ECLIPSE AH-MA BURNERS. Air Make-Up Burners. Designed for trouble-free make-up or process air heating. Ready for the world

Size: px
Start display at page:

Download "ECLIPSE AH-MA BURNERS. Air Make-Up Burners. Designed for trouble-free make-up or process air heating. Ready for the world"

Transcription

1 Bulletin 16C 8/ ECLIPSE AH-MA BURNERS Air Make-Up Burners Designed for trouble-free make-up or process air heating. Eclipse AH-MA burners produce a uniform, odorless, and smokeless flame ideal for heating fresh air in make-up and process air heating applications. The AH-MA design provides stable operation over a wide range of velocities, inputs and fuels. AH-MA easily passes all global standards for indoor air quality through a wide operational range. It is ETL listed, complying with ANSI Z21.2 design standards, and is used in systems which meet ANSI Z83.4 / CGA 3.7 emissions standards for NOx and CO. The new aluminum burner body creates a lightweight, corrosion resistant burner. Cast iron and corrosion resistant cast iron bodies are also available. Divergent air wings are made of stainless steel. The burner bodies supply fuel to the center of the air wings to control the air and fuel mixture inside the burner and to optimize emissions and efficiency. Low pressure models require only a 6." w.c. ΔP natural gas at 8, Btu/hr/LF, making them ideal for use with the Maxitrol Selectra control valve. Ready for the world AH-MA burners combine advanced engineering with installation and operational features that are truly world class. Assembled from straight sections, tees and crosses to produce nearly any configuration required. Inputs up to 1,2, Btu/hr/LF Up to 3:1 turndown Up to 45 F upstream air temperature. Up to 85 F downstream air temperature. Multi-fuel capability (natural gas, propane and butane) In addition to the many user-preferred features of AH-MA, Eclipse offers you a comprehensive, global network of service with more years of air-heating experience than any other burner manufacturer. E C L I P S E

2 AH-MA Burners Ideal for make-up air heating applications Adjustable Profile Plate Uniform Air Flow Flame Length Burner Body Gas Feed Pipe Heated Air Uniform Air Flow Air WIng Adjustable Profile Plate Bulletin 16C 8/ Litho in USA

3 Data 16 11/7/4 AirHeat Burners AH-MA Series Version 2.2 Main Specifications Parameter Description Input (Btu/hr./ft.) Combustion Airstream Pressure Drop/Velocity Ignition Pilot Integral Pilot Capacities 1,2, maximum.2" to 1.4"w.c. Direct spark ignition (6VAC). Interruptible pilot for natural gas, propane or butane. 2, Btu/hr. Burner Bodies Standard Aluminum Low Pressure Aluminum* Standard Cast Iron Corrosion Resistant, EN Plated Cast Iron Low Pressure Cast Iron* Burner Section Sizes 15mm (6") straight section 3mm (12") straight section 3mm (12") straight section with back inlet 3mm (12") straight section with pilot 15mm (6") by 3mm (12") tee section 15mm (6") by 3mm (12") tee section with pilot 3mm (12") by 3mm (12") cross section Pipe Threads N.P.T. or B.S.P. Maximum Upstream Air Temp. 45 F (232 C) Maximum Downstream Air Temp. 85 F (454 C) Maximum Temperature Rise 75 F (4 C) Minimum Inlet Air Oxygen (O2) 18% Flame Detection** Flame rod or scanner. Fuels Natural gas, propane or butane. * For use with Natural Gas only. ** Burners over 5 lineal feet include flame supervision at the far end. If pilot ignition is being used, two flame supervision units are required; one for the pilot and one for the far end. If using direct spark on the main flame, only flame supervision at the far end is required providing ignition can be accomplished within 15 seconds. (Reference NFPA Requirement ) Eclipse reserves the right to change the construction and/or configurations of our products at any time without being obliged to adjust earlier supplies accordingly. All information is based on laboratory testing. Different chamber size and air flow conditions may affect the data. All information is based on standard conditions (7 F at sea level). Contact Eclipse for performance data above ambient temperature. All inputs based on gross caloric values.

