1 INDUCED DRAFT HIGHBOY AND COUNTERFLOW/HORIZONTAL GAS FURNACE USERS INFORMATION MANUAL MODELS FOR USE WITH NATURAL GAS MHA-50N, MHA-75N, MHA-100N, MHA-125N, MDA-50N, MDA-75N, MDA-100N, MDA-125N FOR USE WITH L.P. GAS (PROPANE) MHA-50P, MHA-75P, MHA-100P, MHA-125P, MDA-50P, MDA-75P, MDA-100P, MDA-125P : IF YOU DO NOT FOLLOW THE SAFETY PRECAUTIONS BELOW AND IN THIS MANUAL, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. WHAT TO DO IF YOU SMELL GAS: DO NOT TRY TO LIGHT ANY APPLIANCE. DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY PHONE IN YOUR BUILDING. LEAVE THE BUILDING IMMEDIATELY. IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR S PHONE. FOLLOW THE GAS SUPPLIER S INSTRUCTIONS. IF YOU CANNOT REACH YOUR GAS SUPPLIER; CALL THE FIRE DEPARTMENT. INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER. (REFERRED TO IN THESE INSTRUCTIONS AS A QUALIFIED HEATING CONTRACTOR). PLEASE READ THESE INSTRUCTIONS PRIOR TO INITIAL FIRING, OPERATING THE FURNACE, AND BEFORE PERFORMING ANY MAINTENANCE. THESE INSTRUCTIONS MUST BE LEFT WITH THE HOMEOWNER AND SHOULD BE RETAINED FOR FUTURE REFERENCE BY THE HOMEOWNER/USER. THERMO PRODUCTS, LLC. BOX 217 MG-994 NORTH JUDSON, IN ECN 4199-MI 05/00 PHONE: (219) MADE IN USA
2 INDEX SECTION PAGE I. SAFETY INFORMATION 1 II. GENERAL INSTRUCTIONS 5 III. FURNACE OPERATION 8 A. WARNINGS AND OPERATION 8 B. OPERATING INSTRUCTIONS 9 C. SHUTDOWN PROCEDURE 10 IV. HOMEOWNER/USER MAINTENANCE INSTRUCTIONS 10 (ROUTINE MAINTENANCE) A. ANNUAL INSPECTION 10 B. FILTER MAINTENANCE PROCEDURE 10 C. VISUAL INSPECTION PROCEDURE 12
3 I. SAFETY INFORMATION This page and the following page contain reproductions of the various instruction and warning labels placed on the Thermo Pride Sectional Gas Furnaces. Please read and comply with the contents of these labels. 1
4 2
5 The following warnings and cautions are found throughout the Thermo Pride Sectional Gas Furnace Manual. Please read and comply with the statements below. : IF YOU DO NOT FOLLOW THE SAFETY PRECAUTIONS BELOW AND IN THIS MANUAL, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. Property damage, personal injury or loss of life could result from repair or service of this furnace by anyone other than a qualified heating contractor. Only the routine maintenance described in this manual may be performed by the user. This furnace operates by burning gas inside your home. This creates the possibility of fire or an explosion which could result in serious injury or death. You must read and follow all of these safety precautions to help ensure safe operation of your furnace and to prevent a life-threatening fire or explosion from ever occurring. To avoid injury from moving parts and to avoid electrical shock, shut off power to the furnace before removing the blower compartment door. : Do not block or obstruct air openings on the furnace or air openings communicating with the area in which the furnace is installed. : If you suspect there is a problem with the furnace, its venting system or any other related problem, immediately contact a qualified service agency. : In the event your furnace fails to operate, do not attempt to put the furnace into operation. Contact a qualified heating contractor to service the furnace. : The furnace must have an adequate supply of fresh and clean air for safe combustion. If chemical vapors get into the furnace, hazardous fumes may result. Pay attention to the safety rules below to prevent you and your family from being injured by these hazardous chemical vapors. : If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. : Homeowners attempting service other than covered as homeowner/user maintenance may cause conditions which could result in personal injury or property damage. 3
6 : Shut off the power to the furnace before removing blower compartment door to avoid injury from moving parts. : This furnace is not to be used for temporary heating of buildings or structures under construction. : CALL A QUALIFIED HEATING CONTRACTOR TO REPORT SUSPECTED DEFICIENCIES. (DO NOT ATTEMPT TO MAKE REPAIRS YOURSELF!) : Failure to keep the condensate trap filled may allow flue gases to enter the living space. NOTE: This warning only applies to sidewall venting. : Because of the potential of odorant fade, a gas leak may not be detected by smell. If this furnace is installed below grade, contact your gas supplier for a gas detector. 4
7 II. GENERAL INSTRUCTIONS 1. Property damage, personal injury or loss of life could result from repair or service of this furnace by anyone other than a qualified heating contractor. Only the routine maintenance described in this manual may be performed by the user. 2. This furnace operates by burning gas inside your home. This creates the possibility of fire or an explosion which could result in serious injury or death. You must read and follow all of these safety precautions to help ensure safe operation of your furnace and to prevent a life-threatening fire or explosion from ever occurring. 3. POSSIBILITY OF BURNS, CUTS OR ELECTRICAL INJURY To avoid injury from moving parts and to avoid electrical shock, shut off power to the furnace before removing the blower compartment door. Do not perform any maintenance on the furnace while it is operating. Read and follow the maintenance instructions provided with this furnace before beginning any maintenance work. Care must be taken whenever the doors are removed from this appliance. This may expose sharp edges or points which could cause cuts, hot surfaces which could cause burns, and electrical circuits which could cause shocks. Instruct children on the safety hazards associated with furnaces. Keep children away from the furnace at all times. 