1 Solution builder in energy management

2 Catalog of products 1 COMPANY PROFILE 2 HTHW (High Temperature Hot Water) GENERATOR 3 AQT - WATERTUBE STEAM BOILER 4 AQT - WATERTUBE HOT WATER HEATER 5 AQT HEATER - GLYCOL/THERMAL FLUID 6 BIOMASS FUEL / Hybrid Boiler Steam and Hot Water / D, A-Type 7 WASTE HEAT RECOVERY BOILER 8 PACKAGED A-TYPE 9 PACKAGED D-TYPE 10 PACKAGED O-TYPE 11 DEAERATOR / CONDENSATE / FEED WATER SYSTEM 12 CUSTOM DESIGNED VESSELS & SUPERHEATERS

3 1 Catalog of products COMPANY PROFILE >>

4 Solution builder in energy management ent Solution builder in energy management Nancy Simoneau president Innovation The bold innovation of Groupe Simoneau has made the company a global thought leader in the conception, assembly and installation of industrial, institutional and commercial high-efficiency boilers. We custom build energy efficient solutions, according to the specific needs of our clients. Customer service Innovation is not the only reason of our success. Our outstanding customer service is an integral part of our reputation. We believe that a frank and honest business relation based on mutual respect, authenticity and communication is essential to our success. Our customers and business partners can always count on these three values when they deal with Groupe Simoneau. Simoneau Employees Over the years, we could not have become a world-class leader in the design and construction of boilers and high-pressure vessels if it wasn t for the contribution of our most important resource; our employees. At Groupe Simoneau, we like to work with dedicated and creative people who contribute to the development and reputation of our company by their knowledge and experience. Success in the Market Place After more than 30 years in business; innovation, customer service and the respect of our business partners is still what drives us today. With these values strongly entrenched, we look forward and work relentlessly to offer energy efficient solutions that respect the highest environmental standards while satisfying our customers needs. Sincerely, Nancy Simoneau President eau.com

5 Solution builder in energy management ent Solution builder in energy management Beyond our products, there is an experienced team dedicated to reduce the level of energy consumption in our society. eau.com

6 Catalog of products 1 2 HTHW (High Temperature Hot Water) GENERATOR >>

7 Solution builder in energy management HTHW Generator Simoneau High temperature Hot Water Generator The Simoneau HTHW generator is a header to header type design with gas-tight, welded steel intercasing, water cooled rear wall, staggered bent tube convection section, ceramic wool front wall and optional integrated finned tube economizer. Simoneau s generator is specially design for hot water medium temperature/high temperature/high pressure. Typical applications include central heating plants, airports, hospitals, universities, processing facilities and many others. The Simoneau HTHW generator is specifically designed to generate high/medium temperature hot water. The Simoneau design provides the next generation, Best of Class heat tranfer technology. Our HTHW design is a significant improvement over the competition s 50 year old technology. Simoneau s HTHW Generator Design Features: Capacities: up to 75 MMBTU / HR. Design pressures: up to 500 psig. Temperature up to 400 F. Our genarator can handle very high temperature differential. Two pass flue gas contact with staggered tube arrangement for maximum heat transfer. Balanced heat transfer prevents thermal shock. Operates with natural gas, #2 oil and alternative gases. Meets or exceeds NOx Emission Standards while providing high turndown ratio. Optional integrated economizer available on most capacities and applications. P-HTHW-1_291110

8 Simoneau HTHW Generator High temperature Hot Water Generator Benefits of Simoneau s HTHW Generator Design: High efficiency provides significant fuel savings. Provides quick ramp up time. Operating and maintenance costs are the lowest on the market. Ease of installation and more economical to install. Wide range of capacities and excellent long-term reliability to meet institutional, industrial and commercial applications. Generator system components (burner, controls and emissions options) designed specifically to provide ease of operation. Boiler system components (burner, controls, economizer, and emissions options) designed specifically to provide ease of operation. Le Groupe Simoneau provides a customized packaged unit per your needs. We can provide the complete package of controls, instrumentation and burner. At your option, we can supply any degree of packaging you may require. Why Simoneau: As a Solution Builder in Energy Management, Simoneau utilizes its technical expertise (most qualified engineering team in the industry) and quality manufacturing to provide custom solutions for your specific boiler applications. Reliability, efficiency and the safety of its boiler systems are key results of the Simoneau designs. Our integration of technical expertise, quality manufacturing, on-time delivery and field support makes Simoneau your partner of choice. To learn more about Simoneau and its products, please contact: Represented by: LE GROUPE SIMONEAU INC De Coulomb Street Boucherville (Québec) J4B 8C5 P F info@groupesimoneau.com P-HTHW-2_291110

9 HTHW Type High Temperature Hot Water Generator 1 High temperature Hot Water Generators are registred under ASME Code Section I for operation up to 500 PSIG & 450 ºF. Ø" D " GAS OUTLET BAFFLE WATER OUTLET BURNER " C " GAS OUTLET SIMONEAU OBSERVATION PORT WATER INLET ACCESS DOOR " B " DRAINS FOR EACH PASS " A " 1 1/2 " NPT BLOW-OFF Services Services Services Boiler Model Number Capacity MMBTU / hr A Length B Width C Height D Gaz Outlet Dry WEIGHTS (in Pounds) HTHW-100 3, / /16 12 dia. 7,200 8,250 HTHW-125 4, / /16 16 dia. 7,750 9,000 HTHW-150 5, / /16 16 dia. 8,750 10,000 HTHW-175 5, /16 18 dia. 9,250 10,750 HTHW-200 6, / /16 18 dia. 10,250 12,000 HTHW-250 8, /16 20 dia. 12,250 14,500 HTHW , / /16 20 dia. 13,250 15,500 HTHW , /16 20 dia. 14,250 16,750 HTHW , / /16 24 dia. 17,250 20,500 HTHW , / /16 24 dia. 18,000 21,250 HTHW , / /16 24 dia. 19,250 23,000 HTHW , / /8 30 dia. 23,500 28,250 HTHW , / /8 32 dia. 25,750 31,250 HTHW , / /8 32 dia. 28,040 29,750 HTHW , / /8 32 dia. 29,750 36,000 HTHW , / /4 36 dia. 35,000 43,250 HTHW , / /4 36 dia. 36,500 45,000 HTHW , / /4 36 dia. 37,850 46,850 HTHW , / / dia. 40,900 51,400 Capacities up to 2000 HP available upon request. All dimensions are imperial. Flooded DS-HTHW-1_211210

10 HTHW Type High Temperature Hot Water Generator 2 Typical High Temperature Hot Water Generator DS-HTHW-2_ DESIGNED BY OUR ENGINEERING TEAM: 1541 De Coulomb Street Boucherville (Québec) J4B 8C5 P F info@groupesimoneau.com Solution builder in energy management

11 TYPICAL SPECIFICATIONS PACKAGED AQUATUBE HEATERS HIGH TEMPERATURE HOT WATER GENERATOR Project Reference: Fabricated as per ASME Section 1 1

12 1. APPLICATION REQUIREMENTS High Temperature Hot Water Generator Model: HTHW Rated Heater Output: MBTU/hr Design Pressure: psig Operating Temperature supply: F assumed Operating Temperature return: F assumed ASME Code Section: I Dimensions: o Length: o Width: o Height: Available Gas Pressure: psig Burner Model: Rated Input: MMBTU/hr natural gas MMBTU/hr #2 oil Power Supply: / / 2. GENERAL GENERATOR REQUIREMENTS Provide a high temperature hot water generator(s) shop of the packaged flexible steel water tube design. The generator(s) will be designed for pressurized firing, complete with a heavy structural steel base, trim, burner, burner controls and appurtenances. The generator(s) will be shop hydrostatic tested, inspected and stamped by a recognized government inspector in accordance with ASME Code Section I. As a complete factory assembled package, the generator(s) shall be ready for the attachment of water, fuel, drain, electrical, stack and venting connections. The hot water generator(s) specified herein shall be designed to produce ( ) MMBTU/hour continuously at F outlet temperature and F return temperature. All pressure containing parts, accessories, fixtures and fittings shall be designed and constructed for psig design pressure, in accordance with the latest edition of the applicable ASME Code Section I. The generator(s) will be furnished as a complete factory assembled unit, consisting of the pressure vessel assembly, burner, fuel trains, combustion and flame safeguard controls. 3. ACCEPTABLE EQUIPMENT The packaged hot water generator shall be an AQUATUBE Balanced Flow heater design. 2

13 4. GENERATOR DESIGN The generator shall be a steel flexible water tube of the two drum of O type design. The furnace and convection passes shall consist of tangent tubes on both sides of the furnace forming a symmetrical and straggered layout, assuring a balanced flow circulation pattern under all load conditions. The design will provide longitudinal gas passes separated with staggered water wall tubes to provide turbulent gas flow and maximize heat transfer. The generator rear wall shall be constructed of a full membrane water tube configuration for all generators over 80 HP to provide high efficiency, cooling of combustion gases and increased heat transfer. No refractory will be used in the target wall area, except around the access door. All generator tubes will be a minimum of 1.5 inches in diameter, inch minimum wall thickness for the boiler from 20 to 1200 HP and be easily accessible for individual replacement. To ensure positive circulation of water, the heater will be designed with baffles in headers in order to increase velocity of water, and integral orifices in downcomer tubes to insure equal repartition in each tube and prevent steaming and steam plug. A dedicated generator tube will be incorporated in the design to permit any entrained air at the top of the lower header to pass freely into the upper header. Hole drilled at top of baffles in headers will insure the same. The combustion chamber construction will consist of water tubes strength welded to headers on both sides, floor and roof. The front wall will be constructed of ceramic fibre blocks rated at 2400 F. The rear target wall will be water cooled without the use of any refractory except on the boilers from 20 to 80 HP where it will be like the front wall. The inner casing s will be fabricated of 11 gauge steel overlaid with a 2 inch thick insulation rated at 2300 F. This casing will be seal welded construction and will be designed to contain the products of combustion at the maximum operating furnace pressure. The outer casings shall consist of 14 gauge corrugated pre-painted steel panels, underlain with 2 inch fibreglass blanket insulation. There will be an adequate air space between inner and outer casings to assist in insulation. Top is made of checker plates. The furnace shall be accessible from the rear with a double man door, headers will be provided with hand holes. Observation ports will be provided for viewing the combustion conditions. The exhaust gas vent connection will be located at the front top center line of the generator and at the back for heater for 80 HP and less. Rear connection for heaters 100 HP and more is available as an option. 3

14 Lifting lugs shall be furnished on the heater top header, to facilitate rigging and lifting of the unit. 5. GENERATOR TRIM AND CONNECTIONS A flanged hot water supply connection will be located on the center line at the front of the upper and lower headers. A generator water drain connection will be provided at the rear of the lower header. An air vent connection will be provided on the center line of the upper header. Safety relief valve(s) in compliance with ASME code will be furnished. A generator water temperature gauge will be provided. A manual drain valve will be provided. Hot water temperature controls will be provided for operation, high limit (auto reset) and high/high limit (manual reset). Probe type main and auxiliary low water cut off control will be furnished as an integral part of the generator upper header connection. 4

15 Catalog of products AQT - WATERTUBE STEAM BOILER >>

16 Solution builder in energy management AQT Watertube Steam Boiler The AQT watertube is an O-type construction with gas-tight, welded steel intercasing, water cooled rear wall, staggered bent tube convection section, ceramic wool front wall and optional integrated finned tube economizer. Simoneau s AQT watertube applications include high & low pressure steam. Typical industries include manufacturing & processing facilities, pulp & paper,petrochemical, pharmaceuticals, hospitals, universities and ethanol plants. Simoneau s AQT Design Features: Capacities: 100 BHP to 2,000 BHP (70,000 PPH). Design pressures: 15 psig to 650 psig. Optional radiant/connective super heater. Radiant & convective type superheaters with temperatures up to 750 ºF. Three pass flue gas contact with staggerred tube arrangement for maximum heat transfer. Balanced heat transfer prevents thermal shock. Superior steam quality (1 ppm) using proprietary separation technology with a large steam drum. Operates with natural gas, #2 oil and alternative gases. Meets or exceeds NOx Emission Standards while providing high turndown ratio. Natural boiler water circulation eliminating the need for a circulating pump. Integrated economizer provides efficiency to 85% firing natural gas. P-AQTWSB-1_291110

17 AQT - Watertube Steam Boiler Benefits of Simoneau s AQT Steam Boiler Design: High efficiency provides significant fuel savings. Minimizes installation and maintenance costs. Reliable source of high quality, dry, saturated steam up to 1 ppm. Extensive capacity range and excellent long-term reliability to meet commercial, industrial and institutional applications. Provides quick load response. Low operating and reduced maintenance costs. Boiler system components (burner, controls, economizer, and emissions options) designed specifically to provide ease of operation. Le Groupe Simoneau provides a customized packaged unit per your needs. We can provide the complete package of controls, instrumentation and burner. If you prefer, we can supply any degree of packaging you may require. Why Simoneau: As a Solution Builder in Energy Management, Simoneau utilizes its technical expertise (most qualified engineering team in the industry) and quality manufacturing to provide custom solutions for your specific boiler applications. Reliability, efficiency and the safety of its boiler systems are key results of the Simoneau designs. Our integration of technical expertise, quality manufacturing, on-time delivery and field support makes Simoneau your partner of choice. To learn more about Simoneau and its products, please contact: Represented by: LE GROUPE SIMONEAU INC De Coulomb Street Boucherville (Québec) J4B 8C5 P F info@groupesimoneau.com P-AQTWSB-2_291110

18 AQT Watertube Steam Boiler Model 100 HP to 1200 HP with an integrated economizer 1 Our integrated economizers allow a 85 % thermal efficiency (HHV) with natural gas Economizer front view This boiler is recognised by CSA Canada as a 85% energy efficient boiler and is therefore elegible to financial help. Front right view Note:The claimed efficiency of 85% is based on operation at 125psig and a feedwater temperature of 180 ºF. Boiler Model Number DIMENSIONS FOR AQUATUBE HIGH AND LOW STEAM BOILERS FROM 100HP TO 600HP Capacity # / hr A Length B Width C Height D Gas Outlet Dry WEIGHTS (in Pounds) AQT-100Hie 3, / /8 12 dia. 8,700 9,900 AQT-125Hie 4, /8 16 dia. 9,250 10,575 AQT-150Hie 5, /8 16 dia. 10,375 11,900 AQT-175Hie 6, /8 18 dia. 11,225 12,900 AQT-200Hie 6, / /8 18 dia. 12,350 14,250 AQT-250Hie 8, /2 20 dia. 14,385 16,680 AQT-300Hie 10, / /2 20 dia. 15,400 17,900 AQT-350Hie 12, /2 24 dia. 16,675 19,425 AQT-400Hie 13, /2 24 dia. 20,225 23,700 AQT-450Hie 15, /2 24 dia. 21,050 24,700 AQT-500Hie 17, / /2 24 dia. 22,625 26,600 AQT-600Hie 20, /4 30 dia. 28,200 29,625 AQT-700Hie 24, / /4 32 dia. 35,600 45,500 AQT-800Hie 27, / /4 32 dia. 38,800 50,000 AQT-900Hie 31, /4 32 dia. 41,000 53,000 AQT-1000Hie 34, /8 36 dia. 47,000 62,750 AQT-1100Hie 37, /8 36 dia. 48,500 65,000 AQT-1200Hie 41, /8 36 dia. 53,200 71,000 Flooded DS-AQTSB-1_161210

