1 Air Conditioning Technical Data EEDEN AZQS-BV1
2
3 TABLE OF CONTENTS AZQS-BV1 1 Features Specifications Nominal Capacity And Nominal Input Nominal Capacity And Nominal Input Nominal Capacity And Nominal Input Nominal Capacity And Nominal Input Technical Specifications Electrical Specifications Electrical data Options Combination table Capacity tables Cooling Capacity Tables Heating Capacity Tables Capacity Correction Factor Dimensional drawings Centre of gravity Piping diagrams Wiring diagrams Wiring Diagrams - Single Phase Sound data Sound Power Spectrum Sound Pressure Spectrum - Cooling Sound Pressure Spectrum - Heating Sound Pressure Spectrum Quiet Mode Installation Installation Method Operation range Split - Sky Air AZQS-BV1 1
4 k i n - r o t o - i d l t p uz 1 Features Outdoor Unit AZQS-BV1 S U 1 V B S Q O AS Daikin outdoor units are neat, sturdy and can easily be mounted on a roof or terrace or simply placed against an outside wall Outdoor units are fitted with either a swing or scroll compressor, renowned for low noise and high energy efficiency Outdoor units for pair application Seasonal efficiency, optimized for all seasons. Seasonal efficiency gives an indication on how efficient an air conditioner operates over an entire heating or cooling season. 1 Inverter Auto coolingheating changeover 2 Split - Sky Air AZQS-BV1
5 2 Specifications Outdoor Unit AZQS-BV1 2-1 Nominal Capacity And Nominal Input *ACQ71C/AZQS71BV1 ACQ100C/AZQS100BV1 ACQ125C/AZQS125BV1 Cooling capacity Nom. kw Heating capacity Nom. kw Seasonal efficiency Cooling Energy label B B - (according to Pdesign kw EN14825) SEER Annual energy consumption kwh Heating (Average Energy label A A - climate) Pdesign kw SCOP Annual energy consumption kwh 2,332 2,800 - Nominal efficiency EER (cooling at 35 /27 COP nominal load, heating Annual energy consumption kwh 1,027 1,480 2,010 at 7 /20 nominal load) Energy label Cooling A A B Heating A A B 3 2 Notes (1) EER/COP according to Eurovent Nominal Capacity And Nominal Input ABQ71B/AZQS71BV1 Cooling capacity Nom. kw 6.8 (3) Heating capacity Nom. kw 7.5 (4) Seasonal efficiency Cooling Energy label B (according to Pdesign kw 6.80 EN14825) SEER 4.65 Annual energy consumption kwh 512 Heating (Average Energy label A climate) Pdesign kw 6.33 SCOP 3.41 Annual energy consumption kwh 2,599 Nominal efficiency EER 3.01 (cooling at 35 /27 COP 3.61 nominal load, heating Annual energy consumption kwh 1,130 at 7 /20 nominal load) Energy label Cooling B Heating A Notes (1) EER/COP according to Eurovent Nominal Capacity And Nominal Input ABQ125A/AZQS125BV1 ABQ140A/AZQS140BV1 Cooling capacity Nom. kw Heating capacity Nom. kw Seasonal efficiency Cooling Energy label - (according to Pdesign kw - EN14825) SEER - Annual energy consumption kwh - Heating (Average Energy label - climate) Pdesign kw - SCOP - Annual energy consumption kwh - Split - Sky Air AZQS-BV1 3
6 2 Specifications Outdoor Unit AZQS-BV Nominal Capacity And Nominal Input ABQ125A/AZQS125BV1 ABQ140A/AZQS140BV1 Nominal efficiency (cooling at 35 /27 nominal load, heating at 7 /20 nominal load) Notes EER COP 3.41 Annual energy consumption kwh 2,079 2,159 Energy label Cooling C B Heating B (1) EER/COP according to Eurovent Nominal Capacity And Nominal Input AHQ71C/AZQS71BV1 AHQ100C/AZQS100BV1 AHQ125C/AZQS125BV1 AHQ140C/AZQS140BV1 Cooling capacity Nom. kw Heating capacity Nom. kw Seasonal efficiency Cooling Energy label B - (according to Pdesign kw EN14825) SEER Annual energy consumption kwh Heating (Average Energy label A - climate) Pdesign kw SCOP Annual energy consumption kwh 2,332 2,800 - Nominal efficiency EER (cooling at 35 /27 COP nominal load, heating Annual energy consumption kwh 1,120 1,810 2,300 2,159 at 7 /20 nominal load) Energy label Cooling B D B Heating D B A B Notes (1) EER/COP according to Eurovent Technical Specifications AZQS71BV1 AZQS100BV1 AZQS125BV1 AZQS140BV1 Capacity control Method Inverter controlled Casing Colour - Ivory white Material - Painted galvanized steel plate Dimensions Unit Height mm ,430 Width mm Depth mm 320 Packed unit Height mm 900 1,170 1,610 Width mm 980 1,015 Depth mm Weight Unit kg Packed unit kg Heat exchanger Length mm Rows Quantity 2 - Fin pitch mm Passes Quantity 8 - Face area m² Stages Quantity 34 - Empty tubeplate Quantity 0 - hole Tube type Hi-XSS (8) - Fin Type WF fin Treatment Anti-corrosion treatment (PE) 4 Split - Sky Air AZQS-BV1
