Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant,

Size: px
Start display at page:

Download "Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant,"

Transcription

1 AVAILABLE SIZES: CERTIFICATION: Nominal sizes available from 018 through 060 to meet the needs of residential and light commercial applications. All models are listed with UL, c-ul, ARI, CEC, and CSA- EEV. ELECTRICAL RANGE: Units are offered in v, single phase 018 through 060 sizes; 208/230v, three phase in 036, 048 and 060 sizes; and 460v, three phase in 060 size. FAN MOTOR: CABINET: The totally enclosed fan motor provides greater reliability under adverse conditions and dependable performance for many years. The permanent split capacitor type motor was designed for optimum efficiency. The motor was then qualified under extreme conditions to help ensure a long, reliable life. A weather protective cabinet of steel is protected with a galvanized coating and treated with a layer of zinc phosphate. A coat of modified polyester powder coating is then applied and baked on, providing each unit with a hard, smooth finish that will last for many years. All screws on cabinet exterior are FEATURES UNIT DESIGN: COMPRESSOR: SERVICE VALVES: SERVICEABILITY: coated for a long-lasting, rustresistant, quality appearance. The copper tube, enhanced sine wave, aluminum fin coil is designed for optimum heat transfer. Vertical air discharge carries sound and hot condenser air up and away from adjacent patio areas and foliage. The base pan is designed for easy removal of water, dirt, and leaves. Each compressor is protected with internal temperature- and current-sensitive overloads. An internal pressure relief valve provides high-pressure protection to the refrigerant system. Both service valves are brass, front seating type with sweat connections. Valves are externally located so refrigerant tube connections can be made quickly and easily. Each valve has a service port for ease of checking operating refrigerant pressures. One panel provides access to electrical controls. Removal of top gives access to fan motor, compressor, and condenser coil. Model PA10 ELECTRIC CONDITIONER SS-PA10-06

2 NOTES: 1. Allow 30 in. clearance to service side of unit, 48 in. above unit, 6 in. on one side, 12 in. on remaining side, and 24 in. between units for proper airflow. 2. Minimum outdoor operating ambient in cooling mode is 55 F max 125 F. 3. Series designation is the 14th position of the unit model number. 4. Center of gravity. A 3/ 8 IN. DIA TIEDOWN KNOCKOUTS (2) PLACES IN IN DISCHARGE IN DISCHARGE DISCHARGE FIELD POWER SUPPLY CONN 7 / 8 IN. DIA HOLE WITH 1 1 / 8 IN. DIA KNOCKOUT AND 1 3 / 8 IN. DIA KNOCKOUT FIELD CONTROL SUPPLY CONN 7 / 8 IN. DIA HOLE B J N P 3 / 8 IN. DIA LIQUID LINE CONN DISCHARGE IN 2 7 / 8 C E M F D DIA VAPOR LINE CONN 1 1 / 4 A937 DIMENSIONS (IN.) UNIT SIZE SERIES A B C D E F J M N P NOTE: The data in this publication is displayed for all series, however, every series may not be available from manufacturer. SHIPPING WEIGHT (Lb) 018 C 22-1/ /16 3-3/16 5/8 18-1/2 4-1/16 8-3/ /8 12-1/4 9-3/ C 22-1/ /16 3-3/16 5/8 18-1/2 4-1/16 8-3/ /8 12-1/4 10-3/ C 22-1/ /16 3-3/16 3/4 18-1/2 4-1/16 8-3/ /8 12-1/4 11-1/ C 22-1/ /16 3-3/16 3/4 18-1/2 4-1/16 8-3/ /8 12-1/4 11-3/ C 22-1/ /16 3-1/4 7/8 18-1/2 4-1/16 8-3/ /8 12-1/4 11-3/ C 22-1/ /16 3-1/4 7/8 18-1/2 4-1/16 8-3/ /8 12-1/ C 22-1/ /16 3-1/4 7/8 18-1/2 4-1/16 8-3/ /8 12-1/ C /16 3-1/4 7/8 23-1/2 6-1/ / REGISTERED QUALITY SYSTEM UNITARY CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. 2

3 See notes on page 5. METERING DEVICE PISTON* UNIT SIZE-SERIES IDENTIFICATION NO. 018-C C C C C C C C 93 * Piston listed is for any approved coil non-capillary tube combination. Piston is shipped with outdoor unit and must be installed in an approved indoor coil. SPECIFICATIONS UNIT SIZE SERIES C C C ELECTRICAL Unit Volts Hertz Phase Operating Voltage Range* Compressor Rated Load Amps Locked Rotor Amps Condenser Fan Motor Full Load Amps Min Unit Ampacity for Wire Sizing Min Wire Size (60 C/75 F Copper) AWG 14/14 14/14 14/14 Max Wire Length (60 C/75 F) (Ft) 66/ 53/50 39/37 Max Branch Circuit Fuse Size** COMPRESSOR & REFRIGERANT Compressor Manufacturer Bristol Type Reciprocating Temperature and Current Protection Internal Line Break Refrigerant Type and Amount (Lbs) R R R Refrigerant Tubes (In. OD) Vapor and Liquid (Up to 50 Ft) 5/8 and 3/8 3/4 and 3/8 CONDENSER COIL & FAN Coil Face Area (Sq Ft) Fan Motor HP, Type, and RPM 1/12 PSC and /10 PSC and 1125 Volts Hertz Phase 208/ Condenser Airflow (CFM) OPTIONAL EQUIPMENT Cycle Protector KSACY0101AAA Start Assist PTC Type KAACS0201PTC Start Assist Capacitor/Relay Type KSAHS0901AAA Low-Pressure Switch KAALP0101LPS High-Pressure Switch KSAHI0101HPS Time-Delay Relay KAATD0101TDR Winter Start Control KAAWS0101AAA Evaporator Freeze Thermostat KAAFT0101AAA Crankcase Heater KAACH1001AAA Liquid Line Solenoid Valve KAALS0101LLS Filter Drier P S Coastal Filter KAACF0401MED TXV Kit (RPB) KAATX0201RPB KAATX0301RPB KAATX0401RPB TXV (Hard Shutoff) KSATX0601HSO Thermostat, Manual Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATPPBAC01-B Thermostat, Manual Changeover, 5-2-Day Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATPPSAC01-B Backplate for Standard Thermostat TSTATXXBBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Outdoor Air Temperature Sensor TSTATXXSEN01-B MotorMaster Control 32LT Ball Bearing Fan Motor HC34GE232 3