4. Keep furnace free and clear of combustible materials, gasoline and other flammable liquids and vapors. Do not store combustible materials near the furnace. The furnace must have adequate clearances from all combustible materials such as clothing, paper, cardboard, wood, cleaning materials or flammable liquids to prevent them from igniting. 5. For safe and proper operation, the furnace needs air for combustion and ventilation. : Do not block or obstruct air openings on the furnace or air openings communicating with the area in which the furnace is installed. Do not operate this furnace without provisions for an adequate combustion air supply. Keep all insulation materials at least twelve inches away from all burner openings. Do not block or cover any openings which supply combustion and ventilation air to the furnace. Follow all instructions in this manual for providing ample combustion and ventilation air. 5
8 IMPORTANT: For sidewall vented furnaces, do not allow the outside vent terminal to be blocked or obstructed by vegetation, ice, snow or any other materials. 6. Should this unit be installed in an attic or other insulated area or if the area is insulated after the furnace is installed, the furnace area must be examined and kept free and clear of the insulating material and any fibers that may have come loose. Remember some insulating materials are combustible. 7. No attempt should be made to restart the unit in the event that the gas to the main burner has been shut off. Contact a qualified heating contractor before restarting the furnace. 8. The furnace should be inspected annually by a qualified heating contractor. 9. Do not use this furnace if any part has been under water. Immediately call a qualified heating contractor to inspect the furnace and to replace any part of the control system and any gas control which has been under water. 10. Should overheating occur or the gas supply fail to shut off, shut off the manual gas valve to the furnace before shutting off the electrical supply. : If you suspect there is a problem with the furnace, its venting system or any other related problem, immediately contact a qualified service agency. 11. Check carefully for gas before lighting a furnace. Some gas is heavier than air and may settle near the ground. Search for gas odor by sniffing at ground level in the area of the furnace. 12. Figure 1 illustrates a typical furnace installation and the typical position of the components referenced in these instructions. 13. Your furnace should be described by the model number and serial number when contacting a qualified heating contractor. This important information is located on the rating plate behind the front door. (See Figure 1). 14. This furnace is equipped with a safety feature which will not allow the furnace to be operated if the outlet vent to the appliance is blocked. : In the event your furnace fails to operate, do not attempt to put the furnace into operation. Contact a qualified heating contractor to service the furnace. 6
9 Figure 1. 7
10 15. POSSIBLE HAZARD FROM CHEMICAL VAPORS : The furnace must have an adequate supply of fresh and clean air for safe combustion. If chemical vapors get into the furnace, hazardous fumes may result. Pay attention to the safety rules below to prevent you and your family from being injured by these hazardous chemical vapors. Aerosol spray propellants and volatile compounds (cleaners, chlorine-based chemicals, refrigerants, and others) may be highly flammable. They may also create corrosive compounds such as hydrochloric acid when exposed to the furnace combustion products. These fumes are hazardous and can also cause the furnace to fail. Typical locations and chemicals with potentially corrosive vapors are beauty and barber shops, photo processing labs, cleaning establishments, laundries and dry cleaners, liquid and powdered bleaches, swimming pool chemicals, cleaning solvents, refrigerator and air conditioning refrigerants, calcium and sodium chloride, waxes and process chemicals. All of the above materials are corrosive at very low concentration levels with little or no odor to reveal their presence. Do not store these chemicals near the furnace. If operation in this type of area is necessary, a qualified heating contractor must be contacted to install a means of providing uncontaminated combustion air from outside sources. III. FURNACE OPERATION A. WARNINGS BEFORE OPERATION FOR YOUR SAFETY, READ BEFORE OPERATING : If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. B. BEFORE OPERATING - smell all around the appliance area for gas. Be sure to smell next to the floor because some gases are heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS * Do not try to light any appliance. * Do not touch any electric switch; do not use any phone in your building. * Immediately call your gas supplier from your neighbor's phone. * Follow the gas suppliers instructions. * If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified heating contractor. Force or attempted repair may result in a fire or explosion. 8