7 2 Specifications Outdoor Unit AZQS-BV1 2-5 Technical Specifications AZQS71BV1 AZQS100BV1 AZQS125BV1 AZQS140BV1 Compressor Quantity 1 Model 2YC63DXD - Type Hermetically sealed swing compressor Output W 1, Starting method Inverter driven - Fan Type Propeller fan Discharge direction Horizontal Quantity 1 2 Air flow rate Cooling Nom. m³/min Super m³/min - low cfm - Heating Nom. m³/min Super m³/min - low cfm - Fan motor Quantity 1 2 Model KFD A Brushless DC motor Output W Drive Direct drive Speed Steps 8 - Cooling Nom. rpm Super low rpm - Heating Nom. rpm Super low rpm - Sound power level Cooling Nom. dba Sound pressure level Cooling Nom. dba Silent operation dba 43 - Heating Nom. dba Night quiet mode Level 1 dba - 49 Operation range Cooling Ambien Min. CDB -5.0 t Max. CDB 46.0 Heating Ambien Min. CWB t Max. CWB 15.5 Refrigerant Type R-410A Charge kg Control Expansion valve (electronic type) GWP 1,975 Circuits Quantity 1 Refrigerant oil Type FVC50K Charged volume l Split - Sky Air AZQS-BV1 5
8 2 Specifications Outdoor Unit AZQS-BV Technical Specifications AZQS71BV1 AZQS100BV1 AZQS125BV1 AZQS140BV1 Piping connections Liquid Quantity 1 Type Flare connection OD mm 9.52 Gas Quantity 1 Type Flare connection OD mm 15.9 Drain Quantity 3 5 Type Hole ID mm - OD mm 26 Piping length OU - IU Min. m 5 Max. m System Equival ent m Chargel ess m 30 Additional refrigerant charge kg/m See installation manual Level difference IU - OU Max. m IU - IU Max. m Heat insulation Both liquid and gas pipes Defrost method Pressure equalising Reversed cycle Defrost control Sensor for outdoor heat exchanger temperature Safety devices Item 01 High pressure switch 02 Fan motor thermal protection 03 Fuse 2-6 Electrical Specifications AZQS71BV1 AZQS100BV1 AZQS125BV1 AZQS140BV1 Power supply Name V1 Phase 1~ Frequency Hz 50 Voltage V Voltage range Min. % -10 Max. % 10 Current Nominal running Cooling A current (RLA) Zmax List Complies to EN Complies to EN Recommended fuses A Current - 50Hz Maximum fuse amps (MFA) A 20 - Current - 60Hz Maximum fuse amps (MFA) A - Wiring connections For power supply Remark - See installation manual outdoor unit For connection with Remark - See installation manual outdoor unit indoor Power supply intake Outdoor unit only Notes (1) See separate drawings for electrical data (2) Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC : European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current \>16A and 75A per phase (3) PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (4) European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and 75A per phase. (5) Short-circuit power (6) RLA is based on following conditions: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB (7) MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). 6 Split - Sky Air AZQS-BV1
9 3 Electrical data 3-1 Electrical Data Outdoor Unit AZQS-BV1 3 3 Split - Sky Air AZQS-BV1 7
10 4 Options 4-1 Options Outdoor Unit AZQS-BV1 4 8 Split - Sky Air AZQS-BV1
11 5 Combination table 5-1 Combination Table Outdoor Unit AZQS-BV1 3 5 Split - Sky Air AZQS-BV1 9
12 6 Capacity tables 6-1 Cooling Capacity Tables 6 10 Split - Sky Air AZQS-BV1
13 6 Capacity tables 6-1 Cooling Capacity Tables 3 6 Split - Sky Air AZQS-BV1 11
14 6 Capacity tables 6-1 Cooling Capacity Tables 6 12 Split - Sky Air AZQS-BV1
15 6 Capacity tables 6-1 Cooling Capacity Tables 3 6 Split - Sky Air AZQS-BV1 13
16 6 Capacity tables 6-2 Heating Capacity Tables 6 14 Split - Sky Air AZQS-BV1
17 6 Capacity tables 6-2 Heating Capacity Tables 3 6 Split - Sky Air AZQS-BV1 15
18 6 Capacity tables 6-2 Heating Capacity Tables 6 16 Split - Sky Air AZQS-BV1
19 6 Capacity tables 6-2 Heating Capacity Tables 3 6 Split - Sky Air AZQS-BV1 17
20 6 Capacity tables 6-3 Capacity Correction Factor 6 18 Split - Sky Air AZQS-BV1
21 7 Dimensional drawings 7-1 Dimensional Drawings 3 7 Split - Sky Air AZQS-BV1 19
22 7 Dimensional drawings 7-1 Dimensional Drawings 7 20 Split - Sky Air AZQS-BV1
23 8 Centre of gravity 8-1 Centre of Gravity Outdoor Unit AZQS-BV1 3 8 Split - Sky Air AZQS-BV1 21
24 8 Centre of gravity 8-1 Centre of Gravity Outdoor Unit AZQS-BV Split - Sky Air AZQS-BV1
25 9 Piping diagrams 9-1 Piping Diagrams Outdoor Unit AZQS-BV1 3 9 Split - Sky Air AZQS-BV1 23
26 10 Wiring diagrams 10-1 Wiring Diagrams - Single Phase Split - Sky Air AZQS-BV1
