HARTZELL. Tempered Air Heating Equipment. Hartzell Fan, Inc., Piqua, Ohio

Size: px
Start display at page:

Download "HARTZELL. Tempered Air Heating Equipment. Hartzell Fan, Inc., Piqua, Ohio"

Transcription

1 Tempered Air Heating Equipment Series GFR GMC GMP SAH SCH SFC SMC SMP 77 78H 78V Hartzell Fan, Inc., Piqua, Ohio January 2011

2 Index Hartzell Model Code Explanation Page 2 Pictorial Table of Contents Page 3 Tempered Air Heating Equipment Function Page 4 Installation Configurations Page 5 Series GFR FC Centrifugal Recirculation Gas Unit.... Pages 6-9 Series GMP (Propeller) and GMC (Centrifugal) Gas Unit Pages Series 78H and 78V Econo Gas Units Pages Series 79 Gas Fired Door Heater Pages Hartzell Model Code Explanation Motor Horsepower Horsepower 1 11/ / Code Letter H I J K L M N O P Q R S T U V W X Y Z How To Use Model Code Index: Example Assume a performance of 2,000,000 BTU/Hr and 20,000 CFM at 0 Ext. S.P. at standard conditions, with filters is required. Reading the Rating Table on Page 14, we find a Series SMP Steam Make-Up Air Propeller Fan Assembly with a 44 fan at the required performance. The model code can be constructed as follows: Type is Production (code A), Series is SMP, Size is 44, Number of blades is 3, Blade code is L. The fan is made of steel (code ST) with a totally enclosed fan cooled motor (code FC), motor HP is 3 (code K) and RPM/Voltage is 1750/460/60/3 (code 3). Notes: * 3 = Drive arrangement for DWDI or FC, belt drive centrifugal fans, AMCA standard = Close couple belt drive, propeller fans ** 1 = Centrifugal fan, Class I, per AMCA standard , product definitions varies = Propeller fan number of blade for propeller *** Airflow delivery in standard density (0.075 lbs/ft 3 ) This Tempered Air Bulletin bulletin lists the majority of Hartzell s line of Gas and Stream Intake Units and accessories. More than 70 Hartzell offices can **** provide ST = specific Steelperformance and installation data to meet your requirements. Call your Hartzell representative for assistance. Visit our website () GL = Galvanized or Steel call toll-free for the name of your Hartzell representative... GN = Galvannealed Steel Series 811 Gas Shaft Heater Page 23 Series SFC Centrifugal Steam Heater Pages Series SMP Propeller Fan Steam Unit Pages Series SMC Centrifugal Steam Unit Pages Series SAH (Axial) and SCH (Centrifugal) Face & Bypass Pages Series 77 Steam Unit Heaters Pages Options and Accessories Pages Type A S M P L 2 0 S T FC K 3 A - Production Item I - IRI Plumbing (Gas only) F - FM Plumbing (Gas only) Product Series Arrangement* Size (nominal wheel diameter, inches) No of Blades/Class** Blade/Wheel Unit CFM*** Material of Construction**** Motor Enclosure Motor Horsepower Motor RPM/Phase All other informational fields must be filled with hyphens/dashes ( ) if they are not applicable to the fan being considered. Motor RPM/Volt/Phase 2 = 3450/230/460/60/3 3 = 1750/230/460/60/3 4 = 1140/230/460/60/3 5 = 870/230/460/60/3 6 = 690/230/460/60/3 7 = 575/230/460/60/3 This bulletin lists Hartzell s complete line of Make-Up Air Units and accessories. More than 70 Hartzell offices can provide specific performance and installation data to meet your requirements. Call your Hartzell representative for assistance. Visit our website () or call toll-free for the name of your Hartzell representative

3 Tempered Air Heating Equipment Series GFR FC Centrifugal Gas Air Make-Up Heater with Air Recirculation Page 6 Series GMP/GMC Propeller/Centrifugal Gas Air Make-Up Heater Page 10 Series 78H/78V Econo Gas Heater Page 19 Series 79 Gas Fired Door Heater Page 21 Series 811 Gas Shaft Heater Page 23 Series SFC Centrifugal Steam Heater Page 24 Series SMP Propeller Steam Make-Up Air Page 26 Gas Fired Standards and Certifications F.M. I.R.I. Series SMC Centrifugal Steam Make-Up Air Page 30 Series SAH/SCH Steam Face and Bypass Units Page 32 Series 77 Steam Unit Heaters Page 36 Factory Mutual Engineering and Research encompasses the Factory Mutual Research Corporation and the Factory Mutual Engineering Association. These groups provide research, standard development and product testing and approval. In addition, FMEA provides property loss prevention consulting services. Hartzell Direct Gas Fired Forward Curved Make-Up Air Heaters are available built to FM loss prevention guidelines, for field acceptance by FM for insurance purposes. Industrial Risk Insurers is a highly respected risk insurance company. Hartzell Gas Fired Make-Up Air Heaters are available built in accordance with the designs and features set forth in I.R.I. Publication No. IM Space Heaters. 3

4 Function Air removed by exhaust systems must be replaced systematically by outside air. If this is not done, the exhaust system, while in operation, creates a negative pressure inside the building. The negative pressure conditions created reduce the overall effectiveness of the exhaust and ventilating systems of the entire plant. Smoke, fumes or corrosive vapors from manufacturing processes will build up, making personnel uncomfortable and reducing their efficiency. In the winter months, make-up air provides a dual function of supplying tempered outside air for heating as well as air to balance the system. If a negative pressure exists, hot and cold spots are likely to develop since airflow is not uniform throughout the building. Workers near windows and other openings are subject to cold drafts. The infiltration of cold air overloads the existing heating system in the winter, thus reducing its efficiency. The installation of a heated make-up air system will eliminate these negative pressure problems in the plant. Both the central heating system and the exhaust or ventilating system will be restored to full operating efficiency. Advantages of make-up air in your plant: 1. Worker comfort and efficiency increase because dust, fumes and contaminants can be removed efficiently by the existing exhaust systems. 2. Bothersome drafts and cold spots are eliminated. 3. Stacks on ovens, boilers and other direct or indirect fired equipment are restored to full efficiency. 4. Overloaded plant heating systems are returned to normal operation. 5. Water condensation problems are reduced or eliminated. 6. Low initial equipment cost (assuming boiler capacity is already available) on steam units. 7. No elaborate safety controls resulting in few nuisance shutdowns. 8. Simple control system and therefore electrical maintenance is simplified. 9. Minimal safety hazards. A Single Package Assembly Gas The Hartzell gas fired units produce very low levels of CO and are easy to maintain. Base unit consists of fan and burner sections. Many optonal features are available. Steam The Hartzell steam make-up air unit is a single package assembly. The standard unit includes fan, housing, steam coil, and shutter, pre-wired except for the steam valve. (Plumbing and valve wiring are supplied by the customer at the job site.) The standard control package provides for constant discharge air temperature, and low temperature shutdown to protect against coil freeze-up. 4

5 Installation Configurations Typical installation configurations are listed below. These are offered for your guidance and consideration. Accessories are also available to complete your packaged installation. Ductwork is not provided by Hartzell. Hartzell Direct Gas Fired Make-Up Air Heaters are designed for installation on crossbeams as standard. Optional perimeter curb mounting construction is available as an option. Limited vertical installation configurations for full size units are available. Please contact the factory. Air Recirculating Feature: Optional manual or automatic modulating air circulation is available on centrifugal models GFR and GMC. For sizes above 60,000 CFM contact factory.. Horizontal Unit Installed Inside The Building Series 86 Steam Type C or D PROPELLER CENTRIFUGAL 3,000 to 100,000 CFM 3,000 to 100,000 CFM Horizontal Unit Installed Outside The Building PROPELLER CENTRIFUGAL ECONO 78H 3,000 to 100,000 CFM 3,000 to 100,000 CFM 7,100 to 28,000 CFM PROPELLER CENTRIFUGAL GFR 3,000 to 100,000 CFM 3,000 to 100,000 CFM 2,000 to 60,000 CFM Vertical Installations 78V PROPELLER CENTRIFUGAL GFR 3,000 to 100,000 CFM 3,000 to 100,000 CFM 2,000 to 60,000 CFM VARIES WITH CONDITION PLEASE CONTACT FACTORY 5

6 Model GFR Forward Curved Centrifugal Gas Air Make-Up with Air Recirculation Features Construction Features Direct Gas Fired Forward Curved Make-Up Air Heaters, Model GFR, are rated for 2,000 CFM (200,000 BTU/Hr) through 60,000 CFM (9,788,850 BTU/Hr). Units sized 2,000 CFM through 30,000 CFM utilize a single, DWDI forward curve blower. Units 35,000 CFM through 60,000 CFM utilize twin, DWDI forward curve blowers. These units are best suited for applications through 2 1/2 external static pressure. Hartzell Model GFR units are completely packaged. Units are factory assembled and tested before shipment. Basic units 2,000 CFM through 30,000 CFM, will ship in 1 piece, while 35,000 CFM through 60,000 CFM units will ship in 2 pieces. These units are easy to install, easy to operate, lightweight, low in cost and low in maintenance. Model GFR Twin (Right Hand Controls Pictured) Standard Features Unit housings are constructed of 16-gauge G-90 galvanized steel. The basic unit consists of a fan and burner section, NEMA 4/12 control cabinet, plumbing, burner/recirculating air section and inlet bird screen. Both the electrical control cabinet and plumbing are mounted externally. Roofs are peaked to resist water penetration and collection. On sizes 15,000 CFM through 60,000 CFM, units have a standing seam roof. Standard mounting position for control cabinets and plumbing is on the right hand side of the unit. The access door will be opposite the control cabinet (left hand side). Standard right hand control position is determined by facing into the airstream. Left hand controls are optional. Lifting lugs are standard on all units. The air recirculation feature on Model GFR is designed to provide continuous building air make up, pressurization, and heating with maximum efficiency. These self-contained units are fully factory wired, plumbed, assembled and tested. They are designed to provide control of the make up air volume, via building pressure, or manually adjusted potentiometer located on the remote station. Units are direct fired, designed to burn either natural gas or propane with 20% to 100% fresh air intake and 0% to 80% recirculated air. This allows recirculation of clean plant air when heating, pressurization requirements and exhaust loads are at minimum levels. Motorized recirculation and profile plate dampers are standard. Remote stations with Fan, Off, and Heat selector switch and recirc control is standard. Fan motors mounted in the airstream as standard. Drives are fixed pitch type with belts that are oil, heat, and static resistant. Relubricable pillow block bearings are standard, with a minimum L10 life of 30,000 hours. Burners are Maxon Type NP-LE with a maximum 25:1 turn down ratio with natural gas or 20:1 turndown ratio with propane gas. The standard temperature control system is Maxitrol Series 14, which controls the discharge duct temperature. Standard units can develop a maximum discharge temperature of 90 F. 6 Control Panel (door removed) Type IRI Gas Plumbing Train Basic Operation and Controls Hartzell Model GFR Direct Gas Fired Forward Curved Make- Up Air Heaters with Air Recirculation Features are provided with a control system as standard. This system includes the master control panel mounted in a NEMA 4/12 enclosure. It consists of the motor starter, disconnect switch, control transformer, terminal strips, flame management system, burner modulation control and temperature controls. Standard control package includes state-of-the-art, commercially available components such as Maxitrol air temperature control system, and Fireye or Honeywell flame safeguard. Specific models may change depending on optional controls specified. Optional Controls Maxitrol Series 44 air temperature control system. Permits maximum control of space temperature Room override station Maxitrol 14 only Pre-purge timer Circuit Analyzer Lights Programmable timers Mild weather stat Clogged filter indicator Service light & receptacle Exhaust fan interlock English text readout Flame-Out indicator Smoke detector Access door interlock switch

7 Optional Features Motor operated center pivoted damper with channel frame and 16-gauge galvanized steel blades. Typical installation is at air discharge, or air entering end. Motor operator is interlocked with unit controls. Filter cabinet 16-gauge galvanized steel construction with reinforced self-forming flanges. This separate modular accessory contains a side access door for access to the filter frame, which has a double V arrangement. Disposable filters come standard with the filter box. Permanent filters available. Filter boxes for intake side of burner only. Intake weatherhood 16-gauge galvanized steel. Outdoor construction requires a plumbing cover over complete plumbing train. Discharge boot for attaching customer s ducting. 2- & 4-way discharge diffusers available. Perimeter curb mount accommodates weather and leakage protection when the unit is mounted on a full perimeter pre-fabricated roof curb. Pre-fabricated roof curb full perimeter mount with built-in wooden nailer strip that facilitates fastening the unit to the curb. Includes a rigid 1 1/2 thick 3 lb. density glass fiber liner that eliminates condensation problems. 1/4 neoprene sealer strip is standard. Construction is galvanized steel with fully welded seams. Optional Outlet Damper Adjustable Profile Blades Recirc Units Only Burner Optional Inlet Damper Outside Air Recirculated Air Adjustable Recirculating Dampers OFF Summer Winter Set selector to SUMMER for untempered air; to WINTER for heated air. Airflow switch does not permit burner to ignite if airflow is inadequate. High-temperature limit shuts unit off if discharge temperature rises over 140 F set point. Combination high-and-low gas pressure switch shuts off burner if pressure fluctuates excessively. Return Air Recirculating Unit Controls Manual Operation During down-time recirculating shutters are closed. Upon start-up, Recirc Shutter moves to whatever position the Return Air controller is set, up to 80% recirc air. The Shutter at the Burner moves conversely to the above Recirc Shutter, maintaining proper velocity across the burner. Flame Safeguard monitors normal startup. Closes main gas valve instantly upon flame failure. Automatic gas shut-off valve opens after all safety devices are satisfied and gas pilot is ignited and proved by flame safeguard. Automatic Operation Automatic modulation for face- and Recirc Dampers. Dampers are modulated based on internal building pressure. Set point can be adjusted on controller at remote station. If a pressure signal is supplied, a controller reads the signal and compares it to the controller setpoint. Discharge temperature controller maintains constant discharge air temperature. Modulating solenoid opens/closes gas valve as ordered by controller. The controller then provides an output signal to the damper actuators to modulate the return air and burner (outside air) dampers. This maintains proper airflow velocity across the burner. 7

