Membrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification

Size: px
Start display at page:

Download "Membrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification"

Transcription

1 Membrane Air Dryer Series IDG Dew point indicator Dew point indicator visually confirms air drying (Except IDG) (Optional on IDG3, IDG5, IDG3H, IDG5H) Compact Lightweight Space-saving Type with fitting to purge air is also available. When purge air discharge is undesirable in the area around the membrane air dryer, it can be discharged to atmosphere via tubing (option). Discharged air noise reduced with built-in silencer Except IDG1, IDG3, IDG3H, IDG5, IDG5H, ( ) IDG3, IDG3H, IDG3L, IDG5, IDG5H, IDG5L Fitting to exhaust purge air for dew point checker Purge air discharge fitting for dehumidification Environmentally friendly (non-freon) Power supply not required No power supply is necessary. Wiring labor is not required and there is no need to consider electrical standards, etc. No vibration or heat discharge There are no mechanical moving parts as in the case of refrigeration equipment. Compatible with low dew points Outlet air atmospheric pressure dew point: 4 C ( IDG3L, IDG5L, IDG6L ) IDG75L, IDG1L Outlet air atmospheric pressure dew point: 6 C (IDG6S, IDG75S, IDG1S) Unit type Integrated prefilter and regulator IDG1 Flexible piping is possible Low flow rate type tube configuration Outlet air flow: 1 l/min (ANR) Dehumidification principle Air Dry air (oxygen, nitrogen, etc.) Moisture Orifice Purge air Hollow fiber Humid compressed air Type M Type V Mist separator + Micro mist separator + IDG Micro mist separator with prefilter The membrane air dryer uses hollow fibers composed of a macro molecular membrane through which moisture passes easily, but is difficult for air (oxygen and nitrogen) to pass through. When humid, compressed air is supplied to the inside of the hollow fibers, only moisture permeates the membrane and moves to the outside due to the pressure difference between the moisture inside and outside of the fibers. The compressed air becomes dry air and continues out of the dryer. Part of the dry air from the outlet side is passed through a very small orifice to reduce the pressure and purge the outside of the hollow fibers. The moisture which permeated to the outside of the hollow fibers is discharged to the atmosphere by this purge air. In this way, the partial pressure outside of the hollow fibers remains low and dehumidification is continuously performed. + IDG Mist separator + Micro mist separator + IDG + Regulator Micro mist separator with prefilter + IDG + Regulator Application example Machine tools (air bearings, lasers, etc.) Precision measuring equipment (3-D measuring machines) Semiconductor manufacturing equipment Semiconductor inspection equipment Dental equipment Chemical analysis equipment Ozonizers, Hydrogen gas generating equipment Packaging machines, Paper making machines, Food processing machines Printed circuit board IC mounting machines Fine particle drying, Transfer equipment Electrostatic and high grade coating Drying and cleaning of precision parts Condensation prevention in control panels General pneumatic equipment and pneumatic tools HA AT ID AMG AFF AM Misc.

2 Series Variations Meets a wide variety of flow rates (1 to 1 l /min (ANR)) and dew points (Atmospheric pressure dew point: 15 C to 6 C) Standard dew point: 2 C Note) Standard purge Note) Standard purge rate: 2% Standard dew point: 15 C Note) Low purge Note) Standard purge rate: 1% Standard dew point: 4 C Note) Low dew point Note) Standard purge rate: % Standard dew point: 6 C Note) Low dew point Note) Standard purge rate: 35% IDG1 is not available with standard dew point 15 C. Outlet air flow rate Note) Outlet air flow rate Note) Series (l /min (ANR)) Series (l /min (ANR)) Series Outlet air flow rate Note) (l /min (ANR)) Series Outlet air flow rate Note) (l /min (ANR)) Unit Type Single Unit Type IDG1 IDG3 IDG5 IDG1 IDG2 IDG3 IDG5 IDG6 IDG75 IDG1 IDG3M IDG5M IDG1M IDG2M IDG3M IDG5M IDG6M IDG75M IDG1M IDG3V IDG5V IDG1V IDG2V IDG3V IDG5V IDG6V IDG75V IDG1V IDG3H IDG5H IDG1H IDG2H IDG3H IDG5H IDG6H IDG75H IDG1H IDG3HM IDG5HM IDG1HM IDG2HM IDG3HM IDG5HM IDG6HM IDG75HM IDG1HM IDG3HV IDG5HV IDG1HV IDG2HV IDG3HV IDG5HV IDG6HV IDG75HV IDG1HV IDG3L IDG5L IDG6L IDG75L IDG1L IDG3LM IDG5LM IDG6LM IDG75LM IDG1LM IDG3LV IDG5LV IDG6LV IDG75LV IDG1LV IDG6S IDG75S IDG1S Type M A mist separator, micro mist separator, or micro mist separator with prefilter combined with a single unit Type V A regulator combined with the type M IDG6SM IDG75SM IDG1SM IDG6SV IDG75SV IDG1SV Note) Standard dew point : Outlet air atmospheric pressure dew point under standard performance conditions Standard purge rate : Ratio of purge air flow rate to inlet air flow rate under standard performance conditions Outlet air flow rate : Values under standard performance conditions

3 Membrane Air Dryer Series IDG Precautions Be sure to read before handling. Refer to pages to for Safety Instructions and Common Precautions on the products mentioned in this catalog, and pages to for Precautions on every series. Warning Caution on Design 1. Depending on the model and operating conditions, the oxygen ratio of the outlet air may drop below the prescribed standard. Do not use standard dew point 4 C (symbol L) type, standard dew point 6 C (symbol S) type and IDG3, 5, 3H, 5H for dehumidifying breathing air. Do not use only outlet air (dried air) in a closed room. Caution 1. Devise a layout which considers the position of purge air discharge ports. Purge air is humid air. Devise a layout in which purge air will not cause trouble such as corrosion or malfunction of peripheral equipment. 2. When very clean air is required (supply to air bearings, blowing of semiconductor parts, etc.) Install a micro mist separator or super mist separator on the outlet side (end terminal) of the membrane air dryer (unit). Grease is applied inside a regulator used in the unit (V type). When air with high purity is required, please either mount the above separator on the outlet side or use a made-to-order product (refer to page ), which is provided with a micro mist separator (Series AWD) instead of a regulator. 3. Time to reach the rated dew point A certain amount of time is required to achieve the rated dew point after the air begins flowing into the membrane air dryer. Using the times below as a guide, begin operating outlet side equipment after the rated dew point is achieved. Standard dew point 2 C, 15 C: about 1 min. Standard dew point 4 C: about 3 min. Standard dew point 6 C: about 12 min. This time can be shortened as described below. 1) Provide a valve on the outlet side of the membrane air dryer. 2) Supply air with the valve closed. Only purge air flows into the membrane air dryer. 3) After 15 minutes or more, open the valve and let air flow to the outlet side equipment. 4. Dehumidification performance when inlet air temperature changes Drying performance shows the case at an inlet air temperature of C. In other cases, please refer to How to Select a (page ) for proper selection. Caution Selection 1. Consider the purge air flow rate. Find the purge air flow rate from the charts and calculate the required outlet air flow rate + purge air flow rate. The air supply capacity must be at least equal to the calculated flow or the required outlet air flow rate cannot be obtained. 2. Selection for a compressed air line in which a mist separator or micro mist separator is already installed Verify the operating air flow rate and air pressure, and select a membrane air dryer in accordance with the model selection method (page ). If a membrane air dryer is selected using the port size of the equipment that is already installed as a reference, it could result in the selection of a model that is too small and has an insufficient dehumidification capacity. 3. With fittings for purge air discharge (Option: P) The dehumidification capacity decreases in proportion to the length of the tube for discharging purge air. Use a tube of the specified size and keep its length within 5 m. For the outlet air atmospheric pressure dew point in relation to the length of the tube for discharging purge air, refer to the table Outlet Dew Point at Atmospheric Pressure to Tube for Exhaust of Purge Air on page Auto-drain selection for the unit style When the compressor in use is for 2.2 kw {3 l/min (ANR)} or less, please use an N.C. auto drain (symbol: C). If an N.O. auto drain (symbol: D) is used when the compressor is for 2.2 kw or less, pressure inside the mist separator may not increase and remain in the state of blowing off. Auto drain with differential pressure type can be used in 2.2 kw or less. Mounting Caution 1. Do not obstruct the purge air discharge ports. If purge air back pressure becomes too high or purge air stops flowing, dehumidification performance will decrease or may become impossible. 2. Be sure to install a mist separator and micro mist separator or a micro mist separator with prefilter on the inlet side of the membrane air dryer. If the inlet air contains oil or water drops, etc., performance will be reduced. (A mist separator and micro mist separator or a micro mist separator with prefilter are already installed on the unit types.) 3. Install a regulator on the outlet side of the membrane air dryer. If it is installed on the inlet side, dehumidification performance will be reduced. 4. Take sufficient care in handling. There is a danger of damage if dropped. HA AT ID AMG AFF AM Misc

