MDVS Tag: DF-1, DF-2. Architect/Engineer: Contractor: EXHAUSTO Job File: Use. Sizes. Listings. Description. CSI Specifications.

Size: px
Start display at page:

Download "MDVS Tag: DF-1, DF-2. Architect/Engineer: Contractor: EXHAUSTO Job File: Use. Sizes. Listings. Description. CSI Specifications."

Transcription

1 Submittal Data MDVS Tag: DF-1, DF-2 Job Name: Parkside Memory Cottage ALF Representative: Tom Barrow Company Job Location: Port Charlotte, FL Job #: Architect/Engineer: Contractor: EXHAUSTO Job File: Use The MDVS TM, Modulating Dryer Venting System, is a mechanical exhaust system used to control and maintain proper pressure and exhaust for multiple commercial or industrial laundry dryers. Description The MDVS TM system consists of an exhaust fan, the BESB Box Ventilator, the MEC18 Mechanical Exhaust Control, XTP pressure transducer and a VFD-Variable Frequency Drive (3-phase ventilators only). The MEC18 maintains a constant pressure for the dryers by modulating the speed of the BESB Box Ventilator. The MDVS TM system is supplied as a complete package with ventilator(s), control(s), pressure sensor, duct probe and adapters for mounting on a duct or a wall. Sizes The system is available in multiple sizes as shown on the following page. Listings ETL-listed to UL705 for Power Ventilators with special consideration given to the transport of lint-laden air. CSI Specifications CSI Model Specifications are available from ENERVEX and via the internet at us.exhausto.com. The document number is: Operation The pressure set-point must be programmed manually via the potentiometer on the MEC18 control board. Other parameters, such as optional post purge and manual/ automatic reset, may be set with the dipswitches on the control board. The clothes dryers are not interlocked with the MEC18. When one or more clothes dryers are in operation, the control increases the speed of the ventilator to maintain the pressure set-point. When a clothes dryer shuts down, the MEC18 reduces the ventilator speed to maintain the setpoint. This sequence is repeated every time clothes dryer operation is initiated. When no dryers are in operation, the ventilator runs at an idle speed to maintain the pressure set-point. If proper exhaust cannot be maintained because of mechanical or electrical failure, the control will go into alarm mode and run the ventilator at 100% speed. If the ventilator experiences mechanical or electrical failure, the MEC18 will send and alarm signal to the building management system. This will not interrupt dryer operation because they are not interlocked with the control.

2 Submittal Data MDVS MEC18 TP DUCT PROBE ABB Max. RPM MEC18 ENERVEX Inc Bluegrass Lakes Pkwy. Alpharetta, GA P: F: T:

3 Product Information Box Ventilator BESB Description The BESB Box Ventilator is a high-efficiency ventilator with a backward curved centrifugal impeller. The BESB is completely insulated to reduce noise and condensation. The BESB is used in both intake and exhaust applications The fan is designed to exhaust lint-laden air from single or multiple type I and type II residential and commercial clothes dryers, exhaust commerical hoods, or to provide make-up air for laundry or mechanical rooms. The BESB Box Ventilator is a component in the MCAS Modulating Combustion Air System and MDVS Mechanical Dryer Venting System. Material The ventilator housing is galvanized steel, while the impeller is cast aluminum. The design is Type B, Spark Resistant Construction. A service door is provided to allow easy access to the motor and impeller. Impeller is cast aluminum and balanced with permanently attached lead balancing weights. Motor The BESB is equipped with an energy-efficient, totally enclosed, variable speed motor (TEFC). Commercial grade, 1 or 3-phase motor. Class A insulated, IP54 Protection Class. Sealed ball bearings. Thermal overload protection. Standard Equipment Slip connections with silicone seals. Junction Box Accessories EBC 12 Modulating Fan Control EBC 14 Pressure Control MEC 18 Exhaust Control EBC 30 Modulating Pressure Control Variable Frequency Drive, VFD Flexible connections, FLF Proven Draft Switch, PDS Listings UL705, Standard for Power Ventilators with special consideration for venting lint-laden air from single or multiple dryers and CSA 22.2 No. 113, Standard for Fans and Ventilators. Component in an ETL Listed MCAS System Component in an ETL Listed MDVS System CE compliant Manufactured at ISO9001 certified plant Complies with and meets Type B, Spark Resistant Construction per AMCA standard classifications of Spark Resistant Construction. Warranty 2 year factory warranty Specifications are subject to change without notice.

