ECLIPSE AH-MA BURNERS. Air Make-Up Burners. Designed for trouble-free make-up or process air heating. Ready for the world
|
|
- Alisha Montgomery
- 6 years ago
- Views:
Transcription
1 Bulletin 16C 8/ ECLIPSE AH-MA BURNERS Air Make-Up Burners Designed for trouble-free make-up or process air heating. Eclipse AH-MA burners produce a uniform, odorless, and smokeless flame ideal for heating fresh air in make-up and process air heating applications. The AH-MA design provides stable operation over a wide range of velocities, inputs and fuels. AH-MA easily passes all global standards for indoor air quality through a wide operational range. It is ETL listed, complying with ANSI Z21.2 design standards, and is used in systems which meet ANSI Z83.4 / CGA 3.7 emissions standards for NOx and CO. The new aluminum burner body creates a lightweight, corrosion resistant burner. Cast iron and corrosion resistant cast iron bodies are also available. Divergent air wings are made of stainless steel. The burner bodies supply fuel to the center of the air wings to control the air and fuel mixture inside the burner and to optimize emissions and efficiency. Low pressure models require only a 6." w.c. ΔP natural gas at 8, Btu/hr/LF, making them ideal for use with the Maxitrol Selectra control valve. Ready for the world AH-MA burners combine advanced engineering with installation and operational features that are truly world class. Assembled from straight sections, tees and crosses to produce nearly any configuration required. Inputs up to 1,2, Btu/hr/LF Up to 3:1 turndown Up to 45 F upstream air temperature. Up to 85 F downstream air temperature. Multi-fuel capability (natural gas, propane and butane) In addition to the many user-preferred features of AH-MA, Eclipse offers you a comprehensive, global network of service with more years of air-heating experience than any other burner manufacturer. E C L I P S E
2 AH-MA Burners Ideal for make-up air heating applications Adjustable Profile Plate Uniform Air Flow Flame Length Burner Body Gas Feed Pipe Heated Air Uniform Air Flow Air WIng Adjustable Profile Plate Bulletin 16C 8/ Litho in USA
3 Data 16 11/7/4 AirHeat Burners AH-MA Series Version 2.2 Main Specifications Parameter Description Input (Btu/hr./ft.) Combustion Airstream Pressure Drop/Velocity Ignition Pilot Integral Pilot Capacities 1,2, maximum.2" to 1.4"w.c. Direct spark ignition (6VAC). Interruptible pilot for natural gas, propane or butane. 2, Btu/hr. Burner Bodies Standard Aluminum Low Pressure Aluminum* Standard Cast Iron Corrosion Resistant, EN Plated Cast Iron Low Pressure Cast Iron* Burner Section Sizes 15mm (6") straight section 3mm (12") straight section 3mm (12") straight section with back inlet 3mm (12") straight section with pilot 15mm (6") by 3mm (12") tee section 15mm (6") by 3mm (12") tee section with pilot 3mm (12") by 3mm (12") cross section Pipe Threads N.P.T. or B.S.P. Maximum Upstream Air Temp. 45 F (232 C) Maximum Downstream Air Temp. 85 F (454 C) Maximum Temperature Rise 75 F (4 C) Minimum Inlet Air Oxygen (O2) 18% Flame Detection** Flame rod or scanner. Fuels Natural gas, propane or butane. * For use with Natural Gas only. ** Burners over 5 lineal feet include flame supervision at the far end. If pilot ignition is being used, two flame supervision units are required; one for the pilot and one for the far end. If using direct spark on the main flame, only flame supervision at the far end is required providing ignition can be accomplished within 15 seconds. (Reference NFPA Requirement ) Eclipse reserves the right to change the construction and/or configurations of our products at any time without being obliged to adjust earlier supplies accordingly. All information is based on laboratory testing. Different chamber size and air flow conditions may affect the data. All information is based on standard conditions (7 F at sea level). Contact Eclipse for performance data above ambient temperature. All inputs based on gross caloric values.
