Green Refrigerant. MULTI-TEC WALL-MOUNT Features All Models. Standard Features All Models

Size: px
Start display at page:

Download "Green Refrigerant. MULTI-TEC WALL-MOUNT Features All Models. Standard Features All Models"

Transcription

1 The MULTI-TEC Wall-Mount Air Conditioner utilizes PLC (Programmable Logic Control) technology to allow multiple units to operate connected to a single LC00 controller. When installed with an optional 0% free cooling economizer, the unit will supply full-rated airflow in free cooling mode with the ability to exhaust unconditioned indoor air without the need for additional relief openings in the structure. tandard Features All Models THE MULTI-TEC WALL-MOUNT AIR CONDITIONER EER ( HZ) WITH LOGIC BOARD WAAP to W72ABP Right-ide Control Panel WLAP to W72LBP Left-ide Control Panel. to Ton (7,000 to 7,000 Btuh) MULTI-TEC WALL-MOUNT Features All Models Programmable Logic Board: Unit control panels are equipped with progammable logic boards that allow multiple unit operation with a single controller. Unit connection to the LC controller is accomplished via 2 wire with drain (ground). Dirty Filter witch: Field adjustable with alarm signal. Advanced Unit Diagnostics: When connected to the TEC-EYE TM diagnostic tool, the unit PLC logic board is able to display stored alarms and easy-to-read diagnostic information. The TEC-EYE TM also displays unit model and serial number. Remote Monitoring: Bard-Link web interface with use of LC Controller. Free Cooling Unit: Full flow free cooling unit economizer with positive shutoff sealing as optional equipment. Proper operation is verified through alarm notifications. NOTE: All of the above Features are unique to the MULTI-TEC. Green Refrigerant R-4A Copper Tube / Aluminum Fin s: Grooved copper tubing and enhanced aluminum fins provide maximum heat transfer and high energy efficiency. Optional phenolic-coated coils are also available. Twin Blowers: Move air quietly with standard dual blower configuration on slide tracks for service. R-4A Refrigerant: Designed with R-4A (HFC) non-ozone depleting refrigerant in compliance with the Montreal protocol and EPA requirements. Galvanized Gauge Zinc Coated teel Cabinet: Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on textured enamel, which allows it to withstand 00 hours of salt spray tests per ATM B7-03. Condenser section and entire cabinet coatings are also available. Foil Faced Insulation: tandard on all units. A/C Unit Controls: All unit controls rated at -C/-F. Full Length Mounting Brackets: Built into cabinet for improved appearance and easy installation. NOTE: Bottom mounting bracket included to assist in installation. Liquid Line Filter Drier: tandard on all units. Protects system against moisture. Compressor Control Module: tandard on all units. Built-in offdelay timer adjustable from seconds to minutes. 2-minute on-delay if power interrupt. -second bypass for low pressure control, and both soft and manual lockouts for high and low pressure controls. Alarm output for alarm relay. Electrical Components: Are easily accessible for routine inspection and maintenance through side service panel opening. Features a lockable, hinged access cover to the circuit breaker. 24V Transformer: 0VA with circuit breaker Electric Heat trips: Features an automatic limit and thermal cut-off safety control. Heater packages are factory installed. One-Inch, MERV 2 Air Filters: Are standard equipment. All models include tight-sealing U-channel filter bracket to minimize air bypass around the filter. Condenser Fan and Motor hroud Assembly: lides out for easy access. Built-In Circuit Breakers: HACR-type circuit breakers are standard for AC power supply. lope Top: tandard feature for water run-off. Top Rain Flashing: tandard feature on all models. High & Low Pressure witches are Auto-Reset: tandard on all units. Built-in lockout circuit resets from the Bard-Link Controller. Provides commercial quality protection to the compressor. Low Ambient Control: Fan cycling LAC standard on all models. crew-on fitting design for ease of service. Evaporator Freeze Protection: tandard on all units. Phase Rotation Monitor (3-Phase Units Only): Protects against reverse rotation if AC power supply is not properly connected. MULTI-TEC WALL-MOUNT Unit LC00 Controller Certified to ANI/ARI tandard for PVU (ingle Package Vertical Units). Complies with efficiency requirements of AHRAE/IENA Intertek ETL Listed to tandard for afety Heating and Cooling Equipment ANI/UL /CA 22.2 No. 23-0, Fourth Edition. Commercial Product - Not intended for Residential application. Bard is an IO 00:0 Certified Manufacturer Form No upersedes 32-7 Page of

2 Capacity and Efficiency Ratings Models WAAP WLAP W24AAP W24LAP WAAP WLAP W3AAP W3LAP Capacity is certified in accordance with ANI/ARI tandard EER = Energy Efficiency Ratio and is certified in accordance with ANI/ARI tandard All ratings based on fresh air intake being 0% closed (no outside air introduction). W42AAP W42LAP W4AAP W4LAP WAAP WLAP W72ABP W72LBP Cooling Capacity BTUH 7,000 24,0,000 3,0 4,0 4,000,000 7,000 EER pecifications -/2 Ton through 3 Ton MODEL WAAPA WLAPA W24AAPA W24LAPA W24AAPB W24LAPB W24AAPC W24LAPC WAAPA WLAPA WAAPB WLAPB WAAPC WLAPC W3AAPA W3LAPA W3AAPB W3LAPB W3AAPC W3LAPC Electrical Rating Hz 2/- 2/- 2/ /- 2/ /- 2/ Operating Voltage Range Compressor--Circuit A Voltage 2/ 2/ 2/ 4 2/ 2/ 4 2/ 2/ 4 Rated Load Amps.0/..2/..0/. 4.3./2.0./ /./.. Branch Circuit election Current Lock Rotor Amps 4/4 4/4 / 2 77/77 7/7 3 2/2 / 44 Compressor Type croll croll croll croll croll croll croll croll croll croll Fan Motor & Condenser Fan Motor--HP--RPM / - 7 / - 7 / - 7 / - 7 / - 7 / - 7 / - 7 / - 7 / - 7 / - 7 Fan Motor--Amps Fan--DIA/CFM " - 00 " - 00 " - 00 " - 00 " - 20 " - 20 " - 20 " - 20 " - 20 " - 20 Blower Motor & Evap. Blower Motor--HP-RPM-PD /-0-2 /-0- /-0- /-0- /3-0-2 /3-0-2 /3-0-2 /3-0-2 /3-0-2 /3-0-2 Blower Motor--Amps Motor Type PC PC PC PC PC PC PC PC PC PC CFM Cooling & E..P. w/filter (Rated- ) Filter izes (inches) TD. xx xx xx xx xx xx xx xx xx xx Basic Unit Weight-LB Blank-Off Plate Economizer hipping Weight-LB Form No upersedes 32-7 Page 2 of

