Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE
|
|
- Gertrude Nichols
- 6 years ago
- Views:
Transcription
1 Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE AUXB00A92A, AUXB060A92A, AUXB060A936A, AUXB080A92A, AUXB080A92A, AUXC080A960A, AUXC00A936A, AUXC00A98A, AUXD00A960A, AUXDA960A ADXB00A92A, ADXB060A936A, ADXB080A92A, ADXC00A98A, ADXDA960A Single-Stage Fan Assisted Combustion System PUB. NO
2 General Features NATURAL GAS MODELS Central Heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SAFE OPERATION The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety. QUICK HEATING Durable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside. BURNERS burners will give years of quiet and efficient service. All models can be converted to L.P. gas without changing burners. INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connection points for E.A.C./humidifier. AIR DELIVERY The four speed, direct drive blower motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. STYLING Heavy gauge steel and wrap-around cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. Built-in bottom pan and alternate bottom, left or right side return air connection provision. FEATURES AND GENERAL OPERATION The FREEDOM 90 Single Stage High Efficiency Gas Furnaces employ a Silicon Nitride system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter b. Vent proving pressure switch. 09 American Standard Heating & Air Conditioning
3 Features and Benefits Contents FREEDOM 90 Standard Equipment Power supply Convertible to horizontal left Type 29-C stainless steel secondary heat exchanger Inner blower doors Direct drive, -speed motors Silicon Nitride igniter with adaptive heat up Accessory hook-up capability Hum and EAC Quiet induced draft blower Blower door safety switch Dual solenoid combination gas valve & regulator PVC venting or 2 pipe vent option Left/right gas connection Selectable cooling fan off delay eliminates need for BAY2X05 time delay relay Single wire twinning Integrated solid state control with selfdiagnostics 2 volt fuse Manual reset burner box limit Optional extended warranties General Features 2 Features and Benefits 3 FREEDOM 90 Standard Equipment 3 FREEDOM 90 Optional Equipment General Data 5 AUXB00A92A 5 AUXB060A92A 5 AUXB060A936A 5 AUXB080A92A 5 AUXB080A92A 5 AUXC080A960A 5 AUXC00A936A 5 AUXC00A98A 6 AUXD00A960A 6 AUXDA960A 6 ADXB00A92A 7 ADXB060A936A 7 ADXB080A92A 7 ADXC00A98A 8 ADXDA960A 8 Performance Data 9 Electrical Data Field Wiring 3 Twinning Field Wiring Dimensions
4 Features and Benefits FREEDOM 90 Single Stage Optional Equipment Comfort Control, XL803, Programmable 7 Day, 3-Ht, 2-Cl... TCONT803AS32DA [ ] Comfort Control, XR02, Electric, 3-Ht, 2-Cl (n-programmable)... TCONT02AN32DA [ ] For additional comfort control choices, see the product catalog or quick select handbook Propane Conversion Kit... BAYLPKT20B [ ] Propane Conversion Kit (stainless steel burners)... BAYLPSS20B [ ] Wall Mount Flange 3"... BAY96X7 [ ] Wall Mount Flange 2"... BAY96X8 [ ] Downflow Subbase... BAYBASE5 [ ] Filter Access Door Kit... BAYFLTR6 [ ] Side Filter Rack... BAYFLTR0 [ ] High Altitude Pressure Switch Kit TUX00,00C960D; TDX00C... BAYHALT230 [ ] High Altitude Pressure Switch Kit TUX060C... BAYHALT23 [ ] High Altitude Pressure Switch Kit TUX080C... BAYHALT232 [ ] High Altitude Pressure Switch Kit TUX00C98D,C; TDX080,C... BAYHALT233 [ ] High Altitude Pressure Switch Kit TDX00C... BAYHALT23 [ ] High Altitude Pressure Switch Kit TDX060C... BAYHALT2 [ ] Concentric Vent Kit... BAYVENT00A [ ] Sidewall Vent Termination Kit... BAYVENT0B [ ] Manufactured/Mobile Home Kit...BAYMFGH00A [ ]
5 General Data Product Specifications MODEL TYPE RATINGS 2 Input BTUH Capacity BTUH (ICS) 3 AFUE (ICS) Temp. rise (Min.-Max.) F. BLOWER DRIVE Diameter - Width (In.). Used Speeds (.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive -. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER Furnished? Type Recommended Hi Vel. (.-Size-Thk.) AUXB00A92A Upflow / Horizontal 0,000 38, x 7 /5 075 / x25 - in. VENT PIPE DIA. Min (In.) 56 2 Round HEAT EXCHANGER Type-Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size 2 5 L.P. Gas Qty. Drill Size 2 56 GAS VALVE PILOT SAFETY DEVICE Type BURNERS Type Number 2 POWER CONN. V / Ph / Hz Ampacity (In Amps).8 Max. Overcurrent Protection (Amps) 5 PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) -3/ x 9- x 30- WEIGHT Shipping (Lbs.) / Net (Lbs) 39 / 29 AUXB060A92A Upflow / Horizontal 60,000 56, x 7 /3 075 / x25 - in. 2 Round / x 9- x / 0 AUXB060A936A Upflow / Horizontal 60,000 56, x 7 /3 075 / x25 - in. 2 Round / x 9- x / 0 AUXB080A92A Upflow / Horizontal 80,000 7, x 7 / x25 - in. 2 Round / x 9- x / 8 tes Central Furnace heating designs are certified by AGA and ETL. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate % per,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to,500 feet, derate % per,000 feet for elevations above,500 feet above sea level. 3 Based on U.S. government standard tests. The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 5 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length label located on the furnace. 6 All *UX and *DX furnace models have a vent outlet diameter that equals 2"