4 Operating Range & Duct Pressure Measurement 1,3, 1,2, 1,1, 1,, Heat Input (Btu/hr./ft.) 9, 8, 7, 6, 5, 4, 3, 3, Maximum Heat Input Natural Gas Propane/Butane 25, 2, 15, Minimum Heat Input 1, 5, F Air Inlet Inlet Air Temperature Correction Air Press. Air Temp. = Air Press. Drop from Oper. Range Chart x Correction Factor Air Inlet Temp. ( F) Correction Factor Air Velocity Calculation Air Velocity (fpm) = ("w.c.) Air Density (lbs./cubic ft.) 2 Eclipse AH-MA AirHeat Burners v2.2, Data Sheet 16, 11/7/4
5 Differential Pressure Measurement & Burner Gas Pressure Drops "A" Tap On Inlet Gas Piping Main gas differential pressure measured between A and D 1-2" D (254-58mm) Gas Pressure Drop ("w.c.), Burner Inlet to Duct Natural Gas* Propane* Butane* Natural Gas (Low Press.)* * , 1,2 Heat Input (1 s Btu/hr./ft.) * 2.mm gas ports. * * 2.4mm gas ports Flame Lengths Flame Length Note: Flame length may vary slightly from these values depending on actual fuel, air handling system, duct configuratons and profile plates uses. Flame Length (Inches) "w.c..7"w.c. 1."w.c , 1,1 1,2 Heat Input (1 s Btu/hr./ft.) Emissions Data NOx 3% O2) "w.c. 3.7"w.c. 2 1."w.c , 1,2 Input (1 s Btu/hr./ft.) CO 3% O2) "w.c..7"w.c. 1."w.c , 1,2 Input (1 s Btu/hr./ft.) Eclipse AH-MA AirHeat Burners v2.2, Data Sheet 16, 11/7/4 3
ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH
ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH U.S. Reissue Pat. No. 26,244 Canadian Pat. No. 743,782 Spec 140 11/4/03 AH, Front View Data 140-1 AH, Back View Data 140-1 TAH Data 140-3 DAH, Blower
More informationEclipse AirHeat Burners
Design Guide No. 135, 7/99 L00060 Eclipse AirHeat Burners AH Series Version 2.00 (Patent Pending) Eclipse Combustion COPYRIGHT Copyright I999 by Eclipse Combustion, Inc. All rights reserved worldwide.
More informationEclipse AirHeat Burner
135 Design Guide 6/16/2010 Eclipse AirHeat Burner AH Serie Version 2 Copyright Copyright 1999 by Eclipse, Inc. All rights reserved worldwide. This publication is protected by federal regulation and shall
More informationSeries LV AIRFLO. In-duct firing line burner
Series LV AIRFLO In-duct firing line burner Duct burners - LV AIRFLO 4-21.4-1 Series LV AIRFLO burners provide stable, efficient, raw gas operations in air streams with relatively low duct velocities.
More informationSpecifications of V-Line burners
Duct Burners - V-Line 4-22.5-7 Specifications of V-Line burners V-Line burner firing on natural gas - constant combustion air 60 F - 21% O 2 combustion air - 50% rel. humidity - natural gas with 1000 Btu/ft³
More information"NP" & "RG" AIRFLO. In-duct firing line burner
"NP" & "RG" AIRFLO In-duct firing line burner Duct burners - NP & RG AIRFLO 4-21.5-1 For direct fired fresh air heating applications Operates economically (100 % thermal efficiency) and installs easily
More informationAPX. Nozzle-mix line burner
APX Nozzle-mix line burner Duct burners - APX Burner 4-21.9-1 Nozzle-mixing line burner for use with low pressure natural gas, propane and butane Eliminates leakage with its single-piece, aluminium extrusion
More informationEclipse AirHeat Burners AH Series version 2.00 (Patent Pending)
Installation Guide No. 135, 7/99 L00061 Eclipse AirHeat Burners AH Series version 2.00 (Patent Pending) Eclipse Combustion COPYRIGHT DISCLAIMER NOTICE LIABILITY AND WARRANTY Copyright 1999 by Eclipse Combustion,
More information"HC" AIRFLO. In-duct firing line burner
"HC" AIRFLO In-duct firing line burner -.- High heat release up to.5 MW per unit of burner length (05 mm) Clean combustion with low CO and NO x emission levels Minimal process air pressure drops locally
More informationV-Line. Nozzle-mix line burner
V-Line Nozzle-mix line burner Duct Burners - V-Line 4-22.5-1 Nozzle-mixing line burner for use with low pressure natural gas, propane and butane. Suitable for operation in variable process air-flows. Stainless
More informationDesign Guide 111 9/25/2008. Eclipse Winnox Burners WX Series Version 1
