EC Motor Fan Coil Units. IMDL-Y Series l/s

Size: px
Start display at page:

Download "EC Motor Fan Coil Units. IMDL-Y Series l/s"

Transcription

1 C Motor Fan Coil Units IMDL-Y Series l/s

2 Temperzone s Fan Coil History Company Profile Temperzone Limited is a leading manufacturer and distributor of quality air conditioning and ventilation products throughout the Western Pacific Rim. Corporate Head Office is located in New Zealand with factories in Auckland and Sydney. A network of offices, warehouses and distributors provide local support and representation in Australasia, South ast Asia and China. temperzone s aim is to provide the most competitively priced, reliable and efficient air conditioning equipment available to the international market. A privately owned company, temperzone Holdings Ltd, is the parent company of temperzone ltd (est.956) in Auckland and temperzone Australia pty ltd in Sydney. The wide range of temperzone products are manufactured in Auckland for markets in Australasia and Asia. This range includes air distribution items and fans for New Zealand. The Sydney headquarters acts as both a distribution centre and manufacturer of customised and larger standard air conditioning units specifically for Australia. temperzone s Asia Regional Head Office is located in Singapore. The combined group operations employ over 500 staff. Temperzone have been manufacturing chilled water fan coil units for more than 5 years. The original RCMC units were superseded in the mid 980 s with a new breed of RCMC which were then superseded in the late 990 s with the IMDL range. Prior to the development of temperzone s C motor fancoils, units had all been manufactured with fixed single speed or multi-speed PSC motors. Any changes in the cooling or heating performance had been solely on the basis of varying the water flow by way of a 2-way or -way water regulating/ modulating valve. With the indoor fan running on a constant speed. This left considerable room for improvement in designing higher efficiency models. It is time now to take a step forward with the new IMDL Y version with high efficiency C (lectronically Commutated) motors. C motors allow for the air flow to be controlled over a wider range either by the multiple speeds that are available or by the use of a 0 0V dc variable signal. Speeds as high as 500 rpm and as low as 500 rpm are available by dip switch selection in multi-speed or variable voltage signal. By utilising the C motor technology it is no longer necessary to have the S, M and H models, one model size suits all with the required speed range selected by dip switches Key Features nergy fficient C Motor Significant nergy Savings Independent Fan Operation On-site Adjustable Fan Air Volume Controller Remote Fan Air Volume Adjustment Capability from BMS. 2

3 IMDL-Y Fan Coil Units GNRAL Fan coil units are an integral part of an overall air conditioning system where the energy transfer medium (i.e. chilled or hot water) is circulated by a central plant facility. temperzone offers an extensive range of ducted fan coil units. A variety of options and accessories are available to meet most air conditioning requirements. Low operating cost, energy efficient fan motors are used in all units. asy installation and maintenance add to the cost effectiveness of temperzone IMDL Series fan coil units. All IMDL fan coil units can be handed left or right. Unless otherwise ordered units will be supplied right handed which is the standard handing, i.e. when facing the discharge side of the unit, the water and electrical connections are on the right hand side. TYPICAL APPLICATIONS Office Buildings The low overall height of 260 mm makes them ideally suited to office building applications where false ceiling space is at a premium. Hotels IMDL units are extremely well suited for individual room control. A standard above ceiling installed unit with speed control (available option) is normally used for this type of application. Airport Terminal Buildings temperzone fan coil units are gaining worldwide popularity in airport terminals. These complexes generally consist of a number of areas with very diverse occupancy and capacity requirements. Hospitals The majority of hospital rooms must have a separate and independent air conditioning system. This is to avoid bacterial cross contamination. temperzone fan coil units have been used successfully in these applications. STANDARD FATURS Drain Tray The drain tray is plastic and is removable for ease of cleaning and can be adjusted to slope when the unit is installed level. Motors High efficiency electronically commutated (C) motors are fitted as standard on all units. Motors can be operated on three speeds (site changable) or 0-00% capacity using a 0-0V dc signal supplied by a BMS or sophisticated controller. The motors are resiliently mounted, self aligning and oiled for life. Fans Quiet low line, centrifugal type, double width, statically and dynamically balanced, multi-bladed impellers are used. The position and shape of the fan blades and housing has been developed after extensive testing to achieve minimum noise levels while maintaining a smooth pressure vs air flow curve. Coils Coils are manufactured in rifled copper tubing. All coils are thoroughly tested to 200 kpa. Coil rows are staggered for maximum heat exchange. Three different coil configurations are available refer table on page 5. The coil fins are manufactured as a continuous plate, die formed from epoxy aluminium with a smooth corrugated surface, specially designed to overcome and prevent lint build up. The coil fins are mechanically bonded to the copper tubing which results in a rigid assembly and provides a permanent metallic contact between fins and tube for maximum heat transfer. Casing The casing is manufactured from high quality galvanised steel and internally insulated. Insulation Closed cell foam insulation has been used in the cabinet to ensure no particles are introduced into the air stream. The insulation is foil faced and meets the fire test standards AS 50. (989) and BS 76 parts 6 and 7. Open cell foam is used in the return air section for noise attenuation. LCTRICAL BOX Wiring from the motors terminate in a terminal block in a sheetmetal enclosed electrical box. The box is supplied on the same side as the water connections, but can be changed on site to the opposite side. STANDARD OPTIONS. Return Air Plenum (insulated) with Filter -- filter is mm thick, washable and rated U2. 2. Multi-Outlet Supply Air Insulated Spigot -- sized to suit flexible ducting.. lectric Heat -- stainless steel finned element -- mounted within the unit -- factory fitted -- complete with automatic and manual high temperature safety cutout thermostats required to meet AS/NZS seconds fan run-on time (for heat dissipation) is built into the motor driver board and selected by dip switch. -- Variable capacity control of electric heat via solid state relay (SSR).. Control switches -- on/off and speed rotary switches mounted in a standard or architrave type flush plate. WIRING The electrical supply required (including voltage fluctuation limits) is: phase V a.c. 50 Hz with neutral and earth. ach IMDL unit is fully wired ready to accept the main power supply. ORDR DTAIL Coil Options: - Three row coil for cooling - Four row coil for cooling / - Three row cooling / one row heating - Three row cooling coil + electric heat - Four row cooling coil + electric heat Note: Please specify on your order the size, fan motor type and coil option using the above codes. IMDL * Y- xamples: IMDL 0Y-/ IMDL 60Y- Series Size Coil Option