3 pecifications 3-/2 Ton through Ton MODEL W42AAPA W42LAPA W42AAPB W42LAPB W42AAPC W42LAPC W4AAPA W4LAPA W4AAPB W4LAPB W4AAPC W4LAPC W4AAPQ W4LAPQ Electrical Rating Hz 2/- 2/ /- 2/ Operating Voltage Range Compressor--Circuit A Voltage 2/ 2/ 4 2/ 2/ 4 7 Rated Load Amps./..4/ /../3.3.. Branch Circuit election Current Lock Rotor Amps / 3./3. 4 / / 4 Compressor Type croll croll croll croll croll croll croll Fan Motor & Condenser Fan Motor--HP--RPM-PD /3--2 /3--2 /3-- /3--2 /3--2 /3-- /3--2 Fan Motor--Amps Fan--DIA/CFM 24" " " " " " "-00 Blower Motor & Evap. Blower Motor--HP-RPM-PD /3--2 /3--2 /3--2 /3--2 /3--2 /3--2 /3--2 Blower Motor--Amps Motor Type PC PC PC PC PC PC PC CFM Cooling & E..P. w/filter (Rated- ) Filter izes (inches) TD. xx xx xx xx xx xx xx Basic Unit Weight-LB Blank-Off Plate Economizer hipping Weight-LB MODEL WAAPA WLAPA WAAPB WLAPB WAAPC WLAPC WAAPQ WLAPQ W72ABPA W72LBPA W72ABPB W72LBPB W72ABPC W72LBPC W72ABPQ W72LBPQ Electrical Rating Hz 2/- 2/ /- 2/ Operating Voltage Range Compressor--Circuit A Voltage 2/ 2/ 4 7 2/ 2/ 4 7 Rated Load Amps 2./ / /.4./ Branch Circuit election Current Lock Rotor Amps / / 43 / 4/4 7 4 Compressor Type Recip. Recip. Recip. Recip. croll croll croll croll Fan Motor & Condenser Fan Motor--HP--RPM-PD /3--2 /3--2 /3-- /3-- /2-7- /2-7- 3/4-7- 3/4-7- Fan Motor--Amps Fan--DIA/CFM 24" - 24" - 24" " " " "-00 Blower Motor & Evap. Blower Motor--HP-RPM-PD / / / / /4--2 3/4--2 3/4--2 3/4--2 Blower Motor--Amps Motor Type PC PC PC PC ECM ECM ECM ECM CFM Cooling & E..P. w/filter (Rated- ) Filter izes (inches) TD. xx xx xx xx xx xx xx xx Basic Unit Weight-LB. Blank-Off Plate Economizer hipping Weight-LB. Form No upersedes 32-7 Page 3 of

4 Cooling Application Data - Outdoor Temperature Return Air Model (DB/WB) 7/2 Total Cooling ensible Cooling W 0/7 Total Cooling ensible Cooling /72 Total Cooling ensible Cooling /2 Total Cooling ensible Cooling W24 0/7 Total Cooling ensible Cooling /72 Total Cooling ensible Cooling /2 Total Cooling ensible Cooling W 0/7 Total Cooling ensible Cooling /72 Total Cooling ensible Cooling /2 Total Cooling ensible Cooling W3 0/7 Total Cooling ensible Cooling /72 Total Cooling ensible Cooling /2 Total Cooling ensible Cooling W42 0/7 Total Cooling 4 4 ensible Cooling /72 Total Cooling ensible Cooling /2 Total Cooling ensible Cooling W4 0/7 Total Cooling ensible Cooling /72 Total Cooling ensible Cooling /2 Total Cooling ensible Cooling W 0/7 Total Cooling ensible Cooling /72 Total Cooling ensible Cooling /2 Total Cooling ensible Cooling W72 0/7 Total Cooling ensible Cooling /72 Total Cooling ensible Cooling Below F (.3C), unit requires a factory or field installed low ambient control. Outdoor temperatures given are for air entering condenser section inlets. Follow clearances given to ensure proper condenser airflow. Return air temperature. Cooling Capacity 7 F 0 F F 0 F F 0 F F F F F F Capacity Multiplier Factors % of Rated Airflow - Rated + Total BTUH ensible BTUH Unit Charge Rates - R4A UNIT td. Unit - Lbs. WAAP/LAP - EER Right & Left A/C 3.37 W24AAP/LAP - EER Right & Left A/C 4. WAAP/LAP - EER Right & Left A/C 3.7 W3AAP/LAP - EER Right & Left A/C 4.3 W42AAP/LAP - EER Right & Left A/C 4. W4AAP/LAP - EER Right & Left A/C.37 WAAP/LAP - EER Right & Left A/C 7.3 W72ABP/LBP - EER Right & Left A/C. Form No upersedes 32-7 Page 4 of

5 Electrical pecifications W**A eries MODEL WAAPA00,A0Z A0 A W24AAPA00, A0Z A04 A0 A W24AAPB00, B0Z Rated Volts & Phase 2/- 2/- No. Field Power Circuits B0 2/-3 W24AAPC00, C0Z 4-3 C0 WAAPA00, A0Z A0 2/- A A or 2 WAAPB00, B0Z B0 B0 B WAAPC00, C0Z C0 C0 C2 C W3AAPA00, A0Z A0 A A W3AAPB00, B0Z B0 B0 B W3AAPC00, C0Z C0 C0 C2 C 2/ /- 2/ or 2 Minimum Circuit Ampacity ingle Circuit Maximum External Fuse or Ckt. Brkr. 0 0 Min. Field Power Wire ize Ground Wire Multiple Circuit Minimum Maximum Circuit External Fuse Field Power Ground Ampacity or Ckt. Breaker Wire ize Wire ize Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on 7C copper wire. All wiring must conform to the National Electrical Code and all local codes. These Minimum Circuit Ampacity values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 3 for power conductor sizing. Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note of Table 3 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway. IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized over-current protection and conductor wires in accordance with the National Electrical Code and all local codes. Form No upersedes 32-7 Page of

6 Electrical pecifications W**A eries (continued) MODEL Rated Volts & Phase W42AAPA00, A0Z A 2/- A A W42AAPB00, B0Z B0 B0 2/-3 B B W42AAPC00, C0Z C0 4-3 C W4AAPA00, A0Z A 2/- A A W4AAPB00, B0Z B0 B0 2/-3 B B W4AAPC00, C0Z C0 4-3 C W4AAPQ00, Q0Z 7-3 Q WAAPA00, A0Z A 2/- A A WAAPB00, B0Z B0 B0 2/-3 B B WAAPC00, C0Z C0 4-3 C WAAPQ00, Q0Z 7-3 Q W72ABPA00, A0Z A 2/- A A W72ABPB00, B0Z B0 B0 2/-3 B B W72ABPC00, C0Z C0 4-3 C W72ABPQ00, Q0Z 7-3 Q No. Field Power Circuits or 2 or 2 or 2 or 2 or 2 or 2 2 or 2 or 2 or 3 2 Minimum Circuit Ampacity ingle Circuit Maximum External Fuse or Ckt. Brkr Min. Field Power Wire ize Ground Wire Multiple Circuit Minimum Maximum Circuit External Fuse Field Power Ground Ampacity or Ckt. Breaker Wire ize Wire ize Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on 7C copper wire. All wiring must conform to the National Electrical Code and all local codes. These Minimum Circuit Ampacity values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 3 for power conductor sizing. Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note of Table 3 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway. IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized over-current protection and conductor wires in accordance with the National Electrical Code and all local codes. Form No upersedes 32-7 Page of

7 Electrical pecifications W**L eries MODEL WLAPA0Z A0 A W24LAPA0Z A0 A W24LAPB0Z Rated Volts & Phase 2/- 2/- No. Field Power Circuits B0 2/-3 W24LAPC0Z 4-3 C0 WLAPA0Z A0 2/- A A or 2 WLAPB0Z B0 B WLAPC0Z C0 C W3LAPA0Z A A W3LAPB0Z B0 B W3LAPC0Z C0 C 2/ /- 2/ or 2 Minimum Circuit Ampacity ingle Circuit Maximum External Fuse or Ckt. Brkr. 0 0 Min. Field Power Wire ize Ground Wire Dual Circuit Minimum Maximum Circuit External Fuse Field Power Ground Ampacity or Ckt. Breaker Wire ize Wire ize Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on 7C copper wire. All wiring must conform to the National Electrical Code and all local codes. These Minimum Circuit Ampacity values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 3 for power conductor sizing. Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note of Table 3 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway. IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized over-current protection and conductor wires in accordance with the National Electrical Code and all local codes. Form No upersedes 32-7 Page 7 of