6 Product Specifications MODEL TYPE RATINGS 2 Input BTUH Capacity BTUH (ICS) 3 AFUE (ICS) Temp. rise (Min.-Max.) F. BLOWER DRIVE Diameter - Width (In.). Used Speeds (.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive -. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER Furnished? Type Recommended Hi Vel. (.-Size-Thk.) VENT PIPE DIAMETER Min (In.) 56 HEAT EXCHANGER Type-Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size L.P. Gas Qty. Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS Type Number POWER CONN. V / Ph / Hz Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) AUXB080A92A Upflow / Horizontal 80,000 7, x 8 / x25 - in. 2 Round / x 9- x / 8 AUXC080A960A Upflow / Horizontal 80,000 7, x 3/ x25 - in. 2.5 Round / x 23 x 30-7 / 60 AUXC00A936A Upflow / Horizontal 00,000 93, x / x25 - in. 2.5 Round / x 23 x 30-7 / 60 tes Central Furnace heating designs are certified by AGA and ETL. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate % per,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to,500 feet, derate % per,000 feet for elevations above,500 feet above sea level. 3 Based on U.S. government standard tests. The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 5 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length label located on the furnace. 6 All *UX and *DX furnace models have a vent outlet diameter that equals 2"
7 General Data Product Specifications MODEL TYPE RATINGS 2 Input BTUH Capacity BTUH (ICS) 3 AFUE (ICS) Temp. rise (Min.-Max.) F. BLOWER DRIVE Diameter - Width (In.). Used Speeds (.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive -. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER Furnished? Type Recommended Hi Vel. (.-Size-Thk.) VENT PIPE DIAMETER Min (In.) 56 HEAT EXCHANGER Type-Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size L.P. Gas Qty. Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS Type Number POWER CONN. V / Ph / Hz Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) AUXC00A98A Upflow / Horizontal 00,000 93, x / x25 - in. 2.5 Round / x 23 x 30-7 / 60 AUXD00A960A Upflow / Horizontal 00,000 93, x 0 3/ 00 / x25 - in. 2.5 Round / x 26- x / 85 AUXDA960A Upflow / Horizontal,000 3, x 0 3/ 00 / x25 - in. 3 Round / x 26- x 30-5 / 93 tes Central Furnace heating designs are certified by AGA and ETL. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate % per,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to,500 feet, derate % per,000 feet for elevations above,500 feet above sea level. 3 Based on U.S. government standard tests. The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 5 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length label located on the furnace. 6 All *UX and *DX furnace models have a vent outlet diameter that equals 2"
8 General Data Product Specifications MODEL TYPE RATINGS 2 Input BTUH Capacity BTUH (ICS) 3 AFUE (ICS) Temp. rise (Min.-Max.) F. BLOWER DRIVE Diameter - Width (In.). Used Speeds (.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive -. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER Furnished? Type Recommended Hi Vel. (.-Size-Thk.) VENT PIPE DIAMETER Min (In.) 56 HEAT EXCHANGER Type-Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size L.P. Gas Qty. Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS Type Number POWER CONN. V / Ph / Hz Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) ADXB00A92A Downflow / Horizontal 0,000 38, x 7 /5 080 / x - in. 2 Round / x 9- x 30-5 / 35 ADXB060A936A Downflow / Horizontal 60,000 56, x 8 /3 075 / x - in. 2 Round / x 9- x / 5 ADXB080A92A Downflow / Horizontal 80,000 7, x x - in. 2 Round / x 9- x / 58 tes Central Furnace heating designs are certified by AGA and ETL. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate % per,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to,500 feet, derate % per,000 feet for elevations above,500 feet above sea level. 3 Based on U.S. government standard tests. The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 5 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length label located on the furnace. 6 All *UX and *DX furnace models have a vent outlet diameter that equals 2"
