FAX:
|
|
- Clarence Mason
- 6 years ago
- Views:
Transcription
1 Temperature and Humidity Test Chamber Technical Data (Whole Picture of the product) Draft man: David Dai Draft Time:28/09/2015 ADD: Sanwood Industrial Park, YuanJiangYuan, Changping, Dongguan, Guangdong,china TEL: FAX: Business phone:: skype:david dai Web:
2 The reason for choosing SANWOOD Equipment Technical Features A.USB disk recording function, do not need recorder; B.The wide range of temperature and humidity,the standard model can reach 60 (40) 10%RH; 1. Refrigerant servo valve control flow calculation, energy saving more than 30%; 2. High temperature and high humidity test to prevent condensation of moisture and drip,the technology ranks first in this industry 3. Low temperature working state, the heater does not participate in the work, through the PWM technology to control the refrigerant flow and flow direction, the cooling pipe, cold bypass pipe, heat bypass pipe three to flow regulation, to achieve automatic constant temperature of the studio. This method can reduce the energy consumption by 40%; 4. Temperature and humidity control of synchronous lifting slope, no drop, no condensation; 5. Low noise, only 55dB at low temperature testing; 6. Refrigeration advantages: 7. Low temperature control method of traditional equipment: Ø Constant operation of refrigeration compressor + Heating PID control Refrigeration and heating temperature offset achieve dynamic balance, wasting a lot of energy. Realization of low temperature energy saving operation with new PWM cold control technology Low temperature working state, the heater does not participate in the work, through the PWM technology to control the refrigerant flow and flow direction, the cooling pipe, cold bypass pipe, heat bypass pipe three to flow regulation, to achieve automatic constant temperature of the studio. This method can reduce the energy consumption by 40%. The technology based on the United States Sporlan company customized model PWM control valve:
3 Core Spare Parts: German Schneider Contactor German Schneider Thermal Relay Izumi Japanese Rely high and low voltage protection switch Yangming solid state relay songqi Temperature sensor Dongyuan Circulating Motor Sporlan refrigeration solenoid valve Taiwan Jianli stainless steel wind wheel Taiwan FeiYang Heating Tube Taiwan Zhongli evaporator Mobile castors Rack oil separator France Tecumseh Compressor South Korean Controller
4 Main spare parts list: NO Material name Origin / brand Model Quantity life-span 1 Temperature and humidity South Korea controller SAMWON TEMI years 2 AC contactor German Schneider LC1-D years 3 Thermal Relay German Schneider LRD-08KN 2 10 years 4 Intermediate Relay Izumi Japanese RU4S-A years 5 Time Relay Taiwan AnLiang AH years 6 Over Temperature South Korea 10 years TS-320S 2 Protection RAINBOW 7 Solid State Relay Taiwan Yangming SSR-40DA 6 8 years 8 Temperature and Humidity 15 years Taiwan Songqi PT100 2 Sensor 9 Lamp LED 12V\18W 2 15years 10 Leakage switch South Korea LG DP-40A 1 15years 11 Signal Indicator Taiwan Tiande AD16-22D/S years 12 Flash buzzer Taiwan Tiande AD16-22SM 1 10 years 13 Switching Power Supply Taiwan Mingwei NES years 14 No fuse switch German Schneider LC-1P20A 2 10 years 15 Button Switch Taiwan Tiande AD-22D/S years 16 Circulating Motor Taiwan Dongyuan DL-220V90W 1 10 years 17 Circulating Wind Wheel Taiwan Jianli 7CL 1 10 years 18 Heating Tube Taiwan Feiyang Customized 2 10 years 19 New Western Hills 15 years Pump Motor DP joint venture 20 Liquid Temperature RAINBOW South 15 years RA-10KG 1 Controller Korea RAINBOW 21 France Tecumseh 15 years 2P compressor TFH-2480Z-T 2 Compressor 22 Condenser Taiwan Zhongli ZL-2P 2 10 years 23 Evaporator Taiwan Zhongli ZL-2P 2 15 years 24 Condenser fan Germany EBM 4E-350-Z 1 10 years 25 Drying filter Danfoss 083S 2 15 years 26 Expansion valve Danfoss TS-2S 2 15 years 27 Solenoid valve Danfoss DA years 28 Refrigerant AmericanLianxing R404A/R years 29 Refrigeration oil BritishBingxiong RL32H 2 15 years 30 Oil separator America ALCO S years 31 Vacuum Heating Glass Taiwan DSD Customized 1 15 years 32 Cooling Fan Taiwan Jianzhun EB years 33 Lock America Shangkun SK years 34 Casters Taiwan Zhide Customized 4 15 years 35 Horizontal Wheel Taiwan Zhide Customized 4 15 years
5 Main technical parameters: 1. Equipment performance Product performance Air cooling, no-load, machine air cooling type at room temperature 25, or water temperature at 25 Name temperature and humidity test chamber Model SMC-225-CC Inner dimension 50 x75 x60cm ( W x H x D ) Inner volume 225L Outer dimension 80 x 160 x145 cm ( W x H x D ) Temperature Range -70 ~180 Humidity Range 10%~98% Heating Rate 3.0 ~5.0 /min Cooling rate 0.7 ~1.5 /min Temperature and degree distribution ±1 uniformity Temperature controlled wave motion ±0.1 Temperature deviation ±1 Temperature stability time 10min; Humidity distribution uniformity ±2% Humidity control fluctuation ±2% Humidity deviation ±2% Humidity stability time Weight 10min 360KG 2. Mechanical structure design 2-1. Inner box material Heat resistant stainless steel plate welding(sus #304) 2-2. Outer box material The outer box adopts galvanized high baking powder or cold hot resistant stainless steel plate 2-2. Main structure design The sheet metal area, circuit area, frozen zone, water zone, the four parts Heat/Cold storage material High efficiency aluminum alloy thermal storage production capacity and cold heat exchange capacity of super efficiency Observation window Installation of rectangular multi - layer insulating glass observation window (570 x 420mm) to install energy-saving LED lighting source 2-5. Sample rack bearing A layer of no more than 30 kg 2-6. Sample rack moving mode The sample rack is mounted on the bottom of the box body and moves up and down. 2-7.Insulation layer Heat insulation layer flame retardant PU+Heat insulation glass wool(10.0cm Insulation layer) 2-8. Box frame Adjustable grid frame and 2 stainless steel strip grid (Disk frame 5.0cm distance) 2-9.Machine positioning The machine bottom is equipped with 4 high load bearing blocks and the PU horizontal angle wheel is in favor of moving the machine Box body structure Taiwan original plane embedded rotating handle Hinge: the original Japanese imports, can prevent the box door any shaking, the material is #304 SUS;