27 10 Wiring diagrams 10-1 Wiring Diagrams - Single Phase 3 10 Split - Sky Air AZQS-BV1 25
28 11 Sound data 11-1 Sound Power Spectrum Split - Sky Air AZQS-BV1
29 11 Sound data 11-2 Sound Pressure Spectrum - Cooling 3 11 Split - Sky Air AZQS-BV1 27
30 11 Sound data 11-3 Sound Pressure Spectrum - Heating Split - Sky Air AZQS-BV1
31 11 Sound data 11-4 Sound Pressure Spectrum Quiet Mode 3 11 Split - Sky Air AZQS-BV1 29
32 12 Installation 12-1 Installation Method Outdoor Unit AZQS-BV Split - Sky Air AZQS-BV1
33 12 Installation 12-1 Installation Method Outdoor Unit AZQS-BV Split - Sky Air AZQS-BV1 31
34 13 Operation range 13-1 Operation Range Outdoor Unit AZQS-BV1 AZQS-BV1 (Cooling) 13 Outdoor temp. ( CDB) Operation range Allowable range of operation (pull-down) Outdoor temp. ( CWB) Allowable range of operation (warming-up) (Heating) Operation range Indoor temp. ( CWB) Indoor temp. ( CDB) Notes: 1 Depending on operation and installation conditions, the indoor unit can change over to freeze-up operation (indoor de-icing). 2 To reduce the freeze-up operation (indoor de-icing) frequency, it is recommended to install the outdoor unit in a location not exposed to wind. 3 In case of high humidity conditions (>92%) in this operation area, an RZQG model should be used instead of an RZQSG model. This to avoid freeze-up of the outdoor unit. 3D Split - Sky Air AZQS-BV1
35 Daikin Europe N.V. participates in the Eurovent Certification programme for Liquid Chilling Packages (LCP), Air handling units (AHU) and Fan coil units (FCU), Check ongoing validity of certificate online: or using: The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V. BARCODE Daikin products are distributed by: Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium BE RPR Oostende EEDEN /13 Copyright Daikin The present publication supersedes EEDEN13-131
Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1
Air Conditioning Technical Data EEDEN-00 RZQSG-L(/8)V Outdoor Unit RZQSG-L(/8)V TABLE OF CONTENTS RZQSG-L(/8)V Features............................................................. 2 2 Specifications.......................................................
More informationAir Conditioning. Technical Data EEDEN RZQG-L8/7V1
Air Conditioning Technical Data EEDEN14-100 RZQG-L8/7V1 Outdoor Unit RZQG-L8/7V1 TABLE OF CONTENTS RZQG-L8/7V1 1 Features............................................................. 2 2 Specifications.......................................................
More informationAir Conditioning. Technical Data EEDEN RZQSG-L(8)Y1
Air Conditioning Technical Data EEDEN3-00 RZQSG-L(8)Y Outdoor Unit RZQSG-L(8)Y TABLE OF CONTENTS RZQSG-L(8)Y Features............................................................. 2 2 Specifications.......................................................
More informationAir Conditioning. Technical Data EEDEN RXS-F8
Air Conditioning Technical Data EEDEN15-100 RXS-F8 Outdoor Unit RXS-F8 TABLE OF CONTENTS RXS-F8 1 Features............................................................. 2 2 Specifications.......................................................
More informationAir Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C
Air Conditioning Technical Data Pair, Twin, triple, double twin EEDEN-00 RZQ-C TABLE OF CONTENTS RZQ-C Features............................................................. 2 2 Specifications.......................................................
More informationAir Conditioning. Technical Data. Multi model application EEDEN MXS-E
Air Conditioning Technical Data Multi model application EEDEN1-100 MXS-E TABLE OF CONTENTS MXS-E 1 Features............................................................. 2 2 Specifications.......................................................
More informationAir Conditioners Technical Data
Air Conditioners Technical Data O u t d o o r u n i t - m u l t i m o d e l E E D E N 2-0 0 MXS-K TABLE OF CONTENTS MXS-K Features............................................................. 2 2 Specifications.......................................................
More informationHeating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1
Heating Technical Data Daikin Altherma low temperature monobloc EEDEN3-725 EBLQ-BB6W Monobloc with bottom plate heater EBLQ-BB6W TABLE OF CONTENTS EBLQ-BB6W Features.............................................................
