Suggested Schematics with Control and Power Wiring details

Size: px
Start display at page:

Download "Suggested Schematics with Control and Power Wiring details"

Transcription

1 00 P Suggested Schematics with Control and Power Wiring details Outside Sensor Mount in a sheltered position on orth facing wall ocal temp control Under floor HTG 0v Supply Mains cold water ocal temp control Condensate mm Flow mm Return mm Gas High Temp diverting valve Under floor HTG ow loss header System pump AVS000

2 Benchmark places responsibilities on both manufacturers and installers. The purpose is to ensure that customers are provided with the correct equipment for their needs, that it is installed, commissioned and serviced in accordance with the manufacturer s instructions by competent persons and that it meets the requirements of the appropriate Building Regulations. The Benchmark Checklist can be used to demonstrate compliance with Building Regulations and should be provided to the customer for future reference. Installers are required to carry out installation, commissioning and servicing work in accordance with the Benchmark Code of Practice which is available from the Heating and Hotwater Industry Council who manage and promote the Scheme. Visit for more information. Contents AVATA PUS System Options O / Off Control (Internal modulating). Typical Y plan Heating and using 0v controls. Typical W plan Heating and Priority using 0v controls 6. Typical S plan Heating and using 0v controls 7. Internal time clock Heating and Priority using Celcia 0 and way diverting valve kit 8 Weather Compensation Control Direct modulating using OpenTherm. Simple weather compensated Heating with Priority 9 6. Simple weather compensated Heating with room thermostat override (0v) and Priority 0 7. Simple weather compensated Heating with room thermostat override (Celcia0) and Priority 8. Time / Weather compensated Heating with Priority (Celcia 0 -Digital clock) Room Compensation Control Direct modulating using OpenTherm 9. Simple room compensated Heating using the Celcia and Priority 0. Time / Room compensated Heating with Priority (Celcia 0 - Digital clock) AVATA PUS Combi Options O / Off Control (Internal modulating). Timed heating with constant using external time clock and room thermostat (0v). Timed heating with constant using internal time clock (0v) and room thermostat (Celcia 0) 6 Weather Compensation Control Direct modulating using OpenTherm. xternal time clock with simple weather compensated Heating and constant 7. Internal time clock with simple weather compensated Heating and constant 8. Time / Room compensated Heating using the Celcia 0 (Digital clock) and constant 9 Room Compensation Control Direct modulating using OpenTherm 6. xternal time clock with simple room compensated Heating using the Celcia and constant 0 7. Internal time clock with simple room compensated Heating using the Celcia and constant 8. Time / Room compensated Heating with Priority (Celcia 0 - Digital clock) AVATA PUS Underfloor Heating Options (Combi & System) Weather Compensation Control Direct modulating using OpenTherm 9. System boiler - Internal time clock with simple weather compensated UF Heating and priority 0. Combi boiler - Internal time clock with simple weather compensated UF Heating and constant AVATA v/8v/v Open Vented Options (System only). Typical Y plan Heating and using 0v controls. Typical W plan Heating and Priority using 0v controls 6. Typical S plan Heating and using 0v controls 7 Weather Compensation Control Direct modulating using OpenTherm. Simple weather compensated Heating with Priority 8. Simple weather compensated Heating with 0v room thermostat override and Priority 9 6. Simple weather compensated Heating with volt free room thermostat override and Priority 0

3 IMPORTAT OT: The layouts illustrated in this brochure are for guidance only and do not constitute a full system design. All Mechanical and lectrical equipment must be installed in accordance with the instructions supplied, by a suitably qualifi ed ngineer and to the current regulations Controls for the AVATA PUS and AVATA v/8v/v Boilers The AVATA series are fully condensing boilers using gas / air ratio controls to provide full modulation and can be operated in the following modes. All boilers require a permanent 0v single phase amp fused power supply plus controls as below: OT: The boiler is phase / neutral sensitive when used with external 0v controls. O / OFF Control fi xed fl ow temperature where the boiler modulates it s output to match a fi xed fl ow set point using simple 0v switching controls: Single or Two channel time clock (internal only available on the 8s/s/c/0s/8c/c/9c) Room thermostat Cylinder thermostat Diverting / mixing or isolating valves MODUATIG Control fl ow temperature is directly controlled by the outside weather or inside room compensator to provide comfort conditions at all times using OpenTherm controls: Outside sensor sensor or cylinder thermostat Room compensator Digital time/weather or room compensator Mechanical time/ analogue weather or room compensator Controls available from Broag as optional extras S6 Internally mounted two channel digital time clock kit (not for the Avanta v/8v/v) S6c Internally mounted single channel digital time clock (for the Combi series only) 0 Outside sensor S96 sensor S97 Room thermostat - Celcia 0 S96 Room compensator - Celcia 8 Wall mounted Digital Time / Weather compensator - Celcia 0 (outside sensor not included) TG00 Wall mounted Analog Time / Weather compensator - Theben DA00 Wall mounted two channel hour time clock (0v switching) DA00 Wall mounted two channel 7 day time clock (0v switching) KT806 Wall wireless room thermostat kit Typical controls by others xternal mounted simple two channel time clock providing, 0v switched supplies to time control heating and domestic hot water eg. typical Honeywell ST699 or similar Cylinder thermostat eg. typical Honeywell 6 or similar Room thermostat eg. typical Honeywell T660 or similar HTG and zone valves c/w a single end switch (closes on valve fully open) eg. Honeywell V0H or similar Wiring centre Y / W / S Plan - complete kits Other manufacturer s compatible OpenTherm time and temperature controls When fi tting the diverting valve on a priority system note the orientation of the ports i,e AB, A, and B, they may not be consistent with the instructions supplied with the valve.

