Comprehensive Catalog of Blowers Electric Blowers
|
|
- Catherine Stewart
- 6 years ago
- Views:
Transcription
1 Catalog No. A4-3-02E Published August 202 Electric Blowers Fans/Blowers Environmental Equipment Dust Collectors Business Items Comprehensive Catalog of Blowers Electric Blowers Low-noise series High-pressure series Multi-stage series All-purpose series General-purpose series Flange-installed series Stainless-steel series Explosion-proof series Large-sized series Denchoku High-pressure vortex series blowers Gust Blower Agitating/circulating series (Double Volute) Fans/Blowers Turbofans Delturbo Turbo blowers Airfoil fans Sirocco fans Plate fans Axial flow fans with variable blade pitch Kairyu Environmental Equipment Mist collectors Mistresa Portable fans Wind Bag Dust Collectors Dustresa Compact series Small-sized pulse jet series Moveable open-type series Pulse jet series Fumeresa Safety Precautions Before using your product, carefully read the Operating Instruction Manual for a thorough understanding of the proper product usage. The contents of this catalog presuppose transactions and use in Japan only. Providing Hospitality to the Environment Head office: -25 Shinden Kitamachi, Daito City, Osaka Japan Founded: June 29, 950 Sales: 6.6 billion yen (achievements in fiscal 20) sales@showadenki.co.jp The main award histories: Awarded minister of economy in 2006 <IT management promotion section> Distributor locations: Thailand, Brazil, China, France, Germany, India, Indonesia, Korea, Malaysia, Philippines, The U.K., The U.S.A., Vietnam etc... *The contents of this catalog are subject to change without prior written notice. Visit our Website to view the latest version of the catalog. *We are currently delivering CAD data through the Website. Distributor For environment protection, this catalog is printed on recycled paper using soybean oil ink.
2 Download Material from the Website You can download performance curve sheets and dimensional outline drawings from our Website. Here is the procedure: You can search for a product by specifying its model.. Click the Search button on the first page of the window. Enter the model. 2 Model search The corresponding products will be displayed. A click of the button will display detailed product information. 2. Select one of two search methods: Conditional search This function allows you to search for a product by specifying the appropriate product group and specifications/requirements. The corresponding products will be displayed. A click of the button will display detailed product information. Pressing the button corresponding to necessary material will allow you to download the material. Pressing the button corresponding to necessary material will allow you to download the material. Clicking the button on the detailed product information display window will change window control to the window shown at right. - If the desired material is not downloaded by the click, select [Save target in file] by right-clicking to save the material. - You need to use the appropriate CAD software (dfx file) to view CAD data. Catalog Download Click the Catalog Download button on the first page of the window. Enter one-byte alphameric characters into the Air Volume/Static Pressure field (mandatory). Next, click the Search button. Clicking the button on the detailed product information display window will change window control to the following window: - If the desired material is not downloaded by the click, select [Save target in file] by right-clicking to save the material. - You need to use the appropriate CAD software (dfx file) to view CAD data. Pressing the button corresponding to necessary material will allow you to download the material. 2
3 Blower Performance Curve Sheet Blower Performance Curve Sheet TV (Turbo fan) T2V (Turbo fan) B2V (Turbo blower) B3V (Turbo blower) P.5 P.7 P.9 P.0 KT (Airfoil fan) MV (Sirocco fan) PV (Plate fan) GP (Plate fan) P. P.3 P.5 P.7 AD (Axial flow fan) 50Hz AD (Axial flow fan) 60Hz A2D (Axial flow fan) 50Hz A2D (Axial flow fan) 60Hz P.9 P.20 P.9 P.20 AV (Axial flow fan) A2V (Axial flow fan) CM (Agitating fan) CA (Agitating fan) Electric blower Denchoku P.2 P.2 P.23 P.24 P.25 P.27
4 TV-Type Turbo Fan Delturbo with V-Belt Drive A low-pressure high-capacity type. With a multi-purpose impeller applicable to collecting a small amount of dust as well. Actual applicability depends on the quality and amount of dust. Please contact us for further details. Turbo Fan TV Nominal number - Further detailed dimensional outline drawings and performance curve sheets can be downloaded from our Website. Type Uses TV (Nominal number) Dust remover and collector Hot blast circulator Dryer Incinerator Smoke exhaust apparatus Combustion apparatus Boiler Food/chemicals related equipment Air blower/exhaust apparatus for various plant equipment Miscellaneous
5 品名 / 形式 TYPE 風量 VOLUME 静圧 STATIC PRESSURE 回転速度 / 回転数 FAN SPEED 周波数 FREQUENCY 備考 NOTES 電動機 T2V08 MOTOR kw p 電圧 m 3 /min VOLTAGE V 軸動力 kpa SHAFT POWER - kw 温度密度 2225 min - TEMPERATURE 20 DENSITY.2 kg/m 図番 DWG. Hz 印仕様は 仕様書による REFER TO SPECIFICATIONS. CTB0820-Y00 PERFORMANCE CURVE 静圧 St Press. 風量 (m 3 /min) Volume 騒音 Noise 軸動力 Shaft Power 全圧効率 Fan Eff. 作成日 DATE 作成 DRAW 承認 APPROVE May M.MATSUURA Y.UCHIDA 昭和電機株式会社伊賀工場 SHOWA DENKI CO.,LTD. IGA FACTORY T2V2STDMAX4.6K_0.92_0.5 標 4 T2V-Type Turbo Fan Delturbo with V-Belt Drive A middle-pressure high-capacity type. This fan has load-limiting characteristics to prevent motor overloading due to changes in shaft power according to design point. Turbo Fan T2V Nominal number 吸込口正面 m 位置 THE MEASURING POINT AWAY m FROM OPENING 騒音 db(a) Noise 全圧効率 (%) Fan Eff. 軸動力 (kw) Shaft Power 静圧 St.Press. 性能曲線図 - Further detailed dimensional outline drawings and performance curve sheets can be downloaded from our Website. Type Uses T2V (Nominal number) Dust remover and collector Hot blast circulator Dryer Incinerator Smoke exhaust apparatus Combustion apparatus Boiler Food/chemicals related equipment Air blower/exhaust apparatus for various plant equipment Miscellaneous
