Open Vented Condensing Boilers

Size: px
Start display at page:

Download "Open Vented Condensing Boilers"

Transcription

1 Dimplex 18 OV Dimplex 32 OV Open Vented Condensing Boilers User s Operating Instructions These instructions should be left with the user Dimplex Boilers 2008

2 CONTENTS SECTION DESCRIPTION PAGE 1.0 Using the Boiler Problem Solving Safety Error Codes Additional Information 7 Read these instructions carefully before trying to operate the appliance. GAS COUNCIL NUMBERS Natural Gas Dimplex 18 OV - Gas Council Appliance : Dimplex 32 OV - Gas Council Appliance : Control Panel Fig. 1 2 Dimplex Boilers 2008

3 1.0 USING THE BOILER 1.1 CONTROL PANEL Fig. 2 7 segments LED display Central Heating Temperature Control 1.2 CH - CENTRAL HEATING TEMPERATURE CONTROL Control knob shown in the OFF position. Turn the knob clockwise to increase the temperature of the central heating. Min Max 1.3 TO LIGHT THE BOILER 1. Switch on the electrical supply. Fig Turn the CH temperature Control knob to the midpoint between the minimum and maximum setting. The display changes from O to h. 3. Ensure Programmer and room thermostat (if fitted) are calling for heat. Digital Display 4. The display changes to H. When the boiler has lit a small dot will also appear in the bottom right corner of the display. 5. If the burner fails to light the fan will stop. Initially this may be due to air in the gas supply. The boiler will automatically have five attempts at ignition. Fig. 4 Burner On Light 6. After the five attempts it may be necessary to RESET the boiler by turning the control knob to the RESET/STANDBY position and back to ON within TWO seconds (then repeat step 2). 1.4 CH - CENTRAL HEATING TEMPERATURE CONTROL Adjustable via the CH temperature control knob to give radiator temperatures of between 30 C and 80 C. Min Max During periods of no central heating requirement, the control should be set to the STANDBY position but the permanent live to the boiler should be left on. Fig. 5 Dimplex Boilers

4 2.0 PROBLEM SOLVING 2.1 STEP BY STEP GUIDE Boiler t Working Check that the gas supply is turned on. Are other gas appliances working? Consult gas supplier Is the central heating indicator light on? Is the CH temperature control knob ON? Turn the knob clockwise Is the timer on and calling for heat? Ensure the timer is set for central heating on (see your timerinstructions) Is the room thermostat set high enough? Turn the room thermostat to maximum Reset the boiler - see Section 5.7. If the boiler does not reset, contact your installer or service engineer 4 Dimplex Boilers 2008

5 3.0 SAFETY 3.1 GENERAL SAFETY DO NOT interfere with any sealed components and use the appliance only in accordance with these instructions. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack experience and knowledge, unless they have been given supervision or instructions concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. 5mm Min 5mm Min 200mm 3.2 CURRENT GAS SAFETY (INSTALLATION & USE) REGULATIONS It is the law that all gas appliances are installed by a competant person in accordance with the above regulations. Failure to install appliances correctly could lead to prosecution. It is in your own interest, and that of safety, to ensure that the law is complied with. If the appliance is damaged, turn off the appliance and consult a CORGI registered installer. If it is known or suspected that a fault exists on the appliance it MUST NOT be used until the fault has been rectified by a competant person. 3.3 ELECTRICAL SUPPLY 372mm 580mm 200mm This appliance must be earthed. Supply: 230V - 50Hz fused at 3A. The method of connection to the mains supply must facilitate complete isolation of the appliance. Either a 3A fused three pin plug and unswitched shuttered socket outlet, or a 3A fused double pole switch having a 3mm contact separation in both poles, serving only the boiler (and its external controls), may be used. 3.4 CLEARANCES AND VENTILATION 285mm Wall 1. A flat vertical area is required for the installation of the boiler. 2. Where an open flued (B23) system is used then an air vent must be provided in the same room or internal space of the flue duct air inlet, with a minimum free area of: 2.5 Dimplex 18 = 60cm 2 Dimplex 32 = 125cm 2 3. These dimensions include the necessary clearance around the boiler for case removal, spanner access and air movement. Additional clearances may be required for the passage of pipes around local obstructions such as joists running parallel to the front face of the boiler. 4. When installed in a cupboard or compartment it is not permissible to store other objects in the cupboard. Additionally no flammable objects/items must be allowed to come into contact with the boiler. 5. The boiler does not require additional ventilation when it is installed in a cupboard or compartment. The exception to this is where an open flue system has been installed - See note mm Min For Servicing Purposes 5mm Min In Operation Fig. 11 Dimplex Boilers

