information

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger "COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger" 1 Prof.Gaffar G.Momin, 2 Sagar B. Tupe, 2 Swapnil A. Parate 2 Omkar G. Yewale 2 Aakash P.

More information

Multiphase-Simulation of Membrane Humidifiers for PEM Fuel Cells

Multiphase-Simulation of Membrane Humidifiers for PEM Fuel Cells Multiphase-Simulation of Membrane Humidifiers for PEM Fuel Cells STAR Global Conference Sebastian Bilz, Vladimir Buday, Carolus Gruenig, Thomas von Unwerth Vienna, March 17-19, 2014 1 CFD Simulation of

More information

DESIGN AND SIMULATION OF A SOLAR ASSISTED DESICCANT-BASED AIR HANDLING UNIT

DESIGN AND SIMULATION OF A SOLAR ASSISTED DESICCANT-BASED AIR HANDLING UNIT 8th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics DESIGN AND SIMULATION OF A SOLAR ASSISTED DESICCANT-BASED AIR HANDLING UNIT Angrisani G.*, Sasso M., Roselli C. and Stellato

More information

EXPERIMENTAL PERFORMANCE ANALYSIS OF AN AMMONIA-WATER DIFFUSION ABSORPTION REFRIGERATION CYCLE

EXPERIMENTAL PERFORMANCE ANALYSIS OF AN AMMONIA-WATER DIFFUSION ABSORPTION REFRIGERATION CYCLE EXPERIMENTAL PERFORMANCE ANALYSIS OF AN AMMONIA-WATER DIFFUSION ABSORPTION REFRIGERATION CYCLE Najjaran A. Freeman J. Ramos A. Markides C.N.* *Author for correspondence Department of Chemical Engineering

More information

Vapour Compression-Absorption Cascade Refrigeration System- Thermodynamic Analysis

Vapour Compression-Absorption Cascade Refrigeration System- Thermodynamic Analysis Vapour Compression-Absorption Cascade Refrigeration System- Thermodynamic Analysis PARBHUBHAI R.TAILOR Department of Mechanical Engineering Sardar Vallabhbhai National Institute of Technology Surat,Gujarat-395007,INDIA

More information

POTENTIAL OF NON - AZEOTROPIC REFRIGERANT MIXTURE AS WORKING REFRIGERANT IN HOT WATER HEAT PUMPS. FJ Smit and JP Meyer

POTENTIAL OF NON - AZEOTROPIC REFRIGERANT MIXTURE AS WORKING REFRIGERANT IN HOT WATER HEAT PUMPS. FJ Smit and JP Meyer POTENTIAL OF NON - AZEOTROPIC REFRIGERANT MIXTURE AS WORKING REFRIGERANT IN HOT WATER HEAT PUMPS FJ Smit and JP Meyer Research Group for Heating and Cooling Technology, Laboratory for Energy, PO Box 524,

More information

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential

More information

GAS CONDENSING TECHNOLOGY

GAS CONDENSING TECHNOLOGY GAS CONDENSING TECHNOLOGY Authors: Ing. Dipl.-Ing. (FH) Markus Telian, Dipl.-Ing. Stefan Müller Hovalwerk AG Marketing and Development Vaduz, Principality of Liechtenstein. Abstract Hoval has realized

More information

Adsorption refrigeration system using waste heat

Adsorption refrigeration system using waste heat Adsorption refrigeration system using waste heat 1 RISHI SREEKUMAR, 2 SANJEEV SINGH, 3 HIMANSHU SHEKHAR, 4 RAUSHAN KUMAR, 5 Dr. R. S. BINDU 1,2,3,4 BE Students, 5 Professor Mechanical Engineering Department

More information

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System A D Parekh, and P R Tailor Abstract Because of damaging effect of CFC refrigerants on stratospheric

More information

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2006 Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps

More information

Experimental Performance of Solar Collector cum Regenerator for Coupling with a Liquid Desiccant Cooling System

Experimental Performance of Solar Collector cum Regenerator for Coupling with a Liquid Desiccant Cooling System Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2016 Experimental Performance of Solar Collector cum Regenerator for Coupling

More information

Clemens Felsmann 1, Jean Lebrun 2, Vincent Lemort 2 and Aad Wijsman 3 ABSTRACT INTRODUCTION METHODOLOGY

Clemens Felsmann 1, Jean Lebrun 2, Vincent Lemort 2 and Aad Wijsman 3 ABSTRACT INTRODUCTION METHODOLOGY Eleventh International IBPSA Conference Glasgow, Scotland July 27-30, 2009 TESTING AND VALIDATION OF SIMULATION TOOLS OF HVAC MECHANICAL EQUIPMENT INCLUDING THEIR CONTROL STRATEGIES. PART II: VALIDATION

More information

Reducing the Carbon Footprint of Existing Domestic Heating: A Non-Disruptive Approach

Reducing the Carbon Footprint of Existing Domestic Heating: A Non-Disruptive Approach EEDAL 2009 16-18 June 2009 Reducing the Footprint of Existing Domestic Heating: A Non-Disruptive Approach Martin O Hara Danfoss Randall Limited Abstract There is insufficient time between today and 2020

More information

Performance Analysis of Solar Assisted Cascade Refrigeration System of Cold Storage System

Performance Analysis of Solar Assisted Cascade Refrigeration System of Cold Storage System Performance Analysis of Solar Assisted Cascade Refrigeration System of Cold Storage System Dr. Nimai Mukhopadhyay 1, ER. Someshwar Chowdhury 2 Assistant Professor, Dept. of M. E., Jalpaiguri Government

More information

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad- 500 043 B.Tech (III II SEM) MECHANICAL ENGINEERING REFRIGERATION AND AIR CONDITIONING Prepared by, Dr. CH V K N S N Moorthy, Professor

More information

developed, and parametric studies are conducted with the model. Based on the parameter study results, a dehumidification performance diagram is propos

developed, and parametric studies are conducted with the model. Based on the parameter study results, a dehumidification performance diagram is propos Evaluation of A Plate Desiccant Outdoor Air-conditioning System Utilizing Cogenerated Hot Water Using A Numerical Model T. Baba 1, B. Park 1 1, *1, and T. Nagai 1 Department of Architecture, Tokyo University

More information