6 B2V-Type Turbo Blower with V-Belt Drive B3V-Type Turbo Blower An energy-saving noise-reduction type of blower based on Non-Surger concept (Showa Denki's own technology). Nominal number Nominal number Turbo Blower B2V/B3V - Further detailed dimensional outline drawings and performance curve sheets can be downloaded from our Website. Type Uses B2V (Nominal number) For burner combustion air Secondary positive blower Air transport apparatus Dust collector Apparatus related to air pollution control Hot blast blower for use in drying furnaces or annealing furnaces Blower for air conditioning Air supply/exhaust apparatus for various plant equipment and others
7 KT-Type Airfoil Fan with V-Belt Drive The bladed impeller of this fan ensures high efficiency, low noise, and a large air volume. Airfoil Fan KT Nominal number Type KT- (Nominal number) - Further detailed dimensional outline drawings and performance curve sheets can be downloaded from our Website. Uses Air conditioning and ventilation in office buildings and factories Dryers Cooling and air supply/exhaust for equipment Air supply and exhaust for general applications UV apparatus Dehumidifier Wind tunnel test apparatus Coater and others
8 MV-Type Sirocco Fan with V-Belt Drive A large-capacity low-pressure type, best suited to the applications requiring a large volume of air. Sirocco Fan MV Nominal number - Further detailed dimensional outline drawings and performance curve sheets can be downloaded from our Website. Type Uses MIV (Nominal number) Air conditioning and ventilation in office buildings and factories Dryers Cooling and air supply/exhaust for equipment Air supply and exhaust for general applications Wind tunnel test apparatus Miscellaneous
9 PV-Type Plate Fan with V-Belt Drive A large-capacity low-pressure type. This fan is best suited to transporting air from powder or solids and to processing the high-concentration gases that contain dust. Plate Fan PV Nominal number Type PV (Nominal number) - Further detailed dimensional outline drawings and performance curve sheets can be downloaded from our Website. Uses Powder Dust collector for solids/fibrous Boiler Dryer Air transport apparatus Incinerator Fan for potentially corrosive gases Air supply/exhaust for use with various equipment Miscellaneous
10 GP-Type Plate Fan with V-Belt Drive A middle-pressure type. This fan is best suited to transporting air from powder or solids and to processing the high-concentration gases that contain dust. Plate Fan GP Nominal number Type GP- (Nominal number) - Further detailed dimensional outline drawings and performance curve sheets can be downloaded from our Website. Uses Powder Dust collector for solids/fibrous Boiler Dryer Air transport apparatus Incinerator Fan for potentially corrosive gases Air supply/exhaust for use with various equipment Miscellaneous
11 Axial Flow Fan with Variable Blade Pitch (AD type and A2D type) "Kairyu" Motor- Connected type A low-noise type that reduces noise by up to about 5 db (A). Direct driving by direct connection to a motor shaft eliminates the need for maintenance such as belt tension adjustment and belt replacement. In addition, rotating sections are housed inside the machine to ensure human safety. Nominal number Nominal number Nominal number Nominal number Motor-Connected Axial-Flow Fan Type AD (Nominal number) - Further detailed dimensional outline drawings and performance curve sheets can be downloaded from our Website. Uses Air supply and exhaust at tunneling worksites General air conditioning Air supply and exhaust in industrial plants Ventilation in basements Air conditioning at underground parking areas Office buildings air conditioning Miscellaneous
12 Axial Flow Fan with Variable Blade Pitch (AV type and A2V type) "Kairyu" Without in-tube cover V-belt With in-tube cover Since the fan speed can be adjusted by changing a combination of pulleys, multiple units of performance can be set up with one fan. Axial-Flow Fan with V-Belt - This fan is manufactured on a custom-design basis. Please contact our sales department for further details. The telephone numbers and addresses of our sales offices and branches are listed on the back cover of this catalog.
13 CM In-Furnace Agitating Fans with V-Belt Drive A sirocco type of agitating fan. CA In-Furnace Agitating Fans with V-Belt Drive An axial-flow type of agitating fan. Agitating CM/CA - This fan is manufactured on a custom-design basis. Please contact our sales department for further details. The telephone numbers and addresses of our sales offices and branches are listed on the back cover of this catalog.
14 Electric Blowers Electric Blowers A motor shaft directly connected blower of aluminum-molded casing construction. About 20,000 models are available. 50Hz Not useable on ranges. All-purpose series Low-noise series All-purpose series Low-noise series 60Hz High-pressure series General-purpose series High-pressure series General-purpose series General-purpose series Not useable on ranges. Multi-stage series High-pressure vortex series blowers (U2V single-phase) Flange-installed series Not useable on ranges. General-purpose series Multi-stage series Not useable on Not useable on Not useable on ranges. ranges. ranges. Not useable on ranges. Flange-installed series Not useable on ranges. High-pressure vortex series blowers (U2V single-phase) Electric Blowers 50Hz/60Hz Not useable on ranges. High-pressure vortex series blowers (U2V three-phase) High-pressure vortex series blowers (U2S) Not useable on ranges. High-pressure vortex series blowers (U2V three-phase) High-pressure vortex series blowers (U2S) - Further detailed dimensional outline drawings and performance curve sheets can be downloaded from our Website. - Further detailed dimensional outline drawings and performance curve sheets can be downloaded from our Website.