6 4.0 ERROR CODES AFTER ENSURING THAT ALL ACTIONS HAVE BEEN CARRIED OUT RESET THE BOILER (REFER TO SECTION 5.4) IF ANY OF THE BELOW FAULTS OCCUR DURING INSTALLATION PLEASE REFER TO THE ACTIONS, HOWEVER IF ANY OTHER ERROR CODE IS SHOWING PLEASE CONTACT THE INSTALLER OR TECHNICAL HELP LINE: RESET LOCK-OUT CODES ERROR CODE DESCRIPTION REASON ACTION RESET POSSIBLE 1 Overheated CH Water temperature Check no air is in heat exchanger / CH system appliance greater than 105 C Check external pump operation Check PCB / X1C connector Check flow thermistor Check wires to sensors not crossed 2 Different check faulty / Sensor temperature Check water pressure Flame for 15 seconds differential incorrect Check external pump / CH system blockage Auto Restart When Fixed Check no air is in heat exchanger / CH system Check flow, and return sensors 3 gas or Lockout flame Low gas pressure. Check gas supply signal / flame, Loss of flame signal during Check gas service cock Lockout after 5 ignition operation Check gas valve and lead attempts Check detection electrode / lead Check PCB / X2A & X2B connectors Check spark generator /spark electrode Check mains earth lead continuity 4 Flue gas sensor / Flue gas temperature greater Check flue sensor flame than 95 C Check flue system Check no air is in heat exchanger / CH system Check external pump Check PCB / PCB connectors BLOCKING CODES ERROR CODE DESCRIPTION REASON ACTION RESET POSSIBLE 5 Defective sensor or Defective flow, return or flue Check wiring to sensors thermal fuse blown sensor or heat exchanger Check PCB / X6 & X8 connectors reached maximum safe working temperature Check flow, return and flue sensors CHECK THERMAL FUSE IS OPEN CIRCUIT. IF SO REPLACE HEAT EXCHANGER (SEE 10.8) 6 Defective gas valve / 5 sec flame signal after burner Check gas valve and lead Flame continues after is switched off Check PCB demand ends 7 Defective fan / flame Missing or Erroneous RPM Check fan signal Check mains fan lead & connector Check low voltage fan lead & connector Check PCB / X3 connector A PCB error / flame Internal error Check PCB b Activate BCC / flame New BCC Turn CH control knob to reset twice to activate C Safety system failure / Failure of internal self Check PCB flame checking system Check BCC is initialised E BCC error / flame Incorrect / missing BCC Reset or replace BCC h flame Faulty connector Check PCB / X1A connector 0 Different check faulty / Water flow rate too low Check water pressure Flame for 15 seconds Check external pump / CH system blockage Check no air is in heat exchanger / CH system Check wires to sensors not crossed Check flow, and return sensors P Error in power supply / Low mains voltage Check mains voltage flame Check PCB connectors light indication Defective power supply Check power supply Check PCB / X1B connector Check PCB fuse Auto Restart When Fixed 6 Dimplex Boilers 2008

7 5.0 ADDITIONAL INFORMATION 5.1 BOILER LOGBOOK The logbook is included inside the Installation instructions. This logbook should be completed by your installer to verify that the correct installation and commissioning procedure was followed. Failure to complete the logbook may result in difficulties should a problem arise with your appliance during the guarantee period. This logbook forms part of the industry s Benchmark code of practice for the installation, commissioning and servicing of central heating systems. All CORGI registered installers carry a CORGI identification card and have a registration number. You can check your installer is registered by telephoning or writing to:- 1 Elmwood Chineham Business Park Crockford Lane Basingstoke RG24 8WG or check online at These appliances meet the requirements of; Gas Appliance Directive 90/396/EEC Efficiency of Hot Water Boilers Directive 92/42/EEC Low Voltage Directive 92/42/EEC Electromagnetic Compatibility Directive 92/31/EEC Type test certified by:- tified Body 0087 (Pin 87BT49). Product/Production certified by: tified Body For GB/IE only. 5.2 GENERAL CARE The front panel should be cleaned with a damp cloth and mild detergent. Do not use abrasive cleaners. 5.3 ROUTINE SERVICING 5.4 EMERGENCY WARNING - If a gas leak is suspected or exists, turn the gas OFF at the incoming mains (adjacent to the meter), Do not operate any electrical switches. Do not operate any electrical appliances. Open all windows and doors. Do not smoke. Extinguish all naked lights. Phone the Transco 24 hour emergency number immediately on (Do not call from a mobile phone). 5.5 PLUMING FROM TERMINAL Like all condensing boilers this appliance will produce a plume of condensation from the flue terminal. This is due to the high efficiency and hence low flue gas temperature of the boiler. It is normal and not a fault indication. The boiler is fitted with a condensate trap. The condensate drain point must not be modified or blocked (see section 7.6 of the installation manual). 5.6 TO TURN THE BOILER OFF For short or long periods Switch the programmer and/or room thermostat switch to the OFF position. NOTE: The appliance is fitted with a frost protection device In the event of very cold conditions. Providing there is mains power supply to the appliance, the frost protection mode is integral. If the system temperature falls below 5 C then the boiler will fire on its minimum setting until a flow temperature of 30 C is reached. Further protection can be incorporated by using a system frost thermostat. The pump will automatically operate for 1 minute in every 24 hours to prevent sticking. 5.7 BOILER OVERHEAT PROTECTION In the event of overheating, the boiler will shut down and the digital display will show 1. Allow the boiler to cool, then briefly turn the CH control knob fully anti-clockwise to the RESET/STANDBY position and then back to ON within two seconds. If the fault persists, consult a CORGI Registered installer. To ensure continued efficient operation of the appliance, it is recommended that it is checked and serviced as necessary at regular intervals. The frequency of servicing will depend upon the particular installation conditions and usage but in general once a year should be adequate. It is law that any service work must be carried out by a competent person such as British Gas or other CORGI Registered personnel. Dimplex Boilers

