INSTALLATION INSTRUCTIONS

Size: px
Start display at page:

Download "INSTALLATION INSTRUCTIONS"

Transcription

1 INSTALLATION INSTRUCTIONS (-)BHK ELECTRIC FURNACE ELECTRIC HEAT WITH OR WITHOUT INDOOR COOLING COIL (-)BHK FAN COIL UNIT WITH OR WITHOUT ELECTRIC HEAT WITH OR WITH OR WITHOUT INDOOR COOLING COIL (-)BHK HEAT PUMP AIR HANDLERS WITH OR WITHOUT ELECTRIC HEAT DO NOT DESTROY PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCE. WARNING Recognize this symbol as an indication of Important Safety Information THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED SERVICE PERSONNEL FOR PROPER INSTALLATION, SET UP AND OPERATION OF THIS UNIT. READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN IMPROPER INSTALLATION, SET UP, SERVICE OR MAINTENANCE POSSIBLY RESULTING IN FIRE, ELECTRICAL SHOCK, PROPERTY DAMAGE, PERSONAL INJURY OR DEATH SUPERSEDES

2 FIGURE 1 MODEL NUMBER EXPLANATION J 208/240V 1PH 60HZ CONTROL DESIGNATION N S EVAPORATOR COIL CODES A = NO FACTORY INSTALLED COIL 1) MOTOR H.P. 2) BLOWER CFM LO/HI SPEED 3) BLOWER WHEEL DIA./WIDTH 4) FILTER SIZE WIDTH/LENGTH 5) OUTDOOR UNIT " A = W/O COIL WITH CASING B = RCGJ-24A1 C = RCGJ-24A2 D = RCHJ-24A1 E = RCHJ-24A2 F = RCHA-24A1 G = RCHA-24A2 1 = RCHL-24A2 1) 1/3 H.P. 2) LO 600 CFM 3) 11.9 X ) X 21 5) -018 X " A = W/O COIL WITH CASING B = RCGJ-36A1 C = RCGJ-36A2 D = RCHJ-36A1 E = RCHJ-36A2 F = RCHA-36A1 G = RCHA-36A2 2 = RCHL-36A1 3 = RCHL-36A2 1) 1/2 H.P. 2) LO 1000 CFM HI 1200 CFM 3) 11.9 X ) X 21 5) -030, " A = W/O COIL WITH CASING B = RCGJ-48A1 C = RCGJ-48A2 D = RCHJ-48A1 E = RCHJ-51A1* F = RCHA-48A1 G = RCHJ-48A2 4 = RCHL-48A1 5 = RCHL-48A2 6 = RCHL-51A1* 1) 1/2 H.P. 2) LO 1400 CFM HI 1600 CFM 3) 11.9 X ) X 21 5) -042, " A = W/O COIL WITH CASING C = RCGJ-60A1 Z = RCGJ-61A1* Y = RCHJ-61A1* H = RCHA-60A1 7 = RCHL-60A1 8 = RCHL-61A1* 1) 3/4 H.P. 2) LO 1800 CFM HI 2000 CFM 3) 11.9 X ) X 21 5)

3 CONTENTS MODEL NUMBER EXPLANATION Contents RECEIVING DIMENSIONS & WEIGHTS GENERAL Unit Configuration Clearances Vertical Upflow Vertical Downflow Horizontal ELECTRICAL WIRING Power Wiring Control Wiring Grounding ECM MOTOR INFORMATION ECM MOTOR INTERFACE CONTROL AND SETTINGS DUCTWORK REFRIGERANT CONNECTIONS Flowcheck Pistons Condensate Drain Tubing DOUBLE-STACKED COIL UNITS AIR FILTER AIRFLOW PERFORMANCE SEQUENCE OF OPERATION Watt Restrictor Defrost Sequence Emergency Heat Room Thermostat Calculating Temperature Rise Calculating BTUH Heating Capacity Calculating Airflow CFM Calculating Correction Factor PRE-START CHECKLIST MAINTENANCE Air Filter Indoor Coil / Drain Pan / Drain Line Blower Motor and Wheel Lubrication Blower Assembly Removal and Replacement Electric Heater Replacement Motor Replacement ECM Control Module Replacement Blower Wheel Replacement REPLACEMENT PARTS ACCESSORIES / KITS / PARTS RECEIVING Immediately upon receipt, all cartons and contents should be inspected for transit damage. Units with damaged cartons should be opened immediately. If damage is found, it should be noted on the delivery papers, and a damage claim filed with the last carrier. After unit has been delivered to job site, remove carton taking care not to damage unit. Check the unit rating plate for unit size, electric heat, coil, voltage, phase, etc. to be sure equipment matches what is required for the job specification. Read the entire instructions before starting the installation. This is particularly important if this is the first installation for this specific model series. 3

4 FIGURE 2 DIMENSIONS AND WEIGHTS -- SINGLE COIL UNITS NOTE: 24 CLEARANCE REQUIRED IN FRONT OF UNIT FOR FILTER AND COIL MAINTENANCE. DIMENSIONAL DATA - FIGURES 2 & 3 4

5 FIGURE 3 DIMENSIONS AND WEIGHTS -- DOUBLE-STACKED UNITS NOTE: 24 CLEARANCE REQUIRED IN FRONT OF UNIT FOR FILTER AND COIL MAINTE- NANCE. COIL CABINET 2 COIL CABINET 1 5

