Refrigeration Training System
|
|
- Reynard Hubbard
- 6 years ago
- Views:
Transcription
1 Refrigeration Training System LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 04/2018
2 Table of Contents General Description 2 Topic Coverage 2 Features & Benefits 2 List of Manuals 3 Table of Contents of the Manual(s) 3 Additional Equipment Required to Perform the Exercises 3 Optional Equipment 3 Optional Manual(s) 4 Specifications 4 Module Options Description 5 General Description The Refrigeration Training System is an integrated training system that introduces students to the principles and components of a refrigeration system using industrial and commercial devices. The training system clearly demonstrates the operation of the most common refrigeration system configurations, including dual evaporator systems. Lockable fault-insertion switches allow students to practice troubleshooting skills, which may be conducted at either the schematic control panel or at the suspect devices and components. Fully integrated courseware guides students through alternative modes of system set-up and control. The training system includes all the equipment required to perform the exercises contained in the courseware. Optional equipment adds to the efficiency of the refrigeration, air conditioning, and heating training laboratories. The Refrigeration Training System is supported by correlated courseware employing a competency-based, individualized approach to the study of intermediate refrigeration topics. The courseware consists of a training manual organized in a unit/exercise format with clearly stated objectives. Topic Coverage Introduction to the System Trainer Setup Receiver, Accumulators, Oil Separators Compressor Operation of Metering Devices System Control Services Evaporator and Condenser Principles Refrigeration Systems Variations of System Loading System Troubleshooting Features & Benefits Two forced-air evaporator coils operating individually, in series, or in parallel, enclosed in chambers with clear acrylic windows Variable-speed fans and adjustable damper to simulate changing environmental conditions Schematic panel with multicolored electrical and tubing schematics, as well as indicator lamps and functional duplication of test points Lockable fault-insertion switches to introduce 18 distinct electrical faults 2 Festo Didactic
3 Heavy-duty steel mobile stand with heavy-duty casters Instrumentation including: temperature, watt, volt, and ampere meters, as well as pressure gauges Circuit breakers and safety pressure switch to protect the system R-134a refrigerant Estimated program duration: 65 hours List of Manuals Manual Description Refrigeration Systems and Controls (Student Manual) Refrigeration Systems and Controls (Instructor Guide) Refrigeration System Setup (User Guide) E0 Table of Contents of the Manual(s) Refrigeration Systems and Controls (Student Manual) ( ) 1-1 System Control Panels 1-2 System Configuration 2-1 Liquid Receiver 2-2 Suction Line Accumulator 2-3 Oil Separator 3-1 Types of Compressors 3-2 Operation of the Compressor 3-3 Compressor Test Equipment 4-1 Thermostatic Expansion Valve 4-2 Automatic Expansion Valve 4-3 Capillary Tube 5-1 Pressure Controllers 5-2 Thermostatic Controls 5-3 Solenoid Valve Controls 5-4 Back Pressure Regulator 6-1 Superheating and Subcooling 6-2 Heat Exchanger 7-1 Evaporators in Parallel 7-2 Dual Thermostatic Controls 7-3 Complex Refrigeration System 8-1 Heat Loading with Capillary Tubes 8-2 Heat Loading with Thermostatic Expansion Valves 9-1 Compressor, Pressure Controller, and Evaporator Fan Faults 9-2 Thermostatic Controller and Condenser Fan Faults 9-3 Unknown Faults Additional Equipment Required to Perform the Exercises Model Qty Description 1 1 Training on Refrigeration Systems and Controls, 1.1 days TF Optional Equipment 1 Optional product training. Price provided on demand. For details and options, contact services.didactic@festo.com. Festo Didactic 3
