Universal Clamp Meter

Size: px
Start display at page:

Download "Universal Clamp Meter"

Transcription

1 Universal Clamp Meter Instruction Manual 489D F D UniversalClampMeter Instr.indd 1 5/11/ :37:49 AM

2 Table of Contents 1. Features Specifications Designations How to Make Measurements Line Current Measurements...6,7 4.2 Leakage Current Measurements Tips Typical Causes Voltage Measurements Resistant Measurements Battery Replacement Warranty Statement F D UniversalClampMeter Instr.indd 2 5/11/ :37:49 AM

3 1. Features The 489D is a fully featured clamp meter that includes high sensitivity current, voltage and resistance measurements for RCD circuit analysis. LCD Screen LCD indication of all measurements and functions. Safety Designed Especially designed for safety throughout. No exposed metal on the external case. Double insulated to Australian and International Standards. Functional Design The 489D is so compact you can take it anywhere, yet is completely user friendly with a large rotary range switch that enables easy single-handed operation. A peak hold facility and swivel strap are also included for added convenience. Low Power Consumption Through the use of low energy circuits a single 9V battery will continuously power the instrument for approximately 200 hours. Battery Check Battery symbol is displayed on screen when battery needs replacing. 3 F D UniversalClampMeter Instr.indd 3 5/11/ :37:49 AM

4 2. Specifications Catalogue No. 489D a.c. Current Range Resolution Overload Protection 40mA 0.01mA 1A 400mA 0.1mA 10A 4A 1mA 100A 100A 0.1A 500A Accuracy Refer Page 9 40Hz - 1kHz Note: The 40mA range is very sensitive and may not give a zero reading with no current flowing in the circuit. This is normal. a.c. Voltage Range Range Resolution Overload Protection 600V 1V 1000V d.c. 750V a.c. Accuracy 50Hz - 500Hz +/- 1.5% plus 5 digits Input Impedance 10 Meg Ohm Resistance Range Range Resolution Overload Protection 400 Ohm 0.1 Ohm 500V a.c. or d.c. Accuracy +/- 1.2% plus 3 digits Maximum Open Voltage 3.3V Audible Indication Buzzer sounds if resistance is less than 100 Ohms Display 3 x 20mm digit LCD display with decimal point, measurement units, overload, low battery and peak hold on indicators. Sampling Time 2.5 times per second Operating Temperature -10 C to 50 C (less than 80% humidity) Battery Life Approximately 200 hours Dimensions 221mm x 62mm x 35mm Weight 342g Accessories Carry case, test lead set and appliance test adaptor 4 F D UniversalClampMeter Instr.indd 4 5/11/ :37:49 AM

5 3. Designations 489D Universal Clamp Meter 1. Inductive Clamp Jaw 2. Jaw Trigger 3. Peak Hold Switch 4. Frequency Select Switch 5. Rotary Range Switch 6. ON-OFF Switch 7. LCD Display 8. V/Ohm Test Socket 9. Wrist Strap Fig. 1 5 F D UniversalClampMeter Instr.indd 5 5/11/ :37:51 AM

6 4. How to Make Measurements a.c. Current Measurements Note: Before measuring current, make sure that the voltage test leads are removed from the instrument. 1. Release the peak hold and turn meter on by depressing power button. 2. Turn the range switch knob to the relevant amp. scale. 3. Press the trigger on the right side of the instrument to open the transformer jaws and encircle conductors with the transformer jaws (see example Fig. 2, A, B, C). 4. Switch meter off upon completing measurement by releasing power button. 4.1 Line Current Measurement Examples A Fig. 2 6 F D UniversalClampMeter Instr.indd 6 5/11/ :37:52 AM

7 a. Single Phase A N b. Three Phases (no neutral) c. Three Phases (plus neutral) 7 F D UniversalClampMeter Instr.indd 7 5/11/ :37:52 AM

8 4.2 Leakage Current Measurements 1. Follow steps 4(1) and (2) on page 6 and Turn range switch knob to the 40mA scale. 3. Open the transformer jaws and clamp all active and neutral conductors of the circuit under test (Fig. 2A). (For the purpose of RCD installations, leakage values greater than 5mA should be traced to their source and eliminated.) 4. To test an appliance equipped with a flexible power lead and plug, plug the appliance into the available socket via the appliance test adaptor provided with this instrument. (Fig. 3) 5. Turn the power and the appliance on, then clamp the jaws around the active and neutral loop wires on the appliance test adaptor (see Fig 3A). 6. Switch power off upon completing measurement. Appliance Test Adaptor Fig. 3 8 Fig. 3A 5. Tips for Fault Finding and Testing in RCD Installations 1. Lint collecting in the terminal enclosure of irons. 2. Accumulation of crumbs and other food particles in toasters and mini ovens. 3. Moisture accumulating in heating elements in appliances such as cookers, ovens, hot water services, urns, etc. F D UniversalClampMeter Instr.indd 8 5/11/ :37:52 AM