6 GENERAL Improper installation, or installation not made in accordance with the Underwriters Laboratory certification or these instructions, can result in unsatisfactory operation and/or dangerous conditions and are not covered by the unit warranty. PROPOSITION 65: THIS APPLIANCE CONTAINS FIBERGLASS INSULATION. RESPIRABLE PARTI- CLES OF FIBERGLASS ARE KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER. DO NOT, UNDER ANY CIRCUMSTANCES, CON- NECT RETURN DUCTWORK TO ANY OTHER HEAT PRODUCING DEVICE SUCH AS FIREPLACE INSERT, STOVE, ETC. UNAUTHORIZED USE OF SUCH DEVICES MAY RESULT IN FIRE, CARBON MONOXIDE POISONING, EXPLOSION, PERSONAL INJURY OR PROPERTY DAMAGE. WARNING When installing a unit with cooling coil over a finished ceiling and/or living space, installation of an auxiliary drain pan under the entire unit, to avoid damage to ceiling, is recommended. WARNING CAUTION WARNING DISCONNECT ALL POWER TO UNIT BEFORE INSTALLING OR SERVICING. MORE THAN ONE DISCONNECT SWITCH MAY BE REQUIRED TO DE- ENERGIZE THE EQUIPMENT. HAZARDOUS VOLT- AGE CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. WARNING BECAUSE OF POSSIBLE DAMAGE TO EQUIPMENT OR PERSONAL INJURY, INSTALLATION, SERVICE AND MAINTENANCE SHOULD BE PERFORMED BY A TRAINED, QUALIFIED SERVICE PERSON. CONSUMER SERVICE IS RECOMMENDED ONLY FOR FILTER CLEANING/REPLACEMENT. NEVER OPERATE THE UNIT WITH THE ACCESS PANELS REMOVED. FIGURE 4 DIMENSIONS FOR FRONT CONNECT COIL 3 1 /4 C L 15 3 / /4 9 1 /2 7 1 /2 NOTE: FOR W MEASUREMENT, SEE FIGURE 2. C L W DO NOT INSTALL THIS UNIT IN MANUFACTURED (MOBILE) HOMES. IMPROPER INSTALLATION IS MORE LIKELY IN MANUFACTURED HOUSING DUE TO DUCTWORK MATERIAL, SIZE, LOCATION, AND ARRANGEMENT. INSTALLATIONS IN MANUFAC- TURED HOUSING CAN CAUSE A FIRE RESULTING IN PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. EXCEPTION: MANUFACTURED HOUSING INSTAL- LATIONS ARE APPROVED ONLY WITH DOCUMEN- TATION BY A RECOGNIZED INSPECTION AUTHOR- ITY THAT THE INSTALLATION HAS BEEN MADE IN COMPLIANCE WITH THE INSTRUCTIONS AND ALL WARNINGS HAVE BEEN OBSERVED. WARNING (SEE WARNINGS IN REGARD TO DUCTWORK) CAUTION When used on cooling applications, excessive sweating may occur when unit is installed in an unconditioned space. This can result in property damage. Some building codes require extra cabinet insulation and gasketing when unit is installed in attic applications. If installed in an unconditioned space, apply caulking around the power wires, control wires, refrigerant tubing and condensate line where they enter the cabinet. Seal the power wires on the inside where they exit conduit opening. Caulking is required to prevent air leakage into and condensate from forming inside the unit, control box, and on electrical controls. Install the unit in such a way as to allow free access to the coil/filter compartment and blower/control compartment. Install the unit in a level position to ensure proper condensate drainage. Make sure unit is level in both directions within 1/8. Install the unit in accordance with any local code which may apply and the national codes. Latest editions are available from: National Fire Protection Association, Inc., Batterysmarch Park, Quincy, MA These publications are: ANSI/NFPA No. 70-(Latest Edition) National Electrical Code. NFPA90A Installation of Air Conditioning and Ventilating Systems. NFPA90B Installation of warm air heating and air conditioning systems. The equipment has been evaluated in accordance with the Code of Federal Regulations, Chapter XX, Part UNIT CONFIGURATION All units are modular construction allowing installer to disassemble unit into two 17-1/2 high components, coil casing and blower unit, for ease of installation, then reassemble in location. TO DISASSEMBLE: Remove both access panels and remove six screws holding coil casing to blower unit, lift blower unit from coil casing. 6

7 TO REASSEMBLE: To attach coil casing to blower unit, make sure 3/4 flanges on back and sides of return air opening of blower casing are bent along perforated edge to inside of casing. Clearance holes in flange should match up with drive holes on inside of blower casing. Make sure 3/4 flanges on coil casing are bent up (back and 2 sides only) on supply air side of coil casing along perforated edge. Do not bend flange on front of coil casing. Set supply air side of coil casing (3/4 flanges) into return air opening of blower casing. Replace 6 - #8 screws through flange in coil casing, flange in blower casing and into drive holes on inside of blower casing, two screws in back and two screws in each side. Do not overtighten sheet metal screws, they will strip easily if overtightened. IMPORTANT: Configure the unit with the indoor coil casing installed on air inlet (return) side of the blower section. Do not try to configure unit with indoor coil on discharge (supply) side of blower section. CLEARANCES All units are designed for 0 inches clearance to combustible material on all cabinet surfaces. Some units require supply duct clearances and combustible floor bases depending on the heating kw. The following table should be used to determine these requirements: Model Cabinet Size Model Designation kw Units with electric heating kw above that listed in the table require a one inch clearance to combustible material for the first three feet of supply plenum and ductwork. Additionally, if these units are installed downflow, a combustible floor base is required. Units with electric heating kw equal to or less than the values listed in the table do not require supply ductwork clearances or combustible floor bases. Vertical units require clearance on at least one side of the unit for electrical connections. Horizontal units require clearance on either top or bottom for electrical connections. Refrigerant and condensate drain connections are made on the front of the unit. All units require 24 inches free access to the front of the unit for service. These units may be installed in either ventilated or nonventilated spaces. FIGURE 5 ROTATING CIRCUIT BREAKER VERTICAL UPFLOW Electrical connections can be made from either the left or right side of the unit. Refrigerant and condensate drain connections are made on the front of the unit (see Figures 2, 3 & 4). NOTE: Double-stacked model is side connect. If return air is to be ducted, install duct flush with floor. Use fireproof resilient gasket 1/8 to 1/4 in. thick between duct, unit and floor. Set unit on floor over opening. WARNING IF UNIT IS TO BE INSTALLED WITHOUT AN INDOOR COIL, RETURN DUCT OR PLENUM, IT MUST NOT BE INSTALLED DIRECTLY OVER COMBUSTIBLE MATERI- AL. IF INSTALLED WITHOUT AN INDOOR COIL WITH A RETURN DUCT OR PLENUM, THE AIR PLENUM OR DUCT MUST HAVE A SOLID SHEET METAL BOTTOM WITH NO RETURN AIR OPENINGS, REGISTERS OR FLEXIBLE AIR DUCTS LOCATED DIRECTLY UNDER THE UNIT. EXPOSING COMBUSTIBLE MATERIAL TO THE RETURN OPENING OF AN UPFLOW UNIT WITH- OUT AN INDOOR COIL CAN CAUSE A FIRE RESULTING IN PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. VERTICAL DOWNFLOW Conversion to Vertical Downflow: A vertical upflow unit may be converted to vertical downflow. (See Figures 2, 3 & 4) Remove the indoor coil. Rotate unit into the downflow position, with the coil compartment on top and the blower compartment on bottom. NOTE: In the vertical downflow position, the internal filter is no longer in the tooless access position, therefore the coil door must be removed for filter maintenance. Reinstall the indoor coil in its new position (see Figure 5). Rotate the circuit breaker(s) 180 (see instructions for rotating breaker(s) that follow). IMPORTANT: To comply with certification agencies and the National Electric Code, units with circuit breaker(s) on vertical units must have circuit breakers installed so that the breaker switch on position and marking is up and, off position and marking is down. - To turn breaker(s): Rotate one breaker pair (circuit) at a time starting with the one on the right. Loosen both lugs on the load side of the breaker. Wires are bundles with wire ties, one bundle going to the right lug and one bundle going to the left lug. - Using a screwdriver or pencil, lift white plastic tab with hole away from breaker until breaker releases from mounting opening (see Figure 5). - With breaker held in hand, rotate breaker so that on position is up, off position is down with unit in planned vertical mounting position. Insert right wire bundle into top right breaker lug, ensuring all strands of all wires are inserted fully into lug, and no wire insulation is in lug. - Tighten lug as tight as possible while holding circuit breaker. Check wires and make sure each wire is secure and none are loose. Repeat for left wire bundle in left top circuit breaker lug. 7