4 Qty Description Model 1 Refrigeration Charging Equipment Vizi-Vapor Charging Accessory Refrigerant Recovery Unit Optional Manual(s) Model Qty Description 1 Manuals on CD-ROM Refrigeration Training System (Student Manual) A0 Specifications Parameter Power Requirements Current Service Installation Compressor Type Nominal Power Refrigerant Evaporator Condenser Control Devices Instrumentation Auxiliary Equipment Value 13 A Standard single-phase ac outlet Semi-hermetic 373 W (0.5 hp) R134-a. The help of a refrigeration technican is required to fill the training system with refrigerant. 2 forced-air coils, enclosed in separate chambers, with variable-speed fans. May be operated individually, in series, or in parallel. 1 forced-air coil with variable-speed fan. High-pressure switch Low-pressure switch Thermostatic expansion valve Back-pressure regulator Capillary tube Automatic expansion valve Solenoid valves Thermostatic controllers Temperature meter Watt meter Volt and ampere meters Pressure gauges Indicator lamps Liquid receiver Suction accumulator Filter dryer Oil separator Manual valves Heat exchanger 4 Festo Didactic
5 Parameter Protection Fault Insertion Switches Number 18 Physical Characteristics Intended Location Dimensions (H x W x D) Net Weight Value Module Options Description Refrigeration Charging Equipment Features & Benefits Safety pressure switch Mains and compressor breaker switch On the floor (stands on casters) 1900 x 2200 x 800 mm (74.8 x 86.6 x 31.5 in) 281 kg (619.5 lb) Easy-to-read gauges Forged-brass body with metal valve handles Color-coded hoses Hose cover pin-pricked to resist bubbling and bursting Two-stage vacuum pump for great efficiency Refrigerant charging meter automatically shuts off when charging is completed Compatible with refrigerants R-12, R-134a, R-404A, R-502, and R-507 Specifications Parameter Refrigeration Charging Equipment Value Manifold Charging hose kit Vacuum pump Automatic refrigerant charging meter Heater blanket The Refrigeration Charging Equipment is an accessory kit in refrigeration and air conditioning. The Refrigeration Charging Equipment is designed to enable students to evacuate and charge refrigeration training systems. It consists of a manifold, a charging hose kit, a vacuum pump, an automatic refrigerant charging meter, and a heater blanket. Festo Didactic 5
6 Vizi-Vapor Charging Accessory The Vizi-Vapor Charging Accessory is an accessory in refrigeration and air conditioning. It transforms liquid refrigerant into saturated vapor visible in the transparent cylinder. This helps ensuring the system is properly charged. The Vizi-Vapor Charging Accessory requires the Refrigeration Charging Equipment, Model Refrigerant Recovery Unit The Refrigerant Recovery Unit enables students to recover refrigerant for storage or recycling. A low-pressure indicator on the unit monitors the pressure condition on the suction side of the recovery system. A filter dryer and an oil separator are used to condition the refrigerant before it enters the recovery system compressor. At the high-pressure side of the recovery system compressor, a second oil separator ensures good lubrication by returning the oil at the suction side of the compressor, thus avoiding oil migration to the storage tank. A high-pressure indicator is also provided to monitor the pressure conditions on the discharge side of the compressor. A high-pressure controller will automatically shut off the compressor if the discharge pressure exceeds a preset limit. A forcedair condenser is used to transform the high-pressure refrigerant vapor to a high-pressure liquid refrigerant. List of Manuals Manual Description Refrigeration System Setup (User Guide) E0 Refrigerant Recovery Unit (Instruction Manual) D0 Features & Benefits Hermetically sealed compressor Compressor oil drain conveniently located at the bottom of the unit Easy access to filter at the back of the unit, after removal of the access door Forced-air coil condenser 6 Festo Didactic
7 Low-and high-pressure gauges High-pressure safety device Compatible with refrigerants R-134a Specifications Parameter Power Requirements Current Service Installation Compressor Type Nominal Power Oil Condenser Type Refrigerant Compatibility Filter/Dryer Type Instrumentation Safety Device Physical Characteristics Intended Location Required Floor Space (H x W x D) Net Weight Value 2.5 A Standard single-phase ac outlet Hermetically sealed 186 W (1/4 hp) Polyolester, 280 ml (9.5 oz) Forced-air coil R134a 82 ml (5 in³), 6.35 mm (0.25 in) flare x 6.35 mm (0.25 in) flare Low- and high-pressure gauges High pressure On a table able to support the weight of the equipment 345 x 490 x 255 mm (13.6 x 19.3 x 10 in) 50 kg (110 lb) Festo Didactic 7