8 Electrical pecifications W**L eries MODEL W42LAPA0Z A A W42LAPB0Z B0 B0 B W42LAPC0Z C0 C W4LAPA0Z A A W4LAPB0Z B0 B0 B W4LAPC0Z C0 C W4LAPQ00, Q0Z Q WLAPA0Z A A WLAPB0Z B0 B0 B WLAPC0Z C0 C WLAPQ00, Q0Z Q W72LBPA0Z A A W72LBPB0Z B0 B0 B W72LBPC0Z C0 C W72LBPQ00, Q0Z Q Rated Volts & Phase 2/- 2/ /- 2/ /- 2/ /- 2/ No. Field Power Circuits or 2 or 2 or 2 or 2 or 2 Minimum Circuit Ampacity ingle Circuit Maximum External Fuse or Ckt. Brkr Min. Field Power Wire ize Ground Wire Dual Circuit Minimum Maximum Circuit External Fuse Field Power Ground Ampacity or Ckt. Breaker Wire ize Wire ize Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on 7C copper wire. All wiring must conform to the National Electrical Code and all local codes. These Minimum Circuit Ampacity values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 3 for power conductor sizing. Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note of Table 3 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway. IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized over-current protection and conductor wires in accordance with the National Electrical Code and all local codes. Form No upersedes 32-7 Page of

9 Indoor Blower Performance ( Hz) - CFM at Rated Voltage peed W W24 W W3 W42 W4 W W72 High Low ingle High Low High Low High Low High Low High Low High Medium Low EP (Inch H) Above data is with " standard throwaway filter and " washable filter. For optional 2" pleated filter - reduce EP by. in. ee installation instructions for maximum EP information on various KW application. Factory Connected peed. Electric Heat Table - Refer to Electrical pecifications for Availability by Unit Model Nominal KW Kw At 2V () At V () At V (2) At 4V (2) At 7V -Ph Amps 3-Ph Amps Btuh Kw -Ph Amps 3-Ph Amps Btuh Kw 3-Ph Amps Btuh Kw 3-Ph Amps Btuh Kw 3-Ph Amps Btuh , , , , , ,.0 7.2,47.2., , , , ,03.0., , , 7. 3., , ,3.0.0, ,0.0., , , ,434.., , , () These electric heaters are available in 2/V units only. (2) These electric heaters are available in V units only. Form No upersedes 32-7 Page of

10 Heater Packages - Field Installed "A" eries Right-Hand Units Designed for adding Electric Heat to 0 KW Units Circuit Breaker tandard on 2/V Models Air Conditioner Models -A00 Models 2/- ETL U & Canada Listed Toggle Disconnect tandard on 4V Models -B00 Models 2/-3 -C00 Models 4-3 Heater Model # KW Heater Model # KW Heater Model # KW WAAP EHW2TA- EHW2TA-A0 EHW2TA-A W24AAP EHWA2A-A04B EHW2TA- EHW2TA-A0 EHW2TA-A 4 EHW2TA-B0 EHWH24B-C0 WAAP EHW3TA- EHW3TA-A0 EHW3TA-A EHW3TA-A EHWA-B0 EHW3TA-B0 EHW3TA-B EHW3TA-C0 EHW3TA-C0 EHW3TA-C2 EHW3TA-C 2 W3AAP EHW3TA- EHW3TA-A0 EHW3TA-A EHW3TA-A EHW3TA-B0 EHW3TA-B0 EHW3TA-B EHW3TA-C0 EHW3TA-C0 EHW3TA-C2 EHW3TA-C 2 W42AAP W4AAP EHW4TA- EHW-AB EHW-AB EHW-AB EHW4TA-B0 EHW-B0B EHW-BB EHW4TA-B EHW4TA-C0 EHW4TA-C WAAP EHWTA- EHW-AB EHW-AB EHW-AB EHWA-B0B EHW-BB EHWTA-B EHW4TA-C0 EHW4TA-C W72ABP EHWTA- EHW72A-AB EHW72A-AB EHW72A-AB EHWTA-B0 EHW70A-B0B EHW-BB EHWTA-B EHW4TA-C0 EHW4TA-C Heater Packages - Field Installed "L" eries Left-Hand Units Air Conditioner Models -A00 Models 2/- -B00 Models 2/-3 -C00 Models 4-3 Heater Model # KW Heater Model # KW Heater Model # KW WLAP EHW2TA-L EHW2TA-A0L EHW2TA-AL W24LAP EHW2TA-L EHW2TA-A0L EHW2TA-AL EHW2TA-B0L WLAP EHW3TA-L EHW3TA-A0L EHW3TA-AL EHW3TA-AL EHW3TA-B0L EHW3TA-BL EHW3TA-C0L EHW3TA-CL W3LAP EHW3TA-L EHW3TA-AL EHW3TA-AL EHW3TA-B0L EHW3TA-BL EHW3TA-C0L EHW3TA-CL W42LAP W4LAP EHW4TA-L EHW-ALB EHW-ALB EHW4TA-B0 EHW-B0LB EHW-BLB EHW4TA-C0L EHW4TA-CL WLAP EHW4TA-L EHW-ALB EHW-ALB EHWA-B0LB EHW-BLB EHW4TA-C0L EHW4TA-CL W72LBP EHWTA-L EHW72A-ALB EHW72A-ALB EHW70A-B0LB EHW-BLB EHW4TA-C0L EHW4TA-CL Form No upersedes 32-7 Page of

11 Clearances Required for ervice Access and Adequate Condenser Inlet Airflow MODEL LEFT IDE RIGHT IDE WAAP, W24AAP, WAAP, W3AAP " " W42AAP, W4AAP, WAAP, W72ABP " " NOTE: For side-by-side installation of two (2) WA models, there must be inches between units. This can be reduced to inches by using a WL model (left side compressor and controls) for the left unit and WA (right side compressor and controls) for right unit. Allow feet between front of unit and walls or other barriers to avoid condenser discharge air circulation. Minimum Clearances Required to Combustible Materials MODEL UPPLY AIR DUCT FIRT THREE FEET CABINET WAAP, W24AAP 0" 0" WAAP, W3AAP /4" 0" W42AAP, W4AAP, WAAP, W72ABP /4" 0" Refer to the Installation Manual for more detailed information. Dimensions of W-72AA Basic Unit for Architectural & Installation Requirements (Nominal) MODEL WAAP W24AAP WAAP W3AAP W42AAP W4AAP WAAP W72ABP WIDTH (W) DEPTH (D) HEIGHT (H) UPPLY RETURN A B C B E F G I J K L M N O P Q R T W Built In Rain Hood 4 Pitch Heater Access Panel Electric Heat C. Breaker/ Disconnect Access Panel (Lockable) ECON Hood D A I ide Wall Mounting Brackets (Built In) Top Rain Flashing hipping Location E O.44 upply Air Opening B R F Ventilation Air C H Optional Electrical Entrances Return Air Opening G Cond. Air Outlet Low Voltage Electrical Entrance High Voltage Electrical Entrance Cond. Air Inlet J K L M P T Front View ide View Drain N Q Back View Bottom Installation Bracket MI-34 Form No upersedes 32-7 Page of