Design Guide 111 9/25/2008 Eclipse Winnox Burners WX Series Version 1 Co p y r i g h t Disclaimer Notice Copyright 2005 by Eclipse, Inc. All rights reserved worldwide. This publication is protected by
More informationDELTA-TE III. Nozzle-mix line burner
4-21.7-1 DELTA-TE III Nozzle-mix line burner Combines excellent flexibility with extreme low emissions for direct firing Especially designed for firing in low oxygen, high humidity and/or inert process
More informationLanemark Midco HMA2A Series Air Heating Burner and DB Duct Burner System Application Manual
Lanemark Midco HMA2A Series Air Heating Burner and DB Duct Burner System Application Manual HMA2A Burners DB Duct Burner Systems Contents Section 1 Section 2 Section 3 Section 4 Introduction Design Calculations
More informationEclipse ER Indirect Air Heater
Data 11 1/8/1 Eclipse ER Indirect Air Heater Version 1 Standard Efficiency (1/" Spacing Heat Exchanger) Parameter Air Delivery Temp., F ( C) 1 scfm referenced to 7 F at 1 atmosphere (1.9 psia), Nm /hr
More informationEcomax. Direct-Fired Self-Recuperative Metallic Gas Burner. Features
Ecomax Direct-Fired Self-Recuperative Metallic Gas Burner Features Self-recuperative design Heat resistant silicon carbide combustor and cast alloy recuperator Various recuperator lengths available Insulated
More informationECLIPSE INFORMATION GUIDE
ECLIPSE INFORMATION GUIDE JUNIOR INDUSTRIAL BURNERS Models 0 & 6 JIB Info 80 0/9 Easy to install and operate. Rugged construction for long life in industrial environments. Protection against overheating
More informationINDITHERM. Low temperature gas burners
INDITHERM Low temperature gas burners 1-2.3-1 High turndown for maximum operation flexibility. Maximum capacities up to 1800 kw. Designed for firing in indirect fired processes. Excellent combustion throughout
More informationMULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:
TANKLESS CONDENSING HIGH EFFICIENCY COMMERCIAL GAS Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to 0.95 Uniform Energy Factor (UEF) which lowers operating costs and
More informationECLIPSE INFORMATION GUIDE
ECLIPSE INFORMATION GUIDE EXTENSO-JET SMALL BORE BURNERS Info 230 8/91 CONTENTS PAGE CONTENTS PAGE Safe Burner Operation... 2 1.0 Applications... 2 2.0 Burner Operating Parameters & Requirements 2.1 Capacities
More informationC1050ES Tankless Water Heater
Engineering Submittal Sheet Dimensions and Connections B C D C Combustion air inlet Exhaust outlet Optional combustion air inlet Top view Top view A E F Hot water outlet Cold water inlet Inlet water filter
More informationDesign Guide No /01. RatioMatic Burners. RM Series Version 3.10
Design Guide No.110 12/01 RatioMatic Burners RM Series Version 3.10 COPYRIGHT Copyright I998 by Eclipse Combustion, Inc. All rights reserved worldwide. This publication is protected by federal regulation
More informationDESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS
DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS 1. Determine load requirements based on application () 2. Choose burner type based on process / application / requirements
More informationPYRO-LINE BURNERS 126LX 6LE 12LS DESCRIPTION MODEL: 3201
MODEL: 3201 Revision: 0 BULLETIN 3201 6LE 126LX 12LS DESCRIPTION PYRO-LINE Burners are cast iron, drilled port continuous line burners with alloy side rails. The unique mounting of the side rails improves
More informationResidential/Commercial Gas Condensing Tankless Models
15-Year Residential/1-Year Commercial Heat Exchanger Limited Warranty/5-Year Parts Warranty* FEATURES Ultra-Low NOx Condensing Technology Provides Unprecedented.95 Energy Factor Durable Heat Exchanger
More informationNMC Nozzle Mix Gas/Oil Combination Burners
NMC Nozzle Mix Gas/Oil Combination Burners NMC-1 Edition 10-08 Burns most gaseous fuels and No. 2 oil Sealed-in capability Stable flame over entire operating range Preheated air to 800ºF (425ºC) Gas pilot
More informationINDUSTRIAL MICRODIFFUSION OIL BURNERS