4 Product Information Specifications Model BESB 250 BESB 315 BESB 400 BESB 500 Fan Type Motor Type Capacity Centrifugal Impeller (B-Wheel) TEFC Voltage V AC 1x120 3 x /3x Amperage Amps / / /4.1 Motor Output HP kw RPM Weight lbs Duct Connection kg E in mm Dimensions A in mm B in mm C in mm D in mm G in mm H in mm J in mm K in mm L in mm M in mm Sound Diagrams Model Lw db (measured in accordance with ISO 3744) Lp db 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz (A) BESB BESB BESB BESB ENERVEX Inc Bluegrass Lakes Pkwy. Alpharetta, GA P: F: T: info@enervex.com

5 Product Information Mechanical Exhaust Control MEC 18 Use The MEC 18 is a fan control used to monitor pressure in single or multi-story building exhaust applications. The control modulates the fan speed to maintain proper and constant pressure in the exhaust system. The MEC 18 is used with models EFV, BESF and BESB. The MEC 18 is for indoor installations only. Typical uses include: clothes dryer venting, bathroom and kitchen exhaust and other building venting applications. Description The MEC 18 monitors pressure in an exhaust duct via a XTP2 Sensor. The XTP2 constantly senses the pressure in the duct and as the pressure varies, the control adjusts the speed of the fan to maintain the pressure set-point. The MEC 18 operates a single phase fan using a VAC signal. The control sends a 0-10 VDC signal to a Variable Frequency Drive to operate a 3- phase fan. When the system is energized, the fan begins to run at full speed. Once the pressure setpoint is reached in the duct, the control adjusts the fan speed to maintain proper pressure. The control contains an optional integrated safety system that shuts down the appliance(s) in the event of a mechanical or electrical fan failure. For multiple appliance interlock one or more ES12 controls may be required. The control has fast reaction times (max. 20 seconds) and a very stable control signal assuring accurate fan operation. Material Enclosure is made of polycarbonate and is NEMA 4x rated. Standard Equipment MEC 18 Control Box XTP2 Sensor Stack Probe and Silicone Tubing XTP2 Sensor MEC 18 Control Box Listings ETL listed to UL508 and CSA C22.2 No ; Standard for Industrial Control Equipment CE Compliant Manufactured at ISO9001 certified plant. Warranty 2-year factory warranty Silicone Tubing Chimney Probe Specifications are subject to change without notice.

6 Product Information Specifications MEC 18 Control Power supply V 1x120VAC Amperage A 6.3 Operating temperature F/ C -4 to 122 / -20 to 50 Range of operation inwc/pa / Tolerance inwc/pa 0.01 / 3 +/-10% Output Current ma max. 10 Max. Load 120 VAC / 8A Real-time PID Control Method Infinitely variable Real-time PID Signal Stability +/- 0.5% Ramp Up/Down Time Seconds max 20 Output VAC VDC 0-10 Dimensions A in/mm 7.17 / 182 B in/mm 7.09 / 180 C in/mm 4.37 / 111 Weight lbs/kg 3.0 / 1.5 EMC standard Emission EN Immunity EN XTP2 Sensor Power supply VDC Amperage ma <20 Output VDC 0-10 Operating temperature F/ C 0 to 160 / -18 to 71 Accuracy +/- 0.08% Dimensions D in/mm 3.70 / 94 E in/mm 5.12 / 130 F in/mm 6.18 / 157 G in/mm 3.13 / 80 Weight lbs/kg.6 /.3 Chimney Probe Dimensions H in/mm 4.25 / 108 I in/mm 3.50 / 89 MEC MEC ENERVEX Inc Bluegrass Lakes Pkwy. Alpharetta, GA P: F: T: info@enervex.com

