GRUNDFOS DATA BOOKLET MTB. Centrifugal machine tool pumps 50/60 Hz

Size: px
Start display at page:

Download "GRUNDFOS DATA BOOKLET MTB. Centrifugal machine tool pumps 50/60 Hz"

Transcription

1 GRUNDFOS DATA BOOKLET Centrifugal machine tool pumps 5/6 Hz

2 Contents General description Introduction 3 Applications 3 Special features 3 Identification Type key Codes Pump types and data Construction Sectional drawing 5 Material specification 5 Mounting 5 Mechanical construction 5 Surface treatment 6 Test pressure 6 Motor 7 Operating conditions Inlet pressure Maximum operating pressure Ambient temperature and altitude 9 Performance curves/ Technical data 5-2, -pole, 5 Hz , 2-pole, 5 Hz , 2-pole, 5 Hz 2 5-2, -pole, 6 Hz , 2-pole, 6 Hz , 2-pole, 6 Hz 26 Accessories Support blocks 2 Service Spare parts 29 Further product documentation WebCAPS 3 WinCAPS 31 Installation Positioning 1 Vertical installation 1 Horizontal installation 1 Pipework 1 Foundation 1 Elimination of noise and vibration 11 Selection of product Pump size 12 Efficiency 12 Shaft seal material 12 Pumped liquids Pumped liquids 13 List of pumped liquids 13 Curve charts How to read the curve charts 15 Curve conditions 15 Calculation of total head 15 2

3 General description Introduction The machine tool pumps are single-stage centrifugal pumps with axial suction port and radial discharge port. The unique SuperVortex impeller is capable of handling solids and swarf up to 2 mm. The pump is directly coupled to a totally enclosed fancooled standard motor. Main dimensions are according to IEC and DIN standards. Applications The pumps are designed specifically for industrial machine tool and cleaning applications such as machining centres cooling systems grinding machines lathes parts-cleaning systems. Special features Because of the back-pull-out design, the motor and impeller can be removed without dismantling the pump housing or pipework. This makes it possible for a single person and a crane to service even the largest pump. TM Fig. 1 Back-pull-out design Additional features EFF 1 motor as standard Excellent solids handling capabilities Good air handling LiqTec sensor ensures that the pump stops immediately in the event of dry running Motor with integrated frequency converter as an option Different shaft seal solutions Full range of industrial pumps. 3D CAD drawings and technical information can be found in the Grundfos pump selection tools, WebCAPS and WinCAPS. See pages 3 to 31. 3

4 Identification Type key Example 65-2 /199 A -F -A -BQQV Pump range Nominal diameter of discharge port (DN) Housing size Actual impeller diameter [mm] Code for pump version Code for pipework connection Pump types and data Pump type 5 Hz 6 Hz Design P2 [kw] Number of poles Page 5-2/215 A /15 A /171 A /13 B /199 B /13 A /199 A /215 A /1 A /15 B /171 B Code for material Code for shaft seal and rubber pump parts The example describes an 65-2 pump with an actual impeller diameter of 199 mm, of the basic version, with DIN flanges, made of cast iron and with a BQQV shaft seal. Codes Example A - F - A - B Q Q V Pump version A Basic version Pipe connection F DIN flange Materials A Cast iron Shaft seal B Rubber bellows seal Q Silicon carbide (SiC) P NBR (nitrile) V FKM The pump is fitted with FKM O-rings as standard.

5 Construction Sectional drawing a Mounting is available in these designs: Design A: pump housing with feet Design B: motor with feet. See figures 3 and. TM Fig. 3, Design A 27 19a a TM TM Fig. 2 Sectional drawing, 5-2 Material specification Pos. Part Material 2 Pump head Cast iron, EN-GJL-25 6 Pump housing Cast iron, EN-GJL Air vent screw Brass 19 Plug - 19a Plug - 26 Nut - 27 Nut - 9 Impeller Cast iron, EN-GJL Pump shaft Stainless steel, AISI 3 72a O-ring FKM 15a Mechanical seal SiC/SiC, FKM 115 Seal spacer Stainless steel, AISI 3 Fig., Design B Mechanical construction Pump Designs 5 Hz 6 Hz 5-2 A A A A B 65-2 B - 5

6 Construction Pump housing Volute pump housing made of cast iron with axial suction port and radial discharge port. Flange connection dimensions are in accordance with EN The bottom of the pump housing incorporates a drain plug. The discharge port has a pressure gauge tapping. Pump head Combining pump housing and motor, the pump head is provided with a manual air vent screw for the venting of pump housing and seal chamber. An O-ring provides a seal between pump head and pump housing. Coupling guards are fitted in the central part of the pump head. To remove the pump head from the pump housing, use a lever between the pump housing and the pump head. pumps are fitted with the following motor flange types: type IM B 5 for motor sizes up to MMG 132 (according to IEC 63) type IM B 35 for motor size MMG 16 (according to IEC 63). Shaft Stainless steel shaft of 2 or 3 mm. The coupling end of the shaft is cylindrical and has two drilled holes for the shaft pin of the coupling. Shaft seal pumps are fitted with an unbalanced, mechanical SiC/SiC shaft seal with FKM as standard material. NBR material is available on request. A brief liquid circulation during start-up, by manually opening the air vent screw in the pump head, ensures perfect lubrication and cooling of the shaft seal. Coupling pumps are fitted with a cylindrical, hollow steel coupling secured by two hexagon socket head screws. Impeller The semi-open impeller is made of cast iron. All pumps are dynamically balanced. The impeller is hydraulically balanced to compensate for axial thrust. The impeller is extremely suitable for handling swarf and solids. Spherical impeller clearance: Max. 2 mm. Note: When viewed from the motor fan, the impeller rotates clockwise. Surface treatment All stationary cast iron parts are dip-painted with waterbased ether-epoxy no-lead painting. Thickness: 25 μm ±5 μm. In addition, the product is spray-painted with black water-based ether-epoxy no-lead painting (NCS 9/ RAL 95). Thickness: 35 μm ±5 μm. Test pressure Before delivery, the pumps have been tested at 1.5 times maximum operating pressure. Test requirements according to EN 733 are 1.3 times maximum operating pressure. Test liquid: Water, 2 C. Maximum operating temperature and pressure Shaft seal Operating temperature Maximum operating pressure [bar] BQQV C to +9 C 16 bar BQQP C to +9 C 16 bar 6