19 AQT Watertube Steam Boiler Model 100 HP to 1200 HP with an integrated economizer 2 Typical AQT-600 Hie natural gas fired with integral type economizer Boiler rear view Water inlet Economizer Tube bundle Water inlet Boiler front view DS-AQTSB-2_ DESIGNED BY OUR ENGINEERING TEAM: 1541 De Coulomb Street Boucherville (Québec) J4B 8C5 P F info@groupesimoneau.com Solution builder in energy management

20 AQT Watertube Steam Boiler Model 100 HP to 1200 HP 1 Front right view Boiler Model Number DIMENSIONS FOR AQUATUBE HIGH AND LOW STEAM BOILERS FROM 100HP TO 600HP Capacity # / hr A Length B Width C Height D Gas Outlet WEIGHTS (in Pounds) AQT-100H 3, / /8 12 dia. 8,700 9,900 AQT-125H 4, /8 16 dia. 9,250 10,575 AQT-150H 5, /8 16 dia. 10,375 11,900 AQT-175H 6, /8 18 dia. 11,225 12,900 AQT-200H 6, / /8 18 dia. 12,350 14,250 AQT-250H 8, /2 20 dia. 14,385 16,680 AQT-300H 10, / /2 20 dia. 15,400 17,900 AQT-350H 12, /2 24 dia. 16,675 19,425 AQT-400H 13, /2 24 dia. 20,225 23,700 AQT-450H 15, /2 24 dia. 21,050 24,700 AQT-500H 17, / /2 24 dia. 22,625 26,600 AQT-600H 20, /4 30 dia. 28,200 29,625 AQT-700H 24, / /4 32 dia. 35,600 45,500 AQT-800H 27, / /4 32 dia. 38,800 50,000 AQT-900H 31, /4 32 dia. 41,000 53,000 AQT-1000H 34, /8 36 dia. 47,000 62,750 AQT-1100H 37, /8 36 dia. 48,500 65,000 AQT-1200H 41, /8 36 dia. 53,200 71,000 Dry Flooded DS-AQTSB-sans-1_161210

21 AQT Watertube Steam Boiler Model 100 HP to 1200 HP 2 Typical AQT-600 Hie natural gas fired with integral type economizer DS-AQTSB-sans-2_ DESIGNED BY OUR ENGINEERING TEAM: 1541 De Coulomb Street Boucherville (Québec) J4B 8C5 P F info@groupesimoneau.com Solution builder in energy management

22 Solution builder in energy management Low Water Volume AQT Boiler Series Our revolutionary Low Water Volume Boiler, the Thermodesign AQT Series, is designed to bring industrial capacity to steam generation without loss in efficiency and capacity. With the involvement of Thermodesign, Simoneau Group brings to the market this innovative design offering the highest fuel efficiency ratings and the lowest energy consumption in the industry. The AQT Series also increases the potential to install larger capacity generating plants up to 1500 BHP without the need of operating engineers. Simoneau s Low Water Volume AQT Boiler Series Design Features: Boiler horse power ratings from 100 to 600 BHP TSSA and ASME approval Meets and exceeds NOx Emission Standards Three Pass Flue Gas contact with staggered tube arrangement for maximum heat transfer Integrated economizer giving 85% efficiency with 180 F feed water and at 200 psig Reduced radiation loss, using a unique wet back design and double insulation on side walls. High turndown ratio, from 4:1 to 8:1, reducing purge loss. Superior steam quality using proprietary steam separation technology together with a large steam drum. Natural boiler water circulation eliminating the need for a circulating pump. Balanced heat transfer preventing thermal shock. Integrated economizer provides efficiency to 85% firing natural gas. P-LWV-1_031210

23 Low Water - Volume AQT Boiler Series Benefits of Simoneau s Low Water Volume AQT Boiler Series Design: Very fast response time from cold start to steam in less than 5 minutes. Reliable source of high quality 99.5% dry saturated steam with greater steam reserve in our larger drum. Under many load conditions, this can be critical in many operations, eliminating the need for operating engineers. The highest fuel and electrical cost savings in the industry. State of the art design and quality manufacturing provides peace of mind to our clients for years of strong reliability, stable operating and reduced maintenance costs. Extended warranties among the best in the market (thermal shock 20 years, pressure vessel 10 years). Simoneau Group will provide boiler predicted performances prior to the purchase of a Low Water Volume Boiler. This will allow customers to compare our improved efficiencies with competitive alternatives. Purchase incentives offered by Regional Gas Utility Companies (where applicable). Why Simoneau: As a Solution Builder in Energy Management, Simoneau utilizes its technical expertise (most qualified engineering team in the industry) and quality manufacturing to provide custom solutions for your specific boiler applications. Reliability, efficiency and the safety of its boiler systems are key results of the Simoneau designs. Our integration of technical expertise, quality manufacturing, on-time delivery and field support makes Simoneau your partner of choice. To learn more about Simoneau and its products, please contact: Represented by: LE GROUPE SIMONEAU INC De Coulomb Street Boucherville (Québec) J4B 8C5 P F info@groupesimoneau.com P-LWV-2_031210

24 AQT High Efficiency Low Water Volume Steam Boiler Thermodesign AQT-100 HLV to AQT-600 HLV 1 85 % energy efficient approved low water volume boiler Top view Front view Side view Rear view Note 1: This boiler is labelled Low Volume and meets Ontario s Operating Enineers ACT regulation 219/01 for unattended operation for up to 600 HP high pressure steam. Note 2: This boiler is labelled Low Volume and meets Manitoba s Operating Enineers ACT regulation 116/2003 for unattended operation for up to 300 HP for low and high pressure steam. The claimed efficiency of 85% is based on the HHV of natural gas and operation at 125 psig with a feedwater temperature of 180 ºF. Performance with other operation conditions available on request. Boiler Model Number Capacity * / hr A Length B Width C Height to Steam Outlet D Height to Gaz Outlet E Steam Outlet F2 Gas Outlet Rear WEIGHTS (in Pounds) AQT-100HLV 3, / / # 12 dia. 9,000 10,750 AQT-125HLV 4, / / # 16 dia. 9,500 11,500 AQT-150HLV 5, / / # 16 dia. 10,500 13,000 AQT-175HLV 6, / / # 18 dia. 11,250 13,750 AQT-200HLV 6, / / # 18 dia. 12,250 15,250 AQT-250HLV 8, / # 20 dia. 15,000 18,750 AQT-300HLV 10, / # 20 dia. 15,750 20,000 AQT-350HLV 12, / # 24 dia. 17,000 21,500 AQT-400HLV 13, / # 24 dia. 21,000 26,500 AQT-450HLV 15, / # 24 dia. 21,750 27,500 AQT-500HLV 17, / # 24 dia. 23,250 30,500 AQT-600HLV 20, / # 24 dia. 23,250 30,500 All dimensions are imperial. Because of continuous improvement efforts, this information is subject to change without notice. Dry Flooded DS_LWV-1_071210

25 AQT High Efficiency Low Water Volume Steam Boiler Thermodesign AQT-100 HLV to AQT-600 HLV 2 Typical AQT Low Volume boiler DS_LWV-2_ DESIGNED BY OUR ENGINEERING TEAM: 1541 De Coulomb Street Boucherville (Québec) J4B 8C5 P F info@groupesimoneau.com Solution builder in energy management

26 TYPICAL SPECIFICATIONS PACKAGED AQUATUBE BOILER HIGH PRESSURE STEAM WITH INTEGRATED ECONOMIZER Project Reference: Fabricated as per ASME Section 1 for High Pressure Steam 1

27 1. APPLICATION REQUIREMENTS Aquatube Watertube Steam Boiler Model: AQT Rated Boiler Output: PPH Design Pressure: psig Operating Pressure: psig ASME Code Section: I Available Gas Pressure: psig Burner Model: M.M. Controller: Rated Input: MMBTU/hr Power Supply: / / 2. GENERAL BOILER REQUIREMENTS Provide a steam boiler(s) shop assembled of the packaged flexible steel water tube design. The boiler(s) will be designed for pressurized firing, complete with a heavy structural steel base, trim, burner, burner controls and appurtenances. The boiler(s) will be shop hydrostatic tested, inspected and stamped by a recognized government inspector in accordance with ASME Code Section I. As a complete factory assembled package, the boiler(s) shall be ready for the attachment of water, fuel, drain, electrical, stack and venting connections. The steam boiler(s) specified herein shall be designed to produce pounds of steam per hour continuously at psig operating pressure with a supply water temperature of F. All pressure containing parts, accessories, fixtures and fittings shall be designed and constructed for psig design pressure, in accordance with the latest edition of the applicable ASME Code Section I. The boiler(s) will be furnished as a complete factory assembled unit, consisting of the pressure vessel assembly, burner, fuel trains, combustion and flame safeguard controls. 3. ACCEPTABLE EQUIPMENT The packaged steam boiler shall be an AQUATUBE Balanced Flow boiler design. 4. HEATER DESIGN The boiler shall be a steel flexible water tube of the two drum of O type design. The furnace and convection passes shall consist of tangent tubes on both sides of the furnace forming a symmetrical and straggered layout, assuring a balanced flow circulation pattern under all load conditions. 2

28 The design will provide longitudinal gas passes separated with staggered water wall tubes to provide turbulent gas flow and maximize heat transfer. The boiler rear wall shall be constructed of a full membrane water tube configuration for all boilers over 80 HP to provide high efficiency, cooling of combustion gases and increased heat transfer. No refractory will be used in the target wall area. All boiler tubes will be a minimum of 1.5 inches in diameter, inch wall thickness for the boiler from 20 to 200 HP and 1.50 inches in diameter, inch wall thickness for the boiler from 250 to 2000 HP and be easily accessible for individual replacement. To ensure positive circulation of water, the boiler will be designed with dual downcomers, two at the front and two at the rear. Downcomers will be external to the heat zone and provide natural circulation without dependence on external pump. The downcomers will be isolated and not considered a part of the boiler heating surface. No site insulation of downcomers will be required, downcomers will be incorporated into the casing design, fully insulated and not be exposed to operating personnel. A dedicated boiler tube will be incorporated in the design to permit any entrained air at the top of the lower drum to pass freely into the upper drum. The combustion chamber construction will consist of water tubes on both sides, floor and roof. The front wall will be constructed of ceramic fibre board rated at 2900 F. The rear target wall will be water cooled without the use of any refractory except on the boilers from 20 to 80 HP where it will be like the front wall. The inner casings will be fabricated of 11 gauge steel overlaid with a 2 inch thick insulation rated at 2300 F. This casing will be seal welded construction to and will be designed to contain the products of combustion at the maximum operating furnace pressure. The outer casings shall consist of 14 gauge corrugated pre-painted steel panels, underlain with 2 inch fibreglass blanket insulation. There will be an adequate air space between inner and outer casings to assist in insulation. The furnace shall be accessible from the rear with a double man door, drums will be provided with hand holes and man ways. Observation ports will be provided for viewing the combustion conditions. The exhaust gas vent connection will be located at the front top center line of the boiler. Lifting lugs shall be furnished on the boiler, to facilitate rigging and lifting of the unit. 5. ECONOMIZER DESIGN Tubes bundle is laid horizontally on both side of the upper header and flue gas flow in a cross flow manner between baffles. 3

29 The economizer is integrated to the boiler in order to minimize piping and heat loss. The heating surface will be made of 2½, 2 or 1½ diameter tubes with about 5 segmented fins per inch to meet the required performances. High frequency welded fins are made of steel thickness and the height will not be more than They will be continuously high frequency welded to the tubes. The arrangement of the tubes will be staggered. The heating surface is made of 2½, 2 or 1½ diameter tubes featuring about 4 or 5 fins per inch depending of the required performances. High frequency welded fins are made of steel thick and no more than high. Tubes arrangement is staggered. The tubes will be in SA-178A, ERW or seamless and will be thick or more. The tubes will be connected to the water inlet of the steam drum. These will be of steel pipe in SA-53B ERW of a minimum thickness required by the ASME code for the pressure and temperature. The seal welded casing allows a free circulation of flue gases to reduce corrosion. It is fabricated of steel plate. The economizer will be fully insulated so that the external casing temperature will not exceed 40 F above ambient temperature. External casing is covered with corrugated panels in the continuity of the boiler sides. 6. BOILER TRIMS AND CONNECTIONS Flanged steam supply connection from 3 diameter and over will be located on the center line at the front of the upper steam drum. A boiler water blow off connection will be provided at the rear of the lower drum. An air vent connection will be provided on the center line of the steam drum. A surface blow off connection will be provided at the bottom of the steam drum. Opposed feed water and chemical feed connections will be provided at the rear of the steam drum to ensure complete mixing of water and chemical on entry to the boiler. Safety relief valve(s) in compliance with ASME code will be furnished. A probe type low water cut off control will be furnished as an integral part of the boiler water column. A water column/gauge glass will be mounted near the steam drum outlet connection and will provide a visual indication of the actual water level in the drum. The water column shall include the water level electrodes for low water and will include try cocks (if required), drain valve for the water column and gauge glass. 4

30 Steam pressure controls will be provided for operation, high limit (auto reset) and high/high limit (manual reset). A separate probe type, manual reset control will be provided for auxiliary low water cut off. Provide a steam pressure gauge. Provide a single element feed water control system to monitor and automatically adjust feed water flow rates proportionately in accordance with drum level. This system will be supplied complete with a drum mounted level transmitter (or controller) and will signal a modulating feed water valve (on-off feed water valve for boilers up to 300 HP) through a valve mounted actuator to allow the correct water flow to the boiler in compliance with the plant load demand. Quick and slow opening manual blow down valves will be provided. A continuous surface blow down valve will be provided. 5