MEC 18 Mechanical Exhaust Control

MEC 18 Mechanical Exhaust Control Installation & Operating Manual MEC 18 Mechanical Exhaust Control USA CAN Product Information... Chapters 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

EBC 12 Modulating Fan Control

EBC 12 Modulating Fan Control Installation & Operating Manual EBC 12 Modulating Fan Control USA CAN Product Information... Chapters 1+2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

ADC150 Automatic Draft Control

ADC150 Automatic Draft Control Installation & Operating Manual ADC150 Automatic Draft Control USA CAN Product Information... Chapters 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4 Installation & Operating Manual BESB Box Ventilator USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

ENERVEX ADC100 DRAFT CONTROL

ENERVEX ADC100 DRAFT CONTROL ENERVEX ADC100 DRAFT CONTROL 3916067 04.16 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238 F: 770.587.4731

More information

EBC 10 Fan Control USA CAN. Product Information. ... Chapter 1+2. Mechanical Installation. ... Chapter 3. Electrical Installation. ...

EBC 10 Fan Control USA CAN. Product Information. ... Chapter 1+2. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Installation & Operating Manual EBC 10 Fan Control USA CAN Product Information... Chapter 1+2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration... Chapter

More information

ENERVEX RSV CHIMNEY FAN

ENERVEX RSV CHIMNEY FAN ENERVEX RSV 200-450 CHIMNEY FAN 3000775 06.16 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238 F: 770.587.4731

More information

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer: Installation & Operating Manual RSV Chimney Fan USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration... Chapter

More information

EXHAUSTO Inc in North America In Atlanta since ,000 sq.ft. office and warehouse 86 authorized sales and service offices in USA and Canada.

EXHAUSTO Inc in North America In Atlanta since ,000 sq.ft. office and warehouse 86 authorized sales and service offices in USA and Canada. EXHAUSTO Inc in North America In Atlanta since 1990 25,000 sq.ft. office and warehouse 86 authorized sales and service offices in USA and Canada. The First Fan - 1957 The first chimney fan - a first worldwide

More information

IPVB EC inline power venter

IPVB EC inline power venter Installation and operation manual IPVB 300-500 EC inline power venter READ AND SAVE THESE INSTRUCTIONS! Product information Chapters 1 + 2 Mechanical installation Chapter 3 Electrical installation Chapter

More information

ENERVEX IPVB INLINE POWER VENTER

ENERVEX IPVB INLINE POWER VENTER ENERVEX IPVB 300-500 INLINE POWER VENTER 3002600 06.16 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! ETL514733 ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P:

More information

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2 3002239 RSIF 2014-04-04 Installation and operation manual RSIF power venter READ AND SAVE THESE INSTRUCTIONS! Product information Chapters 1 + 2 Mechanical installation Chapter 3 Electrical installation

More information

RSIB Power Venter

RSIB Power Venter Installation & Operating Manual RSIB 300-500 Power Venter USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

Designing Thoughtful Green Performance - On-Demand Venting and Exhaust Systems

Designing Thoughtful Green Performance - On-Demand Venting and Exhaust Systems Designing Thoughtful Green Performance - On-Demand Venting and Exhaust Systems 23 51 13/EXH BuyLine 8599 Chimney Automation Systems Multistory Fireplace Exhaust Systems Mechanical Dryer Venting Systems

More information

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4 Installation & Operating Manual BESF Box Ventilator USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

EFC 211 Fan Control USA CAN. ... Chapter 5. Start Up and Configuration. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

EFC 211 Fan Control USA CAN. ... Chapter 5. Start Up and Configuration. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer: Installation & Operating Manual EFC 211 Fan Control USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ... Installation & Operating Manual RSIF Power Venter USA CAN Product Information... Chapters 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration... Chapter

More information

ENERVEX GSV GREASE FAN

ENERVEX GSV GREASE FAN ENERVEX GSV 200-450 GREASE FAN 3001391 12.16 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238 F: 770.587.4731

More information

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS Installation & Operating Manual 3001806 03.02 USA CAN BESF Box Ventilator READ AND SAVE THESE INSTRUCTIONS 1200 Northmeadow Parkway, STE 180 Roswell, GA 30076 (770) 587-3238 (800) 255-2923 Fax (770) 587-4731