4 When using the AVATA PUS Combi boiler, is always set for constant operation (not timed) but can if required be changed to allow for time restriction using a two channel time clock. If required the AVATA series can report a common alarm or boiler run condition to an external control panel or BMS by using the connections on terminal block X7. s and - Common alarm s and - Boiler run / external gas valve / external pump relay These are both volt free (max capacity 0v amp ) and are open contacts which close on common alarm or boiler run respectively (see Installation and Technical booklet for futher opions). Pre and After Sales Service Our dedicated pre-and-after-sales teams are ready to give you the support you need. It s an integral part of the quality package that Broag offers as standard with all products. Contact Information Sales: After Sales: iterature: Training: Technical: Spares:

5 AVATA PUS System Option Typical Y plan Heating and using 0v controls Channel Time clock Room Stat 0v Supply Wiring Centre mm Return Condensate mm Flow mm Gas 'A' HTG Three way Mid position valve - HTG and/or 'AB' high output Calorifier thermostat 'B' Check valve may be necessary AVS000 Wiring Centre 6 Cylinder Thermostat C CA ST699 Control OFF O OFF O HTG Clock CA T660/T60 Room Thermostat Remove exist links X Blue G/Yellow White Grey Orange 'B' X6 0v Power Supply AB V07 Mid Position Valve 0v amp Switched Spur Boiler AVW000

6 AVATA PUS System Option Typical W plan Heating and Priority using 0v controls Channel Time clock Room Stat 0v Supply Wiring Centre mm Return Condensate mm Flow mm Gas 'A' HTG Three way Diverting valve - HTG or 'AB' high output Calorifier c/w thermostat 'B' Check valve may be necessary AVS000 6 Cylinder Thermostat C CA Wiring Centre ST699 Control OFF O OFF O HTG Clock CA T660/T60 Room Thermostat Remove exist links X Blue G/Yellow Brown 'A' HTG 'B' X6 0v Power Supply 6 AB V0c Diverting Valve 0v amp Switched Spur Boiler AVW000

7 AVATA PUS System Option Typical S plan Heating and using 0v controls Channel Time clock Room Stat 0v Supply Wiring Centre mm Return Condensate HTG Zone Valve c/w end switches mm Flow mm Gas Zone Valve c/w end switches Cylinder Stat AVS000 6 Cylinder Thermostat C Call Wiring Centre ST699 Control OFF O OFF O HTG Clock Call T660/T60 Room Thermostat V0H Zone Valve nd Switch Close on fully open Remove exist links X V0H HTG Zone Valve nd Switch Closeonfully open X6 0v Power Supply 0v amp Switched Spur Boiler AVW000 7

8 AVATA PUS System Option Internal time clock - Heating and Priority using Celcia 0 and way diverting valve kit 8

9 AVATA PUS System Option Simple weather compensated Heating with Priority 9

10 AVATA PUS System Option 6 Simple weather compensated Heating with room thermostat override (0v) and Priority 0

11 AVATA PUS System Option 7 Simple weather compensated Heating with room thermostat override (Celcia 0) and Priority

12 AVATA PUS System Option 8 Time / Weather compensated Heating with Priority (Celcia 0 - Digital clock)

13 AVATA PUS System Option 9 Simple room compensated Heating using the Celcia and Priority OT: With a 0v switching time clock a frost thermostat, if required, must be connected in parallel with the time clock on terminal strip X connectors and (frost stat contacts to close on temperature fall)

14 AVATA PUS System Option 0 Time / Room compensated Heating with Priority (Celcia 0 - Digital clock)

15 AVATA PUS Combi Option Timed heating with constant using external time clock and room thermostat (0v) OT: With a 0v switching time clock a frost thermostat, if required, must be connected in parallel with the time clock on terminal strip X connectors and (frost stat contacts to close on temperature fall) Two channel time clock Room thermostat (0v) Mount in a reference room.m above floor away from any heat scource 0v Supply Mains cold water Condensate mm Flow mm Gas mm Return AVS00 Block X6 0v - Amp Power Supply (via switched spur) Block X Block X9 xist link xist links Block X CA Room thermostat (0v switching) xternal Time clock Two channel - 0v switching O HTG OFF Remove link to To provide time control over remove link / in X and install wiring from time clock ( on control) to terminal O OFF AVW00 OT: blocks are not in line as shown - diagramatic only

16 AVATA PUS Combi Option Timed heating with constant using internal time clock (0v) and room thermostat (Celcia 0) OT: With a 0v switching time clock a frost thermostat, if required, must be connected in parallel with the time clock on terminal strip X connectors and (frost stat contacts to close on temperature fall) Room thermostat (Celcia 0) Mount in a reference room.m above floor away from any heat scource 00 P 0v Supply Mains cold water Condensate mm Flow mm Gas mm Return AVS00 Block X6 0v - Amp Power Supply (via switched spur) Block X Block X9 xist link xist link Remove xist link CA Room thermostat (volt free) ie: Celcia 0 Block X Internal Time clock - Twin channel 0v switching c/w cable and plug ote:clock has channel disabled for hr operation CH - CH- HTG 6 Remove xist Plug from X Plug clock into X AVW00 OT: blocks are not in line as shown - diagramatic only

17 AVATA PUS Combi Option xternal time clock with simple weather compensated Heating and constant Two channel time clock Outside Sensor Mount in a sheltered position on orth facing wall 0v Supply Mains cold water Condensate mm Flow mm Gas mm Return AVS00 Block X6 0v - Amp Power Supply (via switched spur) Block X Block X9 Outside Sensor (red band) xist link xist links 6 7 Block X 8 xternal Time clock Two channel - 0v switching O OFF HTG To provide time control over remove link / in X and install wiring from time clock ( on control) to terminal O OFF Remove link to AVW00 OT: blocks are not in line as shown - diagramatic only 7

18 00 AVATA PUS Combi Option Internal time clock with simple weather compensated Heating and constant Outside Sensor Mount in a sheltered position on orth facing wall P 0v Supply Mains cold water Condensate mm Flow mm Gas mm Return AVS009 Block X6 0v - Amp Power Supply (via switched spur) Block X Block X9 Outside Sensor (red band) xist link xist links Block X Internal Time clock - Twin channel 0v switching c/w cable and plug ote:clock has channel disabled for hr operation CH - CH- HTG Remove xist Plug from X Plug clock into X 8 AVW009 OT: blocks are not in line as shown - diagramatic only

19 AVATA PUS Combi Option Time / Room compensated Heating using the Celcia 0 (Digital clock) and constant Time / Weather compensator (Celcia 0) Mount in a reference room.m above floor away from any heat scource Outside Sensor Mount in a sheltered position on orth facing wall 0v Supply Mains cold water Condensate mm Flow mm Gas mm Return AVS007 Block X6 0v - Amp Power Supply (via switched spur) Block X Block X9 Outside Sensor (red band) Remove xist link xist link Remove xist link Block X O-T Bus xist links Time/Weather compensator Celcia 0 AVW007 OT: blocks are not in line as shown - diagramatic only 9