31 Catalog of products AQT - WATERTUBE HOT WATER HEATER >>

32 Solution builder in energy management AQT - Watertube Heater Hot Water The AQT watertube is an O-type construction with gas-tight, welded steel intercasing, water cooled rear wall, staggered bent tube convection section, ceramic wool front wall and optional integrated finned tube economizer. Simoneau s AQT watertube applications include hot water (high temperature / high pressure) glycol/water mixture and thermal fluid heating. Typical industries include manufacturing & processing facilities, pulp & paper, petrochemical, pharmaceuticals, hospitals, universities and many others. Simoneau s AQT Design Features: Capacities: upt o 1800 HP. Design pressures: up to 650 psig. Temperature up to 550 ºF. Two pass flue gas contact with staggered tube arrangement for maximum heat transfer. Balanced heat transfer prevents thermal shock. Operates with natural gas, #2 and alternative gases. Meets or exceeds NOx Emission Standards while providing high turndown ratio. Optional condensing economizer available. P-AQTHW-1_291110

33 AQT - Watertube Heater / Hot Water Benefits of Simoneau s AQT Watertube Heater / Hot Water Design: High efficiency provides significant fuel savings. Minimizes installation and maintenance costs. Extensive capacity range and excellent long-term reliability to meet commercial, industrial and institutional applications. Provides quick load response, low operating and reduced maintenance costs. Boiler system components (burner, controls and emissions options) designed specifically to provide ease of operation. Why Simoneau: As a Solution Builder in Energy Management, Simoneau utilizes its technical expertise (most qualified engineering team in the industry) and quality manufacturing to provide custom solutions for your specific boiler applications. Reliability, efficiency and the safety of its boiler systems are key results of the Simoneau designs. Our integration of technical expertise, quality manufacturing, on-time delivery and field support makes Simoneau your partner of choice. To learn more about Simoneau and its products, please contact: Represented by: LE GROUPE SIMONEAU INC De Coulomb Street Boucherville (Québec) J4B 8C5 P F info@groupesimoneau.com P-AQTHW-2_291110

34 AQT Type Hot water heater 1 Hot water Heaters are registred under ASME Code Section IV for operation up to 160 PSIG & 250 ºF. Ø" D " GAS OUTLET BAFFLE WATER OUTLET BURNER " C " GAS OUTLET SIMONEAU OBSERVATION PORT WATER INLET ACCESS DOOR " B " DRAINS FOR EACH PASS " A " 1 1/2 " NPT BLOW-OFF Services Services Services Boiler Model Number Capacity MMBTU / hr A Length B Width C Height D Gas Outlet Dry WEIGHTS (in Pounds) HW-100 3, / /16 12 dia. 7,200 8,250 HW-125 4, / /16 16 dia. 7,750 9,000 HW-150 5, / /16 16 dia. 8,750 10,000 HW-175 6, /16 18 dia. 9,250 10,750 HW-200 6, / /16 18 dia. 10,250 12,000 HW-250 8, /16 20 dia. 12,250 14,500 HW , / /16 20 dia. 13,250 15,500 HW , /16 20 dia. 14,250 16,750 HW , / /16 24 dia. 17,250 20,500 HW , / /16 24 dia. 18,000 21,250 HW , / /16 24 dia. 19,250 23,000 HW , / /8 30 dia. 23,500 28,250 HW , / /8 32 dia. 25,750 31,250 HW , / /8 32 dia. 28,040 29,750 HW , / /8 32 dia. 29,750 36,000 HW , / /4 36 dia. 35,000 43,250 HW , / /4 36 dia. 36,500 45,000 HW , / /4 36 dia. 37,500 46,850 Capacities up to 2000 HP available upon request. All dimensions are imperial. Flooded DS-AQTH-1_211210

35 AQT Type Hot water heater 2 Typical AQT Hot Water Heater DS-AQTH-2_ DESIGNED BY OUR ENGINEERING TEAM: 1541 De Coulomb Street Boucherville (Québec) J4B 8C5 P F info@groupesimoneau.com Solution builder in energy management

36 TYPICAL SPECIFICATIONS PACKAGED AQUATUBE HEATERS HOT WATER HEATER Project Reference: Fabricated as per ASME Section IV 1

37 1. APPLICATION REQUIREMENTS Aquatube Hot Water Heater Model: HW Rated Heater Output: MBTU/hr Design Pressure: psig Operating Temperature supply: F assumed Operating Temperature return: F assumed ASME Code Section: I Dimensions: o Length: o Width: o Height: Available Gas Pressure: psig Burner Model: Rated Input: MMBTU/hr natural gas MMBTU/hr #2 oil Power Supply: / / 2. GENERAL HEATER REQUIREMENTS Provide a high temperature hot water heater(s) shop of the packaged flexible steel water tube design. The heater (s) will be designed for pressurized firing, complete with a heavy structural steel base, trim, burner, burner controls and appurtenances. The heater(s) will be shop hydrostatic tested, inspected and stamped by a recognized government inspector in accordance with ASME Code Section I. As a complete factory assembled package, the heater(s) shall be ready for the attachment of water, fuel, drain, electrical, stack and venting connections. The hot water heater(s) specified herein shall be designed to produce ( ) MMBTU/hour continuously at F outlet temperature and F return temperature. All pressure containing parts, accessories, fixtures and fittings shall be designed and constructed for psig design pressure, in accordance with the latest edition of the applicable ASME Code Section I. The heater(s) will be furnished as a complete factory assembled unit, consisting of the pressure vessel assembly, burner, fuel trains, combustion and flame safeguard controls. 3. ACCEPTABLE EQUIPMENT The packaged hot water heater shall be an AQUATUBE Balanced Flow heater design. 2

38 4. HEATER DESIGN The heater shall be a steel flexible water tube of the two drum of O type design. The furnace and convection passes shall consist of tangent tubes on both sides of the furnace forming a symmetrical and straggered layout, assuring a balanced flow circulation pattern under all load conditions. The design will provide longitudinal gas passes separated with staggered water wall tubes to provide turbulent gas flow and maximize heat transfer. The heater rear wall shall be constructed of a full membrane water tube configuration for all generators over 80 HP to provide high efficiency, cooling of combustion gases and increased heat transfer. No refractory will be used in the target wall area, except around the access door. All heater tubes will be a minimum of 1.5 inches in diameter, inch minimum wall thickness for the boiler from 20 to 1200 HP and be easily accessible for individual replacement. To ensure positive circulation of water, the heater will be designed with baffles in headers in order to increase velocity of water, and integral orifices in downcomer tubes to insure equal repartition in each tube and prevent steaming and steam plug. A dedicated heater tube will be incorporated in the design to permit any entrained air at the top of the lower header to pass freely into the upper header. Hole drilled at top of baffles in headers will insure the same. The combustion chamber construction will consist of water tubes strength welded to headers on both sides, floor and roof. The front wall will be constructed of ceramic fibre blocks rated at 2400 F. The rear target wall will be water cooled without the use of any refractory except on the boilers from 20 to 80 HP where it will be like the front wall. The inner casing s will be fabricated of 11 gauge steel overlaid with a 2 inch thick insulation rated at 2300 F. This casing will be seal welded construction and will be designed to contain the products of combustion at the maximum operating furnace pressure. The outer casings shall consist of 14 gauge corrugated pre-painted steel panels, underlain with 2 inch fibreglass blanket insulation. There will be an adequate air space between inner and outer casings to assist in insulation. Top is made of checker plates. The furnace shall be accessible from the rear with a double man door, headers will be provided with hand holes. Observation ports will be provided for viewing the combustion conditions. The exhaust gas vent connection will be located at the front top center line of the heater and at the back for heater for 80 HP and less. Rear connection for heaters 100 HP and more is available as an option. 3

39 Lifting lugs shall be furnished on the heater top header, to facilitate rigging and lifting of the unit. 5. HEATER TRIM AND CONNECTIONS A flanged hot water supply connection will be located on the center line at the front of the upper and lower headers. A heater water drain connection will be provided at the rear of the lower header. An air vent connection will be provided on the center line of the upper header. Safety relief valve(s) in compliance with ASME code will be furnished. A heater water temperature gauge will be provided. A manual drain valve will be provided. Hot water temperature controls will be provided for operation, high limit (auto reset) and high/high limit (manual reset). Probe type main and auxiliary low water cut off control will be furnished as an integral part of the heater upper header connection. 4

40 Catalog of products AQT HEATER - GLYCOL/THERMAL FLUID >>

41 Solution builder in energy management AQT Heater Glycol/Water, Thermal Fluid The Simoneau AQT Heater is an O-type construction with gas-tight, welded steel intercasing, water cooled rear wall, staggered bent tube convection section, ceramic wool front wall. Simoneau s AQT Heater applications glycol/water mixture and thermal fluid heating. Typical industries include manufacturing & processing facilities, pulp & paper, petrochemical, pharmaceuticals, hospitals, universities and many others. Simoneau s AQT Heater Design Features: Capacities: up to 75 MMBTU/HR. Design pressures: up to 500 psig. Temperature up to 550 F. Two pass flue gas contact with staggered tube arrangement for maximum heat transfer. Balanced heat transfer prevents thermal shock. Operates with natural gas, #2 oil and alternative gases. Meets or exceeds NOx Emission Standards while providing high turndown ratio. P-AQTH-1_

42 AQT Heater Glycol/Water, Thermal Fluid Benefits of Simoneau s AQT Heater Design: High efficiency provides significant fuel savings. Minimizes installation and maintenance costs. Extensive capacity range and excellent long-term reliability to meet commercial, industrial and institutional applications. Provides quick load response, low operating and reduced maintenance costs. Heater system components (burner, controls and emissions options) designed specifically to provide ease of operation. Why Simoneau: As a Solution Builder in Energy Management, Simoneau utilizes its technical expertise (most qualified engineering team in the industry) and quality manufacturing to provide custom solutions for your specific boiler applications. Reliability, efficiency and the safety of its boiler systems are key results of the Simoneau designs. Our integration of technical expertise, quality manufacturing, on-time delivery and field support makes Simoneau your partner of choice. To learn more about Simoneau and its products, please contact: Represented by: LE GROUPE SIMONEAU INC De Coulomb Street Boucherville (Québec) J4B 8C5 P F info@groupesimoneau.com P-AQTH-2_291110

43 AQT Type Heater Glycol / Thermal Fluid 1 AQT Heaters are registred under ASME Code Section I. Ø" D " GAS OUTLET BAFFLE WATER OUTLET BURNER " C " GAS OUTLET SIMONEAU OBSERVATION PORT WATER INLET ACCESS DOOR " B " DRAINS FOR EACH PASS " A " 1 1/2 " NPT BLOW-OFF Services Services Services Boiler Model Number Capacity MMBTU / hr A Length B Width C Height D Gas Outlet Dry WEIGHTS (in Pounds) TF-100 2, / /16 12 dia. 7,200 8,250 TF-125 3, / /16 16 dia. 7,750 9,000 TF-150 4, / /16 16 dia. 8,750 10,000 TF-175 4, /16 18 dia. 9,250 10,750 TF-200 5, / /16 18 dia. 10,250 12,000 TF-250 6, /16 20 dia. 12,250 14,500 TF-300 8, / /16 20 dia. 13,250 15,500 Flooded TF-350 9, /16 20 dia. 14,250 16,750 TF , / /16 24 dia. 17,250 20,500 TF , / /16 24 dia. 18,000 21,250 TF , / /16 24 dia. 19,250 23,000 TF , / /8 30 dia. 23,500 28,250 TF , / /8 32 dia. 25,750 31,250 TF , / /8 32 dia. 28,040 29,750 TF , / /8 32 dia. 29,750 36,000 TF , / /4 36 dia. 35,000 43,250 TF , / /4 36 dia. 36,500 45,000 TF , / /4 36 dia. 37,500 46,850 Capacities up to 2000 HP available upon request. All dimensions are imperial. Sizing and dimension may vary depending on temperature and pressure design and are available upon request. DS-AQTGH-1_211210

44 AQT Type Heater Glycol / Thermal Fluid 2 Typical AQT Heater Glycol / Thermal Fluid DS-AQTGH-1_ DESIGNED BY OUR ENGINEERING TEAM: 1541 De Coulomb Street Boucherville (Québec) J4B 8C5 P F info@groupesimoneau.com Solution builder in energy management

45 TYPICAL SPECIFICATIONS PACKAGED AQUATUBE HEATERS HIGH TEMPERATURE 60% TRI-ETHYLENE GLYCOL (TEG) HEATER Project Reference: Fabricated as per ASME Section 1 1

46 1. APPLICATION REQUIREMENTS Aquatube High Temperature TEG Heater Model: AQT T Rated Heater Output: MMBTU/hr Design Pressure: psig Operating Temperature supply: F Operating Temperature return: F ASME Code Section: I 2. GENERAL HEATER REQUIREMENTS Provide a 60% Tri-Ethylene Glycol heater(s) shop assembled of the packaged flexible steel water tube design. The heater(s) will be designed for pressurized firing, complete with a heavy structural steel base, trim, burner, burner controls and appurtenances. The heater(s) will be shop hydrostatic tested, inspected and stamped by a recognized government inspector in accordance with ASME Code Section I. As a complete factory assembled package, the heater(s) shall be ready for the attachment of water, fuel, drain, electrical, stack and venting connections. The hot water heater(s) specified herein shall be designed to produce MMBTU/hour continuously at F outlet temperature and F return temperature. All pressure containing parts, accessories, fixtures and fittings shall be designed and constructed for psig design pressure, in accordance with the latest edition of the applicable ASME Code Section I. The heater(s) will be furnished as a complete factory assembled unit, consisting of the pressure vessel assembly, burner, fuel trains, combustion and flame safeguard controls. 3. ACCEPTABLE EQUIPMENT The packaged 60% Tri-Ethylene Glycol heater shall be an AQUATUBE Balanced Flow heater design. 4. HEATER DESIGN The heater shall be a steel flexible water tube of the two drum of O type design. The furnace and convection passes shall consist of tangent tubes on both sides of the furnace forming a symmetrical and straggered layout, assuring a balanced flow circulation pattern under all load conditions. The design will provide longitudinal gas passes separated with staggered water wall tubes to provide turbulent gas flow and maximize heat transfer. 2