4 Operating Range & Duct Pressure Measurement 1,3, 1,2, 1,1, 1,, Heat Input (Btu/hr./ft.) 9, 8, 7, 6, 5, 4, 3, 3, Maximum Heat Input Natural Gas Propane/Butane 25, 2, 15, Minimum Heat Input 1, 5, F Air Inlet Inlet Air Temperature Correction Air Press. Air Temp. = Air Press. Drop from Oper. Range Chart x Correction Factor Air Inlet Temp. ( F) Correction Factor Air Velocity Calculation Air Velocity (fpm) = ("w.c.) Air Density (lbs./cubic ft.) 2 Eclipse AH-MA AirHeat Burners v2.2, Data Sheet 16, 11/7/4

5 Differential Pressure Measurement & Burner Gas Pressure Drops "A" Tap On Inlet Gas Piping Main gas differential pressure measured between A and D 1-2" D (254-58mm) Gas Pressure Drop ("w.c.), Burner Inlet to Duct Natural Gas* Propane* Butane* Natural Gas (Low Press.)* * , 1,2 Heat Input (1 s Btu/hr./ft.) * 2.mm gas ports. * * 2.4mm gas ports Flame Lengths Flame Length Note: Flame length may vary slightly from these values depending on actual fuel, air handling system, duct configuratons and profile plates uses. Flame Length (Inches) "w.c..7"w.c. 1."w.c , 1,1 1,2 Heat Input (1 s Btu/hr./ft.) Emissions Data NOx 3% O2) "w.c. 3.7"w.c. 2 1."w.c , 1,2 Input (1 s Btu/hr./ft.) CO 3% O2) "w.c..7"w.c. 1."w.c , 1,2 Input (1 s Btu/hr./ft.) Eclipse AH-MA AirHeat Burners v2.2, Data Sheet 16, 11/7/4 3

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH U.S. Reissue Pat. No. 26,244 Canadian Pat. No. 743,782 Spec 140 11/4/03 AH, Front View Data 140-1 AH, Back View Data 140-1 TAH Data 140-3 DAH, Blower

More information

Eclipse AirHeat Burners

Eclipse AirHeat Burners Design Guide No. 135, 7/99 L00060 Eclipse AirHeat Burners AH Series Version 2.00 (Patent Pending) Eclipse Combustion COPYRIGHT Copyright I999 by Eclipse Combustion, Inc. All rights reserved worldwide.

More information

Eclipse AirHeat Burner

Eclipse AirHeat Burner 135 Design Guide 6/16/2010 Eclipse AirHeat Burner AH Serie Version 2 Copyright Copyright 1999 by Eclipse, Inc. All rights reserved worldwide. This publication is protected by federal regulation and shall

More information

Series LV AIRFLO. In-duct firing line burner

Series LV AIRFLO. In-duct firing line burner Series LV AIRFLO In-duct firing line burner Duct burners - LV AIRFLO 4-21.4-1 Series LV AIRFLO burners provide stable, efficient, raw gas operations in air streams with relatively low duct velocities.

More information

Specifications of V-Line burners

Specifications of V-Line burners Duct Burners - V-Line 4-22.5-7 Specifications of V-Line burners V-Line burner firing on natural gas - constant combustion air 60 F - 21% O 2 combustion air - 50% rel. humidity - natural gas with 1000 Btu/ft³

More information

"NP" & "RG" AIRFLO. In-duct firing line burner

NP & RG AIRFLO. In-duct firing line burner "NP" & "RG" AIRFLO In-duct firing line burner Duct burners - NP & RG AIRFLO 4-21.5-1 For direct fired fresh air heating applications Operates economically (100 % thermal efficiency) and installs easily

More information

APX. Nozzle-mix line burner

APX. Nozzle-mix line burner APX Nozzle-mix line burner Duct burners - APX Burner 4-21.9-1 Nozzle-mixing line burner for use with low pressure natural gas, propane and butane Eliminates leakage with its single-piece, aluminium extrusion

More information

Eclipse AirHeat Burners AH Series version 2.00 (Patent Pending)

Eclipse AirHeat Burners AH Series version 2.00 (Patent Pending) Installation Guide No. 135, 7/99 L00061 Eclipse AirHeat Burners AH Series version 2.00 (Patent Pending) Eclipse Combustion COPYRIGHT DISCLAIMER NOTICE LIABILITY AND WARRANTY Copyright 1999 by Eclipse Combustion,

More information

"HC" AIRFLO. In-duct firing line burner

HC AIRFLO. In-duct firing line burner "HC" AIRFLO In-duct firing line burner -.- High heat release up to.5 MW per unit of burner length (05 mm) Clean combustion with low CO and NO x emission levels Minimal process air pressure drops locally

