Mini Duct Heating and Air Conditioning Indoor Air Quality Systems. July Featuring: Also Including: Lo-Velocity Systems JH Fancoils
|
|
- Russell Russell
- 6 years ago
- Views:
Transcription
1 Mini Duct Heating and Air Conditioning Indoor Air Quality Systems July 2008 Parts List Featuring: TM Also Including: Lo-Velocity Systems JH Fancoils Minimum Invoice Amount of $25 Net in Effect ESP b
2 Hi-Velocity Systems Hi-Velocity Heating Fancoils Hi-Velocity Fancoils with EPC Motors c/w 6 Row Water Coil Weight Shipping Dimensions HE-50 H 86 37/19/ HE-70 H /19/ HE-100 H /19/ Hi-Velocity Blower Units Hi-Velocity Blower Units with EPC Motors Weight Shipping Dimensions HE-50 BU 72 37/19/ HE-70 BU 82 37/19/ HE-100 BU /19/ Pre-Piped TX Cooling Modules Weight Shipping Dimensions RPM-E /15/22 RPM-E /15/22 RPM-E /19/17 w/ R-22 TXV w/ R410a TXV (on request) Note: RPM-E-100 is for applications 3.5 to 5.0 tons TX Cooling Modules Weight Shipping Dimensions RCM /11/19 RCM /11/19 RM /8/20 RM /8/20 w/ R-22 TXV w/ R410a TXV (on request) Water Coil Modules Weight Shipping Dimensions WCM /11/ WCM /11/ WM /8/ Pg. 1
3 Heating Hot Water Coils 6 Row Heating Coils (For the HE, HV Fan Coils) Weight Shipping Dimensions HE/HV /6/ HE/HV /6/ HE/HV /6/ *Quote Fan Coil Serial number if ordering replacement coil. Electrical Strip Coil Add-on For HE - 50BU Weight Shipping Dimensions HV KW 21 18/13/ HV KW 21 18/13/ HV KW 21 18/13/ For HE - 70BU Weight Shipping Dimensions HV KW 27 18/13/ HV KW 27 18/13/ HV KW 27 18/13/ HV KW 27 18/13/ For HE BU Weight Shipping Dimensions HV KW 28 18/13/ HV KW 28 18/13/ HV KW 28 18/13/ HV KW 28 18/13/ HV KW 28 18/13/ Pg. 2
4 Flexible Duct AFD - Assembled Flex Duct UFD - Unassembled Flex Duct R4.2 Insulation 2 Flexible Duct (Sold in carton quantity only) Weight Shipping Dimensions 2 X 10 AFD (4/carton) 12 15/15/ X 15 AFD (4/carton) 18 15/15/ X 25 UFD (1/carton) 8 10/10/ R8.4 Insulation Weight Shipping Dimensions 2 X 10 AFD (2/carton) 10 15/15/ X 15 AFD (2/carton) 15 15/15/ X 25 UFD (1/carton) 12 15/15/ R4.2 Insulation R4.2 insulation HE Flexible Duct (Sold in carton quantity only) Weight Shipping Dimensions HE X 10 AFD (2/carton) 7 27/12/ HE X 15 AFD (2/carton) 11 26/15/ HE X 25 UFD (1/carton) /12/ R8.4 Insulation Weight Shipping Dimensions HE X 10 AFD (1/carton) 6 27/10/ HE X 15 AFD (1/carton) 10 25/15/ HE X 25 UFD (1/carton) 15 35/15/ Plenum Duct Insulsleeve 6 X 10 Insulsleeve X 10 Insulsleeve X 10 Insulsleeve R8.4 Insulation 6 X 10 Insulsleeve X 10 Insulsleeve X 10 Insulsleeve Pg. 3
5 Duct Accessories 2 Accessories ) AFD Kit (Rough-In Boot, White Plastic Vent Plate, Branch Take-Off, Rough-In Cap) ) UFD KIT (Branch Connector Tube, Branch Coupler, Cable Tie) ) Vent Plate Collar ) Branch Take-off c/w Gasket ) Branch Take-off Gasket ) Branch Coupler ) Branch Connector Tube ) Rough-In Kit (Rough-In Boot, Rough-In Cap) ) Rough-In Cap ) Rough-In Cap ) Vent Extender Kit (Branch Connector Tube, Vent Plate Collar) ) Vent Plate Key ) Vent Plate Gasket ) Beauty Ring HE Accessories 1) AFD Kit (Rough-In Boot, White Plastic Vent Plate, Branch Take-Off, Rough-In Cap) ) Vent Plate Collar ) Branch Take-off c/w Gasket ) Branch Take-off Gasket ) Branch Coupler ) Branch Connector Tube ) Rough-In Kit (Rough-In Boot, Rough-In Cap) ) Rough-In Cap ) Rough-In Cap ) Vent Extender Kit (Branch Connector Tube, Vent Plate Collar) ) Vent Plate Key ) HE Connector Tube - 4 length (5 lengths per bundle) Pg. 4
6 Outlet Vent Plates 1. Grid Insert (Included with Vent Plate) (N/C) HE (N/C) Louvered Insert (N/C) HE (N/C) 2 HE 1) White Plastic w/ Snap-In Grill HE 2) Brushed Chrome ) Brite Chrome HE 4) Polished Brass ) Antique Brass HE 6) Copper Vein ) Silver Vein ) Black Wrinkle HE 9) Unfinished Oak ) Unfinished Maple *Special Order Vent Plates may not be exactly as shown. Pg. 5
7 Hi-Velocity Air Purification System HE PS Hi-Velocity Air Purification System - One Size Fits All Weight Shipping Dimensions HE PS c/w MERV 11 Filter 31 29/21/ HE PS Replacement Parts HE PS One Year Service Kit c/w two Merv 11 Filters and two UV Lamps Replacement UV Lamps (2/pkg) Replacement MERV 11 Filter Optional MERV 14 Filter Electronic Lamp Ballast Volt Transformer Titanium/Honeycomb Catalyst Pg. 6