11 B. OPERATING INSTRUCTIONS TO START THE FURNACE: 1. Please read the safety information in this book before operating furnace. 2. Set the thermostat to the lowest setting. 3. Turn off all electric power to the appliance. 4. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 5. Remove front door. 6. Turn the knob on combination gas valve to the full off position. Figure Wait five (5) minutes to clear out any gas. Then smell for gas including near the floor. If you then smell gas, STOP! Follow Step A in the previous safety information. If you don't smell gas, go to the next step. 8. Turn the knob on combination gas valve to the ON position. 9. Replace front door. 10. Turn on electric power to the appliance. 11. Set thermostat to desired setting. 12. If the appliance will not operate, follow the instructions "To Turn Off Gas To Appliance" and call a qualified heating contractor or gas supplier. 9
12 C. SHUTDOWN PROCEDURE TO TURN OFF GAS TO FURNACE 1. Set the thermostat to lowest setting. 2. Turn off the electric power to the appliance if service is to be performed. 3. Remove front door. 4. Turn the knob on the combination valve to the full OFF position. 5. Replace front door. IV. HOMEOWNER/USER MAINTENANCE INSTRUCTIONS (ROUTINE MAINTENANCE) The following maintenance procedures should be performed by the homeowner/user during the heating season. : Homeowners attempting service other than covered as homeowner/user maintenance may cause conditions which could result in personal injury or property damage. To avoid injury from moving parts and to avoid electrical shock, shut off power to the furnace before removing the blower compartment door. A. ANNUAL INSPECTION The homeowner must have this furnace professionally inspected at the beginning of each heating season by a qualified heating contractor to ensure proper operation. Instructions for the dealer maintenance needed for this furnace can be found in the "Installation and Service Manual." NOTICE: This furnace has been shipped from the factory with a permanently lubricated circulating air blower motor. Any maintenance to this blower motor is to be performed only by a qualified service agency. B. FILTER MAINTENANCE PROCEDURE The return air filter provided with this unit is a re-usable type filter. This filter should be inspected monthly and when dirty, cleaned or replaced if necessary, to assure proper furnace operation. Follow the cleaning, removal and replacement procedure below. 10
13 NOTE: If the furnace is installed in a dusty environment, dust levels must be much higher than normal. The filter must be inspected daily and cleaned as needed until dusty conditions have been eliminated. : This furnace is not to be used for temporary heating of buildings or structures under construction. MHA FURNACE Figure 3. The filter rack or drop chute will be located between the return air plenum and the return air opening of the furnace (See Figure 3). Slide dirty filter out of the filter rack. Clean the filter by vacuuming, rinsing with tap water, hosing or dipping in an ordinary detergent solution. Replace the completely dry filter in the rack. The mesh side of the filter must be installed towards the furnace after cleaning. MDA FURNACE TURN OFF POWER TO FURNACE. The filter rack will be located on top of the furnace inside the return air duct using either a V-rack or a drop chute similar to one shown for the MHA in Figure 3. To change filter with a front load type drop chute, follow the instructions for a MHA. To change filters using the V-rack, remove the furnace front door and remove the filters through the blower opening (or in the event access slots are provided in the plenum, pull the filters directly out through these slots). Clean filters by vacuuming, tap water rinsing, hosing or dipping in an ordinary detergent solution. After cleaning, replace completely dry filter, mesh side down on the filter rack on the top of the furnace. Replace front door. Turn on power to furnace. 11
14 FILTER REPLACEMENT See Table 1 for minimum heating filter areas required for the different types of filters available should the filter used require replacement. If the unit is equipped with cooling, contact your installer or a qualified service person to determine the minimum filter area required for the different filter types and your cooling system. MINIMUM FILTER AREA REQUIRED (LENGTH X WIDTH, SQ. IN.) FILTER TYPE *THERMO PRODUCTS SUPPLIED PERMANENT FILTER STANDARD PERMANENT FILTER DISPOSABLE TYPE FILTER MAXIMUM RATE AIR VELOCITY MHA,MDA50 FURNACE MODEL MHA,MDA75 MHA,MDA100 MHA,MDA FT./MIN. 172 IN IN IN IN FT./MIN. 208 IN IN IN IN FT./MIN. 344 IN IN IN IN. 2 TABLE 1 * The Thermo Products supplied filter can be cut to size to fit other filter retention systems as long as the minimum size requirement is met. NOTICE: Any internal stiffeners used in the filter must not be removed, although they can be cut to size as needed. C. VISUAL INSPECTION PROCEDURE It is recommended that the homeowner/user conduct the following periodic visual inspection of the furnace at the start of the heating season and monthly during the heating season. : CALL A QUALIFIED HEATING CONTRACTOR TO REPORT SUSPECTED DEFICIENCIES. (DO NOT ATTEMPT TO MAKE REPAIRS YOURSELF!) 1. Turn off power to furnace. 2. Flue Pipe Connection & Chimney: Visually check flue pipe and chimney for tightness, blockage and corrosion. If fittings are loose or if blockage or corrosion is suspected to be a problem, contact a qualified heating contractor. Make sure horizontal runs of the flue have an upward slope away from furnace of 1/4" per foot minimum and are physically sound without holes, cracks or signs of corrosion. There should be no sign of moisture or vent gas leakage at any vent connection. 12
