Air cooled chillers with axial flow fans Cooling capacity from 53 kw up to 150 kw
|
|
- Marlene Nelson
- 6 years ago
- Views:
Transcription
1 NR ir cooled chillers with axial flow fans Cooling capacity from 53 kw up to 150 kw R410 ermec adheres to the UROVNT Certification Programme. The products concerned appear in the UROVNT Certified Products Guide. COMPCT VRSION SINCD COMPCT VRSION IG FFICINCY VRSION SINCD IG FFICINCY VRSION - 2 COOING CIRCUITS - CIRCUTION PUMP - CIRCUTION PUMP ND STORG TNK Characteristics vailable in 9 different sizes Refrigerant R cooling circuits igh efficiency even with partial loads eat exchangers optimised to exploit the excellent heat transfer characteristics of the R410 igh-efficiency scroll compressors xial flow fans with reduced noise level Solid construction with polyester anticorrosion painted finish Cooling mode up to 46 C Versions available: Cooling only compact version ( ) Cooling only compact silenced version ( ) Cooling only, high efficiency ( ) Cooling only, high efficiency, silenced version ( ) C Condensing unit -( ) standard mechanical thermostatic valve up to +4C. - (Y) Mechanical thermostatic valve (low water temperature - down to -6C). - (X) lectronic thermostatic valve also for low water temperature (down to -6C) - Standard and enlarged fans Versions with pumping assembly and tank complete with water filter, flow switch, expansion tank, a charging unit and antifreeze electric heater. Microprocessor control system - Control of the inlet water temperature, with the possibility of selecting the control of the outlet water - Summer condensation control with 0-10V modulating signal depending on pressure, compensated according to the outside air temperature (with DCPX accessory). - Intelligent defrosting with the decrease of the pressure - Rotation of compressors and pumps according to operating hours - Safety capacity control - igh and low pressure transducer, standard on all versions ( for size from 280 to 350 cooling only, TP3 is provided as an accessory) - utomatic reset of alarms before total block - Messages in 4 languages. - istoric alarm ccessories R485: RS-485 interface for supervision systems with MODBUS protocol. VT: anti-vibration support, set of four vibrationdamping components to fit under the sheet metal base of the unit. DCPX: This accessory allows correct operation with outside temperatures below 10C and down to -10C. It is made up of an electronic regulation card that varies the fan rpm on the basis of the condensation pressure, once the high pressure transducer is read for the purposes of keeping it sufficiently high FOR the proper functioning of the unit. It also allows correct heating operation with outside temperatures greater than 30C and up to 42C. DR: Current soft starter device (about 30% reduction for single-circuit-units, 26% for two-circuit-units, 22% for three-circuit-units) Only available for 400V-3-phase power supply. It must be factory set GP: Protection grille, protects the external coil from accidental knocks. PGS: Daily/Weekly Programmer. llows you to programme two time bands per day (two switch on/off cycles) and to have differentiated programming for each day of the week. RIF: Capacitor device. Connected in parallel to the motor winding. It allows to maintain a costant COSδ at 0.95 and also allows an input current reduction (about 10%). It must be factory set when the unit is manufactured. RWB30: The RWB device allows remote control of a chiller via a serial link from a standard PC. Using additional modules, the device allows to control the chiller via the telephone network, using the R- MODM accessory; or via the GSM network, using the RMODMGSM accessory. RWB can pilot up to 9 chillers, but each of these must be equipped with the R485 or R485P2 accessory. TP 3: igh pressure transducer, allows to view the value of the related working pressure (one per circuit), for size from 280 up to 350 cooling only. DUCIR: Simplified control system to switch on and off, and command, two chillers (using ermec GR3 command) in a single system, as if they were a single unit. MUTICIR: Control system to switch the individual chillers on and off, and command them, in a system in which several units are installed in parallel, always ensuring a constant delivery to the evaporators. TRX1: Metal cap that replaces the plastic cap, mounted for protection in the accumulators with holes and supplementary electric heaters. PRM1: FCTORY FITTD CCSSORY. It is a manual pressure switch electrically wired in series with the existing automatic high pressure switch on the compressor discharge pipe.
2 Compatibility of accessories Mod. NR Vers R485 ll DUCIR ll MUTICIR ll PGS ll RWB30 ll TRX1 ll VT (00-P1-P2-P3-P4) VT ( ) (1) DCPX standard standard standard standard standard standard standard standard standard standard DCPX vers. with enlarged fans standard standard standard standard standard standard standard standard standard standard DR ll GP (x2) 2 (x2) 2 (x2) 2 (x2) 2 (x2) (x2) 2 (x2) 2 (x2) 2 (x2) 2 (x3) RIF ll PRM1 ll TP3 ll standard standard standard standard standard NB> The versions available for sizes 280,300,330,350 are only ( - ). Choice of Unit By suitably combining the numerous options available, it is possible to configure each model in such a way as to meet the most particular of system requirements. Field configurator: (1) ccessories DCPX includes: DCPX + TP Code Compressor Model Version Fan Storage tank Size Valve Recovery units Coils Power supply eat thermostat Code: NR Size: 028, 030, 033, 035, 050, 055, 060, 065, 070 Compressors: 0 - R410 standard compressors Thermostatic valve: - Standard mechanical thermostatic valve up to +4C Y - Mechanical thermostatic valve also with processed water down to -6C X - lectronic thermostatic valve also with processed water down to -6C Model: - Cooling only C - Condensing unit eat recovery units - Without recovery units D - With desuperheaters T - With total heat recovery units Version: - Compact - Compact, silenced version - igh efficiency - igh efficiency, silenced version Batteries: - luminium R - Copper S - Tinned copper V - In painted copper and aluminium (epoxy paint) Fans: - Standard M - nlarged ( ) J - Inverter ( ) Power supply: - 400V 3N~ 50z with thermomagnetic switches 1-230V 3~ 50z with thermomagnetic switches 2-500V 3~ 50z with thermomagnetic switches (contact the company head office for versions with DCPX). Storage tank: 00 - without c 01 - low-head storage tank and single pump 02 - low-head storage tank and reserve pump 03 - high-head storage tank and single pump 04 - high-head storage tank and reserve pump 05 - storage tank (with holes for supplementary electric heaters) low-head and single pump 06 - storage tank (with holes for supplementary electric heaters) low-head and reserve pump 07 - storage tank (with holes for supplementary electric heaters) high-head and single pump 08 - storage tank (with holes for supplementary electric heaters) high-head and reserve pump 09 - double hydraulic ring 10 - double hydraulic ring with supplementary electric heater P1 - without storage tank, with low-head pump P2 - without storage tank, with low-head pump and reserve pump P3 - without storage tank, with high-head pump P4 - without storage tank, with high-head pump and reserve pump Warning: options D - T - C are incompatible with option Y; the standard options are shown by the symbol ; the 0350 size is not available with a 500V 3~ 50z power supply; xample of the commercial code: NR This is a size 0350 NR unit with standard mechanical thermostatic valve, cooling only model, compact silenced version, with aluminium condensing coils, standard fans, electrical panel for compressors with 400V 3~ 50z motors and without storage tamk.