7 Construction Motor pumps are equipped with a totally enclosed, fancooled, EFF 1 motor with main dimensions to IEC and DIN standards. 5 Hz Output P 2 [kw] EFF 1 motor range 2-pole -pole 3. MG, model D MG, model D Siemens 6 Hz 3.. MG, model D 5.5 Siemens 7.5 MG, model D Siemens Motor data Type IM B 5 for motor sizes up to MMG 132, Flange types according to IEC 63. Type IM B 35 for motor size MMG 16, according to IEC 63. Insulation class F, according to IEC 5 Electrical tolerances According to VDE 53 Efficiency class Standard range: EFF 1 Enclosure class IP 55 Supply voltage, 5 Hz Supply voltage, 6 Hz 3 x 22-2 V Δ / 3-15 V Y 3 x 3-15 V Δ 3 x 3-15 V Δ / V Y 3 x V Δ / 3- V Y 3 x 3-15 V Δ 3 x 3-15 V Δ / V Y pumps are also available with special voltage Supply voltage, 5 Hz 3 x 2-22 V Δ / 36-3 V Y Supply voltage, 6 Hz 3 x 2-23 V Δ / 36- V Y The motor must be connected to a motor starter in accordance with local regulations. 7

8 Operating conditions Inlet pressure Minimum inlet pressure according to the NPSH curve plus a safety allowance of at least 2 m. The maximum inlet pressure is limited by the maximum operating pressure. Minimum inlet pressure - NPSH Calculation of the inlet pressure "H" is recommended when the liquid temperature is high the flow is significantly higher than the rated flow water is drawn from depths water is drawn through long pipes inlet conditions are poor. To avoid cavitation, make sure that there is a minimum pressure on the suction side of the pump. The maximum suction lift "H" in metres head can be calculated as follows: H = p b x 1.2 NPSH H f H v H s p b = Barometric pressure in bar. (Barometric pressure can be set to 1 bar.) In closed systems, p b indicates the system pressure in bar. NPSH = Net Positive Suction Head in metres head. (To be read from the NPSH curve at the highest flow the pump will be delivering.) H f = Friction loss in suction pipe in metres head. (At the highest flow the pump will be delivering.) H v = Vapour pressure in metres head. (To be read from the vapour pressure scale. "H v " depends on the liquid temperature "T m ".) H s = Safety margin = minimum 2 metres head. If the "H" calculated is positive, the pump can operate at a suction lift of maximum "H" metres head. If the "H" calculated is negative, an inlet pressure of minimum "H" metres head is required. H P b H f Fig. 5 Schematic view of open system with pump Fig. 6 Relation between liquid temperature and vapour pressure Check that the pump is not and will not be exposed to cavitation. Maximum operating pressure Up to +9 C: H v tm ( C) NPSH Hv (m) , 9 6, 5,, 7 3, 6 2, 1,5 5 1,,,6 3,,3 2,2 1,1 1.6 MPa (16 bar). TM TM

9 Operating conditions Ambient temperature and altitude Motor make Motor efficiency class Maximum ambient temperature [ C] Maximum altitude above sea level [m] Grundfos MG EFF If the ambient temperature exceeds the above temperature value or the pump is installed at an altitude exceeding the above altitude value, the motor must not be fully loaded due to the risk of overheating. Overheating may result from excessive ambient temperatures or the low density and consequently low cooling effect of the air. In such cases, it may be necessary to use a motor with a higher rated output. P2 [%] 1 EFF t [ C] m Fig. 7 Motor P2 depends on temperature/altitude TM

10 Installation Positioning The pump should never be installed with the motor pointing downwards. If the pump has been installed with the terminal box pointing downwards, turn the motor to the required position. Horizontal installation Pumps fitted with 3- kw motors require a 3 mm clearance behind the motor. See fig. 1. Pumps fitted with motors of 5.5 kw and up require a 3 mm clearance behind the motor and a 1 metre clearance above the motor to allow the use of lifting equipment. See fig kw Fig. Installation Vertical installation Pumps fitted with 3- kw motors require a 3 mm clearance above the motor. See fig. 9. Pumps fitted with motors of 5.5 kw and up require at least a 1 metre clearance above the motor to allow the use of lifting equipment. See fig kw kw 3 mm 1 m TM Fig. 1 Horizontal installation Pipework kw 1 m 3 mm 3 mm When installing the pipes, ensure that the pump housing is not stressed by the pipework. The suction and discharge pipes must be of an adequate size, taking into account the pump inlet pressure. TM Fig. 9 Vertical installation TM Foundation We recommend that you install the pump on a plane and rigid concrete foundation which is heavy enough to provide permanent support for the entire pump. As a rule of thumb, the weight of the concrete foundation should be 1.5 times the pump weight. See fig

11 Installation Elimination of noise and vibration In order to achieve optimum operation and minimum noise and vibration, consider vibration dampening of the pump. Generally, always consider this for pumps with motors above 7.5 kw. Smaller motor sizes, however, may also cause undesirable noise and vibration. Noise and vibration are generated by the revolutions of the motor and pump and by the flow in pipes and fittings. The effect on the environment is subjective and depends on correct installation and the state of the remaining system. Elimination of noise and vibrations is best achieved by means of vibration dampers and expansion joints. See fig. 11. Expansion joint Concrete foundation Vibration damper TM Expansion joints If you install the pump on a foundation with vibration dampers, always fit expansion joints on the pump flanges. This is important to prevent the pump from "hanging" in the flanges. Install expansion joints to absorb expansions/contractions in the pipework caused by changing liquid temperature reduce mechanical strains in connection with pressure surges in the pipework isolate mechanical structure-borne noise in the pipework (only rubber bellows expansion joints). Note: Do not install expansion joints to compensate for inaccuracies in the pipework such as centre displacement of flanges. Fit expansion joints at a distance of minimum 1 to 1½ times the nominal flange diameter away from the pump on the suction as well as on the discharge side. This will prevent the development of turbulence in the expansion joints, resulting in better suction conditions and a minimum pressure loss on the pressure side. At high water velocities (> 5 m/s), we recommend you to install larger expansion joints corresponding to the pipework. We always recommend expansion joints with limiting rods for flanges larger than DN 1. Fig. 11 pump with expansion joints and vibration dampers Vibration dampers To prevent the transmission of vibrations to buildings, we recommend you to isolate the pump foundation from building parts by means of vibration dampers. The selection of the right vibration damper requires the following data: forces transmitted through the damper motor speed considering speed control, if any required dampening in % (suggested value is 7 %). Which is the right damper varies from installation to installation, and a wrong damper may increase the vibration level. Vibration dampers should therefore be sized by the supplier. 11

12 Selection of product Pump size The selection of pump size should be based on: required flow and pressure at the draw-off point pressure loss as a result of height differences friction loss in the pipework It may be necessary to account for pressure loss in connection with long pipes, bends or valves, etc. best efficiency at the estimated duty point. TM Fig. 12 Schematic drawing of an installation Efficiency If you expect the pump to always operate in the same duty point, select a pump which is operating in a duty point corresponding to the best efficiency of the pump. In case of controlled operation or varying consumption, select a pump whose best efficiency falls within the duty range covering the greater part of the duty time. Shaft seal material As standard, the pump comes with an FKM O-ring. O- rings are also available in NBR. The material variant should be selected on the basis of the liquid to be pumped. See page