9 6. Typical Causes of Leakage Current in Fixed Wiring 1. Additional M.E.N. points downstream of the RCD. 2. Incorrect wiring of socket outlets or light points (eg. neutral and earth exchanged). 3. Use of neutral or active from non RCD protected circuits to power loads in an RCD protected circuit. a.c. Current Range Resolution Accuracy 40Hz - 1kHZ Overload Protection *40mA 0.01mA +/-1.5%+2 1A 400A 0.1mA +/-5.0% 10A 4A 1mA +/-1.5%+2 100A 100A 0.1A +/-2%+2 500A *40mA range is very sensitive and may not give zero reading with no current flowing in CT. This is normal. 7. Voltage Measurements 1. Release the peak hold and turn meter on by depressing power button. 2. Plug the red test lead into the VOLT terminal and the black test lead into the COM terminal. 3. Turn the range switch knob to the 600V scale. 4. Bring one of the test leads in contact with one side of the circuit under test and the other with the other side. 5. Switch meter off upon completing measurement by releasing power button. a.c. Voltage Range Resolution Accuracy 50Hz - 500Hz Overload Protection 600V 1V +/-1.5%+5 d.c.1000v a.c. 750V Input Impedance 10Meg Ohm 9 F D UniversalClampMeter Instr.indd 9 5/11/ :37:52 AM

10 8. Resistance Measurements 1. Release the peak hold and turn meter on by depressing power button. 2. Turn the range switch knob to the Ohm scale. 3. Insert black banana plug of the voltage test leads into the COM terminal. Then, insert the red banana plug into the red terminal. 4. As shown in Fig. 4 connect the test leads to the circuit under test for resistance measurements. 5. Switch meter off upon completing measurement by releasing power button. Resistance Range Resolution Accuracy Hz Overload Protection 400 Ohm 0.1 Ohm +/- 1.2%+3 a.c./d.c. 500Vrms Buzzer sounds if resistance is less than 100 Ohm. Max. Open Voltage 3.3V 9. Battery Replacement Remove battery cover, (Phillips Head screw) and slide off. Replace with battery or equivalent as per Fig F D UniversalClampMeter Instr.indd 10 5/11/ :37:54 AM

11 10. Warranty Statement The benefits conferred by this warranty are in addition to all implied warranties, other rights and remedies in respect of the product which the consumer has under the Trade Practices Act and similar State and Territory Laws. The original purchaser of this Universal Clamp Meter, is provided with the following warranty, subject to the following conditions: Clipsal Australia warrant this product for a period of 1 year from the date of purchase for all parts defective in workmanship or materials. All defective parts will be replaced or repaired free of charge. The following exclusions do not preclude the purchaser from those statutory rights consumers have under the Trade Practices Act or similar State and Territory Laws. Warranty Conditions 1. The instrument must be used by a competent, trained person and operated in strict accordance with the instructions. Clipsal Australia Pty Ltd will not accept liability for any damage or injury caused by misuse or non-compliance with the instructions. 2. Warrant will only be given where proof of purchase date is provided. e.g. original invoice or copy. 3. This instrument must not be modified or changed in any way. IMPORTANT: Please retain this warranty. You must retain your original purchase receipt, otherwise you will be charged at current rates. Purchased from: Company Name Address Date of Purchase 11 F D UniversalClampMeter Instr.indd 11 5/11/ :37:54 AM

12 Technical Support and Troubleshooting For technical assistance call: Worldwide contacts: Information and resources: (Australia) (New Zealand) clipsal.com/locations clipsal.com/cis Product of Clipsal Australia Pty Ltd ABN Park Terrace, Bowden, South Australia 5007 Telephone (08) Facsimile (08) National Customer Service Enquiries: Tel Fax clipsal.com Clipsal Australia Pty Ltd reserves the right to change specifications, modify designs and discontinue items without incurring obligation and whilst every effort is made to ensure that descriptions, specifications and other information in this catalogue are correct, no warranty is given in respect thereof and the company shall not be liable for any error therein. Copyright Clipsal Australia Pty Ltd All rights reserved. F1365/04 CLIPCOM/ F D UniversalClampMeter Instr.indd 12 5/11/ :37:55 AM

Ceiling Mounted Ducted Exhaust Fan Kit

Ceiling Mounted Ducted Exhaust Fan Kit Ceiling Mounted Ducted Exhaust Fan Kit Installation Instructions CEF40WK CONTINUOUS OPERATION RESIDENTIAL APPLICATIONS Table of Contents Included With This Fan...3 Not Included With This Fan...3 Before

More information

Mains Power Filter 970MF10 970MF20. Installation Instructions

Mains Power Filter 970MF10 970MF20. Installation Instructions Mains Power Filter Installation Instructions and Table of Contents 1.0 Warnings... 3 2.0 Introduction... 3 3.0 Quick Installation Overview... 3 4.0 Typical Installations... 3 5.0 Protection Concepts...

More information

Push Button Electronic Timer. 31VETR Series. Installation Instructions

Push Button Electronic Timer. 31VETR Series. Installation Instructions Push Button Electronic Timer Series Installation Instructions Contents 1.0 Product Range... 3 2.0 Description... 3 3.0 Features... 3 4.0 Important Warnings... 3 5.0 Timer Control... 4 5.1 Push Button Control...

