Effect of Louvered Strips on Heat Transfer in a Concentric Pipe Heat Exchanger
|
|
- Amberly Leonard
- 6 years ago
- Views:
Transcription
1 Effect of Louvered Strips on Heat Transfer in a Concentric Pipe Heat Exchanger Somsak Pethkool 1, Smith Eiamsa-ard, Artit Ridluan and Pongjet Promvonge 1,* 1 Department of Mechanical Engineering, Faculty of Engineering, King Mongkut s Institute of Technology Ladkrabang, Bangkok 15, Thailand Department of Mechanical Engineering, Faculty of Engineering, Mahanakorn University of Technology, Bangkok 153, Thailand Abstract: Effects of the louvered strip insertion in a parallel-flow concentric double pipe heat exchanger on heat transfer performance and flow friction are experimentally investigated. The louvered narrow thin metallic strips were placed in the inner tube of the heat exchanger. Used as a turbulator and made of brass, the Louvered strips were.5 mm thick and 9 mm wide. In the system, hot water was introduced through the inner tube, while cold water was flowing through the annulus. The experimentation was performed at the ynolds number 6, to 65, and 8, for the hot and cold water flows, respectively. The inlet hot and cold water temperatures were 55 o C, and o C, respectively. The experimental results showed that the mean Nusselt number were increased up to about 46% in comparison with the plain tube, while approximately 167% of the friction factor was increased, comparative to the plain tubes. Keywords: Heat Transfer Enhancement, Heat Exchanger, Friction Factor, Louvered-strips, Louvered-turbulators 1. INTRODUCTION cently, Energy is essential for domestic industry development and it is the main problem issue not only in Thailand but also around the World. A plenty of energy problems are necessary to be urgently improved and developed. Paying the attention and efficiently economically exploiting energy are the effective way to alleviate energy problems. The heat exchange process has been involved in many engineering applications. Of production process in industrial factories and necessary, is the parameter of great interest temperature. Temperature is one of the most important factors to control production process in each section as well as the quality control of products. Therefore, the degree of temperature at various positions in production processes is significant. In this research, the processes of extracting and transferring maximum heat to intermediate working fluid were focused. Heat exchanger plays the important role in heat exchange processes and is widely used in production processes such as refrigerator and electrical power plants. Accordingly, designing the heat exchange, suitable for each application, is very significant and important and it always has the limitation of heat exchanger size and fluid flow rate. As a result of such restrictions, heat transfer rate is quite low. The enhancement of heat transfer ability to achieve high performance of heat exchangers does reduce the size of the device and the initial investment as well as the area of installation. This paper presented the method of enhancing heat exchanger performance by using the ordinary technique, passive method. The passive method can be applied by installing the turbulent circulation generator In the past, the heat transfer enhancement technique was performed in the widespread application. Those methods were, for instance, the insertion of twisted stripes and tapes [1-3], the insertion of coil wire and helical wire coil [4, 5] and the installation of turbulator [6] in the heat exchangers. The results of those studies had been shown that although heat transfer efficiencies were improved, the frictions of tube were considerably increased. The novel concept to augment heat transfer efficiency using small louvered strips was developed and investigated. The strips were arranged on the brass wire, installed inside the hot water tube. The stripes provided high turbulent and circulation flow, resulting in excellent rate of heat transfer. Figures 1 and present the installation of the louvered strip with the brass core within the copper tube. Three angles of attack of the strip investigated are 17, 6, and 31 degrees in counter clockwise direction with the core. Fig. 1 The installation of the louvered stripes inside the hot water tube Fig. Photograph of the louvered stripes Corresponding author: kppongje@kmitl.ac.th 1
2 . THEORETICAL ANALYSIS The heat exchange between hot and cold waters was used to obtain the convection heat transfer of the hot water tube. Nusselt Number, Heat transfer rate, and other related parameters of this parallel flow heat exchange were considered as follows; Heat Transfer rate of cold water c c p ( T T ) Q = M C (1) c,outlet c,inlet Heat Transfer rate of hot water h h p ( T T ) Q = M C () M h and M c are mass flow rate of hot and cold waters. C p denotes specific heat coefficient of water. (T c,outlet -T c,inlet ) and (T h,outlet -T h,inlet ) present temperature difference between inlet and outlet cold water and temperature difference of inlet and outlet hot water, respectively. An average heat transfer rate between hot and cold waters, considered in the form of convection heat transfer between copper surface and hot fluid flow, can be written as h,inlet h c Q aver = Q h,outlet Q + Q = Q (3) conv ( ) conv hh Ah cs hf = (4) The average temperature at the copper surface, appeared in equation (5), was obtained from experiment by averaging nine locations of measured temperatures at the tube surface from inlet to exit. = T (5) cs csi /ni The average temperature of hot water can be calculated from equation (6), while convection heat transfer coefficient and Nusselt number (Nu) were defined in (6) and (7) h ( T T )/ = (6) hf h,inlet + h,outlet ( T T )/A ( ) m M hc p h h,inlet h,outlet h cs hf ynolds number and friction factor were given the following relations. = (7) Num = hm D/k (8) h = ρu md/µ (9) f = m P ( ρu / )( L / D) (1) 3. EXPERIMENTAL SET-UP The apparatus and measuring devices were shown in Fig. 3. The temperature