1 1 Welcome to our Training Centre

2 2 Green Gateway Initiative The Green Gateway Initiative is a bold and ambitious 10-point plan that points the way to a reduction of over 3 million tonnes of CO2 per year, by That s the equivalent of removing 830,000 cars from the UK s roads. The Stern Report has highlighted the catastrophic danger to businesses of ignoring climate change and we need to recognise that this is a challenge that involves us all. If we are to meet this challenge and get anywhere near the targets for emissions reductions that the Government has set then we need to look at more energy efficient ways of providing the comfort levels for our buildings that modern life (and increasing legislation) demands. Anyone involved in this industry- architects, developers, consultants, building services specifiers, installers, and equipment manufacturers, needs to find ways to provide modern, comfortable internal environments, in the most energy efficient and sustainable way possible.

3 3 Low Carbon Domestic Space and Water Heating Design and Installation

4 4 Subjects Covered CO 2 Reduction Targets What is The Ecodan Heat pump System Operations Design and Application Service and Maintenance Regulations and Legislation

5 5 CO 2 Emission Reduction How important is it? Energy saving Cost savings Legal requirement Moral obligation

6 6 Domestic CO 2 Emissions A major cause of climate change comes from the energy we use to heat, light and run our homes The domestic sector is a critical area and is responsible for 27% of UK CO 2 emissions Energy demand in the sector grew 17.5% from 1990 to 2003 All fossil fuels are finite resources and need to be used as economically as possible. Source: DTI 2002, DEFRA 2002

7 7 The Code for Sustainable Homes Minimum standards for energy usage Current Building Regulations CO 2 emission = Level 0 Target Emissions Rate Reduction in CO 2 from current building regulations (TER) Level 1 * -10% Level 2 ** -18% Level 3 *** -25% by 2010 Level 4 **** -44% by 2013 Level 5 1 ***** -100% Level 6 2 ****** Zero Carbon by Zero emissions in relation to Building Regulations issues (i.e. zero emissions from heating, hot water, ventilation and lighting). 2. A completely zero carbon home (i.e. zero net emissions of carbon dioxide (CO 2 ) from all energy use in the home).

8 8 C0 2 Emission Levels Fuel Type Kg CO 2 per kwh Boiler Efficiency Kg CO 2 per kwh of useful heat Coal % 0.40 Oil % 0.31 LPG % 0.26 Gas % 0.20 Electricity % 0.17 Typical Efficiencies Coal Boiler 50 to 85% Oil Boiler 50 to 90% LPG Boiler 80 to 95% Gas Boiler 80 to 95% Heat Pump 250 to 500% Worst case heat pump vs. Best case boiler

9 9 The Ecodan Heat Pump

10 10 The Ecodan Heat Pump! What is a Heat Pump? Benefits of a Heat Pump The Ecodan Packages

11 11 The Heat Pump System A heat pump harvests low grade heat energy for free and delivers it where it is useful The heat is upgraded using the vapour compression cycle As the main heat source is free, the efficiency is excellent ~300% to 400% annually

12 12 The Magic of a Heat Pump! Low temperature renewable heat energy recovered from the environment Energy from the ambient air 2kW High temperature heat output Electrical power in 1kW 3kW

13 13 The Vapour Compression Cycle: Heating Low pressure saturated liquid and vapour Expansion Valve - throttling Evaporator Compressor Low pressure superheated vapour 4 way valve Condenser Plate Heat Exchanger High pressure high temp superheated vapour

14 14 Benefits of the Ecodan HP High CoPs (Coefficients of Performance) Reduced Carbon emissions Reduced Energy Consumption Reduced Running costs Electricity can be from Renewable Sources No Gas Supply or Fuel Tank needed

15 15 Coefficients of Performance (COP) Coefficients of performance relate the useful heat output to the electrical energy consumed COP = Heating output Power consumed

16 16 Performance Factors The unit harvests and upgrades free heat energy. Therefore the amount of heat delivered is always greater than the energy paid for. COPs in the region of 3.0 to 4.0 are achievable i.e. for every kw of electrical energy consumed 3.0 to 4.0 kw of heat energy can be delivered.

17 17 Performance Factors: COP at varying conditions Increase in condensing temperature and decrease in evaporating temperature reduce COP. C amb Water temp ºC Inlet/outlet 30/35 40/45 50/ (1.37) *Figures for 8.5 KW heat pump ( ) T ambient C

18 18 Weather Compensation The weather compensation works in two ways, primarily the main function is to reduce the heating circuit flow temperature as the outside temperature increases. This allows the heating to increase to its maximum set point temperature when the outside temperature reduces down to -3 C outside.

19 19 Benefits of varying flow temperature for space heating

20 20 Benefits of varying flow temperature

21 21 Standard House Application Case Study

22 22 Standard House Application Case Study Design conditions House constructed to 2000 building regulations Using the existing radiator circuit for the heating House temperature 18 o C - 21ºC. Ambient temperature 2 o C Flow temperature set point 45ºC

23 Heat load kw 23 The Reality of the Heat Pump - Case Study % hrs 452hrs 7.6% Heat load vs. Ambient 2214hrs 37% Am bient Tem perature 3326hrs 55% This leaves 2744 hours above 15 C for COPs > 4.0 for space heating, COPs > 3.0 for Hot water heating

24 24 Practical COP Space Heating Ambient Temp C Output kw COP Hrs/year Total output kwh Total input kwh -5 to to to to Totals

25 25 Practical COP Output and time weighted COP COP = = 3.32

26 26 Run Cost and CO 2 Emissions Comparison Building Area (m²) Heat Load (W/m²) Building kw Required (kw) Annual Energy Demand (kwh) Efficiency (COP) Annual CO 2 Emissions (Kg) Total Energy Cost per year ( ) HPB Gas Percentage saving 42.0% 29.5% Based on: Night Cost p/kwh Day Cost p/kwh HPB Gas m 2 house 50w/m 2 heat loss

27 27 Reduced Annual Running Costs

28 28 Reduced CO 2 Emissions

29 29 The Ecodan System

30 30 Ecodan Standalone & Packaged System The Ecodan heat pump can either be installed as a package or as a standalone system Standalone system requires the Mitsubishi Ecodan and the Mitsubishi FTC (Flow temperature controller) Packaged system uses 2 separate units: Mitsubishi Ecodan & Hi-Efficiency Hot Water Tank. The Mitsubishi unit extracts heat from the outside air and transfers it into the property in the form of hot water

31 31 1. Ecodan 2. FTC

32 32 Ecodan Heat pump Systems The Air to Water Heat Pump is a pre-assembled self contained unit mounted externally and incorporates: All refrigeration equipment assembled, tested and ready for use 2 x Pre-insulated 1 BSP water connections (flexible hoses) Boiler Buddy standard water filter system. Inline flow setter valve

33 33 Technical Introduction to New Product Range Ecodan - PUHZ W50VHA 5KW (A2 W35) heat pump boiler Power supply 16 Amp 3 core 1.5mm 2 cable Maximum running Current - 13 Amps Maximum flow rate 14.3 L/M Minimum flow rate 6.5 L/M Pipe diameter 22mm Noise level - 45dba 740mm 950mm

34 34 Technical Introduction to New Product Range Ecodan - PUHZ W85VHA 8.5KW (A2 W35) heat pump boiler Power supply 25 Amp 3 core 4mm 2 cable Maximum running Current - 23 Amps Maximum flow rate 25 L/M Minimum flow rate 10 L/M Pipe diameter 22mm 950mm Noise level - 49dba Note - This unit will supersede the PUHZ-W90VHA 950mm

35 35 Technical Introduction to New Product Range Zubadan - PUHZ HW140VHA 14KW (A2 W35) heat pump boiler Power supply 40 Amp 3 core 6mm 2 cable Maximum running Current - 35 Amps Maximum flow rate 40 L/M Minimum flow rate 20 L/M Pipe diameter *28mm 1350mm Noise level 53 dba *Increase in required pipe external diameter 1020mm