15 Denchoku (Motor-Connected Type of Welded Construction) This type, compared with the V-belt driven type, saves a floor area requirement by about 50% and uses fewer parts and accessories. In addition, it requires no belt tension adjustment. 50Hz 60Hz KD type Airfoil fan KD type Airfoil fan M2D type Sirocco fan M2D type Sirocco fan TD type Turbo fan T2D type Turbo fan TD type Turbo fan T2D type Turbo fan Denchoku 50Hz/60Hz BD type Turbo blower BD type Turbo blower - Further detailed dimensional outline drawings and performance curve sheets can be downloaded from our Website. - Further detailed dimensional outline drawings and performance curve sheets can be downloaded from our Website.
16 Custom-design cases Showa Denki's fans and blowers support various custom designs. Here are examples of actual custom products: Heat-resistant fan connected directly to motor shaft Agitating fan Teflon-coated coupling turbofan In-furnace agitating axial-flow fan Motor shaft-connected fan resistant to high temperatures up to 350 degrees (Turbo fan) : 220 m 3 /min, : 2.58 kpa Motor: 5 kw, 2P, 50 Hz Intake air temperature: 350 deg (maximum) Bearing: Air-cooled type Others: Despite resistance to high temperatures, Denchoku (direct motor shaft connection) specifications provide the highly efficient, compact design. Fan for stirring up air in a tempering furnace (Axial-flow fan) : 400 m 3 /min, : 0.50 kpa Motor: kw, 4P, 60 Hz Material: SUS304 for impeller, shaft, and gas contact region Intake air temperature: 300 deg (maximum) Impeller diameter: 740 mm Bearing: Air-cooled type Others: This fan is of furnace ceiling-mounted construction with its impeller facing downward. Teflon-coated fan highly resistant to corrosion (Turbo fan) : 30 m 3 /min, : 2.94 kpa Motor: 3.7 kw, 2P, 60 Hz Materials: SUS304 for gas contact region and Teflon-coating for casing and intake port Shaft seal: Teflon sheet packing Others: The casing and the bearing case are of separable bolted construction to allow independent replacement of the casing. Fan for agitation in drying furnaces Material: Stainless steel Applications: Agitating the inside of a drying furnace for a uniform temperature distribution Intake air temperature: 50 deg (maximum) Impeller diameter: 630 mm Others: Directly connected to motor Stainless steel sirocco fan Emergency exhaust gas engine fan Wear-resistant fan Wind tunnel test apparatus Sirocco fan for dryers (Sirocco fan) : 620 m 3 /min, : 0.3 kpa Motor: 7.5 kw, 4P, 60 Hz Material: SUS304 for gas contact region This fan was manufactured to suit the dimensional limits of the user equipment. The motor is mounted on top of the casing to implement the compact design. This fan is engine-driven to allow operation even in an emergency such as a power interruption. (Turbo fan) : 45 m 3 /min, : 2 kpa Engine output: 4.3 kw Shaft seal: Bypass labyrinth seal (Construction in which the high-pressure gas at the shaft seal is suctioned using an intake-side vacuum pressure to minimize leakage from the shaft seal) Others: Anti-vibration rubbered frame and intake/outlet expansion coupling (Nylon tarpaulin) Plate fan designed to withstand wear (Plate fan) : 3 m 3 /min, :.75 kpa Motor: 3.7 kw, 4P, 50 Hz Casing: Inner surface treated by wear-resistant thermal spraying. A chromium-based alloy is sprayed to a thickness of 0. mm. Impeller: Treated by wear-resistant thermal spraying. A hard build-up welding rod based on tungsten carbide is used on the flow region. Intake port: Totally removable construction The casing and the bearing pedestal are of separable construction to allow replacement of the casing. This wind tunnel test apparatus uses the variable blade pitch axial-flow fan "Kairyu" of 900 mm in diameter. (Approx. size: 8.3 m x 3.2 m) This test apparatus uses the high-efficiency large-capacity variable blade pitch axial-flow fan "Kairyu". Inside the wind tunnel, a wire mesh and straightening plates, as well as a honeycomb structure, are provided to maintain a uniform in-channel cross-sectional airflow for straightening. The diameter of the outlet port is 500 mm, and the maximum velocity is 50 m/s (80 kmph). Custom-design cases
17 Technical Information/Data Technical Information/Data 2 Temperature Conversion Precautions for selection The fan/blower performance curve sheets in the catalog are based on a standard state of 20 C. Even for identical fans/blowers, when the temperature of the gas being to be handled changes, specified points (design criteria) will change as follows per the following calculation expressions: : : P2 = P Q2 = Invariant (m 3 /min) 273+t 273+t2 List of temperature conversion coefficients 273+t Shaft power: L2 = L (kw) 273+t2 P = Specified static pressure at a gas temperature "t" of C P2 = Specified static pressure at a gas temperature "t" of 2 C L = Specified shaft power at a gas temperature "t" of C L2 = Specified shaft power at a gas temperature "t" of 2 C Air changes in volume according to temperature and pressure, and will expand when the temperature rises. When air expands, mass will decrease even if the volume remains the same. However, since the air volume, as expressed in terms of m 3 /min or m 3 /h, is a volumetric flow rate that represents the volume per unit time, the air volume will remain invariant, even when the temperature rises. Temp ( C) Coefficient Temp ( C) Coefficient Temp ( C) Coefficient Temp ( C) Coefficient Intake Air Temperatures and the Types of Bearings Intake air temp Bearing type Construction Lubrication Fan/blower coating Guards coating Above -0 C, but up to 50 C Standard Heat-resistant Heat-resistant (Air-cooled) Heat-resistant (Water-cooled) Shaft seal Above 50 C, but up to 50 C Shaft seal Above 50 C, but up to 350 C Shaft seal Cooling fan Above 350 C, but up to 650 C Depends on model and speed Shaft seal Cooling fan Standard grease Heat-resistant grease Heat-resistant grease Heat-resistant grease Standard (2.5Y6/2) Heat-resistant silver (Standard for up to 80 C) Heat-resistant silver Heat-resistant silver Munsell 2.5YR 6/3 Water-cooling metal Shaft Seal Showa Denki's standard shaft seals The shaft seal refers to that of the region at which the fan/blower penetrates the casing. The shaft-sealing device is needed to prevent the gas inside the casing from leaking from the shaft seal, or to prevent the atmosphere from flowing from the shaft seal into the casing. If the kind of gas to be handled is standard air and the static pressure is up to nearly kpa, there is no need to provide the shaft-sealing device. In general, packings and/or labyrinth seals are used in fans. Packing seals (For fans/blowers: Iga Factory