at inlet and outlet areas of hot and cold tubes inside the concentric tube heat exchanger was measured using thermocouple, whereas U-tube manometer was used to measure their pressure. Pumps were used to feed hot and cold waters to the cold and hot water tube of double pipe heat exchanger and their flow rates was measured by Rotameter. In this system, the hot and cold waters were kept and their temperatures were controlled within the hot water tank and water chiller. In experimentation, after the hot water attained and controlled at the temperature of 55 o C throughout experimental duration. The hot water was supplied to the heat exchanger. Simultaneously, the cold water, kept within water chiller, was fed to the heat exchanger. The hot and cold waters returned to storing tanks, after heat transfer between them had been operated. During the process, inlet and outlet pressures were measured using U-tube manometer. Surface temperatures of nine locations inside copper tube were measured by Thermocouple type K during of running process. All of data were collected and brought to calculate convection average heat transfer coefficient, Nusselt number and friction factor
3 Wall Temperature (Tw1...Tw9) Pressure tap Pressure tap Ts6 Ts5 Ts9 Ts8 Ts7 Ts3 Ts4 Ts Ts1 Double pipe heat exchanger Flow meter Bypass Control Cold water tank Water chiller Bypass Flow meter Control Heater Hot water tank Hot water pump Cold water pump Fig. 3 The schematic diagram of experimentation 4. EXPERIMENTAL RESULTS The experimental results were compared with the past correlation of Dittus and Boelter [7] which the correlations were formulated for smooth-surface circular tube or plain tube. Figure 4 shows the plot of Nusselt number and ynolds number from the present work and the past correlation results. The linear behavior of Nusselt number, plotted along ynolds number, was found. The trends of the present work and the past correlation are similar; however, the present work results give the lower value of Nusselt number. Figure 5 depicted the comparison for Nusselt number for the plain tube and the tube fitted with louvered turbulators. In the tube fitted with louvered turbulators, 17, 6, and 31 degrees of inclined louvered stripes were installed. The experimentation showed that 31 degrees of incidence provided the maximum Nusselt number for all ynolds number and had grown linearly. In the case of 17 and 6 degrees, Nusselt numbers were lesser than those of 31 degree, respectively. The lowest Nusselt numbers were found in plain tube over ynolds number range. The reason why the excellent heat transfer was produced by louvered fins is that the fins act as turbulator. The comparison between convection heat transfer coefficients of the plain tube and the tube fitted with louvered turbulator was shown in Figure 6. From experimental consequences, the tube fitted with louvered turbulator with 31 degree of incidence of louvered fins provided the highest convection coefficients for all ynolds number. The relationship between the coefficients and ynolds number of this case is linear. And again the minimum of convection heat transfer coefficients over ynolds number range was found in the plain tube. The tube fitted with louvered turbulators generated the high recirculation turbulent flow, disrupting the growth of the boundary layer, leading to the better heat transfer by slighting the boundary layer thickness. This physics increases convective ability of the heat transfer process from the heat exchanger surface. 3 Experimental 4 Dittus-Boelter 5 3 Nu 15 Nu Fig. 4 Verification of Nusselt number Fig. 5 Nusselt number versus ynolds number 3
4 1, ,4 1, , h (W/m o C) 6 8 Nu Nu / NuP Fig. 6 Heat transfer coefficient versus ynolds number 1. Fig. 7 Nu/Nu plain versus ynolds number Figure 7 depicted the proportion of Nusselt number of the tube with louvered turbulators to the plain tube (Nu/Nu plain ), plotted with ynolds number. It is clearly seen that the non-linear behaviors of all case are dominant. The Nusselt numbers are nonlinearly decreased as progressed. The proportion of Nusselt number of 31 degree of incidence and the plain tubes are greater than those of 17 and 6 degrees. The pressure drop characteristics of the tube with louvered turbulators and the plain tubes were presented in Figure 8. The more angle of attack of louvered fin is, the greater pressure drop is produced. The pressure drop value of the plain tube are lowest compared with the other. The pressure drop behavior is slightly nonlinear and increased as the ynolds number advance. The installed louvered fins act as fluid obstructers, causing the loss of flow kinetic energy, converted in the form of pressure drop. The experimental friction factors were compared with the past correlation of Petukhov [7] and Blasius [7]. In Fig. 9, both of the present work and past correlation of the plain tube results are harmonious. The friction factor is inversely proportional with ynolds number. Shown in Figs. 1 and 11, the friction factors become greater as the angle of attack is more and more increased. The maximum values of friction factor were found in the case 31 degrees of angle of attack, while the plain tube case gave the minimum. The friction factor has less influence, as ynolds number increase. The friction proportions of 31 degrees of incidence and the plain tubes are higher than those of 17 and 6 degrees of incidence for all ynolds number. Pressure drop (Pa) Fig. 8 Pressure drop versus ynolds number 4