20 AVATA PUS Combi Option 6 xternal time clock with simple room compensated Heating using the Celcia and constant OT: With a 0v switching time clock a frost thermostat, if required, must be connected in parallel with the time clock on terminal strip X connectors and (frost stat contacts to close on temperature fall) Two channel time clock Modulating thermostat (Celcia ) Mount in a reference room.m above floor away from any heat scource 0v Supply Mains cold water Condensate mm Flow mm Gas mm Return AVS00 Block X6 0v - Amp Power Supply (via switched spur) Block X Block X9 xist link xist link Remove xist link Block X A C Room compensator Celcia xternal Time clock Two channel - 0v switching O OFF HTG 0 To provide time control over remove link / in X and install wiring from time clock ( on control) to terminal O OFF Remove link to AVW00 OT: blocks are not in line as shown - diagramatic only

21 00 AVATA PUS Combi Option 7 Internal time clock with simple room compensated Heating using the Celcia and constant OT: With a 0v switching time clock a frost thermostat, if required, must be connected in parallel with the time clock on terminal strip X connectors and (frost stat contacts to close on temperature fall) Room compensator (Celcia) Mount in a reference room.m above floor away from any heat scource P 0v Supply Mains cold water Condensate mm Flow mm Gas mm Return AVS00 Block X6 0v - Amp Power Supply (via switched spur) Block X Block X9 xist link Room compensator Celcia xist link 6 A C Remove xist link 7 8 Block X Internal Time clock - Twin channel 0v switching c/w cable and plug ote:clock has channel disabled for hr operation CH - CH- HTG Remove xist Plug from X Plug clock into X AVW00 OT: blocks are not in line as shown - diagramatic only

22 AVATA PUS Combi Option 8 Time / Room compensated Heating with Priority (Celcia 0 - Digital clock) Time / Weather compensator (Celcia 0) Mount in a reference room.m above floor away from any heat scource 0v Supply Mains cold water Condensate mm Flow mm Gas mm Return AVS008 Block X6 0v - Amp Power Supply (via switched spur) Block X Block X9 Remove xist link xist link Remove xist link Block X O-T Bus xist links Time/Weather compensator Celcia 0 AVW008 OT: blocks are not in line as shown - diagramatic only

23 AVATA PUS System Option 9 System boiler - Internal time clock with simple weather compensated UF Heating and priority OT: High temperature protection and local temperature controls for the under floor heating system not supplied by Broag

24 00 AVATA PUS Combi Option 0 Combi boiler - Internal time clock with simple weather compensated UF Heating and constant OT: High temperature protection and local temperature controls for the under floor heating system not supplied by Broag Outside Sensor Mount in a sheltered position on orth facing wall ocal temp control Under floor HTG P 0v Supply Mains cold water ocal temp control Condensate mm Flow mm Return mm Gas High Temp diverting valve Under floor HTG ow loss header System pump AVS000 Block X6 0v - Amp Power Supply (via switched spur) Block X Remove xist link xist links Block X9 Block X Remove xist Plug from X AVW Plug clock into X Outside Sensor (red band) Internal Time clock - Twin channel 0v switching c/w cable and plug ote:clock has channel disabled for hr operation OT: blocks are not in line as shown - diagramatic only CH - CH- HTG 00 x " BSP(F) Boiler side 90 x 90 Sq Steel tube 8. ctrs Suggested design of a low loss header Broag part o : G00 0 ctrs x /" BSP ( System side

25 AVATA v/8v/v System Only - Option Typical Y plan Heating and using 0v controls 0v Supply Channel Time clock Check valve may be necessary Wiring Centre thermostat 'B' Room Stat mm Flow 'AB' 'A' HTG Three way Mid position valve - HTG and/or mm Return Condensate AOVS00 mm Gas Wiring Centre 6 Cylinder Thermostat C CA ST699 Control OFF O OFF O HTG Clock CA T660/T60 Room Thermostat X Remove exist links System Pump Must be wired direct to boiler X 'A' HTG Blue G/Yellow White Grey Orange 'B' X6 0v Power Supply AB V07 Mid Position Valve 0v amp Switched Spur Boiler AOVW00

26 AVATA v/8v/v System Only - Option Typical W plan Heating and Priority using 0v controls 6

27 AVATA v/8v/v System Only - Option Typical S plan Heating and using 0v controls thermostat 0v Supply Channel Time clock Check valve may be necessary Wiring Centre Zone valve c/w end switches Room Stat mm Flow mm Return HTG Zone valve c/w end switches Condensate mm Gas AOVS00 6 Cylinder Thermostat C Call Wiring Centre ST699 Control OFF O OFF O HTG Clock Call T660/T60 Room Thermostat X V0H Zone Valve nd Switch Close on fully open System Pump Must be wired direct to boiler Remove exist links X V0H HTG Zone Valve nd Switch Close on fully open X6 0v Power Supply 0v amp Switched Spur Boiler AOVW00 7

28 AVATA v/8v/v System Only Option Simple weather compensated Heating with Priority 8

29 AVATA v/ 8v/v System Only Option Simple weather compensated Heating with 0v room thermostat override and Priority 9

30 AVATA v/8v/vsystem Only Option 6 Simple weather compensated Heating with volt free room thermostat override and Priority 0

31

32 The schematics in this brochure are for guidance only and do not constitute a design. The content in this brochure is based on the latest information available at date of publication and may be subject to revisions. We reserve the right to continuous development in both design and manufacture, therefore any changes to the technology or equipment employed may not be retrospective nor may we be obliged to adjust earlier supplies accordingly. Broag td. Remeha House Molly Millars ane RG QP WOKIGHAM, Berks. Copyright All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions furnished by us remain our property and may not be multiplied without our prior consent in writing. Tel: Fax: Internet: uk.remeha.com -mail: boilers@broag-remeha.com

