1 K GENERAL INFORMATION Wiegmann has always recognized that our customers in the electrical and electronic marketplace need reliable, high quality enclosures and environmental control products to meet their protection requirements. Protection Requirements today not only mandate NEMA TYPE, R,, & X, but also require a broad mix of BTU & size selections. Wiegmann is proud to offer those choices via a whole new line of A/C products. They are: Advantage Series, Trim Line Series, Micro-Mini Series, Integrity Series, and the Top Mount Series. Three Basic Cooling Methods When selecting a cooling method there are three types to consider. Passive Ventilation If there is only a minimal heat gain in your circumstance, use of louvers or grilles with filters can be effective. This method, however, usually provides less cooling effect than is necessary with today s components. Forced Convection Air Cooling If the installation will be in a clean, non-hazardous environment with an acceptable ambient (outside the enclosure) temperature range, a simple forced-air cooling system utilizing outside air is usually adequate. Combined with an air filter, such devices generally meet the heat removal needs of typical electronic equipment and many electrical applications (Fig. ). Examples of forced convection air cooling are filtered fans, fan trays, and blowers of various types. Closed-Loop Cooling In harsh environments involving high temperatures, wash-down requirements, heavy particulate matter or the presence of chemicals capable of damaging components (NEMA or environments), ambient air must be kept out of the enclosure. Closed-loop cooling consists of two separate circulation systems. One system, sealed against the ambient air, cools and recirculates the clean cool air throughout the enclosure. The second system uses ambient air or water to remove and discharge the heat. Examples of closed-loop cooling equipment employed with electronics and process controls are heat exchangers and air conditioners. FIGURE Forced Convection Method Filter & Grille Required Ambient Air with Heat Load Fan or Blower with filter & grille Ambient Air with Heat Load Ambient Air Fan or Blower with filter & grille Cabinet Ambient Air Filter & Grille Required Cabinet Pressurized System pushes air through enclosure Exhaust System pulls air through enclosure Fans and Blowers can be used to pressurize (preferred) or exhaust cabinet air. The ambient air should be filtered before it enters the cabinet. FIGURE - Closed Loop Cooling Method Heated Air Blower Ambient Air with Heat Load Condenser Heated Air Ambient Air with Heat Load Blowers Ambient Air Cooled Air Ambient Air Heat Exchanger Chilled Air Blower Evaporator In an air-to-air heat exchanger, heat from air surrounding the electronics is removed by a specially designed heat transfer element before being routed back into the enclosure. In air conditioners, a condenser, an evaporator, and two blowers combine to chill the air circulating in the enclosure.

2 AIR CONDITIONERS-APPLICATION INFORMATION K Cooling Control Cabinets Most electrical & electronic control systems generate a substantial amount of heat during operation. This heat factor is intensified as controls are made more compact, perform more functions, and are placed in more confined areas. Additional problems are encountered when the electronic process control system is located on-site in an industrial setting, rather than in a clean computer room. The factory environment can be hostile to the point that performance and effective life of the electronic components are materially reduced, or the control system fails completely. Ambient temperature might be excessively high, as that found in a steel mill. Moisture-laden air and air-borne particulate matter might be present to adversely affect the electronic components, as in the paper manufacturing industry. Air conditioners are designed to perform reliably under many of these harsh conditions and to provide the cooling and environmental protection required by sensitive electronic production control systems. Factors Affecting Model Selection This selection is presented as a basic outline or checklist of the various conditions to be considered when choosing a cooling unit for a certain application. The following are factors which must be considered when selecting a cooling unit: Internal Heat Load This is the heat dissipated by the electronic controls. It is expressed in watts. One watt equals. BTU/HR. Thus, to obtain the approximate cooling capacity required to remove a specific heat load, the following formula can be used: Watts x. = BTU/HR For example, a heat load of 800 watts requires an air conditioner capable of removing at least,70 BTU/HR. Resistance to Air Flow in the Enclosure Air Flow is measured in cubic feet per minute (CFM). To create an air flow of any desired velocity requires that pressure be produced by the blower in the air conditioner. Resistance to this blower-produced air flow is created by obstruction within the cabinet in the air flow path. The resistance itself is called pressure drop (P.D.) and is measured in inches of water column. The effect of significant restrictions in the cabinet air flow path are as follows: The obstructions cause pressure drops, which leads to cool air flow reduction. This reduction in cool air flow will decrease the effective capacity of the cooling unit. When selecting the proper cooling unit, allow-ance must be made for pressure drop. Heat Load From The Surroundings Ambient conditions can cause a heat gain in the enclosure. The rated capacity of the cooling unit must be sufficient to handle this heat gain. When evaluating the additional heat load gained from the surroundings, the subject more or less breaks down into two situations: () the cabinet is insulated and well sealed, or () the cabinet is not insulated (most cabinets are uninsulated.) () Cabinet Insulated Normally, well insulated cabinets will not gain sufficient ambient heat to affect air conditioner s operation. Maximum operating temperature for our air conditioners is 5 F. When the air conditioner operaties in ambient temperatures below 5 F, the cooling capacity of the air conditioner substantially increases. () Cabinet Not Insulated Obviously, this design placed more of a burden on the cooling unit. Heat is conducted to the cool side. Thus, high ambient heat will be readily transmitted into the cooler enclosure. To determine the additional capacity required of our air conditioner installed in an uninsulated cabinet, the surface square footage of the enclosure must be Cooling And Control Cabinets STEP ONE Watt =. BTU/HR. Determine the internal heat load in Watts that must be dissipated. STEP TWO m = 0.76 ft. Calculate the exposed surface area of the enclosure: (h x w ) + (h x d ) + (w x d ) = Area (ft) calculated to obtain the total effective heat transfer area. For this calculation, use the surface area of the sides, plus the area of the top, and omit the bottom area of the cabinet. Air movement outside the uninsulated cabinet will increase the heat conducted from the ambient into the enclosure. When there is little or no air circulation outside the cabinet, the layer of air immediately adjacent to the exterior cabinet walls acts as an insulating film. Exterior air movement dissipates this insulating layer of air in proportion to the velocity of the air flow. Substantial am-bient air circulation will increase the transmitted heat load imposed on the cooling unit. If the cabinet being cooled is not air tight, then high ambient relative humidity will adversely affect the cooling effectiveness of the air conditioner. When humid air infiltrates a poorly sealed enclosure, the air conditioner is required to use up valuable BTU/HR capacity just to condense the moisture from the internal air. Conversely, if the cabinet is well sealed, high ambient relative humidity, has very little effect on the heat capacity of the air conditioner. Steps For Sizing an Air Conditioner Proper selection of an air conditioner is determined by the following criteria: Required cooling capacity BTU/hr. (complete Steps #-) Mounting requirements (top or side mounting options) Dimension of air conditioner and enclosure STEP THREE oc or ok T=.8oF T Determine the temperature differential by subtracting the maximum allowable temperature inside the enclosure (Ti) from the maximum ambient temperature outside the enclosure (To) To-Ti= T STEP FOUR (Watts x.) + [.5 x Area ft. x T ( F)] =BTU/HR. Capacity Required BTU/HR. Capacity Rating

3 K M/TAB MOUNTING TEMPLATE AND ASSEMBLY Description A highlight of the Panel-Mounted TrimLine Series is an easy, revolutionary system for installing Panel-Mounted Air Conditioners and Heat Exchangers onto electronic or electrical enclosures. The M/TAB is standard on all TrimLine Air Conditioners. This integral system functions as a mounting template, preinstallation hanger and final assembly bracket. The M/TAB was specifically designed to assist in the difficult job of installing enclosure Air Conditioners. It simplifies the installation process by eliminating the problem of handling flange-mounted Air Conditioners. The solution is provided by following these installation steps... Use the M/TAB as a template to drill holes for mounting to the enclosure Bolt M/TAB to enclosure Cut out the Supply and Return openings Hang the Air Conditioner or Heat Exchanger on the M/TAB Secure the unit to the M/TAB The M/TAB also allows for the quick removal and transportation of the Air Conditioner or Heat Exchanger, separate from the equipment, for servicing or change to a different capacity samesize Air Conditioner or to a same-size Heat Exchanger. Features No exposed rails or mounting flanges; aesthetically pleasing while conserving cabinet space Reduction in installation time and labor, with significant cost savings Ease of installation and one piece design reduce mounting errors Allows the installer to operate independently Functions as a pre-installation hanger and final assembly bracket Installation is totally outside the enclosure; no clumsy mounting from inside the enclosure

4 INDOOR/OUTDOOR SIDE-MOUNTED AIR CONDITIONERS K5 NEMA TYPE R & MAINTAINED Description At last - air conditioners designed specifically for cooling electronic enclosures that can be used for both indoor and outdoor applications right out of the box! No more bulky unattractive weatherhoods... No more worries over what options to specify for outdoor applications. Expertly designed and crafted, the ADVANTAGE Series boasts a stylish appearance with rounded edges, no visible hardware and a textured baked powder finish to blend easily with contemporary enclosure designs. Serviceability has been made easier by incorporating a knock-down sheetmetal design which provides quick access to internal components. These air conditioners are available in capcities from,000 to,000 BTU/H in seven heights, all utilizing the exclusive M/TAB integral mounting system. Features Capacities:,000 to,000 BTU/H Textured Beige Powder Finish Built-in Condensate Evaporator CFC-Free Refrigerant Closed-Loop Cooling Crankcase Compressor Heater Digital Temperature Display EMI/RFI Suppressor Head Pressure Control Switch Heavy-duty Steel Enclosure Low Temperature Control Thermostat M/TAB Mounting System NEMA R and Ratings Maintained (UL50) Filters Six Foot [.8m] (minimum) SJT -wire Cord UL/CUL Recognized Complete line of accessories RP7,000 BTU/H 7"H x "W x "D RP8,000 BTU/H 8"H x "W x "D RP,000 BTU/H "H x "W x "D RP6 6,000 BTU/H 6"H x 5"W x "D RP7 8,000 &,000 BTU/H 7"H x 5"W x "D RP5 8,000 BTU/H 5"H x 7"W x 6"D RP55,000 BTU/H 55"H x "W x 7"D

5 K6 ADVANTAGE RP7 SERIES AIR-COOLED SIDE-MOUNTED AIR CONDITIONERS.5 [.7] 7.50 [.5] 7. [5.] NEMA TYPE R & MAINTAINED FILTERED CONDENSER AIR INLET (Ambient Air In) CONDENSER OUTLET (Warm Ambient Air Out) WARM AIR RETURN FROM ENCLOSURE COOL AIR OUTLET TO ENCLOSURE 0.9 [77.8] Standard Features Condensate Evaporator CFC-Free Refrigerant Crankcase Compressor Heater Digital Temperature Display EMI/RFI Suppressor Head Pressure Control Switch Filters Low Temperature Control Thermostat M/TAB Mounting System NEMA R & Rating Maintained UL/CUL Recognized Textured Beige Powder Finish Accessories and Options Cooling Effect Detector Enclosure Heater Filter Recoating Adhesive Filters for replacement Internal corrosion protection Painted Metal Grille Power Loss Delayed Compressor Start Short Cycle Protector Special paint finishes Cooling Capacity (BTU/H) PERFORMANCE CHART KACRP7R WACRP7R Maximum enclosure air temperature ºF Ambient Temperature (ºF) Operation within shaded area not recommended. ADVANTAGE SERIES RP7 ADVANTAGE AIR-COOLED PANEL-MOUNTED AIR CONDITIONERS MODEL RATED CAPACITY 95/95 RATING AMBIENT TEMP. F VOLTS HZ RUNNING APPROX. (BTU/H) (BTU/H) MAX./MIN. AMPS WEIGHT (LBS.) WACRP7R /50 5/00 60/50 7.0/7.5 6 WACRP7R /50 0/00 60/ NEW PRODUCT IN 00 (6).8 [7.0] DIA. HOLES.05 [6.7] 0.5 [60.].0 [55.9].06 [5.].00 [5.].06 [7.0] MOUNTING PLAN 9. [6.5] (6).8 [7.0] DIA. HOLES 6.75 [7.5] 6.75 [7.5] 7.00 [77.8] 0.50 [.7] 6.5 [58.8] 7.50 [.5] 9.5 [.] 7.60 [9.0] 6.75 [7.5] 5. [8.] 6.75 [7.5] 7.00 [77.8] 6.5 [58.8] 9. [6.5].5 [8.9] 0.9 [77.9].56 [9.6].5 [.7].00 [5.] DIA. HOLE 6.8 [57.0] 0.56 [.] 0.5 [60.].5 [85.8] 0. [.] Dimensions, inches [metric], are for reference only and subject to change. UL/CUL Recognized models are available as Listed at added cost.. [56.]

6 ADVANTAGE RP8 SERIES AIR-COOLED SIDE-MOUNTED AIR CONDITIONERS K7.5 [.7] 7.75 [70.9] 7.9 [695.6] FILTERED CONDENSER AIR INLET (Ambient Air In) CONDENSER OUTLET (Warm Ambient Air Out) WARM AIR RETURN FROM ENCLOSURE NEMA TYPE R & MAINTAINED COOL AIR OUTLET TO ENCLOSURE 0.9 [77.8] Standard Features Condensate Evaporator CFC-Free Refrigerant Crankcase Compressor Heater Digital Temperature Display EMI/RFI Suppressor Head Pressure Control Switch Filters Low Temperature Control Thermostat M/TAB Mounting System NEMA R & Rating Maintained UL/CUL Recognized Textured Beige Powder Finish Accessories and Options Cooling Effect Detector Enclosure Heater Filter Recoating Adhesive Filters for replacement Internal corrosion protection Painted Metal Grille Power Loss Delayed Compressor Start Short Cycle Protector Special paint finishes Cooling Capacity (BTU/H) PERFORMANCE CHART KACRP8R WACRP8R Maximum enclosure air temperature ºF Ambient Temperature (ºF) Operation within shaded area not recommended. ADVANTAGE SERIES RP7 ADVANTAGE AIR-COOLED PANEL-MOUNTED AIR CONDITIONERS MODEL RATED CAPACITY 95/95 RATING AMBIENT TEMP. F VOLTS HZ RUNNING APPROX. (BTU/H) (BTU/H) MAX./MIN. AMPS WEIGHT (LBS.) WACRP8R /50 5/00 60/50 9.8/ WACRP8R /50 0/00 60/50 5.5/ NEW PRODUCT IN 00.9 [8.5] 9.00 [8.6].67 [.].68 [.7] MOUNTING PLAN 9.00 [8.6] (8).8 [7.0] DIA. HOLES 8.00 [0.] 6.50 [65.] 0.7 [58.] 8.00 [0.] 6.50 [65.].88 [7.] 7.75 [70.8] 8.6 [9.] 7.75 [70.9].88 [7.] 5.00 [7.0] 8.59 [7.9].8 [6.7] 5.00 [7.0].8 [9.9] 0.00 [5.0].78 [5.] 0.9 [77.8].50 [8.].5 [.6] 6. [57.7].00 [5.] DIA. HOLE.8 [0.0] 0.00 [5.0].5 [.7].78 [5.].5 [6.7] UNIT MUST BE [00mm] MINIMUM ABOVE FLOOR FOR FILTER ACCESS Dimensions, inches [metric], are for reference only and subject to change. UL/CUL Recognized models are available as Listed at added cost.