6 The use of energy-saving 18W LED, can be clearly seen in the box four corner test items; 3. Temperature and humidity electric heating cycle system 3-1Electric heating cycle system Temperature mining special moisture and heat dissipation design, stainless steel extended axis motor 3-2 Circulating wind High / low temperature aluminum alloy multivane circulating fan 3-3. Electric control mode of heat storage Balanced temperature control of S.S.R P.I.D zone Microcomputer control, pre cooling preheating temperature conversion 3-4. Structure microcomputer control control, output power from the computer to achieve high accuracy and high efficiency. The U type fin type high-speed heating electric heater Fully independent system does not affect the frozen and control line 3-5. Auto-Control Calculation of the heat content of the test object with the heating rate Electronic and position method for micro wetting system The wet barrel is made of stainless steel, and with a water level observation window Double guarantee device for overheat and overflow Wet and desiccant system is completely independent Humidification system The water level control adopts the mechanical float ball water raft,antielectronic type of mistake For wet water use automatic replenishment system with filter, the buyer does not need to manually add water. The use of non recycling water system Independent refrigeration compression system 3-7.Desiccant system Dew point temperature (ADP) laminar flow contact and desiccant method for evaporating vessel 4.Refrigeration system: Using binary-type refrigeration systems, good efficiency, energy-saving 4-1. Refrigerating apparatus Europe and high efficiency ultra-low temperature refrigeration compressor (air cooling mode) 4-2. Heat exchanging devices The design of the SWEP plate cold coal exchange with high efficiency which is more traditional.. Automatic adjustment of cold coal flow by computer,effectively take the heat load of the sample and the German / Japanese technology 4-3. Heating load regulation simultaneously,compared with the traditional design, the stability and reproducibility of the control is high and the efficiency of power saving is achieved Condenser Using water cooling or air cooling heat dissipation method for the large system of the water - collecting pipe type and the tube type 4-5.Super efficiency refrigeration control refrigerant The refrigerant pipes are welded with the nitrogen pressure and leak test Evaporator High efficiency components using slope type evaporator,(ac&r double turbulent type aluminium fins)
7 4-7. Standard modular design Compatibility and interoperability of components of high quality stability 4-8. Extended Performance The TEMI1500 control system can be reserved for isothermal control of liquid nitrogen valve LN2V & FV control interface Extensions Work long hours with low evaporator icing automatic defrost circuit 4-10.Special functions Multi-wing circulating fan, forced convection air flow to improve the efficiency of uniform temperature 4-11.Special functions The test area is controlled by P.I.D.+S.S.R. microcomputer, which can achieve the control precision Refrigerant United States DuPont green refrigerant R404a and R23a Expansion valve(america SPOLAN),Solenoid valve(italy 4-13.Auxiliary Original CASTEL),Filter(America SPORLAN),Pressure controller(anglo American RANCO),Oil separator(europe ALCO) etc refrigeration accessories are imported parts 5. Control system((temi-1500 ) 5-1.Controller combination A. Controller type TEMI-1500 B. Controller origin South Korea SAMWON C.Temperature sensor JIS RTD PT 100 Ω 2 Platinum sensor 5.7 inch LCD touch control screen, groups of 120 programming, 9999 cycles D. Controller function set And with a number of PID control, the display screen 240 x 320 point wide viewing angle, high contrast with the large LCD display screen a. Temperature resolution:0.1 E. Controller specification b. Operation mode: Program running, Set operation c. Equipment working time cumulative timer d. PID control mode F T e m p e r a t u r e A microcomputer multifunctional automatic linear compensation and correction, c o n v e r t e r temperature converter a. The control software on screen, the screen directly touch options, including boot settings,loop, program, display screen, auxiliary setting, system opening program capacity and control function G. Screen display b. With temperature setting, humidity setting indicator c. Can display the current state of execution, temperature setting, time setting, the rest time, the remaining number of cycles d. Function of fault condition and fault elimination method in English,machine can not started with fault unsolved a. Can be used by the amount of the program: the maximum 999 groups b. Can be repeated orders: each command can be 9999 times c. Time setting 0~9999Hr59min H. Program capacity and control d. Have an appointment start function function e. Key and screen lock (LOCK) function f. Temperature defrosting time setting g. Attached RS232 communication interface and USB interface.