Installation & Service Manual Remeha Avanta Range. 24c 28c 35c 39c 18s 24s 30s

Installation & Service Manual Remeha Avanta Range. 24c 28c 35c 39c 18s 24s 30s Installation & Service Manual Remeha Avanta Range 24c 28c 35c 39c 18s 24s 30s Remeha Avanta Plus Benchmark places responsibilities on both manufacturers and installers. The purpose is to ensure that customers

More information

Remeha Avanta Plus. Remeha Avanta Plus. Installation and service manual. Remeha Avanta Plus 28c. Remeha Avanta Plus 35c. Remeha Avanta Plus 39c

Remeha Avanta Plus. Remeha Avanta Plus. Installation and service manual. Remeha Avanta Plus 28c. Remeha Avanta Plus 35c. Remeha Avanta Plus 39c Installation and service manual Remeha Avanta Plus Remeha Avanta Plus Remeha Avanta Plus 28c Remeha Avanta Plus 35c Remeha Avanta Plus 39c Remeha Avanta Plus 24s 1 Remeha Avanta Plus INTRODUCTION 1 SAFETY

More information

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission The New Remeha Quinta Pro Range Condensing Boilers REMEHA QUINTA PRO RANGE HIGH EFFICIENCY 110% NCV AT 40/30 C FULLY MODULATING BOILER CONTROL PREMIX BURNER CLEAN COMBUSTION ULTRA LOW NOx BREEAM EXCELLENT

More information

isense This could be the smartest room thermostat you ve ever used

isense This could be the smartest room thermostat you ve ever used isense This could be the smartest room thermostat you ve ever used isense This could be the smartest room thermostat you ve ever used With the isense, Remeha sets a new standard for a comfortable atmosphere

More information

The New Remeha Quinta Pro Selection, Design and Installation of Flue Systems

The New Remeha Quinta Pro Selection, Design and Installation of Flue Systems The New Remeha Quinta Pro Selection, Design and Installation of Flue Systems HIGH EFFICIENCY 110% NCV AT 40/30 C FULLY MODULATING BOILER CONTROL PREMIX BURNER CLEAN COMBUSTION ULTRA LOW NOx BREEAM EXCELLENT

More information

WELCOME TO REMEHA, THE EXPERT CHOICE REMEHA QUINTA RANGE FEATURES AND BENEFITS

WELCOME TO REMEHA, THE EXPERT CHOICE REMEHA QUINTA RANGE FEATURES AND BENEFITS QUINTA RANGE WHAT S INSIDE 03 WELCOME TO REMEHA 03 REMEHA QUINTA RANGE 04 BOILER CONSTRUCTION 07 OPERATING PRINCIPLE 08 TECHNICAL INFORMATION 10 ENGINEERING SPECIFICATION 12 DIMENSIONS AND CONNECTIONS

More information

Remeha Avanta 18v. R e m e h a A v a n t a 1 8 v. Installation and service manual. Wall hung high-efficiency. condensing boiler

Remeha Avanta 18v. R e m e h a A v a n t a 1 8 v. Installation and service manual. Wall hung high-efficiency. condensing boiler Installation and service manual Remeha Avanta 8v R e m e h a A v a n t a 8 v Wall hung high-efficiency condensing boiler for open vented systems Output 9 kw Remeha Avanta 8v TABE OF COTETS ITRODUCTIO SAFETY.

More information

Avanta 24c - 28c - 35c - 39c 18s - 24s - 30s

Avanta 24c - 28c - 35c - 39c 18s - 24s - 30s Great Britain EN High-efficiency wall-hung boilers Avanta 24c - 28c - 35c - 39c 18s - 24s - 30s User s Operation Instructions & Important Warranty Information Please keep these instructions in a safe place.

More information

Avanta 12v - 15v - 18v - 24v - 30v

Avanta 12v - 15v - 18v - 24v - 30v Great Britain EN High-efficiency wall-hung boilers Avanta 12v - 15v - 18v - 24v - 30v User s Operation Instructions & Important Warranty Information. Please keep these instructions in a safe place. If

More information

User s Operation Instructions & Important Warranty Information. High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h

User s Operation Instructions & Important Warranty Information. High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h United Kingdom en User s Operation Instructions & Important Warranty Information High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h Please keep these instructions in a safe place.

More information

R e m e h a P Technical Information. Remeha P 300. Pressurized boiler. Heat output: kw

R e m e h a P Technical Information. Remeha P 300. Pressurized boiler. Heat output: kw Technical Information Remeha P 300 R e m e h a P 3 0 0 Pressurized boiler Heat output: 278-709 kw Remeha P 300 CONTENTS Preface 3 1 Description of the unit 3 1.1 General 3 1.2 Burners 3 2 Construction

More information

User s Operation Instructions & Important Warranty Information

User s Operation Instructions & Important Warranty Information United Kingdom en User s Operation Instructions & Important Warranty Information High-efficiency wall-hung boilers Baxi Avanta Plus 18s - 24s - 30s 24c - 28c - 35c - 39c Please keep these instructions

More information

Electronic Dual Cylinder Thermostat Installation Instructions

Electronic Dual Cylinder Thermostat Installation Instructions ESCTDEB Electronic Dual Cylinder Thermostat Installation Instructions Thank you for choosing ESi Controls. All our products are tested in the UK so we are confident this product will reach you in perfect

More information

Technical information. Remeha P 500. Pressurized boiler. Heat output: kw

Technical information. Remeha P 500. Pressurized boiler. Heat output: kw Technical information Remeha P 500 R e m e h a P 5 0 0 Pressurized boiler Heat output: 635-1900 kw Remeha P 500 TABLE OF CONTENT Preface 3 1 Description of the unit 3 1.1 General 3 1.2 Burners 3 2 Construction

More information

Format System 25 HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Format System 25 HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty UK ENSURE THAT THESE INSTRUCTIONS ARE LEFT FOR THE USER AFTER COMPLETION OF THE BENCHMARK SECTION Format System 25 HE User instructions 199838 Please read the Important Notice within this guide regarding

More information

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions GB PLEASE LEAVE THIS INSTRUCTION WH THE USER ECOMFORT PLUS 25 HE User instructions All descriptions and illustrations provided in this manual have been carefully prepared but we reserve the right to make

More information

Direct Sales Tel: Fax: Technical Information Tel: Fax:

Direct Sales Tel: Fax: Technical Information Tel: Fax: PAGE 16 REMEHA AVANTA PRODUCT RANGE 2010 Install Avanta boilers and collect Remeha Diamond Club Points From now on, you will be able to register every boiler you purchase and receive Diamond Points to

More information

CET2000B-RF + RX1-S + CS2

CET2000B-RF + RX1-S + CS2 + RX1-S + CS2 Wireless Electronic Hot Water Cylinder Thermostat Danfoss Heating Installation Guide For a large print version of these instructions please call Marketing on 0845 121 7400. Hearby, Danfoss

More information

A /13

A /13 DRAWING DETAILS PART NUMBER REV ECO 50040745-201 A 0104955 11/13 ARTWORK DESCRIPTION DRAWN MKTING DATE evohome Installation Guide booklet (EN) MF AH 11/13 BOOKLET DETAILS SPECIFICATION COVER INNER PAGES

More information

Home. Wiring Guide. Issue 17

Home. Wiring Guide. Issue 17 Home Wiring Guide Issue 17 Contents Section Title Page Introduction /Contact us/wiring otes 3-4 Wiring plans Sundial S Plan 5-7 Sundial S Plan Plus 8 Sundial Y Plan 9-11 Sundial C Plan 12-13 Sundial C

More information

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION 0 RD 0 RI 0000-06 IM/ IM/a INSTALLATION MANUAL This manual gives detailed advice for installation and should be read carefully prior to fitting

More information

Home. evohome WiFi MULTI-ZONE SYSTEM

Home. evohome WiFi MULTI-ZONE SYSTEM Home evohome WiFi MULTI-ZONE SYSTEM evohome is a sophisticated heating system that ensures you can create and individually control up to 12 heating zones in domestic properties. evohome will also control

More information

Digital Thermostat Models: VS30W and VS30B

Digital Thermostat Models: VS30W and VS30B it600 VS30W - VS30B Installer - User Manual 015_Layout 1 28.07.2014 10:28 Digital Thermostat Models: VS30W and VS30B INSTALLER / USER MANUAL it600 VS30W - VS30B Installer - User Manual 015_Layout 1 28.07.2014

More information

evohome controls evohome consists of a number of quality components manufactured by the UK s leading manufacturer of home heating controls.

evohome controls evohome consists of a number of quality components manufactured by the UK s leading manufacturer of home heating controls. evohome controls evohome consists of a number of quality components manufactured by the UK s leading manufacturer of home heating controls. Radiator controllers The radiator controllers use two-way communication

More information

WELCOME TO REMEHA, THE EXPERT CHOICE REMEHA QUINTA RANGE FEATURES AND BENEFITS

WELCOME TO REMEHA, THE EXPERT CHOICE REMEHA QUINTA RANGE FEATURES AND BENEFITS QUINTA RANGE WHAT S INSIDE 03 WELCOME TO REMEHA 03 REMEHA QUINTA RANGE 04 BOILER CONSTRUCTION 07 OPERATING PRINCIPLE 08 TECHNICAL INFORMATION 10 ENGINEERING SPECIFICATION 12 DIMENSIONS AND CONNECTIONS

More information

Technical information. Remeha P200. Pressurized boiler. Heat output: kw

Technical information. Remeha P200. Pressurized boiler. Heat output: kw Technical information Remeha P200 R e m e h a P 2 0 0 Pressurized boiler Heat output: 59-256 kw Remeha P 200 CONTENTS Preface 3 1. Description of the unit 4 1.1 General 4 1.2 Burners 4 2. Construction

More information

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION SOLARCYL IM/SC INSTALLATION MANUAL This manual gives detailed advice for installation and should be read carefully prior to fitting any unvented

More information

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw Superior A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler Outputs 120, 160, 200, 240, 280 kw 1 The Superior is a, pre-assembled floor standing, gas fired high efficiency

More information

ES3247B. 3 Channel Programmer. User and Installation Instructions

ES3247B. 3 Channel Programmer. User and Installation Instructions ES3247B 3 Channel Programmer User and Installation Instructions INDEX User Instructions What is a Channel Programmer? 1 Introduction to the 3 Channel Programmer 2 Quick Operating Guide 3 Programming the

More information

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions GB PLEASE LEAVE THIS INSTRUCTION WITH THE USER Ecomfort 30 HE User instructions CONTENTS OPERATING INSTRUCTIONS FOR THE USER 1.1 INTRODUCTION.................................................................................

More information

evohome multi-zone system evohome

evohome multi-zone system evohome evohome evohome multi-zone system evohome is a sophisticated heating system that ensures you can create and individually control up to 12 heating zones in domestic properties. evohome will also control

More information

4 in 1 Digital Thermostat Control

4 in 1 Digital Thermostat Control 4 in 1 Digital Thermostat Control Models: VS10W and VS10B INSTALLER / USER MANUAL Contents Contents Box contents Introduction Product Compliance System options overview Installation Parameter Settings

More information

Cylinder Manual. Open Vented Cylinders Stainless Steel Water Heaters. Twin Coil TW180V TW210V TW250V TW300V Triple Coil TR250V TR300V

Cylinder Manual. Open Vented Cylinders Stainless Steel Water Heaters. Twin Coil TW180V TW210V TW250V TW300V Triple Coil TR250V TR300V Cylinder Manual Incorporating: User Instructions Installation Instructions Guarantee Registration Open Vented Cylinders Stainless Steel Water Heaters Products covered by this manual: Twin Coil TW180V TW10V

More information

Digital Thermostat. Models: VS35W and VS35B INSTALLER / USER MANUAL

Digital Thermostat. Models: VS35W and VS35B INSTALLER / USER MANUAL Digital Thermostat Models: VS35W and VS35B INSTALLER / USER MANUAL Contents Contents Box Contents Introduction Product Compliance Installation User Guide Parameter Settings Installers Notes Warranty Icons

More information

System Installation. multi-zone heating

System Installation. multi-zone heating System Installation multi-zone heating Table of contents INTRODUCTION 1 Instructions guidance... 2 1.1 Product documentation...2 1.2 Associated documents...2 1.3 Explanation of symbols...2 1.4 Guarantee

More information

Contents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual:

