UNIT 5 COLD WATER SUPPLY

Size: px
Start display at page:

Download "UNIT 5 COLD WATER SUPPLY"

Transcription

1 UNIT 5 COLD WATER SUPPLY

2 Introduction These slides are intended to support tutor delivery of the Plumbing 6129 level 2 Technical Certificate and should be used in conjunction with the second edition of Plumbing by Steve Muscroft. The slides are based on each unit in the book, and are designed to provide samples for each topic area, they are not presented as a complete set of slides but as a starter for tutors to build up their own presentation package.

3 This unit covers: Cold water supply and treatment: Regulations Collection and storage of water Water distribution Water treatment Service and mains connection Requirements of service pipework Water meters Domestic cold water supply in domestic dwellings: Types of systems, direct and indirect Scale inhibitors and conditioners Requirements of cold water storage cisterns Frost protection

4 Physical forms of water

5 The rain cycle

6 Ferrule and goose neck

7 Details from the mains to the internal stop valve

8 Internal stop valve What s the yellow and cable for? What is the white substance above the compression nut on the stop valve?

9 Typical water meter

10 Internal stop valves Combined stop valve and drain tap

11 Water mains pressure Mains water pressure is measured in bars. Supply pressure is important because it needs to satisfy the demands of the consumer, as well meeting appliance specifications that require a minimum water pressure to enable them to operate to effectively, an example being instantaneous showers or water heaters. The operating pressures for such appliances should be included in the manufacturer s instructions. The Water Supplier is responsible for the water mains delivery pressure to the building, so if it s poor they would need to be advised.

12 Water flow rate can be measured at the tap by using a flow meter device called a weir gauge. Alternatively this can be carried out by using a container with a known capacity e.g. measuring beaker used for cooking, and with the tap full open timing how long it takes to fill the container and then calculating the flow rate per minute in litres per minute.

13 There are several different methods for reducing the build up of limescale in domestic plumbing systems, including: Base exchange softeners Electrolytic Scale Inhibitors Magnetic Scale Inhibitors Digital Electro Magnetic conditioners Magnetic Electrolytic

14 Water system types: Direct system

15 Water system types: Indirect system

16 Requirements for cold water storage cisterns (CWSC): The CWSC is a very important part of a domestic cold water system, and as such is well covered by the Water Regulations. The following illustration shows a CWSC that fully meets the Water Regulations requirements of Schedule 2: paragraph 16 (4) for cold water storage cisterns installations.

17 Cistern connections and control valves Portsmouth valve

18 Cistern connections and control valves Diaphragm valve

19 Cistern connections and control valves Diaphragm equilibrium float valve

20 Servicing valves Three different types of servicing valve where do you think each might be used?

21 Use of check valves The following list shows some typical applications where the Water Regulations require single and double check valves to be installed. Single check valves Connected prior to water softener Unvented heating systems Supply to wet sprinkler system Downstream of meters and pressure reducing valves (no specific regulation but essential for correct operation of equipment)

22 Use of check valves continued Double Check Valves Supply to hose taps Supply to standpipes Pipe connection to cisterns using part 1 float valves Supply to shower fitting Shower Check Valves Supply to shower spray head where shower hose pipe is unconstrained e.g.. air gap requirement cannot be guaranteed.

23 Warning and overflow pipes What is the purpose of a warning and overflow pipe?

24 Frost protection Requirements for suspended timber floors

25 Hose union bib tap and requirements for external stand pipe

26 Details of insulated cold water storage cistern

27 Activity 5.1 What do you think are the main objectives of the regulations? There are five listed in the regs, starting with preventing the contamination of a water supply. Write them down on separate sheets of paper and put them in your portfolio, you can find the answers in the book Muscroft Plumbing: Curriculum Support Pack: classroom handouts

28 Activity 5.2 Water can be found in three physical forms, what do you think they are? We ve given you one answer; jot down the other two in your portfolio. Check your answers in the book Liquid - as water. 3. Muscroft Plumbing: Curriculum Support Pack: classroom handouts

29 Case study Figure 5.5 Leslie has been asked to check that the installation in figure 5.5 is installed correctly. Leslie consults the regulations and makes the following notes as a cross check. The supply pipe or distributing pipe that s providing water to individual dwellings must be fitted with a conveniently located stop valve to enable the supply to be shut off. The minimum permitted size for a cold water service into a building is 15mm diameter. Where a cold water supply pipe enters a building via a duct, the pipe duct must be sealed at both ends; this is to prevent any gases or vermin entering the building. In order to protect against frost damage, mains and service pipes should be at least 750 mm beneath the surface of the ground. This is a requirement made under the Water Regulations Schedule 2, paragraph 7 (4) The maximum depth of cover over the pipe should not exceed metres, as this would prevent ease of access Metallic pipes, such as copper should be protected against possible corrosion from soil, particularly where acidic soils exist. This can be achieved by: - Using plastic coated pipe - Wrapping the pipe with a suitable protective wrapping - Installing the pipe inside a duct, sealing the ends of the duct on final completion. Muscroft Plumbing: Curriculum Support Pack: classroom handouts

30 Activity 5.3 Why not see if you can try and locate the external stop valve where you live? This is used to isolate the supply to a dwelling, and plumbers may be required to locate it. The stop valve within the box should be accessible, i.e. clean from debris etc. Just locate it; please don t do anything with it!! Muscroft Plumbing: Curriculum Support Pack: classroom handouts

31 Activity 5.4 Take a close look at the two diagrams and have another read of the text. Have a think about what the advantages and disadvantages might be for both systems. Jot down your thoughts on separate sheets of paper and include them in your portfolio. A suggested answer is in the book. Muscroft Plumbing: Curriculum Support Pack: classroom handouts

32 Activity 5.5 What do you think is the main advantage of fitting servicing valves? Write your answer on a separate sheet and include it in your portfolio before checking against the suggested answer in the book. Muscroft Plumbing: Curriculum Support Pack: classroom handouts

33 Case study Leslie has been called out to a job to check that a CWSC installation conforms to the water regulations. If the float operated valve becomes defective, the warning pipe must be capable of removing the excess water, preventing the valve from being submerged and the cistern from spilling over, so Leslie makes a note of the following points to check out. Warning pipes should have a minimum diameter of 19mm, or be a least one size larger than the inlet pipe. They must be fitted with a screen or filter to prevent insects or vermin getting in Warning/ overflow pipes must be constructed from rigid, corrosion resistant material. Flexible hose connections are not allowed to form part of the pipe. Warning pipes from central heating feed and expansion cisterns must be kept separate from those from cold water storage cisterns. Warning pipes must fall continuously from the cistern to the point of discharge. It s OK to joint two or more warning/ overflow pipes, from similar types of cisterns to form a common warning pipe, providing that the discharge is visible and that one cistern doesn t discharge into the other. Muscroft Plumbing: Curriculum Support Pack: classroom handouts