More information

V-Line. Nozzle-mix line burner

V-Line. Nozzle-mix line burner V-Line Nozzle-mix line burner Duct Burners - V-Line 4-22.5-1 Nozzle-mixing line burner for use with low pressure natural gas, propane and butane. Suitable for operation in variable process air-flows. Stainless

More information

Design Guide 111 9/25/2008. Eclipse Winnox Burners WX Series Version 1

Design Guide 111 9/25/2008. Eclipse Winnox Burners WX Series Version 1 Design Guide 111 9/25/2008 Eclipse Winnox Burners WX Series Version 1 Co p y r i g h t Disclaimer Notice Copyright 2005 by Eclipse, Inc. All rights reserved worldwide. This publication is protected by

More information

DELTA-TE III. Nozzle-mix line burner

DELTA-TE III. Nozzle-mix line burner 4-21.7-1 DELTA-TE III Nozzle-mix line burner Combines excellent flexibility with extreme low emissions for direct firing Especially designed for firing in low oxygen, high humidity and/or inert process

More information

Lanemark Midco HMA2A Series Air Heating Burner and DB Duct Burner System Application Manual

Lanemark Midco HMA2A Series Air Heating Burner and DB Duct Burner System Application Manual Lanemark Midco HMA2A Series Air Heating Burner and DB Duct Burner System Application Manual HMA2A Burners DB Duct Burner Systems Contents Section 1 Section 2 Section 3 Section 4 Introduction Design Calculations

More information

Eclipse ER Indirect Air Heater

Eclipse ER Indirect Air Heater Data 11 1/8/1 Eclipse ER Indirect Air Heater Version 1 Standard Efficiency (1/" Spacing Heat Exchanger) Parameter Air Delivery Temp., F ( C) 1 scfm referenced to 7 F at 1 atmosphere (1.9 psia), Nm /hr

More information

Ecomax. Direct-Fired Self-Recuperative Metallic Gas Burner. Features

Ecomax. Direct-Fired Self-Recuperative Metallic Gas Burner. Features Ecomax Direct-Fired Self-Recuperative Metallic Gas Burner Features Self-recuperative design Heat resistant silicon carbide combustor and cast alloy recuperator Various recuperator lengths available Insulated

More information

ECLIPSE INFORMATION GUIDE

ECLIPSE INFORMATION GUIDE ECLIPSE INFORMATION GUIDE JUNIOR INDUSTRIAL BURNERS Models 0 & 6 JIB Info 80 0/9 Easy to install and operate. Rugged construction for long life in industrial environments. Protection against overheating

More information

INDITHERM. Low temperature gas burners

INDITHERM. Low temperature gas burners INDITHERM Low temperature gas burners 1-2.3-1 High turndown for maximum operation flexibility. Maximum capacities up to 1800 kw. Designed for firing in indirect fired processes. Excellent combustion throughout

More information

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES: TANKLESS CONDENSING HIGH EFFICIENCY COMMERCIAL GAS Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to 0.95 Uniform Energy Factor (UEF) which lowers operating costs and

More information

ECLIPSE INFORMATION GUIDE

ECLIPSE INFORMATION GUIDE ECLIPSE INFORMATION GUIDE EXTENSO-JET SMALL BORE BURNERS Info 230 8/91 CONTENTS PAGE CONTENTS PAGE Safe Burner Operation... 2 1.0 Applications... 2 2.0 Burner Operating Parameters & Requirements 2.1 Capacities

More information

C1050ES Tankless Water Heater

C1050ES Tankless Water Heater Engineering Submittal Sheet Dimensions and Connections B C D C Combustion air inlet Exhaust outlet Optional combustion air inlet Top view Top view A E F Hot water outlet Cold water inlet Inlet water filter

More information

Design Guide No /01. RatioMatic Burners. RM Series Version 3.10

Design Guide No /01. RatioMatic Burners. RM Series Version 3.10 Design Guide No.110 12/01 RatioMatic Burners RM Series Version 3.10 COPYRIGHT Copyright I998 by Eclipse Combustion, Inc. All rights reserved worldwide. This publication is protected by federal regulation

More information

DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS

DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS 1. Determine load requirements based on application () 2. Choose burner type based on process / application / requirements

More information

PYRO-LINE BURNERS 126LX 6LE 12LS DESCRIPTION MODEL: 3201

PYRO-LINE BURNERS 126LX 6LE 12LS DESCRIPTION MODEL: 3201 MODEL: 3201 Revision: 0 BULLETIN 3201 6LE 126LX 12LS DESCRIPTION PYRO-LINE Burners are cast iron, drilled port continuous line burners with alloy side rails. The unique mounting of the side rails improves