More information

RSIF Power Venter. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

RSIF Power Venter. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS Installation & Operating Manual 3002239 09.03 USA CAN RSIF Power Venter READ AND SAVE THESE INSTRUCTIONS 1200 Northmeadow Parkway, STE 180 Roswell, GA 30076 (770) 587-3238 (800) 255-2923 Fax (770) 587-4731

More information

RS chimney fan for gas and oil applications

RS chimney fan for gas and oil applications Installation and operation manual RS chimney fan for gas and oil applications READ AND SAVE THESE INSTRUCTIONS! Product information Chapters 1 + 2 Mechanical installation Chapter 3 Electrical installation

More information

RS Chimney Fan for Gas & Oil Applications

RS Chimney Fan for Gas & Oil Applications Installation & Operating Manual RS Chimney Fan for Gas & Oil Applications USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up

More information

RS Chimney Fan for Gas & Oil Applications

RS Chimney Fan for Gas & Oil Applications Installation & Operating Manual RS Chimney Fan for Gas & Oil Applications USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up

More information

EW 40 Wireless Fan Control

EW 40 Wireless Fan Control Installation & Operating Manual EW 40 Wireless Fan Control USA CAN Product Information... Chapters 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

ENERVEX BEF BOX VENTILATOR

ENERVEX BEF BOX VENTILATOR ENERVEX BEF 200-700 BOX VENTILATOR 3001807 07.16 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! UL File E479840 ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P:

More information

ENERVEX BEF BOX VENTILATOR

ENERVEX BEF BOX VENTILATOR ENERVEX BEF 200-700 BOX VENTILATOR 3001807 06.16 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! UL File E479840 ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P:

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information

ENERVEX MDF MODULATING DAMPER

ENERVEX MDF MODULATING DAMPER ENERVEX MDF MODULATING DAMPER 3903007 05.16 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! UL File E467733 ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238

More information

Multistory Fireplace & Exhaust System

Multistory Fireplace & Exhaust System Optimize Your Venting Designs Multistory Fireplace & Exhaust System From the leaders in venting and fireplace systems ENERVEX and Isokern Fireplaces & Chimney Systems Build the perfect fire with the perfect

More information

Technical data Chimney fans, controllers & accessories in systems for multiple heating appliances

Technical data Chimney fans, controllers & accessories in systems for multiple heating appliances Technical data Chimney fans, controllers & accessories in systems for multiple heating appliances Boiler: Project and Design Support exodraft solutions are so much more than just products and systems.

More information

RS Chimney Fan for Solid Fuel Applications

RS Chimney Fan for Solid Fuel Applications Installation & Operating Manual RS Chimney Fan for Solid Fuel Applications USA CAN Product Information... Chapters 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start

More information

RSHT Volko Supply USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual

RSHT Volko Supply USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual RSHT009-016 Installation and operation manual Volko Supply www.chimneyfansource.com 800 685 8263 READ AND SAVE THESE INSTRUCTIONS! Product information Chapters 1 + 2 Mechanical installation Chapter 3 Electrical

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

ENERVEX VHX VORTEX HEAT RECOVERY CENTER

ENERVEX VHX VORTEX HEAT RECOVERY CENTER ENERVEX VORTEX HEAT RECOVERY CENTER 3002603 06.16 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238 F:

More information

NEW. Demand-Controlled Exhaust Systems for Commercial and Industrial Bakeries. For Commercial and industrial Baking Oven Systems

NEW. Demand-Controlled Exhaust Systems for Commercial and Industrial Bakeries. For Commercial and industrial Baking Oven Systems Demand-Controlled Exhaust Systems for Commercial and Industrial Bakeries TRUE GREEN SOLUTIONS NEW For Commercial and industrial Baking Oven Systems Variable Speed and Direct Drive Natural Gas, LP Gas and

More information

Indirect Gas-Fired Make-Up Air

Indirect Gas-Fired Make-Up Air Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041 Product Features Model IG Indirect Gas-Fired Make-Up