8 h. The temperature, time and the number of cycles can be set Controller main function A.Temperature analytic ability 0.01 B. Temperature control accuracy ± 0.2 C. Set time capacity 0 H 1 M ~ 9999 H 59 M D. Display language Chinese (Traditional) / English E. Reservation start-up time Reservation time setting function. F. Calculation control Automatic temperature program change control and program link control. G. Screen display Color real time curve display screen (set). Test curves show, no time limit, sampling rate automatically adjust H. Software device for fault record Control of storage / record / analysis when the machine is maintained. I.Controller deviation setting Intelligent digital temperature deviation "return to zero" J. Call back after selection Call back after the blackout "continue" "to" "stop" setting. Automatic adjustment of the cold coal flow, effectively take the heat load of the sample to be measured with the German / Japanese K. Control software technology Compared with the traditional design, the stability and reproducbility of the control is high and the efficiency of power saving is achieved. L. Upper and lower limit of Set up the test procedure, and automatically set the upper and lower limits of temperature protection the low temperature protection. M. Power failure memory device Ensure that the stored procedures in the power failure to maintain memory data I. Security permission settings Machine operation password permission settings O. Mode Selection Programmable control mode 6. Safety protection system 6-1. Leakage / burst protection Leakage protection of electric wave of leakage protection Prevention of lightning protection Controller AC power supply is equipped with the arrester ZRN device AC Power Supply,Three phase power supply. Reverse phase protection 6-3. Overload protection device and current load over load (over load) High temperature and high temperature protection operation control of high temperature and low temperature protection setting 6-4. Compressor protection Cold media pressure protection and overload protection device. Cold media pressure protection and overload protection device. Compressor internal overheat protection Compressor high and low voltage protection Compressor startup exception protection Compressor oil pressure difference protection 6-5. Protector 1 group humidification barrel dry protection switch 1 groups of low water level protection 1 group of heating system protection switch Heater short circuit protection Temperature and humidity over temperature balance device 6-6. Fault exception protection Fault exception occurs when the control power supply cut off and cause of the malfunction indication and alarm output signal
9 7.Standard configuration: 7-1.Test hole ψ100mm a hole on the left side of the body attached to a stainless steel manhole covers, silicone plugs Over-temperature protection LED digital microscopic computer controller, preventing the sample temperature too high or too low 7-3. Fuse Backup fuse 7-4. Instruction manual Controller instruction manual, Operating instruction manual Product qualification certificate 7-5.Other standard configuration 8. Use requirements 8-1.Environmental requirements 8-2. Site requirements 4 Sample frame 2 groups of adjustable spacing 50mm rack rail 4 Adjustable horizontal cup wheels 6 meters 5X6 square low impedance rubber cable Allowable temperature range 0~25 Performance guarantee range 5~25 Relative humidity: 85%RH Air pressure:86kpa~106kpa Cooling circulating water: Null Compressed air: Null Smooth ground, well ventilated, non flammable, explosive, corrosive gas and dust Near no strong electromagnetic radiation source A floor drain near the equipment Ground bearing capacity: not less than 800KG/ square meters Reserved space for proper maintenance. When the equipment works, the temperature of the environment should be kept within 0 ~ +4 (not frozen).when the equipment works, the temperature of the environment should be kept within 0 ~ +4 (not frozen). 8-3.Requirements for When the equipment works, the temperature of the environment should be kept storage environment within 0 ~ +4 (not frozen). The temperature is below 0 ~ +4 in the north of the room can not be frozen phenomenon, to ensure that the interior is not frozen, to ensure the normal use of equipment. 9 Power supply system: the system power fluctuation is not greater than 10% Model SMC-225-CC series Power Quality Assurance Voltage 220V±10 Rated current 45A 5.5KW In order to further improve the company's product and company management level, to provide users with high brand, high quality, high efficiency, world-class high-service environmental testing equipment, the company strictly in accordance with IS09001: 2008 version of the standard of quality assurance system operation. Products manufactured before the quality department need to