products) Kind of seal Glass cloth Types of fan/blowers Low-pressure and middle-pressure turbofans/plate fans V-rings (For electric blowers: Daito Factory products) The V-ring, made from 00% homogeneous rubber, has its ribs and body coupled via hinges. The V-ring is mounted for sealing against dust and moisture, and this ring is provided as a standard component in virtually all middle-size and larger electric fans and blowers manufactured at the Daito Factory. Optional Shaft Seals Labyrinth seal (Non-contact seal) This seal forms very small clearances between a rotor and a stator. The gas usually leaks and decreases in pressure while the flow of the gas alternates between the relatively wide clearances and relatively narrow ones of the formed clearances. The seal utilizes the event. This type of seal is used in the cases that the surface velocity of the fan/blower shaft exceeds 2 m/s and that a slight amount of gas leakage from the casing is allowed. Advantages: Heat-resistant type - No sections suffer wear because of non-contact. - Easily responsive to thermal expansion. Disadvantages: - Sealing performance during slow rotation and under a stopped state is relatively low. Mechanical seal (Contact seal) This seal conducts sealing on two planes perpendicular or almost perpendicular to the fan/blower shaft. One of the planes is used as a rotary plane, and the other is used as a stationary plane. Packings are also referred to as edge seals, and of these seals, shaft-sealing devices having a buffer mechanism to maintain the to-be-sealed planes in an appropriate contact status are referred to as mechanical seals. Advantage: - Virtually no leakage Disadvantages: - Complex in structure, and expensive. - Difficult to replace. Casing interior Fan/blower shaft Casing interior Fan/blower shaft Outside Inside B Seal ring Floating sheet Packing seal d d2 d d3 d2 : Maximum diameter d3 : Minimum diameter B Coil spring Technical Information/Data
18 Technical Information/Data 3 Technical Information/Data 4 Construction of Fans and Blowers Energy-saving Effects of Reducing the Fan/Blower Speed by 0% Tapered shaft/holes adopted for fan/blower mounting fixtures Advantages () Saves impeller mounting/dismounting time. (2) High-temperature specifications: Any effects of thermal distortion on hub holes and shaft are minimized. (3) Stainless steel specifications: Hub hole/shaft fusion (scuffing) can be prevented. Applicable models T/T2-2 to 36 Cantilever type, Belt-driven type, Coupling-driven type B2-04 to 0, B3-05 to 0 Cantilever type, Belt-driven type, Coupling-driven type M-4 to 32 Cantilever type, Belt-driven type, Coupling-driven type KT-30 to 90 Cantilever type, Belt-driven type, Coupling-driven type V-belt drive Directly connected to coupling Denchoku standards Details of impeller mounting fixture T,T2V08 to 0 Details of impeller mounting fixture T,T2V40 Part No Part No Part No Part Name Intake port Impeller Casing Bearing Bearing housing body Bearing Bearing housing cover Casing shaft seal Shaft Pillow-type unit Bearing guard Belt guard Parallel key for V-pulley Holder for V-pulley Bolt for holder Hub-locking nut Lock washer Impeller hub Parallel key for impeller Common base V-pulley Bolt for holder Holder for impeller Hexagon socket setscrew Holder for impeller Casing Intake port Impeller Part Name Parallel key Holder setbolt Holder Shaft seal Counter-drive bearing Shaft Drive bearing Bearing guard Coupling guard Coupling Motor Bearing/motor base Base Part Name Casing Impeller Intake port Intake case flange Parallel key Holder Holder setbolt Motor Packing Outlet case flange Shaft seal Shaft seal clamp Shaft guard Motor base Impeller hub Parallel key Hex socket setscrew Shaft-locking nut Lock washer Material FC200 FC200 Non-asbestos S45C Shaft * Maintainability significantly improves. S45C FC200 S45C FC200 SCM435 FC200 Material, High-strength steel S45C FC200 Non-asbestos S45C Material S45C Motor manufacturer's standards Non-asbestos Qty 2 2 sets set 2 set Qty 2 2 set Qty set Storage of the Fan/Blower Precautions for storage If the fan/blower is stored or shut down with the rotating shaft of the impeller remaining stopped for at least about three months in succession, contact sections between the balls of the bearing and the track surface may suffer oil film breakage, depending on the season or the environment. If this is the case, unusual sounds will result from unwanted events such as corrosion. Remove the bearing guard periodically (at least once a month) and manually rotate the shaft through about 0 turns to prevent bearing corrosion. Storage location () Store your product at a dry location with minimum changes in indoor temperature. (2) Shroud your product with waterproof sheeting to protect the product from moisture, oils, dust, and the like. (3) Avoid storage in a place exposed to direct sunlight, strong vibration or heat, and the like. Also, avoid contact with a cold wall. Roller Ball Dropping Sound The roller ball dropping sound of the fan bearing features the following () Upon moving from a non-loaded area into a loaded area, the roller becomes free to move and the balls start to roll by gravity, thus hitting the retainer to generate the sound. (2) The magnitude of the sound varies from product to product. (3) The sound level increases and decreases. Bearing clearances Quadratic system loss curve Decreases in air volume reduce pressure loss in proportion to the square of the air volume. () The internal clearances of the heat-resistant bearings and other bearings of the B2V and B3V blowers which rotate at high speed are preset to be C3 clearances allowing for expansion due to bearing temperature rises to at least about 50 C. (2) Since the C3 clearances are large in comparison with CN clearances, the roller ball dropping sound may occur under relatively low bearing temperatures. (BkW) Shaft power Fan/blower speed 20 min- 02 min- 0% down System air volume 200 m 3 /min 080 m 3 /min Shaft power 99 kw 72 kw 0% down 27% down Technical Information/Data
Comprehensive Catalog of Environmental Equipment
Catalog No. E-03-02E Published March 2014 Comprehensive Catalog of Environmental Equipment Providing Hospitality to the Environment For Creating a Pleasant Workplace Environment For collecting mist generated
More informationComprehensive Catalog of Environmental Equipment
Catalog No.W-02-01E Published in August 2015 Comprehensive Catalog of Environmental Equipment Providing Hospitality to the Environment For Creating a Pleasant Working Environment Windbag Proposals for
More informationPUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...