36 36 Inverter System Overview of Ecodan Key Features Inverter Driven Variable Speed Compressor No Starting Current Excellent Temperature Control Quiet Operation R410A refrigerant

37 37 Reduced Starting current Current D.O.L. Start Inverter Start Time

38 38 Improved Temperature Control On/Off Control Inverter Control Set Temperature

39 39 Refrigerants (R410A) This system contains R410A which is a blend of 2 HFCs (HydroFluoroCarbons) R32 and R125. R410A is a highly efficient refrigerant compared with it s predecessors This is a sealed system that should not leak at the end of its life the refrigerant will be recovered and destroyed

40 40 F-gas Regulations Under F-gas regulations anyone handling refrigerants should have appropriate training Not required as the Ecodan All units are hermetically sealed All contain less than 6kg of refrigerant Installer will not be considered to be handling refrigerant System repair may need a qualified refrigerant handler Analysis of system running parameters will require an understanding of the vapour compression cycle

41 41 Un-vented store expansion vessel Primary sealed system kit Inc. 3 bar relief valve Pre-charged to 1.5 bar * Supplied with package Set at 0.5 bar *Not supplied with package Sized (by the installer) on the total system volume, (allow 10 litres for the appliance pipe work)

42 42 Flow setter valve To aid in the commissioning and fault finding procedure a flow setter valve or commissioning valve is supplied with each heat pump boiler. It should be installed in the flow or return pipe-work for the heat pump boiler, an arrow indicates the direction of flow. The flow rate can be adjusted by altering the resistance screw. The valve will give an indication of the actual water flow rate which is being circulated at a given time.

43 43 Packaged System Operation

44 44 Packaged System Operation System Operation System User Controls Operational Features Ambient flow temperature adjustment

45 45 Packaged System and User Controls

46 46 Weather Compensation CHzone1 max flow temperature C and below CHzone1 min flow OWC applied C and above CHzone1 Temperature ΔT +/ - 5 C This stops the system starting and stopping

47 47 The Flow Temperature Controller Package

48 48 Flow Temperature Controller or FTC Key Features The FTC has been designed so that the Ecodan heat pump can be incorporated into a conventional heating system. All system components e.g. Time clock, thermostats, pumps can be either reused in retrofit situations or supplied & installed in a more conventional manner.

49 49 Flow Temperature Controller or FTC The FTC Package Flow Temperature Controller PAR-W21MAA (Remote Controller) TH1 (Flow Temperature Sensor)

50 50 Flow temperature Controller System Application & Operation

51 51 Standalone (FTC) System Operation System Control Chain Single System Piping and Wiring Schematics Complete System Piping and Wiring Schematics Boost Heating Switch Option PAR-W21MAA remote controller initial setting

52 52 Flow Temperature Controller or FTC The FTC is controlled and switched like a conventional gas boiler by 240V signals sent by the system components i.e. Time clock, thermostats, zone valves and pumps. A PAR-W21MAA remote controller is supplied with the FTC, this is only used to set the target flow temperatures at the commissioning stage. PAR-W21MAA Remote Controller System controls (240V) E.G Stats/Time clock (End user interface) Target flow temperature Operation mode ON/OFF FTC Ecodan HP

53 53 Flow Temperature Controller or FTC There are 2 ways of interlocking the FTC with heating systems, this is dependant on how many heating mediums are incorporated into the installation Single System Space heating only or Hot water heating only Complete System (S - Plan) Both space heating and hot water heating combined

54 Flow Temperature Controller or FTC The Single system pipe work schematic FTC TH1 sensor (supplied with FTC) must be strapped and insulated to the water FLOW pipe from the Ecodan. From our initial findings two pumps should be installed in series to achieve the required flow rates stated earlier. Ecodan HP Boiler Buddy Flow setter Pumps Internal System Either radiators/underfloor OR hot water At least 150mm pipe work between pump and setter

55 55 Flow Temperature Controller or FTC The Single system wiring schematic 2 core cable supplied with FTC PAR-W21MAA remote controller FTC Pumps Thermostat Time clock 230V 50HZ L 3 core 1.5mm Honeywell command centre (Optional) N E Ecodan HP To internal system

56 56 Flow Temperature Controller or FTC The Single system wiring termination schematic 2 = Heating TH1 1 2 Rem. Con. 1 2 TB = Hot water Heat pump S1 S2 S3 FTC Relay PCB Pumps Site TH1 Sensor PAR-W21MAA Remote controller Thermostat Time clock S1 S2 S3 Ecodan HP N L 230V / 50HZ

57 57 Flow Temperature Controller or FTC The Complete system wiring termination schematic TH1 1 2 Rem. Con. 1 2 TB Heat pump S1 S2 S3 FTC Relay PCB Site TH1 Sensor PAR-W21MAA Remote controller Honeywell command centre S1 S2 S3 Ecodan HP To system components

58 58 Flow Temperature Controller or FTC The Complete system wiring termination schematic (S-Plan) Only difference from Standard S Plan wiring 230V 50HZ L N E FTC TB145 Honeywell command centre L N HTG HW Time clock N L Room Thermostat E N Pumps L L L N Cylinder Thermostat CH ZV HW ZV L N L

59 59 Flow Temperature Controller or FTC Weather compensation & Boost switch TH1 1 2 Rem. Con. 1 2 Heating boost switch (Optional) Heat pump S1 S2 S3 FTC Relay PCB Site TH1 Sensor PAR- W21MAA Remote controller Factory fitted loop wire between terminal 1 & 3 This will provide weather compensated flow temperature or Eco Heat during heating mode

60 60 Flow Temperature Controller or FTC Weather compensation & Boost switch TH1 1 2 Rem. Con. 1 2 Heating boost switch (Optional) Heat pump S1 S2 S3 FTC Relay PCB Site TH1 Sensor PAR- W21MAA Remote controller The loop wire should be positioned between terminal 1 & 2 if a constant heating flow temperature regardless of the ambient temperature is required.

61 61 Flow Temperature Controller or FTC Weather compensation & Boost switch TH1 1 2 Rem. Con. 1 2 Heating boost switch (Option) Heat pump S1 S2 S3 FTC Relay PCB Site TH1 Sensor PAR- W21MAA Remote controller A standard 2-way switch can be installed to give the option of boosting the target flow temperature during higher ambient temperatures. *Terminal 1 must be common

62 62 Flow Temperature Controller or FTC DIP switch settings Switches on the FTC control board must be set to the following combinations, this is the factory default setting but should be checked during the commissioning stage ON OFF SW1 SW2 SW3 SW Input signal setting Liqud Set temp FTC Input signal setting Off ON

63 63 PAR-W21MAA remote controller initial setting

64 64 PAR-W21MAA remote controller initial setting When the power supply is initially switched onto the system the remote controller will flash Please wait in the left hand corner before showing the language setting screen, this is defaulted to English and just needs to be entered by pressing and holding the BACK button 2 and the button 4. for 2 seconds

65 65 PAR-W21MAA remote controller initial setting The following settings have to be programmed into the controller after the initial power up at the commissioning stage. Setting day & time Setting TH1 target flow temperatures

66 66 PAR-W21MAA remote controller initial setting Setting the day and time After initial power ON the time and day of the week need to be set To set the time use the arrows. The day of the week can be changed using the *Each press advances the day Sun Mon Fri Sat

67 67 PAR-W21MAA remote controller initial setting Setting target flow temperatures To set the target flow temperatures for all modes (HEATING/HEATING ECO/HOT WATER) the following procedure should be followed (1) Press the for 3 seconds to activate the initial setting mode.