3 Technical data Mod. NR Vers. Cooling capacity (kw) Total power input (kw) Water flow rate (l/h) Pressure drop R (W/W) SR (W/W) Power supply Total current input () Maximum current (F) () ll Starting current (R) () ll Type of compressors ll Compressors (no./circuit) Type of fans Fan air flow rate (m³/h) Number of fans (no.) vaporator ll Plumbing connections ll Dimension of plumbing connections (Ø) ll Input power low-head pump (kw) ll Input power high-head pump (kw) ll low-head pump () ll high-head pump () ll Pump useful head low-head cooling mode Pump useful head high-head cooling mode Storage tank capacity ll Sound power db() Sound pressure db() V 3N~ 50z with thermomagnetic switches Scroll /2 3/2 4/2 4/2 4/2 2/2 2/2 2/2 2/2 3/2 3/2 4/2 4/2 4/ /2 3/2 4/2 4/2 4/2 2/2 2/2 2/2 2/2 3/2 3/2 4/2 4/2 4/2 xial Plates Victaulic 2 ½ 2 ½ 2 ½ 2 ½ 2 ½ 2 ½ 2 ½ 2 ½ 2 ½ Performance values refer to the following conditions: Cooling: - water outlet temperature 7 C - outside air temp. 35 C - Δt = 5 C. Sound pressure measured in free field conditions at distance of 10m and direction factor = 2. In accordance with the ISO 3744 standard - Power supply voltage: 400 V
4 Technical data version C Mod. NR C Vers. Cooling capacity (kw) Total power input (kw) R (W/W) Maximum current (F) () ll Starting current (R) () ll () Sound pressure db() Performance values refer to the following conditions: Cooling: - evaporation temperature 5C - outside air temp. 35 C - Δt = 5 C. Sound pressure measured in free field conditions, in cooling mode, at distance of 10m and direction factor = 2. In accordance with the ISO 3744 standard - Power supply voltage: 400 V Dimensions (mm) NR NR C C B B Mod. NR Vers eight (mm) ll Width (mm) B ll Depth (mm) C Weight when empty (kg) NB> The versions available for sizes 280,300,330,350 are only ( - ). Code: SNRUY.04 / 1007 The technical data in this document are not binding. ermec S.p.. shall have the right to introduce at any time whatever modifications deemed necessary for the improvement of the product. ermec S.p.. Via Roma, Bevilacqua (VR) - Italy Telephone Telefax com
5 NR ir cooled chillers with axial flow fans Cooling capacity from 174 kw up to 469 kw R410 ermec adheres to the UROVNT Certification Programme. The products concerned appear in the UROVNT Certified Products Guide. IG FFICINCY VRSION SINCD IG FFICINCY VRSION COMPCT VRSION SINCD COMPCT VRSION - 2 COOING CIRCUITS - CIRCUTION PUMP - CIRCUTION PUMP ND STORG TNK Characteristics vailable in 9 different sizes Refrigerant R cooling circuits igh efficiency even with partial loads eat exchangers optimised to exploit the excellent heat transfer characteristics of the R410 igh-efficiency scroll compressors xial flow fans with reduced noise level Solid construction with polyester anticorrosion painted finish Operating limits with cooling mode up to 46C - Max. processed water temperature 18 C Versions available Cooling only compact version Cooling only compact silenced version Cooling only, high efficiency Cooling only, high efficiency, silenced version C - Condenser unit - lectronic thermostatic valve also for low water temperature (down to -6C) () standard mechanical thermostatic valve (Y) Mechanical thermostatic valve (low water temperature - down to -6C). - nlarged fans Versions with pumping assembly and tank complete with water filter, flow switch, expansion tank, a charging unit and antifreeze electric heater Microprocessor control system - Control of the inlet water temperature, with the possibility of selecting the control of the outlet water - Summer condensation control with 0-10V modulating signal depending on pressure, compensated according to the outside air temperature (with DCPX accessory). - Rotation of compressors and pumps according to operating hours (manual rotation from 1400 to 1800) - Safety capacity control - ow pressure transducers and high pressure trasducer (standard on all the versions) - utomatic reset of alarms before total block - Messages in 4 languages. - larm og ccessories R485: RS-485 interface for supervision systems with MODBUS protocol. VX: Sprung anti-vibration supports. Select the VX model from the compatibility table. DCPX: This accessory allows correct operation with outside temperatures below 10C and down to -10C. It is made up of an electronic regulation card that varies the fan rpm on the basis of the condensation pressure, once the high pressure transducer is read for the purposes of keeping it sufficiently high for the proper functioning of the unit. It also allows correct heating operation with outside temperatures greater than 30C and up to 42C. DR: Current soft starter device (about 30% reduction for single-circuit-units, 26% for two-circuit-units, 22% for three-circuit-units) Only available for 400V-3-phase power supply. It must be factory set. GP: Protection grille, protects the external coil from accidental knocks. PGS: Daily/Weekly Programmer. llows you to programme two time bands per day (two switch on/off cycles) and to have differentiated programming for each day of the week. RIF: Capacitor device. Connected in parallel to the motor winding. It allows to maintain a costant COSδ at 0.95 and also allows an input current reduction (about 10%) It must be factory set when the unit is manufactured RWB30: The RWB device allows remote control of a chiller via a serial link from a standard PC. Using additional modules, the device allows to control the chiller via the telephone network, using the R- MODM accessory; or via the GSM network, using the RMODMGSM accessory. RWB can pilot up to 9 chillers, but each of these must be equipped with the R485 or R485P2 accessory. DUCIR: Simplified control system to switch on and off, and command, two chillers (using ermec GR3 command) in a single system, as if they were a single unit. MUTICIR: Control system to switch the individual chillers on and off, and command them, in a system in which several units are installed in parallel, always ensuring a constant delivery to the evaporators. TRX1: Metal cap that replaces the plastic cap, mounted for protection in the accumulators with holes and supplementary electric heaters. VT: nti-vibration support, to be fitted below the unit base. PRM1 e 2: FCTORY FITTD CCSSORY. It is a manual pressure switch electrically wired in series with the existing automatic high pressure switch on the compressor discharge pipe.
6 Compatibility of accessories Mod. NR Vers R485 ll DUCIR ll MUTICIR ll PGS ll RWB30 ll TRX1 ll VX ll - VT ll DCPX standard standard standard standard standard standard standard standard standard standard standard standard standard standard standard standard standard standard DCPX M vers. standard standard standard standard standard standard standard standard standard with enlarged fans standard standard standard standard standard standard standard standard standard DR ll GP - 10 (x3) 10 (x3) 10 (x3) 10 (x4) 10 (x4) (x3) TP2 ll (x2) (x 2) (x 2) (x 2) (x 2) (x 2) (x 2) (x 2) (x 2) RIF PRM1/PRM2 ll Choice of Unit By suitably combining the numerous options available, it is possible to configure each model in such a way as to meet the most particular of system requirements. Field configurator: Code Compressor Model Version Fan Storage tank Size Valve Recovery units Coils Power supply eat thermostat Code: NR Size: 075, 080, 090, 100, 125, 140, 150, 165, 180 Compressors: 0 - R410 standard compressors Thermostatic valve: - Standard mechanical thermostatic valve up to +4C Y - ow water temperature mechanical thermostatic valve down to -6C X - lectronic thermostatic valve also for low water temperature (down to -6C) Model: - Cooling only C - Condensing unit eat recovery units - Without recovery units D - With partial recovery (desuperheater) T - With total heat recovery (not available in versions with storage tank) Version: - Compact - Compact, silenced version - igh efficiency - igh efficiency, silenced version Batteries: - luminium R - Copper S - Tinned copper V - Varnished Fans: - Standard M - nlarged J - Inverter Power supply: - 400V 3~ 50z with thermomagnetic switches 2-500V 3~ 50z with thermomagnetic switches (contact the company head office for versions with DCPX). Storage tank: 00 - without storage tank 01 - low-head storage tank and single pump 02 - low-head storage tank and reserve pump 03 - high-head storage tank and single pump 04 - high-head storage tank and reserve pump 05 - storage tank (with holes for supplementary electric heaters) low-head and single pump 06 - storage tank (with holes for supplementary electric heaters) low-head and reserve pump 07 - storage tank (with holes for supplementary electric heaters) high-head and single pump 08 - storage tank (with holes for supplementary electric heaters) high-head and reserve pump 09 - double hydraulic ring 10 - double hydraulic ring with supplementary electric heater P1 - without storage tank, with low-head pump P2 - without storage tank, with low-head pump and reserve pump P3 - without storage tank, with high-head pump P4 - without storage tank, with high-head pump and reserve pump Warning: options D - T - C are not compatible with option Y the standard options are shown by the symbol ; the 750 size not available for 500V 3~ 50z alimentation. xample of the commercial code: NR This is a size 090 NR unit with standard mechanical thermostatic valve up to +4C, cooling only model, compact, with aluminium condensing coils, standard fans, electrical panel for compressors with 400V 3~ 50z motors and without storage tank.