More information

Residential/Commercial Gas Condensing Tankless Models

Residential/Commercial Gas Condensing Tankless Models 15-Year Residential/1-Year Commercial Heat Exchanger Limited Warranty/5-Year Parts Warranty* FEATURES Ultra-Low NOx Condensing Technology Provides Unprecedented.95 Energy Factor Durable Heat Exchanger

More information

NMC Nozzle Mix Gas/Oil Combination Burners

NMC Nozzle Mix Gas/Oil Combination Burners NMC Nozzle Mix Gas/Oil Combination Burners NMC-1 Edition 10-08 Burns most gaseous fuels and No. 2 oil Sealed-in capability Stable flame over entire operating range Preheated air to 800ºF (425ºC) Gas pilot

More information

INDUSTRIAL MICRODIFFUSION OIL BURNERS

INDUSTRIAL MICRODIFFUSION OIL BURNERS Operations and Maintenance Manual for INDUSTRIAL MICRODIFFUSION OIL BURNERS Models MD-25-O MD-2500-O December 2012 Copyright 2012 Periflame, Design Guide 112 Industrial Oil Burners, 12/01/2012 Page 1 Table

More information

Bosch Greentherm T9800 SE 199 Gas Tankless Water Heater

Bosch Greentherm T9800 SE 199 Gas Tankless Water Heater Engineering Submittal Sheet Product Overview & Certifications Engineering Specifications The system shall consist of gas tankless water heater model Greentherm T9800 SE 199 as manufactured by Bosch Thermotechnology.

More information

INDITHERM. Low temperature gas burners

INDITHERM. Low temperature gas burners INDITHERM Low temperature gas burners 1-2.3-1 High turndown for maximum operation flexibility. Maximum capacities up to 1800 kw. Designed for firing in indirect fired processes. Excellent combustion throughout

More information

C1210ES Tankless Water Heater

C1210ES Tankless Water Heater Engineering Submittal Sheet Dimensions and Connections B C D C Combustion air inlet Exhaust outlet Optional combustion air inlet Top view Top view A E Hot water outlet Cold water inlet F H J C I K G Front

More information

DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS

DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS INTEGRAL FAN BURNERS 43, 53, 63 Supplement 600- July 996 DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS Integral Fan (and) Shutter Section (hinged for quick access to internals) Combustion Air Interlock

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information

iq251, Gen II Submittal Data

iq251, Gen II Submittal Data iq25, Gen II Submittal Data Date: Project Name: Bid Date: Fuel Type: Natural Gas Propane Project #: City State Zip: Engineer: Contractor: Factory Option: intouch-bms KEY FEATURES Stainless (36L) Heat Exchanger

More information

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse TANKLESS HIGH EFFICIENCY CONDENSING WATER HEATERS COMMERCIAL-GRADE RESIDENTIAL / COMMERCIAL Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to.95 Uniform Energy Factor

More information

OPERATING AND MAINTENANCE MANUAL

OPERATING AND MAINTENANCE MANUAL OPERATING AND MAINTENANCE MANUAL NVPOM-0104 TABLE OF CONTENTS Section Page 1 SPECIFICATIONS...1 1.1 Nova Plus Specifications...1-1 1.2 Warranty...1-2 2 GENERAL BURNER DESCRIPTION...2 2.1 Burner...2-1 2.2

More information

Design Guide /12/2008. Eclipse RatioAir Burners RA Series Version 1

Design Guide /12/2008. Eclipse RatioAir Burners RA Series Version 1 Design Guide 115 11/12/2008 Eclipse RatioAir Burners RA Series Version 1 Co p y r i g h t Disclaimer Notice Copyright 2005 by Eclipse, Inc. All rights reserved worldwide. This publication is protected

More information

TUBE-O-THERM Low Temperature Gas Burners

TUBE-O-THERM Low Temperature Gas Burners 1-2.1-7 Specifications of TUBE-O-THERM burners 3 & 4 TUBE-O-THERM burners Typical burner data Fuel: natural gas at 60 F with 1000 Btu/ft 3 (st) HHV - sg = 0.6 [1] Combustion air: 60 F - 21% O 2-50% humidity

More information

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger

More information

Tankless Condensing High Efficiency Water Heaters

Tankless Condensing High Efficiency Water Heaters Tankless Residential Water Heater Series Tankless Condensing High Efficiency Water Heaters Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to an unprecedented.95 Uniform