5 .7 f (-) Experimental Petukhov Blasius..1. Fig. 9 Verification of friction factor f (-).6.4 f / fp Fig. 1 Friction factor versus ynolds number. Fig. 11 f/f plain versus ynolds number 5. CONCLUSIONS The research presented experimental study to improve the double pipe heat exchanger by installing the louvered strips. The results can be concluded as follows; Louvered strips enhanced heat transfer performance. The 17, 6, and 31 degrees of incidence of the strips augmented average heat transfer by approximately 133, 186, and 46 %, respectively for ynolds number range of 6 to 65 Louvered strips increased friction factors of the heat exchange device. The friction factors were increased approximately 119, 145, and 167 % by installing the inclined strips of 17, 6, and 31 degrees, respectively. 6. NOMENCLATURE Q Heat transfer rate (W) M Mass flow rate (kg/s) C p Specific heat (J/kg K) T h,inlet Hot water inlet temperature (K) T h,outlet Hot water outlet temperature (K) T c,inlet Cold water inlet temperature (K) T c,outlet Cold water outlet temperature (K) hf Cold water average temperature (K) T cs Local copper tube surface temperature (K) Average copper tube surface temperature (K) cs h m Convection heat transfer coefficient (W/m K) k Conduction heat transfer coefficient (W/mK) A h Heat transfer area (m ) D Diameter of copper tube (m) Nu m Mean Nusselt number h ynolds number P Pressure drop (Pa) f Friction factors ρ Hot water density (kg/m 3 ) U m Mean velocity (m/s) µ Fluid absolute viscosity (Ns/m ) 5
6 7. REFERENCES [1] Baker, R.C. and Charlie, B Non linear unstable systems, International Journal of Control, 3, (4), pp [] Manglik, R.M., and Bergles, A.E., 199. Heat Transfer and Pressure Drop Correlations for Twisted-Tape Inserts in isothermal Tubes: Part II-Transition and Turbulent Flows, Enhanced Heat Transfer. ASME HTD,, pp [3] Sarma, P.K., Subramanyam, T., Kishore, P.S., Dharma Rao, V., and Kakac, S., 3. Laminar convective heat transfer with twisted tape inserts in a tube. International Journal Thermal Sciences, 4, pp [4] Yakut, K., and Sahin, B., 4. The effects of vortex characteristics on performance of coiled wire turbulators used for heat transfer augmentation. Applied Thermal Engineering Journal, 4 (16), pp [5] Sethumadhavan, R., and Rao, M.R., Turbulent Flow Heat Transfer and Fluid Friction in Helical-Wire-Coil-Inserted Tubes. International Journal of Heat and Mass Transfer, 6 (1), pp [6] Yilmaz, M., Comakli, O., and Yapici, S., Enhancement of heat transfer by turbulent decaying swirl flow. Energy Conversion Management An International Journal, 4, pp [7] Incropera, F. and DeWitt, D. Introduction to Heat Transfer, 4 th edition. John Wiley & Sons, New York,. 6
Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts
International Journal of Current Engineering and Technology E-ISSN 2277 416, P-ISSN 2347 5161 216 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Experimental
More informationijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12
EXPERIMENTAL ANALYSIS OF THE EFFECT OF FIN GEOMETRY ON HEAT TRANSFER RATE THROUGH THE REFRIGERATOR CONDENSER ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12
More informationExperimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack
Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack #1 Digvijay A. Shelar, #2 N.S. Gohel, #3 R. S. Jha #1 Mechanical Engineering Department,
More informationExperimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a)
International OPEN ACCESS Journal Of Modern Engineering Research (IJMER) Experimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a) Monika Tiwari 1, Dr.
More information[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785
IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY PERFORMANCE ANALYSIS OF VCR SYSTEM WITH VARYING THE DIAMETERS OF HELICAL CONDENSER COIL BY USING R-134A REFRIGERANT R.Hussain
More informationIMPROVE THE EFFICIENCY OF HEAT EXCHANGER IN OIL COOLER.
IMPROVE THE EFFICIENCY OF HEAT EXCHANGER IN OIL COOLER. PARMAR NAVIN J (D11ME09) PRAJAPATI JAIMIN R (10ME41) PATEL DEEP K (10ME56) INTERNAL GUIDE:- DIXIT M PATEL ABSTRACT For shell-and-tube oil cooler
More informationDesign, Development & Testing of Double Pipe Heat Exchanger With Heat Transfer Enhancement Liners
Volume 2, Issue 1, January 2017 ISSN (online): 2456-0006 International Journal of Science Technology Management and Research Available online at: Design, Development & Testing of Double Pipe Heat Exchanger
More informationThermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System
Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System A D Parekh, and P R Tailor Abstract Because of damaging effect of CFC refrigerants on stratospheric
More informationIn the name of God. Jami Institute of Jami - Mehdi Rasti
In the name of God 1 Heat Transfer Jami Institute of Technology Heat Exchangers part 2 Mehdi Rasti 2 The Counter-Flow Heat Exchanger In contrast to the parallel-flow exchanger, this configuration provides
More informationInternational Journal of Engineering Research & Technology (IJERT) ISSN: Vol. 2 Issue 10, October
Thermodynamic and Hydrodynamic Performance of Double Pipe Heat Exchanger with Bended Strips Prof. S. S. Rajigare, Prof. H. M. Dange Assistant professor at KJCOEMR Pune, Professor PVPIT Sangli Abstract
More information2. HEAT EXCHANGERS MESA
1. INTRODUCTION Multiport minichannel and microchannel aluminium tubes are becoming more popular as components in heat exchangers. These heat exchangers are used in various industrial applications and
More informationHEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1
HEFAT27 5 th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp PERFORMANCE ANALYSIS OF AIR-COOLED CONDENSER USING MICRO-FIN TUBES P.A.Patil
More informationGlobal Journal of Engineering Science and Research Management
EXPERIMENTAL AND THEORETICAL STUDY OF MINIATURE VAPOR COMPRESSION CYCLE USING MICROCHANNEL CONDENSER Issam M. Ali Aljubury*, Ahmed Q. Mohammed, Marwa S. Neama * Mechanical Eng. Dept. College of Engineering,
More informationA REVIEW ON HEAT TRANSFER ENHANCEMENT BY PASSIVE METHODS
A REVIEW ON HEAT TRANSFER ENHANCEMENT BY PASSIVE METHODS Mr. Tejas Sonawane 1, Mr. Prafulla Patil 1, Mr. Abhay Chavhan 1, Prof. B.M.Dusane 2 1UG Student, Department of Mechanical Engineering, 2Assistant
More informationENSC 388: Engineering Thermodynamics and Heat Transfer
ENSC 388: Engineering Thermodynamics and Heat Transfer Experiment 3: Free and Forced Convection Objective Determination of heat transfer coefficient for free and forced convection for different geometries.