7 Technical data Mod. NR Vers Cooling capacity (kw) Total power input (kw) Water flow rate (l/h) Pressure drop R (W/W) SR (W/W) Power supply 400V-3-50z (*) Total input current () Maximum current (F) () Starting current (R) () Type of compressors ll Scroll Compressors (no./circuit) - 4/2 4/2 4/2 4/2 4/2 5/2 6/2 6/2 6/2-4/2 4/2 4/2 4/2 5/2 6/2 6/2 6/2 6/2 Type of fans ll xial Fan air flow rate (m 3 /h) Number of fans (no.) vaporator ll Plates Plumbing connections ll Victaulic Dimension of plumbing connections (Ø) ll 2"1/ Input power low-head pump (kw) ll Input power high-head pump (kw) ll low-head pump () ll high-head pump () ll Pump useful head low-head Pump useful head high-head Storage tank capacity (l) ll ( * ) The power supply for the 075 size is: 400V-3N-50z. Performance values refer to the following conditions: Cooling: - water outlet temperature 7 C - outside air temp. 35 C - Δt = 5 C. Sound pressure measured in free field conditions, in cooling mode at distance of 10m and direction factor = 2. In accordance with the ISO 3744 standard - Power supply voltage: 400 V
8 Mod. NR Vers Sound power db() Sound pressure db() Technical data version C Mod. NR C Vers Cooling capacity (kw) Total power input (kw) R (W/W) Maximum current (F) () Starting current (R) () () Sound power db() Sound pressure db() Dimensions (mm) C C B B The drawings are only examples! Mod. NR Vers eight (mm) C Width (mm) Depth (mm) B Weight when empty (kg) Code: SNRSUY.03 /1007 The technical data in this document are not binding. ermec S.p.. shall have the right to introduce at any time whatever modifications deemed necessary for the improvement of the product. ermec S.p.. Via Roma, Bevilacqua (VR) - Italy Telephone Telefax com
9 NR ir cooled chiller with axial flow fans Cooling capacity from 500 kw up to 938 kw R410 ermec adheres to the UROVNT Certification Programme. The products concerned appear in the UROVNT Certified Products Guide. IG FFICINCY VRSION SINCD IG FFICINCY VRSION COMPCT VRSION SINCD COMPCT VRSION Characteristics vailable in 7 different sizes Refrigerant R cooling circuits igh efficiency even with partial loads eat exchangers optimised to exploit the excellent heat transfer characteristics of the R410 igh-efficiency scroll compressors xial flow fans with reduced noise level Solid construction with polyester anticorrosion painted finish Operating limits with cooling mode up to 46C - Max. processed water temperature 18 C Versions available Cooling only compact version Cooling only compact silenced version Cooling only, high efficiency - 4 COOING CIRCUITS - CIRCUTION PUMP - CIRCUTION PUMP ND STORG TNK Cooling only, high efficiency, silenced version C Condenser unit Thermostatic valve (selectable with configurator): () standard mechanical thermostatic valve (Y) low water temperature mechanical thermostatic valve (down to -6C) (X) electronic thermostatic valve also for low water temperature (down to -6C) Fan unit (selectable with configurator): - Standard. - M nlarged - J Inverter. Versions with pumping assembly and tanks complete with water filter, flow switch, expansion tank, a charging unit and antifreeze electric heater. Microprocessor control system - Control of the inlet water temperature, with the possibility of selecting the control of the outlet water - Summer condensation control with 0-10V modulating signal depending on pressure, compensated according to the outside air temperature (with DCPX accessory). - uto rotation of compressors and pumps according to operating hours - Safety capacity control - ow and high pressure transducers (standard on all the versions) - utomatic reset of alarms before total block - Messages in 4 languages. - larm og ccessories R485P1: RS-485 interface for supervision systems with MODBUS protocol. VX: Sprung anti-vibration supports. Select the VX model from the compatibility table. DCPX: This accessory allows correct operation with outside temperatures below 10C and down to -10C. It is made up of an electronic regulation card that varies the fan rpm on the basis of the condensation pressure, once the high pressure transducer is read for the purposes of keeping it sufficiently high FOR the proper functioning of the unit. It also allows correct heating operation with outside temperatures greater than 30C and up to 42C. GP: Protection grille, protects the external coil from accidental knocks. PGS: Daily/Weekly Programmer. llows you to programme two time bands per day (two switch on/off cycles) and to have differentiated programming for each day of the week. RIF: Capacitor device. Connected in parallel to the motor winding. It allows to maintain a costant COSδ at 0.95 and also allows an input current reduction (about 10%) It must be factory set when the unit is manufactured TRX1: Metal cap that replaces the plastic cap, mounted for protection in the accumulators with holes and supplementary electric heaters. PRM1-PRM2: FCTORY FITTD CCS- SORY. It is a manual pressure switch electrically wired in series with the existing automatic high pressure switch on the compressor discharge pipe.
10 Compatibility of accessories Mod. NR Vers R485P1 ll PGS ll TRX1 ll DCPX standard standard standard standard standard standard standard standard standard standard standard standard standard standard DCPX M vers. standard standard standard standard standard standard standard con ventilatori maggiorati standard standard standard standard standard standard standard GP x x x x x x x x x x 2 RIF RIFNR2800 RIFNR3000 RIFNR3300 RIFNR RIFNR2000 RIFNR2250 RIFNR2500 RIFNR2800 RIFNR3000 RIFNR3300 RIFNR3600 PRM1/PRM2 ll VX (00) VX ( ) VX (P1-P2-P3-P4) Choice of Unit By suitably combining the numerous options available, it is possible to configure each model in such a way as to meet the most particular of system requirements. Field configurator: Code Compressor Model Version Fan Storage tank Size Valve Recovery units Coils Power supply eat thermostat Code: NR Size: 200, 225, 250, 280, 300, 330, 360 Compressors: 0 - R410 standard compressors Thermostatic valve: - Standard mechanical thermostatic valve up to +4C Y - ow water temperature mechanical thermostatic valve down to -6C X - lectronic thermostatic valve also for low water temperature (down to -6C) Model: - Cooling only C - Condensing unit eat recovery units - Without recovery units D - With partial recovery (desuperheater) T - With total heat recovery (not available with storage tank) Version: - Compact - Compact, silenced version - igh efficiency - igh efficiency, silenced version Batteries: - luminium R - Copper S - Tinned copper V - Varnished Fans: - Standard M - nlarged J - Inverter Power supply: - 400V 3~ 50z with thermomagnetic switches 2-500V 3~ 50z with thermomagnetic switches (contact the company head office for versions with DCPX). Storage tank: 00 - without storage tank 01 - low-head storage tank and single pump 02 - low-head storage tank and reserve pump 03 - high-head storage tank and single pump 04 - high-head storage tank and reserve pump 05 - storage tank (with holes for supplementary electric heaters) low-head and single pump 06 - storage tank (with holes for supplementary electric heaters) low-head and reserve pump 07 - storage tank (with holes for supplementary electric heaters) high-head and single pump 08 - storage tank (with holes for supplementary electric heaters) high-head and reserve pump 09 - double hydraulic ring 10 - double hydraulic ring with supplementary electric heater P1 - without storage tank, with low-head pump P2 - without storage tank, with low-head pump and reserve pump P3 - without storage tank, with high-head pump P4 - without storage tank, with high-head pump and reserve pump Warning: options D - T - C are not compatible with option Y the standard options are shown by the symbol ; xample of the commercial code: NR20000 This is a size 200 NR unit with standard mechanical thermostatic valve up to +4C, cooling only model, compact, with aluminium condensing coils, standard fans, electrical panel for compressors with 400V 3~ 50z motors and without storage tank.