PUMPS FOR INDUSTRY CONTENTS: The Vertical Pump Specialists Introduction & User List Product Overview Vertical Process Pumps... Series 600 Vertical Sewage Pumps... Series 700 Vertical Sump Pumps... Series
More informationFuji Electronic VFC 084P-5T
Fuji Electronic VFC 084P-5T Fuji s complete line of ring compressors is designed to meet the most critical application requirements. Each features an impeller, mounting base and housing manufactured of
More informationHigh Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)
High Plume Blowers Suggested Specification Section 15500 (Master Format 1996) Suggested Specification Section 23 38 16 (Master Format 2004) PART 1 GENERAL 1.01 WORK INCLUDED High Plume Laboratory Exhaust
More informationFans: Features and Analysis
Technical Development Program COMMERCIAL HVAC EQUIPMENT Fans: Features and Analysis PRESENTED BY: Michael Ho Version 1.2 Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Section
More informationOriginal instructions. Operation Manual & Cautions
Original instructions Operation Manual & Cautions Thank you for purchasing the Mistresa from Showa Denki. This manual explains the specifications for the [Mistresa units from CRN Series]. Please read the
More informationConstruction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA
Construction Standards Page 233423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified
More informationwe make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)
we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) www.blowtech.in we make air move Blowtech Air Devices Pvt. Ltd. was founded in 1988 and quickly established
More informationSPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS
SECTION 23 34 16 CENTRIFUGAL HVAC FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Drawings and general provisions of the contract, including General and Special Conditions and Division 01 Specification
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS
PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Placement within a mechanical room is required for all major mechanical equipment. Only small units may be roof-mounted, and shall be made as inconspicuous
More informationBrown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS
SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett
More informationUNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:
SECTION 233423 - HVAC POWER VENTILATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 PERFORMANCE REQUIREMENTS A. Operating
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL TUBE AXIAL FANS BTA, WTA, HTA, DDA The purpose of this manual is to aid in the proper installation and operation of the fans. These instructions are intended
More informationComplete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A
Publication No. WT-CSX-0616A Central Station Air Handling Units Complete HVAC Capability Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels
More informationan ISO 9001 Company Bulletin PR-112
an ISO 9001 Company Bulletin PR-112 Airfoil Fans SINGLE WIDTH DOUBLE WIDTH SQUARE SQA FANS DIRECT DRIVE FANS Known for high efficiency, low sound levels, and low horsepower, the Design 51 fan is used extensively
More informationIntroduction to Fans. The Basics of Fan Principles and Terminology
Introduction to Fans The Basics of Fan Principles and Terminology Airflow Principles A fan is a rotating device that creates pressure differential that results in air movement Pressure rise in a fan Downstream
More informationSECTION AIR HANDLING UNIT
SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR
More information1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans
1 - mj,, Donkin Fans Majax-2 Aerofoil Axial Flow Fans - IW '~AJAX-2 GENERAL SPF ~IFICATION Majax-2 axial flow fans are manufactured in diameters ranging from 315mm to 2000mm (available in 2250mm on request),
More informationMultistage Centrifugal Blowers
Multistage Centrifugal Blowers Multistage Centrifugal Blowers In order to meet all the requirements for air and gas applications, Ingersoll Rand provides a new generation of Hibon Multistage Centrifugal
More informationDS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP
DS series Industrial End Suction Pumps ISO/DP 5199 www.sterlingpumps.com.au DS series Capacities from: Heads from: 340 to 5,680 m3/h (1,500 to 25,000 USPGM) 21 to 106 metres (70 to 350 feet) Power range
More informationPAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s
PAPANTONATOS P u m p s s e r v ic e & e n g i nee r in g We supply clean water and remove waste water s e w a g e p u m p s submersible pumps The Company QUALITY WHICH REDUCES PUMPING COSTS For over 45
More informationModular Supply Make-Up Air Unit
Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features
More informationTurning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS
Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST S Model TCBS CATALOG AX220 May 2013 TubeaxialFans Model TCBS The Twin City Fan & Blower model TCBS is a belt driven tubeaxial fan that is
More informationLN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.
