1 Installation Guide

2 2 TABLE OF CONTENTS 1.0 Multi-Flex Five Layer Composite Pipe Application Guide Product Applications Certifications and Test Approvals International Approvals Technical Data For Multi-Flex Pipe Description of Technical Data Comparison of Pipe Flow Charts (Coefficient of Roughness) Comparison of Expansion Differences Burst Pressure Chart Connections & Fittings Press Fitting Series Compression Fitting Series Tools General Installation Practices Handling and Storage of Product Connecting Multi-Flex Pipe to the fitting Layout of Pipework for Installations Provision for Expansion & Fitment Between Structures Insulation Protection from Ultra Violet Rays Installation Requirements According to ICC Listing Multi-Flex Water & Air Pipe Sizes Water & Air Pipe Dimensions and Packaging Water & Air Pipe Crimping Tong and Reamer Sizes Home-Run Manifold Systems Hydraulic Calculation Table for Water HVAC: Air Conditioning and Refrigeration Systems Variable Refrigerant Flow (VRF) Air-Conditioning Systems Residential HVAC Systems Air Conditioning Line Sets

3 AC Line Set Installation Five-Step Installation Demonstration Refrigeration Charge Chart HVAC Line Set Through Concrete Floor/Wall Multi-Flex HVAC Pipe Sizes HVAC Pipe Dimensions and Packaging HVAC Pipe Crimping Tong and Reamer Sizes Multi-Flex Gas Pipe, Fittings And Accessories For Gas Reticulation User Warnings Limitations of Gas Manual Applicable Standards & Listings For Multi-Flex Gas Pipe Important Information - Installing Multi-Flex Gas Pipe Gas Applications Multi-Flex Gas Pipe (Yellow Pipe) Overview Transition Risers Features and Benefits of Risers Available Riser Styles Multi-Flex Corrugated Stainless Steel Tube (CSST) Stainless Steel Coated with Uv Resistant and Anti-Flaming PVC Gas Catering Hose Gas Connectors (Coated and Uncoated) Mechanical Joints & Cutters Flexible Gas Connector - Uncoated or Yellow Coated Corrugated Extendable Hose - Uncoated or Yellow Coated Stainless Steel Flexible Tube with Braided Wire Stainless Steel Regulator Hose Caravan Hose Gas Meter Connector Striker Plates Stripwood Conduit Stub Outs Gas Outlet Box Manifolds Valves Shut-Off Valves

4 CSST System Installation Instructions CSST Technical Data Precautions when Installing Multi-Flex CSST Installation Requirements Bending Radius CSST Characteristics Installation Steps for CSST Cutting the Tube Preparing the Tube for the Fitting Attach the Fitting to the CSST Final Inspection Testing and Acceptance of the Gas Installation The Hydraulic Test Method The U-Gauge Test Method Layout of Pipework for Gas Installations Pipe Sizes for Gas Applications Gas Pipe Dimensions and Packaging Gas Pipe Crimping Tong and Reamer Sizes Multi-Flex CSST Sizes System Configuration and Sizing System Design Procedures Design Limitations System Configurations Flow Rates and Pressure Loss Tables Multi-Flex Gas Pipe Flow Rates - 1 PSI Multi-Flex Gas Pipe Flow Rates PSI Multi-Flex Gas Pipe Flow Rates PSI Multi-Flex Gas Pipe Pressure Loss Table Scope The purpose of this installation guide is not to present information on codes of practices, standards, legislation, regulations and by-laws, but rather to provide details on the general principles for handling, storage, product technical specifications, installation methods and testing of Multi-Flex s multi layer composite pipe and fittings. The knowledge with regards to codes of practices, standards, legislation, regulations and by-laws as set out by Local Authorities is to be applied and practised by the respective qualified installers. The responsibility is on the installer to certify the allowable correctness of an installation i.e. plumbing-, gas-, air-conditioning, water articulation, etc. Multi-Flex do not take any responsibility for the correctness or workmanship of any installation. 4

5 Multi-Flex Five Layer Composite Pipe Multi-Flex Pipe (P-A-P) consist of five layers. The outside layer is hi-density polyethylene while the inside layer is made up of cross-linked polyethylene. These two layers are tightly bonded with a special melt adhesive in the mid-layer of aluminum, which is longitudinally joined using an ultrasonic overlap welding technique. All these layers are extruded in one step to ensure a strong and solid Aluminum construction. Cross Linked PE The end result is a hygienic and toxic-free product. Bacterial growth is eliminated by preventing water, gas and oxygen permeability. Adhesive Layer Cross Linked PE Application Guide WATER Industrial and residential hot and cold water systems HEAT Radiant heat: Hydronic underfloor heating HVAC ACR: Air conditioning and refrigeration SOLAR Solar panel heating systems: Hydronic underfloor heating Natural fuel gas Compressed air systems GAS AIR Product Applications Industrial and residential systems for hot and cold water Pipeline systems for conveying potable water Heating pipelines for under-floor, wall and roof heating Pipelines for HVAC Pipelines for solar heating systems Pipelines for gas and coal gas Pipelines for oxygen transportation in hospitals Pipelines for electric wire and computer cabling Pipelines for compressed air Pipelines for fluid transportation in beverage factories Pipelines for irrigation in agriculture 5

6 Certifications and Test Approvals (Partial list - others per request) Multi-Flex Potable Water ICC-ES PMG 1067 listing NSF tested to the standard ASTM F 1281 (2008, 2010, 2011) and satisfying NSF 14 and NSF 61 according to the ICC listing Multi-Flex HVAC ICC-ES PMG-1221 listing ASME B31.5 Microbac test report (Colorado, US) Multi-Flex Gold Gas ICC-ES PMG 1142 listing AGA - American Gas Association Multi-Flex Radiant Heating (Hydronics) ICC-ES PMG 1067 listing NSF tested to the standard ASTM F 1281 (2008, 2010, 2011) and satisfying NSF 14 and NSF 61 according to the ICC listing International Approvals WRAS - Water Regulation Advisory Scheme Certificate Certificate for Product Exemption from Quality Surveillance Inspection ISO9001 International Quality System Certificate ISO14001 International Environmental Management System Certificate GOST - Russian National Standard Certificate Ukraine National Certification Association SABS - Certificate of South African Bureau of Standards JASWIC - Joint Acceptance Scheme for Water Installation Components AENOR - Certificate of Spanish Technical Certification Committee of Plastics Certificate of Standards Association of Australia PZH - Hygiene Certification of the National Institute of Hygiene in Warsaw DVGW - Certificate of Germany Association of the Gas and Water Industry Technical 6

7 Technical Data for Multi-Flex Pipe Thermal conductivity Coefficient of thermal expansion Bend radius Working temperature Oxygen -permeability Coefficient of roughness Corrosion resistance Burning resistance Hygiene Burst pressure/working Life span/warranty Detectable Static shield UV rating 0.26 Btu (IT) foot/hr/sq.ft./ F inch/(m.k) 5 x D (D = outside diameter) -40 F to 125 F e-5 inch Excellent Grade B1 of GB8624 Excellent 900 psi / 540 psi 50yr / 35yr Walls & underground with metal detector Excellent PPI 5306 according to Arizona weathering standards Description Of Technical Data Thermal Conductivity 0.26 Btu (IT) foot/hr/sq.ft./ F is about 1/100 that of steel pipe and several times higher than that of insulating materials. Heat preservation and energy-saving properties greatly minimize heat loss during water flow. This advantage allows extreme temperatures - especially for surfaces use in extreme cold conditions. It therefore has superior resistance to high temperatures, high pressure, corrosion and fire. Coefficient of Thermal Expansion inch/(m.k) is only 1/8 that of all polyethylene pipe and almost the same as that of steel pipe. See table. This advantage gives the user the option of laying the pipe inside concrete without worrying about a burst pipe or cracked wall. The aluminum middle layer has a very low linear heat expansion coefficient. Bending Radius The uniquely bonded layers of the Multi-Flex Pipe allow it to be bent at five or more times its outside diameter. It is advisable to use a bending spring or pipe bending tool, particularly with larger diameter pipes - but the smaller diameter pipe can also be easily bent by hand, saving both time and money. Working Temperature (F) The pipe has a high temperature and high pressure resistance, and can work under continuous normal working pressure with water temperature of -40 F to 125 F. 7

8 8 Oxygen Permeability The overlap-welded aluminum layer secures a 100% oxygen barrier and therefore prevents growth of microorganisms and bacteria. This hygienic advantage is especially well accepted and appreciated in the plumbing, medical and food industries. Coefficient of Roughness Cross-linked polyethylene (PEX) can be compared with thousands of steel wires that form a cable, instead of a solid steel tube. This smooth inner surface of the pipe reduces flow resistance to fluids and has the ability to convey water 30% more efficiently than metal pipes. Corrosion Resistance Besides eliminating corrosion, especially beneficial in coastal areas, Multi-Flex s multi-layer pipe does not dissolve in any known solutions and is resistant against various kinds of acids, alkali and salt at normal temperatures. Corrosion-resistant properties prevent encrustation build-up in the pipes, enabling the free flow of water and eliminating rust that can cause stains in tubs and basins. Burning Resistance The P-A-P composite structure of the Multi-Flex Pipe has a much better burning resistance than other polyethylene pipes. With the test by the National Fire-Proof Construction Materials Quality Supervisory Test Center, the burning resistance reaches Grade B1 of GB8624, the same stipulations that are used for wire and cable conduit plastic material. Hygiene Multi-Flex multi-layer composite pipe is hygienic, non-toxic, rust-free and prevents growth of microorganisms, therefore protecting against contamination of water and health risks. Burst Pressure The instant burst pressure of Multi-Flex Pipe tested at 900 psi. This is significantly more than is required for residential water recirculation, HVAC, refrigeration and certain gases. Lifespan Under normal operating conditions the Multi-Flex Pipe has a lifespan of 50 years, giving the end user peace of mind - and the installer more credibility. Detectability Metal detectors can be used to detect the pipe underground, in walls and in floors, thanks to the pipe s aluminum content. Static Shield Due to excellent static shield properties, it is often used to cover electrical cabling and computer cabling. 8

9 Comparison of Pipe Flow Charts (Coefficient of Roughness) 90 Loss of head (m) Heavy-rusted tube Concrete tube Wooden or mud-making tube Rusted tube Copper tube, iron cast tube Multi-Flex Composite pipe Comparison of Expansion Differences for 150 Feet Pipe at 122F (50C) (mm) PEX Pure PEX as found in Marley, Macflow and Afripex products PVC 200 Poly propylene as found in Citandoʼs product Ginde Multi-Flex PEX-AL 60 Copper 41.2 Galvanized Steel 28.5 Stainless Steel Work Temperature / Burst Pressure 73 F (23 C) 1000psi 125 F (52 C) 900psi 150 F (65 C) 540psi 9