11 Technical data Mod. NR Vers Cooling capacity (kw) Total power input (kw) Water flow rate (l/h) Pressure drops R (W/W) SR (W/W) Supply () (ll) 400V-3-50z Type of fan xial Compressors (no.) - 10/4 12/4 12/4 12/4-8/4 8/4 8/4 10/4 12/4 12/4 12/ Total air flow rate (m 3 /h) Operating current () Maximum current (F) () Starting current (R) () Type of compressors Scroll Compressors (no.) - 10/4 12/4 12/4 12/4-8/4 8/4 8/4 10/4 12/4 12/4 12/4 vaporator ll Plates Type of plumbing connections Victaulic Number of plumbing connections Plumbing connections (Ø) / Storage Tank capacity (l) ll 2 x Input power (kw) low-head pump Input power / (kw) high-head pump / / () low-head pump / / () high-head pump / Useful pump head low-head Useful pump head high-head Sound power (db)
12 Mod. NR Vers Sound pressure (db) Mod. NR C Cooling capacity Total power input R Maximum current (F) Starting current (R) Sound pressure (kw) (kw) (W/W) () () () db() Vers / / Performance values refer to the following conditions: Cooling: - water outlet temperature 7 C - outside air temp. 35 C - Δt = 5 C. Sound pressure measured in free field conditions, in cooling mode, at distance of 10m and direction factor = 2. In accordance with the ISO 3744 standard - Power supply voltage: 400 V Dimensions (mm) C B Mod. NR Vers eight (mm) C Width (mm) Depth (mm) B Weight when empty (Kg) The technical data in this document are not binding. ermec S.p.. shall have the right to introduce at any time whatever modifications deemed necessary for the improvement of the product. ermec S.p.. Via Roma, Bevilacqua (VR) - Italy Telephone Telefax com Code: SNRMSUY.03 / 1102
13 NR ir-cooled heat pumps with axial flow fans eating capacity from 58 kw up to 171 kw R410 ermec adheres to the UROVNT Certification Programme. The products concerned appear in the UROVNT Certified Products Guide. COMPCT VRSION SINCD COMPCT VRSION IG FFICINCY VRSION SINCD IG FFICINCY VRSION Characteristics - 2 COOING CIRCUITS - CIRCUTION PUMP - CIRCUTION PUMP ND STORG TNK vailable in 9 different sizes Refrigerant R cooling circuits igh efficiency even with partial loads eat exchangers optimised to exploit the excellent heat transfer characteristics of the R410 igh-efficiency scroll compressors xial flow fans with reduced noise level Solid construction with polyester anticorrosion painted finish xtended operating limits with heat pump functioning: - Max. processed water temperature 55 C - Max. external air temperature 30 C (42 C with speed regulator accessory for the DCPX fans) Cooling mode up to 46 C Versions available: ccessories R485: RS-485 interface for supervision systems with MODBUS protocol. VT: anti-vibration support, set of four vibrationdamping components to fit under the sheet metal base of the unit. DCPX: This accessory allows correct operation with outside temperatures below 10C and down to -10C. It is made up of an electronic regulation card that varies the fan rpm on the basis of the condensation pressure, once the high pressure transducer is read for the purposes of keeping it sufficiently high FOR the proper functioning of the unit. It also allows correct heating operation with outside temperatures greater than 30C and up to 42C. DR: Current soft starter device (about 30% reduction for single-circuit-units, 26% for twocircuit-units, 22% for three-circuit-units). Only available for 400V-3-phase power supply. It must be factory set Can only be installed in the factory. eat pump, compact version eat pump, compact version, silenced version eat pump, high efficiency version. igh-efficiency heat pump, silenced version - nlarged fans Versions with pumping assembly and tank complete with water filter, flow switch, expansion tank, a charging unit and antifreeze electric heater Microprocessor control system - Control of the inlet water temperature, with the possibility of selecting the control of the outlet water - Summer condensation control with 0-10V modulating signal depending on pressure, GP: Protection grille, protects the external coil from accidental knocks. PGS: Daily/Weekly Programmer. llows you to programme two time bands per day (two switch on/off cycles) and to have differentiated programming for each day of the week. RIF: Capacitor device. Connected in parallel to the motor winding. It allows to maintain a costant COSδ at 0.95 and also allows an input current reduction (about 10%). It must be factory set when the unit is manufactured. RWB30: The RWB device allows remote control of a chiller via a serial link from a standard PC. Using additional modules, the device allows to control the chiller via the telephone network, using the R- MODM accessory; or via the GSM network, using the RMODMGSM accessory. RWB can pilot up to 9 chillers, but each compensated according to the outside air temperature (with DCPX accessory). - vaporation control for the heat pump summer operation (with DCPX accessory) - Intelligent defrosting with the decrease of the pressure - Rotation of compressors and pumps according to operating hours - Safety capacity control - igh and low pressure transducer (standard on all versions) - utomatic reset of alarms before total block - Messages in 4 languages. - larm og of these must be equipped with the R485 or R485P2 accessory. DUCIR: Simplified control system to switch on and off, and command, two chillers (using ermec GR3 command) in a single system, as if they were a single unit. MUTICIR: Control system to switch the individual chillers on and off, and command them, in a system in which several units are installed in parallel, always ensuring a constant delivery to the evaporators. TRX1: Metal cap that replaces the plastic cap, mounted for protection in the accumulators with holes and supplementary electric heaters. PRM1: FCTORY FITTD CCSSORY. It is a manual pressure switch electrically wired in series with the existing automatic high pressure switch on the compressor discharge pipe.
14 Compatibility of accessories Mod. NR Vers R485 ll DUCIR ll MUTICIR ll PGS ll RWB30 ll TRX1 ll VT (00-P1-P2-P3-P4) VT ( ) DCPX standard standard standard standard standard standard standard standard standard standard DCPX vers. with enlarged fans ( * ) DR ll (x2) 2 (x2) 2 (x2) 2 (x2) 2 (x2) GP (x2) 2 (x2) 2 (x2) 2 (x2) 2 (x2) (x2) 2 (x2) 2 (x2) 2 (x2) 2 (x3) (x2) 2 (x2) 2 (x2) 2 (x2) 2 (x3) RIF ll PRM1 ll ( * ) DCPX for versions with enlarged fans not necessary (sizes from 500 up to 700). The fans are already equipped with rpm regulator. Choice of Unit By suitably combining the numerous options available, it is possible to configure each model in such a way as to meet the most particular of system requirements. Field configurator: Code Compressor Model Version Fan Storage tank Size Valve Recovery units Coils Power supply eat thermostat Code: NR Size: 028, 030, 033, 035, 050, 055, 060, 065, 070 Compressors: 0 - R410 standard compressors Thermostatic valve: - Standard mechanical thermostatic valve up to +4C X - lectronic thermostat valve for processed water down to -6C Model: - eat pump eat recovery units - Without recovery units D - With partial recovery (desuperheater) T - With total heat recovery units Version: - Compact - Compact, silenced version - igh efficiency - igh efficiency, silenced version igh efficiency, silenced version Batteries: - luminium R - Copper S - Tinned copper V - In painted copper and aluminium (epoxy paint) Fans: - Standard M - nlarged ( ) J - Inverter ( ) Power supply: - 400V 3N~ 50z with thermomagnetic switches 1-230V 3~ 50z with thermomagnetic switches 2-500V 3~ 50z with thermomagnetic switches (contact the company head office for versions with DCPX). Storage tank: 00 - without storage tank 01 - low-head storage tank and single pump 02 - low-head storage tank and reserve pump 03 - high-head storage tank and single pump 04 - high-head storage tank and reserve pump 05 - storage tank (with holes for supplementary electric heaters) low-head and single pump 06 - storage tank (with holes for supplementary electric heaters) low-head and reserve pump 07 - storage tank (with holes for supplementary electric heaters) high-head and single pump 08 - storage tank (with holes for supplementary electric heaters) high-head and reserve pump 09 - double hydraulic ring 10 - double hydraulic ring with supplementary electric heater P1 - without storage tank, with low-head pump P2 - without storage tank, with low-head pump and reserve pump P3 - without storage tank, with high-head pump P4 - without storage tank, with high-head pump and reserve pump Warning: the XD and XT configurations are not available (for temperatures below 4C only); the 0350 size is not available with a 500V 3~ 50z power supply; the standard options are shown by the symbol ; xample of the commercial code: NR This is a size 035 NR unit with standard mechanical thermostatic valve, heat pump model, compact silenced version, with aluminium condensing coils, standard fans, electrical panel for compressors with 400V 3N~ 50z motors and without storage tank.