4 SPECIFICATIONS Continued UNIT SIZE SERIES C C C ELECTRICAL Unit Volts Hertz Phase Operating Voltage Range* Compressor Rated Load Amps Locked Rotor Amps Condenser Fan Motor Full Load Amps 1.4 Min Unit Ampacity for Wire Sizing Min Wire Size (60 C/75 F Copper) AWG 12/12 10/10 Max Wire Length (60 C/75 F) (Ft) 57/54 67/63 Max Branch Circuit Fuse Size** COMPRESSOR & REFRIGERANT Compressor Manufacturer Bristol Millennium Type Reciprocating Scroll Temperature and Current Protection Internal Line Break Refrigerant Type and Amount (Lbs) R R R Refrigerant Tubes (In. OD) Vapor and Liquid (Up to 50 Ft) 3/4 and 3/8 7/8 and 3/8 CONDENSER COIL & FAN Coil Face Area (Sq Ft) Fan Motor HP, Type, and RPM 1/4 PSC and 1125 Volts Hertz Phase 208/ Condenser Airflow (CFM) 2500 OPTIONAL EQUIPMENT Cycle Protector KSACY0101AAA Start Assist PTC Type KAACS0201PTC Start Assist Capacitor/Relay Type KSAHS1901AAA KSAHS1501AAA KSAHS1601AAA Low-Pressure Switch KAALP0101LPS High-Pressure Switch KSAHI0101HPS Time-Delay Relay KAATD0101TDR Winter Start Control KAAWS0101AAA Evaporator Freeze Thermostat KAAFT0101AAA Crankcase Heater KAACH1001AAA KAACH1201AAA Liquid Line Solenoid Valve KAALS0101LLS Filter Drier P S P S Coastal Filter KAACF0401MED TXV Kit (RPB) KAATX0501RPB KAATX0601RPB TXV (Hard Shutoff) KSATX0601 HSO KSATX0701HSO Thermostat, Manual Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATPPBAC01-B Thermostat, Manual Changeover, 5-2-Day Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATPPSAC01-B Backplate for Standard Thermostat TSTATXXBBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Outdoor Air Temperature Sensor TSTATXXSEN01-B MotorMaster Control 32LT Ball Bearing Fan Motor HC40GE232 See notes on page 5. 4

5 SPECIFICATIONS Continued UNIT SIZE SERIES C C C C C ELECTRICAL Unit Volts Hertz Phase / / Operating Voltage Range* Compressor Rated Load Amps Locked Rotor Amps Condenser Fan Motor Full Load Amps Min Unit Ampacity for Wire Sizing Min Wire Size (60 C/75 F Copper) AWG 8/10 14/14 8/8 12/12 14/14 Max Wire Length (60 C/75 F) (Ft) 97/59 41/39 82/78 58/55 152/144 Max Branch Circuit Fuse Size** COMPRESSOR & REFRIGERANT Compressor Manufacturer Millennium Type Scroll Temperature and Current Protection Internal Line Break Refrigerant Type and Amount (Lbs) R R Refrigerant Tubes (In. OD) Vapor and Liquid (Up to 50 Ft) 7/8 and 3/8 1-1/8 and 3/8 CONDENSER COIL & FAN Coil Face Area (Sq Ft) Fan Motor HP, Type, and RPM 1/4 PSC and 1125 Volts Hertz Phase Condenser Airflow (CFM) OPTIONAL EQUIPMENT Cycle Protector KSACY0101AAA Start Assist PTC KAACS0201PTC N/A KAACS0201PTC N/A Start Assist Capacitor/RelayType KSAHS1601AAA N/A KSAHS1601AAA N/A Low-Pressure Switch KAALP0101LPS High-Pressure Switch KSAHI0101HPS Time-Delay Relay KAATD0101TDR Winter Start Control KAAWS0101AAA Evaporator Freeze Thermostat KAAFT0101AAA Crankcase Heater KAACH1201AAA KAACH1301AAA Liquid Line Solenoid Valve KAALS0101LLS Filter Drier P S Coastal Filter KAACF0401MED KAACF0501LRG TXV Kit (RPB) KAATX0601RPB KAATX0701RPB TXV Hard Shutoff KSATX0701HSO Thermostat, Manual Changeover, Non-Programmable, F/ C, 1 Stage Heat, 1 Stage Cool TSTATPPBAC01-B Thermostat, Manual Changeover, 5-2-Day Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATPPSAC01-B Backplate for Standard Thermostat TSTATXXBBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Outdoor Air Temperature Sensor TSTATXXSEN01-B MotorMaster Control 32LT LT Ball Bearing Fan Motor HC40GE232 HC40GE4 * Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure. If wire is applied at ambient greater than 30 C (86 F), consult Table of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60 C (140 F) conductors, per the NEC (ANSI/NFPA 70) Article Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. ** Time-delay fuse or circuit breaker. Start assist capacitor and relay required when using liquid solenoid valve or hard shutoff TXV (except 048 and 060 Sizes). Do not use hard shutoff TXV with liquid solenoid valve. Furnace model numbers P08UA, P08LA, and PG8HA are not compatible with this thermostat. N/A Not applicable in this application. NOTES: 1. Control circuit is 24v on all units and requires external power source. 2. All motors/compressors contain internal overload protection. 3. Copper wire must be used from service disconnect to unit. 5