4 Series IDG Precautions Be sure to read before handling. Refer to pages to for Safety Instructions and Common Precautions on the products mentioned in this catalog, and pages to for Precautions on every series. Warning Piping 1. Confirm locking of case and body. When using in a unit, be sure to set the air pressure to zero before using a mist separator or micro mist separator with modular connections. Also, confirm that the body and case are locked together with a click before starting the flow of compressed air. 2. Confirm tightening of the holder. (for IDG3 to IDG1, IDG3H to IDG1H, IDG3L to IDG1L and IDG6S to IDG1S) Before starting the flow of compressed air, turn the membrane air dryer's holder in its tightening direction, confirming that it is completely tightened and that the case will not come off. 3. Minimum bending radius (for IDG1) When installing piping for the membrane air dryer, maintain a minimum bending radius of 35 mm or more. Furthermore, do not bend the sections that are within 5 mm of the ends of the membrane module. 4. With fittings for purge air discharge (Option: P) The piping of purge air for dehumidification and for the dew point checker can be combined, but do not merge these with compressed air lines or drain piping, etc., as this can cause damage. 5 Min. bending radius: 35 5 sections cannot be bent. Caution Piping 1. Use of tools Hold the upper portion of the body (die-cast aluminum section) with a spanner or adjustable angle wrench. Do not turn it while holding the case section. 2. piping for separators When installing drain piping for mist separators or micro mist separators, use a tube of the prescribed size and keep the length within 5 meters or less. Also, be sure that the tube does not rise up or become folded over. 3. Piping materials for low dew point air If air of a low dew point ( 4 C or less) is required, do not use a nylon tube piping for the outlet side of the membrane air dryer. Due to the nature of the nylon tube, it could be affected by the ambient air, and it might not be possible to achieve the prescribed low dew point at the end of the tube. Therefore, for low dew point air, use a stainless steel or fluoropolymer piping. 4. With fittings for purge air discharge (Option: P) (for IDG6 to IDG1, IDG6H to IDG1H, IDG6L to IDG1L and IDG6S to IDG1S) To install piping for dehumidification purge air discharge, attach tubing of the prescribed size to the hose nipple section and then secure it with tubing bands. Caution Air Supply 1. Compressed air supply Air Supply capacity An air source that has a supply capacity that is larger than the necessary outlet air flow rate (dry air flow rate) + purge air flow rate is required. Verify the purge air flow rate in the Purge Air Flow Characteristics. (page ) Operating Environment Caution 1. Do not use at temperatures (fluid or ambient temperatures) higher than the prescribed operating conditions. Resin is used in the membrane module, and it can be damaged by operation at high temperatures. Especially when installed immediately after a reciprocating type air compressor, confirm that the fluid temperature does not exceed the range of operating conditions during use. 2. Keep the inlet air temperature lower than the ambient temperature. If the membrane air dryer, s body is cooled by the surrounding air, water drops may accumulate inside and reduce its dehumidification capacity

5 Membrane Air Dryer Series IDG Maintenance Precautions Be sure to read before handling. Refer to pages to for Safety Instructions and Common Precautions on the products mentioned in this catalog, and pages to for Precautions on every series. Warning 1. Do not remove the orifice (plug) when in a pressurized state. Never remove the orifice (plug) while under pressure, as it can fly out causing a hazard. Caution 1. Confirming the dehumidification function with the dew point indicator Observe the color of the dew point indicator to confirm whether the membrane air dryer is functioning normally. [When dew point indicator color is blue: Functioning normally] [When the color of the dew point indicator is pink: Dew point temperature is high. (Outlet air is humid.) Note: Atmospheric pressure dew point approximately 1 C minimum.] If humid air flowing in turns the color pink. If dry air then enters, the color turns back to blue. It takes about 1 hour from the start of air flow for the dew point indicator color to change. 2. Dew point indicator replacement period The absorbent is used in the dew point indecator. It absorbs the gasified oil in the compressed air and/or the gaseous elements other than the air, and then may turn brown. When it turned brown, replace the dew point indicator. Besides, in the event of replacing them periodically, carry out after two-year operation as a guideline. (For the part number of the dew point indicator, refer to page to 29.) 3. Element replacement period Refer to the following guide when replacing the elements in the mist separator and in the micro mist separator, or micro mist separator with prefilter that are installed on the inlet side of the membrane air dryer. 1) When two years have passed since installation. 2) When the unit s pressure drop reaches.2 MPa, even before the two year period is reached. 3) When the red portion of the dew point indicator reaches the upper limit. (With micro-mist separator with pre-filter) [IDG6M to IDG1M, IDG6HM to IDG1HM, IDG6V to IDG1V, IDG6HV to IDG1HV] Note 1) Note 1) For other models as well, they are available with the dewpoint indicator under made-to-order. Refer to page Membrane module replacement period Replace the membrane module when the color of the dew point indicator turns white or pink. As a guideline, unit should be replaced after approximately 1 years of use (1 hours/day operation). Replace it when the color of the dew point indicator turns white or pink, even if it is within the period. 5. Tightening torque for installing the membrane module and the case (for IDG5/1/2/5H/1H/2H) Use caution not to tighten excessively. It may result in a breakdown of membrane module, case and mounting screws or insufficient sealing. (Verify the tightening torque range in the instruction manual.) 6. Installing a pressure gauge A pressure gauge should be installed on the inlet and outlet sides of the membrane air dryer (unit) for the maintenance and inspection purposes. HA AT ID AMG AFF AM Misc

6 Selection Series IDG Selection Step 1 Confirmation of operating conditions Outlet air flow rate [l /min (ANR)] Outlet air atmospheric pressure dew point [ C] (When it is necessary to convert from the pressurized dew point, refer to the conversion diagram for dew point temperature below.) Inlet air pressure [MPa] Inlet air temperature [ C] Allowable pressure drop P [MPa] Compressed air supply capacity Q [l /min (ANR)] [Example] Outlet air flow rate Outlet air dew point Inlet air pressure Inlet air temperature Allowable pressure drop Compressed air supply capacity 15 [l /min (ANR)] 15 [ C].5 [MPa] 35 [ C].3 [MPa] 3 [l /min (ANR)] Dew Point Temperature Conversion Chart Pressure dew point ( C) MPa.7 MPa.5 MPa.3 MPa.1 MPa Atmospheric pressure Atmospheric pressure dew point ( C)

7 Membrane Air Dryer Series IDG Step 2 Correction of the outlet air flow rate influenced by the inlet air temperature. (When the inlet air temperature is C, refer to Step 4) Step 3 When the inlet air temperature is not the same temperature ( C) on the performance charts, calculate the correction factor for the outlet air flow rate from the chart below to compensate the outlet air flow rate. Example Inlet air temperature35 C Outlet air flow 15 l/min (ANR) Inlet air temperature ( C) From table below (Inlet Air Temperature Correction Factor for Outlet Air Flow rate) Correction factor for outlet air flow rate is.4 for Type A products group.86 for Type B products group Therefore, corrected outlet air flow rate can be determined. [Type A products group] 15.4 = 375 l/min (ANR) [Type B products group] = 175 l/min (ANR) Inlet Air Temperature Correction Factor for Outlet Air Flow Rate Note) Correction factors between the products A group and the products B group are different from each other, because the module characteristics are different. Example Type A products group Standard dew point 2 C In the case of 15 C (symbol H) type (but, except IDG3, 5, 3H, 5H) selection based on corrected outlet flow rate Corrected outlet air flow375 l/min (ANR) [Type A product group] Corrected outlet air flow175 l/min (ANR) [Type B product group] Inlet air pressure.5 MPa Outlet air dew point 15 C Step 4 Confirmation of purged air flow rate Type B products group Standard dew point 4 C In the case of 4 C (symbol L) type and IDG3, 5, 3H, 5H Select a model based on the corrected outlet air flow rate calculated by Step 2 on the flow characteristics charts on pages , 18, 21, 22,, and 27. With the conditions of the corrected outlet air flow and the inlet air pressure mentioned to the left, the outlet air atmospheric pressure dew point is found to be 15 C or below. When selecting a model [Type A product group] IDG6 [Type B product group] IDG3, IDG5H Read out from the graph on the purged air flow rate (page ). Example Inlet air pressure.5 MPa selection IDG3 In the case of IDG356 l/min (ANR) IDG5H In the case of IDG5H 45 l/min (ANR) IDG6 In the case of IDG694 l/min (ANR) Step 5 Calculation of inlet air flow rate Q1, and confirmation of compressed air supply capacity. Inlet air flow rate Q1 [l/min (ANR)] = Outlet air flow rate [l/min (ANR)] + Purge air flow rate [l/min (ANR)] Example: Assuming that IDG3 is chosen by Step 4 Outlet air flow rate 15 l/min (ANR) Purge air flow rate 56 l/min (ANR) Compressed air supply capacity Q 3 l/min (ANR) Step 1 Step 6 Confirmation of pressure drop P1 [MPa] Step 1 or Step 2 NO Review operating conditions. Step 6 Single unit (Refer to pages and 13.) Unit (Refer to pages and 38.) NO Review operating conditions or increase size. Confirmation of compressed air supply capacity Q Q1 P P1 YES YES 3 26, therefore proceed to Step 6 In the case of IDG3 and IDG3M (with the element in the initial state), P P1, therefore proceed to Step 7. Step 7 The way of discharging drain (in the case of unit), accessories and optional specifications Example In the case of IDG3 With Accessories: Bracket Option specifications: None In the case of IDG3M The way of discharging drain: N.O. auto-drain Option specifications: None The inlet air flow rate Q1 = = 26 l/min (ANR) Example: to be selected in case of IDG3 Single unit IDG3 Inlet air pressure.5 MPa on the flow characteristics (page ), Inlet air flow 26 l/min (ANR) P1 =.6 MPa Allowable pressure drop P Unit IDG3M.3 MPa P1 =.1 MPa (Element initial state) P1 =.55 MPa (Element saturated state) Single unit (Refer to pages , 2, 24, and 26.) Unit (Refer to page ) Refer to Selection in Specific Product Precautions on page selected <In the case of single unit type> IDG3-3B <In the case of unit type> IDG3M-3D HA AT ID AMG AFF AM Misc

8 Series IDG Flow Characteristics IDG1 (Standard dew point: 2 C) IDG3 (Standard dew point: 2 C), IDG3H (Standard dew point: 15 C) IDG5 (Standard dew point: 2 C), IDG5H (Standard dew point: 15 C) IDG1 (Standard dew point: 2 C), IDG1H (Standard dew point: 15 C) IDG2 (Standard dew point 2 C), IDG2H (Standard dew point 15 C) IDG3 (Standard dew point 2 C), IDG3H (Standard dew point 15 C), IDG3L (Standard dew point 4 C) IDG5 (Standard dew point: 2 C), IDG5H (Standard dew point: 15 C), IDG5L (Standard dew point: 4 C) IDG6 (Standard dew point: 2 C), IDG6H (Standard dew point: 15 C)

9 Membrane Air Dryer Series IDG Conditions: Inlet air temperature C, P1: Inlet air pressure IDG6L (Standard dew point: 4 C), IDG6S (Standard dew point: 6 C) IDG75 (Standard dew point: 2 C), IDG75H (Standard dew point: 15 C) IDG75L (Standard dew point: 4 C), IDG75S (Standard dew point: 6 C) IDG1 (Standard dew point: 2 C), IDG1H (Standard dew point: 15 C) IDG1L (Standard dew point: 4 C), IDG1S (Standard dew point: 6 C) HA AT ID AMG AFF AM Misc