4 TCHNOLOGY VAV For the last 0 years virtually all fan coil units have operated with a constant fan speed and therefore constant air volume (CAV). Temperature changes in these units were achieved by the water valve, i.e. varying the water volume. With this design, energy was wasted due to fans constantly running at full speed, regardless of the requirement of the thermal zone served. With temperzone s new range of VAV fan coil units, varying air volume results in greater efficiency. Controls The new C motor version IMDL units allow for several methods of control allowing great flexibility to meet the demands of modern buildings expectations. The fan speed could be adjusted for instance as the first step of capacity control before adjusting water flow. Three Speed Selection The fans can be controlled just like their predecessors using three speed selection, high, medium and low. This option is selectable by dip switch and then by using further dip switch settings to select from the available speed ranges that are most suitable for the application. Potentiometer The fans could also be controlled by the fitting of a potentiometer to preset the required speed. This will be particularly useful during onsite commissioning to be able to adjust to obtain the desired air flow. Indoor Fan Speed The indoor fan speed can be Stepped or Continuously Variable. The maximum and minimum operating speeds are decided by the setting of dip switches on the PCB found in the electrical box.. Stepped ( Speed) If using a speed selection switch, the medium speed will always be half way between the maximum (High) and minimum (Low) speeds as selected using the DIP switch & 5 settings. 2. Continuously Variable (0-0V Control) If using a variable 0 0V dc signal (from the BMS or sophisticated controller) then the DIP switch & 5 settings will limit the maximum and minimum speeds/voltages. The fans will not operate until a signal above V is received and will then start at the minimum voltage/speed set using DIP switch & 5. The 0V signal input equates to the maximum volts set on DIP swithes,2 &. Control voltages between these two limits can be used to achieve any desired speed between Min. and Max. rpm. With the Factory Settings (refer above) a signal voltage of between 2V and 0V will be limited to proportion the signal to the motor/s between.2v and 8.7V. Note: Only one control method must be connected at any one time; either Stepped speed control or Variable 0-0V dc, not both. If the input signal drops below 0.7V DC, the fan will run on for either 0 or 20 seconds, dependant on the DIP switch 6 setting, before stopping. If electric heat is fitted, ensure that DIP switch 6 is set for 20 seconds. BMS Many modern buildings these days have Building Management Sytems (BMS) and it is most desirable to control the fan speed variably to meet the building s load demands. The unit can accept a 0-0Vdc signal from the BMS or other sophisticated controller. This option is again selectable by dip switch and likewise so is the allowable speed range. The BMS can be programmed to achieve various beneficial functions such as; maintaining high air flow when on heating first thing in the morning to avoid stratification within the space, reducing the air flow down to say 50 to 60% as a capacity control method prior to adjustment of the water flow. C Motors Brushless C motors within the fan coil units provide a cooler running motor emitting less heat into the supply air. This is achieved as energy savings reduce the fan power to almost a quarter of a comparable PSC motor. The life expectancy of an C motor can be up to twice as long as a comparable PSC motor due to functions such as the soft start which eliminate stress to the mounting bracket or hardware. This improved life expectancy further benefits the building owner by a reduction in maintenance costs.

5 Specification Model IMDL 0Y IMDL 60Y IMDL 90Y IMDL 0Y Nominal Air Flow High 60 Pa external static (l/s) * Fan type forward curved centrifugal double inlet double width No. of fan scrolls 2 2 Motor type Power Source ** lectronically Commutated (C) DC direct drive Phase 20 VoltAC 50 Hz No. of motors 2 Motor Rating (W) Full Load Amps (A) (.2) lectric Heating (kw) *** Max. Current with lectric Heat (A) Heat xchanger type Cooling/Heating Medium Options Finish Test aluminium corrugated plate fins to expanded rifled copper tube chilled water or hot water rows cooling + row heating or rows cooling or rows cooling + electric heat zinc galvanised steel 200 kpa Connection Sizes Cooling Coil (mm) 20 BSP Male (/ ) 25 BSP Male ( ) Connection Sizes Heating Coil (mm) 5 BSP Male (/2 ) Air Filter Type washable G2 / U2 (supplied Standard) No. of Air Filters 2 Air Filter Size (mm) 55 x 2 x 795 x 2 x 05 x 2 x 725 x 2 x Static to allow for Air Filter (Clean) at Nominal Air Flow (Pa) Static to allow for wet surface coil (Pa) 6 8 Weight (/ row, incl. water) (kg) Nett Weight (excl. water) (kg) Shipping Weight approx. (kg) Notes: - * With no filters fitted and with a dry coil surface ** Voltage fluctuation limits V *** Option Only - Solid state relay control for variable capacity. Summary of Choices Size 0 / 60 / 90 / 0 Cooling and Heating Coil Configurations Fan Run On Timer Multi S/A Spigot Handing Rows Cooling + Row Heating Rows Cooling Rows Cooling + lectric Heating C motor driver has in built run on timer for all models 0sec. approx. and selectable to 20sec. when fitting electric heating. Optional xtra Right (Standard) / Left 5

6 IMDL 0Y Cooling Capacity kw ntering Air Temperature 2.0 C db 7.0 C wb Nominal Air Flow 200 l/s ntering Temperature C ntering Air Temperature 2.0 C db 7.0 C wb Air Flow 70 l/s ntering Temperature C ntering Air Temperature 2.0 C db 7.0 C wb Flow l/s Air Flow 50 l/s ntering Temperature C Heating Capacity lectric Heating Option.5 kw ntering Air Temperature 2.0 C db Nominal Air Flow 200 l/s ntering Temperature C ntering Air Temperature 2.0 C db ntering Temperature C ntering Air Temperature 2.0 C db ntering Temperature C Air Flow 70 l/s Air Flow 50 l/s

7 IMDL 0Y Air Handling l/s - Pa 8V 7V 6V 5V V l/s - W Note: Airflows are for dry coil. Reduce airflow by 0% in high moisture removal conditions. Air flows given are for IMDL-Y units without filter installed. Refer page 8 for filter pressure drop A 0.86A.9A A 8V A 7V 6V 60 5V 0 V A 0.7A 0.88A.9A.9A Nominal Face Velocity 2.5 m/s Test Conditions: BS 88 PT2 985 Sound Levels Installation Type A (free inlet and outlet) Direct method of measurement (reverberant room) Return Air Inlet + Case Breakout Measured in decibels re picowatt Octave Band Frequency Hz Vdc Sound Power K SWL db(a) Sound Power Levels (SWL) db 2K K * Supply Air Outlet Vdc Octave Band Frequency Hz Sound Power K SWL db(a) Sound Power Levels (SWL) db 2K K * *Nominal 7