10 Connections & Fittings Multi-Flex Pipe Systems manufactures a wide range of fittings. Press fittings, compression fittings and clamp fitting are used for a vast range of applications. The press fittings and crimp fittings are the most popular products for water reticulation in residential, commercial and industrial applications. For industrial and commercial applications where large volumes of fluid are conveyed, the clamp fittings are used on the larger-size composite pipe. Multi-Flex Pipe Systems has a full range of press fittings manufactured from brass and nickel-plated brass that consist of a double-layer O-ring system with a stainless steel crimp sleeve. The joining system can be compared to that of a hydraulic system accommodating high pressure. Electrical Corrosion Scientific tests have proven that if aluminum and copper are in contact with each other for more than eight months, obvious aging and electrical corrosion can occur. Multi- Flex Pipe has a polyethylene pad to prevent this. Specifications The Multi-Flex Pipe System must be installed using the Multi- Flex Pipe. All connections must be made using the Multi-Flex press, clamp or compression fittings and must be in accordance with the corresponding Multi-Flex Installation Guidelines. Polyethylene Pad (to prevent electrolysis) Brass Fittings and Valves Multi-Flex Composite Pipe has a polyethylene pad on the bottom of every fitting, completely separating the aluminum and brass fittings or valves. This prevents corrosion and increases the reliability and length of use. 10

11 11 For normal composite pipe joints, Multi-Flex supplies two types of typical fittings: Press Fitting Series Our press fittings are made of high-quality materials, created through a cold-cut and hot-forged process. They have a new design and attractive appearance, and feature heat-treated technology. Unique joining tools are designed for reliable, faster connections, and press fittings create great sealing for a long working life. Press fittings are useful for a wide range of applications. They are used for hot and cold water supply, heating, inert gases, gas supply, oxygen and air supply, and other challenging environmental applications such as vibration-prone areas. Crimp Sleeve O-Rings Compression Fitting Series Our compression fittings are used in many applications. They work well at higher pressures, and with toxic gases. During manufacturing, a forging method is used to rid the surface of impurities. This increases the intensity and pressure to enterprise standards and makes the fitting particularly effective against leakage. The brass C-Ring in the fitting brings double protection of tightness and non-leakage. 11

12 Tools (Refer to the catalog for additional tool information.) Hand Pipe Cutter Hand Reamer Pipe Bending Spring REMS Hand Crimping Tool REMS Hand Pipe Bender REMS Electric Crimping Tool REMS Curvo Power Bender REMS Hydraulic Pipe Bender Multi-Flex Pipe Straightener 12

13 General Installation Practices All planning, installation and design work should be carried out in accordance with the national standards and U.S. codes for the specific installation as well as Multi-Flex technical & installation information. Refer to the Hydraulic Calculation Table in the Appendix at the end of the guide to determine the pressure loss when designing the pipe system Handling and Storage of Product 1. Pipes and fittings should be treated carefully during transportation, load and unload. Do not throw, fall, roll or drag any of the products. 2. Store away from any polluted areas, and do not store with oil or chemicals. 3. Do not store in direct sunlight. Keep away from heat sources. Pay attention to fire safety. 4. Pipes should be stored on a flat surface. Avoid pressure which may distort the pipe or cause mechanical damages. 5. Product should be stored and piled in the original packaging. The stacking height for piles should be: Pipes: less than 6 feet high Fittings: less than 3 feet high Marking on packages will be visible and will read Multi-Flex Pipe Systems Before any installation, acknowledge the mark on the pack as well as on the product. 13

14 Connecting Multi-Flex Pipe to the fitting Step A: Cut the pipe to the required length with the special pipe scissor or cutter. Step B: Ream the pipe by pushing the reamer into the pipe and turning. This cuts the pipe end straight while cutting chamfers on the inside and outside of the pipe end. The design of the reamer will prevent shavings from falling into the pipe. Step C: Inspect the stainless steel sleeve for any cracks, and then fit it over the pipe to be flush with the pipe end. Inspect the fitting to ensure: There are no cracks. That the white collar is: fitted, is intact and is without any lacerations. That the 2 O-rings: are fitted, are intact and are without any cracks or lacerations. O-Ring Collar O-Rings Sleeve Step D: Carefully push the fitting into the pipe until it clips into the white collar without dislocating the O-rings, and without moving the sleeve away from the pipe end. 14

15 15 Step E: Crimp the sleeve with a REMS crimping tool. 1. Locate the tool s jaws tight against the collar. 2. Compress the sleeve by closing the REMS crimping tool until the handles meet and make a clicking sound. Do this only once. Step F: Visually inspect the fitting, and test the crimp with the crimp tester tool if needed. Step G: Bend the pipe to the desired angle using the correct size-bending spring or REMS hydraulic bender Layout of Pipework for Installations The following requirements shall be considered and applied in addition to any similar specification details that might be introduced by the installer: 1. Connecting pipes shall be firmly anchored to prevent water hammer and the dislodgement of joints. 2. Unless otherwise approved, pipes laid underground shall have a soil cover over the outside of at least 450mm, but not more than 1m, for any pipe of nominal diameter less than 75mm. 3. Where any portion of a pipe is concealed in a floor, concrete slab or wall, the following shall apply: a. Striker plates should be used inside the wall (see fig for examples of striker plates) b. Adequate measure shall be taken to protect the portion of pipe from external pressure or from the transmission of any load to it. c. No pipe shall be installed within the cavity of any cavity wall, nor shall pipe pass through concrete expansion or concrete joints. 4. Multi-Flex pipe may not be used as the safety valve pipe on water heaters. 15

16 16 Fig Striker Plates TYPE QSP 1-1/2 WIDE X 3-1/2 LONG TYPE EFSP 2-3/4 WIDE X 13 LONG TYPE FSP 2-3/4 WIDE X 11-1/2 LONG TYPE HSP 2-3/4 WIDE X 6-1/2 LONG TYPE DTSP 2 3/4 -WIDE X 7-1/4 LONG TYPE LSP 3-1/4 WIDE X 17-1/2 LONG Provision for Expansion & Fitment Between Structures a. The pipeline will expand with an increase in temperature. This phenomenon is applicable to all pipe types and although it does not have an adverse effect on the performance of the pipe and joint, it must be taken into account when installing hot water systems. b. For both straight laying or non-straight laying pipelines with a pipe diameter of less than or equal to 1 inch, the pipeline expansion compensation is not required. c. To accommodate for the expansion of the pipe within the structure, you must provide insulated expansion bends at least every 30ft. When this has been insured, the pipe can be buried or built into the structure. See diagram below: Spacing between the fixing and supporting brackets Nominal Diameter DE (inches) Vertical Pipe (inches) Horizontal Pipe (inches) Expansion Bend d. It is preferred to always provide the pipes with a protective sleeve or insulation. The sleeve has a protective function, while the insulation not only protects and thermally insulates the pipe - it also prevents the formation of condensation. To determine the insulation thickness, the following rule can apply: 1.5 x L (change in length) e. Pipe brackets must be Fig

17 17 used when fixing pipelines to the surface. The brackets can be synthetic or metal with a synthetic inner lining for protection of the pipe. The specified maximum distances between brackets must be adhered to. See figure on the previous page. Pipe Brackets L L Support brackets or holder bats must be fitted on either side of all fittings The pipe brackets have a twofold purpose: (1) to support the pipe network, and (2) to accommodate the thermal length changes of the pipeline with sliding and fixed points, usually with correctly calculated expansion bends and expansion loops. The sliding points must be such that the pipe has continuous clearance. The sliding point may not become a fixed point when the pipe expands. The correct placing of sliding points and fixed points is very important when expansion bends and expansion loops are used. In all cases where the pipeline changes direction, expansion bends must be provided for. The minimum length for the expansion bend can be calculated on the basis of the following formula: where: * * L b = C * (D * where: C = material constant = 33 D = outside diameter of the pipe = square root L L LL F F L b L b F 17

18 18 When a long pipe does not change direction, expansion loops are required. An expansion loop is also called a lyra-, omega- or horseshoe bend. The drawings below clarify what an expansion loop is. The expansion loop is, in principle, formed by 2 expansion bends. A fixed point must be provided at the top or bottom in the middle of the loop. Flow Flow Flow Flow The installer must also ensure that pipes can move freely when piping runs from floors to a riser pipe in a shaft, or when piping runs between rooms or buildings through walls or structures. Also here, the installer must provide for change in length due to expansion. This change can be accommodated by expansion bends or loops. Sleeve L b L b Lb If the riser pipe is longer than 30 feet, a fixed point must be provided. It is recommended to have this point in the middle of the pipe because expansion forces generated are smaller. When pipes are fitted through holes in a wall or ceiling, the pipe must at least be protected with a sleeve. In addition, the pipes should never be fitted around a sharp edge, in order to prevent kinking or chafing. The installer should round off any sharp edges. Round edge Sharp edge 18

19 Insulation Thermal insulation may be required to reduce heat loss through the pipe. The fluid (water) flowing inside the pipe should be prevented from freezing at all times. Snap-on, preformed glass fibre insulation or other approved isolation material with a density of at least 3.75 lb/ft 3 (60 kg/m 3 ) should be used. The insulation thickness shall be as follows: Service Cold water Hot water Nominal Pipe Size (up to 2 inches) 0.6 inch 1 inch Equipment and piping must first be pressure tested before any insulation is installed. It is not always possible to completely prevent static water from freezing. In these cases, it would be necessary to circulate warm water periodically through the pipe system Protection from Ultra Violet Rays In the event that the piping system is exposed to direct sunlight, such an installation should be protected against ultra violet exposure. This protection can be done by covering the pipe. The pipe can also be painted with a UV-resistant paint for protection. It is important to apply an undercoat such as Plascon s Melamine Primer or Rust-Oleum s Pegalink-Universal Adhesion primer before the final UV-resistant coat is applied Installation Requirements According to ICC Listing During placement of cover over the tubing, the tube must be maintained at the greater of 1.5 times the working pressure or 100 psi (689.4 kpa). The tubing installation must be pressure-tested for leaks in the presence of the code official or the code official s designated representative. When installation is in fire-resistance-rated assemblies, evidence must be provided to the code official of compliance with International Building Code (IBC) Section 713 (penetrations), Uniform Building Code (UBC) Section 709 (walls and partitions) or UBC Section 710 (floor/ceiling or roof/ceiling), as applicable. The tubing must not be used as a source of electrical ground. Pipe bends must be installed in accordance with the manufacturer s published installation instructions. When the system is embedded in concrete, tubing must be covered a minimum of 0.75 inch (19.1 mm) and installation must comply with IBC Section or UBC Section , as applicable. The tubing is manufactured in Shenyang, Liaoning Province, China, under a quality control program with surveillance inspections by ICC-ES. 19