10 undergo a quality inspection of about a week, to ensure product quality and interests of users
11
12
Rapid temperature Change
Rapid temperature Change test box Technical Data Draft man: David Dai 13798916526 Draft Time:28/09/2015 ADD: Sanwood Industrial Park, YuanJiangYuan, Changping, Dongguan, Guangdong,china TEL: +86-769-81182799
More informationUV Weather Resistance Test Chamber Technical Data
UV Weather Resistance Test Chamber Technical Data (Whole Picture of the product) Draft man: Emily Yan +86-18819094376 Draft Time:13/01/2016 ADD: Sanwood Industrial Park, YuanJiangYuan, Changping, Dongguan,
More informationTechnical Specification of High and Low Temperature Altitude Test Chamber
Technical Specification of High and Low Temperature Altitude Test Chamber Model: KU-504L Manufacturer: KOMEG Technology Ind Co.,Ltd 1 / 8 Ⅰ. Control methods and characteristics No:16081010 Edition:00 High
More informationCompact Ultra Low Temperature Chamber
Compact Ultra Low Temperature Chamber MC-712R 812R CAT.NO.E14140-Z1804 High performance and reliability come in a compact package, covers wide range of temperature testing needs, from ultra-low temperature
More informationMINI BENCH TOP CHAMBER MODEL: MI-80-A-H
MINI BENCH TOP CHAMBER MODEL: MI-80-A-H Introduction: The Mini Bench top chambers are compact sized humidity chambers which can be placed on a work bench or on the optional stand provided. These chambers
More informationSeries of all-purpose physical and chemical environmental cabinets meeting the diverse needs of laboratories and research facilities.
Series of all-purpose physical and chemical environmental cabinets meeting the diverse needs of laboratories and research facilities. The Laboratory chambers incorporate a number of sophisticated technologies
More informationElmatik AS, Türi 9, Tallinn Estonia tel tel fax
Stress of 5/min. or more achieved with the large-capacity 1800L models. A faster temperature and humidity chamber with 1800 L capacity has been developed for reliability testing of increasingly large display
More informationElmatik AS, Türi 9, Tallinn Estonia tel tel fax
Speedy and Compact High-Precision Thermal Tests Made Possible This thermal-plate system has been developed to enhance heat conductivity to the specimen. When the specimen is placed on the thermal plate,
More informationThermal Shock Chamber TSE 11
Thermal Shock Chamber TSE 11 CAT.NO.E1133-V13 ESPEC offers a compact, but high performance thermal shock chamber ideal for the requirements of test standards of small and low-volume specimen. Equipped
More informationEnvironmental Chambers
Temperature (& ) Chambers Dimensions (TH-G / TH-I / TC-G series) 115 Models Capacity W D H A B TH-G TH-I TC-G TH-G TC-G 180L (6.4cu ft) 1025mm (40.4 ) 1035mm (40.7 ) 1530mm (60.2 ) 450mm (17.7 ) 1230mm
More informationCLIMATE STSAR series. High and low temperature test chamber
CLIMATE STSAR series High and low temperature test chamber 1 Technical specifications Main technical parameters Implementation standards Temperature fluctuation: ±0.5 Temperature uniformity: 2.0 Temperature
More informationFaster Temperature (& Humidity) Chamber
Faster Temperature (& Humidity) Chamber SML2SMU2 SMS2SMG2 CAT.No.E04129-V1209 Stress of 5/min. or more achieved with the large-capacity 1800L models. A faster temperature and humidity chamber with 1800
More informationConstant climate chambers
KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.
More informationUtility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation
Compact design for personal use Ready to network with your computer. Introducing a new lineup of our Bench-top Type (& Humidity) Chamber Series. Our latest models achieve superb performance in a compact
More informationModel MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range
Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range The BINDER MKFT series environmental simulation chamber for low temperature
More informationHeated and Refrigerated Incubators
Heated and Refrigerated Incubators MIR-162-PA MIR-262-PA MIR-154-PA MIR- 254-PA MIR-554-PA us.panasonic-healthcare.com powered by TM Heated and Refrigerated Incubators Panasonic MIR series incubators are
More informationConstant climate chambers
KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.
More informationPROGRAMMABLE TEMPERATURE AND HUMIDITY CHAMBER
Payment: This product is available in our stock, T/T 100% before shipment or by Trade Assurance. Product Feature: Test system design advanced and reasonable, standard manufacturing process, beautiful and
More informationConstant climate chambers
KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.
More informationCompact design for personal use Ready to network with your computer.