12 Clearances Required for ervice Access and Adequate Condenser Inlet Airflow MODEL LEFT IDE RIGHT IDE WLAP, W24LAP, WLAP, W3LAP " " W42LAP, W4LAP, WLAP, W72LBP " " NOTE: For side-by-side installation of two (2) WL models, there must be inches between units. This can be reduced to inches by using a WL model (left side compressor and controls) for the left unit and WA (right side compressor and controls) for right unit. Allow feet between front of unit and walls or other barriers to avoid condenser discharge air circulation. Minimum Clearances Required to Combustible Materials MODEL UPPLY AIR DUCT FIRT THREE FEET CABINET WLAP, W24LAP 0" 0" WLAP, W3LAP /4" 0" W42LAP, W4LAP, WLAP, W72LBP /4" 0" Refer to the Installation Manual for more detailed information. Dimensions of W-72LA Basic Unit for Architectural & Installation Requirements (Nominal) MODEL WLAP W24LAP WLAP W3LAP W42LAP W4LAP WLAP W72LBP WIDTH (W) DEPTH (D) HEIGHT (H) UPPLY RETURN A B C B E F G I J K L M N O P Q R T R E Heater O 4 Pitch Access.44 Panel D W upply Air Opening B ide Wall Mounting Brackets (Built In) Top Rain Flashing hipping Location Built In Rain Hood 2.3 A I.0 Electric Heat C. Breaker/ Disconnect Access Panel (Lockable) Econ. Hood Return Air Opening Optional Electrical Entrances C Ventilation Air F T Drain Bottom Installation Bracket Back View Q P M N L H K J Cond. Air Inlet ide View Low Voltage Electrical Entrance High Voltage Electrical Entrance Condenser Air Outlet Front View G MI-34 Form No upersedes 32-7 Page 2 of

13 MULTI-TEC Control equence of Operation & Logic The MULTI-TEC unit programmable logic board uses a technologically advanced series of sequences to control unit operation. These sequences can be defined in the following processes: Alarm Logic Indoor Blower Control Temperature Control Free Cooling Operation Compressor Logic The processes listed are described in detail below. Alarm Logic High Mixed Air Alarm If the mixed air temperature sensor is above cooling temperature setpoint for longer than seconds, the wall unit will generate a high mixed air alarm. Low Mixed Air Alarm If the mixed air temperature sensor is below F for longer than seconds, the wall unit will generate a low mixed air alarm. Refrigerant Low Pressure When the low pressure switch indicates a low pressure condition and there is an active call for cooling, the controller will generate an alarm after a delay. The delay used by the low pressure alarm is determined by the outdoor air temperature. If the outdoor air temperature is below F, the delay is 0 seconds. If the outdoor temperature is above F, the delay is seconds. Additionally, if the outdoor temperature sensor is not used, the delay is set to 0 seconds. The controller will try to run the refrigeration system three (3) times before the alarm will lock the compressor out. Economizer Damper: When the controller commands the economizer damper actuator to a position other than 0% and the damper switch indicates the damper is not open after a delay of seconds, the controller will generate a damper failed to open alarm. When the controller commands the economizer damper actuator to the 0% position and the damper switch indicates the damper is not closed after a delay of 0 seconds, the controller will generate a damper failed to close alarm. Freeze tat Alarm: When the coil temperature is below F for longer than seconds, the controller will generate a freeze stat alarm. This will then change the blower to high speed and turn off the compressor for 0 seconds or reset once the temperature has reached F above the freeze stat temperature set point. Fan tatus Alarm If the fan is commanded on and the fan status switch has not indicated the fan is running within 4 seconds, the system will generate and alarm. Form No upersedes 32-7 Page 3 of

14 Indoor Blower Control The fan will be enabled if the system is set for continuous blower, economizer enabled, cooling stage, cooling stage 2, heating stage, heating stage 2, freeze stat on, or a run test is started. Temperature Control Zone election Based on the zone setting (average or highest), the unit will decide which zone control temperature to use. The control temperature is an average of the zone temperature sensors and the return air temperature sensors in each zone. Cooling equence (Economizer Available) Field-Adjustable If the zone control temperature is higher than 7 F and outdoor conditions are acceptable for economizing, the unit will enable the economizer. If the zone control temperature is higher than 0 F, the unit will enable mechanical cooling stage. If the zone control temperature is higher than F, the unit will enable mechanical cooling stage 2. Cooling equence (Economizer Not Available) Field-Adjustable If the zone control temperature is higher than the cooling setpoint, the unit will enable stage mechanical cooling. If the zone control temperature is higher than 0 F, the unit will enable stage 2 mechanical cooling. Heating equence: Field-Adjustable If the zone control temperature is below F, the unit will enable electric heat stage. If the zone control temperature is below 7 F, the unit will enable electric heat stage 2. If the zone control temperature is below F, the unit will enable electric heat stage 3. Free Cooling Operation Economizer Enable The economizer will be enabled for cooling operation if the following conditions are true: None Economizer will not be enabled. Bulb Only Field-Adjustable. Outdoor air temperature is below 70 F. 2. Indoor zone relative humidity is below 70% (with LC only). Temperature & Humidity Field-Adjustable. Outdoor air temperature is below 70 F. 2. Outdoor relative humidity is below % (without LC indoor zone humidity sensor) or 0% (with LC indoor humidity sensor). 3. Indoor zone relative humidity is below 70% (with LC indoor RH sensor only). Enthalpy (Temperature, Humidity & Dewpoint) Field-Adjustable. Outdoor air temperature is below 70 F. 2. Outdoor relative humidity is below % (without LC indoor zone humidity sensor) or 0% (with LC indoor humidity sensor). 3. The outdoor air dewpoint is less than F. 4. Indoor zone relative humidity is below 70% (with LC indoor RH sensor only). Compressor Logic Enable The compressor will be enabled when stage is enabled and outdoor air conditions are not acceptable for economizing. If the conditions are acceptable, the compressor will run when stage 2 is enabled. Delays & Run Time Field-Adjustable The compressor will have a minimum run time of seconds and a minimum off time of seconds. Form No upersedes 32-7 Page 4 of

15 tandard & Optional Accessory Functionality LC00 Controller: The LC00 is Bard s premier control device for electronics shelters, equipment buildings, pump houses and modular buildings. A logic board inside the LC controller communicates with logic boards in the MULTI-TEC units to decide when to cool the area, and what mode of cooling to use if economizers are installed. Cooling modes include unit rotation and intuitive load balancing. Energy efficiency and consistent area temperature control are maximized for reliable equipment cooling. Humidity monitoring inside the shelter helps reduce the chance of condensation forming on equipment and electronics and can be controlled with optional equipment. An N+ ( extra backup unit) operation or a localized load-based strategy can be used for better temperature control when using multiple units. The controller is able to be installed in any area inside the structure with the use of remote temperature sensors, and can operate with 3 separate zones or areas including office spaces and battery rooms. th-tune Controller (-24): The th-tune controller can be used to operate one unit independent of the LC controller. The th-tune acts as a simple thermostat and connects to one unit using standard Ga. twisted pair wiring. The TEC- EYE TM service tool (provided in the kit) is used to program and setup the MULTI-TEC unit. The th-tune controller does not connect to the LC controller and does not have remote alarming capability. EMI Ferrite Filter (-0): An EMI filter is used to suppress interference that may be present on the connecting (2) wire twisted pair between the MULTI-TEC units and LC controller. When connecting all units together in series through a daisy chain connection, a total of (2) EMI filters are needed. One filter is placed at the 2 wire connection to the LC controller. The other filter is placed at the 2 wire connection point where the unit at the end of the chain is connected. If two separate daisy chain connections are made, a total of (2) EMI filters are needed, one EMI filter is needed at the 2 wire connection point of each end unit. TEC-EYE TM ervice Tool (-0): The TEC-EYE TM service tool is used for system setup and troubleshooting. An easy to read backlit display and -button control is provided. Used as a display and interface, the tool is able to interact with the microprocessor on the logic board located in the LC controller and in the MULTI-TEC unit. A foot communication cable with RJ connectors is provided with the TEC-EYE TM. (Included with every LC00 & -24 th-tune control package.) Form No upersedes 32-7 Page of