More information

Residential/Commercial Gas Tankless Water Heaters TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES INDOOR MODELS ATI-240H, ATI-340H, ATI-540H

Residential/Commercial Gas Tankless Water Heaters TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES INDOOR MODELS ATI-240H, ATI-340H, ATI-540H TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger is constructed of HRS35 Commercial-Grade

More information

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas HVAC Guideline Specifications WHISPER-JET: SET SERIES Two Stage Positive Pressure Gas-Fired Infrared Radiant Tube Type Heater Commercial/Industrial Applications Technical Summary Input Range: 80,000/60,000

More information

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004 Engineering Bulletin Gas Heat for M-Series and T-Series Climate Changer Air Handlers March 2004 CLCH-PRB010-EN Preface Gas heat can be a good heating option for any of the following applications: Climates

More information

SUBMITTAL SCHEDULE & DATA

SUBMITTAL SCHEDULE & DATA SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Job Name: Date: 10/31/2016 Location: Engineer: Submitted by: Jeff Musto Architect: Contractor: Model

More information

940ES Tankless Water Heater

940ES Tankless Water Heater Engineering Submittal Sheet Dimensions and Connections B C D C Combustion air inlet Exhaust outlet Optional combustion air inlet Top view Top view A Hot water outlet Cold water inlet E F Front view Side

More information

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS CONDENSING TANKLESS WITH INTEGRATED RECIRCULATION PUMP COMMERCIAL-GRADE RESIDENTIAL Ultra-Low NOx gas tankless water heaters with condensing technology featuring an up to 0.95 Uniform Energy Factor (UEF)

More information

Seasonal Efficiency Longevity Part-Load Efficiency Condensing Operation Fast ROI MODULEX BOILERS MLX-1060 MLX-909 MLX-757

Seasonal Efficiency Longevity Part-Load Efficiency Condensing Operation Fast ROI MODULEX BOILERS MLX-1060 MLX-909 MLX-757 Seasonal Efficiency Longevity Part-Load Efficiency Condensing Operation Fast ROI AERCO MODULEX BOILERS MLX-1060 MLX-909 MLX-757 MLX-606 MLX-454 MLX-303 Seasonal Efficiency Longevity Part-Load Efficiency

More information

940ES Tankless Water Heater

940ES Tankless Water Heater Engineering Submittal Sheet Overview and Certifications LOW-LEAD U P C C US Massachusetts Plumbing Board Approved Engineering Specifications Water heater shall be a Model Therm 940 ES. Plant shall consist

More information

Residential Gas Tankless Water Heater

Residential Gas Tankless Water Heater CONDENSING TANKLESS WITH INTEGRATED RECIRCULATION PUMP Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to a 0.95 Uniform Energy Factor (UEF) which lowers operating costs

More information

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

Tankless Condensing High Efficiency Water Heaters with Built-In Pump Tankless Residential Water Heater Series Tankless Condensing High Efficiency Water Heaters with Built-In Pump Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to an unprecedented

More information

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse CONDENSING TANKLESS WITH INTEGRATED RECIRCULATION PUMP COMMERCIAL-GRADE RESIDENTIAL Ultra-Low NOx gas tankless water heaters with condensing technology featuring an up to 0.95 Uniform Energy Factor (UEF)

More information

INFRARED RADIANT HEATERS

INFRARED RADIANT HEATERS IRH-1R INFRARED RADIANT HEATERS High and Low Intensity RSU SERIES Unit is shown rotated at a 45 angle. RSD SERIES HIGH INTENSITY INFRARED HEATERS RSD Series Ceramic Heaters Special Honeycomb Tile Design

More information

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters Heating Systems Brooders, Space Heaters and QuadRadiant Heaters Let s grow together. QUADRATHERM QuadRadiant Heater Patent Pending With Chore-Time s QUADRATHERM Heater, the Most Innovative Concept in Heating

More information

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters. SECTION 15622 DIRECT GAS-FIRED BURNER & MANIFOLD SYSTEM PART 1: GENERAL 1.1 Section includes: A. Direct gas-fired heater modules B. Controls C. Equipment schedule 1.2 Related Sections A. Section 01655:

More information

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY TANKLESS WALL MOUNT LIGHTWEIGHT Constructed of anodized aluminum frame Utilizes the industry s lightest 199,000 BTU/h high efficiency condensing tankless heater EXPANDABLE Multiple design and installation