8 Reflecting the commitment of Festo Didactic to high quality standards in product, design, development, production, installation, and service, our manufacturing and distribution facility has received the ISO 9001 certification. Festo Didactic reserves the right to make product improvements at any time and without notice and is not responsible for typographical errors. Festo Didactic recognizes all product names used herein as trademarks or registered trademarks of their respective holders. Festo Didactic Inc All rights reserved. Festo Didactic SE Rechbergstrasse Denkendorf Germany P. +49(0)711/ F. +49(0)711/ Festo Didactic Inc. 607 Industrial Way West Eatontown, NJ United States P F Festo Didactic Ltée/Ltd 675 rue du Carbone Québec QC G2N 2K7 Canada P F Festo Didactic
3400-3A Refrigeration System Demonstrator
3400-3A Refrigeration System Demonstrator LabVolt Series Datasheet Festo Didactic en 240 V - 50 Hz 04/2018 Table of Contents General Description 2 Topic Coverage 2 Features & Benefits 2 List of Manuals
More informationGeothermal Training System
46126-00 Geothermal Training System LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 05/2018 Table of Contents General Description 2 Geothermal Heat Pump 3 Ground-Loop Heat Exchanger 4 Domestic
More informationGeothermal Training System (46126-A0)
Geothermal Training System 582385 (46126-A0) LabVolt Series Datasheet Festo Didactic en 220 V - 60 Hz 03/2019 Table of Contents General Description 2 Geothermal Heat Pump 3 Ground-Loop Heat Exchanger 4
More information46126-A2 Geothermal Training System
46126-A2 Geothermal Training System LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 04/2018 Table of Contents General Description 2 Geothermal Heat Pump 3 Ground-Loop Heat Exchanger 4 Domestic
More informationLighting and Fire Alarm Training System Add- On ( )
Lighting and Fire Alarm Training System Add- On 588476 (3468-00) LabVolt Series Datasheet Festo Didactic en 11/2018 Table of Contents General Description 2 List of Equipment 2 List of Manuals 2 Table of
More informationMulti-Zone Wireless Control Training Systems ( )
Multi-Zone Wireless Control Training Systems 593306 (3467-00) LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 11/2018 Table of Contents General Description 2 Courseware 2 Topic Coverage 3 List
More informationEDS Solar Thermal ( )
EDS Solar Thermal 8046647 (46121-10) LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 10/2018 Table of Contents General Description 2 Courseware 2 Features & Benefits 3 List of Equipment 3 Manual
More informationRefrigeration System with a Capillary Tube and a Thermostat
Exercise 2-1 Refrigeration System with a Capillary Tube Part A: REFRIGERATION CIRCUIT OBJECTIVE When you have completed this part, a refrigeration circuit using a capillary tube as a metering device will
More informationCUSTOMIZED TEACHER ASSESSMENT BLUEPRINT HVAC MAINTENANCE TECHNOLOGY. Test Code: 5937 Version: 01
CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT HVAC MAINTENANCE TECHNOLOGY Test Code: 5937 Version: 01 Specific competencies and skills tested in this assessment: Introduction to HVAC Identify HVAC systems Demonstrate
More informationThe Refrigeration Cycle
Job Sheet 4 The Refrigeration Cycle OBJECTIVES In this job sheet, you will plot the refrigeration cycle on a pressure-enthalpy diagram using pressures and temperatures measured on your training system.
More informationRefrigeration and Air Conditioning
Refrigeration and Air Conditioning Hampden: The Leader in Real-World Training Hampden Engineering Corporation has been designing and manufacturing educational training devices for engineering, technical,
More informationAir Distribution Systems
Air Distribution Systems Bulletin 227-2B Purpose H-AP-2 Air Distribution System Trainer The Hampden Model H-AP-2 Air Distribution System Trainer is designed to acquaint the student with the fundamentals
More informationMASS. MARITIME ACADEMY
MASS. MARITIME ACADEMY REFRIGERATION LAB OUTLINE Rev.3 Fall 2015 Table of Content Page Lab #1: Introduction to refrigeration system components, tools and procedures 1 Lab #2: Familiarization, operation,
More informationThe Refrigeration Cycle
Job Sheet 4 The Refrigeration Cycle OBJECTIVES In this job sheet, you will plot the refrigeration cycle on a pressure-enthalpy diagram using pressures and temperatures measured on your training system.