47 The heater rear wall shall be constructed of a full membrane water tube configuration to provide high efficiency, cooling of combustion gases and increased heat transfer. No refractory will be used in the target wall area, except around the access door. All heater tubes will be a minimum of 1.5 inches in diameter, inch minimum wall thickness for the boiler from 20 to 1200 HP and be easily accessible for individual replacement. To ensure positive circulation of water, the heater will be designed with baffles in headers in order to increase velocity of water, and integral orifices in downcomer tubes to insure equal repartition in each tube and prevent steaming and steam plug. A dedicated heater tube will be incorporated in the design to permit any entrained air at the top of the lower header to pass freely into the upper header. Hole drilled at top of baffles in headers will insure the same. The combustion chamber construction will consist of water tubes strength welded to headers on both sides, floor and roof. The front wall will be constructed of ceramic fibre blocks rated at 2400 F. The rear target wall will be water cooled without the use of any refractory except on the boilers from 20 to 80 HP where it will be like the front wall. The inner casing s will be fabricated of 11 gauge steel overlaid with a 2 inch thick insulation rated at 2300 F. This casing will be seal welded construction and will be designed to contain the products of combustion at the maximum operating furnace pressure. The outer casings shall consist of 14 gauge corrugated pre-painted steel panels, underlain with 2 inch fibreglass blanket insulation. There will be an adequate air space between inner and outer casings to assist in insulation. Top is made of checker plates. The furnace shall be accessible from the rear with a double man door, headers will be provided with hand holes. Observation ports will be provided for viewing the combustion conditions. The exhaust gas vent connection will be located at the front top center line of the heater. Lifting lugs shall be furnished on the heater top header, to facilitate rigging and lifting of the unit. 5. HEATER TRIM AND CONNECTIONS (see P & ID) 3

48 Catalog of products BIOMASS FUEL / Hybrid Boiler Steam and Hot Water / D, A-Type >>

49 Solution builder in energy management LeGroupe Simoneau Biomass/Solid Fuel Burning Boilers Biomass/Solid Fuel Boilers are designed to burn a variety of fuels. Wood based products to include pellets, pucks, residuals Other biomass products to include sorghum, switch grass, miscanthus, wheat straws, corn stover, dried grain pellets, and other agri-fuels. Simoneau offers different designs to meet different requirements. Hybrid Boiler - utilizing the watertube radiant section and firetube convection section. Capacities range from 5,000 pph to 40,000 pph Open-bottom A-type - is used to achieve higher capacities of steam, 50,000 pph to 125,000 pph Special design D-type providing capacities up to 100,000 pph steam. Simoneau partners with others who design and manufacture the combustion chamber and related equipment. This provides Simoneau with the ability to provide the complete package and take single source responsibility..

50 Solution builder in energy management Hybrid Biomass Fuel Boiler The Hybrid Biomass Fuel Boiler integrates a membrane or fixed waterwall furnace with a steam generating firetube section. The Hybrid boiler maximizes heat transfer through the extensive radiant and convective heating surface combining watertube and firetube steam generation. Hybrid boilers are best utilized when a bi-product is readily available as an alternate fuel (wood, manure, biomass, bagasse, coal, etc.). Hybrid boiler installations offer economic benefits in addition to the fuel savings such as disposal fees, tax incentives, environmental implications, etc. Typical industries include manufacturing & processing facilities, pulp & paper, saw mills, universities, hospitals, greenhouses and ethanol plants. Simoneau s Hybrid Biomass Fuel Boiler Design Features: Capacities: 5,000 PPH to 60,000 PPH. Design pressures: 30 psig to 450 psig. High or low pressure steam and hot water. Large volume of water provides stable steam flow. Completely water cooled furnace membrane walls. Wet back firetube steam generating section. Small foot-print. Open bottom furnace to fit a variety of combustion systems. Auxiliary burner optional. P-HBF-1_161210

51 Hybrid - Biomass Fuel Boiler Benefits of Simoneau s Hybrid Biomass Fuel Boiler Design: Reliable source of high quality, dry, saturated steam (up to 99.9%). Extensive capacity range and excellent long-term reliability to meet commercial, industrial and institutional applications. Alternative solid fuel firing - for cost savings. Custom application engineering and site-specific design. Why Simoneau: As a Solution Builder in Energy Management, Simoneau utilizes its technical expertise (most qualified engineering team in the industry) and quality manufacturing to provide custom solutions for your specific boiler applications. Reliability, efficiency and the safety of its boiler systems are key results of the Simoneau designs. Our integration of technical expertise, quality manufacturing, on-time delivery and field support makes Simoneau your partner of choice. To learn more about Simoneau and its products, please contact: Represented by: LE GROUPE SIMONEAU INC De Coulomb Street Boucherville (Québec) J4B 8C5 P F info@groupesimoneau.com P-HBF-2_161210

52 Hybride Type Boiler 1 Our Hybrid boilers can be adapted for hot water and high or low pressure steam wood or other waste may be burned. Boiler Model Number Capacity # / hre A Length B Width C Heigth D Gas Outlet Weigths (in Pounds) H ,625 PPH / /2 69 7/8 x 14 1/8 29,000 45,000 H ,250 PPH /4 81 x 14 1/8 42,000 64,000 H ,150 PPH 211 1/ / /8 90 7/8 x 21 3/8 49, ,500 H ,895 PPH 211 1/ / /8 90 7/8 x 21 3/8 52, ,000 H ,000 PPH 264 7/ / / /8 x 37 3/8 108, ,350 Dry Flooded Design of additional capacity is on going. Simoneau will appreciate reviewing your specific requirements. DS_HBF-1_161210

53 Hybride Type Boiler 2 Typical Hybrid boiler with extensive convenction surface Extensive convection surface DS_HBF-2_ DESIGNED BY OUR ENGINEERING TEAM: 1541 De Coulomb Street Boucherville (Québec) J4B 8C5 P F info@groupesimoneau.com Solution builder in energy management

54 Solution builder in energy management A-Type Watertube Boiler The A-Type watertube design represents a symmetrical, well balanced boiler with a large furnace volume, designed with a centered steam drum and two lower mud drums. The A-Type configuration allows increased capacities (up to 250,000 PPH) and higher operating pressures (up to 1500 psig) than other watertube designs. Simoneau s A-Type, given its large design capacities, is well suited for cogeneration and solid fuel firing (with an open bottom furnace). Typical industries include manufacturing & processing facilities, pulp & paper, chemical, and petrochemical. Typical industries include manufacturing & processing facilities, pulp & paper,petrochemical, pharmaceuticals, hospitals, universities and ethanol plants. Simoneau s A-Type Design Features: Capacities: Up to 250,000 PPH. Design pressures: 250 psig to 1500 psig. Radiant and convective type superheaters with temperatures up to 1000 ºF. Gas tight membrane waterwall design. Superior steam quality (1 ppm) using proprietary separation technology. Operates with natural gas, #2 thru #6 oil and alternative fuels. Available with open bottom furnace for solid fuel firing. Meets or exceeds NOx Emission Standards while providing high turndown ratio. Indoor or outdoor designs. Symmetrical design with natural circulation. P-AT-1_291110

55 A-Type - Watertube Boiler Benefits of Simoneau s A-Type Watertube Boiler Design: Reliable source of high quality, dry, saturated steam (up to 99.9%). Extensive capacity range and excellent long-term reliability to meet industrial and utility applications. Improved shipping capabilities by road or train with its symmetrical balanced weight distribution. Boiler system components (burner, controls, economizer, soot blower, emissions options) designed specifically to provide ease of operation. Why Simoneau: As a Solution Builder in Energy Management, Simoneau utilizes its technical expertise (most qualified engineering team in the industry) and quality manufacturing to provide custom solutions for your specific boiler applications. Reliability, efficiency and the safety of its boiler systems are key results of the Simoneau designs. Our integration of technical expertise, quality manufacturing, on-time delivery and field support makes Simoneau your partner of choice. To learn more about Simoneau and its products, please contact: Represented by: LE GROUPE SIMONEAU INC De Coulomb Street Boucherville (Québec) J4B 8C5 P F info@groupesimoneau.com P-AT-2_291110

56 Solution builder in energy management

57 Solution builder in energy management

58 Catalog of products WASTE HEAT RECOVERY BOILER >>

59 Solution builder in energy management LeGroupe Simoneau Waste Heat Recovery Boilers/Generators Steam and hot water generation is an excellent way to recover waste heat energy from a variety of sources. LeGroupe Simoneau provides design, engineering and fabrication of waste heat recovery boilers and generators. Enormous quantities of heat energy, inherent in exhaust gases, can be recovered to reduce energy consumption and improve efficiencies. Waste heat (exhaust) is available from a variety of sources to include toxic oxidizers (incinerators), burning municipal waste, gas turbine off gas, burning biomass products, exhaust gases from various industrial processes, etc. The applications of waste heat boilers and generators are typically unique and application specific. This equipment commonly requires design/engineering input to effectively and efficiently manage waste heat energy. Capacities range from 5,000 pph to 125,000 pph utilizing high pressures and high temperatures. Auxiliary Equipment Simoneau understands all aspects of the waste heat recovery process. We can design and include a wide range of auxiliary equipment to provide a complete engineered solution PLC based control systems Deaerators Feedwater pumps Bypass Dampers Blowdown tanks LeGroupe Simoneau s ThermoDesign Engineering group can provide solutions to your specific applications. We can take your specific operating data and design equipment to fit your unique applications. Operating data that will allow our engineering team to put together a proposal include: Source of heat Volume of waste heat Chemical composition of waste heat source Temperature expected Expectation of the waste heat recovery process steam, hot water, volume Envelope available

60 Solution builder in energy management

61 Solution builder in energy management

62

63

64

65 Catalog of products PACKAGED A-TYPE >>

66 Solution builder in energy management A-Type Watertube Boiler The A-Type watertube design represents a symmetrical, well balanced boiler with a large furnace volume, designed with a centered steam drum and two lower mud drums. The A-Type configuration allows increased capacities (up to 250,000 PPH) and higher operating pressures (up to 1500 psig) than other watertube designs. Simoneau s A-Type, given its large design capacities, is well suited for cogeneration and solid fuel firing (with an open bottom furnace). Typical industries include manufacturing & processing facilities, pulp & paper, chemical, and petrochemical. Typical industries include manufacturing & processing facilities, pulp & paper,petrochemical, pharmaceuticals, hospitals, universities and ethanol plants. Simoneau s A-Type Design Features: Capacities: Up to 250,000 PPH. Design pressures: 250 psig to 1500 psig. Radiant and convective type superheaters with temperatures up to 1000 ºF. Gas tight membrane waterwall design. Superior steam quality (1 ppm) using proprietary separation technology. Operates with natural gas, #2 thru #6 oil and alternative fuels. Available with open bottom furnace for solid fuel firing. Meets or exceeds NOx Emission Standards while providing high turndown ratio. Indoor or outdoor designs. Symmetrical design with natural circulation. P-AT-1_291110

67 A-Type - Watertube Boiler Benefits of Simoneau s A-Type Watertube Boiler Design: Reliable source of high quality, dry, saturated steam (up to 99.9%). Extensive capacity range and excellent long-term reliability to meet industrial and utility applications. Improved shipping capabilities by road or train with its symmetrical balanced weight distribution. Boiler system components (burner, controls, economizer, soot blower, emissions options) designed specifically to provide ease of operation. Why Simoneau: As a Solution Builder in Energy Management, Simoneau utilizes its technical expertise (most qualified engineering team in the industry) and quality manufacturing to provide custom solutions for your specific boiler applications. Reliability, efficiency and the safety of its boiler systems are key results of the Simoneau designs. Our integration of technical expertise, quality manufacturing, on-time delivery and field support makes Simoneau your partner of choice. To learn more about Simoneau and its products, please contact: Represented by: LE GROUPE SIMONEAU INC De Coulomb Street Boucherville (Québec) J4B 8C5 P F info@groupesimoneau.com P-AT-2_291110

68 A Type Steam Watertube Boiler 1 Side elevation Front view Boiler Model Number Capacity # / hre A Length B Width C Heigth D Gas Outlet E Gas Outlet Width F Length Dry Weigths (in Pounds) A , ,000 80,000 A , ,000 90,000 A , , ,000 A , , ,000 A , , ,000 A , , ,000 A , , ,000 A , , ,000 A , , ,000 A , , ,000 A , , ,000 A , , ,000 A , , ,000 A , , ,000 A , , ,000 All dimensions are imperial Flooded DS-A T-1_071210

69 A Type Steam Watertube Boiler 2 DS-A T-2_ DESIGNED BY OUR ENGINEERING TEAM: 1541 De Coulomb Street Boucherville (Québec) J4B 8C5 P F info@groupesimoneau.com Solution builder in energy management

70 Solution builder in energy management

71 TYPICAL SPECIFICATIONS Project Reference: WATERTUBE BOILER MODEL A-TYPE Fabricated as per ASME Section 1 1

72 1. DESIGN SUMMARY Watertube Steam Generator model no.: A- Maximum continuous rating: PPH Fuel fired: Waste liquids Design pressure: psig Operating pressure: psig Gas exit temperature from boiler: F Operating temperature: Saturated steam Feedwater temperature: F Elevation: Seal Level Location: Outdoors Steam separating equipment: Baffles and dry pan Steam purity guarantee: PPM Heating surfaces: o Furnace (flat projected): sq. ft. o Convection: sq. ft. o Furnace volume: cu. ft. o Mud drum steam coil consumption: psig sat. Pressure parts: Diam. Thick Material o Steam drum shells: I.D. in. SA o Steam drum heads: I.D. in. SA o Mud drum shell: I.D. in. SA o Mud drum head: I.D. in. SA o Furnace floor, sidewall, roof tubes: O.D SA-178A-ERW o Boiler rear wall tubes: O.D SA-178A-ERW o Convection sidewall tubes: O.D SA-178A-ERW o Convection free standing tubes: O.D SA-178A-ERW Overall dimensions excluding burner and windbox: o Base length: ft. in. o Width: ft. in. o Height: ft. in. Approximate dry weight without burner: lbs o NWL: lbs o Flooded: lbs The above specified design data may be subject to modifications after final design check. 2. DESIGN AND CONSTRUCTION The Thermodesign A-Type Watertube Steam Generator is a design with integral furnace and two (2) convection boiler banks. The flue gases will enter the convection zone at the end of 2