7 K8 ADVANTAGE RP SERIES AIR-COOLED SIDE MOUNT AIR CONDITIONERS.5 [.7].75 [8.9].9 [8.7] FILTERED CONDENSER AIR INLET (Ambient Air In) NEMA TYPE R & MAINTAINED CONDENSER OUTLET (Warm Ambient Air Out) WARM AIR RETURN FROM ENCLOSURE COOL AIR OUTLET TO ENCLOSURE 0.9 [77.8] Standard Features Built-in Condensate Evaporator CFC-Free Refrigerant Crankcase Compressor Heater Digital Temperature Display EMI/RFI Suppressor Head Pressure Control Switch Filters Low Temperature Control Thermostat M/TAB Mounting System NEMA R & Rating Maintained UL/CUL Recognized Textured Beige Powder Finish Accessories and Options Cooling Effect Detector Enclosure Heater Filter Recoating Adhesive Filters for replacement Internal corrosion protection Painted Metal Grille Power Loss Delayed Compressor Start Short Cycle Protector Special paint finishes Cooling Capacity (BTU/H) PERFORMANCE CHART KACRPR WACRPR Maximum enclosure air temperature ºF Ambient Temperature (ºF) Operation within shaded area not recommended. WDTS SERIES 500 BTU SIDE MOUNT AIR CONDITIONERS MODEL RATED CAPACITY 95/95 RATING AMBIENT TEMP. F VOLTS HZ RUNNING APPROX. (BTU/H) (BTU/H) MAX./MIN. AMPS WEIGHT (LBS.) WACRPR /50 5/00 60/50.6/. 98 WACRPR /50 0/00 60/ NEW PRODUCT IN 00.0 [5.8] 0.5 [60.].05 [6.7].7 [69.].0 [5.8] MOUNTING PLAN 0.5 [60.].05 [6.7].7 [69.] 9.6 [.].00 [0.6].5 [9.] 9.6 [.].00 [0.6] (8).8 [7.0] DIA. HOLES 6.50 [9.].75 [8.9] 8.5 [6.9] (8).8 [7.0] DIA. HOLES 6.50 [9.].8 [6.7] 7.75 [96.9] 0.50 [66.7].8 [6.7] 7.75 [96.9].8 [0.0] 9.00 [8.6] 0.00 [5.0].68 [.7].78 [5.] 0.9 [77.9].56 [9.6].5 [.7] 6.8 [57.0].8 [0.0] 9.00 [8.6] 0.00 [5.0].68 [.7].78 [5.].00 [5.] DIA.HOLE. [6.7] UNIT MUST BE [00mm] MINIMUM ABOVE FLOOR FOR FILTER ACCESS Dimensions, inches [metric], are for reference only and subject to change. UL/CUL Recognized models are available as Listed at added cost.

8 ADVANTAGE RP6 SERIES AIR-COOLED SIDE-MOUNTED AIR CONDITIONERS K9 5.5 [89.9] 6.75 [955.5] 6.0 [9.0] FILTERED CONDENSER AIR INLET (Ambient Air In) CONDENSER OUTLET (Warm Ambient Air Out) WARM AIR RETURN FROM ENCLOSURE NEMA TYPE R & MAINTAINED COOL AIR OUTLET TO ENCLOSURE 0.9 [77.8] Standard Features Built-in Condensate Evaporator CFC-Free Refrigerant Crankcase Compressor Heater Digital Temperature Display EMI/RFI Suppressor Head Pressure Control Switch Filters Low Temperature Control Thermostat M/TAB Mounting System NEMA R & Rating Maintained UL/CUL Recognized Textured Beige Powder Finish Accessories and Options Cooling Effect Detector Enclosure Heater Filter Recoating Adhesive Filters for replacement Internal corrosion protection Painted Metal Grille Power Loss Delayed Compressor Start Short Cycle Protector Special paint finishes Cooling Capacity (BTU/H) PERFORMANCE CHART KAC6RP6R WAC6RP6R Maximum enclosure air temperature ºF Ambient Temperature (ºF) Operation within shaded area not recommended. ADVANTAGE SERIES RP6 ADVANTAGE AIR-COOLED PANEL-MOUNTED AIR CONDITIONERS MODEL RATED CAPACITY 95/95 RATING AMBIENT TEMP. F VOLTS HZ RUNNING APPROX. (BTU/H) (BTU/H) MAX./MIN. AMPS WEIGHT (LBS.) WAC6RP6R /50 5/00 60/50 9.5/0.0 WAC6RP6R /50 0/00 60/50 9.5/0.0 6 NEW PRODUCT IN 00 MOUNTING PLAN.0 [7.9].6 [.].0 [7.9].6 [.].88 [.0].88 [.0] ().8 [7.0] DIA. HOLES 6.75 [7.5] 5.75 [6.] 7.75 [96.9] 8.96 [75.6] 6.75 [9.5] 6.0 [9.0] ().8 [7.0] DIA. HOLES 6.75 [7.5] 5.75 [6.] 7.75 [96.9] 8.96 [75.6]. [6.].8 [6.7].50 [7.5].8 [6.7].5 [6.6].56 [9.6] 5. [89.6]. [6.].8 [6.7].50 [7.5].8 [6.7] UNIT MUST BE [00mm] MINIMUM ABOVE FLOOR FOR FILTER ACCESS Dimensions, inches [metric], are for reference only and subject to change. UL/CUL Recognized models are available as Listed at added cost.

9 K0 ADVANTAGE RP7 SERIES AIR-COOLED SIDE-MOUNTED AIR CONDITIONERS NEMA TYPE R & MAINTAINED Standard Features Built-in Condensate Evaporator CFC-Free Refrigerant Crankcase Compressor Heater Digital Temperature Display EMI/RFI Suppressor Head Pressure Control Switch Filters Low Temperature Control Thermostat M/TAB Mounting System NEMA R & Rating Maintained UL/CUL Recognized Textured Beige Powder Finish FILTERED CONDENSER AIR INLET (Ambient Air In) CONDENSER OUTLET (Warm Ambient Air Out) WARM AIR RETURN FROM ENCLOSURE COOL AIR OUTLET TO ENCLOSURE 6.75 [955.5] 5.5 [89.9] 0.9 [77.8] 6.0 [9.0] Accessories and Options Cooling Effect Detector Enclosure Heater Filter Recoating Adhesive Filters for replacement Internal corrosion protection Painted Metal Grille Power Loss Delayed Compressor Start Short Cycle Protector Special paint finishes Cooling Capacity (BTU/H) Cooling Capacity (BTU/H) KAC8RP7R WAC8RP7R Maximum enclosure air temperature ºF Ambient Temperature (ºF) PERFORMANCE CHART KACRP7R WACRP7R Maximum enclosure air temperature ºF Ambient Temperature (ºF) Operation within shaded area not recommended. ADVANTAGE SERIES RP7 ADVANTAGE AIR-COOLED PANEL-MOUNTED AIR CONDITIONERS MODEL RATED CAPACITY 95/95 RATING AMBIENT TEMP. F VOLTS HZ RUNNING APPROX. (BTU/H) (BTU/H) MAX./MIN. AMPS WEIGHT (LBS.) WAC8RP7R /50 5/00 60/50./.7 50 WAC8RP7R /50 0/00 60/50 5.7/ WACRP7R /50 5/00 60/50 9.8/9. 50 WACRP7R /50 0/00 60/50 9./ NEW PRODUCT IN 00. [6.] 5.5 [89.9].50 [7.5]. [6.].50 [7.5] 7.00 [77.8] 7.00 [77.8] ().8 [7.0] DIA. HOLES 7.75 [70.9] 7.5 [00.] ().8 [7.0] DIA. HOLES 7.75 [70.9] 7.5 [00.] 6.8 [89.0] 7.00 [77.8] 7.75 [96.9] 7.00 [77.8] 7.75 [96.9]. [79.5].0 [7.9].50 [7.5].6 [.].8 [6.7]. [79.5].0 [7.9].50 [7.5].6 [.] Dimensions, inches [metric], are for reference only and subject to change..8 [6.7].5 [6.6] UNIT MUST BE [00mm] MINIMUM ABOVE FLOOR FOR FILTER ACCESS 5.5 [89.9] UL/CUL Recognized models are available as Listed at added cost.

10 TRIMLINE SERIES AIR-COOLED SIDE-MOUNTED AIR CONDITIONERS K NEMA TYPE MAINTAINED Description Innovations in technology have resulted in much denser components packaging and smaller available panel sizes on which to mount Air Conditioners. The TrimLine Series is the response to these new packaging demands with the Narrow 0", ", 5" and 7" width panel-mount air conditioners. In addition to being narrower than traditional Air Conditioner units, the TrimLine Series include the Condensate Evaporator, Low Temperature Control Thermostat and EMI/RFI Suppressor as standard features and are available in all popular voltages and frequencies. The TrimLine Series consists of compact models in,000-,500 BTU/H capacities, mid-size models, 8", " and 6" WITH up to,000, 5,000 and 6,000 BTU/H respectively and the fullsize model at 7" with 0,000 BTU/H. Each model series is designed with a minimum width to take up less cabinet space on the exterior panel or door. Integral to the TrimLine Series is the M/TAB (Mounting Template and Assembly Bracket) system which makes installing Air Conditioners simple and fast and interchangeable with corresponding TrimLine Heat Exchangers. Outdoor or corrosive environments require weather protection and/or special internal and external protective features. For outdoor applications see the Advantage and Integrity Outdoor Series. For extreme ambient temperatures and/or severely contaminated environments, the use of TrimLine or other Water-Cooled Air Conditioners are recommended. Features Capacities:,000 to 0,000 BTU/H; six heights available CFC-free or Low ODP Refrigerant All models UL/CUL Listed or Recognized Tested and approved by UL for NEMA Enclosures Compact design with slim 0", ", 5" and 7" wide mounting footprints Exclusive KOOLTRONIC M/TAB integral mounting system for quick, easy installation Built-in Condensate Evaporator eliminates need for draining normal condensate Thermostatic Low Temperature Control prevents over-cooling and provides energy-efficient operation EMI/RFI Suppressor minimizes transient line spikes during on/off cycling Field-reversible condenser outlet blower provides choice of horizontal or vertical air discharge Heavy-duty steel enclosures with gray baked powder finish Six foot (minimum) SJT -wire power cord Complete line of accessories NP7,000 BTU/H 7 H x W x 9 D Narrow-Mini,500 BTU/H 0 H x 0 W x 0 D NP8,000 BTU/H 8 H x W x D NP,000 BTU/H H x W x 9 D NP6,000 & 6,000 BTU/H 6 H x 5 W x D NP7 7,000, 8,000, 0,000,000 BTU/H 7 H x 5 W x D

11 K TRIMLINE NP7 SERIES SIDE-MOUNTED AIR CONDITIONERS THERMOSTAT ADJUSTMENT ACCESS. [08.] M/TAB FILTERED CONDENSER AIR INLET (Ambient Air In) CONDENSER OUTLET (Warm Ambient Air Out) WARM AIR RETURN FROM ENCLOSURE COOL AIR OUTLET TO ENCLOSURE 9.00 [8.6] 7.50 [.5] Standard Features Built-in Condensate Evaporator CFC-Free Refrigerant EMI/RFI Suppressor Low Temperature Control Thermostat M/TAB Mounting System NEMA Rating Maintained (UL50) UL/CUL Listed Gray Powder Finish Accessories and Options Cooling Effect Detector NEMA TYPE MAINTAINED Filter Recoating Adhesive Filters for replacement Internal corrosion protection Lifting Eyes Low Ambient Kit Short Cycle Protector Special materials or finishes Special motors, line cords, or connectors Stainless or Aluminum Cabinet Weather Protection Kit.5 [.] Cooling Capacity (BTU/H) PERFORMANCE CHART KAC.0NP7L WAC.0NP7L Maximum enclosure air temperature ºF Ambient Temperature (ºF) Operation within shaded area not recommended. TRIMLINE SERIES NP7 AIR-COOLED PANEL-MOUNTED AIR CONDITIONERS MODEL RATED CAPACITY 95/95 RATING AMBIENT TEMP. F VOLTS HZ RUNNING APPROX. (BTU/H) (BTU/H) MAX./MIN. AMPS WEIGHT (LBS.) WAC0NP7L /50 5/00 60/50 6.7/ WAC0NP7L /50 0/00 60/ NEW PRODUCT IN 00 MOUNTING PLAN (6) / -0 WELD NUTS M/TAB 9.00 [8.6] FILTER 0.50 [.7] 0.50 [.7].5 [.].5 [85.8] 6. [55.7]. [79.5] 0.8 [9.5] 6' [.8M] MIN. POWER CORD 7.50 [.5] 8. [06.5] 5.00 [7.0]. [0.9] 7.50 [.5] 6.8 [6.] 0.8 [9.5] O.D. CONDENSATE DRAIN. [08.] 0.8 [9.5] (8). [7.9] DIA HOLES [6.] [.] [9.5] Dimensions, inches [metric], are for reference only and subject to change. Weld-nut mounting method, without M/TAB Weld nuts supplied for alternate mounting method to maintain NEMA. Mounting Plans furnished on request.