More informationCaresaver Universal Refrigerant Recovery Unit
Operation Manual Caresaver Universal Refrigerant Recovery Unit 2 CONTENTS CHAPTER 1 INTRODUCTION AND OVERVIEW Specifications 3 Health and Safety 4-5 Component Location and Identification 6-9 CHAPTER 2
More informationEDUCATIONAL TRAINING UNITS
S OUR COMMITMENT TO QUALITY EDUCATION At Imperial Training we strongly believe in providing the HVAC/R student with the knowledge & training for the safe and efficient operation of all types of systems
More informationJob Sheet 1. Geothermal Energy OBJECTIVES. Familiarization with the training system components PROCEDURE
Job Sheet 1 Geothermal Energy OBJECTIVES In this job sheet, you will become familiar with the training system components. You will operate your training system in heating and cooling mode and observe the
More informationCalhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration
Calhoon MEBA Engineering School Study Guide for Proficiency Testing Refrigeration 1. To prevent an injury when working with refrigerants, what safety precautions are necessary? 2. When halogens are in
More informationResidential Piping and Long Line Guideline
AC / HP R-410A Refrigerant Systems Single-Stage, Two-Stage and Variable Speed Models Residential Piping and Long Line Guideline TABLE OF CONTENTS Safety Considerations... 2 Definitions... 2 Introduction...
More informationENSPECO Recovery/ Recycle/ Evacuate/ Recharge
ENSPECO Recovery/ Recycle/ Evacuate/ Recharge RMS 3012 RMS 3034 Approved by UL/SAE to J-1991 R12 Purity Standards Approved by UL/SAE to J-2210 R134 Purity Standards This semi-automatic machine will recover
More informationOPERATION & MAINTENANCE MANUAL TX600
OPERATION & MAINTENANCE MANUAL TX600 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80118-00 (Rev B) ! TABLE OF CONTENTS! TX600 Before Using Page 2 Safety Precautions Page
More informationCommercial High-Efficiency Condensing Units
FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2
More informationAddressable Fire Alarm System Fire Alarm Training System
Industrial Maintenance Addressable Fire Alarm System Fire Alarm Training System Job Sheets - Courseware Sample 85153-F0 Order no.: 85153-30 First Edition Revision level: 06/2015 By the staff of Festo Didactic
More informationSECTION 50 - CAB CLIMATE CONTROL
AIR CONDITIONING SYSTEM DYNAMIC DESCRIPTION The refrigerant circuit of the air conditioning system contains five major components: Compressor, Condenser, Receiver/Drier, Expansion Valve, and Evaporator.
More information30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw
Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The
More informationcussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION
REFRIGERATION AND AIR CONDITIONING CUSSONS LABORATORY RECOMMENDATION Cussons Refrigeration laboratories are offered to provide teaching to a range of different skill levels. In all the laboratories teaching
More informationUser manual Flushing device VAS 6337/1a
User manual Flushing device VAS 6337/1a 2 Content Safety warnings 3 Flushing with R134a refrigerant 4 1.0 Preparing the Vehicle AC System 4 1.1 Connecting the recovery recharge Unit 6 1.2 Flush procedure
More informationRSES Technical Institute Training Manual 1 70 hours, 70 NATE CEHs, 7.2 CEUs
Lesson 1 - Introduction to Refrigeration and Air Conditioning Define refrigeration. Identify the basic components of a refrigeration cycle. Identify the various gas laws and their importance to a basic
More informationCommercial High-Efficiency Condensing Units
FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON
More informationRefrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24
Refrigeration / Air Conditioning Systems Circuit Drawings Nominal Student Hours: Student Resource Package No: NR 24 24 Hours. Delivery: Recognition of Prior Learning: Package Purpose: Suggested Resources:
More informationRefrigerant Recovery Unit, Model RRU134
Installation, Operation & Maintenance Manual IOMM RRU134 Group: Refrigerant Effective: December 2000 Supersedes: New Refrigerant Recovery Unit, Model RRU134 1999 McQuay International Table of Contents
More informationGrades Prentice Hall. Fundamentals of HVAC/R HVACR High School ISBN's SE / IG Grades 9-12