Compact design for personal use Ready to network with your computer. Introducing a new lineup of our Bench-top Type (& Humidity) Chamber Series. Our latest models achieve superb performance in a compact
More informationRefrigerated Incubators / Environmental Testing Chambers
Refrigerated Incubators / Environmental Testing Chambers MIR-154 MIR-254 MIR-553 MLR-351H SANYO s MIR and MLR series incubators have been recognized as exceptional units suitable for a wide range of applications.
More informationConstant climate chamber with ICH-compliant illumination
KBF P series (E5.2) Constant climate chambers Constant climate chamber with ICH-compliant illumination The BINDER KBF P constant climate chamber, equipped with ICH-compliant illumination, is the expert
More informationFREEZE DRYER LYOPHILIZER PRODUCTS LABFREEZ INSTRUMENTS CO., LTD
FREEZE DRYER LYOPHILIZER PRODUCTS LABFREEZ INSTRUMENTS CO., LTD Addr1: 2D, Building 3, Century City Chenyue Park, Haidian district BeiJing, China Addr2: No.72 Renmin road, Yuhu district, Xiangtan city,
More informationConstant climate chamber with humidity
KBF series (E5.2) Constant climate chambers Constant climate chamber with humidity The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate
More informationDOUBLE DOOR FREEZER.
DOUBLE DOOR FREEZER www.labocon.com NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation. UPRIGHT FREEZER DOUBLE DOOR LUFD-25-100 SERIES Labocon
More informationForced-air Drying Ovens www.zhichenginstrument.com ISO 9001:2000 ISO13485:2003 High Performance Proven Reliability Advanced Control Description ZXRD/A series forced-air drying ovens manufactured by ZHICHENG
More informationModel MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range
Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range BENEFITS Homogeneous climate conditions thanks to APT.line technology Automatic
More informationS ATION EWORK ST BGA R
BGA REWORK STATIONS INTRODUCTION InterElectronic Hungary Ltd. offers equipments, machines and different materials (ESD) of different production technologies (SMT/THT/LED). Including high quality, special
More informationUltra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32
Ultra Deep Freezers Biomedical Refrigeration I UF -86 C Technology for life 504170_8pages_dometic_UF.indd 1 10/09/08 11:17:32 UF - Ultra Deep Freezers up to -86 C The models UF 455 G & UF 755 G reflect
More informationCustomized Industrial Products
Customized Industrial Products Product Catalog Large Walk-in Type Drying Oven Large Size Autoclave Large Size Fine Oven Targeting Productivity Improvement Yamato offers customization of products based
More informationTemperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI
HumiTherm Ultra Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping Mapping Unit Micro PLC Control Unit Touch Panel Touch Operation Panel PPI HumiTherm Ultra GSM Module
More informationPerformance. TCC-150 provides uniform temperature load, and highlyrepeatable temperature change rate. Conformity to JEDEC JESD22-A104-B standard test
Rapid-Rate Thermal Cycle Chamber TCC-150 CAT.NO.E06132-Z610 Uniform and highly-repeatable temperature change rate. TCC-150 enables specimen temperature ramp control. Advent of the Rapid-Rate Thermal Cycle
More informationBench-Top Type Temperature (& Humidity) Chamber
Bench-Top Type Temperature (& Humidity) Chamber SHSU CAT.NO.E01111-M102 Compact design for personal use, to network with your computer. The Bench-top Type Temperature (& Humidity) Chamber Series features
More informationUtility. High performance by special glass. Supports high-temperature, high-humidity testing
Ultra View Temperature (& Humidity) Chamber PWLPWU CAT.NO.E05128 Full visibility, with improved ease-of-use and greater functionality. High-performance temperature and humidity chambers with a glass viewing
More informationS ATION EWORK ST BGA R
BGA REWORK STATIONS INTRODUCTION INTEON BGA rework systems allows attractive price and high quality performance for lead free process. INTEON BGA rework systems assure an optimum of process stability by
More informationSHAKING WATER BATHS ENGLISH
SHAKING WATER BATHS ENGLISH Display Technical Features Operation Easy to read Large LED temperature display for actual value and setpoint (display resolution 0.1 C) Several values at a glance Large Multi-Display
More informationXRD XRD-1500 High-Temperature Oven. Innovation in Material Science...
XRD-1500 XRD-1500 High-Temperature Oven Innovation in Material Science... New materials science calls for refined tools that enable X-ray research in well-defined environments and under controlled temperature
More informationEnvironmental Stress Chamber AR series
Environmental Stress Chamber AR series CAT.NO.E09141-W1207 Advanced reliability Environmental Stress Chambers for tomorrow's environmental testing needs Achieving reliability requires a system that delivers
More informationSECTION WATER-SOURCE UNITARY HEAT PUMPS
SECTION 23 81 46 WATER-SOURCE UNITARY HEAT PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification
More informationPlasma Freezer with air circulation TC 516 acc. to DIN 58375
These blood plasma storage cabinets are designed for DIN - compliant storage of already frozen blood plasma bags. External Dimensions: B = 600 mm D = 780 mm H = 2000 mm Internal Dimensions: B = 500 mm
More informationWalk in Steam Curing Chamber for Concrete Application. Detailed Working Specifications
Detailed Working Specifications The Chamber with extremely high fabrication standard, high quality of finish, which matches the performance with emphasis on reliability and economy of use. The use of the
More informationEnvironmental Chambers
Temperature & Chambers. Temperature & Chambers - Tabletop type. Fingerprint Development Chamber - Tabletop type. Temperature Chambers. Temperature Chambers - Tabletop type. Clean Temperature & Chambers.
More informationMULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw
Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01
More informationSafety vacuum drying oven for flammable solvents
VDL series 53 Vacuum drying ovens Safety vacuum drying oven for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with
More informationAll series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.
HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types
More informationPrecision Cooling. DataMate3000 Series Precision Cooling Systems for Small Equipment Room IT Application
Precision Cooling DataMate3000 Series Precision Cooling Systems for Small Equipment Room IT Application DataMate3000 Series Air Cooled Precision Cooling System DataMate3000 Series Air Cooled Precision
More informationIndustrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)
UCUF191S-86, UCUF241S-86 and UCUF281S-86 UPRIGHT ULTRACOLD FREEZERS Control and Alarm Features Manual defrost, adjustable control range from -50 C to -86 C. UL/CUL Listed. Factory preset at -80 C. Advanced
More informationLaboratory Deep Freeze Storage Cabinet TC 230 Air circulated
External Dimensions: B = 600 mm D = 650 mm (at -30 C/-40 C: 760 mm) H = 1640 mm (at -30 C/-40 C: 1720mm) Internal Dimensions: B = 500 mm D = 500 mm H = 890 mm Capacity: 300 l Temperaturerange: Optional:
More informationBATHS SHAKERS STIRRERS HOTPLATES INCUBATORS HEATING MANTLES INCUBATORS
BATHS SHAKERS STIRRERS HOTPLATES INCUBATORS HEATING MANTLES INCUBATORS INCUBATORS DFI Series, 36 Liter, 80 Liter, 150 Liter, 240 Liter Incubators DFI-36 DFI-80 DFI-150 DFI-240 Incubator With Forced Convection
More informationStability & Shelf Life
Stability & Shelf Life Test Chambers Lunaire Environmental provides the largest selection of standard size test chambers as well as temperature/humidity ranges to accommodate all required protocols. Our
More informationINTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies
Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER
More informationEnvironmental simulation chamber for complex alternating climate profiles
MKF series (E3.1) Environmental simulation chambers Environmental simulation chamber for complex alternating climate profiles A BINDER environmental simulation chamber of the MKF series is ideally suited
More informationICH110. Climate Chamber. Product specification
Product specification Climate Chamber ICH110 Unparalleled homogeneity of temperature and humidity! For stability testing according to ICH - WHO - EMA - ASEAN - GMP - GLP GCCP. On this page, you can find
More information.2 Section Waste Management and Disposal.
Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3
More informationSunrise the beginning of a brand new day
Sunrise the beginning of a brand new day Choosing a new chamber should be easy you already know what you want. Angelantoni Industrie is now offering the most complete standard line of chambers available
More informationULTRA LOW TEMPERATURE FREEZER. User Manual
ULTRA LOW TEMPERATURE FREEZER User Manual Note:Kaltis reserves the right to modify any parts of this manual without prior notice. 1. No part of this manual may be reproduced in any form, or translated
More informationMedical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345
External Dimensions: B = 530 mm D = 640 mm H = 1600 mm Inside Dimension: Useful space on top Useful space at the bottom B = 450 mm B = 450 mm D = 535 mm D = 535 mm H = 530 mm H = 530 mm Capacity: 280 l
More informationPR / MP I Laboratory / Medicine
Technology for Life Medical SYSTEMS Technology for Life PR / MP I Laboratory / Medicine / Pharmaceutical Refrigerators (with glass door) +5 C +4 C 292.9707.80 02/2013 BIOMEDICAL REFRIGERATION Innovative
More informationClimate chambers with illumination and humidity The BINDER KBWF series shines with its
KBWF series (E5.2) Climate chambers with illumination Climate chambers with illumination and humidity The BINDER KBWF series shines with its homogeneous light distribution with natural illumination from
More informationMedical Refrigerators
Medical Refrigerators B Medical Systems Range Medical Refrigerators are devices intended for the safe storage of laboratory and pharmaceutical preparations at cold temperatures between +4 C and +15 C.