Contents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual: Contents Box contents: Instruction Manual Instruction manual: Box contents Introduction Product compliance System options overview Installation Parameter settings Error codes User guide Installers notes

More information

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat. ROOM THERMOSTAT SYSTEM Radio frequency controlled programmable room thermostat. LARGE RECEIVER: 24CDi, 26CDi Xtra, 28CDi, 35CDi Mk I and 35CDi Mk II SMALL RECEIVER: 24i Junior, 28i Junior and Si Mk II

More information

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM Radio frequency controlled programmable room thermostat FOR GREENSTAR 25 HE and GREENSTAR 30 HE MODELS Hol Man Auto Day SIGNAL HEATING ON OVERRIDE

More information

Broag Pressurisation equipment

Broag Pressurisation equipment Broag Pressurisation equipment Compact wall mounted and free standing pressurisation units, utilising the latest microprocessor control. For use on sealed heating and cooling systems, offering accurate

More information

RVL480. Heating Controller

RVL480. Heating Controller 2 540 Heating Controller RVL480 Multifunctional and communicating heating controller for use in residential and non-residential buildings. Suited for heating circuit control, boiler temperature control

More information

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - TriMax prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

Installation guide. Wireless room thermostat with hot water control (DHW & single zone CH)

Installation guide. Wireless room thermostat with hot water control (DHW & single zone CH) Installation guide Wireless room thermostat with hot water control (DHW & single zone CH) Logic Heat H / Logic Max Heat H / Logic System S / Logic Max System S / Vogue System / Vogue Max System Ideal Touch

More information

evohome Sundial pack Thermostat

evohome Sundial pack Thermostat evohome Sundial pack Thermostat Installation Overview Honeywell is providing two pre-configured packs: Sundial pack and evotouch Thermostat. evohome Sundial pack This pack is suitable for S plan and Y

More information

Logic+ Combi

Logic+ Combi USER GUIDE Logic+ Combi 24 30 35 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use

More information

Pressurisation units & expansion vessels

Pressurisation units & expansion vessels Pressurisation units & expansion vessels Pressurisation units The new generation of microprocessor controlled pressurisation units Standard Unit/Advanced Unit These microprocessor controlled pressurisation

More information

ir-range 8G /03.15 Changes reserved.

ir-range 8G /03.15 Changes reserved. U s e r m a n u a l ic-range is-range ir-range 8G.52.80.00/03.15 Changes reserved. Contents 1. Introduction...3 2. Safety...5 3. Boiler description...6 4. Display and functions...7 4.1 DHW and Heating

More information

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r. Ultracom hxi High Efficiency Condensing System Boilers Instructions for Use To b e l e f t w i t h t h e u s e r WARNING GAS LEAK OR FAULT Turn off the gas emergency control valve immediately. Eliminate

More information

RVL481. Heating Controller. including d.h.w. heating

RVL481. Heating Controller. including d.h.w. heating 2 541 Heating Controller including d.h.w. heating RVL481 Multifunctional and communicating heating controller for use in residential and non-residential buildings. Suited for heating circuit control with

More information

Nu-Heat UNDERFLOOR & RENEWABLES

Nu-Heat UNDERFLOOR & RENEWABLES Nu-Heat UNDERFLOOR & RENEWABLES warm water underfloor heating with a heat pump electrical manual design innovation expertise service v2a-may v1-mar 08 07 Nu-Heat Title Section Contents Introduction Systems

More information

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - TriMax prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

WLM3 the 3 rd generation of the OJ Waterline TM Control Systems. Industry leading intelligence, control SLIDE OJ Electronics

WLM3 the 3 rd generation of the OJ Waterline TM Control Systems. Industry leading intelligence, control SLIDE OJ Electronics WLM3 the 3 rd generation of the OJ Waterline TM Control Systems Industry leading intelligence, control and operation SLIDE 1 Designed to deliver value for all. Benefits; Reliability - Fit and Forget Flexibility

More information

MURELLE EV HE 25/55-30/55

MURELLE EV HE 25/55-30/55 UK ENSURE THAT THESE INSTRUCTIONS ARE LEFT FOR THE USER AFTER COMPLETION OF THE BENCHMARK SECTION MURELLE EV HE 25/55-30/55 User instructions 199838 Please read the Important Notice within this guide regarding

More information

Control Packs Catalogue. Including control packs compliant with 2013 Building Regulations: Part L

Control Packs Catalogue. Including control packs compliant with 2013 Building Regulations: Part L Control Packs Catalogue Including control packs compliant with 2013 Building Regulations: Part 1 Danfoss imited Ampthill Road Bedford MK42 9ER Reception Tel: 01234 364621 Fax: 01234 219705 UK Sales Tel:

More information

UK arotherm Schematics and installation guide

UK arotherm Schematics and installation guide UK arotherm Schematics and installation guide Air to Water Heat Pumps (AWHP) Controls: VRC 700, VR 70, VR 91 The Vaillant heat pump booklet contains documentation to assist in the design, installation

More information

Operating Instructions

Operating Instructions Operating Instructions Model : PRT-E / PRT-EN Installer Note: This thermostat is a combination model allowing you to choose between Floor Only or Air & Floor temperature control. Please see page 11 for

More information

Installation & User s Instructions

Installation & User s Instructions Installation & User s Instructions 8 080 shown Part No. 00 day Wired Digital Programmer & Room Sensor Part No. 080 day Wireless Digital Programmer & Room Sensor Part No. 00 hr Wireless Digital Programmer

More information

USERS GUIDE. LOGIC+ Combi 24, 30, 35

USERS GUIDE. LOGIC+ Combi 24, 30, 35 USERS GUIDE LOGIC+ Combi 24, 30, 35 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use

More information

MERIDIAN HE 30 C. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

MERIDIAN HE 30 C. User instructions. Please read the Important Notice within this guide regarding your boiler warranty UK ENSURE THAT THESE INSTRUCTIONS ARE LEFT FOR THE USER AFTER COMPLETION OF THE BENCHMARK SECTION MERIDIAN HE 30 C 199838 User instructions Please read the Important Notice within this guide regarding

More information

Installation and Instructions for Use Outdoor Sensor

Installation and Instructions for Use Outdoor Sensor Installation and Instructions for Use Outdoor Sensor To b e l e f t w i t h t h e u s e r General Customer Service: 01773 828100 Technical Helpline: 01773 828300 General and Sales enquiries: Tel. 01773

More information

WEATHER COMPENSATION KIT

WEATHER COMPENSATION KIT WEATHER COMPESATIO KIT When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned

More information

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for vented systems.