13 Pumped liquids Pumped liquids Liquid temperature: C to +9 C. Dirty, thin, non-explosive liquids containing swarf or solids up to 2 mm. The liquid must not attack the pump mechanically or chemically. List of pumped liquids A number of typical liquids are listed below. Other pump versions may be applicable, but those stated in the list are considered to be the best choices. The table is intended as a general guide only and cannot replace actual testing of the pumped liquids and pump materials under specific working conditions. However, use the list with some caution, as factors such as concentration of the pumped liquid liquid temperature pressure particle size may affect pump life and cause shaft seal problems. Pumped liquid Note Additional information Shaft seal Coolant in machine tool Water-based coolant Synthetic lubricating oil Cleaning Consider motor size and/or pump performance due to the density and/or viscosity. Soap (salts of fatty acids) < C Alkaline degreasing < C Mineral oils Crude oil Mineral lubricating oil Consider motor size and/or pump performance due to the density and/or viscosity. BQQV (BQQP) BQQV (BQQP) BQQV (BQQP) BQQP (BQQV) < 2 C BQQV BQQV 13

14 1

15 Curve charts How to read the curve charts Total pump head H = H total p [kpa] H [m] 36 /171 3 % 1 % % pole, 6 Hz ISO 996 Annex A Pump type, number of poles and frequency /15 % 9.1 % QH curve for the individual pump. Dimension of impeller % 2 % NPSH 1 % /171 /15 NPSH [m] 12 The power curves indicate pump input power [P 2 ] Q [m³/h] v [m/s] P2 [kw] 1 /171 The NPSH curve is an average curve for all the variants shown. When sizing the pumps, add a safety margin of at least 2 m / Q [m³/h] Q [l/s] TM Curve conditions The following guide lines apply to the curves shown from page to 16: The curve values have been tested at a water temperature of 2 C. The curves apply to the actual speed of the motor types stated at 5 Hz. The conversion between head "H [m]" and pressure "p [kpa]" applies to water with a density of ρ = 1 kg/m 3. In case of densities other than 1 kg/m 3, the discharge pressure is proportional to the density. When pumping liquids with a density higher than 1 kg/m 3, motors with correspondingly higher outputs must be used. The curves apply to a kinematic viscosity of ν =1mm 2 /s (1 cst). Maximum kinematic viscosity without any new calculation of motor size being necessary is 3 mm 2 /s. Tolerances according to ISO 996, Annex A. The pumps should not be used at minimum flows below.1 x Q at an optimum efficiency because of the danger of overheating of the pump. NPSH: The curves stated are average values found under the same conditions as the performance curves. Liquid: Air-free water. When sizing, add a safety allowance of at least 2 m. v (m/s) indicates flow velocity in discharge port. Calculation of total head The total pump head consists of the height difference between the measuring points + the differential head + the dynamic head. H total = H geo + H stat + H dyn Legend H geo H stat H dyn = Height difference between the measuring points = Differential head between the suction and the discharge side of the pump. = Calculated values based on the velocity of the pumped liquid on the suction and the discharge side of the pump. 15

16 Performance curves/ Technical data 5-2 -pole, 5 Hz 5-2, -pole, 5 Hz p [kpa] H [m] /215 2 % 6 % 9 % 51 % 51.7 % pole, 5 Hz ISO 996 Annex A % % 9 6 % 2 % NPSH [m] 6 1 NPSH Q [m³/h] P2 [kw] v [m/s] 2. / Q [m³/h] Q [l/s] TM

17 Technical data 5-2 -pole, 5 Hz TM TM EN PN 16 Nominal diameter (DN) 5 65 D D D S x 19 x 19 x TM x [mm] Motor only 6 Motor and 1 pump head Minimum clearance for removal of motor/pump head Dimensions and weights Pump type Motor [kw] Dimensions [mm] DNs DNd a AD AG b G1 G2 h1 h2 L LL LB m1 m2 n1 n2 P s1 5-2/ M12 65 Net weight [kg] Electrical data 3 x 22-2 V Δ / 3-15 V Y P Pump type Motor type 2 I 1/1 η max Power factor n I [kw] [A] [%] cos ϕ [min start ] I /215 MG 1LC-D /

18 Performance curves pole, 5 Hz 65-16, 2-pole, 5 Hz p [kpa] 2 H [m] / % % 3 % pole, 5 Hz ISO 996 Annex A /15 7 %.9 % % 3 % 7 % % 37 % 6 NPSH /15 /171 NPSH [m] Q [m³/h] v [m/s] P2 [kw] / / Q [m³/h] Q [l/s] TM

19 Technical data pole, 5 Hz TM TM EN PN 16 Nominal diameter (DN) 65 D 1 65 D D S x 19 x 19 x TM x [mm] Motor only Motor and 1 pump head Minimum clearance for removal of motor/pump head Dimensions and weights Pump type Motor [kw] Dimensions [mm] DNs DNd a AD AG b G1 G2 h1 h2 L LL LB m1 m2 n1 n2 P s / M / M12 5 Net weight [kg] Electrical data 3 x 3-15 V Δ Pump type Motor type P 2 I 1/1 η max Power factor n I [kw] [A] [%] cos ϕ [min start ] I /15 MG 132SC-D /171 MG 132SD-D

20 Performance curves pole, 5 Hz 65-2, 2-pole, 5 Hz p [kpa] 5 H [m] 5 5 / pole, 5 Hz ISO 996 Annex A 53 % 35 /13 56 % 59 % 59.2 % 59 % % % /199 NPSH [m] /13 5 NPSH Q [m³/h] v [m/s] P2 [kw] /199 / Q [m³/h] Q [l/s] TM

21 Technical data pole, 5 Hz TM TM EN PN 16 Nominal diameter (DN) 65 D 1 65 D D S x 19 x 19 x TM x [mm] Motor only 11 Motor and 1 pump head Minimum clearance for removal of motor/pump head Dimensions and weights Pump type Motor [kw] Dimensions [mm] DNs DNd a A AD AG B C G1 G2 H h2 K L LB LL P 65-2/ / Motor feet are to be underpinened by support blocks, see Accessories on page 2 Net weight [kg] Electrical data 3 x 3-15 V Δ Pump type Motor type P 2 I 1/1 η max Power factor n I [kw] [A] [%] cos ϕ [min start ] I /13 Siemens 16M / /199 Siemens 16M /

22 Performance curves 5-2 -pole, 6 Hz 5-2, -pole, 6 Hz p [kpa] 2 22 H [m] 2 22 / pole, 6 Hz ISO 996 Annex A % 2 % 5 % 7 % 1 1 / % 1 1 /13. % 7 % % 5 % 2 % % NPSH [m] 12 /13 / NPSH / Q [m³/h] P2 [kw] v [m/s] / / / Q [m³/h] Q [l/s] TM