More informationTEMPERATURE SHOCK TEST CHAMBERS
E SHOCK TEST CHAMBERS TEST STANDARDS VARIOUS TEST POSSIBILITIES Thanks to rapid and high-speed temperature change tests, failures on products which will undergo such extreme impacts can be detected in
More informationHigh Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value
High Inlet Temperature Air Dryer Membrane Air Dryer After-Clooler Oil-Water Separator Automatic Value 1 2 3 4 5 6 7 8 9 1 HYD model Control Panel 1. on HYD-150 and smaller - It is equipped with a low pressure
More informationElmatik AS, Türi 9, Tallinn Estonia tel tel fax
Key technology for ensuring reliability Supports the current trend toward higher stress. High accuracy is increasingly demanded in the pursuit of reliability in the field of electronics. Liquid-to-liquidtype
More informationCZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with
More informationICH260C. Climate Chamber. Product specification
Product specification Climate Chamber ICH260C Unparalleled homogeneity of temperature and humidity! For stability testing according to ICH - WHO - EMA - ASEAN - GMP - GLP GCCP. On this page, you can find
More informationCustomers. The core of our innovation. Feeding&Conveying. Drying Dosing Temperature Control Refrigeration Granulation
EN Customers. The core of our innovation Feeding&Conveying Drying Dosing Temperature Control Refrigeration Granulation Piovan Drying Technologies: Desiccant Bed Dryers Dried air is generated by means of
More informationHigh Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.
HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy
More informationDeep Freezers. Freezers. Biomedical Refrigeration I FR / MF
Deep Freezers and Plasma Storage Freezers Biomedical Refrigeration I FR / MF Low-temperature storage of plasma and other blood products at 41 C/ 35 C According to DIN 58375 www.dometic.lu Deep Freezers
More informationDEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE
TECHNOLOGY FOR LIFE DEEP FREEZERS AND PLASMA STORAGE FREEZERS Biomedical Refrigeration I FR / MF Low-temperature storage of plasma and other blood products at 41 C/ 35 C According to DIN 58375 www.dometic.lu
More informationLiquid to Liquid Thermal Shock Chamber TSB 21 TSB 51
Liquid to Liquid Thermal Shock Chamber TSB21TSB51 CAT.NO.E3137-X13 Key technology for ensuring reliability Supports the current trend toward higher stress. High accuracy is increasingly demanded in the
More informationICH750L. Climate Chamber. Product specification
Product specification Climate Chamber ICH750L Unparalleled homogeneity of temperature and humidity! For stability testing according to ICH - WHO - EMA - ASEAN - GMP - GLP GCCP. On this page, you can find
More informationV ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.
HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless
More informationCO 2 Laser. High Reliability and Performance
CO 2 Laser High Reliability and Performance FANUC imagination at work Drives & Motors Quality Through Innovation GE Fanuc is a world leader in CNC technology and has long-term experience in developing
More informationMD-S7000. All Electric Injection Molding Machine NIIGATA MACHINE TECHNO CO.,LTD.
MD-S7000 All Electric Injection Molding Machine NIIGATA MACHINE TECHNO CO.,LTD. MD-S7000Series Specifications External Dimension Diagram(MD200S7000) Injection Unit Item Unit MD200S7000 MD310S7000 MD385S7000
More informationICP450. Compressor-cooled incubator. Product specification
Product specification Compressor-cooled incubator ICP450 Ideal for ramp operation with rapid temperature changes during incubation, breeding or storage. With the help of our model selection, with dimensioned
More informationHettCube INCUBATORS SUSTAINABLE. ERGONOMIC. HIGH QUALITY. INCUBATOR. Find out more by visiting:
HettCube S SUSTAINABLE. ERGONOMIC. HIGH QUALITY. www.hettweb.com/incubators HETTICH S GET THE MOST OUT OF YOUR S. FEATURES: Eco-friendly with low power consumption & low global warming potential (GWP)
More informationREFRIGERATOR M E D I C A L.
M E D I C A L REFRIGERATOR NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation. LRM-100 SERIES Labocon Medical Refrigerator LRM-100 Series
More informationETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT
90% EFFICIENCY HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System CLEAN AIR SINCE 1963 Euroclima is a company
More informationLaboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)
External Dimensions: B = 1500 mm D = 820 mm H = 2100 mm Inside Dimension: Room 1 B = 600 mm D = 670 mm H = 1330 mm Room 2 B = 600 mm D = 670 mm H = 1330 mm Capacity: 1500 l Temperature range: Room 1 2
More informationTemperature controllers TW, TO and TP, Speedy Therm
Temperature controllers TW, TO and TP, Speedy Therm English Compact dimensions, stainless steel tanks, internal reservoirs and couplings, high capacity peripheral pumps and electronic control board unify
More informationOperation Manual. (Version 1.5.1)
VWR symphony TM Gravity Convection General Incubator Operation Manual (Version 1.5.1) VWR symphony Gravity Convection General Incubator 414004-610, 414004-612, 414004-614, 414004-616 414004-611, 414004-613,
More information2-wire Passive Intelligent Loop (LED) Display Meter
Features Two-wire passive intelligent loop current (LED) digital meter 2-wire Passive Intelligent Loop (LED) Display Meter Embedded 2-wire Passive Programmable 4-20mA Loop (Four Digits LED) Display Meter
More informationCAREL heatersteam Electric Element Steam Humidifiers
Suggested Engineering Specifications Section 23 84 13 CAREL heatersteam Electric Element Steam Humidifiers 1. GENERAL SCOPE 1. Furnish and install as indicated on the drawings and plans, in-duct [space]
More informationProtect your research
Protect your research Advanced scientific refrigeration systems >ULT Freezers >Enzyme Freezers >Laboratory Fridges >Domestic Upright Manual Defrost Freezers >CO2 and O2 Incubators scientific pty ltd Quality
More informationSterilizer. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Sterilizer Overview. Page
Yamato Scientific America Innovating Science for Over 125 Years Sterilizer Contents Sterilizer Overview Steam Sterilization without dryer SK Series SN Series SQ Series Steam Sterilization with dryer SM
More informationPlatelet bags constant shaking for long periods of time.