15 ADDITIONAL REQUIREMENTS OF FURNACES VENTED THROUGH THE SIDE OF THE HOUSE WITH NO CHIMNEY. a. Such horizontally vented furnaces should also be inspected to make sure that all vent joints are sealed and that the outside vent terminal is clear and free of obstruction by ice, snow or debris. Any obstruction of the terminal should be carefully removed without damaging the vent terminal. If ice has formed on the terminal itself, it should be removed using a blow dryer. b. The sidewall venting kit (SWGII Power Venter) manufacturer s instructions to be supplied by Field Controls. Use information must be supplied by the installer then read and understood by the user. 3. Return Air Duct Connection: Check to see if it is: (1). physically sound (2). sealed to the furnace casing and (3). terminates outside the space containing the furnace. 4. Make sure the furnace is sealed to the base (if applicable) without sagging, cracks or gaps. Make sure there are no signs of deterioration of the furnace or base. 5. Remove vestibule door and inspect control compartment for signs of damaged or unusually worn wiring, condensation, sooting or other damage or deterioration. 6. Restore power to the furnace. Follow the operating instructions to light furnace. 7. Make sure the burner flames are in good adjustment (See Figure 5). Burner flames should not impinge or fire against the side of the tube opening. NOTICE: It is not unusual to have orangish flames visible in the tube for LP gas. Figure 5. : Call a qualified heating contractor to report suspected deficiencies (do not attempt to make repairs yourself!) 13
OWNER S MANUAL HIGH EFFICIENCY VARIABLE SPEED GAS-FIRED FURNACES
OWNER S MANUAL HIGH EFFICIENCY VARIABLE SPEED GAS-FIRED FURNACES TABLE OF CONTENTS HOW YOUR GAS FURNACE WORKS...................... 2 KEEP THE FURNACE AREA CLEAR....................... 2 SFOR YOUR SAFETY,
More informationUSER S INFORMATION MANUAL
USER S INFORMATION MANUAL UPFLOW & DOWNFLOW/HORIZONTAL CONDENSING GAS FURNACES SAFETY Recognize this symbol as an indication of Important Safety Information If not installed, operated and maintained in
More informationUSER S INFORMATION MANUAL
USER S INFORMATION MANUAL UPFLOW, DOWNFLOW, UPFLOW/HORIZONTAL & HORIZONTAL ONLY INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this
More informationUSER S INFORMATION MANUAL
USER S INFORMATION MANUAL UPFLOW/HORIZONTAL & DOWNFLOW TWO STAGE INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this manual is not
More informationEL296UHV SERIES GAS FURNACE WARNING WARNING
2011 Lennox Industries Inc. Dallas, Texas, USA 506769 01 08/2012 Supersedes 10/2011 EL296UHV SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property
More informationEL195UHE SERIES GAS FURNACE WARNING WARNING
2012 Lennox Industries Inc. Dallas, Texas, USA 506737-01 12/2012 Supersedes 06/2011 EL195UHE SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property
More informationP.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces
P.O. Box 799900, Dallas, TX 75379-9900 USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in manuals,
More informationUSER S INFORMATION MANUAL
2017 Lennox Industries Inc. Dallas, Texas, USA 506737-01 04/2017 Supersedes 03/2017 USER S INFORMATION MANUAL EL195UHE SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance
More informationSLP98UH SERIES VARIABLE CAPACITY GAS FURNACE WARNING WARNING
2015 Lennox Industries Inc. Dallas, Texas, USA 506443-01 01/2015 Supersedes 08/2012 SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can
More informationML180UH SERIES GAS FURNACE WARNING WARNING
2017 Lennox Industries Inc. Dallas, Texas, USA 506525-01 04/2017 Supersedes 10/2015 ML180UH SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property damage,
More informationPackaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit
Packaged Gas/Electric Units Owner s Guide to Operating and Maintaining Your Gas/Electric Unit ELECTRICAL SHOCK HAZARD. FIRE OR EXPLOSION HAZARD Disconnect power at fuse box or service panel before performing
More informationEL195DFE SERIES GAS FURNACE WARNING
2011 Lennox Industries Inc. Dallas, Texas, USA 506739 01 06/2011 EL195DFE SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could result in serious injury,
More informationUSER S INFORMATION MANUAL (2,4)SG13B
USER S INFORMATION MANUAL (2,4)SG13B Series Gas Heating/Electric Cooling Package Unit Congratulations......your outdoor heating/cooling package unit is a valuable piece of equipment, designed and manufactured
More informationG61MPV SERIES GAS FURNACE WARNING
2003 Lennox Industries Inc. Dallas, Texas, USA 504,809M 03/2009 Supersedes 06/2003 G61MPV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could result
More informationWARNING FIRE OR EXPLOSION HAZARD.
2017 Lennox Industries Inc. Dallas, Texas, USA 506897-01 04/2017 Supersedes 10/2015 EL280DF SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property damage,
More informationEL195UH SERIES GAS FURNACE WARNING
2010 Lennox Industries Inc. Dallas, Texas, USA 506597 01 11/2010 EL195UH SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could result in serious injury,
More informationOIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE
58CLA OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. WELCOME TO A NEW GENERATION
More informationAqua Balance. User s Information Manual. WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water
Aqua Balance WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water User s Information Manual * Low Lead Content If the information in this manual is not followed exactly, a fire
More informationNOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.
c_::_':_-_:_ r'" _" "_1 WARNING: If the information in this manual is not followed exactly, a fire or explosion may Iresult causing property damage, personal injury or [loss of life. m m m Do not store
More informationWARNING FIRE OR EXPLOSION HAZARD.