10 Series IDG Purge Air Flow Characteristics Conditions: Inlet air temperature C IDG1/3/5/1/2 (Standard dew point: 2 C) IDG3H/5H/1H/2H (Standard dew point: 15 C) IDG3/5 (Standard dew point: 2 C) IDG3H/5H (Standard dew point: 15 C) IDG3L/5L (Standard dew point: 4 C) 6 IDG2 18 IDG Purge air flow rate (l/min (ANR)) IDG1 IDG2H IDG5 IDG1H IDG3, IDG5H IDG3H IDG1 Purge air flow rate (l/min (ANR)) IDG3 IDG5H IDG5L IDG3H IDG3L Inlet air pressure (MPa) Inlet air pressure (MPa) IDG6/75/1 (Standard dew point: 2 C) IDG6H/75H/1H (Standard dew point: 15 C) IDG6L/75L/1L (Standard dew point: 4 C) IDG6S/75S/1S (Standard dew point 6 C) 28 IDG1 14 IDG1L IDG1S IDG75 Purge air flow rate (l/min (ANR)) IDG6 IDG1H IDG75H IDG6H Purge air flow rate (l/min (ANR)) IDG75L IDG6L IDG75S IDG6S Inlet air pressure (MPa) Inlet air pressure (MPa)

11 HA AT ID AMG AFF AM Misc

12 Membrane Air Dryer Single Unit Type Series IDG Single Unit/Standard Dew Point 2 C Specifications IDG 1 How to Order 3 Flow rate by size Outlet air flow rate l/min Size Purge air flow rate (ANR) 1 1/2.5 3 /6 5 5/12 1 1/ 2 2/5 3 3/75 5 5/1 6 6/ /15 1 1/19 Thread type Nil N F Rc NPT G Note) In the case of two or more options, indicate them alphabetically. Accessory Nil B Note) When symbol B is indicated, a bracket assembly with a part number shown in the table below is included as an accessory. Port size Symbol Bore Size /8 2 1/4 3 3/8 4 1/2 Option Symbol Contents Size Nil None (Standard) P With fitting for purge air discharge R Flow direction (Right Left) S With dew point indicator Standard equipment None (Standard) With bracket (Except IDG1) Standard Specifications/Single Unit Type (Standard dew point: 2 C) IDG1 IDG1 JIS Symbol Bracket Assembly (Accessory) Part No. Part no. BM59 BM61 BM63 BM64 BM65 Applicable model IDG3, 5 IDG1 IDG2 IDG3/5 IDG6/75/1 With cap bolts and spring washers IDG3 Range of operating conditions Standard performance Standard performance conditions Fluid Inlet air pressure (MPa) Inlet air temperature ( C) (1) 5 to 55 Ambient temperature ( C) 5 to 55 Outlet air atmospheric pressure dew point ( C) Inlet air flow rate (l/min(anr)) (2) Outlet air flow rate (l/min(anr)) Purge air flow rate (l/min(anr)) (3) Inlet air pressure (MPa) Inlet air temperature ( C) Inlet air saturation temperature ( C) Ambient temperature ( C) Dew point indicator purge air flow rate Port size (Nominal size B) Weight (kg) (With bracket) IDG1 IDG3 Standard dew point: 2 C IDG5 IDG1 IDG2 IDG3 IDG5 IDG6 IDG75 IDG1 Compressed air.3 to.85.3 to to 5 5 to l/min (ANR) {In case of Inlet air pressure.7 MPa} 1/4 1/8, 1/4 1/4, 3/8 3/8, 1/2 1/2.11. (.31).43 (.51) (.76).66 (.87).74 (.9).77 (1.65) 1.5 (1.65) 1.5 (1.7) 1.55 Note 1) No freezing. Note 2) ANR indicates the flow rate converted to the value at 2 C under the atmospheric pressure and the state of relative humidity 65%. Note 3) Includes 1 l/min (ANR) of purge air flow (at.7 MPa inlet air pressure) for the dew point indicator (except IDG1, 3, 5).

13 Membrane Air Dryer Single Unit Type Series IDG Performance Chart Conditions: Inlet air temperature C (saturated air), Ambient temperature C, P1: Inlet air pressure, Tube for purge air discharge (Option: P): None Notice: In the case of products with fitting for purge air discharge (Option: P), refer to page Product groups inside parentheses in the graph are classification symbols for selecting a model. (Refer to page ) IDG1 (Type A products group) IDG3 (Type A products group) IDG5 (Type A products group) IDG1 (Type A product group) IDG2 (Type A products group) IDG5 (Type B products group) IDG3 (Type B products group) IDG6 (Type A products group) HA AT ID AMG AFF AM Misc

14 Series IDG Performance Chart Conditions: Inlet air temperature C (saturated air), Ambient temperature C, P1: Inlet air pressure IDG75 (Type A products group) IDG1 (Type A products group) With fittings for purge air discharge (Option: P) As the length of tubing for purge air discharge becomes longer, the outlet air atmospheric pressure dew point becomes higher. Refer to the table below. Outlet Air at the Atmospheric Pressure Dew point in Compliance with the Tube Length for Discharging the Purged Air ( C) IDG3 IDG5 Tube length m 1 m 3 m 5 m Note) In cases other than above model numbers, if the tube length is 5 m or less, an increase of the outlet air at the atmospheric pressure dew point will be 1 C or less. Conditions Inlet air temperature : C (Saturated) Ambient temperature : C Inlet air pressure Outlet air flow rate Tubing size (O.D. x I.D.) mm: ø12 x ø9 :.7 MPa : Flow gained under conditions of the standard performance. (Refer to page ) Construction Refer to pages to 29. Dimensions Refer to pages to

15 HA AT ID AMG AFF AM Misc

16 Single Unit/Standard Dew Point 15 C Specifications IDG 1 H How to Order 3 Flow rate by size Outlet air flow rate Size Purge air flow rate 3 /3 5 5/6 1 1/11 2 2/22 3 3/35 5 5/6 6 6/ /8 1 1/11 Standard dew point temperature Symbol H l /min(anr) Standard dew point ( C) 15 Thread type Nil N F Rc NPT G Accessory Option Note) When symbol B is indicated, a bracket assembly with a part number shown inthe table below is included as an accessory. Port size Symbol Nil B Bore 1 1/8 2 1/4 3 3/8 3 Size /2 Symbol Contents Size Nil None (Standard) P With fitting for purge air discharge R Flow direction (Right Left) S With dew point indicator Standard equipment Note) In the case of two or more options, indicate them alphabetically. None (Standard) With bracket IDG3H Part no. BM59 BM61 BM63 BM64 BM65 IDG1H JIS Symbol Bracket Assembly (Accessory) Part No. Applicable model IDG3H/5H IDG1H IDG2H IDG3H/5H IDG6H/75H/1H With cap bolts and spring washers IDG3H Standard Specifications/Single Unit Type (Standard dew point: 15 C) Range of operating conditions Standard perfor mance Standard performance conditions Fluid Inlet air pressure (MPa) Inlet air temperature ( C) (1) Ambient temperature ( C) Outlet airatmospheric pressuredew point ( C) Inlet air flow rate (l/min(anr)) (2) Outlet air flow rate (l/min(anr)) Purge air flow rate (l/min(anr)) (3) Inlet air pressure (MPa) Inlet air temperature ( C) Inlet air saturation temperature ( C) Ambient temperature ( C) Dew point indicator purge air flow rate Port size (Nominal size B) Weight (kg) (With bracket) IDG3H 28 3 Standard dew point 15 C IDG5H IDG1H IDG2H IDG3H IDG5H IDG6H IDG75H IDG1H Compressed air.3 to.85.3 to 1. 5 to 55 5 to 5 5 to 55 5 to l/min (ANR) {In the case of Inlet air pressure.7 MPa} 1/8, 1/4 1/4, 3/8 3/8, 1/2 1/2. (.31).43 (.51).66 (.76).74 (.87).77 (.9) 1.5 (1.65) 1.5 (1.65) 1.55 (1.7) Note 1) No freezing. Note 2) ANR indicates the flow rate converted to the value at 2 C under the atmospheric pressure and the state of relative humidity 65%. Note 3) Includes 1 l/min (ANR) of purge air flow (at.7 MPa inlet air pressure) for the dew point indicator (except IDG3H, 5H)

17 Membrane Air Dryer Single Unit Type Series IDG Performance Chart Conditions: Inlet air temperature C (saturated air), Ambient temperature C, P1: Inlet air pressure, Tube for purge air discharge (Option: P): None Notice: When using product with fittings for purge air discharge (Option: P) and if the tube lengthis 5 m or less, an increase of the outlet air dew point is 1 C or less. Product groups inside parentheses in the graph are classification symbols for selecting a model. (Refer to page ) IDG3H (Type A products group) P1 =.3 MPa IDG5H (Type A products group) IDG1H (Type A products group) P1 =.3 MPa IDG2H (Type A products group) IDG3H (Type B products group) IDG6H (Type A product group) IDG5H (Type B products group) IDG75H (Type A products group) HA AT ID AMG AFF AM Misc.