LN series Horizontal Split Case Pumps Double Volute. Single Stage www.sterlingpumps.com.au LN series Sizes: 6 to 42 Capacity to 12,500 m³/h Heads to 190 metres A rugged, single stage, double volute horizontal
More informationSelecting the Correct Fan
Selecting the Correct Fan Ryan B. Johnson Air Purification Company Sales Engineer Member, ASHRAE Pikes Peak Chapter rjohnson@airpurificationcompany.com 1 Your Speaker circa 1998 Fan Types Applications
More information4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction
4VH and 4VHX 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction DURABLE MOTOR WILL DELIVER MANY YEARS OF RELIABLE SERVICE Oil-filled motor for maximum heat dissipation
More informationETP Series - Self Priming Pumps
ETP Series - Self Priming Pumps ETP SERIES Decades of experience in development & manufacturing of injection Moulded Polypropylene Corrosion Resistant Pumps. Design philosophy is to design pumps that are
More informationCentrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series
Centrifugal Chiller High Efficiency GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency Centrifugal Chiller HC-F-GFG-SSC Series (Super High Efficiency Type) HC-F-GXG-S
More informationHorizontal Split Case Pumps Type U
Horizontal Split Case Pumps Type U 7.1 7.2 Stage U Type Pumps Features: Axially Split Case Design Range from 20M 3 /Hr to 600M 3 /Hr Two Stage Pump Single Suction Twin Volute Casing Design Closed type
More informationMultistage Centrifugal Blowers
Multistage Centrifugal Blowers Multistage Centrifugal Blowers In order to meet all the requirements for air and gas applications, Ingersoll Rand provides a new generation of Hibon Multistage Centrifugal
More informationFAN TYPES CENTRIFUGAL FAN Forward Curve Centrifugal Fan
FAN TYPES In order to cover a wide range of applications, fans are manufactured in a variety of type. They can be classified under three general types : (a) Centrifugal, (b) Axial and (c) Mixed flow. Table
More informationHIGH PRESSURE DOUBLE CASE PUMPS
HIGH PRESSURE DOUBLE CASE PUMPS Horizontally Split Inner Casing, Multi Stage For Boiler Feed, Process and Other High Pressure Services CS1860EE Models HSB/HDB API 610 HIGH PRESSURE DOUBLE CASE PUMPS Horizontally
More informationIndustrial Fans & Blowers
Industrial Fans & Blowers IN-LINE FANS ADD DIRECT DRIVE TUBEAXIAL FANS FEATURES & BENEFITS Spark resistant, cast aluminum airfoil axial impeller Aerodynamically efficient performance Factory set adjustable
More informationFeaturing Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut
Featuring Ozone-safe HFC134a Hitachi Centrifugal Chillers NEW GXG-S Series GSG-S Series Debut Centrifugal Chiller New GXG-S, GSG-S Series Debut High-efficiency New series Centrifugal Chillers that use
More informationPUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...
PUMPS FOR INDUSTRY CONTENTS: The Vertical Pump Specialists Introduction & User List Product Overview Vertical Process Pumps... Series 600 Vertical Sewage Pumps... Series 700 Vertical Sump Pumps... Series
More informationInstruction Manual for Dust Collector
YFAA11A-076ERe2 Instruction Manual for Dust Collector Dust Collector with Work Table Workrésa (WRM) Introduction Thank you for purchasing our Showa Denki s Dust Collector with Work Table (WRM) this time.
More informationWIDEST RANGE OF INDUSTRIAL & AIR CONDITIONER PACKAGED FAN!
WIDEST RANGE OF INDUSTRIAL & AIR CONDITIONER PACKAGED FAN! FANTECH s full ranges of industrial and buiding ventilating fan widly used in industry process Plant & refrigeration, packaged air conditioner
More informationCentrifugal Fans, Non-Overloading, Backward Inclined
BACKWARD INCLINED CENTRIFUGAL FANS Centrifugal Fans, Non-Overloading, Backward Inclined MVA, MVZ, MVX & MVW Series with laminar blades MAVA, MAVZ & MAVX Series with aerofoil blades Features The combination
More informationSECTION (15833) - HVAC POWER VENTILATORS
PART 1 GENERAL 1.01 SUMMARY SECTION 23 34 23 (15833) - HVAC POWER VENTILATORS A. Section Includes: 1. Centrifugal Roof Ventilators. 2. Up-blast Roof Exhaust Fans (Kitchen Hood Exhaust). 3. Ceiling-Mounted
More informationCAP SERIES SEWAGE AND WASTE WATER PUMPS
Part 8 CAP SERIES SEWAGE AND WASTE WATER PUMPS TECHNICAL SPECIFICATIONS : Turbosan CAP series consists of centrifugal sewage and waste water pumps. They are used for pumping muddy liquids like sewage and
More informationA. Codes and Standards that are Standard at the University:
PART 1: GENERAL 1.01 Purpose: 1.02 References: 1.03 Requirements: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The
More information侧进式搅拌器. 产品介绍 Product introduction
产品介绍 Product introduction DIC system builds powerful industrial mixing and separation system that improve tank utilization, promote faster mixing and separation, improve operation efficiency and reduce
More informationAxial flow fan AXICO ANTI-STALL
Product data sheet: AXICO ANTI-STALL Axial flow fan AXICO ANTI-STALL Model FPAC and FPMC axial flow fans with controllable pitch blades. Air flow range: 3-110 m³/s (10.000 400.000 m³/h). Pressure rise:
More informationRC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit
SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit RCW-54CB RO-50CA RC-54CA RO-50CA RC-54HA RO-50HA CONTENTS SPECIFICATIONS OUTLINE AND DIMENTIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM
More informationMCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS
MCF 00 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS MCF 00 CENTRIFUGAL FAN FOR COMBUSTIBLE GASES MCF 00 centrifugal fan for biogas, natural gas or combustible gases, in conformity to the
More informationSubmittal Data Performance Data Electrical Data
ERMS Series Submittal Data Submittal Data Unit Designation: Job name: Architect: Engineer: Contractor: Performance Data Revision: 07/01/11 Cooling Capacity: EER: Heating Capacity: COP: Ambient Air Temp:
More informationInternal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.
A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall
More informationAIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.