8 Performance ON BTU/Hr External Static 90 1/4 1/ /2 2 21/2 Model Number CFM Temp Rise RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP _GFR3--21FC--2GLFC_3 2, , / / _GFR3--31FC--3GLFC_3 3, , _GFR3--41FC--4GLFC_3 4, , _GFR3--51FC--5GLFC_3 5, , _GFR3-101FC-10GLFC_3 10,000 1,000, _GFR3-151FC-15GLFC_3 15,000 1,500, _GFR3-201FC-20GLFC_3 20,000 2,000, _GFR3-251FC-25GLFC_3 25,000 2,500, _GFR3-301FC-30GLFC_3 30,000 3,000, _GFR3-352FC-35GLFC_3 35,000 3,500, _GFR3-402FC-40GLFC_3 40,000 4,000, _GFR3-452FC-45GLFC_3 45,000 4,500, _GFR3-502FC-50GLFC_3 50,000 5,000, _GFR3-552FC-55GLFC_3 55,000 5,500, _GFR3-602FC-60GLFC_3 60,000 6,000, NOTES: CFM shown is net flow at discharge, and includes internal static pressure loss for fan and burner sections. When applying inlet damper add 1/8 Ext. S.P. When applying washable filters, add 1/8 Ext. S.P. When applying disposable filters, add 1/4 Ext. S.P. BHP includes drive losses. Standard motor is ODP, mounted in airstream, with 1.15 service factor. Specify motor nameplate HP rating accordingly. Principal Dimensions FAN & BURNER HOUSE (SIDEBLAST DISCHARGE) A I R F L O W OFF S Model No. J S GFR GFR GFR15 36 GFR GFR25 GFR GFR35 GFR GFR45 GFR GFR55 GFR FILTER HOUSE ACCESS DOOR 30 1/8 SAFETY GUARD (WIRE MESH) STANDARD ITEM AT INTAKE OF UNIT. J 8

9 ON Principal Dimensions C D 30 1/8 12 J OFF ACCESS DOOR INLET WEATHERHOOD (OPTIONAL) L DISCHARGE OPENING A I R F L O W A I R F L O W K SAFETY GUARD (WIRE MESH) STANDARD ITEM AT INTAKE OF UNIT. 4 TYPICAL DISCHARGE OPENING L FAN HOUSE (DOWNBLAST DISCHARGE) 2 TYPICAL FAN HOUSE (HORIZONTAL DISCHARGE) E. F RECIRC OPENING FILTER HOUSE (OPTIONAL) INLET DAMPER BOOT (OPTIONAL) A M INSIDE HSG. O.D. DISCHARGE N 8 A M INSIDE HSG. O.D. DISCHARGE N 8 B INSIDE HSG. 17 MAX. 17 MAX. PLUMBING COVER PLUMBING COVER RECIRC OPENING G DISCHARGE END DOUBLE WIDTH BLOWER H G. RECIRC OPENING Model No. CFM Range Max. Motor Frame Housing I.D. A B C D E F G H J K L M N GFR5 2-5, T GFR10 10, T GFR15 15, T GFR20 20, T GFR25 25, T GFR30 30, T GFR35 35, T GFR40 40, T GFR45 45, T GFR50 50, T GFR55 55, T GFR60 60, T NOTE: Dimensions subject to change. Certified prints available. Units with recirculating features contact factory for dimensions. Model Number CFM Fan Burner Filter Inlet Hood (Lbs.) Quantity & Size Range Section (Lbs.) Section (Lbs.) Box (Lbs.) Horiz. Only Filters Req d _GFR3--21FC--2GLFC_ (4) 20 x 25 x 2 _GFR3-101FC-10GLFC_3 10,000 1, (6) 16 x 25 x 2 (3) 20 x 25 x 2 _GFR3-151FC-15GLFC_3 15,000 1,252 (12) 16 x 25 x _GFR3-201FC-20GLFC_3 20,000 1,643 (4) 20 x 25 x 2 _GFR3-251FC-25GLFC_3 25,000 1,804 _GFR3-301FC-30GLFC_3 30,000 2, (20) 20 x 25 x 2 _GFR3-352FC-35GLFC_3 35,000 1,186 1,198 (8) 16 x 25 x _GFR3-402FC-40GLFC_3 40,000 1,531 1,312 (16) 25 x 20 x 2 _GFR3-452FC-45GLFC_3 45,000 1,828 1,461 (15) 16 x 25 x _GFR3-502FC-50GLFC_3 50,000 1,828 1,481 (25) 20 x 25 x 2 _GFR3-552FC-55GLFC_3 55,000 2,273 1,497 _GFR3-602FC-60GLFC_3 60,000 2,273 1, (40) 20 x 25 x 2 9

10 Model GMP (Propeller Fan) Model GMC (Centrifugal Fan) Construction Features The Hartzell pre-engineered make-up air systems, when properly applied, eliminate hot and cold spots, supplying fresh clean air at the right temperature. Existing ventilation systems will work better, which accommodates more effective employees and production systems. Hartzell offers a broad range of axial and centrifugal models. These are modular units that can be configured to meet your requirements. Hartzell gas fired intake units are completely packaged, factory assembled and tested before shipment. These units are easy to install, easy to operate, low in cost and low in maintenance. GMC with Optional Filter Box Standard Features Axial (GMP) 3,000 through 100,000 CFM (300,000 through 10,000,000 BTU/HR) at 92 F temperature rise. 24 through 85 cast aluminum propeller fan. Ideal for low static pressure applications through 1/2 w.g. Centrifugal (GMC) 3,000 through 100,000 CFM (300,000 through 10,000,000 BTU/HR) at 92 F temperature rise. 15 through 54 DWDI (Double Width Double Inlet). Class I ideal for applications through 2 static pressure w.g. Unit 16 gauge galvannealed steel painted on the outside. The unit has internal self-formed flanges. Basic unit consists of fan section and burner section. All sections include formed steel mounting rails. Inlet bird screen is standard. Roofs are peaked to resist water penetration and collection. Controls and plumbing train are contained in a weatherproof enclosure outside the airstream. They are located on the right side of the unit (facing air discharge) as standard. Location on left side may be specified. Belt Drive All models have the fan motor in the airstream, belts are oil, heat and static resistant. Relubricable pillow block bearings are standard with a minimum L-10 life of 50,000 hours. Fixed drives are standard. Burner Maxon Series NP-LE burner with a maximum turn down ratio 25:1 with natural gas or 20:1 turndown ratio with propane gas. Maxitrol Series 14 air temperature control system. Controls discharge duct air temperature. Standard unit develops a maximum discharge temperature of 90 F. For optional discharge temperatures, contact factory. 10

11 Basic Operation and Controls All Hartzell Model GMP and GMC direct gas fired make-up air heaters are provided with a control system as standard. This system includes the master control panel mounted in a Nema 4/12 external control cabinet enclosure. It consists of the motor starter, or control transformer, terminal strips, airflow switch, flame management system, burner modulation control and temperature controls. Standard control package includes state-of-the-art, commercially available components such as Maxitrol air temperature control system, Honeywell Series 7800 flame safeguard system and electronic temperature and passive limit controls. Specific models may change depending on optional controls specified. A description of the Hartzell controls follows: Optional controls such as remote station, which is typically mounted at the floor level and consists of start and stop push buttons and fan/heat selector switch. Optional Remote Station Control Panel/Gas Plumbing Train Additional optional controls such as pre-purged timers, room temperature controllers and programmable timers are also available. English text readout Circuit analyzer lights Motor operated intake or discharge shutter Remote discharge air temp control Mild weather stat Clogged filter indicator Self-checking scanner Service light & receptacle Exhaust fan interlock Smoke sensors Recirculation feature Standard Unit Controls (Propeller or Centrifugal) OFF Summer Winter Set selector to SUMMER for untempered air; to WINTER for heated air. A description of the Hartzell optional recirculating unit controls, both manual and automatic follows: Airflow switch does not permit burner to ignite if airflow is inadequate. High-temperature limit shuts unit off if discharge temperature rises over 140 F set point. Combination high-and-low gas pressure switch shuts off burner if pressure fluctuates excessively. Flame Safeguard monitors normal start-up. Closes main gas valve instantly upon flame failure. Return Air Optional Recirculating Unit Controls Manual Operation Optional Face and Recirc Feature: During downtime, recirculating shutters are closed. Upon start-up, Recirc Shutter moves to whatever position the Return Air controller is set, up to 80% recirc air. The Shutter at the Burner moves conversely to the above Recirc Shutter. Automatic gas shut-off valve opens after all safety devices are satisfied and gas pilot is ignited and proved by flame safeguard. Discharge temperature controller maintains constant discharge air temperature. Automatic Operation Automatic modulation for face- and Recirc Dampers. Dampers are modulated based on internal building pressure. Set point can be adjusted on controller at remote station. If a pressure signal is supplied, a controller reads the signal and compares it to the controller setpoint. Modulating solenoid opens/closes gas valve as ordered by controller. The controller then provides an output signal to the damper actuators to modulate the return air and burner (outside air) dampers. This maintains proper airflow velocity across the burner. 11

12 Optional Features Maxitrol Series 44 air temperature control system. Permits maximum control of space temperature. Motor operated center-pivoted shutter with channel frame and 16 gauge steel blades. Typical installation is at air discharge end. Shutter motor operator is interlocked with unit controls. Filter cabinet 16 gauge galvannealed steel construction with reinforced self-forming flanges. This separate modular accessory contains a side access door for access to the filter frame, which has a double V arrangement. Disposable filters come standard with the filter box. Permanent filters available. Only inlet mounting available. Intake weatherhood 16 gauge galvannealed steel. Turning elbows turn the inlet or discharge airflow 90 with the aid of guide vanes. Centrifugal units discharge may be set for downblast vertical construction. Service platform constructed to comply with safety code (OSHA) for horizontal units. 2- & 4-way discharge diffusers available. Perimeter curb mount accommodates weather and leakage protection when the unit is mounted on a full perimeter prefabricated roof curb. Prefabricated roof curb full perimeter mount with built-in wooden nailer strip that facilitates fastening the unit to the curb. Includes a rigid 1 1 ¼2 thick 3-lb. density glass fiber liner, which eliminates condensation problems. 1/4 neoprene sealer strip is standard. Construction is galvanized steel with fully welded seams. Optional Recirculation Features (GMC model shown) Air recirculation feature available on both centrifugal (GMC) and propeller (GMP) models, is designed to provide continuous building air make-up, pressurization, and heating with maximum efficiency. These self-contained units are fully factory wired, plumbed, assembled and tested. They are designed to provide control of the make-up air volume, via pressure or manually adjusted potentiometer. Units are direct fired, designed to burn either natural gas or propane with 20% to 100% fresh air intake and 0% to 80% recirculated air. This allows recirculation of clean plant air when heating, pressurization requirements and exhaust loads are at minimum levels. 12

13 Performance Model GMP Performance (Propeller Fan) 0 S.P. 1/8 S.P. 1/4 S.P. 3/8 S.P. 1/2 S.P. Model Number CFM BTU/HR RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP _GMP---31-L--3GNFC_3 3, , _GMP---51-L--5GNFC_3 5, , _GMP---71-L--7GNFC_3 7, , _GMP--101-L-10GNFC_3 10,000 1,000, _GMP--121-L-12GNFC_3 12,500 1,250, _GMP--151-L-15GNFC_3 15,000 1,500, _GMP--201-L-20GNFC_3 20,000 2,000, _GMP--251-L-25GNFC_3 25,000 2,500, _GMP--301-L-30GNFC_3 30,000 3,000, _GMP--351AA-35GNFC_3 35,000 3,500, _GMP--401-L-40GNFC_3 40,000 4,000, _GMP--451-L-45GNFC_3 45,000 4,500, _GMP--501-L-50GNFC_3 50,000 5,000, _GMP--601AA-60GNFC_3 60,000 6,000, _GMP--751AA-75GNFC_3 75,000 7,500, _GMP--901AA-90GNFC_3 90,000 9,000, _GMP-1001AA100GNFC_3 100,000 10,000, Model GMC Performance (Centrifugal Fan) 1/2 S.P. 1 S.P. 1 1/2 S.P. 2 S.P. BC Wheel BA Wheel BC Wheel BA Wheel BC Wheel BA Wheel BC Wheel BA Wheel Model Number CFM BTU/HR RPM BHP RMP BHP RPM BHP RMP BHP RPM BHP RPM BHP RPM BHP RMP BHP _GMC3--31B_--3GNFC_3 3, , N/A N/A N/A N/A N/A N/A N/A N/A _GMC3--51B_--5GNFC_3 5, , N/A N/A N/A N/A N/A N/A N/A N/A _GMC3--71B_--7GNFC_3 7, , _GMC3-101B_-10GNFC_3 10,000 1,000, _GMC3-121B_-12GNFC_3 12,500 1,250, _GMC3-151B_-15GNFC_3 15,000 1,500, _GMC3-201B_-20GNFC_3 20,000 2,000, _GMC3-251B_-25GNFC_3 25,000 2,500, _GMC3-301B_-30GNFC_3 30,000 3,000, _GMC3-351B_-35GNFC_3 35,000 3,500, _GMC3-401B_-40GNFC_3 40,000 4,000, _GMC3-451B_-45GNFC_3 45,000 4,500, _GMC3-501B_-50GNFC_3 50,000 5,000, _GMC3-601B_-60GNFC_3 60,000 6,000, _GMC3-751B_-75GNFC_3 75,000 7,500, _GMC3-901B_-90GNFC_3 90,000 9,000, _GMC31001B_100GNFC_3 100,000 10,000, NOTES: CFM shown is net flow at discharge, and includes internal static pressure loss for fan and burner sections. When applying damper, add 1/8 Ext. S.P. When applying washable filters, add 1/8 Ext. S.P. When applying disposable filters, add 1/4 Ext. S.P. When applying evaporative cooling module, add 1/4 Ext. S.P. BHP does not include drive losses. Standard motor is ODP, mounted in airstream, with 1.15 service factor. Specify motor nameplate HP rating accordingly. 13