8 Accessories PWM (Pulse Width Modulation) Zoning Control Kit PWM Kit Filter Racks (with filter) Weight Shipping Dimensions FR /4/ FR /4/ FR /4/ Replacement Filters FR/RA-50 (14 X 18 ) FR/RA-70 (18 X 18 ) FR/RA-100 (18 X 24 ) FR/RA-140 (24 X 26 ) Return Air Base (with built-in filter rack and filter) Weight Shipping Dimensions RA /5/ RA /5/ RA /5/ Hanging Strap Kit Hanging Strap Kit Pg. 7
9 Replacement Parts Serial Number and Model Number must be supplied when ordering replacement parts. EPC Motors (For Hi-Velocity-HE Units) Motors HE - Motor (All Models) PSC Motors (For Hi-Velocity-HV Units) HV-50/51/ HV-70/ HV-100/ HV Blower (For Hi-Velocity-HE/HV Units) HE/HV-50/51/ HE/HV-70/ HE/HV-100/ HV For Hi-Velocity-HE Fancoils with EPC Motors Blowers Circuit Boards EPC Circuit Board w/o Transformer For Hi-Velocity-HV Fancoils with PSC Motors PSC Circuit Board EPC Transformer For Hi-Velocity-HE Fancoils with EPC Motors EPC Transformer (HE) Control Boards For Hi-Velocity-HE Fancoils with EPC Motors EPC Control Board Pg. 8
10 1. 2. Replacement Parts R-22 Thermal Expansion Valves (Heat pump ready) 1.5 Ton TX Valve Ton TX Valve Ton TX Valve Ton TX Valve Ton TX Valve R-410a Thermal Expansion Valves (Heat pump ready) 1.5 Ton TX Valve Ton TX Valve Ton TX Valve Ton TX Valve Ton TX Valve Refrigerant Accessories (Can be used with R-22 & R-410a refrigerants) Refrigerant Components 3/8 Sweat Site Glass /4 Access Valve Stem /8 Access Valve Stem Heat Pump Check Valve Electrical Components 1) 5 AMP Rheostat ) 10 AMP Rheostat ) PSC Transformer (HV) ) HV - 50 Capacitor ) HV - 70/100/140 Capacitor ) Fixed Temp Freeze Stat ) Low Ambient Cut-Out ) Slo-blo Fuse ) Turbo Meter Sequencer-TH Relay 30A/24VAC Water Components DHW Heating Circulator Replacement Cartridge /2 Non-Electric Valve Body /4 Non-Electric Valve Body Non-Electric Valve Body Air Sensor for Valve Body Pg. 9
11 HE Product Notes All HE units come complete with painted insulated cabinet, fan and 115/230/1/50/60 EPC Motor, pre-wired circuit board c/w heat/cool/dehumidification/constant fan/auxiliary relays, timer circuit. HE Heating (H) units are manufactured with six row water coils. All units are packaged with two vent plate keys. RCM/RPM/WCM coil modules come complete with 2-7 /8 FIP drain pan connections (primary/secondary). RM/WM coil modules come complete with ½ PVC drain pan connections. RCM/RPM/RM coil modules come complete with drain pan, freeze stat, site glass, two Schrader valves and expansion valve in either R22 or R410a refrigerant. Expansion valves are heat pump ready with a built in check valve. RPM-E Modules are pre-assembled with components as described above in either R22 or R410a refrigerant. 2 and HE AFD (Assembled Flex Duct) includes 10 or 15 of flexible duct as specified plus one foot, two BC (Branch Couplers) attached, one BTO (Branch Take-Off with Gasket) assembly, one Rough-In Kit, one Rough-In Cap, and one Plastic Vent Plate. 2 UFD (Unassembled Flex Duct) includes 25 of flexible duct and one UFD Kit (Three Branch Connector Tubes, six Branch Couplers, and six tie wraps. HE UFD includes 25 of flexible duct, six BCTs and six tie wraps. Filter Racks and Return Air Bases come with Filter. Return Air Bases are acoustically lined and require field assembly. Insulsleeve is a R4.2 (2 insulation) or R8.4 (4 insulation) vapor barrier to be slid over 6, 8 or 10 rigid metal duct. 2 and HE Rough-In Cap extension is designed for gypcrete floors. Vent Plate Extender Kit includes one 6 BCT and one Vent Plate Collar. All measurements are Imperial (Inch-Pound). To ensure ongoing product improvements, Energy Saving Products reserves the right to change any product without notice. Pg. 10