8 IMDL 60Y Cooling Capacity kw ntering Air Temperature 2.0 C db 7.0 C wb Nominal Air Flow 0 l/s ntering Temperature C ntering Air Temperature 2.0 C db 7.0 C wb Air Flow 00 l/s ntering Temperature C ntering Air Temperature 2.0 C db 7.0 C wb Air Flow 250 l/s ntering Temperature C Heating Capacity lectric Heating Option 2.0 kw ntering Air Temperature 2.0 C db Nominal Air Flow 0 l/s ntering Temperature C ntering Air Temperature 2.0 C db ntering Temperature C ntering Air Temperature 2.0 C db ntering Temperature C Air Flow 00 l/s Air Flow 250 l/s 8

9 IMDL 60Y Air Handling l/s - Pa 7V l/s - W 280 0V 25 8V Note: Airflows are for dry coil. Reduce airflow by 0% in high moisture removal conditions. Air flows given are for IMDL-Y units without filter installed. Refer page 8 for filter pressure drop. 6V 05 V 5V A 0.67A 0.5A A 0V 00 8V A 7V 60 6V 0 0.8A 5V V.70A A 0.9A 0.7A.0A.9A Nominal Face Velocity 2.5 m/s Test Conditions: BS 88 PT2 985 Sound Levels Installation Type A (free inlet and outlet) Direct method of measurement (reverberant room) Return Air Inlet + Case Breakout Measured in decibels re picowatt Octave Band Frequency Hz Vdc Sound Power K SWL db(a) Sound Power Levels (SWL) db 2K K * Supply Air Outlet Vdc Octave Band Frequency Hz Sound Power K SWL db(a) Sound Power Levels (SWL) db 2K K * *Nominal 9

10 IMDL 90Y Cooling Capacity kw ntering Air Temperature 2.0 C db 7.0 C wb Nominal Air Flow 00 l/s ntering Temperature C ntering Air Temperature 2.0 C db 7.0 C wb Air Flow 50 l/s ntering Temperature C ntering Air Temperature 2.0 C db 7.0 C wb Air Flow 290 l/s ntering Temperature C Heating Capacity lectric Heating Option.0 kw ntering Air Temperature 2.0 C db Nominal Air Flow 00 l/s ntering Temperature C ntering Air Temperature 2.0 C db ntering Temperature C ntering Air Temperature 2.0 C db ntering Temperature C Air Flow 50 l/s Air Flow 290 l/s 0

11 IMDL 90Y Air Handling l/s - Pa l/s - W 0V 20 8V Note: Airflows are for dry coil. Reduce airflow by 0% in high moisture removal conditions. Air flows given are for IMDL-Y units without filter installed. 7V 50 Refer page 8 for filter pressure drop. 6V 20 V 5V A 0.97A A 0.5A 0V A 0.8A 5V 6V 7V 8V 20 V 0.2A 0.5A 0.8A.0A.8A.69A Nominal Face Velocity 2.2 m/s Test Conditions: BS 88 PT2 985 Sound Levels Installation Type A (free inlet and outlet) Direct method of measurement (reverberant room) Return Air Inlet + Case Breakout Measured in decibels re picowatt Octave Band Frequency Hz Vdc Sound Power K SWL db(a) Sound Power Levels (SWL) db 2K K 0* Supply Air Outlet Vdc Octave Band Frequency Hz Sound Power K SWL db(a) Sound Power Levels (SWL) db 2K K 0* *Nominal

12 IMDL 0Y Cooling Capacity kw ntering Air Temperature 2.0 C db 7.0 C wb Nominal Air Flow 650 l/s ntering Temperature C ntering Air Temperature 2.0 C db 7.0 C wb Air Flow 525 l/s ntering Temperature C ntering Air Temperature 2.0 C db 7.0 C wb Air Flow 25 l/s ntering Temperature C Heating Capacity lectric Heating Option.0 kw ntering Air Temperature 2.0 C db Nominal Air Flow 650 l/s ntering Temperature C ntering Air Temperature 2.0 C db ntering Temperature C ntering Air Temperature 2.0 C db ntering Temperature C Air Flow 525 l/s Air Flow 25 l/s 2

13 IMDL 0Y Air Handling l/s - Pa 6V 7V l/s - W 00 0V 8V Note: Airflows are for dry coil. Reduce airflow by 0% in high moisture removal conditions. Air flows given are for IMDL-Y units without filter installed. Refer page 8 for filter pressure drop. 5V 50 V A.92A 0 80.A A 20 0V 00 8V 0.67A 7V 80 6V A 5V 0 V 2.6A A 0.7A.2A.72A 2.A Nominal Sound Levels Return Air Inlet + Case Breakout Vdc Sound Power SWL db(a) Octave Band Frequency Hz K 2K K Sound Power Levels (SWL) db * Supply Air Outlet Vdc Sound Power SWL db(a) Face Velocity 2. m/s Octave Band Frequency Hz K 2K K Sound Power Levels (SWL) db Test Conditions: BS 88 PT2 985 Installation Type A (free inlet and outlet) Direct method of measurement (reverberant room) Measured in decibels re picowatt * *Nominal

14 DIMNSIONS (mm) - Right hand models shown (not to scale) IMDL 0Y IMDL 60Y MTG CTR LCTRICAL BOX MOUNTING CNTRS LCTRICAL BOX 75 OVRALL 25 MTG CTR 222 MTG CTR DRAIN 9 OD 25 MTG CTR 75 OVRALL 222 MTG CTR DRAIN 9 OD S/A SPIGOT SUPPLY AIR SPIGOT 52 x 70 WATR CONN'S SUPPLY AIR SPIGOT 762 x 70 WATR CONN'S 255 OVRALL OUT IN 255 OVRALL OUT IN 687 OVRALL 97 OVRALL IMDL 90Y MOUNTING CNTRS Connections IMDL Cooling Heating 0Y 20 BSP Male (/ ) BSP Male (/2 ) 60Y 20 BSP Male (/ ) BSP Male (/2 ) 90Y 25 BSP Male ( ) BSP Male (/2 ) 0Y 25 BSP Male ( ) BSP Male (/2 ) 25 MTG CTR 77 OVRALL 262 MTG CTR LCTRICAL BOX DRAIN 9 OD 50 SUPPLY AIR SPIGOT 02 x OVRALL S/A SPIGOT OUT IN WATR CONN'S 9 OVRALL