More informationANALYSING THE EFFECTIVENESS OF THE HEAT EXCHANGER BY INCREASING OVERALL HEAT TRANSFER COEFFICIENT
ANALYSING THE EFFECTIVENESS OF THE HEAT EXCHANGER BY INCREASING OVERALL HEAT TRANSFER COEFFICIENT Mazhar Mumbaiwala 1, Rahul Panjwani 2, Rishikesh Shulav 3, Shashwat Budholia 4, Anshu Kumar 5 1,2,3,4UG
More informationEffects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 1998 Effects of Frost Formation on the External Heat Transfer Coefficient of
More informationThermal Analysis of Concentric Tube Heat Exchanger Using Louvered Strip Inserts
Thermal Analysis of Concentric Tube Heat Exchanger Using Louvered Strip Inserts Anoop P S 1, N. Sreenivasalu Reddy 2 1 PG scholar, Raja Rajarajeswari College of Engineering, Bangalore-560074, Karnataka,
More informationFalling Film Heat Exchangers for Solar Water Heaters
Y.C., G.L. Morrison and M. Behnia School of Mechanical and Manufacturing Engineering University of New South Wales Sydney 2052 AUSTRALIA E-mail: yens@student.unsw.edu.au Abstract The characteristics of
More information[Jhansi, 5(10): October 2018] ISSN DOI /zenodo Impact Factor
GLOBAL JOURNAL OF ENGINEERING SCIENCE AND RESEARCHES PERFORMANCE ANALYSIS OF VCR SYSTEM WITH TWISTED TAPE CONDENSER BY USING R134a REFRIGERANT Chidige Jhansi* 1 & Dr.Smt.G.Prasanthi 2 *1 PG Research Scholar
More informationSolar air heater duct having triangular protrusions As roughness elements on absorber plate
Solar air heater duct having triangular protrusions As roughness elements on absorber plate A. Nagaraju 1, B. Chnadramohan Reddy 2 1,2 Department of Mechanical Engineering, Jawaharlal Nehru Technological
More informationExperimental analysis of condensation heat transfer enhancement of steam at low pressures using modified twisted tape insert
International Journal of Current Engineering and Technology E-ISSN 2277 4106, P-ISSN 2347 5161 2016 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Experimental
More informationHeat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling
Enhancement using Herringbone wavy & Smooth Wavy fin Exchanger for Hydraulic Oil Cooling 1 Mr. Ketan C. Prasadi, 2 Prof. A.M. Patil 1 M.E. Student, P.V.P.I.T.,Budhagaon,Sangli AP-India 2 Associate Professor,
More informationPerformance Study of Triple Concentric Pipe Heat Exchanger
Performance Study of Triple Concentric Pipe Heat Exchanger #1 Pravin M. Linge, #2 A. B. Korane, #3 V. N. Kapatkar #123 Mechanical Engineering Department, Sinhgad College of Engineering, SPPU, Pune, India
More informationThermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater
Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater Gurpreet Singh and Satwant Singh Lala Lajpat Rai Institute of Engineering and Technology, Moga (Punjab) 142001 Abstract : Artificial
More informationEnhancement of COP in Vapour Compression Refrigeration System
Enhancement of COP in Vapour Compression Refrigeration System M. Krishna Prasanna #1 M.E student, Heat Transfer studies in Energy Systems Department of Mechanical Engg., Andhra University Visakhapatnam-530003,
More informationExperimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers
Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers Ashraf A 1, Mohammed Shan N 2, Thoufeeq Azad 3, Bibin S4, Arun S 5 1-4 Students, 5 Assistant Professor Department of
More information1, 2
HEAT TRANSFER ENHANCEMENT BY SWIRL FLOW DEVICES Tarique Anwar Qureshi 1, Anil Singh Yadav 2 1 Assistant Professor, Technocrats Institute of Technology and Science (TITS), Bhopal (M.P) 2 Professor, Lakshmi
More informationDesign and Development of Water Cooled Condenser for Domestic Refrigerator
Design and Development of Water Cooled Condenser for Domestic Refrigerator Anil S. Patil Research PG Student, GF s Godavari College of Engineering, Jalgaon Dr. Atul A Patil Assot. Prof. GF s Godavari College
More informationPressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C
drop analysis of evaporator using refrigerants R-22, R-404A and R-407C #1 Pallavi Sawkar, #2 Dr. Pradeep Patil #12 Department of Mechanical Engineering, JSPM s JSCOE, Savitribai Phule Pune University,
More informationPerformance Analysis of a Thin Tube Water Heater for Egerton University Using Comsol
Performance Analysis of a Thin Tube Water Heater for Egerton University Using Comsol Dr. Owino, George Omollo 1, Isiah Otieno Onditi 2, Lecturer, Department of Industrial and Energy Engineering, Egerton
More informationSeyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2
Modern Applied Science; Vol. 9, No. 13; 2015 ISSN 1913-1844 E-ISSN 1913-1852 Published by Canadian Center of Science and Education The Design of a Shell-Tube Heat Exchanger as Evaporator an Absorption
More informationEffects of mass flow rate in terms of pressure drop and heat transfer characteristics
Merit Research Journal of Environmental Science and Toxicology Vol. 1(1) pp. 005-011, March, 2013 Available online http://www.meritresearchjournals.org/est/index.htm Copyright 2013 Merit Research Journals
More informationTHE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE
Proceedings of the Asian Conference on Thermal Sciences 2017, 1st ACTS March 26-30, 2017, Jeju Island, Korea ACTS-P00385 THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK
More informationINFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS
INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS Staņislavs GENDELIS, Andris JAKOVIČS Laboratory for mathematical modelling of environmental
More informationFROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE
HEFAT2012 9 th International nference on Heat Transfer, Fluid Mechanics and Thermodynamics 16 18 July 2012 Malta FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE Kim K.,
More informationHeat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a
2011 International Conference on Advanced Materials Engineering IPCSIT vol.15 (2011) (2011) IACSIT Press, Singapore Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a Eed Abdel-Hafez
More informationGandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]
Experiment 1 Study of fundamentals of Fluid Flow and Heat Transfer associated with Heat Exchangers Review questions (1) Significance of dimensionless numbers. (2) Define overall heat transfer coefficient.
More informationHot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump
Available online at www.sciencedirect.com Procedia Engineering 8 (2011) 165 170 2 nd International Science, Social-Science, Engineering and Energy Conference 2010: Engineering Science and Management Hot
More informationExperimental Studies on Aero Profile Thermosyphon Solar Water Heating System
International Journal of Engineering Research and Technology. ISSN 0974-3154 Volume 9, Number 1 (2016), pp. 89-94 International Research Publication House http://www.irphouse.com Experimental Studies on
More informationRaman et al., International Journal of Advanced Engineering Technology E-ISSN
Research Paper EFFECT OF ELLIPTICAL INCLINED DIMPLES ON NUSSELT NUMBER AND FRICTION FACTOR FOR ARTIFICIALLY ROUGHENED DUCT OF SOLAR AIR HEATERS Raman Kumar a, Harvinder Lal b Address for Correspondence
More informationPerformance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger
Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger Abstract Shoeb J. Inamdar 1 H.S. Farkade 2 M. Tech student. (Thermal Engineering) 1, Asst. Professor 2 Department of Mechanical
More informationTheoritical Analysis For Miniature Vapor Compression Cycle Performance Using Microchannel And Finned Tube Condenser
Theoritical Analysis For Miniature Vapor Compression Cycle Performance Using Microchannel And Finned Tube Condenser Issam Mohammed Ali Ahmed Qasim Mohammed Marwa Sallah Neama Mechanical Eng. Dept Air-
More informationA STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS
A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS V. BHOGESWARA RAO Research Scholar Email:pallivayala@gmail.com Dr. S. CHAKRADHAR GOUD Principal, Sri Sarada Institute of Science and Technology
More informationTHERMOHYDRAULIC PERFORMANCE OF AN EQUILATERAL TRIANGULAR DUCT WITH ARTIFICIAL ROUGHNESS USED IN SOLAR AIR HEATER
THERMOHYDRAULIC PERFORMANCE OF AN EQUILATERAL TRIANGULAR DUCT WITH ARTIFICIAL ROUGHNESS USED IN SOLAR AIR HEATER GAURAV BHARADWAJ 1, VARUN 2 & AVDHESH SHARMA 3 1,2&3 Mechanical Engineering dept. National
More informationA Review on Comparative Study of Thermal Performance of Artificially Roughened Solar Air Heaters
A Review on Comparative Study of Thermal Performance of Artificially Roughened Solar Air Heaters Ashwini Kumar 1, Mahmood Alam 2 1 Mechanical Engineering Department, N.I.T., Jamshedpur, India-831014 2
More informationSpecific Energy Consumption comparative study of Hot Air dryer and Heat Pump dryer for highland drying process Sayompon Srina
Specific Energy Consumption comparative study of Hot Air dryer and Heat Pump dryer for highland drying process Sayompon Srina Department of Mechanical Engineering, Faculty of Engineering, King Mongkut
More informationInduction heating with the ring effect for injection molding plates
Induction heating with the ring effect for injection molding plates article info abstract Available online 8 March 2012 Keywords: Dynamic mold temperature control Induction heating Inductor design Induction
More informationA study on performance improvement of corrugated type total heat exchanger considering the structure of flow passage on surface
Journal of Mechanical Science and Technology 23 (2009) 528~535 Journal of Mechanical Science and Technology www.springerlink.com/content/738-494x DOI 0.007/s2206-009-0426-0 A study on performance improvement
More informationPerformance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION
2597, Page 1 Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump Ian H. BELL 1 *, James E. BRAUN 2 1 Bell Thermal Consultants ian.h.bell@gmail.com 2 Purdue
More informationExperimental Investigation of Tube Configuration for a Surface Condenser
Experimental Investigation of Tube Configuration for a Surface Condenser Shrikant Subhash Chaudhari 1, T Mahender 2, Subramanyam Pavuluri 3 PG Student, Department of Mechanical Engineering, MLR Institute
More informationStudy of air circulation inside the oven by computational fluid dynamics.