6 ACCESSORY USAGE GUIDELINE ACCESSORY REQUIRED FOR LOW-AMBIENT APPLICATIONS (Below 55 F) REQUIRED FOR LONG-LINE APPLICATIONS* (Over 50 Ft) REQUIRED FOR SEA COAST APPLICATIONS (Within 2 Miles) Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Winter Start Control Yes No No Accumulator No No No Compressor Start Assist Capacitor and Relay Yes Yes No MotorMaster Control Yes No No Wind Baffle See low-ambient instructions No No Coastal Filter No No Yes Support Feet Recommended No Recommended Liquid-Line Solenoid Valve or Hard Shutoff TXV * For tubing line sets between 50 and 175 ft, refer to Residential s Split s Long-Line Application Guidelines. Only when low-pressure switch is used. No See Long-Line Application Guideline Ball Bearing Fan Motor Yes No No No ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) 1. Ball Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. SUGGESTED USE: Required on all units where Low-Ambient kit (full modulation feature) or MotorMaster Control has been added. 2. Coastal Filter A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow. SUGGESTED USE: In geographic areas where salt damage could occur. 3. Compressor Start Assist Capacitor/Relay Type Start capacitor and start relay gives hard boost to compressor motor at each start-up. SUGGESTED USE: Installations where interconnecting tube length exceeds 50 ft. Installations where outdoor design temperature exceeds 105 F (40.6 C). Replacement installations with hard shutoff expansion valve on indoor coil. 4. Compressor Start Assist PTC Type Solid-state electrical device which gives a soft boost to the compressor at each start-up. SUGGESTED USE: Installations with marginal power supply. Replacement installations with rapid pressure balance (RPB) expansion valve on indoor coil. 5. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control. SUGGESTED USE: When interconnecting tube length exceeds 50 ft. When unit will be operated below 55 F (12.8 C) outdoor air temperature. Use with low-ambient controller. All commercial installations. 6. Cycle Protector Solid-state timing device which prevents compressor rapid recycling. Control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason, including normal room thermostat cycling. SUGGESTED USE: Installations in areas where power interruptions are frequent. Where user is likely to play with the room thermostat. All commercial installations. Installations where interconnecting tube length exceeds 50 ft. High-rise applications. 7. Evaporator Freeze Thermostat An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions. SUGGESTED USE: All units where winter start control has been added. 8. High-Pressure Switch Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to about 400 psig. Provides additional protection against compressor damage due to loss of outdoor airflow. To prevent rapid compressor recycling, cycle protector can be used with this switch. SUGGESTED USE: Installations exposed to very dirty outdoor air. Installations where condenser inlet air temperature exceeds 125 F (51.7 C). 9. Liquid Solenoid Valve (LSV) An electrically operated shutoff valve to be installed at the outdoor or indoor unit (depending on tubing configuration) and which stops and starts refrigerant liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle. Note: Compressor start assist capacitor/relay type must also be used. SUGGESTED USE: For improved system performance in air conditioners for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. In certain long line applications. (Refer to Long-Line Application Guideline.) 6

7 ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) Continued 10. Low-Pressure Switch Auto reset SPST switch activated by refrigerant pressure on low side of refrigerant circuit. Cycles compressor off if refrigerant pressure drops to about 27 psig. Prevents indoor coil freeze-up due to loss of indoor airflow. Also, provides additional protection against compressor damage due to loss of refrigerant charge. To prevent rapid compressor recycling. Cycle protector can be used with this switch. SUGGESTED USE: Where indoor coil is exposed to dirty air. All commercial installations. 11. MotorMaster Control A fan speed control device activated by a temperature sensor. Designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to 20 F, it maintains condensing temperature at 100 F ± 10 F. SUGGESTED USE: operation at outdoor temperatures below 55 F. All commercial installations. 12. Sound Hood Wraparound sound attenuation cover for the compressor. Reduces unit sound level by about 2dBA. SUGGESTED USE: Unit installed closer than 15 ft to quiet areas bedrooms, etc. Unit installed between 2 houses less than 10 ft apart. 13. Thermostatic Expansion Valve (TXV) Kits A modulating flow control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Both hard shutoff and RPB type valves are available. SUGGESTED USE: For improved system performance in cooling mode for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. 14. Time-Delay Relay An SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off. SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. 15. Winter Start Control An SPST delay relay which bypasses the low-pressure switch for approximately 3 minutes to permit start-up for cooling operation under low-load conditions. SUGGESTED USE: All air conditioners where low-ambient controller has been added. 7

8 RATINGS AND PERFORMANCE UNIT SIZE-SERIES 018-C 024-C 030-C 036-C 042-C INDOOR MODEL TOT. CAP. BTUH FACTORY SUPPLIED ENHANCE- MENT STANDARD RATING SEER PAYNE GAS FURNACE OR ACCESSORY TDR ACCESSORY TXV CC5A/CD5AA018* 17,200 NONE CC5A/CD5AA024 17,400 NONE CC5A/CD5AW024 17,400 NONE CE3AA024 17,400 NONE CF5AA024 17,400 NONE CK3BA024 17,400 NONE CK5A/CK5BA018 17,200 NONE CK5A/CK5BA024 17,400 NONE CK5A/CK5BW024 17,400 NONE FF1DNA018 17,200 TDR FF1DNA024 17,400 TDR PF1MNA018 17,200 TDR PF1MNA024 17,400 TDR CC5A/CD5AA024* 22,000 NONE CC5A/CD5AA030 22,400 NONE CC5A/CD5AW024 22,000 NONE CC5A/CD5AW030 22,400 NONE CE3AA024 22,000 NONE CE3AA030 22,400 NONE CF5AA024 22,000 NONE CK3BA024 22,000 NONE CK3BA030 22,400 NONE CK5A/CK5BA024 22,000 NONE CK5A/CK5BA030 22,400 NONE CK5A/CK5BW024 22,000 NONE CK5A/CK5BW030 22,400 NONE FF1DNA024 22,200 TDR FF1DNA030 22,800 TDR PF1MNA024 22,200 TDR PF1MNA030 22,400 TDR CC5A/CD5AA030* 27,600 NONE CC5A/CD5AA036 28,400 NONE CC5A/CD5AW030 27,600 NONE CC5A/CD5AW036 28,400 NONE CE3AA030 27,600 NONE CE3AA036 28,400 NONE CF5AA036 28,400 NONE CK3BA030 27,600 NONE CK3BA036 28,400 NONE CK5A/CK5BA030 27,600 NONE CK5A/CK5BA036 28,400 NONE CK5A/CK5BT036 28,400 NONE CK5A/CK5BW030 27,600 NONE CK5A/CK5BW036 28,400 NONE FF1DNA030 27,600 TDR PF1MNA030 27,600 TDR PF1MNA036 28,400 TDR CC5A/CD5AA036* 33,800 NONE CC5A/CD5AA042 33,800 NONE CC5A/CD5AW036 33,800 NONE CC5A/CD5AW042 33,800 NONE CE3AA036 33,400 NONE CE3AA042 33,600 NONE CF5AA036 33,600 NONE CK3BA036 33,800 NONE CK3BA042 33,800 NONE CK5A/CK5BA036 33,800 NONE CK5A/CK5BA042 33,800 NONE CK5A/CK5BT036 33,800 NONE CK5A/CK5BT042 33,800 NONE CK5A/CK5BW036 33,800 NONE PF1MNA036 33,200 TDR PF1MNA042 33,800 TDR PF1MNA071 35,000 TDR&TXV CC5A/CD5AA042* 40,000 NONE CC5A/CD5AC048 39,500 NONE CC5A/CD5AW042 40,000 NONE CC5A/CD5AW048 40,500 NONE CD5AA048 40,500 NONE EER 8