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for vented systems. ECONOPLATE H1-heat only HEAT INTERFACE UNIT Installation, Commissioning and Servicing Instructions for vented systems. Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING,

More information

Tristor MF. Installation Guide

Tristor MF. Installation Guide Tristor MF Installation Guide Tel 1952 257963 Fax 1952 253452 Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE www.telford-group.com NOV 24 Parts Installer Replaced Registration

More information

the electric heating company ELECTRIC BOILER HANDBOOK

the electric heating company ELECTRIC BOILER HANDBOOK the electric heating company ELECTRIC BOILER HANDBOOK About Us Innovative heating and hot water specialists, The Electric Heating Company, have developed their product portfolio to accommodate almost any

More information

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty UK ENSURE THAT THESE INSTRUCTIONS ARE LEFT FOR THE USER AFTER COMPLETION OF THE BENCHMARK SECTION FORMAT DGT HE 199838 User instructions Please read the Important Notice within this guide regarding your

More information

Remeha Quinta 45 and 65

Remeha Quinta 45 and 65 Technical information Remeha Quinta 45 and 65 Remeha Quinta 45/65 High-efficiency condensing boiler for wall mounted installation Output Quinta 45 : Quinta 65 : 9-43 kw 13-65 kw 1 TABLE OF CONTENTS Preface

More information

Remeha Quinta 85. Technical information. Remeha Quinta 85. High-efficiency. condensing boiler for wall. mounted installation.

Remeha Quinta 85. Technical information. Remeha Quinta 85. High-efficiency. condensing boiler for wall. mounted installation. Technical information Remeha Quinta 85 Remeha Quinta 85 High-efficiency condensing boiler for wall mounted installation Output: 14-90 kw TABLE OF CONTENT Preface 5 1 General description of the boiler 6

More information

Maincor Air Temperature Controls AIR TEMPERATURE CONTROL

Maincor Air Temperature Controls AIR TEMPERATURE CONTROL AIR TEMPERATURE CONTROL Overview In multi-zone systems, a thermostat is positioned in the room which is being heated and is set to the required temperature. Once the room gets up to the pre-set temperature,

More information

MEGAFLO HE Iss 1

MEGAFLO HE Iss 1 MEGAFLO HE 1 36 00 5843 Iss 1 Contents Contents SECTION PAGE 1 INTRODUCTION... 3 2 GENERAL REQUIREMENTS... 4 3 INSTALLATION - GENERAL... 5 4 INSTALLATION - DIRECT UNITS... 8 5 INSTALLATION - INDIRECT UNITS...

More information

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r. Ultracom cxi High Efficiency Condensing System Boilers Instructions for Use To b e l e f t w i t h t h e u s e r WARNING GAS LEAK OR FAULT Turn off the gas emergency control valve immediately. Eliminate

More information

Remeha Quinta 30. Technical information. High-efficiency. condensing boiler for. wall mounted. installation. Output: kw

Remeha Quinta 30. Technical information. High-efficiency. condensing boiler for. wall mounted. installation. Output: kw Technical information Remeha Quinta 30 R e m e h a Q u i n t a 3 0 High-efficiency condensing boiler for wall mounted installation Output: 5.6-28 kw 1 Remeha Quinta 30 TABLE OF CONTENT Preface 5 1 General

More information

ADVANCE ECB ELECTRIC COMBINATION BOILER

ADVANCE ECB ELECTRIC COMBINATION BOILER ISSUE ISSUE 45 0115 0317 INSTALLATION AND USER GUIDE ADVANCE ECB ELECTRIC COMBINATION BOILER ADVANCE APPLIANCES LTD HOUSEHOLDER - PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE 1 SCHEMATIC

More information

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent CLAS HE WALL-HUNG HIGH EFFICIENCY GAS BOILERS Elegant, efficient and intelligent The high efficiency boiler that saves on energy and costs With specified intelligence, CLAS HE adapts to the householder's

More information

Installation Guide Single Zone Thermostat Y87RF

Installation Guide Single Zone Thermostat Y87RF Installation Guide Single Zone Thermostat Y87RF Installation instructions 1. Disconnect the mains power from the Heating Appliance. To ensure your safety, always make sure mains power is switched off before

More information

Honeywell Homes T3, T3M & T3R

Honeywell Homes T3, T3M & T3R Honeywell Homes T3, T3M & T3R PRODUCT SPECIFICATION SHEET Honeywell T3 & T3M Programmable Thermostat Honeywell T3R Programmable Thermostat The T3, T3M & T3R thermostats are designed to provide automatic

More information

THE REMEHA HIU RANGE Installation, operation and maintenance manual December 2017

THE REMEHA HIU RANGE Installation, operation and maintenance manual December 2017 Installation, operation and maintenance manual December 2017 CONTENTS The following instructions are for the E70/5, E70/9, T60/5 & T60/7. Introduction... 3 Declaration of conformity... 3 Symbol key...

More information

CM907- TRV PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CM907- TRV PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET CM907- TRV PROGRAMMABLE THERMOSTAT PRODUCT SPECIFICATION SHEET FEATURES Attractive, slim, ultra-modern styling makes it ideal for location in any type of home. 7-day heating program. A dynamic text display

More information

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for unvented systems.

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for unvented systems. ECONOPLATE H1-heat only HEAT INTERFACE UNIT Installation, Commissioning and Servicing Instructions for unvented systems. Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING,

More information

heat interface units A BOILER WITHOUT A FLAME

heat interface units A BOILER WITHOUT A FLAME A BOILER WITHOUT A FLAME heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment in the building.