15 Technical data Mod. NR Vers. Cooling capacity (kw) Total power input (kw) Water flow rate (l/h) Pressure drops R (W/W) SR (W/W) eating capacity (kw) Total power input (kw) Water flow rate (l/h) Pressure drops COP (W/W) Power supply Total current input () Maximum current (F) () ll Starting current (R) () ll Type of compressors ll Compressors (no./circuit) Type of fans ll Fan air flow rate (m³/h) Number of fans (no.) vaporator ll Plumbing connections ll Dimension of plumbing connections (Ø) ll V 3N~ 50z with thermomagnetic switches Scroll /2 3/2 4/2 4/2 4/2 2/2 2/2 2/2 2/2 3/2 3/2 4/2 4/2 4/ /2 3/2 4/2 4/2 4/2 2/2 2/2 2/2 2/2 3/2 3/2 4/2 4/2 4/2 xial Plates Victaulic 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2
16 Mod. NR Vers. Input power low-head pump (kw) ll Input power high-head pump (kw) ll Pump useful head low-head cooling mode Pump useful head high-head cooling mode Storage tank capacity (l) ll Sound power db() Sound pressure db() Performance values refer to the following conditions: Cooling: - water outlet temperature 7 C - outside air temp. 35 C - Δt = 5 C. eating: - water outlet temperature 45 C - outside air temp 7 C D.B. 6 C W.B.; - Δt = 5 C. Sound pressure measured in free field conditions, in cooling mode, at distance of 10m and direction factor = 2. In accordance with the ISO 3744 standard - Power supply voltage: 400 V Dimensions (mm) NR NR C C B B Mod. NR Vers eight (mm) ll Width (mm) B ll Depth (mm) C Weight when empty (kg) NB> The versions available for sizes 280,300,330,350 are only ( - ). Code: SNRUY.05 / 1102 The technical data in this document are not binding. ermec S.p.. shall have the right to introduce at any time whatever modifications deemed necessary for the improvement of the product. ermec S.p.. Via Roma, Bevilacqua (VR) - Italy Telephone Telefax com
17 NR ir cooled heat pumps with axial flow fans eating capacity from 165 up to 523 kw R410 ermec adheres to the UROVNT Certification Programme. The products concerned appear in the UROVNT Certified Products Guide. IG FFICINCY VRSION SINCD IG FFICINCY VRSION COMPCT VRSION SINCD COMPCT VRSION Characteristics vailable in 9 sizes. Refrigerant R Cooling circuits. igh efficiency even with partial loads. eat exchangers optimised to exploit the excellent heat transfer characteristics of the R410. igh-efficiency scroll compressors. xial flow fans with reduced noise level. Solid construction with polyester anti-corrosion painted finish. xtended operating limits with heat pump functioning: - Max. processed water temperature 55 C. - Max. external air temperature 30 C. (42 C with speed regulator accessory for DCPX fans). Versions available: ccessories R485: RS-485 interface for supervision systems with MODBUS protocol. VX: Sprung anti-vibration supports. Select the VX model from the compatibility table. DCPX: With this accessory correct operation is possible with outside temperatures below 10 C and down to 10 C. It is made up of an electronic regulation card that varies the fan rpm on the basis of the condensation pressure, read by the high pressure transducer in order to keep it sufficiently high for the proper functioning of the unit. It also allows correct heating operation with outside temperatures greater than 30C and up to 42C. DR: Current soft starter device (about 30% reduction for single-circuit-units, 26% for two-circuit-units, 22% for three-circuit-units) Only available for 400V-3-phase power supply. It must be factory set. GP: Protection grille, protects external coils from accidental knocks. - 2 COOING CIRCUITS - CIRCUTION PUMP - CIRCUTION PUMP ND STORG TNK - Standard compact heat pump. - Silenced compact heat pump. - igh efficiency heat pump. - igh-efficiency silenced heat pump. Thermostatic valve: - standard mechanical thermostatic valve. - x electronic thermostatic valve, also for low water temperature (down to -6C). Fan unit: - Standard. - J Inverter. Versions with pumping assembly and tank complete with water filter, flow switch, expansion tank, a charging unit and antifreeze electric heater. Microprocessor control system: - Control of the inlet water temperature, with the possibility of selecting PGS: Daily/Weekly Programmer. llows you to programme two time bands per day (two switch on/off cycles) and to have differentiated programming for each day of the week. RIF: Capacitor device. Connected in parallel to the motor winding. It allows to maintain a costant COSδ at 0.95 and also allows an input current reduction (about 10%). It must be factory set when the unit is manufactured. RWB30: the RWB device allows remote control of a chiller via a serial link from a standard PC. Using additional modules, the device allows to control the chiller via the telephone network, using the R- MODM accessory; or via the GSM network, using the RMODMGSM accessory. RWB can pilot up to 9 chillers, but each of these must be equipped with the R485 or R485P2 accessory. the control of the outlet water. - Summer condensation control with 0-10V modulating signal depending on pressure, compensated according to the outside air temperature (with DCPX accessory). - vaporation control for the heat pump summer operation (with DCPX accessory). - Rotation of compressors and pumps according to operating hours (manual rotation from 1400 to 1800). - Safety capacity control. - ow pressure transducers and high pressure transducer (standard for all versions) - utomatic reset of alarms before total block. - Messages in 4 languages. - larm og. DUCIR: Simplified control system to switch on and off, and command, two chillers (using ermec GR3 command) in a single system, as if they were a single unit. MUTICIR: Control system to switch the individual chillers on and off, and command them, in a system in which several units are installed in parallel, always ensuring a constant delivery to the evaporators. TRX1: Metal cap that replaces the plastic cap, mounted for protection in accumulators with holes for supplementary electric heaters. VT: anti-vibration support, to be fitted below the unit base. PRM1-PRM2: FCTORY FITTD CCS- SORY. It is a manual pressure switch electrically wired in series with the existing automatic highpressure switch on the compressor discharge pipe.
18 Compatibility of accessories Mod. NR Vers R485 ll DUCIR ll MUTICIR ll PGS ll RWB30 ll TRX1 ll VX ll - VT ll DCPX standard standard standard standard standard standard standard standard standard standard standard standard standard standard standard standard standard standard DCPX vers. with enlarged fans ll NOT: DCPX not necessary. The fans are already equipped with rpm regulator. DR ll GP - 10 (x3) 10 (x3) 10 (x3) 10 (x4) 10 (x4) (x3) RIF PRM1/PRM2 Tutte Choice of Unit By suitably combining the numerous options available, it is possible to configure each model in such a way as to meet the most particular of system requirements. Field configurator: Code Compressor Model Version Fan Storage tank Size Valve Recovery units Coils Power supply eat thermostat Code: NR Size: 075, 080, 090, 100, 125, 140, 150, 165, 180 Compressors: 0 - R410 standard compressors Thermostatic valve: - Standard mechanical thermostatic valve up to +4C X - lectronic thermostatic valve also for low water temperature (down to -6C) Model: - eat pump eat recovery units - Without recovery units D - With partial recovery (desuperheater) T - With total heat recovery (not available in versions with storage tank) Version: - Standard compact heat pump - Compact heat pump, silenced version - igh efficiency heat pump - igh-efficiency heat pump, silenced version Batteries: - luminium R - Copper S - Tinned copper V - Varnished Power supply: - 400V 3~ 50z with thermomagnetic switches 2-500V 3~ 50z with thermomagnetic switches (contact the company head office for versions with DCPX). Storage tank: 00 - without storage tank 01 - low-head storage tank and single pump 02 - low-head storage tank and reserve pump 03 - high-head storage tank and single pump 04 - high-head storage tank and reserve pump 05 - storage tank (with holes for supplementary electric heaters) low-head and single pump 06 - storage tank (with holes for supplementary electric heaters) low-head and reserve pump 07 - storage tank (with holes for supplementary electric heaters) high-head and single pump 08 - storage tank (with holes for supplementary electric heaters) high-head and reserve pump 09 - double hydraulic ring 10 - double hydraulic ring with supplementary electric heater P1 - without storage tank, with low-head pump P2 - without storage tank, with low-head pump and reserve pump P3 - without storage tank, with high-head pump P4 - without storage tank, with high-head pump and reserve pump Fans: - Standard J - Inverter Warning: the standard options are shown by the symbol ; the XD and XT configurations are not available (for temperatures below 4C only). the 750 size not available for 500V 3~ 50z alimentation. xample of the commercial code: NR This is a size 1000 NR unit with aluminium condensing coils, PD standard evaporator, electrical panel for compressors with 400V 3~ 50z motors and with high-head storage tank and reserve pump. s you may have noticed, each option is represented in a unique way from all the others, so it is not necessary to indicate (within the commercial code) the standard options (identified by ).