14 Principal Dimensions N TYP A INSIDE HSG. 10 L TYP GENERAL PLAN VIEW E SQ. C PITCH FAN I.D. J K SQ. DISCHARGE OPENING B INSIDE HSG. AIRFLOW BLOWER HOUSE BURNER HOUSE PLUMBING/ELECTRICAL FILTER HOUSE INLET WEATHER HOOD DISCHARGE END (OPTIONAL SHUTTER NOT SHOWN) 1/2 DIA. HOLD H REQ'D CURB MOUNT CONST. (OPTIONAL) Principal Dimensions (Inches) Model GMP Model CFM Fan Max Motor Housing I.D. No. Range Size Frame A B C D E G H J K T U _GMP3 3, T _GMP5 5, T ¼ ¾ ¾ _GMP7 7, T _GMP10 10, T ¼ ¾ _GMP12 12, T _GMP15 15, T 69¼ 53 8½ 4 40¼ ½ ¾ _GMP20 20, T _GMP25 25, T ¼ _GMP30 30, T _GMP35 35, T ¼ _GMP40 40, T _GMP45 45, T ½ 6 58¼ ½ 1¼ _GMP50 50, T _GMP60 60, T ½ 6 63¼ ½ 1¼ _GMP75 75, T 90 w /o Filt House 73 _GMP90 90, T w/ _GMP , T Filt House 86¼ ¼ NOTE: Dimensions subject to change. Certified prints available. Right-hand controls and access shown. For ANSI units and units with recirculating features contact factory for dimensions. 14

15 Principal Dimensions Sizes 3,000 60,000 CFM 1/8" CLEARANCE FOR INSULATION BETWEEN HOUSINGS. BOOT, SHUTTER & ACTUATOR MTR (OPTIONAL) SEE NOTE 8 12 S 60 1/8 30 1/8 12 G OFF OFF ON ACCESS DOOR INLET WEATHERHOOD (OPTIONAL) L DISCHARGE OPENING AIRFLOW ON FAN HEAT K SAFETY GUARD (WIRE MESH) STANDARD ITEM AT INTAKE OF UNIT. D INLET DAMPER BOOT (OPTIONAL) 2" CURB MOUNT CONST. (OPTIONAL) FAN HOUSE (HORIZONTAL DISCHARGE) T SIZE MALE N.P.T. FUEL GAS SUPPLY CONNECTION BURNER HOUSE ELECTRICAL SUPPLY FILTER HOUSE (OPTIONAL) U SIZE MALE N.P.T. GAS VENT LINE. CONNECTION (SUPPLIED ON IRI TYPE UNITS ONLY) CURB MOUNT CONST. (OPTIONAL) A M INSIDE HSG. OPENING N 10 F c PITCH B INSIDE HSG. A I R F L O W E C 1/2 DIA. HOLE H REQ.D. R DISCHARGE L OPENING FAN HOUSE (DOWNBLAST DISCHARGE) GENERAL PLAN VIEW DISCHARGE END (OPTIONAL SHUTTER NOT SHOWN) CURB MOUNT CONST. (OPTIONAL) AIRFLOW FAN HOUSE BURNER HOUSE FILTER HOUSE INLET WEATHER HOOD Principal Dimensions (Inches) Model GMC PLUMBING ELECTRICAL Model CFM Fan Max Motor Housing I.D. No. Range Size Frame A B C D E F G H K L M N R S T U _GMC3 3, T _GMC5 5, T ½ 4 23¾ ½ 16½ 22 3 / / / /8 ¾ ¾ _GMC7 7, T _GMC10 10, T ½ 4 30½ ½ 21 7 / ½ 20½ 60 1 /8 1 ¾ _GMC12 12, T _GMC15 15, T 69¼ 53 8½ / / / / / / / /8 1½ ¾ _GMC20 20, T _GMC25 25, T ½ /16 34¼ / / / / /8 2 1 _GMC30 30, T _GMC35 35, T /8 40¾ ½ 38 5 / /32 18½ 33¼ 90¼ 2 1 _GMC40 40, T _GMC45 45, T ½ 45½ ¼ 43 3 / / / /16 90¼ 2½ 1¼ _GMC50 50, T _GMC60 60, T / / ¾ 64 5 / / /8 90¼ 2½ 1¼ _GMC75 75, T _GMC90 90, T See Page 16 for Dimensional Data _GMC , T NOTE: Dimensions subject to change. Certified prints available. Right-hand controls and left hand fan and burner house access shown. For ANSI units and units with recirculating features contact factory for dimensions. 15

16 Principal Dimensions Sizes 75, ,000 CFM DAMPER AND BOOT (OPTIONAL) BLOWER HOUSE CENTRIFUGAL BLOWER (DWDI) TOP HORIZONTAL DISCHARGE FILTER HOUSE (OPTIONAL) BURNER HOUSE WEATHER HOOD (OPTIONAL) 58 1/4 AIRFLOW ACCESS DOOR CONTROL CABINET 46 7/ / /8 160 END VIEW DISCHARGE 55 5/8 REF. * GAS PIPING LOCATIONS 85 MAX. CFM Rating *Horizontal units with horizontal discharge 102" *Horizontal units with vertical discharge 110" Burner Data Standard Length Burner (Feet) Horizontal units with horizontal discharge 204 Horizontal units with vertical discharge 212 Output at Temp. Rise Inlet Gas Pressure Req d High Fire (1000 BTUH) at High Fire ( F) at High Fire MIN. STD. MAX. MIN. STD. MAX. MIN. (W.G.) MAX. 3, (W.G.) 5, / (W.G.) 7, (W.G.) 10, / psi 12, psi 15, / psi 20, / psi 25, / psi 30, psi 35, psi 40, psi 45, psi 50, psi 60, / psi 75, psi 90, psi 100, / psi 16

17 Vertical Installation Model GMC Model No. CFM Range D G S _GMC3 3,000 _GMC5 5, /8 _GMC7 7,000 _GMC10 10, /8 _GMC12 12,500 _GMC15 15, /4 _GMC20 20,000 _GMC25 25, /4 _GMC30 30,000 _GMC35 35, /8 _GMC40 40,000 _GMC45 45, /8 _GMC50 50,000 _GMC60 60, /8 _GMC75 75,000 _GMC90 90,000 CONTACT FACTORY _GMC ,000 Model GMP Model No. CFM Range D J B _GMP3 3,000 _GMP5 5, _GMP7 7,000 _GMP10 10, _GMP12 12,500 _GMP15 15, _GMP20 20,000 _GMP25 25, _GMP30 30,000 _GMP35 35, _GMP40 40,000 _GMP45 45, _GMP50 50,000 _GMP60 60, _GMP75 75,000 _GMP90 90, _GMP ,000 Principal dimensions are the same for vertical and horizontal units, see Pages 14 and 15. NOTE: Dimensions subject to change. Certified prints available. For units with recirculating features, contact factory for dimensions. 17

18 Installation Data Model GMP (Propeller Fan) Model No. Max. CFM Range Inlet Gas Pressure Range (Qty) & Size Filters Req d Fan Section Less Motor Disch. Boot, Shutter/Mtr. Burner Section Approx. Max. Weights Filter Section Inlet Guard Inlet Hood Turning Elbow _GMP3 3,000 7 W.G. to _GMP5 5, W.G. (6) 16 x 25 x _GMP7 _GMP10 7,000 10, W.G. to 5 lbs. W.G. _GMP12 12, W.G. to _GMP15 15,000 5 lbs. W.G. (6) 20 x 25 x 2 (3) 16 x 25 x 2 (3) 20 x 25 x 2 (9) 16 x 25 x _GMP20 _GMP25 20,000 25, W.G. to 5 lbs. W.G. _GMP30 30, W.G. to _GMP35 35,000 5 lbs. W.G. _GMP40 40,000 _GMP45 45, W.G. to 5 lbs. W.G. _GMP50 50,000 _GMP60 60,000 _GMP75 75,000 _GMP90 90,000 _GMP , W.G. to 5 lbs. W. G. (16) 20 x 25 x (10) 20 x 25 x 2 (15) 16 x 25 x 2 (24) 20 x 25 x 2 (6) 16 x 25 x (40) 20 x 25 x (60) 20 x 25 x with transition w/o filter house 700 w/filter house & trans Model GMC (Centrifugal Fan) Sizes 3, ,000 CFM Model No. Max. CFM Range Inlet Gas Pressure Range (Qty) & Size Filters Req d Fan Section Less Motor Disch. Boot, Shutter/Mtr. Approx. Max. Weights Burner Section Filter Section Inlet Guard Inlet Hood _GMC3 3,000 7 W.G. to _GMC5 5, W.G. (6) 16 x 25 x _GMC7 _GMC10 7,000 10, W.G. to 5 lbs. W.G. _GMC12 12, W.G. to _GMC15 15,000 5 lbs. W.G. (6) 20 x 25 x 2 (3) 16 x 25 x 2 (3) 20 x 25 x 2 (9) 16 x 25 x _GMC20 _GMC25 20,000 25, W.G. to 5 lbs. W.G. _GMC30 30, W.G. to _GMC35 35,000 5 lbs. W.G. _GMC40 40,000 _GMC45 45, W.G. to 5 lbs. W.G. _GMC50 50,000 _GMC60 60,000 _GMC75 75,000 _GMC90 90,000 _GMC , W.G. to 5 lbs. W. G. (16) 20 x 25 x (10) 20 x 25 x 2 (15) 16 x 25 x 2 (24) 20 x 25 x 2 (6) 16 x 25 x (40) 20 x 25 x (70) 20 x 25 x

19 Series 78H & 78V Econo Gas Heaters Horizontal and Vertical Units Econo models are a low cost alternative to many air make-up problems faced in industry today. Units are ideal for supplying tempered make-up air or for total fresh air heating systems. Each unit is a complete air supply system in a self-contained package consisting of a fan, burner and controls. The assembly is designed for indoor or outdoor installation and is ready for connection to gas line and power source. The Series 78H econo unit is designed for horizontal installations; excellent for perimeter type heating of troublesome areas. The Series 78V econo is engineered for vertical type installations. The equipment can supply filtered or unfiltered make-up air or be used for a total fresh air heating system. The unit has a low silhouette, and installation is quite simple. Series 78H Series 78V Features: 7,100 to 23,500 1/4 external static pressure. Heating capacities of 950,000 to 2,900,000 BTU/HR available. Intake ventilator hood on Series 78V is constructed of 18 gauge internally reinforced, painted, galvannealed steel. Base is 14 gauge painted galvannealed steel. Front burner section is 10 gauge. Controls are mounted and wired. Burner is designed for natural gas or propane. Direct drive fan arrangement, motor in airstream. Motors are totally enclosed. Propellers are cast aluminum, airfoil design, 6-bladed fixed pitch design through 19,200 CFM units; 6-bladed, adjustable pitch assemblies are standard on 21,750 CFM units and up. Controls are mounted in a NEMA 4/12 enclosure, containng the disconnect switch, motor starter, control transformer, fuses and terminal strips, gas pressure switches and temperature controls, IRI control package is standard. Also meets FM requirements. NEMA 12 Remote Station. Econo units are furnished with left-hand control cabinet as shown in photograph above. Maxitrol 14 is standard. Maxitrol modulating temperature control. Temperature sensing elements mounted in airstream. High and low temperature limit control mounted within burner housing. Standard unit develops a maximum discharge temperature of 90 F. For optional discharge temperatures, contact factory. Motor operated shutter. Access door for servicing is standard. Econo models are available with filters. Airflow proving switch. Fireye flame safeguard. Fused disconnect switch High and low temperature controls. Mild weather thermostat. High and low gas pressure limits. Built to meet I.R.I. or F.M. Standards 19

20 Dimensions and Performance Principal Dimensions (Inches) Series 78H Model Net Installation No. A B C D E F G H Wt.* 78H-28DI / / / / / H-44PJ / / / / H-48AL / / / / / / NOTE: Dimensions are subject to change. Certified prints are available. *Wt. less filter house Rating Table Series 78H Basic Unit Filtered Unit Gas Pressure 0 Ext. S.P. /4 Ext. S.P. 0 Ext. S.P. /4 Ext. S.P. Req d Turn Model Motor Fan Fan No. Temp Temp Temp Temp Down No. BTU/HR HP RPM Size Type Blades CFM* Rise CFM Rise CFM Rise CFM Rise Min. Max. Ratio 78H-28DI4 950, / D 6 8, F 7, F 7, F 7, F 14 (W.G.) 5 psi 8:1 78H-44PJ5 1,920, P 6 19, F 17, F 17, F 14, F 14 (W.G.) 5 psi 12:1 78H-48AL5 2,900, AA 6 28, F 23, F 26, F 22, F 14 (W.G.) 5 psi 7:1 *CFM shown is net flow at discharge and includes static pressure loss for burner and shutter. NOTE: Static pressure for calculated resistances external to the unit assembly. Principal Dimensions (Inches) Series 78V Nominal Net Model Hood Installation No. A B C D E F G H J K Size Wt.* 78V-28DI / / / / / /2 12 (12) 20 x 20 x (4) 10 x 20 x 2 78V-44PJ / / / / / (6) 16 x 20 x (8) 20 x 20 x 2 78V-48AL / / / / / 8 4 3/ NOTE: Dimensions are subject to change. Certified prints are available. *Wt. less filters (14) 10 x 20 x 2 (20) 20 x 20 x Rating Table Series 78V Basic Unit Filtered Unit Gas Pressure 0 Ext. S.P. /4 Ext. S.P. 0 Ext. S.P. /4 Ext. S.P. Req d Turn Model Motor Fan Fan No. Temp Temp Temp Temp Down No. BTU/HR HP RPM Size Type Blades CFM* Rise CFM Rise CFM Rise CFM Rise Min. Max. Ratio 78V-28DI4 950, / D 6 8, F 7, F 8, F 7, F 14 (W.G.) 5 psi 8:1 78V-44PJ5 1,920, P 6 18, F 15, F 18, F 14, F 14 (W.G.) 5 psi 12:1 78V-48AL5 2,900, AA 6 27, F 22, F 26, F 21, F 14 (W.G.) 5 psi 7:1 *CFM shown is net flow at discharge and includes static pressure loss for burner and shutter. NOTE: Static pressure for calculated resistances external to the unit assembly. 20