2017 Lennox Industries Inc. Dallas, Texas, USA 506698-01 04/2017 Supersedes 10/2015 SL280DFV SERIES GAS FURNACE Improper installation, adjustment, alteration, service or maintenance can cause property
More informationBosch 80% AFUE Gas Furnace BGS80 Model
Bosch 80% AFUE Gas Furnace BGS80 Model 4-Way Multipoise Category I Fan-Assisted Furnace User's Information Manual 3124627 2 Bosch 80% AFUE Gas Furnace User's Information Manual Data subject to change 06.2018
More informationModel BW9 Gas-Fired Direct Vent Condensing Water Boiler
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable
More informationUSER S INFORMATION MANUAL SLP98UHV SERIES
2017 Lennox Industries Inc. Dallas, Texas, USA 506443-01 04/2017 Supersedes 10/2015 USER S INFORMATION MANUAL SLP98UHV SERIES VARIABLE CAPACITY GAS FURNACE Improper installation, adjustment, alteration,
More informationMANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS:
U S E R S I N F O R M AT I O N MANUAL 2017 Lennox Industries Inc. Dallas, Texas, USA SL280UHNV SERIES 507650-01 10/2017 Improper installation, adjustment, alteration, service or maintenance can cause property
More informationThis document was created with FrameMaker 4.0.4
This document was created with FrameMaker.0. WELCOME TO TODAY S GENERATION OF COMFORT Congratulations! Your new, higher efficiency gas furnace is a sound investment which will reward you and your family
More informationRETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE :$51,1*
352'8&7 /,7(5$785(. /HQQR[,QGXVWULHV,QF 'DOODV 7H[DV 503,877M 02/99 Supersedes 9/98 G24M SERIES 50HZ GAS FURNACE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Litho USA :$51,1* If the information in this
More informationUser s Information Manual Lynx Direct-Vent Sealed Combustion Condensing Boiler Model LX-90, LX-120, LX-150
Residential Gas fired Hot Water Boilers User s Information Manual Lynx Direct-Vent Sealed Combustion Condensing Boiler Model LX-90, LX-120, LX-150 FOR YOUR SAFETY: Before operating this boiler, READ this
More informationResidential Gas Hybrid Water Heater
Residential Gas Hybrid Water Heater USER S INFORMATION MANUAL WGRGH20NG75F / WGRGH20NG76F / WGRGH20NG100F WGRGHNG75F / WGRGHNG76F / WGRGHNG100F Models* *A suffix of LP denotes propane gas NOTICE: Westinghouse
More informationElite. User s Information Manual. Elite and Elite VWH* All Models
Elite User s Information Manual Elite and Elite VWH* All Models Heat Exchanger Bears the ASME H Stamp IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT, CAUSING
More informationUSER'S MANUAL PGE Single Package Rooftop
USER'S MANUAL PGE Single Package Rooftop Gas Heating/Electric Cooling Units Sizes 036-150 3 to 12-1/2 Tons NOTE TO INSTALLER: This manual should be left with the equipment owner. WARNING: If the information
More informationGAS FURNACE. User's Information Manual for the operation and maintenance of model GB1AAV or GB3AAV Gas Furnace
GAS URNACE User's Information Manual for the operation and maintenance of model GB1AAV or GB3AAV Gas urnace NOTE: This manual must be left with the equipment user. MODEL GB1AAV UPLOW URNACE WARNING: If
More informationMC Series Gas-Fired Heating Appliance
MC Series Gas-Fired Heating Appliance USER S INFORMATION MANUAL MC Series Models MC50 / MC80 MC99 / MC120 NOTICE: HTP reserves the right to make product changes or updates without notice and will not be
More informationUser s Information Manual
User s Information Manual CONDENSING GAS BOILER 220/299/300/399 If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal injury or loss
More informationUser s Information Manual
User s Information Manual Gas-Fired Water Boilers With or without Aqua Logic (CWH) Now available Matching High Performance Companion Water Heater (Unit sold separately) If the information in this manual
More informationUSER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater
USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater Contents Section Page Major Components... 2 1 About Our Manual... 2 2 Refractory Handling...
More informationUSER S INFORMATION MANUAL
2005 Lennox Industries Inc. Dallas, Texas, USA USER S INFORMATION MANUAL 13GCSX SERIES UNITS GAS PACKAGED UNITS (2 5 TONS) Armstrong # 38152A068 505,058M 05/09 Supersedes 08/05 Table of Contents Litho
More informationUSER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY...................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS.......................... 2 INTERMITTENT IGNITION DEVICE..........