Prentice Hall Fundamentals of HVAC/R 2010 Grades 9-12 C O R R E L A T E D T O HVACR High School ISBN's 9780132223676 SE / 9780132224055 IG Grades 9-12 A. SAFETY (1) Identify types, purposes, and operation
More informationREFRIGERATION AND AIR CONDITIONING RÉFRIGÉRATION ET CLIMATISATION POST-SECONDARY NIVEAU POSTSECONDAIRE
INSTRUCTIONS AND COMPETITION DETAILS INSTRUCTIONS ET DÉTAILS DU CONCOURS REFRIGERATION AND AIR CONDITIONING RÉFRIGÉRATION ET CLIMATISATION POST-SECONDARY NIVEAU POSTSECONDAIRE 1. Test Project Details This
More informationSERVICE BULLETIN A
1. PLANNING INFORMATION A. Effectivity: Dassault Falcon 10 aircraft which have installed R-134a Upgrade Kit SZ59K-R134 before August 8, 2002. B. Reason: Upgrade kits before August 8, 2002 did not include
More informationhorizontal air discharge outdoor discus condensing unit
CC-HADTB March 2007 (Replaces CC-B-48D, 10/04) CLIMATE CONTROL horizontal air discharge outdoor discus condensing unit Technical Guide CDH Standard & Optional Features CDH Outdoor Discus Condensing Units,
More informationAir-Cooled Condensing Units with Compact Screw Compressors
LK-SCUTB March 2015 Air-Cooled Condensing Units with Compact Screw s Technical Bulletin Models SSV DSV Table of Contents Nomenclature Chart... 2 Introduction... 3 Bitzer TM s... 4 Magnum TM Microprocessor...
More informationCMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N
E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,
More information60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES
60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,
More informationOPER LV Wheeler Way
OPER RATING INSTRUCTIONS LV5 REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 Wheeler Way Langhorne, PA 19047 Ph:(215) 638-8909 9 info@ @nrproducts.com LV5.DOC 9.17.2018 MODEL LV5 REFRIGERANT
More informationAutomotive Air-Conditioning Service Equipment Ariazone 5001HD OPERATOR MANUAL Ariazone 5001HD
Automotive Air-Conditioning Service Equipment Ariazone 5001HD OPERATOR MANUAL Ariazone 5001HD - Automotive A/C Service Station 1 Contents Page 1. Introduction... 3 2. Safety firts... 4 3. Technical Features...
More informationOPERATION & MAINTENANCE MANUAL AC880
OPERATION & MAINTENANCE MANUAL AC880 Refrigerant Handling System Manual P/N 035-80749-00 TABLE OF CONTENTS AC880 Before Using the AC880... 2 Safety Precautions... 2 Using the AC880... 3 Setup... 4 Fill
More informationCMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL
CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years
More informationOperation and Maintenance Manual
Warranty Information Ritchie Engineering guarantees YELLOW JACKET products to be free of defective material and workmanship which could affect the life of the product when used for the purpose for which
More informationRecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual
RecoverX Oil-Filled Hermetic Refrigerant Recovery System Operation and Maintenance Manual Table of Contents Page General Safety Instructions 2-3 System Overview 3 Operating Guide 4 Restart Procedure 4
More informationWineZone Ceiling Mount Ductless Split 15
WineZone Ceiling Mount Ductless Split 15 Requires an HVAC technician to install and charge with R-22 refrigerant. Easy to install. Unit plugs into wall outlet. Industrial grade unit for longer life. Indoor
More informationThomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.
Thomas J Kelly Sr. Engineering Instructor Carrier Corporation August 20, 2003 1 SESSION OBJECTIVES At the conclusion of this session you should be able to: 1. Describe the basics principles of refrigeration
More informationPerformance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2000 Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in
More informationSTACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank
A C P S C STACT Model Designations Model Number: STACT8S6 ST AC T ST = Portable Scroll Chiller AC = Air Cooled WC = Water Cooled T = With Process Tank 8 8 = Model Size* S 6 XP / LT S = Single Refrigeration
More informationOPERATION & MAINTENANCE MANUAL AC860
OPERATION & MAINTENANCE MANUAL AC860 Refrigerant Handling System Manual P/N 035-80913-00 TABLE OF CONTENTS Startup & Safe Operation... 1 Introduction to the AC860... 2 Control Panel... 3 Keypad Functions...