21 Series 79 Gas Fired Door Heater Heating has always been a problem in plants, warehouses, factories, etc., when overhead doors are frequently opened and closed. The rushing in of cold air when the doors are open chills personnel and lowers their working efficiency. Normal heating systems, such as unit heaters or duct systems, are not capable of handling this problem. Furthermore, an extra, sudden load is thrown on the heating system and as a result, heating costs rise substantially. This bothersome and costly problem can be solved by the Hartzell Automatic Door Heater which directs a blast of high velocity heated air toward the door opening. As a result of the turbulence created, the hot air mixes with the cold air, and the bite of the cold air is eliminated. The Hartzell unit works whenever the door is raised far enough to trip the switch. The fan starts, after a brief pre-purge time period, and safety function check, a high velocity stream of heated air is blasted into the cold entering air. Hartzell Automatic Door Heaters come equipped with Duct Axial propellers designed for high velocity at medium noise levels. These heaters can be mounted in either horizontal or vertical position or at any angle in between. Every Hartzell Automatic Door Heater is completely assembled and tested at the factory and is shipped ready for installation. Generally, the only installation requirement is connecting a unit to the electrical and fuel supply systems. Standard Features Electronic Flame Safeguard with LED Status Indicating Lights Magnetic Starter Control Transformer Ignition Transformer Sparktrode Interrupted Pilot Main Fuel Safety Valve High & Low Gas Pressure Switches* High Temperature Limit Switch Remote Station for Floor Mounting with Status Indicating Lights and Summer/Off/Winter Selector Switch Door Switch Air Flow Switch Inlet Guard 12 Ga. Hot Rolled Steel Housing Finish is Air-Dry Alkyd Enamel Applied over Phosphatized Steel Combination F.M. & I.R.I. Models Available through the HRS (Hartzell Rotating Stock) Program. * I.R.I. units only ** F.M. units only Hartzell Automatic Door Heaters are designed for heating open doorways only... they are not to be used for general-purpose plant heating. Built to meet I.R.I. or F.M. Standards 21

22 Design and Installation Options SELF FORMED FLANGE 3 3/4 (BC) 5/16 DIA HOLE TYP 3 PL EQUALLY SPACED AIRFLOW O.D. 15 I.D. I.D. 7 1/2 Principal Dimensions Size A B C D E F G H / / / / / / / / / / / / /2 NOTE: Specifications are subject to change. Certified prints are available. Rating Table Model Code No. Motor Fan Input Outlet Final Temp. Temp. Inlet Gas No. Size H.P. RPM CFM BTU Velocity 70 Ent. Air Rise Pressure 1 1 / , ,000 3, DH / , ,000 3, / , ,000 3, , ,000 3, DH , ,000 3, , ,000 3, NOTE: Based on Natural Gas Specific Gravity BTU per cu.ft. Shipping weights: DH22, 350 lbs.; DH 24, 400 lbs. 3 3/4 9/16 DIA HOLE TYP 4 PL /8 Automatic Door Heater Sizing Information Door No. of Input BTU Size Unit Units per Unit 12 x 12 DH , x 14 DH , x 16 DH , x 16 DH , x 18 DH , x 20 DH ,000 For door sizes not covered, determine size and number of units on basis of approximately 5500 BTU/sq. ft. of door opening. NOTE: For proper application of Hartzell Automatic Door Heaters, the maximum square foot opening should not exceed 360 sq. ft. Overhead Door Mounted at a 45 or 30 angle, the Hartzell Automatic Door Heater directs a flow of hot air to the floor area just inside the doorway. The door switch turns on the heater when the door is opened. Roll Top Door Alternate vertical mounting of the Hartzell Automatic Door Heater may also be used with roll top or straight lift doors, directing a flow of hot air to the floor just inside the door opening. NOTE: It is recommended the door switch be mounted 24 from floor level. 14' 14' 12' Do Door Switch 22

23 Series 811 Shaft Heater Series 811 Standard Features All Hartzell Direct Gas Fired Shaft Heaters are provided with a control system as standard. This system includes the master control panel mounted in a NEMA 4/12 enclosure. It consists of the motor starter, disconnect switch, control transformer, terminal strips, gas pressure switches, airflow switch, flame management system, burner modulation control and temperature controls. Standard control package includes state-of-the-art, commercially available components such as Maxitrol air temperature control system and Honeywell Series 7800 flame safeguard system. Specific models may change depending on optional controls specified. BTU Range 7,000 to 100,000 CFM...works up to 1/2 external static pressure. Performance Primary functions To temper incoming down-cast ventilating air for comfort purposes. To raise the temperature of same above the freezing point of water; here the purpose is to avoid freezing of ground water seepage which otherwise would freeze and tend to partially block the shaft opening, reducing airflow. Advantages of Hartzell shaft heaters Mine personnel can work in comfortable temperatures. Volume of ventilation is maintained at desired levels. Because of direct firing, 100% of the BTU content of the fuel is utilized. 12-gauge steel housing reinforced with self-forming ribs for rigidity and flanges. Welded construction. Burner is designed for natural gas or propane. Belt drive arrangement, motor out of the airstream, is standard on units through 50,000 CFM. Drive bearings have extended grease tubes for servicing. 60,000 to 100,000 CFM units are belted, motor in airstream. Belts are oil, heat and static resistant. Propellers are cast aluminum, single piece, airfoil type, 3-, 6-, and 8-bladed on units through 50,000 CFM. 60,000 through 100,000 CFM units utilize 4- and 6-bladed adjustable pitch assemblies. Motors are TEFC. Special motors are available upon request. Special skids can be furnished, if required. Special control packages are available. Model CFM* Ext. SP** BTU/Hr 92 F Temp Rise Fan Size Fan RPM BHP No of Blades G , , G72 1/ G ,000 1,000, G102 1/ G ,000 1,500, G152 1/ G ,000 2,000, G202 1/ G ,000 2,500, G252 1/ G ,000 3,000, G302 1/ G ,000 4,000, G402 1/ G ,000 5,000, G502 1/ G ,000 6,000, G602 1/ G ,000 7,500, G752 1/ G ,000 9,000, G902 1/ G ,000 10,000, G1002 1/ ACCESS DOOR AIRFLOW Principal Dimensions CONTROL CABINET Model A B F G G G G G G G G G G G G SQ. INSIDE SQ. 23

24 Series SFC Centrifugal Steam Heater Centrifugal steam air intake units are furnished with DWDI forward curve industrial blowers. The unit is a packaged design with controls mounted and wired. Features: 2,000 to 60,000 CFM works up to 2.5 external static pressure. Units sized 2,000 CFM through 30,000 CFM utilizes a DWDI single forward curve blower. Units sized 35,000 CFM through 60,000 CFM utilizes a DWDI twin forward curve blower. 16-gauge G-90 galvanized steel housing. Horizontal mount unit standard. Controls are mounted and wired in a NEMA 4/12 cabinet, containing disconnect switch, motor starter, control transformer, fuses and terminal strips, connections to the modulating steam valve and optional room thermostat are made at time of installation. NEMA 12 standard remote station shipped loose. Modulating temperature control. Temperature sensing element mounted in the airstream. Low temperature limit control mounted within coil housing. Motor operated inlet damper. Access door for servicing is standard. Easy coil removal, slides in and out of unit on rails. Belt drive arrangement, belts are oil, heat, and static resistant. Motors are totally enclosed fan cooled; other motors are available. Accessories such as filter boxes and inlet weather hoods are the same sizes as the Gas Forward Curve Unit Disconnect switch standard. Model SFC Single Performance Model Number CFM 80 Temp Rise External Static Pressure RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP ASFC3--21FC--2GLFC_3 2, , ASFC3--31FC--3GLFC_3 3, , ASFC3--41FC--4GLFC_3 4, , ASFC3--51FC--5GLFC_3 5, , ASFC3-101FC-10GLFC_3 10, , ASFC3-151FC-15GLFC_3 15,000 1,305, ASFC3-201FC-20GLFC_3 20,000 1,740, ASFC3-251FC-25GLFC_3 25,000 2,175, ASFC3-301FC-30GLFC_3 30,000 2,610, ASFC3-352FC-35GLFC_3 35,000 3,045, ASFC3-402FC-40GLFC_3 40,000 3,480, ASFC3-452FC-45GLFC_3 45,000 3,915, ASFC3-502FC-50GLFC_3 50,000 4,350, ASFC3-552FC-55GLFC_3 55,000 4,785, ASFC3-602FC-60GLFC_3 60,000 5,220, Notes: BTUH is based on 20 PSIG steam pressure and 80 temperature rise, contact factory for your exact requirements. CFM shown is net flow at discharge and includes internal static pressure loss for fan and coil section. When applying washable filters, add 1/8 Ext. SP When applying disposable filters, add 1/4 Ext. SP. BHP includes drive loses. Standard motor is TEFC, mounted in the airstream, with 1.15 service factor, specify motor HP rating accordingly. 24

25 Principal Dimensions INSIDE HOUSING O.D. DISCHARGE 8 DISCHARGE ANGLE 30 1/8 12 FILTER HOUSE (OPTIONAL) HOOD (OPTIONAL) SLIP FIT DISCHARGE ANGLE AIRFLOW AIRFLOW INSIDE HOUSING O.D. DISCHARGE ANGLE CONTROL CABINET INLET DAMPER HOUSE (OPTIONAL) INSIDE HOUSING O.D. DISCHARGE 8 DISCHARGE ANGLE 30 1/8 FILTER HOUSE (OPTIONAL) 12 HOOD (OPTIONAL) SLIP FIT DISCHARGE ANGLE AIRFLOW AIRFLOW INSIDE HOUSING O.D. DISCHARGE ANGLE CONTROL CABINET INLET DAMPER HOUSE (OPTIONAL) CFM Max. Housing ID Model Number C D J K L M N P R Range Motor Frame A B ASFC3--51FC--5GLFC_3 2 to 5, T ASFC3-101FC-10GLFC_3 10, T ASFC3-151FC-15GLFC_3 15, T ASFC3-201FC-20GLFC_3 20, T ASFC3-251FC-25GLFC_3 25, T ASFC3-301FC-30GLFC_3 30, T ASFC3-352FC-35GLFC_3 35, T ASFC3-402FC-40GLFC_3 40, T ASFC3-452FC-45GLFC_3 45, T ASFC3-502FC-45GLFC_3 50,000 ASFC3-552FC-55GLFC_3 55, T ASFC3-602FC-60GLFC_3 60, T CFM Fan Heating Filter Inlet Quantity & Size Model Number Range Section (Lbs.) Section (Lbs.) Box (Lbs.) Hood (Lbs.) Filters Req d ASFC3--51FC--5GLFC_3 2-5, (4) 20 x 25 x 2 ASFC3-101FC-10GLFC_3 10,000 1, (6) 16 x 25 x 2 (3) 20 x 25 x 2 ASFC3-151FC-15GLFC_3 15,000 1,252 (12) 16 x 25 x ASFC3-201FC-20GLFC_3 20,000 1,643 (4) 20 x 25 x 2 ASFC3-251FC-25GLFC_3 25,000 1,804 ASFC3-301FC-30GLFC_3 30,000 2, (20) 20 x 25 x 2 ASFC3-352FC-35GLFC_3 35,000 1,186 1,198 (8) 16 x 25 x ASFC3-402FC-40GLFC_3 40,000 1,531 1,312 (16) 25 x 20 x 2 ASFC3-452FC-45GLFC_3 45,000 1,828 1,461 (15) 16 x 25 x ASFC3-502FC-50GLFC_3 50,000 1,828 1,481 (25) 20 x 25 x2 ASFC3-552FC-55GLFC_3 55,000 2,273 1,497 ASFC3-602FC-60GLFC_3 60,000 2,273 1, (40) 20 x 25 x 2 25

26 Series SMP Propeller Steam Unit Type A (shown) Types A and B (Horizontal Intake Unit) Hartzell propeller steam air make-up units are designed around the proven 3-bladed, lo-noise airfoil propeller, providing full efficiency at slow speeds without excessive noise. 50,000-60,000 CFM units utilize an adjustable pitch, 6-bladed airfoil design assembly with belted construction, totally enclosed motor in airstream. The unit is a packaged design with controls mounted and wired. Features: 6,000 to 60,000 CFM...works up to 1/4 external static pressure. 12-gauge steel housing reinforced with self-forming ribs for rigidity and flanges. Welded construction. Controls are mounted and wired. Easy coil removal...slide in and out of the unit on rails. Belt drive arrangement, motor out of airstream. Drive bearings have extended grease tubes for servicing. Belts are oil, heat and static resistant. Motors are open end, protected. Totally enclosed fan cooled and other special motors are available. Belt guards are standard. NEMA 12 remote control station with pilot lights. Controls are mounted in a NEMA 4/12 panel and enclosure, containing the motor starter, control transformer, fuses, and terminal strips. (Connections to the modulating steam valve and optional room thermostat are made at the time of installation). Modulating temperature control. Temperature sensing element mounted in airstream. Low temperature limit control mounted within coil housing. Motor operated inlet damper. Access door for servicing is standard. Filter box on Type B unit can be located on discharge or intake side. Coils are non-freeze type protected by a low temperature thermostat. Accessories see Pages 38 and 39. Types C and D (Vertical Intake Unit) The Hartzell steam air make-up units, roof intake design, combine a hooded ventilator for fresh air intake with a steam heating system. The result is heated air make-up capability where vertical installation is required. The roof intake hood utilizes the proven lo-noise, 3-bladed cast aluminum propeller in a hood, providing complete protection from the elements. The heating section hangs beneath the roofline. Features: 6,000 to 45,000 CFM...works up to 1/4 external static pressure. Roof hood is constructed of 20-gauge galvanized steel. Heating section constructed of 12-gauge steel, housing is reinforced with self-forming ribs for rigidity and flanges. Welded construction. Controls are mounted and wired. Easy coil removal...slide in and out of the unit on rails. Belted arrangement, motor in the airstream. Drive bearings have extended grease tubes for servicing. Belts are oil, heat and static resistant. Motors are totally enclosed. Special motors are available upon request. NEMA 12 remote control station with pilot light. Controls are mounted in a NEMA 4/12 panel and enclosure containing the motor starter, control transformer, fuses, and terminal strips. Wiring to the fan motor must be done at installation. (Connections to the modulating steam valve and optional room thermostat are made at the time of installation). Fused disconnect switch standard. Modulating temperature control. Temperature sensing element mounted in airstream. Low temperature limit control mounted within coil housing. Motor operated inlet damper. Access door for servicing is standard. Filter box on Type C & D units can be located on discharge or intake side. Coils are non-freeze type protected by a low temperature ther mostat. Accessories see Pages 38 and (800)