Operations and Maintenance Manual for INDUSTRIAL MICRODIFFUSION OIL BURNERS Models MD-25-O MD-2500-O December 2012 Copyright 2012 Periflame, Design Guide 112 Industrial Oil Burners, 12/01/2012 Page 1 Table
More informationBosch Greentherm T9800 SE 199 Gas Tankless Water Heater
Engineering Submittal Sheet Product Overview & Certifications Engineering Specifications The system shall consist of gas tankless water heater model Greentherm T9800 SE 199 as manufactured by Bosch Thermotechnology.
More informationINDITHERM. Low temperature gas burners
INDITHERM Low temperature gas burners 1-2.3-1 High turndown for maximum operation flexibility. Maximum capacities up to 1800 kw. Designed for firing in indirect fired processes. Excellent combustion throughout
More informationC1210ES Tankless Water Heater
Engineering Submittal Sheet Dimensions and Connections B C D C Combustion air inlet Exhaust outlet Optional combustion air inlet Top view Top view A E Hot water outlet Cold water inlet F H J C I K G Front
More informationDESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS
INTEGRAL FAN BURNERS 43, 53, 63 Supplement 600- July 996 DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS Integral Fan (and) Shutter Section (hinged for quick access to internals) Combustion Air Interlock
More informationDirect Fired Heater Model AD Specification
Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI
More informationiq251, Gen II Submittal Data
iq25, Gen II Submittal Data Date: Project Name: Bid Date: Fuel Type: Natural Gas Propane Project #: City State Zip: Engineer: Contractor: Factory Option: intouch-bms KEY FEATURES Stainless (36L) Heat Exchanger
More informationAir-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse
TANKLESS HIGH EFFICIENCY CONDENSING WATER HEATERS COMMERCIAL-GRADE RESIDENTIAL / COMMERCIAL Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to.95 Uniform Energy Factor
More informationOPERATING AND MAINTENANCE MANUAL
OPERATING AND MAINTENANCE MANUAL NVPOM-0104 TABLE OF CONTENTS Section Page 1 SPECIFICATIONS...1 1.1 Nova Plus Specifications...1-1 1.2 Warranty...1-2 2 GENERAL BURNER DESCRIPTION...2 2.1 Burner...2-1 2.2
More informationDesign Guide /12/2008. Eclipse RatioAir Burners RA Series Version 1
Design Guide 115 11/12/2008 Eclipse RatioAir Burners RA Series Version 1 Co p y r i g h t Disclaimer Notice Copyright 2005 by Eclipse, Inc. All rights reserved worldwide. This publication is protected
More informationTUBE-O-THERM Low Temperature Gas Burners
1-2.1-7 Specifications of TUBE-O-THERM burners 3 & 4 TUBE-O-THERM burners Typical burner data Fuel: natural gas at 60 F with 1000 Btu/ft 3 (st) HHV - sg = 0.6 [1] Combustion air: 60 F - 21% O 2-50% humidity
More informationResidential/Commercial Gas Condensing High Efficiency Tankless Water Heaters
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger
More informationTankless Condensing High Efficiency Water Heaters
Tankless Residential Water Heater Series Tankless Condensing High Efficiency Water Heaters Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to an unprecedented.95 Uniform
More informationResidential/Commercial Gas Tankless Water Heaters TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES INDOOR MODELS ATI-240H, ATI-340H, ATI-540H
TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger is constructed of HRS35 Commercial-Grade
More informationLine Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas
HVAC Guideline Specifications WHISPER-JET: SET SERIES Two Stage Positive Pressure Gas-Fired Infrared Radiant Tube Type Heater Commercial/Industrial Applications Technical Summary Input Range: 80,000/60,000
More informationEngineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004
Engineering Bulletin Gas Heat for M-Series and T-Series Climate Changer Air Handlers March 2004 CLCH-PRB010-EN Preface Gas heat can be a good heating option for any of the following applications: Climates
More informationSUBMITTAL SCHEDULE & DATA
SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Job Name: Date: 10/31/2016 Location: Engineer: Submitted by: Jeff Musto Architect: Contractor: Model
More information940ES Tankless Water Heater
Engineering Submittal Sheet Dimensions and Connections B C D C Combustion air inlet Exhaust outlet Optional combustion air inlet Top view Top view A Hot water outlet Cold water inlet E F Front view Side
More informationCOMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS
CONDENSING TANKLESS WITH INTEGRATED RECIRCULATION PUMP COMMERCIAL-GRADE RESIDENTIAL Ultra-Low NOx gas tankless water heaters with condensing technology featuring an up to 0.95 Uniform Energy Factor (UEF)
More informationSeasonal Efficiency Longevity Part-Load Efficiency Condensing Operation Fast ROI MODULEX BOILERS MLX-1060 MLX-909 MLX-757
Seasonal Efficiency Longevity Part-Load Efficiency Condensing Operation Fast ROI AERCO MODULEX BOILERS MLX-1060 MLX-909 MLX-757 MLX-606 MLX-454 MLX-303 Seasonal Efficiency Longevity Part-Load Efficiency
More information940ES Tankless Water Heater
Engineering Submittal Sheet Overview and Certifications LOW-LEAD U P C C US Massachusetts Plumbing Board Approved Engineering Specifications Water heater shall be a Model Therm 940 ES. Plant shall consist
More informationResidential Gas Tankless Water Heater
CONDENSING TANKLESS WITH INTEGRATED RECIRCULATION PUMP Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to a 0.95 Uniform Energy Factor (UEF) which lowers operating costs
More informationTankless Condensing High Efficiency Water Heaters with Built-In Pump
Tankless Residential Water Heater Series Tankless Condensing High Efficiency Water Heaters with Built-In Pump Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to an unprecedented
More informationSAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse
CONDENSING TANKLESS WITH INTEGRATED RECIRCULATION PUMP COMMERCIAL-GRADE RESIDENTIAL Ultra-Low NOx gas tankless water heaters with condensing technology featuring an up to 0.95 Uniform Energy Factor (UEF)
More informationINFRARED RADIANT HEATERS
IRH-1R INFRARED RADIANT HEATERS High and Low Intensity RSU SERIES Unit is shown rotated at a 45 angle. RSD SERIES HIGH INTENSITY INFRARED HEATERS RSD Series Ceramic Heaters Special Honeycomb Tile Design
More informationHeating Systems. Brooders, Space Heaters and QuadRadiant Heaters
Heating Systems Brooders, Space Heaters and QuadRadiant Heaters Let s grow together. QUADRATHERM QuadRadiant Heater Patent Pending With Chore-Time s QUADRATHERM Heater, the Most Innovative Concept in Heating
More informationA. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.
SECTION 15622 DIRECT GAS-FIRED BURNER & MANIFOLD SYSTEM PART 1: GENERAL 1.1 Section includes: A. Direct gas-fired heater modules B. Controls C. Equipment schedule 1.2 Related Sections A. Section 01655:
More informationCommercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY
TANKLESS WALL MOUNT LIGHTWEIGHT Constructed of anodized aluminum frame Utilizes the industry s lightest 199,000 BTU/h high efficiency condensing tankless heater EXPANDABLE Multiple design and installation
More information1500 SERIES SMALL CAPACITY ULTRA 2 LOW NO X TM BURNER
CAPABILITIES Similar design for hot or cold air Good turndown with flame characteristics and direction maintained Multiple gaseous fuel capabilities including commercial and many by-product fuels FEATURES
More informationFSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces
SG-UUH-03 November 2014 Specification Guide FSA, FOA, & HED Series Unit Heaters and Duct Furnaces Product improvement is a continuous process at Advanced Distributor Products. Therefore, product specifications
More informationBURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM
BURNERS/ FLARES VAREC BIOGAS 4W Series WASTE GAS BURNER & IGNITION SYSTEM The Varec Biogas 4W Series Waste Gas Burner is a highly reliable flare and ignition system ideal for use in burning excess biogas.
More informationGAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL
GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL POWER VENTED HD, HDB, PDP, BDP, PTP, BTP SEPARATED COMBUSTION HDS, HDC, PTS, BTS HIGH-EFFICIENCY SEPARATED COMBUSTION PTC, BTC 6-107.16 NOVEMBER,
More informationINFRA-RED BURNERS DESCRIPTION USES MODEL: 3207
MODEL: 3207 Revision: 0 BULLETIN 3207 DESCRIPTION The Infra-Red Burner is designed primarily for low temperature industrial process heating where heat transfer in the Infra-Red range is highly effective.
More informationSTS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS
SUBMITTAL DATA (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS PROJECT: ENGINEER: CONTRACTOR: DISTRIBUTOR: SCHWANK MODEL #: FUEL: APPROVED BY: DATE: APPROVAL #: 1 Submittal NOTICE:
More informationDesign and Application Details
Series 67 TUBE-O-FLAME Gas Burners Page 2203 Design and Application Details Maxon TUBE-O-FLAME Burners are nozzlemixing, gas-fired, refractory-less burners specifically designed for firing into an immersion
More informationGAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL
GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL POWER VENTED HD, HDB, PDP, BDP, PTP SEPARATED COMBUSTION HDS, HDC, PTS, BTS HIGH-EFFICIENCY SEPARATED COMBUSTION PTC, BTC 6-107.14 JULY, 2013
More informationINSTALLATION, OPERATION & MAINTENANCE MANUAL INDIRECT GAS-FIRED DUCT FURNACE
INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR COMMERCIAL APPLICATIONS IN-KI INDOOR SERIES RT-NO ROOFTOP SERIES WWW.RENEWAIRE.COM IMPORTANT SAFETY INFORMATION WARNING WARNING Risk of fire or explosion!
More informationSECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS
SECTION 237339 - DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary
More informationEclipse 90 UV Scanner Model A Version 1
85 Instruction Manual 10/14/010 Eclipse 90 UV Model 5600-90A Version 1 C US Introduction This sensor features a high sensitivity ultraviolet (UV) tube for monitoring gas or oil flames that cycle on and
More informationSpecifications of MULTIFIRE burners
-.-6 High temperature burners - MULTIFIRE Specifications of MULTIFIRE burners Gas firing Typical burner data Fuel: natural gas at 60 F with 000 tu/ft³ (st) HHV - sg = 0.6 [] Combustion air: 60 F - % O
More informationCommercial Tankless Rack System
TANKLESS FREE STANDING BACK-TO-BACK LIGHTWEIGHT Constructed of sturdy metal frame Utilizes the industry s lightest 199,000 BTU high efficiency condensing tankless heater EXPANDABLE Multiple design and
More informationUV Scanner. Model Specification. Introduction. 854 Instruction Manual
854 Instruction Manual 10/11/010 UV Model 5600-91 C US Introduction This sensor features a high temperature and high sensitivity ultraviolet (UV) tube for monitoring gas or oil flames in applications that
More informationKN-SERIES GAS-FIRED DIRECT VENT CAST IRON BOILERS KN-6 KN-10 KN-20
KN-Series boilers by HydroTherm may just be the biggest break-through in heating technology since fire itself. Think that s an overstatement? Consider this the KN-Series combines high 99% efficiency and
More informationInstallation Instructions
Model 500-SP OVENPAK Burners Page 2300-S-1 Installation Instructions General Instructions Important: Do not discard packing material until all loose items are accounted for. To prevent damage in transit,
More informationProduct Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input
Product Data 58EFA Horizontal Gas Furnace 50,000 125,000 Btuh Input GAS SUPPLY MANUAL SHUTOFF VALVE SEDIMENT TRAP UNION Carrier presents the 58EFA, a dedicated horizontal gas furnace that excels in the
More informationSAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER
SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER PART 1 GENERAL 1.01 RELATED DOCUMENTS A. ANSI Z21.13 American National Standard for Gas-Fired Low Pressure Steam and Hot Water Boilers B. ASME Section
More informationDIVISION FINNED WATER-TUBE BOILERS
HI DELTA, TYPE H - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 2000.953 Effective: 10-31-16 Replaces: NEW DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS - GENERAL 1.1 SUMMARY A. Section includes
More informationInternal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.