20 Multi-Flex Water & Air Pipe Sizes Potable Water Radiant Heating Solar Heating Compressed Air WATER HEAT SOLAR AIR Water & Air Pipe Dimensions and Packaging Specification Size classification Exact Dimensions Packing (ft/carton) Packing (m/carton) Carton Size (inches) Carton Size (mm) Weight (lb's) Weight (kg) Inner (inches) Outer (inches) 1216X 1/2" / x8x X 5/8" / x8x X 3/4" / x8x X 1" / x10x X 1 1/4" ft stick 36 5x5x X 1 1/2" ft stick 36 6x6x X 2" ft stick 16 5x5x Water & Air Pipe Crimping Tong and Reamer Sizes Pipe Description Pipe Size ID Crimping Tong Size Code Reamer Code 1/2" 0.47 inch U16 ZYD12 5/8" 0.63 inch U20 ZYD16 3/4" 0.79 inch U25 ZYD20 1" 1.02 inch U32 ZYD25 1 1/4" 1.26 inch U40 ZYD32 1 1/2" 1.61 inch U50 ZYD41 2" 2.00 inch U63 ZYD51 20

21 Home-Run Manifold Systems Protection against concealed leaks: Benefits in High Rise Multi-Family Construction WATER With this system, a main water line feeds the manifold, which is located within the mechanical closet or washer/dryer closet (commonly 3/4 or 1 ); smaller lines run from the manifold to each fixture (commonly 1/2 ). Any fixture in the apartment can be shut off at the manifold. The manifold system removes joint connections at every fitting and decreases the number of connections by approximately 100 to 120 connections per apartment, which in turn greatly reduces the probability and chance for leaks above concealed spaces. Leaks above concealed spaces are detrimental in high rise stacked construction, as damages likely occur on floors below, resulting in displaced tenants, interruptions in rent cycles, extensive insurance claims and poor perception of the quality of the building systems. Leaks above concealed spaces have also caused mold growth and micro-bacterial issues that go unnoticed until a catastrophic leak occurs. A home-run manifold system with Multi-Flex Pipe Systems can help owners mitigate the risk of leaks in concealed spaces and limit the probability of leaks by decreasing connections above concealed spaces - often by over 100 connections. No Fittings With Fittings X 3/8-in. tube Manifold 1/2-in. tube 3/8-in. tube 3/4-in. tube 21

22 Hydraulic Calculation Table for Water Hydraulic Calculation Table for Water - A A DA 14 DB 10 DA 16 DB 12 DA 18 DB 14 DA 20 DB 16 DA 25 DB 20 Vs Litre/second V m/s R Pa/m V m/s R Pa/m V m/s R Pa/m V m/s R Pa/m V m/s R Pa/m

23 23 Hydraulic Calculation Table for Water - B B DA 32 DB 26 DA 40 DB 32 DA 50 DB 41 DA 63 DB 51 DA 75 DB 60 Vs Litre/second V m/s R Pa/m V m/s R Pa/m V m/s R Pa/m V m/s R Pa/m V m/s R Pa/m

24 ACR: Air Conditioning and Refrigeration Systems HVAC Multi-Flex Pipe is perfect for use in refrigerant piping layouts for commercial and residential air conditioning and VRF systems. And its core strength and flexibility makes it an ideal piping material for refrigeration installations. Multi-Flex Pipe is tested and proven to withstand the temperatures and pressures of today s popular refrigerants, and is installed with standard trade practices as per AHRAE standard. Multi-Flex five layer composite pipe can be used in conjunction with other metal pipes, and the installation of shut off valves at the supply lines with P-A-P tubing enables easy repair. Thanks to its flexibility, Multi-Flex Pipe is supplied in coils. This means it can be installed in one continuous length, making installation considerably easier and eliminating the need for fittings. Multi-Flex line sets are supplied in various lengths and can be installed without any soldering or brazing. Incorrect Correct Liquid Line Tape Insulated Vapor Line Refrigeration Line Support Sheet Metal Hanger Multi-Flex Pipe Variable Refrigerant Flow (VRF) Air-Conditioning Systems Multi-Flex Pipe is often used in VRF systems to connect the indoor units (evaporators) to the controlling manifold. See the illustration below. A VRF system consists of a number of air handling units connected to a modular external condensing unit. The term variable refrigerant flow refers to the ability of the system to control the amount of refrigerant flowing to the multiple indoor units, enabling the use of many evaporators of differing capacities and configurations connected to a single condensing unit. The arrangement provides individualized comfort control, and simultaneous heating and cooling in different zones. Outdoor Unit Condenser Multi-Flex Pipe Liquid Pipe Controlling Manifold Possible Future Extension Gas Pipe Indoor Unit Indoor Unit Indoor Unit Indoor Unit Indoor Unit Multi-Flex Pipe Evaporators Indoor Unit Indoor Unit Indoor Unit 24

25 Residential HVAC Systems Multi-Flex AC line sets are designed to replace copper pipe in residential HVAC installations. The flexibility and ease of installation makes replacing coolant lines quicker than ever. It also eliminates the ever-increasing problem of copper theft. See the illustration below. HVAC Components of a typical residential heating and cooling system Evaporator Condenser Unit Fan Air Supply Plenum Air Return Blower Compressor Furnace Outdoor Unit Multi-Flex Line Set (Coolant Lines) Air Conditioning Line Sets Multi-Flex AC line sets are leak-proof and have a high degree of resistance to pressure and temperature variations, making them very suitable for areas with extreme weather conditions. The P-A-P composition is also extremely resistant to frost damage. 25

26 AC Line Set Installation Easy 5-Step Installation (HVAC Transition Connector Installation Demonstration) 1. Cut pipe to length 2. Ream inside of pipe 3. Slide sleeve onto pipe Insert fitting into pipe 5. Crimp sleeve Installation complete Work Temperature / 73 F (23 C) Burst Pressure 1000psi 125 F (52 C) 150 F (65 C) 900psi 540psi Refrigeration Charge Chart AC Pipe AC Pipe AC Pipe AC Pipe AC Pipe AC Pipe AC Pipe AC Pipe AC Pipe Pipe Size (Metric) Pipe Size (inches) Inner (inches) Outer (inches) Volume of 1 lin ft of pipe (cf) Density of liquid R410A (lb/cf) Lb charge/ft Lb charge/35ft Lb charge/50ft Lb charge/ 100ft 0912X 1/4" X 3/8" X 1/2" X 5/8" X X 3/4" X 7/8" X 1 1/8"

27 HVAC Line Set Through Concrete Floor/Wall or Block Wall Assembly F-Rating = 2-HR T-Rating=0-HR HVAC Top View Section A-A Top View Section A-A 1. Concrete floor or wall assembly (2-hr. fire rating) A. Lightweight or normal weight concrete floor or wall (minimum 4-1/2 thick) B. Precast (hollow-core) concrete Annular floor (minimum Space 6 thick) 2. Optional: maximum 4 nominal diameter steel pipe sleeve (schedule 10 or heavier) 3. Maximum 1 nominal diameter multi-flex pipe 4. Maximum 1/2 nominal diameter multi-flex pipe 5. Normal 3/4 thick ab/pvc pipe insulation 6. Maximum 4-pair no. 18 AWG thermostat cable with pvc jacket 7. Minimum 4 thickness mineral wool tightly packed and recessed to accommodate firestop sealant 8. Minimum 1/4 depth intumescent firestop sealant 9. Minimum 1/4 bread intumescent firestop sealant at point of contact Annular Space Minimum Maximum Notes: 1. Maximum diameter of opening = 4 2. When pre-cast floors are used, mineral wool should be installed flush with bottom surface of floor. 3. Intumescent firestop sealant must be applied into interstices of a bundle to the maximum extent possible. 4. Minimum 1/4 depth intumescent firestop sealant is required on each side of wall assembly. 27

28 Multi-Flex HVAC Pipe Sizes HVAC HVAC & Refrigeration HVAC Pipe Dimensions and Packaging Specification Size classification Exact Dimensions Packing (ft/carton) Packing (m/carton) Carton Size (inches) Carton Size (mm) Weight (lb's) Weight (kg) Inner (inches) Outer (inches) 0912X 1/4" / X 3/8" / x9x X 1/2" / x8x X 5/8" / x9x X 3/4" / x8x X 7/8" / x8x X 1 1/8" / x10x HVAC Pipe Crimping Tong and Reamer Sizes Pipe Description Pipe ID Pipe OD Crimping Tong Size Code Reamer Size Code 1/4" 0912X U12 ZYD09 3/8" 1014X U14 ZYD10 1/2" 1216X U16 ZYD12 5/8" 1418X U18 ZYD14 3/4" 1620X U20 ZYD16 7/8" 2025X ,024 U25 ZYD20 1 1/8" 2532X U32 ZYD25 28