12 TRIMLINE NP8 SERIES AIR-COOLED SIDE-MOUNTED AIR CONDITIONERS K 0. [57.] M/TAB THERMOSTAT ADJUSTMENT ACCESS FILTERED CONDENSER AIR INLET (Ambient Air In) CONDENSER OUTLET (Warm Ambient Air Out) WARM AIR RETURN FROM ENCLOSURE COOL AIR OUTLET TO ENCLOSURE 8.50 [7.9] NEMA TYPE MAINTAINED.50 [9.] Standard Features Built-in Condensate Evaporator CFC-Free Refrigerant EMI/RFI Suppressor Low Temperature Control Thermostat M/TAB Mounting System NEMA Rating Maintained (UL50) UL/CUL Listed Gray Powder Finish Accessories and Options Cooling Effect Detector Filter Recoating Adhesive Filters for replacement Internal corrosion protection Lifting Eyes Low Ambient Kit Short Cycle Protector Special materials or finishes Special motors, line cords, or connectors Stainless or Aluminum Cabinet Weather Protection Kit KACNP8L WACNP8L Maximum enclosure air temperature ºF Ambient Temperature (ºF) Operation within shaded area not recommended. Cooling Capacity (BTU/H) PERFORMANCE CHART TRIMLINE SERIES NP8 AIR-COOLED PANEL-MOUNTED AIR CONDITIONERS MODEL RATED CAPACITY 95/95 RATING AMBIENT TEMP. F VOLTS HZ RUNNING APPROX. (BTU/H) (BTU/H) MAX./MIN. AMPS WEIGHT (LBS.) WACNP8L /50 5/00 60/50.0/.0 85 WACNP8L /50 0/00 60/ NEW PRODUCT IN 00 MOUNTING PLAN 6' [.8M] MIN. POWER CORD M/TAB.50 [9.] CONDENSATE DRAIN IN BOTTOM. [8.9] 7.00 [77.8].57 [9.8] 0.6 [6.] FILTER 7.75 [96.8].9 [60.7] 8.50 [7.9].9 [06.]. [86.6].76 [70.] 7.75 [96.8].0 [09.].9 [7.] 7.50 [90.5] (8). [7.9] DIA. HOLES.6 [9.6] 0. [57.].50 [8.] 7.00 [77.8] 8.00 [0.].07 [7.] Dimensions, inches [metric], are for reference only and subject to change.

13 K TRIMLINE NP SERIES AIR-COOLED SIDE-MOUNTED AIR CONDITIONERS.50 [7.5] M/TAB FILTERED CONDENSER AIR INLET (Ambient Air In) CONDENSER OUTLET (Warm Ambient Air Out) WARM AIR RETURN FROM ENCLOSURE COOL AIR OUTLET TO ENCLOSURE.88 [85.] THERMOSTAT ADJUSTMENT ACCESS NEMA TYPE MAINTAINED 9.50 [.] Standard Features Built-in Condensate Evaporator CFC-Free or Low ODP Refrigerant EMI/RFI Suppressor Low Temperature Control Thermostat M/TAB Mounting System NEMA Rating Maintained (UL50) Reversible Condenser Outlet Blower UL/CUL Listed Gray Powder Finish Accessories and Options Cooling Effect Detector Enclosure Heater Filter Recoating Adhesive Filters for replacement Internal corrosion protection Lifting Eyes Low Airflow Detector Low Ambient Kit Short Cycle Protector Special materials or finishes Special motors, line cords, or connectors Stainless or Aluminum Cabinet Weather Protection Kit KACNPL WACNPL Maximum enclosure air temperature ºF Ambient Temperature (ºF) Operation within shaded area not recommended. Cooling Capacity (BTU/H) PERFORMANCE CHART TRIMLINE SERIES NP AIR-COOLED PANEL-MOUNTED AIR CONDITIONERS MODEL RATED CAPACITY 95/95 RATING AMBIENT TEMP. F VOLTS HZ RUNNING APPROX. (BTU/H) (BTU/H) MAX./MIN. AMPS WEIGHT (LBS.) WACNPL /50 5/00 60/ WACNPL /50 0/00 60/ NEW PRODUCT IN 00 MOUNTING PLAN.0 [5.8] 0.5 [60.].05 [6.7].7 [69.].0 [5.8] 0.5 [60.].05 [6.7].7 [69.] 9.6 [.].00 [0.6].5 [9.] 9.6 [.].00 [0.6] (8).8 [7.0] DIA. HOLES 6.50 [9.].75 [8.9] 8.5 [6.9] (8).8 [7.0] DIA. HOLES 6.50 [9.].8 [6.7] 7.75 [96.9] 0.50 [66.7].8 [6.7] 7.75 [96.9].8 [0.0] 9.00 [8.6] 0.00 [5.0].68 [.7].78 [5.] 0.9 [77.9].56 [9.6].5 [.7] 6.8 [57.0].8 [0.0] 9.00 [8.6] 0.00 [5.0].68 [.7].78 [5.].00 [5.] DIA.HOLE. [6.7] Dimensions, inches [metric], are for reference only and subject to change.

14 TRIMLINE NP6 SERIES AIR-COOLED SIDE-MOUNTED AIR CONDITIONERS K5 5.9 [85.8] NEMA TYPE MAINTAINED Standard Features Built-in Condensate Evaporator CFC-Free Refrigerant EMI/RFI Suppressor Low Temperature Control Thermostat M/TAB Mounting System NEMA Rating Maintained(UL50) Reversible Condenser Outlet Blower UL/CUL Listed/Recognized Gray Powder Finish Accessories and Options Cooling Effect Detector FILTERED CONDENSER AIR INLET (Ambient Air In) CONDENSER OUTLET (Warm Ambient Air Out) WARM AIR RETURN FROM ENCLOSURE COOL AIR OUTLET TO ENCLOSURE Filter Recoating Adhesive Filters for replacement Internal corrosion protection Lifting Eyes Low Ambient Kit Low Airflow Detector Short Cycle Protector Special materials or finishes Special motors, line cords, or connectors Stainless or Aluminum Cabinet Weather Protection Kit 6.75 [9.5].5 [.] Cooling Capacity (BTU/H) Cooling Capacity (BTU/H) KACNP6L WACNP6L Maximum enclosure air temperature ºF Ambient Temperature (ºF) PERFORMANCE CHARTS KAC6NP6R WAC6NP6R Maximum enclosure air temperature ºF Ambient Temperature (ºF) Operation within shaded areas not recommended. TRIMLINE SERIES NP6 AIR-COOLED PANEL-MOUNTED AIR CONDITIONERS MODEL RATED CAPACITY 95/95 RATING AMBIENT TEMP. F VOLTS HZ RUNNING APPROX. (BTU/H) (BTU/H) MAX./MIN. AMPS WEIGHT (LBS.) WACNP6L /50 5/00 60/ WACNP6L /50 0/00 60/ WAC6NP6R /50 5/00 60/50 6.5/7.0 5 WAC6NP6L /50 0/00 60/ NEW PRODUCT IN 00 (OPTIONAL) MOUNTING PLAN 6' [.8M] MIN. POWER CORD M/TAB.5 [.].50 [8.] 5.06 [8.6].00 [0.8] THERMOSTAT.00 [0.8] 6.75 [9.5] (0). [7.9] DIA. HOLES 6.75 [7.5] 9.8 [9.] 6.75 [9.5] 8.5 [09.6] CONDENSATE DRAIN FILTER 5.9 [85.8].5 [.8] 0.88 [.].50 [7.5]. [8.].00 [76.] 0.75 [9.] Dimensions, inches (metric), are for reference only and subject to change. UL/CUL Recognized models are available as Listed at added cost.

15 K6 TRIMLINE NP7 SERIES AIR-COOLED SIDE-MOUNTED AIR CONDITIONERS THERMOSTAT ADJUSTMENT ACCESS 5.9 [85.8] FILTERED CONDENSER AIR INLET (Ambient Air In) CONDENSER OUTLET (Warm Ambient Air Out) WARM AIR RETURN FROM ENCLOSURE COOL AIR OUTLET TO ENCLOSURE NEMA TYPE MAINTAINED M/TAB 7.5 [00.].5 [.] Cooling Capacity (BTU/H) PERFORMANCE CHARTS KAC8NP7R WAC7NP7L Maximum enclosure air temperature ºF Ambient Temperature (ºF) Standard Features Built-in Condensate Evaporator CFC-Free or Low ODP Refrigerant EMI/RFI Suppressor Low Temperature Control Thermostat M/TAB Mounting System NEMA Rating Maintained (UL50) Reversible Condenser Outlet Blower UL/CUL Listed/Recognized Gray Powder Finish Accessories and Options Cooling Effect Detector Deep Drain Pan Kit Enclosure Heater Filter Recoating Adhesive Filters for replacement Internal corrosion protection Lifting Eyes Low Airflow Detector Low Ambient Kit Short Cycle Protector Special materials or finishes Special motors, line cords, or connectors Stainless or Aluminum Cabinet Weather Protection Kit KACNP7R WAC0NP7R Maximum enclosure air temperature ºF Ambient Temperature (ºF) Operation within shaded areas not recommended. Cooling Capacity (BTU/H) TRIMLINE SERIES NP7 AIR-COOLED PANEL-MOUNTED AIR CONDITIONERS MODEL RATED CAPACITY 95/95 RATING AMBIENT TEMP. F VOLTS HZ RUNNING APPROX. (BTU/H) (BTU/H) MAX./MIN. AMPS WEIGHT (LBS.) WAC6NP7L /50 5/00 60/ WAC6NP7L /50 0/00 60/ WAC7NP7L /50 5/00 60/ WAC7NP7L /50 0/00 60/ WAC8NP7L /50 5/00 60/ WAC8NP7L /50 0/00 60/ WAC0NP7R /50 5/00 60/50 9./ WAC0NP7L /50 0/00 60/ WACNP7R /50 5/00 60/50 9./ WACNP7L /50 0/00 60/ NEW PRODUCT IN 00 MOUNTING PLAN (OPTIONAL).5 [.] M/TAB 6' [.8M] MIN. POWER CORD 0.88 [.].50 [8.].8 [76.]. [8.].00 [0.7] 8.00 [57.] FILTER 7.5 [00.] (). [7.9] DIA. HOLES 7.00 [77.8].88 [606.] 6.6 [8.] 0. [57.] 0.75 [9.0] 5.9 [85.8] OPTIONAL CONDENSATE DRAIN CONDENSATE DRAIN.5 [.8].50 [7.5].00 [76.] Dimensions, inches [metric], are for reference only and subject to change. UL/CUL Recognized models are available as Listed at added cost.

16 MICRO-MINI SERIES AIR-COOLED SIDE-MOUNTED AIR CONDITIONERS K7 THERMOSTAT ADJUSTMENT ACCESS.5 [6.6] FILTERED CONDENSER AIR INLET (Ambient Air In) CONDENSER OUTLET (Warm Ambient Air Out) WARM AIR RETURN FROM ENCLOSURE COOL AIR OUTLET TO ENCLOSURE.88 [7.] NEMA TYPE MAINTAINED. [58.9] 6.5 [58.8] Standard Features Ball-bearing Motors CFC-Free Refrigerant EMI/RFI Suppressor Low Temperature Control Thermostat NEMA Rating Maintained (UL50) UL/CUL Listed Gray Powder Finish Accessories and Options Adapter Plate for rack mounting Compressor Heater Condensate Evaporator Cooling Effect Detector Filter Recoating Adhesive Filters for replacement Internal corrosion protection Lifting Eyes Low Ambient Kit and Compressor Heater Mounting Hinge Short Cycle Protector Special materials or finishes Special motors, line cords, or connectors Stainless or Aluminum Cabinet Weather Protection Kit MICRO-MINI SERIES AIR-COOLED PANEL-MOUNTED AIR CONDITIONERS MODEL RATED CAPACITY 95/95 RATING AMBIENT TEMP. F VOLTS HZ RUNNING APPROX. (BTU/H) (BTU/H) MAX./MIN. AMPS WEIGHT (LBS.) WAC0MML /50 5/00 60/50.5 WAC0MML /50 0/00 60/50. WACMML /50 5/00 60/50.5 WACMML /50 0/00 60/50. 6 NEW PRODUCT IN 00 MOUNTING PLAN.75 [69.9].6 [6.]. [.7] ().8 [5.5] DIA. HOLES (). [8.0] DIA. HOLES. [58.8].6 [6.]. [.7] 0.5 [6.] 0.8 [0.6].75 [69.9] 0.8 [0.6] 9.8 [9.].5 [8.6].88 [.8].00 [0.6].00 [0.8].88 [7.].88 [.8].00 [0.6]. [09.5].88 [7.].50 [.]. [.7] DIA..5 [8.6] 7.9 [0.6].50 [8.] 6.6 [58.8] 0.68 [7.] 0.6 [5.9]. [58.8].5 [6.6].50 [8.].50 [8.] DIA. POWER CORD HOLE.50 [.] 8.00 [0.].00 [5.].00 [5.] OPTIONAL POWER CORD EXIT CONDENSATE DRAIN Dimensions, inches [metric], are for reference only and subject to change.