More information

Push Button Electronic Timer. 31VETR3 Series. Installation Instructions

Push Button Electronic Timer. 31VETR3 Series. Installation Instructions Push Button Electronic Timer 31VETR3 Series Installation Instructions Contents 1.0 Product Range... 3 2.0 Description... 3 3.0 Features... 3 4.0 Important Warning... 3 5.0 Timer Control... 4 5.1 Push Button

More information

C-Bus Black & White MK II Touch Screen. 5000CT2 Series. User s Guide

C-Bus Black & White MK II Touch Screen. 5000CT2 Series. User s Guide C-Bus Black & White MK II Touch Screen 5000CT2 Series Clipsal is a registered trademark of Clipsal Australia Pty Ltd ABN 27 007 873 529. Neo is a registered Trademark of Clipsal Australia Pty Ltd. Copyright

More information

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL Clipsal and C-Bus are registered trademarks of Clipsal Australia Pty Ltd ABN 27 007 873 529. Copyright Clipsal Australia Pty Ltd 2008. All rights reserved.

More information

C-Bus Black & White MK II Desktop Touchscreen. 5000CTD2 Series. User s Guide REGISTERED DESIGN REGISTERED PATENT

C-Bus Black & White MK II Desktop Touchscreen. 5000CTD2 Series. User s Guide REGISTERED DESIGN REGISTERED PATENT C-Bus Black & White MK II Desktop Touchscreen 5000CTD2 Series REGISTERED DESIGN REGISTERED PATENT Clipsal is a registered trademark of Clipsal Australia Pty Ltd ABN 27 007 873 529. C-Bus is a registered

More information

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions C-Bus Pascal Automation Controller 5500PACA Installation Instructions Contents 1.0 Description...3 2.0 Important Notes...3 3.0 Capabilities...3 4.0 Wiring Instructions...4 4.1 Battery Back up...5 4.2 Connecting

More information

QUICKSMART Universal Exit Light EXITSM. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

QUICKSMART Universal Exit Light EXITSM. Installation Instructions REGISTERED DESIGN REGISTERED PATENT QUICKSMART Universal Exit Light EXITSM Installation Instructions REGISTERED DESIGN REGISTERED PATENT Table of Contents 1.0 Welcome...3 2.0 Safety Warnings...3 3.0 Installation Instructions... 4-5 4.0 Maintaining

More information

F Type Shielded Masthead Amplifier 3105MH35U18V DIGITAL TERRESTRIAL TELEVISION READY. Installation Instructions

F Type Shielded Masthead Amplifier 3105MH35U18V DIGITAL TERRESTRIAL TELEVISION READY. Installation Instructions F Type Shielded lifier DIGITAL TERRESTRIAL TELEVISION READY Installation Instructions F Type Shielded lifier Installation Instructions 1.0 Features For outdoor use. F Type connection with low noise and

More information

Trailing Edge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Trailing Edge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT Trailing Edge Dimmer 32E450T Series Installation Instructions REGISTERED DESIGN REGISTERED PATENT Table of Contents 1.0 Product Range...3 2.0 Description...3 3.0 Features...3 4.0 Load Compatibility...4

More information

Evaporative Cooler. 8 Litre MEC1R

Evaporative Cooler. 8 Litre MEC1R Evaporative Cooler 8 Litre MEC1R Important Safeguards When using electrical appliances, in order to reduce the risk of fire, electric shock and/or injury, these basic safety precautions should always be

More information

Wall Fan. 3 Speed, 40cm MWF40

Wall Fan. 3 Speed, 40cm MWF40 Wall Fan 3 Speed, 40cm MWF40 Important Safeguards When using electrical appliances, in order to reduce the risk of fire, electric shock and/or injury, these basic safety precautions should always be followed:

More information

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V Universal Dimmer Integrally Switched Rotary Controlled 31E2RUD Series ROTARY CONTROL INTEGRALLY SWITCHED 240V 450W Installation Instructions REGISTERED DESIGN REGISTERED PATENT Table of Contents 1.0 Product

More information

Consumer Switchboards 4CS & 4FCS. Installation Instructions

Consumer Switchboards 4CS & 4FCS. Installation Instructions Consumer Switchboards 4CS & 4FCS Installation Instructions Table of Contents 1.0 Dimensions...3 1.1 4CS Series Surface Mounting Consumer Switchboard Dimensions in mm...3 1.2 4FCS Series Flush Mounting

More information

Line Isolation & Overload Monitor. E05 Series. Installation Instructions MU TE TE S T E. S.P. ALARM MUT E D OVE R LOAD WAR NING PHC WARNING

Line Isolation & Overload Monitor. E05 Series. Installation Instructions MU TE TE S T E. S.P. ALARM MUT E D OVE R LOAD WAR NING PHC WARNING MU TE ALARM MUT E D OVE R LOAD WAR NING E. S.P. E0 5 LI NE IS OLATION AND OVERLOAD MONITOR 9 6 5 ma 8 7 4 3 2 1 PO W E R PR OSPE CTIVE HAZ ARD CUR RENT LEVE L TE S T PHC WARNING Line Isolation & Overload

More information

Pedestal Fan. 12 months. 3 Speed, 40cm R2000B

Pedestal Fan. 12 months. 3 Speed, 40cm R2000B 3 Speed, 40cm R2000B 12 months Important Safeguards When using electrical appliances, in order to reduce the risk of fire, electric shock, and/or injury, these basic safety precautions should always be