9 UNIT SIZE-SERIES 042-C 047-C 048-C 060-C INDOOR MODEL RATINGS AND PERFORMANCE Continued TOT. CAP. BTUH FACTORY SUPPLIED ENHANCE- MENT STANDARD RATING * Tested Combination In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Payne furnaces are equipped with TDR. Requires hard shutoff TXV; based on computer simulation. EER Energy Efficiency Ratio SEER Seasonal Energy Efficiency Ratio TDR Time-Delay Relay TXV Thermostatic Expansion Valve N/A Not Applicable NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included. 2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures. 3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan-coil or furnace-coil literature. 4. Minimum outdoor operating ambient in cooling mode is 55 F (12.8 C), maximum 115 F (46.1 C). 5. The dashes ( ) appearing in the SEER WITH ACCESSORY TDR column indicate no improvement in efficiency due to time-delay function built into unit as manufactured (see table). SEER PAYNE GAS FURNACE OR ACCESSORY TDR ACCESSORY TXV CE3AA042 40,000 NONE CE3AA048 40,500 NONE CF5AA048 40,500 NONE CK3BA042 40,000 NONE CK3BA048 40,500 NONE CK5A/CK5BA042 40,000 NONE CK5A/CK5BA048 40,500 NONE CK5A/CK5BT042 40,000 NONE CK5A/CK5BT048 40,500 NONE CK5A/CK5BW048 40,500 NONE PF1MNA042 40,000 TDR PF1MNA048 41,000 TDR PF1MNA071 42,000 TDR&TXV CD5AA048* 44,000 NONE CC5A/CD5AA060 44,000 NONE CC5A/CD5AC048 43,000 NONE CC5A/CD5AW048 44,000 NONE CC5A/CD5AW060 44,500 NONE CE3AA048 44,000 NONE CE3AA060 44,500 NONE CF5AA048 44,000 NONE CK3BA048 44,000 NONE CK3BA060 44,000 NONE CK5A/CK5BA048 44,000 NONE CK5A/CK5BA060 44,000 NONE CK5A/CK5BT048 44,000 NONE CK5A/CK5BT060 44,000 NONE CK5A/CK5BW048 44,000 NONE CK5A/CK5BX060 44,500 NONE PF1MNA048 44,500 TDR PF1MNA060 45,000 TDR PF1MNA070 45,500 TDR PF1MNA071 45,000 TDR&TXV CD5AA048* 45,500 NONE CC5A/CD5AA060 45,500 NONE CC5A/CD5AC048 44,500 NONE CC5A/CD5AW048 45,500 NONE CC5A/CD5AW060 46,000 NONE CE3AA048 45,500 NONE CE3AA060 46,000 NONE CF5AA048 45,500 NONE CK3BA048 45,500 NONE CK3BA060 45,500 NONE CK5A/CK5BA048 45,500 NONE CK5A/CK5BA060 45,500 NONE CK5A/CK5BT048 45,500 NONE CK5A/CK5BT060 45,500 NONE CK5A/CK5BW048 45,500 NONE CK5A/CK5BX060 46,000 NONE PF1MNA048 45,500 TDR PF1MNA060 46,000 TDR PF1MNA070 46,500 TDR PF1MNA071 46,500 TDR&TXV CC5A/CD5AW060* 57,000 NONE CC5A/CD5AA060 56,000 NONE CK5A/CK5BA060 56,000 NONE CK3BA060 56,000 NONE CK5A/CK5BT060 56,000 NONE CK5A/CK5BX060 57,000 NONE CE3AA060 57,000 NONE PF1MNA060 57,500 TDR PF1MNA070 58,000 TDR PF1MNA071 58,000 TDR&TXV EER 9

10 EVAPORATOR CFM EWB DETAILED COOLING CAPACITIES* CONDENSER ENTERING TEMPERATURES F Sens Kw** Sens Kw** Sens Kw** Sens Kw** Sens PA10JA018-C Outdoor Section With CC5A/CD5AA018 Section Kw** Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CC5A/CD5AA CK5A/CK5BA CC5A/CD5AW CK5A/CK5BW CE3AA FF1DNA CF5AA CK3BA PF1MNA PA10JA024-C Outdoor Section With CC5A/CD5AA024 Section Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CC5A/CD5AA CK5A/CK5BA CC5A/CD5AW CK5A/CK5BW CE3AA FF1DNA CF5AA PF1MNA CK3BA See notes on page 13. SOUND POWER (dba) UNIT SOUND OCTAVE BAND CENTER FREQUENCY (Hz) SIZE LEVEL C C C C C C C C

11 EVAPORATOR CFM EWB DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING TEMPERATURES F Sens Kw** Sens Kw** Sens Kw** Sens Kw** Sens PA10JA030-C Outdoor Section With CC5A/CD5AA030 Section Kw** Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CC5A/CD5AA CK5A/CK5BA CC5A/CD5AW CK5A/CK5BT CK5A/CK5BW CE3AA FF1DNA CF5AA PF1MNA CK3BA See notes on page

12 EVAPORATOR CFM EWB DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING TEMPERATURES F Sens Kw** Sens Kw** Sens Kw** Sens Kw** Sens PA10JA036-C Outdoor Section With CC5A/CD5AA036 Section Kw** Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CC5A/CD5AA CK5A/CK5BA CC5A/CD5AW CK5A/CK5BT CE3AA CK5A/CK5BW PF1MNA CF5AA CK3BA PA10JA042-C Outdoor Section With CC5A/CD5AA042 Section Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CD5AA CK5A/CK5BA CC5A/CD5AA CC5A/CD5AC CK5A/CK5BT CC5A/CD5AW CK5A/CK5BW CE3AA PF1MNA CF5AA CK3BA See notes on page

13 EVAPORATOR CFM EWB DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING TEMPERATURES F Sens Kw** Sens Kw** Sens Kw** Sens Kw** Sens PA10JA047-C Outdoor Section With CC5A/CD5AA048 Section Kw** Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CD5AA CK5A/CK5BA CC5A/CD5AA CC5A/CD5AC CK5A/CK5BT CC5A/CD5AW CK5A/CK5BW CE3AA CK5A/CK5BX PF1MNA CF5AA CK3BA PA10JA048-C Outdoor Section With CC5A/CD5AA048 Section Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CD5AA CK5A/CK5BA CC5A/CD5AA CC5A/CD5AC CK5A/CK5BT CC5A/CD5AW CK5A/CK5BW CE3AA CK5A/CK5BX PF1MNA CF5AA CK3BA