68 68 PAR-W21MAA remote controller initial setting Setting target flow temperatures * Disregard these settings Press parameter setting to switch to the next

69 69 PAR-W21MAA remote controller initial setting Setting target flow temperatures Set the target temperature for both HEATING and HOTWATER heating with the Temp buttons

70 70 PAR-W21MAA remote controller initial setting Setting target flow temperatures 4 parameters have to be set for the target temperature in HEATING ECO or weather compensation mode (Target flow temp depends on outdoor temp). WATER TEMP HEATING ECO No.1 Display C shows target flow temp Display D shows outdoor temp WATER TEMP HEATING ECO No.2 Display C shows target flow temp Display D shows outdoor temp Press to switch between C and D - The blinking figure can be changed using Temp

71 71 PAR-W21MAA remote controller initial setting Factory settings and recommended flow temperatures (Standard application) Heating Factory setting 40 0 C Recommended setting 55 0 C Hot water heating Factory setting 50 0 C Recommended setting 58 0 C

72 72 PAR-W21MAA remote controller initial setting Factory settings and recommended flow temperatures (Standard application) Eco Heating No.1 (lower ambient temp) Factory setting C = C D = 38 0 C Recommended setting C = 2C D = 55 0 C No.2 (High ambient temp) Factory setting C = 17 0 C D = 25 0 C Recommended setting C = 17 0 C D = 30 0 C

73 73 PAR-W21MAA remote controller initial setting Setting target flow temperatures To enter the settings and enable the PCB to memorise the settings the must be pressed. The ON/OFF button 6 can then be pressed to exit the setup mode. Once this stage is reached all the ON/OFF and mode controls will be operated by the time clock/stats etc, the PAR-W21MAA will only be useful to monitor the system operation If required the remote controller can then be removed from the system and the FTC PCB will remember the settings.

74 74 PAR-W21MAA remote controller Key Features Fault code indication System operating parameters System operating parameters at the time of error

75 75 Heat Pump System Design

76 76 Heat Pump System Design Heat loss calculations Radiator / heat emitter sizing Domestic hot water storage volume Flow rates Under floor heating systems

77 77 Heat Loss Calculation Mitsubishi Electric do not carry design liability insurance General size guidance only Design responsibility of specifier to size unit correctly. Gledhill Water Storage have design service for larger projects

78 78 Heat Loss Calculation All buildings are suitable for a heat pump! Buildings should be well insulated Old buildings with solid walls have high heat losses Heat loss calculations are required for SAP on new build properties. Mitsubishi BS5449:1990 Heat Loss Calculator available for retrofit properties E-Si performs heat loss calcs for you.

79 79 Building Heat Loss Calculation Complete information in yellow shaded boxes Insert Dimensions Select figures from the Tables sheet The required boiler size is displayed

80 80 Heat Loss Calculation Available Ecodan heat pump boiler duties PUHZ-W50VHA (5KW Heating Duty) PUHZ-W85VHA (8.5KW Heating Duty) PUHZ-HW140VHA (14KW Heating Duty)

81 81 Heat Loss Calculation Please note with the W50 and W85 boilers as the ambient temperature drops the available output also drops they will still provide heat energy at C ambient. This is not applicable for the 14KW model.

82 82 Radiator Guidance Room type Complete information in yellow shaded boxes Insert Dimensions Insert Dimensions Room heat loss is displayed for radiator sizing

83 83 Radiator Guidance Heat pumps produce water at 30 C to 60 C Ideal for underfloor heating Average underfloor heating circuit 35 C Fossil fuel boilers heat water to 80 C Flow temp in rads design temp approx 70 C or more recently for condensing boilers 50C. Heat pumps can be used with radiators. Sometimes larger surface area to emit heat from lower temp water is required.

84 84 Radiator Sizing Due to lower flow temperatures provided by a heat pump boiler additional care must be taken when sizing the surface area of a radiator As the temperature difference between the primary and secondary mediums decrease, the heat exchangers surface area must increase to emit the same amount of heat energy

85 85 Radiator Sizing Tool Available from Mitsubishi Allows rad outputs at variable flow temperatures to be calculated Rule of thumb only

86 86 Radiator Sizing Comparison Large ΔT High flow temperature 0.56m² = 1.6KW Radiator Dimensions and duties

87 87 Radiator Sizing Comparison Small ΔT Low flow temperature 1.4m² = 1.6KW Radiator Dimensions and duties

88 88 Retrofit Radiators Actual surface area currently designed on appearance e.g. under a window, along length of wall Radiator under an average window = m 2 Average property likely to significantly oversized Perception is small radiator = cold room

89 89 Radiator Sizing Case Study 3 bed semi detached house built to 2006 regs Heat loss of 5.4kW (20 C/-3 C) Design flow temp of 70 C (normal boiler) Each bedrooms radiator sizes should only be approx 0.5m² at this flow temperature In reality the installed radiators were on average 1.15m² Design flow at 50 C would require radiators to be approx 1.0m²

90 90 DHW hot water usage patterns Calculations set out in the CIBSE guide should be carried out to decide the amount of DHW storage required for a building. The table below can be used as a rough guide

91 91 Domestic Hot Water Storage Cylinders and FTC DHW Cylinder Specifications Indirect type (with coil type heat exchanger) 5KW heat pump At least 2m 2 surface area coil should be used 9KW &14KW At least 3m 2 surface area coil should be used (Smaller heat exchangers can be used with Ecodan but please be aware that as the area reduces the performance and storage temperature achievable of the system is reduced) Copper construction We will have recommended specifications for stainless steel vessels after further testing High density injection or spray on foam to current building regulations Connection point for either strap-on or immersed thermostat

92 92 Domestic Hot Water Storage Cylinders and FTC Cylinder specification sheet This sheet can be completed and sent to a cylinder supplier for a quotation

93 93 Domestic Hot Water Storage Cylinders and FTC Cylinder thermostat Care should be taken when selecting a cylinder thermostat. If the stat can be set higher than the achievable storage temperature of 55 0 C then space heating will be held off due to hot water priority. It is recommended that a thermostat on which the maximum temperature can be locked is used and is of an electronic type rather than mechanical. This will prevent it asking for a temperature that cannot be achieved and preventing space heating from occurring. A Potterton PTT2 cylinder thermostat is used on our demonstration system. This also gives an indication when the set temp is achieved.

94 94 The Hot & Cold Supply Flow Rates The hot water flow rate achievable from the HP-DEM is directly related to the adequacy of the cold mains serving the property. The cold supply must be capable of providing the total simultaneous demand, this should be calculated and could be up to 60 litres/minute in some properties. The minimum flow rate recommended for an adequate mains pressure system in any property is 30 litres/minute, this should be checked before the product is applied.

95 95 Under Floor Heating Systems The BoilerMate contains a pre-fitted pump for the heating circuit (s). When using an underfloor heating system, if the manifold does NOT contain a blending valve it should be of the non-pumped type. The blending valve should be set at the design temperature of the underfloor circuit.

96 96 Summary Careful consideration must be given to appropriate application of this technology to maximise its benefits it will not suit all properties, especially many retrofits Heat emitters may need to be larger Remember lower flow temperatures maximise COP Various regulations apply to the design and installation of such systems

97 97 Application

98 98 Application Ecodan location and installation considerations Gledhill location, installation and DHW supply considerations Interconnecting pipe work and wiring

99 99 Location Considerations Weight Space requirement Anti Vibration/Noise requirements Electrical details Drainage

100 100 Space requirements Space is required around the a heat pump to allow air flow. Below is the required space for the 8.5KW heat pump, these vary for other models and can be found in the relevant installation manuals.