More information

1500 SERIES SMALL CAPACITY ULTRA 2 LOW NO X TM BURNER

1500 SERIES SMALL CAPACITY ULTRA 2 LOW NO X TM BURNER CAPABILITIES Similar design for hot or cold air Good turndown with flame characteristics and direction maintained Multiple gaseous fuel capabilities including commercial and many by-product fuels FEATURES

More information

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces SG-UUH-03 November 2014 Specification Guide FSA, FOA, & HED Series Unit Heaters and Duct Furnaces Product improvement is a continuous process at Advanced Distributor Products. Therefore, product specifications

More information

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM BURNERS/ FLARES VAREC BIOGAS 4W Series WASTE GAS BURNER & IGNITION SYSTEM The Varec Biogas 4W Series Waste Gas Burner is a highly reliable flare and ignition system ideal for use in burning excess biogas.

More information

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL POWER VENTED HD, HDB, PDP, BDP, PTP, BTP SEPARATED COMBUSTION HDS, HDC, PTS, BTS HIGH-EFFICIENCY SEPARATED COMBUSTION PTC, BTC 6-107.16 NOVEMBER,

More information

INFRA-RED BURNERS DESCRIPTION USES MODEL: 3207

INFRA-RED BURNERS DESCRIPTION USES MODEL: 3207 MODEL: 3207 Revision: 0 BULLETIN 3207 DESCRIPTION The Infra-Red Burner is designed primarily for low temperature industrial process heating where heat transfer in the Infra-Red range is highly effective.

More information

STS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS

STS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS SUBMITTAL DATA (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS PROJECT: ENGINEER: CONTRACTOR: DISTRIBUTOR: SCHWANK MODEL #: FUEL: APPROVED BY: DATE: APPROVAL #: 1 Submittal NOTICE:

More information

Design and Application Details

Design and Application Details Series 67 TUBE-O-FLAME Gas Burners Page 2203 Design and Application Details Maxon TUBE-O-FLAME Burners are nozzlemixing, gas-fired, refractory-less burners specifically designed for firing into an immersion

More information

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL POWER VENTED HD, HDB, PDP, BDP, PTP SEPARATED COMBUSTION HDS, HDC, PTS, BTS HIGH-EFFICIENCY SEPARATED COMBUSTION PTC, BTC 6-107.14 JULY, 2013

More information

INSTALLATION, OPERATION & MAINTENANCE MANUAL INDIRECT GAS-FIRED DUCT FURNACE

INSTALLATION, OPERATION & MAINTENANCE MANUAL INDIRECT GAS-FIRED DUCT FURNACE INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR COMMERCIAL APPLICATIONS IN-KI INDOOR SERIES RT-NO ROOFTOP SERIES WWW.RENEWAIRE.COM IMPORTANT SAFETY INFORMATION WARNING WARNING Risk of fire or explosion!

More information

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS SECTION 237339 - DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

Eclipse 90 UV Scanner Model A Version 1

Eclipse 90 UV Scanner Model A Version 1 85 Instruction Manual 10/14/010 Eclipse 90 UV Model 5600-90A Version 1 C US Introduction This sensor features a high sensitivity ultraviolet (UV) tube for monitoring gas or oil flames that cycle on and

More information

Specifications of MULTIFIRE burners

Specifications of MULTIFIRE burners -.-6 High temperature burners - MULTIFIRE Specifications of MULTIFIRE burners Gas firing Typical burner data Fuel: natural gas at 60 F with 000 tu/ft³ (st) HHV - sg = 0.6 [] Combustion air: 60 F - % O

More information

Commercial Tankless Rack System

Commercial Tankless Rack System TANKLESS FREE STANDING BACK-TO-BACK LIGHTWEIGHT Constructed of sturdy metal frame Utilizes the industry s lightest 199,000 BTU high efficiency condensing tankless heater EXPANDABLE Multiple design and

More information

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

UV Scanner. Model Specification. Introduction. 854 Instruction Manual 854 Instruction Manual 10/11/010 UV Model 5600-91 C US Introduction This sensor features a high temperature and high sensitivity ultraviolet (UV) tube for monitoring gas or oil flames in applications that

More information

KN-SERIES GAS-FIRED DIRECT VENT CAST IRON BOILERS KN-6 KN-10 KN-20

KN-SERIES GAS-FIRED DIRECT VENT CAST IRON BOILERS KN-6 KN-10 KN-20 KN-Series boilers by HydroTherm may just be the biggest break-through in heating technology since fire itself. Think that s an overstatement? Consider this the KN-Series combines high 99% efficiency and