9 General Data MODEL TYPE RATINGS 2 Input BTUH Capacity BTUH (ICS) 3 AFUE (ICS) Temp. rise (Min.-Max.) F. BLOWER DRIVE Diameter - Width (In.). Used Speeds (.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive -. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER Furnished? Type Recommended Hi Vel. (.-Size-Thk.) VENT PIPE DIAMETER Min (In.) 56 HEAT EXCHANGER Type-Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size L.P. Gas Qty. Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS Type Number POWER CONN. V / Ph / Hz Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) Product Specifications ADXC00A98A Downflow / Horizontal 00,000 9, x / x - in. 2.5 Round / x 23 x / 75 ADXDA960A Downflow / Horizontal,000 0, x 0 3/ 075 / x - in. 3 Round / x 26- x 30-6 / 96 tes Central Furnace heating designs are certified by AGA and ETL. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate % per,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to,500 feet, derate % per,000 feet for elevations above,500 feet above sea level. 3 Based on U.S. government standard tests. The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 5 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length label located on the furnace. 6 All *UX and *DX furnace models have a vent outlet diameter that equals 2"
10 Performance Data FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (in. w.c.) MODEL SPEED TAP AUXB00A92A AUXB060A92A AUXB060A936A AUXB080A92A AUXB080A92A AUXC080960A AUXC00A936A AUXC00A98A AUXD00A960A AUXDA960A - HIGH - Black - HIGH - Black - HIGH - Black - HIGH - Black - HIGH - Black - HIGH - Black - HIGH - Black - HIGH - Black - HIGH - Black - HIGH - Black NOTE: See page 2 for factory heat & cool speed tap settings From D Sh. Rev CFM VS. TEMPERATURE RISE Cubic Feet Per Minute (CFM) MODEL AUXB00A92A AUXB060A92A AUXB060A936A AUXB080A92A AUXB080A92A AUXC080A960A AUXC00A936A AUXC00A98A AUXD00A960A AUXDA960A From C3005 Sh. Rev
11 Performance Data FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (in. w.c.) MODEL SPEED TAP ADXB00A92A ADXB060A936A ADXB080A92A ADXC00A98A ADXDA960A - HIGH - Black - HIGH - Black - HIGH - Black - HIGH - Black - HIGH - Black From D33070 Rev CFM VS. TEMPERATURE RISE MODEL Cubic Feet Per Minute (CFM) ADXB00A92A ADXB060A936A ADXB080A92A ADXC00A98A ADXDA960A From C Sh. Rev
12 Electrical Data AUX Wiring From Dwg. D32565 Rev
13 AUX Schematic From Dwg. D32565 Rev
14 ADX Wiring From Dwg. D32566 Rev
15 Electrical Data ADX Schematic From Dwg. D32566 Rev
16 Field Wiring FIELD WIRING DIAGRAM FOR STAGE FURNACE STAGE HEATING USING A STAGE HEATING THERMOSTAT NO COOLING SEE NOTE 7 FURNACE TWIN B/C SEE NOTE 6 B/C TO 5 V PH., 60 HZ., POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 From Dwg. B337 Rev. FIELD WIRING DIAGRAM FOR STAGE FURNACE STAGE HEATING, STAGE COOLING USING A STAGE HEATING, STAGE COOLING THERMOSTAT (OUTDOOR SECTION WITHOUT TRANSFORMER) FURNACE OUTDOOR UNIT (NO TRANSFORMER) SEE NOTE 6 B/C SEE NOTE 8 B/C TO 5 V PH., 60 HZ., POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 From Dwg. B30388 Rev
17 Twinning Field Wiring TWINNING CONNECTION DIAGRAM FOR TWINNING STAGE FURNACES WITH SINGLE WIRE TWINNING FEATURE STAGE HEAT STAGE HEATING ONLY THERMOSTAT ONLY THERMOSTAT (WITH FAN SWITCH) FURNACE NO. FURNACE NO. 2 BLOWER OPERATION OF UNIT NO. 2 IS SYNCRONIZED WITH UNIT NO. VIA SIGNALS FROM TWIN CONNECTION. TWIN TWIN SEE NOTE ISOLATION RELAY (FIELD SUPPLIED) SEE NOTE R R ISOLATION RELAY SEE NOTE B/C SEE NOTE 3 B/C B/C From Dwg. 2B322 Rev. 3 OUTDOOR UNIT (WITH TRANSFORMER) TWINNING CONNECTION DIAGRAM FOR TWINNING STAGE FURNACES WITH SINGLE WIRE TWINNING FEATURE STAGE HEAT / STAGE COOL THERMOSTAT STAGE HEATING / COOLING THERMOSTAT FURNACE NO. FURNACE NO. 2 BLOWER OPERATION OF UNIT NO. 2 IS SYNCRONIZED WITH UNIT NO. VIA SIGNALS FROM TWIN CONNECTION. TWIN TWIN RC ISOLATION RELAY (FIELD SUPPLIED) SEE NOTE 3 SEE NOTE OUTDOOR UNIT (NO TRANSFORMER) R ISOLATION RELAY SEE NOTE B/C SEE NOTE 5 B/C R B/C ISOLATION RELAY (FIELD SUPPLIED) SEE NOTE From Dwg. 2B323 Rev
18 Dimensions AUX Outline Drawing (ALL DIMENSIONS ARE IN INCHES) From Dwg. C388 Rev
19 ADX Outline Drawing (ALL DIMENSIONS ARE IN INCHES) From Dwg. C3885 Rev