8 Dimplex Boilers 20/22 First Avenue Bluebridge Industrial Estate Halstead Essex C09 2EX Telephone Sales and Service: Fax: website: Dimplex Boilers is continually improving its products and therefore reserve the right to change product specifications without prior notice. Errors & omissions excepted. SALES AND SERVICE HELPLINE: Part : Issue 1-13/10/08 Dimplex Boilers 2008

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions Performa Gas Fired Wall Mounted Combination Boiler User s Operating Instructions Please keep these instructions safe. Should you move house, please hand them over to the next occupier. Natural Gas Potterton

More information

Baxi Maxflow Combi WM

Baxi Maxflow Combi WM Baxi Maxflow Combi WM Gas Fired Wall Mounted Combination Boiler with Unvented Hot Water Storage Please keep these instructions safe. Should you move house, please hand them over to the next occupier. User

More information

Baxi Maxflow Combi FS

Baxi Maxflow Combi FS Baxi Maxflow Combi FS Gas Fired Floor Standing Combination Boiler with Unvented Hot Water Storage Please keep these instructions safe. Should you move house, please hand them over to the next occupier.

More information

Osprey 2 CFL

Osprey 2 CFL Osprey 2 CFL 125-150 - 180-220 Gas Fired Floor Standing Boiler Users Operating Instructions Please leave these instructions with the user Natural Gas Potterton Osprey 2 CFL 125 G.C.N o 41 590 54 Potterton

More information

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler User s Operating Instructions Baxi System 100 HE Plus Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler Please keep these instructions safe. Should you move house, please hand them

More information

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions Baxi Combi 80Eco Please keep these instructions safe. Should you move house, please hand them over to the next occupier. Gas Fired Wall Mounted Combination Boiler User s Operating Instructions Natural

More information

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER Heat 45 & 55 User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER CE/PI No. 86-CN-69 Heat 45 - GC No. 41-930-40 Heat 55 - GC No. 41-930-41 These instructions

More information

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions User s Operating Instructions Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move

More information

USERS GUIDE 24, 30. For installation guide see reverse of book

USERS GUIDE 24, 30. For installation guide see reverse of book USERS GUIDE 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification

More information

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER System s30 User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER When replacing any part on this appliance, use only spare parts that you can be assured conform to the

More information

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book USERS GUIDE Esprit eco 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification

More information

USER GUIDE LOGIC HEAT H

USER GUIDE LOGIC HEAT H USER GUIDE LOGIC HEAT H 12 15 18 24 30 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not

More information

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017 24 1 2 23 3 4 5 20 6 I 19 7 18 8 9 15 14 11 13 12 i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book i 24 OFF MAX E STATUS BURNER RESET MIN PRE MIN MAX HEAT PREHEAT

More information

USERS GUIDE. LOGIC+ Combi 24, 30, 35

USERS GUIDE. LOGIC+ Combi 24, 30, 35 USERS GUIDE LOGIC+ Combi 24, 30, 35 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use

More information

Logic+ Combi

Logic+ Combi USER GUIDE Logic+ Combi 24 30 35 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use

More information

USER GUIDE VOGUE MAX SYSTEM

USER GUIDE VOGUE MAX SYSTEM USER GUIDE VOGUE MAX SYSTEM 15 18 26 32 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not

More information

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book USER GUIDE IMAX XTRA EL 320-620kW For Installation Guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance

More information

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on You can rely on User Guide and Important Warranty Information Suprima HE Range Condensing Central Heating Boiler Please keep these instructions in a safe place. If you move house, please hand them over

More information

With a power output ranging from 13kW to 24kW, they provide the flexible answer for the majority of traditional installation scenarios.