19 Technical data Mod. NR Vers Cooling capacity (kw) Total power input (kw) Water flow rate (l/h) Pressure drop R (W/W) SR (W/W) eating capacity (kw) Total power input (kw) Water flow rate (l/h) Pressure drop COP (W/W) Power supply ll 400V-3-50z ( * ) Total input current () Maximum current (F) () Starting current (R) () Type of compressors ll Scroll Compressors / no. circuit (no.) ll 4/2 4/2 4/2 4/2 4/2 5/2 6/2 6/2 6/2 Type of fans ll xial Fan air flow rate (m3/h) Number of fans (n) vaporator ll Plates Plumbing connections ll Victaulic - 3 3" 3" 3" 3" 4" 4" 4" 4" Dimension of plumbing connections (Ø) - 3 3" 3" 3" 4" 4" 4" 4" 4" Input power low-head pump (kw) ll Input power high-head pump (kw) ll low-head pump () ll high-head pump () ll Pump useful head low-head cooling mode Pump useful head high-head cooling mode Tank capacity (l) ll ( * ) The power supply for the 075 size is: 400V-3N-50z.
20 Mod. NR Vers Sound power db() Sound pressure db() Performance values refer to the following conditions: Cooling: - water outlet temperature 7 C - outside air temp. 35 C - Δt = 5 C. Dimensions (mm) eating: - water outlet temperature 45 C - outside air temp 7 C D.B. 6 C W.B.; - Δt = 5 C. Sound pressure measured in free field conditions, in cooling mode, at distance of 10m and direction factor = 2. In accordance with the ISO 3744 standard - Power supply voltage: 400 V C C B B The drawings are only examples! Mod. NR Vers eight (mm) C Width (mm) Depth (mm) B Weight when empty (kg) Warning: the weights refer to versions without storage tank and pump. Selection VX Mod. NR Vers. VX NR NR NR800 - P1-P2-P3-P4 703 NR NR NR800 - P1-P2-P3-P4 706 NR NR NR900 - P1-P2-P3-P4 709 NR NR NR900 - P1-P2-P3-P4 712 NR NR NR P1-P2-P3-P4 715 NR NR NR P1-P2-P3-P4 712 NR NR NR P1-P2-P3-P4 718 NR NR NR P1-P2-P3-P4 721 The technical data in this document are not binding. ermec S.p.. shall have the right to introduce at any time whatever modifications deemed necessary for the improvement of the product. ermec S.p.. Via Roma, Bevilacqua (VR) - Italy Telephone Telefax com Mod. NR Vers. VX NR NR NR P1-P2-P3-P4 724 NR NR NR P1-P2-P3-P4 724 NR NR NR P1-P2-P3-P4 729 NR NR NR P1-P2-P3-P4 732 NR NR NR P1-P2-P3-P4 729 NR NR NR P1-P2-P3-P4 736 NR NR NR P1-P2-P3-P4 732 NR NR NR P1-P2-P3-P4 736 Code: SNRSUY.03 / 1007
21 NR ir cooled heat pumps with axial flow fans eating capacity from 462 up to 944 kw R410 ermec adheres to the UROVNT Certification Programme. The products concerned appear in the UROVNT Certified Products Guide. IG FFICINCY VRSION SINCD IG FFICINCY VRSION COMPCT VRSION SINCD COMPCT VRSION Characteristics - 4 COOING CIRCUITS - CIRCUTION PUMP - CIRCUTION PUMP STORG TNK vailable in 7 sizes. Refrigerant R Cooling circuits. igh efficiency even with partial loads. eat exchangers optimised to exploit the excellent heat transfer characteristics of the R410. igh-efficiency scroll compressors. xial flow fans with reduced noise level. Solid construction with polyester anticorrosion painted finish. xtended operating limits with heat pump functioning: - Max. processed water temperature 55 C. - Max. external air temperature 30 C. (42 C with speed regulator accessory for DCPX fans). Versions available: - Standard compact heat pump. - Silenced compact heat pump. - igh efficiency heat pump. ccessories R485P1: RS-485 interface for supervision systems with MODBUS protocol. VX: Sprung anti-vibration supports. Select the VX model from the compatibility table. DCPX: With this accessory correct operation is possible with outside temperatures below 10 C and down to 10 C. It is made up of an electronic regulation card that varies the fan rpm on the basis of the condensation pressure, read by the high pressure transducer in order to keep it sufficiently high for the proper functioning of the unit. It also allows correct heating operation with outside temperatures greater than 30C and up to 42C. - igh-efficiency silenced heat pump. Thermostatic valve (selectable with configurator): - standard mechanical thermostatic valve. - x electronic thermostatic valve, also for low water temperature (down to -6C). Fan unit (selectable with configurator): - Standard. - M nlarged. - J Inverter. Versions with pumping assembly and tanks complete with water filter, flow switch, expansion tank, a charging unit and antifreeze electric heater. Microprocessor control system: - Control of the inlet water temperature, with the possibility of selecting the control of the outlet water. - Summer condensation control with 0-10V modulating signal depending on GP: Protection grille, protects external coils from accidental knocks. PGS: Daily/Weekly Programmer. llows you to programme two time bands per day (two switch on/off cycles) and to have differentiated programming for each day of the week. RIF: Capacitor device. Connected in parallel to the motor winding. It allows to maintain a costant COSδ at 0.95 and also allows an input current reduction (about 10%) It must be factory set when the unit is manufactured. TRX1: Metal cap that replaces the plastic cap, pressure, compensated according to the outside air temperature (with DCPX accessory). - vaporation control for the heat pump summer operation (with DCPX accessory). - uto rotation of compressors and pumps according to operating hours (for all sizes) - Safety capacity control. - ow and high pressure transducers (standard for all versions). - utomatic reset of alarms before total block. - Messages in 4 languages. - larm og. mounted for protection in accumulators with holes and supplementary electric heaters. PRM1-PRM2: FCTORY FITTD CCS- SORY. It is a manual pressure switch electrically wired in series with the existing automatic high pressure switch on the compressor discharge pipe.
Construction details: Structure and base in hot dip galvanised sheet steel with epoxy pain finish (RAL 9002)
Water cooled internal chiller and heat pump units with scroll compressors Cooling capacity from 106 kw to 385 kw NXW Heating capacity from 119 kw to 419 kw R410A Aermec participates in the EUROVENTProgram:
More informationNRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER
NRP MULTIPURPOSE HEAT PUMPS AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER Multipurpose air cooled units with axial fans. For external installation. High efficiency version. NRP MULTIPURPOSE
More informationCMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N
E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,
More informationLSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES
LS ir cooled water chillers with axial fans + LS The LS water chiller range has been designed for small and medium residential and commercial applications. They are suitable for generating chilled water
More informationLER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS
Indoor motor-driven evaporating units LER 0-0 kw Compact and silent machines with remote dissipation into the air Scroll compressor PLUS R-0A R-0A refrigerant Cooling only Split version Electronic expansion
More informationCMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL
CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years
More informationTOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS
TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS Energy saving thanks to a total recovery p Cooling Heating/DHW h Galletti multi-purpose heat pumps are total recovery units used for a simultaneous hot and
More informationpyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning
Comfort PYXIS HP U : ir / water reversible heat pumps for outdoor installation, equipped with scroll compressors and axial fans Cooling Capacity: 42,3 195,0 Heating Capacity: 47,1 222,0 NEW IDE R410 rcgroupairconditioning
More informationSMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB
T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING
More informationLZA High efficiency air to water heat pumps with HP compressor
High efficiency air to water heat pumps with HP compressor -10 C +43 C +60 C HP C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems
More informationLCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS
Total heat recovery multi-purpose units LCP Outdoor monobloc air-water unit LCP - kw Heating, cooling, domestic hot water one single system to meet all kinds of needs. Total heat recovery multi-purpose
More informationAWR MTD2 XE. Versions
Versions ETING COOLING OT WTER ETING COOLING OT WTER ir/water reversible heat pump for water heating up to 58 C and operating limits down to -15 C external air temperature and domestic hot water production.
More informationAIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS
RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly
More informationKälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10
Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW Compressors Scroll Serie: Series: Emissione: Issue: SCAEY Catalogo: Leaflet: Sostituisce: Supersedes: DE 88 04/11 12/10 Index
More informationLEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS
Total heat recovery multi-purpose units LEP Indoor monobloc water-water unit LEP 50-40 kw Maximum efficiency with total recovery and dissipation in water. Total heat recovery multi-purpose unit Multi-purpose
More informationAIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES
AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES COOLING CAPACITY FROM 76 TO 612 Kw 1 AND 2 COOLING CIRCUITS RAE 1702 F Kc + P2 28 Above picture is only indicative
More informationLZT High efficiency air to water heat pumps with E.V.I. compressors
High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating
More informationKälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98
Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw Scroll Compressors Series: SCAEY-FC Leaflet: DE 98 Issue: 01/16 Supersedes: 12/13 Identification code Index Index... pag. 2 Identification code...»
More informationpyxis pyxisa NEW rcgroupairconditioning
Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 119,0 808,0 PLTE C rcgroupairconditioning
More informationHIWARM COMPACT kw
Total heat recovery multi-purpose s HIWRM COMPCT Outdoor monobloc air-water with BLDC compressor HIWRM COMPCT - kw Total recovery and energy efficiency in every condition Total heat recovery multi-purpose
More informationAir Cooled Chillers & Heat Pumps WinPACK HE-A
Air Cooled Chillers & Heat Pumps WinPACK HE-A TCAEY-THAEY 2110-4340 1 Air Cooled Chillers & Heat Pumps WinPACK HE-A TCAEY-THAEY 2110-4340 Cooling capacity: 91,6-345 kw Heating capacity: 110,5-357 kw Class
More informationpyxis u pyxis ua NEW rcgroupairconditioning
Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44,9 200,0 rcgroupairconditioning R410 C PLTE
More informationGPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1
UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A
More informationMPE 4-76 kw. Outdoor monobloc unit. Air chillers and heat pumps MPE PLUS. Efficiency under all operating conditions. 152 galletti.
Air chillers and heat pumps MPE Outdoor monobloc unit MPE - kw Efficiency under all operating conditions Rotary compressor PLUS Scroll compressor R-0A R-0A refrigerant Cooling only Cooling / Heating Monobloc
More informationpyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning
Industrial PYXIS CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with scroll compressor and microchannel condensing coils Cooling Capacity: 108 876
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are
More informationBRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.
More information
Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw
Air cooled chillers with brushless oil-free compressors R-134a RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw External installation with very low sound level Cooling circuit with
More informationRAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR
AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 46 Above picture is only indicative and is not binding AIR FC The packaged air cooled chillers of RAS Kp series are suitable
More informationRAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS
AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.
More informationRC GROUP. MULTIPLO.A.STD/ELN G Multifunctions air cooled liquid chillers with Scroll compressors and axial fans R407C. SCROLL compressors kw
MULTIPLO..STD/LN G Multifunctions air cooled liquid chillers with Scroll compressors and axial fans SCROLL compressors 60 110 kw RC GROUP TCHNICL DOCUMNTTION MLTSRL_G_GB407_0203 MULTIPLO..STD/LN G Multifunctions
More informationPRODUCT GUIDE
PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency
More information> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories
> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base
More informationБольшая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.
Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive,
More informationCZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or
More informationCZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with
More informationWDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES
Ground source heat pumps +60 C C.O.P. 5,1 heat pumps are particularly suitable for applications that utilise ground source probes.these units have been designed for use with radiant floor heating systems
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are
More informationPYXIS U PYXIS U. rcgroupairconditioning
Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44 284 rcgroupairconditioning MIN FETURES
More informationSLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual
u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications
More information1
ST www.coldinnovation.it 1 INDEX Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R410A...pag. 5 Scroll compressors...pag. 6 Condenser
More informationWHA WHA. Ground source heat pumps OTHER VERSIONS ACCESSORIES
Ground source heat pumps +60 C C.O.P. 5,1 heat pumps are particularly suitable for applications that utilise ground source probes.these units have been designed for use with radiant floor heating systems
More informationTECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE
GB TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE 5 kw - 213 kw TABLE OF CONTENTS 1 The series...4 2 Constructive features...4 3 Layout of components...5 4 Models and configurations...13 5 Technical
More informationO L R E RGA ST RA N AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION TECHNICAL MANUAL
-FRIEND A R E IG RA N T G RGA ST RE F S Y E O L C AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION TECHNICAL MANUAL 1 2 SUMMARY THIS MANUAL IS DIVIDED INTO SECTIONS. THEIR NAMES APPEAR IN THE
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationКомпрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.
1 Компрессорно-конденсаторные агрегаты Chiller AQH DCI 20 to 30 Air Cooled Water Inverter Heat ump Engineering Data Manual 20 to 30 kw 20 to 30 kw Specifications 3 AQH DCI Finned coil optimized in ing
More informationKälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98
Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw Scroll Compressors Series: SCAEY-FC Leaflet: DE 98 Issue: 04/11 Supersedes: 12/10 Identification code Index Index... pag. 2 Identification code...»
More informationWZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors
High Efficiency ir to Water Split System Heat Pumps With E.V.I. ompressors -20 +43 +65 HP E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor
More informationLSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES
Air to water chillers and heat pumps The water chillers range have been designed for small and medium residential and commercial applications. The water chillers are suitable for water outlet temperatures
More informationLZT High efficiency air to water heat pumps with E.V.I. compressors
High efficiency air to water heat pumps with E.V.I. compressors -20 +43 +65 E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems
More informationGEYSER kw. General information. Unique selling points
6 78 kw General information Dedicated heat pumps new series with Scroll compressors, with and without vapor injection. /HT version in 15 sizes Cooling capacity (35;W7): 6 73 KW Heating capacity (7;W45):
More informationGLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning
: Packaged air cooled liquid chillers with free-cooling system for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 314 1343 Free-Cooling Capacity: 308 938 GLYCOL
More informationMulti-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw
Multi-pipe Units with Scroll Compressors Model CMAA Cooling capacity 45-485 kw Heating capacity 50-670 kw CMAA multi-pipe units Simultaneous heating and cooling with one product Standard versions Acoustic
More informationCRIMSON & CRIMSON MAX
High efficiency water/water and geothermal heat pumps 5 114 General High efficiency water/water and geothermal heat pumps. Ideal for heating, cooling and production of domestic hotwater with total or partial
More informationLDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES
Air to water chillers and heat pumps The water chillers range is an efficient and low-noise product designed for medium to big applications. The water chillers are suitable for water outlet temperatures
More informationEASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB
R407C EASY_R Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans 5,2 41,5 kw T_ESY_R_0508_GB EASY_R R407C INDEX WORKING LIMITS... 3 SERIES IDENTIFICATION... 4 MODEL
More informationAQUASNAP JUNIOR 30RHV
High-Efficiency Air-To-Water Heat Pumps Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. AQUASNAP JUNIOR 3RHV 6-11
More informationHYDRONIC RESIDENTIAL
HYDRONIC RESIDENTIAL Chillers, reversible heat pumps and modular units for small and medium applications. Climaveneta. brand of Mitsubishi Electric Hydronics & IT Cooling Systems, presents the mini chiller
More informationMPI DC 8-29 kw. Outdoor monobloc unit with BLDC compressor. Air chillers and heat pumps MPI DC PLUS
Air chillers and heat pumps MPI DC Outdoor monobloc unit with BLDC compressor MPI DC - 9 kw Large operating range and energy efficiency under every condition BLDC scroll compressor PLUS BLDC rotary compressor
More informationRTA TECHNICAL MANUAL AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L S E A F RA N
A RE F S E -FRIEND Y R E IG RA N T G AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L RTA C TECHNICAL MANUAL 1 2 SUMMARY THIS MANUAL IS DIVIDED INTO SECTIONS. THEIR NAMES APPEAR IN THE HEADING
More informationSA 1 INDEX Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R410A...pag. 5 Scroll compressors...pag. 6 Condenser coils...pag. 6 Brazed
More informationGLIDER EVO GLIDER EVO. rcgroupairconditioning
: Packaged air cooled liquid chillers for outdoor installation equipped with screw compressors and axial fans Cooling Capacity: 300 1313 rcgroupairconditioning R134a SHELL C MIN FETURES ir cooled liquid
More informationWZH Ground source heat pumps
Ground source heat pumps infolinia: +48 691 262 691 +60 C C.O.P. 5,1 HP heat pumps are particularly suitable for applications that utilise well water or ground source probes. These units have been designed
More informationH4T R410A. refrigerant
H4T INDEX Polyvalent unit working modes...pag. 4 Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R410A...pag. 5 Scroll compressors...pag.