29 Multi-Flex Gas Pipe, Fittings and Accessories for Gas Reticulation IMPORTANT - READ ENTIRE MANUAL This document is the sole property of Multi-Flex Pipe Systems. It shall not be copied or reproduced without the prior permission of Multi-Flex USA. WHILE EVERY EFFORT HAS BEEN MADE TO PREPARE THIS DOCUMENT IN ACCORDANCE WITH THE MOST CURRENT MODEL CODES IN EFFECT AT ITS PRINTING, MULTI-FLEX PIPE CANNOT GUARANTEE THAT THE LOCAL ADMINISTRATIVE AUTHORITY ADOPTS OR ACCEPTS THE MOST RECENT EDITION OF THESE CODES. THE INSTALLER IS ULTIMATELY RESPONSIBLE FOR DETERMINING SUITABILITY AND ACCEPTANCE OF ANY BUILDING COMPONENT, INCLUDING GAS PIPING. MULTI-FLEX PIPE ASSUMES NO RESPONSIBILITY FOR MATERIALS OR LABOR FOR INSTALLATIONS MADE WITHOUT PRIOR DETERMINATION OF LOCAL CODE AUTHORITY ACCEPTANCE User Warnings (see section 1.8 of ANSI LC 1-CSA ) The use of fuel gas can be dangerous. Special attention must be given to the proper design, installation, testing and application of the gas piping system. Sound engineering practices and principles must be exercised, as well as diligent adherence to the proper installation procedures to insure the safe operation of the piping system. Prior to being placed into service, all installed systems must pass customary installation inspections by the local building official having authority. This document is intended to provide the user with general guidance when designing and installing a MULTI-FLEX PIPE corrugated stainless steel tubing gas system manufactured by Multi-Flex USA. Its use with any other gas tubing system is inappropriate and may result in serious bodily injury and property damage. Where local gas or building codes impose greater requirements than this document, you should adhere to the local code requirements. Performance of accessory devices, such as pressure regulators and shut off valves, should be reconfirmed by contacting the accessory device manufacturer and receiving the latest technical data on sizing, installation and performance. Improper installation methods or procedures could lead to accidents such as explosions, fires, gas poisoning, asphyxiation, etc. This system shall be installed with strict adherence to this guide as well as local building codes. All installed systems must pass installation inspections by the authorized local building official prior to being placed in service. Multi-Flex Pipe Systems shall have no responsibility for any misinterpretation of the information contained in this guide or any improper installation or repair work or other deviation from procedures recommended in this manual, whether pursuant to local building codes or engineering specifications or otherwise. Only those components designed and made for or specified for use in this system shall be used in its installation. MULTI-FLEX PIPE components and tubing shall not be used with other corrugated stainless steel tubing system components from other manufacturers. MULTI-FLEX PIPE shall be used only in gas piping systems where the operating gas pressure does not exceed 25 PSI. Accessories for systems shall be rated for the operating gas pressure used. Thus, for example, accessories for 25 PSI systems shall be rated for 25 PSI service. Performance of accessory devices, such as pressure regulators and shut-off valves, should be reconfirmed by contacting the accessory device manufacturer and receiving the latest technical data on sizing, installation and performance. Certain chemicals are corrosive to MULTI-FLEX PIPE. Contact your distributor for more specific information on this topic. 29

30 30 A gas delivery system consisting of MULTI-FLEX PIPE offers significant advantages over other gas delivery systems because of its wall dimensions and corrugated design. In contrast to rigid steel pipe, MULTI-FLEX PIPE does not require intermediate joints in most installations because the tubing is capable of being installed in one continuous run, reducing not only the total number of joints, but also the potential for leaks at joints. MULTI-FLEX PIPE s flexibility also affords more installation options because an installer can avoid existing obstacles, and it eliminates the repetitive measuring, cutting, threading and joint assembly that are common with the installation of rigid steel piping systems. Although MULTI-FLEX PIPE provides significant advantages over more rigid gas delivery systems, its wall dimensions may make it more likely than steel pipe to be punctured by a nail or other sharp object, or damaged by other extraordinary forces such as a lightning strike, depending on the circumstances. It is well known that lightning is a highly destructive force. Therefore, the user must ensure that the system is properly bonded and grounded. In order to maximize protection of the entire structure from lightning damage, the user should consider installation of a lightning protection system per NFPA 780 and other standards, particularly in areas prone to lightning. Note that lightning protection systems as set forth in NFPA 780 and/or other standards go beyond the scope of this manual. Users of MULTI-FLEX PIPE should consider all of the limitations and benefits of MULTI-FLEX PIPE for their particular situation. Installers shall provide building owners and electricians with the required information documentation discussing these limitations and benefits Limitations of Manual This document is intended to aid the user in the design, installation and testing of MULTI-FLEX PIPE Corrugated Stainless Steel Tubing to distribute fuel gas in residential housing units and commercial structures. It would be impossible for this guide to anticipate and cover every possible variation in housing configurations and construction styles, appliance loads and local restrictions. Therefore, there may be applications which are not covered in this guide. For applications beyond the scope of this guide, contact Multi-Flex Pipe Systems Engineering Department. The techniques included within this guide are recommended practice for generic applications. These practices must be reviewed for compliance with all applicable local fuel gas and building codes. Accordingly, where local gas or building codes impose greater requirements than this manual, you should adhere to the local code requirements. This system and related components should be used only as fuel gas piping where the operating gas pressure does not exceed 25 PSI Applicable Standards & Listings Multi-Flex Gold Gas ICC-ES PMG 1142 Listing AGA - American Gas Association 30

31 Warnings 1. The installation of MULTI-FLEX PIPE must be performed by a trained, qualified installer. The installer must also meet all qualifications required by the state and/ local administrative authority administering the provisions of the code where the piping is installed. 2. All piping systems using MULTI-FLEX PIPE shall be designed and installed according to the requirements of this guide. 3. Only Multi-Flex components may be used in the system. Components from other systems are not interchangeable. 4. Installation shall be in accordance with local codes, or in their absence, in accordance with the National Fuel Gas Code ANSI Z223.1 in the USA, and CAN/CGA - B149.1 & B149.2 in Canada. In cases where the requirements of this guide are in conflict with the local code, the local code must take precedence, unless the local authority having jurisdiction approves a variance, or change. 5. Inspection, testing, and purging shall be performed according to the procedures in Part 4 of the National Fuel Gas Code, ANSI Z223.1, and/or - B149 installation Codes or in accordance with local codes. 6. The gas piping system and related components shall be used only in systems where the operating gas pressure does not exceed 25 PSIG. 7. Tubing with covering may be installed in or routed through air plenums, ducts, or other areas which may be limited by building codes to materials having maximum ASTM E84 ratings of 25 Flame Spread and 50 Smoke Density. Other procedures are to be followed by the installer to meet local building codes with respect to Flame Spread and Smoke Density regulations for nonmetallic materials. 8. Tubing may be routed through concrete floors or walls, provided it is passed through previously embedded conduit. Tubing shall not be buried directly underground. 9. The CSST is typically routed: Beneath, through and alongside floor joists Inside interior wall cavities On top of ceiling joists in attic space 10. Carefully unwind and route the tubing from the reel to the required location, making certain not to kink, tangle or apply excessive force. 11. Tubing end must be temporarily capped or taped closed prior to installation to prevent contamination from foreign material. 12. When installing MULTI-FLEX PIPE avoid sharp bends, stretching, kinking, twisting, or contacting sharp objects. The tubing must be replaced if damage occurs. 31

32 Gas Applications Multi-Flex Gas Pipe Multi-Flex Gas Pipe (yellow) is used underground up to the gas meter. Transition Risers are used to connect the underground pipe to the aboveground Corrugated Stainless Steel Tube that is used throughout the system. A gas delivery system consisting of Multi-Flex Pipe offers significant advantages over other gas delivery systems. No sleeve is needed for underground piping and in contrast to rigid steel pipe, Multi-Flex Pipe does not require intermediate joints in most installations because the tubing is capable of being installed in one continuous run, reducing not only the total number of joints, but also the potential for leaks at joints. GAS Multi-Flex Pipe s flexibility also affords more installation options because an installer can avoid existing obstacles, and it eliminates the repetitive measuring, cutting, threading and joint assembly that are common with installation of rigid steel piping systems Transition Risers Transition Risers offer a safe and simple method of connecting and transitioning Multi-Flex Pipe to steel pipe. They offer the ability to transition Multi-Flex Pipe from a below-ground application to an above-ground piping system. Compression fittings allow the user to connect and/or transition P-A-P to steel without the need for fusion equipment. Proper installation of these fittings provide a mechanical joint that is stronger than the PE pipe itself. These fittings have been safely and effectively used in Natural Gas Plumbing, Pool and Spa applications and LP Gas. Transition Risers and Compression Fittings can be selected from a group of standard items or can be manufactured to meet the customer s specific requirements Features and Benefits PE-to-Steel transition joint is stronger than the PE pipe. The riser utilizes an O-Ring design for added protection (one-piece design). All products are protected with an electrostatically applied fusion-bonded epoxy powder coating specifically designed for the exterior of gas petroleum pipelines. 32

33 Available Riser Styles Systems. Pre-bent Pre-bent w/extended length of PE pipe Straight Straight w/fused pup Flexible Steel flex Anodeless Riser w/ Extended Length of Pipe Transition Fittings Flexible Riser Pre-Bent Riser Multi-Flex Corrugated Stainless Steel Tube GAS Multi-Flex Corrugated Stainless Steel Tubing (CSST) makes installing gas piping for natural gas or propane gas appliances quick and easy. The Multi-Flex fitting system and flexible tubing enable installers to reduce installation time and eliminate the equipment needed to install gas piping in new or existing construction. Multi-Flex CSST can supply gas throughout a home or commercial building. It can be routed through walls, floor or ceiling joists, or routed outside to a variety of appliances. Multi-Flex Corrugated Stainless Steel Tube is manufactured out of high quality stainless steel and the outer layer consists of a fire resisting polymer composite material. Stainless steel with a high corrosion-resistance content is used that ensures safety and a life span of 50 years plus. Available in sizes of ½, ¾ and 1 CSST 33

34 Stainless Steel Coated with UV Resistant and Anti-flaming PVC GAS Corrugated Stainless Steel Tubing comes with useful accessories and tools and can be safely connected to many pieces of gas equipment. Flexibility and durability allow for simple routing through complex building structures and designs. The tubing is pre-marked by each meter for easy measuring and installation and is flexible with a minimum bending radius of 120 degrees. Stainless Steel Coated with UV Resistent and Anti-flaming PVC PART NO. SIZE (INCH) ID(MM) OD(MM) THICKNESS LENGTH (M) RFB1230 1/ RFB1250 1/ Stainless Steel Coated 3/4 with UV RFB3430 Resistent and Anti-flaming RFB3450 3/4 PVC PART NO. RFB130 RFB1230 RFB150 RFB1250 SIZE (INCH) 1 1/2 1 1/2 ID(MM) OD(MM) THICKNESS LENGTH (M) RFB3430 3/ / Gas Catering Hose RFB3450 Gas Catering Hose Features: RFB130 1 OD 25 StainlessIDsteel hose and PART NO. SIZE ENDends THICKNESS 30.8 WORKING 0.25 LENGTH 30 MATERIAL RFB150 (inch) 25 mm Fully welded - r 100%M.I.P pressure tested (mm)1 (mm) 30.8 PRESSURE 0.25 (mm) 50 SUS316L Hose;SUS304, 1000, 1500, or End: stainless steel or customized carbon steel 1/2 Covered15in top-quality PVC - corrosion 22 R1/ resistant and anti-wrinkle ZJT34FM 3/ R3/4 Fully approved to BS669 Part 2: 1997 ZJ12FM 0.5 Mpa Gas Catering Hose PART NO. SIZE ID OD END THICKNESS WORKING LENGTH MATERIAL (inch) (mm) (mm) M.I.P mm PRESSURE (mm) Hose;SUS304, SUS316L ZJ12FM 1/ R1/ Mpa 1000, 1500, or End: stainless steel or ZJT34FM 3/ R3/4 customized carbon steel 34