8 - Replace breaker by inserting breaker mounting tab opposite white pull tab in opening, hook mounting tab over edge in opening. - With screwdriver or pencil, pull white tab with hole away from breaker while setting that side of breaker into opening. When breaker is in place, release tab, locking circuit breaker into location in opening. - Repeat above operation for remaining breaker(s) (if more than one is provided). - Replace single point wiring jumper bar, if it is used, on line side of breaker and tighten securely. - Double check wires and lugs to make sure all are secure and tight. Check to make sure unit wiring to circuit breaker load lugs match that shown on the unit wiring diagram. Electrical connections can be made from either the left or right side of the unit. Refrigerant and condensate drain connections are made on the front of the unit (see Figure 2). RXBB-AA combustible floor base is used for all unit sizes. Unit must be centered on combustible base in the width dimension (14 3 /8 ). WARNING THE RXBB-AA COMBUSTIBLE FLOOR BASE IS REQUIRED WHEN SOME UNITS WITH ELECTRIC HEAT ARE APPLIED DOWNFLOW ON COM- BUSTIBLE FLOORING. FAILURE TO USE THE BASE CAN CAUSE A FIRE RESULTING IN PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. SEE CLEARANCES FOR UNITS REQUIRING A COM- BUSTIBLE FLOOR BASE. WARNING THE FIRST 36 INCHES OF SUPPLY AIR PLENUM AND DUCTWORK MUST BE CONSTRUCTED OF SHEET METAL AS REQUIRED BY NFPA 90B. THE SUPPLY AIR PLENUM OR DUCT MUST HAVE A SOLID SHEET METAL BOTTOM DIRECTLY UNDER THE UNIT WITH NO OPENINGS, REGISTERS OR FLEXIBLE AIR DUCTS LOCATED IN IT. IF FLEXIBLE SUPPLY AIR DUCTS ARE USED THEY MAY BE LOCATED ONLY IN THE VERTICAL WALLS, OF A RECTANGULAR PLENUM, A MINIMUM OF 6 INCH- ES FROM THE SOLID BOTTOM. METAL PLENUM OR DUCT MAY BE CONNECTED TO THE COM- BUSTIBLE FLOOR BASE, IF NOT, IT MUST BE CONNECTED TO THE UNIT SUPPLY DUCT FLANGES SUCH THAT COMBUSTIBLE FLOOR OR OTHER COMBUSTIBLE MATERIAL IS NOT EXPOSED TO THE SUPPLY AIR OPENING FROM THE DOWNFLOW UNIT. EXPOSING COMBUSTIBLE (NON-METAL) MATERIAL TO THE SUPPLY OPEN- ING OF A DOWNFLOW UNIT CAN CAUSE A FIRE RESULTING IN PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. EXCEPTIONS TO DOWNFLOW WARNINGS: INSTALLATIONS ON CONCRETE FLOOR SLAB WITH SUPPLY AIR PLENUM AND DUCTWORK COMPLETELY ENCASED IN NOT LESS THAN 2 INCHES OF CONCRETE (SEE NFPA 90B). INSTALLATIONS OF UNITS WITHOUT ELECTRIC HEATERS. 8