More informationB. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).
Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage
More informationAir Cooled Chillers & Heat Pumps FullPower HE-A
Air Cooled Chillers & Heat Pumps FullPower HE-A TCAVTZ-TCAVQZ 345-1335 1 Air Cooled Chillers & Heat Pumps FullPOWER HE-A TCAVTZ-TCAVQZ 345-1335 Cooling capacity: 317-1.35 Efficient range in class A Extended
More informationMotor-driven condensing units MTE MTE R-410A
Motor-driven condensing units MTE Outdoor motor-driven condensing units MTE - 0 kw Efficiency and compactness for commercial air conditioning Scroll compressor PLUS R-0A R-0A refrigerant Cooling only Split
More informationDunham Bush Air Cooled Screw Chiller AFVX B 6SR Series
Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR
More informationGLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning
GLIDER EVO CL GLIDER EVO CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 282 1513 HIGHEFFICIENCY
More informationEpsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points
Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique
More informationWHA WHA. Ground source water to water heat pumps A ++ A ++ Versions
WH ++ ++ +60 82 WH Ground source water to water heat pumps WH heat pumps are particularly suitable for applications that utilise ground source probes.these units have been designed for use with radiant
More informationglider evo cla glider evo cla A-CLASS rcgroupairconditioning
Industrial GLIDER EVO CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 284 1513 -CLSS rcgroupairconditioning
More informationCHAPTER 6 CONDENSING UNITS
CHAPTER CONDENSING UNITS Unit Page MHA/K - MHA/K 8 0 - MRA/K 8-9 MRA/K 8 0 0 - FROM, KW TO KW. MHA/K AIRCOOLED CONDENSING UNITS AND REVERSIBLE CONDENSING UNITS WITH AXIAL FANS AND ROTARY/SCROLL COMPRESSOR.
More informationunico pf unico pf rcgroupairconditioning
: ckaged air cooled liquid chillers for indoor installation, equipped with scroll compressors and plug fan Cooling Capacity: 19,6 264 unico pf PLTE rcgroupairconditioning R410 E C MIN FETURES ir cooled
More informationWATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ
WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5
More informationSPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw
SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:
More informationi-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:
ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within
More informationHIWARM kw. Air-water system with external and internal BLDC unit. Total heat recovery multi-purpose units HIWARM PLUS
Total heat recovery multi-purpose units HIWARM Air-water system with external and internal BLDC unit HIWARM - kw The perfect combination between multi-purpose, inverter technology and style Multi-purpose
More informationGalletti Water chillers and heat pumps catalogue
Galletti www.galletti.it Water chillers and heat pumps catalogue Table of Contents/SMALL SYSTEMS MPI DC Water chillers and heat pumps with inverter compressor 6 models page 6 MCE MPE Air condensed water
More informationSPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module
SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:
More informationLZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors -15 +63 E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems
More informationGeolo THE GROUND SOURCE HEAT PUMP PLUSES
Geolo THE GROUND SOURCE HEAT PUMP PLUSES RENEWABLE TECHNOLOGIES Geolo is able to exploit the Energy present in the water and underground thanks to the geothermal exchangers. Soil and water absorb the solar
More informationunico turbo fl kw R134a MICRO CHANNEL OIL FREE INVERTER FLOODED CLASS E C Energy Class RCGROUP SpA fiftycoolyears C_GNR_0113
tu 137 IR COOLED Liquid chiller equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded evaporator and microchannel CONDENSING coils 280 1500 kw Energy Class More efficient
More informationAquaflair TRAC-TRAF-TRAH
Aquaflair TRAC-TRAF-TRAH 110 400 kw Air-cooled chillers, free-cooling chillers and heat pumps for mission critical applications Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors
More informationHeat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications
Heat Pump Technology Air Source, Water Source and Ground Source Optimised heat pumps for residential and commercial applications ICS Cool Energy Limited has nearly 25 years experience in supplying and
More information30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +
Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG + Quality Management Systems 30RBY/RQY 017-033 Nominal cooling capacity 15-33 kw Nominal heating capacity 17-31 kw The new
More informationBRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01
b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a
More informationBRAN. Climaveneta Technical Bulletin BRAN_0011_0121_201211_EN ,6-31,3 kw. Reversible unit, air source for outdoor installation
Climaveneta Technical Bulletin BRAN_0011_0121_201211_EN BRAN r HFC R-410A 0011-0121 4,6-31,3 kw Reversible unit, air source for outdoor installation (The photo of the unit is indicative and may change
More informationKälte Klima. Water cooled water chillers from 200 kw to 1550 kw. Screw Compressor LCWX DE 56 01/16 12/13
Water cooled water chillers from 200 kw to 1550 kw Screw Compressor Serie: Series: Emissione: Issue: LCWX Catalogo: Leaflet: Sostituisce: Supersedes: DE 56 01/16 12/13 Index Identification code Index...
More informationnemo a hp rcgroupairconditioning R410A
NEMO A HP: Motoevaporating heat pumps for indoor installation, equipped with scroll compressor and plate heat exchanger Cooling Capacity: 5,5 25,0 Heating Capacity: 6,4 29,3 nemo a hp PLATE rcgroupairconditioning
More informationTechnical Manual NXW WATER COOLED CHILLER AND HEAT PUMP INDOOR UNITS SCROLL COMPRESSORS INXWPY _01
Technical Manual WATER COOED CHIER AND HEAT PUMP INDOOR UNITS SCRO COMPRESSORS NXW EN INXWPY. 14.2. 4438856_1 Dear customer, Thank you for choosing AERMEC. It is the fruit of many years of experience and
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More informationRMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL
RMA ECO-FRIENDLY REFRIGERANT GAS AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the
More informationintarpack intarpack axial MDE / BDE series air-cooled condensing units High power in the smallest space. Tropicalised design for ambient temperature
aircooled condensing units intarpack intarpack aircooled compact refrigeration plants have been designed for outdoor installation, with minimum space needs. intarpack range covers compressor from 8 to
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More informationAIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw
COMFORT HEAT PUMPS AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw climaveneta.com COMFORT HEAT PUMPS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air to water heat pump for outdoor installation,
More informationCIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet
Attractive design, Compact and quiet Many customisable configurations possible For indoor installation New reliable technologies Version with Plug and Cool hydraulic module Cooling capacity: 23 to 140
More informationAQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual
u Air-to-Water Reverse Cycle Heat Pumps AQH 40 to 130 40 to 131 kw 45 to 141 kw Engineering Data Manual EDM AQH-W.3GB Date : November 2007 Supersedes : TM AQH-W.2GB/03.04 Specifications The Aqu@Logic air-to-water
More informationMULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw
Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01
More informationZeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017
Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air
More information