14 EVAPORATOR CFM EWB DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING TEMPERATURES F Sens Kw** Sens Kw** Sens Kw** Sens Kw** Sens PA10JA060-C Outdoor Section With CC5A/CD5AA060 Section Kw** Multipliers for Determining the Performance With Other Sections Section Size Power Section Size Power CC5A/CD5AA CK5A/CK5BT CC5A/CD5AW CK5A/CK5BX CE3AA PF1MNA CK3BA CK5A/CK5BA * Detailed cooling capacities are based on indoor and outdoor unit at same elevation per ARI standard 210/ If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. and sensible capacities are net capacities. Blower motor heat has been subtracted. Sensible capacities shown are based on 80 F (27 C) entering air at the indoor coil. For sensible capacities at other than 80 F (27 C), deduct 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80 F (27 C), or add 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air per degree above 80 F (27 C). When the required data falls between the published data, interpolation may be performed. ** Unit kw is total of indoor and outdoor unit kilowatts. 14

15 SYSTEM DESIGN 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc. 2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55 F (12.8 C). 3. Maximum outdoor operating air temperature is 125 F (51.7 C). 4. For reliable operation, unit should be level in all horizontal planes. 5. Maximum elevation of indoor coil above or below base of outdoor unit is: indoor coil above = 50 ft, indoor coil below = 150 ft. 6. For interconnecting refrigerant tube lengths greater than 50 ft, consult Long-Line Application Guideline available from equipment distributor. 7. Crankcase heater required when interconnecting refrigerant tube length exceeds 50 ft. 8. If any refrigerant tubing is buried, provide a minimum 6 in. vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in. may be buried without further consideration. For buried lines longer than 3 ft, consult your local distributor. 9. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided. 15

16 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: SS-PA Payne Heating & P.O. Box 70, Indianapolis, IN 406 PRINTED IN U.S.A. Catalog No. 52PA

563G (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563G.18.1

563G (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563G.18.1 12 SEER ELECTRIC AIR CONDITIONER 563G (60 Hz) Sizes 018 thru 060 Model 563G Energy-Efficient Air Conditioners incorporate innovative technology to provide quiet, reliable cooling performance. Built into

More information

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES AVAILABLE Nominal sizes are available from 018 SIZES: through 060 to meet the needs of residential and light commercial applications. EFFICIENCY: CERTIFICATION: ELECTRICAL RANGE: FAN MOTOR: CABINET: UNIT

More information

563C (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 024 thru 060. Form No. PDS 563C.24.11

563C (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 024 thru 060. Form No. PDS 563C.24.11 12 SEER ELECTRIC AIR CONDITIONER 563C (60 Hz) Sizes 024 thru 060 Model 563C Energy-Efficient Air Conditioners incorporate innovative technology to provide quiet, reliable cooling performance. Built into

More information

10 SEER SPLIT-SYSTEM HEAT PUMP UNIT. Model PH10 SS-PH10-05 FEATURES

10 SEER SPLIT-SYSTEM HEAT PUMP UNIT. Model PH10 SS-PH10-05 FEATURES AVAILABLE Nominal sizes are available from 018 SIZES: through 060 to meet the needs of residential and light commercial applications. EFFICIENCY: CERTIFICATION: With SEER of at least 10.0 and HSPF of 6.8,

More information

563C 12 SEER AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563C.18.5

563C 12 SEER AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563C.18.5 12 SEER AIR CONDITIONER 563C Sizes 018 thru 060 Model 563C Energy-Efficient Air Conditioners incorporate innovative technology to provide quiet, reliable cooling performance. Built into these units are

More information

Product Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES: AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS (018-060) Product Data FEATURES AND BENEFITS AVAILABLE SIZES: Nominal sizes are available from 018 through 060 to meet the needs of residential and light commercial

More information

PAYNE. 710A (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 710A.18.3P. Heating & Cooling

PAYNE. 710A (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 710A.18.3P. Heating & Cooling PAYNE Heating & ELECTRIC CONDITIONER 710A (60 Hz) Sizes 018 thru 060 Model 710A Energy-Efficient Air Conditioners incorporate innovative technology to provide quiet, reliable summer cooling performance.

More information

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES: (60 Hz) 13 SEER Air Conditioner Sizes 018 --- 060 Product Data FEATURES AND BENEFITS AVAILABLE SIZES: Nominal sizes are available from 018 through 060 to meet the needs of residential and light commercial

More information

597C (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 597C.18.8

597C (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 597C.18.8 ELECTRIC AIR CONDITIONER 597C (60 Hz) Sizes 018 thru 060 The Reliant AeroQuiet System (AQS) consists of 3 design features to achieve ultra-low sound ratings. Aerocoustic Design featuring the Aeromax opening

More information

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner. Sizes 018 thru 060 FEATURES

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner. Sizes 018 thru 060 FEATURES Product Data 38CKC (60 Hz) 10 SEER Air Conditioner Sizes 018 thru 060 Model 38CKC Energy-Efficient Air Conditioner incorporates innovative technology to provide reliable summer cooling performance. Built

More information

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( ) (N,P)R SPLIT SYSTEM HEAT PUMP For Use With R --- 22 Refrigerant 1---1/2 TO 5 TONS (018 --- 060) Product Data *Units factory---shipped with no refrigerant. Dry nitrogen charge only. FEATURES AND BENEFITS

More information

Model AA1B 10.0 SEER AIR CONDITIONER SS-AA1B-02. This document was created with FrameMaker FEATURES

Model AA1B 10.0 SEER AIR CONDITIONER SS-AA1B-02. This document was created with FrameMaker FEATURES AVAILABLE SIZES: 18,000 to 60,000 Btu CERTIFICATION: U.L., c-ul, ARI and CEC Listed ELECTRICAL RANGE: 208 230v, 60 Hertz, 1 Phase COMPRESSOR PROTECTION: Each compressor is protected with internal temperature-

More information

Product Data. 38BRC (60 Hz) Air Conditioner. Sizes 024 thru 060 FEATURES/BENEFITS

Product Data. 38BRC (60 Hz) Air Conditioner. Sizes 024 thru 060 FEATURES/BENEFITS Product Data 38BRC (60 Hz) Air Conditioner Sizes 024 thru 060 Model 38BRC Energy-Efficient Air Conditioner incorporates innovative technology to provide quiet, reliable cooling performance. Built into

More information

Product Data. 38EZG (60 Hz) Air Conditioner with Puron. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38EZG (60 Hz) Air Conditioner with Puron. Sizes 018 thru 060 FEATURES/BENEFITS Product Data 38EZG (60 Hz) Air Conditioner with Puron Sizes 018 thru 060 Copyright 2003 Carrier Corporation Model 38EZG Energy-Efficient Air Conditioner incorporates innovative technology to provide quiet,