A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall
More informationMODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE
MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE PFS APPROVED FOR NATURAL GAS OR PROPANE GAS Z21.50-2014 If your plans do not allow for the venting system as outlined previously in the installing chimney/vent
More informationCommercial Tankless Rack System
TANKLESS WALL MOUNT LIGHTWEIGHT Constructed of anodized aluminum frame Utilizes the industry s lightest 199,000 BTU high efficiency condensing tankless heater EXPANDABLE Multiple design and installation
More informationEclipse RatioMatic Burners
Design Guide 110 11/11/2011 Eclipse RatioMatic Burners RM Series Version 5 Copyright Copyright 2010 by Eclipse, Inc. All rights reserved worldwide. This publication is protected by federal regulation and
More informationDIVISION FINNED WATER-TUBE WATER HEATERS
HI DELTA, TYPE WH - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 3500.932A Effective: 04-01-17 Replaces: 10-31-16 DIVISION 23 52 33.13 FINNED WATER-TUBE WATER HEATERS - GENERAL 1.1 SUMMARY A.
More informationSTR-Series Indirect-Fired Air Turnover Units
STR-Series Indirect-Fired Air Turnover Units Equipment Specifi cations 1.800.589.3691 www.weather-rite.com GAS/OIL HEATING ONLY INDIRECT-FIRED AIR TURNOVER UNIT GUIDE SPECIFICATIONS PART 1 GENERAL [Gas][Oil][Gas/Oil
More informationBoiler Basics. Design and operation
Boiler Basics Design and operation A boiler is an enclosed vessel that provides a means for combustion heat to be transferred into water until it becomes heated water or steam. The hot water or steam under
More informationCSD-1 COMMERCIAL BOILER CONTROLS
SUPPLEMENTAL INSTALLATION AND OPERATING INSTRUCTIONS CSD- COMMERCIAL BOILER CONTROLS P/N 400043, Rev. A [/03] CSD- COMMERCIAL BOILER CONTROLS! WARNING Fire, explosion, asphyxiation and electrical shock
More informationTypical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000
s AV(W)0500 AV(W) The domestic hot water boiler shall be a Camus ADVANTUS TM model having a recovery capacity of gph (lph) at 100ºF (56ºC) for DHW The domestic hot water boiler shall be design certified
More informationTypical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000
s AV(W)0500 AV(W) The domestic hot water boiler shall be a Camus ADVANTUS TM model having a recovery capacity of gph (lph) at 100ºF (56ºC) for DHW The domestic hot water boiler shall be design certified
More informationGUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS
GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS SECTION 15540 - FUEL - FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS)
More informationFLAT FLAME AND EXCESS AIR BURNERS
FLAT FLAME AND EXCESS AIR BURNERS SIDEWINDER - SW SERIES FEATURES Bulletin E303 rev04 31/01/00 Mixer body: cast iron G2 Plate: cast iron G2 Gas tube: AISI304 Pre-heated air: up to 40 Suitable for different
More informationCommercial. Phoenix. up to 96% Efficient Commercial Water Heater. Advanced Heating & Hot Water Systems
Commercial Advanced Heating & Hot Water Systems Phoenix up to 96% Efficient Commercial Water Heater SPECIFICATION GUIDE High limit safety sensor Low water cutoff sensor Upper (hot water) temperature sensor
More informationINFRA-RED BURNERS DESCRIPTION USES MODEL: 3207
MODEL: 3207 Revision: 0 BULLETIN 3207 DESCRIPTION The Infra-Red Burner is designed primarily for low temperature industrial process heating where heat transfer in the Infra-Red range is highly effective.