17 K8 INTEGRITY SERIES NEMA/X AIR-COOLED SIDE-MOUNTED AIR CONDITIONERS NEMA TYPE /X MAINTAINED Description Designed specifically for NEMA and X Enclosure applications that require washdown or are subject to outdoor storm conditions, Integrity NEMA /X Air Conditioners protect the ratings of NEMA or X Enclosures. These exclusive patented UL/CUL Recognized Panel-Mounted Air Conditioners provide superior closedloop cooling and also protect against the hazards specified for both Indoor and Outdoor NEMA and X Enclosures. Tested and rated by universally recognized Underwriters Laboratories, these uniquely-designed 0-B Stainless Steel Air Conditioners prevent unwanted environmental penetration of NEMA and X Enclosures as they provide a clean, cool internal environment. With the design advantages of the Integrity NEMA /X Series and the inclusion of the unique Mounting Template and Assembly Bracket (M/TAB), modified for this design, this series offers the finest in cooling innovation and technology. Features Capacities range from,000 to 0,000 BTU/H in ", 8", 7" and 59" heights UL/CUL Listed or Recognized Tested and approved by UL for NEMA and X Enclosures CFC-free Refrigerant Gasketed flanges on all four mounting edges for positive leakproof seal Exclusive modified integral Mounting Template and Assembly Bracket (M/TAB) for quick, easy installation. Thermostatic Low Temperature Control prevents over-cooling and provides energy-efficient operation Internal Corrosion Protection EMI/RFI Suppressor minimizes transient line spikes during on/off cycling Separate blower-driven evaporator and condenser air systems penetrate high static pressure applications Rugged heavy duty stainless steel exterior

18 INTEGRITY SERIES AIR-COOLED SIDE-MOUNTED AIR CONDITIONERS K9. [.] NEMA TYPE /X MAINTAINED FILTERED CONDENSER AIR INLET (Ambient Air In) CONDENSER OUTLET (Warm Ambient Air Out) WARM AIR RETURN FROM ENCLOSURE COOL AIR OUTLET TO ENCLOSURE M/TAB.5 [89.].50 [68.].00 [0.].50 [800.] THERMOSTAT ADJUSTMENT ACCESS Standard Features CFC-Free Refrigerant EMI/RFI Suppressor Internal corrosion protection Low Temperature Control Thermostat M/TAB Mounting System NEMA /X Rating Maintained (UL50) Stainless Steel Cabinet UL/CUL Recognized Accessories and Options Cooling Effect Detector Filter Recoating Adhesive Filters for replacement Lifting Eyes Low Ambient Kit & Compressor Heater Short Cycle Protector Special materials or finishes Cooling Capacity (BTU/H) PERFORMANCE CHART KNACPR WNACPR Maximum enclosure air temperature ºF Ambient Temperature (ºF) Operation within shaded areas not recommended. INTEGRITY SERIES AIR-COOLED PANEL-MOUNTED AIR CONDITIONERS MODEL RATED CAPACITY 95/95 RATING AMBIENT TEMP. F VOLTS HZ RUNNING APPROX. (BTU/H) (BTU/H) MAX./MIN. AMPS WEIGHT (LBS.) WNACPR /50 5/00 60/50.0/.0 05 WNACPR /50 0/00 60/ WNACPR /50 5/00 60/50.0/.0 05 WNACPR /50 0/00 60/ NEW PRODUCT IN 00 MOUNTING PLAN.5 [.7].00 [0.6].5 [07.9] UNIT.50 [68.] ().50 [6.] DIA. HOLES.50 [800.].5 [.7].6 [7.].00 [50.8] M/TAB & CUTOUTS 5. [0.0].00 [0.] 0.50 [66.7] 8.00 [0.] (6). [8.0] DIA. HOLES 8.00 [0.].8 [55.].8 [55.]. [79.].00 [0.6] POWER CORD 6.00 [660.] 5.00 [7.0] 0.9 [766.8].06 [.7].5 [89.].50 [68.]. [.].00 [5.].00 [0.6].5 [08.0].7 [.8] 0.7 [9.].75 [9.] 0.7 [9.] UNIT OUTLINE.50 [88.9].50 [9.].50 [8.].8 [96.8] ().0 [5.0] DIA. HOLES M/TAB OUTLINE.88 [7.] 0.88 [.] 0.8 [0.6] M/TAB.75 [9.] [5.] [9.7] UNIT MUST BE " (00mm) MINIMUM ABOVE FLOOR FOR FILTER ACCESS Dimensions, inches [metric], are for reference only and subject to change. UL/CUL Recognized models are available as Listed at added cost.

19 K0 INTEGRITY 8 & 7 SERIES AIR-COOLED SIDE-MOUNTED AIR CONDITIONERS NEMA TYPE /X MAINTAINED M/TAB A 8.56 [7.] FILTERED CONDENSER AIR INLET (Ambient Air In) CONDENSER OUTLET (Warm Ambient Air Out) 7.06 [.] 8.00 [57.] K THERMOSTAT ADJUSTMENT WARM AIR RETURN FROM ENCLOSURE COOL AIR OUTLET TO ENCLOSURE PERFORMANCE CHARTS KNAC7P R WNAC7P8R Maximum enclosure air temperature ºF Ambient Temperature (ºF) KNAC0P R WNAC0P7R Maximum enclosure air temperature ºF Ambient Temperature (ºF) Operation within shaded areas not recommended. Cooling Capacity (BTU/H) Cooling Capacity (BTU/H) INTEGRITY SERIES 8 & 7 AIR-COOLED PANEL-MOUNTED AIR CONDITIONERS MODEL RATED CAPACITY 95/95 RATING AMBIENT TEMP. F VOLTS HZ RUNNING APPROX. (BTU/H) (BTU/H) MAX./MIN. AMPS WEIGHT (LBS.) WNAC6P8R /50 5/00 60/ WNAC6P8R /50 0/00 60/50 9./ WNAC7P8R /50 5/00 60/ WNAC7P8R /50 0/00 60/50 9./ WNAC8P7R /50 0/00 60/50 0.9/.5 05 WNAC0P7R /50 0/00 60/50 0.9/.5 05 DIMENSIONS INCHES (METRIC) MODEL A B C D E SERIES (958.8) 6.69 (9.9).75 (.8).75 (.8) 8. (6.5) SERIES (9.8) 5.9 (66.6).5 (.).5 (85.7) 7.7 (695.) MODEL F G H J K SERIES 8.50 (6.5). (0.) 6.00 (5.) 7.00 (685.8) 7.00 (99.8) SERIES 7.50 (6.5).00 (0.6) 8.00 (0.).00 (88.) 6.5 (7.7) 6 NEW PRODUCT IN 00 UNIT MOUNTING PLAN M/TAB & CUTOUTS.5 [.7] 8.56 [7.] ( J ).50 [6.] DIA. HOLES.75 [.] (H). [7.9] DIA. HOLES 5.00 [8.] 8.56 [7.]. [.7] 9. [6.5] 8.8 [.8].8 [.5].00 [0.6] C 9.75 [7.6] 7. [88.9] 5 (J).50 DIA. HOLES G B A.87 [7.8].8 [80.7] D.8 [07.8]. [5.] E F B 5.5 [87.] 6.69 [69.9] A K G.50 [8.].50 [8.] 5.8 [.5] 7.75 [50.8] 0.68 [7.] UNIT OUTLINE [50.6] [.] M/TAB OUTLINE 0.69 [7.5].50 [8.] 5.9 [.8] 6.88 [8.6].6 [69.9] 0.8 [0.6] M/TAB 8. [60.].50 [8.] 7.75 [50.9] APPROXIMATE WEIGHT (LBS.) Series 8 80 Series 7 05 UNIT MUST BE " (00mm) MINIMUM ABOVE FLOOR FOR FILTER ACCESS DRAIN 7. [5.0] Dimensions, inches [metric], are for reference only and subject to change. UL/CUL Recognized models are available as Listed at added cost.

20 WDTS SERIES 000 BTU NEMA X SIDE-MOUNTED AIR CONDITIONER K0A WDTS0005NX Industry Standards UR, cur, and CE recognized NEMA,, X Applications Designed for side mounting on any enclosure surface where hot spot cooling or low capacity cooling is required Meets NEMA,, X protection against water and corrosive material Closed loop cooling ensures clean enclosure air is recirculated without ever mixing the contaminated ambient air Clean stainless steel design Features Ra refrigerant Thermostat control (must remove cover) Expansion valve permits increased efficiency through improved evaporator heat transfer and less frequent compressor operation Built in condensate evaporator Continuous air circulation from high capacity fans EMI/RFI suppression meets CE requirements 8' line cord with plug on 5V versions. 8' line cord with no plug on 0V versions Aluminum filter provided with easy access for cleaning Gasket, mounting kit, and template for enclosure cutout and drilling are included Exterior case easily removable for field service Q Mount allows unit to hang in place for easy installation Accessories Replacement Filters Operation Notes In extremely humid environments, condensation may accumulate and is drained-off through the overflow outlet. A hose may be attached to the mm outlet to drain the water in a controlled manner cooling capacity Q 0 (BTU) (Watt) cabinet air temperature T i WDTS ºC/ºF +5ºC/95ºF ºC/77ºF T u (ºC) (ºF) ambient air temperature

21 K0B WDTS SERIES 000 BTU NEMA X SIDE-MOUNTED AIR CONDITIONER WDTS 000 SERIES NEMA X SIDE MOUNT AIR CONDITIONER CATALOG RATED CAPACITY RATED RANGE OF POWER RUNNING STARTING 8' LINE NUMBER (BTU/H) VOLTAGE WATTS OPERATION CONSUMPTION AMPS CURRENT CORD WDTS0005NX 000 5V 60Hz 0V 50Hz V 70W.9A.8A w/plug WDTS0000NX 000 0V 50/60 Hz V 0W.A 7.A w/out plug EMI/RFI Suppression: According to CE Type of Refrigerant: Ra Refrigerant Charge: 00g Adjustable Thermostat: Factory set at +95º F (+5º C) Max. Ambient Air Temp.: +5º F (+5º C) Min. Ambient Air Temp.: +6º F (+8º C) Air Capacity Circulation: 0 CFM Internal, 0 CFM External (unrestricted) Condensate Discharge: Filter Mat: Db Noise Level: Unit Weight: Exterior Housing: Condensate evaporator 50 g/m 6 db (A) 7 lbs. (.7kg) 0 stainless steel *Special order product. Consult factory for lead time. 0.57" (.5) 5.6" ().6" (86) 8.90" (.6) 8.5" (6.5).87" (7).68" (9) 7.5" (90.5)." (5) 0." Ø 8(6x) 7.5" (5) 9.0" (9.6).6" (95.) 7.5" (90.5) 5.6" (.8).07" (0.) 6.5" (Ø 65.) 5.6" () " (5.)

22 COMPACT SERIES AIR COOLED TOP-MOUNT AIR CONDITIONERS K THERMOSTAT ADJUSTMENT POWER CORD 7.00 [.8] FILTERED CONDENSER AIR INLET (Ambient Air In) CONDENSER OUTLET (Warm Ambient Air Out) WARM AIR RETURN FROM ENCLOSURE 0.5 [60.] COOL AIR OUTLET TO ENCLOSURE FILTER 0.00 [508.0] DRAIN Standard Features Built-in Condensate Evaporator CFC-Free Refrigerant EMI/RFI Suppressor Low Temperature Control Thermostat UL/CUL Listed Gray Powder Finish Accessories and Options Cooling Effect Detector Enclosure Heater Filter Recoating Adhesive Filters for replacement Internal corrosion protection Lifting Eyes Low Airflow Detector Low Ambient Kit Short Cycle Protector Special materials or finishes Special motors, linecords or protectors Stainless or Aluminum Cabinet KACHTL WACHTL Maximum enclosure air temperature ºF Ambient Temperature (ºF) Operation within shaded areas not recommended. Cooling Capacity (BTU/H) PERFORMANCE CHART COMPACT SERIES AIR-COOLED TOP-MOUNTED AIR CONDITIONERS MODEL RATED CAPACITY 95/95 RATING AMBIENT TEMP. F VOLTS HZ RUNNING APPROX. (BTU/H) (BTU/H) MAX./MIN. AMPS WEIGHT (LBS.) WACHTL /50 5/00 60/ WACHTL /50 0/00 60/ WACHTL /50 5/00 60/ WACHTL /50 0/00 60/ NEW PRODUCT IN [6.5] 0.75 [9.] MOUNTING PLAN 7.00 [.8] 5.50 [9.7].50 [.9].75 [.5] 8.00 [0.].6 [0.7].9 [55.6] 0.5 [60.] 0.00 [508.0] 0.50 [66.7] ().5 [6.] WELD NUTS 7.75 [96.9] [6.] [0.6] 0.00 [508.0].75 [.5] 5.00 [7.0].50 [8.] 7.00 [.8].50 [.] POWER CORD 0.50 [.7] POWER CORD 5' [.5] CONDENSATE DRAIN TUBE.50 [.].50 [.].00 [50.8].75 [.5].00 [50.8].50 [.]

23 K VORTEX COOLERS Industry Standards UL Listed NEMA, or X NEMA /X NEMA UL File E576 Applications Compressed air cooling is used where conventional enclosure cooling (air conditioners or heat exchangers) is not possible. Example: Small to medium size enclosures; nonmetallic enclosures; areas where the size of cooling devices is restricted. Features Suitable for harsh environments Small physical size Creates cool air without refrigerants (no CFC s, HFC s) Exceptionally reliable no moving parts Virtually no maintenance Requirements Clean, dry, oil-free compressed air (00 PSIG/70ºF or below) required to achieve published BTU/hr. ratings. Lower pressures and higher temperatures will reduce BTU/hr. ratings A 5 micron water and particulate removal filter must be installed prior to operating any Vortex Cooler (included in kits) An oil removable filter can be installed between the 5 micon filter and the Vortex cooler if oil is present in the compressed air line Mounting holes: NEMA kits () -/" (8mm) or /" knockout hole for cooling tube and () /6" hole for thermostat NEMA & NEMA X kits () -5/6" (9mm) or -/" knockout hole for cooling tube and () #8 holes for thermostat Kit Includes the Following Vortex Cooling Tube Solenoid Valve 0V 60Hz 0V 50 Hz (0V available) 5 micron water and particulate removal filter Ducting Kit Thermostat How Enclosure Coolers Create Cold Air Vortex Coolers are powered by a vortex tube a unique device that creates a vortex from compressed air and separates it into hot and cold airstreams. Here s how it works. The vortex tube s cylindrical generator causes the input compressed air to rotate, reaching speeds up to,000,000 rpm as it is forced down the inner walls of the hot, or longer end of the vortex tube. At the end of the hot tube, as small portion of this air exits through a needle valve as hot air exhaust. The remaining air is forced back through the center of the incoming air stream at a slower speed. The heat in the slower moving air is transferred to the faster moving incoming air. This super-cooled air flows through the center of the generator and exits through the cold air exhaust port. Compressed Air In Control Value Cold Air Out Vortex Generation Chamber Hot Air Out

24 VORTEX COOLERS K VORTEX COOLERS CAPACITY AIR CONSUMPTION TUBE CATALOG THERMOSTAT SURFACE THERMOSTAT NEMA UL COOLING TUBE NUMBER BTUH KCAL/H SCFM SLPM (FACTORY SET) TEMP AT BTU MOUNTING TYPE TYPE MATERIAL W F ± 50 F External Aluminum W F ± 50 F External Aluminum W F ± 50 F External Aluminum W F ± 50 F Internal Aluminum W797SS F ± 50 F Internal X X Stainless Steel ACCESSORIES CATALOG NUMBER W8OILFILTER WOILFILTER FILTER TYPE AND SIZE Auto-drain oil removal filter, /8" NPT (F), rated to 5 SCFM/708 SLPM Auto-drain oil removal filter, /" NPT (F), rated to 50 SCFM/5 SLPM Model W75000 Model W70900 & W Model W & W797SS700 Note: Thermostats for Models W75000, W70900 and W mounts in an /6" (8mm) diameter hole.