35 Gas Connectors (Coated or Uncoated) Our stainless steel gas connectors are made of premium materials to ensure maximum levels of safety. Each stainless steel gas connector has end adaptor fittings which are threaded inside and out, and metal circularity technique is used. Our CSA-certified stainless steel gas connectors are widely used in the U.S. These connectors are designed to connect to nearly all types of gas equipment, including ovens, drying equipment and water heaters. Uncoated Stainless Steel Gas Connectors PART NO. FB38**A FB38**D FB38**E FB38**B FB38**F FB38**C SPECIFICATION 1/2 FIPX1/2 FIP 1/2 FIPX3/8 FIP 3/8 FIPX3/8 FIP 1/2 FIPX1/2 MIP 3/8 FIPX3/8 MIP 1/2 MIPX1/2 MIP LENGTH ** FB12**A FB12**B FB12**C 1/2 FIPX1/2 FIP 1/2 FIPX1/2 MIP 1/2 MIPX1/2 MIP FB58**A FB58**E FB58**D FB58**B FB58**F FB58**H FB58**C FB58**G FB58**I 1/2 FIPX1/2 FIP 3/4 FIPX3/4 FIP 1/2 FIPX3/4 FIP 1/2 FIPX1/2 MIP 3/4 FIPX3/4 MIP 1/2 FIPX3/4 MIP 1/2 MIPX1/2 MIP 3/4 MIPX3/4 MIP 1/2 MIPX3/4 MIP

36 36 Coated Stainless Steel Gas Connectors PART NO. TFB38**A TFB38**D TFB38**E TFB38**B TFB38**F TFB38**C SPECIFICATION 1/2 FIPX1/2 FIP 1/2 FIPX3/8 FIP 3/8 FIPX3/8 FIP 1/2 FIPX1/2 MIP 3/8 FIPX3/8 MIP 1/2 MIPX1/2 MIP LENGTH ** TFB12**A TFB12**B TFB12**C 1/2 FIPX1/2 FIP 1/2 FIPX1/2 MIP 1/2 MIPX1/2 MIP TFB58**A TFB58**E TFB58**D TFB58**B TFB58**F TFB58**H TFB58**C TFB58**G TFB58**I 1/2 FIPX1/2 FIP 3/4 FIPX3/4 FIP 1/2 FIPX3/4 FIP 1/2 FIPX1/2 MIP 3/4 FIPX3/4 MIP 1/2 FIPX3/4 MIP 1/2 MIPX1/2 MIP 3/4 MIPX3/4 MIP 1/2 MIPX3/4 MIP

37 Mechanical Joints & Cutters Male Mechanical Joint PART NO. SPECIFICATION RBJ12MR R1/2 RBJ34MR R3/4 RBJ114MR R1 1/4 RBJ12MG G1/2 RBJ34MG G3/4 Mechanical Coupling PART NO. SPECIFICATION RBJ12x2 1/2 1/2 RBJ34x2 3/4 3/4 Mechanical Tee PART NO. SPECIFICATION RBJ12x3 1/2 1/2 1/2 RBJ34x3 3/4 3/4 3/4 AF12x2/34 1/2 1/2 3/4 AF34x2/12 3/4 3/4 1/2 Female Mechanical Joint PART NO. SPECIFICATION RBJ12G G1/2 RBJ34G G3/4 RBJ1G G1 Coating Cutter PART NO. SPECIFICATION GJ10 1/2, 3/4 Tube Cutter PART NO. SPECIFICATION GJ16 1/2, 3/4, 1 Flanging Cutter PART NO. SPECIFICATION GJ12 1/2, 3/4 37

38 Flexible Gas Connector - Uncoated or Yellow Coated Features: High flexibility and easy installation Bends easily without any cracking Firm welding connection Stable gas flow Good corrosion resistance and long service life PART NO. SIZE ID OD THICKNESS WORKING LENGTH MATERIAL FA12**F FA12**FM FA16**FF FA16**FM (inch) 1/2 3/4 (mm) (mm) (mm) 0.25 PRESSURE (Mpa) 0.5 ** mm 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000, 2500 hose: sus304, sus316, Nut: Brass or stainless steel end: stainless steel Corrugated Extendable Hose - Uncoated or Yellow Coated Features: 100% extendable High performance and suitable for connecting all gas equipment Gas hoses with PVC coating have high protection and good resistance to corrosion PART NO. SIZE ID OD THICKNESS WORKING LENGTH MATERIAL (inch) (mm) (mm) (mm) PRESSURE (Mpa) ** mm FAD12**F FAD12**FM FAD20**FF FAD20**FM 1/2 3/ hose: sus304, sus316, Nut: Brass or stainless steel end: stainless steel 38

39 Stainless Steel Flexible Tube with Braided Wire The inner layer of this flexible hose is stainless steel corrugated tube. The outer layer is stainless steel wire. The superior design allows it to withstand high temperatures and pressures. This hose features excellent reciprocating motion, thermal expansion absorption and vibrating absorption, and an adjusting compound tube center. It can be designed to transport air, steam, oil, water, Stainless Steel Flexible Tube with Braided Wire medicine and more. PART NO. SPECIFICATIONS WORKING THICKNESS Pressure (Mpa) (mm) WJS10FF/FM DN10mm3/ WJS25FF/FM DN25mm LENGTH MATERIAL WJS32FF/FM DN32mm 11/4 with Braided3Wire Stainless Steel Flexible Tube 0.3 the length of hose: sus304, WJS40FF/FM 0.3 hose can be sus316, Nut: Brass or DN50mm 11/2 WJS50FF/FM DN50mm 2 SPECIFICATIONS PART NO. WJS80FF/FM DN80mm Seal Flange WJS40FF/FM DN100mm Seal Flange DN10mm3/8 WJS10FF/FM WJS150FF/FM DN15 0mm Seal Flange WJS25FF/FM DN25mm WORKING 2 Pressure (Mpa) customized THICKNESS LENGTH 1 (mm) stainless steel MATERIAL end: stainless steel WJS32FF/FM DN32mm 11/ the length of hose: sus304, WJS40FF/FM DN50mm 11/ hose can be sus316, Nut: Brass or 0.4 customized stainless steel 16.8WJS50FF/FM - Stainless Steel Regulator Hose 2 DN50mm 2 WJS80FF/FM DN80mm Seal Flange Features: Stainless Steel Regulator Hose WJS40FF/FM DN100mm Seal Flange Use for propane or butane end: stainless steel WJS150FF/FMSPECIFICATIONS DN15 0mm Seal Flange PART NO. Manufactured to BS EN WORKING 1 THICKNESS LENGTH Weld end fittings PRESSURE(Mpa) (mm) (mm) WJS6**HF WJS6**FF M20*1.5 Zero DN6mm permeation -- no smelly hoses DN6mm M20* stainless steel ensure longer service1/14 life compared to rubber hoses W21.8*1 Left hand Thread 450, 750, 1000, 1500 Stainless Steel Regulator Hose PART NO. WJS6**HF WJS6**FF SPECIFICATIONS DN6mm M20*1.5 DN6mm M20*1.5 MATERIAL hose: sus304 Wire: Stainless steel nut: brass end: brass flange: stainless steel WORKING THICKNESS LENGTH PRESSURE(Mpa) (mm) (mm) W21.8*1 1/14 Left hand Thread 450, 750, 1000, 1500 MATERIAL hose: sus304 Wire: Stainless steel nut: brass end: brass flange: stainless steel 39

40 Caravan Hose Features: Manufactured and tested in accordance with BS ISO Material: SUS304, SUS316L Working pressure up to 7 bar Connection to mobile homes Caravan Hose PART NO. SIZE ID OD (inch) (inch) (mm) FC12FM 1/ FC34FM 3/ Caravan 16.10Hose - Gas PART NO. M.I.P. I. 15x1 L=120mm R1/2 * R3/4* THICKNESS WORKING LENGTH (mm) PRESSURE mm Mpa 1000, 1200 or customized Hose: SUS304, SUS316L, M.I.P: stainless steel I: copper MATERIAL 22x1 L=120mm MATERIAL Meter Connector SIZE (inch) Gas Meter Connector Features: FC12FM PART NO. FC34FM END ID OD (inch) (mm) END M.I.P. I. 15x1 1/ R1/2 * L=120mm Manufactured and tested inend SIZE ID OD 3/ R3/4* accordance with BS ISO x1 (inch) (inch) (mm) M.I.P. L=120mm Material: SUS304, SUS316L THICKNESS WORKING LENGTH (mm) PRESSURE mm 0.25 THICKNESS 0.7 Mpa WORKING 1000, 1200 or customized LENGTH (mm) PRESSURE mm 0.5 Mpa 185mm, 390mm 450mm or customized Hose: SUS304, SUS321, SUS316L nut:brass end: stainless steel or carbon steel flange: stainless steel or carbon steel MATERIAL BS 746 Fully welded and 100% pressure Brass But BJ34FM 3/ R3/4* tested before dispatching 0.25mm Connection to gas meters Hose: SUS304, SUS316L, M.I.P:MATERIAL stainless steel I: copper Gas Meter Connector PART NO. SIZE ID OD (inch) (inch) (mm) END M.I.P. THICKNESS WORKING LENGTH (mm) PRESSURE mm 0.5 Mpa 185mm, 390mm 450mm or customized BS 746 BJ34FM 3/ R3/4* Brass But 0.25mm 40 Hose: SUS304, SUS321, SUS316L nut:brass end: stainless steel or carbon steel flange: stainless steel or carbon steel

41 Striker Plates Use: TYPE QSP 1-1/2 WIDE X 3-1/2 LONG TYPE EFSP 2-3/4 WIDE X 13 LONG TYPE FSP 2-3/4 WIDE X 11-1/2 LONG Striker plates protect the tubing from puncture at the area of support Material: Case hardened steel TYPE HSP 2-3/4 WIDE X 6-1/2 LONG TYPE DTSP 2 3/4 -WIDE X 7-1/4 LONG TYPE LSP 3-1/4 WIDE X 17-1/2 LONG Stripwound Conduit Use: Stripwound metal conduit protects the tubing from puncture along tubing runs Material: Galvanized Steel L STRIPWOUND METAL CONDUIT Stub Outs Use: Used to terminate gas piping at appliance or meter Material: Body: Steel APPLIANCE STUB OUT 1/2 AND 3/4 3/4 X6, 1/2 X 6, 1/2 X12, 3/4 X 6, 3/4 X12, 1 X 6, 1 X 12, 1 1/4 X 6, 1 1/4 X 12 FIREPLACE STUB OUT 1/2 X Gas Outlet Box Use: Used to connect gas tubing to appliances Material: Box: Plastic Valve: Brass 41