More information100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION
100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest
More informationRSES Technical Institute Training Manual 2 72 hours, 72 NATE CEHs, 7.2 CEUs
Lesson 1 - Trade Tools Explain the importance of using proper tools and test instruments. List the various types of wrenches and describe their use. Describe the proper procedures for bending, flaring,
More information4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions
4201 Lien Rd Madison, WI 53704 TS-140F Revised 09-10 Owner s Manual Therma-Stor III Heat Recovery System Installation, Operation & Service Instructions Read and Save These Instructions Table Of Contents
More informationMechanical Heat Pump R515
P.A.Hilton Ltd Mechanical Heat Pump R515 Above: R515 shown fitted with standard wattmeter Stabilises in minutes allowing many tests to be conducted in a typical laboratory period. Allows a complete refrigerant
More informationElectrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)
Electrical Problems Fuse(s) blow or circuit breaker trips Does the unit use circuit breakers or fuses? Fuse(s) Circuit breakers Are the fuses dual element time delay? Is the circuit breaker HACR rated?
More information347002K/177002K/34900
Service Manual Models: 347002K/177002K 34900/347012K Manifold Block Style Recovery/Recycling/Recharging Unit For R-12 or R-134a Only TABLE OF CONTENTS: Theory of Operation and Safety Precautions... 2 Depressurizing
More informationSECTION 7 AIR CONDITIONING (COOLING) UNIT 41 TROUBLESHOOTING
SECTION 7 AIR CONDITIONING (COOLING) UNIT 41 TROUBLESHOOTING UNIT OBJECTIVES After studying this unit, the reader should be able to Select the correct instruments for checking an air conditioning unit
More informationOPERATION & MAINTENANCE MANUAL RHS680
OPERATION & MAINTENANCE MANUAL RHS680 Refrigerant Handling System 4075 East Market Street York, PA 17402 800-468-2321 tech@rtitech.com Manual P/N 035-80740-00 (Rev 1- May 22, 2001) TABLE OF CONTENTS Startup
More informationCAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel
More informationMAC N-407 Air-Cooled Chiller
MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=
More informationAE Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A
AE4-1392 July 2014 Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A Section TABLE OF CONTENTS Page Safety Safety Instructions...2 Safety Icon Explanation...2 Instructions
More informationProduct Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)
Product Data 38AH024-134 Commercial Air-Cooled Condensing Units 50/60 Hz 20 to 130 Nominal Tons (63 to 390 Nominal kw) a38-4143ef 38AH044-134 These dependable split systems match Carrier s 40RM or 39 Series
More informationContour TM Screw Compressors
Contour TM Screw Compressors Semi-Hermetic Compact Operating Instruction SCH1 High Temp Compressors Form No. 99-77 1. Introduction This series of semi-hermetic compact screw compressors is designed for
More informationTITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F
Temperature Control Units Water & Oil - F Portable Chillers Air & Water-Cooled - 7 F Central Chillers Air & Water-Cooled Packages & Modules - 7 F Pump Tank Stations Chilled or Tower Water - gallons Cooling
More informationUndercounter Refrigerator Operation Manual i.series and Horizon Series
Undercounter Refrigerator Operation Manual i.series and Horizon Series Blood Bank Models i.series: ib105 (Version B) Horizon Series: HB105 (Version B) Laboratory/Pharmacy Models i.series: ilr105 (Version
More informationPACKAGE AIR CONDITIONER
PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior
More informationPART 3 Refrigeration & Air Condition System
PART 3 Refrigeration & Air Condition System ED-5850/5850GL ED-5851/5851GL ED-5852/5852GL ED-5853 ED-5854 ED-5855 ED-5856 ED-5858 ED-5859 BASIC REFRIGERATION SYSTEM BASIC REFRIGERATION & FREEZING SYSTEM
More informationINTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies
Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER
More informationHVACR Refrigeration
Western Technical College 10601101 HVACR Refrigeration Course Outcome Summary Course Information Description Career Cluster Instructional Level Total Credits 4.00 Total Hours 108.00 This course is an introduction
More informationAUTOMOTIVE SPECIALIZATION (Air Conditioning and Heating) STUDENT GRADE RECORD Career & Technical Education
STUDENT GRADE RECORD Career & Technical Education Course Outline Modules Windham Module Test Module Competenc y Rating WINDHAM SCHOOL DISTRICT 1. CTE Orientation 2. Introduction to Automotive Heating,
More informationTemptek Auxiliary Equipment