25 K WPFB/WPFBE FILTERED BOX FANS & GRILLES Applications Used for enclosure cooling in low static pressure applications. Features High airflow with low noise operation makes these versatile cooling fans very popular in a wide range of applications Reliable cooling is achieved particularly in areas with minimum space requirements The cooling system incorporates the filtered fan boxes as its air inlet, while the exhaust grille is the air outlet The washable aluminum filter grille and air filter is easily accessible and can be removed for cleaning Available in 5 VAC or 0 VAC 50/60 Hz versions Heavy gauge steel construction Attractive, ascetically appealing grille design All models can pressurize or exhaust Aluminum filter is coated with adhesive baffle surfaces for dust and dirt collection. Can be recoated after cleaning for optimum performance Note: One grille and filter are included with each fan package. Normally, an additional exhaust grille and filter required for each installation and must be ordered separately. Accessories Exhaust Grille and Filters (see page L) Filter Coat PERFORMANCE GRAPHS STATIC PRESSURE.0.5 WPFB00 WPFB00 WPFB500 KP0 KP60 Fan: Unit: 60 Hz. 50 Hz. 60 Hz. 50 Hz. STATIC PRESSURE.0.5 Fan: Unit: 60 Hz. 50 Hz. 60 Hz. 50 Hz. STATIC PRESSURE.50.5 KP00 Fan: Unit: 60 Hz. 50 Hz. 60 Hz. 50 Hz AIRFLOW C.F.M AIRFLOW C.F.M AIRFLOW C.F.M. Static pressure is in inches of water.

26 WPFB/WPFBE SERIES FILTERED BOX FANS & GRILLES K5 WPFB Box Fan WPFBE Exhaust Grille with Filter Filter Coat Industry Standards UR, cur, and CE recognized WPFB SERIES BOX FANS CATALOG FREE-FLOW AIR RATED NOMINAL RUNNING WATTS A B C D E F G H NUMBER DELIVERY (CFM) VOLTAGE (RPM) AMPS WPFB WPFB WPFB WPFB WPFB WPFB (56) (88) (6) () (6) (05) (9) (78) (56) (88) (6) () (6) (05) (9) (78) (9) (6) (76) (8) (00) () () (6) (9) (6) (76) (8) (00) () () (6) (95) (0) (6) (8) (0) (75) (5) (8) (95) (0) (6) (8) (0) (75) (5) (8) WPFBE SERIES EXHAUST GRILLES WITH FILTERS CATALOG NUMBER WITH FILTER FILTER ONLY WPFBE00 WPFBE00 WPFBE500 WPFBM00 WPFBM00 WPFBM500 A B D E F G W* (56) (88) () (6) (05) (9) () (9) (6) (8) (00) () () (8) (95) (0) (8) (0) (75) (5) (8) FILTER COAT CATALOG NUMBER DESCRIPTION WAX0 0 oz pump spray bottle C D H E 0.9 DIA PLACES D F F D G A 0.6 D G AIR FLOW E B

27 K6 MUFFIN FANS & FINGER GUARDS WAAXFN WAGARD6 MUFFIN FANS & FINGER GUARDS Applications Designed for use in enclosures where space is limited and reliable cooling is required. Features Fan furnished standard with " lead wire. 90 degree plug attached Black color Impeller and frame are glass reinforced thermoplastic, UL9-VO Die cast aluminum housing Finger guards are welded electroplated nickel chrome steel wire. Guards withstand 00 lbs. separation force to meet UL, CSA standards One finger guard and all mounting hardware is provided. Additional finger guards can be mounted on either side for maximum safety WAXFN SERIES MUFFIN FANS & WAGARD SERIES FINGER GUARDS CATALOG NUMBER RATED RATED VOLTAGE FREQ NOISE MAXIMUM AIR FLOW MAXIMUM DIMENSIONS FAN INPUT SPEED STATIC FAN RATING (Hz) LEVEL H X W X D GUARD (WATTS) (RPM) (M/MIN) CFM PRESSURE/H0 WAAXFN WAGARD 5 7/5 50/60 500/000 7 ±.5/. 88/0 5.8/7.0.7x.7x.50 (0x0x8) WAAXFN WAGARD 0 7/5 50/60 500/000 7 ±.5/. 88/0 5.8/7.0.7x.7x.50 (0x0x8) WA6AXFN WAGARD6 5 6/5 50/60 800/500 6 ± 5./6.6 90/5 5./ x6.77x.0 (7x7x5) WA6AXFN WAGARD6 0 6/5 50/60 800/500 6 ± 5./6.6 90/5 5./ x6.77x.0 (7x7x5) WA0AXFN WAGARD / x0.00x.50 (5x5x89) WA0AXFN WAGARD0 0 50/ x0.00x.50 (5x5x89)

28 WAVK, WAVK-SS & WAFLT LOUVER PLATE KITS & FILTER KITS K7 WAVK00SSA WAFLT LOUVER PLATE KITS Description Designed to provide ventilation or cooling in enclosures where excessive moisture or excessive internal heat is a problem. These kits are fabricated from gauge steel and include all hardware for mounting. Kits are easily field installed by making a cutout of the proper size and attaching the louver plate in place. Finish is ANSI 6 gray polyester powder finish over phosphatized surfaces or 6 stainless steel. Filter kit must be ordered separately. FILTER KITS FOR LOUVER PLATES KITS Description Designed for use with Louver Plate Kit. Mounting holes on filter brackets align with mounting holes on louver kits. Aluminum filters are good for stopping dust and dirt from penetrating the enclosures. Filters are designed to mount behind louver kits. Kit consists of aluminum filter, brackets and all necessary hardware for installation. Louver kit must be ordered separately. WAVK SERIES LOUVER PLATE KIT AND WAFLT SERIES FILTER KITS FOR LOUVER PLATES CATALOG NUMBER NUMBER NUMBER LOUVER KIT LOUVER KIT OF OF LOUVER FILTER KIT PAINTED 6 S.S. LOUVERS ROWS WAVK00 WAVK00SSA6 WAVK00 WAVK00SSA6 WAFLT WAVK00 WAVK00SSA6 WAFLT WAVK00 WAVK00SSA6 WAFLT WAVK060 WAVK060SSA6 WAFLT6 WAVK0606 WAVK0606SSA6 WAFLT66 6 WAVK0806 WAVK0806SSA6 WAFLT86 WAVK0808 WAVK0808SSA6 WAFLT88 6 WAVK08 WAVK08SSA6 WAFLT8 LOUVER LENGTH A B L M P R S (5) (8) (8) (5) (5) (6) (6) (76) (98) () (67) (8) (79) (95) (76) () () (89) (8) (0) (95) (0) () (0) () (08) () () (5) () (9) () (59) () (7) (5) (00) (9) (68) (59) (8) (7) (90) (0) (08) () (76) (0) (89) () (9) (0) (68) () (6) (0) (9) () () (0) (6) () (57) (0) (70) () (85) 6 NEW PRODUCT IN 00 Note: Center holes (dimension S ) are not needed on any filter kits. Only 6 x 6 and larger louver kits require center holes.

29 K8 WAVK, WAVK-SS & WAFLT LOUVER PLATE KITS & FILTER KITS Notes: Installation Instructions. Make sure the proper louver kit and/or filter kit has been ordered.. Locate and mark holes and cutout as shown in figure.. Drill holes using a 7/" drill bit making sure there are no electrical wires or internal components in the way.. Assemble louver kits and/or filter kits as shown in figure. Note: After installation is complete, make sure louver and filter kits do not interfere with any internal or external equipment.

30 EHG SERIES ENCLOSURE RADIANT HEATERS K9 EHG00 Industry Standards UL Recognized Component cul Recognized Component CE Recognized Applications Designed to provide enclosed electronic, pneumatic, hydraulic, and mechanical equipment with protection from low temperatures, condensation, and corrosion. Features Positive Temperature Coefficient heater unit maintains a stable temperature environment within enclosures, allowing critical components to perform with consistent reliability for longer periods Expanded voltage range of 0V to 0V Heating body is extruded, black anodized, aluminum Easily installed by clip mounting on 5mm DIN rails Connection: Push-type terminals Protection Class: (tested for grounding at,600v) CAUTION Do not mount on wooden structures. Avoid placement near heat-sensitive components Accessories Thermostats (see pages K-K) EHG SERIES ENCLOSURE RADIANT HEATERS CATALOG RATED DIMENSIONS WATTS* Hz NUMBER VOLTAGE H X W X D EHG /60.60x.80x.00 (65x70x50) EHG /60.60x.80x.00 (65x70x50) EHG /60.60x.80x.00 (65x70x50) EHG / x.80x.00 (0x70x50) EHG / x.80x.00 (0x70x50) EHG / x.80x.00 (0x70x50) EHG / x.80x.00 (0x70x50) *Due to the nature of PTC heaters, the actual power rating of the heater can be up to 0% lower, or 5% higher than the nominal power rating at 68ºF (0ºC) ambient temperature.

31 K0 WHVL SERIES ENCLOSURE FAN HEATERS WHVLO000 Industry Standards UL Recognized Component cul Recognized Component CE Recognized Applications Used when larger heating capacities or internal forced air circulation is required and space is limited. Features Compact design to prevent condensation or maintain minimum temperature in enclosures Cartridge heater heating element 0,000 hour life expectancy at 68ºF ambient Connection: 5 pole terminal for max. AWG Easily installed by clip mounting on 5mm DIN rails Protection class (tested for grounding at,50 V) Heater comes fully assembled with fan CAUTION Do not mount on wooden structures. Avoid placement near heat-sensitive components. Note that fan must be used in conjunction with heating element Accessories Thermostats (see pages K-K) WHVL SERIES ENCLOSURE FAN HEATERS OPERATING MAXIMUM CATALOG RATED DIMENSIONS WATTS CURRENT TEMPERATURE NUMBER VOLTAGE H X W X D (AMPS) WITH FAN WHVLO ºF (0ºC).85x.5x.(7x80x) WHVLO ºF (60ºC).85x.5x.(7x80X) WHVLO ºF (0ºC).85x.68x5.9(7x9x5) WHVLO ºF (60ºC).85x.68x5.9(7x9x5) WHVLO ºF (80ºC).85x.68x5.9(7x9x5) 00 & 50W Heaters 00, 00 & 00W Heaters

32 WCR SERIES FAN HEATERS K WCR07500 Industry Standards UL Recognized Component cul Recognized Component CE Recognized Applications Designed to protect sensitive mechanical, electrical, and electronic equipment from the harmful effects of condensation, corrosion, and low temperatures. Thermostatically controlled fan-driven heater units maintain a stable temperature with enclosure so critical components can perform more reliably over a longer period of time. Features Positive Temperature Coefficient (PTC) semiconductor heating element, self regulating and temperature limiting Adjustable thermostat LED lamp for optical indication of function Durable, non-metallic plastic housing, UL9-VO Connection: - pole terminal, max. AWG Easily installed by clip-mounting on 5mm DIN rail CAUTION Do not mount on wooden structures. Avoid placement near heat-sensitive components WCR SERIES FAN HEATERS CATALOG RATED MAX. AMPS THERMOSTAT AXIAL FAN TEMPERATURE DIMENSIONS WATTS NUMBER VOLTAGE (INRUSH CURRENT) ADJUSTABLE FROM BALL BEARING SCALE H X W X D WCR A -0ºF (0-60ºC) 0 CFM Fahrenheit 6.50x.9x5.00 (65x00x8) WCR A -0ºF (0-60ºC) 0 CFM Celsius 6.50x.9x5.00 (65x00x8) WCR A -0ºF (0-60ºC) 6 CFM Fahrenheit 6.50x.9x5.00 (65x00x8) WCR A -0ºF (0-60ºC) 6 CFM Celsius 6.50x.9x5.00 (65x00x8) For spacing, add " clearance for heat sensitive parts

33 K EGL SERIES FAN HEATERS EGL50-0 Industry Standards UL Recognized Component cul Recognized Component CE Recognized Applications Use when larger heating capacities or internal forced air circulation is required. Designed to prevent condensation or maintain minimum temperature in enclosures. Features Heating element is micanite with fail safe thermostat Black, anodized aluminum extruded body Ball bearing life expectancy is 0,000 hrs. at 70ºF (0ºC) Connection: pole terminal for AWG 8 Easily installed by clip mounting on 5mm DIN rails CAUTION Do not mount on wooden structures. Avoid placement near heat-sensitive components Accessories Thermostats (see pages K-K) EGL SERIES FAN HEATERS CATALOG RATED STARTING SURFACE CIRCULATION DIMENSIONS WATTS AXIAL FAN NUMBER VOLTAGE AMPS TEMPERATURE POWER H X W X D EGL ºF Ball Bearing 0 CFM Free Blowing 7.00x.5x.5 (78x80x80) EGL ºF Ball Bearing 0 CFM Free Blowing 7.00x.5x.5 (78x80x80) EGL ºF Ball Bearing 0 CFM Free Blowing 9.76x.5x.5 (5x80x80) EGL ºF Ball Bearing 0 CFM Free Blowing 9.76x.5x.5 (5x80x80) For spacing, add " clearance for heat sensitive parts