18 Series IDG Performance Chart Conditions: Inlet air temperature C (saturated air), Ambient temperature C, P1: Inlet airpressure,tube for purge air discharge (Option: P): None Notice: When using products with fitting for purge air discharge (Option: P) and if the tube length is 5 m or less, an increase of the outlet air dew point is 1 C or less. IDG1H (Type A products group) Construction Refer to pages to 29. Dimensions Refer to pages to

19 HA AT ID AMG AFF AM Misc

20 Series IDG Single Unit/Standard Dew Point 4 C Specifications IDG 5 L How to Order 3 Size Standard dew point temperature Symbol L Flow rate by size Outlet air flow rate Purge air flow rate (l/min(anr)) 75/ 11/4 17/57 24/8 3/1 Standard dew point (N) 4 Accessory Option Nil P R Flow direction (Right Left) Note) In the case of two or more options, indicate them alphabetically. Nil None (Standard) B With bracket Note) When symbol B is indicated, a bracket assembly with a part number shown in the table below is included as an accessory. None (Standard) With fitting for purge air discharge Thread type Nil N F Rc NPT G Port size Symbol Bore 2 1/4 3 3/ /2 5 Size Standard Specifications/Single Unit Type (Standard dew point: 4 C) IDG3L JIS Symbol Bracket Assembly (Accessory) Part No. IDG6L Part no. Applicable model BM64 IDG3L/5L BM65 IDG6L/75L/1L With cap bolts and spring washers Range of operating conditions Standard performance Standard performance conditions Fluid Inlet air pressure (MPa) Inlet air temperature ( C) (1) Ambient temperature ( C) Outlet air atmospheric pressure dew point ( C) Inlet air flowrate (l/min(anr)) (2) Outlet air flowrate (l/min(anr)) Purge air flowrate (l/min(anr)) (3) Inlet air pressure (MPa) Inlet air temperature ( C) Inlet air saturation temperature ( C) Ambient temperature ( C) Dew point indicator purge air flow rate Port size (Nominal size B) Weight (kg) (With bracket) Standard dew point: 4 C IDG3L IDG5L IDG6L IDG75L IDG1L Compressed air.3 to 1. 5 to 5 5 to (.87).7 1 l/min (ANR) {In the case of Inlet air pressure.7 MPa} 1/4, 3/8 3/8, 1/2.77 (.9) 1.5 (1.65) 1.65 (1.8) 1.8 (1.95) Note 1) No freezing. Note 2) ANR indicates the flow rate converted to the value at 2 C under the atmospheric pressure and the state of relative humidity 65%. Note 3) Includes 1 l/min (ANR) of purge air flow (at.7 MPa inlet air pressure) for the dew point indicator

21 Membrane Air Dryer Single Unit Type Series IDG Performance Chart Conditions: Inlet air temperature C (saturated air), Ambient temperature C P1: Inlet air pressure, Tube for purge air discharge (Option: P): None Product groups inside parentheses in the graph are classification symbols for selecting a model. (Refer to page ) IDG3L (Type B products group) IDG5L (Type B products group) IDG6L (Type B products group) IDG75L (Type B products group) IDG1L (Type B products group) With fitting for purge air discharge (Option: P) As the length of tubing for purge air discharge becomes longer, the outlet air atmospheric pressure dew point becomes higher. Refer to the table below. Outlet Air at the Atmospheric Pressure Dew point in Compliance with the Tube Length for Discharging the Purged Air ( C) Tube length m 1 m 3 m 5 m IDG3L IDG5L Note) In cases other than above model numbers, if the tube length is 5 m or less, an increase of the outlet air at the atmospheric pressure dew point will be 1 C or less. Construction Dimensions Refer to pages to 29. Refer to pages to 31. Conditions Inlet air temperature : C (Saturated) Ambient temperature : C Inlet air pressure :.7 MPa Outlet air flow rate : Flow gained under conditions of the standard performance.(refer to page ) Tubing size (O.D. x I.D.) mm: ø12 x ø HA AT ID AMG AFF AM Misc.

22 Series IDG Single Unit/Standard Dew Point 6 C Specifications IDG 6 S How to Order 3 B Size Flow rate by size Outlet air flow rate Purge air flow rate (l/min(anr)) 5/27 1/54 15/85 Standard dew point temperature Symbol S Standard dew point ( C) 6 Thread type Nil N F Rc NPT G Port size Symbol 3 3/8 4 1/2 Option Accessory Nil None (Standard) B With bracket Note) When symbol B is indicated, a bracket assembly with a part number shown in the table below is included as an accessory. Bore Nil P R Size None (Standard) With fitting for purge air discharge Flow direction (Right Left) Note) In the case of two or more options, indicate them alphabetically. Standard Specifications/Single Unit Type (Standard dew point: 6 C) Bracket Assembly (Accessory) Part No. Part no. BM65 IDG6S JIS Symbol Applicable model IDG6S/75S/1S With cap bolts and spring washers Range of operating conditions Standard performance Standard performance conditions Fluid Inlet air pressure (MPa) Inlet air temperature ( C) Inlet air saturation temperature ( C) Ambient temperature ( C) Dew point indicator purge air flow rate Port size (Nominal size B) Weight (kg) (With bracket) Inlet air temperature ( C) (1) Ambient temperature ( C) Outlet air atmospheric pressure dew point ( C) Inlet air flow rate (l/min(anr)) (2) Outlet air flow rate (l/min(anr)) Purge air flow rate (l/min(anr)) (3) Inlet air pressure (MPa) Standard dew point: 6 C IDG6S IDG75S IDG1S Compressed air.3 to 1. 5 to 5 5 to l/min (ANR) {In the case of Inlet air pressure.7 MPa} 3/8, 1/ (1.65) (1.8) (1.95) Note 1) No freezing. Note 2) ANR indicates the flow rate converted to the value at 2 C under the atmospheric pressure and the state of relative humidity 65%. Note 3) Includes 1 l/min (ANR) of purge air flow (at.7 MPa inlet air pressure) for the dew point indicator

23 Membrane Air Dryer Single Unit Type Series IDG Performance Chart Conditions: Inlet air temperature C (saturated air), Ambient temperature C, P1: Inlet air pressure, Tube for purge air discharge (Option: P): None Notice: When using products with fitting for purge air discharge (Option: P) and if the tube length is 5 m or less, an increase of the outlet air dew point is 1 C or less. Product groups inside parentheses in the graph are classification symbols for selecting a model. (Refer to page ) IDG6S (Type B products group) IDG75S (Type B products group) IDG1S (Type B products group) HA AT ID AMG AFF AM Misc

24 Series IDG Construction IDG1 q e t w Purge air for dehumidification Option specifications With fitting for purge air discharge (Option: P) Purge air for dehumidification IDG3/5 IDG3H/5H Plug Plug t q Option specifications With fitting for purge air discharge (Option: P) IDG1/2 IDG1H/2H i t q Option specifications With fitting for purge air discharge (Option: P) } o Purge air for dehumidification u Plug y u Purge r Purge Purge air for dehumidification Component Parts No. q w e r t y Description Body Female connector Strainer Case Orifice Silencer Replacement Parts No. u i o Description Membrane module kit Dew point indicator kit IDG1 IDG3/3H IDG5/5H IDG1/1H IDG2/2H Copper alloy Copper alloy Copper alloy Resin Material Aluminum alloy Resin Stainless steel Copper alloy IDG1 IDG3/3H IDG5/5H IDG1/1H IDG2/2H IDG-EL3 IDG-EL3H Part no. IDG-EL5 IDG-EL5H IDG-DP1 (Option: S) IDG-DP1-X1 (Option: PS) IDG-EL1 IDG-EL1H IDG-DP1 IDG-EL2 IDG-EL2H IDG-DP1-X1 (Option: P) Note Platinum silver coated (IDG1 is electroless nickel plated.) Electroless nickel plated IDG3H is resin. Note

25 Membrane Air Dryer Single Unit Type Series IDG IDG3/5 IDG3H/5H IDG3L/5L u q r e Option specifications With fitting for purge air discharge (Option: P) } i w y Purge air for dehumidification IDG6/75/1 IDG6H/75H/1H IDG6L/75L/1L IDG6S/75S/1S u q r e t Purge air for dehumidification Option specifications With fitting for purge air discharge (Option: P) } i w y HA Purge air for dehumidification Purge air for dehumidification AT ID AMG Component Parts No. q w e r t Description Body Case Orifice Holder Silencer Replacement Parts No. Description IDG3/3H/3L IDG5/5H/5L IDG6/6H/6L/6S IDG75/75H/75L/75S IDG1/1H/1L/1S Aluminum alloy Material Aluminum alloy Stainless steel Stainless steel Part no. Aluminum Resin + Copper alloy IDG3/3H/3L IDG5/5H/5L IDG6/6H/6L/6S IDG75/75/75L/75S IDG1/1H/1L/1S Note Platinum silver coated Note AFF AM Misc. y u i Membrane module kit Dew point indicator kit IDG-EL3 IDG-EL5 IDG-EL6 IDG-EL6L IDG-DP1 IDG-DP1-X1 IDG-EL75 IDG-EL75L IDG-EL1 IDG-EL1L Option: P

26 Series IDG Dimensions IDG1 (293) Purge air outlet for dehumidification (67) (46) (26) Port size: 1/4 Hexagon width across flats 19 Hexagon width across flats 14 With fitting for purge air discharge (Option: P) (86) Purge air outlet for dehumidification (67) ø8 Hexagon width across flats 14 Hexagon width across flats 17 Port size: 1/4 Purge air discharge tubing port for dehumidification Applicable tubing O.D.: ø6 (NPT thread: ø1/4 inch) (34) () Hexagon width across flats 14 Hexagon width across flats 17 IDG3, 5 IDG3H, 5H Dew point indicator (Option: S) Purge air 12 With fitting for purge air discharge (Option: P) Bracket (Accessory: B) Port size: 1/8, 1/4 (Maintenance space 1 mm or more) IDG1, 2 IDG1H, 2H A E Purge air D B (98) Purge air for dehumidification Purge air discharge tubing port for dehumidification Applicable tubing O.D.: ø8 ø5/16 inch (64) With fitting for purge air discharge (Option: P) 14 7 Port size L C Purge air discharge tubing port for dehumidification Applicable tubing O.D.: ø8 ø5/16 inch (H) Bracket (Accessory: B) (G) Purge air for dehumidification Purge air for dehumidification Purge air discharge tubing port for dehumidification Applicable tubing O.D.: øj (NPT thread: øk inch) (F) (Maintenance space 1 mm or more) Port size Option: P A B C D E L F G H J K IDG1/1H [126] 8 5/16 1/4, 3/8 IDG2/2H [154] 1 3/8 Values inside [ ] are for NPT threads

27 Membrane Air Dryer Single Unit Type Series IDG IDG3/5 IDG3H/5H IDG3L/5L Purge air Port size L Purge air discharge tubing port for dew point indicator Applicable tubing O.D. ø8 ø5/16 inch With fitting for purge air discharge (Option: P) 18 8 Bracket (Accessory: B) (D) (B) (G) (H) Purge air for dehumidification Purge air discharge tubing port for dehumidification Applicable tubing O.D.: ø12 (NPT threads: ø1/2 inch) (Maintenance space 1 mm or more) IDG6/75/1 IDG6H/75H/1H IDG6L/75L/1L IDG6S/75S/1S Purge air Port size L 91 5 With fitting for purge air discharge (Option: P) Purge air discharge tubing 2.3 port for dew point indicator 24 Applicable tubing O.D.: ø8 ø5/16 inch Bracket (Accessory: B) HA (D) (B) (H) (G) AT ID AMG Purge air for dehumidification AFF AM (Maintenance space 1 mm or more) Misc. Port size Option: P B D L G H IDG3/3H/3L /4, 3/8 IDG5/5H/5L IDG6/6H 3/8, 1/2 IDG75/75H/1/1H 1/ IDG6L/6S IDG75L/75S 3/8, 1/ IDG1L/1S Purge air discharge tubing port for dehumidification Applicable tubing I.D.: ø19 (NPT threads: ø3/4 inch)