Temptek Auxiliary Equipment Mold Temperature Controllers - Water Units VT-275-LX VT Series Mold Temperature Controllers are used to process temperature control to 250 F. These units use an incoloy heater
More informationAHRI Standard 1250P (I-P) 2009 Standard for Performance Rating of Walk-In Coolers and Freezers
AHRI Standard 1250P (I-P) 2009 Standard for Performance Rating of Walk-In Coolers and Freezers - ERRATA SHEET FOR AHRI STANDARD 1250 (I-P)-2009, PERFORMANCE RATING OF WALK-IN COOLERS AND FREEZERS December
More informationEnergy-Saving Industrial Water Chillers
Energy-Saving Industrial Water Chillers Cycling operation saves power Large storage reservoir Stainless steel pump Microprocessor controls MPC Industrial Water Chillers Motivair is a world-class supplier
More informationApplication Engineering
Revised September, 2006 ECONOMIZED VAPOR INJECTION (EVI) COMPRESSORS INDEX SECTION PAGE 1. Introduction... 1 2. Theory of Operation... 1 3. Nomenclature... 3 4. ARI Low Temperature Ratings... 3 5. Approved
More informationSERVICE MANUAL FOR MODEL RM-26
SERVICE MANUAL FOR MODEL RM-26 REQUIRED TOOLS CORDLESS DRILL DRIVE CUTTING TUBING OPEN WRENCH OF 1/2 RATCHET WITH SOCKET OF 7/16 SCREWDRIVER SET WITH SOCKET OF 9/32 VISE GRIP PIERCING VALVE WATCHER SLOTTED
More informationTechnical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler
Technical Development Program COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Introduction System
More informationOPERATION AND SERVICE for
T-313 Manual OPERATION AND SERVICE for 68RM50-100/101 MICROMAX T-313 REV. 07/2012 2012 Mobile Climate Control SAFETY SUMMARY GENERAL SAFETY NOTICES The following general safety notices supplement the specific
More informationINSTALLATION, OPERATION, SERVICE & PARTS SUPPLEMENT for
T-333 Manual INSTALLATION, OPERATION, SERVICE & PARTS SUPPLEMENT for Rooftop Energy Storage Systems (ESS) AIR COOLING UNIT 77-62186-00 THRU -04 & 77-62203-00 T-333 REV. 03/2012 2012 Mobile Climate Control
More informationSECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.
SECTION 15650 REFRIGERATION EQUIPMENT PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories. B. Related Section: 1. 11400
More informationWORKSHEET 4-4 (ON-CAR) HFC-134a Recovery
WORKSHEET 4-4 (ON-CAR) HFC-134a Recovery TOYOTA AIR CONDITIONING AND CLIMATE CONTROL Vehicle: Year/Prod. Date: Engine: Transmission: Worksheet Objectives: Given this worksheet, a Toyota vehicle, a Vehicle
More informationRefrigerant changeover guidelines
Refrigerant changeover guidelines HCFC R-22 to HFC R-407A/F, R-448A or R-449A for medium and low temperature applications HCFC R-22 to HFC R-407C for high, medium and low temperature applications HCFC
More informationOperating instructions for semi-hermetic motorcompressors
Operating instructions Page 1 Operating instructions Type: HG 4/310-8/4 S HG 4/385-8/4 S HG 4/465-8/4 S HG 4/555-8/4 Page 2 Page 3 Contents Page 1. Safety instructions...4 2. Main and functional parts...4
More informationDigital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS
Digital Refrigerant System Analyzer INSTRUCTION MANUAL ENGLISH LOW START PRS T-LOW SUPERHEAT MAXMIN kpa Bar MPa R TIME P T HIGH END PRS T-HIGH SUBCOOL VAC 1-800-547-5740 Fax: (503) 643-6322 www.ueitest.com
More informationSPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module
SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:
More informationHorizon Elite Ice Machine Installation Instructions for Remote Condensing Unit
Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit HCD/HMD/HCF/HMF1010R HCD/HMD/HCF/HMF1410R Order parts online www.follettice.com Drop-in Remote Condensing RIDE remote ice
More informationRC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit
SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit RCW-54CB RO-50CA RC-54CA RO-50CA RC-54HA RO-50HA CONTENTS SPECIFICATIONS OUTLINE AND DIMENTIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM
More informationJEFFERSON COLLEGE COURSE SYLLABUS HRA125 REFRIGERATION AND A/C MECHANICAL SYSTEMS. 5 Credit Hours. Prepared by William Kaune November 30, 2010
JEFFERSON COLLEGE COURSE SYLLABUS HRA125 REFRIGERATION AND A/C MECHANICAL SYSTEMS 5 Credit Hours Prepared by William Kaune November 30, 2010 Mary Beth Ottinger, Division Chair, Business & Technical Education
More informationIntroduction to Refrigeration Unit TIR
Engineering and Technical Teaching Equipment Introduction to Refrigeration Unit TIR PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION ISO 9001: Quality Management (for Design, Manufacturing, Commercialization
More information1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.