More information

Installation Instructions

Installation Instructions Model 500-SP OVENPAK Burners Page 2300-S-1 Installation Instructions General Instructions Important: Do not discard packing material until all loose items are accounted for. To prevent damage in transit,

More information

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input Product Data 58EFA Horizontal Gas Furnace 50,000 125,000 Btuh Input GAS SUPPLY MANUAL SHUTOFF VALVE SEDIMENT TRAP UNION Carrier presents the 58EFA, a dedicated horizontal gas furnace that excels in the

More information

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER PART 1 GENERAL 1.01 RELATED DOCUMENTS A. ANSI Z21.13 American National Standard for Gas-Fired Low Pressure Steam and Hot Water Boilers B. ASME Section

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS HI DELTA, TYPE H - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 2000.953 Effective: 10-31-16 Replaces: NEW DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS - GENERAL 1.1 SUMMARY A. Section includes

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE PFS APPROVED FOR NATURAL GAS OR PROPANE GAS Z21.50-2014 If your plans do not allow for the venting system as outlined previously in the installing chimney/vent

More information

Commercial Tankless Rack System

Commercial Tankless Rack System TANKLESS WALL MOUNT LIGHTWEIGHT Constructed of anodized aluminum frame Utilizes the industry s lightest 199,000 BTU high efficiency condensing tankless heater EXPANDABLE Multiple design and installation

More information

Eclipse RatioMatic Burners

Eclipse RatioMatic Burners Design Guide 110 11/11/2011 Eclipse RatioMatic Burners RM Series Version 5 Copyright Copyright 2010 by Eclipse, Inc. All rights reserved worldwide. This publication is protected by federal regulation and

More information

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS HI DELTA, TYPE WH - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 3500.932A Effective: 04-01-17 Replaces: 10-31-16 DIVISION 23 52 33.13 FINNED WATER-TUBE WATER HEATERS - GENERAL 1.1 SUMMARY A.

More information

STR-Series Indirect-Fired Air Turnover Units

STR-Series Indirect-Fired Air Turnover Units STR-Series Indirect-Fired Air Turnover Units Equipment Specifi cations 1.800.589.3691 www.weather-rite.com GAS/OIL HEATING ONLY INDIRECT-FIRED AIR TURNOVER UNIT GUIDE SPECIFICATIONS PART 1 GENERAL [Gas][Oil][Gas/Oil

More information

Boiler Basics. Design and operation

Boiler Basics. Design and operation Boiler Basics Design and operation A boiler is an enclosed vessel that provides a means for combustion heat to be transferred into water until it becomes heated water or steam. The hot water or steam under

More information

CSD-1 COMMERCIAL BOILER CONTROLS

CSD-1 COMMERCIAL BOILER CONTROLS SUPPLEMENTAL INSTALLATION AND OPERATING INSTRUCTIONS CSD- COMMERCIAL BOILER CONTROLS P/N 400043, Rev. A [/03] CSD- COMMERCIAL BOILER CONTROLS! WARNING Fire, explosion, asphyxiation and electrical shock

More information

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000 s AV(W)0500 AV(W) The domestic hot water boiler shall be a Camus ADVANTUS TM model having a recovery capacity of gph (lph) at 100ºF (56ºC) for DHW The domestic hot water boiler shall be design certified

More information

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000 s AV(W)0500 AV(W) The domestic hot water boiler shall be a Camus ADVANTUS TM model having a recovery capacity of gph (lph) at 100ºF (56ºC) for DHW The domestic hot water boiler shall be design certified

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS SECTION 15540 - FUEL - FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS)

More information

FLAT FLAME AND EXCESS AIR BURNERS

FLAT FLAME AND EXCESS AIR BURNERS FLAT FLAME AND EXCESS AIR BURNERS SIDEWINDER - SW SERIES FEATURES Bulletin E303 rev04 31/01/00 Mixer body: cast iron G2 Plate: cast iron G2 Gas tube: AISI304 Pre-heated air: up to 40 Suitable for different

More information

Commercial. Phoenix. up to 96% Efficient Commercial Water Heater. Advanced Heating & Hot Water Systems

Commercial. Phoenix. up to 96% Efficient Commercial Water Heater. Advanced Heating & Hot Water Systems Commercial Advanced Heating & Hot Water Systems Phoenix up to 96% Efficient Commercial Water Heater SPECIFICATION GUIDE High limit safety sensor Low water cutoff sensor Upper (hot water) temperature sensor

More information

INFRA-RED BURNERS DESCRIPTION USES MODEL: 3207

INFRA-RED BURNERS DESCRIPTION USES MODEL: 3207 MODEL: 3207 Revision: 0 BULLETIN 3207 DESCRIPTION The Infra-Red Burner is designed primarily for low temperature industrial process heating where heat transfer in the Infra-Red range is highly effective.