9 HORIZONTAL Units with an H (left-hand air supply) in the airflow direction position in the model number have factory configured evaporator coils for installation in the horizontal position. Conversion to Horizontal: A vertical upflow evaporator coil may be converted to horizontal by removing the indoor coil and installing horizontal drain pan on coil as shown for right hand or left hand air supply. Reinstall coil in unit as shown for right or left hand air supply. See Figures 6 & 7. Conversion in Horizontal Direction: Evaporator coils configured for horizontal left-hand supply can be changed to horizontal right-hand supply by removing the indoor coil and installing the drain pan as shown in Figures 6 & 7 for appropriate air supply direction. CAUTION HORIZONTAL UNITS MUST BE CONFIGURED FOR RIGHT HAND AIR SUPPLY OR LEFT HAND AIR SUP- PLY. HORIZONTAL DRAIN PAN MUST BE LOCATED UNDER INDOOR COIL. FAILURE TO USE THE DRAIN PAN CAN RESULT IN PROPERTY DAMAGE. Horizontal Drain Pan Model RXBD-CB: This drain pan is used on all coil models and fits all unit sizes either right or left hand air supply. Install horizontal drain pan as shown for right hand or left hand supply. Drain pan connections must be toward front of coil (header connection end). Install coil assembly into horizontal pan as shown with coil endplates fitting into V shaped supports in the front and back of the horizontal pan. Mounting tabs on vertical drain pan fit over the air inlet side of the horizontal pan with vertical pan inside horizontal drain pan. Horizontal pan must be under indoor coil when in the installed position. Note primary and auxiliary drain pan positions for horizontal right vs. horizontal left. Drain connection with 3/4 hole must be connected to primary drain. Connection with 3/8 knockout is the secondary drain connection. Electrical connections may be made from the top or bottom of the unit. Refrigerant and condensate drain connections must be made on the front of the unit. (See unit dimensions and horizontal right hand supply and horizontal left hand supply figures.) IMPORTANT: Units cannot be installed horizontally laying on or suspended from the back of the unit. Horizontal units must be supported or suspended from one side or the other when in the horizontal position. Support along the length of the unit, all units installed horizontally. Do not support or suspend unit from both ends without support in the center of the cabinet. If unit is to be supported or suspended from corners, run two reinforcing rails length of unit and support or suspend from reinforcing rails. NOTE: When converting a vertical upflow to horizontal, the foam tape must be removed from both sides of the vertical pan going into the horizontal pan. When converting a horizontal left-hand to horizontal right-hand, the foam tape must be moved to the appropriate location. WARNING THE SUPPLY AIR PLENUM OR DUCT MUST HAVE A SOLID SHEET METAL BOTTOM WITH NO SUP- PLY AIR OPENINGS, REGISTERS OR FLEXIBLE AIR DUCTS LOCATED IN IT FOR THE FIRST 36 INCHES OF HORIZONTAL SURFACE ON UNITS WITH ELECTRIC HEATERS. FAILURE TO OBSERVE SUPPLY PLENUM, DUCT WARNINGS CAN CAUSE A FIRE RESULTING IN PROPERTY DAMAGE, PER- SONAL INJURY OR DEATH. FIGURE 6 INDOOR COIL AND DRAIN PAN SET-UP HORIZONTAL LEFT-HAND AIR SUPPLY FIGURE 7 INDOOR COIL AND DRAIN PAN SET-UP HORIZONTAL RIGHT-HAND AIR SUPPLY I156 I156 9

10 ELECTRICAL WIRING Field wiring must comply with the National Electric Code (C.E.C. in Canada) and any applicable local ordinance. POWER WIRING It is important that proper electrical power is available for connection to the unit model being installed. See the unit nameplate, wiring diagram and electrical data in the installation instructions. If required, install a branch circuit disconnect of adequate size, located within sight of, and readily accessible to the unit. Units with factory installed circuit breaker(s) meet UL and CSA requirements as a service disconnect and should make above requirement for a field installed branch circuit disconnect unnecessary. IMPORTANT: Units may be equipped with one, two, or three 60 amp. circuit breakers. These breaker(s) protect the internal wiring in the event of a short circuit and serve as a disconnect. Circuit breakers installed within the unit do not provide over-current protection of the supply wiring and therefore may be sized larger than the branch circuit protection. Supply circuit power wiring must be 75 C minimum copper conductors only. See electrical data for ampacity, wire size and circuit protector requirement. Supply circuit protective devices may be either fuses or HACR type circuit breakers. Power wiring may be connected to either the right or left side (vertical) top or bottom (horizontal). A 7/8, 1-3/32 dia. concentric knockout is provided for connection of power wiring to unit. If a larger opening is required, dependent upon kw electric heat supplied, pull appropriate size hole required for conduit size being used. Using a conduit hole punch (Greenlee type), center punch using outside cabinet around 7/8 knockout as a template to center punch location and punch desired hole size. Holes may be punched for any size conduit up to a 2 hole for 1-1/2 conduit. Power wiring is connected to either the power terminal block or circuit breaker(s) in unit control compartment. Single phase units above 10.5 kw may be supplied with circuit breaker(s) requiring separate supply circuits. Units come standard with a jumper bar assembly connecting separate circuits into one single supply circuit (excluding 18 kw and 21 kw C voltage units). Jumper bar assemblies are connected to the line side lugs of the circuit breakers. Jumper bar is assembled for left (upflow) cabinet power wiring entrance. To convert to right (upflow) power entrance: Remove jumper cover, remove jumper bar from circuit breakers, remove screw on back holding left lug in upper hole to bar, reassemble lug in lower hole and retighten screw. Use the same procedure to move the right lug to the upper mounting hole. Reassemble jumper bar into circuit breakers and tighten lugs. Jumper bar is now ready for wiring from the opposite side. If a factory supplied jumper bar for single supply circuit is removed from unit to make multiple supply circuits the line side of the individual circuit breakers must be covered with finger safe covers. (See information on accessories for part numbers.) After wiring is complete, make sure finger safe cover(s) are replaced over circuit breaker(s) lugs covering lug where field connections are made. On units with jumper bar, make sure jumper bar cover is replaced and secured in place. Covers provided for jumper bar must have side of cover broken off on the side wiring has been connected so that field supply will clear under appropriate side of cover. Units with circuit breakers must have covers in place to meet requirements as a service disconnect. CONTROL WIRING IMPORTANT: Class 2 low voltage control wire should not be run in conduit with power wiring and must be separated from power wiring, unless class 1 wire of proper voltage rating is used. Low voltage control wiring should be 18 AWG color-coded (105 C minimum). For lengths longer than 100 ft., 16 AWG wire should be used. Control wiring should be routed through 1/2 dia. knockout near power wiring entrance on either left or right side of unit. After opening selected knockout, install bushing (supplied in parts bag) in openings. If control wiring is routed through right side (upflow), it must be routed through extruded holes in lower front of blower housing behind power raceway to the left side of blower housing. If routed through left side (upflow), it should be routed through extruded hole in lower front left blower side. Field control connections are made to terminals extending from left side of control compartment (upflow position). See wiring diagrams attached to indoor and outdoor sections to be connected, control wiring diagram booklet supplied with outdoor heat pump section, or Figures 10 through 15. Do not leave excess field control wiring inside unit, pull excess control wire to outside of unit and provide strain relief for field control wiring on inside of cabinet at point wiring penetrates cabinet. Make sure, after installation, separation of control wiring and power wiring has been maintained. GROUNDING WARNING THE UNIT MUST BE PERMANENTLY GROUNDED. FAIL- URE TO DO SO CAN RESULT IN ELECTRICAL SHOCK CAUSING PERSONAL INJURY OR DEATH. Grounding may be accomplished by grounding metal conduit when installed in accordance with electrical codes to the unit cabinet. Grounding may also be accomplished by attaching ground wire(s) to ground lug(s) provided in the unit wiring compartment. Ground lug(s) are located close to wire entrance on left side of unit (upflow). Lug(s) may be moved to marked locations near wire entrance on right side of unit (upflow), if alternate location is more convenient. Use of multiple supply circuits require grounding of each circuit to lug(s) provided in unit. 10