15 IMDL 0Y 57 2 MOUNTING CNTRS LCTRICAL BOX 77 OVRALL 25 MTG CTR 262 MTG CTR DRAIN 9 OD OVRALL SUPPLY AIR SPIGOT 2 x 79 S/A SPIGOT WATR CONN'S OUT IN 59 OVRALL OPTIONAL SUPPLY AIR SPIGOTS 00 Model IMDL 0Y IMDL 60Y IMDL 90Y IMDL 0Y Spigots 200 dia (x2) 250 dia (x2) 250 dia (x) 250 dia (x) SPIGOTS TO SUIT FLXIBL DUCTING 5

16 WIRING DIAGRAM: IMDL 0Y-0Y A B C D F G 0 2 Speed Setting OFF ALC DIP Switch Settings FACTORY STTING OFF ON Speed Setting ON 20//50 Supply Client Protection & Isolation Switch L A N Blue Brown Green N L FAN Red White Yellow Blue Speed Range Without lectric Heat LAV IN THIS POSITION Speed Range With lectric Heat (0s Fan run on) (20s Fan run on) LAV IN THIS POSITION DO NOT US DIP Switch Settings DO NOT US Speed Setting MAX Vdc Speed Range Vdc Client Supplied. On/Off Control OR 2. Timeclock On/Off TH TH2 Blue Brown Green N L FAN2 Red White Yellow Blue FAN2 IN IMDL0Y ONLY NOT: Minimum active voltage out limited to 2.2V DC unless off. DIP Switch Refer table for settings ALC INPUTS OUTPUT M H +V +V 0V Out Com L 0V In Above Speed Setting sets the max. speed/voltage (HIGH). Above Speed Range sets the difference between the max. speed and the min. speed/voltage (LOW). With the speed control the medium speed is always halfway between HIGH and LOW. NOT: Do NOT connect BOTH speed L/M/H switch and also 0-0V (DC) signal. Only ON control method may be connected at a time. If in doubt ask! Alternative speed switch LOW MD HIGH L M H COM TB5 TB ALC 0-0V Limit Controller FAN Impeller Assembly 6 Diameter FAN2 Impeller Assembly 6 Diameter PR Power Relay 0-0V (DC) Signal from BMS or other controller 0V 0-0V TACHO FAN TACHO FAN2 0V 0-0V TACHO TACHO2 TB RV MODIFICATION DAT CN APVD Corrected Mains terminal sequence on motors; new control loom (removed terminal joiner); removed 0V DC available N897 L.O.L. Removed 0V DC available; Revised note; New relay between Fan and L, all pin numbers revised N897 L.O.L. temperzone Ltd 205 DO NOT SCAL - ASK Client Wiring Drawn: Apprvd: M.A.H. Date: 8/06/205 Model Fan full load current (FLA) IMDL0Y IMDL60Y IMDL90Y IMDL0Y.A.8A.8A.2A Title: Drawing No: Rev: IMDL 0Y-0Y lectrical Wiring Schematic SHT OF

17 WIRING DIAGRAM: IMDL 0Y-0Y (c/w lectric Heat) A B C D F G 0 2 OFF ALC DIP Switch Settings FACTORY STTING OFF ON ON 20//50 Supply Client Protection & Isolation Switch F L L A F Blue Brown Green F N L FAN Red White Yellow Blue F Speed Setting Speed Setting N N Speed Range Speed Range Without lectric Heat With lectric Heat (0s Fan run on) (20s Fan run on) LAV IN THIS POSITION DO NOT US LAV IN THIS POSITION DO NOT US 8 DIP Switch Settings Speed Setting MAX Vdc Speed Range Vdc. On/Off Switch OR 2. Timeclock On/Off TH Blue Brown Green F N L FAN2 IN IMDL0Y ONLY FAN2 Red White Yellow Blue F NOT: Minimum active voltage 0 9. out limited to 2.2V DC 0 unless off. Above Speed Setting sets the max. speed/voltage (HIGH). Above Speed Range sets the difference between the max. speed and the min. speed/voltage (LOW). With the speed control the medium speed is always halfway between HIGH and LOW. NOT: Do NOT connect BOTH speed L/M/H switch and also 0-0V (DC) signal. Only ON control method may be connected at a time. If in doubt ask! 2 Alternative speed switch NOT: Do NOT apply HAT signal if the FAN is NOT running. The fan speed can be determined from the TACHO option 2V AC { LOW MD HIGH TH2 TB2 COOL COM HAT t L M H COM TB5 TB HST F t MST DIP Switch Refer table for settings ALC INPUTS OUTPUT M H +V +V 0V Out Com L 0V In TH ALC 0-0V Limit Controller HC lectric Heat Contactor FAN Impeller Assembly 6 Diameter FAN2 Impeller Assembly 6 Diameter FROR Fan Run On Relay H Heater lement HST Auto High Temp. T/Stat MST Manual High Temp. T/Stat PR Power Relay SSR Solid State Relay temperzone Ltd 205 DO NOT SCAL - ASK 0-0V (DC) Signal from BMS or other controller Client Wiring 0V 0-0V TACHO FAN TACHO FAN2 Drawn: Apprvd: 0V 0-0V TACHO TACHO2 RV MODIFICATION DAT CN APVD F Swap Mains terminal sequence on motors; removed 0V DC available; N897 L.O.L. F New control loom,removed terminal joiners; PR was between SSR-TB2(COM), now L-Fans N897 L.O.L. TB F M.A.H. Date: 8/06/205 Model Fan full load current (FLA) lectric Heat current lectric Heat kw IMDL0Y IMDL60Y IMDL90Y IMDL0Y.A.8A.8A.2A 6.5A 8.7A.0A 7.A Title: Drawing No: Rev: IMDL 0Y-0Y.Heat c/w SSR F lectrical Wiring Schematic SHT OF