12 Lo-Velocity & JH Systems Lo-Velocity Heating Fancoils (Supplied Standard with 6 Row Coil) Weight Shipping Dimensions LV-50 H 70 37/19/ LV-70 H 94 37/19/ LV-120 H /19/ LV-140 H /19/ Lo-Velocity Blower Units Weight Shipping Dimensions LV-50 BU 53 37/19/ LV-70 BU 74 37/19/ LV-120 BU 85 37/19/ LV-140 BU 87 37/19/ JH Fan Coils JH Units & Systems Weight Shipping Dimensions JH /16/ JH /16/ JH Exhaust Air Units Weight Shipping Dimensions JH-15 EX 25 25/16/ JH-30 EX 32 25/16/ JH Northern Pak Fan Coils Weight Shipping Dimensions JH-15 NP 33 25/16/ JH 30 NP 40 25/16/ JH Full Northern Pak Fan Coils Weight Shipping Dimensions JH-15 NPF 49 25/16/ JH-30 NPF 56 25/16/ Northern Pak Includes 1/2 Non-Electric Valve Body Air Sensor for Valve Body RheoStat Low Ambient Cut-Out Hanging Strap Kit Pg. 11 Full Northern Pak Includes Fresh Air Damper Section 1/2 Non-Electric Valve Body Air Sensor for Valve Body RheoStat Low Ambient Cut-Out Hanging Strap Kit
13 Coil Modules Pre-Piped TX Cooling Modules Weight Shipping Dimensions RPM-E /15/22 RPM-E /15/22 RPM-E /19/17 Note: RPM-E-100 is for applications 3.5 to 5.0 tons w/ R-22 TXV w/ R410a TXV (on request) TX Cooling Modules w/ R-22 TXV w/ R410a TXV (on request) Weight Shipping Dimensions RCM /11/19 RCM /11/19 RM /8/20 RM /8/ Water Coil Modules Weight Shipping Dimensions WCM /11/ WCM /11/ WM /8/ JH Heating Coils Hot Water Coils Weight Shipping Dimensions JH 15/ /7/ Row Heating Coils Weight Shipping Dimensions LV /6/ LV /6/ LV-100/ /6/ Pg. 12
14 R-22 Thermal Expansion Valves (Heat pump ready) 1.5 Ton TX Valve Ton TX Valve Ton TX Valve Ton TX Valve Ton TX Valve R-410a Thermal Expansion Valves (Heat pump ready) 1.5 Ton TX Valve Ton TX Valve Ton TX Valve Ton TX Valve Ton TX Valve Refrigerant Accessories (Can be used with R-22 & R-410a refrigerants) Replacement Parts Refrigerant Components 3/8 Sweat Site Glass /4 Access Valve Stem /8 Access Valve Stem Heat Pump Check Valve Water Components & Misc. s DHW Heating Circulator Replacement Cartridge /2 Non-Electric Valve Body /4 Non-Electric Valve Body Non-Electric Valve Body Air Sensor for Valve Body JH Series 6 Supply Collar JH Series 8 Supply Collar JH Series 6 Return Collar JH Series 8 Return Collar JH Series Directional Vanes (Set of 4) Electrical Components 1) 5 AMP Rheostat ) 10 AMP Rheostat ) Transformer ) LV-50/70/120 Capacitor ) LV-140 Capacitor ) Fixed Temp Freeze Stat ) Low Ambient Cut-Out ) Slo-blo Fuse Pg. 13
15 Replacement Parts & Accessories Circuit Boards PSC Circuit Board PSC Motors (For Lo-Velocity Units) LV-50/70/120 Motor LV-140 Motor JH-15 Motor & Blower Assembly JH-30 Motor & Blower Assembly Note: LV Motor Price includes a new capacitor Blower (For Lo-Velocity Units) Motors Blowers LV LV LV-120/ Weight Shipping Dimensions RA /5/ RA /5/ RA /5/ Note: The RA-100 fits the LV-120 and LV-140 Replacement Filters JH 15/30 (10.5 X 11 ) FR/RA-50 (14 X 18 ) FR/RA-70 (18 X 18 ) FR/RA-100 (18 X 24 ) Note: The FR/RA-100 fits the LV-120 and LV-140 Filter Racks (with filter) Weight Shipping Dimensions FR /4/ FR /4/ FR /4/ Note: The FR-100 fits the LV-120 and LV-140 Return Air Base (with Built-in Filter Rack, Filter) Hanging Strap Kit Hanging Strap Kit JH Fresh Air Damper Section Weight Shipping Dimensions JH F/A Damper Section 16 18/17/ Pg. 14
16 LV and JH Product Notes LV units come complete with painted, insulated cabinet, fan and 115/1/60 motor assembly, and pre-wired circuit board c/w heat/cool/aux. relays. Heating units are manufactured with six row water coils. RCM/RPM/WCM coil modules come complete with 2-7 /8 FIP drain pan connections (primary/secondary). RM/WM coil modules come complete with ½ PVC drain pan connections. RCM/RPM/RM Modules units come complete with drain pan, freeze stat, site glass, two Schrader valves, and expansion valve in either R22 or R410a refrigerant. Expansion valves are heat pump ready with a built in check valve. RPM-E Modules are pre-assembled with components as described above in either R22 or R410a refrigerant. JH Series fan coils come complete with water coil, painted insulated cabinet, 110/1/60 motor assembly, filter rack and filter. JH NP series (Northern Pak) come complete with JH fancoil, one 5 amp rheostat, ½ constant air temperature control, hanging strap kit and low temperature cut-out. JH NPF series (Northern Pak Full) come complete with JH fancoil, Northern Pak as above, an insulated intake air box c/w 8 collar and normally closed 110V damper motor. JH series Exhaust Air units come complete with painted insulated cabinet, 110/1/60 motor assembly, one 6 transition collar and one 8 transition collar. Filter Racks and Return Air Bases come with filter. Return Air Bases are acoustically lined and require field assembly. All measurements are in Imperial (Inch-Pound). To ensure ongoing product improvements, Energy Saving Products reserves the right to change any product without notice. Pg. 15