73 the furnace and circulate through the boiler bank toward the front of the unit and exit at the top of the boiler. The steam generator is designed for pressurized operation. The gas tight construction is achieved by sealed skin casing, sidewall, roof, boiler sidewall and inner seal welded steel casings enclosing the refractory. The unit is tested at 10 W.C. with all seams checked with soapy water. The steam generator pressure parts are fabricated and hydrostatically tested in accordance with the latest edition of the ASME Code, Section 1, Power Boilers. Steam and Mud Drums All seams are fusion welded, X-rated and stress relieved. The steam and mud drums are provided at each end with a 12 x 16 manhole opening and cover. Steam drum manhole covers are supported on hinges. All drum connections, 2 and above, are flanged. Connections were provided for: o Steam outlet o Safety valves o Feedwater inlet o Continuous blowdown o Pressure gauge o Feedwater regulator o Water column o Chemical feed o Sootblower o Intermittent blowdown o Low water cut-off o Vent Properly supported internal piping is provided in the steam drum for feedwater distribution, chemical feed and continuous blowdown. The steam drum is supplied with suitable designed internal baffles chevrons and/or steam separators as required to maintain the guaranteed steam purity. Tubes All steam generator tubes are entering the drum radially. Tube ends are free of scale on the surface and are expanded into the drums. Tube arrangement is as follows: o Boiler convection bank: Free standing bare tubes o Boiler bank rear wall: Free standing bare tubes o Boiler bank sidewalls: Finned tubes o Furnace rearwall: Free standing bare tubes o Furnace sidewall and floor: Finned tubes 3

74 Access door A gas tight refractory lined furnace access door is provided at the rear of the steam generator. Sootblower bearings and wallbox As standard, sootblower(s) bearings and wallbox(es) are supplied. 3. REFRACTORY INSULATION - CASING The packaged steam generator is supplied with the following refractory, insulation and casings. o Boiler sidewalls: 3 blanket insulation 16 ga. outer casing o Furnace front wall: 4 ½ fireback 2 ½ insulbrick 4 insulblock 3/8 front plate o Furnace floor: 3 blanket insulation o Boiler front wall: 3 blanket insulation 11 ga. outer casing o Boiler rear wall: 2 firebrick 8 castable refractory 3/8 rear plate 3 blanket insulation 11 ga. outer casing o Steam drum: 3 blanket insulation 11 ga. outer casing The outer casing surface temperature will not exceed 60 F above ambient temperature with a surface air velocity of 100 fpm when the boiler is operating at maximum continuous capacity. 4. STEAM GENERATOR AND STRUCTURES Doors Observations Ports Instrument Sleeves Two (2) air-cooled observation ports are provided in an approximate centered location on the furnace back wall. One (1) access door is provided at the rear end of the boiler casing allowing entry under the furnace of the boiler. Miscellaneous doors are provided in gas and air ductwork, as required. All doors are fitted with insulation and/or refractory as required and made tight by means of gaskets to minimize possible gas leakage. Instrument sleeves and openings are provided as required for combustion and burner management controls. 4

75 Structural Base One (1) rigid structural steel frame is designed to distribute the steam generator load on the base. 5. STEAM GENERATOR VALVES AND MOUNTINGS For details see the trim list and the P&I diagram. Performance Conditions Performance data for the steam generator as submitted in this document and made part of this document are in accordance with the recommendations of the American Boiler Manufacturer Association (ABMA). It is recognized that the performance of the equipment covered in this document cannot be exactly predicted for every possible operating condition. In consequence, any predicted performance data submitted are intended to show probable operating results which may be closely approximated but which cannot be guaranteed except as expressly stated in the guarantee clause of this document. Boiler water concentrations will not exceed those shown in the table below with ppm defined as parts per million per weight: Notes: Drum pressure PSIG Total dissolved Solids (1) PPM (max.) Total Alkalinity PPM (2) (4) Suspended Solids PPM (max.) Total dissolved Solids in steam PPM (2.3) (max.) Actual values within the range reflect the TDS in the feedwater. Higher values are for high solids, lower values are for low solids in the feedwater. Actual values within the range are directly proportional to the actual value of TDS of boiler water. Higher values are for the high solids, lower values are for low solids in the boiler water. These values are exclusive of silica. Expressed as equivalent calcium carbonate in PPM. The equipment is to be clean inside and out. PPM is defined as part per million by weight. 6. PERFORMANCE GUARANTEES Subject to the performance conditions stated in this document. Thermodesign makes the following guarantees: 5

76 Performance at full capacity: At a capacity of,000 PPH of steam at psig operating pressure and F operating temperature: o The combined efficiency of the unit will not be less than % with firing. o Steam purity will not be less than ppm. The performance guarantees are based on the following conditions: o Temperature of ambient air: 80 F o Relative humidity of ambient air: 60% o Elevation: Sea level o Feedwater temperature entering the economizer: F o Fuel excess air: % o Blow down rate: % estimated o Fuel: 6

77 Catalog of products PACKAGED D-TYPE >>

78 Solution builder in energy management D-Type Watertube Boiler The D-Type watertube design represents one of the most popular configurations for watertube boilers. Simoneau s D-Type watertube boiler is of a quality design with proven reliability. The D-Type design is commonly used for saturated steam applications with capacities below 250,000 PPH. Typical industries include manufacturing & processing facilities, pulp & paper, petrochemical, pharmaceuticals, hospitals, universities and ethanol plants. Simoneau s D-Type Design Features: Capacities: 10,000 PPH to 200,000 PPH. Design pressures: 250 psig to 750 psig. Convective type superheaters with temperatures up to 750 ºF. Waterwall design built with gas tight membrane or tangent tubes. Superior steam quality (1 ppm) using proprietary separation technology with a large steam drum. Operates with natural gas, #2 thru #6 oil and alternative fuels. Meets or exceeds NOx Emission Standards while providing high turndown ratio. Indoor or outdoor designs with right and left hand models. P-DT-1_291110

79 D-Type - Watertube Boiler Benefits of Simoneau s D-Type Watertube Boiler Design: Reliable source of high quality, dry, saturated steam (up to 99.9%). Extensive capacity range and excellent long-term reliability to meet commercial, industrial and institutional applications. Provides quick load response, low operating and reduced maintenance costs. Boiler system components (burner, controls, economizer, soot blower, emissions options) designed specifically to provide ease of operation. Why Simoneau: As a Solution Builder in Energy Management, Simoneau utilizes its technical expertise (most qualified engineering team in the industry) and quality manufacturing to provide custom solutions for your specific boiler applications. Reliability, efficiency and the safety of its boiler systems are key results of the Simoneau designs. Our integration of technical expertise, quality manufacturing, on-time delivery and field support makes Simoneau your partner of choice. To learn more about Simoneau and its products, please contact: Represented by: LE GROUPE SIMONEAU INC De Coulomb Street Boucherville (Québec) J4B 8C5 P F info@groupesimoneau.com P-DT-2_291110

80 D Type Steam Watertube Boiler 1 Side elevation Front view Boiler Model Number Capacity # / hre A Length B Width C Heigth D Gas Outlet E Width Gas Outlet F Length Dry Weigths (in Pounds) FX-10 10, ,000 50,000 FX , ,000 55,000 FX-15 15, ,000 58,000 FX , ,000 63,000 FX-20 20, ,000 66,000 FX-25 25, ,000 75,000 FX-30 30, ,000 78,000 FX-35 35, ,000 87,000 FX-40 40, ,000 95,000 FX-45 45, , ,000 FX-50 50, , ,000 FX-55 55, , ,000 FX-60 60, , ,000 FX-65 65, , ,500 FX-70 70, , ,000 FX-75 75, , ,000 FX-80 80, , ,000 FX-90 90, , ,000 FX , , ,000 FX , , ,000 FX , , ,000 FX , , ,000 FX , , ,000 Flooded DS-DT-1_071210

81 D Type Steam Watertube Boiler 2 DS-DT-2_ DESIGNED BY OUR ENGINEERING TEAM: 1541 De Coulomb Street Boucherville (Québec) J4B 8C5 P F info@groupesimoneau.com Solution builder in energy management

82 TYPICAL SPECIFICATIONS Project Reference: WATERTUBE BOILER MODEL D-TYPE Fabricated as per ASME Section 1 1

83 1. DESIGN SUMMARY Watertube Steam Generator model no.: FX- Maximum continuous rating: lbs/hr Fuel fired: Design pressure: psig Operating pressure: psig Steam outlet temperature: F Feedwater temperature: F Elevation: ft above sea level Location: Indoor/Outdoor Steam separating equipment: Baffles and dry pan Steam purity guarantee: % Pressure parts: Diam. Thick Material o Steam drum shells: I.D. in. SA o Steam drum heads: I.D. in. SA o Mud drum shell: I.D. in. SA o Mud drum head: I.D. in. SA o Furnace floor, sidewall, roof tubes: O.D SA-178A-ERW o Boiler rear wall tubes: O.D SA-178A-ERW o Convection sidewall tubes: O.D SA-178A-ERW o Convection free standing tubes: O.D SA-178A-ERW Overall dimensions excluding burner and windbox: o Base length: ft. in. o Width: ft. in. o Height: ft. in. 2. DESIGN AND CONSTRUCTION The Thermodesign D-Type Membrane Wall Watertube Steam Generator is a design with integral furnace and one (1) convection boiler bank. The flue gases will enter the convection zone at the end of the furnace and circulate through the boiler bank toward the front of the unit and exit at the side of the boiler. The steam generator is designed for pressurized operation. The gas tight construction is achieved by providing continuous seal welded finned tubes for the furnace floor, sidewall, roof, boiler sidewall and inner seal welded steel casings enclosing the refractory. The unit is air tested at 10 W.C. with all seams checked with soapy water. The steam generator pressure parts are fabricated and hydrostatically tested in accordance with the latest edition of the ASME Code, Section 1, Power Boilers. Steam and Mud Drums All seams are fusion welded, X-rayed. The drums assemblies are stress relieved as required by the ASME Code. The steam and mud drum are provided at each end with a 12 x 16 manhole opening and cover. Steam drum manhole covers are supported on hinges. 2

84 Tubes All steam generator tubes are entering the drum radially. Tube ends are free of scale on the surface and are expanded into the drums. Tube arrangement is as follows: o Boiler convection bank: Free standing bare tubes o Boiler bank rear wall: Free standing bare tubes o Boiler bank sidewalls: Finned tubes o Furnace rear wall: Free standing bare tubes o Furnace sidewall and floor: Finned tubes Access door A gas tight refractory lined furnace access door is provided at the rear of the steam generator. Sootblower bearings and wallbox Sootblower(s) bearings and wallbox(es) are supplied. 3. REFRACTORY INSULATION - CASING The packaged steam generator is supplied with the following refractory, insulation and casings. o Boiler sidewalls: 3 blanket insulation 16 ga. outer casing o Furnace front wall: 4 ½ fireback 2 ½ insulbrick 4 insulblock 3/8 front plate 3 blanket 1/8 outer casing o Boiler rear wall: 2 tile 8 insulblock 3/8 rear plate 3 blanket 1/8 outer casing 11 ga. outer casing o Steam drum: 3 blanket 1/8 outer casing The outer casing surface temperature will not exceed 60 F above ambient temperature with a surface air velocity of 100 fpm when the boiler is operating at maximum continuous capacity. 3

85 4. STEAM GENERATOR AND STRUCTURES Doors Observations Ports Instrument Sleeves One (1) air-cooled observation port is provided in an approximate centered location on the rear wall. One (1) access door is provided at the rear end of the boiler casing allowing entry in boiler. Doors are provided in gas and air ductwork, as required. All doors are fitted with insulation and/or refractory as required and are made tight by means of gaskets to minimize possible gas leakage. Instrument sleeves and openings are provided as required for combustion and burner management controls. 5. STEAM GENERATOR VALVES AND MOUNTINGS For details see the trim list. Performance Conditions Performance data for the steam generator as submitted in this document and made part of this document are in accordance with the recommendations of the American Boiler Manufacturer Association (ABMA). It is recognized that the performance of the equipment covered in this document cannot be exactly predicted for every possible operating condition. In consequence, any predicted performance data submitted are intended to show probable operating results which may be closely approximated but which cannot be guaranteed except as expressly stated in the guarantee clause of this document. Boiler water concentrations will not exceed those shown in the table below with PPM defined as parts per million per weight: Drum pressure PSIG Notes: Total dissolved Solids (1) PPM (max.) Total Alkalinity PPM (2) (4) Suspended Solids PPM (max.) Total dissolved Solids in steam PPM (2.3) (max.) Actual values within the range reflect the TDS in the feedwater. Higher values are for high solids, lower values are for low solids in the feedwater. Actual values within the range are directly proportional to the actual value of TDS of boiler water. Higher values are for the high solids, lower values are for low solids in the boiler water. These values are exclusive of silica. Expressed as equivalent calcium carbonate in PPM. 4

86 The equipment is to be clean inside and out. PPM is defined as part per million by weight. Subject to the performance conditions specified above, Thermodesign provides the guarantees as noted elsewhere in this document. 6. PERFORMANCE GUARANTEES Subject to the performance conditions stated in this document, Thermodesign guarantees the following: Performance at full capacity: At a capacity of,000 lbs/hr of saturated steam at psig operating pressure: o The combined efficiency of the unit will not be less than % with Oil #2 and % with Natural gas. o Steam quality will not be less than %. The performance guarantees are based on the following conditions: o Temperature of ambient air: 80 F ( F max.) o Relative humidity of ambient air: to be advised o Elevation: to be advised o Feedwater temperature entering the economizer: F o Fuel excess air: according to fired fuel o Blow down rate: % estimated o Fuel: to be advised 5

87 Catalog of products PACKAGED O-TYPE >> 11 12

88 O Type Steam Watertube Boiler 1 Side elevation Front view Boiler Model Number Capacity # / hre A Length B Width C Heigth D Base Width E Gas Outlet Width F Length Dry Weigths (in Pounds) O , ,000 85,000 O , ,000 90,000 O , ,000 95,000 O , , ,000 O , , ,000 O , , ,000 O , , ,000 O , , ,000 O , , ,000 O , , ,000 O , , ,000 O , , ,000 O , , ,000 O , , ,000 All dimensions are imperial Flooded DS-OT-1_071210

89 O Type Steam Watertube Boiler 2 DS-OT-2_ DESIGNED BY OUR ENGINEERING TEAM: 1541 De Coulomb Street Boucherville (Québec) J4B 8C5 P F info@groupesimoneau.com Solution builder in energy management