More informationHeating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3
Heating Technical Data Daikin Altherma low temperature monobloc EEDEN3-725 EDHQ-BB6V3 Monobloc without bottom plate heater EDHQ-BB6V3 TABLE OF CONTENTS EDHQ-BB6V3 Features.............................................................
More informationHeating. Technical Data EEDEN ERRQ-AY1
Heating Technical Data EEDEN3-726 ERRQ-AY Daikin Altherma high temperature split ERRQ-AY TABLE OF CONTENTS ERRQ-AY Features............................................................. 2 2 Specifications.......................................................
More informationAir Conditioners Technical Data
Air Conditioners Technical Data F l o o r s t a n d i n g u n i t E E D E N 2-0 0 FVQ-C Indoor Unit Floor standing unit FVQ-C TABLE OF CONTENTS FVQ-C Features.............................................................
More informationAir Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9)
Air Conditioning Technical Data Flexi type unit EEDEN14-100 FLXS-B(9) Indoor Unit FLXS-B(9) TABLE OF CONTENTS FLXS-B(9) 1 Features............................................................. 2 2 Specifications.......................................................
More informationAir Conditioning. Technical Data. Concealed ceiling unit EEDEN FDXM-F
Air Conditioning Technical Data Concealed ceiling unit EEDEN16-100 FDXM-F Indoor Unit FDXM-F TABLE OF CONTENTS FDXM-F 1 Features............................................................. 2 2 Specifications.......................................................
More informationAir Conditioners Technical Data
Air Conditioners Technical Data W a l l m o u n t e d u n i t E E D E N 2-0 0 CTXS-K Indoor Unit Wall mounted unit CTXS-K TABLE OF CONTENTS CTXS-K Features.............................................................
More informationAir Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C
Air Conditioning Technical Data Concealed ceiling unit with high ESP EEDEN15-100 FDQ-C TABLE OF CONTENTS FDQ-C 1 Features............................................................. 2 2 Specifications.......................................................
More informationAir Conditioners Technical Data
Air Conditioners Technical Data W a l l m o u n t e d u n i t E E D E N 2-0 0 4 FTXN-L Indoor Unit Wall mounted unit FTXN-L TABLE OF CONTENTS FTXN-L Features.............................................................
More informationAir Conditioning. Technical Data. Wall mounted unit EEDEN FTXG-JW
Air Conditioning Technical Data Wall mounted unit EEDEN2-00 FTXG-JW Indoor Unit Wall mounted unit FTXG-JW TABLE OF CONTENTS FTXG-JW Features.............................................................
More informationAir Conditioning. Technical Data. 4-way blow ceiling mounted cassette EEDEN ACQ-C
Air Conditioning Technical Data 4-way blow ceiling mounted cassette EEDEN14-131 ACQ-C Indoor Unit ACQ-C TABLE OF CONTENTS ACQ-C 1 Features.............................................................
More informationAir Conditioning Technical Data FAA-A > FAA71AUVEB > FAA100AUVEB
Air Conditioning Technical Data FAA-A > FAA71AUVEB > FAA0AUVEB Indoor Unit FAA-A TABLE OF CONTENTS FAA-A 1 Features............................................................. 2 2 Specifications.......................................................
More informationAir Conditioners. Technical Data RZQG-L
Air Conditioners Technical Data O u t d o o r u n i t s o p t i m i z e d f o r s e a s o n a l e f f i c i e n c y w w w. d a i k i n. e u RZQG-L Air Conditioners Technical Data O u t d o o r u n i t
More informationAir Conditioners Technical Data
Air Conditioners Technical Data I n d o o r u n i t E E D E N - 3 ABQ-A Indoor Unit Concealed ceiling unit ABQ-A TABLE OF CONTENTS ABQ-A Features.............................................................
More informationAir Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B
Air Conditioning Technical Data Concealed ceiling unit with high ESP EEDEN15-100 FDQ-B Indoor Unit FDQ-B TABLE OF CONTENTS FDQ-B 1 Features.............................................................
More informationDesigned. colder climates. for AIR TO AIR HEAT PUMPS FTXS K FTXS-20-25K
Designed colder climates for AIR TO AIR HEAT PUMPS FTXS-20-25K FTXS35-42-50K Optimised heating solutions down to -25 C outdoor temperatures Prestigious design Prevents winter freezing in summer homes Whisper
More informationAir Conditioning. Technical Data. Ceiling suspended unit EEDEN AHQ-C
Air Conditioning Technical Data Ceiling suspended unit EEDEN13-131 AHQ-C Indoor Unit AHQ-C TABLE OF CONTENTS AHQ-C 1 Features............................................................. 2 2 Specifications.......................................................
More informationAir Conditioners Heating & Cooling
Air Conditioners Heating & Cooling High COP, round flow cassette Seasonal efficiency, optimized for all seasons High COP cassette ensures top performance 360 air discharge Auto-cleaning cassette Even more
More informationAir Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB
Air Conditioning Technical Data Concealed ceiling unit with high ESP EEDEN15-204 FXMQ-MB Indoor Unit FXMQ-MB TABLE OF CONTENTS FXMQ-MB 1 Features.............................................................