11 COPPER WIRE SIZE - AWG. (3% VOLTAGE DROP) S U PP L Y W IR E L E N G TH F E E T 200 [61] 150 [46] 100 [30] 50 [15] SUPPLY CIRCUIT AMPACITY NOTE: WIRE BASED ON COPPER CONDUCTORS 75 C MINIMUM RATING. FOR MORE THAN 3 CONDUCTORS IN A RACEWAY OR CABLE, SEE N.E.C. FOR DERATING THE AMPACITY OF EACH CONDUCTOR BLOWER MOTOR ELECTRICAL DATA MODEL SIZE / ELECTRICAL DESIGNATION VOLTAGE PHASE HERTZ HP RPM SPEEDS CIRCUIT AMPS MINIMUM CIRCUIT AMPACITY MAXIMUM CIRCUIT PROTECTOR 17J 208/ / J 208/ / J 208/ / J 208/ / ELECTRIC HEAT ELECTRICAL DATA CONSTANT CFM CONSTANT CFM CONSTANT CFM CONSTANT CFM Model Size/ Electrical (KW) Designation Heater Volts 240V KW PH/HZ Heater No./KW Type Supply Circuit Single Circuit Multiple Circuit Circuit Amps. Minimum Circuit Ampacity Maximum Circuit Protector 17J06 3.7/4.9 1/60 2/2.5 Single Circuit 20.6/ / /30 17J07 5.3/7.0 1/60 2/3.5 Single Circuit 28.3/ / /40 17J11 7.5/10.0 1/60 3/3.3 Single Circuit 38.9/ / /60 21J06 3.7/4.9 1/60 2/2.5 Single Circuit 22.1/ / /35 21J07 5.3/7.0 1/60 2/3.5 Single Circuit 29.8/ / /45 21J11 7.5/10.0 1/60 3/3.3 Single Circuit 40.4/ / / /14.0 4/3.5 Single Circuit 54.8/ / /80 21J14 5.3/7.0 1/60 2/3.5 Multiple Ckt / / /45 5.3/7.0 2/3.5 Multiple Ckt / / /40 24J06 3.7/4.9 1/60 2/2.5 Single Circuit 22.1/ / /35 24J07 5.3/7.0 1/60 2/3.5 Single Circuit 29.8/ / /45 24J11 7.5/10.0 1/60 3/3.3 Single Circuit 40.4/ / / /14.0 4/3.5 Single Circuit 54.8/ / /80 24J14 5.3/7.0 1/60 2/3.5 Multiple Ckt / / /45 5.3/7.0 2/3.5 Multiple Ckt / / / /17.5 5/3.5 Single Circuit 67.8/ / /100 24J18 5.3/7.0 1/60 2/3.5 Multiple Ckt / / /45 7.9/10.5 3/3.5 Multiple Ckt / / /60 25J11 7.5/10.0 1/60 3/3.3 Single Circuit 42.0/ / / /14.0 4/3.5 Single Circuit 56.4/ / /90 25J14 5.3/7.0 1/60 2/3.5 Multiple Ckt / / /45 5.3/7.0 2/3.5 Multiple Ckt / / / /17.5 5/3.5 Single Circuit 69.4/ / /100 25J18 5.3/7.0 1/60 2/3.5 Multiple Ckt / / /45 7.9/10.5 3/3.5 Multiple Ckt / / / /20.0 6/3.3 Single Circuit 78.0/ / /110 25J21 7.5/10.0 1/60 3/3.3 Multiple Ckt / / /60 7.5/10.0 3/3.3 Multiple Ckt / / /50 Supply circuit protective devices may be fuses or "HACR" type circuit breakers. Largest motor load is included in single circuit and circuit 1 multiple circuit. If non-standard fuse size is specified, use next size larger standard fuse size. 11