90 TYPICAL SPECIFICATIONS Project Reference: WATERTUBE BOILER MODEL O-TYPE Fabricated as per ASME Section 1 1

91 1. DESIGN SUMMARY Watertube Steam Generator model no.: O4- Maximum continuous rating: lbs/hr Fuel fired: Natural gas Design pressure: psig Operating pressure: psig Steam outlet temperature: Saturated Feedwater temperature: F Elevation: feet above sea level Location: Indoor/Outdoor Steam separating equipment: Baffles and dry pan Steam quality guarantee: % Pressure parts: Diam. Thick Material o Steam drum shells: I.D. in. SA o Steam drum heads: I.D. in. SA o Mud drum shell: I.D. in. SA o Mud drum head: I.D. in. SA o Furnace floor, sidewall, roof tubes: O.D SA-178A-ERW o Boiler rear wall tubes: O.D SA-178A-ERW o Convection sidewall tubes: O.D SA-178A-ERW o Convection free standing tubes: O.D SA-178A-ERW Overall dimensions excluding burner and windbox: o O.A. Base length: ft. in. o O.A. Width: ft. in. o O.A. Height: ft. in. o Approximate dry weight: xxx lbs o Approximate flooded weight: xxx lbs 2. DESIGN AND CONSTRUCTION The Thermodesign O-Type Membrane Wall Watertube Steam Generator is a design with integral furnace and two (2) convection boiler banks. The flue gases will enter the convection zone at the end of the furnace and circulate through the boiler bank toward the front of the unit and exit at the top of the boiler. The steam generator is designed for pressurized operation. The gas tight construction is achieved by providing continuous seal welded finned tubes for the furnace floor, sidewalls, roof, boiler sidewalls and inner seal welded steel casings enclosing the refractory. The unit is air tested for leaks at 10 W.C. with all seams checked with soapy water. The steam generator pressure parts are fabricated and hydrostatically tested in accordance with the latest edition of the ASME Code, Section 1, Power Boilers. 2

92 Steam and Mud Drums All seams are fusion welded, X-rayed. The drums assemblies are stress relieved as required by the ASME Code. The steam and mud drum are provided at each end with a 12 x 16 manhole opening and cover. Steam drum manhole covers are supported on hinges. Tubes All steam generator tubes are entering the drum radially. Tube ends are free of scale on the surface and are expanded into the drums. Tube arrangement is as follows: o Boiler convection bank: Free standing bare tubes o Boiler bank rear wall: Free standing bare tubes o Boiler bank sidewalls: Finned tubes o Furnace rearwall: Free standing bare tubes o Furnace sidewall, roof and floor: Finned tubes Access door A gas tight refractory lined furnace access door is provided at the rear of the steam generator. Sootblower bearings and wallbox Sootblower(s) bearings and wallbox(es) are supplied. 3. REFRACTORY INSULATION - CASING The packaged steam generator is supplied with the following refractory, insulation and casings. o Boiler sidewalls: 3 blanket insulation 16 ga. outer casing o Furnace front wall: 4 ½ fireback 2 ½ insulbrick 6 insulblock 3/8 front plate 3 blanket insulation 1/8 outer casing o Boiler rear wall: 2 tile 9 insulblock 3/8 rear plate 3 blanket 1/8 outer casing o Steam drum: 3 blanket 1/8 outer casing 3

93 The outer casing surface temperature will not exceed 60 F above ambient temperature with a surface air velocity of 100 fmp when the boiler is operating at maximum continuous capacity. 4. STEAM GENERATOR AND STRUCTURES Doors Observations Ports Instrument Sleeves One (1) air-cooled observation ports is provided in an approximate centered location on the rear wall. One (1) access door is provided at the rear end of the boiler casing allowing entry into the furnace. Doors are provided in gas and air duct work, as required. All doors are fitted with insulation and/or refractory as required and made tight by means of gaskets to minimize possible gas leakage. Instrument sleeves and openings are provided as required for combustion and burner management controls. 5. STEAM GENERATOR VALVES AND MOUNTINGS For details see the equipment trim list. Performance Conditions Performance data for the steam generator as submitted in this document and made part of this document are in accordance with the recommendations of the American Boiler Manufacturer Association (ABMA). It is recognized that the performance of the equipment covered in this document cannot be exactly predicted for every possible operating condition. In consequence, any predicted performance data submitted are intended to show probable operating results which may be closely approximated but which cannot be guaranteed except as expressly stated in the guarantee clause of this document. Boiler water concentrations will not exceed those shown in the table below with ppm defined as parts per million per weight: Drum pressure PSIG Total dissolved Solids (1) PPM (max.) Total Alkalinity PPM (2) (4) Suspended Solids PPM (max.) Total dissolved Solids in steam PPM (2.3) (max.)

94 Notes: Actual values within the range reflect the TDS in the feedwater. Higher values are for high solids, lower values are for low solids in the feedwater. Actual values within the range are directly proportional to the actual value of TDS of boiler water. Higher values are for the high solids, lower values are for low solids in the boiler water. These values are exclusive of silica. Expressed as equivalent calcium carbonate in PPM. The equipment is to be clean inside and out. PPM is defined as part per million by weight. 6. PERFORMANCE GUARANTEES Subject to the performance conditions stated in this document. Thermodesign makes the following guarantees: Performance at full capacity: At a capacity of,000 PPH of steam at psig operating pressure and F operating temperature: o The combined efficiency of the unit will not be less than % with firing. o Steam purity will not be less than ppm. The performance guarantees are based on the following conditions: o Temperature of ambient air: 80 F o Relative humidity of ambient air: 60% o Elevation: Sea level o Feedwater temperature entering the economizer: F o Fuel excess air: % o Blow down rate: % estimated o Fuel: 5

95 Catalog of products DEAERATOR / CONDENSATE / FEED WATER SYSTEM >> 12

96 Solution builder in energy management Deaerator The Simoneau deaerator design assures high purity boiler feedwater by removing the oxygen and other dissolved gases to.005cc per liter or less. The pressurized steam atmosphere works in conjunction with the spray scrubber to insure proper deaeration. A typical deaerator includes the tank mounted on a stand with all operating controls, feedwater pumps and interconnecting valves and piping. Simoneau s Deaerator Design Features: Capacities: 10,000 PPH to 600,000 PPH. Spray type deaerators with horizontal, vertical and dual compartment (DA and Surge Tank) designs. Skid or saddle mounted, completely piped and wired with instrumentationand pumps. Low profile design. Stainless steel deaeration assembly. Two-stage deaeration in common vessel. Removable spray assembly. Built of corrosion-resistant alloys to ASME Code (Section VIII). P-D-1_291110

97 Deaerator Benefits of Simoneau s Deaerator Design: Significantly extends the life time of the boiler. Custom configuration, controls and feed water pump options. Packaged systems for cost effective installation. Cost saving through miminized chemical treatment and extended boiler life. Why Simoneau: As a Solution Builder in Energy Management, Simoneau utilizes its technical expertise (most qualified engineering team in the industry) and quality manufacturing to provide custom solutions for your specific boiler applications. Reliability, efficiency and the safety of its boiler systems are key results of the Simoneau designs. Our integration of technical expertise, quality manufacturing, on-time delivery and field support makes Simoneau your partner of choice. To learn more about Simoneau and its products, please contact: Represented by: LE GROUPE SIMONEAU INC De Coulomb Street Boucherville (Québec) J4B 8C5 P F info@groupesimoneau.com P-D-2_291110

98 Deaerator up to PPH / Deaerator 1 Up to PPH Percentage of condensate: 50% Condensate temperature: 160 ºF Make up water temperature: 40 ºF Storage capacity: 10 minutes This information is subject to changes without notice DEAERATOR CAPACITY (PPH) MODEL DG-5 DG-10 DG-15 DG-20 DG-25 STEAM INLET A STORAGE TANK DIA. B STORAGE TANK LENGTH C DS_D25-1_030211

99 Deaerator up to PPH / Deaerator 2 Typical Deaerator PPH Spray type DS_D25-2_ DESIGNED BY OUR ENGINEERING TEAM: 1541 De Coulomb Street Boucherville (Québec) J4B 8C5 P F info@groupesimoneau.com Solution builder in energy management

100 Deaerator from to PPH / Deaerator 1 From to PPH Percentage of condensate: 50% Condensate temperature: 160 ºF Make up water temperature: 40 ºF Storage capacity: 10 minutes This information is subject to changes without notice DEAERATOR CAPACITY (PPH) MODEL: DG-30 DG-50 DG-60 DG-70 DG-80 STEAM INLETA A 4 x 8 6 x 12 6 x 12 7 x 14 7 x 14 STORAGE TANK DIA. B TOWER OUTSIDE DIA. C STORAGE TANK LENGTH D TOWER HEIGTH E DEAERATOR MODEL: / DG (PPH) MODEL: DG-90 DG-100 DG-125 DG-150 DG-175 STEAM INLET A 8 x 16 8 x 16 9 x x x 22 STORAGE TANK DIA. B TOWER OUTSIDE DIA. C STORAGE TANK LENGTH D TOWER HEIGTH E DS-D30-1_030211

101 Deaerator from to PPH / Deaerator 2 Typical Deaerator DS-D30-2_ DESIGNED BY OUR ENGINEERING TEAM: 1541 De Coulomb Street Boucherville (Québec) J4B 8C5 P F info@groupesimoneau.com Solution builder in energy management

102 Deaerator from to PPH / Deaerator 1 From to PPH Percentage of condensate: 50% Condensate temperature: 180 ºF Make up water temperature: 50 ºF Storage capacity: 10 minutes This information is subject to changes without notice DEAERATOR CAPACITY (PPH) MODEL: DG-200 DG-250 DG-300 DG-350 STEAM INLETA A STORAGE TANK DIA. B TOWER OUTSIDE DIA. C STORAGE TANK LENGTH D TOWER HEIGTH E Greater designs available upon request DS-D200-1_030211

103 Deaerator from to PPH / Deaerator 2 DS-D200-2_ DESIGNED BY OUR ENGINEERING TEAM: 1541 De Coulomb Street Boucherville (Québec) J4B 8C5 P F info@groupesimoneau.com Solution builder in energy management

104 TYPICAL SPECIFICATIONS DEAERATOR Project Reference: Fabricated as per ASME Section VIII, div. 1 1

105 1. GENERAL Supply and installation of a THERMODESIGN deaerator. The deaerator will be supplied with all components and controls as per the following technical data: Specifications: Model no. : DG- Capacity: lb/hr Dimensions : Length = Width = Height = ASME code section : VIII, div. 1 Design pressure : psig Operating pressure: psig Make up water percentage: % Condensate temperature: F Storage capacity: 10 minutes Steam pressure available: psig The deaerator will be fabricated in accordance with ASME and CSA B-51, and registered with the Régie du bâtiment du Québec. Each unit will be shop assembled and supplied with all required accessories. 2. DESIGN OF DEAERATORS Thermodesign deaerators are spray type, two stages. Deaerators consist of a spray type heater allowing water to be raised up to 2 or 3 degrees from the saturation temperature. This heater will be mounted on a horizontal storage tank where heated water meets the conterflow steam flow. Deaerator will be fabricated with carbon steel plates and stainless steel spray valve(s). Others parts in contact with deaerated water will receive a coat of Apexior #1. Deaerator is built in order to guarantee: o That water will be heated to a temperature close to the saturation. o That dissolved oxygen will be reduced to ml/l at the most as accepted by the Winkler test. o That carbon dioxyde will be reduced to 0.0 ppm as approved by APHA standards. o That the deaerator will operate silently at all charges. o That condensate returns will take advantage over make up water. 2

106 3. STANDARD ACCESSORIES SUPPLIED WITH THE DEAERATOR Control panel: o Nema-1 control panel enclosure o Pump motor starters with 3 phases overload and circuit breaker protection o H-O-A pump selector switches o Pump running lights o Low and high water alarms with lights o Alarm bell with silencing switch o Relay and terminal block to enable chemical feed system o Numbered terminal block o Lamicoid identification nameplate Accessories: o Manway 12 x 16 o Pneumatic or electric pressure controller o Pneumatic or electric pressure control valve o Pneumatic or electric condensate modulating make up valve o Y strainer for make up and steam inlet o 3 valves by pass for the steam and condensate make up valve assemblies o Safety relief valve for the steam pressure reducing valve o Steam safety vale set at 15 psig o Steam pressure reducing valve o Water level indicator: Redline type Automatic offset-type gage valve Drain cock on lower gage valve Gage glass protection rod o Thermometer o Pressure gage o Vacuum breaker o Water sample and chemical feed probe type 304 SS o Stainless steel ball check o Gate valve vent o Low level water alarm float type o High level alarm switch and over flow control switch probe type 4. OPTIONAL Painted structural steel base of feet high, to meet the NPSHR of the pumps. 5. OPTIONAL motor pumps featuring HP, V PH Hz. The pump will have a flow rate of USGPM and a net head pressure of psig. The pump and the motor are coupled with a flexible joint and firmly attached on the steel base. 3

107 Following accessories are supplied : o An orifice plate or a relief valve installed at the pump outlet. o A strainer installed at the inlet of the pump. o A stop and a check valve installed at the outlet of the pump (for multi pumps). 4

108 Catalog of products CUSTOM DESIGNED VESSELS & SUPERHEATERS >>

109 Solution builder in energy management Pressure Vessels Pressure vessel are build according to ASME Standard section VIII division I. Simoneau builds and concives to client specification. Reservoir from 16 inches to 16 feet in diameter ¼ to 2.5 inches wall thickness Necessary piping could be included Blow down tank build per ASME section VIII division I and local regulation Drain tank Heat recuperation Superheater Condensate tank Complete line of skid or saddle mounted reservoirs, feed water tank and also feed water system Piping and valving Steam injector Control panel Le groupe Simoneau s Thermodesign engineering group can provide solutions to your specific applications.we can take your specifics operating data and design equipment to fit your unique applications.operating data that will allow our engineering team to put together a proposal included: Design pressure Operating pressure Design temperature Operating temperature Material requirement Corrosion allowance.

110 Solution builder in energy management

111 Solution builder in energy management

112 Solution builder in energy management

113 Solution builder in energy management

114 Solution builder in energy management

115 Solution builder in energy management

116 Energy performance Energy performance custom fabricated custom fabricated 1541, de Coulomb Street Boucherville (Québec) J4B 8C5 24/7 SERVICE P F

Originators of the Flexible Water Tube design

Originators of the Flexible Water Tube design BRYAN FLEXIBLE WATER TUBE RW SERIES STEAM AND WATER BOILER 8,500,000 TO 21,000,000 BTUH FORCED DRAFT GAS, OIL OR DUAL FUEL FIRED Water Boiler RW2100-W-FDGO Steam Boiler RW1050-S-150-FDG Originators of

More information

ENERGY RECOVERY SOLUTIONS. Recover wasted energy to increase efficiency and save money immediately.