16 MULTI-TEC Unit Controllers MODEL Controller Logic Voltage hipping English panish French Fahrenheit Weight Celsius No. of Units Controlled Unit moke Zones Models Detector Unit Connection Remote Communication & Diagnostics LC00 PLC V/2V-2V / Hz AC 23 lbs. Yes Yes Yes Yes/Yes 4 WA with PLC 3 Yes Daisy Chain Daisy Chain th-tune Controller #-24 PLC 24V lb. Yes Yes Yes Yes/Yes WA with PLC No ingle Unit ingle Unit The LC00 and th-tune Controller #-24 are shipped with a TEC-EYE TM diagnostic tool. The th-tune Controller #-24 does not include alarm functionality or remote communication. ystem setup requires the use of the TEC-EYE TM diagnostic tool. MULTI-TEC tandard and Optional Accessories Part Number -0 Description EMI Ferrite Filter ( needed for each unit connection to Controller) Included with LC TEC-EYE TM (ervice Tool), ft. communication cable Remote Temperature & Humidity ensor w/' wire (2 additional sensors may be used) Remote Temperature ensor ( additional sensor may be used) Optional EMI Ferrite Filter Part #-0 TEC-EYE TM Part #-0 Controller Version Nomenclature LC 00-0 LC Controller Model Controller Version Form No upersedes 32-7 Page of

17 oftware Version Nomenclature LC 00. LC Controller oftware Model oftware Version The Bard MULTI-TEC Wall Mount unit contains an advanced PLC logic board with on-board software similar to a computer. When buying additional MULTI-TEC Wall Mount units for an existing project, it is important for all units and the LC controller to contain the same software version. The easiest method of ensuring all the units and the LC controller have the same software is to use a laptop computer to download the latest software for the new MULTI-TEC unit or LC controller from the internet and using a MicroUB cable reprogram all existing equipment. Additional MicroUB cables can be found at most stores carrying phones and electronics equipment. Using the MicroUB Cable to Update oftware #.) Download new program from the Bard oftware Download page. #2.) Replace old program in existing equipment using Micro UB cable. oftware Website Current versions of software and/or software information for all controllers and unit equipment may be found at: Form No upersedes 32-7 Page 7 of

18 Air Conditioning Wall-Mount Model Nomenclature W 3 A A P A X X X X E ERIE NOMINAL CAPACITY - ½ Ton 24-2 Ton - 2½ Ton 3-3 Ton 42-3½ Ton 4-4 Ton - Ton 72 - Ton A = Compressor & Controls - Right ide L = Compressor & Controls - Left ide P = PLC Logic Board M = Mechanical Dehumidification (TBR) E = Electrical Reheat Dehumidification (TBR) Economizer REVIION A = W - W B = W72 VOLT & PHAE A - 2/// B - 2///3 C - 4//3 Q- 7//3 MI-377 KW VENTILATION OPTION B = Blank-Off Plate = Economizer: Default Enthalpy convert to DB only FILTER OPTION X - -inch Throwaway (tandard) W - -inch Washable P - 2-inch Pleated (MERV ) N - 2-inch Pleated (MERV ) M - 2-inch Pleated (MERV 3) For 0KW and circuit breakers (2/ Volt) or toggle disconnects (4 Volt) applications, insert 0Z in the KW field of the model number. ee Pages & for available Factory Installed KW options and Page for Field Installed Heater Packages. Ventilation ystem Packages MULTI-TEC tandard Controls COLOR OPTION X - Beige (tandard) - White 4 - Buckeye Gray - Desert Brown - Dark Bronze A - Aluminum - tainless UPPLY AIR OUTLET X - Front (tandard) CONTROL MODULE E = LAC C = LAC & CCH (W includes crankcase heater as standard.) COIL OPTION X - tandard - Phenolic Coated Evaporator 2 - Phenolic Coated Condenser 3 - Phenolic Coated Evaporator and Condenser 4 - Condenser ection Component Coating, Coated Evaporator and Condenser - Internal and External Cabinet Component Coating, Coated Evaporator and Condenser ECONOMIZER OPTIONAL The optional built-in economizer system is internally mounted behind the service door and allows outdoor air to be introduced through the air inlet openings. The amount of outdoor air varies in response to the system controls and settings defined by the end user. It includes a built-in exhaust air damper. The economizer is designed to provide free cooling when outside air conditions are cool and dry enough to satisfy cooling requirements without running the compressor. This in turn provides lower operating costs, while extending the life of the compressor. tandard Features: Full rated outdoor intake Fully modulating Hi-Torque Actuator 7" intake hood with filter imple single blade design Positive shut-off with non-stick gaskets Electronic Enthalpy sensors PLC control module with precision settings and diagnostics High Pressure witch: Required afety Device that also provides protection to the compressor system when system refrigerant pressure is above an acceptable level. Auto Reset, psig. Output to compressor control module. Low Pressure witch: Provides protection to the compressor when refrigerant pressure falls below an acceptable level. Auto Reset, cut out at psig. Output to compressor control module. Low Ambient Control: Modulating control that removes power from the condenser fan to allow for unit compressor cooling operation at outdoor ambient temperatures below F. Factory set for system performance. crew-on connection for easy servicing. Output to condenser fan motor. Compressor Control Module: Compressor protection device that has a -second to -minute timer. This module features a delay-on-make for initial startup for a minimum of 2 minutes plus % of the timer setting. There is no delay during routine operation. Allows one automatic retry after high pressure switch activation, then goes into hard lockout mode. Output to PLC logic board. tart Assist (ingle Phase Models Only): PTCR motor starting device increases compressor motor torque 2-3 times. upply Air ensor: K Thermistor measures supply air temperature, output to PLC logic board. Return Air ensor: K Thermistor measures return air temperature, output to PLC logic board. Evaporator ensor: K Thermistor prevents coil freezing due to low return air temperature. Output to PLC logic board. Outdoor Temperature & Enthalpy ensor: K Temperature sensor and 4-mA humidity transmitter, output to PLC logic board (PLC defaults to temperature only). Phase Monitor (3-Phase Models Only): Prevents 3-phase compressor operation to protect the compressor if the device senses incorrect phasing. LED indicator light. Filter witch: Adjustable switch to indicate the unit air filter needs to be replaced. Output to PLC logic board. MULTI-TEC Optional Controls Compressor Crankcase Heater: 2-wire heater that prevents refrigerant migration and mixing with crankcase oil when the unit is off, prevents condensation of refrigerant in the crankcase of the compressor, and keeps refrigerant at a temperature higher than the coldest part of the system. Recommended for Canada and cold climate compressor operation. Form No upersedes 32-7 Page of Bard Manufacturing Company, Inc. Bryan, Ohio Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Form No. 32 March upersedes: 32-7