12 ECM MOTOR INFORMATION The ECM (Brushless permanent magnet) motor used on the blower in this product is programmed to operate over a wide range of external static pressures ( W.C.) with essentially constant air flow (CFM). Motor efficiency on ECM type motors is higher than that of P.S.C. type motors normally used on this type product. See air flow performance data tables. The ECM motor is programmed to provide a soft start and stop. On a call for heat or cool, the motor will gradually ramp up to the field selected blower speed. This eliminates the sudden rush of air and noise normally associated with a P.S.C. type motor. Once the thermostat and blower delay are satisfied, the motor will gradually ramp down as well. IMPORTANT: A zoning system having a bypass damper is allowed with units having ECM blowers only if a freezestat is installed to protect the indoor coil and compressor. IMPORTANT: The A.C. power plug to the blower motor has locking tabs. It has been shown that by applying excessive force to the A.C. cable half of the connector it is possible to force the connector in backwards. It will not seat and click properly but will make connection. If A.C. power is applied with the connector reversed the motor will be immediately destroyed. Do not force power plug into motor connector backwards. NOTE: Because of the harmonic content of the A.C. Line current to the ECM motor a conventional ammeter will not read correct motor amps. Only a true RMS meter will give accurate AMP readings. IMPORTANT: The flexibility of ECM motors and the fact that this flexibility is contained in programmed memory, not hardware, emphasizes the need for exact motor numbers for replacement motors. Because they all look the same, ECM MOTORS FROM DIFFERENT PRODUCTS OR DIFFER- ENT MODELS OF THE SAME PRODUCT MUST NOT BE INTERCHANGED. IMPORTANT: If a ECM motor is replaced, for proper motor cooling, it is important that the motor be mounted as the original, as far into the blower wheel as practical. IMPORTANT: The ECM motor is controlled directly from the room thermostat (no blower relay). In cooling or heat pump heating, the motor is controlled from the thermostat Y terminal. When the Y or R thermostat circuit is opened a 60 second delay will occur before the blower motor will cycle off. In heating with electric heat or aux. electric heat with heat pump the motor is controlled from either the W1, W2 or E terminals from the thermostat. When the W1 to R thermostat circuit is opened, a 2.5-minute delay will occur before the blower will cycle off. When the G to R thermostat circuit is opened for low speed blower, there is no off delay. For high-speed blower there is a 60-second delay. All thermostat sub-base combinations as recommended and provided through the Parts Department have been tested and are compatible with the ECM motor used in this equipment. Some thermostats may not be compatible with the ECM motor provided in this unit. With thermostat in off state, the voltage on control lines G, Y, W or W2 with respect to 24 vac common should be less than half of the actual measured value of the 24 vac supply. If the measured voltage is too high, thermostat is incompatible with the ECM motor and will cause the motor to run when it should be off. IMPORTANT: RXMD-CO2 accessory blower time delay. Blower time delay is programmed into the ECM motor as standard. Do not use RXMD-C02 blower timer delay on air handlers using ECM motors. TROUBLESHOOTING ECM MOTOR MOTOR RUNS WHEN IT SHOULD BE OFF See above thermostat compatibility with ECM note normal 60 second cooling and 2.5 minute heating delays described above. MOTOR DOES NOT RUN Verify that blower wheel is free and properly tightened on the shaft. Verify line voltage on power connector at motor. Be sure all connectors are properly seated. Do not force the power connector. It should snap easily when correctly positioned. Put thermostat in continuous fan mode. If motor does not run, verify 24 vac on the G to common lines at motor connector. MOTOR OPERATION IS INTERMITTENT Check motor to be sure no water is dripping on or running into it. Verify motor mounting orientation. The wire connectors on motor shell should point straight to the front of the unit. Verify proper drip loops in motor connector cables - If water is found correct source problem. Verify all connectors are firmly seated. Gently pull motor connector wires (both ends of cables) individually to be sure they are properly crimped into housings. MOTOR HESITATES WHEN STARTING This is normal operation while the motor is verifying proper rotation direction. ECM MOTOR INTERFACE CONTROL AND SETTINGS The (-)BHK series air handlers have ECM blower motors, which deliver a constant level of airflow over a wide range of external static pressures (up to 1.0" W.C.). The interface control board provides the required communications between the thermostat and the ECM blower motor. There is a bank of 6 dip switches on the interface board that define the operation of the ECM motor. Switch functions are: Switch Function 1 Nominal Airflow 2 & 3 Latent/Sensible Airflow Adjustments 4 Continuous Airflow 5 & 6 On-Demand Dehumidification Refer to Figure 9 for switch identification and factory default settings. IMPORTANT: Disconnect power to air handler when changing dip switch positions. Even if blower is not operating, the motor will not recognize changes in dip switch positions until unit power is removed and then restored. NOMINAL AIRFLOW ADJUSTMENT The blower motor is programmed to provide cooling airflows of to 5 tons at 400cfm/ton, depending on air handler size. Air handlers are shipped from the factory set for maximum cooling airflow. Switch 1 is used to adjust airflow for the particular system in use. 12

13 g CABINET WIDTH SWITCH 1 POSITION TONNAGE CFM ON OFF ON OFF ON OFF ON OFF Refer to Figure 9 for switch position to achieve the desired airflow. COOLING AIRFLOW ADJUSTMENTS Cooling airflow may be adjusted +10% or -10% from nominal airflow using switches 2 & 3. COOLING SWITCH 2 SWITCH 3 AIRFLOW POSITION POSITION ADJUSTMENT OFF OFF NONE ON OFF 10% OFF ON -10% ONE ON NONE Refer to Figure 9 for switch positions to achieve the desired adjustments in airflow. NOTE: Heating airflow is not affected by switch 2 & 3 positions. NOTE: If the nominal airflow is adjusted +/-10% with switches 2 & 3, the continuous fan speed is adjusted by the same amount. Example: If the nominal airflow is increased by 10%, the continuous fan airflow is increased 10%. CONTINUOUS FAN ADJUSTMENTS Continuous fan may be set to low or high airflow with switch 4. Low airflow is 50% of nominal airflow. High airflow is equivalent to 100% nominal airflow. SWITCH 4 POSITION OFF ON CONTINIOUS FAN AIRFLOW 50% NOMINAL 100% NOMINAL Refer to Figure 9 for switch 4 settings. NOTE: Only use switch 4 if no nominal airflow adjustments are needed. IMPORTANT: If switch 4 is set to the ON position, nominal airflow adjustments and On Demand Dehumidification adjustments will not function regardless of their dip switch settings. j COOLING MODE DEHUMIDIFICATION The first optional 24-volt AC-only input to the interface control board is the On Demand Dehumidification, ODD, terminal input. The ODD terminal input allows the user to have automatic dehumidification in the cooling mode that is controlled by the user s humidistat setting. When the humidity exceeds the humidistat setting, the airflow will be decreased by 15%. This results in higher latent capacity and increases the level of comfort. An Explanation of On Demand Dehumidification Terminal Use The interface control board ODD terminal input is designed to be used with a traditional humidistat. For proper operation, the humidistat must conform to these conditions: INDOOR AMBIENT CONDITION HIGH HUMIDITY LOW HUMIDITY p p p, INPUT TO "ODD" TERMINAL (FROM HUMIDISTAT) NONE 24V AC IMPORTANT: Dehumidistats are not compatible with the interface control board. Typical dehumidistats apply a 24V signal when humidity is high and are incompatible with the interface control board. ON DEMAND DEHUMIDIFICATION AIRFLOW ADJUSTMENT On Demand Dehumidification cooling airflow may be reduced by 15% of nominal airflow using switches 5 & 6. Airflow adjustment available are defined in the following table: SWITCH 5 SWITCH 6 COOLING AIRFLOW SELECTION POSITION POSITION ADJUSTMENT A OFF OFF B ON OFF 15% LESS COOLING AIRFLOW NONE (FACTORY SETTING) C OFF ON ON DEMAND (WHEN USED WITH HUMIDISTAT) D ON ON NONE Selection A gives a 15% reduction in nominal airflow WITHOUT the use of a humidistat. Nominal cooling airflow is reduced 15% whenever the unit is in cooling mode. Example: On a 2.5-ton system, selection A reduces nominal airflow from 1000cfm to 850cfm whenever the system is in cooling. Selection B is the factory setting and does not affect nominal airflow. Selection C allows On Demand Dehumidification when using a humidistat. Nominal airflow is reduced by 15% when the humidistat senses high humidity in the conditioned space. Example: On a 2.5-ton system, selection C reduces nominal airflow from 1000 cfm to 850 cfm when the system is in cooling and the humidistat is calling for On Demand Dehumidification. Selection D does not affect nominal airflow. 13