34 ETR SERIES THERMOSTATS K ETR0 ETR0F Industry Standards UL Recognized Component cul Recognized Component CE Recognized CSA Rated Applications Designed to provide air temperature control and monitoring in switch gear enclosures that are set up to operate with heaters, fans, filter ventilators, heat exchangers, and/or signal transmitters. When the enclosure reaches the pre-determined set point, temperature contacts in the thermostat are activated and the fan or heater automatically begins to operate. Thermostats prolong the life expectancy of heaters and fans by curtailing their operating hours and also increase the working efficiency of electrical components by exposing them to fewer contaminants from the surrounding environment. Features Normally Closed Thermostat For the control of fan heaters and heaters Normally Open Thermostat For the control of cooling units, fans, filter ventilators or switching, or signal transmitters in the event of overheating Available in Fahrenheit or Celsius scale Thermostatic bi-metallic sensor element Easily installed by clip mounting on 5mm or 8mm DIN rails ETR SERIES THERMOSTATS CATALOG TEMP. TEMP. SWITCHING FOR PRODUCT DIMENSIONS NUMBER SCALE RANGE TYPE H X W X D ETR0F Fahrenheit -0ºF ETR0 Celsius 0-60ºC ETR0F Fahrenheit -0ºF ETR0 Celsius 0-60ºC Normally Closed Normally Closed Normally Open Normally Open Housing made from gray flame retardant UL9-VO plastic Connection: pole terminal for max. AWG Switching Difference (hysteresis): ºF (7ºC) Switching Capacity: 5 A () AC 0V, 0 A () AC 50V, 0A V DC, 5A V DC Heating Heating Cooling Cooling.0x.0x.0 (60xx5).0x.0x.0 (60xx5).0x.0x.0 (60xx5).0x.0x.0 (60xx5)

35 K ETF SERIES THERMOSTATS ETF000 Industry Standards UL Recognized Component cul Recognized Component CE recognized Applications Designed to provide both air temperature and humidity control as well as monitoring in electrical and electronic enclosures. Highly effective in ATM s, parking control gates, ticket dispensers and traffic control systems where equipment is exposed to wide range of outdoor elements. Features Independently senses the relative humidity and temperature. Resistive and inductive loads (heaters or Filterfans ) can be switched 00,000 cycle life expectancy LED lamp for optical indication of function Durable, non metallic plastic gray housing, UL9-VO Easily installed by clip mounting on 5mm DIN rail Switching capacity: 8A() AC 0V, 0.8A DC 8V, 8A DC V ETF SERIES FAN HEATERS SWITCHING RESPONSE CATALOG OPERATING TEMPERATURE TEMPERATURE RELATIVE DIMENSIONS DIFFERENCE TIME NUMBER VOLTAGE SCALE RANGE HUMIDITY RANGE H X W X D (HYSTERESIS) (SECONDS) ETF0000F 0 Fahrenheit Approx..6ºF (ºK) Approx. 60-0ºF 50 to 90%.6x.97x.5 (67x50x9) ETF000 0 Celsius Approx..6ºF (ºK) Approx ºC 50 to 90%.6x.97x.5 (67x50x9)

36 STFX SERIES UNIVERSAL THERMOSTAT MOUNT K5 STFX05 Applications Effective substitute for DIN rail or Unistrut. Multipurpose mounting devise which allow the mounting of small DIN rail mountable appliances reducing time and labor. Features Provides direct snap-in mounting for thermostats, time relays, small heaters, terminals, and other appliances with DIN rail mounting or by the use of screw holes Manufactured from black UL9-VO polyamide material Included self adhesive bears continuous loads of. lbs. (after hours) Holes for screw mounting are provided for heavy applications STFX SERIES UNIVERSAL THERMOSTAT MOUNT CATALOG HOLDING PACKAGE TEMP. RANGE OF DIMENSIONS NUMBER CAPACITY QUANTITY* MOUNTING MATERIAL H X W X D STFX05. lbs. (00g) initially --ºF.50x.70x.55. lbs. (500g) after 5 (-0-55ºC) (8xx) hour curing period *Sold in package quantity only

37 K6 WAFMP SERIES FAN MOUNTING PLATE WAFMP Fan Mounting Plate Description Designed to mount a fan and louver kit together. This fan mounting plate kit consists of a fan mounting plate, filter and all necessary hardware for installation. When ordering a fan mounting plate, you will need to order a fan, louver kit and a fan guard. Fans, louver kits and fan guards must be ordered separately. WAFMP SERIES FAN MOUNTING PLATE CATALOG NUMBER FAN, FILTER & LOUVER LOUVER KIT FAN FAN* MOUNTING PLATE KIT PAINTED** GUARD *** WAFMP WAAXFN WAVK0606 WAGARD WAFMP WAAXFN WAVK0606 WAGARD WAFMP6 WA6AXFN WAVK0808 WAGARD6 WAFMP6 WA6AXFN WAVK0808 WAGARD6 WAFMP0 WA0AXFN WAVK0809 WAGARD0 WAFMP0 WA0AXFN WAVK0809 WAGARD0 *See page K6 for information on fans. **See page K7 for information on louver kits. ***See page K6 for information on guards. Notes: Installation Instructions:. Make sure that the proper kits have been ordered.. Locate and mark holes and cutout per louver kit instructions on page K7-K8.. Assemble kits as shown in figure.. After installation is complete, make sure that no hardware interferes with any internal or external equipment.

38 800 SERIES - FILTER FANS/EXHAUST FILTER & MATS K7 SERIES 80 SERIES 800, 80, 80 Industry standards IP5 IP55 (with fine filter mat) Application The latest passive technology for fan cooling and pressurizing of industrial enclosures Filtered passive ventilation can be provided by an exhaust filter for either convection cooling or in combination with a fan in forced air cooling Features All four models are available in 0 and 0 volt with an expected service life of 50,000 hours Self-adhesive seal on mounting frame prevents dust and water from entering the enclosure The functional design of the intake exhaust fan hoods minimize direct infiltration of falling water By simply turning the axial fan, the direction of the airflow can be changed by 80 degrees Air Channeling makes the filter fan particularly quiet in operation Plastic self-extinguishing UL9-V0 and temperature resistant F to 58F Durable, reusable medium filter mat included RAL705 Light Gray Finish Ball Bearing Axial Fan with plastic impeller UL9V-0. lead wires long (pressure clamps inclusive) Time-Saving Steps 800 Series Fans can be easily connected and installed from the outside of the cabinet.. Remove protective film from the sealing strips provided on the mounting frame. Insert mounting frame into enclosure cutout.. Terminate the axial fan with push type connectors and slide the unit into the mounting frame.. Insert the Filter Mat and snap on the protective Hood. Time-Saving Assembly and Maintenance

39 K8 800 SERIES - FILTER FANS/EXHAUST FILTER & MATS." 5." 5.".6"." 6.".0"." 8."." (8mm).6" (68mm).8" (5mm).8" 5.".9" 6.7" 6.9" 8.9" 9.8" (50mm) 800 SERIES FILTER FAN Catalog No. (for 0V 60Hz) W W W W Catalog No. (for 0V 50Hz) W W W W Filter mat: Medium grade 50 g/m, filtering degree 8%, Particle < 0 µm, G(EN779) Air volume free blowing: cfm ( m /h) 9 cfm (55 m /h) 60 cfm (0 m /h) 76 cfm (00 m /h) with exhaust filter: 9 cfm (6 m /h) cfm ( m /h) 0 cfm (68 m /h) 5 cfm (0 m /h) Current consumption 0V 60 ma 80 ma 80 ma 00 ma 0V 80 ma 00 ma 00 ma 700 ma Power consumption 0V W 5W 5W 60W 0V W 5W 5W 60W Average noise level at ft DIN EN ISO 96- db (A) 0 db (A) 9 db (A) 5 db (A) Mounting depth.8" (5 mm)." (58 mm)." (86 mm).6" (65 mm) Enclosure cut-out.8" x.8" (97 x 97mm +0.).9" x.9" (5 x 5mm +0.) 6.9" x 6.9" (76 x 76mm +0.) 9.8" x 9.8" (50 x 50mm) Weight. lbs (0.5 kg). lbs (.0 kg). lbs (.9 kg) 7.7 lbs (.5 kg) 0V / 60Hz models have increased air volume performance of approx. 5% 800 SERIES EXHAUST GRILLE & FILTER Catalog No. W800F- W80F-5 W80F-7 W80F-0 Filter mat: Medium grade 50 g/m, filtering degree 8%, Particle Ø to 0 µm, G (DIN 85) Mounting depth 0.6" (6 mm) 0.6" (6 mm) 0.6" (6 mm) 9" ( mm) Enclosure cut-out.8" x.8" (97 x 97mm +0.).9" x.9" (5 x 5mm +0.) 6.9" x 6.9" (76 x 76mm +0.) 9.8" x 9.8" (50 x 50mm +.) Weight 0.6 lbs (0.7 kg) 0.8 lbs (0.8 kg). lbs (0.60 kg). lbs (95 kg) REPLACEMENT FILTER MATS Medium filter (G) MM MM MM MM Fine filter (F5) FM0860- FM FM FM MOUNTING FRAME HOLE CENTERS FOR ATTACHING WITH SCREWS - HOLE Ø /8 (MM) X =." (09 mm) X = 5." (7 mm) X = 7." (88 mm) X = 0." (6 mm) X X

40 WPF SERIES FILTERFANS K9 WPF0-5BK Industry Standards UR, cur, and CE recognized IP (IP5 with optional WPFG Series gasket) Applications Most innovative technology for fan cooling and pressurizing of industrial enclosures Provides a high quality, economical method of cooling enclosures Filtered passive ventilation can be provided by an exhaust filter for either convection cooling or in combination with a fan in forced air cooling Slim line design allows grille to protrude from enclosure surface less than one quarter inch Maintains aesthetics of enclosure Features All models are 5V with an expected service life of 0,000 hours High performance fan motors and finger guards Polycarbonate fire retardant plastic grilles, UL9-VO Durable, reusable filter mat included Grilles are available in black or beige Patented Click and Fit system allows for rapid filter fan and exhaust filter installation without screws; this time saving feature will cut installation time by up to 0 minutes from traditional box fan packages Cutout template provided with every unit Fan or exhaust filter simply snaps into cutout opening Connector type: WPF0 Series, " wires. WPF0 WPF60 Series terminal strip Accessories Exhaust Filters Gaskets (WPFG Series) recommended if installing on enclosure with textured finish (only WPF0) Replacement Filters -0/+ mm -0/+ mm WPF0 WPF0-0/+ mm -0/+ mm WPF5 WPF0 WPF50 WPF60

41 K0 WPF SERIES FILTERFANS WPF SERIES FILTERFANS CATALOG NUMBER BLACK GRILLE BEIGE GRILLE FREE FLOW AIR MAX. AMBIENT FILTER SOUND RATED AIR DELIVERY STATIC TEMP. FILTERING REQUIRED CUT OUT DENSITY LEVEL VOLTAGE DELIVERY W/EXHAUST PRESSURE DEGREE F LEVEL DIMENSION (G/M) (DB) (CFM)* (CFM) (PA) MAX/MIN WPF0-5BK WPF0-5 5V / % 9.6x.6 (9x9) WPF0-5BK WPF0-5 5V / % 9.9x.9 (5x5) WPF5-5BK WPF5-5 5V / % x8.78 (x) WPF0-5BK WPF0-5 5V / % x8.78 (x) WPF50-5BK WPF50-5 5V / % 69.6x.6 (9x9) WPF60-5BK WPF60-5 5V / % 7.6x.6 (9x9) *Add 5% for 60Hz WPF0 Air Flow WPF0 Air Flow WPF5 Air Flow WPF0 Air Flow WPF50 Air Flow WPF60 Air Flow

42 WPFA SERIES EXHAUST GRILLE WITH FILTER K WPFA0BK WPFA0 Industry Standards IP (IP5 with optional WPFG Series gasket) Applications Polycarbonate fire retardant plastic grilles, UL9-VO Durable, reusable filter mat included Grilles are available in black or beige Accessories Gaskets (WPFG series) recommended if installing on enclosure with textured finish EXHAUST GRILLE WITH FILTER CATALOG NUMBER FILTER FILTERING REQUIRED CUT OUT BLACK GRILLE BEIGE GRILLE DENSITY (G/M) LEVEL DIMENSIONS WPFA0BK WPFA %.60x.60/9x9 WPFA0BK WPFA0 50 8%.90x.90/5x5 WPFA5/0BK WPFA5/0 50 8% 8.80x8.80/x WPFA50/60BK WPFA50/ %.50x.50/9x9 WPFA 0 WPFA 0 WPFA 5/0 WPFA 50/60

43 K FILTERFAN REPLACEMENT ACCESSORIES WPFG5/0 WPFM0 WPGBK WPG5/0BE GASKETS FOR FILTERFANS Applications Packaged individually Provides added sealing protection Recommended when fans or exhaust grilles are installed on enclosures with textured finishes Changes Filer Fan rating from IP to IP 5 when installed WPFG SERIES GASKET FOR FILTERFANS CATALOG NUMBER GASKET USE WITH FILTER FAN NO. USE WITH EXHAUST GRILL NO. WPFG0 WPFG0 WPFG5/0 WPFG50/60 WPF0-5BK WPF0-5 WPF0-5BK WPF0-5 WPF5-5BK WPF0-5BK WPF5-5 WPF0-5 WPF50-5BK WPF60-5BK WPF50-5 WPF60-5 WPFA0BK WPFA0 WPFA0BK WPFA0 WPFA5BK WPFA0BK WPFA5 WPFA0 WPFA50BK WPFA60BK WPFA50 WPFA60 AC & FILTERFAN REPLACEMENT FILTER MATS Applications Replacement filter mat for WPF-5 Series Filterfans and WPFA Series Exhaust Grilles. Features Packaged in quantities of 5 Made of synthetic fibers Re-usable up to 0 times 00% resistant to humidity AC & FILTERFAN REPLACEMENT FILTER MATS FILTER USE WITH USE WITH MASS FILTER CATALOG FILTER FAN EXHAUST FILTER DENSITY H W NUMBER OR A/C SERIES GRILLE LEVEL % (G/M) WPFM0 WPF0-5 WPFA (85).0 (85) WPFM0 WPF0-5 WPFA (5).50 (5) WPFM5/0 WPFM50/60 WPF5-5 WPF0-5 WPF50-5 WPF60-5 WPFA (0) 8.0 (0) WPFA (80).00 (80) WPFM5/0AC WDTS (0) 8. (0) WPFM50/60AC WDTS (80).00 (80) WPFMDTTAC WDTT (00).8 (00) FILTERFAN REPLACEMENT GRILLES Features Packaged individually Grille only replacement for filter fans Available in black or beige FILTERFAN REPLACEMENT GRILLES CATALOG NUMBER BLACK BEIGE BLACK GRILLE BEIGE GRILLE BLACK BEIGE USE WITH GRILLE GRILLE FOR EXHAUST FOR EXHAUST GRILLE GRILLE A/C UNIT GRILLE FOR FILTER FOR FILTER GRILLE GRILLE FAN FAN W/FILTER W/FILTER WPGBK WPGBE WPF0-5BK WPF0-5 WPFA0BK WPFA0 WPGBK WPGBE WPF0-5BK WPF0-5 WPFA0BK WPFA0 WPGBK WPGBE WDTS WPG5BK WPG5BE WDTS WPF5-5BK WPF5-5 WPFFA5BK WPFA5 WPF0-5BK WPF0-5 WPFA0BK WPFA0 WPF50-5BK WPF50-5 WPFA50BK WPFA50 WPF60-5BK WPF60-5 WPFA60BK WPFA60