SECTION 15855 AIR HANDLING UNITS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15240 - Vibration Isolation. 2. 15885 - Air Filtration Equipment. 3. 15890 - Ductwork. 1.02 REFERENCES A. Air Moving
More informationDirect Fired Heater Model AD Specification
Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI
More informationTP /4-A-F-A-BQQE 400D 50HZ
GRUNDFOS DATA BOOKLET TP 15-7/-A-F-A-BQQE D 5HZ Grundfos pump 989838 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/989838/tp-15-7--a-f-a-bqqe.html
More informationMidea VFD Centrifugal Chiller Technology
Midea VFD Centrifugal Chiller Technology Content Why VFD VFD centrifugal chiller technology Solution 2 HVAC major issues Energy conservation Global warming reduction 3 Why VFD No Compressor A/C Lower GWP
More informationPropeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!
Propeller Fans Industrial And Commercial Fans Belt And Direct Drive Your Clean Air Source! MODEL PVL EXHAUST FANS Application Economical fans for use in kitchens, laundries, taverns, bakeries and also
More informationPlenum Fans. Model HPA. Direct Drive
Plenum Fans Model HPA Direct Drive October 2012 Quiet & Efficient HPA Plenum Fans Greenheck s modular plenum fan, model HPA, is designed and engineered to provide superior performance and reliability in
More informationCOMBIFAB F Fan The flexible fan for dust extraction systems in all industries
COMBIFAB F Fan The flexible fan for dust extraction systems in all industries Combifab F Fan Our Combifab F range of fans consists of four different fans solving all kinds of dust extraction applications
More informationChore-Time Fan Guide For Tunnel and Other Applications
Chore-Time Fan Guide For Tunnel and Other Applications Chore-Time s Fiberglass and Galvanized Fans Provide Efficiency and Performance Diameters available through 54 Inches (137.2 cm) Chore-Time s TURBO
More informationAir Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)
http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made
More informationEvase Vaneaxial Fans 500mm to 1400mm Diameter Bulletin ECA 10-07
www.howden.com Evase Vaneaxial Fans 500mm to 1400mm Diameter Bulletin ECA 10-07 Evase Vaneaxial fans by Howden can save energy over the installed life of the system by recovering the kinetic energy contained
More informationDAE Systems. Fan Selection Guide. Section 1: Terminology
DAE Systems Fan Selection Guide Section 1: Terminology CFM : Cubic Feet per Minute Technical Terms This refers to the amount of air a fan is able to move. Pressure Inches of water is a common method of
More informationB. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).
Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage
More informationReducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable.
http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Reducing Valve Direct Mount Type with Pressure Gauge 232 Direct Mount Type (Compact size) Pressure Gauge is selectable. Display
More informationA. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:
SECTION 15860 - FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR MECHANICAL
More informationLOW STATIC HYDRONIC DUCTED UNIT
LOW STATIC HYDRONIC DUCTED UNIT PDWA-~AC SERIES PDWA(4R)-~-V-MEDC PDWA(4R)-~-V-MEEU PDWA(R)-~-V PDWA(R+1)-~-P Model cooling capacity( KW) at Medium Speed cooling capacity (KW) at Medium Speed cooling capacity
More informationTURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual
TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive Installation & Operator s Instruction Manual July 1998 MV1383B Chore-Time TURBO TM Fan Extended Warranty Chore-Time Equipment warrants new TURBO
More informationMasters in energy efficiency
KBA Metal Decorating Masters in energy efficiency 2-Piece Ovens The new benchmark in economy and efficiency GB 2-Piece Ovens Optimised drying solutions for 2-piece cans KBA-MetalPrint GmbH KBA-MetalPrint
More informationInternational Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries
International Reactor Bulletin 1100 Corporation Standard and Custom Reactors for the Chemical Process Industries 2 International Reactor Corporation 521 Kiser Street Dayton, Ohio 45404-1641 Phone: 937-224-4444
More informationKRS data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet
KRS822-50 data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429
More informationINSTRUCTION AND REPAIR MANUAL
SECTION 6 ITEM 390 DATED JANUARY 2003 SUPERSEDES SECTION 6 ITEM 390 DATED OCTOBER 2000 INSTRUCTION AND REPAIR MANUAL SERIES 390 6 The 390 Series is a superior commercial Multi-Stage Vertical In-Line Centrifugal
More informationAir Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)
http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made
More informationMXI Mixed Flow Inline Fan
MXI Mixed Flow Inline Fan PRODUCT GUIDE PennBarry Your Single Source for Commercial & Industrial Supply & Exhaust Fans www.pennbarry.com TABLE OF CONTENTS INTRODUCTION 3 CERTIFICATIONS & LISTINGS 4 MIXED
More informationSKYPAK II, 3 Ton Series, gives you a
SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall
More informationSKYPAK II, 3 Ton Series, gives you a
SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall
More informationA. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.
15855 AIR HANDLING UNITS SPECIFIER: CSI MasterFormat 2004 number: 237313 PART 1 GENERAL 1.1 SUMMARY A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution
More informationFamily Curve. Submersible Grinder Pumps 1¼" and 2" Discharge. Effluent/Grinder Pumps.