27 Principal Dimensions Type A and B UNIT FAN SHAFT MODEL SIZE (CFM) HOUSING SIZE AT HUB AT BEARING A B C D E F SMP6 6,000 12GA / / / SMP8 8,000 12GA / / / / / SMP10 10,000 12GA / / / / / /2 42 SMP13 12,500 12GA / / / / / SMP15 15,000 12GA / / / / / /2 42 SMP20 20,000 12GA / / / / / SMP25 25,000 12GA / / / / / /2 42 SMP30 30,000 12GA / / / / / /2 42 SMP35 35,000 12GA / / / / / /2 42 SMP40 40,000 12GA / / / / / /2 42 SMP45 45,000 12GA / / / / / /2 42 SMP50 50,000 12GA / / / /2 42 SMP60 60,000 12GA / / / /2 42 Note: Specifications are subject to change. Certified prints are available. Type A Basic unit less filters Type B Basic unit with filters Type C and D UNIT HOOD SIZE FAN SHAFT NOM. MODEL (CFM) HOUSING SIZE AT HUB AT BEARING A B C D E F G H SIZE SMP6 6,000 12GA / / / /4 30 SMP8 8,000 12GA / / / / / /4 30 SMP10 10,000 12GA / / / / / / /4 30 SMP13 12,500 12GA / / / / / /4 36 SMP15 15,000 12GA / / / / / / /4 36 SMP20 20,000 12GA / / / / / /4 48 SMP25 25,000 12GA / / / / / / /4 48 SMP30 30,000 12GA / / / / / / /4 48 SMP35 35,000 12GA / / / / / / /4 54 SMP40 40,000 12GA / / / / / / / /4 60 SMP45 45,000 12GA / / / / / / / /4 60 Note: Specifications are subject to change. Certified prints are available. Type C Basic unit and roof hood less filters Type D Basic unit and roof hood less filters 27

28 Rating Tables Type A UNIT SIZE EXT. 5 PSIG 0 F EAT FAN FAN MTR. (CFM*) SP** BTU/HR RISE SIZE RPM HP 6, , ,000 1/4 536, /2 8, , /2 8,000 1/4 741, , , ,000 1/4 828, , ,199, ,500 1/4 1,199, , ,324, ,000 1/4 1,324, , ,071, ,000 1/4 2,071, , ,398, ,000 1/4 2,398, , ,616, /2 30,000 1/4 2,616, , ,433, /2 35,000 1/4 3,433, , ,749, /2 40,000 1/4 3,749, , ,973, /2 45,000 1/4 3,973, , ,905, /2 50,000 1 /4 4,905, , ,362, ,000 1/4 5,362, * CFM shown is net flow at discharge and includes static pressure loss for coil and shutter. ** Static pressure for calculated resistances external to the unit assembly Series SMP 50,000 and 60,000 CFM units; 20 psi minimum steam main pressure.. Type C UNIT SIZE EXT. 5 PSIG 0 F EAT FAN FAN MTR. (CFM*) SP** BTU/HR RISE SIZE RPM HP 6, , ,000 1/4 536, , , /2 8,000 1/4 741, , , ,000 1/4 828, , ,199, ,500 1/4 1,199, , ,324, ,000 1/4 1,324, , ,071, ,000 1/4 2,071, , ,398, ,000 1/4 2,398, /2 30, ,616, ,000 1/4 2,616, , ,433, /2 35,000 1/4 3,433, , ,749, ,000 1/4 3,749, , ,973, ,000 1/4 3,973, * CFM shown is net flow at discharge and includes static pressure loss for roof hood, coil, and shutter. ** Static pressure for calculated resistances external to the unit assembly. Series SMP 50,000 and 60,000 CFM units; 20 psi minimum steam main pressure Type B UNIT SIZE EXT. 5 PSIG 0 F EAT FAN FAN MTR. (CFM*) SP** BTU/HR RISE SIZE RPM HP 6, , /2 6,000 1/4 536, , , /2 8,000 1/4 741, , , ,000 1/4 828, , ,199, ,500 1/4 1,199, , ,324, ,000 1/4 1,324, , ,071, ,000 1/4 2,071, , ,398, ,000 1/4 2,398, /2 30, ,616, /2 30,000 1/4 2,616, , ,433, /2 35,000 1/4 3,433, , ,749, /2 40,000 1/4 3,749, , ,973, ,000 1/4 3,973, , ,905, /2 1 50,000 1/4 4,905, , ,362, ,000 1/4 5,362, * CFM shown is net flow at discharge and includes static pressure loss for coil, shutter and filter house. ** Static pressure for calculated resistances external to the unit assembly. Series SMP 50,000 and 60,000 CFM units; 20 psi minimum steam main pressure. Type D UNIT SIZE EXT. 5 PSIG 0 F EAT FAN FAN MTR. (CFM*) SP** BTU/HR RISE SIZE RPM HP 6, , /2 6,000 1/4 536, , , /2 8,000 1/4 741, , , ,000 1/4 828, , ,199, ,500 1/4 1,199, , ,324, ,000 1/4 1,324, /2 20, ,071, ,000 1/4 2,071, , ,398, ,000 1/4 2,398, /2 30, ,616, ,000 1/4 2,616, , ,433, /2 35,000 1/4 3,433, , ,749, ,000 1/4 3,749, , ,973, ,000 1/4 3,973, * CFM shown is net flow at discharge and includes static pressure loss for roof hood, coil, shutter and filter house. ** Static pressure for calculated resistances external to the unit assembly. Series SMP 50,000 and 60,000 CFM units; 20 psi minimum steam main pressure. 28

29 Coil and Filter Data UNIT SIZE COILS FILTERS (CFM) No. Total Face Area Number & Size Total Face Area 6, SQ. FT. (6) 25 x 16 x SQ. FT. 8, SQ. FT. (6) 25 x 20 x SQ. FT. 10, SQ. FT. (6) 25 x 20 x SQ. FT. 12, SQ. FT. (10) 25 x 20 x SQ. FT. 15, SQ. FT. (10) 25 x 20 x SQ. FT. 20, SQ. FT. (14) 25 x 20 x 2 + (7) 20 x 20 x SQ. FT. 25, SQ. FT. (14) 25 x 20 x 2 + (7) 20 x 20 x SQ. FT. 30, SQ. FT. (14) 25 x 20 x 2 + (7) 20 x 20 x SQ. FT. 35, SQ. FT. (27) 20 x 20 x 2 + (9) 25 x 20 x SQ. FT. 40, SQ. FT. (27) 20 x 20 x 2 + (9) 25 x 20 x SQ. FT. 45, SQ. FT. (27) 20 x 20 x 2 + (9) 25 x 20 x SQ. FT. 50, SQ. FT. (54) 25 x 16 x SQ. FT. 60, SQ. FT. (54) 25 x 16 x SQ. FT. Installation Weights For Types A & B Only For Types A, B, C & D Type D Diffusers UNIT Type A Type B Type C Roof-Hood Turning Weather SIZE (CFM) Basic Unit W/Filters Roof Hood W/Filters Elbow Hood 2-Way 4-Way 6, , , , , , , , , , , , , Notes: Weights are in lbs. for all units and include the following: TYPE A Basic unit only. TYPE B Basic unit and filter house. TYPE C Basic unit and roof hood. TYPE D Basic unit, roof hood and filter house. 29

30 Series SMC Centrifugal Steam Unit Types A and B (Horizontal Intake Unit) Centrifugal steam air intake units are furnished with DWDI fans with heavy-duty industrial forward-curved wheels. The result is efficient performance for industrial duct distribution systems where high static pressure capabilities are required. The unit is a packaged design with the controls mounted and wired. Features: 8,000 to 45,000 CFM...works up to external static pressure. 12-gauge steel housing reinforced with self-forming ribs for rigidity and flanges. Welded construction. Horizontal discharge is standard. Can be placed in vertical up or down position if specified. Controls are mounted and wired. Easy coil removal...slide in and out of the unit on rails. Belt drive arrangement, motor out of airstream. Drive bearings have extended grease tubes for servicing. Belts are oil, heat and static resistant. Motors are open end, protected. Totally enclosed fan cooled and other special motors are available. Belt guards are standard. NEMA 12 remote control station with pilot lights. Controls are mounted in a NEMA 4/12 panel end enclosure, containing the motor starter, control transformer, fuses and terminal strips. Wiring to the fan motor must be done at installation. (Connections to the modulating steam valve and optional room thermostat are made at the time of installation). Principal Dimensions (Type A and B) Note: Specifications are subject to change. Certified prints are available. Type A Basic unit less filters Type B Basic unit with filters Type A shown Fused disconnect switch standard. Modulating temperature control. Temperature sensing element mounted in airstream. Low temperature limit control mounted within coil housing. Motor operated inlet damper. Access door for servicing is standard. Coils are non-freeze type protected by a low temperature thermostat. Accessories see Pages 38 and 39. UNIT SIZE DWDI WHLS. GAUGES SHAFT MODEL (CFM) HOUSING HSGS WHLS AT HUB AT BEARING A B C D E F H J K L SMC8 8,000 12GA. 16GA. 18GA / / / / SMC10 10,000 12GA. 16GA. 18GA / / / / /2 SMC13 12,500 12GA. 16GA. 16GA / / / / / /2 SMC15 15,000 12GA. 16GA. 18GA / / / /2 SMC20 20,000 12GA. 16GA. 18GA / /2 SMC25 25,000 12GA. 16GA. 16GA / / / /2 SMC30 30,000 12GA. 16GA. 16GA / / / /2 SMC35 35,000 12GA. 16GA. 16GA. 4 1 / / / /2 SMC40 40,000 12GA. 16GA. 16GA. 4 1 / / / /2 SMC45 45,000 12GA. 16GA. 16GA. 4 1 / / / /2 Note: Top horizontal discharge standard. If bottom discharge required, specify. 30

31 Rating Tables Type A - less filters UNIT SIZE (CFM*) OUTLET VELOCITY 5 PSIG - 0 F EAT WHEEL NO. 0 EXT. SP** 1 2 EXT. SP** 1 EXT. SP** EXT. SP** BTU/HR RISE DIA. WHEELS RPM HP RPM HP RPM HP RPM HP 8, , , , , ,212, , ,340, , ,136, , ,452, , ,681, , ,357, , ,575, , ,825, **CFM shown is net flow at discharge and includes static pressure loss for coil and shutter. **Static pressure for calculated resistances external to the unit assembly. Type B - with filters UNIT SIZE OUTLET 5 PSIG - 0 F EAT WHEEL NO. 0 EXT. SP** 1 2 EXT. SP** 1 EXT. SP** EXT. SP** (CFM*) VELOCITY BTU/HR RISE DIA. WHEELS RPM HP RPM HP RPM HP RPM HP 8, , , , , ,212, , ,340, , ,136, , ,452, , ,681, , ,357, , ,575, , ,825, **CFM shown is net flow at discharge and includes static pressure loss for coil and shutter. **Static pressure for calculated resistances external to the unit assembly. Series SMC 25,000 CFM unit only; 15 psi minimum steam main pressure. Series SMC 30,000 thru 45,000 CFM units only: 20 psi minimum steam main pressure. Coil and Filter Data - Installation Weights UNIT SIZE COILS FILTERS (CFM) No. Total Face Area Number & Size Total Face Area 8, SQ. FT. (8) 25 x 20 x SQ. FT. 10, SQ. FT. (8) 25 x 20 x SQ. FT. 12, SQ. FT. (12) 25 x 20 x SQ. FT. 15, SQ. FT. (12) 25 x 20 x SQ. FT. 20, SQ. FT. (20) 25 x 20 x SQ. FT. 25, SQ. FT. (20) 25 x 20 x SQ. FT. 30, SQ. FT. (20) 25 x 20 x SQ. FT. 35, SQ. FT. (35) 25 x 20 x SQ. FT. 40, SQ. FT. (35) 25 x 20 x SQ. FT. 45, SQ. FT. (35) 25 x 20 x SQ. FT. UNIT Type A Type B SIZE Fan Basic Basic Units Weather (CFM) Size Units W/Filters Hood 8, , , , , , , , / , / , / Notes: Weights are in lbs. for all units and include the following: TYPE A Basic unit only. TYPE B Basic unit and filter house. 31

32 Series SAH and Series SCH Face and Bypass Assembly Series SAH Horizontal Axial Flow (shown) Series SCH Horizontal Centrifugal Face and bypass units provide better temperature modulation in marginal, as well as, extended cold weather by varying the airflow through the coil by means of proportioned face and bypass dampers. The damper enclosure is designed with a plenum chamber containing guide vanes providing for proper mixing of air. The result is modulating temperature control with full steam pressure at all times reducing the problem of coil freeze-up. The face and bypass section is available in two designs utilizing a Hartzell duct axial fan (Series SAH) or a DWDI forward curve centrifugal fan (Series SCH). Both are designed as packaged units with controls mounted and wired. Features: Series SAH Axial Units 8,000 to 45,000 CFM...works up to 1 external static pressure. Utilizes the Hartzell 6-bladed duct axial fan. Vane section available for higher static pressures up to 3 external. Series SCH Centrifugal Units 8,000 to 45,000 CFM...works up to external static pressure. Utilizes a DWDI heavy-duty industrial forward curve wheel. General Features: 12-gauge steel housing reinforced with self-forming ribs for rigidity and flanges. Welded construction. Horizontal discharge is standard. Can be built for vertical up or down position. Easy coil removal...slide in and out of the unit on rails. Belt drive arrangement, motor out of the airstream. Drive bearings have extended grease tubes for servicing. Belts are oil, heat and static resistant. Belt guards are standard. NEMA 12 remote control station with pilot lights. Controls are mounted in a NEMA 4/12 panel and enclosure containing the motor starter, control transformer, fuses, and terminal strips. Wiring to the fan motor must be done at installation. (Connections to the steam valve and optional room thermostat are made at the time of installation). Modulating temperature control. Temperature sensing element mounted in the airstream. Low temperature limit control mounted within coil housing. Unit can be used in both indoor and outdoor installations. Steam and return lines should be insulated in a common housing to prevent freezing in outdoor installations. Motor operated dampers. Access door for servicing is standard. Filter Box optional. Specify Type A (less filters) or Type B (with filters). Can be located on inlet only. Accessories see Pages 38 and