17 Builders Series Units HE Heating Fan Coils Supplied Standard with 6 Row Coil Output CFM Shipping Weight Shipping Dimensions HE-51H , /19/17 HE-52H , /19/17 HE-71H , /19/23 HE-101H , /19/29 HE Blower Units Shipping Weight Shipping Dimensions HE-51BU /19/17 HE-52BU /19/17 HE-71BU /19/23 HE-101BU /19/29 R4.2 Insulation 2 Flexible Duct (Sold in carton quantity only) Weight Shipping Dimensions 2 X 5 AFD (4/carton) 8 27/12/ X 10 AFD (4/carton) 12 15/15/ X 15 AFD (4/carton) 18 15/15/ X 25 UFD (1/carton) 8 10/10/ R8.4 Insulation Weight Shipping Dimensions 2 X 5 AFD (2/carton) 5 10/10/ X 10 AFD (2/carton) 10 15/15/ X 15 AFD (2/carton) 15 15/15/ X 25 UFD (1/carton) 12 15/15/ R4.2 Insulation HE Flexible Duct (Sold in carton quantity only) Weight Shipping Dimensions HE X 10 AFD (2/carton) 7 27/12/ HE X 15 AFD (2/carton) 11 26/15/ HE X 25 UFD (1/carton) /12/ R8.4 Insulation Weight Shipping Dimensions HE X 10 AFD (1/carton) 6 27/10/ HE X 15 AFD (1/carton) 10 25/15/ HE X 25 UFD (1/carton) 15 35/15/ Pg. 16
18 Builders Series Product Notes For Multi Unit applications ONLY, factory approval required for order acceptance. All HE Builders Series units come complete with galvanized cabinet, insulated casing, fan and 115/230/1/50/60 motor assembly, pre-wired circuit board and heat/cool/dehumidification/constant Fan/aux. relays, and are packaged with two vent plate keys. The heating output capacities are based on 190 F entering water temperature. AFD Assembled Flex Duct includes 5, 10 or 15 of Flexible Duct as specified plus one foot, two BC (Branch Couplers) attached, one BTO (Branch Take Off with Gasket) assembly, one Rough-In Kit, one Rough-In Cap and one Plastic Vent Plate. For Chilled Water applications consult factory For replacement parts and accessories, please refer to the standard price sheet. To ensure ongoing product improvements, Energy Saving Products reserves the right to change any product without notice. Pg. 17
19
20 Energy Saving Products Ltd., established in 1983, manufactures the Hi-Velocity Systems TM product line for residential, commercial and multi-family markets. Our facilities house Administration, Sales, Design, Manufacturing, as well as Research & Development complete with an in-house test lab. Energy Saving Products prides itself on Customer Service and provides design services and contractor support. Comfort from floor to ceiling, Satisfaction from room to room, with It s not just a dream, it s reality. TM HARDI Phone: (780) Fax: (780) Toll Free: velocity.com
Parts List * October 2013
Parts List * October 2013 Featuring: Small Duct High Velocity Heating, Cooling and Indoor Air Quality Systems TM HE-Z Series High Velocity Fan Coil LV-Z Series Conventional Replacement JH Series Space
More informationFeaturing: Small Duct High Velocity Heating, Cooling and Indoor Air Quality Systems
www.hi-velocity.com 2010 Parts List Featuring: Small Duct High Velocity Heating, Cooling and Indoor Air Quality Systems TM Also Including: LV-E Systems JH Fancoils Hi-Velocity Air Purification System PWM
More informationHI-VELOCITY SYSTEMS
INDEX ADD-ONS AND ACCESSORIES FILTER RACKS (WITH FILTER)... 2-5 HANGING STRAP KIT... 2-5 HI-VELOCITY AIR PURIFICATION SYSTEM ( PS)... 2-5 RETURN AIR BASE (WITH BUILT-IN FILTER RACK AND FILTER)... 2-5 COILS
More informationLV Installation Manual
LV Installation Manual Includes: LV-50 LV-70 LV-120 LV-140 Manufactured By Energy Saving Products Ltd. Module-LV-Series-Installation-Manual-111915 INSTALLATION, OPERATING, AND MAINTENANCE MANUAL LO-V UNIT
More informationJH Series Installation