More information

TrailingE dge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

TrailingE dge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT TrailingE dge Dimmer 32E450T Series Installation Instructions REGISTERED DESIGN REGISTERED PATENT Table of Contents 1.0 Product Range...3 2.0 Description...3 3.0 Features...3 4.0 Load Compatibility...4

More information

INDOOR INFRASCAN. Passive Infrared Motion Sensors 751 SERIES INSTALLATION MANUAL. Please leave these instructions at the installation site

INDOOR INFRASCAN. Passive Infrared Motion Sensors 751 SERIES INSTALLATION MANUAL. Please leave these instructions at the installation site INDOOR INFRASCAN Passive Infrared Motion Sensors 751 SERIES INSTALLATION MANUAL Please leave these instructions at the installation site Contents Section...Page 1 Product Range...3 2 Description...3 3

More information

Three Speed Capacitive Fan Controller. 4060CSFM Series. Installation Instructions 75VA

Three Speed Capacitive Fan Controller. 4060CSFM Series. Installation Instructions 75VA 0 Three Speed Capacitive Fan Controller 4060CSFM Series 75VA Installation Instructions Table of Contents 1.0 Product Range...3 2.0 Description...3 3.0 Features...3 4.0 Load Compatibility...4 4.1 Controlling

More information

Iconic Series ControlLink Pushbutton 41EPBM-VW PDL356PBSS-VW. Installation Instructions REGISTERED DESIGN

Iconic Series ControlLink Pushbutton 41EPBM-VW PDL356PBSS-VW. Installation Instructions REGISTERED DESIGN Iconic Series ControlLink Pushbutton 41EPBM-VW PDL356PBSS-VW Installation Instructions REGISTERED DESIGN Copyright Notice The concepts, products and designs described in this document are the subject of

More information

Dimmer / Fan Controller Installation Instructions

Dimmer / Fan Controller Installation Instructions Dimmer / Fan Controller Installation Instructions US P P H US US H U S H O N N -- - - - - F O F FF Table of Contents Section... Page 1.0 Product Range...3 2.0 Description...3 3.0 Features...3 3.1 Soft

More information

WAFER Recessed Edgelite Exit LED EXITREC. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

WAFER Recessed Edgelite Exit LED EXITREC. Installation Instructions REGISTERED DESIGN REGISTERED PATENT WAFER Recessed Edgelite Exit LED EXITREC Installation Instructions REGISTERED DESIGN REGISTERED PATENT Table of Contents 1.0 Welcome...3 2.0 Safety Warnings...3 3.0 Installation Instructions...4 4.0 Maintaining

More information

Wireless Electricity Monitor. User Manual REGISTERED PATENT

Wireless Electricity Monitor. User Manual REGISTERED PATENT Wireless Electricity Monitor User Manual REGISTERED PATENT 1.0 Introduction Thank you for selecting the Clipsal Centameter Wireless Electricity Monitor. Keeping an eye on your electrical usage has never

More information

Get connected with Xantrex Grid-Tie Inverters

Get connected with Xantrex Grid-Tie Inverters Get connected with Xantrex Grid-Tie Inverters Available in 2800 or 5000 watt power output. Redefining the grid-tie inverter is a tall order, but that s exactly what Clipsal have done with their Xantrex

More information

Light Level Detector, Surface Mount 5754PE. Installation Instructions

Light Level Detector, Surface Mount 5754PE. Installation Instructions Light Level Detector, Surface Mount 5754PE Contents 1.0 Introduction 3 2.0 Safety and Product Handling 3 3.0 Installation 4 3.1 Removing the Top Cover 4 3.2 Installing the Mounting Hardware 4 3.3 Mounting

More information

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V ROTARY CONTROL INTEGRALLY SWITCHED 240V Universal Dimmer Integrally Switched Rotary Controlled 31E2RUD Series Installation Instructions REGISTERED DESIGN REGISTERED PATENT Table of Contents 1.0 Product

More information

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd. Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd. Copyright Clipsal Australia Pty Ltd, 2008. All rights reserved. This material is copyright

More information

DON T WAIT UNTIL IT S TOO LATE! Discover the seven steps to a safe and secure home.

DON T WAIT UNTIL IT S TOO LATE! Discover the seven steps to a safe and secure home. DON T WAIT UNTIL IT S TOO LATE! Discover the seven steps to a safe and secure home. Don t become a statistic Australia has one of the world s safest environments, yet electricity and our surroundings still

More information

PAC1500Xi PORTABLE APPLIANCE CHECKER

PAC1500Xi PORTABLE APPLIANCE CHECKER PAC1500Xi PORTABLE APPLIANCE CHECKER OPERATING INSTRUCTIONS 211A912 CONTENTS 1) Safety... 1 2) Introduction & Description... 2 3) Applications... 2 4) Test Sequence... 3 5) Visual Inspection... 3 6) Earth

More information

Indoor Infrascan Passive Infrared Motion Sensor. Series. Installation Instructions. Please leave these instructions at the installation site.