The 8 th International TIChE Conference (ITIChE 2018) "Designing Tomorrow Towards Sustainable Engineering and Technology" @A-ONE The Royal Cruise Hotel Pattaya, Thailand, November 8-9, 2018 Study of air
More informationVariable far infrared radiation (VFIR) technique for cubic carrot drying
International Journal of Renewable Energy, Vol. 7, No. 2, July - December 2012 Variable far infrared radiation (VFIR) technique for cubic carrot drying Sirinuch Chindaruksa a *, Pisit Maneechot b, Seishu
More informationa Heat Exchanger using FEA Tool
A Review on Optimal Design of Single Tube in a Heat Exchanger using FEA Tool Roshan V. Marode Abstract:- The performance of heat exchangers can be improved to perform a certain heat-transfer duty by heat
More informationEFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES
International Journal of Mechanical and Materials Engineering (IJMME), Vol. 2 (2007), No. 2, 109--117. EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES M. Hasanuzzaman
More informationINTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY
INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY A PATH FOR HORIZING YOUR INNOVATIVE WORK SPECIAL ISSUE FOR NATIONAL LEVEL CONFERENCE "RENEWABLE ENERGY RESOURCES & IT S
More informationNatural Convection Heat Transfer Augmentation from Heat Sinks using Perforated Fins: A Review
(JMSME) Print ISSN : 2339-9095; Online ISSN : 2393-9109; Volume 2, Number 6; April June, 2015 pp 80 84 Krishi Sanskriti Publications http://www.krishisanskriti.org/jmsme.html Natural Convection Heat Transfer
More informationExperimental Comparison of Natural Convection Heat Transfer from a Blackened V-Fin Array
International Journal of Modern Studies in Mechanical Engineering (IJMSME) Volume 4, Issue 1, 2018, PP 11-16 ISSN 2454-9711 (Online) DOI: http://dx.doi.org/10.20431/2454-9711.0401002 www.arcjournals.org
More informationPerformance Analysis Of Double Inclination Ribbed Solar Air Heater Rectangular Duct By Liquid Crystal Thermography
Performance Analysis Of Double Inclination Ribbed Solar Air Heater Rectangular Duct By Liquid Crystal Thermography Amit Kumar Gautam¹, Dr. J. L. Bhagoria² ¹M.Tech. Scholar, Mechanical Engineering, ²Professor,
More informationINTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY
INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY A PATH FOR HORIZING YOUR INNOVATIVE WORK EXPERIMENTAL INVESTIGATION OF HELICAL COIL AND STRAIGHT TUBE HEAT EXCHANGER 1.
More informationScientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University
Scientific Principals and Analytical Model Charcoal Cooler Lisa Crofoot MECH 425, Queens University 1.0 Scientific Principles Evaporative cooling is based on the principle that water requires heat energy
More informationTHERMAL ENGINEERING LABORATORY II. To train the students with principles and operation of thermal Engineering equipments.
AIM: THERMAL ENGINEERING LABORATORY II To train the students with principles and operation of thermal Engineering equipments. OBJECTIVES: To experimentally analyze conduction, convection and radiation.
More informationDrying Parawood with Superheated Steam
American Journal of Applied Sciences 4 (4): 215-219, 2007 ISSN 1546-9239 2007 Science Publications Drying Parawood with Superheated Steam Surachai Bovornsethanan and Somchai Wongwises Department of Mechanical
More informationCompression of Fins pipe and simple Heat pipe Using CFD
Compression of Fins pipe and simple Heat pipe Using CFD 1. Prof.Bhoodev Mudgal 2. Prof. Gaurav Bhadoriya (e-mail-devmudgal.mudgal@gmail.com) ABSTRACT The aim of this paper is to identify the advantages
More informationCFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5
IJAET International Journal of Application of Engineering and Technology ISSN: 2395-3594 Vol-1 No.-2 CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys
More informationAssistant Professor),( Professor), Department of Mechanical Engg., B.I.T. Sindri 3. Professor, Department of Mechanical Engg., N.I.T.