JH Series Installation Space Heating / Fresh Air Make-Up From the Manufacturers of Hi-Velocity Systems TM Includes: JH-15 JH-30 Module-JH-Series-Installation-Manual-010118 Installation JH fan coils by
More informationLV Installation Manual
LV Installation Manual Includes: LV-50 LV-70 LV-120 LV-140 Manufactured By Energy Saving Products Ltd. ESP 202.02b INSTALLATION, OPERATING, AND MAINTENANCE MANUAL LO-V UNIT INSTALLATION INSTRUCTIONS Lo-V
More informationCommercial Applications
Small Duct High Velocity Heating, Cooling and Indoor Air Quality Systems TM Commercial Applications Manufactured by Module-COM-Commercial-Applications-Brochure-042116 The Hi-Velocity System is a Complete
More informationSECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS
1.0 GENERAL SECTION 15740 SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS 1.01 DESCRIPTION Item A. Scope This section specifies four sizes of fan coil units designed for hydronic heating and air conditioning.
More informationR Series Cooling Manual
Mini Duct Heating and Air Conditioning Indoor Air Quality Systems R Series Cooling Manual Includes: RPM-E-50 Cooling Module RPM-E-0 Cooling Module RPM-E-00 Cooling Module Manufactured By Energy Saving
More informationAirPurification System
The AirPurification System Installation and Operation Manual ONE SIZE FITS ALL! ESP 109.01 TABLE OF CONTENTS PARTS LIST........................................ 1 IMPORTANT SAFETY INSTRUCTIONS...................
More informationR Series Cooling Modules
TM Small Duct High Velocity Heating, Cooling and Indoor Air Quality Systems R Series Cooling Modules Models RCM-50 RCM-70 RM-100 Manufactured By Module-RCM/RM-Series-Installation-Manual-120113 Refrigerant
More informationSmall Duct High Velocity Heating, Cooling and Home Comfort Systems. HE-Z Series
Small Duct High Velocity Heating, Cooling and Home Comfort Systems HE-Z Series Installation Manual Includes: Hi-Velocity Fan Coils Heating Coils/Modules Cooling Coils/Modules Wiring and WEG Settings Add-ons
More informationR Series Cooling Modules
R Series Cooling Modules Models RCM/RPM 50 RCM 70 RM 100 RM 140 Manufactured By Energy Saving Products Ltd. Standard ESP 105.03 Refrigerant Modules (RCM/RM) Fig. 02 - Mounting brackets The cooling coil
More informationToll Free:
Small Duct High Velocity Heating, Cooling and Indoor Air Quality Systems Experience Superior Indoor Air Quality In Every Room The Hi-Velocity Systems Advantage tm As concerns over climate change and other
More informationRCM Refrigerant Module
Small Duct High Velocity Heating, Cooling and Home Comfort Systems RCM Refrigerant Module Installation Manual Manufactured By Module-RCM-Refrigerant-Module-Installation-0666 Refrigerant Modules (RCM) Fig.
More informationDCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners
DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER
More informationDCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER
DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER
More informationHV to HE Conversion Kit Installation
Small Duct Heating, ooling and Indoor Air Quality Systems www.hi-velocity.com TM HV to HE onversion Kit Installation Manufactured By Module HK - HV to HE onversion Kit Installation 032410 Motor and Blower
More informationHE-B Series Commissioning Report & User Guide
Small Duct High Velocity Heating, Cooling and Home Comfort Systems HE-B Series Commissioning Report & User Guide Manufactured By www.hi-velocity.com Module-HEB-COM-Commissioning-Report-and-User-Guide-061616
More informationVertiCool Aurora Engineering Guide
Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8
More informationDCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners
DCG Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant
More informationH3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog
H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...
More informationDCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h
Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: DCC Commercial 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling
More informationmaintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.