34 Activity 5.6 The illustration above shows an external stand pipe installation. Can you identify the key design features? Write down your findings for your portfolio and check them out in the book. Muscroft Plumbing: Curriculum Support Pack: classroom handouts

35 5.1 Test yourself 1. What regulations cover the requirements of the cold water supply to a domestic dwelling? 2. The regulations cover five main objectives, state one of these objectives. 3. When water freezes, by what percentage does it expand? 4. Which type of water is most likely to cause the build up of limescale in water systems when heated above C? 5. Name two underground sources from where water can be obtained. 6. Briefly describe what is meant by the term the rain cycle. Muscroft Plumbing: Curriculum Support Pack: classroom handouts

36 5.2 Test yourself 1. What are the minimum and maximum depth measurements for under ground water service pipes? 2. List the two methods of treatment used for reducing limescale in hard water areas 3. State two main purposes of stop valves and servicing valves on installation pipework. 4. Give two example of where a double check valves might be used 5. The paragraph below describes the difference between a direct and indirect cold water system, fill in the missing words. All the pipes to the draw off points (kitchen sink, bath, wash hand basin, wc, etc) in a..system are taken..from the.-.and operate under..pressure. With the.system, one outlet usually the kitchen sink is fed directly from the rising main, before it continues to supply the.. The remaining draw off points are fed from this source. 6. State two main forms of frost protection used on cold water installations. Muscroft Plumbing: Curriculum Support Pack: classroom handouts

37 Multi-choice end assessment Time available to complete all questions: 15 minutes Please tick the answer that you think is correct. 1. From which of the following would find the legal requirements for the installation of cold water services? a. British Standards b. Building Regulations c. Construction Regulations d. Water Regulations 2. What is the minimum depth for an underground cold water service pipe? a. 350mm b. 550mm c. 750mm d. 1350mm 3. What is the maximum depth of an underground cold water service pipe? a. 350mm b. 550mm c. 750mm d. 1350mm 4. Which of the following items of equipment would be used to determine that a cold water supply to a dwelling would be adequate to serve the plumbing appliances? a. Flow meter b. Water meter c. Manometer d. Pressure gauge 5. The most common use of type B compression fittings is: a. On internal cold water supply pipework b. To isolate float operated valves c. On Underground service pipework d. To drain down the CWSC 6. Drain taps on internal service pipework should be located: a. Immediately above the stop valve b. Immediately below the stop vale c. A minimum of 300mm above the stop valve d. A drain tap should not be fitted to the internal service pipe Muscroft Plumbing: Curriculum Support Pack: classroom handouts

38 7. The minimum capacity of an indirect cold water storage cistern in a domestic dwelling should be: a. 75 litres b. 115 litres c. 230 litres d. 415 litres 8. The minimum capacity of an direct cold water storage cistern in a domestic dwelling should be: a. 75 litres b. 115 litres c. 230 litres d. 415 litres 9. A weir gauge would be used to measure the: a. Water pressure at a tap b. Water flow rate at a tap c. Depth of the CWSC d. Temperature of the water in the CWSC 10. On an indirect cold water system, the cold feed outlet from the CWSC to the domestic hot water cylinder should be? a. Level with the cold distribution outlet b. Lower than the cold distribution outlet c. Located at the base of the cistern d. Higher than the cold distribution outlet 11. On a cold water system conforming to the Water Regulations, which of the following should be turned off to isolate the WC float valve? a. Supply stop valve b. Appliance service valve c. Water supplier s stop valve d. Distributing service valve 12. In areas where the water supply is poor during periods of peak demand, what type of system would usually be specified for a domestic dwelling? a. Direct Cold Water System b. Boosted Cold Water System c. Indirect Cold Water System d. Secondary Cold Water System Muscroft Plumbing: Curriculum Support Pack: classroom handouts

39 13. An overflow pipe as well as a warning pipe is required on cisterns with a capacity in excess of: a. 115 litres b. 230 litres c litres d litres 14. On a cold water storage cistern with a capacity of 115 litres, what is the required distance between the water level and the outlet of the warning pipe? a. 25mm b. 35mm c. 40mm d. 45mm 15. In a direct system of cold water supply, the purpose of the cold feed pipe is to: a. Replace the water to the hot water storage cylinder as it is drawn off b. Provide a means of filling the cold water storage cistern from the mains c. Supply the water to the various cold water outlets within the system d. Prevent the cistern from overflowing should the float operated valve fail 16. On a new cold water system conforming to the Water Regulations, which of the following should be turned off to isolate the float valve to the cold water storage cistern? a. Appliance service valve b. Supply pipe service valve c. Water supplier s stop valve d. Distributing service valve 17. The Water Regulations require that the water temperature in CWSCs and cold water pipework should not exceed: a. 20ºC b. 21ºC c. 23ºC d. 25ºC Muscroft Plumbing: Curriculum Support Pack: classroom handouts

40 18. Where a CWSC is located in the roof space of a dwelling and the space beneath it contains thermal installation, what action should a plumber take? a. Increase the depth of insulation by 50mm b. Increase the depth of insulation by 100mm c. Decrease the depth of insulation by 50mm d. Remove the insulation from beneath the CWSC 19. The minimum unobstructed space for a cistern of a 1000L or less is: a. 250mm b. 350mm c. 400mm d. 450mm 20. The purpose of pipework insulation material is to: a. Prevent the water in the pipe from freezing in cold weather b. Protect the pipework and fittings from accidental damage c. Retain the heat energy in the pipe to reduce the risk of freezing d. Insulate the pipework should it come into contact with a live cable Muscroft Plumbing: Curriculum Support Pack: classroom handouts