With a power output ranging from 13kW to 24kW, they provide the flexible answer for the majority of traditional installation scenarios. Alpha Regular Boilers CDR Range CDR heating-only boilers are for use on open-vented or using the Alpha sealed system kit sealed systems. When fitted with a storage cylinder, they are capable of supplying

More information

User's Instructions. Alpha CB50

User's Instructions. Alpha CB50 User's Instructions Alpha CB50 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boiler with Unvented Hot Water Storage (From Boiler Serial No. 27B32500001) For Technical help or for Service

More information

GB24 & GB30. User Manual

GB24 & GB30. User Manual GB24 & GB30 User Manual BOILER OUTPUT To Domestic Hot Water:To Central Heating: GB24/30 Minimum 8.0 kw (27,296 Btu/h) GB24 Maximum 24.2 kw (82,570 Btu/h) GB30 Maximum 30.3 kw (103,384 Btu/h) GB24/30 Minimum

More information

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40 USER GUIDE VOGUE COMBI GEN2 C26 C32 C40 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not

More information

/2005 GB(EN) For the user. Wall-mounted condensing gas combi boiler Buderus /C, /C

/2005 GB(EN) For the user. Wall-mounted condensing gas combi boiler Buderus /C, /C 7215 3500-02/2005 GB(EN) For the user Users manual Wall-mounted condensing gas combi boiler Buderus 500-24/C, 500-28/C Please read thoroughly before operating the unit Introduction Please read these instructions

More information

Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier.

Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. User s Operating Instructions & Important Warranty Information Baxi Combi 1 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions

More information

Format System 25 HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Format System 25 HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty UK ENSURE THAT THESE INSTRUCTIONS ARE LEFT FOR THE USER AFTER COMPLETION OF THE BENCHMARK SECTION Format System 25 HE User instructions 199838 Please read the Important Notice within this guide regarding

More information

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES 24-28Si II SERIES G.C. NUMBERS APPLIANCE NATURAL GAS L.P.G. 24Si II 47 311 65 47 311 66 28Si II 47 311 67 47 311 68 USER INSTRUCTIONS & CUSTOMER CARE GUIDE EXCELLENCE COMES AS STANDARD CONTENTS Page No.

More information

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions GB PLEASE LEAVE THIS INSTRUCTION WITH THE USER Ecomfort 30 HE User instructions CONTENTS OPERATING INSTRUCTIONS FOR THE USER 1.1 INTRODUCTION.................................................................................

More information

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions Baxi Bahama 100 Please keep these instructions safe. Should you move house, please hand them over to the next occupier. Gas Fired Wall Mounted Combination Boiler User s Operating Instructions Natural Gas

More information

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers User's Instructions Alpha CD24C/32C Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers For Technical help or for Service call... ALPHA HELPLINE

More information

iheat 25c iheat 30c iheat 35c

iheat 25c iheat 30c iheat 35c iheat 25c iheat 30c iheat 35c Combination Condensing Boilers User Instructions G.C. NUMBER iheat 25c N 47-260-16 iheat 30c N 47-260-17 iheat 35c N 47-260-18 These instructions should be left with the user

More information

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice Vote for your Installer of the year at www.worcester-bosch.co.uk 9/14, 14/19 & 19/24CBi Worcester supports the Benchmark code of practice G. C. NUMBERS APPLIANCE NATURAL GAS LPG 9/14CBi 41 311 50 41 311

More information

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions GB PLEASE LEAVE THIS INSTRUCTION WH THE USER ECOMFORT PLUS 25 HE User instructions All descriptions and illustrations provided in this manual have been carefully prepared but we reserve the right to make

More information

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit 7215 3200-02/2006 GB (EN) For the user Users Manual Gas wall hung Boiler condensing Buderus 500-24/S Please read thoroughly before operating the unit Introduction Please read these instructions and follow

More information

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel: 0020051423-02 10.07 British Gas 330+ High Efficiency Condensing Boiler Instructions for Use To b e l e f t w i t h t h e u s e r British Gas Service Tel: 0845 9500400 WARNING GAS LEAK OR FAULT Turn off

More information

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe.

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe. User Guide and Important Warranty Information Suprima 30-80 HE Condensing Central Heating Boiler Please read this document and keep it safe. It will help you out should your boiler need attention. Introduction

More information

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER Combi C30 & C35 User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER When replacing any part on this appliance, use only spare parts that you can be assured confirm

More information

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers User's Instructions Alpha CD5X/8X Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers For Technical help or for Service call... ALPHA HELPLINE Tel:

More information

MURELLE EV HE 25/55-30/55

MURELLE EV HE 25/55-30/55 UK ENSURE THAT THESE INSTRUCTIONS ARE LEFT FOR THE USER AFTER COMPLETION OF THE BENCHMARK SECTION MURELLE EV HE 25/55-30/55 User instructions 199838 Please read the Important Notice within this guide regarding

More information

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r. Ultracom hxi High Efficiency Condensing System Boilers Instructions for Use To b e l e f t w i t h t h e u s e r WARNING GAS LEAK OR FAULT Turn off the gas emergency control valve immediately. Eliminate