101 101 Space requirements Air outlet grille for each model are available to divert airflow and reduce minimum dimensions (PAC-SF08SG-E). (Figures in brackets are for 14KW model)

102 102 Space requirements As Ecodan recovers heat from the environment, the exhaust air from the fan can be uncomfortably cold, deflectors are available if the units are to be installed in a pedestrian area e.g. Patio Considerations should be made so that the area in front of the Ecodan is not going to cause to much disruption to occupants

103 103 Noise / vibration nuisance Care should be taken to prevent any vibration transfer into buildings Flexible hoses (2 x 600mm 1 bore steel braided rubber flexible hose, one for flow and one for return, supplied loose with the unit. (Supplied with package) Anti- Vibration mountings i.e Tico pad (NOT supplied with package) Noise considerations should be taken into account when locating in close proximities with other residences

104 104 General Ecodan Electrical Installation A qualified part P certified Electrician is required to install the power supply Care should be taken to ensure the power supply is weather proof Supply cable should be either armoured cable, or twin + earth protected in conduit Power should be isolated locally within 1.5 metres, minimum 3mm contact gap in isolator An RCD (residual current device) should fitted in the supply to the Ecodan this should have a tolerance of 30mA

105 105 Defrost Cycle & Drainage As the Ecodan extracts heat from the air at low temperatures the heat exchanger may accumulate a slight build up of frost/ice. The unit will detect this and automatically reverse its cycle sending hot gas (up to 60 0 C) around the coil as a defrost strategy. This usually last for less than 4 minutes.

106 106 Defrost Cycle & Drainage When the unit is providing water heating the refrigerant to air heat exchanger will cool, and therefore condense moisture from the air. This condensate will drain from the unit and provision for its disposal may be needed i.e gravel pit. Up to ~ 8L/hr

107 107 Summary and additional external considerations Clearances around unit and provision for condensate disposal Noise, visual impact on property and neighbours. e.g. avoid sitting near windows, anti vibration pads available Qualified electrician required to install power supply Planning permission Scaffolding tower and/or ladder access for installation and servicing at high level Protection from physical damage/vandalism

108 108 Electrical Considerations A qualified part P certified Electrician is required to install the power supply Power should be isolated locally within 1.5 metres 6mm core cable protected by a 32 amp MCB All other internal protection is supplied pre-wired in the package

109 109 Interconnecting pipe work and wiring Pipe work and insulation Visual Impact Essential protection requirements Wiring

110 110 Interconnecting pipe work and insulation Required pipe work diameters between outdoor and indoor. 22mm 28mm PUHZ-W50VHA PUHZ-W85VHA PUHZ-HW140VHA Note Larger diameter required for 14KW model

111 111 Interconnecting pipe work and insulation Gledhill package - interconnecting pipe run must not exceed 60 metres equivalent length (30 metres difference between units) inclusive of height difference. Standalone package flow rates for each heat pump model must be achieved by sizing the circulating pumps to suit the pipe work. Provisions should be made to fit AAV s or bleed valves at the highest point in the pipe work Pipe work MUST be insulated with Armaflex or similar insulation (thermal conductivity 0.04W/m.K). To ensure minimal thermal heat loss *(Failure to to insulate the pipe work WILL reduce the efficiency of the system dramatically) For weather protection To help prevent freezing

112 112 Air locks, evacuation and lack of flow rate Precautions should be taken to ensure the evacuation of all air from the entire primary system. To accomplish this automatic air-vents should be installed at the highest point of the primary pipe work. Failure to do so will result in the heat pump boiler displaying one of the following errors on the Ecodan PCB LED display 7 Segment LED 7 Segment LED OR U1 P6 To reset turn the power to the Ecodan OFF & ON. Continuous reset with failure to rectify the fault will result in damage to the boiler

113 113 Heating System Bypass Automatic bypass valves will be required in the heating systems if it is proposed to fit thermostatic radiator valves (TRV s) to all radiators or fit zone valves to control all the separate heating circuits. To meet the requirements of Building Regulations for a boiler interlock, it is recommended that the radiator in the area where the room thermostat is installed should be fitted with lock shield valves on both connections

114 114 The Hot & Cold Supplies If the dead leg volume of the hot water draw-off pipe work is excessive a secondary hot water circulation system could be considered. *As a rule of thumb if the hot water delivery time is greater than 60 seconds Secondary Hot Water Circulation 1. Bronze circulator 2. Expansion Vessel 3. Hot water return pipework 4. Single check valve/non return valve - should be fitted as close as possible to the Accolade 2000 appliance 2 SCV SH WHB BATH Hot flow & return pipe work must be insulated SINK WHB

115 115 Visual Impact Considerations Location of Ecodan External pipe work Minimise external pipe runs Trunking E.g inaba-denko

116 116 Interconnecting cables PUHZ-(H)W50/85/140VHA with Flow Temperature Controller A 4 core interconnecting cable is required, this is not supplied with the package Minimum conductor size 1.5mm² Must not exceed 30 Metres in length Must be one cable without any joints

117 117 Essential protection requirements Filters The heat exchanger must be protected from particulate contaminates in the water circuit. When retrofitting provision shall be taken to avoid contaminates blocking the water circuit within the Heat Pump. A Fernox boiler buddy is supplied with the package and MUST be fitted to the system between the Ecodan and Boilermate as close to the Ecodan as possible in the flow line. * It is not weather proof so should be positioned indoors

118 118 Freezing! One of the biggest risk to the system is freezing the water contained in the plate heat exchanger. Heat exchanger has 1mm capillaries Therefore vulnerable to ice damage A burst heat exchanger will cost 300 Plus a days labour from a fridge engineer Possible compressor damage Potential bill of 900+

119 119 Essential protection requirements Provision shall be taken to avoid this pipe work freezing during winter months i.e. antifreeze/inhibitor, such as: Fernox PROTECTOR ALPHI-11 Protects against corrosion and limescale commonly used in heating systems Non-toxic, environmentally friendly Combined antifreeze and inhibitor Should make up 25% of the total volume.

120 120 Commissioning

121 121 Commissioning Checklist Add Fernox Alphi 11 (anti freeze) Check air charge is in expansion vessels Pressurise primary circuit to approximately 1.50 Bar Open all isolating valves Release ALL air from the system using automatic air vents at the highest points of the system

122 122 Commissioning Before bleeding the air from the system the zone valves should be manually opened to prevent air lock and possible damage of the circulating pumps.

123 123 FTC System Commissioning Operate the system by selecting constant run for BOTH channels on the installed two channel time clock DHW heating will then take priority and raise the hot water store until the cylinder thermostat is opened. Once this temperature is achieved check that the DHW zone valve closes and CH valve opens. With the boost switch link between terminals 1 and 2 the system should then target the preset temperature selected in heating mode during the Initial Setting mode.

124 124 Commissioning Indications should be placed on the system and in the house instructions to ensure that if for any reason the heating system is emptied the anti-freeze in the pipe-work is replaced.

125 125 Service and Maintenance

126 126 Annual Servicing (Boilermate) Service/maintenance recommendations relating to the Un-vented store. Check that the correct rating and type of fuse is fitted to the electrical supply. Check for the presence of supplementary earth bonding. Clean out the strainer in the combination valve. Check the expansion charge pressure and top up if necessary (1.5 bar). Clean flow regulators (restrictors/aerators) as applicable and check for correct flow rate.