Section K Index. Data Subject To Change Without Notice ENVIRONMENTAL CONTROL

Section K Index.   Data Subject To Change Without Notice ENVIRONMENTAL CONTROL General Information/Sizing...K-K MTAB Assembly...K Advantage Series NEMA Type R Air Conditioners 000 BTU RP7 Series, Side Mount, NR...K6 000 BTU RP8 Series, Side Mount, NR...K7 000 BTU RP Series, Side

More information

Thermal Management INDEX. Management. Thermal TM-1

Thermal Management INDEX. Management. Thermal TM-1 Heat builds up rapidly in enclosed environments, compromising the performance and life span of equipment. Like insurance for your electronics, effective thermal management maximizes the efficiency and

More information

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA L14 ENVIRONMENTAL CONTROL Ever since components have been made to control electrotechnical tasks, heat loss has been a subject to take into consideration. Sometimes more sometimes less. Major problems

More information

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ USA Phone: web:

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ USA Phone: web: Humidity and heat are real problems for us. Hoffman is the only company we ve found that offers a full line of environmental management options and has the expertise to apply them. Thermal Management The

More information

KOOLTRONIC ENCLOSURE AIR CONDITIONER QUICK SHEET

KOOLTRONIC ENCLOSURE AIR CONDITIONER QUICK SHEET KOOLTRONIC ENCLOSURE AIR CONDITIONER QUICK SHEET TYPE 4 INDOOR OUTDOOR TYPE 4 480 VOLT INDOOR OUTDOOR TYPE 12, 3R AND 4 (4X OPTIONAL) SLIMKOOL Guardian/ GuardianX Series 4 Rating Maintained ( 4X Rating

More information

Featured Products in this Chapter. Subject to change without notice PH FX hoffmanonline.com 2010 Pentair Technical Products

Featured Products in this Chapter. Subject to change without notice PH FX hoffmanonline.com 2010 Pentair Technical Products : CHAPTER Thermal Management Outdoor Air Conditioners T15, T20 and T29 Series 800-4,000 BTU/Hr. P. 1152 Featured Products in this Chapter Outdoor Air Conditioners T43, T50 and T53 Series 6,680-20,000 BTU/Hr.

More information

RACK-MOUNT Air Conditioners

RACK-MOUNT Air Conditioners RACK-MOUNT Air Conditioners 2000-10000 BTU/HR. 586-2930 WATTS RCR11 LB16 LB14 FEATURES RCR11 is part of the ProAir Series which combines state-of-the-art design with pleasing aesthetics. This rack mount

More information

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page How to Select and Size Enclosure Thermal Management Systems Follow the steps detailed in this white paper for optimal

More information

CHAPTER12. Thermal Management. Featured Products in this Chapter. Outdoor Air Conditioners T15, T20 and T29 Series 800-4,000 BTU/Hr. P.

CHAPTER12. Thermal Management. Featured Products in this Chapter. Outdoor Air Conditioners T15, T20 and T29 Series 800-4,000 BTU/Hr. P. PH FX (763) 422-2600 422-2211 : CHAPTER12 Thermal Management Featured Products in this Chapter Outdoor Air Conditioners T15, T20 and T29 Series 800-4,000 BTU/Hr. P. 1156 Outdoor Air Conditioners T43, T50

More information

GENESIS Indoor Air Conditioners

GENESIS Indoor Air Conditioners Product Overview : Indoor Air Conditioners M28 Model M52 460 Volt 3-Phase Model M17 Model 68 68 Product Overview : The specifier s choice for cooling industrial process controls Indoor Air Conditioners

More information

Quality Enclosures. Service Excellence.

Quality Enclosures. Service Excellence. Cooling Products General Information...5 General Selection Considerations...5 Sizing an Air Conditioner...6 General Specifications for Air Conditioners...7 Side Mounting DTS Series Air Conditioners 1200

More information

Cabinet Cooler Systems

Cabinet Cooler Systems Cooler Systems Cooler Systems Stop electronic control downtime due to heat, dirt, and moisture! maintain NEMA 4, 4X, and 12 integrity. All are and compliant! What is an EXAIR Cooler System? A low cost,

More information

Power to be dissipated (Watts) x 3.17 Maximum Allowable Internal Temperature ( F) - Maximum Ambient Temperature ( F)

Power to be dissipated (Watts) x 3.17 Maximum Allowable Internal Temperature ( F) - Maximum Ambient Temperature ( F) Blowers and Fans General Selection Considerations General Specifications All Hammond blowers and filter fans are engineered for performance and built for reliability. This versatile line includes a blower,

More information

Top-Mount Air Conditioners

Top-Mount Air Conditioners Product Overview Top-Mount Air Conditioners MHB11 Model 92 92 Product Overview The perfect cooling solution when side-mount air conditioning is not an option Top-Mount Air Conditioners PRODUCT OVERVIEW

More information

T BTU/Hr. 234 Watts. T BTU/Hr. 586 Watts. Air Conditioners

T BTU/Hr. 234 Watts. T BTU/Hr. 586 Watts. Air Conditioners 763.576.32 Spec-733 C763.422.2211 Sealed Enclosure Air Conditioners Sealed Enclosure Air Conditioners T-SERIES Compact Outdoor T15 8 BTU/Hr. 234 Watts T2 2 BTU/Hr. 586 Watts INDUSTRY STANDARDS UL/cUL Listed;

More information

Quality Products. Service Excellence.

Quality Products. Service Excellence. Cooling Products General Information...347 Sizing an Air Conditioner...348 Side Mounting DTS Series 1200 BTU/H NEMA 12...349 Side Mounting DTS Series 2000 BTU/H NEMA 12...350 Side Mounting DTS Series 2500

More information

PROAIR Harsh Environment/Wash Down Air Conditioners

PROAIR Harsh Environment/Wash Down Air Conditioners PH FX ( Product Overview McLean Cooling Technology: Air Conditioners: Harsh Environment/Wash Down Air Conditioners CR23 CR23st CR43st CR29 102 Product Overview : The ultimate in protective cooling for

More information

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner ADVANTAGE RP55 SERIES

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner ADVANTAGE RP55 SERIES ADVANTAGE RP55 SERIES Keep This Manual With Air Conditioner AIR CONDITIONER OPERATOR'S MANUAL BEFORE INSTALLING AND USING THIS AIR CONDITIONER, IT IS IMPORTANT THAT THIS MANUAL BE READ AND UNDERSTOOD THOROUGHLY

More information

Quality Enclosures. Service Excellence.

Quality Enclosures. Service Excellence. Cooling Products General Information...387 Sizing an Air Conditioner...388 General Specifications for All Air Conditioners...389 Side Mounting DTS Series - 1200 BTU/H - NEMA 12...390 Side Mounting DTS

More information

SPECTRACOOL Indoor & Outdoor Air Conditioners

SPECTRACOOL Indoor & Outdoor Air Conditioners PH FX ( Product Overview : SPECTRACOOL Indoor & Outdoor Air Conditioners G52 Indoor Model G57 Outdoor Model G28 Indoor Model 18 18 Product Overview : Makes electronics cooling easier, so you can go about

More information

Enclosure Cooling, Venting, Heating & Purging Solutions. Celebrating 20 Years of Excellence

Enclosure Cooling, Venting, Heating & Purging Solutions. Celebrating 20 Years of Excellence Enclosure Cooling, Venting, Heating & Purging Solutions Celebrating 20 Years of Excellence Enclosure Climate Control Table of Contents Closed Loop Air Conditioners Pgs 3-18 Thermoelectric Cooling Pgs 32-35

More information

N Volt 1800 BTU/Hr. 527 Watt. Specifications. Finish. Notes

N Volt 1800 BTU/Hr. 527 Watt. Specifications. Finish. Notes Spec-75 A( McLean Electronics Cooling Sealed Enclosure Cooling McLean Electronics Cooling: Sealed Enclosure Cooling SPECTRACOOL Compact Indoor N17 115/23 Volt 1 BTU/Hr. Watt N17 46 Volt 18 BTU/Hr. 527

More information

KNHX32 SERIES NEMA 4/4X AIR-TO-AIR HEAT EXCHANGERS

KNHX32 SERIES NEMA 4/4X AIR-TO-AIR HEAT EXCHANGERS Keep This Manual With Heat Exchanger Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents KNHX2 SERIES NEMA /X AIR-TO-AIR HEAT EXCHANGERS

More information

N Volt 1800 BTU/Hr. 527 Watt

N Volt 1800 BTU/Hr. 527 Watt 763.576.32 SPEC-75 F763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS SPECTRACOOL COMPACT INDOOR N17 115/23 Volt BTU/Hr. Watt N17 46 Volt 18 BTU/Hr. 527 Watt INDUSTRY STANDARDS UL/cUL Listed;

More information

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner INTEGRITY SERIES K_NA4C4P32L KNA6C4P32L

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner INTEGRITY SERIES K_NA4C4P32L KNA6C4P32L INTEGRITY SERIES K_NA4C4P32L KNA6C4P32L Keep This Manual With Air Conditioner Find additional information on this model at kooltronic.com, or use the Technical Documents QR code below. Technical Documents

More information

N Volt 1800 BTU/Hr. 527 Watt

N Volt 1800 BTU/Hr. 527 Watt Spec-75 B Sealed Enclosure Air Conditioners Sealed Enclosure Air Conditioners SPECTRACOOL Compact Indoor N17 115/23 Volt 1 BTU/Hr. Watt N17 46 Volt 18 BTU/Hr. 527 Watt INDUSTRY STANDARDS UL/cUL Listed;

More information

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER Keep This Manual With Heat Exchanger Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

More information

Guardian/GuardianX Series NEMA 4 or 4X Rated Air Conditioners. Air Conditioners:

Guardian/GuardianX Series NEMA 4 or 4X Rated Air Conditioners. Air Conditioners: Air Conditioners:» Advantage Guardian Guardian 480 Intrepid Mini Profile Profile 480 Rack Mount Top Mount Traditional TrimLine Water-Cooled Guardian/GuardianX Series NEMA 4 or 4X Rated Air Conditioners

More information

Climate Control Products

Climate Control Products 342 Cooling Products General Information... 344 General Selection Considerations... 345 Air Conditioner Design Features... 346 Sizing an Air Conditioner... 347 General Specifications for Air Conditioners...

More information

Indoor and Outdoor Enclosures Outdoor Nema 3, 3R, 4, 4X Cabinet Enclosures LTE 4G Wimax Telecom Security Traffic

Indoor and Outdoor Enclosures Outdoor Nema 3, 3R, 4, 4X Cabinet Enclosures LTE 4G Wimax Telecom Security Traffic Spec-00698 APH FX ( Protective Cooling Air Conditioners N28 Narrow Indoor/Outdoor Base Models Features R407c and R134a earth-friendly refrigerants and RoHS compliant Models for 115, 230 AC volt power input

More information

Keep Electrical Enclosures Cool, Clean and Protected

Keep Electrical Enclosures Cool, Clean and Protected Enclosure Coolers Keep Electrical Enclosures Cool, Clean and Protected Have your production lines or equipment ever shutdown from overheated electrical enclosures? It s a common problem, and one that can

More information

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner TRIMLINE NP28 SERIES KA4C4NP28L with Serial Numbers up to and including L16A3713 K2A4C4NP28L with Serial Numbers up to and including E16A1554 Keep This Manual With Air Conditioner Find additional information

More information

Submittal Data Performance Data Electrical Data

Submittal Data Performance Data Electrical Data ERMS Series Submittal Data Submittal Data Unit Designation: Job name: Architect: Engineer: Contractor: Performance Data Revision: 07/01/11 Cooling Capacity: EER: Heating Capacity: COP: Ambient Air Temp:

More information

KNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER

KNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER Keep This Manual With Heat Exchanger Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents KNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER

More information

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes Spec-728 CPH FX ( McLean Electronics Cooling Sealed Enclosure Cooling McLean Electronics Cooling: Sealed Enclosure Cooling SPECTRACOOL Indoor/Outdoor G57 2 BTU/Hr. 5861 Watt G52 8/12 BTU/Hr. 23/35 Watt

More information

VA G 052 S

VA G 052 S 763.576.3200 SPEC-00746 D763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners V-SERIES COMPACT AIR CONDITIONERS VA06 Indoor Model 400 and 600 Watts INDUSTRY

More information

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners V-Series Mid-Size Air Conditioners (Now done by MGDC) VA08 Indoor Model 1200, 1500 and 2000 Watts INDUSTRY STANDARDS IP 56 Internal Air Loop IP 34 External Air Loop APPLICATION Industrial drive enclosures