More information

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004) High Plume Blowers Suggested Specification Section 15500 (Master Format 1996) Suggested Specification Section 23 38 16 (Master Format 2004) PART 1 GENERAL 1.01 WORK INCLUDED High Plume Laboratory Exhaust

More information

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN Installation & Operating Manual 3000270 10.01 USA CAN RS Chimney Fan For Gas & Oil Applications 1200 Northmeadow Parkway, STE 180 Roswell, GA 30076 (770) 587-3238 (800) 255-2923 Fax (770) 587-4731 info@exhausto.com

More information

ENERVEX TDF POWER VENTER

ENERVEX TDF POWER VENTER ENERVEX TDF 160-760 POWER VENTER Installation & Operating Manual 3916074 07.16 READ AND SAVE THESE INSTRUCTIONS! UL File E479840 ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238

More information

Revitalize Building Mechanical Systems (4619)

Revitalize Building Mechanical Systems (4619) SECTION 235216 FIRE-TUBE CONDENSING BOILERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty MODEL OVERVIEW The POWERVENT (PV) series of direct drive centrifugal in-line duct ventilation fans consists of twelve model sizes 4, 5, 6, 8, 10 and 12.4 respectively. All models are designed for direct

More information

90% Efficiency without Boiler Replacement TRUE GREEN SOLUTIONS NEW. Patent Pending. EcoFlex 90 + System Modulating Fan-Powered Economizer

90% Efficiency without Boiler Replacement TRUE GREEN SOLUTIONS NEW. Patent Pending. EcoFlex 90 + System Modulating Fan-Powered Economizer without Boiler Replacement TRUE GREEN SOLUTIONS NEW Patent Pending EcoFlex + System Modulating Fan-Powered Economizer EcoFlex + System Because They Are Your Btus EcoFlex + System - a packaged modulating

More information

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

EBC20. Instructions for fitting, installation and operation. Read and save these instructions! EBC20 UK Instructions for fitting, installation and operation Read and save these instructions! 2 3002878 EBC20 UK 290415 1. Product information............................................... 4 1.1 Delivery.............................................................

More information

MFD Mechanical Fireplace Damper

MFD Mechanical Fireplace Damper Installation & Operating Manual MFD Mechanical Fireplace Damper USA CAN Product Information... Chapter 1+2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

28 1/2"* 72.4 cm. (*28 1/2 " to include hinges.) 41 3/4" 106 cm. 27" 68.6 cm. 28 1/2"* 72.4 cm. (includes hinges.) 28 1/2"* 41 3/4" 106 cm

28 1/2* 72.4 cm. (*28 1/2  to include hinges.) 41 3/4 106 cm. 27 68.6 cm. 28 1/2* 72.4 cm. (includes hinges.) 28 1/2* 41 3/4 106 cm Commercial Single Load Dryers 28 1/2"* 72.4 cm PRODUCT DIMENSIONS (*28 1/2 " to include hinges.) 28 1/2"* 72.4 cm (*28 1/2 " to include hinges.) Models MDE/MDG21PD MDE/MDG21PS MDE/MDG21PR MDE/MDG21PN 43

More information

RS Chimney Fan for Solid Fuel Applications

RS Chimney Fan for Solid Fuel Applications Installation & Operating Manual RS Chimney Fan for Solid Fuel Applications USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up

More information

Direct Gas-Fired Make-Up Air

Direct Gas-Fired Make-Up Air Direct Gas-Fired Make-Up Air Model TSU Heavy Duty, High Airflow Applications Manufacturing and Industrial Facilities Up to 64,000 cfm August 2012 Products Model TSU Direct Gas-Fired Make-Up Air Unit The

More information

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation Industrial Space Heating Direct Gas-Fired Heating Greenheat 00% Outdoor Air Greenheat 50/50 Recirculation 80/0 Recirculation March 008 Product Overview Industrial Space Heating Greenheck s space heating

More information

ENERVEX MFD MECHANICAL FIREPLACE DAMPER

ENERVEX MFD MECHANICAL FIREPLACE DAMPER ENERVEX MFD MECHANICAL FIREPLACE DAMPER Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! UL File E467733 ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL NVC ULTRA LOW NOx GAS BURNERS SUB 9 PPM NOx THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone: 620-421-0480,