More informationAir Conditioning. Technical Data. Low temperature hydrobox for VRV EEDEN HXY-A
Air Conditioning Technical Data Low temperature hydrobox for VRV EEDEN3-204 HXY-A Indoor Unit Low temperature hydrobox for VRV HXY-A TABLE OF CONTENTS HXY-A Features.............................................................
More informationPure comfort & design
Pure comfort & design Pure comfort Daikin introduces > COMFORT IS KEY Nexura makes your world a comfortable one. The coolness of a summer breeze or the cosiness of an extra heat source brings a feeling
More informationAir Conditioning. Technical Data. Small concealed ceiling unit EEDEN FDBQ-B
Air Conditioning Technical Data Small concealed ceiling unit EEDEN15-100 FDBQ-B Indoor Unit FDBQ-B TABLE OF CONTENTS FDBQ-B 1 Features............................................................. 2 2
More informationAir Conditioning. Technical Data. Wall mounted unit EEDEN FTX-J3
Air Conditioning Technical Data Wall mounted unit EEDEN15-0 FTX-J3 TALE OF CONTENTS FTX-J3 1 Features............................................................. 2 2 Specifications.......................................................
More informationPure comfort & design
Pure comfort & design Pure comfort Daikin introduces > COMFORT IS KEY Nexura makes your world a comfortable one. The coolness of a summer breeze or the cosiness of an extra heat source brings a feeling
More informationHeating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping
Heating & Cooling OPTIMIZED FOR SEASONAL EFFICIENCY INDOOR UNIT FCQG71E FCQG100E FCQG125E FCQG140E Cooling capacity Nom. kw 7.1 3 10.0 3 12.0 14.0 3 Heating capacity Nom. kw 8.0 4 11.2 4-16 4 Power input
More informationAir Conditioning Technical Data RZAG-MV1
Air Conditioning Technical Data RZAG-MV1 TABLE OF CONTENTS RZAG-MV1 1 Features............................................................. 2 2 Specifications.......................................................
More informationAir Conditioners Heating & Cooling
Air Conditioners Heating & Cooling Ceiling suspended unit Energy label:» Up to class A Seasonal efficiency, optimized for all seasons Heat pump system Installation possible in new and existing buildings
More informationChillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps
Chillers Air cooled multi-scroll chillers and heat pumps High efficiency values both in cooling and heating mode Extremely wide operating range, outside ambient temperatures up to 52 C One or two refrigerant
More informationAir Conditioners Heating & Cooling
Air Conditioners & Cooling High COP, round flow cassette Seasonal efficiency, optimized for all seasons High COP cassette ensures top performance 360 air discharge Auto-cleaning cassette Even more comfort
More informationAir Conditioners Heating & Cooling
Air Conditioners & Cooling Concealed ceiling unit with inverter driven fan Seasonal efficiency, optimized for all seasons Discretely concealed in ceiling Reduced power consumption thanks to DC inverter
More informationAir conditioners Heating & Cooling
Air conditioners Heating & Cooling Wall mounted unit SEER and SCOP up to A ++ Discreet, modern design Whisper quiet in operation The right indoor for the right room www.daikin.eu FTXS20-25K/CTXS15-35K
More informationAir Conditioning Technical Data RZASG-MV1
Air Conditioning Technical Data RZASG-MV1 Outdoor Unit RZASG-MV1 TABLE OF CONTENTS RZASG-MV1 1 Features............................................................. 2 2 Specifications.......................................................
More informationPure comfort & design
Pure comfort & design Pure comfort Daikin introduces The best of two worlds united Heating & Cooling > heating & cooling in one Quiet and discrete, Nexura offers you the best in heating and cooling, in
More informationAir conditioners Heating & Cooling
Air conditioners Heating & Cooling Wall mounted unit SEER up to A++ Discreet, modern design Whisper quiet in operation The right indoor for the right room Heat pump system www.daikin.eu FTXS-20-25K/CTXS-15-35K
More informationAir Conditioning. Technical Data. High temperature hydrobox for VRV EEDEN HXHD-A8
Air Conditioning Technical Data High temperature hydrobox for VRV EEDEN15-204 Indoor Unit TABLE OF CONTENTS 1 Features............................................................. 2 2 Specifications.......................................................