More information

2 Minimiser SE - User's

2 Minimiser SE - User's 2 Minimiser SE - User's Minimiser SE (Natural Gas Models Only) Minimiser SE G.C. Appliance No. Minimiser SE G.C. Appliance No. 30 41 349 64 40... 41 349 65 50... 41 349 66 60... 41 349 67 70... 41 349

More information

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r. Ultracom cxi High Efficiency Condensing System Boilers Instructions for Use To b e l e f t w i t h t h e u s e r WARNING GAS LEAK OR FAULT Turn off the gas emergency control valve immediately. Eliminate

More information

MERIDIAN HE 30 C. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

MERIDIAN HE 30 C. User instructions. Please read the Important Notice within this guide regarding your boiler warranty UK ENSURE THAT THESE INSTRUCTIONS ARE LEFT FOR THE USER AFTER COMPLETION OF THE BENCHMARK SECTION MERIDIAN HE 30 C 199838 User instructions Please read the Important Notice within this guide regarding

More information

WARMCAIR. Condensing Air & Water Heater. High Efficiency Downflow Condensing Air & Water Heater USERS INSTRUCTIONS

WARMCAIR. Condensing Air & Water Heater. High Efficiency Downflow Condensing Air & Water Heater USERS INSTRUCTIONS WARMCAIR Condensing Air & Water Heater Publication No. ZZ 1449-2 September 2016 High Efficiency Downflow Condensing Air & Water Heater USERS INSTRUCTIONS Warmcair C10DW - G.C. No. 43-417-59 Warmcair C16DW

More information

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty UK ENSURE THAT THESE INSTRUCTIONS ARE LEFT FOR THE USER AFTER COMPLETION OF THE BENCHMARK SECTION FORMAT DGT HE 199838 User instructions Please read the Important Notice within this guide regarding your

More information

condens Instructions for Use Betacom 2 24 G.C. No Betacom 2 28 G.C. No

condens Instructions for Use Betacom 2 24 G.C. No Betacom 2 28 G.C. No condens Instructions for Use Betacom 2 24 G.C. No. 47-019-16 Betacom 2 28 G.C. No. 47-019-17 table of contents READ CAREFULLY BEFORE USING 1 Read me...3 1.1 Welcome... 3 1.2 Guarantee Pack... 3 1.3 Servicing...

More information

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No. Ultracom 2 sxi Instructions for Use To be left with the user 12sxi G.C. No. 41-019-12 18sxi G.C. No. 41-019-13 30sxi G.C. No. 41-019-14 High Efficiency Condensing System Boilers www.glow-worm.co.uk TABLE

More information

Powermax HE 85, 115 & 150 Litre Condensing Boilers with Integrated Hot Water Storage

Powermax HE 85, 115 & 150 Litre Condensing Boilers with Integrated Hot Water Storage User s Instructions Quick Guide to the Controls When the Powermax was installed, the Installer should have - left or given you these and other instructions including the Benchmark Log Book and Potterton

More information

24CDi, 28CDi & 35CDi II COMBI

24CDi, 28CDi & 35CDi II COMBI Vote for your Installer of the year at www.worcester-bosch.co.uk 24CDi, 28CDi & 35CDi II COMBI Worcester supports the Benchmark code of practice G.C. NUMBERS APPLIANCE NATURAL GAS L.P.G. 24CDi Fanned Flued

More information

USER INSTRUCTIONS & CUSTOMER CARE GUIDE HIGHFLOW 400 ELECTRONIC SERIES

USER INSTRUCTIONS & CUSTOMER CARE GUIDE HIGHFLOW 400 ELECTRONIC SERIES HIGHFLOW 400 ELECTRONIC SERIES G.C. NUMBERS APPLIANCE NATURAL GAS L.P.G. Fanned Flue (RSF) 47 311 61 47 311 64 Balanced Flue (BF) 47 311 62 Open Flue (OF) 47 311 63 USER INSTRUCTIONS & CUSTOMER CARE GUIDE

More information

Combi Eco Elite Range. User s Guide and Important Warranty Information

Combi Eco Elite Range. User s Guide and Important Warranty Information User s Guide and Important Warranty Information Combi Eco Elite Range Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Baxi Heating UK Ltd

More information

Mikrofill Ethos Condensing combination boiler

Mikrofill Ethos Condensing combination boiler Mikrofill Ethos Condensing combination boiler User Instructions 24cc CE Mark Mikrofill gas appliances comply with the requirements contained in CE Mark documents contained with European directives applicable

More information

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler User s Operating Instructions Baxi Combi 05 HE Gas Fired Wall Mounted Condensing Boiler Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Contents

More information

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler User s Operating Instructions & Important Warranty Information Baxi Megaflo System HE IE Range Gas Fired Wall Mounted Condensing Boiler Please keep these instructions in a safe place. If you move house,

More information

Linea HE. High efficiency combi boiler. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Linea HE. High efficiency combi boiler. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Linea HE High efficiency combi boiler Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Vokèra is a licensed member of the Benchmark scheme which aims to improve the standards of installation

More information

The guarantee on this appliance is valid for 12 months from the first day of installation.