THE MULTI-TEC WALL-MOUNT AIR CONDITIONERS 10 EER (50 HZ) WITH LOGIC BOARD

THE MULTI-TEC WALL-MOUNT AIR CONDITIONERS 10 EER (50 HZ) WITH LOGIC BOARD The MULTI-TEC Wall-Mount Air Conditioner utilizes PLC (Programmable Logic Control) technology to allow multiple units to operate connected to a single LC6000 controller. When installed with an optional

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONER - 9. EER, (HZ) Model W7A2 Right-ide Control Panel Model W7L2 Left-ide Control Panel Ton (, Btuh) For Export Only The Bard Wall-Mount Air Conditioner is a self contained energy

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONER -. EER, (HZ) Models WAA to W72AA Right-ide Control Panel Models WLA to W72LA Left-ide Control Panel. to Ton (7, to 7, Btuh) Green Refrigerant R-A The Bard Wall-Mount Air

More information

THE WALL-MOUNT AIR CONDITIONERS (50HZ)

THE WALL-MOUNT AIR CONDITIONERS (50HZ) THE WALL-MOUNT AIR CONDITIONER (50HZ) Models W24A2 to W70A2 Right ide Control Panel Models W24L2 to W70L2 Left ide Control Panel 2,600 Btuh (6.33 KW) 62,000 Btuh (8.6 KW) For Export Only The Bard Wall-Mount

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONER -. EER, (HZ) Models W7A to W7A Right-ide Control Panel Models W7L to W7L Left-ide Control Panel. to Ton (, to, Btuh) The Bard Wall-Mount Air Conditioner is a self contained

More information

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit D35A/L 1-tage Right & Left-Hand Control Panel The Bard DUAL-TEC Wall Mount Air Conditioners with -48VDC Blower

More information

WALL-MOUNT HEAT PUMPS - (60HZ)

WALL-MOUNT HEAT PUMPS - (60HZ) WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to 5,000 Cooling Capacities:,00 to 5,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to,000 Capacities:,00 to,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling system, which

More information

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit D36A/L 1-tage Right & Left-Hand Control Panel Green Refrigerant R-410A The Bard DUAL-TEC Wall Mount Air Conditioners

More information

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features THE WALL-MOUNT ONE TON AIR CONDITIONER W2A,800 Btuh 9.00 EER Right Side Control Panel 60Hz GREEN REFRIGERANT R-A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating

More information

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features THE WALL-MOUNT ONE TON AIR CONDITIONER W2AAA 2,000 Btuh.00 EER Right Side Control Panel 60Hz Green Refrigerant R-4A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating

More information

THE WALL-MOUNT Quiet Climate A/C 10.0 EER

THE WALL-MOUNT Quiet Climate A/C 10.0 EER THE WALL-MOUNT Quiet Climate A/C. EER Models WA, W9A, WA to Ton (, to, Btuh) Right Side Control Panel Hz GREEN REFRIGERANT R-A The Bard Wall-Mount Air Conditioner is a self contained energy efficient system,

More information

Green Refrigerant. THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 15.3 BTU/WATT. Engineered Features

Green Refrigerant. THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 15.3 BTU/WATT. Engineered Features THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 5.3 BTU/WATT WA3S WA5S Right Side Control Panel WL3S WL5S Left Side Control Panel 3 to 5 Ton (35,2 to 5,5

More information

THE WALL-MOUNT TM SIX TON AIR CONDITIONER

THE WALL-MOUNT TM SIX TON AIR CONDITIONER The Bard Wall-Mount Six Ton Air Conditioner is a self contained energy efficient system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or

More information

THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS

THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS Models: SH to SH Up to.5 EER Heating Capacities: 2, to, BTUH Cooling Capacities: 2, to 55, BTUH Green Refrigerant R-A The Bard Wall-Mount Heat Pump is a self-contained

More information

The Wall-Mount Variable Capacity Environmental Control Units. Green Refrigerant

The Wall-Mount Variable Capacity Environmental Control Units. Green Refrigerant The Wall-Mount Variable Environmental Control Units Bard is an ISO 00:200 Certified Manufacturer, 5 and -Ton Variable ECU Dual /50 Hz Frequency Cooling Op Range -40F to +F ODT The Bard Variable ECU design

More information

THE WALL-MOUNT GAS/ELECTRIC Low NOx Certified Models

THE WALL-MOUNT GAS/ELECTRIC Low NOx Certified Models Models: W24G3 to WG3 Up to 1.5 EER 26, to 57,5 BTUH Cooling Capacity 37, to 74, BTUH Heating Capacity The Bard Wall-Mount Electric Air Conditioner with gas fired heating is a self contained energy efficient

More information

THE WALL-MOUNT HEAT PUMPS EER, (60HZ)

THE WALL-MOUNT HEAT PUMPS EER, (60HZ) THE WALL-MOUNT HEAT PUMPS -. EER, (HZ) Models: Heating Capacities: Cooling Capacities: Engineered Features WHA to WHA Hz (,5 to 5,5 Btuh) (7, to 5, Btuh) The Bard Wall-Mount Heat Pump is a self contained

More information

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models WG3S2, WG4S2, WG5S2 6HZ 24, to 56,5 BTUH Cooling Capacity 37,

More information

Q-TEC QC-Series Chilled Water Air Conditioner

Q-TEC QC-Series Chilled Water Air Conditioner Cooling Capacities: 13,3 to 49,3 BTUH (Based on EWT, GPM & CFM) Q-TEC QC-Series Chilled Water Air Conditioner The Q-TEC Series self-contained packaged chilled water air conditioner is designed to be installed

More information

Q-TEC Q24A-Q60A Air Conditioners

Q-TEC Q24A-Q60A Air Conditioners The Q-TEC Series self contained packaged air conditioner is designed to be installed inside a building structure against an exterior exposed wall. Q-TEC s design provides whisper quiet operation with total

More information

THE WALL-MOUNT 6-TON AIR CONDITIONERS

THE WALL-MOUNT 6-TON AIR CONDITIONERS THE WLL-MOUNT -TON IR CONDITIONERS Model W7 - Right Side Control Panel Model W7L - Left Side Control Panel, Btuh 9.5 EER Hz The Bard Wall-Mount ir Conditioner is a self contained energy efficient system,

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A THE WALLMOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To. BTU/WATT WAS, WAS, WAS to Ton (,0 to,00 Btuh) Right Side Control Panel 0Hz GREEN REFRIGERANT RA The Bard

More information

Q-Tec TM QC-Series Chilled Water Air Conditioner

Q-Tec TM QC-Series Chilled Water Air Conditioner Q-Tec TM QC-Series Chilled Water Air Conditioner Cooling Capacities:, to, BTUH (Based on EWT, GPM and ) The Q-Tec Series self-contained packaged chilled water air conditioner is designed to be installed

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A THE WLL-MOUNT IR CONDITIONERS -. EER, (HZ) Models W7 to W. to Ton (, to, Btuh) Right Side Control Panel Hz The Bard Wall-Mount ir Conditioner is a self contained energy efficient system, which is designed

More information

Q-TEC Q24H3-Q60H3 Air-to-Air Heat Pump 10 EER Units

Q-TEC Q24H3-Q60H3 Air-to-Air Heat Pump 10 EER Units Heating Capacities: Cooling Capacities: Q-TEC Q2H3-QH3 Air-to-Air Heat Pump 0 EER Units 23,0 to,000 Btuh,000 to 5,0 Btuh The Q-TEC Series self contained packaged heat pump is designed to be installed inside

More information

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide 1.0 GENERAL Furnish and install a self-contained, vertical, exterior wall mount, electric air conditioner

More information

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB BARD MANUFACTURING COMPANY, INC. W18AA-W72AB Series Right-Side Access Air Conditioner W18LA-W72LB Series Left-Side Access Air Conditioner Engineering Specification Guide 1.0 GENERAL Furnish and install

More information

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES 180-300 INGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNIT 15-25 NOMINAL TON ubmittal Data DECRIPTION The units are one -piece electric cooling/optional electric heating units, prewired and precharged.