23 Technical data 5-2 -pole, 6 Hz TM TM EN PN 16 Nominal diameter (DN) 5 65 D D D S x 19 x 19 x TM x [mm] (-/13 and -/199) x [mm] (-/215) Motor only 6 Motor and pump head 1 1 Minimum clearance for removal of motor/pump head Dimensions and weights Pump type Motor [kw] Dimensions [mm] DNs DNd a AD AG b G1 G2 h1 h2 L LL LB m1 m2 n1 n2 P s1 5-2/ M / M12 5-2/ M12 7 Net weight [kg] Electrical data 3 x V Δ / 3- V Y Pump type Motor type P 2 I 1/1 η Power factor n I [kw] [A] [%] cos ϕ [min start ] I /13 MG 1LC-D / /199 MG 112MC-D / /215 Siemens 132S /

24 Performance curves pole, 6 Hz , 2-pole, 6 Hz p [kpa] 2 2 H [m] /1 36 % 39 % 1 % 3 % pole, 6 Hz ISO 996 Annex A % 1 3 % % 39 % 6 NPSH /1 NPSH [m] Q [m³/h] P2 [kw] v [m/s] 7 / Q [m³/h] Q [l/s] TM

25 Technical data pole, 6 Hz TM TM EN PN 16 Nominal diameter (DN) 65 D 1 65 D D S x 19 x 19 x TM x [mm] Motor only Motor and 1 pump head Minimum clearance for removal of motor/pump head Dimensions and weights Pump type Motor [kw] Dimensions [mm] DNs DNd a AD AG b G1 G2 h1 h2 L LL LB m1 m2 n1 n2 P s / M12 7 Net weight [kg] Electrical data 3 x 3-15 V Δ P Pump type Motor type 2 I 1/1 η max Power factor n I [kw] [A] [%] cos ϕ [min start ] I /1 MG 132SD-D

26 Performance curves pole, 6 Hz 65-16, 2-pole, 6 Hz p [kpa] H [m] 36 /171 3 % 1 % % pole, 6 Hz ISO 996 Annex A /15 % % % 2 % % NPSH [m] 12 NPSH /171 / Q [m³/h] P2 [kw] v [m/s] / / Q [m³/h] Q [l/s] TM

27 Technical data pole, 6 Hz TM TM EN PN 16 Nominal diameter (DN) 65 D 1 65 D D S x 19 x 19 x TM x [mm] Motor only 11 Motor and 1 pump head Minimum clearance for removal of motor/pump head Dimensions and weights Pump type Motor [kw] Dimensions [mm] DNs DNd a A AD AG B C G1 G2 H h2 K L LB LL P 65-16/ / Motor feet are to be underpinened by support blocks, see Accessories on page 2 Net weight [kg] Electrical data 3 x 3- V Δ / V Y Pump type Motor type P 2 I 1/1 η Power factor n I [kw] [A] [%] cos ϕ [min start ] I /15 Siemens 16M / /171 Siemens 16M /

28 Accessories Support blocks During installation, support blocks can be fitted under the motor feet in order to compensate for dimensional differences between pump housing and motor frame sizes, thus enabling easy horizontal mounting of the pumps. The product number refers to a set of two support blocks having the dimensions specified in the following table. Pump type P 2 [kw] Dimensions W x L x H [mm] Product number 5 Hz 65-2/ x 332 x / Hz 65-16/ x 332 x /

29 Service Spare parts Available spare parts kits. Mechanical shaft seal complete Shaft with spacing bush Impeller. For more information on spare parts and kits, see Grundfos WinCAPS/WebCAPS or the Grundfos Service Kit Catalogue. 29

30 Further product documentation WebCAPS WebCAPS is a Web-based Computer Aided Product Selection program available on WebCAPS contains detailed information on more than 15, Grundfos products in more than 2 languages. In WebCAPS, all information is divided into 6 sections: Catalogue Literature Service Sizing Replacement CAD drawings. Catalogue This section is based on fields of application and pump types, and contains technical data curves (QH, Eta, P1, P2, etc.) which can be adapted to the density and viscosity of the pumped liquid and show the number of pumps in operation product photos dimensional drawings wiring diagrams quotation texts, etc. Literature In this section you can access all the latest documents of a given pump, such as data booklets installation and operating instructions service documentation, such as Service kit catalogue and Service kit instructions quick guides product brochures. Service This section contains an easy-to-use interactive service catalogue. Here you can find and identify service parts of both existing and discontinued Grundfos pumps. Furthermore, this section contains service videos showing you how to replace service parts. 3

31 1 Further product documentation Sizing This section is based on different fields of application and installation examples, and gives easy step-by-step instructions in how to select the most suitable and efficient pump for your installation carry out advanced calculations based on energy consumption, payback periods, load profiles, life cycle costs, etc. analyse your selected pump via the built-in life cycle cost tool determine the flow velocity in wastewater applications, etc. Replacement In this section you find a guide to selecting and comparing replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos. Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency. CAD drawings In this section it is possible to download 2-dimensional (2D) and 3- dimensional (3D) CAD drawings of most Grundfos pumps. These formats are available in WebCAPS: 2-dimensional drawings:.dxf, wireframe drawings.dwg, wireframe drawings. 3-dimensional drawings:.dwg, wireframe drawings (without surfaces).stp, solid drawings (with surfaces).eprt, E-drawings. WinCAPS WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed information on more than 15, Grundfos products in more than 2 languages. The program contains the same features and functions as WebCAPS, but is an ideal solution if no Internet connection is available. WinCAPS is available on CD-ROM and updated once a year. Fig. 13 WinCAPS CD-ROM 31

32 Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence Repl GB Subject to alterations. GRUNDFOS A/S. DK-5 Bjerringbro. Denmark Telephone:

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz GRUNDFOS DATA BOOKLET Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz Table of contents 1. Product data 3 Introduction 3 Performance range 4 Product range 6 Type key 9 Operating conditions

More information

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ GRUNDFOS DATA BOOKLET CR45-12-2 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 96122818 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96122818/cr-45-12-2-a-f-a-e-hqqe.html

More information

CR A-F-A-V-HQQV 3x400D 50 HZ

CR A-F-A-V-HQQV 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR9-1-1 A-F-A-V-HQQV 3x4D 5 HZ Grundfos Pump 9612486 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612486/cr-9-1-1-a-f-a-v-hqqv.html

More information

CRN A-F-G-E-HQQE 3x400D 50 HZ

CRN A-F-G-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN45-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96123118 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn45/96123118/crn-45-2-2-a-f-g-e-hqqe.html

More information

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR64-1 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 96123527 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123527/cr-64-1-a-f-a-e-hqqe.html