28 Membrane Air Dryer Unit Type Series IDG Units (Type M, Type V) IDG 3 How to Order M 3 Symbol M V Contents Description Component equipment IDG3 to IDG5 IDG3H to IDG5H IDG3L, IDG5L IDG6 to IDG1 IDG6H to IDG1H IDG6L to IDG1L IDG6S to IDG1S IDG3 to IDG5 IDG3H to IDG5H IDG3L, IDG5L IDG6 to IDG1 IDG6H to IDG1H IDG6L to IDG1L Size Standard dew point temperature and air flow rate Symbol Standard dew point ( C) Nil 2 /6 5/12 1/2 2/5 3/7 5/12 6/12 75/15 1/19 H 15 /3 5/6 1/1 2/2 3/3 5/6 6/6 75/8 1/11 L 4 75/2 11/4 17/5 24/8 3/1 S 6 5/27 1/5 15/85 With separator With separator regulator Flow rate by size Outlet air flow rate Purge air flow rate (l/min(anr)) Mist separator Micro mist separator Micro mist separator with pre-filter Membrane air dryer IDG6S to IDG1S Note 1) Element service indicator is also available. Refer to Made to Order Specifications on page Note 2) Specifications with micro mist separator is also available. Refer to Made to Order Specifications on page (1) (2) Regulator Symbol Nil C Note) D Note) ( without valve) For the model selection of an auto-drain, refer to Selection 4 of Precautions on page Note) When the symbol C or D is designated, the same part number of an auto-drain listed on page will come together. Port size Symbol Bore 1 1/8 2 1/4 3 3/8 Option Size Symbol Contents Nil Standard (1) (2) (2) (2) (2) P With fitting for purge air discharge Flow direction R (Right Left) S With dew point indicator Standard equipment In the case of two or more options, indicate them alphabetically. Note 1) Symbol P is only applicable for Type M with either auto-drain or drain-guide. Type V is not applicable because it is equipped with a relief type regulator. (Symbol P is used when it is undesirable for the air to be discharged into the main body of IDG. Therefore, it is not possible to use it in combination with a separator with manual valve, which discharges air around it, or Type V with a relief type regulator.) Note 2) They are not applicable in case the thread type is N or F. (Because barrel nipples are used for equipment connections.) discharge method (Mist separator, Micro mist separator, Micro mist separator with prefilter) Size and standard dew point discharge 6, 6H 6L, 6S 3, 3H 1, 1H 3, 3H, 3L method 75, 75H 75L, 75S 5, 5H 2, 2H 5, 5H, 5L 1, 1H 1L, 1S Manual valve N.C. auto-drain auto-drain N.O. guide J Bore 1/4 3 Size Note) 1 Note) 4 1/2 Note) Not applicable with the cases of standard dew point 2 C (Nil), 15 C (symbol H). Thread type Nil N F Rc NPT G

29 Membrane Air Dryer Unit Type Series IDG Standard Specifications/Unit (Type M, Type V) [Standard dew point: 2 C] Component equipment Range of operating conditions Standard performance Standard performance conditions Standard dew point: 2 C IDG3M IDG5M IDG1M IDG2M IDG3M IDG5M IDG6M IDG75M IDG1M IDG3V IDG5V IDG1V IDG2V IDG3V IDG5V IDG6V IDG75V IDG1V Mist separator AFM2 AFM3 AFM4 Micro mist separator AFD2 AFD3 AFD4 Micro mist separator with prefilter AMH35 AMH45 Regulator (Type V only) (1) AR2(2) AR (2) AR4 (2) Fluid Compressed air Inlet air pressure (MPa).3 to.85.3 to 1. Inlet air temperature ( C) 5 to 55 (3) 5 to 5 (3) 5 to 5 Ambient temperature ( C) 5 to 55 5 to 5 5 to 5 Outlet air atmospheric pressure dew point ( C) 2 Inlet air flow rate (l/min (ANR)) (4) Outlet air flow rate (l/min (ANR)) Purge air flow rate (l/min (ANR)) (5) Inlet air pressure (MPa) Inlet air temperature ( C) Inlet air saturation temperature ( C) Ambient temperature ( C) Dew point indicator purge air flow rate Regulator construction (Type V only) Port size (Nominal size B) Weight (kg) (With auto-drain) Type M Type V (1.35) l/min (ANR) {In the case of Inlet air pressure.7 MPa} Relief type 1/8, 1/4 1/4, 3/8 3/8, 1/2 1/ (.9) (1.3) (1.53) (2.33) (2.36) (2.65) (3.2) (3.) 1.67 (1.76) Note 1) For flow characteristics and pressure characteristics of regulator, refer to page Note 2) It will come with Option E (With square-shaped, embedded type of a pressure regulator). For details on regulators, refer to pages to Note 3) No freezing. Note 4) ANR indicates the flow rate converted to the value at 2 C under the atmospheric pressure and the state of relative humidity 65%. Note 5) Includes 1 l/min (ANR) of purge air flow (at.7 MPa inlet air pressure) for the dew point indicator (except IDG3M/3V/5M/5V). Note 6) When highly purified air is required, refer to Caution on Design on page (1.99) 3.34 (3.45) 3.37 (3.48) 3.74 (3.84) 4.29 (4.39) 4.34 (4.44) JIS Symbol (Type M) IDG3M to 5M (Type V) IDG3V to 5V IDG6M IDG1V IDG3V Mist separator Micro mist separator Micro mist separator with prefilter Membrane air dryer IDG6M to 1M Membrane air dryer Auto-drain, Bowl Assembly, Pressure Gauge Part No. Mist separator Micro mist separator Micro mist separator with prefilter Membrane air dryer Regulator IDG6V to 1V Membrane air dryer Regulator Applicable models IDG3M IDG5M IDG1M IDG2M IDG3M IDG5M IDG6M IDG75M IDG1M Description IDG3V IDG5V IDG1V IDG2V IDG3V IDG5V IDG6V IDG75V IDG1V Float type N.C. AD27 AD37 AD47 auto-drain N.O. AD48 Bowl assembly (N.O.) AMH-CA35-D AMH-CA45-D Pressure gauge (Type V only) GC3-1 HA AT ID AMG AFF AM Misc. Replacement Parts (Mist separator, Micro mist separator, Element for micro mist separator with prefilter) Description AFM2 AFD2 AFM3 AFD3 AFM4 Element assembly Please refer to pages to for the replacement parts of a membrane air dryer. For flow characteristics, refer to pages to , and for external dimensions, refer to pages to AFD AMH35 AMH-EL35 AMH45 AMH-EL

30 Series IDG Standard Specifications/Unit (Type M, Type V) [Standard dew point: 15 C] Component equipment Range of operating conditions Standard performance Standard performance conditions Standard dew point: 15 C IDG3HM IDG5HM IDG1HM IDG2HM IDG3HM IDG5HM IDG6HM IDG75HM IDG1HM IDG3HV IDG5HV IDG1HV IDG2HV IDG3HV IDG5HV IDG6HV IDG75HV IDG1HV Mist separator AFM2 AFM3 AFM4 Micro mist separator AFD2 AFD3 AFD4 Micro mist separator with prefilter AMH35 AMH45 Regulator (Type V only) (1) AR2(2) AR (2) AR4 (2) Fluid Compressed air Inlet air pressure (MPa).3 to.85.3 to 1. Inlet air temperature ( C) 5 to 55 (3) 5 to 5 (3) 5 to 5 Ambient temperature ( C) 5 to 55 5 to 5 5 to 5 Outlet air atmospheric pressure dew point ( C) 15 Inlet air flow rate (l /min (ANR)) (4) Outlet air flow rate (l /min (ANR)) Purge air flow rate (l /min (ANR)) (5) Inlet air pressure (MPa) Inlet air temperature ( C) Inlet air saturation temperature ( C) Ambient temperature ( C) Dew point indicator purge air flow rate Regulator construction (Type V only) Port size (Nominal size B) Weight (kg) (With auto-drain) Type M Type V (1.35) l/min (ANR) {In the case of Inlet air pressure.7 MPa} Relief type 1/8, 1/4 1/4, 3/8 3/8, 1/2 1/ (.9) (1.3) (1.53) (2.33) (2.36) (2.65) (3.2) (3.) 1.67 (1.76) 1.9 (1.99) 3.34 (3.45) 3.37 (3.48) 3.74 (3.84) 4.29 (4.39) Note 1) For flow characteristics and pressure characteristics of regulator, refer to page Note 2) It will come with Option E (With square-shaped, embedded type of a pressure regulator). For details on regulators, refer to pages to Note 3) No freezing. Note 4) ANR indicates the flow rate converted to the value at 2 C under the atmospheric pressure and the state of relative humidity 65%. Note 5) Includes 1 l/min (ANR) of purge air flow (at.7 MPa inlet air pressure) for the dew point indicator (except IDG3HM/3HV/5HM/5HV). Note 6) When highly purified air is required, refer to Caution on Design on page (4.44) JIS Symbol (Type M) IDG3HM to 5HM (Type V) IDG3HV to 5HV Mist separator Micro mist separator Membrane air dryer Mist separator Micro mist separator Membrane air dryer Regulator IDG6HM to 1HM IDG6HV to 1HV IDG1HV IDG3HV Micro mist separator with prefilter Membrane air dryer Micro mist separator with prefilter Membrane airdryer Regulator IDG6HM Auto-drain, Bowl Assembly, Pressure Gauge Part No. Applicable model IDG3HM IDG5HM IDG1HM IDG2HM IDG3HM IDG5HM IDG6HM IDG75HM IDG1HM Description IDG3HV IDG5HV IDG1HV IDG2HV IDG3HV IDG5HV IDG6HV IDG75HV IDG1HV Float type N.C. AD27 AD37 AD47 auto-drain N.O. AD48 Bowl assembly AMH-CA35-D AMH-CA45-D Pressure gauge (Type V only) GC3-1 Replacement Parts (Mist separator, Micro mist separator, Element for micro mist separator with prefilter) Description AFM2 AFD2 AFM3 AFD3 AFM4 Element assembly Refer to pages to for the replacement parts of a membrane air dryer. For flow characteristics, refer to pages to , and for external dimensions, refer to pages to AFD AMH35 AMH-EL35 AMH45 AMH-EL