127 127 Annual Servicing (Ecodan) Low maintenance sealed system Like a fridge! Refrigeration engineer not required Essentially a visual inspection Unit needs to be kept clear of debris Check for signs of damage to unit Heat exchanger to be kept clean - Calclean environmentally friendly coil cleaner - Brush to remove debris e.g. leaves

128 128 System Monitoring & Diagnosis LED Display inside Ecodan Unit 7 Segment LED ON Display Comp 4-way valve Solenoid valve Warm up ON 2 - ON Display O C H d Mode Off Cool Heat Defrost 3 - ON ON 4 ON - 5 ON - ON 6 ON ON 7 ON ON ON 8 ON

129 129 System Monitoring Set dip switches to monitor system parameters either current or pre fault condition Please Refer to the Technical Manual for Settings Note settings are not the same as other Mr. Slim ON Segment LED

130 130 System monitoring examples Water inlet temperature (TH32) Ambient temperature (TH7) LEV-A & B opening pulses Discharge temperature (TH4) Discharge superheat Compressor running current Note All of the above examples can be checked for current or pre fault code values

131 131 Air to Water Ecodan Refrigerant Circuit P-sensor TH7 8 TH3 Water out 9 2 Plate H/ex. TH TH4 HP switch Water in TH6 11 7

132 132 Ecodan Monitoring Parameters P-sensor TH7 Water out TH3 Plate H/ex. HP switch TH4 TH32 Water in TH6

133 133 Warm up mode on 4 hours 30 min off 30 min At power on, warm up mode operates 4 hours & stops 30mins Outdoor temp 21 c or less warm up mode operates 30mins & stops 30mins Compressor buzzes Unit Applies Low frequency, Low current power to the compressor

134 134 Regulations and Legislation

135 135 Regulations Working at Heights Approved Document P: Electrical Safety Approved Document E: Resistance to the Passage of Sound Approved Document B: Fire Safety Approved Document L1A: Conservation of Fuel and Power (New Dwellings)

136 136 Electrical Regulations Approved Document P: to cover power supply to Gledhill Unit Approved Document P: to cover power supply to Mitsubishi Unit Wiring Regulations: 17th Edition apply in both cases

137 137 Approved Document P: Electrical Safety Third party certification is not permitted The installation and commissioning of external mains voltage equipment is a controlled service The interconnecting wiring is not subject to approved document P, as it only carries 12v and is classed as extra low voltage

138 138 Additional Qualifications Installers must have attained a City & Guilds Certificate (6084) in Energy Efficiency to commission the unit What the C&G 6084 course covers: Why energy consumption affects the environment How energy efficiency affects the heating installer Legislation that forces change The requirements of Approved Doc. L and supporting documents such as CHeSS

139 139 Approved Document L1A: Conservation of Fuel and Power (New Dwellings) Installations must conform with this document The Domestic Heating Compliance Guide gives further guidance The installation of heat producing equipment is a controlled service Standard Assessment Procedure (SAP)

140 140 Microgeneration Requirements The government has produced a Microgeneration Installation Standard This outlines best practice for heat pump installations Any Grants and/or tax concessions will be dependant upon adhering to this standard Installations need to meet the requirements of the HVCA Guide to Good Practice Heat Pumps (TR/30)

141 141 Microgeneration Requirements Installers must have current accreditation such as:- Appropriate NVQ level 3 Other relevant training e.g. Manufacturer s product training Membership of a competent person scheme Possession of a relevant Skillcard Experience gained through a mentoring process Demonstrable track record of successful installation The relevance of the above will require independent verification

142 142 Microgeneration Requirements The contractor must understand the design and its application and explain this to the customer This explanation must include the proportion of design heat loss and design hot water load to be supplied by the heat pump and an estimate of the annual energy performance The following disclaimer must be included:

143 143 Microgeneration Requirements - Disclaimer The performance of Microgeneration heat pump systems is impossible to predict with certainty due to the variability of the climate and its subsequent effect on both heat supply and demand. This estimate is based upon the best available information but is given as guidance only and should not be considered as a guarantee.

144 144 The Future of the Heat Pump Cleaner electricity generation Lower CO2 emissions Heat pump advantage grows Carbon free generation = carbon free heating Low carbon electricity generation is enhanced by a factor equal to the COP of the heat pump Carbon savings from installed heat pumps will improve as each year passes

145 145 The Future of the Heat Pump If CO2 emission reduction is important, the heat pump has a big future The air heating products have been available for some time The water heating products have now arrived Advances in technology have now made water heating a more than viable option

146 146 Thank you Discussion

Ecodan Air Source Heat Pump and Flow Temperature Controller 2

Ecodan Air Source Heat Pump and Flow Temperature Controller 2 FTC STANDALONE Design, Installation & Servicing Instructions September 2011 Ecodan Air Source Heat Pump and Flow Temperature Controller 2 Flow temperature Controller 2 model Number PAC-IF03IB-E (FTC2)

More information

Design, Installation & Servicing Instructions

Design, Installation & Servicing Instructions Ecodan Air Source Heat Pump A complete package to provide hot water and heating in domestic housing from an air source heat pump Design, Installation & Servicing Instructions BoilerMate Model Numbers BMA

More information

Commissioning Pack. Heating and Hot Water Heat Pumps. IMPORTANT DOCUMENTS To Be Kept At All Times. With Equipment. Accredited Ecodan Installer:

Commissioning Pack. Heating and Hot Water Heat Pumps. IMPORTANT DOCUMENTS To Be Kept At All Times. With Equipment. Accredited Ecodan Installer: Accredited Ecodan Installer: Telephone: Email: Address: Commissioning Pack Heating and Hot Water Heat Pumps IMPORTANT DOCUMENTS To Be Kept At All Times With Equipment IMPORTANT This Sheet Must Be Kept

More information

Saving energy comes naturally to us.

Saving energy comes naturally to us. Domestic Heat Pumps Saving energy comes naturally to us. Low carbon solutions for heating and hot water The sustainable heating solution for today and tomorrow Home heating with lashings of hot water Whether

More information

heat interface units A BOILER WITHOUT A FLAME

heat interface units A BOILER WITHOUT A FLAME A BOILER WITHOUT A FLAME heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment in the building.

More information

TOSHIBA AIR CONDITIONING

TOSHIBA AIR CONDITIONING Introduction The following specification describes the Toshiba Estia Air to Water Heat Pump system(s) to be installed at the site below: (ADD SITE NAME) The system(s) shall consist of the following components.

More information

Central Home Heating and Hot Water Supply

Central Home Heating and Hot Water Supply Central Home Heating and Hot Water Supply Next Generation Central Home Heating and Hot Water Combined. Ecodan Next Generation Central Heating and Hot Water Heating Combined Increasing energy bills, coupled

More information

Ecodan Aerocyl Plus-me: Air Source Heat Pump and Stainless Steel Cylinder

Ecodan Aerocyl Plus-me: Air Source Heat Pump and Stainless Steel Cylinder HOMEOWNER KINGSPAN Homeowner s User Instructions MARCH 2012 Ecodan Aerocyl Plus-me: Air Source Heat Pump and Stainless Steel Cylinder Ecodan Air Source Heat Pump Model Number PUHZ-W50VHA(2)-BS PUHZ-W85VHA(2)-BS

More information

Inverter Hot Water Heat Pumps

Inverter Hot Water Heat Pumps Inverter Hot Water Heat Pumps Inverter Hot Water Heat Pumps Hot Water Heat Pump Systems Underfloor Heating Swimming Pools Spa Pools Sanitary Water Pre-heating Hydroponics Aquaculture Water Chilling Hot

More information

Kills bills. How Vaillant technologies reduce home heating bills

Kills bills. How Vaillant technologies reduce home heating bills Kills bills How Vaillant technologies reduce home heating bills Energy efficiency is a choice For most people, home heating and hot water systems have always been out of sight and out of mind. But now,

More information

Samsung Eco Heating System

Samsung Eco Heating System Samsung Eco Heating System Pre Sales Technical Information Powerful and eco-friendly air to water solutions for heating 2 Welcome This pre-sales manual has been developed for both the installer and end

More information

UK arotherm Schematics and installation guide

UK arotherm Schematics and installation guide UK arotherm Schematics and installation guide Air to Water Heat Pumps (AWHP) Controls: VRC 700, VR 70, VR 91 The Vaillant heat pump booklet contains documentation to assist in the design, installation

More information

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500 Unvented Calorifier Range. Operating and Maintenance Manual. For Models 125 300 & 500 Telephone 08456 448802 Fax 08456 448803 Emial info@mhgheating.co.uk Web www.mhgheating.co.uk TABLE OF CONTENTS. Section

More information

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. Installation and Servicing Instructions

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. Installation and Servicing Instructions Grant Aerona³ Air to Water High Efficiency Heat Pump Range Installation and Servicing Instructions UK DOC 0109 Rev 2.2 October 2018 Important Note for Installers These instructions are intended to guide