More informationNOTE TO INSTALLER: This manual must be left with the equipment user. Model 480BAV Upflow and 481BAV Downflow/Horizontal
NOTE TO INSTALLER: This manual must be left with the equipment user. Model 0BAV Upflow and BAV Downflow/Horizontal USER S INORMATION MANUAL OR THE OPERATION AND MAINTENANCE O YOUR NEW GAS-IRED URNACE WARNING:
More informationREAD ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING
2005 Lennox Industries Inc. Dallas, Texas, USA 505,058M (38152A068) 08/05 Supersedes 06/05 13GCSX Series Units Improper installation, adjustment, alteration, service or maintenance can cause property damage,
More informationTankless Water Heater
Tankless Water Heater USER S INFORMATION MANUAL Models WGRT**150 / WGRT**199 / WGRTC**199 **A suffix of LP denotes propane gas **A suffix of NG denotes natural gas NOTICE: Westinghouse reserves the right
More informationUser s Information Manual
User s Information Manual Gas-Fired Storage Water Heater, Tankless Water Heater, Heating Appliance, and Combination Appliance Models IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR
More informationUniversal Fire Tube Boiler Wall Mount Models
Universal Fire Tube Boiler Wall Mount Models USER S INFORMATION MANUAL Models WBRU**80W / 100W / 120W / 140W / 175W / 199W **NG denotes Natural Gas Model, LP Denotes Propane Model Heat Exchanger Bears
More informationModel RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL
Model RGAC/SGAC Self Contained Cooling/Gas Heat Supersedes: 145.24-O1 (708) Units Form 145.24-O1 (908) MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL CATEGORY III GAS HEATING/ELECTRIC
More informationUSER S INFORMATION MANUAL
USER S INFORMATION MANUAL THESE INSTRUCTIONS APPLY TO THE MODEL GTM SERIES GAS- FIRED WARM AIR FURNACE. This symbol indicates important Safety Related Information FIRE OR EXPLOSION HAZARD Failure to follow
More informationMODELS 373LAV, 376CAV DOWNFLOW/HORIZONTAL and 383KAV, 395CAV UPFLOW GAS FURNACE
USER S INORMATION MANUAL USER S INORMATION MANUAL MODELS LAV, CAV DOWNLOW/HORIZONTAL and KAV, CAV UPLOW GAS URNACE NOTE TO INSTALLER: This manual must be left with the equipment user. Upflow WARNING: If
More informationUSER S INFORMATION MANUAL
USER S INFORMATION MANUAL FOR YOUR COMBINATION GAS HEATING/ELECTRIC COOLING AIR CONDITIONING UNIT DO NOT DESTROY. PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCE BY A SERVICEMAN OR
More informationUSER S INFORMATION MANUAL
USER S INFORMATION MANUAL HOT WATER HEATING BOILERS DOMESTIC WATER HEATERS 150,000-300,000 Btu/hr MODELS EB-EWU-02 IMPORTANT INSTALLER - AFFIX INSTALLATION MANUAL ADJACENT TO THE BOILER CONSUMER - RETAIN
More informationHOME OWNER S INFORMATION Induced Combustion Gas Furnace
HOME OWNER S INFORMATION Induced Combustion Gas Furnace NOTE TO INSTALLER: This manual must be left with the equipment user. USER: Please read all instructions in the manual and retain all manuals for
More informationUser s Information Manual
Gas-fired Water boiler Series 2 NOTICE: Series 1/Series 2 identification Read the boiler rating plate to determine the series number. The rating plate is located on the right side of the boiler. User s
More informationZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING
See unit nameplate for manufacturer and address. 507258-04 7/2018 Supersedes 10/2017 ZG 036, 048, 060, 072, 074 (3, 4, 5 and 6 Tons) ZG 092, 102, 120, 150 (7-1/2, 8-1/2, 10 and 12 Tons) ROOFTOP UNITS ZG
More informationUSER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS.......................... 2 INTERMITTENT IGNITION DEVICE...........
More informationUser s Information Manual
TM User s Information Manual Commercial Condensing Gas-fired water boilers If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal injury
More informationUser s Information Manual
User s Information Manual Series 3 Models 550 and 750 MBH Commercial Condensing Gas-fired water boilers If the information in this manual is not followed exactly, a fire or explosion may result, causing
More informationPackaged Gas/Electric
Packaged Gas/Electric Units Owner's Guide to Operating and Maintaining Your Gas/Electric Unit ELECTRICAL SHOCK HAZARD. FIRE OR EXPLOSION HAZARD Failure to follow this warning can result in Disconnect power
More informationUser s Information Manual
User s Information Manual Series 2 Models 1000-2000 MBH Commercial Condensing Gas-fired water boilers If the information in this manual is not followed exactly, a fire or explosion may result, causing
More informationGas Fired Residential Combi Boiler Floor and Wall Mount Models
Gas Fired Residential Combi Boiler Floor and Wall Mount Models USER S INFORMATION MANUAL Models WBRC**140W WBRC**199W WBRC**140F WBRC**199F ** NG Refers to Natural Gas Operation LP Refers to Propane Gas
More informationOwner s Manual. ama PG9MXA TWO --- STAGE CONDENSING GAS FURNACE ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.
Owner s Manual PG9MXA TWO --- STAGE CONDENSING GAS FURNACE NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. USER: PLEASE READ ALL INSTRUCTIONS IN THE MANUAL AND RETAIN ALL MANUALS FOR
More informationOwner's Manual. Induced Combustion Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.
Induced Combustion Gas Furnace Owner's Manual NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. USER: PLEASE READ ALL INSTRUCTIONS IN THE MANUAL AND RETAIN ALL MANUALS FOR FUTURE REFERENCE.