The guarantee on this appliance is valid for 12 months from the first day of installation. Users Manual Dear Customer, Thank you for choosing an ARISTON boiler. We guarantee that your boiler is a reliable and technically sound product. This Users Manual provides detailed instructions and recommendations

More information

Dimplex 18 OV Dimplex 32 OV

Dimplex 18 OV Dimplex 32 OV 751287 OV MANUAL 19/10/10 08:46 Page 1 Glen Dimplex Boilers Stoney Lane Prescot Merseyside. L35 2XW For all telephone enquiries call: 0844 371 2222 Dimplex 18 OV Dimplex 32 OV Open Vented Condensing Boilers

More information

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE DANESMOOR FRONT SERVICE (FS) 12-18, 18-25 FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE EXCELLENCE COMES AS STANDARD Thank you for purchasing a Danesmoor Front Servicing

More information

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler You can rely on User Guide and Important Warranty Information Promax System HE Plus A Range Condensing System Boiler Please keep these instructions in a safe place. If you move house, please hand them

More information

User Guide and Important Warranty Information Condensing Central Heating Boiler

User Guide and Important Warranty Information Condensing Central Heating Boiler User Guide and Important Warranty Information Condensing Central Heating Boiler Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Baxi Heating

More information

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler 0 4 You can rely on User Guide and Important Warranty Information Performa 4 Eco HE Condensing Combination Boiler Please keep these instructions in a safe place. If you move house, please hand them over

More information

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL STREBEL GENEVA CE ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL INDEX TABLE 1 TECHNICAL DATA SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 SECTION 6 SECTION 7 SECTION 8 SECTION

More information

AquaNova. Water heater. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

AquaNova. Water heater. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER AquaNova Water heater Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Vokèra is a licensed member of the Benchmark scheme which aims to improve the standards of installation and commissioning

More information

Maximiser SE. USER S INSTRUCTIONS Natural gas only INSTALLER: TELEPHONE:

Maximiser SE. USER S INSTRUCTIONS Natural gas only INSTALLER: TELEPHONE: Maximiser SE USER S INSTRUCTIONS Natural gas only INSTALLER: TELEPHONE: 705.276A-3233 11-2000 INTRODUCTION It is essential that the instructions in this booklet are strictly followed, for safe and economic

More information

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, 50-70 FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE EXCELLENCE COMES AS STANDARD Thank you for purchasing a Danesmoor

More information

Operating instructions

Operating instructions The energy you need Operating instructions Betacom 3 24c -A (H-GB) 30c -A (H-GB) GB, IE Contents Contents 1 Safety... 3 1.1 Action-related warnings... 3 1.2 Intended use... 3 1.3 General safety information...

More information

Vote for your Installer of the year at HEATSLAVE

Vote for your Installer of the year at   HEATSLAVE Vote for your Installer of the year at www.worcester-bosch.co.uk HEATSLAVE 12/14, 15/19, 20/25, 26/32 FLOOR-STANDING OIL-FIRED COMBINATION BOILERS FOR CENTRAL HEATING AND MAINS-FED DOMESTIC HOT WATER USER

More information

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions. User Manual for model FLOWMAX-90 Condensing water heater 85,000 BTU WARNING If the information in these instructions is not followed exactly, a fire or explosion may result, causing property damage, personal

More information

Operating instructions

Operating instructions Operating instructions Capriz 2 24c 28c GB, IE Contents Contents 1 Safety... 3 1.1 Action-related warnings... 3 1.2 Intended use... 3 1.3 General safety information... 4 2 Notes on the documentation...

More information

VIESMANN. Operating instructions VITODENS 100-W. for the system user

VIESMANN. Operating instructions VITODENS 100-W. for the system user Operating instructions for the system user VIESMANN Heating system with control unit for constant temperature or weather-compensated mode VITODENS 100-W 1/2012 Please keep safe. Safety instructions For

More information

Statesman 45/50L, 50/70L, 70/90L, 90/110L, Utility 50/70L, 70/90L, 90/110L, 110/130L, 130/150L

Statesman 45/50L, 50/70L, 70/90L, 90/110L, Utility 50/70L, 70/90L, 90/110L, 110/130L, 130/150L Users Instructions Statesman 45/50L, 50/70L, 70/90L, 90/110L, Utility 50/70L, 70/90L, 90/110L, 110/130L, 130/150L About the Boiler About Safety This is a Floor Standing, Horizontally Fired, Automatic Pressure

More information

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI For the owner Operating manual ecotec plus 937 Gas condensing storage combination boiler GB VUI Contents Appliance characteristics Recommended accessories Contents Appliance characteristics... Recommended

More information

User Guide. Promax SL Condensing Central Heating Boiler

User Guide. Promax SL Condensing Central Heating Boiler United Kingdom en User Guide Condensing Central Heating Boiler Promax SL 12-15 - 18-24 Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Contents

More information

condens Instructions for Use Ultracom 2 35 Store G.C. No

condens Instructions for Use Ultracom 2 35 Store G.C. No condens Instructions for Use Ultracom 2 35 Store G.C. No. 47-019-15 table of contents READ CAREFULLY BEFORE USING 1 Read me...3 1.1 Welcome... 3 1.2 Guarantee Pack... 3 1.3 Servicing... 3 1.4 Benchmark...