AHF / AHK SERIES AIR HANDLING UNITS INSTALLATION GUIDE GENERAL The AHF / AHK series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the
More informationDXair Pool Dehumidifiers
DXair Pool Dehumidifiers LV Series / to 6 Ton G-60 Galvanized The option-rich DXair LV Series pool dehumidifier has one of the smallest cabinets in the industry, making it a great choice for replacement
More informationESP. Variable Speed Heat Pump. Installation and Operation. 3 Ton ESP Ton ESP-60
Heating, ooling and Indoor Air Quality Systems ESP Variable Speed Heat Pump 3 Ton ESP-36 5 Ton ESP-60 Installation and Operation www.hi-velocity.com Module-VAR-Variable-Speed-Heat-Pump-060118 Installation
More informationDCG Commercial. Submittal Data Form
DCG Commercial Submittal Data Form 15-25 Tons Packaged Gas / Electric Units 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h 15 Tons
More informationREFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS
*s are Subject to Change without Notice.* REFLECTOR PANS FOR HINGED ELEMENTS Heavy Chromed Steel Description 2-1040 6" UNIVERSAL $2.19 2-1041 8" UNIVERSAL $2.89 2-1050 6" GE/HOTPOINT $2.39 2-1051 8" GE/HOTPOINT
More informationDSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER
DSC Series Submittal Data Form 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Standard
More informationDCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER
DCC Series Submittal Data Form Job Name 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By:
More informationPARTS LISTS GAS/T... 1 GAW... 3 GBS/T... 5 GES/T... 6 GFS/T... 8 GFW... 9
PARTS LISTS GAS/T... 1 GAW... 3 GBS/T... 5 GES/T... 6 GFS/T... 8 GFW... 9 Revised 12/01/17. APK Manufacturing reserves the right to make changes at any time without notice and without incurring any obligation.
More informationMHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH
MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed
More informationC13-Series Engineering Guide
Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................
More informationCabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan
Submittal Data Form Job Name DCC Series 3-6 Ton Packaged Air Conditioner 13 SEER / Up to 11.3 EER 6-Ton with Two-Speed Blower Motor and Two-Stage Compressor Up to 15.5 IEER Cooling Capacity: 34,600 71,000
More informationCabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan
DTC Series 3-5 Tons Packaged Air Conditioner Up to 15.5 SEER / Up to 13.0 EER Cooling Capacity: 35,600 60,000 BTU/h Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation
More informationFan Coils & Air Handlers Product Catalog
Fan Coils & Air Handlers Product Catalog 120V/240V motors PSC and ECM high efficiency constant torque motors Heavy-gauge, galvanized steel construction High efficiency rifled copper tubes/enhanced aluminum
More informationINSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER
INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER MODEL (INCLUDING HEATER MODEL #) SERIAL # INSTALLER INSTALLATION DATE These instructions should
More informationENGINEERING SPECIFICATIONS
ENGINEERING SPECIFICATIONS RH-24-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 24 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.
More informationENGINEERING SPECIFICATIONS
ENGINEERING SPECIFICATIONS RH-12-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 12 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.
More informationCB18/CBS18 Bulletin # September 1994 Supersedes August 1986
ENGINEERING DATA CB18 SERIES UP-FLOW CBS18 SERIES HORIZONTAL 2 To 5 Ton (7 To 18 kw) Nominal Cooling Capacity 7200 To 102 400 Btuh (2.1 To 30.0 kw) Optional Electrical Heat ENGINEERING DATA COILS MATCHED
More informationProduct Specifications. Vertical Floor Consoles By First Co.
NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series
More informationINSTALLATION INSTRUCTION
INSTALLATION INSTRUCTION MODULAR AIR HANDLER MODEL: N*AH CONTENTS GENERAL... 1 INSPECTION... 2 REFERENCE... 2 LIMITATIONS... 2 LOCATION... 2 BLOWER/COIL ASSEMBLY UPFLOW AND HORIZONTAL INSTALLATIONS...
More informationCoolSpot Engineering Guide
Engineering Guide Effective December 2017 Air-Cooled, Water-Cooled, Chilled Water or Magna Cool Precision Cooling Package Contents Contents....................................................... 2 Product
More informationCatalog C: McQuay Horizontal Concealed Fan Coil Unit
Catalog C: 700-1 McQuay Horizontal Concealed Fan Coil Unit Model THC Sizes 200 Through 1200 CFM McQuay THC Horizontal Concealed Fan Coil Nomenclature F THC 1 H02 Fan-coil Type of Unit THC = Horizontal
More informationFF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D
FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are
More informationMulti-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers
Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers 60 HZ Convertible Air Handlers Model: Series 2 Air Handlers 1.5-3 ton Standard Coil Black Epoxy Coil GAF2A0A18S11SE GAF2A0A18S11EE
More informationData Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified
Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A ISO 9001 Certified Data Aire the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first
More informationFAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design
FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design Fan motor (PSC or ECM). UL Listed 1 insulation conforms to UL Test 181 and NFPA 90A. Plenum air filter rack. (Filter Optional) Casing has
More informationK*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*
TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling
More informationVertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump
VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...