31 Membrane Air Dryer Unit Type Series IDG Standard Specifications/Unit (Type M, Type V) [Standard dew point: 4 C] Component equipment Range of operating conditions Standard performance Standard performance conditions Mist separator Micro mist separator Regulator (Type V only) (1) Fluid Inlet air pressure (MPa) Inlet air temperature ( C) Ambient temperature ( C) Outlet air atmospheric pressure dew point ( C) Inlet air flow rate (l/min (ANR)) (4) Outlet air flow rate (l/min (ANR)) Purge air flow rate (l/min (ANR)) (5) Inlet air flow pressure (MPa) Inlet air temperature ( C) Inlet air saturation temperature ( C) Ambient temperature ( C) Dew point indicator purge air flow rate Regulator construction (Type V only) Port size (Nominal size B) Weight (kg) (With auto-drain) Type M Type V IDG3LM IDG5LM Standard dew point: 4 C IDG6LM IDG75LM IDG1LM IDG3LV IDG5LV IDG6LV IDG75LV IDG1LV AFM4 AFD4 AR4 (2) Compressed air.3 to 1. 5 to 5 (3) 5 to (2.33) 3.34 (3.45).7 1 l/min (ANR) {In the case of Inlet air pressure.7 MPa} Relief type 1/4, 3/8 3/8, 1/ (2.36) (3.9) (3.24) 3.37 (3.48) 4.1 (4.2) 4. (4.35) Note 1) For flow characteristics and pressure characteristics of regulator, refer to page Note 2) It will come with Option E (With square-shaped, embedded type of a pressure regulator). For details on regulators, refer to pages to Note 3) No freezing Note 4) ANR indicates the flow rate converted to the value at 2 C under the atmospheric pressure and the state of relative humidity 65%. Note 5) Includes 1 l/min (ANR) of purge air flow (at.7 MPa inlet air pressure) for the dew point indicator. Note 6) When highly purified air is required, refer to Caution on Design on page (3.39) 4.4 (4.5) JIS Symbol (Type M) (Type V) IDG3LV Mist separator Micro mist separator Membrane air dryer Mist separator Auto-drain, Pressure Gauge Part No. Description Float type auto-drain Pressure gauge Applicable model IDG3LM IDG3LV IDG5LM IDG5LV Micro mist separator IDG6LM IDG6LV AD47 AD48 GC3-1 Membrane airdryer IDG75LM IDG75LV Replacement Parts (Mist separator, Element for micro mist separator) Description Element assembly IDG6LV IDG6LM Refer to pages to for the replacement parts of a membrane air dryer. For flow characteristics, refer to pages to for external dimensions, refer to pages , 43, 45, and 47. N.C. N.O. AFM4 AFD4 Regulator IDG1LM IDG1LV HA AT ID AMG AFF AM Misc

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500 Membrane Air Dryer RoS New Possible to easily supply dry air using the hollow fiber membrane! Non-fluorocarbon Compatible with low dew point ( 6C) No vibration or heat discharge Purge air flow rate (L/min

More information

Cost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500.

Cost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500. Membrane Air Dryer A/ RoS Possible to easily supply dry air using the hollow fiber membrane! AT Non-fluorocarbon Compatible with low dew point ( 6 C) No vibration or heat discharge Purge air flow rate

More information

Cost reduced by up to /year! Purge air flow rate (rated conditions) Running cost [ /year] Model IDG50A

Cost reduced by up to /year! Purge air flow rate (rated conditions) Running cost [ /year] Model IDG50A embrane Air Dryer Possible to easily supply dry air using the hollow fiber membrane! Non-fluorocarbon Compatible with low dew point ( 6 C) RoHS No vibration or heat discharge New Energy saving in air flow

More information

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500 embrane Air Dryer Possible to easily supply dry air using the hollow fiber membrane! Purge air flow rate (L/min [ANR]) 18 16 14 12 8 6 4 IDGA..5 1. Variations Non-fluorocarbon Energy saving IDGA Inlet

More information

Membrane Air Dryer IDG10,IDG10H IDG20,IDG20H

Membrane Air Dryer IDG10,IDG10H IDG20,IDG20H Doc. No. AMX-OM-Q013 PRODUCT NAME Membrane Air Dryer MODEL / Series / Product Number IDG10,IDG10H IDG20,IDG20H Contents 1. Safety Instructions 1 2. Installations and Operations 3 3. Maintenances and Checks

More information

MEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS

MEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Features, Dehumidification Principles, Order Codes 209 Specifications, Dimensions 210 Dry Air Flow Rate,

More information

Membrane Air Dryer IDG30 A IDG50 A IDG60LA,IDG60SA IDG75LA,IDG75SA IDG100LA,IDG100SA

Membrane Air Dryer IDG30 A IDG50 A IDG60LA,IDG60SA IDG75LA,IDG75SA IDG100LA,IDG100SA Doc. No. AMX-OM-Q014 PRODUCT NAME Membrane Air Dryer MODEL / Series / Product Number IDG30 A IDG50 A IDG60LA,IDG60SA IDG75LA,IDG75SA IDG100LA,IDG100SA Contents 1. Safety Instructions 1 2. Installations

More information

% by up ctoond re-heater and

% by up ctoond re-heater and Refrigerated Air Dryer 100FS/125FS/150FS Series Saves energy 76 % by up ctoond re-heater and Digital scroll compressor Stainless steel heat exchanger Ozone depletion potential ZERO refrigerant RoHS HAA

More information

TUBE DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution TUBE DRYERS

TUBE DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution TUBE DRYERS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Features 197 Safety Precautions 199 Secondary Air Flow Rate, Secondary Air Dew Point, and Pressure Drop 201

More information

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT Refrigerating Desiccant High polymer membrane dryer VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT JIS symbol Air filter Auto. drain (Module unit) (Separate) Compact Precise (Related

More information

AMG Model (1) Port size (Nominal size B) Weight (kg) 1 /8, 1 /4, 3 /8 1 /4, 3 /8, 1 /2 3 /8, 1 /2, 3 /4. Specifications

AMG Model (1) Port size (Nominal size B) Weight (kg) 1 /8, 1 /4, 3 /8 1 /4, 3 /8, 1 /2 3 /8, 1 /2, 3 /4. Specifications Water Separator Series The series water separator is installed on the air pressure line to remove water drops in the compressed air. It is suitable for use in cases where "water must be removed, but the

More information

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C) Refrigerated ir ryer Series IF For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor,

More information

Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting

Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting http://www.pisco.co.jp PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting Fiber Dry Series 188 Hollow Fiber Membrane Filter Type

More information

Vacuum Saving Valve. ZP2V Series. With One-touch fitting type available!

Vacuum Saving Valve. ZP2V Series. With One-touch fitting type available! Vacuum Saving Valve Series Can restrict the reduction of vacuum pressure even when there is no workpiece. When multiple vacuum pads are operated by one vacuum generator, and some of them are not holding

More information

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm) http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made

More information

Hollow Fiber Membrane Filter Type Air Drier Unit Type

Hollow Fiber Membrane Filter Type Air Drier Unit Type http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Hollow Fiber Membrane Filter Type Air Drier Unit Type Dry Unit 202 No electric power supply is required. Air Filter, Mist

More information

UltraDry s Features and Benefits

UltraDry s Features and Benefits pneuaire UltraDry s...........................................3-5 Features and Benefits..............................................................................3 How to Order....................................................................................4

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated ir ryer Series For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and

More information

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm) http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made

More information

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V Refrigerant R7 0, 0 90 I ir compressor Refrigerant 0kW kw 90kW kw Refrigerant R 70 I Refrigerant R7, R Series I Large 0,, 90,, 70 0 90 R7 Size 70 7 9 0 90 Three Voltage 7 9 Voltage 00/00 to 0V (/Hz) 0V

More information

Moisture Control Tube

Moisture Control Tube Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) -80 www.cmafh.com Moisture Control Tube (Moiscon) Prevents! Prevents condensation in piping for small cylinders/air

More information

Prevents! Moisture Control Tube. Diffuses water vapor in the piping to the outside! Series IDK

Prevents! Moisture Control Tube. Diffuses water vapor in the piping to the outside! Series IDK Moisture Control Tube Prevents! Prevents condensation in piping for small cylinders/air grippers. Diffuses water vapor in the piping to the outside! vapor Moisture control tube vapor All you have to do

More information

Refrigerated Air Dryer

Refrigerated Air Dryer T.S30-8 Refrigerated ir ryer Series IF/IU ir flow capacity Power consumption Refrigerant Increased up to the max. 40% ecreased up to the max. 40% F34a oefficient of destruction for ozone is zero. Improved

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir ryers Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment

More information

Reducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable.

Reducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable. http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Reducing Valve Direct Mount Type with Pressure Gauge 232 Direct Mount Type (Compact size) Pressure Gauge is selectable. Display

More information

P3X Series Membrane dryers

P3X Series Membrane dryers aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding P3X Series Membrane dryers Catalogue no. PDE2640TCUK - April 2010 WARNING

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated ir ryer E/F Series For use in Europe, sia and Oceania Standard/ E Series H HW Power supply voltage: Single-phase 230 V (50Hz) 3E 4E 6E 8E 11E 15E1 22E 37E 55E 75E ir flow capacity (m3/h [NR])

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir Dryers Protect Pneumatic Equipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated Air Dryer For Use in Southeast Asia Applicable for the high-temperature environments of tropical regions Can be used in high-temperature environments Ambient temperature : Max. 45 C Inlet

More information

High Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value

High Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value High Inlet Temperature Air Dryer Membrane Air Dryer After-Clooler Oil-Water Separator Automatic Value 1 2 3 4 5 6 7 8 9 1 HYD model Control Panel 1. on HYD-150 and smaller - It is equipped with a low pressure

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated Air Dryer For Use in Europe, Asia and Oceania Applicable for the high-temperature environments Ambient temperature : Max. 45 C Inlet air temperature : Max. 65 C Air flow capacity * IDFA90-23,

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated Air Dryer Applicable for the high-temperature environments Ambient temperature : Max. 45 C Inlet air temperature : Max. 65 C Air flow capacity * IDF90-20, Dew point of 10 C, 60 Hz 16.4 m 3

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir Dryers Series F/U Standard/High Temperature ir Inlet Type Protect Pneumatic Equipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor,

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir ryers /IU Series Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic

More information

Filter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size).