Indoor Infrascan Passive Infrared Motion Sensor. Series. Installation Instructions. Please leave these instructions at the installation site. Indoor Infrascan Passive Infrared Motion Sensor 751 Series Installation Instructions Please leave these instructions at the installation site. Table of Contents 1.0 Product Range...3 2.0 Description...3

More information

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions Ceiling-Mounted Motion Detector 752/CD, 752/CP, 752/CU and 752/Cx180 Installation Instructions Contents 1.0 Description...3 1.1 Contents of the Box...3 2.0 Safety...4 3.0 Coverage Patterns...4 3.1 PIR

More information

HIGH VOLTAGE A.C. PROXIMITY DETECTOR HI-PROX

HIGH VOLTAGE A.C. PROXIMITY DETECTOR HI-PROX HIGH VOLTAGE A.C. PROXIMITY DETECTOR HI-PROX T275HP United States Design Patent : US D474, 705 S INSTRUCTION MANUAL INDEX PAGE Safety Rules... 01 General Description... 02 Low Voltage Testing... 03 Front

More information

60cm Built-In Ceramic Cooktop

60cm Built-In Ceramic Cooktop 20130304 issue 8 啊哈 60cm Built-In Ceramic Cooktop Installation and User manual Content Safety instructions-----------------------------------2 Features of your product---------------------------4 Installing

More information

Mini. Level Control systems For Manual Sump Pumps up to 750W 1 or 2 Pump Systems

Mini. Level Control systems For Manual Sump Pumps up to 750W 1 or 2 Pump Systems SumpMaster Mini Level Control systems For Manual Sump Pumps up to 750W 1 or 2 Pump Systems Please pass these instructions on to the operator of this equipment. 1 DSM-Mini-0.4 = 10A combined Max DSM-Mini-0.75

More information

Universal Dimmer E450UD Series. Installation Instructions

Universal Dimmer E450UD Series. Installation Instructions Universal Dimmer E450UD Series Installation Instructions Table of Contents... 3... 3... 3... 4... 4... 5... 5 6.1 Wiring Details... 5 6.2 Soft-Start Feature... 5 6.3 Minimum Brightness Settings... 5 6.4

More information

TESTSAFE. minipat APPLIANCE TESTER USER MANUAL

TESTSAFE. minipat APPLIANCE TESTER USER MANUAL TESTSAFE minipat APPLIANCE TESTER USER MANUAL TABLE OF CONTENTS SAFETY RULES 3 GENERAL DESCRIPTION 4-9 Overall Result 4 Earthing and Class I Appliances 5 Overall Result Class I Appliances and Cables 5

More information

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series Installation Instructions Contents 1.0 Product Range...3 2.0 Principle of Operation...3 3.0 Field of View...3 4.0 System Components

More information

Blender. brushed stainless steel housing BTBL55

Blender. brushed stainless steel housing BTBL55 Blender brushed stainless steel housing BTBL55 Important Safeguards When using electrical appliances, in order to reduce the risk of fire, electric shock and/or injury,these basic safety precautions should

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS MANUFACTURED BY ROBAND AUSTRALIA PTY LTD OPERATING INSTRUCTIONS HOT DOG STEAMER MODELS: M1 VERSION 1 UNITS These instructions cover the models of ROBAND Hot Dog Units listed above. Although there are slight

More information

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL Analox Sensor Technology Ltd 15 Ellerbeck Court Stokesley Business Park Stokesley TS9 5PT Tel: +44 (0)1642 711400 Fax: +44 (0)1642 713900 Email: info@analox.net

More information

Passive Infrared Motion Detector 5420/90P. Installation Instructions

Passive Infrared Motion Detector 5420/90P. Installation Instructions Passive Infrared Motion Detector Installation Instructions 5420/90P The 5420/90P Passive Infrared Motion Detector provides reliable, high performance detection at an affordable price. The Detector features

More information

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents GasGuard H 2-1% General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6 Operation..

More information

Ohm Metrics. Instruction Manual. Model CM400 Series. Continuous Workstation Monitors

Ohm Metrics. Instruction Manual. Model CM400 Series. Continuous Workstation Monitors T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L Ohm Metrics Continuous Workstation Monitors TRANSFORMING TECHNOLOGIES,

More information

INSTRUCTION MANUAL / INSTALLATION MANUAL. 7kg Vented Dryer MODEL: KA7VENTDRYA

INSTRUCTION MANUAL / INSTALLATION MANUAL. 7kg Vented Dryer MODEL: KA7VENTDRYA INSTRUCTION MANUAL / INSTALLATION MANUAL 7kg Vented Dryer MODEL: KA7VENTDRYA THIS PAGE IS INTENTIONALLY LEFT BLANK 2 CONTENTS Safety Instructions 4 Your Kogan Vented Dryer 5 Before First Use 5 Accessory

More information

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120. MariGlo LED 45 / 60 / 90 / 120 Inspiring Excellence in Fish Keeping! Instruction version: 01/10/2013 Important Safeguards To guard against injury, basic safety precautions should be observed, including

More information

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L C-Bus PIR Occupancy Sensor Installation Instructions 5751L Contents 1.0 Description 3 2.0 Important Notes 3 3.0 Installation 3 4.0 C-Bus Network Connection 6 5.0 Programming and Setup 7 6.0 Troubleshooting