More informationMERIT Series R-410A - Upflow / Horizontal
PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw
More informationWE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL
PREPARED FOR: DATE: JOB NAME: WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL EQUIPMENT DETAILS ITEM TAG DESCRIPTION MODEL NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 EQUIPMENT
More informationMcQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017
Replacement s List 055208000 Revision E 08/207 McQuay Incremental MQS 007-05 Vintages A 02-05 Vintage B Last Manufactured: 993 To find your Daikin Applied parts distributor, call -800-377-2787 or visit
More informationP8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units
TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Single Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that
More informationMERIT Series R-410A - Upflow / Horizontal
PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0
More informationProduct Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS
Product Data FF1DNA, FF1DNE Fan Coil Units Sizes 018 thru 030 FF1D FEATURES/BENEFITS The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air
More informationSTELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: N2Y (795) N2Y (1195)
STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: 535.02-N2Y (795) 535.02-N2Y (1195) HEAT PUMP MODELS F1RP / F1FP018 thru 060 and COOLING MODELS F1RC / F1FC018 thru 036 035-13620
More informationSKYPAK II Heating & Cooling Self Contained Packages
SKYPAK II Heating & Cooling Self Contained Packages SKYPAK II gives you a complete airconditioning and heating system as an all-in-one package unit. Designed for conventional through-the-wall installation
More informationCLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS
7 Rosemex Products 97 VENTILATION CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS 2 INTRODUCTION Rosemex "Penthouse" units are essentially outdoor mechanical rooms. They group in one compact weather proof outdoor
More informationEXHAUST FAN SCHEDULE
DUCTWORK SCHEDULE CONCEALED SUPPLY AIR RECTANGULAR, RTU CONCEALED SUPPLY AIR RECTANGULAR, ERV CONCEALED SUPPLY AIR ROUND, RTU CONCEALED SUPPLY AIR ROUND, ERV EXPOSED SUPPLY AIR ROUND RUNOUTS RETURN AIR
More informationVERTICAL FAN COIL UNITS
VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote
More informationWhat is a High Velocity System?
What is a High Velocity System? What s different? Original concept introduced in 1946 for heat in aircraft High Velocity Systems utilize two or three inch outlets and distribution tubes to deliver the
More information48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS
48GS(N)018-060 STANDARD EFFICIENCY 48GX(N)024-060 HIGH-EFFICIENCY 48GS(N)-2SB SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION
More informationWALL-MOUNT HEAT PUMPS - (60HZ)
WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to 5,000 Cooling Capacities:,00 to 5,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling
More informationR7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units
TECHNICAL SPECIFICATIONS R7DA Series 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units 5.4 ISMRE Commercial System 81% Steady State Efficiency Standard Features Fits Pre-Existing Curbs High-Efficiency Low
More informationVert-I-Pak Series. Single Package Vertical Air Conditioners. Installs easily in a closet for quiet operation THE EXPERTS IN ROOM AIR CONDITIONING
Single Package Vertical Air Conditioners Vert-I-Pak Series Installs easily in a closet for quiet operation FRIEDRICH.COM THE EXPERTS IN ROOM AIR CONDITIONING Vert-I-Pak A Better Solution for Hospitality
More information48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS
48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,
More informationGreensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com
Greensource Residential Water Source Heat Pumps i Series: SV Model Simply Smart The i Series SV Model is a cost-effective single stage water source heat pump that is designed for commercial retrofit and
More informationCOMMERCIAL AIR HANDLER
COMMERCIAL AIR HANDLER FORM NO. H11-529 REV. 6 Supersedes Form No. H11-529 Rev. 5 Featuring Industry Standard R-410A Refrigerant RHGL- 090, 120, 180 & 240 SERIES NOMINAL SIZES 7.5, 10, & 20 TONS [26, 35,
More informationBCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY
PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED FORM NO. -100 (11/2015) APPLICATION 2-5 ton sizes Upflow, horizontal, and downflow capable Sequenced for demand management External access
More informationMERIT SERIES Up Flow / Horizontal
A I R H A N D L E R S CB26UH / CBX26UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D A T A Bulletin No. 210429 December 2006 Supersedes November 2006 Nominal Capacity 1.5 to 5 Tons Optional
More informationBOSCH RESIDENTIAL GEOTHERMAL HEAT PUMPS
www.bosch-climate.com INDEX AIR HANDLING UNITS UNITARY DX SERIES... 5-6 HYDRONIC SERIES... 5-6 HEAT PUMPS GEO 1000 WA BP SERIES... 5-4 GEO 3000 WA CE SERIES... 5-5 CP SERIES... 5-4 GEO 6000 WA / WW TA
More informationTECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36
TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36 Due to continuous product improvement, specifications are
More informationINSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER
INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER IMPORTANT MASSAGE TO INSTALLER: "The United States Environmental Protection Agency ("EPA") has issued various regulations regarding the
More informationCOMMERCIAL AIR HANDLER
COMMERCIAL AIR HANDLER FORM NO. H11-532 Featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant RHGM- 090 & 120 SERIES NOMINAL SIZES 7.5 & 10, TONS [26 & 35 kw] TABLE OF CONTENTS Unit Features...3
More informationAllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax
AllStyle Coil Company, LP 7037 Brittmore Houston, TX 77041 Phone 713-466-6333 Fax 713-466-6363 April 2005 VL / VLX Series Air Handler VL / VLX Series Air Handlers Installation Operation Maintenance The
More informationTHE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features
THE WALL-MOUNT ONE TON AIR CONDITIONER W2A,800 Btuh 9.00 EER Right Side Control Panel 60Hz GREEN REFRIGERANT R-A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating
More information1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series
1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor
More informationCeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A
A e r o S y s I n c o r p o r a t e d Ceiling Mounted Systems CeilMate TM Series 3 and 4 tons of cooling capacity Air Handler with Remote Condensing Unit Air Handler designed for R-410A AeroSys, Inc. 929
More informationHigh Heat COP. High/Low Stage
SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin
More informationINSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121
INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS Model: WA121 Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual : 2100-234 G Supersedes: 2100-234
More informationTechnical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer
Technical Development Program PRESENTED BY: COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems Ray Chow Sales Engineer TDP Updates Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section
More informationModular Supply Make-Up Air Unit
Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features
More informationModular Multi-position Air Handler
Modular Multi-position Air Handler Air Handler - Convertible Model: Series 2 Air Handler 3 ton with high efficiency motor GAF2A0A36M31SA PUB. NO. 22-1862-01 Features and Benefits Unique Cabinet Design
More informationCATALOG. SKYPAK Self-Contained Heating/Cooling Units
CATALOG SKYPAK Self-Contained Heating/Cooling Units FORM SK145.00-EG6 (1211) TABLE OF CONTENTS SKYPAK Self-Contained Heating/Cooling Units Introduction...3 Product Overview...3 Nomenclature...4 SKYPAK
More informationCAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS
DEHUMIDIFIERS 506451-01 04/2012 HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) FRONT VIEW (with alternate outlet location
More informationTHE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features
THE WALL-MOUNT ONE TON AIR CONDITIONER W2AAA 2,000 Btuh.00 EER Right Side Control Panel 60Hz Green Refrigerant R-4A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating
More informationCASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2
INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT
More informationRheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER
Air Handlers Rheem Air Handler RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Front or Bottom Return with aluminum tube and fin coil Flow Check
More informationRANGE. 2600/1950 Watts. 240/208 Volts BAKE ELEMENT /2100 Watts. 240/208 Volts. 90 degree BAKE ELEMENT Watts.
BAKE ELEMENT RANGE BAKE ELEMENT ADMIRAL AMANA CALORIC GLENWOOD HARDWICK IMPERIAL MAGIC CHEF MAYTAG WHIRLPOOL ROPER SUNRAY WELBILT 308180 2600/1950 Watts 240/208 Volts.250 male terminal push-in connection
More informationCabinet Unit Heaters Steam / Hot Water
11-160.4 February, 2005 Cabinet Unit Heaters Steam / Hot Water Model C MODEL IDENTIFICATION Table of Contents I. Model Identification... 3 Page Il. IIl. III. IV. Design Benefits A. Features and Benefits...
More informationInstallation Instructions
Installation Instructions PAM3 SERIES PACKAGE AIR CONDITIONERS TABLE OF CONTENTS SAFETY LABELING AND SIGNAL WORDS... 2 UNIT DIMENSIONS... 3 SAFE INSTALLATION REQUIREMENTS... 3 LOCATING THE UNIT... 3 CLEARANCES...
More informationAlpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018
Alpha Aire Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery Engineering Guide Effective February 018 CONTENTS PRODUCT FEATURES.......................... OPTIONS.....................................
More informationKIC Air Curtains. Technical Guide
TGKIC-3 KIC Air Curtains Technical Guide AIR PERFORMANCE AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. King certifies that the air curtains shown herein are licensed to bear the AMCA seal. The
More informationAIR HANDLERS AIR HANDLERS
FORM NO. H11-33 REV. 1 Supersedes Form No. H11-33 AIR HANDLERS AIR HANDLERS RHBL- Efficiency X-13 (ECM) featuring Industry Standard R-410A Refrigerant RHAL- Standard Efficiency PSC featuring Industry Standard
More information15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON
7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products
More information157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL
ENVIRONMENTALLY SOUND REFRIGERANT FEM4P, FSM4P Product Specifications FAN COILS ALL MODELS 1 1/2 thru 4 tons Available for environmentally sound R 410A systems Factory installed piston metering device
More informationSafety and Installation Instructions Model 1700
Dehumidifier Filter Access Humidity Control Inlet Filter Access Outlet Service Access Port Wiring Access Wire Routing Port Drain On/Off Switch Safety and Installation Instructions Model 1700 INSTALLER
More informationMODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS
With S&P s TR & TRC (total recovery) Series for all climates, stale room air is exhausted and fresh outdoor air is brought back into the house. These two air streams are directed through a highly developed
More informationRheem Air Handler. RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series PSC Motor Efficiencies up to 14.5 SEER
Air Handlers Rheem Air Handler RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RHAL- Series PSC Motor Efficiencies up to 14. SEER Front or Bottom Return Flow Check Piston for cooling or heat pump
More information