42 Manifolds Use: Multiport gas distribution. Manifolds supply multiple gas appliances in parallel arrangement from main distribution point. Material: Body: Malleable Iron Tracpipe Manual has nice quality graphics on this 1/2 4 PORT MANIFOLDS 1/2 1/2 3 PORT MANIFOLDS CROSS MANIFOLDS 3/4 1/2 1/2 1/2 1/2 3/4 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 1/2 1 INLETS: OUTLETS: 1 1/2 X 1/2 (6) 1/2 3/ /4 X 3/4 (4) 1/2 and (2) 3/4 1 1 X 3/4 (4) 1/2 and (2) 3/4 1-1/4 X 1 (4) 1/2 and (2) 3/4 2 X 1-1/2 (4) 1 1-1/ Valves Use: Join corrugated stainless steel tubing to npt connection Material: Body: Brass Nut: Brass Retainer: Brass Gasket: Composite Fiber Regular Valve Right-Angle Valve Shut-Off Valves Use: Ball valves shut off the flow of gas at the appliance connection and before the pressure regulator Material: Brass 42

43 CSST System Installation Instructions Technical Data GAS Type & Size 13A 15A 18A 20A 25A 32A CSST (ID) & Dt CSST (OD) & Do Coated layer thickness Outer diameter of coated pipe Nominal Pressure - 0.2MPa Precautions: Always visually inspect the pipe for damage before using it. Take care to avoid damage to the outer layer. Avoid over-bending, which can cause the inner tube to crack or tear. Immediately remove any part of the pipe that is damaged by cutting it out. Keep to the instructions in the training manual. After installation, always conduct a pressure test to eliminate possible leaks. Only LPGA-certified installers are allowed to use the pipe for gas installations Installation Requirements Pre-Installation: Design, construction and final inspection of the installation must be in accordance with the LPGA standards. Keep out of direct sun as CSST coating is not UV resistant. Visually inspects the outer layer to verify it is not damaged, as it protects the inner stainless steel from acid and water with a PH less than 7. Use the correct tools to cut both the inner and outer layer. After cutting the CSST make sure it has no sharp edges that can damage the washer inside the fitting. Use a file (Second Cut File) to remove all the sharp edges that may be caused by the cutter. Remove all filings as they may cause blockings in the gas appliances. Stay within the limits of the prescribed bending radius. (Fig.3) 43

44 44 During Installation: CSST pipe can be used from the source from which the gas is drawn to the appliance that uses the gas. This includes the following; Outside ( Not UV resistant, always cover the tube) Under floor Concrete Inner wall Ceilings Stay within the Bending Radius as indicated below Nominal Diameter 10A, 13A, 15A Minimum Bending Radius (inside radius in inches) 3/4 (0.787) Inside Radius = R 18A, 20A 25A 32A 1 (0.984) 1 1/6 (1`.181) 1 3/5 (1.575) CSST pipe must not be exposed to: Open flames Direct sun (not UV resistant) Space within 6 inches of the appliance or the chimney (excessive heat) Only a single pipe line may run from the control box to an individual gas appliance. Do not T-off to more than one appliance per pipe line. The Control Box is the distribution point from where gas is distributed through a single pipe to all appliances inside the building structure. The control box is always situated outside the building and must have a lock to prevent unauthorized access CSST Characteristics: The corrugated stainless steel tube is manufactured out of high quality stainless steel and the outer layer consists of a fire-resistant polymer composite material. Stainless steel with a high corrosion-resistance content is used that ensures safety and a life span of 50 years or more. The CSST is flexible with a maximun bend of 120 degrees. Available in lengths up to 165 ft. 44

A Pipe as Versatile and Flexible as Your Business

A Pipe as Versatile and Flexible as Your Business A Pipe as Versatile and Flexible as Your Business Multi-Flex Five Layer Composite Pipe: Multi-Flex consist of five layers. All layers are permanently bonded with each other during the production process.

More information

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems UPONOR Ltd Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems Reference Page(s) UPONOR Q&E PEX 2 Operating Conditions 2 Pipe Properties 2 Fittings Range 3 Radiator Heating Systems 3 H&C Water

More information

POTABLE PIPING SYSTEM

POTABLE PIPING SYSTEM POTABLE PIPING SYSTEM Designed Especially for Contractors PRODUCT INSTALLATION GUIDE BOW SUPERPEX JUne 2017 PRODUCT INSTALLATION GUIDE IMPORTANT NOTICE The information in this manual was gathered from

More information

EVALUATION SUBJECT: DIVISION: HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION: HYDRONIC PIPING.

EVALUATION SUBJECT: DIVISION: HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION: HYDRONIC PIPING. ICC-ES Report Reissued 08/2016 This report is subject to renewal 08/2017 EVALUATION SUBJECT: UNIPIPE PEX-AL-PEX DIVISION: 23 00 00 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION: 23 21 13 HYDRONIC

More information

Tube Clamp Submittal Information Revision A: July 25, 2013

Tube Clamp Submittal Information Revision A: July 25, 2013 Tube Clamp Revision A: July 25, 2013 Polypropylene (PP) Tube Clamps secure ½" and ¾" Uponor crosslinked polyethylene (PEX-a) tubing products. Suspension Standard Description Part Number A B C Weight Tube

More information

Potable Piping System

Potable Piping System Page, May 2006 Potable Piping System BOW SUPERPEX is designed with three distinct layers for ultimate protection. The middle layer provides chlorine resistance as well as UV light exposure resistance plus

More information

Improved Chilled Water Piping Distribution Methodology for Data Centers

Improved Chilled Water Piping Distribution Methodology for Data Centers Improved Chilled Water Piping Distribution Methodology for Data Centers By Isabel Rochow White Paper #131 Executive Summary Chilled water remains a popular cooling medium; however leaks in the piping systems

More information

C O D E S & A M M E N D M E N T S

C O D E S & A M M E N D M E N T S SEVIER COUNTY UTILITY DISTRICT SEPTEMBER 2, 2014 Sevier County Utility District has adopted the 2009 International Fuel Gas Code for gas inspections. The following pages contain frequently used codes and

More information

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint. (816) 373-4878 U1208-01/FAI29-029 (573) 751-2624 SECTION 2 105 17 - SLEEVES AND SLEEVE SEALS FOR FIRE-SUPPRESSION PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the

More information

GASEOUS HYDROGEN SYSTEMS

GASEOUS HYDROGEN SYSTEMS CHAPTER 7 GASEOUS HYDROGEN SYSTEMS SECTION 701 GENERAL 701.1 Scope. The installation of gaseous hydrogen systems shall comply with this chapter and Chapters 30 and 35 of the Fire Compressed gases shall

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC AQB09JJ6WC_IM_E_2585 2006.4.17 4:26 PM Page 17 INSTALLATION MANUAL Indoor Unit AQB09JJWC AQB12JJWC Outdoor Unit UQB09JJWC UQB12JJWC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

CSST Flexible Gas Pipe. System Design and Installation Manual

CSST Flexible Gas Pipe. System Design and Installation Manual CSST Flexible Gas Pipe System Design and Installation Manual Suggested Tools for Installation of HOME-FLEX Use to cut HOME-FLEX tubing to desired length. Tubing Cutter Use to remove yellow protective jacket

More information

DUCT SYSTEMS CHAPTER 6

DUCT SYSTEMS CHAPTER 6 SECTION 601 GENERAL 601.1 Scope. Duct systems used for the movement of air in air-conditioning, heating, ventilating and exhaust systems shall conform to the provisions of this chapter except as otherwise

More information

CONNECTION SYSTEM AUGUST Reliance Worldwide USA

CONNECTION SYSTEM AUGUST Reliance Worldwide USA CONNECTION SYSTEM Reliance Worldwide USA AUGUST 2010 1-877-700-4242 www.sharkbitepro.com the sharkbite Connection system includes push-fit and barb products and pex tubing. Contents Introduction and Applications...........................................

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC AQB8J6WC_IM_E_25864 2006.4.4 3:29 PM Page 7 INSTALLATION MANUAL Indoor Unit AQB8J6WC AQB24J2WC Outdoor Unit UQB8J6WC UQB24J2WC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

LINE SET DUCT AND ACCESSORY PRODUCT CATALOG

LINE SET DUCT AND ACCESSORY PRODUCT CATALOG VAC LINE SET DUCT AND ACCESSORY PRODUCT CATALOG Correctly installing an air conditioner requires the use of dedicated accessories. When the customer invests in an air conditioner, he relies on the professional

More information

DUOPEX WATER MANUAL mm

DUOPEX WATER MANUAL mm DUOPEX WATER MANUAL 32-63mm The DUOPEX WATER Pipe and Fitting System is designed for 32mm- 63mm potable hot and cold water applications. This revolutionary alternative for the professional plumber, makes

More information

DESCRIPTION QTY MODEL # ORDER # WT. (lbs)

DESCRIPTION QTY MODEL # ORDER # WT. (lbs) 48 Foamboard Stapler for installing radiant tubing in slab-on-grade or slab-over-slab applications. Foamboard Stapler 1 P667425 81010025 5 Foamboard Staples, 1.5" 300 P667300-300 81000822 3 Foamboard Staples,

More information

CONNECTION SYSTEM Reliance Worldwide USA

CONNECTION SYSTEM Reliance Worldwide USA CONNECTION SYSTEM Reliance Worldwide USA AUGUST 2010 The SharkBite Connection System Includes Push-Fit and Barb Products and PEX tubing. CONTENTS Introduction and Applications...........................................

More information

EUTECTIC EC-10DV Series

EUTECTIC EC-10DV Series EUTECTIC EC-10DV Series DIRECT VENT OIL-FIRED WATER BOILER/NO. 2 OIL VENTING INSTALLATION INSTRUCTIONS CONTENTS..........................................PAGE Basic Guidelines..........................................1

More information

CANADIAN FLEXIBLE GAS PIPING DESIGN GUIDE & INSTALLATION INSTRUCTIONS

CANADIAN FLEXIBLE GAS PIPING DESIGN GUIDE & INSTALLATION INSTRUCTIONS CANADIAN FLEXIBLE GAS PIPING DESIGN GUIDE & INSTALLATION INSTRUCTIONS November 2011 RESIDENTIAL COMMERCIAL INDUSTRIAL FGP-001CAN 11/11 Omega Flex, Inc. TABLE OF CONTENTS Chapter 1 Introduction 1.0 User

More information

SENJU SPRINKLER CO., LTD.