18 Filter Drop U2 rated filter media (standard) PRSSUR DROP (Pa) FINAL PRSSUR DROP 25 Pa INITIAL (Clean Filter) U2 (G2) FILTR FAC VLOCITY (m/s) Filter Area : IMDL 0Y 0. m 2 IMDL 60Y 0.9 m 2 IMDL 90Y 0.25 m 2 IMDL 0Y 0.5 m 2 Suggested Specification Furnish and install temperzone fan coil units as indicated on the schedule. Base Unit The base unit shall be fabricated of galvanised steel and insulated with closed cell foam on the discharge side of the fan. Motor Motors shall be electronically commutated (C) type with the option of stepped speed control or 0-00% variable capacity using a 0-0V dc signal supplied by BMS or sophisticated controller.* Coils Coils shall be comprised of die formed plate type aluminium fins mechanically bonded to high efficiency seamless inner rifled copper tubing. connections shall be male threaded. Cooling coils shall have a manual air vent. Drain Tray The plastic drain tray shall have an adjustment for inducing a positive drainage with the unit level. The tray shall project under the entire length and width of the coil including headers and return bends. The entire drain tray shall be removable to enable a thorough clean. Filters Filters shall be removable, mm thick, washable, rated U2, and mounted in a plastic frame. Filters may be slid out sideways when a return air duct is used. Insultation The base unit shall be insulated with closed cell foam to ensure no particles are introduced into the air steam. Insulation shall be foil faced and meet fire test standards AS 50. (989) and BS 76 parts 6 & 7. Noise Control Standard capacity units shall have a Sound Power Level (SWL) less than 55 db(a). Return air plenums shall be insulated with open cell foam for noise attenuation. lectric Heat lectric elements shall be fin-tube constructed of stainless steel and include both a manual and auto reset high temperature cutout switches (as required to meet AS/NZS ) and have variable capacity control via Solid State Relay (SSR). * The fan/motor may also be set to a single predetermined speed using a potentiometer. 8

19 Notes 9

20 Note: The manufacturer reserves the right to change specifications at any time without notice or obligation. Available from manufactured and distributed by: temperzone limited Head Office, Auckland : 8 Tidal Rd, Mangere, N.Z. Private Bag 90, Otahuhu, NW ZALAND. mail sales@temperzone.co.nz Website: temperzone australia pty ltd Head Office, Sydney : Carnagie Pl. PO Box 68, Delivery Centre, Blacktown, NSW 28, AUSTRALIA. mail sales@temperzone.com.au Website: 0/8 Pamphlet No. 697 temperzone limited 208

EC Motor Fan Coil Units. IMD-Y Series l/s

EC Motor Fan Coil Units. IMD-Y Series l/s EC Motor Fan Coil Units IMD-Y Series 45 235 l/s Temperzone s Fan Coil History Temperzone have been manufacturing chilled water fan coil units for more than 45 years. Company Profile Temperzone Limited

More information

EC Motor Fan Coil Units. IMDL-Y Series l/s

EC Motor Fan Coil Units. IMDL-Y Series l/s C Motor Fan Coil Units IMD-Y Series 7 l/s IMD-Y Fan Coil Units Company Profile Temperzone imited is a leading manufacturer and distributor of quality air conditioning and ventilation products throughout

More information

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil Ducted Three Phase Packaged Air Conditioner Technical Data, 0, 180 Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.0 kw 18.5 kw JUNE 5 , 0, 180 DUCTED PACKAGED ROOF TOP AIR CONDITIONERS

More information

Technical Data Ducted Three Phase Split System Air Conditioner

Technical Data Ducted Three Phase Split System Air Conditioner ENERGY EFFICIENT ISD / OSA 2 Technical Data Ducted Three Phase Split System Air Conditioner EXTRA LONG LIFE EPOXY COATED OUTDOOR COIL Nominal Cooling Capacity 26.5 kw (Total) JUNE 4 ISD / OSA 2 DUCTED

More information

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging Ducted Three Phase Packaged Air Conditioners Technical Data, 340, 370 Twin System Enables Staging Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 29.5 kw 34.0 kw 39.1 kw OCTOBER 2013

More information

Technical Data ISD 184KY / OSA 184RKTV. Ducted Split System Air Conditioner kw

Technical Data ISD 184KY / OSA 184RKTV. Ducted Split System Air Conditioner kw Ducted Split System Air Conditioner Technical Data ISD 184KY / OSA 184RKTV SEPARABLE INDOOR UNIT OPTION Optional SAT Controller High Efficiency EC Motor Extra Long Life Epoxy Coated Outdoor Coil Nominal

More information

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw Ducted Three Phase Packaged Air Conditioners Technical Data 96 RKTBG-P Plug Fan with High Efficiency EC Motor and High External Static Economiser Option TZT Controller & Digital Scroll Compressor for close

More information

Ducted Split System Air Conditioners Technical Data

Ducted Split System Air Conditioners Technical Data Technical Data ISDL 66, ISDL 87, ISDL 116 Cooling Capacity 6.7kW - 11.2kW Heating Capacity 6.2kW - 11.1kW Contents ISDL 66 116 KYX SERIES 3 General 3 Applications 4 Air Flow Selection 4 Features 4 Refrigerant

More information

Technical Data ISD 87KYX / OSA 87RKSH. Ducted Split System Air Conditioner. 8.5 kw

Technical Data ISD 87KYX / OSA 87RKSH. Ducted Split System Air Conditioner. 8.5 kw Ducted Split System Air Conditioner Technical Data ISD 87KYX / OSA 87RKSH SEPARABLE INDOOR UNIT Optional SAT-3 or TZT-100 Room Temperature Controller High Efficiency EC Motor Extra Long Life Epoxy Coated

More information

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw Underceiling/Console Split System Air Conditioners Technical Data ISU Series Featuring SAT- Controller & Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 13. kw 15 kw NOVEMBER 0 ISU SERIES

More information

Ducted Split System Air Conditioners Technical Data

Ducted Split System Air Conditioners Technical Data Technical Data ISD 294, ISD 324 Cooling Capacity 27.9kW - 34kW Heating Capacity 28.2kW -32.2kW Contents ISD 294, 324 KYX SERIES General 3 Applications 4 Air Flow Selection 4 Features 4 Refrigerant R410A

More information

Technical Data VPA 120, 160. Ducted Vertical Packaged Air Conditioner/Heat Pump kw 16.1 kw. Wide Ambient Capabilities

Technical Data VPA 120, 160. Ducted Vertical Packaged Air Conditioner/Heat Pump kw 16.1 kw. Wide Ambient Capabilities Ducted Vertical Packaged Air Conditioner/Heat Pump Technical Data, 1 Wide Ambient Capabilities Variable Capacity 2kW 12/16kW High Efficiency EC Plug Fan Versatile Configuration Including Controller & Digital

More information

Water Cooled Units HWP 370, 445. Cooling Capacity 36.6kW kW. Heating Capacity 34.9kW kW