Horizontal shakers for platelet bags APL-54 and APL-108 HORIZONTAL MOVEMENT AT A FIXED SPEED OF 66 R.P.M., LATERAL SHUFFLE OF 40 MM. APL-54 : CAPACITY FOR 54 PLATELET BAGS. APL-108 : CAPACITY FOR 108 PLATELET
More informationFaster Temperature (& Humidity) Chamber
Faster Temperature (& Humidity) Chamber SM series CAT.No.E17129 Stress of 5 /min. achieved with the large-capacity 1800L models. The faster 1800L temperature and humidity chamber can handle the reliability
More informationVacuum drying VD VDL series
Vacuum drying VD VDL series Extremely superior: BINDER Vacuum drying ovens u Extremely fast u Direct heat transfer to the sample material through thermal conducting plates u Fast, condensation-free drying
More informationAn ISO 9001 : 2008 Certified Company
NITROGEN TYRE AIR INFLATOR Model - FS 3500 TECHNICAL DETAILS Nitrogen purity Compressed air input range Nitrogen output N2 output pressure Nitrogen storage tank Motor power Motor voltage Weight Packing
More informationedition version 1.1 Green ICE KW Antibacteria
edition version 1.1 BlueLine K-LAB premanufactured series high-volume vertical refrigerators and freezers Green ICE KW Antibacteria K-LAB 3000 litri K-LAB 4000 litri K-LAB 5000 litri series = Min. / Max.
More informationOperation Manual (Version 1.5.1)
VWR symphony TM Low-Temp./BOD Incubator Operation Manual (Version 1.5.1) VWR symphony Low-Temp./BOD Incubator 414004-626, 414004-628, 414004-630, 414004-632 414004-627, 414004-629, 414004-631, 414004-633
More informationDOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,
DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: +971-6-5432526, Fax#: +971-6-5432415, Email: dolcool@emirates.net.ae, web site: www.dolphinheattransfer.com NOMENCLATURE: INTRODUCTION DOLCOOL branded
More informationENVIRONMENT FRIENDLY CLIMATIC CHAMBER
ZERO OZONE DEPLETION POTENTIAL ODP NEGLECTIBLE GLOBAL WARMING POTENTIAL GWP ENVIRONMENT FRIENDLY CLIMATIC CHAMBER KK-50 DFA TK-50 CKA KK-730 DFA TK-730 CKA Environment friendly solution for temperature
More informationConstant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:
Constant climate chambers KBF 240 (E5.2) - Constant climate chamber The KBF series was particularly designed for absolutely reliable stability tests and precise maintenance of constant climatic conditions.
More informationTechnical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview
Product overview 1 Company Profile Yantai Oceanair Refrigeration & Air-Conditioning Co.,Ltd. was established in 2004 and has been listed on the New OTCBB (Stock Code: 831870). We are mainly specialized
More informationReproducible Climate...
Reproducible Climate...... the new standard in test technology Temperature and Climatic Test Chambers VT 3 & VC 3 Reliable test results... Your adviser for environmental test technology... Characteristics,
More informationDigital incubating/ refrigerating benchtop shakers
I Incubators Incubated Shakers (Benchtop Models) Digital incubating/ refrigerating benchtop shakers Transparent lid offers great visibility and gas spring supports ensure hand-down handling of the samples
More informationSafety, Consistency And Reliability; Leading In The World And Recommended By China Marrow Donor Program
12 Haier Bio-Medical Haier Safety, Consistency And Reliability; Leading In The World And Recommended By China Marrow Donor Program This product is specially designed and manufactured for long time storage
More informationDehumidifying Dryers DP DP 615 Series
Dehumidifying Dryers DP 604 - DP 615 Series English The DP 604 - DP 615 Dryer Series is suitable for the treatment of hygroscopic polymers for medium productions. The design criteria of these models allows
More informationAIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW
AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW Row Cooling Precision Air Conditioner Cooling Capacity: 26.2kW~68.6kW CHILLROW is installed closely with the server cabinets and refrigerating independently. The
More information