More informationTriton Series High Efficiency Boiler
Triton Series High Efficiency Boiler AJAX BOILER INC. Triton Series High Efficiency Boiler The new Atlas Triton Series boilers perform dependably and quietly, offering the most cost effective solutions
More informationPRE-PLANNING GUIDE for the Linear Burner System
PRE-PLANNING GUIDE for the Linear Burner System GAS PRESSURE SPARK products are engineered, safety tested and certified to function properly within a specific gas supply pressure range. It is CRITICALLY
More informationGAS-FIRED HIGH INTENSITY INFRARED HEATERS
GAS-FIRED HIGH INTENSITY INFRARED HEATERS CATALOG 9-116.1 MARCH, 2003 TABLE OF CONTENTS Modine's MT Series is a gas-fired, high intensity ceramic infrared heater. Ideal for spot heating, the MT series
More informationSOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE
TANKLESS WALL MOUNT LIGHTWEIGHT Constructed of anodized aluminum frame Utilizes the industry s lightest 199,000 BTU high efficiency condensing tankless heater EXPANDABLE Multiple design and installation
More informationU n i t H e at e r s
Unit Heaters LF Models Enduring performance Allied commercial unit heaters are built to last, season after season Designed and built for durability and peak performance, Allied Commercial unit heaters
More informationINFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:
INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS (CHECK ONE) PROPANE GAS PROJECT: ARCHITECT/ENGINEER: NAME: ADDRESS: NAME: ADDRESS: DATE: CONTRACTOR: SUBMITTED BY: NAME: ADDRESS: EQUIPMENT
More informationDIVISION FINNED WATER-TUBE WATER HEATERS
DELTA LIMITED, TYPE WH - MODELS 399B-899B SUGGESTED SPECIFICATIONS Catalog No.: 3500.97B Effective: 04-01-17 Replaces: 11-15-08 DIVISION 23 52 33.13 FINNED WATER-TUBE WATER HEATERS - GENERAL 1.1 SUMMARY
More informationHigh efficiency, cast-iron gas boiler
SENTRY High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler A smarter choice for informed The boiler you choose for your home
More informationC1210ESC Tankless Water Heater
Engineering Submittal Sheet Overview and ertifications L W LOW-LEAD U P US Massachusetts Plumbing Board Approved Engineering Specifications Water heater shall be a Model Therm 1210 ES. Plant shall consist
More informationCommercial Tankless Rack System
TANKLESS FREE STANDING BACK-TO-BACK LIGHTWEIGHT Constructed of sturdy metal frame Utilizes the industry s lightest 199,000 BTU high efficiency condensing tankless heater EXPANDABLE Multiple design and
More informationesfr dry pendent sprinkler Vk502 (k14.0)
Page 1 of 11 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Dry Pendent Sprinkler VK502 is a fast response fusible element type sprinkler designed for use in storage areas subject to freezing
More informationFIREYE FLAME SCANNERS
SC-103 JUNE 7, 2018 48PT1 (Obsolete) FIREYE S 48PT2 INFRARED: 48PT1, 48PT2 and 48PT2-CEX ROD: 69ND1 For UV Self-Check Scanners use SC-101 For Hazardous Locations or NEMA 4X Scanners use SC-106 For Non
More informationCommercial Tankless Rack System
TANKLESS WALL MOUNT LIGHTWEIGHT Constructed of anodized aluminum frame Utilizes the industry s lightest 199,000 BTU high efficiency condensing tankless heater EXPANDABLE Multiple design and installation
More informationT-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh
PRODUCT SPECIFICATIONS GAS UNIT HEATERS / DUCT FURNACES TU T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ Bulletin No. 20402 November 207 Supersedes November 206
More information