20 NOTES American Standard Heating & Air Conditioning 60 Troup Highway Tyler, TX Literature Order Number File Number Supersedes Date 0/09 American Standard Heating & Air Conditioning has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace
Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XR 95 TUHB00A92C, TUHB060A936C, TUHB080A92C, TUHC080A960C, TUHC00A98C, TUHD00A960C, TUHDA960C, TDHB00A92C, TDHB065A92C,
More informationUpflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace
Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XL 95 TUH2B060A936VA, TUH2B080A92VA, TUH2C100A98VA, TUH2D1A960VA, TDH2B060A936VA, TDH2B080A92VA, TDH2C100A98VA, TDH2D1A960VA
More informationDownflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace
Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace XR 80 TDDA00A92A, TDDA060A92A, TDDA060A936A, TDDB060A936A, TDDB080A936A, TDDB080A95A TDDB00A95A, TDDC00A98A, TDDC00A95A TDDCA95A,
More informationUpflow/Downflow Horizontal Right or Left Gas-Fired Furnace
Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace XT 80 TUDA00A9H2B, TUDB060A9H3B TUDB080A9H3B, TUDC080A9HB TUDB00A9H3B, TUDC00A9H5B TUDDA9H5B, TUDD0A9H5B TDDB060A9H3B, TDDB080A9H3B TDDC00A9H5B,
More informationUpflow/Horizontal Condensing, Gas-Fired Furnace
Upflow/Horizontal Condensing, Gas-Fired Furnace TDD-D-1 90% Furnace AUC1B00A921A, AUC1B060A9361A AUC1B080A921A, AUC1C100A981A AUC1D100A9601A, AUC1D120A9601A Single-Stage Fan Assisted Combustion System
More informationUpflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO
Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 TUC1B00A921A, TUC1B060A9361A TUC1B080A921A, TUC1C100A981A TUC1D100A9601A, TUC1D1A9601A Single-Stage Fan Assisted Combustion System PUB. NO. 22-1669-15
More informationUpflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XB 80 TDD-D-1 PUB. NO
Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace TDD-D- XB 80 TUEA00A92A, TUEA060A92A, TUEA060A936A TUEB060A936A, TUEB080A936A, TUEB080A98A TUEB00A936A, TUEC00A98A, TUEC00A960A
More informationUpflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80
Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80 TDD-D- TUDA00A92A, TUDA00A930A, TUDA060A92A, TUDA060A936A, TUDB060A936A, TUDB080A92A, TUDB080A936A, TUDB080A98A, TUDC080A960A,
More informationDownflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO
Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 TDC1B040A9241A, TDC1B060A9361A TDC1B080A9421A, TDC1C100A9481A TDC1D120A9601A Single-Stage Fan Assisted Combustion System PUB. NO. 22-1670-10 General
More informationUpflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80
Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80 TUDA00A92B, TUDA00A930B, TUDA060A92B, TUDA060A936B, TUDB060A936B, TUDB080A92B, TUDB080A936B, TUDB080A98B, TUDC080A960B,
More informationDownflow/Horizontal Right Induced Draft Gas Furnace
Downflow/Horizontal Right Induced Draft Gas Furnace American Standard 80 ADE1A060A9361A, ADE1B060A9361A ADE1B080A951A, ADE1B100A951A ADE1C100A9601A, ADE1D120A9601A Single-Stage Fan Assisted Combustion
More informationUpflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace
Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90 TUX060, 080, 100, 120R TDX060, 080, 100, 120R Direct Vent with Variable Speed Inducer PUB. NO. 22-1705-02-1202
More informationUpflow/ Downflow Horizontal Right or Left Gas-Fired Furnace
Upflow/ Downflow Horizontal Right or Left Gas-Fired Furnace Freedom 80 AUD2A00A922A, AUD2A060A9362A, AUD2B060A9362A, AUD2B080A9362A, AUD2B080A982A, AUD2B00A9362A, AUD2C00A982A, AUD2C00A9602A, AUD2D00A9602A,
More informationUpflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90
Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90 TUX2B060A9362A, TUX2B080A922A, TUX2C100A982A, TUX2D1A9602A, TDX2B060A9362A, TDX2B080A922A, TDX2C100A982A,
More informationXC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A
Upflow/Horizontal 2-Stage, Communicating Speed Gas Furnace XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D1ACV52A TUD2D140ACV52A TDD2B060ACV32A TDD2B080ACV32A TDD2C100ACV52A
More informationXV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO
Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner XV80i TUD2B060AFV32A, TUD2B080AFV32A, TUD2C080AFV42A, TUD2B100AFV32A, TUD2D120AFV52A 2009 Trane All Rights Reserved
More informationUpflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV
Upflow/Horizontal 2-Stage, Communicating Speed Gas Furnace Platinum SV AUD2B060ACV32A AUD2B080ACV32A AUD2C080ACV42A AUD2B100ACV32A AUD2C100ACV52A AUD2D120ACV52A AUD2D140ACV52A Two-Stage Fan Assisted Combustion
More informationSubmittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:
Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B080U4PSAA Note: Graphics in this document are
More informationSubmittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:
Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B040U3PSAA Note: Graphics in this document are
More informationSubmittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:
Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B080U3PSAA Note: Graphics in this document are
More informationSubmittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:
Submittal Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH Downflow Only S9V2C100D4PSAA Note: Graphics in this document are for representation only. Actual model may differ in appearance. SAFETY
More informationUpflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace
Product Data Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace Upflow, Convertible to HorizontalRight or HorizontalLeft S9X2B040U2PSAA S9X2B040U3PSAA S9X2B060U3PSAA S9X2B060U4PSAA
More informationSubmittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100U4PSBA TAG:
Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 100,000 BTUH Upflow, Convertible to HorizontalRight or HorizontalLeft S9V2C100U4PSBA Note:Graphics in this document are for
More informationSubmittal. Downflow Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080D3PSBA TAG:
Submittal Downflow Two Stage Condensing Gas Fired Furnace 80,000 BTUH Downflow Only S9V2B080D3PSBA Note:Graphics in this document are for representation only. Actual model may differ in appearance. SAFETYWARNING
More informationSubmittal. Downflow Two Stage Condensing Gas Fired Furnace 60,000 BTUH S9V2B060D3PSBA TAG:
Submittal Downflow Two Stage Condensing Gas Fired Furnace 60,000 BTUH Downflow Only S9V2B060D3PSBA Note:Graphics in this document are for representation only. Actual model may differ in appearance. SAFETYWARNING
More information80% and 95% furnace models feature aluminized steel heat exchangers to conduct heat quickly and increase durability.
FURNACES The Ameristar line of heating and cooling products offer you flexible and affordable options for HVAC equipment replacement. The Ameristar product line should complement the national brand you
More informationSERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA
SERVICE FACTS Gas Furnaces Upflow & Downflow Induced Draft Stage Heat Models: M80P00AU2AA M80P060AU2AA M80P060AU36AA M80P080BU36AA M80P080BU8AA M80P00BU36AA M80P00CU8AA M80P00CU60AA M80PDU60AA M80P0DU60AA
More informationSubmittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006
Submittal Prepared For: All Bidders Sold To: Date: January 8, 209 Customer P.O. Customer Project Job Job Name: City of Carrollton Fire Splits 623 Beltline Road CARROLLTON, TX 75006 Trane U.S. Inc. dba
More informationX341119P10 Gas Furnace Var. Speed Blower Var. Speed Inducer Two Stage Heat Direct Vent Models:
Service Facts X349P0 Gas Furnace Var. Speed Blower Var. Speed Inducer Two Stage Heat Direct Vent Models: *UY060R9V3W *UY080R9V3W *UY00R9V4W *UY20R9V5W * First letter may be A or T *DY060R9V3W *DY080R9V3W
More informationMERIT SERIES Downflow
PRODUCT SPECIFICATIONS GAS FURNACES ML80DF MERIT SERIES Downflow Bulletin No. 20643 February 208 Supersedes November 207 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling -.5 to 5 Tons MODEL
More informationPRODUCT SPECIFICATIONS 1 *UH2B080A942VA
UH2P-SF-1B Gas Furnace Direct Vent Condensing Two Stage Heat Models: * - First letter may be A or T *UH2B060A936VA *UH2B080A942VA *UH2C100A948VA *UH2D120A960VA *DH2B060A936VA *DH2B080A942VA *DH2C100A948VA
More informationGME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h
80% AFUE Multi-Position, TwinComfort Multi-Speed Gas Furnace Heating Input: 60,000 100,000 BTU/h Standard Features Patented dual-diameter tubular heat exchanger Two-stage gas valve that allows installer
More informationUpflow/ Horizontal Left/Right, Downflow Single and 2 Stage Non-Condensing Gas Fired Furnace
Product Data Upflow/ Horizontal Left/Right, Single and Stage Non-Condensing Gas Fired Furnace Upflow,, Horizontal Right/Left Single Stage S8XA06MPSAA S8XA00MPSAA S8XB00MPSAA S8XB060MPSAA S8XB060MPSAA S8XB080MPSAA
More informationM3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace
TECHNICAL SPECIFICATIONS M3RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 90+ AFUE Input 60,000 & 80,000 Btuh The high efficiency downflow gas furnace is especially