More information

WITH OMRON E5CC CONTROL

WITH OMRON E5CC CONTROL LABORATORY OVENS, FAN FORCED & GRAVITY CONVECTION. MODELS: TO-152G & TOH-152G TO-152F, TOH-152F & TO-235F TO-330F & TO-500F WITH OMRON E5CC CONTROL Thermoline Scientific Equipment Pty. Ltd. T/A Thermoline

More information

TRAVELMATE FRIDGE FREEZER Instruction Manual

TRAVELMATE FRIDGE FREEZER Instruction Manual Nexberg Pty Ltd T/a Evakool 16 Enterprise St CALOUNDRA QLD 4551 Tel : 07 5492 7777 Fax : 07 5492 7733 Please read these instructions and the Safety section carefully before using your refrigerator. 1.Safety

More information

3 963/963E Benchtop Air Ionizer Instructions

3 963/963E Benchtop Air Ionizer Instructions 3 963/963E Benchtop Air Ionizer Instructions Index Section Page Safety Information...4 1. Description...5 2. Performance...5 3. Power Requirements...5 4. Installation...5 5. Operation...6 6. Maintenance...6

More information

Dome Kettle. polished stainless steel body BTDK120

Dome Kettle. polished stainless steel body BTDK120 Dome Kettle polished stainless steel body BTDK120 Important Safeguards When using electrical appliances, in order to reduce the risk of fire, electric shock and/or injury, these basic safety precautions

More information

Instruction Manual. Please read these instructions and the Safety section carefully before using your refrigerator.

Instruction Manual. Please read these instructions and the Safety section carefully before using your refrigerator. Nexberg Pty Ltd T/a Evakool 16 Enterprise St CALOUNDRA QLD 4551 Tel : 07 5492 7777 Fax : 07 5492 7733 Please read these instructions and the Safety section carefully before using your refrigerator. 1.Safety

More information

OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN

OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN Thermoline Scientific Equipment Pty. Ltd. ABN 80 000 859 129 10-12 Ross Place Wetherill Park NSW 2164. P.O. Box 1851 Wetherill

More information

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK Analox 1000 Series User Manual Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK T: +44 (0)1642 711400 F: +44 (0)1642 713900 W: www.analox.net E: info@analox.net

More information

for LABORATORY REFRIGERATOR MODEL TELR-145/ L/200L CAPACITY REVISION

for LABORATORY REFRIGERATOR MODEL TELR-145/ L/200L CAPACITY REVISION for LABORATORY REFRIGERATOR MODEL TELR-145/200 145L/200L CAPACITY REVISION 10-8-17 Thermoline Scientific Equipment Pty. Ltd. ABN 80 000 859 129 10/12 Ross Place Wetherill Park NSW 2164. P.O. Box 1851 Wetherill

More information

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

GG-EM ENTRANCE MONITOR. Installation and Operation Manual GG-EM ENTRANCE MONITOR Installation and Operation Manual 2 GG-EM Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

SAFETY PERSONAL AC VOLTAGE (50 or 60Hz) PROXIMITY DETECTOR

SAFETY PERSONAL AC VOLTAGE (50 or 60Hz) PROXIMITY DETECTOR SAFETY PERSONAL AC VOLTAGE (50 or 60Hz) PROXIMITY DETECTOR INSTRUCTION MANUAL Index 1. Safety rules... 2. General description... 3. Principle of how it works... 4. Check it and get it going... a. Check

More information

TRAVELMATE. Instruction Manual

TRAVELMATE. Instruction Manual Nexberg Pty Ltd T/a Evakool 16 Enterprise St CALOUNDRA QLD 4551 Tel : 07 5492 7777 Fax : 07 5492 7733 Please read these instructions and the Safety Instructions carefully before using your refrigerator.

More information

INSTALLATION & OPERATION INSTRUCTIONS

INSTALLATION & OPERATION INSTRUCTIONS INSTALLATION & OPERATION INSTRUCTIONS Built-In Drawer Refrigerator Model No. BRE133BI FINELINE: 5104015 V.5 APR18 For Warranty and technical queries: 1300 373 199 Aust OR 0508123108 NZ www.belliniappliances.com.au

More information

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual GG-NH3-2% AMMONIA GAS SENSOR Installation and Operation Manual 2 GG-NH3-2% Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

4 Slice Stainless Steel Toaster T386D. instruction manual REHEAT DEFROST CANCEL MONTH WARRANTY

4 Slice Stainless Steel Toaster T386D. instruction manual REHEAT DEFROST CANCEL MONTH WARRANTY 4 Slice Stainless Steel Toaster T386D instruction manual REHEAT DEFROST CANCEL 12 MONTH WARRANTY REHEAT DEFROST CANCEL T386D IMPORTANT SAFETY INSTRUCTIONS... 1 CONTROLS AND FEATURES... 4 UNPACKING... 5

More information

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL GASGUARD LEL 3 Ammonia Sensor OPERATING & INSTALLATION MANUAL GasGuard LEL 3 Operating and Installation Manual 2 Table of Contents 3GasGuard LEL Operating and Instruction Manual General description. 4

More information

OPERATING INSTRUCTIONS FOR:

OPERATING INSTRUCTIONS FOR: OPERATING INSTRUCTIONS FOR: MODEL: BL-30 & BL-130 REFRIGERATED BATH Thermoline Scientific Equipment Pty. Ltd. ABN 80 000 859 129 10-12 Ross Place Wetherill Park NSW 2164. P.O. Box 1851 Wetherill Park DC