More informationDaikin Sensira. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort
Daikin Sensira Refreshingly new Discreet wall mounted unit providing high efficiency and comfort Why choose Daikin 2 Creating the perfect indoor climate is what Daikin units are all about. With more than
More informationFan Coil Units. Technical Data FWC-BT/BF
Fan Coil Units Technical Data R o u n d f l o w c a s s e t t e E C D E N 1 2-4 0 0 FWC-BT/BF Fan Coil Units Technical Data R o u n d f l o w c a s s e t t e E C D E N 1 2-4 0 0 FWC-BT/BF Table of Contents
More informationwhere innovation meets creativity
where innovation meets creativity Stylish wall mounted unit Designed for comfort With more than 90 years of experience in air conditioning and climate control solutions, Daikin combines the best of design
More informationAir conditioners, heating & cooling for the retailmarket and offices
Air conditioners, heating & cooling for the retailmarket and offices floor standing unit air to air heat pumps www.daikin.eu FVQ-B MAXIMUM RELIABILITY, MINIMUM ENERGY USE Advanced climate systems in modern
More informationAir Conditioners Heating & Cooling
Air Conditioners Heating & Cooling C o n c e a l e d C e i l i n g U n i t Energy label:» Up to class A Heat pump system Seasonal inverter technology Flexible duct system for large areas Neatly concealed»
More informationAir Conditioners Heating & Cooling
Air Conditioners Heating & Cooling Ceiling Suspended Cassette»» Energy label:» Up to class A»» Heat pump system»» Seasonal inverter technology»» The ideal solution» for larger rooms»» Can be installed
More informationAir Purifiers. Technical Data MC70L
Air Purifiers Technical Data E E D E N - 7 0 0 MC70L Air Purifiers Technical Data E E D E N - 7 0 0 MC70L Single Unit MC70L TABLE OF CONTENTS MC70L Features.............................................................
More informationAir Conditioners Heating & Cooling
Air Conditioners Heating & Cooling C o n c e a l e d C e i l i n g U n i t Energy label:» Up to class A Heat pump system Seasonal inverter technology Flexible duct system for large areas Neatly concealed»
More informationAir Conditioners. Technical Data FTY-H
Air Conditioners Technical Data W a l l M o u n t e d U n i t E E D E N 1 0-1 1 0 FTY-H Air Conditioners Technical Data W a l l M o u n t e d U n i t E E D E N 1 0-1 1 0 FTY-H Indoor Unit Wall mounted
More informationtechnical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air
technical data RZQ-B ///Double Application, Inverter Controlled Unit air conditioning systems Split Sky Air Split - Sky Air ISO14001 assures an effective environmental management system in order to help
More informationDaikin Sensira R-32. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort
Daikin Sensira R-32 Refreshingly new Discreet wall mounted unit providing high efficiency and comfort Why choose Daikin 2 Creating the perfect indoor climate is what Daikin units are all about. With more
More informationVentilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF
Ventilation Technical Data Outdoor air processing unit, ventilation and air processing EEDEN13-205 FXMQ-MF TABLE OF CONTENTS FXMQ-MF 1 Features.............................................................
More informationAir Conditioners Heating & Cooling
Air Conditioners Heating & Cooling R o u n d F l o w C a s s e t t e F U L L R A N G E A C L A S S E N E R G Y L A B E L Seasonal efficiency, optimized for all seasons Heat pump system Round flow principle:
More informationDaikin leads the way:
Daikin leads the way: Offering a full range of light commercial products optimised for seasonal efficiency All Seasons Climate comfort Heating Air Conditioning Applied Systems Refrigeration Daikin leads
More informationPure comfort & design
Pure comfort & design Pure comfort Daikin introduces > COMFORT IS KEY Nexura makes your world a comfortable one. The coolness of a summer breeze or the cosiness of an extra heat source brings a feeling
More informationRemote control infrared ARC433B76 ARC433A8 ARC433B69
Cooling Only INDOOR UNITS FDKS25E FDKS35E FDKS50C FDKS60C Capacity cooling min~nom~max kw 1.3~2.4~3.0 1.4~3.4~3.8 1.7~5.0~5.3 1.7~6.0~6.5 Power input cooling min~nom~max kw -~0.69~- - ~1.09~- -~1.65~-
More informationAir Conditioners Heating & Cooling
Air Conditioners Heating & Cooling C o n c e a l e d C e i l i n g U n i t Energy label:» Up to class A Heat pump system Seasonal inverter technology Reduced power consumption thanks to DC inverter fan
More informationAir conditioners Heating & Cooling
Air conditioners Heating & Cooling Multi model application For residential and light commercial applications Energy efficient heating system Connect up to 9 indoor units Low energy bills and low CO 2 emissions
More informationEEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air
EEDEN08-00 technical data FTXS-G2VB Indoor units air conditioning systems Split - Sky Air EEDEN08-00 technical data FTXS-G2VB Indoor units air conditioning systems Split - Sky Air Indoor Units R-40A FTXS-G2VB
More informationEWAD-TZ. Air cooled chiller with R-134a inverter driven screw compressor
Air cooled chiller with R-134a inverter driven screw compressor New inverter compressor technology Today, Daikin is leading the way towards more efficient and cost-effective comfort solutions. All Daikin
More informationAir Conditioners Heating & Cooling
Air Conditioners Heating & Cooling 4 - W a y B l o w C e i l i n g M o u n t e d C a s s e t t e Energy label:» Up to class A Heat pump system Inverter technology Fits precisely» in standard modules» of
More informationFTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G
Cooling only INDOOR UNITS FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G Capacity cooling min~nom~max kw 1.3~2.0~2.8 1.3~2.5~3.2 1.4~3.5~4.0 1.7~4.2~5.0 1.7~5.0~5.3 1.7~6.0~6.7 2.3~7.1~8.5 Power
More informationtechnical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air
technical data RZQ-B9V3B_RZQ-B8W1B,, Triple, Double, Application, Inverter Controlled air conditioning systems Split Sky Air TABLE OF CONTENTS RZQ-B9V3B_RZQ-B8W1B 1 Features.............................................................