More information*DD2B060A9V3VA *DD2B080A9V3VA *DD2C100A9V5VA *DD2D120A9V5VA
UD2-9V-SF-C Gas Furnace Speed 2 Stage Heat Models: * - First letter may be A or T *UD2B060A9V3VB *UD2B080A9V3VB *UD2C080A9V4VB *UD2C080B9V4VB *UD2B00A9V3VB *UD2C00A9V5VB *UD2C00B9V5VB *UD2DA9V5VB *UD2DB9V5VB
More informationFor More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 95%+ AFUE Input 45,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially
More informationProduct Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING
DIRECT OR NON -DIRECT VENT 4-WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct Vent furnace S
More information13 GEP A L P - 1 A
PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800
More informationELITE SERIES Downflow - High Efficiency Blower Motor
PRODUCT SPECIFICATIONS GAS FURNACES EL80DFE ELITE SERIES Downflow - High Efficiency Blower Motor Bulletin No. 2066 July 208 Supersedes February 208 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on
More informationDM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h
Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE Heating Input: 60,000 100,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow Data... 5 Wiring Diagram...
More informationKG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS
TECHNICAL SPECIFICATIONS KG6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency
More informationG6RC Series TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS G6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency upfl
More informationFG7T (C and L Series)
TECHNICAL SPECIFICATIONS FG7T (C and L Series) WARRANTY Smartlite Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The
More informationADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h
ADSH8 Heating Input: 40,000 100,000 BTU/h Two-Stage Convertible Multi-Speed Gas Furnace 80% AFUE Standard Features Two-stage convertible gas valve automatically adjusts to high or low stage Durable SureStart
More informationTECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS Model PGF1TE 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 95.1 AFUE Direct Vent or Non Direct Vent Condensing Furnace 10 YEAR WARRANTY WORRY-FREE PERFORMANCE
More informationGMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h
/ Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE Heating Input: 40,000 120,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Specifications...7 Wiring Diagram...10
More informationMulti-Position Gas Furnaces
MODEL: Multi-Position Gas Furnaces FORM NO. GSC-552 Rev. 1 Sure Comfort 92% A.F.U.E. Multi-Position Gas Furnaces Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] 92% residential gas furnace
More informationRG7D 1-Stage Heat Series
TECHNICAL SPECIFICATIONS RG7D 1-Stage Heat Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace
More informationGMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH
GMS95 GAS $AVER 95% AFUE Multi-Position, Single-Stage/Multi-Speed Gas Furnace Heating Capacity: 46,000 115,000 BTUH 95% AFUE s Qualify for a $150 Tax Credit Standard Features Corrosion-resistant, aluminized-steel
More informationFEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).
This document was created with FrameMaker 4.0.4 SIZES AVAILABLE: 024065 through 060150 EFFICIENCY: IGNITION: HEAT EXCHANGER: CONTROL BOARD: The GA1A Induced-Combustion Gas Furnace provides the efficiency
More informationFORM NO. G REV. 4 Supersedes Form No. G Rev. 3
FORM NO. G66-538 REV. 4 Supersedes Form No. G66-536 Rev. 3 W95T- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] MULTI-POSITION GAS FURNACES Features 95% residential gas furnace
More informationGMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h
/ Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10
More informationGMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h
/ Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10
More informationGMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h
/ Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10
More informationRGE 13 A T - 1 A
PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE
More informationTECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES
036-1354-001 Rev. D (110) Heating TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE NATURAL GAS 37-111 MBH OUTPUT Air Conditioning EFFICIENCY RATING
More informationGMS9/GCS9 SERIES 93% AFUE
GMS9/GCS9 SERIES 93% AFUE Multi-Position, Single-Stage/Multi-Speed Gas Furnace Heating Capacity: 46,000 115,000 BTUH The GMS9/GCS9 single-stage, multi-speed gas furnaces offer installation versatility.