41 Answers to activities and test yourself questions Answers to Activities Activity 5.1 The objectives of the regulations are to: Prevent the waste of water i.e. (faulty appliances, poor maintenance, leaking fitting e.g. dripping tap) Prevent misuse of a water supply i.e.(the use of energy in the mains supply to provide motive power, or for the generation of electricity) Prevent undue consumption of water i.e. (fittings and appliances that use more water for the purpose they were designed) Prevent Erroneous measurement i.e.(tampering and interference with the measurement of water passing through the meter e.g. fiddling the meter) Activity 5.2 The physical forms of water are: Solid -as ice. Liquid - as water. Gas - as steam or vapour. At atmospheric pressure, and at a temperature of between 0ºC to 100ºC water will be found as a liquid. At a temperature of 0ºC or below, water changes to ice, expanding immediately in volume by 10% (hence the reason water pipes burst when frozen) When subject to a temperature above 100ºC, water will change to steam, expanding in volume by approximately 1600 times. Muscroft Plumbing: Curriculum Support Pack: classroom handouts

42 Activity 5.3 Direct systems offer the following advantages: Cheaper installation costs, due to less pipework being required. Drinking water is available from all draw off points. Water storage will only be required to feed the hot water storage vessel, so the storage cistern will be smaller in size. The minimum requirement being 115 litres. The disadvantages are: The higher water pressure may make the system suffer transmission noise e.g. water hammer. No reserve of water if the mains or service supply is shut off for a period of time. Precautions must be taken so to prevent back siphonage occurring (water flowing back) or fowled water from appliances, contaminating the mains supply. Remember this is a requirement of the Water Regulations. (you may have missed this one) The indirect system offers the following advantages: Lower delivery pressure reduces the risk of system noise. Lower demand on the water main at peak periods. There s a reserve supply of water should the mains supply be turned off, for a period of time. The wear and tear element on taps and valves is reduced, due to the lower delivery pressure. The disadvantages are: Higher installation cost for larger storage cistern and additional fittings and pipework. Larger diameter of pipework required, to appliances. Additional structural support will be required for the increased weight of a larger storage cistern. The storage cistern will require an increased space or area (minimum capacity is 230litres). Increased risk of damage from frost. Muscroft Plumbing: Curriculum Support Pack: classroom handouts

43 Activity 5.4 What do you think is the main advantage of fitting servicing valves? The main advantage is that it enables maintenance work to be carried out to the cistern without turning off the whole water supply. Activity 5.5 The illustration above shows an external stand pipe installation. Can you identify the key design features? Write down your findings and check them out at the end of the unit. The installation is fitted with a drain tap; which allows the pipework to be drained once the stop tap has been turned off. The minimum depth of 750 mm below ground still applies to installations of this type. The double check valve fitted to protect against backflow contamination to the water supply meets the requirements of Schedule2: paragraph 15 (1) of the Water Regulations. Muscroft Plumbing: Curriculum Support Pack: classroom handouts

44 Test yourself answers 5.1 Test yourself answers 1. Water Supply (Water Fittings) Regulations One from; Prevent contamination of the water supply Prevent the waste of water Prevent misuse of the water supply Prevent undue consumption of water. Erroneous measurement 3. 10% 4. Hard water 5. Two from: Wells Artesian wells Springs 6. Water evaporates from rivers, lakes, the sea and the ground which in turn forms clouds. Clouds contain water vapour which, when the climatic conditions are right, condense and fall as rain. When rain falls to the ground, some runs into streams, rivers, and lakes, the remainder soaks into the ground, where it collects temporarily and eventually evaporates. 5.2 Test yourself answers mm min and 1350mm max 2. Base exchange water softeners Electrolytic scale inhibitors or Electromagnetic conditioners 3. Isolate the water supply Permit maintenance and servicing to be carried out on systems 4. Two examples from: - Supply to hose taps - Supply to standpipes - Pipe connection to cisterns using part 1 float valves - Supply to shower fitting Muscroft Plumbing: Curriculum Support Pack: classroom handouts

45 5. The paragraph below describes the difference between a direct and indirect cold water system, fill in the missing words. All the pipes to the draw off points (kitchen sink, bath, wash hand basin, wc, etc) in a direct system are taken directly from the rising main and operate under mains pressure. With the indirect system, one outlet usually the kitchen sink is fed directly from the rising main, before it continues to supply the CWSC. The remaining draw off points are fed from this source. 6. State two main forms of frost protection used on cold water installations. Pipe, components and cistern insulation Trace heating Muscroft Plumbing: Curriculum Support Pack: classroom handouts

46 Cold water storage cisterns Cisterns storing water for domestic purposes should be: Fitted with a supply float operated valve to maintain the correct water level in the cistern. The float valve must be fitted as high as possible within the cistern. It must comply with the requirements of BS1212 part 2 or 3, in order to maintain an air gap and prevent the possibility of back siphonage into the incoming supply. This meets the requirements of the Water Regulations Schedule 2 paragraph 16 (1). Float valves complying with BS 1212 Part 1 valves may be used, providing it has an adjustable float lever connection. Fitted with service valves on inlet and outlet pipes for maintenance or servicing purposes and for shutting off the flow of water in a pipe to a water fitting. This meets the requirements of the Water Regulations Schedule 2 paragraph 16 (3). Covered with a securely fixed lid, that is not air tight, but excludes light or insects. The lid shall incorporate a screened air inlet, and where the vent pipe from the hot water cylinder passes through it, and be appropriately sleeved. Fitted with a screened overflow/ warning pipe to warn of overflow discharge. The overflow pipe must have a minimum internal diameter of 19mm, and in all instances be greater in size than the incoming inlet pipe. Installed so as to minimise the risk of contamination of the stored water. The pipework connections must also be positioned to allow the water to circulate freely preventing the possibility of stagnant water. Insulated to protect against frost and freezing, and to prevent heat gain of the stored water. Keeping the water temperature below 20ºC will restrict the possibility of microbiological growth bacteria such as Legionella. Fully supported on the whole of its base area. This will prevent undue stress on pipe connections and distortion of the cistern when filled with water, which could result in leaks. Installed in an accessible position, to allow ease of maintenance and for cleaning purposes. There must be a minimum clearance height of 350mm above the top of the cistern. In order to reduce the risk of water-borne diseases such as Legionella in water storage systems, it s recommended that the outlet connection be positioned as near as possible to the bottom of the cistern. This allows any small particles that may be present to pass through the system, preventing an unhealthy build-up of sediment at the base of the cistern. Muscroft Plumbing: Curriculum Support Pack: classroom handouts