More informationGOLD. User s Information Manual. Water Boiler Series 4
GV Water Boiler Series 4 User s Information Manual If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal injury or loss of life. Do
More informationUser's Infomation Manual
User's Infomation Manual 574A GAS HEATING/ELECTRIC COOLING Cancels: OM01-69 OM10-28 02-07 NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Note to Installer:
More informationGAS BOILERS USER'S INFORMATION MANUAL SG-135-E TO SG-495-E AAA-480 TO AAA-3000
USER'S INFORMATION MANUAL GAS BOILERS FOR MODELS: MG-50-E TO MG-150-E SG-135-E TO SG-495-E AAA-480 TO AAA-3000 WARNING: If the information in this manual is not followed exactly, a fire or explosion may
More informationGOLD CGt. User s Information Manual. Natural gas-fired water boiler with tankless heater
TM GOLD CGt Natural gas-fired water boiler with tankless heater User s Information Manual If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage,
More informationFig. 1 - Unit PGD4, PGS4, WPG4
OWNER S MANUAL 14 SEER Single -Package Air Conditioner and Gas Furnace System with R -410A Refrigerant Single Phase 2 to 5 Nominal Tons Three Phase 3 to 5 Nominal Tons PGD4andPGS4SeriesE,WPG4SeriesB Fig.
More informationOwner s Manual. Induced Combustion Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.
Induced Combustion Gas Furnace NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. Owner s Manual CERTIFIED USER: Please read all instructions in the manual and retain all manuals for
More informationIf the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
prestige User s Information Manual If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY Do
More informationKG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING
See unit nameplate for manufacturer and address. 507350-03 3/2016 Supersedes 9/2015 KG 024, 030, 036, 048, 060, 072, 074, 090 (2, 2-1/2, 3, 4, 5, 6 and 7-1/2 Tons) KG 092, 102, 120, 150 (7-1/2, 8 1/2,
More informationUSER'S INFORMATION MANUAL
USER'S INFORMATION MANUAL SERIES DV GAS FIRED HOT WATER HEATING BOILER WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal
More informationOwner s Information Manual
48ES---A and 48VL---A Comfort and Performance 13 and 14 SEER Single Packaged Air Conditioner and Gas Furnace System With Puron (R---410A) Refrigerant Single and Three Phase 2---5 Nominal Tons (Sizes 24---60)
More informationUSER'S INFORMATION MANUAL
USER'S INFORMATION MANUAL CAST IRON GAS FIRED WATER HEATING BOILERS WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal
More informationHOME OWNER S INFORMATION High Efficiency Condensing Gas Furnace
HOME OWNER S INFORMATION High Efficiency Condensing Gas Furnace NOTE TO INSTALLER: This manual must be left with the equipment user. USER: Please read all instructions in the manual and retain all manuals
More informationOil Furnace USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE
Oil Furnace USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE MODEL PO8LAA LOW-BOY NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. MODEL PO8UAA
More informationOwner s Manual PG9MAB ! WARNING. Condensing Gas Furnace NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.
PG9MAB Condensing Gas Furnace Owner s Manual NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. USER: PLEASE READ ALL INSTRUCTIONS IN THE MANUAL AND RETAIN ALL MANUALS FOR FUTURE REFERENCE.
More informationHOME OWNER S INFORMATION High Efficiency Condensing Gas Furnace
HOME OWNER S INFORMATION High Efficiency Condensing Gas Furnace Our products are designed, tested and built in accordance with DOE standardized procedures; however, actual operating results and efficiencies
More informationIf the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY Do not store or use gasoline or other
More informationUSER S INFORMATION MANUAL
USER S INFORMATION MANUAL MODELS: All Residential Multi-position Gas Furnaces (33 Models) EFFICIENCY RATING CERTIFIED ISO 9001 Certified Quality Management System CONTACT INFORMATION...............................
More informationOwner s Manual CONDENSING GAS FURNACE ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.
CONDENSING GAS FURNACE Owner s Manual NOTE: Our products are designed, tested and built in accordance with DOE standardized procedures; however, actual operating results and efficiencies may vary based
More informationOwner s Manual. Condensing Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.
Condensing Gas Furnace Owner s Manual NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. USER: PLEASE READ ALL INSTRUCTIONS IN THE MANUAL AND RETAIN ALL MANUALS FOR FUTURE REFERENCE.
More informationOwner's Manual. Condensing Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.
Condensing Gas Furnace Owner's Manual NOTE: Our products are designed, tested and built in accordance with DOE standardized procedures; however, actual operating results and efficiencies may vary based
More informationKGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING
See unit nameplate for manufacturer and address. 506380 01 11/2009 KGA024, 030, 036, 048, 060, 072 (2, 2 1/2, 3, 4, 5, and 6 Tons) KGA092, 102, 120, 150 (7 1/2, 8-1/2, 10, and 12 Tons) KGA180, 210, 240,
More informationOwner s Manual CONDENSING GAS FURNACE ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.
CONDENSING GAS FURNACE Owner s Manual NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. USER: PLEASE READ ALL INSTRUCTIONS IN THE MANUAL AND RETAIN ALL MANUALS FOR FUTURE REFERENCE.
More informationOwner s Manual. Induced Combustion Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.