More information

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN9-1 A-F-G-V-HQQV 3x4D 5 HZ Grundfos Pump 96124237 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn9/96124237/crn-9-1-a-f-g-v-hqqv.html

More information

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR32-4 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9612213 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612213/cr-32-4-a-f-a-e-hqqe.html

More information

CR A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR64-2-2 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 96123528 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123528/cr-64-2-2-a-f-a-e-hqqe.html

More information

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ GRUNDFOS DATA BOOKLET CR5-9 A-FGJ-A-E-HQQE 1x2/24 5HZ Grundfos Pump 96537532 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96537532/cr-5-9-a-fgj-a-e-hqqe.html

More information

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR1-16 A-FJ-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9651222 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9651222/cr-1-16-a-fj-a-e-hqqe.html

More information

TP /4-A-F-A-BQQE 400D 50HZ

TP /4-A-F-A-BQQE 400D 50HZ GRUNDFOS DATA BOOKLET TP 15-7/-A-F-A-BQQE D 5HZ Grundfos pump 989838 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/989838/tp-15-7--a-f-a-bqqe.html

More information

CR20-07 A-F-A-E-HQQE 3x400/ HZ

CR20-07 A-F-A-E-HQQE 3x400/ HZ GRUNDFOS DATA BOOKLET CR2-7 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos pump 965513 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crfam/965513/cr-2-7-a-f-a-e-hqqe.html

More information

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ GRUNDFOS DATA BOOKLET CR32--2 A-F-A-E-HQQE 3x/69 5 HZ Grundfos pump 9612212 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crfam/9612212/cr-32--2-a-f-a-e-hqqe.html

More information

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz GRUNDFOS DATA BOOKLET Grundfos booster systems with two or three CM, CMV or CR pumps 50 Hz Table of contents 1. Product introduction 3 2. Performance range 4 with CM pumps 4 with CMV pumps 4 with CR pumps

More information

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz GRUNDFOS DATA BOOKLET UPS2 Circulator pumps 50/60 Hz UPS2 Table of contents 1. Product introduction 3 Type key.................................................................................... 3 Performance

More information

SL S.S.N.51D

SL S.S.N.51D GRUNDFOS DATA BOOKLET SL1.8..265.2.52S.S.N.51D Grundfos Pump 9814549 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/seslfam/9814549/sl1-8--265-2-52s-s-n-51d.html

More information

SL EX.4.51D

SL EX.4.51D GRUNDFOS DATA BOOKLET SL1.1.1.75.EX.4.51D Grundfos pump 962669 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/sl1/962669/sl1-1-1-75-ex-4-51d-c.html

More information

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz GRUNDFOS DATA BOOKLET Circulator pumps 50/60 Hz 2 Product range 2. Product range UP(S) COMFORT, 50/60 Hz Pump type 24-hour timer Supplied with Dimensions Accessories Data sheet Thermostat Isolating valve

More information

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP DS series Industrial End Suction Pumps ISO/DP 5199 www.sterlingpumps.com.au DS series Capacities from: Heads from: 340 to 5,680 m3/h (1,500 to 25,000 USPGM) 21 to 106 metres (70 to 350 feet) Power range

More information

GRUNDFOS PRODUCT GUIDE MAGNA. UPE Series 2000 circulator pumps

GRUNDFOS PRODUCT GUIDE MAGNA. UPE Series 2000 circulator pumps GRUNDFOS PRODUCT GUIDE UPE Series 2000 circulator pumps Contents Mission Product data Features and benefits Applications 5 eating systems 5 Pumped liquids 5 Type key 6 Performance range, 6 Product range

More information

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems. Issued 2006/08/01 Section 15131 Pumps Hydronic Systems Page 1 of 6 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal.3 Section 01780

More information

Company name: Created by: Phone:

Company name: Created by: Phone: Position Qty. Description 1 SL1..1.55..6G.C Product o.: 9655 ote! Product picture may differ from actual product on-self-priming, single-stage, centrifugal pump designed for handling wastewater, process

More information

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s PAPANTONATOS P u m p s s e r v ic e & e n g i nee r in g We supply clean water and remove waste water s e w a g e p u m p s submersible pumps The Company QUALITY WHICH REDUCES PUMPING COSTS For over 45

More information

Chemical Pumps Vertical Chemical Pump Type TNP

Chemical Pumps Vertical Chemical Pump Type TNP Chemical Pumps Vertical Chemical Pump Type TNP In PP / PE-UHMW / PVDF Vertical setting depths up to 00 mm Applications Type TNP vertical chemical pumps are specifically designed to handle acids, alkalis

More information

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz GRUNDFOS DATA BOOKLET Unilift CC, KP, AP Submersible drainage and effluent pumps 50 Hz Contents Product overview General data Performance range 4 Applications 5 Examples of applications 5 Wastewater definitions

More information

GRUNDFOS END SUCTION PUMPS GRUNDFOS END SUCTION PUMPS

GRUNDFOS END SUCTION PUMPS GRUNDFOS END SUCTION PUMPS GRUNDFOS END SUCTION PUMPS GRUNDFOS END SUCTION PUMPS 2 INTRODUCTION PROVEN PUMPS FROM A COMPANY YOU CAN DEPEND ON A global leader in the pump industry, Grundfos has been supplying reliable, innovative

More information

GRUNDFOS DATA BOOKLET SLC, DLC. Pump controllers

GRUNDFOS DATA BOOKLET SLC, DLC. Pump controllers GRUNDFOS DATA BOOKLET Pump controllers Table of contents. Product introduction 3 3 Features and benefits 3 Applications 3 2. Identification Type key 3. Technical data 5. Construction 6 SLC cabinet for

More information

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz GRUNDFOS DATA BOOKLET Unilift CC, KP, AP Submersible drainage and effluent pumps 50 Hz Contents Product overview General data Performance range 4 Applications 5 Examples of applications 5 Pump overview

More information

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER Submersible borehole pump People at KSB we make your world flow round! UPZ PUMP POWER FOR TOP PERFORMANCE UNDER THE TOUGHEST CONDITIONS UPZ is top choice wherever submersible borehole pumps have to satisfy

More information

TYPE LF/LC/LCV END SUCTION PUMPS

TYPE LF/LC/LCV END SUCTION PUMPS PACO LF/LC/LCV TYPE LF/LC/LCV END SUCTION PUMPS Close Coupled and Frame Mounted END SUCTION PUMPS Type LF (Frame Mounted) Type LC (Close Coupled) Type LCV (Vertically Mounted Close Coupled) Grundfos CBS

More information

UP/UPS-B/UPN Hot Water Service Circulators

UP/UPS-B/UPN Hot Water Service Circulators UP/UPS-B/UPN Hot Water Service Circulators Visions & Values It is the Vision of the Company to achieve our Corporate Mission by providing quality and innovative products and services that give our customers