Filter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size). http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Redcing Valve with Built-in Filter Filter Regulator 238 Filter for Drain and Dust (Filtering Accuracy: 5µm) Plastic made Bowl

More information

CKD refrigerating type dryer

CKD refrigerating type dryer CKD refrigerating type dryer GT9000 Applicable air compressor: 90, 120, 1, 190, 240, 300, 380, 4, 710, 960kW Components for air preparation and pressure adjustment / main line unit / refrigerating type

More information

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS The Most Advanced Technologies for High-Quality air High-precision processing technology is required to produce the components that make up a Scroll Compressor.

More information

16 mm. Ionizer Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10

16 mm. Ionizer Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10 Ionizer Nozzle type Series IZN10 Electrode needle contamination detector Outputs maintenance signal when detects stain or wear of an electrode needle always. Detects optimal maintenance time, reduced labor

More information

13-1. Temperature Regulator

13-1. Temperature Regulator -1 Step 0 Type/Structure/Features Please refer to this for type, structure and features of. Step 1 Selection Please look at the ID chart to choose the right products depending on the intended uses. Details

More information

Pressure Switches Precautions 1 Be sure to read this before handling.

Pressure Switches Precautions 1 Be sure to read this before handling. Pressure Switches Precautions 1 Design / Selection 1. Confirm the specifications. Products represented in this catalog are designed ony for use in compressed air systems (including vacuum). Do not operate

More information

BULLETIN: APPL-QAF-133R1

BULLETIN: APPL-QAF-133R1 BULLETIN: APPL-QAF-133R1 DEW DILIGENCE MEMBRANE DRYERS A Proven Technology That Increases Equipment Reliability Membrane air drying technology has been proven to make it easier and less expensive to provide

More information

Compressed air preparation Compressed air storage Moisture management. Catalog #1

Compressed air preparation Compressed air storage Moisture management. Catalog #1 Compressed air preparation Compressed air storage Moisture management Catalog #1 This Catalogue is valid from May 2015. All previous catalogues lose their validity with the publication of the new catalogue.

More information

Treatment. Compressed Air. Equipment CONTENTS

Treatment. Compressed Air. Equipment CONTENTS Compressed Air Treatment Equipment CONTENTS 01 REFRIGERATED AIR DRYER P01 02 DESICCANT AIR DRYER P03 03 COMBINED TYPE AIR DRYER P05 04 OIL REMOVER P05 05 COMPRESSED AIR FILTERS P06 06 AIR RECEIVER TANK

More information

Drain Separator for Vacuum

Drain Separator for Vacuum Separator for Vacuum Series M emoves water droplets from air by simply installing in vacuum lines. Prevents damage of vacuum pumps and ejectors. Ejector Z Z Z M MV EP elated separator for vacuum side port

More information

Refrigeration air dryer

Refrigeration air dryer Principle of refrigeration air dryer Pneumatic circuit (System diagram) Warm wet water is precooled by compressed air chilled and dehumidified by air balancer (A) (precooler). Precooled compressed air

More information

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation Filtration Balston Membrane Nitrogen Generators Compressed Air Dryers 157 Parker Hannifin Corporation Membrane Air Dryers Provide Clean, Dry Compressed Air Offer a reliable, efficient, and economical alternative

More information

Noiseless Heater Vacuum Relief Valve

Noiseless Heater Vacuum Relief Valve Noiseless Heater Vacuum Relief Valve -1 Step Type/Structure/Features Please refer to this for structure and feature of Noiseless Heater and Vacuum Relief valve. Step 1 Selection Please look at the ID chart

More information

Radiator Trap Radiator Valve

Radiator Trap Radiator Valve Radiator Trap Radiator Valve -1 Step 0 Type/Structure/Features Please refer to this for structure and features of Radiator Trap, Radiator Valve, and Cold & Hot Water Valve. Oventrop GmbH & Co. KG For products

More information

Prevents condensation

Prevents condensation Moisture Control Tube Series Prevents condensation in piping for small cylinders/air grippers. Diffuses water vapor in the piping to the outside! Water vapor dditional power supply and works are not necessary!

More information

Chapter 9: The basics of air preparation

Chapter 9: The basics of air preparation Right of authorship: the content of the training (wording, drawings, pictures) are owned by the author. Any utilization except for individual use is allowed only after permission of the author. Compressed

More information

Disc Type Steam Trap TSD-42

Disc Type Steam Trap TSD-42 Disc Type TSD-42 TSD-42 is disc type steam trap for high pressure (maximum pressure: 4.2 MPa). It is compact and lightweight, and can be installed horizontally or vertically. Disc Ring By-Metal Valve seat

More information

Specifications. The Liquid Super Separator is a new concept of air filtration that is totally different from

Specifications. The Liquid Super Separator is a new concept of air filtration that is totally different from Nex Flow Introduces The New Super Separator removes 99.9% oil and water "guaranteed" with near zero maintenance (no replaceable filter elements) and has a 5 year warranty! Specifications New concept NO

More information

Refrigerated Air Dryers VF Series. DHT Series. Non-Cycling 10-2,000 scfm scfm

Refrigerated Air Dryers VF Series. DHT Series. Non-Cycling 10-2,000 scfm scfm Refrigerated Air Dryers VF Series Non-Cycling 10-2,000 scfm DHT Series Front High Inlet Page Temperature 20-125 scfm 1 VF Series Non-Cycling Refrigerated Air Dryer 10-2,000 scfm Since 1994, Aircel has

More information

Adsorption dryers PDAD

Adsorption dryers PDAD Key features Description Areas of application Features/Advantages/Benefits Cold-regenerating adsorption dryer with defined pressure dew point and high flow rate for decentralised compressed air drying

More information

CMMD Series Membrane Air Dryer

CMMD Series Membrane Air Dryer CMMD Series Membrane Air Dryer NEW Engineered to Save CMMD Series Compressed Air Dry Air Membrane Drying CompAir s CMMD Series membrane air dryer offers a pointofuse alternative for low dew point applications

More information

Owners Manual Refrigerated Air Dryer MHT SERIES

Owners Manual Refrigerated Air Dryer MHT SERIES Owners Manual Refrigerated Air Dryer MHT SERIES IMPORTANT: READ THIS MANUAL CAREFULLY. IT CONTAINS IN- FORMATION ABOUT SAFETY AND THE SAFETY OF OTHERS. ALSO BECOME FAMILAR WITH THE PROPER INSTALLATION

More information

Waveguide Dehydrators

Waveguide Dehydrators Waveguide Dehydrators Clean & Dry Air For Clear Communications Rugged & Reliable Compressed Air Systems for: TV and Radio Broadcast Applications Satellite Radar Aerospace Telecommunications Military Custom

More information

KITZ MICRO FILTER PRODUCTS CATALOG R GUN G R DRYER

KITZ MICRO FILTER PRODUCTS CATALOG R GUN G R DRYER KITZ MICRO FILTER PRODUCTS CATALOG AIR A I R GUN G U N AIR A I R GUN G U N PP P P INLINE I N L I N E FILTER F I L T E R WATER W A T E R GUN G U N AIR A I R DRYER D R Y E R About hollow fiber membrane About

More information

SYNRAD Technical Bulletin # 0015d

SYNRAD Technical Bulletin # 0015d Page 1 of 6 SYNRAD Technical Bulletin # 0015d Technical Issue: Purge Gas Conditioning for f201/f400, i401, & p100/p250 Lasers Date: 30 July 2014 Description: This Technical Bulletin describes how to prevent

More information

industry revolves around VMMD Series Membrane Air Dryer

industry revolves around VMMD Series Membrane Air Dryer industry revolves around VMMD Series Membrane Air Dryer VMMD Series Membrane Drying VMMD Series membrane air dryer offers a pointofuse alternative for low dew point applications ( F) by using membrane

More information

Refrigerated Air Dryer Large Size Series

Refrigerated Air Dryer Large Size Series Refrigerated ir Dryer Large Size Series E Directive compliant (with E marking) For use in Europe, sia and Oceania Power Three-phase 380 V (For sia and Oceania) supply voltage Three-phase 400 V (For Europe)

More information

HL Hydraulik GmbH SCHRUPP GAS DRYER STATIONS GAS DRYER STATIONS. Optional with Bypass.