Water Cooled Units HWP 370, 445. Cooling Capacity 36.6kW kW. Heating Capacity 34.9kW kW Water Cooled Units Technical Data HWP 370, 445 Cooling Capacity 36.6kW - 44.5kW Heating Capacity 34.9kW - 42.2kW Contents HWP 370, 445 General 3 Applications 4 Introduction 4 Features 5 Refrigerant 5 Efficient

More information

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil Ducted Packaged Roof Top Air Conditioners Product Review OPA-RK Series Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.6 kw 137 kw MEPS COMPLIANT INVERTER MODEL MODELS MARCH 2014

More information

Technical Data ACN Series. Modular Air Cooled Condensers. 68 kw 155 kw. Extra Long Life Epoxy Coated Outdoor Coil. Nominal Cooling Capacity

Technical Data ACN Series. Modular Air Cooled Condensers. 68 kw 155 kw. Extra Long Life Epoxy Coated Outdoor Coil. Nominal Cooling Capacity Modular Air Cooled Condensers Technical Data ACN Series Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 68 kw 155 kw MARCH 2010 ACN SERIES MODULAR AIR COOLED CONDENSERS General The ACN

More information

EHH SERIES DRAW THROUGH FAN COILS CFM

EHH SERIES DRAW THROUGH FAN COILS CFM EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE

More information

FAN COIL UNITS. The optimal solution for limited space

FAN COIL UNITS. The optimal solution for limited space FAN COIL UNITS The optimal solution for limited space CLEAN AIR SINCE 1963 Euroclima is a company with extensive international operations with four manufacturing facilities in Italy, Austria and India

More information

S Y D. HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance

S Y D. HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner Installation & Maintenance Fig. 1 Nomenclature Nomenclature e.g. H W P 3 5 C K Series Size Type S Y D GENERAL

More information

Item No. (Standard/Opposite Hand) /

Item No. (Standard/Opposite Hand) / SPCIICATIOS Model HWP 118RKTY Item o. (Standard/Opposite Hand) 510-118-001 / 510-118-011 Cooling capacity (net) to AS/ZS 3823 T1 11.9 kw Heating capacity H1 11.6 kw lectrical input - cooling 2.9 kw lectrical

More information

Cooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. Air Conditioning. Giving you complete control

Cooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. Air Conditioning. Giving you complete control Cooling Capacity 3.5kW - 101.6kW Heating Capacity 4.4kW - 98.6kW Water-Cooled Air Conditioning Giving you complete control More than just another air conditioning company. We re dedicated to pioneering

More information

OPTIONAL SPRING MTG HANGING CENTRES WATER CONN'S: TWO BSP MALE. 19 mm (3/4") ELECTRICAL CONDUIT HOLES ACCESS PANEL OUT (WATER) IN 485 MOUNTING

OPTIONAL SPRING MTG HANGING CENTRES WATER CONN'S: TWO BSP MALE. 19 mm (3/4) ELECTRICAL CONDUIT HOLES ACCESS PANEL OUT (WATER) IN 485 MOUNTING HWP 117 225 Ducted Water Cooled R410A Packaged Air Conditioner Dimensions (mm) Fig. 1 HWP 117 60 1210 SPRING MOUNTING CENTRES 690 (HEIGHT = 370) FILTER BOX PROJECTION Net Weight 105 kg Installation & Maintenance

More information

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit Fan Coil Unit 1 BOSCH Climate 000 Fan Coil Unit 2 Fan Coil Unit Introduction to Bosch Thermotechnology Bosch Thermotechnik GmbH is a leading supplier of resourceefficient heating products and hot water

More information

S D HWP 77, 96. Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance. Fig. 1 Nomenclature. Fig.

S D HWP 77, 96. Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance. Fig. 1 Nomenclature. Fig. HWP 77, 96 Ducted Water Cooled R410A Packaged Air Conditioner Installation & Maintenance Fig. 1 Nomenclature Nomenclature e.g. H W P 7 7 C K Series Size Type S D GENERAL HWP - A general designation which

More information

Efficient Cooling and Heating. Flexibility Is The Key

Efficient Cooling and Heating. Flexibility Is The Key Lynx Energy efficient fan coil unit Chilled water cooling & hot water heating Waterside control with variable air volume Commercially quiet with excellent acoustics Programmable communication control systems

More information

Panther Fan Coil Unit

Panther Fan Coil Unit Panther Fan Coil Unit Energy Efficient EC Motors 280mm Deep Chassis Horizontal Fan Coil Unit INTRODUCTION The Panther, manufactured by Dunham-Bush is an adaptable, easy to use fan coil unit, that performs

More information

YAH SERIES FAN COIL UNITS

YAH SERIES FAN COIL UNITS YAH Series Fan Coil Units Johnson Controls YORK YAH ceiling mounted cabinet fan coil units are terminal points of central air-conditioning systems. They are designed for fresh air units or to cool, heat,

More information

Aegean Range. A new range of fan coils for heating and cooling commercial applications

Aegean Range. A new range of fan coils for heating and cooling commercial applications egean Range new range of fan coils for heating and cooling commercial applications How Fan Coils work Fan Coils provide heating and cooling solutions for a wide range of applications. Fan Coil Unit (FCU)

More information

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make. All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing

More information

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax: Biddle Air Systems Limited St. Mary s Road, Nuneaton,Warwickshire CV AU. Tel: + 0 78 Fax: + 0 77 Email: sales@biddle-air.co.uk http://www.biddle-air.co.uk F.H. Biddle B.V. P. O. Box, NL-988 ZG Kootstertille,The

More information

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts Small Air Handling units SAM W i d e d u t y r a n g e 0.05m 3 /sec to 2.4m 3 /sec Powerful yet quiet Extensive options VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products

More information

Product Specifications. Vertical Floor Consoles By First Co.