More information

Alpha CD13R,18R and 24R

Alpha CD13R,18R and 24R Installation and Servicing Instructions Alpha CD3R,8R and 24R Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Regular Boiler Range For Technical help or for Service call...

More information

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A cod. 6272262A GENERAL DATA Heating Data Heat Output Input (Adjustable) (Adjustable) Format 34i 11.2 34KW 45 145MJ/hr Format 34e 11.2 34KW 45 145MJ/hr General Specifications FORMAT 34i 34e Main burner injectors

More information

Users manual. Buderus /29/43/60 and Buderus T25/29T25 H/V. Wall-mounted condensing gas boiler. For the user

Users manual. Buderus /29/43/60 and Buderus T25/29T25 H/V. Wall-mounted condensing gas boiler. For the user Users manual Wall-mounted condensing gas boiler Buderus 800-24/29/43/60 and Buderus 800-24T25/29T25 H/V For the user Please read thoroughly before operating the unit 722 3700 (03/200) GB Preface Introduction

More information

Induction Fryer. Instruction manual. Model Modèle Modell Modello Modelo Malli: CP793

Induction Fryer. Instruction manual. Model Modèle Modell Modello Modelo Malli: CP793 Induction Fryer Instruction manual Model Modèle Modell Modello Modelo Malli: CP793 UK Safety Tips Position on a flat, stable surface. A service agent/qualified technician should carry out installation

More information

INSTALLATION AND MANINTENANCE INSTRUCTIONS

INSTALLATION AND MANINTENANCE INSTRUCTIONS INSTALLATION AND MANINTENANCE INSTRUCTIONS Appr. Nr. A 9503 T - 0085 AQ 0765 PEGASUS F2 T HIGH EFFICIENCY GAS-FIRED CAST-IRON BOILERS Models 51-68 - 85-102 2 Contents 1. General technical data 2. Dimensional

More information

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer

More information

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO Great Britain en Installation, user and service manual Control panel HMI Gas 310/610 ECO PRO Dear Customer, Thank you very much for buying this appliance. Please read through the manual carefully before

More information

DOMESTIC HOT WATER Follow operational sequence

DOMESTIC HOT WATER Follow operational sequence DOMESTIC HOT WATER Follow operational sequence Turn Winter/Summer selector to Summer position. The display is switch on. Go to section A Error 110 flashing Error 131 flashing Turn the selector to reset

More information

Greenstar 12i/24i System

Greenstar 12i/24i System USER INSTRUCTIONS & CUSTOMER CARE GUIDE Greenstar 12i/24i System WALL HUNG GAS-FIRED CONDENSING SYSTEM BOILER FOR SEALED CENTRAL HEATING SYSTEMS & INDIRECT FED DOMESTIC HOT WATER THIS BOILER IS USED WITH

More information

Osprey 2 CFL

Osprey 2 CFL Osprey 2 CFL 125-150 - 180-220 Gas Fired Floor Standing Boiler Installation and Servicing Instructions Please leave these instructions with the user Natural Gas Potterton Osprey 2 CFL 125 G.C.N o 41 590

More information

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation Operating instructions for system users VIESMANN Heating system with control unit for constant temperature operation VITODENS 100 2/2005 Please keep safe Safety instructions For your safety Please follow

More information

User Guide. Main Eco Elite Combi Condensing Central Heating Boiler

User Guide. Main Eco Elite Combi Condensing Central Heating Boiler United Kingdom en User Guide Condensing Central Heating Boiler Main Eco Elite Combi 5-0 Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Contents

More information

Combi 24 Combi 30 Combi 38

Combi 24 Combi 30 Combi 38 8pp MANUAL SPREADS 9// 8:6 Page Glen Dimplex Boilers Stoney Lane Prescot Merseyside. L5 XW For all telephone enquiries call: 8 7 Combi Combi Combi 8 Combination Condensing Boilers website: www.glendimplexboilers.com

More information

E-COMBI EVO E-SYSTEM EVO

E-COMBI EVO E-SYSTEM EVO E-COMBI EVO E-SYSTEM EVO User s manual CONDENSING WALL-HUNG GAS BOILER G.C.N.:47-116-68 (24 kw) G.C.N.:47-116-69 (30 kw) G.C.N.:47-116-70 (38 kw) G.C.N.:41-116-39 (24 kw) G.C.N.:41-116-40 (30 kw) Country