HL Hydraulik GmbH SCHRUPP GAS DRYER STATIONS GAS DRYER STATIONS. Optional with Bypass. SCHUPP GAS DYE STATIONS SCHUPP GAS DYE STATIONS Optional with Bypass For compressed Air and other non- aggressive gaseous media: - drying - de-oiling - filtering this means - less corrosion - less wear

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC AQB09JJ6WC_IM_E_2585 2006.4.17 4:26 PM Page 17 INSTALLATION MANUAL Indoor Unit AQB09JJWC AQB12JJWC Outdoor Unit UQB09JJWC UQB12JJWC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

LEVEL SENSED DRAINS KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP 50 KAPTIV-CS-HP 500 NUFORS-CR MAGY-UL

LEVEL SENSED DRAINS KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP 50 KAPTIV-CS-HP 500 NUFORS-CR MAGY-UL KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP 50 KAPTIV-CS-HP 500 NUFORS-CR MAGY-UL ENVIRONMENT DRAIN EFFICIENCY SAFEGUARD RELIABLE COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS LEVEL SENSED DRAINS

More information

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL H-Series & 203 THRU 223 SERIES ARROW PNEUMATICS, INC. REGENERATIVE DRYER DIVISION 2111 WEST 21ST STREET BROADVIEW, IL 60155 708-343-9595 708-343-1907

More information

Model FDT FDT A FDT FDT A FDT FDT A FDT FDT A. Model DMP DMP DMP DMP

Model FDT FDT A FDT FDT A FDT FDT A FDT FDT A. Model DMP DMP DMP DMP ontrol Series Fiber Dry FDT Dry unit (Filter, ) L 2 2 2 2 φ 25.5 (M5 Attachment) L2 5 2 27 3 22.5 7 FDT FDT A FDT FDT A FDT FDT A FDT FDT A L L2 9.5 2.5 2.5 9 7 2.5.5 22 2 3 3 9 9 DMP 3 22.5 25.5 (M5 Attachment)

More information

GHP OUTDOOR UNIT INSTALLATION INSTRUCTIONS E1 Combination Multi Type

GHP OUTDOOR UNIT INSTALLATION INSTRUCTIONS E1 Combination Multi Type 621471-20E32 EN Always read before installation. Aisin Gas Heat Pump Air Conditioner GHP OUTDOOR UNIT INSTALLATION INSTRUCTIONS E1 Combination Multi Type Standard - Renewal [Model P450 - P560 - P710] Applicable

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated Air Dryer Large Size Series Tolerant of high temperature environment! Top of its class in the industry for the large air-cooled type Ambient temperature 45 Inlet air temperature 60 Energy

More information

Low dew point type. Discrete standard dew point type (SD3015-B) (SD3035-B) (SD3050-B) (SD3075/4050-B) (SD4075-B) (SD4100-B) (SD3015-A)

Low dew point type. Discrete standard dew point type (SD3015-B) (SD3035-B) (SD3050-B) (SD3075/4050-B) (SD4075-B) (SD4100-B) (SD3015-A) Pressure Series variation Series Features Applicable compressor kw 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 22 37 55 75 95 120 150 200 250 300 400 480 710 960 1450 With common exhaust port Medium pressure

More information

Membrane Technologies DMD Series Dryers ESM Series Dryers

Membrane Technologies DMD Series Dryers ESM Series Dryers Membrane Technologies DMD Series Dryers ESM Series Dryers Membrane Technologies Energy Saving Compressed Air Dryers People around the globe have relied on Deltech to deliver energy efficiency and value

More information

Membrane Dryers KMM Series

Membrane Dryers KMM Series www.kaeser.com Membrane Dryers KMM Series Flow volume at inlet up to. m /min Why is it necessary to dry compressed air? The atmospheric air drawn into a compressor is a mixture of gases that always contains

More information

Ioniser Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10

Ioniser Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10 Ioniser Nozzle type Dust removal and static electricity elimination by air blow Eliminates dust clinging to lamp covers. Spot type static electricity elimination Prevents electrostatic breakdown of electric

More information

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS INSTRUCTION MANUAL FOR WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS DE3 - DE5 OPERATIONS GENERAL This instruction manual covers the installation, operation, maintenance and troubleshooting

More information

Valve timing. Atmospheric air

Valve timing. Atmospheric air 31.5-mm wide vacuum unit is designed to optimize the control of large vacuum flows. Vacuum generator and External vacuum controller are available for various needs. Three different types of vacuum generator

More information

Complex Vacuum Generator realizing Stable and High-Speed Response Vacuum Generator VN Series

Complex Vacuum Generator realizing Stable and High-Speed Response Vacuum Generator VN Series EXTERNAL GENERATOR CONTROLLER PAD ACCESSORIES Complex Vacuum Generator realizing Stable and High-Speed Response Vacuum Generator Series 282 Suitable for semiconductor industry such as IC chip loader or

More information

INVERTER SPLIT - TYPE

INVERTER SPLIT - TYPE INVERTER SPLIT - TYPE ISSUE No 2 DATE 04/09/08 P/No 2020323A2868 CONTENTS SAFETY PRECAUTIONS Warning 2 Operating temperature 2 BEFORE INSTALLATION Tools needed for installation 3 Items required for installing

More information

VarioDry SPN

VarioDry SPN Dryer VarioDry Technologies SPN 0003-0063 Membrane Air Dryers VarioDry SPN 0003-0063 MAIN FEATURES & BENEFITS: Very low purge air Lightweight design Nine types with 3,0 up to 63 Dew point reduction down

More information

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138 7428146 Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138 1.0 SAFETY All compressed gases, including air, can be dangerous.

More information

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax A R R O W P N E U M A T I C S Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca. 93308 661-399-9569 fax 661-393-9654 F I L T E R S R E G U L A T O R S L U B R I C A T O R S A C C E S S O R I E S H E

More information

SECTION air supply system + WARNING: + NOTE: GENERAL DESCRIPTION COMPRESSED AIR RESERVOIRS / 1.

SECTION air supply system + WARNING: + NOTE: GENERAL DESCRIPTION COMPRESSED AIR RESERVOIRS / 1. 08-000.02/ 1 2011JA14 SECTION 08-000.02 GENERAL DESCRIPTION See Figure 1 for a schematic diagram of the. See the Nova LFS parts manual for a detailed schematic of the. The function of the vehicle s is

More information

Vacuum system component SELVACS

Vacuum system component SELVACS Vacuum system component SELVACS Vacuum related components CC-796A 1 Wide variations for an assortment of applications New SELVACS vacuum components respond to a wide range of applications from fine work

More information

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series Features This 1.5 mm width vacuum unit is ideal for controlling large flow rates. A vacuum ejector unit and vacuum switching

More information

Prevents condensation

Prevents condensation Moisture Control Tube Prevents condensation in piping for small cylinders/air grippers. Diffuses water vapor in the piping to the outside! Water vapor Linear shape Suitable for applications where cylinders

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC AQB8J6WC_IM_E_25864 2006.4.4 3:29 PM Page 7 INSTALLATION MANUAL Indoor Unit AQB8J6WC AQB24J2WC Outdoor Unit UQB8J6WC UQB24J2WC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

Membrane Dryers KMM Series

Membrane Dryers KMM Series www.kaeser.com Membrane Dryers KMM Series Flow volume at inlet up to.0 m /min Why is it necessary to dry compressed air? The atmospheric air drawn into a compressor is a mixture of gases that always contains

More information

Product Data Sheet Refrigeration Dryer DFX

Product Data Sheet Refrigeration Dryer DFX Version: 1.0.6 Author: Tassilo Tappe Date: 10.07.2012 Field of application Refrigeration dryers of the DFX series are designed for drying compressed air flows up to 14 bar(g) / 16 bar(g) to pressure dew

More information

Membrane air dryers MS-LDM1, MS series

Membrane air dryers MS-LDM1, MS series Membrane air dryers MS-LDM1, MS series Membrane air dryers MS-LDM1, MS series Product range overview MS series service units Type Size Pressure regulation range [bar] Grade of filtration [μm] Pneumatic

More information

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO AOYG8LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL For authorized service personnel only. English PART NO. 93778639 93778639_IM.indb /20/20 6:07:25 PM AIR CONDITIONER OUTDOOR UNIT INSTALLATION

More information

ThermoStar Refrigeration Air Dryers

ThermoStar Refrigeration Air Dryers ThermoStar Refrigeration Air Dryers Why Dry Compressed Air? Contamination Reduces Efficiency The air we breathe contains contamination in the form of water vapor and airborne particles. These problems

More information

Product Data Sheet Adsorption Dryer DPS (A)

Product Data Sheet Adsorption Dryer DPS (A) Version: 1.0.5 Author: Tassilo Tappe Date:13.07.2012 Field of application Adsorption dryers of the DPS series are designed for drying compressed air and nitrogen to pressure dew points of -25 C to -70

More information

MDH Series Air Dryer. User s Guide

MDH Series Air Dryer. User s Guide MDH Series Air Dryer User s Guide Models covered: MDH1 MDH2 MDH3 MDH4 MDH5 MDH6 1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS MDH SERIES AIR DRYER! We here at PUREGAS

More information

standard response/ quick response extended coverage

standard response/ quick response extended coverage 1. DESCRIPTION Viking Extended Coverage Adjustable Recessed Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry

More information

KINNEY OIL MIST ELIMINATORS

KINNEY OIL MIST ELIMINATORS KINNEY OIL MIST ELIMINATORS Models: A B, B1 & B2 C1 D & D1 Instruction Manual 1855-1 Revision 12/01 TABLE OF CONTENTS DESCRIPTION... 1 OPERATION... 1 ELEMENTS... 2 OIL RETURN METHODS... 3 DIRECT DRAIN

More information

Product Data Sheet Adsorption Dryer DPS

Product Data Sheet Adsorption Dryer DPS Version: 1.6.0 Author: Tassilo Tappe Date : 05.07.2016 Field of application Adsorption dryers of the DPS series are designed for drying compressed air and nitrogen to pressure dew points of -25 C to -70

More information

ZERO AIR GENERATOR MODEL 7000 INSTRUCTION MANUAL

ZERO AIR GENERATOR MODEL 7000 INSTRUCTION MANUAL ZERO AIR GENERATOR MODEL 7000 INSTRUCTION MANUAL UNPACKING Connect the intake filter to the Air In port as shown below. Use Teflon tape on filter thread if not supplied on the fitting. POWER The ZAG is

More information

Air Saver Unit. The power saving and CO 2 reduction products

Air Saver Unit. The power saving and CO 2 reduction products Air Saver Unit The power saving and CO 2 reduction products An easy solution to your environmental protection efforts! The air saving unit contributes to power savings and CO2 reduction. 50% LESS When

More information

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Owner s Manual Refrigerated Compressed Air Dryers Model F-100 Owner s Manual Refrigerated Compressed Air Dryers Model F-100 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing

More information

Adsorption Compressed Air Dryer Heatless or heater regeneration

Adsorption Compressed Air Dryer Heatless or heater regeneration Adsorption Compressed Air Dryer Heatless or heater regeneration What s adsorption? Drying with high efficiency and economy Some compressed air applications requests a low moisture level (dew point between

More information

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE -

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE - HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE - Nominal Cooling Capacity Range 112 kw to 1,080 kw at 50Hz 32 USRT to 307 USRT at 50Hz 96,320 kcal/h to 928,800 kcal/h at 50Hz 382,000 Btu/h to 3,685,000

More information

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual DRRRRDRY-PAK Instruction and Installation Manual IB-160 Rev. B P/N 36595 Registered by UL to ISO 9001 DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual INSTALLATION: Models DS0-00-000 through

More information