Product Specifications. Vertical Floor Consoles By First Co. NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series

More information

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS EN DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS EBH EDS EBH EDS HIGH PRESSURE UNITS EBH high pressure ducted units and EDS Double Skin units, thanks to their high pressure fan decks, permit to satisfy

More information

Caice Attenuator Selector - Specifier Edition

Caice Attenuator Selector - Specifier Edition Fan Coil Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Prestige Attenuation Controls Package Plenum Heating Cooling Fan Coil Unit Acoustic Performance

More information

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS TC SERIES OPTIONS TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15,, 5 AIR COOLED PACKAGED WATER CHILLERS CONTENTS EQUIPMENT AND COMPONENT DETAILS PERFORMANCE AND TECHNICAL DATA SCHEMATIC FLOW & SYSTEM

More information

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS Homepage > Products > Fancoil units > Type PWX Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS Nominal sizes 60, 90, 120, 150, 180 and 205 Volume flow rate range

More information

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT 1. GENERAL INFORMATION 1.1 Applications page 2 1.2 Operation» 2 1.3 Performances» 2 1.4 Product range» 2 1.5 Selection software» 2 2. DIMENSIONS AND WEIGHTS» 3 3. COMPONENTS 3.1 Structure» 4 3.2 Coils»

More information

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T-TWIN is characterized by having no additional moisture

More information

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T is characterized by having no additional moisture added

More information

Caice Attenuator Selector - Specifier Edition

Caice Attenuator Selector - Specifier Edition Fan Coil Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Prestige Attenuation Controls Package Plenum Heating Cooling Fan Coil Unit Acoustic Performance

More information

INTRODUCTION Flexibility Is The Key Simple Access For Maintenance

INTRODUCTION Flexibility Is The Key Simple Access For Maintenance Cougar Energy efficient slimline 180mm fan coil unit Chilled water cooling & hot water heating Waterside control with variable air volume Commercially quiet with excellent acoustics Programmable communicating

More information

Specification Data. General:

Specification Data. General: Specification Data General: Zone Units (ACU s) will be draw through vertical type having double skin construction. All Zone Units will have all necessary components such as control valves and motors to

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

Packaged Air Conditioning Custom Build Solutions

Packaged Air Conditioning Custom Build Solutions Packaged Air Conditioning Custom Build Solutions Packaged Airconditioning Units - PA Range custom build customer driven Custom Build Customisation of Temperzone packaged units provides a high degree of

More information

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. Fresh air unit ALB ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. The ALB fresh air units from Helios provide comfortable room temperatures. Fresh outside air is

More information

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T-TWIN is characterized by having no additional moisture

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

Series CM. Cased fan convector Sill-Line 600mm high 7 sizes and 3 heating coil options 1-13kW output with LPHW C heating medium

Series CM. Cased fan convector Sill-Line 600mm high 7 sizes and 3 heating coil options 1-13kW output with LPHW C heating medium Series CM Cased fan convector Sill-Line 6mm high 7 sizes and 3 heating coil options 1-13kW output with LPHW 5-13 C heating medium CONTENTS IDENTIFICATION Identification Introduction 2 Authority 2 Description

More information

Catalog C: McQuay Horizontal Concealed Fan Coil Unit

Catalog C: McQuay Horizontal Concealed Fan Coil Unit Catalog C: 700-1 McQuay Horizontal Concealed Fan Coil Unit Model THC Sizes 200 Through 1200 CFM McQuay THC Horizontal Concealed Fan Coil Nomenclature F THC 1 H02 Fan-coil Type of Unit THC = Horizontal

More information

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units

More information

ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS

ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS CONTENTS Overview 2 Features & Benefits 3 Performance 4 Accent Pool Water to Water Heat Pumps Technical 5 Accent Hot Water Water to Water Heat Pumps Technical

More information

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM 0,7 kw 5,2 kw 1,6 kw 10,2 kw 130 m 3 /h 830 m 3 /h SLIM SLIMxx0 vertical with cabinet bottom vertical Available also with feet SLIMxx8 SLIMxx5 SLIMxx4 SLIMxx9

More information

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit MODEL: ACW200D ACW300D ACW400D ACW500D ACW600D ACW800D ACW900D ACW1000D ACW1200D ACW1400D ACWD-2006 ACWD_2006_Cover.indd 1 CEILING CONCEALED Chilled Water Fan Coils Unit 2006-5-25 17:24:07 Contents Main

More information

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-131.001 Page 1 Copyright 2017 Unico Inc. TABLE OF CONTENTS APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

LOW STATIC HYDRONIC DUCTED UNIT

LOW STATIC HYDRONIC DUCTED UNIT LOW STATIC HYDRONIC DUCTED UNIT PDWA-~AC SERIES PDWA(4R)-~-V-MEDC PDWA(4R)-~-V-MEEU PDWA(R)-~-V PDWA(R+1)-~-P Model cooling capacity( KW) at Medium Speed cooling capacity (KW) at Medium Speed cooling capacity

More information

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP EVH R-407C WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP Size Cooling Heating [kw] [kw] 7 2.0 1.9 11 2.6 2.5 15 3.9 3.3 5.2 5.5 25 7.3 6.7 31 8.9 8.4 41 10.7 9.8 REPLACE: BT02E009GB-01 The Versatemp

More information

iq Star LYRA II chilled beam cassette

iq Star LYRA II chilled beam cassette iq Star LYRA II chilled beam cassette Key features Ventilation Heating and cooling Compact chilled beam Adjustable induction Flow Pattern Control Integrated control In option: Demand Controlled Ventilation,

More information

VERTICAL FAN COIL UNITS

VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote

More information

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ) Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper

More information

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB TROX (U.K.) LTD CAXTON WAY GB-THETFORD NORFOLK IP24 3SQ TEL: 01842 754545 CONTENTS 1. INTRODUCTION 1. 1 DESCRIPTION 1.2 PACKAGING AND STORAGE 1.3 HANDLING

More information

Item No. (Standard/Opposite Hand) /

Item No. (Standard/Opposite Hand) / SPECIFICATIONS Model HWP 59RKS Item No. (Standard/Opposite Hand) 509-059-001 / 509-059-011 Cooling capacity (net) to AS/NZS 3823 T1 5.7 kw Heating capacity H1 5.4 kw Electrical input - cooling 1.6 kw Electrical

More information

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL PREPARED FOR: DATE: JOB NAME: WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL EQUIPMENT DETAILS ITEM TAG DESCRIPTION MODEL NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 EQUIPMENT

More information

Blower-YEFB-020-3R-1maxVel

Blower-YEFB-020-3R-1maxVel YEFB DUCTED UNIT GENERAL FEATURES Structure It is made of 1,0 mm thick galvanised steel. Despite this thickness, a special tool for production allowed to keep a good stiffness, in order to reduce the risk

More information

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron. Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 198 saw Advanced Australia Fair become

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron. Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 1984 saw Advanced Australia Fair become

More information

SKYPAK II Heating & Cooling Self Contained Packages

SKYPAK II Heating & Cooling Self Contained Packages SKYPAK II Heating & Cooling Self Contained Packages SKYPAK II gives you a complete airconditioning and heating system as an all-in-one package unit. Designed for conventional through-the-wall installation

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670 Bulletin AV-670 Series 670 Hood Monitor Specifications - Installation and Operating Instructions DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Phone: 219/879-8000 Fax: 219/872-9057

More information

Remote Air Cooled Condensers C2 Series

Remote Air Cooled Condensers C2 Series Remote Air Cooled Condensers C2 Series High Fan Speed Capacity 236kW Low Fan Speed Capacity 1740kW 180kW 1257kW Innovative Heat Transfer Solutions Issue date 04/14 APPLICATION BENEFITS / FEATURES HIGH

More information

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS 550.23-TG5Y (893) CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L2EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility.