More information

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment Outdoor One or more indoor or outdoor units Indoor 1 Domestic hot water 2 Heating 3 Cooling Daikin Altherma

More information

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. Installation and Servicing Instructions

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. Installation and Servicing Instructions Grant Aerona³ Air to Water High Efficiency Heat Pump Range Installation and Servicing Instructions UK DOC 0109 Rev 2.0 June 2017 important note for installers This manual is intended to guide Installers

More information

AEC Air Source Heat Pump Installation Manual

AEC Air Source Heat Pump Installation Manual AEC Air Source Heat Pump Installation Manual Legislation The installation of these models must comply with the standards listed below: Building Regulations I.E.E. Requirements for Electrical Installations

More information

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. Installation and Servicing Instructions

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. Installation and Servicing Instructions Grant Aerona³ Air to Water High Efficiency Heat Pump Range Installation and Servicing Instructions UK DOC 0109 Rev 2.1 March 2018 Important Note for Installers This manual is intended to guide Installers

More information

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2 UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2 Version: 2018_07_19_v2.2 Abstract This is a quick reference guide for selecting the UniQ range of heat batteries for the required application. For designing a

More information

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions Grant Aerona³ Air to Water High Efficiency Heat Pump Range User Instructions UK DOC 0112 Rev 1.0 April 2017 Special Tex t Formats The following special text formats are used in this manual for the purposes

More information

Frequently Asked Questions

Frequently Asked Questions Air Source Heat Pumps Frequently Asked Questions Heating that doesn t cost the earth What are the benefits of Air Source Heat Pumps over Ground Source Heat Pumps? There are a number of benefits when using

More information

Quick Reference. Air to Water Heat Pump Series 4 Lot 1 Standard & Powerful Types

Quick Reference. Air to Water Heat Pump Series 4 Lot 1 Standard & Powerful Types Quick Reference Air to Water Heat Pump Series 4 Lot Standard & Powerful Types Estia Series 4 Standard Type Models: Hydro unit HWS-804XWHM3-E HWS-804XWHT6-E HWS-804XWHT9-E HWS-404XWHM3-E HWS-404XWHT6-E

More information

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex. A-Class A-Rated Homes with Dimplex heat pumps Building Regulations and Part L Compliance made easy with Dimplex. The name you can trust. dimplex.ie AClass A4 Page Brochure-August 2016.indd 1 A-Class Heat

More information

TERMO ELECTRIC BOILERS MANUAL OSO TERMO RS -E OSO TERMO PLUS - E OSO TERMO PTV E

TERMO ELECTRIC BOILERS MANUAL OSO TERMO RS -E OSO TERMO PLUS - E OSO TERMO PTV E TERMO ELECTRIC BOILERS MANUAL OSO TERMO RS -E OSO TERMO PLUS - E OSO TERMO PTV E B C Contents 1. Introduction... 1 1.1. Applicable documents... 1 1.2. Retention of documents... 1 1.3. Features and benefits...

More information

Air Source Heat Pump Installation and Maintenance Manual

Air Source Heat Pump Installation and Maintenance Manual Air Source Heat Pump Installation and Maintenance Manual Model Numbers: AroTHERM VWZAI wiring centre VRC700 remote controller Scan this code to go directly to our YouTube channel 2016 b 1 The Outdoor Unit

More information

Installation and Servicing Instructions. Alpha FlowSmart

Installation and Servicing Instructions. Alpha FlowSmart Installation and Servicing Instructions Alpha FlowSmart Hot Water System incorporating an Alpha InTec 30/40GS Condensing Combination Boiler with Integrated Flue Gas Heat Recovery Device and wall mounted

More information

Air to water Heat Pump System

Air to water Heat Pump System Air to water Heat Pump System 2 The heating and cooling systems of the future! A step in the right direction of reducing pollution and CO₂ emissions The increase of CO₂ and other green house gases is a

More information

Samsung EHS Heat Pump Test

Samsung EHS Heat Pump Test Samsung EHS Heat Pump Test The following questionnaire is designed for installers who have experience with heat pumps, are currently MCS accredited, and who want to fast track their Samsung accreditation

More information

Hot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY

Hot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY Hot Water Energy Storage HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY THE HOT WATER PEOPLE Hot Water Energy Storage THE HOT WATER PEOPLE Providing premium hot

More information

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS Today s inescapable need to improve energy efficiency in UK homes has brought installers many opportunities to make extra earnings through the upgrading

More information

Tel: Heronhill - For all your Toshiba heating and cooling requirements Air to water Heat Pump System

Tel: Heronhill - For all your Toshiba heating and cooling requirements   Air to water Heat Pump System Air to water Heat Pump System 2 The heating and cooling systems of the future! A step in the right direction of reducing pollution and CO₂ emissions The increase of CO₂ and other green house gases is a

More information

ADVANCE ELECTRIC THERMAL STORE

ADVANCE ELECTRIC THERMAL STORE ISSUE 13 1118 INSTALLATION AND USER GUIDE ADVANCE ELECTRIC THERMAL STORE ADVANCE APPLIANCES LTD HOUSEHOLDER PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE. 2 INTRODUCTION Advance thermal

More information

Grant UK Aerona³. Air to Water High Efficiency Heat Pump Range. Installation and Servicing Instructions

Grant UK Aerona³. Air to Water High Efficiency Heat Pump Range. Installation and Servicing Instructions Grant UK Aerona³ Air to Water High Efficiency Heat Pump Range Installation and Servicing Instructions UK DOC 0109 Rev 1.1 May 2016 Special Tex t Formats The following special text formats are used in this

More information

Installer Please Read Instructions Inside

Installer Please Read Instructions Inside Installer Please Read Instructions Inside www.samsungehs.co.uk G Hendra November 2014 1 Air Source Heat Pump Installation and Maintenance Manual Non TDM Split Systems Model Numbers: AEN08 and 160/YDEHA/EU

More information

Energy Efficiency in New Housing

Energy Efficiency in New Housing Energy Efficiency Best Practice in Housing Energy Efficiency in New Housing Summary of Specifications for England, Wales and Scotland how to achieve the best in energy efficiency in new housing measures

More information

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water New Zip AquaFlo Stainless steel cylinders for mains pressure hot water 2 AquaFlo II Zip AquaFlo II is a range of direct and indirect stainless steel cylinders designed to provide mains pressure hot water

More information

Contents. Specifications. Description SV HP 55 SV HP 90. Specifications Warnings Introduction Overview... 4

Contents. Specifications. Description SV HP 55 SV HP 90. Specifications Warnings Introduction Overview... 4 Contents Specifications Specifications... 1 Warnings... 2 Introduction... 3 Overview... 4 Installation Instructions... 5 Cable Connections... 6 Plumbing Diagram... 7 Electrical Wiring Diagram... 8 SV System

More information

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS 3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: 32305600 OPERATION & MAINTENANCE INSTRUCTIONS 0304 Parts List Item Part No Description Qty 1 FT900001 Top Cover 1 2 FT900002 Filter

More information

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION SOLARCYL IM/SC INSTALLATION MANUAL This manual gives detailed advice for installation and should be read carefully prior to fitting any unvented

More information

HT V2 HT Split

HT V2 HT Split Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single

More information

Installation & User Instructions

Installation & User Instructions Grant Aerona Air Source Heat Pump Air to Water Heat Pump Range Installation & User Instructions Tested to BS EN 14511 Part No. DOC.87 Rev.05 January 2011 i STOP STOP! Before continuing with the installation

More information

S Y D. HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance

S Y D. HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner Installation & Maintenance Fig. 1 Nomenclature Nomenclature e.g. H W P 3 5 C K Series Size Type S Y D GENERAL

More information

GB24 & GB30. User Manual

GB24 & GB30. User Manual GB24 & GB30 User Manual BOILER OUTPUT To Domestic Hot Water:To Central Heating: GB24/30 Minimum 8.0 kw (27,296 Btu/h) GB24 Maximum 24.2 kw (82,570 Btu/h) GB30 Maximum 30.3 kw (103,384 Btu/h) GB24/30 Minimum