More information

Product Guide. Wallmount. Air Conditioners & Heat Pumps

Product Guide. Wallmount. Air Conditioners & Heat Pumps Product Guide Wallmount Air Conditioners & Heat Pumps Standard Features page 2 All Major Components can be Accessed from the Front 00 Hour Salt Spray rated powder coated baked paint finish AHRI certified

More information

MEGA-TEC TM 10EER 10 Ton Capacity Air Conditioners

MEGA-TEC TM 10EER 10 Ton Capacity Air Conditioners MEGA-TEC TM 10EER 10 Ton Capacity Air Conditioners Bard Manufacturing's revolutionary MEGA-TEC WALL-MOUNT sets the industry standard for flexibility. Engineered to cool virtually any equipment building

More information

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH R EQUIPMENT ARI STANDARD 210 ARI STANDARDS ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP12-20-24-30-36-42-48-60-72 General

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS MODELS WA3 WA42 WA42 WA49 WA2 Bard Manufacturing Company Bryan, Ohio 4350 Since 94...Moving ahead just as planned. Manual : 20-2J Supersedes:

More information

Installation Instructions

Installation Instructions Installation Instructions Wall Mounted Packaged Air Conditioner Models: WA8, WA24 MIS-656 Bard Manufacturing Company Bryan, Ohio 43506 Since 94...Moving ahead, just as planned. Manual No.: 20-200K Supersedes:

More information

Q/Tec TM QH-Series 2 Air-to-Air Heat Pumps

Q/Tec TM QH-Series 2 Air-to-Air Heat Pumps Heating Capacities: 2, to 7, BTUH Capacities:, to 2, BTUH The Q/Tec Series self-contained packaged heat pump is designed to be installed inside a building structure against an exterior exposed wall. Q/Tec

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS MODELS WA3 WA43 WA44 WA49 WA Bard Manufacturing Company Bryan, Ohio 4350 Since 94...Moving ahead just as planned. Manual : 0-39 Supersedes:

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGED AIR CONDITIONER Models: W7A2-A WA2-A W24A2-A W24A2-B W24A2-C W24A2-D W24A2-F WA2-A WA2-B WA2-C WA2-D WA2-F WA2-A WA2-B WA2-C WA2-D WA2-E WA2-F W42A2-A W42A2-B

More information

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide 1.0 GENERAL Furnish and install a self-contained, vertical, exterior wall mount, electric air conditioner

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS Model: WA121 Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual : 2100-234 G Supersedes: 2100-234

More information

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA PRODUCT DATA SHEET 1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac air conditioner is a cost-effective vertical, wall mounted air

More information

General Description. Operation

General Description. Operation ECUA12ACA & ECUA18ACA SlimPac (1 & 1.5 Ton) Environmental Control Units General Description The Industrial Climate Engineering SlimPac line of Environmental Control Units (ECU) are designed for the telecommunication

More information

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners PRODUCT DATA SHEET 9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Eubank WalPac A/C 9 air conditioner is a cost-effective vertical,

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A PH-SERIES PCKGED HET PUMPS Cooling Capacities: 2, to 6, Heating Capacities:, to 2, SEER:. HSPF: GREEN REFRIGERNT R-4 FRONT (INDOOR IRFLOW) END OF UNIT CK (OUTDOOR IRFLOW) END OF UNIT Standard Engineered

More information

BARD FUSION-TEC TM WALL-MOUNT TM Free Cooling Economizer and Air Conditioner

BARD FUSION-TEC TM WALL-MOUNT TM Free Cooling Economizer and Air Conditioner BARD FUSION-TEC TM WALL-MOUNT TM Free Cooling Economizer and Air Conditioner Bard High Sensible Cooling Systems HR36 Series 12.5 EER 2 to 3 Ton HR58 Series 11.0 EER 3.5 to 5 Ton The FUSION-TEC TM has been

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS MODELS J7A2 J7L2 J24A2 J24L2 JA2 JL2 J3A2 J3L2 J42A2 J42L2 J4A2 J4L2 JA2 JL2 J70A2 J70L2 Manual : 0-5A Supersedes: 0-5 File: Volume III Tab

More information

General Description. Safety Listed

General Description. Safety Listed ECUA90/120/150/180/240 & ECUDA180/240/300/360 (7.5, 10, 12.5, 15, 20, 25 & 30 Ton) Vertical Wall Mount Air Conditioners General Description Industrial Climate Engineering s air conditioners are used primarily

More information

Wall Mounted Air Conditioners with Gas Heat Models AVGA

Wall Mounted Air Conditioners with Gas Heat Models AVGA PRODUCT DATA SHEET Wall Mounted Air Conditioners with Gas Heat Models AVGA24-30-36-42-48-60 General Description The Marvair GPac wall mounted air conditioner with gas heat is designed for use on a variety

More information

Q/Tec TM QA-Series Air Conditioners

Q/Tec TM QA-Series Air Conditioners Q/Tec TM QASeries Air Conditioners The Q/Tec series self contained packaged air conditioner is designed to be installed inside a building structure against an exterior exposed wall. Q/Tec s design provides

More information

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH R EQUIPMENT ARI STANDARD 210 ARI STANDARDS GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP24-30-36-42-48-60 General Description The Marvair

More information

General Description. Safety Listed

General Description. Safety Listed ECUA90/120/150/180/240 & ECUDA180/240/300/360 (7.5, 10, 12.5, 15, 20, 25 & 30 Ton) Vertical Wall Mount Air Conditioners General Description Industrial Climate Engineering s air conditioners are used primarily

More information

LC6000 Controller used with MULTI-TEC Wall Mount Units Specification Sheet & Application Guide

LC6000 Controller used with MULTI-TEC Wall Mount Units Specification Sheet & Application Guide LC6000 Controller used with MULTI-TEC Wall Mount Units Specification Sheet & Application Guide FEATURES OF THE LC6000 CONTROLLER Control up to 14 units with a single LC6000 controller. Complete control

More information

Q/Tec TM QW-Series Water-to-Air Heat Pumps

Q/Tec TM QW-Series Water-to-Air Heat Pumps Heating Capacities: 6,4 to 45,5 BTUH Capacities:, to 53,5 BTUH : 3. to 3.5 : 3.4 to 6.6 Q/Tec TM QW-Series Water-to-Air Heat Pumps The Q/Tec series self contained packaged water-to-air heat pump is designed

More information

ComPac I & ComPac II 2 to 6 Ton Vertical Wall Mount Air Conditioners

ComPac I & ComPac II 2 to 6 Ton Vertical Wall Mount Air Conditioners ComPac I & ComPac II 2 to 6 Ton Vertical Wall Mount Air Conditioners Models AVPA24-30-36-42-48-60-72 (Single Stage Compressor) Models HVEA24-30-36-42-49-60 (Single Stage Compressor) Models HVESA36-42-49-60