47 Use of check valves Single Check Valves - Connected prior to water softener - Unvented heating systems - Supply to wet sprinkler system - Downstream of meters and pressure reducing valves (no specific regulation but essential for correct operation of equipment) Double Check Valves - Supply to hose taps - Supply to standpipes - Pipe connection to cisterns using part 1 float valves - Supply to shower fitting Shower Check Valves - Supply to shower spray head where shower hose pipe is unconstrained eg. air gap requirement cannot be guaranteed. Muscroft Plumbing: Curriculum Support Pack: classroom handouts

48 Sources of Information We have included references to information sources at the relevant points in the text; here are some additional contacts that may be helpful. Pegler limited St Catherine s Avenue Doncaster South Yorkshire DN4 8DF Tel: Website: Yorkshire Fittings Head Office PO Box 66 Leeds LS10 1NA Tel: info@yorkshirefittings.co.uk Website: Muscroft Plumbing: Curriculum Support Pack: classroom handouts

49 Lesson Plan Tutor: Programme Area: Plumbing Room Number: Date: Course code & title: 6129 City & Guilds basic certificate in plumbing Session Title: 8 Practical training and assessment Overall aims of session Introduction to maintenance of valves and fittings. Demonstration of re-washering taps, float valves and repairing siphons. Session objectives At the end of the session learners will be able to: Identify types of tap. Re-washer a float valve. Continue training tasks. Assessment strategies How will you & the learners know they have (fully/partly/not) achieved the objectives? Observation of learning activities. Peer assessment. Assessment with verbal and written feedback. Health & safety Have you checked the room & resources before the lesson? Note any issues that need to be passed on to the College H&S officer or Campus Services Yes No Equality & Diversity How are you ensuring your session promotes E&D/is inclusive? Students will work from practical training pack and formal assessment portfolio. All students will be given equal opportunity to complete the set exercises. Differentiation (include roles of any Learning Support Assistants) Students will be allowed to work at their own speeds. Tutors are to ensure that all students are supported and encouraged to progress. Muscroft Plumbing Curriculum Support Pack: Lesson Plans

50 Timing (minutes) Activity Resources (including ILT) Interaction Method of assessment (I, F or S *) 30 Tutor presentation (Identifying and repairing common faults on plumbing systems) 75 Training tasks as set out within the training portfolio Taps, float valves and syphons Training pack Demonstration Individual practical training Break 30 Tutor presentation (Repacking glands, other symptoms and faults that may occur) 75 Training tasks as set out within the training portfolio Various fittings and scenarios Training pack Demonstration Individual practical training Evaluation of session What went well? / How have I gained this feedback? / How will you share this with colleagues? What would you change for next time? * I = Initial Assessment, F = Formative Assessment, S = Summative Assessment Muscroft Plumbing Curriculum Support Pack: Lesson Plans

Water Supply (Water Fittings) Regulations 1999

Water Supply (Water Fittings) Regulations 1999 Water Supply (Water Fittings) Regulations 1999 Information for anyone installing, modifying or maintaining domestic plumbing systems Guidance notes for domestic plumbing system Independent Water Networks

More information

Installing, modifying and maintaining domestic plumbing systems. Water Supply (Water Fittings) Regulations 1999

Installing, modifying and maintaining domestic plumbing systems. Water Supply (Water Fittings) Regulations 1999 Installing, modifying and maintaining domestic plumbing systems Water Supply (Water Fittings) Regulations 1999 Page 2 On 1 July 1999 Southern Water and all other water suppliers in England and Wales began

More information

REGISTRATION EXAMINATION, JUNE 2015 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

REGISTRATION EXAMINATION, JUNE 2015 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 99 REGISTRATION EXAMINATION, JUNE 05 LICENSED PLUMBER INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed

More information

Water Regulations Tutorial # 6 Conservation

Water Regulations Tutorial # 6 Conservation Arrow Valves Ltd Water Regulations Tutorial #6 Conservation Arrow Valves Tel 01442 823 123 Fax 01442 823 234 www.arrowvalves.co.uk Water Regulations Tutorial # 6 Conservation Updated 18/07/16 The new Water

More information

-SQA- SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR

-SQA- SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR -SQA- SCOTTISH QUALIFICATIONS AUTHORITY Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR -Module Number- 4250701 -Session-1991-92 -Superclass- TH -Title- PLUMBING:

More information

ADVANCE ELECTRIC THERMAL STORE

ADVANCE ELECTRIC THERMAL STORE ISSUE 13 1118 INSTALLATION AND USER GUIDE ADVANCE ELECTRIC THERMAL STORE ADVANCE APPLIANCES LTD HOUSEHOLDER PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE. 2 INTRODUCTION Advance thermal

More information

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9 Contents Product Description 2 Approvals 2 Warranty 2 Warnings 2 Technical Specification 3 Installation 4 Location 4 Plumbing Connection 4 Electrical connection 5 Commissioning 6 Operation 6 Routine Preventative

More information

Komo Thermostatic Bar Shower. Excluding Shower Kit

Komo Thermostatic Bar Shower. Excluding Shower Kit Komo Thermostatic Bar Shower. Excluding Shower Kit Bar Shower Size Pattern No. Pack 1 Qty Pack 2 Qty Code Barcode Price ( ) ex VAT NA Bar Shower CP 1 0 4S4001 5013866052750 180.25 Bar Shower Code 4S4001

More information

ADVANCE ECB ELECTRIC COMBINATION BOILER

ADVANCE ECB ELECTRIC COMBINATION BOILER ISSUE ISSUE 45 0115 0317 INSTALLATION AND USER GUIDE ADVANCE ECB ELECTRIC COMBINATION BOILER ADVANCE APPLIANCES LTD HOUSEHOLDER - PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE 1 SCHEMATIC

More information

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower e x p e r i e n c e d e s I g n i n n o v a t i o n You re Guide to the Installation, Care and maintenance of Francis Pegler Memento Single Sequential Exposed Thermostatic Shower For further information,

More information

HOME INSPECTION CHECKLIST

HOME INSPECTION CHECKLIST HOME INSPECTION CHECKLIST Date: Page 1 of 9 Client Name: Address: Tel No: Surname: Email: A WATER METER 1 Is the water meter visible YES NO 2 Water meter registers when water is drawn YES NO 3 Water meter

More information

Pear Kitchen Sink Tap

Pear Kitchen Sink Tap Pear Kitchen Sink Tap Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s leading

More information

REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER ANSWER SCHEDULE

REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER ANSWER SCHEDULE No. 9192 REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2017. All rights reserved. No part of this publication may be reproduced by