More information

EBC12-EU-01. Product Instruction fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

EBC12-EU-01. Product Instruction fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov 3001434-2006-09-01.fm Product Instruction GB EBC12-EU-01 EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov Tel. +45 65 66 12 34 Fax +45 65 66 11 10 exhausto@exhausto.dk www.exhausto.dk 3001434-2006-09-01.fm

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

Precise Temperature Control; Compact Footprint

Precise Temperature Control; Compact Footprint Precise Temperature Control; Compact Footprint The Conair EP1 Series Portable Chillers are designed for 1 to 3 ton applications. Available as air-cooled or water-cooled, with pump sizes from 1/4 to 3 Hp

More information

Multistory Fireplace & Exhaust System

Multistory Fireplace & Exhaust System Optimize Your Venting Designs Multistory Fireplace & Exhaust System From the leaders in venting and fireplace systems EXHAUSTO and Isokern Fireplaces & Chimney Systems Build the perfect fire with the perfect

More information

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

A. General: Refer to paragraph entitled SUBMITTAL in Section Include the following data: SECTION 15860 - FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR MECHANICAL

More information

External Roof-mounted Power Vent System

External Roof-mounted Power Vent System External Roof-mounted Power Vent System Installation, Operation and Owner s Manual Please read this manual thoroughly before beginning the installation. It has information which is important for safe installation

More information

on-demand Minimizing Energy Loss through order to meet Sustainable Design Standards

on-demand Minimizing Energy Loss through order to meet Sustainable Design Standards Venting- on-demand Minimizing Energy Loss through the Exhaust Ventilation Systems in order to meet Sustainable Design Standards Approach Controlled Venting Versus Natural Venting Controlled Air Supply

More information

A TRUE GAME CHANGER - The Vortex Heat Recovery Center CONDENSING EFFICIENCIES FOR TRADITIONAL BOILERS & HEATERS

A TRUE GAME CHANGER - The Vortex Heat Recovery Center CONDENSING EFFICIENCIES FOR TRADITIONAL BOILERS & HEATERS A TRUE GAME CHANGER - The Vortex Heat Recovery Center CONDENSING EFFICIENCIES FOR TRADITIONAL BOILERS & HEATERS Flexibility and Performance - Unlike any other Heat Recovery System FEATURES Exceptional

More information

Electric Coils. Blower Coils. Product Information

Electric Coils. Blower Coils. Product Information Product Information General Information Electric heat coils are an available accessory for use with Price blower coil units. The electric heating coils have been specific ally designed to suit Price blower

More information

ENERVEX GSV GREASE FAN

ENERVEX GSV GREASE FAN ENERVEX GSV 009-016 GREASE FAN 3001361 08.17 Installation & Operating Manual READ AND SAVE THESE INSTRUCTIONS! ENERVEX Inc. 1685 Bluegrass Lakes Parkway Alpharetta, GA 30004 USA P: 770.587.3238 F: 770.587.4731

More information

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS MVB, TYPE WH - MODELS 503A-2003A SUGGESTED SPECIFICATIONS Catalog No.: 3500.952C Effective: 06-25-15 Replaces: 12-22-09 DIVISION 23 34 36.29 COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

More information

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps Note: The A/E must choose all design values in brackets below before using in project specifications 1 General 1.1 Provide UL listed and FM approved fire pump complete with pump, driver, controller and

More information

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design Fan motor (PSC or ECM). UL Listed 1 insulation conforms to UL Test 181 and NFPA 90A. Plenum air filter rack. (Filter Optional) Casing has

More information

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s) Furnish and install as shown on AERCO International plans and operation and maintenance manuals, with all applicable codes and authorities having local, state and federal jurisdiction, Benchmark Series

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 504A-2004A SUGGESTED SPECIFICATIONS Catalog No.: 2000.933C Effective: 06-25-15 Replaces: 12-21-09 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

Technical data. Chimney fans, controls and accessories for gas fireplaces, stoves and single non-modulating gas boilers G A S