More informationRuud Achiever Plus Series Multi-position Gas Furnaces
Gas Furnaces Ruud Achiever Plus Series Multi-position Gas Furnaces R92T- Series 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated
More informationMULTI POSITION GAS FURNACE
FORM NO. GFJ-552 MULTI POSITION GAS FURNACE 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] Features 92% residential gas furnace CSA certified 4 way multi-poise design 7-Segment LED all
More information80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h
Series 80% AFUE Multi-Position, Dual$aver Multi-Speed Gas Furnace Heating Input: 70,000 115,000 BTU/h Standard Features Dual-diameter tubular heat exchanger Two-stage gas valve that allows installer to
More informationTZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )
FORM NO. GTZ-538 Supersedes Form No. GTZ-503 Rev. 1 TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 95% A.F.U.E. ) 95% A.F.U.E. MULTI POSITION GAS FURNACES Features
More informationKG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS KG6TE Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 95.1 Upflow/Horizontal The high effi ciency 2-Stage gas furnace
More informationTZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )
FORM NO. GTZ-539 REV. 2 Supersedes Form No. GTZ-503 Rev. 1 SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 96% A.F.U.E. ) TWO STAGE MULTI POSITION GAS FURNACES Features
More informationProduct Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price
Product Data 58PAV Energy-Efficient Induced-Combustion Upflow Furnace Input Capacities: 45,000 thru 155,000 Btuh 80% AFUE At Budget Price Carrier provides an 80 percent Annual Fuel Utilization Efficiency
More informationW92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )
FORM NO. G66-536 REV. 5 Supersedes Form No. G66-536 Rev. 3 W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (92% A.F.U.E. ) MULTI POSITION GAS FURNACES Features 92% residential
More informationGAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications
ENGINEERING DATA Typical Applications G20RE and G20RXE WhisperHeat DOWN-FLO GAS FURNACES *78.0% A.F.U.E. 50,000 to 150,000 Btuh Input Add-On Cooling 2 thru 5 Nominal Tons *Isolated Combustion System rating
More informationFG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS FG6T(C,L) Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 92+ Upflow/Horizontal 90+ Downflow The high effi ciency 2-Stage
More informationH9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)
H9MPV 2- Stage Variable Speed 9 Flexibility Dual Certified venting (1 or 2 pipe). Direct Vent Furnace 4 high with wider cabinets, for noise reduction and ease of installation. Factory shipped as natural
More informationTZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )
FORM NO. GTZ-540 Supersedes Form No. GTZ-503 Rev. 1 TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] (All Models 95% A.F.U.E. ) TWO STAGE VARIABLE SPEED MULTI POSITION GAS
More informationGMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace
Heating Input: 40,000 120,000 BTU/h / Single-Stage Multi-Speed Gas Furnace up to 96% AFUE Standard Features Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Single-stage
More informationSeries Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.
Gas Furnaces Ruud Achiever Plus Series Two- Stage Multi-position Gas Furnaces - Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated
More informationVNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL
VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL 25--21--65 Representative photo only, some models may vary in appearance. MANUFACTURED FOR NATURAL GAS CONVERTIBLE TO (LP) PROPANE GAS NOTE: These
More informationMULTI POSITION GAS FURNACE
FORM NO. GFJ-537 MULTI POSITION GAS FURNACE FF***PS95 Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] Features 95% residential gas furnace CSA certified 4 way multi-poise design
More informationWt. Lbs Model Number (BTUH) Hz
Up to 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions F95% AFUE in downflow position California NOx approved Most models have earned the ENERGY STAR
More informationCooling Capacity CFM in. w.c. (125 Pa)
93% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 93% AFUE, all models all positions F9MES 50 Hz Product Specifications Certified to leak 2% or less of nominal air conditioning CFM delivered when
More informationProduct Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input
Product Data 58EFA Horizontal Gas Furnace 50,000 125,000 Btuh Input GAS SUPPLY MANUAL SHUTOFF VALVE SEDIMENT TRAP UNION Carrier presents the 58EFA, a dedicated horizontal gas furnace that excels in the
More informationModel GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES
SIZES AVAILABLE: 024045 through 060155 EFFICIENCY: The GB1AAV Induced-Combustion Gas Furnace provides the efficiency customers want with 80% Annual Fuel Utilization Efficiency (AFUE). IGNITION: The field-proven
More informationFORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES
FORM NO. G11-489 REV. 2 Supersedes Form No. G11-489 Rev. 1 GAS FURNACES RGPR- SERIES ECM Equipped Models with Input Rates from 50,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single Phase [15 to 37 kw] (U.S.