More informationAir Conditioning Technical Data AZAS-MY1
Air Conditioning Technical Data AZAS-MY1 Outdoor Unit AZAS-MY1 TABLE OF CONTENTS AZAS-MY1 1 Features............................................................. 2 2 Specifications.......................................................
More informationAir Conditioning. Technical Data. VRV IV S-series heat pump EEDEN16-200_2 RXYSQ-TV1
Air Conditioning Technical Data VRV IV S-series heat pump EEDEN16-0_2 RXYSQ-TV1 Outdoor Unit RXYSQ-TV1 TABLE OF CONTENTS RXYSQ-TV1 1 Features.............................................................
More informationInformation for end users. Floor standing units. 24/7 comfort in a contemporary package
Information for end users Floor standing units 24/7 comfort in a contemporary package Why choose Daikin? Daikin is the world leader when it comes to air conditioning and heating. Thanks to our constant
More informationAir Conditioners Heating & Cooling
Air Conditioners Heating & Cooling W a l l M o u n t e d U n i t For high ambient temperatures up to 52 C 50 Hz Heat pump system Energy efficient Dehumification without a drop in temperature Same comfort
More informationNew rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018
New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1 Extensive option package included in all models ErP compliant 2018 3 years warranty Daikin rooftops Flexible to suit your application Rooftop for Retail & Department
More informationAir conditioners Heating & Cooling
Air conditioners Heating & Cooling»» Up to five indoor units» on one outdoor unit M u l t i m o d e l a p p l i c a t i o n»» Individual control» per room»» Combination» of different indoor models»» Inverter
More informationDAIKIN Air Handling Unit Modular
DAIKIN Air Handling Unit Modular Compact ventilation unit with heat recovery Energy efficiency and air quality Daikin air handling units, with their plug-and-play design and inherent flexibility, can be
More informationAir Conditioners. Technical Data FTXS-G
Air Conditioners Technical Data I n d o o r u n i t s w w w. d a i k i n. e u FTXS-G Air Conditioners Technical Data I n d o o r u n i t s w w w. d a i k i n. e u FTXS-G Indoor Units R-410A FTXS-G TABLE
More informationtechnical data air conditioning systems FVXS-FV1B R-410A Split Sky Air
technical data FVXS-FV1B R-410A air conditioning systems Split Sky Air Indoor Units R-410A FVXS-FV1B TABLE OF CONTENTS FVXS-FV1B 1 Features.............................................................
More informationVZ Chiller series. Water cooled inverter chiller. The highest peak in chiller technology
VZ Chiller series Water cooled inverter chiller The highest peak in chiller technology The highest peak in chiller technology EWWD-VZ chiller series An increasing demand for high efficient HVAC systems
More informationAir conditioners, heating & cooling for shops,restaurants and offices
Air conditioners, heating & cooling for shops,restaurants and offices 4-way blow ceiling suspended unit air to air heat pumps www.daikin.eu FUQ-B made by daikin : WORLD-FAMOUS FOR EFFICIENCY By purchasing
More informationfor your home FLXS-B Flexi type unit air to air heat pumps
Air conditioners, HEATING & COOLING for your home Flexi type unit air to air heat pumps www.daikin.eu FLXS-B TOP CLASS, MADE FOR A LONG FUTURE The importance of well-being and pleasure is increasing in
More informationAir Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB
Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFAA2VEB > FFAA2VEB TABLE OF CONTENTS FFA-A 1 Features............................................................. 2 2 Specifications.......................................................
More informationAir conditioners Heating & Cooling
Air conditioners Heating & Cooling»» Up to five indoor units on one outdoor unit Multi model application»» Individual control per room»» Combination of different indoor models»» Inverter controlled www.daikin.eu
More informationOur mission: beating the winter cold
Optimised 4 Our mission: beating the winter cold Daikin s next-generation split range for colder climates Why choose Daikin 2 When the temperature drops below freezing, it s important you have the right
More informationemura Form. function. redefined.