More information

Instuction Booklet. 4 Slice Toaster - TA9400 / Slice Toaster - TA9200 / 9205

Instuction Booklet. 4 Slice Toaster - TA9400 / Slice Toaster - TA9200 / 9205 4 Slice Toaster - TA9400 / 9405 Slice Toaster - TA900 / 905 Instuction Booklet Please read these instructions carefully and retain for future reference TA9400_TA9405_17EM.indd 1 5/10/17 10:35 Contents

More information

Instuction Booklet. 4 Slice Toaster - TA9400 / Slice Toaster - TA9200 / 9205

Instuction Booklet. 4 Slice Toaster - TA9400 / Slice Toaster - TA9200 / 9205 4 Slice Toaster - TA9400 / 9405 2 Slice Toaster - TA9200 / 9205 Instuction Booklet Please read these instructions carefully and retain for future reference Contents Sunbeam s Safety Precautions 2 Features

More information

Ohm Metrics. Instruction Manual. Continuous Workstation Monitors Model CM1600. T r a n s f o r m i n g T e c h n o l o g i e s, L L C

Ohm Metrics. Instruction Manual. Continuous Workstation Monitors Model CM1600. T r a n s f o r m i n g T e c h n o l o g i e s, L L C O u t s t a n d i n g A l t e r n a t i v e s i n S t a t i c C o n t r o l T r a n s f o r m i n g T e c h n o l o g i e s, L L C Ohm Metrics Continuous Workstation Monitors Model CM1600 Instruction Manual

More information

Figure 1. Figure 2. See notes 1 and 2 below.

Figure 1. Figure 2. See notes 1 and 2 below. 273 Branchport Avenue Long Branch, N.J. 07740 (800) 631-2148 Thank you for using our products. www.wheelockinc. com INSTALLATION INSTRUCTIONS HORN SPEAKER WITH AMPLIFIER Use this product according to this

More information

Instruction Manual. By Evakool. Please read these instructions and the Safety section carefully before using your refrigerator.

Instruction Manual. By Evakool. Please read these instructions and the Safety section carefully before using your refrigerator. Nexberg Pty Ltd T/a Evakool 16 Enterprise St CALOUNDRA QLD 4551 Tel : 07 5492 7777 Fax : 07 5492 7733 Please read these instructions and the Safety section carefully before using your refrigerator. 1.Safety

More information

A2CM2 Dual Wire Continuous Resistance Monitor

A2CM2 Dual Wire Continuous Resistance Monitor A2CM2 Dual Wire Continuous Resistance Monitor Instruction Manual BOKAR International 10 Enterprise Drive Carbondale, PA 18407, USA Tel: (570) 842-2812 Fax: (570) 842-4290 E-mail: bokar@bomir.com www.bokar.com

More information

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual GG-H2S HYDROGEN SULFIDE GAS SENSOR Installation and Operation Manual 2 GG-H2S Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by

More information

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL GASGUARD Cl 2 Chlorine Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual 2 Table of Contents GasGuard Cl 2 Operating and Instruction Manual General description. 4 Installation..

More information

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL GASGUARD O 2 Oxygen Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6 Operation.. 7 Start-up...

More information

754 Series. See Motion Sensors. in a new light. Sleek new styling and more features than ever before.

754 Series. See Motion Sensors. in a new light. Sleek new styling and more features than ever before. See Motion Sensors in a new light. Sleek new styling and more features than ever before. Clipsal s new Outdoor Infrascan range won t leave you in the dark. The new 754 Series Outdoor Infrascan Range is

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 High Water Alarm WA400-DC WA400-AC WA400-BU WA400-FS WA400-AL 10/23/06 P/N: 01-527

More information

www. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection

www. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection Ground Fault Protection GADD MKIII Ground Fault Indication System Instruction Manual 7615 Kimbel Street, Mississauga, Ontario Canada L5S 1A8 Tel: (905)673-1553 Fax: (905)673-8472 Toll Free: 1-888-RESISTR

More information

Parts Identification and Accessories Safety Information Installation Control Panel Layout Fully Automatic Washing...

Parts Identification and Accessories Safety Information Installation Control Panel Layout Fully Automatic Washing... INDEX Parts Identification and Accessories.................................... 2 Safety Information................................................. 3 Installation.......................................................

More information

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual Warning Use this product only in the manner described in this manual. If the equipment is used in a

More information

RSA2CL6SS model pictured

RSA2CL6SS model pictured Issue: 1 Description: Model Numbers: ROBINHOOD SLIDEOUTS RSA2CL6SS RSA2CL9SS RSA2CL6SS model pictured 1 Overview * All dimensions shown above are in mm and apply to 600mm and 900mm models Pre-installation

More information

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents GasGuard NH 3 2% General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6

More information

Energy cost saving made easy!