33 Principal Dimensions Series SAH UNIT SIZE FAN SHAFT MODEL (CFM) HOUSING SIZE AT HUB AT BEARING A B C D E F H J K L M N T SAH8 8, GA / / / / / / / / /4 2 SAH10 10, GA / / / / / / / / /4 2 SAH13 12, GA / / / / / / / /4 2 SAH15 15, GA / / / / / / / /4 2 SAH20 20, GA / / / / / SAH25 25, GA / / / / / / SAH30 30, GA / / / / / / SAH35 35, GA / / / / / / SAH40 40, GA / / / / / / SAH45 45, GA / / / / / / Note: Specifications are subject to change. Certified prints are available. Series SCH UNIT SIZE DWDI WHLS GAUGES SHAFT MODEL (CFM) HOUSING NO. SIZE HSGS WHLS AT HUB AT BRG A B C D E F G H J K L R T SCH8 8, GA / / / / / / /4 SCH10 10, GA / / / / / / /4 SCH13 12, GA / / / / / / SCH15 15, GA / / / / / /4 SCH20 20, GA / / / /4 SCH25 25, GA / / / / / SCH30 30, GA / / / / / SCH35 35, GA / / / / / / /2 SCH40 40, GA / / / / / / /2 SCH45 45, GA / / / / / / /2 Note: Specifications are subject to change. Certified prints are available. 33

34 Rating Tables - Series SAH (Axial Flow) Type A (less filters) UNIT SIZE EXT. 5 PSIG 0 F EAT FAN FAN MTR. (CFM*) SP** BTU/HR RISE SIZE RPM HP 8, , /2 8,000 1/4 741, ,000 1/2 741, , , , , ,000 1/4 828, ,000 1/2 828, , , /2 12, ,199, ,500 1/4 1,199, ,500 1/2 1,199, , ,199, , ,324, ,000 1/4 1,324, ,000 1/2 1,324, , ,324, /2 20, ,071, ,000 1/4 2,071, ,000 1/2 2,071, , ,071, /2 25, ,398, ,000 1/4 2,398, ,000 1/2 2,398, /2 25, ,398, , ,616, /2 30,000 1/4 2,616, ,000 1/2 2,616, , ,616, , ,433, ,000 1/4 3,433, ,000 1/2 3,433, , ,433, , ,749, ,000 1/4 3,749, ,000 1/2 3,749, , ,749, , ,973, ,000 1/4 3,973, ,000 1/2 3,973, , ,973, * CFM shown is net flow at discharge and includes static pressure loss for coil and shutter. ** Static pressure for calculated resistances external to the unit assembly. Type B (with filters) UNIT SIZE EXT. 5 PSIG 0 F EAT FAN FAN MTR. (CFM*) SP** BTU/HR RISE SIZE RPM HP 8, , /2 8,000 1/4 741, ,000 1/2 741, , , , , ,000 1/4 828, ,000 1/2 828, , , /2 12, ,199, ,500 1/4 1,199, ,500 1/2 1,199, , ,199, /2 15, ,324, ,000 1/4 1,324, ,000 1/2 1,324, , ,324, /2 20, ,071, ,000 1/4 2,071, ,000 1/2 2,071, , ,071, /2 25, ,398, ,000 1/4 2,398, ,000 1/2 2,398, /2 25, ,398, , ,616, /2 30,000 1/4 2,616, ,000 1/2 2,616, , ,616, , ,433, ,000 1/4 3,433, ,000 1/2 3,433, , ,433, , ,749, ,000 1/4 3,749, ,000 1/2 3,749, , ,749, , ,973, ,000 1/4 3,973, ,000 1/2 3,973, , ,973, * CFM shown is net flow at discharge and includes static pressure loss for coil, shutter and filter house. ** Static pressure for calculated resistances external to the unit assembly. Coil and Filter Data - Installation Weights UNIT SIZE COILS FILTERS (CFM) No. Total Face Area Number & Size Total Face Area 8, SQ. FT. (8) 25 x 20 x SQ. FT. 10, SQ. FT. (8) 25 x 20 x SQ. FT. 12, SQ. FT. (12) 25 x 20 x SQ. FT. 15, SQ. FT. (12) 25 x 20 x SQ. FT. 20, SQ. FT. (20) 25 x 20 x SQ. FT. 25, SQ. FT. (20) 25 x 20 x SQ. FT. 30, SQ. FT. (20) 25 x 20 x SQ. FT. 35, SQ. FT. (35) 25 x 20 x SQ. FT. 40, SQ. FT. (35) 25 x 20 x SQ. FT. 45, SQ. FT. (35) 25 x 20 x SQ. FT. UNIT FAN BASIC UNIT TYPE B TURNING WEATHER SIZE (CFM) SIZE TYPE A W/FILTERS ELBOW HOOD 8, , , , , , , , , ,

35 Rating Tables - Series SCH (Centrifugal) Type A (Centrifugal - less filters) UNIT SIZE (CFM*) OUTLET VELOCITY 5 PSIG - 0 F EAT WHEEL NO. 0 EXT. SP** 1 2 EXT. SP** 1 EXT. SP** EXT. SP** BTU/HR RISE DIA. WHEELS RPM HP RPM HP RPM HP RPM HP 8, , , , , ,212, , ,340, , ,136, , ,452, , ,681, , ,357, , ,575, , ,825, **CFM shown is net flow at discharge and includes static pressure loss for coil and shutter. **Static pressure for calculated resistances external to the unit assembly. Type B (Centrifugal - with filters) UNIT SIZE OUTLET 5 PSIG - 0 F EAT WHEEL NO. 0 EXT. SP** 1 2 EXT. SP** 1 EXT. SP** EXT. SP** (CFM*) VELOCITY BTU/HR RISE DIA. WHEELS RPM HP RPM HP RPM HP RPM HP 8, , , , , ,212, , ,340, , ,136, , ,452, , ,681, , ,357, , ,575, , ,825, **CFM shown is net flow at discharge and includes static pressure loss for coil and shutter. **Static pressure for calculated resistances external to the unit assembly. Coil and Filter Data - Installation Weights UNIT SIZE COILS FILTERS (CFM) No. Total Face Area Number & Size Total Face Area 8, SQ. FT. (8) 25 x 20 x SQ. FT. 10, SQ. FT. (8) 25 x 20 x SQ. FT. 12, SQ. FT. (12) 25 x 20 x SQ. FT. 15, SQ. FT. (12) 25 x 20 x SQ. FT. 20, SQ. FT. (20) 25 x 20 x SQ. FT. 25, SQ. FT. (20) 25 x 20 x SQ. FT. 30, SQ. FT. (20) 25 x 20 x SQ. FT. 35, SQ. FT. (35) 25 x 20 x SQ. FT. 40, SQ. FT. (35) 25 x 20 x SQ. FT. 45, SQ. FT. (35) 25 x 20 x SQ. FT. UNIT FAN TYPE A TYPE B WEATHER SIZE (CFM) SIZE BASIC UNIT W/FILTERS HOOD 8, , , , , , , , / , / , /

36 Series 77 Steam Unit Heaters Series 77 Steam Unit (1-Row) Series 77 Steam Unit (2-Row) Hartzell direct drive steam unit heaters are powered to utilize the full high heat transfer efficiency of the unit by efficient translation of power into air movement. The characteristics which make a unit heater so superior to heating devices which depend on radiation are the ability to quickly extract a very high proportion of the heat contained within the primary heating element and to distribute that heat evenly. The key to economy and quality of performance lies in the propeller which forces air through the heater and distributes it evenly and thoroughly into all corners and recesses of the area to be heated. The Hartzell steam unit heater is equipped with either 1-row coils (Series 771) or 2-row coils (Series 772) of the fin and tube type, high efficiency cast aluminum propeller direct connected to a totally enclosed fan duty motor. Two 1/2 13 N.C. tapped holes for support rods provided. See page 3 for performance data. Special coil sections may be provided to meet specific application requirements. The Cores in unit heaters have copper headers and seamless copper tubes with copper brazed joints, and copper fins. Varied fin spacing. Cores are guaranteed up to 150 psig saturated steam and 366 F. Standard mounting of the steam unit heater is in vertical position, capable of being tilted as much as 60 downward. Rugged steel support rods and motor base are standard on Hartzell steam unit heaters. The Ideal Heating Unit Initial Cost Lower per square foot of area to be heated than any other method of heating. Installation Cost May be installed in about a fourth of the time required for radiation. Heat Circulation Distributes heat thoroughly. Eliminates cold spots and cold floors. Space Saving Suspended along a wall, beam or ceiling, the average Hartzell unit heater saves at least 45 square feet of usable floor space. Instant Action Touch a switch when heat is needed (or do nothing at all if thermostatic control is used) and heat is produced instantly... no waiting. Louvers Adjustable louvers can be individually set to deliver heat at the exact point desired. Appearance Fabricated steel cabinet with air dry enamel coating. Tips on Placement of Unit Heaters Place units at the points of greatest heat loss (doorways, windows, etc.) Place heaters so that the air stream wipes the outside walls, and the throw from one heater reaches to the next unit. This sets up a circulatory air movement that produces a blanket of warm air along the cold wall. Arrange units so they do not blow directly on workers. Aim air streams down aisles, toward open spaces on the floor, or along exterior walls. Locate heaters so that air streams are not blocked by columns, machinery, partitions, etc. Position units in a building or exposed to a prevailing wind to direct a large portion of the heated air along the windward side. Accessories: Safety Guard Protective rear safety guard of 14 gauge steel is available as an option. 36

37 Dimensions and Performance Principle Dimensions Weight* Size A B C D E F G H J K L (lbs) / / /8 7 3 /8 2 1 /2 1 1 /2 4 7 /8 8 3 / / / / /8 9 1 /4 2 1 /2 1 1 /2 6 3 / / / / / / /8 9 1 /4 2 1 /2 1 1 /2 6 3 / / / / / / /8 9 1 /4 2 1 /2 1 1 /2 6 3 / / / / / / / / / / / /8 168 * Weight is less motor. Rating Table Series 771 and Series 772 Steam Unit Heater Performance Data 5 Pound Steam Pressure and 60 Entering Air Code No. 1-Row Coils 2-Row Coils No. Face Series 771 Face Series 772 Size Type BTU E.D.R. BTU E.D.R. (per hr.) F per hr. (sq. ft.) (per hr.) F per hr. (sq. ft.) of Blades HP RPM CFM Velocity (FPM) Final Temp. Lbs. cond. CFM Velocity (FPM) Final Temp. Lbs. cond. 12 OD3 4 1/ , , WE3 4 1/ , , ND3 2 1/ , , LF3 3 1/ , , WG3 4 3/ , , ND3 2 1/ , , NF3 2 1/ , , PH , , WF4 4 1/ , , NF3 2 1/ , , NG3 2 3/ , , WH , ,

38 Options and Accessories (Please note applicable series by each option/accessory item) Filter Box The addition of the filter box section to the gas air makeup unit enables tempered and filtered air to be brought into the building. Available for all models. Disposable or washable filters are available. Available for all units. Horizontal Inlet Weatherhood Effectively prevents the entry of weather during operation, and is designed to mount directly to the inlet of the unit that is installed horizontally outdoors; or when the unit is mounted horizontally indoors the weatherhood can be attached to the outside wall of the building. See page 10, installation type HI1 & HI2, HO1 & HO2 and V1. Available for all units. Vertical (Roof) Inlet Weatherhood These hoods are used when the unit is installed below the roof, and the weather hood is curb mounted above the roof. The foursided roof ventilator hood is a low velocity design to prevent entrainment of water, and is constructed of galvanized steel. This style hood can be used on models GFR 2,000 through 75,000 CFM. Connecting duct to the unit, by others. See page 10, installation types HI3 and HI4. Available Series SMP Vertical Unit only. Motor Operated Shutter Prevents the entry of outside air when unit is not in operation. Standard on steam units. Available for GFR, GMC, and GMP. Gas Regulators Various sizes and pressure capabilities available. Available for GFR, GMC, GMP, 78V or H, and 79. Vibration Isolators Spring type or rubber-in-shear available for entire unit or blower only. Available for GFR, GMC, GMP, and SFC. Perimeter Curb Mount Accommodates weather and leakage protection when the unit is mounted on a full perimeter pre-fabricated roof curb. Available for GFR, GMC, GMP, and SFC. Pre-fabricated Roof Curb Full perimeter mount with built-in wooden nailer strip that facilitates fastening the unit to the curb. Includes a rigid 1-1/2 thick, 3-pound density glass fiber liner, which eliminates condensation problems. 1/2 Neoprene sealer strip is standard. Construction is galvanized steel with fully welded seams. Available for GFR, GMC, GMP, and SFC Turning Elbow Turns the inlet or discharge airflow 90 degrees with the aid of guide vanes. Minimal friction loss. Available on GMC, GMP, and SMP. 2- and 4-way Diffusers Direct the discharge airflow. Available for GFR, GMC, GMP, and SFC. Service Platform Provides a safe and convenient station to service the unit. Available for GFR, GMC, GMP, and SFC 38