More information

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA24-30-36-42-49-60 and HVPSA36-42-49-60 General Description HIGH EFFICIENCY - The Marvair Classic 13 High Efficiency Series

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS W12A2-A W12A1-K

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS W12A2-A W12A1-K INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS Model: W12A2-A W12A1-K Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual: 2100-509E Supersedes:

More information

SERVICE INSTRUCTIONS

SERVICE INSTRUCTIONS SERVICE INSTRUCTIONS MULTI-TEC WALL-MOUNT AIR CONDITIONER Part of the Bard Free Cooling Unit System W18AAPA W24AAPA W24AAPB W24AAPC W30AAPA W30AAPB W30AAPC W36AAEA W36AAEB W36AAEC W36AAMA W36AAMB W36AAMC

More information

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons 0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can

More information

1.5 to 3 Ton 208V to 460V 60hz Air Conditioner Specifications

1.5 to 3 Ton 208V to 460V 60hz Air Conditioner Specifications .5 to 3 Ton 2V to 4V hz Air Conditioner Specifications EER WA Series WALL-MOUNT.5 to 3 Ton V to 4V EER hz AirWA Conditioner Specifications. TM Series WALL-MOUNT Wall-Mount Air Conditioner is a self nergy

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH381 WH431 WH491

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH381 WH431 WH491 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS Models WH3 WH43 WH49 Bard Manufacturing Company, Inc. Bryan, Ohio 436 Since 94...Moving ahead just as planned. Manual : 20-342I Supersedes: 20-342H

More information

48PGD/E/F/L/M/N PG20-28

48PGD/E/F/L/M/N PG20-28 48/50PG-10SB 48PGD/E/F/L/M/N20-28 50PG20-28 SINGLE-PACKAGE COOLING UNITS WITH FACTORY-INSTALLED GAS HEAT SINGLE-PACKAGE COOLING UNITS WITH OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( ) (N,P)R SPLIT SYSTEM HEAT PUMP For Use With R --- 22 Refrigerant 1---1/2 TO 5 TONS (018 --- 060) Product Data *Units factory---shipped with no refrigerant. Dry nitrogen charge only. FEATURES AND BENEFITS

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0

More information

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Single Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that

More information

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION 100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest

More information

PRODUCT DATA SHEET. Models ASDCA/HSDCA & ASDCHA

PRODUCT DATA SHEET. Models ASDCA/HSDCA & ASDCHA PRODUCT DATA SHEET DC Free Air HVAC Unit w/48 VDC Evaporator Fan Motor, 00% Free Cooling and CoolLinks Controller Models ASDCA/HSDCA36-42-48-60-72 & ASDCHA36-42-48-60 General Description The Marvair ComPac

More information

Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST Base eries Fan Coil izes 001 thru 004 Product Data AIR HANDLER TECHNOLOGY AT IT FINET The series fan coils are reliable, dependable, and a great value. These fan coils offer air handling for practical,

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

10EER 7.5 Ton Vertical Wall Mount Air Conditioners Model AVHDA90 (Dual Compressor)

10EER 7.5 Ton Vertical Wall Mount Air Conditioners Model AVHDA90 (Dual Compressor) PRODUCT DATA SHEET 10 7.5 Ton Vertical Wall Mount Air Conditioners Model AVHDA90 (Dual Compressor) General Description Marvair s AVHDA ComPac air conditioners are used primarily to cool electronic and

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP Models WH84 WH242 Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 94...Moving ahead just as planned. Manual : 200-423C Supersedes: 200-423B

More information

2 shp 13 lc 1 36 t - 1 a

2 shp 13 lc 1 36 t - 1 a HEAT PUMPs 2SHP3 PRODUCT SPECIFICATIONS Dry Charge Split System - 60 HZ Bulletin No. 20645 July 203 Supersedes June 202 3 to 5 Tons MODEL NUMBER IDENTIFICATION 2 shp 3 lc 36 t - a Refrigerant Type 2 =

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality

More information

Hazardous Location Certified

Hazardous Location Certified Certified. Not Modified. EONA2-72 and EXNDA/EONDA90-240 2,000 BTUH (3.5Kw) to 240,000 BTUH (70.3Kw) Increased Safety Vertical Wall Mount Air Conditioners General Description EXNA60 The old approach to

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

GreenPac & GreenPac HGR Air Conditioners Single stage models AVPA and HVEA and 2-stage models HVESA

GreenPac & GreenPac HGR Air Conditioners Single stage models AVPA and HVEA and 2-stage models HVESA General Description The Marvair GreenPac and GreenPac HGR (Hot Gas Reheat) air conditioners are complete, factory assembled wall-mounted systems designed to provide total comfort while meeting ventilation

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw) Product Data 38AH024-134 Commercial Air-Cooled Condensing Units 50/60 Hz 20 to 130 Nominal Tons (63 to 390 Nominal kw) a38-4143ef 38AH044-134 These dependable split systems match Carrier s 40RM or 39 Series

More information

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAD3 Product Specifications 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGED HEAT PUMP Models: S2H-A S2H-B S2H-C SH-A SH-B SH-C SH-A SH-B SH-C S4H-A S4H-B S4H-C S49H-A S49H-B S49H-C SH-A SH-B SH-C S2HDA S2HDB S2HDC SHDA SHDB SHDC

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

Submittal Summary Page

Submittal Summary Page ate 05/24/2011 Project Name ouglas Middle School Project Number Client / Purchaser Submittal Summary Page Qty Tag # Model # escription 1 RTU- Cafeteria 15 Ton, Johnson Controls Series 20 Single Packaged

More information

Models: Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel. Blower Assembly

Models: Contents. Cabinet Components. Functional Components  Exploded View... 3  Usage List Control Panel. Blower Assembly REPLACEMENT PART MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: WA0, WA7 General Notes! Revised and/or additional pages may be issued from time to time.! A complete and current manual consists of

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION AIR CONDITIONERS 2scu3 PRODUCT SPECIFICATIONS Dry Charge Split System - 60 HZ Bulletin No. 20644 May 204 Supersedes September 203 3 to 5 Tons MODEL NUMBER IDENTIFICATION 2 scu 3 lc 36 t - a Refrigerant

More information

GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A

GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step- Heat Pump R-410A Ground Water Application: Water Temp 45 to 75 Ground Loop Application: Temp Range to 110 The Bard GEOTEC Geothermal/Water

More information

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH 233 CWA2 NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool with Electric Heat Multiposition Fan Coil Nominal

More information

High Heat COP. High/Low Stage

High Heat COP. High/Low Stage SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS WALL-MOUNTED VARIABLE CAPACITY ENVIRONMENTAL CONTROL UNIT Models: W3RV2-R W3RV2-S W3RV2-T W3LV2-R W3LV2-S W3LV2-T W5RV2-R W5RV2-S W5RV2-T W5LV2-R W5LV2-S W5LV2-T W6RV2-S W6RV2-T

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGED AIR CONDITIONER Models: WAA-A W2AA-A W2AA-B W2AA-C W2AA-D W2AA-F WAA-A WAA-B WAA-C WAA-D WAA-F W3AA-A W3AA-B W3AA-C W3AA-D W3AA-E W3AA-F W2AA-A W2AA-B W2AA-C

More information

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

13 GEP A L P - 1 A

13 GEP A L P - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800

More information