More information

Installation Instructions Flute Tap Range

Installation Instructions Flute Tap Range Installation Instructions Flute Tap Range Models covered: FLT BAS C, FLT 1HBF C, FLT 2HBSM C, FLT TBAS C Please keep this booklet for future reference. Installer, when you have read these instructions

More information

Risk Assessment and Control Measures for Household Hot Water Systems

Risk Assessment and Control Measures for Household Hot Water Systems Risk Assessment and Control Measures for Household Hot Water Systems Introduction and Scope The impending changes to the Part G Building regulations have focussed attention on some of the potential hazards

More information

Target Monobloc Kitchen Mixer Chrome

Target Monobloc Kitchen Mixer Chrome Target Monobloc Kitchen Mixer Chrome Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan,

More information

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15 CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15 COMPACT PLUS 10 and 15 Litre Unvented Under and Over Sink Water Heater INSTALLATION AND USER GUIDE 1 DIMENSIONS 10L - 250mm 15L - 310mm 100mm 80mm 410mm

More information

DOMESTIC WATER RECORDS

DOMESTIC WATER RECORDS DOMESTIC WATER RECORDS LEGIONELLA LOG BOOK RESPONSIBLE SITE STAFF PARSONS HALL INDUSTRIAL ESTATE HIGH STREET IRCHESTER NORTHANTS NN29 7AB TEL: 01933 410066 FAX: 01933 410077 www.beaconwater.co.uk DOMESTIC

More information

Beeline Monobloc Kitchen Mixer Tap

Beeline Monobloc Kitchen Mixer Tap Beeline Monobloc Kitchen Mixer Tap Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the

More information

Trade of Plumbing. Module 2: Domestic Hot and Cold Water Service Unit 10: Hot Water Supply Phase 2

Trade of Plumbing. Module 2: Domestic Hot and Cold Water Service Unit 10: Hot Water Supply Phase 2 Trade of Plumbing Module 2: Domestic Hot and Cold Water Service Unit 10: Hot Water Supply Phase 2 Table of Contents List of Figures... 4 List of Tables... 5 Document Release History... 6 Module 2 Domestic

More information

Understand and apply domestic hot water system installation, commissioning, service and maintenance techniques

Understand and apply domestic hot water system installation, commissioning, service and maintenance techniques Level: 3 Credit value: 9 URN: K/502/9155 Unit aim This combination unit provides learning in the design, installation, maintenance, and commissioning of a complex range of hot water system/component types

More information

REGISTRATION EXAMINATION, NOVEMBER 2014 LICENSED PLUMBER ANSWER SCHEDULE

REGISTRATION EXAMINATION, NOVEMBER 2014 LICENSED PLUMBER ANSWER SCHEDULE No. 9192 REGISTRATION EXAMINATION, NOVEMBER 2014 LICENSED PLUMBER ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2014. All rights reserved. No part of this publication may be reproduced by

More information

PULSACOIL 2000 USER GUIDE. TEL:

PULSACOIL 2000 USER GUIDE. TEL: PULSACOIL 2000 USER GUIDE Gas Council Approved Reference Numbers PulsaCoil 145 97-317-32 PulsaCoil 185 97-317-33 PulsaCoil 215 97-317-34 PulsaCoil 235 97-317-35 A mains pressure hot water supply system

More information

Thermostatic Bath Shower Mixer. Without shower kit.

Thermostatic Bath Shower Mixer. Without shower kit. Thermostatic Bath Shower Mixer. Without shower kit. 555QT Size Pattern No. Pack 1 Qty Pack 2 Qty Code Barcode Price ( ) ex 555QT Code A B C D E F Pegler Yorkshire reserve the right to change specifications

More information

CRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING ANSWER SCHEDULE

CRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING ANSWER SCHEDULE No. 9195 CRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2007. All rights reserved. No part of this publication may be reproduced by any means without

More information

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual POWERFLOW Series Unvented Electric Storage Water Heaters Installation & Operating Instructions Manual These Instructions must be left with the user after installation. Version 3.0 June 2009 Hyco POWERFLOW

More information

Artisan Thermostatic Bath Filler

Artisan Thermostatic Bath Filler Artisan Thermostatic Bath Filler Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts General Information Thank you for choosing Bristan,

More information

Pipe Sizing Table. Hydraulic Load Served (fixture units)

Pipe Sizing Table. Hydraulic Load Served (fixture units) MODULE 1 INTRODUCTION Notes: A Pipe Type Horizontal branch Pipe Sizing Table Hydraulic Load Served (fixture units) Size (in.) Code Reference 2 + 1.5 = 3.5 2 7.4.9.1.(1) B Soil stack 13.5 + 13.5 = 27 3

More information

AIR ADMITTANCE VALVES FOR DOMESTIC PROPERTIES Guidance Notes

AIR ADMITTANCE VALVES FOR DOMESTIC PROPERTIES Guidance Notes AIR ADMITTANCE VALVES FOR DOMESTIC PROPERTIES Guidance Notes 02 AIR ADMITTANCE VALVES FOR DOMESTIC PROPERTIES Introduction For any system which drains waste water from a property to function correctly,

More information

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS 6 th June 2006 Page 1 WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS Please read and follow all these instructions carefully before proceeding

More information

Understand and apply domestic central heating system installation and maintenance techniques

Understand and apply domestic central heating system installation and maintenance techniques Level: 2 Credit value: 10 URN: Y/602/2888 Unit aim This combination unit provides basic learning in the installation, maintenance, decommissioning and soundness testing of a basic range of wet central

More information

PULSACOIL A CLASS USER GUIDE. TEL:

PULSACOIL A CLASS USER GUIDE. TEL: PULSACOIL A CLASS USER GUIDE Model Numbers PulsaCoil 145 PulsaCoil 185 PulsaCoil 215 PulsaCoil 235 A mains pressure hot water supply system incorporating an off peak electric thermal store TEL: 0800 14

More information

Technical Checklist - Plumbing and Heating Fittings - UK Sizes

Technical Checklist - Plumbing and Heating Fittings - UK Sizes Technical Checklist - Plumbing and Heating Fittings - UK Sizes July 2008 NOTE: This checklist refers exclusively to fittings and accessories from our range of push-fit products for Plumbing and Heating

More information

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Thank you

More information

Assessment Schedule - TS8

Assessment Schedule - TS8 The Assessor shall determine the business s commitment and support to good and safe working practices; also that it has a positive culture in all aspects of its work. In particular, the assessor shall