More information

Triton Series High Efficiency Boiler

Triton Series High Efficiency Boiler Triton Series High Efficiency Boiler AJAX BOILER INC. Triton Series High Efficiency Boiler The new Atlas Triton Series boilers perform dependably and quietly, offering the most cost effective solutions

More information

PRE-PLANNING GUIDE for the Linear Burner System

PRE-PLANNING GUIDE for the Linear Burner System PRE-PLANNING GUIDE for the Linear Burner System GAS PRESSURE SPARK products are engineered, safety tested and certified to function properly within a specific gas supply pressure range. It is CRITICALLY

More information

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

GAS-FIRED HIGH INTENSITY INFRARED HEATERS GAS-FIRED HIGH INTENSITY INFRARED HEATERS CATALOG 9-116.1 MARCH, 2003 TABLE OF CONTENTS Modine's MT Series is a gas-fired, high intensity ceramic infrared heater. Ideal for spot heating, the MT series

More information

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE TANKLESS WALL MOUNT LIGHTWEIGHT Constructed of anodized aluminum frame Utilizes the industry s lightest 199,000 BTU high efficiency condensing tankless heater EXPANDABLE Multiple design and installation

More information

U n i t H e at e r s

U n i t H e at e r s Unit Heaters LF Models Enduring performance Allied commercial unit heaters are built to last, season after season Designed and built for durability and peak performance, Allied Commercial unit heaters

More information

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY: INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS (CHECK ONE) PROPANE GAS PROJECT: ARCHITECT/ENGINEER: NAME: ADDRESS: NAME: ADDRESS: DATE: CONTRACTOR: SUBMITTED BY: NAME: ADDRESS: EQUIPMENT

More information

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS DELTA LIMITED, TYPE WH - MODELS 399B-899B SUGGESTED SPECIFICATIONS Catalog No.: 3500.97B Effective: 04-01-17 Replaces: 11-15-08 DIVISION 23 52 33.13 FINNED WATER-TUBE WATER HEATERS - GENERAL 1.1 SUMMARY

More information

High efficiency, cast-iron gas boiler

High efficiency, cast-iron gas boiler SENTRY High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler A smarter choice for informed The boiler you choose for your home

More information

C1210ESC Tankless Water Heater

C1210ESC Tankless Water Heater Engineering Submittal Sheet Overview and ertifications L W LOW-LEAD U P US Massachusetts Plumbing Board Approved Engineering Specifications Water heater shall be a Model Therm 1210 ES. Plant shall consist

More information

Commercial Tankless Rack System

Commercial Tankless Rack System TANKLESS FREE STANDING BACK-TO-BACK LIGHTWEIGHT Constructed of sturdy metal frame Utilizes the industry s lightest 199,000 BTU high efficiency condensing tankless heater EXPANDABLE Multiple design and

More information

esfr dry pendent sprinkler Vk502 (k14.0)

esfr dry pendent sprinkler Vk502 (k14.0) Page 1 of 11 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Dry Pendent Sprinkler VK502 is a fast response fusible element type sprinkler designed for use in storage areas subject to freezing

More information

FIREYE FLAME SCANNERS

FIREYE FLAME SCANNERS SC-103 JUNE 7, 2018 48PT1 (Obsolete) FIREYE S 48PT2 INFRARED: 48PT1, 48PT2 and 48PT2-CEX ROD: 69ND1 For UV Self-Check Scanners use SC-101 For Hazardous Locations or NEMA 4X Scanners use SC-106 For Non

More information

Commercial Tankless Rack System

Commercial Tankless Rack System TANKLESS WALL MOUNT LIGHTWEIGHT Constructed of anodized aluminum frame Utilizes the industry s lightest 199,000 BTU high efficiency condensing tankless heater EXPANDABLE Multiple design and installation

More information

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh PRODUCT SPECIFICATIONS GAS UNIT HEATERS / DUCT FURNACES TU T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ Bulletin No. 20402 November 207 Supersedes November 206

More information