14 SWITCH 2 POSITION EFFECT OF SWITCHES 2 & 3 ON NOMINAL AIRFLOW EFFECT OF SWITCHES 5 & 6 ON NOMINAL AIRFLOW RESULT: ACTUAL REDUCTION IN NOMINAL AIRFLOW SWITCH 3 POSITION SWITCH 5 POSITION SWITCH 6 POSITION ON OFF +10% OFF OFF -15% -7% OFF ON -10% OFF OFF -15% -15% ON OFF +10% OFF ON -15% * -7% OFF ON -10% OFF ON -15% * -15% *15% reduction in airflow when ODD is used with a humidstat. Note the total reduction in nominal airflow is limited to 15%. On Demand Dehumidification switch settings (5 & 6) do interact with cooling airflow adjustment switch settings (2 & 3). Combining airflow adjustments between these two features may produce unexpected results. The following table defines these interactions: CONTROLLING HUMIDITY WITH A TWO- STAGE COOLING THERMOSTAT It is possible to control humidity with a 2-stage cooling thermostat. Set dip switch 5 OFF and switch 6 ON (position C as defined in Figure 9). This feature will allow the blower speed to be reduced by 15% for the first stage of cooling. Once the thermostat requires more cooling capacity the second stage will be activated and the blower will then go to 100% cooling speed. Once second stage drops out the blower speed will be reduced again. To set this feature, set the dip switches for humidistat control (selection C as defined in Figure 9). A humidistat can also work in parallel with this new feature. Refer to Figures 10 through 15 for typical wiring schematic using this feature. The ODD wiring is shown as the dashed line in the figure. NOTE: Do not use humidistat and a two-stage cooling system together using the above wiring scheme for dehumidification. NOTE: The On Demand Dehumidification feature is ONLY available in the cooling mode. CONTROL BOARD SETTINGS IN THE HEATING MODE The second optional 24-volt AC only input to the interface control board is the B terminal input. The B terminal input is provided for heat pump applications and allows a heat pump thermostat to tell a heat pump to switch its reversing valve to heat mode. Refer to Figure 8 for the interface control board low voltage connections. When B receives a 24-volt signal, all airflow adjustment switches (2, 3, & 4) and cooling On Demand Humidification switches (5 & 6) are bypassed. Nominal airflow as defined with switch 1 is maintained throughout the heat mode. This allows the user to define cooling airflow independently of heating airflow and prevents adverse humidity and heat rise effects. NOTE: The B terminal must be used on heat pumps with auxiliary resistance heat or heat pumps with auxiliary gas heat. NOTE: The B terminal is not used in resistance heat-only systems. TYPICAL SYSTEM CONTROL WIRING The (-)BHK series of air handlers can be used in cooling-only systems or in heat pump applications. The following diagrams illustrate typical system control wiring: Cooling-only Systems: Figure 10: Single-stage cooling-only system with electric heat using a single-stage cooling thermostat Figure 11: Single-stage cooling-only system with electric heat and a humidistat used for On Demand Dehumidification using a single-stage cooling thermostat Figure 12: Single-stage cooling-only system with electric heat and a two-stage cooling thermostat used for On Demand Dehumidification Heat Pump Systems: Figure 13: Single-stage heat pump with electric heat Figure 14: Single-stage heat pump with electric heat and a humidistat used for On Demand Dehumidification Figure 15: Single-stage heat pump with electric heat and a twostage cooling thermostat used for On Demand Dehumidification 14

15 FIGURE 8 IFC BOARD FIGURE 9 AIRFLOW SETTINGS ON OFF OFF OFF OFF OFF 15

16 FIGURE 10 TYPICAL THERMOSTAT WIRING STRAIGHT COOLING WITH ELECTRIC HEAT Single-Stage A/C Thermostat w G Y C R Air Handler ECM Interface Control Board W2 G Y W1 B ODD C R A/C Outdoor Unit Y C FIGURE 11 STRAIGHT COOLING WITH ELECTRIC HEAT AND USING A HUMIDISTAT FOR DEHUMIDIFICATION Single-Stage A/C Thermostat w G Y C R Humidistat Air Handler ECM Interface Control Board W2 G Y W1 B ODD C R A/C Outdoor Unit Y C FIGURE 12 STRAIGHT COOLING WITH ELECTRIC HEAT USING A TWO-STAGE COOLING THERMOSTAT FOR DEHUMIDIFICATION Air Handler ECM Interface Control Board W2 G Y W1 B ODD C R W Two-Stage A/C Thermostat W2 Y Y2 G C R A/C Outdoor Unit Y C 16

17 FIGURE 13 HEAT PUMP WITH ELECTRIC HEAT Heat Pump Thermostat Air Handler ECM Interface Control Board B Y G W2 E C R W2 G Y W1 B 0DD C R Heat Pump Outdoor Unit Y B C R D Purple FIGURE 14 HEAT PUMP WITH ELECTRIC HEAT AND USING A HUMIDISTAT FOR DEHUMIDIFICATION Air Handler ECM Interface Control Board W1 G Y W1 B ODD C R B Heat Pump Thermostat Y G W2 E C R Humidistat Heat Pump Outdoor Unit Y B C R D Purple FIGURE 15 HEAT PUMP WITH ELECTRIC HEAT USING A TWO-STAGE THERMOSTAT FOR DEHUMIDIFICATION B Two-Stage Heat Pump Thermostat C R Y1 Y2 G W W2 Air Handler ECM Interface Control Board W1 G Y W1 B ODD C R Heat Pump Outdoor Unit Y B C R D Purple 17