More information

661C 10 SEER HEAT PUMP UNIT. Sizes 018 thru 060. Form No. PDS 661C FEATURES

661C 10 SEER HEAT PUMP UNIT. Sizes 018 thru 060. Form No. PDS 661C FEATURES 10 SEER HEAT PUMP UNIT 661C Sizes 018 thru 060 The 661C Outdoor Section of Split- Heat Pumps is designed for quiet, reliable heating during the winter and cooling during the summer. With a SEER up to 11.5

More information

697C (60 HZ) Sizes 018 thru 060

697C (60 HZ) Sizes 018 thru 060 SPLIT-SYSTEM HEAT PUMP UNITS 697C (60 HZ) s 018 thru 060 The AeroQuiet System (AQS) consists of 4 design features to achieve ultra-low sound ratings. Aerocoustic Design featuring the Aeromax opening and

More information

Product Data. 38BYG (60 Hz) 12 SEER Heat Pump. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38BYG (60 Hz) 12 SEER Heat Pump. Sizes 018 thru 060 FEATURES/BENEFITS Product Data 38BYG (60 Hz) 12 SEER Heat Pump s 018 thru 060 The 38BYG Outdoor s of Split- Heat Pumps are designed for quiet, reliable heating during the winter and cooling during the summer. With a SEER

More information

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 FEATURES

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 FEATURES Product Data 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS Sizes 018 thru 060 Model 38CKC Energy-Efficient Air Conditioner incorporates innovative technology to provide reliable cooling performance.

More information

Product Data. 38ETG (60 Hz) 13 SEER Air Conditioner with Puron Refrigerant. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38ETG (60 Hz) 13 SEER Air Conditioner with Puron Refrigerant. Sizes 018 thru 060 FEATURES/BENEFITS Product Data 38ETG (60 Hz) 13 SEER Air Conditioner with Puron Refrigerant Sizes 018 thru 060 Model 38ETG Energy-Efficient Air Conditioner incorporates innovative technology to provide quiet, reliable cooling

More information

550A (60 Hz) DELUXE 13 SEER AIR CONDITIONER WITH PURON (R-410A) Sizes 024 thru 060. Form No. PDS 550A.24.4

550A (60 Hz) DELUXE 13 SEER AIR CONDITIONER WITH PURON (R-410A) Sizes 024 thru 060. Form No. PDS 550A.24.4 DELUXE 13 SEER AIR CONDITIONER WITH PURON (R-410A) 550A (60 Hz) Sizes 024 thru 060 Bryant s Quantum Plus 550A with Puron provides a completely unique collection of features which cannot be matched by any

More information

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES Product Data 38CKC 50 Hz Air Conditioner Sizes 018 thru 060 Model 38CKC 50 Hertz energyefficient air conditioner incorporates innovative technology to provide reliable summer cooling performance. Built

More information

Product Data. 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 AVAILABLE OPTIONS

Product Data. 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 AVAILABLE OPTIONS Product Data 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS Sizes 018 thru 060 The 38CKS Air Conditioner is designed for superior performance durability in harsh environments. The product achieves

More information

Product Data PA13NA PA13PA FEATURES AND BENEFITS

Product Data PA13NA PA13PA FEATURES AND BENEFITS PA13NA PA13PA 13 SEER Split---System Air Conditioner With R---410A Refrigerant Single & Three Phase 1 --- 1/2 To 5 Tons Product Data FEATURES AND BENEFITS AVAILABLE SIZES: Nominal sizes are available from

More information

Product Data. 38YCC 50 Hz Heat Pump. Sizes 024 thru 060 FEATURES/BENEFITS

Product Data. 38YCC 50 Hz Heat Pump. Sizes 024 thru 060 FEATURES/BENEFITS Product Data 38YCC 50 Hz Heat Pump Sizes 024 thru 060 The 38YCC 50 Hertz Outdoor s of Split-System Heat Pumps are designed for quiet, reliable heating during the winter and cooling during the summer. With

More information

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES: 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons Product Data The 50 Hertz Outdoor Sections of Split-System Heat Pumps are designed for quiet, reliable heating during the winter

More information

Product Data. 38EYG (60 Hz) 12 SEER Heat Pump with Puron Refrigerant. Sizes 018 thru 060 FEATURES

Product Data. 38EYG (60 Hz) 12 SEER Heat Pump with Puron Refrigerant. Sizes 018 thru 060 FEATURES Product Data 38EYG (60 Hz) 12 SEER Heat Pump with Puron Refrigerant Sizes 018 thru 060 Carrier s technological leadership has risen to a new level with the development of the 38EYG Heat Pump, the outdoor

More information

Product Data. 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes ( /2 to 5 Nominal Tons) FEATURES AND BENEFITS.

Product Data. 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes ( /2 to 5 Nominal Tons) FEATURES AND BENEFITS. (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1 --- 1/2 to 5 Nominal Tons) Product Data The Outdoor Section of Split-System Heat Pumps is designed for quiet, reliable heating during the winter

More information

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton PRODUCT NUMBER NOMENCLATURE 14 SEER Air Conditioner with Refrigerant PA14 N C 018 00G B A Series Variations Electrical Supply N 208/230 60 1 00G Variations C Nominal Capacity 018 1 1/2Ton 024 2Tons 030

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

R4H4. Product Specifications

R4H4. Product Specifications R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on

More information

Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S Baset13 Air Conditioner with Puronr Refrigerant Product Data the environmentally sound refrigerant Carrier s Air Conditioners with Puronr refrigerant provide a collection of features unmatched by any other

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

Product Data. 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060

Product Data. 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060 Product Data 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060 Carrier s WeatherMaker 38TXA with Puron provides a completely unique collection of features which cannot be matched by

More information

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Product Data. 38EYA (60Hz) 12 SEER Split-System Cube Heat Pump with Puron Refrigerant FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT

Product Data. 38EYA (60Hz) 12 SEER Split-System Cube Heat Pump with Puron Refrigerant FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT Product Data 38EYA (60Hz) 12 SEER Split- Cube Heat Pump with Puron Refrigerant Sizes 018 thru 060 FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT Carrier s technological leadership has risen to a

More information

652A DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 018 thru 060. Form No. PDS 652A.18.3

652A DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 018 thru 060. Form No. PDS 652A.18.3 DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT 652A Sizes 018 thru 060 TM The 652A split-system outdoor unit is a 12 SEER heat pump (with efficiencies up to 14.0 SEER). Homeowners will appreciate this