SENJU SPRINKLER CO., LTD. Page:1 of 8 SENJU SPRINKLER CO., LTD. Residential, Pendent Sprinkler Model FR-RES K-Factor: 4.9 SIN: SS4451 GENERAL DESCRIPTION The Model FR-RES Residential Pendent and Recessed Pendent Sprinklers are

More information

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...

More information

DOMESTIC HOT AND COLD WATER SUPPLY AND CENTRAL HEATING SYSTEMS. Guidance Notes

DOMESTIC HOT AND COLD WATER SUPPLY AND CENTRAL HEATING SYSTEMS. Guidance Notes DOMESTIC HOT AND COLD WATER SUPPLY AND CENTRAL HEATING SYSTEMS Guidance Notes 02 DOMESTIC HOT AND COLD WATER SUPPLY AND CENTRAL HEATING SYSTEMS Introduction Plastic pipes are widely used in domestic hot

More information

Heating Installation Guide published by

Heating Installation Guide published by Heating Installation Guide published by MrPEX Systems 2613 87th Court W. Northfield, MN 55057 800-716-3406 mrpexsystems.com mrpex@mrpexsystems.com 2014 MrPEX Systems All rights reserved Printed September

More information

CHAPTER 8 CHIMNEYS AND VENTS

CHAPTER 8 CHIMNEYS AND VENTS CHAPTER 8 CHIMNEYS AND VENTS SECTION 801 GENERAL 801.1 Scope. This chapter shall govern the installation, maintenance, repair and approval of factory-built chimneys, chimney liners, vents and connectors.

More information

Compressed Air Distribution System

Compressed Air Distribution System Compressed Air Distribution System SmartPipe+ from 3/4 to 2-1/2 kaeser.com SmartPipe+ Compressed Air Piping Kaeser s SmartPipe+ is a modular compressed air distribution system that provides both lower

More information

Case Study - Yardley Park Road Gerpex MLCP and Press Fit System, Underfloor Heating and Manifold Based Sanitary Systems

Case Study - Yardley Park Road Gerpex MLCP and Press Fit System, Underfloor Heating and Manifold Based Sanitary Systems Engineered Water Solutions Case Study - Yardley Park Road Gerpex MLCP and Press Fit System, Underfloor Heating and Manifold Based Sanitary Systems www.emmeti.co.uk Site Summary The project, located in

More information

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents Installation Instructions T 9822 Gas Dryer To prevent accidents en - US, CA and appliance damage read these instructions before installation or use. M.-Nr. 07 431 110 2 WARNING For your safety the information

More information

GAS DISTRIBUTION PRODUCTS PA MECHANICAL SADDLES & FITTINGS

GAS DISTRIBUTION PRODUCTS PA MECHANICAL SADDLES & FITTINGS GAS DISTRIBUTION PRODUCTS PA MECHANICAL SADDLES & FITTINGS CONTINENTAL INDUSTRIES ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958

More information

Mechanical Appliance and Equipment Inspection Checklist

Mechanical Appliance and Equipment Inspection Checklist 34 2015 IRC Performing Residential Mechanical s Mechanical Appliance and Equipment Checklist Inspect Mechanical Appliance and Equipment Comments / I. Identify possible mechanical appliance and equipment

More information

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD INSTALLATION OF COMMERCIAL FIRE SPRINKLER SYSTEMS STANDARD #C-001 EFFECTIVE 03-25-2009 PURPOSE: To ensure that sprinkler plans submitted for review contain

More information

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers. SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description Page:1 of 5 SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description The Model ZN-RES Residential Flush Pendent

More information

INSTALLER'S GUIDE. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

INSTALLER'S GUIDE. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES 11-AC11D2-5 INSTALLER'S GUIDE ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES Models: Condensing Units 2A7A5024-048, 2A7A4018-060, 2A7A2018-060 & 2A7A1018-060 IMPORTANT

More information

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes WARM WATER UNDERFLOOR HEATING SYSTEMS Guidance Notes 02 WARM WATER UNDERFLOOR HEATING SYSTEMS Introduction Underfloor heating systems consist of a series of pipes which are integrated into the floor structure

More information

CSST Flexible Gas Pipe. System Design and Installation Manual

CSST Flexible Gas Pipe. System Design and Installation Manual CSST Flexible Gas Pipe System Design and Installation Manual Suggested Tools for Installation of HOME-FLEX Tubing Cutter Use to cut HOME-FLEX tubing to desired length. Note: Turn knob slowly while rotating

More information

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

B.C.S. Shop Heaters 26, 30 & 36 (36 shown) BIOMASS COMBUSTION SYSTEMS, INC. 67 MILLBROOK ST., SUITE 502 WORCESTER, MA 01606 508-798-5970 - FAX 508-798-5971 B.C.S. Shop Heaters 26, 30 & 36 (36 shown) INSTALLATION MANUAL HAND FIRED SYSTEMS 8-09 Biomass

More information

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X INSTALLATION INSTRUCTIONS Cased N, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service,

More information

2012 INTERNATIONAL FUEL GAS CODE VENTS

2012 INTERNATIONAL FUEL GAS CODE VENTS 2012 INTERNATIONAL FUEL GAS CODE SECTION 502 (IFGC) VENTS 502.1 General. All vents, except as provided in Section 503.7, shall be listed and labeled. Type B and BW vents shall be tested in accordance with

More information

TABLE OF CONTENTS Limitations of Authority...6 Table Swimming Pool, Spa, and Hot Tub Permit Fees...7

TABLE OF CONTENTS Limitations of Authority...6 Table Swimming Pool, Spa, and Hot Tub Permit Fees...7 TABLE OF CONTENTS CHAPTER 1 ADMINISTRATION..............1 101.0 General.......................1 101.1 Title..........................1 101.2 Scope........................1 101.3 Purpose......................1

More information

CONNECTION SYSTEM JULY

CONNECTION SYSTEM JULY CONNECTION SYSTEM JULY 2009 IT ALL STARTED WITH A DEEP NEED FOR THE MOST RELIABLE VALVES EVER BUILT. The year was 1893 when the young engineer A.W. Cash was given the toughest challenge of his career:

More information

The intelligent alternative for flue gas venting systems

The intelligent alternative for flue gas venting systems The intelligent alternative for flue gas venting systems FIRST LISTED InnoFlue is the first polymeric vent system tested and listed to ULC-S636 and UL-1738 in North America Intelligent for a good reason

More information

SECTION (15530) - REFRIGERANT PIPING

SECTION (15530) - REFRIGERANT PIPING SECTION 23 23 00 (15530) - REFRIGERANT PIPING PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Tubes. 2. Fittings. 3. Joining Materials. 4. Specialties. B. Related Sections: 1. Section 07 92 00 (07920)

More information

Please Read and Save These Instructions.

Please Read and Save These Instructions. Page 1 of 8 RadonAway Ward Hill, MA. GP500 Fan Installation Instructions Please Read and Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL SERVICE

More information

What You Need to Know about Residential Sprinkler Design

What You Need to Know about Residential Sprinkler Design What You Need to Know about Residential Sprinkler Design Melisa Rodriguez, P.E., NICET IV Design Services Supervisor, Fire Safety melisa.rodriguez@uponor.com www.uponor-usa.com The Residential Sprinkler

More information

Horizontal/Side Discharge Condensing Units

Horizontal/Side Discharge Condensing Units INSTALLATION, OPERATION & MAINTENANCE MANUAL Horizontal/Side Discharge Condensing Units Models CMA12SD-0 CMA18SD-1 CMA24SD-1 CMA30SD-1 CMA36SD-1 CMA48SD-1 517.787.2100 www.marsdelivers.com Horizontal/Side

More information

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design) Page:1 of 5 Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design) General Description The Model HF-RES Residential Flush Horizontal Side-Wall

More information

FACT SHEET 2018 National Fuel Gas Code Summary List of Revisions rev

FACT SHEET 2018 National Fuel Gas Code Summary List of Revisions rev This fact sheet provides an overview of the significant revisions in the 2015 National Fuel Gas Code approved by the National Fuel Gas Code Committee, ANSI ASC Z223 and NFPA 54. These revisions are published

More information

DUOPEX WATER MANUAL mm WM WMKA021044

DUOPEX WATER MANUAL mm WM WMKA021044 DUOPEX WATER MANUAL 32-63mm WM-022149 WMKA021044 The DUOPEX WATER Pipe and Fitting System is designed for 32mm- 63mm potable hot and cold water applications. This revolutionary alternative for the professional

More information

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...

More information

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2 3002239 RSIF 2014-04-04 Installation and operation manual RSIF power venter READ AND SAVE THESE INSTRUCTIONS! Product information Chapters 1 + 2 Mechanical installation Chapter 3 Electrical installation

More information

What Builders Need to Know about Residential Sprinkler Design

What Builders Need to Know about Residential Sprinkler Design What Builders Need to Know about Residential Sprinkler Design Melisa Rodriguez, P.E., NICET IV Design Services Supervisor, Fire Safety melisa.rodriguez@uponor.com www.uponor-usa.com Agenda Brief history

More information

2018 National Fuel Gas Code Summary List of Revisions Updated: 7/27/17

2018 National Fuel Gas Code Summary List of Revisions Updated: 7/27/17 The following list contains a summary of the significant revisions in the 2015 National Fuel Gas Code approved by the National Fuel Gas Code Committee, ANSI ASC Z223 and NFPA 54. 1.1.1.1 (B), (C), & (D)

More information

SECTION (15530) - REFRIGERANT PIPING

SECTION (15530) - REFRIGERANT PIPING PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Tubes. 2. Fittings. SECTION 23 23 00 (15530) - REFRIGERANT PIPING 3. Joining Materials. 4. Specialties. B. Related Sections: 1.02 REFERENCES 1. Section

More information

Making Crimp Connections

Making Crimp Connections Making Crimp Connections Cut tube off square (90 ) with a tube cutter. Tube Cutter Slide the PEX crimp ring over the end end of the tube. BE SURE the crimp ring is centered over the PEX barb. Slide the

More information

BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS

BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used by

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

EHH SERIES DRAW THROUGH FAN COILS CFM

EHH SERIES DRAW THROUGH FAN COILS CFM EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE

More information

Socket Heat Fusion Techniques. A Guide for Instruction and Training in Vanguard Socket Heat Fusion

Socket Heat Fusion Techniques. A Guide for Instruction and Training in Vanguard Socket Heat Fusion Socket Heat Fusion Techniques A Guide for Instruction and Training in Vanguard Socket Heat Fusion TABLE OF CONTENTS This brochure has been developed to assist those responsible for socket fusion joining

More information

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings. DIVISION 21 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, sleeves, escutcheons, seals, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS

More information

Installation Instructions

Installation Instructions CNPHP Cased N Coils Horizontal Heating --- Cooling NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...