Experimental study of Collector heat removal factor and Collector efficiency factor of flat-plate solar Air Heater having roughened (Rhombus shape) absorber plate 1 Pankaj Kumar, 2 Dr. S.C.Roy, 3 Dr.M.K.Paswan
More informationEFFECT OF DIVERSE STREAM PATTERNS ON THE PERFORMANCE OF SOLAR AIR HEATER
Int. J. Mech. Eng. & Rob. Res. 2013 P Velmurugan and R Kalaivanan, 2013 Research Paper ISSN 2278 0149 www.ijmerr.com Vol. 2, No. 1, January 2013 2013 IJMERR. All Rights Reserved EFFECT OF DIVERSE STREAM
More informationInternal flow Patterns of the Horizontal Heat Mode Closed-Loop Oscillating Heat Pipe with Check Valves (HHMCLOHP/CV)
Research Journal of Applied Sciences, Engineering and Technology 5(3): 865-869, 2013 ISSN: 2040-7459; E-ISSN: 2040-7467 Maxwell Scientific Organization, 2013 Submitted: June 13, 2012 Accepted: July 09,
More informationAmerican International Journal of Research in Science, Technology, Engineering & Mathematics
American International Journal of Research in Science, Technology, Engineering & Mathematics Available online at http://www.iasir.net ISSN (Print): 2328-3491, ISSN (Online): 2328-358, ISSN (CD-ROM): 2328-3629
More informationPROCEEDINGS SOLAR 95
PROCEEDINGS OF SOLAR 95 THE 1995 AMERICAN SOLAR ENERGY SOCIETY ANNUAL CONFERENCE Minneapolis, Minnesota July 15-20,1995 Editors: R. Campbell-Howe B. Wilkins-Crowder American Solar Energy Society 2400 Central
More informationDesign Based Comparative Study of Several Condensers Komal B. Dabhi 1, Prof. S. B. Thakore 2 1 Chemical Engg. Dept., L. D. College of Engineering, Ahmedabad 380015 2 Chemical Engg. Dept., L. D. College
More informationTHERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE
THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE Pushpendra Singh 1, Vipin Shrivastava 2 1,2 Mechanical Engineering Department, Lakshmi Narain College of Technology (India) ABSTRACT
More informationEnhancement of Round Tube and Flat Tube- Louver Fin Heat Exchanger Performance Using Deluge Water Cooling
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2012 Enhancement of Round Tube and Flat Tube- Louver Fin Heat Exchanger Performance
More informationPREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE
PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING M. POIRIER, D. GIGUÈRE, Z. AIDOUN, M. OUZZANE Natural Resources Canada, CANMET Energy Technology Centre-Varennes 1615, Lionel
More informationCHAPTER 3 EXPERIMENTAL SETUP AND PROCEDURE
31 CHAPTER 3 EXPERIMENTAL SETUP AND PROCEDURE 3.1 DETAILS OF EXPERIMENTAL FACILITY The schematic diagram and photographic view of the experimental setup are shown in Figures 3.1 and 3.2 respectively. Experimental
More informationJurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015
The Design of a Heat Exchanger Shell - Tube as Evaporator an Absorption Chiller Cycle to Reduce the Temperature of the Air Entering Diesel Engine Heavy Loads 75% And 50% of the Engine Part Seyyede Sepideh
More informationPerformance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger
Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger Shoeb Inamdar 1, H. S. Farkade 2 P.G. Student, Department of Mechanical Engineering, Govt. College of Engg. Amravati. Maharashtra,
More informationMeasurement of internal pressure and thermal performance in a closed-loop oscillating heat-pipe with check valves (CLOHP/CV)
Indian Journal of Pure & Applied Physics Vol. 52, August 2014, pp. 531-540 Measurement of internal pressure and thermal performance in a closed-loop oscillating heat-pipe with check valves (CLOHP/CV) S
More informationEFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM
- 1 - EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM Shun YOSHIOKA, Hyunyoung KIM, Kazushige KASAI, Daikin Industries,
More informationEFFECT OF WATER RADIATOR ON AIR HEATING SOLAR COLLECTOR EFFICIENCY
EFFECT OF WATER RADIATOR ON AIR HEATING SOLAR COLLECTOR EFFICIENCY Aivars Aboltins, Janis Palabinskis Latvia University of Agriculture aivars.aboltins@inbox.lv Abstract. The paper describes the results
More informationHeat Transfer Enhancement in Shell and Tube Condenser
International Journal of Current Engineering and Technology E-ISSN 2277 4106, P-ISSN 2347 5161 2017 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Heat
More informationNumerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger
International Journal of ChemTech Research CODEN( USA) IJCRGG ISSN 0974-4290 Vol.5, No.2, pp 925-934, April-June 2013 ICGSEE-2013[14th 16th March 2013] International Conference on Global Scenario in Environment
More informationCHAPTER 7 COMPARISON OF HEAT EXCHANGERS
168 CHAPTER 7 COMPARISON OF HEAT EXCHANGERS Heat exchangers may be classified according to their flow arrangement. In parallel flow heat exchangers, the two fluids enter the exchanger at the same end,
More informationFeasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System
Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System Kwanghee Seo 1) and Taewan Kim 2)* 1) KEPCO Engineering & Construction Company. INC., 269 Hyeoksin-ro,
More informationExperimental Analysis of a Stirling Refrigerator Employing Jet-Impingement Heat Exchanger and Nanofluids
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2010 Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement
More informationII. OBJECTIVE OF RESEARCH
Enhancement of Coefficient of Performance of Vapor Compression Refrigeration System Using Diffuser at let of Condenser Mr. Nurul Seraj 1, Dr. S. C. Roy 2 1 Student, 2 Head of Department, Department of
More informationNATURAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING SYSTEMS. Technical Progress Report April 1,1995 to May 31,1995
NATURAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING SYSTEMS Technical Progress Report April,995 to May 3,995 Jane H. Davidson Department of Mechanical Engineering University of Minnesota Minneapolis,
More informationEXPERIMENT NO. III AIR ENTRAINMENT INTO AN IRS DEVICE
Objective EXPERIMENT NO. III AIR ENTRAINMENT INTO AN IRS DEVICE To investigate air entrainment into a louvered infrared suppression (IRS) device experimentally on a laboratory scale set up both with cold
More informationTITLE: Improvement in Heat Transfer Rate and Dynamics of Shrouded Fanned Radiator System
TITLE: Improvement in Heat Transfer Rate and Dynamics of Shrouded Fanned Radiator System Prof. G.L.Allampallewar 1, Divyal P. Bagul 2, Abhiraj S. Galande 3, Amol M. Rathod 4, Ketan R. Behere 5. 1 Assistant
More informationExperimentation of Heat Pipe Used In Nano-Fluids
Experimentation of Heat Pipe Used In Nano-Fluids 1 Prashant Shinde, 2 Vinod Shinde, 3 Rajiv Talape, 4 D.N. Korade 1,2,3,4 Department of Mechanical Engineering, Sinhgad Institute of Technology & Science,
More information0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe
Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe Brig Gen Md. Lutfor Rahman, Sumaiya Nawrin, Rasel A Sultan Department of Mechanical Engineering, Military Institute
More informationJülich Solar Power Tower System Behavior During Downtime
Jülich Solar Power Tower System Behavior During Downtime Torsten Baumann 1, a), Felix Göhring 1, b), Hannes Stadler 1,c) and Till Doerbeck 2,d) 1 German Aerospace Center (DLR), Institute of Solar Research,
More informationDesign and analysis of household direct cool refrigerator with vertical evaporator
Design and analysis of household direct cool refrigerator with vertical evaporator #1 Ashish Devidas Matkar, #2 R.D.Shelke, #3 H.N.Deshpande #123 Mechanical Engineering Heat Power, PES Modern College of
More informationPERFORMANCE ENHANCEMENT OF AIR CONDITIONER *
PERFORMANCE ENHANCEMENT OF AIR CONDITIONER * K. B. Vijay, E. Naresh Kumar, T.Parameshwaran Pillai 1 Dept. of Mechanical Engineering. Anna University Chennai (BIT Campus), Tiruchirappalli 24 *corresponding
More informationModule 5: Combustion Technology. Lecture 38: Combustion Burners
1 P age Module 5: Combustion Technology Lecture 38: Combustion Burners 2 P age Keywords : Atmospheric burner, atomizer, rotating cup burner, swirl type burner, nozzle design 5.7 Combustion Burners Types
More informationEXPERIMENTAL PERFORMANCE INVESTIGATION OF SWIRLING FLOW ENHANCEMENT ON FLUIDIZED BED DRYER
EXPERIMENTAL PERFORMANCE INVESTIGATION OF SWIRLING FLOW ENHANCEMENT ON FLUIDIZED BED DRYER P. Sundaram and P. Sudhakar Department of Mechanical Engineering, SRM University, Kattankulathur, Chennai, India
More informationKeywords: Triple tube heat exchanger (TTHE), hot water, cold water, CFD simulation.
International Engineering Research Journal Design and CFD analysis of concentric triple tube heat exchanger with circular fins Girishkumar Patil, Prof.S.K.Bhosale and Prof.V.S.Shinde ϯ ϯ Abstract The triple
More informationFUNDAMENTAL BASIS AND IMPLEMENTATION OF SHELL AND TUBE HEAT EXCHANGER PROJECT DESIGN: EVAPORATOR STUDY
FUNDAMENTAL BASIS AND IMPLEMENTATION OF SHELL AND TUBE HEAT EXCHANGER PROJECT DESIGN: EVAPORATOR STUDY A.S. Dalkilic O. Acikgoz S. Tapan S. Wongwises Heat and Heat and Thermodynamics Thermodynamics Division,
More informationPerformance Enhancement of Inclined Bubbling Fluidized Bed Paddy Dryer by Design Modification
Performance Enhancement of Inclined Bubbling Fluidized Bed Paddy Dryer by Design Modification Phyu Phyu Thant, P. Mahanta, P.S. Robi Abstract Present paper discusses the bed inclination and passive inserts
More informationSant Gadge Baba Amravati University. Amravati, Maharashtra, India, Maharashtra 2
2018 IJSRST Volume 4 Issue 8 Print ISSN: 2395-6011 Online ISSN: 2395-602X Themed Section: Science and Technology Heat Transfer Characteristic of Spiral Heat Exchanger: Effect of Reynolds Number on Heat
More information