WYETH-AYERST CANADA INC. 1025, BOUL. MARCEL-LAURIN S T - L A U R E N T, Q U É B E C INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER MODEL P448800LT--55WC--22C66S Prepared par Claude Gadoury, P.
More informationWater chillers water/water type SIGMA Technical information manual
Water chillers water/water type SIGMA Technical information manual 2 INDEX Technical features 1 Versions 3 Accessory versions 4 Technical data 7 Electrical data 11 Cooling capacity 12 Heating capacity
More informationy Small dimensions. Easy to install in refrigerated counters or cold rooms
MAKING MODERN LIVING POSSIBLE Data sheet Thermostat Type KP The KP Thermostats are temperaturecontrolled electrical switches. All KP Thermostats have a single pole double throw (SPDT) changeover switch.
More informationInstallation, Start-Up and Service Instructions
38AH044-134 Air-Cooled Condensing Units 50/60 Hz Installation, Start-Up and Service Instructions CONTENTS Page SAFETY CONSIDERATIONS...................... 1 INSTALLATION................................
More informationSome of these procedures need to be performed to conform to requirements of the Clean Air Act.
Leak Detection, Recovery, Evacuation and Charging Four basic service procedures used to repair and maintain a mechanical refrigeration system are leak detection, evacuation, recovery, and refrigerant charging.
More informationMACH N-407 Heat Pump Air-Cooled Chiller
MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS MODEL LV8 COMMERCIAL REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 A01001 7/11/96 NRP-OM-LV8 7/96
More informationHVAC Basics RESIDENTIAL AIR CONDITIONING
HVAC Basics RESIDENTIAL AIR CONDITIONING Introduction This Instructor s Guide provides information to help you get the most out of Residential Air Conditioning, part of the two-part series HVAC Basics.
More informationBASIC HEAT PUMP THEORY By: Lloyd A. Mullen By: Lloyd G. Williams Service Department, York Division, Borg-Warner Corporation
INTRODUCTION In recent years air conditioning industry technology has advanced rapidly. An important byproduct of this growth has been development of the heat pump. Altogether too much mystery has surrounded
More informationEC3-X33 Stand-alone Superheat Controller Technical Data
Technical Data EC3-X33 is a stand-alone universal superheat controller for air conditioning, refrigeration and industrial applications such as chillers, industrial process cooling, rooftops, heat pumps,
More informationCentriVap. Centrifugal Vacuum Concentrators and Cold Traps
CentriVap Centrifugal Vacuum Concentrators and Cold Traps 2 CENTRIVAP VACUUM CONCENTRATORS & COLD TRAPS Page An Overview 2 CentriVap Benchtop Vacuum Concentrators 4 Refrigerated CentriVap Vacuum Concentrators
More informationOPERATION & MAINTENANCE MANUAL TC670
OPERATION & MAINTENANCE MANUAL TC670 Refrigerant Management Center (Convertible For Use With R12 or R134a) RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80342-02 TC670 CONVERTIBLE
More informationA-4400 Series Refrigerated Air Dryers for Pneumatic Control Systems
Pneumatic Air Supply Manual 718 Air Dryers Section Product Bulletin A-4400 Issue Date 1213 A-4400 Series Refrigerated Air Dryers for Pneumatic Control s The A-4400 Series Refrigerated Air Dryers are designed
More information