More information

Description of the property and water systems:

Description of the property and water systems: Site Address: 165 Netherstowe Lane Lichfield Staffordshire WS13 6BA Assessor's Information: Alan Greaves 01543 416476 07866362749 ala@hsg274.co.uk Description of the property and water systems: The property

More information

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide : GUARANTEE AND CONTACT DETAILS REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER Installation and User Guide APPLIED ENERGY PRODUCTS LIMITED MORLEY WAY, PETERBOROUGH PE2 JJ TEL: +44 (0) 844 372

More information

Section 7 F/602/2884 Understand and apply domestic hot water system installation and maintenance techniques

Section 7 F/602/2884 Understand and apply domestic hot water system installation and maintenance techniques 1 Section 7 F/602/2884 Understand and apply domestic hot water system installation and maintenance techniques 2 F/602/2884 - Understand and apply domestic hot water system installation and maintenance

More information

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C, Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C, EXD SHCVO C, SAI SHCVO C, GLR SHCVO C, BRG SHCVO C, HOU SHCVO

More information

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500 Unvented Calorifier Range. Operating and Maintenance Manual. For Models 125 300 & 500 Telephone 08456 448802 Fax 08456 448803 Emial info@mhgheating.co.uk Web www.mhgheating.co.uk TABLE OF CONTENTS. Section

More information

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION SOLARCYL IM/SC INSTALLATION MANUAL This manual gives detailed advice for installation and should be read carefully prior to fitting any unvented

More information

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier OM001 Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier These operating and maintenance instructions are for standard semi-storage calorifiers (vessels fitted with

More information

Installation & Technical Guide. Domestic & Commercial.

Installation & Technical Guide. Domestic & Commercial. Installation & Technical Guide Domestic & Commercial www.challisbooster.com www.challisboosterplus.com Installation and Technical Guide Domestic and Commercial Challis Water Controls Europower House, Lower

More information

Part 8. Services and internal finishing. 8.1 Internal services. 8.2 Wall and ceiling finishes. 8.3 Floor finishes. 8.4 Finishings and fitments

Part 8. Services and internal finishing. 8.1 Internal services. 8.2 Wall and ceiling finishes. 8.3 Floor finishes. 8.4 Finishings and fitments Part 8 Services and internal finishing 8.2 Wall and ceiling finishes 8.3 Floor finishes 8.4 Finishings and fitments 8.5 Painting and decorating PAGE 375 Part 8 Services and internal finishing Chapter CONTENTS

More information

Designs of domestic bathrooms, guidance and advice from

Designs of domestic bathrooms, guidance and advice from Designs of domestic bathrooms, guidance and advice from www.anglianwater.co.uk Domestic bathroom designs Contents Introduction... 3 What seems to be the problem?... 3 Understanding the problem... 3 Alternative

More information

Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE

Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE WATERHEATER MANUFACTURERS ASSOCIATION Tel 01952 257963 Fax 01952 253452 Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE www.telford-group.com STAINLESS PRODUCTS Tornado &

More information

INSTANTANEOUS ELECTRIC SHOWER

INSTANTANEOUS ELECTRIC SHOWER GUARANTEE / SERVICE POLICY INSTANTANEOUS ELECTRIC SHOWER GUARANTEE Designa guarantee this DS3000 product for a period of two years, from date of purchase, against mechanical and electrical defects arising

More information

TREVI BLEND SINGLE LEVER SHOWER VALVES. INSTALLER After installation pass to user for future reference

TREVI BLEND SINGLE LEVER SHOWER VALVES. INSTALLER After installation pass to user for future reference 11 A4000, A4100 & A4110 TREVI BLEND PARTS LIST Ref. Description 1 Lever handle complete 1a/1b Nut and washer 2 Handle cover cap 3 Shield 4 Cover plate fixing screw 5.1 Cover plate for built in version

More information

Total Hot Water Solutions

Total Hot Water Solutions H ot Wa te r Syste m s Copper Hot Water Products Total Hot Water Solutions www.copperform.co.uk selection guide Copperform Ltd is part of the Kingspan Hot Water Systems Group of companies, and manufactures

More information

NENE. Installation and Operating Instructions. Thermostatic bar mixer shower PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

NENE. Installation and Operating Instructions. Thermostatic bar mixer shower PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER NENE Thermostatic bar mixer shower Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 2180430B October 2005 CONTENTS Page Introduction 1 Safety

More information

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space. DPS Hi-Flow Mains Pressure Hot Water from an existing vented copper cylinder... Converts an existing hot water cylinder to provide potable mains pressure hot water at high flow rates to all existing outlets.

More information

Unvented Electric Water Heater 10/15 litre Undersink

Unvented Electric Water Heater 10/15 litre Undersink Unvented Electric Water Heater 10/15 litre Undersink Fitting Instructions and User Guide 1 CONTENTS SECTION PAGE 1.0 INTRODUCTION 2 2.0 TECHNICAL SPECIFICATION 3 3.0 INSTALLATION 4 4.0 COMMISSIONING 9

More information

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER Installation and User Guide IMPORTANT: This booklet should be left with the user after installation and demonstration. It should be kept in a safe

More information

METRO BASIN MONO MIXER CHR

METRO BASIN MONO MIXER CHR METRO BASIN MONO MIXER CHR 20004010020 This product should only be fitted by a qualified plumber to NVQ (National Vocational Qualification) or SNVQ (Scottish National Vocational Qualification) Level 3.