More information

INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS BG 2000-S (V13) RU PL DE IT ES NL EN 1 662Y0600 A

INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS BG 2000-S (V13) RU PL DE IT ES NL EN 1 662Y0600 A INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS G 2000-S 25-35 - 45-55 60-70 - 100 (V13) 1 Index WARNINGS GAS FLOW RATE DIMSIONS SETTINGS PARAMETERS SERVICING THE URNER 3 8 13 OPERATING DESCRIPTION

More information

FEB-24E UK SUPERCOMPACT COMBINATION BOILER USER MANUAL

FEB-24E UK SUPERCOMPACT COMBINATION BOILER USER MANUAL FEB-24E UK SUPERCOMPACT COMBINATION BOILER USER MANUAL Morco Products Ltd Riverview Road, Beverley, East Yorkshire, HU17 0LD Telephone 01482 325456 Fax 01482 212869 1 2 CONTENTS Section Page 1 USERS INSTRUCTIONS

More information

User Guide. EcoBlue Advance Heat Gas Fired Wall Mounted Condensing Boiler

User Guide. EcoBlue Advance Heat Gas Fired Wall Mounted Condensing Boiler United Kingdom en User Guide Gas Fired Wall Mounted Condensing Boiler EcoBlue Advance Heat 13-16 - 19-25 - 30 Please keep these instructions in a safe place. If you move house please hand them over to

More information

MHG201 Gas Hob Manual for Installation, Use and Maintenance

MHG201 Gas Hob Manual for Installation, Use and Maintenance MHG201 Gas Hob Manual for Installation, Use and Maintenance 1 Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu

More information

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Contact Details. Please note that some of the contact details on this PDF document may not be current. Contact Details Please note that some of the contact details on this PDF document may not be current. Please use the following details if you need to contact us: Telephone: 0844 879 3588 Email: customer.services@gdcgroup.co.uk

More information

24/30/38. E-Combi. CONDENSING WALL HUNG COMBINATION BOILER G.C.N : (24 kw) G.C.N : (30 kw) G.C.N : (38 kw)

24/30/38. E-Combi. CONDENSING WALL HUNG COMBINATION BOILER G.C.N : (24 kw) G.C.N : (30 kw) G.C.N : (38 kw) E-Combi 24/30/38 E-System 24/30 CNDENSNG WALL HUNG CMBNATN BLER G.C.N : 47-11 - 2 (24 kw) G.C.N : 47-11 - 3 (30 kw) G.C.N : 47-11 - 4 (38 kw) CNDENSNG WALL HUNG.H. BLER G.C.N : 41-11 - 34 (24 kw) G.C.N

More information

Operating instructions

Operating instructions Operating instructions For the operator Operating instructions HOME SYSTEM GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Tel. +49 21 91 18 0 Fax +49 21 91 18 28 10 info@vaillant.de

More information

Q - Series Boiler. Troubleshooting Manual

Q - Series Boiler. Troubleshooting Manual Q - Series Boiler Troubleshooting Manual WARNING There are a number of live tests that are required when fault finding this product. Extreme care should be used at all times to avoid contact with energized

More information

Baxi Bermuda Inset 3 Super

Baxi Bermuda Inset 3 Super Baxi Bermuda Inset 3 Super Fireside Gas Central Heating Units Please keep these instructions safe. Should you move house, please hand them over to the next occupier. User s Operating Instructions TS, BS,

More information

Installation & Service Instructions Suprima HE Condensing Central Heating Boiler

Installation & Service Instructions Suprima HE Condensing Central Heating Boiler Installation & Service Instructions Suprima 30-80 HE Condensing Central Heating Boiler Only a flue approved for the Suprima HE can be used. Contents 1. Introduction...3 2. Technical Data...4 3. Installation

More information

Installation & Service Instructions. Suprima 30-80

Installation & Service Instructions. Suprima 30-80 See inside cover for models covered by these instructions Installation & Service Instructions Suprima 30-80 Wall Mounted Fan Assisted Balanced Flue Gas Boilers THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS

More information

GREENSTAR HIGHFLOW 440/550CDi

GREENSTAR HIGHFLOW 440/550CDi FLOOR STANDING RSF GAS-FIRED CONDENSING COMBINATION BOILER GREENSTAR HIGHFLOW 440/550CDi FOR SEALED CENTRAL HEATING SYSTEMS AND MAINS FED DOMESTIC HOT WATER THE APPLIANCE IS FOR USE WITH NATURAL GAS OR

More information

VIESMANN. Operating instructions VITODENS 111-W. for the system user

VIESMANN. Operating instructions VITODENS 111-W. for the system user Operating instructions for the system user VIESMANN Heating system with control unit for constant temperature or weather-compensated mode VITODENS 111-W 4/2012 Please keep safe. Safety instructions For

More information