More information

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y HVN. Double Suction, Heavy Duty API 610 Process Pump (BB2)

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y HVN. Double Suction, Heavy Duty API 610 Process Pump (BB2) N N O V A T I O N E F F I C I E N C Y Q U A L I T Y HVN For more than 60 years the name Ruhrpumpen has been synonymous worldwide with innovation and reliability for pumping technology The Ruhrpumpen range

More information

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz GRUNDFOS DATA BOOKLET Unilift CC, KP, AP Submersible drainage and effluent pumps 50 Hz Contents Product overview Unilift CC, KP, AP 3 General data Performance range 4 Applications 5 Examples of applications

More information

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

HTM Circulation Pumps acc. to DIN EN 733 Type NKX HTM Circulation Pumps acc. to DIN EN 733 Type NKX General The new NKX pump line replaces our former heat transfer oil circulation pump type NKL s. The outer dimensions of both pump types are identical

More information

IMMERSIBLE PUMPS FOR INDUSTRY

IMMERSIBLE PUMPS FOR INDUSTRY GRUNDFOS INDUSTRIAL SOLUTIONS Grundfos MTR, MTH, MTA, MTS pumps IMMERSIBLE PUMPS FOR INDUSTRY COMPACT TANK TOP SOLUTIONS FOR DEMANDING APPLICATIONS RENOWNED FOR THEIR RELIABILITY AND PRECISION MTA MTH

More information

Combi Modular System. Standardised centrifugal pumps EN 733 ISO 2858 ISO 5199 API 610

Combi Modular System. Standardised centrifugal pumps EN 733 ISO 2858 ISO 5199 API 610 Combi Modular System Standardised centrifugal pumps EN 733 ISO 2858 ISO 5199 API 610 SPX FLOW Johnson Pump brand water, chemical and petrochemical standardised pumps represent a range of centrifugal pumps

More information

dualarm Vertical In-Line Pumps

dualarm Vertical In-Line Pumps Series 430 & 438 dualarm Vertical In-Line Pumps FILE NO: 43d.1 DATE: Jan. 0, 010 SUPERSEDES: 43d.1 DATE: Sept., 008 Series 430 & 438 Smart pumps for the commercial HVAC market. Armstrong Vertical In-Line

More information

CombiBloc Close-coupled centrifugal pumps

CombiBloc Close-coupled centrifugal pumps CombiBloc Close-coupled centrifugal pumps CombiBloc CombiBloc is the premier solution for pumping clean thin liquids in a very cost-effective way. The pump is part of Johnson Pump s Combi-system, a modular

More information

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage - Liquid Ring Vacuum Pump One Stage LPH 60527 Pressure Range: Suction Range: 120 to 1013 mbar 200 to 800 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with

More information

SECTION STEAM CONDENSATE PUMPS

SECTION STEAM CONDENSATE PUMPS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 22 23 STEAM CONDENSATE PUMPS SPEC WRITER NOTES: 1. Delete between // ---- // if not applicable to project. Also delete any other item or paragraph not applicable

More information

CAP SERIES SEWAGE AND WASTE WATER PUMPS

CAP SERIES SEWAGE AND WASTE WATER PUMPS Part 8 CAP SERIES SEWAGE AND WASTE WATER PUMPS TECHNICAL SPECIFICATIONS : Turbosan CAP series consists of centrifugal sewage and waste water pumps. They are used for pumping muddy liquids like sewage and

More information

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256)

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256) CombiChem Centrifugal pumps according to ISO 5199 and ISO 2858 / EN 22858 (DIN 225) CombiChem No limits to reliability! CombiChem is Johnson Pump s solution for liquid transport in the chemical industry.

More information

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage - Liquid Ring Vacuum Pump One Stage LPH 50523 Pressure Range: Suction Range: 120 to 1013 mbar 70 to 500 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with

More information

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016 SECTION 23 21 23 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions and Division 01 Specification Sections, apply to this Section.

More information

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP WWPPCHLFT260 Instructions WWPPCHLFT260_Horizontal Multistage Centrifugal Pump_IB.indd 1 READ THIS MANUAL CAREFULL BEFORE INSTALL, START THE PUMP 1. Suction 2. Plug

More information

Cleaning System. Amajet. Type Series Booklet

Cleaning System. Amajet. Type Series Booklet Amajet Type Series Booklet Legal information/copyright Type Series Booklet Amajet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed

More information

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI Hydraulic Institute Standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) www.blowtech.in we make air move Blowtech Air Devices Pvt. Ltd. was founded in 1988 and quickly established

More information

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps Series 0 & FILE NO: d. DATE: June, 00 SUPERSEDES: d. DATE: July, 00 dualarm Vertical In-Line Pumps dualarm Smart pumps for the commercial HVAC market Vertical In-Line pump, the best design for HVAC systems,

More information

MARLOW PUMPS RECIRCULATION

MARLOW PUMPS RECIRCULATION End suction centrifugal pump line available in both close coupled and frame mounted configurations allow users to meet exactly most flow conditions on commercial pool and waterpark applications. Features

More information

TYPE VSM/VSMS VERTICAL SPACE MISER PUMPS

TYPE VSM/VSMS VERTICAL SPACE MISER PUMPS PACO VSM/VSMS TYPE VSM/VSMS VERTICAL SPACE MISER PUMPS Close and Split Coupled VERTICAL SPACE MISER Type VSM (Close Coupled) Type VSMS (Split Coupled) SMALL FOOTPRINT FOR TIGHT SPACES > Vertically mounted

More information

Pressure Boosting Solutions

Pressure Boosting Solutions GRUNDFOS Water Pressure Boosting Pressure Boosting Solutions 1 GRUNDFOS Water Pressure Boosting WHAT CAN CAUSE LOW WATER PRESSURE? Poor mains pressure Generally due to water companies reducing the supply

More information

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

4VH and 4VHX. 4 Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction 4VH and 4VHX 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction DURABLE MOTOR WILL DELIVER MANY YEARS OF RELIABLE SERVICE Oil-filled motor for maximum heat dissipation

More information

Specially Designed Waste Water & Sewage Pumps

Specially Designed Waste Water & Sewage Pumps Specially Designed Waste Water & Sewage Pumps Technical specifications Ebitt SC series consists of centrifugal sewage and waste water pumps. They are used for pumping muddy liquids like sewage and other

More information

W+ Pumps. Minimize Life Cycle Costs

W+ Pumps. Minimize Life Cycle Costs W+ Pumps Minimize Life Cycle Costs 2 7004-02-05-2010-GB Prepared for the future Designed for efficiency The W+ pump series is based on a unique hydraulic design which combines maximum efficiency with the

More information

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2 Cleaning unit for coolant :_decftez`_>r_fr] Book No.: 1271526-02 V2 Alfa Laval Separation AB Separator Manuals, dept. SKEL S-147 80 Tumba, Sweden Telephone: +46 8 53 06 50 00 Telefax: +46 8 53 03 10 40