ENERGY RECOVERY SOLUTIONS. Recover wasted energy to increase efficiency and save money immediately. ENERGY RECOVERY SOLUTIONS Recover wasted energy to increase efficiency and save money immediately. Cleaver-Brooks Engineered Boiler Systems Manufacturers of HRSGs, Waste Heat Recovery Units, and Waste

More information

FLX FLEXTUBE. The Widest Range of Hydronic and Steam Watertube Boiler Systems 1,500 to 25,000 MBTU/HR (35-600HP)

FLX FLEXTUBE. The Widest Range of Hydronic and Steam Watertube Boiler Systems 1,500 to 25,000 MBTU/HR (35-600HP) FLX FLEXTUBE The Widest Range of Hydronic and Steam Watertube Boiler Systems 1,500 to 25,000 MBTU/HR (35-600HP) Completely Integrated Boiler System Solution Flexible solutions for any application. Cleaver-Brooks

More information

SAMPLE SPECIFICATIONS

SAMPLE SPECIFICATIONS Page 1 of 6 3-03 SAMPLE SPECIFICATIONS The following sample specifications are provided by Superior Boiler Works to assist you in providing your customer with the specific needs for that application. The

More information

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired Form No. 8700 Bryan Flexible Water Tube TM Triple-Flex Series Ultra-High Efficiency Condensing Hot Water Boilers 3,000,000 BTUH Natural Gas Fired Minimum 90% Thermal Efficiency at 160 F Return with 20

More information

INDUSTRIAL WATERTUBE BOILERS

INDUSTRIAL WATERTUBE BOILERS INDUSTRIAL WATERTUBE BOILERS Innovative solutions for maximum efficiency Cleaver-Brooks Engineered Boiler Systems Manufacturers of Nebraska Boilers, NATCOM Burners and ERI HRSG Systems Industrial Watertube

More information

Boiler Basics: Design & Application Differences. Presented by Steve Connor July 30, 2014

Boiler Basics: Design & Application Differences. Presented by Steve Connor July 30, 2014 Boiler Basics: Design & Application Differences Presented by Steve Connor July 30, 2014 What We Are Covering Today Understanding Boiler Load Boiler Manufacturing Requirements Design & Construction Details

More information

Originators of the Flexible Water Tube design

Originators of the Flexible Water Tube design BRYAN FLEXIBLE WATER TUBE EB SERIES STEAM AND WATER BOILER 3,200,000 TO 10,000,000 BTUH FORCED DRAFT GAS, OIL OR DUAL FUEL FIRED Steam Boiler EB75-S-150-FDG Water Boiler EB200-W-FDGO Originators of the

More information

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. General: 1. To obtain maintenance and repair standards for boiler burners (Section 15555A) and boiler tubes (Section 15555B), contact the DPS Project

More information

Originators of the Flexible Water Tube design

Originators of the Flexible Water Tube design BRYAN FLEXIBLE WATER TUBE DR SERIES STEAM AND WATER BOILER 250,000 TO 850,000 BTUH FORCED DRAFT GAS, OIL OR DUAL FUEL FIRED Steam Boiler DR350-S-150-FDG Water Boiler DR850-W-FDGO Originators of the Flexible

More information

Williams & Davis Boilers

Williams & Davis Boilers Williams & Davis Boilers Established 1921 3-Pass Dry-Back Scotch Marine Boiler SIZES 15HP THROUGH 1500HP GAS, OIL OR COMBINATION BURNER FIRETUBE HOT WATER & PRESSURE STEAM BOILERS 3000D Standard Features

More information

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000 s AV(W)0500 AV(W) The domestic hot water boiler shall be a Camus ADVANTUS TM model having a recovery capacity of gph (lph) at 100ºF (56ºC) for DHW The domestic hot water boiler shall be design certified

More information

PACKAGED COMMERCIAL WATERTUBE BOILERS

PACKAGED COMMERCIAL WATERTUBE BOILERS PACKAGED COMMERCIAL WATERTUBE BOILERS PACKAGED COMMERCIAL WATERTUBE BOILER American Boiler Manufacturers Association 4001 N. 9 th Street, Suite 226 Arlington, VA 22203-1900 703/522-7350 2003, American

More information

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000 s AV(W)0500 AV(W) The domestic hot water boiler shall be a Camus ADVANTUS TM model having a recovery capacity of gph (lph) at 100ºF (56ºC) for DHW The domestic hot water boiler shall be design certified

More information

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section SPECIFICATION SHEETS Steam Sample Specification Water Sample Specification MOHICAN SPECIFICATION SHEET The following sample specifications are provided by Superior Boiler Works to assist you in providing

More information

Williams & Davis Boilers

Williams & Davis Boilers Williams & Davis Boilers Established 1921 3-Pass Water-Back Scotch Marine Boiler SIZES 15HP THROUGH 1500HP GAS, OIL OR COMBINATION BURNER FIRETUBE HOT WATER & PRESSURE STEAM BOILERS 3000W Standard Features

More information

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents Boiler specifications A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents Burner General: Q. Burner and burner safeguards shall comply with the CGA

More information

FUEL-FIRED VERTICAL TUBELESS BOILERS

FUEL-FIRED VERTICAL TUBELESS BOILERS FUEL-FIRED VERTICAL TUBELESS BOILERS 4 60 P orizontal and Vertical Feedwater / Condensate Return Systems and Blow-down Tanks FULTON FUEL-FIRED VERTICAL TUBELESS BOILERS FULTON: AN INDUSTRY LEADER SINCE

More information

HYDRONIC SOLUTIONS. More than just hydronic boilers, we offer the most efficient integrated hydronic solutions on the market.

HYDRONIC SOLUTIONS. More than just hydronic boilers, we offer the most efficient integrated hydronic solutions on the market. HYDRONIC SOLUTIONS More than just hydronic boilers, we offer the most efficient integrated hydronic solutions on the market. Think outside the boiler. It s time to think about your boiler room in a different

More information

MODEL M5M. High-Efficiency Packaged Watertube Boiler MMBTU

MODEL M5M. High-Efficiency Packaged Watertube Boiler MMBTU MODEL M5M High-Efficiency Packaged Watertube Boiler 2.0-6.0 MMBTU Low Emissions, High Efficiency Whether your application is a small batch load for food processing, or you are considering a hybrid heating

More information

Rental Boiler Specifications (Nebraska Boiler)

Rental Boiler Specifications (Nebraska Boiler) Rental Boiler Specifications (Nebraska Boiler) ESI's 72,000 pph trailer-mounted watertube steam boilers are designed and built in accordance with ASME Code. Each boiler is arranged for natural gas or #2

More information

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS DELTA LIMITED, TYPE WH - MODELS 399B-899B SUGGESTED SPECIFICATIONS Catalog No.: 3500.97B Effective: 04-01-17 Replaces: 11-15-08 DIVISION 23 52 33.13 FINNED WATER-TUBE WATER HEATERS - GENERAL 1.1 SUMMARY

More information

FINNED WATER-TUBE POOL HEATERS

FINNED WATER-TUBE POOL HEATERS HI DELTA, TYPE P - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 6000.611 Effective: 10-31-16 Replaces: NEW FINNED WATER-TUBE POOL HEATERS - GENERAL 1.1 SUMMARY A. Section includes gas-fired,

More information

Section B1. Flexible Watertube Boilers TABLE OF CONTENTS

Section B1. Flexible Watertube Boilers TABLE OF CONTENTS Section B1 Flexible Watertube Boilers TABLE OF CONTENTS FEATURES AND BENEFITS.................................................. B1-3 PRODUCT OFFERING......................................................

More information

Fuel-Fired Vertical Tubeless Boilers

Fuel-Fired Vertical Tubeless Boilers Fuel-Fired Vertical Tubeless Boilers Fulton Classic (4-60P), The EDGE (6-30P) orizontal and Vertical Feedwater / Condensate Return Systems and Blow-down Separators FULTON FUEL-FIRED VERTICAL TUBELESS BOILERS

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 503A-2003A SUGGESTED SPECIFICATIONS Catalog No.: 2000.932C Effective: 04-01-14 Replaces: 07-15-13 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

Boiler Basics. Design and operation

Boiler Basics. Design and operation Boiler Basics Design and operation A boiler is an enclosed vessel that provides a means for combustion heat to be transferred into water until it becomes heated water or steam. The hot water or steam under

More information

WATER-TUBE POOL HEATERS

WATER-TUBE POOL HEATERS XTHERM, TYPE P - MODELS 2505-4005 SUGGESTED SPECIFICATIONS Catalog No.: 6000.70 Effective: 09-15-16 Replaces: NEW WATER-TUBE POOL HEATERS - GENERAL 1.1 SUMMARY A. Section includes condensing, gas-fired

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 504A-2004A SUGGESTED SPECIFICATIONS Catalog No.: 2000.933C Effective: 06-25-15 Replaces: 12-21-09 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

HCLEARFIRE. High-efficiency, modular steam boiler HP

HCLEARFIRE. High-efficiency, modular steam boiler HP HCLEARFIRE High-efficiency, modular steam boiler 10-60 HP High-Efficiency, Low-Emission Steam Boiler in a Compact Footprint The ClearFire -H compact, gas-fired horizontal boiler is designed specifically

More information

WATER-TUBE POOL HEATERS

WATER-TUBE POOL HEATERS XTHERM, TYPE P - MODELS 1005A-2005A SUGGESTED SPECIFICATIONS Catalog No.: 6000.63B Effective: 3-01-15 Replaces: 9-01-09 WATER-TUBE POOL HEATERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes condensing,

More information

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS HI DELTA, TYPE WH - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 3500.932A Effective: 04-01-17 Replaces: 10-31-16 DIVISION 23 52 33.13 FINNED WATER-TUBE WATER HEATERS - GENERAL 1.1 SUMMARY A.

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 2503-4003 SUGGESTED SPECIFICATIONS Catalog No.: 2000.934A Effective: 04-01-14 Replaces: 06-01-13 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS MVB, TYPE WH - MODELS 503A-2003A SUGGESTED SPECIFICATIONS Catalog No.: 3500.952C Effective: 06-25-15 Replaces: 12-22-09 DIVISION 23 34 36.29 COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

More information

SECTION HEATING BOILERS

SECTION HEATING BOILERS SECTION 23 52 00 HEATING BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes boilers, controls and boiler trim, steam and condensate connections, hot water connections, fuel burning system and connections,

More information

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER PART 1 GENERAL 1.01 RELATED DOCUMENTS A. ANSI Z21.13 American National Standard for Gas-Fired Low Pressure Steam and Hot Water Boilers B. ASME Section

More information

CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU

CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU Unmatched Efficiency and Low-NOx Technology in a Condensing Boiler The ClearFire -C is a completely

More information

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS XTHERM, TYPE WH - MODELS 1005A- 2005A Catalog No.: 3500.801 Effective: 11-15-14 Replaces: NEW PART 1 - GENERAL 1.1 SUMMARY DIVISION 23 34 36.29 COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

More information

FINNED WATER-TUBE POOL HEATERS

FINNED WATER-TUBE POOL HEATERS HI DELTA, TYPE P - MODELS 502C-902C SUGGESTED SPECIFICATIONS Catalog No.: 6000.601A Effective: 07-12-18 Replaces: 10-31-16 FINNED WATER-TUBE POOL HEATERS - GENERAL 1.1 SUMMARY A. Section includes gas-fired,

More information

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS XPAK FT TYPE H - MODELS 088AR-398A SUGGESTED SPECIFICATIONS Catalog No.: 2100.91 Effective: 05/01/15 Replaces: new DIVISION 23 52 33.13 WALL-HUNG STAINLESS STEEL HEATING BOILERS PART 1 - GENERAL 1.1 SUMMARY

More information

Thermal Fluid Heaters

Thermal Fluid Heaters Thermal Fluid Heaters Vertical Coil, Vertical Tubeless, Electric and Horizontal Sizes from 75,000 to 40,000,000 BTU/HR The heat transfer innovators. THERMAL FLUID FEATURES AND BENEFITS KEY FEATURES No

More information

Presented by Steve Connor August 26, Boiler Choices: The What, When & Why

Presented by Steve Connor August 26, Boiler Choices: The What, When & Why Presented by Steve Connor August 26, 2015 Boiler Choices: The What, When & Why What We Are Covering Today Commercial/industrial market applications. Steam & hot water boiler types. Application decision

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS HI DELTA, TYPE H - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 2000.953 Effective: 10-31-16 Replaces: NEW DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS - GENERAL 1.1 SUMMARY A. Section includes

More information

A Newsletter published by ESI. The Steam and Power SPECIAL FORCES

A Newsletter published by ESI. The Steam and Power SPECIAL FORCES ENERGY SOURCE A Newsletter published by ESI The Steam and Power SPECIAL FORCES Spring 2003 THE BUYER S GUIDE TO PACKAGE BOILER DESIGN By: William L. Reeves, P.E., President, ESI Editor s Note: This article

More information

Cclearfire HIGH EFFICIENCY, COMPACT CONDENSING BOILER 500-3,300 MBTU

Cclearfire HIGH EFFICIENCY, COMPACT CONDENSING BOILER 500-3,300 MBTU Cclearfire HIGH EFFICIENCY, COMPACT CONDENSING BOILER 500-3,300 MBTU Unmatched efficiency and low-nox technology in a condensing boiler The ClearFire-C is a completely integrated solution with heat exchanger,

More information

Suggested Specifications Prestige Excellence 110

Suggested Specifications Prestige Excellence 110 Suggested Specifications Prestige Excellence 110 General Requirements A. Furnish and install (qty) completely assembled, modulating, sealed combustion, high efficiency, combination gas-fired boiler(s)

More information

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job SERIES Commercial, Forced Draft, Hot Water or Steam Boiler Sizes from to,8 MBH output The right fit for any commercial job The Series is built to handle any installation - businesses, institutions, apartments,

More information

Fuel-Fired Vertical Tubeless Boilers. Classic, Edge, Tribute and VMP Models From 4 to 150 BHP (138-5,021 lbs/hr)

Fuel-Fired Vertical Tubeless Boilers. Classic, Edge, Tribute and VMP Models From 4 to 150 BHP (138-5,021 lbs/hr) Fuel-Fired Vertical Tubeless Boilers Classic, Edge, Tribute and VMP Models From 4 to 150 BHP (138-5,021 lbs/hr) Fulton: An industry leader since 1949. OUR HISTORY Fulton Boiler Works, Inc. was founded

More information

Proudly assembled in U.S.A

Proudly assembled in U.S.A UP TO 85% THERMAL EFFICIENCY Versa IC Control System s 302C thru 2342C CSA certified Low Lead Content Less Than -.25% Lead Proudly assembled in U.S.A Up to 85% thermal efficiency! Raypak s Decades of expertise

More information

Revitalize Building Mechanical Systems (4619)

Revitalize Building Mechanical Systems (4619) SECTION 235216 FIRE-TUBE CONDENSING BOILERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Packaged Marine Design Thermal Fluid (Hot Oil) Heaters

Packaged Marine Design Thermal Fluid (Hot Oil) Heaters PACKAGED MARINE THERMAL FLUID (HOT OIL) HEATERS Packaged Marine Design Thermal Fluid (Hot Oil) Heaters For Heating Asphalt Barges, Tankers, And Any Other Application Requiring Dependable Heating 13 Models

More information

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s) Furnish and install as shown on AERCO International plans and operation and maintenance manuals, with all applicable codes and authorities having local, state and federal jurisdiction, Benchmark Series

More information

When you complete this module you will be able to: Describe various watertube boiler designs, including large generating units.