emura Form. function. redefined. IT S ALL ABOUT DESIGN award winning design Daikin Europe N.V. is proud to announce that Daikin Emura has been awarded with several prestigious design awards: if Product
More informationw w w. d a i k i n. e u ATXS-E
Daikin air conditioners for your home WALL MOUNTED UNIT ATXS-E w w w. d a i k i n. e u Daikin s stylishly elegant wall mounted Siesta unit will grace the dining, living or bedroom of any home. Siesta will
More informationInformation for end users. Floor standing units. 24/7 comfort in a contemporary package
Information for end users Floor standing units 24/7 comfort in a contemporary package Why choose Daikin? Daikin is the world leader when it comes to air conditioning and heating. Thanks to our constant
More informationConcealed ceiling units
Concealed ceiling units Daikin concealed ceiling units an invisible improvement to any space Why choose Daikin? Daikin is a world leader in air conditioning and heating. So no matter what your needs, you
More informationAIR CONDITIONERS, HEATING & COOLING for your home
AIR CONDITIONERS, HEATING & COOLING for your home SLIM CONCEALED CEILING UNIT air to air heat pumps www.daikin.eu FDXS-E FDXS-C COMFORTABLE AIR, THE WHOLE YEAR THROUGH A comfortable living space provides
More informationAir conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B
Air conditioners, heating & cooling for large spaces CONCEALED CEILING UNIT air to air heat pumps www.daikin.eu FDQ-B THE MOST ADVANCED CLIMATE CONTROL FOR LARGE SPACES The quality air conditoning of Daikin
More information1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units
Features O u t d o o r U n i S p l i t S k y R Y N - E V B R - 4 0 a Outdoor units for pair application Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply
More informationEWAD-TZB. Screw inverter chiller. High efficiency chiller for comfort and process cooling
EWAD-TZB Screw inverter chiller High efficiency chiller for comfort and process cooling Why choose Daikin? Daikin were the among first to pioneer the use of inverters in air cooled screw chillers. And
More informationAir Conditioning. Technical Data. Concealed ceiling unit EEDEN ABQ-B
Air Conditioning Technical Data Concealed ceiling unit EEDEN3-3 ABQ-B TABLE OF CONTENTS ABQ-B Features............................................................. 2 2 Specifications.......................................................
More informationHeating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CW1
Heating Technical Data Daikin Altherma low temperature split EEDEN2-725 ERLQ-CW Daikin Altherma low temperature split ERLQ-CW TABLE OF CONTENTS ERLQ-CW Features.............................................................
More informationAir Conditioning. Technical Data. Concealed ceiling unit EEDEN ABQ-A
Air Conditioning Technical Data Concealed ceiling unit EEDEN3-3 ABQ-A Indoor Unit Concealed ceiling unit ABQ-A TABLE OF CONTENTS ABQ-A Features.............................................................
More informationAir Conditioning. Technical Data. VRV IV S-series compact heat pump EEDEN RXYSCQ-TV1
Air Conditioning Technical Data VRV IV S-series compact heat pump EEDEN16-100 RXYSCQ-TV1 TABLE OF CONTENTS RXYSCQ-TV1 1 Features............................................................. 2 2 Specifications.......................................................
More informationAir conditioners Cooling only
Air conditioners Rooftop, an economical solution for medium to large spaces Plug and play for easy installation High efficiency Quick cooling Wide operation range Compact unit www.daikinme.com UAT-CGXY
More informationIncluding mounting plate. General Rating Nameplate. Terminal strip with earth terminal
FTXB20-35C Rear side 770 Right side Standard location of holes in the wall 16 770 549 101 172 6 Left side Front panel fixing screws Including mounting plate 216 198 General Rating Nameplate 41.3 54.5 Hole
More informationfor small rooms in multi application
Air conditioners, heating & cooling for small rooms in multi application concealed ceiling unit air to air heat pumps www.daikin.eu FDbq-b HOSPITALITY STARTS WITH A STABLE AND DRAUGHT-FREE INDOOR CLIMATE
More informationEEDEN technical data ERHQ AA
EEDEN08-70 technical data Altherma Outdoor units R-410A Altherma Outdoor units 34 1 Features 1 O u t d o o r u n i A l t h e r m a E R H Q 0 1 1-0 1 6 A A R - 4 1 0 A Cost effective alternative to a fossil
More informationDaikin air conditioners for your home, shops, restaurants and offices
Daikin air conditioners for your home, shops, restaurants and offices CONCEALED CE ILING UN IT www.daikineurope.com FDEQ-B7 Concealed ceiling units are built into the false ceiling, leaving only the suction
More informationEWAT-B. Multi scroll chiller with R-32 refrigerant. First air cooled chiller with environmental friendly R-32 refrigerant
EWAT-B Multi scroll chiller with R-32 refrigerant First air cooled chiller with environmental friendly R-32 refrigerant Daikin, world s first company introducing a new generation of air cooled scroll chiller
More informationHigh temperature heating system AIR TO WATER HEAT PUMPS. Renovation - Heating - Domestic hot water
High temperature heating system AIR TO WATER HEAT PUMPS Renovation - Heating - Domestic hot water Daikin Altherma Heat pumps The solution with an eye to the future Renovating your heating system and wanting
More informationDAIKIN EMURA. FORM. FUNCTION. REDEFINED. THE NEW INDOOR AIR CONDITIONING UNIT FROM DAIKIN.
emura DAIKIN EMURA. FORM. FUNCTION. REDEFINED. THE NEW INDOOR AIR CONDITIONING UNIT FROM DAIKIN. 01 D5K_M027_Product Brochure.indd 1 27/10/09 11:30:28 STYLISH DESIGN TOTAL COMFORT ALL YEAR ROUND. The new
More information