More information

SeasonMaker ThinLine Fan-coil Units

SeasonMaker ThinLine Fan-coil Units Catalog C: 720-12 SeasonMaker ThinLine Fan-coil Units Type TSH & TSC Horizontal Design TSS, TPF, TSF & TSB Vertical Design C L I S T E D Ratings Certified by the Air Conditioning & Refrigeration Institute

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information

SeasonMaker ThinLine Fan-coil Units

SeasonMaker ThinLine Fan-coil Units Catalog C: 720-12 SeasonMaker ThinLine Fan-coil Units Type TSH & TSC Horizontal Design TSS, TPF, TSF & TSB Vertical Design C L I S T E D Ratings Certified by the Air Conditioning & Refrigeration Institute

More information

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts GTIP60 ISO GT Series, Inch Pounds 60 Hz GT010070 (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts Rev: 903 Rev 1 Revisions: 31103 Changed HZ dwg to field convertible 5902 changed Unit

More information

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A Publication No. WT-CSX-0616A Central Station Air Handling Units Complete HVAC Capability Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels

More information

Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position.

Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position. VMD Range Features & Benefits Performance range up to.4m /s Motor Insulation Class F Anodised aluminium pentapost frame Double skinned panels Compact direct drive units Electric heater battery Built-in

More information

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron. Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 1984 saw Advanced Australia Fair become

More information

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium

More information

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply. Halton CSW Swirl comfort unit for ceiling installation The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply. A combined cooling, heating, and supply-air unit for flush

More information

SINGLE DUCT TERMINAL UNITS

SINGLE DUCT TERMINAL UNITS Performance Data AHRI Certification and Performance Notes Model Series 3000 asic Unit AHRI Certification Rating Points VAV: Fiberglass Inlet Size Airflow cfm l/s Min. Inlet Ps w.g. Pa Discharge Sound Power

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

TOSHIBA AIR CONDITIONING

TOSHIBA AIR CONDITIONING Digital Inverter Standard Specification R32 Introduction The following specification describes the Toshiba Digital Inverter Heat Pump air conditioning system(s) to be installed at the below site: (ADD

More information

Caice Attenuator Selector - Specifier Edition

Caice Attenuator Selector - Specifier Edition Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Heating Cooling Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels

More information

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED

More information

Vertical Air Handler Unit

Vertical Air Handler Unit Bulletin 20-019 (September 2016) Vertical Air Handler Unit For cooling, the unit is designed for R-410A refrigerant (both A/C and Heat Pump) or a chilled water coil. For heating, the unit offers an optional

More information

Product Catalog. DCHC Horizontal Concealed Chilled Water Fan Coil with DCBL Motor Airflow: 180~2380 m 3 /h

Product Catalog. DCHC Horizontal Concealed Chilled Water Fan Coil with DCBL Motor Airflow: 180~2380 m 3 /h Product Catalog DCHC Horizontal Concealed Chilled Water Fan Coil with DCBL Motor Airflow: 180~2380 m 3 /h Table of Contents Product Features Product Benefits Group Controller.....................................................

More information

UniTrane Ductable Units D-line and B-Line

UniTrane Ductable Units D-line and B-Line UniTrane Ductable Units D-line and B-Line Discover the new UniTrane Ductable Units The ideal air-conditioning solutions for your building Air-conditioning plays an important role in the comfort level in

More information

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Compact, Self-Contained unit that offer low installation cost plus dependable performance. 0 Compact, Self-Contained unit that offer low installation cost plus dependable performance. From carrier s excellence in engineering come a new, compact of single package horizontal and vertical water

More information

Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160)

Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160) Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160) About Climate Wizard Climate Wizard s unique indirect evaporative heat exchange core provides hyper-efficient cooling of outside air.

More information

EnviroMagic. Low profile, ultra-high efficiency evaporative cooling for commercial and industrial applications

EnviroMagic. Low profile, ultra-high efficiency evaporative cooling for commercial and industrial applications EnviroMagic Low profile, ultra-high efficiency evaporative cooling for commercial and industrial applications World leading climate control solutions Seeley International is Australia s largest air conditioning

More information

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307 DESCRIPTION Technical Guide CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) This 20 ton evaporator blower is designed with two distinct modules to provide maximum application

More information

FCC Fan-Coil Units High-Performance, Vertical

FCC Fan-Coil Units High-Performance, Vertical FCC Fan-Coil s High-Performance, Vertical Model FCC construction features Piping and supply-duct connections are from top of unit, eliminating the need for side or back access Right or left-hand configurations

More information

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES Range 3.6 To 36.5 Tons 50Hz R22 TABLE OF CONTENT General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators

More information

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E INTRODUCTION DERV/ERV Introduction Dehumidification & Energy Recovery Ventilator DERV units

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION Ultra high performance Environmentally friendly with heat recovery solutions Optimised performance thanks to the control system Air flowrate: 1500 to 6000 m 3 /hr and a compact 400 mm profile Available

More information

Energy. The Energy ducted units have been designed. Heat Recovery Unit

Energy. The Energy ducted units have been designed. Heat Recovery Unit Energy Heat Recovery Unit The Energy ducted units have been designed to allow energy savings in the ventilation systems of public and private environments, such as bars, restaurants, offices, shops, etc.,

More information

QUALITAIR PACKAGED SYSTEMS & APPLIED CHILLED WATER PRODUCTS. Fan Coil Units. QCeiling Cassettes. Floor Standing Units

QUALITAIR PACKAGED SYSTEMS & APPLIED CHILLED WATER PRODUCTS. Fan Coil Units. QCeiling Cassettes. Floor Standing Units AIR CONDITIONING An air conditioned environment is increasingly expected in retail, commercial and industrial premises. Whilst there will always be a demand for custom built air conditioning the standard

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) (994) SPLIT-SYSTEM EVAPORATOR BLOWER K5EU090 and K4EU120 50 Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX coil

More information