When you complete this module you will be able to: Describe various watertube boiler designs, including large generating units. Watertube Boilers Learning Outcome When you complete this module you will be able to: Describe various watertube boiler designs, including large generating units. Learning Objectives Here is what you will

More information

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC). SECTION 15555 HORIZONTAL FIRE TUBE BOILERS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15510 - Piping (HVAC). 2. 15540 - Pumping Equipment (HVAC). 1.02 SUBMITTALS A. Submit properly identified

More information

Silhouette. Feedwater Heater. Boiler Feedwater

Silhouette. Feedwater Heater. Boiler Feedwater Roth Roth Low Low Silhouette Silhouette TRAY DEAERATORS Boiler Boiler Feedwater Feedwater Heater Heater Capacities Capacities to to 50,000 50,000 lb/hr lb/hr Model RDTV-150-5-1-2 vertical tray type deaerator

More information

Proudly assembled in U.S.A

Proudly assembled in U.S.A Versa IC Control System s 302C thru 2342C CSA certified Low Lead Content Less Than -.25% Lead Proudly assembled in U.S.A Up to 84% thermal efficiency! Raypak s Decades of expertise and technological innovations

More information

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support: At Bradford White, we believe in giving you a feature-packed, premium product at the best possible price. We proudly build quality and value into each and every product we manufacture. We believe when

More information

DIVISION FIRE-TUBE STAINLESS STEEL HEATING BOILERS

DIVISION FIRE-TUBE STAINLESS STEEL HEATING BOILERS XVERS TYPE H - MODELS 0856-3006 SUGGESTED SPECIFICATIONS Catalog No.: 2000.84A Effective: 06/22/18 Replaces: 3/15/18 DIVISION 23 52 33.13 FIRE-TUBE STAINLESS STEEL HEATING BOILERS - GENERAL 1.1 SUMMARY

More information

Biomass Energy Systems

Biomass Energy Systems Biomass Energy Systems Direct Fired Furnaces Dieffenbacher USA has developed direct fired biomass combustion systems for dryers, lumber dry kilns, steam boilers, and thermal oil heaters. The conservative

More information

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By the Authority Vested By Part 5 of the United States Code 552(a) and Part 1 of the Code of Regulations 51 the attached document has

More information

CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH

CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH CE CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH Energy Savings and Environmental Benefits Due to its highly effective heating surface area and true counter-flow heat exchanger arrangement,

More information

Burners Flares Incinerators Vapor Combustion

Burners Flares Incinerators Vapor Combustion Burners Flares Incinerators Vapor Combustion Lower Emissions & Improve Equipment Life AIChE May 20 th, 2005 Scott D. Reed 2 Heater Components Stack & Damper Convection Section Radiant Section Burners Burner

More information

Guidelines for Preparing for a Temporary Steam Plant

Guidelines for Preparing for a Temporary Steam Plant Guidelines for Preparing for a Temporary Steam Plant Trailer-Mounted Boilers Skid Mounted Boilers Mobile Boiler Rooms Mobile Feedwater Vans Mobile Steam Plants Emergency Preparedness Plan Table of Contents

More information

Miniature Hobby Boiler Inspection and Certification Requirements

Miniature Hobby Boiler Inspection and Certification Requirements State of Washington Department of Labor & Industries Boiler & Pressure Vessel Program 7273 Linderson Way S.W. Tumwater, Washington 98501 Miniature Hobby Boiler Inspection and Certification Requirements

More information

G515/7 Cast Iron Boiler

G515/7 Cast Iron Boiler Engineering Submittal Sheet Boiler Overview Engineering Specifications There shall be provided and installed G515-7 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing with

More information

www.greenspower.com.sg 1company profile G reens Power have been at the forefront of Waste Heat Recovery Technology since Edward Green first patented the Fuel Economiser in 1845. The business developed

More information

MX RANGE PACKAGED STEAM BOILERS

MX RANGE PACKAGED STEAM BOILERS MX RANGE PACKAGED STEAM BOILERS THE MX RANGE OF THREE PASS REVERSE FLAME PACKAGED BOILERS After 35 years of constant development and improvement Byworth Boilers believes its MX range of reverse flame boilers

More information

Fuel-Fired Vertical Tubeless Boilers. Classic, Edge, Tribute and VMP Models From 4 to 150 BHP (138-5,021 lbs/hr)

Fuel-Fired Vertical Tubeless Boilers. Classic, Edge, Tribute and VMP Models From 4 to 150 BHP (138-5,021 lbs/hr) Fuel-Fired Vertical Tubeless Boilers Classic, Edge, Tribute and VMP Models From 4 to 150 BHP (138-5,021 lbs/hr) Fulton: An industry leader since 1949. OUR HISTORY Fulton Boiler Works, Inc. was founded

More information

VCLEARFIRE. High-Efficiency, Commercial Steam Boiler Horsepower

VCLEARFIRE. High-Efficiency, Commercial Steam Boiler Horsepower VCLEARFIRE High-Efficiency, Commercial Steam Boiler 9.5-60 Horsepower High-Efficiency, Low-Emissions Steam Boiler in a Compact Footprint The Cleaver-Brooks compact, gas-fired ClearFire -V vertical boiler

More information

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com Tray ST5 Pressurized and Atmospheric Deaerators Tray Type Deaerator Pressurized.005 cc/liter COUNTER FLOW TRAY design provides guaranteed removal of all dissolved oxygen in excess of.005 cc/liter from

More information

Low pressure boiler* inspection and maintenance

Low pressure boiler* inspection and maintenance 2-12.001 May 2011 Low pressure boiler* inspection and maintenance Introduction Even as our society evolves into a more technologically advanced, economically driven environment, many businesses and their

More information

Condensing Hydronic Boilers 2,000,000-6,000,000 BTU/HR

Condensing Hydronic Boilers 2,000,000-6,000,000 BTU/HR Condensing Hydronic Boilers 2,000,000-6,000,000 BTU/HR The heat transfer innovators. FEATURES High Mass and Water Volume Ultra High Efficiencies Linkageless Modulation Rugged, Robust, Reliable Duplex Alloy

More information

Raypak Residential Products

Raypak Residential Products Raypak Residential Products Raypak s Residential Boiler Product Family Raypak revolutionized the boiler market in 1948 with the first innovative high recovery boilers that utilized superior finned copper

More information

SECTION WATER-TUBE BOILERS

SECTION WATER-TUBE BOILERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections

More information

G315/6 Cast Iron Boiler

G315/6 Cast Iron Boiler Engineering Submittal Sheet Boiler Overview LISTED Engineering Specifications There shall be provided and installed G315-6 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing

More information

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh WATER HEATERS / BOILERS COWB3 Oil-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 0654 March 08 Supersedes September 05 AFUE up to 85.% Heating Input 05,000 to 45,000 Btuh MODEL NUMBER IDENTIFICATION

More information

clearfire Large capacity condensing boilers 4,000 to 12,000 MBTU/hr

clearfire Large capacity condensing boilers 4,000 to 12,000 MBTU/hr LC clearfire Large capacity condensing boilers 4,000 to 12,000 MBTU/hr Total Integration in a small footprint with unprecedented power for hydronic applications Cleaver-Brooks has raised the bar and changed

More information

Installation and Operating Instructions. Precision Flextube Boilers. FTS Series STEAM BOILERS

Installation and Operating Instructions. Precision Flextube Boilers. FTS Series STEAM BOILERS Installation and Operating Instructions Precision Flextube Boilers FTS Series STEAM BOILERS 1 Installation and Operating Instructions Precision Flextube Boilers FTS Series HOT WATER BOILERS FOR YOUR SAFETY

More information

Fast, Simple, & Easy to Use. One Company... Three Great Brands!

Fast, Simple, & Easy to Use. One Company... Three Great Brands! One Company... Three Great Brands! Ajax Boiler, Inc. designs and manufactures a comprehensive line of boiler and commercial water heating products. With over eight decades of experience, the company offers

More information

G315/5 Cast Iron Boiler

G315/5 Cast Iron Boiler Engineering Submittal Sheet Boiler Overview LISTED Engineering Specifications There shall be provided and installed G315-5 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL NVC ULTRA LOW NOx GAS BURNERS SUB 9 PPM NOx THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone: 620-421-0480,

More information

REFERENCE SYLLABUS. For FIRED PROCESS HEATER OPERATOR S. CERTIFICATE of COMPETENCY EXAMINATION AB-239. Edition 3, Revision 1, Issued

REFERENCE SYLLABUS. For FIRED PROCESS HEATER OPERATOR S. CERTIFICATE of COMPETENCY EXAMINATION AB-239. Edition 3, Revision 1, Issued For CERTIFICATE of COMPETENCY EXAMINATION AB-239 Edition 3, Revision 1, Issued 2018-07-13 Visit our Website at www.absa.ca GENERAL INMATION Introduction: As provided for under the Power Engineers Regulation,

More information

You can view our archived webinars by going to

You can view our archived webinars by going to Cleaver-Brooks Webinars Today s Topic: Six Steps for Proper Industrial Watertube Boiler Selection If you ve missed any of our previous live webinars You can view our archived webinars by going to www.cleaverbrooks.com/webinars

More information

12711 TOWNEPARK WAY / LOUISVILLE, KY / / FAX

12711 TOWNEPARK WAY / LOUISVILLE, KY / / FAX 12711 TOWNEPARK WAY / LOUISVILLE, KY 40243 800-665-4251 / 502-962-2883 / FAX 502-244-4046 THERMAL FLUID SYSTEM SPECIFICATIONS Items appearing in red are vendor data that is required with proposal. 1. Thermal

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL NVC2 THRU NVC6 ULTRA LOW NOx GAS BURNERS SUB 9 PPM NOx WITH CONTROLINKS CONTROLS THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL HOT WATER HEATING BOILERS DOMESTIC WATER HEATERS 150,000-300,000 Btu/hr MODELS EB-EWU-02 IMPORTANT INSTALLER - AFFIX INSTALLATION MANUAL ADJACENT TO THE BOILER CONSUMER - RETAIN

More information

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh HEATERS / BOILERS GWB8-E Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 065 July 06 Supersedes September 05 AFUE up to 83.9% Heating Input 50,000 to 99,000 Btuh MODEL NUMBER IDENTIFICATION

More information

G615/11 Cast Iron Boiler

G615/11 Cast Iron Boiler Engineering Submittal Sheet Boiler Overview LISTED Engineering Specifications There shall be provided and installed G615-11 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing

More information

.2 Section Waste Management and Disposal..4 Section Vibration Isolation and Seismic Control Measures.

.2 Section Waste Management and Disposal..4 Section Vibration Isolation and Seismic Control Measures. Issued 2005/06/01 Section 15510 Packaged Boilers Page 1 of 13 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3 Section 01780 Closeout

More information

PROFIRE -E SERIES BURNERS

PROFIRE -E SERIES BURNERS PROFIRE -E SERIES BURNERS 8.4-42.0 MMBTU/HR High-efficiency burner technology for the most stringent emissions requirements Integration Starts with the Burner Suitable for firetube, firebox and watertube

More information

OPERATING AND MAINTENANCE MANUAL

OPERATING AND MAINTENANCE MANUAL OPERATING AND MAINTENANCE MANUAL NVPOM-0104 TABLE OF CONTENTS Section Page 1 SPECIFICATIONS...1 1.1 Nova Plus Specifications...1-1 1.2 Warranty...1-2 2 GENERAL BURNER DESCRIPTION...2 2.1 Burner...2-1 2.2

More information

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E WATER HEATERS / BOILERS -E PRODUCT SPECIFICATIONS Gas-Fired Steam Boiler Bulletin No. 20653 September 202 Supersedes Bulletin No. 20263 AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh MODEL NUMBER

More information

Proudly assembled in U.S.A

Proudly assembled in U.S.A s HD101 thru 2342B CSA certified Low Lead Content Less Than -.25% Pb Proudly assembled in U.S.A Up to 85% thermal efficiency! Raypak s Decades of expertise and technological innovations went into creating

More information

Steam Fundamentals. (in heating & processing applications)

Steam Fundamentals. (in heating & processing applications) Steam Fundamentals (in heating & processing applications) Introduction Common Heat Energy conveyers: Thermal Oil Hot water Steam Electrical Electric Heaters Electrodes (High Current) Steam Fundamentals

More information

NOx REDUCTION EXPERIENCE ON NATURAL GAS FIRED TURBO FURNACES

NOx REDUCTION EXPERIENCE ON NATURAL GAS FIRED TURBO FURNACES NOx REDUCTION EXPERIENCE ON NATURAL GAS FIRED TURBO FURNACES by D. E. Dorman, Staff Engineer DB Riley, Inc. Presented at the International Joint Power Generation Conference Miami Beach, Florida July 23-25,

More information

Considerations for INDUSTRIAL COMBUSTION

Considerations for INDUSTRIAL COMBUSTION August 2016 Volume 23, Number 8 Considerations for INDUSTRIAL COMBUSTION Systems Follow us on: COMBUSTION CONTROLS FOR BOILERS Understand the advantages and disadvantages of combustion control schemes

More information

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h Metropolitan Steam Boiler Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing Outputs 1845-21 700 kg/h 1 Metropolitan - Steam Boiler The Metropolitan is a range of high pressure

More information

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES P R O D U C T S P E C I F I C AT I O N S W A T E R H E A T E R S / B O I L E R S CONSERVATOR Gas-Fired Steam Boiler Bulletin No. 20263 October 200 Supersedes September 2008 AFUE up to 82.7% Heating Input

More information

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER Compact Design High Recovery Energy Efficient Stainless Alloy Construction Factory Packaged Integral Safety System ASME Constructed & Stamped

More information

Trends for Radiant Tube Heated Strip Lines

Trends for Radiant Tube Heated Strip Lines WS Thermal Process Technology Inc., Elyria, Ohio WS Thermal Process Technology Inc., Elyria, Ohio Abstract WS Thermal Process Technology Inc., Elyria, Ohio Introduction After a extended period of low and

More information