Family Curve Submersible Grinder Pumps 1¼" and 2" Discharge 7 11/0 Submersible Vortex Grinder Pumps SGV, 2HP, Double Seal, Oil-Filled Word File FILE: SPEC4 SCOPE: Furnish and install submersible grinder
More informationHOFFMAN & LAMSON ENGINEERED VACUUM SYSTEMS
HOFFMAN & LAMSON ENGINEERED VACUUM SYSTEMS ENGINEERED VACUUM SYSTEMS FOR INDUSTRIAL APPLICATIONS Anchored in tradition, the Hoffman & Lamson Engineered Vacuum System line-up continues a century long commitment
More informationPulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities
Pulse Jet ASTEC PULSE JET BAGHOUSE for Asphalt Facilities ASTEC PULSE JET BAGHOUSE FOR ASPHALT MIXING PLANTS Astec baghouses deliver superior performance and efficiency, while helping your plant meet
More informationCENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components:
Pumps DOE-HDBK-1018/1-93 CENTRIFUGAL PUMPS CENTRIFUGAL PUMPS Centrifugal pumps are the most common type of pumps found in DOE facilities. Centrifugal pumps enjoy widespread application partly due to their
More informationWarranty Details page 2. Pump Description & Technical page 3 Specifications. Transportation, Storage & Installation page 4. Pump Maintenance page 5
5 . Manual Contents Warranty Details page 2 Pump Description & Technical page 3 Specifications Transportation, Storage & Installation page 4 Pump Maintenance page 5 Wet end Dismantling page 6 Wet end Assembly
More informationMultistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR
Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR General DICKOW-pumps of series HZ/HZA are single- or multistage centrifugal pumps with shaft sealing. Application HZ/HZA-pumps are applied
More informationDirect Gas-Fired Make-Up Air
Direct Gas-Fired Make-Up Air Model TSU Heavy Duty, High Airflow Applications Manufacturing and Industrial Facilities Up to 64,000 cfm August 2012 Products Model TSU Direct Gas-Fired Make-Up Air Unit The
More informationSIHI LPH-X - Liquid Ring Vacuum Pump One Stage
- Liquid Ring Vacuum Pump One Stage LPH 60527 Pressure Range: Suction Range: 120 to 1013 mbar 200 to 800 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with
More informationTUNNEL FANS STANDARD AND HOT SMOKE
TUNNEL FANS STANDARD AND HOT SMOKE NovAx tunnel fans PRODUCT FACTS Product Novenco tunnel fans are produced with either round or rectangular outer dimensions. Both types are made in unidirectional (AUC
More informationROTARY DRYER CONSTRUCTION
ROTARY DRYER The Rotary Dryer is a type of industrial dryer employed to reduce or to minimize the liquid moisture content of the material it is handling by bringing it into direct contact with a heated
More informationFeaturing Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut
Featuring Ozone-safe HFC134a Hitachi Centrifugal Chillers NEW GXG-S Series GSG-S Series Debut Centrifugal Chiller New GXG-S, GSG-S Series Debut High-efficiency New series Centrifugal Chillers that use
More informationYAH SERIES FAN COIL UNITS
YAH Series Fan Coil Units Johnson Controls YORK YAH ceiling mounted cabinet fan coil units are terminal points of central air-conditioning systems. They are designed for fresh air units or to cool, heat,
More informationBlock Macerators Series ABM-2-S
Block Macerators Series ABM-2-S Usage Macerators chop solids conveyed in liquids; materials like wood, textiles, plastics, paper, rubber, bones, skins, glass etc., so that they may be pumped. After treatment
More informationCENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING
CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING TM MITTAL ENGINEERING M i t t a l E n g i n e e r i n g i s o n e o f t h e l e a d i n g m a n u f a c t u r e r s q u a l i t y e n g i n e e r i n g
More informationR7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units
TECHNICAL SPECIFICATIONS R7DA Series 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units 5.4 ISMRE Commercial System 81% Steady State Efficiency Standard Features Fits Pre-Existing Curbs High-Efficiency Low
More informationMultistage Centrifugal Blowers
Multistage Centrifugal Blowers Multistage Centrifugal Blowers In order to meet all the requirements for air and gas applications, Ingersoll Rand provides a new generation of Hibon Multistage Centrifugal
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.
More informationUNIVERSITY OF MISSOURI Central Station Air-Handling Units March
GENERAL: 1. This section provides criteria for the design and installation of air handling units. DESIGN GUIDELINES: Design General 1. Location 1.1. For new construction, and existing buildings where possible,
More informationIEC- Direct-driven radial fans with IEC-Standardmotor
EHND / ERND / ERNE / Contents. / Page 1. / Safety... 2 2. / Description... 4 3. / Condition of use... 4 4., / Storage, Transport... 5 5. / installation... 6 6. / operation... 8 7. / maintenance... 9 8.
More informationTURBO AND HIGH PRESSURE REGENERATIVE BLOWERS
NEW! TURBO AND HIGH PRESSURE REGENERATIVE BLOWERS Turbo Blowers Blower housings from cast aluminum, closed impellers from sheet aluminum, maintenance-free squirrel cage rotor motors of our own manufacture
More informationBoiler Draft Equipment
Boiler Draft Equipment Learning Outcome When you complete this module you will be able to: Discuss, sketch and describe the basic equipment used to supply combustion air to a boiler furnace. Learning Objectives
More informationTEXTILE AIR ENGINEERING EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY
EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY AUTOMATIC ROTARY AIR FILTERS Self-cleaned rotary air filter can be used in various applications. General area of use is textile plants for filtering
More informationCenteral Station Air Handling Unit
Centeral Station Air Handling Unit CA Series www.windind.com www.windind.com The product range includes double skinned Air Handling Units, double skinned Fan Coil Units, and custom designed packaged roof
More informationCustomized Industrial Products
Customized Industrial Products Product Catalog Large Walk-in Type Drying Oven Large Size Autoclave Large Size Fine Oven Targeting Productivity Improvement Yamato offers customization of products based
More informationPENGUIN SERIES HSC PUMPS INTRODUCTION
PENGUIN Installation & Maintenance SERIES HSC PUMPS MODELS HSC-1/4 HSC-1/2 HSC-3/4 HSC-1 HSC-2 HSC-3 SEALS S - Single D - Double M - Single/Multi-Stage INTRODUCTION Penguin 316 stainless steel centrifugal
More informationModular Air Handling Unit
MAHUs are modular so that they have the flexibility to add components as required. The 3rd generation Midea MAHU adapts unitary structure design, more outstanding cold-bridge free performance, lower air
More informationSECTION STEAM CONDENSATE PUMPS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 22 23 STEAM CONDENSATE PUMPS SPEC WRITER NOTES: 1. Delete between // ---- // if not applicable to project. Also delete any other item or paragraph not applicable
More information