Technical data. Chimney fans, controls and accessories for gas fireplaces, stoves and single non-modulating gas boilers G A S Technical data Chimney fans, controls and accessories for gas fireplaces, stoves and single non-modulating gas boilers G A S 2 Systems for gas fireplaces and gas stoves The exodraft chimney fan systems

More information

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT Fans, Heaters & Controls 1 GRAIN CONDITIONING EQUIPMENT SIOUX STEEL COMPANY Innovative Solutions Manufactured By A Family-Owned Company With A ENGINEERING

More information

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS XTHERM, TYPE WH - MODELS 1005A- 2005A Catalog No.: 3500.801 Effective: 11-15-14 Replaces: NEW PART 1 - GENERAL 1.1 SUMMARY DIVISION 23 34 36.29 COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

More information

5 year fan housing and motor warranty

5 year fan housing and motor warranty MODEL SWF SIDEWALL CENTRIFUGAL FAN MODEL FEATURES Exhaust air up to 416 CFM with static pressure capabilities to 1.5 w.g. Galvanized steel casing with black backed enamel coating Pre-wired junction box

More information

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages Point-of-Use Tankless Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages Features Heavy Duty Construction Reliability Constructed with high grade materials to ensure long operating

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 233423 - HVAC POWER VENTILATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 PERFORMANCE REQUIREMENTS A. Operating

More information

Modular Heating & Ventilating Unit Model IGX-HV

Modular Heating & Ventilating Unit Model IGX-HV Modular Heating & Ventilating Unit Model IGX-HV Indirect Gas-Fired Heating Evaporative Chilled Water DX Cooling October 2008 Product Features Model IGX-HV Indirect Gas-Fired Heating and Ventilating Unit

More information

Submittal Data Performance Data Electrical Data

Submittal Data Performance Data Electrical Data ERMS Series Submittal Data Submittal Data Unit Designation: Job name: Architect: Engineer: Contractor: Performance Data Revision: 07/01/11 Cooling Capacity: EER: Heating Capacity: COP: Ambient Air Temp:

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 230593 - TESTING, ADJUSTING, AND BALANCING FOR HVAC PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Balancing Air Systems: a. Constant-volume air systems. b. Variable-air-volume systems. 2.

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 503A-2003A SUGGESTED SPECIFICATIONS Catalog No.: 2000.932C Effective: 04-01-14 Replaces: 07-15-13 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS XPAK FT TYPE H - MODELS 088AR-398A SUGGESTED SPECIFICATIONS Catalog No.: 2100.91 Effective: 05/01/15 Replaces: new DIVISION 23 52 33.13 WALL-HUNG STAINLESS STEEL HEATING BOILERS PART 1 - GENERAL 1.1 SUMMARY

More information

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for: Date: 05/21/2001 Time: 02:57:44 PM Job Name: EarthWise VAV Terminal Units Full Spec Location: AnyTown, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SINGLE & DUAL DUCT UNIT

More information

FT900BD FLIGHT-TYPE DISHWASHER

FT900BD FLIGHT-TYPE DISHWASHER Item # Quantity C.S.I. Section 11400 FT900BD FLIGHT-TYPE DISHWASHER STANDARD FEATURES Opti-RinSe system Water usage 120 gph @ 20 psi Microprocessor controls Low temperature alert Blower dryer with 2 H.P.

More information

SENTRA Series Water Unit

SENTRA Series Water Unit SENTRA Series Water Unit Standard Unit: F to 0 F Process Fluid Temperatures* Optional High Temperature Configuration to 0 F Direct Injection Cooling 0 to kw Heaters to 7. HP Centrifugal Pumps (0-00 GPM)

More information

AC Backward Curved Motorized Impellers

AC Backward Curved Motorized Impellers AC Backward Curved Motorized Impellers 135 ebm's Backward Curved Motorized Impellers save space and outperform conventional fans and blowers These backward curved motorized impellers provide efficient

More information

C1210ES Tankless Water Heater

C1210ES Tankless Water Heater Engineering Submittal Sheet Dimensions and Connections B C D C Combustion air inlet Exhaust outlet Optional combustion air inlet Top view Top view A E Hot water outlet Cold water inlet F H J C I K G Front