More information

Energy Efficiency Standards

Energy Efficiency Standards GENERAL INFORMATION LEAFLET 72 Energy Efficiency Standards For new and existing dwellings GENERAL INFORMATION LEAFLET 72 BEST PRACTICE PROGRAMME INTRODUCTION The Housing Energy Efficiency Best Practice

More information

Sweden s leading air source heat pump

Sweden s leading air source heat pump - Since 1939 ExoAir / ExoAir Polaris GreenEnergy Sweden s leading air source heat pump BEST IN TEST The Swedish Energy Council recently scored the Euronom air source heat pump as the leading product of

More information

Moor Heating Air Source Heat Pump Case Study

Moor Heating Air Source Heat Pump Case Study Moor Heating Air Source Heat Pump Case Study This case study is based on an air source heat pump installed by Solarwall for Annette Hudpseth and Neil Bye. They live in a four bedroom maisonette above a

More information

Assessment Schedule - TS.6

Assessment Schedule - TS.6 The Assessor shall determine the business s commitment and support to good and safe working practices; also that it has a positive culture in all aspects of its work. In particular, the assessor shall

More information

Stored Water District Heating Interface Units. Heat Interface Units

Stored Water District Heating Interface Units. Heat Interface Units Stored Water District Heating Interface Units Heat Interface Units Why choose Elson Elson are a Heatrae Sadia company, the UK s leading manufacturer of hot water solutions utilising thermal store technology

More information

Hot Water Heat Pump Catalogue

Hot Water Heat Pump Catalogue Hot Water Heat Pump Catalogue 1 Contents Why Choose a Hot Water Heat Pump? p.4 There s a lot to consider when choosing heating for your home and many factors that may help you decide. Hot water heat pumps

More information

ADVANCE ECB ELECTRIC COMBINATION BOILER

ADVANCE ECB ELECTRIC COMBINATION BOILER ISSUE ISSUE 45 0115 0317 INSTALLATION AND USER GUIDE ADVANCE ECB ELECTRIC COMBINATION BOILER ADVANCE APPLIANCES LTD HOUSEHOLDER - PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE 1 SCHEMATIC

More information

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet: PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL Operation and Maintenance THERMAL INTEGRATION LTD. Tel: 0845 2411441 Internet: www.heatweb.com Introduction The District Pandora Heat Bank provides hot

More information

Alpha FlowSmart 25 and 50

Alpha FlowSmart 25 and 50 Installation and Servicing Instructions Alpha FlowSmart 25 and 50 Hot Water System incorporating a Flue Gas Heat Recovery Device, Primary Store and an Alpha CD Condensing Combination Boiler For Technical

More information

Installation and Commissioning Manual

Installation and Commissioning Manual Manual Advance Buffer Vessels for Ground Source Heat Pump Systems Installation and Commissioning Manual Copyright 2015 Kensa Heat Pumps Ltd Page 1 of 12 Contents Page Section Description Page 1... Safety

More information

Daikin Altherma Hybrid User Guide

Daikin Altherma Hybrid User Guide Daikin Altherma Hybrid User Guide Your new Daikin Altherma hybrid heat pump In this guide you will find information and guidelines that will allow you to run your Daikin Altherma hybrid heat pump system

More information

SmartRad Planning Manual

SmartRad Planning Manual SmartRad Planning Manual Issue 1 15 April 2010 Dimplex SmartRad Fan Convector Models SRX80, SRX120, SRX140 & SRX180 Applies to models with White Glass, Black Glass and Metal facias Contents 1 Introduction

More information

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of

More information

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for unvented systems.

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for unvented systems. ECONOPLATE H1-heat only HEAT INTERFACE UNIT Installation, Commissioning and Servicing Instructions for unvented systems. Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING,

More information

TERMO ELECTRIC BOILER INSTALLATION MANUAL OSO TERMO RS -M

TERMO ELECTRIC BOILER INSTALLATION MANUAL OSO TERMO RS -M TERMO ELECTRIC BOILER INSTALLATION MANUAL OSO TERMO RS -M Contents 1. Introduction... 1 1.1. Applicable documents... 1 1.2. Retention of documents... 1 1.3. Features & benefits... 1 1.4. Operation of domestic

More information

2012 Heating Price List. Price List Heating 1st November Mitsubishi Electric is a market leader in renewable solutions.

2012 Heating Price List. Price List Heating 1st November Mitsubishi Electric is a market leader in renewable solutions. 2012 Heating Price List Mitsubishi Electric is a market leader in renewable solutions. In recent years we ve developed our range of low carbon heating to address the increasing need to improve efficiency

More information

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser Vitocal 300-A, type AWC-I and AW-O.1 Product description A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser & High operational reliability,

More information

SEALED THERMAL STORE

SEALED THERMAL STORE ISSUE 3 0717 INSTALLATION AND USER GUIDE ENERGYMANAGER SEALED THERMAL STORE ADVANCE APPLIANCES LTD PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE. SCHEMATIC DIAGRAM OF ENERYMANAGER THERMAL

More information

CHOOSING A COOLING SYSTEM

CHOOSING A COOLING SYSTEM CHOOSING A COOLING SYSTEM Do you dread the thought of enduring another sweltering summer of sleepless nights? Can you no longer bear living in a hot box and want to install a cooling system but don t know

More information

Installation instructions. RECOUP Retrofit+ Shower Waste Water Heat Recover unit

Installation instructions. RECOUP Retrofit+ Shower Waste Water Heat Recover unit Installation instructions RECOUP Retrofit+ Shower Waste Water Heat Recover unit These instructions are to be left with the user for the homes user pack Contents SECTION PAGE. Introduction 3. 2. Product

More information

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint Home Heating Guide Why Vaillant? Because they can reduce our heating bills and our carbon footprint Because we re here to help If you have any questions, please call 01634 292300. We can also give you

More information

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

WHHR125DC Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use "WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor Installation, Operating and Maintenance Instructions domestic and commercial use Page 2 Contents Section Page Number Introduction 3 How

More information

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15 CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15 COMPACT PLUS 10 and 15 Litre Unvented Under and Over Sink Water Heater INSTALLATION AND USER GUIDE 1 DIMENSIONS 10L - 250mm 15L - 310mm 100mm 80mm 410mm

More information

Home owner user pack for the Nibe 200P

Home owner user pack for the Nibe 200P Home owner user pack for the Nibe 200P How to use this pack: Section 1 Please print these pages and laminate back to back to create a single document. This laminated document should be left with the Unit

More information

Installation & Technical Guide. Domestic & Commercial.

Installation & Technical Guide. Domestic & Commercial. Installation & Technical Guide Domestic & Commercial www.challisbooster.com www.challisboosterplus.com Installation and Technical Guide Domestic and Commercial Challis Water Controls Europower House, Lower

More information

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space. DPS Hi-Flow Mains Pressure Hot Water from an existing vented copper cylinder... Converts an existing hot water cylinder to provide potable mains pressure hot water at high flow rates to all existing outlets.

More information

SOLAR HEATING SYSTEMS

SOLAR HEATING SYSTEMS introducing SOLAR HEATING SYSTEMS TM the low carbon water heating system June 2008 Irl 1 In this environmentally challenging world, it s time to rethink our heating.....while we still have time. There

More information

OPTIONAL SPRING MTG HANGING CENTRES WATER CONN'S: TWO BSP MALE. 19 mm (3/4") ELECTRICAL CONDUIT HOLES ACCESS PANEL OUT (WATER) IN 485 MOUNTING

OPTIONAL SPRING MTG HANGING CENTRES WATER CONN'S: TWO BSP MALE. 19 mm (3/4) ELECTRICAL CONDUIT HOLES ACCESS PANEL OUT (WATER) IN 485 MOUNTING HWP 117 225 Ducted Water Cooled R410A Packaged Air Conditioner Dimensions (mm) Fig. 1 HWP 117 60 1210 SPRING MOUNTING CENTRES 690 (HEIGHT = 370) FILTER BOX PROJECTION Net Weight 105 kg Installation & Maintenance

More information

Advance Split

Advance Split Engineering Data Manual Aqu@Scop Advance Split Air-to-Water DC Inverter Split Heat Pumps Models 005, 008, 012 & 014 2 to 16 kw Strength Points Most efficient heating technology with variable speed compressor.