More information

Wired Solutions Wired Heating Control Products

Wired Solutions Wired Heating Control Products Wired Solutions Wired Heating Control Products Timeswitches & Programmers Programmable Thermostats Thermostats & Frost Thermostats Motorised Zone Valves Cylinder Thermostats Surface Mount & Immersion Thermostats

More information

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers 5 YEAR WARRANTY ADVANCE PLUS High efficiency condensing combi and system boilers Android Apple WALL HUNG BOILERS Advance Plus ADVANCE PLUS HIGH EFFICIENCY BOILER RANGE The Advance Plus range is the latest

More information

Sirius FS. Working towards a cleaner future

Sirius FS. Working towards a cleaner future Sirius FS Floor Standing Stainless Steel Condensing Boilers Single Boiler Applications: 50 to 160kW Modular Boiler Applications: up to 640kW Working towards a cleaner future heating specialists 1. Product

More information

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw 90 kw Clyde Alkon 90 LP Gas Floor standing condensing boilers Natural Gas 90 kw Contents General information Dimensions and Data Installation requirements Boiler wiring diagram Hydraulic systems Page Fully

More information

FRONT COVER (TOP) OUTLET WARNING LABEL RED IDENT ELECTRICAL CABLE ENTRY POINTS EARTH CLAMP INSULATION SHEET TERMINAL BLOCK FLYING LEAD MAIN PCB

FRONT COVER (TOP) OUTLET WARNING LABEL RED IDENT ELECTRICAL CABLE ENTRY POINTS EARTH CLAMP INSULATION SHEET TERMINAL BLOCK FLYING LEAD MAIN PCB Models: 95 022 001 C-400 GC No.EB-205-06 95 022 002 C-600 GC No.EB-205-02 95 022 003 C-900 GC No.EB-205-03 95 022 004 C-1100 GC No.EB-205-01 95 022 005 C-1200 GC No.EB-205-04 95 022 101 U-401 GC No.EB-205-08

More information

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring Page 1 of 8 IMAGINATION SOLAR LTD Installation Guide B1 Planning the Plumbing and Wiring Unit 4 Montpelier Central, Station Road Bristol BS6 5EE t: 0117 942 6668 f: 0117 942 8998 e: enquiries@imaginationsolar.com

More information

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40 USER GUIDE VOGUE COMBI GEN2 C26 C32 C40 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not

More information

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Ambient temperature This is the air temperature within a 21 ºC room at any given time. It depends

More information

Atmos EasySolar. Installation Instructions for. In-roof and flat roof installation with flat plate collectors

Atmos EasySolar. Installation Instructions for. In-roof and flat roof installation with flat plate collectors Atmos EasySolar Installation Instructions for Atmos EasySolar In-roof and flat roof installation with flat plate collectors Atmos Heating Systems West March Daventry Northants, NN11 4SA Tel: 01327 871990

More information

Grohtherm Wireless! Installation Instructions Pumped High Pressure

Grohtherm Wireless! Installation Instructions Pumped High Pressure 36 022 Pumped Grohtherm Wireless! 36 023 High Pressure Grohtherm Wireless! GB D...1...5 I...5 N...9 GR...13 TR...17 BG...21 RO...25 GB...2 NL...6 FIN...10 CZ...14 SK...18 EST...22 RUS...26 Installation

More information

Quartz. Digital. Bath with bath waste filler. Quartz Digital Bath with bath waste filler installation instuctions page 1

Quartz. Digital. Bath with bath waste filler. Quartz Digital Bath with bath waste filler installation instuctions page 1 Quartz Digital Bath with bath waste filler The Waste Electrical and Electronic Equipment (Producer Responsibility) Regulation 2004 This product is outside the scope of the European Waste Electrical and

More information

WALL-HUNG HIGH EFFICIENCY GAS BOILERS

WALL-HUNG HIGH EFFICIENCY GAS BOILERS Heating Hot water Renewables GAS BOILERS E-COMBIevo E-SYSTEMevo CLAS HEevo CLAS HEevo system CLAS HE R WALL-HUNG HIGH EFFICIENCY GAS BOILERS Ariston a tradition that evolves For many years, we have entered

More information

Fingertip control, optimum efficiency, total comfort and clear reporting. warmafloor.co.uk

Fingertip control, optimum efficiency, total comfort and clear reporting. warmafloor.co.uk Fingertip control, optimum efficiency, total comfort and clear reporting warmafloor.co.uk 1 Contents Intelligent control. 3 The key to efficiency Key system features 4 and benefits 7 Touchscreen 5 Alarms

More information

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO Great Britain en Installation, user and service manual Control panel HMI Gas 310/610 ECO PRO Dear Customer, Thank you very much for buying this appliance. Please read through the manual carefully before

More information

Heating Controls Technical

Heating Controls Technical 472 Room Thermostat Voltage Rating: 230V AC 50Hz Switch Rating: Terminal 3 10A resistive, 3A inductive Terminal 4 6A resistive, 2A inductive Single pole, double throw (SPDT) Temperature Setting Range:

More information

103E5. Installation & User Instructions. Electronic timeswitch for controlling hot water and heating. including Factory Replacement Units (FRU)

103E5. Installation & User Instructions. Electronic timeswitch for controlling hot water and heating. including Factory Replacement Units (FRU) 103E5 Electronic timeswitch for controlling hot water and heating Installation & User Instructions including Factory Replacement Units (FRU) Certification Mark This product complies with the following

More information

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control. Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA 02717 The first totally integrated multiple boiler management control. USING THIS MANUAL USING THIS MANUAL A. INSTALLATION SEQUENCE Follow

More information

Fusion 200, 300 & 500

Fusion 200, 300 & 500 Fusion 200, 300 & 500 Installation and Operating Manual Issue 07/07 Part of The Mikrofill Group Contents 1 Fusion 2 1.1. Safety Provisions 3 1.2. Delivery 3 1.3. Hydraulic system Diagram 3 1.4. 2 Fusions

More information

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses INSPIRED H I G H H O T EF F ICIENCY E F F I C I E N C Y W A T E R S Y S T E M S E XT REME HIGH EFFICIENCY HO T W AT ER SY ST EMS w i th I N JECT I O N DYN A M I C S T ECHN I CAL DO CUME N TA T I O N I

More information

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC Viega Zone Control Applications The Viega Zone Control is a wiring and switching center for individual and / or multi- room control. The Zone Control simplifies wiring between Thermostats and Powerheads.

More information

Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013

Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013 Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013 Calorifiers Heat Exchangers Pressurisation Units Sales Tel: 01457 835700 Sales Fax: 01457 832700 E-mail:

More information