More information

NOREN Products. Compact Cabinet Coolers

NOREN Products. Compact Cabinet Coolers NOREN Products Back to INTRODUCTION Inc. 3 Noren Products Inc. produces a broad range of heat transfer devices incorporating heat pipes. Several of the company's products are widely recognized by their

More information

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER Keep This Manual With Heat Exchanger Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

More information

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER Keep This Manual With Heat Exchanger Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

More information

SPECTRACOOL INDOOR/OUTDOOR

SPECTRACOOL INDOOR/OUTDOOR SPEC-728 E SEALED ENCLOSURE AIR CONDITIONERS SEALED ENCLOSURE AIR CONDITIONERS SPECTRACOOL INDOOR/OUTDOOR G57 2 BTU/Hr. 5861 Watt G52 8/12 BTU/Hr. 23/35 Watt G28 4/6 BTU/Hr. 1172/ Watt Clean AirFlow Ambient

More information

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners 763.576.3200 SPEC-00747 D763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners V-SERIES MID-SIZE AIR CONDITIONERS VA08 Indoor Model 1200, 1500 and 2000

More information

AIR TO AIR HEAT EXCHANGERS

AIR TO AIR HEAT EXCHANGERS AIR TO AIR HEAT EXCHANGERS HEAT PIPE TECHNOLOGY CLOSED LOOP DESIGN AVAILABLE IN 120, 230, 24VDC & 48VDC NEMA TYPE 12, 4 AND 4X UL LISTED FOR STANDARD AND HAZARDOUS LOCATIONS A2A SERIES AIR TO AIR HEAT

More information

SPECTRACOOL Indoor & Outdoor Air Conditioners

SPECTRACOOL Indoor & Outdoor Air Conditioners Product Overview : SPECTRACOOL Indoor & Outdoor Air Conditioners G52 Indoor Model G57 Outdoor Model 18 Product Overview : Makes electronics cooling easier, so you can go about your business SPECTRACOOL

More information

5736 N. Michigan Road Indianapolis, IN 46228

5736 N. Michigan Road Indianapolis, IN 46228 763.576.3200 SPEC-00728 H763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners SPECTRACOOL INDOOR/OUTDOOR G57 BTU/Hr. Watt G52 / BTU/Hr. 2300/3500 Watt

More information

5736 N. Michigan Road Indianapolis, IN 46228

5736 N. Michigan Road Indianapolis, IN 46228 763.576.32 SPEC-728 H763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners SPECTRACOOL INDOOR/OUTDOOR G57 2 BTU/Hr. 5861 Watt G52 8/12 BTU/Hr. 23/35 Watt

More information

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner Keep This Manual With Air Conditioner MICRO-MINI* SUPER-MINI NARROW-MINI *For Micro-Mini units with Serial Numbers up to A17A0030 Find additional information on this model at kooltronic.com or use the

More information

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner WATER-COOLED RACK MOUNTED

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner WATER-COOLED RACK MOUNTED WATER-COOLED RACK MOUNTED Keep This Manual With Air Conditioner AIR CONDITIONER OPERATOR'S MANUAL CAUTION BEFORE INSTALLING AND USING THIS AIR CONDITIONER, IT IS IMPORTANT THAT THIS MANUAL BE READ AND

More information

Typical Applications. Braking Resistor Core Drying Dehumidification Forced Air Comfort Heating

Typical Applications. Braking Resistor Core Drying Dehumidification Forced Air Comfort Heating Process air duct heaters are used for tempering forced air in many industrial processes. Heater wattage is dependent on air outlet temperature (up to 1200 F [650 C]) and air velocity. Smaller duct heaters

More information

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through tons, up to 7,800 BTUH Heating The SPXB-HW Series "Suite 0" is a compact, throughthe-wall single package vertical HVAC

More information

G /6000 BTU/Hr. 1172/1758 Watt

G /6000 BTU/Hr. 1172/1758 Watt Spec-728 E Sealed Enclosure Air Conditioners Sealed Enclosure Air Conditioners SPECTRACOOL Indoor/Outdoor G57 2 BTU/Hr. 5861 Watt G52 8/12 BTU/Hr. 23/35 Watt G28 4/6 BTU/Hr. 1172/ Watt Clean AirFlow Ambient

More information

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation Industrial Space Heating Direct Gas-Fired Heating Greenheat 00% Outdoor Air Greenheat 50/50 Recirculation 80/0 Recirculation March 008 Product Overview Industrial Space Heating Greenheck s space heating

More information

Wall Mounted Air Conditioners with Gas Heat Models AVGA

Wall Mounted Air Conditioners with Gas Heat Models AVGA PRODUCT DATA SHEET Wall Mounted Air Conditioners with Gas Heat Models AVGA24-30-36-42-48-60 General Description The Marvair GPac wall mounted air conditioner with gas heat is designed for use on a variety

More information

Indirect Gas-Fired Make-Up Air

Indirect Gas-Fired Make-Up Air Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041 Product Features Model IG Indirect Gas-Fired Make-Up

More information

SEALED ENCLOSURE COOLING

SEALED ENCLOSURE COOLING ADVANCED COOLING TECHNOLOGIES The Thermal Management Experts www.1-act.com SEALED ENCLOSURE COOLING ABOVE-AMBIENT AND SUB-AMBIENT COOLING PRODUCTS TABLE OF CONTENTS HEAT SINK COOLER (ACT-HSC) HEAT EXCHANGER

More information

PTAC 2017 Air Conditioner Collection

PTAC 2017 Air Conditioner Collection PTAC 2017 Air Conditioner Collection PTAC COLLECTION The Frigidaire 2017 PTAC Collection offers flexibility for any application. Simple, intuitive controls and options, including remote thermostats, allow

More information

T-Series Air Conditioner T20 Model

T-Series Air Conditioner T20 Model INSTRUCTION MANUAL T-Series Air Conditioner T20 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

G /6000 BTU/Hr. 1172/1758 Watt

G /6000 BTU/Hr. 1172/1758 Watt SPECTRACOOL Indoor/Outdoor G57 2 BTU/Hr. 5861 Watt G52 8/12 BTU/Hr. 23/35 Watt G28 4/6 BTU/Hr. 1172/ Watt Clean AirFlow Ambient AirFlow INDUSTRY STANDARDS UL/cUL Listed; Type 12, 3R, 4; 4X optional; File

More information

E Z S E R I E S " W X 16" H

E Z S E R I E S  W X 16 H PACKAGED TERMINAL AIR CONDITIONER E Z S E R I E S 4 2 42" W X 16" H Perfect Fit for Replacing Existing 42" X 16" Units and for New Construction Projects M A N U FA C T U R E R O F Q U A L I T Y A I R C

More information

FRIGIDAIRE PTAC COLLECTION AIR CONDITIONERS

FRIGIDAIRE PTAC COLLECTION AIR CONDITIONERS FRIGIDAIRE PTAC COLLECTION AIR CONDITIONERS 1 PTAC The Frigidaire PTAC Collection offers flexibility for any application. Simple, intuitive controls and options, including remote thermostats, allow users

More information

Enclosure Cooling Solutions

Enclosure Cooling Solutions Enclosure Cooling Solutions Air Conditioners Heat Exchangers Fans Blowers Enclosure Accessories 9001 Solve your enclosure cooling problems! KOOLTRONIC offers: Large inventory of Air Conditioners, Heat

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

KUH. Horizontal Unit Heater. Applications. Description

KUH. Horizontal Unit Heater. Applications. Description KUH KUH PDS Horizontal Unit Heater 2.6 kw to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)

More information

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner GUARDIAN SERIES K2NA6C14DP50L

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner GUARDIAN SERIES K2NA6C14DP50L GUARDIAN SERIES K2NA6C14DP50L Keep This Manual With Air Conditioner AIR CONDITIONER OPERATOR'S MANUAL CAUTION BEFORE INSTALLING AND USING THIS AIR CONDITIONER, IT IS IMPORTANT THAT THIS MANUAL BE READ

More information

T-Series Air Conditioner T53 Model

T-Series Air Conditioner T53 Model INSTRUCTION MANUAL T-Series Air Conditioner T53 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED (491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

CLe-series Dishwashers

CLe-series Dishwashers CLe-series Dishwashers Blower-dryer electric (CLe SERIES) ML-138211 ML-138212 ML-138213 ML-138214 electric (CLeR SERIES) ML-138325 ML-138326 ML-138327 ML-138328 STEAM (CLe SERIES) ML-138226 ML-138227 ML-138228

More information

Service Parts for RMR Wall-Mount Enclosures

Service Parts for RMR Wall-Mount Enclosures Door Kits for RMR Wall-Mount Enclosures Replacement doors for RMR Wall-Mount Enclosures are removable and can be easily replaced if a door is damaged. Order latch separately. Several options are available:

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

built-in comfort GE built-in air conditioners New product introductions January 2010

built-in comfort GE built-in air conditioners New product introductions January 2010 built-in comfort GE built-in air conditioners New product introductions January 2010 2 geappliances.com A refreshing choice in air conditioning comfort Some choices are easy like those days when the outdoors

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed

More information

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner K2A3C8P36LFHN-1

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner K2A3C8P36LFHN-1 K2A3C8P36LFHN-1 Keep This Manual With Air Conditioner AIR CONDITIONER OPERATOR'S MANUAL CAUTION BEFORE INSTALLING AND USING THIS AIR CONDITIONER, IT IS IMPORTANT THAT THIS MANUAL BE READ AND UNDERSTOOD

More information

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13 R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.

More information

revolutionary new way to cool your electrical enclosures

revolutionary new way to cool your electrical enclosures Get ready for a revolutionary new way to cool your electrical enclosures PFANNENBERG KINETIC SYSTEM THERMAL MANAGEMENT FOR ELECTRICAL ENCLOSURES The Technology of Cooling for Electric Enclosures Description

More information

Description. Construction

Description. Construction LUH LUH PDS Horizontal Unit Heater 2.6 to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)

More information

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features. Spot Cooling Systems, Inc. 120 Century Drive Suite 00 Carrollton, TX 7006 00-6-776 Operation Manual SCT1B and SCT1B Warning! Improper installation, adjustment, alteration, service, or maintenance can cause

More information

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner DP SERIES K_A4C5DP33L

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner DP SERIES K_A4C5DP33L DP SERIES K_A4C5DP33L Keep This Manual With Air Conditioner Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents AIR CONDITIONER

More information

T-Series Air Conditioner T15 Model

T-Series Air Conditioner T15 Model INSTRUCTION MANUAL T-Series Air Conditioner T15 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N GENESIS Air Conditioners All Models INSTRUCTION MANUAL Rev. K P/N 89104462 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

Packaged Terminal Air Conditioner (PTAC)

Packaged Terminal Air Conditioner (PTAC) Packaged Terminal Air Conditioner (PTAC) Air Conditioner / Heat Pump / Backup Electric Heater 16" 42" Depth 21-3/4" More Easy-To-Use Features Comfort Control Design Simple controls allow guests to customize

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N SPECTRACOOL Air Conditioner N21 Model INSTRUCTION MANUAL Rev. G P/N 89115088 TABLE OF CONTENTS WARRANTY AND RETURN POLICY...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N T-SERIES Air Conditioner T43 Model INSTRUCTION MANUAL Rev. I P/N 10-1008-145 TABLE OF CONTENTS Warranty and Return Policy...2 IMPORTANT NOTICE...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

VERTICAL FAN COIL UNITS

VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote

More information

INSTALLATION INSTRUCTIONS FOR MINI MAKE-UP AIR MODEL FER

INSTALLATION INSTRUCTIONS FOR MINI MAKE-UP AIR MODEL FER INSTALLATION INSTRUCTIONS FOR MINI MAKE-UP AIR MODEL FER September 2017 VERSION 1.5 Please read instructions carefully before installation. This unit is a complete fresh air make-up package with an integrated

More information

Ambient (ºF) Temperature Rise Above

Ambient (ºF) Temperature Rise Above Spec-00488 Heat CPH FX (763) Dissipation 422-2600 422-2211 in Electrical Enclosures Technical Thermal Management Information Heat Dissipation in Sealed Electrical Enclosures The accumulation of heat in

More information

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater Toll-Free: 1-800-462-4983 Hazardous Location Fan Forced Unit Heater 3-25KW for Class I, Group C & D, Division 1 & 2 and Class II, Groups E, F & G, Divisions 1 & 2. Designed for rugged industrial applications

More information

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions. Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS Technical Bulletin Products that provide lasting solutions. Krack Corporation has a long tradition of leadership and

More information

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N T-SERIES Air Conditioner T20 Model INSTRUCTION MANUAL Rev. C P/N 89114993 TABLE OF CONTENTS Warranty and Return Policy... 2 IMPORTANT NOTICE... 2 RECEIVING THE AIR CONDITIONER... 3 HANDLING AND TESTING

More information

built-in comfort GE built-in air conditioners and heat pumps

built-in comfort GE built-in air conditioners and heat pumps built-in comfort GE built-in air conditioners and heat pumps Comforting solutions Selecting a GE air conditioner is not only good for the occupant and guests, it s a decision that will leave you resting

More information

Q SERIES MEDIUM TEMPERATURE REFRIGERATORS

Q SERIES MEDIUM TEMPERATURE REFRIGERATORS Item # Quantity C.S.I. Section 11400 FOOD EQUIPMENT Q SERIES MEDIUM STANDARD FEATURES Choice of finishes: Stainless steel exterior and interior; Stainless steel exterior, DuraFinish aluminum interior Galvanized

More information

Packaged Terminal Air Conditioner (PTAC)

Packaged Terminal Air Conditioner (PTAC) FRP12ETT2R Air Conditioner / Electric Heater Product Dimensions Height 16" Width 42" Depth 13-13/16" More Easy-To-Use Features Comfort Control Design Simple controls allow guests to customize their settings,

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with NOVATIONt Coil Sizes 08, 12, 14 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED

More information

ADVANTAGE SERIES KXRP47 AIR-TO-AIR HEAT EXCHANGER

ADVANTAGE SERIES KXRP47 AIR-TO-AIR HEAT EXCHANGER Keep This Manual With Heat Exchanger Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents ADVANTAGE SERIES KXRP47 AIR-TO-AIR HEAT

More information