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S BH13NA 018-060 SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT Product Data Bryant s BH13 has been designed utilizing Bryant s refrigerant. The environmentally sound refrigerant allows you to make a responsible

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS Product Data Bryant Air Conditioners with refrigerant provide a collection of features unmatched by any other

More information

Product Data. Performance 14 38TSA (60 Hz) Air Conditioner with Puron Refrigerant. Sizes 024 thru 060 FEATURES

Product Data. Performance 14 38TSA (60 Hz) Air Conditioner with Puron Refrigerant. Sizes 024 thru 060 FEATURES Product Data Performance 14 38TSA (60 Hz) Air Conditioner with Puron Refrigerant Sizes 024 thru 060 Carrier s Performance 14 Air Conditioners with Puron refrigerant provide a collection of features unmatched

More information

WCH5**4. Product Specifications

WCH5**4. Product Specifications HEAT PUMP HIGH EFFICIENCY 15 SEER 1-1/2 THRU 5 TONS SPLIT SYSTEM ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 208 / 230 Volt, 1- phase, 60 Hz This product has been designed and manufactured to meet ENERGY

More information

N4H4. Product Specifications

N4H4. Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase, 208/230 Volt 3- phase, 460 Volt 3- phase; 60 Hz REFRIGERATION CIRCUIT S Scroll compressors

More information

N4A6. Product Specifications

N4A6. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt,

More information

A 14 SEER Heat Pump with R---410A Refrigerant Series

A 14 SEER Heat Pump with R---410A Refrigerant Series MODEL NUMBER NOMENCLATURE PH14 N B 018 00G B A 14 SEER Heat Pump with R---410A Refrigerant Series Electrical Supply N=208/230---1 P=208/230---3 E=460/3 B R---410A Nominal Capacity 018 1 1/2Tons 024 2Tons

More information

650A (60 Hz) QUANTUM PLUS 13 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 024 thru 060. Form No. PDS 650A.24.1

650A (60 Hz) QUANTUM PLUS 13 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 024 thru 060. Form No. PDS 650A.24.1 QUANTUM PLUS 13 SEER HEAT PUMP WITH PURON REFRIGERANT 650A (60 Hz) Sizes 024 thru 060 The Quantum Plus line of split-system outdoor units has been expanded to include the Model 650A 13 SEER heat pump (with

More information

Product Data. Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Product Data. Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060 Product Data Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant Sizes 024 thru 060 Carrier s technological leadership has risen to a new level with the development of the Performance Series

More information

Product Data. Performance 13 38YXA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Product Data. Performance 13 38YXA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060 Product Data Performance 13 38YXA (60 Hz) Heat Pump with Puron Refrigerant Sizes 024 thru 060 Carrier s technological leadership has risen to a new level with the development of the Performance Series

More information

Product Data. Performance 12 38YZA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 018 thru 060

Product Data. Performance 12 38YZA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 018 thru 060 Product Data Performance 12 38YZA (60 Hz) Heat Pump with Puron Refrigerant Sizes 018 thru 060 Carrier s technological leadership has risen to a new level with the development of the Performance Series

More information

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS Product Data Bryant Heat Pumps with Puronr refrigerant provide a collection of features unmatched by any other family

More information

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS 24AHA4 Performance Series Air Conditioner with Refrigerant 1-1/2 to 5 Nominal Tons Product Data Carrier air conditioners with refrigerant provide a collection of features unmatched by any other family

More information

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND REFRIGERANT NH4H4 Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS, 208/230

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons 116B Legacyt Line 16 Air Conditioner with r Refrigerant 1-1/2 to 5 Nominal Tons Product Data Bryant s Air Conditioners with r refrigerant provide a collection of features unmatched by any other family

More information

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS 24ABC6 Comfortt16 Air Conditioner with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data Carrier s Air Conditioners with r refrigerant provide a collection of features unmatched by any other family

More information

Product Data. Efficiency. S S Reliability

Product Data. Efficiency. S S Reliability 018-060 SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT Product Data Bryant s BH14 has been designed utilizing Bryant s refrigerant. The environmentally sound refrigerant allows you to make a responsible

More information

Product Data. Efficiency

Product Data. Efficiency Comfort 13 Heat Pump with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data the environmentally sound refrigerant Carrier heat pumps with r refrigerant provide a collection of features unmatched by

More information

Product Data. Efficiency

Product Data. Efficiency Comfort 13 Heat Pump with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data Carrier heat pumps with r refrigerant provide a collection of features unmatched by any other family of equipment. The 25HCD

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS 114CNC Legacyt Line Air Conditioner for Coastal Applications with r Refrigerant 1--1/2 To 5 Nominal Tons Product Data INDUSTRY LEADING FEATURES / BENEFITS Efficiency S 14.0 SEER / 11.0 13.5 EER S Microtube

More information

Product Data. 38YXA (60Hz) Deluxe 13 SEER Split-System Heat Pump with Puron (R-410A) Refrigerant

Product Data. 38YXA (60Hz) Deluxe 13 SEER Split-System Heat Pump with Puron (R-410A) Refrigerant Product Data 38YXA (60Hz) Deluxe 13 SEER Split- Heat Pump with Puron (R-410A) Refrigerant Sizes 024 thru 060 INTRODUCING THE WEATHERMAKER 38YXA HEAT PUMP FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT

More information

R 410A Ducted Horizontal Air Conditioner

R 410A Ducted Horizontal Air Conditioner ENVIRONMENTALLY SOUND REFRIGERANT HC4A3 Product Specifications R 410A Ducted Horizontal Air Conditioner ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS, 208/230 Volt, 1 Phase 3 THRU 5 TONS, 208/230

More information

HEATING & COOLING 38YCA Sizes 018 thru YCN Sizes 024 thru 048. Copyright 1994 Carrier Corporation

HEATING & COOLING 38YCA Sizes 018 thru YCN Sizes 024 thru 048. Copyright 1994 Carrier Corporation Product Data 38YCA (60 Hz) 38YCN Heat Pump HEATING & COOLING 38YCA s 018 thru 060 38YCN s 024 thru 048 The 38YCA and 38YCN Outdoor s of Split- Heat Pumps are designed for quiet, reliable heating during

More information

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. CA13NA 018 060 Base Series Air Conditioner with r Refrigerant Product Data Carrier s CA13 has been designed utilizing Carrier s non -ozone depleting refrigerant. INDUSTRY LEADING FEATURES / BENEFITS Efficiency