More information

Residential Lead Free Flat Concealed Sprinkler, Pendent, Model: RC-RES, K-Factor: 4.9, SIN: SS8461

Residential Lead Free Flat Concealed Sprinkler, Pendent, Model: RC-RES, K-Factor: 4.9, SIN: SS8461 Page:1 of 8 Residential Lead Free Flat Concealed Sprinkler, Pendent, Model: RC-RES, K-Factor: 4.9, SIN: SS8461 GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

Secondary systems used in Europe.

Secondary systems used in Europe. Secondary systems used in Europe. Production Distribution Consumption Preface Secondary systems are the parts of the heating systems with a lower pressure and temperature level, installed in buildings.

More information

LINE SET DUCT AND ACCESSORY PRODUCT CATALOG

LINE SET DUCT AND ACCESSORY PRODUCT CATALOG VAC LINE SET DUCT AND ACCESSORY PRODUCT CATALOG Correctly installing an air conditioner requires the use of dedicated accessories. When the customer invests in an air conditioner, he relies on the professional

More information

Installation Instructions

Installation Instructions Installation Instructions 30" ELECTRIC Downdraft Cooktop Modules selected at time of purchase IMPORTANT: Read and save these instructions. Part No. 208040 A 438589 Quick Reference Table of Contents: Pages

More information

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA Navien America Inc. Specification Details for the Navien models: CR-210 CR-210A For Indoor Installation Only For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA,

More information

ZoomLock TM Flame-Free Refrigerant Fittings

ZoomLock TM Flame-Free Refrigerant Fittings ZoomLock TM Flame-Free Refrigerant Fittings Form P-528, Engineering Specification, February 2018 FLAME-FREE REFRIGERANT FITTINGS Page 2 / ZoomLock Engineering Specification PART 1: GENERAL 1.0 SUMMARY

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

SENJU SPRINKLER CO., LTD.

SENJU SPRINKLER CO., LTD. Page:1 of 8 SENJU SPRINKLER CO., LTD. Residential Lead Free Flat Concealed Sprinkler, Pendent, Model: RC-RES, K-Factor: 4.9, SIN: SS8464 GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed

More information

Commercial Flat Concealed Sprinkler, Pendent, Quick Response, Extended Coverage (Light Hazard) Model: RC-QR-EC, K-Factor: 5.

Commercial Flat Concealed Sprinkler, Pendent, Quick Response, Extended Coverage (Light Hazard) Model: RC-QR-EC, K-Factor: 5. Page:1 of 6 Commercial Flat Concealed Sprinkler, Pendent, Quick Response, Extended Coverage (Light Hazard) Model: RC-QR-EC, K-Factor: 5.6, SIN: SS3561 GENERAL DESCRIPTION The Model RC-QR-EC Commercial

More information

DUCT SYSTEMS CHAPTER 6

DUCT SYSTEMS CHAPTER 6 CHAPTER 6 DUCT SYSTEMS SECTION 601 GENERAL 601.1 Scope. Duct systems used for the movement of air in air-conditioning, heating, ventilating and exhaust systems shall conform to the provisions of this chapter

More information

Special Provision No. 683S28 December 2017

Special Provision No. 683S28 December 2017 FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE - Item No. FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE (TEMPORARY) - Item No. Special Provision No. 683S28 December 2017 1. SCOPE

More information

Vent Kit for Condensing Tankless Gas Water Heater

Vent Kit for Condensing Tankless Gas Water Heater Installation Manual NORITZ AMERICA CORPORATION Vent Kit for Condensing Tankless Gas Water Heater Model: EZ2FVK-1 (Flex Vent 2" Kit 25 feet) Potential dangers from accidents during installation and use

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET General Piping Recommendations and Refrigerant Line Length for Split-System Air Conditioners and Heat Pumps GENERAL GUIDELINES This Split-System (Air Conditioning Condensing/Heat

More information

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION CONDITIONERS DRY CHARGE UNITS PRODUCT SPECIFICATIONS Bulletin No. 20636 May 204 Supersedes March 202.5 to 5 Tons MODEL NUMBER IDENTIFICATION L C S 3 DC - 036-230 - 2 Lennox Minor Revision Number Air Conditioner

More information

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU) AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory

More information

Installation Instructions

Installation Instructions Installation Instructions KFN 9855 ide en - CA Installation, repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations

More information

Installation Instructions

Installation Instructions Installation Instructions Type B Gas Vent Model E/R 3" 8" ECCO TYPE B GAS VENT AND ACCESSORIES ARE FOR USE ONLY WITH LISTED CATEGORY 1 GAS-FIRED APPLIANCES OR APPLIANCES LISTED FOR USE WITH TYPE B GAS

More information

Technical Checklist - Plumbing and Heating Fittings - UK Sizes

Technical Checklist - Plumbing and Heating Fittings - UK Sizes Technical Checklist - Plumbing and Heating Fittings - UK Sizes July 2008 NOTE: This checklist refers exclusively to fittings and accessories from our range of push-fit products for Plumbing and Heating

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH TXV Horizontal Slab Coils WLSH These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

RESCOM 2100 HOT WATER BASEBOARD RADIANT HEATING Unique, slim-design baseboard radiators

RESCOM 2100 HOT WATER BASEBOARD RADIANT HEATING Unique, slim-design baseboard radiators RESCOM 2100 HOT WATER BASEBOARD RADIANT HEATING www.b Unique, slim-design baseboard radiators The RESCOM 2100 system is unlike traditional baseboard heating systems. Smooth flat panels are easily secured

More information

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data W A T L O W The Watlow FIREROD not only set the industry standard for cartridge heaters, it continues making improvements in construction and design. Among those improvements is the metric FIREROD, a variation

More information

Inspection Checklist Mechanical Rough in

Inspection Checklist Mechanical Rough in Property Owner Name: Property Address: Permit Number: Inspectors Name: Review Date: Permits and Plans 1. Job address is posted in a visible location. (R319.1) 2. Permit and approved plans are on site and

More information

Installation Instructions

Installation Instructions Installation Instructions Downdraft Vent Systems PVB94 PVB98 ZVB30 ZVB36 31-10728-8 11-14 GE 1 Safety Information If you have questions, call 800.GE.CARES or visit our website at: GEAppliances.com BEFORE

More information

PLUMBING CURRICULA OUTLINE

PLUMBING CURRICULA OUTLINE PLUMBING CURRICULA OUTLINE CORE CURRICULUM 2015 Basic Safety (Construction Site Safety Orientation) (12.5 Hours) (Module ID 00101-15) Presents basic jobsite safety information to prepare workers for the

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description Technical Services 800-381-9312 +1-401-781-8220 www.tyco-fire.com Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description The TYCO Model ESFR-17 Dry

More information

Vertical Stack Fan Coil Units Models: TVA, TVE, TVS

Vertical Stack Fan Coil Units Models: TVA, TVE, TVS 6720 Columbus Road Mississauga, Ontario Canada, L5T 2G1 Tel: (905) 670 3595 Fax: (905) 670 3592 www.temspec.com Vertical Stack Fan Coil Units Models: TVA, TVE, TVS INSTALLATION, OPERATION AND MAINTENANCE

More information

INSTALLATION MANUAL UN-CASED A COILS UPFLOW FOR COOLING/HEAT PUMPS FLEX COILS FOR FIELD INSTALLED TXV MODELS: UC LIST OF SECTIONS LIST OF FIGURES

INSTALLATION MANUAL UN-CASED A COILS UPFLOW FOR COOLING/HEAT PUMPS FLEX COILS FOR FIELD INSTALLED TXV MODELS: UC LIST OF SECTIONS LIST OF FIGURES INSTALLATION MANUAL UN-CASED A COILS UPFLOW FOR COOLING/HEAT PUMPS FLEX COILS FOR FIELD INSTALLED TXV MODELS: UC ISO 9001 Certified Quality Management System SAFETY................................................

More information

Installation Manual. Vent Kit for Condensing Tankless Gas Water Heater

Installation Manual. Vent Kit for Condensing Tankless Gas Water Heater Installation Manual NORITZ AMERICA CORPORATION Vent Kit for Condensing Tankless Gas Water Heater Model: N-FlexKit2"-35 Applicable Model NRC663-FSV Potential dangers from accidents during installation and

More information

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS I-VICFLEX.AB Victaulic VicFlex Style AB Sprinkler Fitting for Hat Furring Channel Ceiling Systems Read and understand all instructions before attempting to install any Victaulic

More information

Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor General Description

Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor General Description Technical Services 800-381-9312 +1-401-781-8220 www.tyco-fire.com Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor General Description Pendent Sprinklers (TY2524) are decorative,

More information

Installation Instructions

Installation Instructions CNPVP CNRVP Cased N Coils Upflow --- Downflow Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

More information

Hospitals and Major Medical Centers

Hospitals and Major Medical Centers Hospitals and Major Medical Centers INERGEN Fire Suppression Systems AUTOPULSE Detection and Control Equipment SENTRY Hand Portable Fire Extinguishers Medical centers have special concerns for fire safety

More information

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS 230500 HVAC BASIC MATERIAL AND METHODS PART 1 GENERAL 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS A. Section 230000 Basic HVAC Requirements B. Section 230523 Valves C. Section 230510 Chilled

More information

IFGC-2012 AMENDED IFGC-2015 IFGC-2018 CHAPTER 1 SCOPE AND

IFGC-2012 AMENDED IFGC-2015 IFGC-2018 CHAPTER 1 SCOPE AND CHAPTER 1 SCOPE AND CHAPTER 1 SCOPE AND ADMINISTRATION ADMINISTRATION 301.1.2 LP-Gas installations. Whenever there is a conflict between this code and NFPA 54 and B+NFOA 58 as adopted by the Nevada LP-Gas

More information

REFRIGERANT PIPING SYSTEM

REFRIGERANT PIPING SYSTEM PART 1 GENERAL 1.01 DESCRIPTION A. The requirements of this section apply to the refrigerant piping system connecting refrigeration and HVAC equipment specified in other sections of these specifications.

More information

Residential Flat Concealed Sprinkler, Pendent, Model: CN-RES, K-Factor: 4.9, SIN: SS8421

Residential Flat Concealed Sprinkler, Pendent, Model: CN-RES, K-Factor: 4.9, SIN: SS8421 Page:1 of 7 Residential Flat Concealed Sprinkler, Pendent, Model: CN-RES, K-Factor: 4.9, SIN: SS8421 GENERAL DESCRIPTION The Model CN-RES Residential Flat Concealed Sprinklers are automatic sprinklers

More information