More information

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T-TWIN is characterized by having no additional moisture

More information

A. Product Data: Include rated capacities, furnished specialties and accessories.

A. Product Data: Include rated capacities, furnished specialties and accessories. BASE BID: SECTION 15542 FUEL-FIRED RADIANT HEATERS PART 1 - GENERAL 1.1 SUMMARY A. Furnish and install a Co-Ray-Vac Low Intensity Vented Infrared Radiant Vacuum Gas Heating System. System must be certified

More information

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER Item # Quantity C.S.I. Section 11400 FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER STANDARD FEATURES Opti-RinSe system with dual rinse Water usage 72 gph @ 20 psi Microprocessor controls Low temperature

More information

Selecting the Correct Fan

Selecting the Correct Fan Selecting the Correct Fan Ryan B. Johnson Air Purification Company Sales Engineer Member, ASHRAE Pikes Peak Chapter rjohnson@airpurificationcompany.com 1 Your Speaker circa 1998 Fan Types Applications

More information

108A OTP1800. Grid Support. General Description

108A OTP1800. Grid Support. General Description Operation Manual 108A OTP1800 ON/OFF Main Switch On/Off Alarm Switch Digital Control Module Grid Support Alarm Fuse 250 Volt 15 amp Load Outlet Sensor Input Inlet General Description This control is a

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with Puronr (R---410A) Refrigerant Sizes: 17, 20, 24, 28, 30 Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION

More information

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models) Temperature Control Units Water & Oil - 00 F Portable Chillers Air & Water-Cooled 0-70 F Central Chillers Air & Water-Cooled Packages & Modules 0-70 F Pump Tank Stations Chilled or Tower Water 00-00 gallons

More information

C1050ES Tankless Water Heater

C1050ES Tankless Water Heater Engineering Submittal Sheet Dimensions and Connections B C D C Combustion air inlet Exhaust outlet Optional combustion air inlet Top view Top view A E F Hot water outlet Cold water inlet Inlet water filter

More information

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES 60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,

More information

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER PART 1 GENERAL 1.01 RELATED DOCUMENTS A. ANSI Z21.13 American National Standard for Gas-Fired Low Pressure Steam and Hot Water Boilers B. ASME Section

More information

fans & heaters SIMPLE, ROBUST AND RELIABLE

fans & heaters SIMPLE, ROBUST AND RELIABLE FANS & HEATERS fans & heaters SIMPLE, ROBUST AND RELIABLE For over 50 years, NECO has specialized in agricultural equipment engineering and manufacturing. NECO produces market leading grain dryers and

More information

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY SECTION 22 11 23.13 DOMESTIC WATER PRESSURE BOOSTING PART 1 - GENERAL 1.1 SUMMARY A. Where utility water pressure cannot adequately meet the pressure requirements of the domestic water systems and where

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 2503-4003 SUGGESTED SPECIFICATIONS Catalog No.: 2000.934A Effective: 04-01-14 Replaces: 06-01-13 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

ONQUEST. Featuring... Condensing Water Heater. Requires no tank linings or heat exchanger linings. Requires no anodes of any type. 10- year warranty.

ONQUEST. Featuring... Condensing Water Heater. Requires no tank linings or heat exchanger linings. Requires no anodes of any type. 10- year warranty. R C ONQUEST TM Condensing Water Heater UP TO 97% THERMAL EFFICIENCY AT FULL RATE FROM 40 F TO 140 F TANK AND HEAT EXCHANGER MADE FROM AquaPLEX ENGINEERED DUPLEX STAINLESS STEEL ALLOY Featuring... SEAMLESS

More information

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh HEATERS / BOILERS GWB8-E Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 065 July 06 Supersedes September 05 AFUE up to 83.9% Heating Input 50,000 to 99,000 Btuh MODEL NUMBER IDENTIFICATION

More information

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation JAU /JCC/JVC Series Jet Fans - for car park ventilation INTRODUCTION Pacific HVAC Engineering is able to offer a complete solution in car park ventilation at a competitive price with in house developed

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION 100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest

More information