More information

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS. Performancet 16 2 --- Stage Heat Pump with Puronr Refrigerant 2to5Tons Product Data the environmentally sound refrigerant Carrier Air Conditioners with Puron r refrigerant provide a collection of features

More information

Product Data. Efficiency

Product Data. Efficiency 25HCE4**C Comfort 14 Heat Pump for Coastal Applications with r Refrigerant 1---1/5 to 5 Nominal Tons Product Data INDUSTRY LEADING FEATURES / BENEFITS Efficiency S 14 SEER / 11.5 -- 11.7 EER / 8.2 HSPF

More information

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are

More information

R 410A Ducted Horizontal Air Conditioner. Model Number Voltage Size (tons) Nominal Btu/hr Operating Weight lbs (kg) HC4A318AKA

R 410A Ducted Horizontal Air Conditioner. Model Number Voltage Size (tons) Nominal Btu/hr Operating Weight lbs (kg) HC4A318AKA ENVIRONMENTALLY SOUND REFRIGERANT HC4A3 Product Specifications R 410A Ducted Horizontal Air Conditioner ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS, 208/230 Volt, 1 Phase 3 THRU 5 TONS,

More information

Product Data. 38QRR Performancet Series Heat Pump with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 38QRR Performancet Series Heat Pump with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS Performancet Series Heat Pump with Puronr Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data the environmentally sound refrigerant Carrier Heat Pumps with Puronr refrigerant provide a collection of features

More information

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS Product Data FF1DNA, FF1DNE Fan Coil Units Sizes 018 thru 030 FF1D FEATURES/BENEFITS The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air

More information

Product Data. Efficiency

Product Data. Efficiency BH14NB SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 TONS Product Data INDUSTRY LEADING FEATURES / BENEFITS Efficiency S 14 SEER / 11.5-11.7 EER / 8.2 HSPF S Microtube Technologyt refrigeration

More information

Advance Product Data

Advance Product Data Comfort 14 Heat Pump with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Advance Product Data the environmentally sound refrigerant Carrier heat pumps with r refrigerant provide a collection of features unmatched

More information

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. 018---060 Base eries Air Conditioner with r Refrigerant Product Data Carrier s CA13 has been designed utilizing Carrier s refrigerant. The environmentally sound refrigerant allows you to make a responsible

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality

More information

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

Product Data. controls Reliability S Puronr refrigerant - environmentally sound, won t

Product Data. controls Reliability S Puronr refrigerant - environmentally sound, won t Infinityr 15 Heat Pump with Puronr Refrigerant 2to4NominalTons(Sizes24---48) Product Data Carrier s heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

Product Data. Efficiency

Product Data. Efficiency 25HCE4 Comfort 14 Heat Pump with Puronr Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data Carrier heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of

More information

Product Data. S Sound level as low as 67 dba Comfort. S System supports Thermidistatt or standard thermostat controls Reliability

Product Data. S Sound level as low as 67 dba Comfort. S System supports Thermidistatt or standard thermostat controls Reliability 25HPB6 Performancet Series Heat Pump with Puronr Refrigerant 1 --- 1/2 to 5 Tons Product Data the environmentally sound refrigerant Carrier heat pumps with Puronr refrigerant provide a collection of features

More information

INDUSTRY LEADING FEATURES 2 5 / BENEFITS

INDUSTRY LEADING FEATURES 2 5 / BENEFITS Infinityr 19 2 --- Stage Heat Pump with Puronr Refrigerant 2to5NominalTons Product Data Carrier s heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of equipment.

More information

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR: 2 -speed

More information

Installation Instructions

Installation Instructions MODEL LEGACYT ERIE R-22 AIR CONDITIONER IZE 018 TO 060 1-1/2 TO 5 NOMINAL TON Installation Instructions TM INDUTRY LEADING FEATURE / BENEFIT Efficiency ound Comfort Reliability Durability 13 EER / 11.0

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

Product Data. S Up to 20.5 SEER / 15.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound

Product Data. S Up to 20.5 SEER / 15.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound 24VNA0 Infinityr Variable Speed Air Conditioner with Greenspeedr Intelligence 2to5NominalTons Product Data Carrier s 24VNA0 with Greenspeed R Intelligence is a variable speed cooling product providing

More information

Advance Product Data

Advance Product Data EVOLUTION R V VARIABLE SPEED AIR CONDITIONER WITH PURONr REFRIGERANT 2, 3, AND 4-TON (5-TON COMING Q4 2014) Advance Product Data The Evolution V air conditioner offers high -efficiency variable speed performance

More information

Product Data. Model 113A Legacy-RNC Series Air Conditioner with Puronr INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Product Data. Model 113A Legacy-RNC Series Air Conditioner with Puronr INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S Legacy-RNC eries Air Conditioner with Puronr Product Data the environmentally sound refrigerant A05233 Bryant s Air Conditioners with Puronr refrigerant provide a collection of features unmatched by any

More information

Advance Product Data

Advance Product Data Infinityr 19VS Variable Speed Air Conditioner 2, 3, and 4---Ton (5---Ton Coming Q4 2014) Advance Product Data The Infinity 19VS air conditioner offers high -efficiency variable speed performance in a remarkably

More information

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON 7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY

More information

2 shp 13 lc 1 36 t - 1 a

2 shp 13 lc 1 36 t - 1 a HEAT PUMPs 2SHP3 PRODUCT SPECIFICATIONS Dry Charge Split System - 60 HZ Bulletin No. 20645 July 203 Supersedes June 202 3 to 5 Tons MODEL NUMBER IDENTIFICATION 2 shp 3 lc 36 t - a Refrigerant Type 2 =

More information

WJH4 Product Specifications

WJH4 Product Specifications UP TO 14.5 SEER, R 410A PACKAGE HEAT PUMP FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model DS4BD Series M120 Product Line High Efficiency R-410A Air Conditioner 13+ SEER 1.5-5 Ton Capacity 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise

More information

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127. Product Data GEMINI 38AKS028-044 Commercial Air-Cooled Split Systems 50/60 Hz 25 to 40 Nominal Tons (82.8 to 127.0 kw) These dependable split systems match Carrier s indoor-air handlers with outdoor condensing

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS SUNLINE 2000ô MODELS: H5CE090, H3CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 9.0-9.5 EER DESCRIPTION These Sunline 2000ô units are completely

More information

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS AIR CONDITIONERS 13ACXN MERIT Series R-410A Bulletin No. 210831 January 2018 Supersedes Bulletin No. 210739 SEER up to 15.50 1.5 to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh

More information