More information

MCV - MCH - MCHZ Multistage pumps

MCV - MCH - MCHZ Multistage pumps MCV - MCH - MCHZ Multistage pumps You can put pressure on them! We offer you a range of reliable high-pressure multistage pumps. It includes a series of horizontal pumps, MCH and a series of vertical pumps,

More information

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Chemical Motor Pump Unit BN

Chemical Motor Pump Unit BN Operating & Maintenance Instructions BW 5 02 01 / 1 The operating instructions of the centrifugal pump and the accessories should be located close to the pump. These instructions should be read carefully

More information

CombiChem. Centrifugal pumps according to ISO 5199 and ISO 2858 / EN (DIN 24256)

CombiChem. Centrifugal pumps according to ISO 5199 and ISO 2858 / EN (DIN 24256) CombiChem Centrifugal pumps according to ISO 199 and ISO 88 / EN 88 (DIN 46) The SPX Johnson Pump Combi system is a modular programme of single stage CombiChem No limits to reliability! centrifugal pumps

More information

GRUNDFOS PRODUCT GUIDE. Unilift CC, KP, AP. Submersible wastewater pumps 60 Hz

GRUNDFOS PRODUCT GUIDE. Unilift CC, KP, AP. Submersible wastewater pumps 60 Hz GRUNDFOS PRODUCT GUIDE Submersible wastewater pumps 60 Hz Contents Mission Product overview, Unilift General data, Unilift Performance range 6 Applications 7 Type keys 8 Construction 9 Unilift CC Product

More information

Submersible. Pumps Motors. 50Hz 12 Submersible Pump. Pumping Solution

Submersible. Pumps Motors. 50Hz 12 Submersible Pump. Pumping Solution Submersible Pumps Motors 50Hz 2 Submersible Pump Pumping Solution 65 Product data 2 Submersible bore well pumps Construction Submersible motor & pumps for deep wells of 2 (DN 300 mm). Sized for connection

More information

EVMSU - Vertical Multistage Pumps. Product Catalog

EVMSU - Vertical Multistage Pumps. Product Catalog EVMSU - Vertical Multistage Pumps Product Catalog www.pumpsebara.com Built like a Kata a A Katana is a traditional Japanese sword made with distinctive, longstanding expertise started in 300 A.D. Katana

More information

CombiBloc. Close-coupled centrifugal pumps

CombiBloc. Close-coupled centrifugal pumps CombiBloc Close-coupled centrifugal pumps CombiBloc is the premier solution for pumping clean thin liquids in a very cost-effective way. The pump is part of SPX FLOW 's Johnson Pump brand Combi-system,

More information

Upompe Primeflo XP7 chemical self-priming centrifugal pumps

Upompe Primeflo XP7 chemical self-priming centrifugal pumps Upompe Primeflo XP7 chemical self-priming centrifugal pumps 1 Design Introduction: These Upompe Primeflo XP7 self-priming pump are heavy-duty design for rugged application and constructed to handle corrosive,

More information

1. Description INSTRUCTION FOR AIR BLAST COOLER TYPE COOL 450

1. Description INSTRUCTION FOR AIR BLAST COOLER TYPE COOL 450 1. Description General The cooler is used for cooling of water, oil or other liquid by use of air. The liquid is passing in the tubes where it transfere the energy to the air via the fins on the outside

More information

Technical Parameter: Suction Diameter: 40~250 mm Discharge Diameter: 25~200 mm

Technical Parameter: Suction Diameter: 40~250 mm Discharge Diameter: 25~200 mm HEGA Horizontal Multistage Pump Brief Introduction HEGAHorizontal Multistage Pump is the new multistage product series, the excellent hydraulic performance and structure of which have enabled low cost

More information

TYPE VL/VLS VERTICAL INLINE PUMPS

TYPE VL/VLS VERTICAL INLINE PUMPS PACO VL/VLS TYPE VL/VLS VERTICAL INLINE PUMPS Close or Split Coupled EXPERIENCE WHERE IT COUNTS Nothing speaks volumes more than the expertise of a company and their ability to continually provide high-quality,

More information

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components:

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components: Pumps DOE-HDBK-1018/1-93 CENTRIFUGAL PUMPS CENTRIFUGAL PUMPS Centrifugal pumps are the most common type of pumps found in DOE facilities. Centrifugal pumps enjoy widespread application partly due to their

More information

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage. LN series Horizontal Split Case Pumps Double Volute. Single Stage www.sterlingpumps.com.au LN series Sizes: 6 to 42 Capacity to 12,500 m³/h Heads to 190 metres A rugged, single stage, double volute horizontal

More information

Blockpumps. Vogel Series LSB. Lenntech. Tel Fax

Blockpumps. Vogel Series LSB. Lenntech. Tel Fax Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Blockpumps Vogel Series LSB WITH HYDRAULICS ACCORDING TO ISO 2858 Technical Data Performance: m Capacity up to 450m

More information

2CP DATA SHEET. Horizontal Two Stage Centrifugal Pumps 2CP 32/210B 2CP 32/200B 2CP 32/200C

2CP DATA SHEET. Horizontal Two Stage Centrifugal Pumps 2CP 32/210B 2CP 32/200B 2CP 32/200C MADE IN ITALY DATA SHEET Horizontal Two Stage Centrifugal Pumps 2CP 20 2CP 32/20A 00 2CP 32/20B 80 2CP 32/200B HEAD [m] 60 2CP 32/200C 40 20 0 2 4 6 8 0 2 4 6 3 FLOW [m /hr] Linz Electric is a brand of

More information

KUBOTA Double suction volute pump

KUBOTA Double suction volute pump PUMPS CATALOGUE KUBOTA Double suction volute pump DV-L type J series KUBOTA Corporation DOMESTIC OFFICES AND OVERSEAS OFFICE E-Mail:pump@kubota.co.jp http://www.kubota.co.jp/english KUBOTA Double suction

More information

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. In-Line Pumps IIL / IVP / IVP-CC

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. In-Line Pumps IIL / IVP / IVP-CC N N O V A T I O N E F F I C I E N C Y Q U A L I T Y In-Line Pumps IIL / IVP / IVP-CC For more than 0 years the name Ruhrpumpen TM has been synonymous worldwide with innovation and reliability for pumping

More information

1. Description INSTRUCTION FOR BLAST COOLER TYPE COOL 250. Material

1. Description INSTRUCTION FOR BLAST COOLER TYPE COOL 250. Material 1. Description General The cooler is used for cooling of water, oil or other liquid by use of air. The liquid is passing in the tubes where it transfere the energy to the air via the fins on the outside