More information

REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 99 REGISTRATION EXAMINATION, NOVEMBER 07 TRADESMAN PLUMBER INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed

More information

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses INSPIRED H I G H H O T EF F ICIENCY E F F I C I E N C Y W A T E R S Y S T E M S E XT REME HIGH EFFICIENCY HO T W AT ER SY ST EMS w i th I N JECT I O N DYN A M I C S T ECHN I CAL DO CUME N TA T I O N I

More information

PULSACOIL 2000 ELECTRIC THERMAL STORE USER INSTRUCTIONS

PULSACOIL 2000 ELECTRIC THERMAL STORE USER INSTRUCTIONS PULSACOIL 2000 ELECTRIC THERMAL STORE USER INSTRUCTIONS benchmark TM The code of practice for the installation, commissioning & servicing of central heating systems In the interest of continuously improving

More information

SEALED THERMAL STORE

SEALED THERMAL STORE ISSUE 3 0717 INSTALLATION AND USER GUIDE ENERGYMANAGER SEALED THERMAL STORE ADVANCE APPLIANCES LTD PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE. SCHEMATIC DIAGRAM OF ENERYMANAGER THERMAL

More information

UB110DNC/L/U/B BASIN MONOBLOC WITH NO POP-UP WASTE BASIN MONOBLOC TALL WITH NO POP-UP WASTE UB112DNC/L/U/B INSTALLATION INSTRUCTIONS

UB110DNC/L/U/B BASIN MONOBLOC WITH NO POP-UP WASTE BASIN MONOBLOC TALL WITH NO POP-UP WASTE UB112DNC/L/U/B INSTALLATION INSTRUCTIONS BASIN MONOBLOC WITH NO POP-UP WASTE BASIN MONOBLOC TALL WITH NO POP-UP WASTE UB110DNC/L/U/B UB112DNC/L/U/B INSTRUCTIONS INTRODUCTION DIMENSIONS Please read these instructions carefully and keep in a safe

More information

Hotflo. Unvented point of use hot water

Hotflo. Unvented point of use hot water Unvented point of use hot water We developed the range for people who need a hot water supply for two to three basins or sinks. Flexible siting is a key design feature that we insisted upon because it

More information

Mira Atom ERD Thermostatic Bar Valve

Mira Atom ERD Thermostatic Bar Valve Mira Atom ERD Thermostatic Bar Valve These instructions must be left with the user Installation and User Guide 1 1340912-W2-A 1340912-W2-A 2 Introduction Thank you for purchasing a quality Mira product.

More information

METRO BATH FILLER MOUNTED CHR

METRO BATH FILLER MOUNTED CHR METRO BATH FILLER MOUNTED CHR 20004010050 For any further information please contact Bathstore on: 0845 873 8843 INSTRUCTIONS Or visit our web-site at www.bathstore.com P5-6P8P7-B-BS-E A/4 The manufacturer

More information

Multi-Elec COMPACTE BOILER

Multi-Elec COMPACTE BOILER Multi-Elec COMPACTE BOILER TECHNICAL MANUAL 03/2013 CODE: 560956 CE Directive 2006/95/CEE British Standard EN 60335-1 (C 73800) FOR TECHNICAL HELP/ADVICE Call 0161 621 5960 or email info@atlanticboilers.com

More information

Hamad bin Isa Al Khalifa King of The Kingdom of Bahrain

Hamad bin Isa Al Khalifa King of The Kingdom of Bahrain His Majesty King Hamad bin Isa Al Khalifa King of The Kingdom of Bahrain His Royal Highness Prince Khalifa bin Salman Al Khalifa The Prime Minister His Royal Highness Prince Salman bin Hamad Al Khalifa

More information

Dene Bath Shower Mixer

Dene Bath Shower Mixer Dene Bath Shower Mixer Installation and operating instructions The showerhead and hose supplied with this product are an integral part of the safety of your shower. Failure to use genuine Triton parts

More information

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION 0 RD 0 RI 0000-06 IM/ IM/a INSTALLATION MANUAL This manual gives detailed advice for installation and should be read carefully prior to fitting

More information

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER Thank you for choosing a quality Redring product manufactured by

More information

WATER DOMESTIC PROPERTIES REGULATIONS FOR. Information guide for your home

WATER DOMESTIC PROPERTIES REGULATIONS FOR. Information guide for your home WATER REGULATIONS FOR DOMESTIC PROPERTIES Information guide for your home DOES YOUR HOME COMPLY WITH WATER FITTINGS REGULATIONS? The Water Supply (Water Fittings) Regulations were introduced in 1999 by

More information

Installation and Servicing Instructions

Installation and Servicing Instructions Installation and Servicing Instructions Zenex GasSaver GS-1 Passive Flue Gas Heat Recovery Device (PFGHRD) Recognised by the Government s Standard Assessment Procedure (SAP) IMPORTANT: Read these instructions

More information

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring Page 1 of 8 IMAGINATION SOLAR LTD Installation Guide B1 Planning the Plumbing and Wiring Unit 4 Montpelier Central, Station Road Bristol BS6 5EE t: 0117 942 6668 f: 0117 942 8998 e: enquiries@imaginationsolar.com

More information

Sema thermostatic bar mixer Installation and operating instructions

Sema thermostatic bar mixer Installation and operating instructions Sema thermostatic bar mixer Installation and operating instructions Installers please note these instructions are to be left with the user 2180579A September 2006 CONTENTS Page Introduction 1 Safety warnings

More information

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve Models covered: SHP01. Please keep this booklet for future reference. Installer, when you have read these instructions

More information

Quartz. Thermo. Concealed shower valve with adjustable head. Quartz Thermo installation guide page 1

Quartz. Thermo. Concealed shower valve with adjustable head. Quartz Thermo installation guide page 1 Quartz Thermo Concealed shower valve with adjustable head Quartz Thermo installation guide page 1 Shower systems Components Quartz Thermo built-in shower valve with adjustable head QZ3111 Quartz Thermo

More information

Bath Shower Mixer

Bath Shower Mixer 86004490 Bath Shower Mixer Installation and operating instructions The showerhead and hose supplied with this product are a safety critical part of your shower. Failure to use genuine Triton parts may

More information

COMPRESSION PLUMBING SOLUTIONS CONNECT WITH CONFIDENCE

COMPRESSION PLUMBING SOLUTIONS CONNECT WITH CONFIDENCE COMPRESSION PLUMBING SOLUTIONS CONNECT WITH CONFIDENCE CONNECT WITH CONFIDENCE With a wealth of expertise and the broadest range of solutions and systems on the market, Pegler Yorkshire s Connect products

More information

Thermostatic bar mixer valve with adjustable head Installation guide

Thermostatic bar mixer valve with adjustable head Installation guide Bar valve Thermostatic bar mixer valve with adjustable head Installation guide Index Introduction p.3 - Safety information p.3 - Product specification p.3 Connection to supplies p.3 - Flushing p.4 - Filters

More information

Owners Manual for the Rainmaster Water Recycling System

Owners Manual for the Rainmaster Water Recycling System Owners Manual for the Rainmaster Water Recycling System 22874 Manual.indd 1 4/8/05 8:45:05 AM Rain Master Water Recycling System Welcome! Thank you for purchasing a Rainmaster Water Recycling System. Your