Induced Combustion Gas Furnace Owner s Manual NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. USER: Please read all instructions in the manual and retain all manuals for future reference.
More informationWHAT TO DO IF YOU SMELL GAS
AHE AHE SERIES 4 Direct Vent Wall-Mounted Boilers User s Information Manual If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal
More informationOwner s Manual CONDENSING GAS FURNACE ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.
CONDENSING GAS FURNACE Owner s Manual NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. USER: PLEASE READ ALL INSTRUCTIONS IN THE MANUAL AND RETAIN ALL MANUALS FOR FUTURE REFERENCE.
More informationUSER'S INFORMATION MANUAL
USER'S INFORMATION MANUAL SERIES ODVB GAS FIRED HOT WATER HEATING BOILER WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal
More informationUser s Information Manual
User s Information Manual Gas-fired water boilers Series 4 Featuring Flexibility Series 4 If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage,
More informationTGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS)
See unit nameplate for manufacturer and address. 506003 01 5/2009 Supersedes 1/2008 TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS) TGA090, 102, 120, 150, TGA120 SHOWN (7
More informationWHAT TO DO IF YOU SMELL GAS
GSA Gas-Fired Steam Boilers User s Information Manual Hazard definitions Hazards that will cause severe personal injury, death or substantial property damage. Hazards that can cause severe personal injury,
More informationOWNER S MANUAL PG9YAA HIGH EFFICIENCY GAS FURNACE ! WARNING SAFETY CONSIDERATIONS
HIGH EFFICIENCY GAS FURNACE OWNER S MANUAL NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. USER: Please read all instructions in the manual and retain all manuals for future reference.
More informationGWC. User s Information Manual. Gas-Fired Water Boilers. Model
Model GWC Gas-Fired Water Boilers User s Information Manual If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal injury or loss of
More informationSERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA
SERVICE FACTS Gas Furnaces Upflow & Downflow Induced Draft Stage Heat Models: M80P00AU2AA M80P060AU2AA M80P060AU36AA M80P080BU36AA M80P080BU8AA M80P00BU36AA M80P00CU8AA M80P00CU60AA M80PDU60AA M80P0DU60AA
More informationG95V NATURAL AND PROPANE GAS TWO STAGE HIGH EFFICIENCY (CONDENSING) WARM AIR FURNACE USER S INFORMATION MANUAL
G95V NATURAL AND PROPANE GAS TWO STAGE HIGH EFFICIENCY (CONDENSING) WARM AIR FURNACE USER S INFORMATION MANUAL An ISO 9001-2008 Certified Company 2201 Dwyer Avenue, Utica NY 13501 web site: www.ecrinternational.com
More informationOIL-FIRED CENTRAL FURNACE
OIL-FIRED CENTRAL FURNACE Installation, Operation, and Service Manual With Users Information Section Models: CSHB60-90XE CSHB60-90XP c WARNING: Do NOT store or use gasoline or other flammable vapors and
More informationUSER S INFORMATION MANUAL
USER S INFORMATION MANUAL UPFLOW & DOWNFLOW/HORIZONTAL TWO-STAGE SAFETY CONDENSING GAS FURNACES Recognize this symbol as an indication of Important Safety Information IMPORTANT: All manufacturer products
More informationUser s Information Manual Models:
FB-USER Rev C User s Information Manual Models:1.5-5.0 WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury
More informationUSER'S INFORMATION MANUAL
USER'S INFORMATION MANUAL SERIES JD GAS FIRED STEAM AND HOT WATER HEATING BOILER : If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal
More informationUSER S INFORMATION MANUAL FOR OPERATION AND MAINTENANCE OF YOUR GAS-FIRED FURNACE
MULTIPOISE, CONDENSING DIRECT VENT/NON-DIRECT VENT 8MCB, 8MTB, 8MVB, 8MXB GAS FURNACE USER S INFORMATION MANUAL FOR OPERATION AND MAINTENANCE OF YOUR GAS-FIRED FURNACE NOTE TO INSTALLER: THIS MANUAL MUST
More informationuser s information manual
user s information manual SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 580F Sizes 036-150 3 to 12 1 / 2 Tons Cancels: New OM11-18 10/15/00 NOTE TO INSTALLER This manual should be left with
More informationUser s Information Manual
CGa Series 2, CGi Series 3, EG Series 5, EGH Series 4, LGB Series 2, PEG Series 5 Gas-Fired Boilers User s Information Manual INSTALLER: Please take time to review this User s information Manual with the
More informationMODEL 340MAV, 350MAV, 352MAV, 355MAV CONDENSING GAS FURNACE
USER S INFORMATION MANUAL MODEL 340MAV, 30MAV, 32MAV, 3MAV CONDENSING GAS FURNACE USER: Please read all instructions in the manual and retain all manuals for future reference. NOTE TO INSTALLER: This manual
More informationOwner's Guide to Operating and Maintaining Your Gas/Electric Unit
Packaged Gas Heat/Electric Cooling Units Owner's Guide to Operating and Maintaining Your Gas/Electric Unit ELECTRICAL SHOCK. FIRE OR EXPLOSION Failure to follow this warning could result in personal injury,
More information