More information

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800 KQ Series Multistage Booster Pump System Installation Manual KQ200/400 KQ800 ISO 9001 Certified Description The KQ series booster pump is an all-in-one compact and reliable automatic multistage centrifugal

More information

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 Building Services Piping. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Full-line Product Overview

Full-line Product Overview Full-line Product Overview End Suction Centrifugal Pumps This general purpose pump can be configured in frame-mounted and close-coupled, semi-open and enclosed impeller configurations. They are available

More information

The Fristam FDS double-screw pump

The Fristam FDS double-screw pump Fristam FDS The Fristam FDS double-screw pump By developing this exceptional pump, we intended to set new standards in double-screw technology. We started by rethinking the technical and functional principles

More information

Pump technology: Improved energy efficiency in refrigeration plants. Dr. R. Krämer

Pump technology: Improved energy efficiency in refrigeration plants. Dr. R. Krämer Technical Report Improved energy efficiency in refrigeration plants According to the European EDL directive (final energy efficiency and energy services), 9 % energy savings over a nine-year-period in

More information

Pumps Motors ISO 9001 Company

Pumps Motors ISO 9001 Company DT OOKLET Hz Pumps Motors ISO ompany Pumping Solution ontents Product data Introduction pplications Features and benefits Type key Operating conditions Other versions on request Function LE ontroller for

More information

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR General DICKOW-pumps of series HZ/HZA are single- or multistage centrifugal pumps with shaft sealing. Application HZ/HZA-pumps are applied

More information

Engine Room Pumps. Model C2G. Pump Systems

Engine Room Pumps. Model C2G. Pump Systems Engine Room Pumps Model C2G Pump Systems C2G centrifugal pumps Hamworthy has more than 100 years experience in design and manufacturing of centrifugal pumps for the marine industry. Following the great

More information

Horizontal Split Case Pumps Type U

Horizontal Split Case Pumps Type U Horizontal Split Case Pumps Type U 7.1 7.2 Stage U Type Pumps Features: Axially Split Case Design Range from 20M 3 /Hr to 600M 3 /Hr Two Stage Pump Single Suction Twin Volute Casing Design Closed type

More information

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS MCF 00 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS MCF 00 CENTRIFUGAL FAN FOR COMBUSTIBLE GASES MCF 00 centrifugal fan for biogas, natural gas or combustible gases, in conformity to the

More information

Stainless steel centrifugal pumps

Stainless steel centrifugal pumps Stainless steel centrifugal pumps FOR GENERAL AND PROCESSING INDUSTRIES ICP IFF IRP ISP For over 25 years the ICP2 pump has proven itself as a very reliable process pump in the general processing industries.

More information

CombiPrime Self-priming centrifugal pumps

CombiPrime Self-priming centrifugal pumps CombiPrime Self-priming centrifugal pumps CombiPrime Self-priming centrifugal pumps CombiPrime is a series of self-priming centrifugal pumps, suited for pumping clean or slightly polluted liquids, with

More information

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions GRUNDFOS INSTRUCTIONS Sololift2 C-3 Installation and operating instructions English (US) English (US) Installation and operating instructions Original installation and operating instructions. CONTENTS

More information

Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Germany VM_e.pdf - 18.05.08 Page 1/6 Oil burners fuel unit with solenoid valve

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS PART 0 A/E INSTRUCTIONS 0.01 Design Requirements A. Pumping system design 1. A primary-secondary pumping system is preferred. Redundant pipes are required for chillers and boilers. 2. Select pumps to operate

More information

Vogel Pumpen. Vogel Pumpen. Vogel - Blockpumps. Design LMN / LM

Vogel Pumpen. Vogel Pumpen. Vogel - Blockpumps. Design LMN / LM Vogel Pumpen Vogel - Blockpumps Design LMN / LM 1 Materials: Design LMN, Sizes DN 32-80 Design LM, Sizes DN 100-150 Performance: Capacity up to 500 m 3 /h (2200 USgpm) Head up to 95 m (312 feet) Speed

More information

Water engineers and utilities are often

Water engineers and utilities are often FWRJ Horizontal or Vertical? High-Service Pump Selection Mark Ludwigson, Len Rago, and Jeff Greenfield Water engineers and utilities are often faced with a decision concerning the best type of pump when

More information

Transformer oil coolers BETA & CETA

Transformer oil coolers BETA & CETA 2012.1 Transformer oil coolers BETA & CETA Transformer oil coolers BETA & CETA Luvata is pleased to present to the market its renewed transformer oil coolers. The BETA and CETA series of transformer oil

More information

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1 A AD Oil burners fuel unit deltapumps.com DE116-0709 A-AD_en_0709.pdf - 16.11.09 Page 1/1 Oil burners fuel unit Type A, AD 1- Applications The DELTA aluminium fuel unit type A is an efficient and modern

More information

Block Macerators Series ABM-2-S

Block Macerators Series ABM-2-S Block Macerators Series ABM-2-S Usage Macerators chop solids conveyed in liquids; materials like wood, textiles, plastics, paper, rubber, bones, skins, glass etc., so that they may be pumped. After treatment

More information

QUALITY PRODUCTS, INC. OIL-TO-AIR HEAT EXCHANGERS

QUALITY PRODUCTS, INC. OIL-TO-AIR HEAT EXCHANGERS OIL-TO-AIR HEAT EXCHANGERS Description BUCR Series Oil-To-Air Heat Exchangers 1 BUCR Series Oil-To-Air Heat Exchangers He The BUCR Series heat exchangers are designed to stabilize the oil temperature and

More information

PENGUIN SERIES HSC PUMPS INTRODUCTION

PENGUIN SERIES HSC PUMPS INTRODUCTION PENGUIN Installation & Maintenance SERIES HSC PUMPS MODELS HSC-1/4 HSC-1/2 HSC-3/4 HSC-1 HSC-2 HSC-3 SEALS S - Single D - Double M - Single/Multi-Stage INTRODUCTION Penguin 316 stainless steel centrifugal

More information

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. Open Impeller ASME (ANSI) B73.1 Pump for continuous use in Chemical Process Services

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. Open Impeller ASME (ANSI) B73.1 Pump for continuous use in Chemical Process Services N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO Open Impeller ASME (ANSI) B73.1 Pump for continuous use in Chemical Process Services Horizontal Split Case For more than 6 years the name Ruhrpumpen

More information

Wash and Clean By Michael Rasmussen, Industry application team, Grundfos, Denmark

Wash and Clean By Michael Rasmussen, Industry application team, Grundfos, Denmark Wash and Clean By Michael Rasmussen, Industry application team, Grundfos, Denmark Introduction Wash & Clean systems for the food processing industry is an utility application that sets high requirements

More information

SECTION STEAM CONDENSATE PUMPS

SECTION STEAM CONDENSATE PUMPS SECTION 23 22 23 STEAM CONDENSATE PUMPS PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable in the

More information