39 Options and Accessories (Please note applicable series by each option/accessory item) Combination Motor Cover and Belt Guard Provides weather protection as well as guarding of the drive sheave and belts. Available on SMP, SMC, SAH, AND SCH. Evaporative Cooling System Contact factory. Available on GMP and GMC. Door Guards Provide guarding of the internal drive assembly, by limiting access to the interior of the unit. Available for GFR, GMC, and GMP. Insulated Housings Single wall pinned insulation or double wall insulated construction. Available for GFR, GMC, GMP, and SFC. Cupro-Nickel Coil Can be substituted for standard coils at higher steam pressures. Offers increased coil life. Available on SFC, 77, SMP, SMC, SAH, and SCH. Room Temperature Control Provides floor control of unit s output temperature. Available for GFR, GMC, GMP, SFC, SMP, SMC, SAH, and SCH. Caution: The drive assembly on the periphery of the blades of a fan less than seven (7) feet above the floor or working level must be guarded to be in accordance with OSHA regulations. SHIPPING INFORMATION: Accessories are shipped separately with hardware available for field mounting and must be assembled to basic unit on job site. SAFETY ACCESSORIES, APPLICATION AND USE WARNING The safe application and use of equipment supplied by Hartzell Fan, Inc. is the responsibility of the installer, the user, the owner, and the employer. Since the application and use of its equipment can vary greatly, Hartzell Fan, Inc. offers various product types, optional safety accessories, and sound performance data per laboratory tests. Hartzell Fan, Inc. sells its equipment with and without safety accessories, and accordingly, it can supply such safety accessories only upon receipt of an order. The need for safety accessories will frequently depend upon the type of system, fan location and operating procedures being employed. The proper protective safety accessories to meet company standards, local codes, and the requirements of the Occupation Safety and Health Act must be determined by the user since safety requirements vary depending on the location and use of the equipment. If applicable local conditions, standards, codes or OSHA rules require the addition of the safety accessories, the user should specify and obtain the required safety accessories from Hartzell Fan, Inc. and should not allow the operation of the equipment without them. Owners, employers, users and installers should read RECOMMENDED SAFETY PRACTICES FOR USERS AND INSTALLERS OF INDUSTRIAL AND COMMERCIAL FANS published by the Air Movement and Control Association International, Inc., 30 West University Drive, Arlington Heights, Illinois A copy of this publication is enclosed with each fan shipped from Hartzell Fan, Inc., and is available upon request at Hartzell s office in Piqua, Ohio Please contact Hartzell Fan, Inc. or your local Hartzell representative for more information on product types, safety accessories, and sound performance estimates. Remember, the selection of safety accessories and the safe application and use of equipment supplied by Hartzell Fan, Inc. is your responsibility. 39

40 Hartzell Warranty LIMITED WARRANTIES Hartzell represents to Buyer that any goods to be delivered hereunder will be produced in compliance with the requirements of the Fair Labor Standards Act of 1938 as amended. Hartzell also warrants to Buyer its goods to be free from defects in workmanship and material under normal use and service for one (1) year after tender of delivery by Hartzell, plus six months allowance for shipment to approved stocking dealers and distributors. No warranty extends to future performance of goods and any claims for breach of warranty or otherwise accrues upon tender of delivery. The foregoing constitute Hartzell s sole and exclusive warranties and are in lieu of all other warranties, whether written, oral, express, implied or statutory. LIMITATION OF LIABILITY FOR BREACH OF WARRANTY Hartzell s obligation for any breach of warranty is limited to repairing or replacing, at its option, without cost to Buyer at its factory any goods which shall, within such a warranty period, be returned to it with transportation charges prepaid, and which its examination shall disclose to its satisfaction to have been defective. Any request for repair or replacement should be directed to Hartzell Fan, Inc., P.O. Box 919, Piqua, Ohio Hartzell will not pay for any repairs made outside its factory without its prior written consent. This does not apply to any such Hartzell goods which have failed as a result of faulty installation or abuse, or incorrect electrical connections or alterations, made by others, or use under abnormal operating conditions or misapplication of the goods. LIMITATION OF LIABILITY To the extent the above limitation of liability for breach of warranty is not applicable, the liability of Hartzell on any claim of any kind, including negligence, for any loss or damage arising out of or connected with, or resulting from the sale and purchase of the goods or services covered by these Terms and Conditions of Sale or from the performance or breach of any contract pertaining to such sale or purchase or from the design manufacture, sale, delivery, resale, installation, technical direction installation, inspection repair, operation or use of any goods or services covered by these Terms and Conditions shall, in no case exceed the price allocable to the goods or services which gave rise to the claim and shall terminate one year after tender of delivery of said goods or services, plus six months allowance for shipment to approved stocking dealers and distributors. In no event will Hartzell be responsible or liable for any labor or other incidental costs associated with the removal or replacement of defective products or materials. In no event whether as a result of breach of contract, or warranty or alleged negligence, defects, incorrect advice or other causes, shall Hartzell be liable for special or consequential damages, including, but not limited to, loss of profits or revenue, loss of use of the equipment or any associated equipment, cost of substitute equipment, facilities or services, down time costs, or claims of customers of the Buyer for such damages. Hartzell neither assumes nor authorizes any person to assume for it any other liability in connection with the sale of its goods or services. NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS DOES NOT WARRANT THAT SAID GOODS ARE OF MERCHANTABLE QUALITY OR THAT THEY ARE FIT FOR ANY PARTICULAR PURPOSE. THERE IS NO IMPLIED WARRANTY OF MERCHANTABILITY AND THERE IS NO IMPLIED WARRANTY OF FITNESS. Propeller Fans Cooling Tower & Heat Exchanger Fans Duct Fans Duct Axial Fans Vaneaxial Blowers Cool Blast & Utility Fans Steel Centrifugal Blowers Roof Ventilators Steel & Fiberglass Heating Equipment Gas & Steam Fiberglass Axial Flow Fans Fiberglass Centrifugal Blowers Hartzell Fan, Inc., Piqua, Ohio Plants in Piqua, Ohio and Portland, Indiana. Marine Mine Duty Blowers Litho in U.S.A. A-125-E 1/11

Direct Gas-Fired Make-Up Air

Direct Gas-Fired Make-Up Air Direct Gas-Fired Make-Up Air Model TSU Heavy Duty, High Airflow Applications Manufacturing and Industrial Facilities Up to 64,000 cfm August 2012 Products Model TSU Direct Gas-Fired Make-Up Air Unit The

More information

Indirect Gas-Fired Make-Up Air

Indirect Gas-Fired Make-Up Air Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041 Product Features Model IG Indirect Gas-Fired Make-Up

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation Industrial Space Heating Direct Gas-Fired Heating Greenheat 00% Outdoor Air Greenheat 50/50 Recirculation 80/0 Recirculation March 008 Product Overview Industrial Space Heating Greenheck s space heating

More information

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260)

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260) Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN 46706 (260) 925-6550 Fax: (260) 925-6093 Industrial Facility Midwest Re: Facility Ventilation Audit Schust Engineering, Inc. is pleased

More information

Modular Heating & Ventilating Unit Model IGX-HV

Modular Heating & Ventilating Unit Model IGX-HV Modular Heating & Ventilating Unit Model IGX-HV Indirect Gas-Fired Heating Evaporative Chilled Water DX Cooling October 2008 Product Features Model IGX-HV Indirect Gas-Fired Heating and Ventilating Unit

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters. SECTION 15622 DIRECT GAS-FIRED BURNER & MANIFOLD SYSTEM PART 1: GENERAL 1.1 Section includes: A. Direct gas-fired heater modules B. Controls C. Equipment schedule 1.2 Related Sections A. Section 01655:

More information

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You. TGIF- Indirect Fired Heating Systems Technical Guide for: IF Indoor Installations IFW Outdoor Installations Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide In the business of

More information

GLOBAL FINISHING SOLUTIONS

GLOBAL FINISHING SOLUTIONS GLOBAL FINISHING SOLUTIONS > Eliminate problems with drafts, stale or contaminated air, and temperature stratification > Create balanced building pressure and maintain proper comfort levels > Introduce

More information

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

Contents INDEX. TDM Series Indirect Fired Heaters

Contents INDEX. TDM Series Indirect Fired Heaters Contents Typical Indoor Installations................... 000 Indoor Unit Dimensions (Vertical).............. 000 Indoor Unit Dimensions (Horizontal)............ 000 Outdoor Unit Dimensions.....................

More information

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You TGIFR IFR Indirect Fired Gas Heating Systems Technical Guide for: Outdoor Rooftop Mounted Units To 46,000 CFM And 4,000 MBH Output Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide

More information

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

A. General: Refer to paragraph entitled SUBMITTAL in Section Include the following data: SECTION 15860 - FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR MECHANICAL

More information

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS SECTION 237339 - DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

Gas-Fired Indoor and Outdoor Duct Furnaces

Gas-Fired Indoor and Outdoor Duct Furnaces July, 2008 Gas-Fired Indoor and Outdoor Duct Furnaces INDOOR GRAVITY VENTED DFG, DBG, DCG INDOOR SEPARATED COMBUSTION DFS, DBS, DCS OUTDOOR GRAVITY AND POWER EXHAUSTED H Series table of contents A complete

More information

Make-Up Air March 2012

Make-Up Air March 2012 Make-Up Air March 2012 Comfortable energy efficient kitchen ventilation starts here. At Larkin Industries, our goal is to manufacture well-designed kitchen ventilation systems with environmentally sustainable

More information

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST S Model TCBS CATALOG AX220 May 2013 TubeaxialFans Model TCBS The Twin City Fan & Blower model TCBS is a belt driven tubeaxial fan that is

More information

Equipment Specifications

Equipment Specifications Equipment Specifications GAS/OIL HEATING ONLY INDIRECT-FIRED AIR HANDLER GUIDE SPECIFICATION PART 1 GENERAL [Gas][Oil][Gas/Oil Combo]-Fired Please note: Brackets indicate required choices to be made in

More information

Counterflo CF BASIC COUNTERFLO HEATER RCF CURB MOUNTED ROOFTOP HEATER CFDF COUNTERFLO DUCT FURNACE INDIRECT-FIRED INDUSTRIAL HEATERS

Counterflo CF BASIC COUNTERFLO HEATER RCF CURB MOUNTED ROOFTOP HEATER CFDF COUNTERFLO DUCT FURNACE INDIRECT-FIRED INDUSTRIAL HEATERS Bulletin CF-1 May 2005 Supersedes CF-1 Dated February 1998 Counterflo INDIRECT-FIRED INDUSTRIAL HEATERS Self-contained, Automatic, Indirect-fired, Warm-air Heater C.S.A. APPROVED UNITS AVAILABLE Natural

More information

Direct Gas-Fired Make-Up Air Models DG and DGX

Direct Gas-Fired Make-Up Air Models DG and DGX Direct Gas-Fired Make-Up Air Models DG and DGX Commercial, Industrial and Kitchen Applications 800-48,000 cfm 4 in. wg External Static Pressure Direct Gas-Fired Heating Optional Cooling - Packaged DX (2.5

More information

SAS Steadyair Make-Up Air Units Technical Guide

SAS Steadyair Make-Up Air Units Technical Guide TGSAS-3 SAS Steadyair Make-Up Air Units Technical Guide A COMPLETE AIR TEMPERING PACKAGE FOR COMMERCIAL, INSTITUTIONAL, AND INDUSTRIAL APPLICATIONS S ince 1875, the L.J. Wing Company has been a leader

More information

FEATURES AND BENEFITS

FEATURES AND BENEFITS FEATURES AND BENEFITS Product Features and Benefits Full Product Line Offering Feature All models are 80% thermally efficient Blower performance up to 3.0 W.C. DX or chilled water section with factory

More information

Direct Gas-Fired Make-Up Air Models DGK, DG and DGX

Direct Gas-Fired Make-Up Air Models DGK, DG and DGX Direct Gas-Fired Make-Up Air Models DGK, DG and DGX Kitchen and Industrial Applications 800-48,000 cfm 4 in. wg External Static Pressure Direct Gas-Fired Heating Packaged DX (3 to 16 tons), Split DX Cooling,

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 233423 - HVAC POWER VENTILATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 PERFORMANCE REQUIREMENTS A. Operating

More information

Combat. DF-Series Direct-Fired Heating, Cooling and Pressurization Systems. Equipment Specifications

Combat. DF-Series Direct-Fired Heating, Cooling and Pressurization Systems. Equipment Specifications Combat DF-Series Direct-Fired Heating, Cooling and Pressurization Systems Equipment Specifications 800.828.7450 www.rg-inc.com CANADA: 100% OUTSIDE AIR ONLY DIRECT-FIRED AIR HANDLERS GUIDE SPECIFICATION

More information

INDIRECT GAS-FIRED AIR HEATER

INDIRECT GAS-FIRED AIR HEATER INDIRECT GAS-FIRED AIR EATER DG() SERIES INDOOR/OUTDOOR INSTALLATION MANUFACTURED BY TABLE OF CONTENTS Description... Applications... Selection criteria... Installation guidelines... Selection table...7

More information

THREE-WAY HEAT SAVER/VENTILATOR

THREE-WAY HEAT SAVER/VENTILATOR BULLETIN 673 December 2009 THREE-WAY HEAT SAVER/VENTILATOR Modulated Damper Control System Operates in Supply, Exhaust, Heat Saver and Mixed-Air Modes Models RREH & RRES Three-Way Heat Saver/Ventilator

More information

KIC Air Curtains. Technical Guide

KIC Air Curtains. Technical Guide TGKIC-3 KIC Air Curtains Technical Guide AIR PERFORMANCE AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. King certifies that the air curtains shown herein are licensed to bear the AMCA seal. The

More information

TYPICAL CPA SPECIFICATIONS

TYPICAL CPA SPECIFICATIONS TYPICAL CPA SPECIFICATIONS 4/10/2017 UNIT CONSTRUCTION: Casing: The exterior casing of the unit shall be constructed of 18-gauge, G235 galvanized steel (optional stainless steel or aluminum), unpainted.