Energy cost saving made easy! Energy cost saving made easy! The Clipsal Energy Controller The most you ll ever save with the lights on. The Clipsal Energy Controller saves up to 30% of power used by fl uorescent lights, with minimal

More information

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual GG-NO2 NITROGEN DIOXIDE GAS SENSOR Installation and Operation Manual 2 GG-NO2 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by

More information

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR 1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR IMPORTANT: Please read these installation and operating instructions completely and carefully before

More information

1.7L KETTLE INSTRUCTION MANUAL 220~240V 2200W

1.7L KETTLE INSTRUCTION MANUAL 220~240V 2200W 1.7L KETTLE INSTRUCTION MANUAL 220~240V 2200W WHKE01 2200W CONTENTS SAFETY INFORMATION Important Safety Instructions......................... 1-2 Electrical Requirements................................

More information

Pure Glass. saturn.clipsal.com

Pure Glass. saturn.clipsal.com Pure Glass. saturn.clipsal.com Pure glass. Stylish in appearance and clever in design, Clipsal s new Saturn switch is beautifully crafted from pure glass, giving it a smooth reflective face and a style

More information

Consumer Products Catalog

Consumer Products Catalog Consumer Products Catalog C O N T R O L S Home Monitoring & Lighting This affordable line from Reliance Controls permits you to monitor your home or cabin for power outages, flooding, temperature drop

More information

Intercom Systems Video Intercoms

Intercom Systems Video Intercoms 8.0 International Offices CHINA Clipsal China Ltd Tel: +86 755 8237 5577 Fax: +86 755 8237 5576 sales@c-bus.com.cn GEORGIA Clipsal Contact Tel: +995 32 65 5599 Fax: +995 32 65 6699 clipsalcontact@gol.ge

More information

C-Bus Four Channel General Input Unit Installation Instructions

C-Bus Four Channel General Input Unit Installation Instructions C-Bus Four Channel General Input Unit Installation Instructions 5504GI Series REGISTERED DESIGN REGISTERED PATENT Table of Contents Section...Page 1.0 Product Range... 3 2.0 Description... 3 3.0 Capabilities...

More information

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL. Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL www.aquaticsentry.com TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 3 2. APPLICATION... 3 2.1 HIGH AND LOW LEVEL ALARM 2.2 PUMP DOWN CONTROLLER 2.3

More information

LABORATORY ILLUMINATED FLOTATION BATH

LABORATORY ILLUMINATED FLOTATION BATH LABORATORY ILLUMINATED FLOTATION BATH MODELS INCLUDE: TFB-1 Thermoline Scientific Equipment Pty. Ltd. ABN 80 000 859 129 10-12 Ross Place Wetherill Park NSW 2164. P.O. Box 6862 Wetherill Park DC NSW 1851

More information

1022 R/T Remote Monitor

1022 R/T Remote Monitor 1022 R/T Remote Monitor INSTRUCTIONS AMC-1022R/T WITH REMOTE SENSOR OR TRANSMITTER INSTALLATION AND OPERATING INSTRUCTIONS FOR THE AMC-1022R/T UNIT IMPORTANT: Please read these installation and operating

More information

GG-R REFRIGERANT SENSOR. Installation and Operation Manual

GG-R REFRIGERANT SENSOR. Installation and Operation Manual GG-R REFRIGERANT SENSOR Installation and Operation Manual 2 GG-R Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

Airflow. Add a little Sunshine to your bathroom

Airflow. Add a little Sunshine to your bathroom Airflow Add a little Sunshine to your bathroom clipsal.com Airflow Sunshine 2 x 275W heat-lamp model 6600A The 6600A is suitable for small bathrooms and en suites with ceilings of average height 2.7 metres

More information

MLHG6-AU. Iso-Gard Line Isolation Monitor (LIM) Setup Guide ! WARNING. Components

MLHG6-AU. Iso-Gard Line Isolation Monitor (LIM) Setup Guide ! WARNING. Components Iso-Gard Line Isolation Monitor (LIM) MLHG6-AU Setup Guide This document is intended as a guide for the basic physical setup of the Line Isolation Monitor (LIM). This document includes wiring diagrams

More information

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual GG-NH3 AMMONIA GAS SENSOR Installation and Operation Manual 2 GG-NH3 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL GASGUARD H2S EXP Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual Warning Use this product only in the manner described in this manual. If the equipment is used

More information

USER MANUAL. Adventure Kings 50L Refrigerator

USER MANUAL. Adventure Kings 50L Refrigerator Adventure Kings 50L Refrigerator USER MANUAL Please read and understand these instructions and the safety information section before using your refrigerator. CONTENTS Safety Information 1 Notes on using

More information

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc. Installation Manual M-000 Setpoint Thermostat Version.04 M-000 HBX Control Systems Inc. TABLE OF CONTENTS Introduction Index Safety symbols and Warnings Index Receipt and Inspection Description Technical

More information

6.5L SLOW COOKER INSTRUCTION MANUAL

6.5L SLOW COOKER INSTRUCTION MANUAL 6.5L SLOW COOKER INSTRUCTION MANUAL 220~240V 320W WHSC01SS 320W CONTENTS SAFETY INFORMATION Important Safety Instructions......................... 1-2 Electrical Requirements................................

More information

Motion sensors for every application

Motion sensors for every application Motion sensors for every application Convenience, safety and security Motion s and Security Lighting. Switch on to security, safety and savings The Clipsal Kinesis 100 Series range of passive infrared

More information

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual GG-VL-R REFRIGERANT VENT LINE SENSOR Installation and Operation Manual 2 GG-VL-R Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified

More information