More information

CENTRA-COIL QUALITY HOT WATER SERVICE

CENTRA-COIL QUALITY HOT WATER SERVICE CENTRA-COIL QUALITY HOT WATER SERVICE INSTALLATION AND OWNERS MANUAL WARNING This water heater should be installed in accordance with the requirements of AS 3500.4. The owner should also be aware of any

More information

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration in tap Boiling water to in tap sink Drain Valve (as high as possible) REDITAP CONNECTION SUMMARY Amp mains supply cold mains water into in tap optional filter cold water in hot water BOILING UNIT Installation

More information

Assessment Schedule - TS.6

Assessment Schedule - TS.6 The Assessor shall determine the business s commitment and support to good and safe working practices; also that it has a positive culture in all aspects of its work. In particular, the assessor shall

More information

Basin Tap. Time delay maximum 2 seconds

Basin Tap. Time delay maximum 2 seconds Basin Tap. Time delay maximum 2 seconds 876 Size Pattern No. Pack 1 Qty Pack 2 Qty Code Barcode Price ( ) ex 1/2 876 Hot 1 5 314007 5013866005022 142.41 1/2 876 Cold 1 5 314017 5013866005039 142.41 876

More information

USING YOUR PRESSURE SEWER SYSTEM

USING YOUR PRESSURE SEWER SYSTEM USING YOUR PRESSURE SEWER SYSTEM A homeowner s manual About this manual This manual will assist you with the operation and maintenance of the pressure sewer system installed on your property. We strongly

More information

Powerflow Unvented water heater

Powerflow Unvented water heater Product Instruction Manual Powerflow Unvented water heater 30, 50 and 90 litres v15.6/5 Thank you for purchasing a Powerflow series unvented electric water heater. The Powerflow is suitable for hand washing

More information

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater HEATRAE SADIA The quality name in water heating Installation and User Instructions for the UTC Undersink Vented Water Heater UTC 15 Please read and understand these instructions before starting work. Please

More information

CUBEflow Thermal Store Tank

CUBEflow Thermal Store Tank CUBEflow Thermal Store Tank Installation & Technical Manual Tel: (01592) 611123 www.mcdonaldwaterstorage.com September 2018 CUBEflow Thermal Store Tank, Installation & Technical Manual Manual must be completed

More information

Approved. Document. Sanitation, hot water safety and water efficiency. The Building Regulations 2010

Approved. Document. Sanitation, hot water safety and water efficiency. The Building Regulations 2010 The Building Regulations 2010 Approved G1 Cold water supply G2 Water efficiency G3 Hot water supply and systems G4 Sanitary conveniences and washing facilities G5 Bathrooms G6 Kitchens and food preparation

More information

X62 Tap Range. Please keep these instructions for future reference

X62 Tap Range. Please keep these instructions for future reference X62 Tap Range This instruction booklet covers: X625205CP, X625215CP, X625255CP, X625265CP, X625122CP, X625126CP, X625135CP Please keep these instructions for future reference 02 For latest prices and delivery

More information

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008 Varipoint cover qxd:varipoint cover qxd 22/8/08 11:14 Page 1 Installation, Maintenance and User Instructions ZIP Varipoint III Models VP303, VP503 VP803, VP953 direct unvented water heaters Issued August

More information

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER ENERSTORE Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER Newark Copper Cylinder Co Ltd Brunel Drive Newark Notts. NG24 2EG Tel: 01636 678437 Fax: 01636 678964 Internet: www.newarkcoppercylinder.co.uk

More information

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION Ecoline Geo RI HP INSTALLATION MANUAL The Ecoline GEO is an indirect unvented cylinder designed and approved for use with a heat pump. The

More information

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION CHECK LIST Make

More information

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE:

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE: TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE: 560955 CE Directive 2006/95/CEE British Standard EN 60335-1 (C 73800) 1 CONTENTS Page 1) INTRODUCTION 1.1) Description 3 1.2) Dimensions & connections

More information

SUN EQUINOX HEATING SYSTEMS

SUN EQUINOX HEATING SYSTEMS SUN EQUINOX HEATING SYSTEMS HIGH-EFFICIENCY HOT WATER SOLUTIONS INSTALLATION & OPERATION MANUAL Production Number: Customer Contact Information Other Resources 260-65-5605 http://www.solarusagenow.com

More information

In-line thermostatic mixing valves

In-line thermostatic mixing valves In-line thermostatic Pegler Yorkshire Unrivalled quality, innovation, customer service and long-term value for money As part of the global Aalberts Industries NV Group, Pegler Yorkshire is one of Britain

More information

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve with Integral Diverter

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve with Integral Diverter Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve with Integral Diverter Models covered: CAS SHCDIV C, COB SHCDIV C, ORB SHCDIV C, EXD SHCDIV C, SAI SHCDIV C, GLR

More information

CalMag Heating Pack Installation Instructions

CalMag Heating Pack Installation Instructions Calming troubled waters CalMag Heating Pack Installation Instructions Heating Filter Corrosion Inhibitor Scale Inhibitor (if applicable) Cleanser Acidic Neutraliser CalMag HF2 Filter Installation Instructions

More information

Parenzo Range. Basin Mixer, Bath Filler & Bath Shower Mixer. Assembly instructions

Parenzo Range. Basin Mixer, Bath Filler & Bath Shower Mixer. Assembly instructions Parenzo Range Basin Mixer, Bath Filler & Bath Shower Mixer Assembly instructions We have designed these products with your enjoyment in mind. To ensure that they work to their full potential, they need

More information

INSTALLATION & TECHNICAL MANUAL

INSTALLATION & TECHNICAL MANUAL The COMET Range of Boilers the ultimate solution for central heating INSTALLATION & TECHNICAL MANUAL If you require any further assistance: Telephone: 01698 820533 Fax: 01698 825697 E-mail: info@electric-heatingcompany.co.uk

More information

Pisa Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Pisa Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts Pisa Tap Range Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Thank you for choosing Bristan, the UK s leading taps and showers

More information

DOMESTIC & COMMERCIAL PLUMBING SYSTEMS FURTHER INFOMATION

DOMESTIC & COMMERCIAL PLUMBING SYSTEMS FURTHER INFOMATION DOMESTIC & COMMERCIAL PLUMBING SYSTEMS FURTHER INFOMATION Hot and Cold water distribution pipework Sizing of pipework For everyday plumbing in an average sized building a rule of thumb can be used when

More information