More information

FAS Fresh Air Supply Units

FAS Fresh Air Supply Units TGFAS-2 FAS Fresh Air Supply Units TECHNICAL GUIDE STEAM AND HOT WATER MAKE-UP AIR HEATERS WITH INTEGRAL FACE AND BYPASS COILS FOR EFFECTIVE TEMPERATURE CONTROL Since 1875, the L.J. Wing Company has been

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

KEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters. Table of Contents FOR YOUR SAFETY.

KEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters. Table of Contents FOR YOUR SAFETY. KEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters Table of Contents FOR YOUR SAFETY Page # Topic If you smell gas: 1 Description of Operation 1 Receiving the

More information

Directflow SBDR/SBD SERIES

Directflow SBDR/SBD SERIES Bulletin SBDR/SBD-1 January 2015 Supersedes SBDR/SBD-1 Dated April 2014 Directflow SBDR/SBD SERIES DIRECT GAS-FIRED MAKE-UP AIR SYSTEMS Cooling Can Be Added A MODEL FOR EVERY APPLICATION SBD Direct Gas-Fired

More information

BANANZA. B-Series Direct-Fired Heating, Cooling And Pressurization Systems. Equipment Specifications

BANANZA. B-Series Direct-Fired Heating, Cooling And Pressurization Systems. Equipment Specifications BANANZA B-Series Direct-Fired Heating, Cooling And Pressurization Systems Equipment Specifications 1.800.255.3416 www.bananza.com CANADA: 100% OUTSIDE AIR ONLY DIRECT-FIRED AIR HANDLER GUIDE SPECIFICATION

More information

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004 Engineering Bulletin Gas Heat for M-Series and T-Series Climate Changer Air Handlers March 2004 CLCH-PRB010-EN Preface Gas heat can be a good heating option for any of the following applications: Climates

More information

GA Gas Unit Heater Assemblies Technical Guide

GA Gas Unit Heater Assemblies Technical Guide TGGA-2 GA Gas Unit Heater Assemblies Technical Guide INDIRECT-FIRED GAS HEATING ASSEMBLIES FOR LARGE OPEN SPACES AND DOOR HEATING APPLICATIONS S ince 7, the L.J. Wing Company has been a leader in providing

More information

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Construction Standards Page 233423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified

More information

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013 SECTION 15800 - AIR HANDLING EQUIPMENT 1.1 GENERAL A. All air handlers installed shall conform to the University of Rochester specification Guideline for Semi-Custom and Pre-Engineered Air Handling Units.

More information

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters. Section 15 _ Energy Recovery Air Handling System Part 1: GENERAL 1.1 Section Includes: A. Energy Recovery Air Handler B. Controls (most by Others) C. Equipment Schedule 1.2 Related Sections: A. Section

More information

Introduction to Fans. The Basics of Fan Principles and Terminology

Introduction to Fans. The Basics of Fan Principles and Terminology Introduction to Fans The Basics of Fan Principles and Terminology Airflow Principles A fan is a rotating device that creates pressure differential that results in air movement Pressure rise in a fan Downstream

More information

Directflow SBDR/SBD SERIES

Directflow SBDR/SBD SERIES Bulletin /SBD-1 June 2005 Supersedes SBD-1 Dated February 2005 and -1 Dated March 2001 Directflow /SBD SERIES DIRECT GAS-FIRED MAKE-UP AIR SYSTEMS Cooling Can Be Added A MODEL FOR EVERY APPLICATION SBD

More information

AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS

AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS FPAC FPMC FPDA CATALOG AX351 JULY 2001 WWW.TCF.COM

More information

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS SECTION 23 34 16 CENTRIFUGAL HVAC FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Drawings and general provisions of the contract, including General and Special Conditions and Division 01 Specification

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Placement within a mechanical room is required for all major mechanical equipment. Only small units may be roof-mounted, and shall be made as inconspicuous

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

Air Replacement Systems

Air Replacement Systems G L O L F I N I S H I N G S O L U T I O N S ir Replacement Systems > Eliminate problems with drafts, stale or contaminated air, and temperature stratification > reate balanced building pressure and maintain

More information

Air Make-Up Units. Product Line Overview & Capabilities

Air Make-Up Units. Product Line Overview & Capabilities Air Make-Up Units Product Line Overview & Capabilities Air Make-Up Units Customized Solutions Unmatched Flexibility As one of the most sophisticated manufacturers of Air Make-Up Units, Aerovent s unique

More information

SECTION AIR HANDLING UNIT

SECTION AIR HANDLING UNIT SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR

More information

Air Replacement Systems

Air Replacement Systems GLOL FINISHING SOLUTIONS ir Replacement Systems > Eliminate problems with drafts, stale or contaminated air, and temperature stratification > reate balanced building pressure and maintain proper comfort

More information

Fans: Features and Analysis

Fans: Features and Analysis Technical Development Program COMMERCIAL HVAC EQUIPMENT Fans: Features and Analysis PRESENTED BY: Michael Ho Version 1.2 Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Section

More information

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS SECTION 237413 - PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, outdoor, central-station air-handling units (rooftop units) with the

More information

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March GENERAL: 1. This section provides criteria for the design and installation of air handling units. DESIGN GUIDELINES: Design General 1. Location 1.1. For new construction, and existing buildings where possible,

More information

Selecting the Correct Fan

Selecting the Correct Fan Selecting the Correct Fan Ryan B. Johnson Air Purification Company Sales Engineer Member, ASHRAE Pikes Peak Chapter rjohnson@airpurificationcompany.com 1 Your Speaker circa 1998 Fan Types Applications

More information

1.1 This section applies to air handling units for HVAC Systems.

1.1 This section applies to air handling units for HVAC Systems. AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling

More information

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGF SERIES 7-1/2 Ton C Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Combination gas heating and electric cooling, self contained for year-round comfort. Systems can be installed

More information

Field Start-Up Sheet Direct Fired Gas Equipment

Field Start-Up Sheet Direct Fired Gas Equipment Customer: Sales Representative: Model Number: Serial Number: Field Start-Up Sheet Direct Fired Gas Equipment ***Please Print*** INITIAL INSPECTION I. Installer Responsibilities 1. Remote Panel: All interconnecting

More information

Section (CSI ) I-Series Drum & Tube (04/23/10) Indirect-Fired Heating & Ventilating

Section (CSI ) I-Series Drum & Tube (04/23/10) Indirect-Fired Heating & Ventilating Section 15700 (CSI 23 74 33) I-Series Drum & Tube (04/23/10) Indirect-Fired Heating & Ventilating Note: Optional items and/or items requiring a choice, will be shown between brackets and/or parentheses

More information

STR-Series Indirect-Fired Air Turnover Units

STR-Series Indirect-Fired Air Turnover Units STR-Series Indirect-Fired Air Turnover Units Equipment Specifi cations 1.800.589.3691 www.weather-rite.com GAS/OIL HEATING ONLY INDIRECT-FIRED AIR TURNOVER UNIT GUIDE SPECIFICATIONS PART 1 GENERAL [Gas][Oil][Gas/Oil

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN AX351 July 2001 AXICO ANTI-STALL Controllable Pitch-In-Motion and Adjustable Pitch-At-Rest Vaneaxial Fans Types FPAC, FPMC, FPDA A complete product bulletin including performance

More information

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP CATALOG 9-117.1 JUNE, 2003 TABLE OF CONTENTS Modine's TLP Series sets the industry standard for low intensity infrared heating performance

More information

Submittal Data Performance Data Electrical Data

Submittal Data Performance Data Electrical Data ERMS Series Submittal Data Submittal Data Unit Designation: Job name: Architect: Engineer: Contractor: Performance Data Revision: 07/01/11 Cooling Capacity: EER: Heating Capacity: COP: Ambient Air Temp:

More information

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents TABLE OF CONTENTS A complete line of commercial, industrial, and residential heating equipment is offered. This catalog describes in detail the gas-fired, gravity and power vented, commercial/ industrial

More information

A. Codes and Standards that are Standard at the University:

A. Codes and Standards that are Standard at the University: PART 1: GENERAL 1.01 Purpose: 1.02 References: 1.03 Requirements: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The

More information

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT Fans, Heaters & Controls 1 GRAIN CONDITIONING EQUIPMENT SIOUX STEEL COMPANY Innovative Solutions Manufactured By A Family-Owned Company With A ENGINEERING

More information

Bulletin FH05 FUME EXHAUST

Bulletin FH05 FUME EXHAUST Bulletin FH05 FUME EXHAUST Models: FH, FHL Curb Mounted Centrifugal Fans Fume Exhaust Systems - FH/FHL Introduction The PennBarry FH fans are designed to meet the various requirements for fume exhaust

More information

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004) High Plume Blowers Suggested Specification Section 15500 (Master Format 1996) Suggested Specification Section 23 38 16 (Master Format 2004) PART 1 GENERAL 1.01 WORK INCLUDED High Plume Laboratory Exhaust

More information

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems. 15855 AIR HANDLING UNITS SPECIFIER: CSI MasterFormat 2004 number: 237313 PART 1 GENERAL 1.1 SUMMARY A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution

More information

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS 48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,

More information

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGB SERIES 3thru5Ton 10 SEER C CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Combination gas heating and electric cooling, self contained for year-round comfort. Systems can be installed

More information

The H Series. Pure and Simple Solutions. HTLV Space Heating

The H Series. Pure and Simple Solutions. HTLV Space Heating The H Series Pure and Simple Solutions HTLV Space Heating Proven alternative to blow-through design Design flexibility & application versatility Optimized IAQ & occupant comfort The H Series AbsolutAire

More information

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU) AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory

More information

SECTION (15833) - HVAC POWER VENTILATORS

SECTION (15833) - HVAC POWER VENTILATORS PART 1 GENERAL 1.01 SUMMARY SECTION 23 34 23 (15833) - HVAC POWER VENTILATORS A. Section Includes: 1. Centrifugal Roof Ventilators. 2. Up-blast Roof Exhaust Fans (Kitchen Hood Exhaust). 3. Ceiling-Mounted

More information

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

ENVIRO UNIT ENGINEERING MANUAL KES SERIES ENVIRO UNIT ENGINEERING MANUAL KES SERIES The Cadexair INC. Enviro System (KES) and Recirculation System (KRS) have been designed and constructed specifically for a commercial kitchen exhaust. The units

More information

Cabinet Unit Heaters Steam / Hot Water

Cabinet Unit Heaters Steam / Hot Water 11-160.4 February, 2005 Cabinet Unit Heaters Steam / Hot Water Model C MODEL IDENTIFICATION Table of Contents I. Model Identification... 3 Page Il. IIl. III. IV. Design Benefits A. Features and Benefits...

More information

Industrial Fans & Blowers

Industrial Fans & Blowers Industrial Fans & Blowers IN-LINE FANS ADD DIRECT DRIVE TUBEAXIAL FANS FEATURES & BENEFITS Spark resistant, cast aluminum airfoil axial impeller Aerodynamically efficient performance Factory set adjustable

More information

XeteX, Inc. All Rights Reserved.

XeteX, Inc. All Rights Reserved. Model DXH Custom, packaged, roof mounted or indoor mounted unit with cooling (DX or Chilled Water) and an air-to-air aluminum flat plate exchanger designed to provide pre-cooling and reheat. The DXH is

More information

MXI Mixed Flow Inline Fan

MXI Mixed Flow Inline Fan MXI Mixed Flow Inline Fan PRODUCT GUIDE PennBarry Your Single Source for Commercial & Industrial Supply & Exhaust Fans www.pennbarry.com TABLE OF CONTENTS INTRODUCTION 3 CERTIFICATIONS & LISTINGS 4 MIXED

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN AX010 November 2005 AXIAL POWER ROOF VENTILATORS Power Roof Ventilators Twin City Fan & Blower offers a wide variety of Power Roof Ventilators (PRVs). The PRVs have been

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name University of Houston Master Construction Specifications Insert Project Name SECTION 23 82 20 - FANS, AIR INTAKES AND RELIEF VENTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing Important: To protect the unit and avoid damage to the heat exchanger, the blower speed

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/ 1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5

More information

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications Bulletin C6200 MAY 20 3 Buffalo Air Handling Big Buffalo Custom Applications Buffalo Air Handling Big Buffalo The historic strength of Buffalo Air Handling is the custom designed air handling equipment

More information

DCG Commercial. Submittal Data Form

DCG Commercial. Submittal Data Form DCG Commercial Submittal Data Form 15-25 Tons Packaged Gas / Electric Units 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h 15 Tons

More information

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

More information

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS -3SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING S PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier Corporation

More information

Catalog Destiny Indoor Air Handler. Models Horizontal Configuration. Vertical Configuration

Catalog Destiny Indoor Air Handler. Models Horizontal Configuration. Vertical Configuration Destiny Indoor Air Handler Models 002 030 Catalog 580-8 Horizontal Configuration Vertical Configuration Table of Contents Introduction.... 2 Certification...2 Smoke Control and Management Systems...2 Features

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division AMERICAN COOLAIR CORPORATION Greenhouse Ventilation Systems Farm Products Division AL Aluminum Greenhouse Fan American Coolair s AL all-aluminum fans are the answer to concerns about rust and corrosion

More information

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15732 - PACKAGED ROOFTOP AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Package roof top unit. B. Heat exchanger. C. Refrigeration components. D. Unit operating controls. E. Roof

More information

Glossary of Terms Laboratory & Fume Exhaust Fans

Glossary of Terms Laboratory & Fume Exhaust Fans Glossary of Terms Laboratory & Fume Exhaust Fans ACTUATOR, 2-POSITION SPRING RETURN A spring return actuator generally used to control the isolation dampers below the fans. This actuator allows for fully

More information

SECTION AXIAL FANS

SECTION AXIAL FANS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT -1SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP S W/OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier

More information

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES SECTION 15856 MODULAR AIR HANDLING UNITS PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. NFPA Compliance: Modular air handling units and components shall be designed, fabricated, and installed in compliance

More information

SECTION ROOFTOP REPLACEMENT AIR UNITS

SECTION ROOFTOP REPLACEMENT AIR UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Specification Sections, apply to this Section. B. Related

More information

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for: Date: 05/21/2001 Time: 08:50:16 AM Job Name: EarthWise Modular Climate Changer Full Spec Location: Any Town, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SUBMITTALS Submittals

More information