More information

S D HWP 77, 96. Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance. Fig. 1 Nomenclature. Fig.

S D HWP 77, 96. Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance. Fig. 1 Nomenclature. Fig. HWP 77, 96 Ducted Water Cooled R410A Packaged Air Conditioner Installation & Maintenance Fig. 1 Nomenclature Nomenclature e.g. H W P 7 7 C K Series Size Type S D GENERAL HWP - A general designation which

More information

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website 17/04/2012 CI/SFB [56] www.dimplex.co.uk ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website The information is correct at time of downloading,

More information

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses INSPIRED H I G H H O T EF F ICIENCY E F F I C I E N C Y W A T E R S Y S T E M S E XT REME HIGH EFFICIENCY HO T W AT ER SY ST EMS w i th I N JECT I O N DYN A M I C S T ECHN I CAL DO CUME N TA T I O N I

More information

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION 0 RD 0 RI 0000-06 IM/ IM/a INSTALLATION MANUAL This manual gives detailed advice for installation and should be read carefully prior to fitting

More information

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table) 1 2 Warning: - Do not place your hand or any other objects into the air outlet and fan. It could damage the heat pump and cause injuries; - In case of any abnormality with the heat pump, cut off the power

More information

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE ISSUE 6 1016 INSTALLATION AND USER GUIDE ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE ADVANCE APPLIANCES LTD PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE. IMPORTANT: Gravity circultation

More information

Heat emitters for Heat Pump systems. Bill Bucknell

Heat emitters for Heat Pump systems. Bill Bucknell Heat emitters for Heat Pump systems Bill Bucknell The Institute Founded in 1964 Systems incorporating circulating pumps needed for small-bore pipework Need careful design Entry into membership via one-year

More information

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS G R A N T C Y L I N D E R & S T O R E R A N G E High Efficiency Direct and Indirect Hot Water Storage Solutions FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS GRANT DUOWAVE

More information

FREQUENTLY ASKED QUESTIONS

FREQUENTLY ASKED QUESTIONS HEAT PUMP INVERTER R-410A All-in-one, all year round heating, cooling and domestic hot water supply solution FREQUENTLY ASKED QUESTIONS WANT TO KNOW MORE? AVERAGE ANNUAL CO 2 EMISSIONS Daikin Altherma

More information

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE

More information

Technical description. Atec.

Technical description. Atec. www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.

More information

Heat pumps in the UK. a monitoring report GENERAL INFORMATION REPORT 72 BEST PRACTICE PROGRAMME

Heat pumps in the UK. a monitoring report GENERAL INFORMATION REPORT 72 BEST PRACTICE PROGRAMME GENERAL INFORMATION REPORT 72 Heat pumps in the UK a monitoring report GENERAL INFORMATION REPORT 72 BEST PRACTICE PROGRAMME 1 INTRODUCTION PROJECT SUMMARY This Report summarises the performance monitoring

More information

HP RECESSED HEAT PUMP RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. For use with Mr Slim Outdoor Units

HP RECESSED HEAT PUMP RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. For use with Mr Slim Outdoor Units ErP compliant HP RECESSED HEAT PUMP RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS For use with Mr Slim Outdoor Units PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION

More information

Air to water Heat Pump System

Air to water Heat Pump System Air to water Heat Pump System 2 The heating and cooling systems of the future! A step in the right direction of reducing pollution and CO₂ emissions The increase of CO₂ and other green house gases is a

More information

ELECTRIC COMBINATION BOILER. (European Patent No: Design Right Protected.) TH12-450U MRK 2

ELECTRIC COMBINATION BOILER. (European Patent No: Design Right Protected.) TH12-450U MRK 2 ELECTRIC COMBINATION BOILER (European Patent : 1757678. Design Right Protected.) TH12-450U MRK 2 INCLUDES THERMAL SOLAR & WOOD BURNING STOVE WITH WATER JACKET APPENDIX This product is suitable for connection

More information

INSTALLATION & TECHNICAL MANUAL

INSTALLATION & TECHNICAL MANUAL The COMET Range of Boilers the ultimate solution for central heating INSTALLATION & TECHNICAL MANUAL If you require any further assistance: Telephone: 01698 820533 Fax: 01698 825697 E-mail: info@electric-heatingcompany.co.uk

More information

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler H o t Wa te r Syste m s Senator Electric Flow Boilers Making Life Simpler Electric Wet Central Heating The Range Senator electric flow boiler is designed to heat re-circulated water used in wet central

More information

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Technical Development Program COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Introduction System

More information

HOT WATER SYSTEMS.

HOT WATER SYSTEMS. HOT WATER SYSTEMS www.thermann.com.au GAS STORAGE HOT WATER SYSTEM The Thermann 4* Gas hot water heater can suit any family type. With an adjustable thermostat for safety and efficiency it allows you to

More information

Electric Flow Boiler

Electric Flow Boiler Electric Flow Boiler InstallatIon & technical Manual If you require any further assistance: telephone: 01698 820533 Fax: 01698 825697 E-mail: info@electric-heatingcompany.co.uk or visit our website www.electric-heatingcompany.co.uk

More information

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy A total hot water and heating thermal store that can also make the most of renewable energy Design, Installation & Servicing Instructions All models comply with the Hot Water Association specification

More information

CoziStat. 1. Introduction and Brief Description COZISTAT INSTALLATION I NSTRUCTIONS &OPERATING MANUAL

CoziStat. 1. Introduction and Brief Description COZISTAT INSTALLATION I NSTRUCTIONS &OPERATING MANUAL COZISTAT INSTALLATION I NSTRUCTIONS &OPERATING MANUAL CoziStat 1. Introduction and Brief Description The CoziStat is an easy-to-use, programmable thermostat with digital display. CoziStat can be used with

More information

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system Viewpoint August 2012 Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system Dr Sarah Price and Helen Brown Summary Mechanical Ventilation and Heat

More information

Service Step by Step Trouble-Shooting Check-List

Service Step by Step Trouble-Shooting Check-List WARNING: Only Data Aire trained technician or experience technicians should be working on Data Aire Equipment. Protect yourself at all times and work safe. Date: Dates at the job site: From: to Job#: Serial#:

More information

PACKAGED TYPE. Water heat exchanger is built in the outdoor units. OPTIONAL PARTS LIST. Step Interface 3) Flow Temperature Controller 3)

PACKAGED TYPE. Water heat exchanger is built in the outdoor units. OPTIONAL PARTS LIST. Step Interface 3) Flow Temperature Controller 3) 27 - - SERIES LINE-UP Mitsubishi Electric have a good variety of units depending on conditions for installation sites. PCKGED TYPE Water heat exchanger is built in the outdoor units. 2HP 3HP 4HP 5HP Power

More information

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd Abstract This paper presents the design approach adopted for the expansion of a large existing

More information

Twin Compressor Compact Heat Pump. Installation and Commissioning Manual

Twin Compressor Compact Heat Pump. Installation and Commissioning Manual Heat Pump Warranty Fault Finding Commissioning General product Introduction Manual Twin Compressor Compact Heat Pump and Commissioning Manual Copyright 2016 Kensa Heat Pumps Ltd Page 1 of 42 Introduction

More information

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24 Refrigeration / Air Conditioning Systems Circuit Drawings Nominal Student Hours: Student Resource Package No: NR 24 24 Hours. Delivery: Recognition of Prior Learning: Package Purpose: Suggested Resources:

More information