More informationT9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)
T9MPV 2- Stage Variable Speed 9 Flexibility Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 4 high with wider cabinets, for ease of installation. Factory shipped as natural gas, with LP Gas conversion
More informationTECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.
036-1349-001 Rev. A (30) Heating TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 9 AFUE NATURAL GAS 37-130 MBH OUTPUT Air Conditioning EFFICIENCY RATING CERTIFIED R
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PGC2T (C and L) Series SmartStart M1200 Product Line Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces 95.1 AFUE Input 60,000-120,000
More informationRheem Classic Series Multi-position Gas Furnaces
Gas Furnaces Rheem Classic Series Multi-position Gas Furnaces R95P- Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance
More information8+* Bulletin No November 1997
ENGINEERING DATA VALUE 80Z UP-FLOW/HORIZONTAL GAS FURNACES *80.0 to 80.5% A.F.U.E. 45,000 to 20,000 Btuh (3.2 to 32.2 kw) Input Heating Capacity -/2 thru 6 Tons (3.5 thru 2. kw) Nominal Add-on Cooling
More informationG71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature
Service Literature Corp. 0804 L2 Revised 05 05 2008 G71MPP G71MPP SERIES UNITS G71MPP series units are high efficiency multi position (upflow, downflow, horizontal right and left) gas furnaces equipped
More informationCOMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES
FORM NO. GSC-493 REV. 3 Supersedes Form No. GSC-493 Rev. 2 GF902U*B SERIES Models with Input Rates of 45,000, 60,000, 75,000, 90,000 & 105,000 BTU/HR [13.19, 17.58, 22, 26.38 & 30.77 kw] 90 PLUS WITH DUAL
More information80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)
80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Series B approved for Twinning applications (0902116, 1002122, and 1352422) with accessory (order separately) Supports two stage cooling
More informationG60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature
Service Literature Corp. 0204 L2 Revised 11 2006 G60UH(X) G60UH(X) SERIES UNITS G60UH(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with
More informationCooling Capacity CFM range
R9MSB Product Specifications 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE all models in all positions California NOx approved Cabinet air leakage less than 2.0% at 1.0 in. W.C. and
More information395CAV Sizes 045 thru 155 Series H and J
ENERGY-EFFICIENT INDUCED-COMBUSTION DELUXE UPFLOW FURNACE 395CAV Sizes 045 thru 155 Series H and J With a unique approach to induced-combustion design, a 40-in. tall cabinet, 4-pass heat exchanger, an
More informationGAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)
FORM NO. G22-482 REV. 8 Supersedes Form No. G22-482 Rev. 7 GAS FURNACES RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above) 90 PLUS WITH DUAL COMFORT CONTROL
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PGF1RA Series M1010 Product Line High Efficiency / Upflow / Horizontal Gas Furnace Induced Draft - 80+ AFUEurnace 2 10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY
More informationProduct Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace. Series 120 Input Capacities: 40,000 thru 135,000 Btuh
Product Data 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace Series 120 Input Capacities: 40,000 thru 135,000 Btuh Comfort Heating for Energy-Efficient Gas Furnaces Carrier leads
More informationRheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces
Gas Furnaces Rheem Prestige Series Communicating Two Stage Variable Speed Multi position Gas Furnaces R96V- Series 96% A.F.U.E. Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] All Models except R96VA085
More information36,000-62,000 BTUH Nominal Capacity
36,000-62,000 BTUH Nominal Capacity STANDARD EQUIPMENT 2TEE3F62A, 4TEE3F62B VARIABLE SPEED AIR HANDLER Ships horizontal - converts to vertical by standing on end. Six-way convertibility-horizontal (left
More informationRheem Classic Plus Series Two Stage Multi position Gas Furnaces
Gas Furnaces Rheem Classic Plus Series Two Stage Multi position Gas Furnaces R96P- Series 96% A.F.U.E. * Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] A.F.U.E. (Annual Fuel Utilization Efficiency)
More informationSLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature
Service Literature Corp. 1029 L7 SLP98UHV SLP98UHV SERIES UNITS SLP98UHV series units are high efficiency upflow, horizontal right and left) gas furnaces equipped with variable capacity gas valve, variable
More informationCooling Capacity CFM in. w.c. (125 Pa)
R9MSB Product Specifications 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning
More information48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS
-3SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING S PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier Corporation
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PGF1TA 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 80+ Upflow/Horizontal 2 Stage Gas Furnace with Variable Speed Blower 2 10 YEAR WARRANTY WORRY-FREE
More informationProduct Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE
MULTIPOISE CONDENSING GAS Product Data INSTALLATION FLEXIBILITY The 4 -way multipoise design allows a model to be installed in an upflow, downflow, hizontal ientation. All sizes of the may be installed
More information