18 DUCTWORK Field ductwork must comply with the National Fire Protection Association NFPA 90A, NFPA 90B and any applicable local ordinance. WARNING (SEE SPECIFIC AIRFLOW POSITION FOR ADDITIONAL WARNINGS) UNITS ARE FOR DUCTED APPLICATIONS ONLY. A MINI- MUM OF 36 INCHES OF SUPPLY AIR PLENUM AND DUCTWORK IS REQUIRED. NO SUPPLY AIR OPENINGS, REGISTERS OR FLEXIBLE AIR DUCTS MAY BE LOCATED WITHIN THE FIRST 36 INCHES OF SUPPLY PLENUM AND DUCTWORK ON UNITS WITH ELECTRIC HEATERS. FAIL- URE TO OBSERVE SUPPLY PLENUM/DUCT WARNINGS CAN CAUSE A FIRE RESULTING IN PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Sheet metal ductwork run in unconditioned spaces must be insulated and covered with a vapor barrier. Fibrous ductwork may be used if constructed and installed in accordance with SMACNA Construction Standard on Fibrous Glass Ducts. Ductwork must comply with National Fire Protection Association as tested by U/L Standard 181 for Class I Air Ducts. Check local codes for requirements on ductwork and insulation. Duct system must be designed within the range of external static pressure the unit is designed to operate against. It is important that the system airflow be adequate. Make sure supply and return ductwork, grills, special filters, accessories, etc. are accounted for in total resistance. See airflow performance tables in this manual. Design the duct system in accordance with ACCA Manual D Design for Residential Winter and Summer Air Conditioning and Equipment Selection. Latest editions are available from: ACCA Air Conditioning Contractors of America, th Street, N.W., Washington, D.C If duct system incorporates flexible air duct, be sure pressure drop information (straight length plus all turns) shown in ACCA Manual D is accounted for in system. Supply plenum is attached to the 3/4 duct flanges supplied on the unit around the blower outlet. Flanges are flat for shipping purposes and must be bent up along perforated edge around blower opening. Be sure to bend flanges completely up so they do not interfere with air being discharged from blower. IMPORTANT: Flanges around blower opening for attaching supply duct must be bent up out of blower discharge even if not used so they do not restrict airflow from blower. Supply plenum should be the same size as the flanges provided around the blower outlet. Ideally, it should extend 3 feet from the unit before turning or branching off plenum into duct runs. The plenum forms an extension of the blower housing and minimizes air expansion losses from the blower. Changing the size, shape or length will degrade blower performance. If supply discharges directly into a larger duct or plenum as much as.1 W.C., static pressure will be lost. If 3 feet is not possible, even 6, 12 or 18 inches will help. IMPORTANT: If an elbow is included in the plenum close to the unit, it must not be smaller than the dimensions of the supply duct flange on the unit. Some units with electric heaters require 1 in. clearance to supply plenum and branch ducts to combustible material for the first 3 feet from the unit. See CLEARANCES. A 3/4 return duct flange is supplied on all sides of the air inlet opening of the unit coil casing. If the unit is to be installed without a coil casing (no indoor coil), a 3/4 flange is supplied on the back and sides of the air inlet opening of the blower casing. No flange is provided on the front of the opening to the blower casing. If return duct is attached to the inlet of the blower casing, the front flange of the duct should be run up into the opening or 90 brake made on the front flange to tape to the front of the blower casing. IMPORTANT: The front flange on the return duct if connected to the blower casing must not be screwed into the area where the power wiring is located. Drills or sharp screw points can damage insulation on wires located inside unit. Return duct flanges on blower or coil casing are flat for shipping purposes and must be bent out along perforated edge around opening. Secure the supply and return ductwork to the unit flanges, using proper fasteners for the type of duct used and tape the duct-to-unit joint as required to prevent air leaks. REFRIGERANT CONNECTIONS Keep coil connections sealed until refrigerant connections are to be made. See outdoor unit manual for details on line sizing, tubing installation, evacuation and charging information. To install the refrigerant connections, first install the refrigerant block-off plate (located in the Parts Bag, see Figure 17) around the refrigerant connections. Braze all fittings. When refrigerant lines have cooled, insert the foam gasket (located in the parts bag, see Figure 16) around the refrigerant lines, between the coil and the refrigerant block-off plate. For double-stacked coils, see instructions on page 20. IMPORTANT: The refrigerant block-off plate MUST be installed around the refrigerant connections before brazing. When making braze connections close to outside of cabinet, use a brazing shield to protect cabinet paint from being damaged from torch flame. If the installation is in a tight location, it might be convenient to make some external tubing connections before setting unit in place. IMPORTANT: Install refrigerant tubing so it does not block service access to front of unit. 24 in. clearance is required for filter, coil or blower removal and service access. FIGURE 16 REFRIGERANT BLOCK-OFF PLATE AND FOAM GASKET 18

19 FLOWCHECK PISTONS See outdoor unit installation instructions for correct flowcheck piston sizes and proper piston installation instructions. Indoor coil piston size is indicated by the digits underscored in the indoor coil model number. IMPORTANT: It is important that the proper piston sizes be used dependent on indoor coil, outdoor unit combination and application. CONDENSATE DRAIN TUBING Consult local codes or ordinances for specific requirements that may apply. The coil door is shipped from the factory with the condensate drain knockout attached. Knockout must be removed and the condensate block-off plate (included in parts bag, see Figure 17) must be installed to access the front drain. Vertical units (vertical drain pan) are supplied with a 3/4 female pipe thread primary drain connection and a 3/4 female pipe thread auxiliary drain connection. (See unit dimensions figures for drain locations.) IMPORTANT: All drain connections on vertical drain pans have a plastic web covering opening. Connection(s) used must be broken out before connection(s) are made. Break out only connection(s) to be used. Horizontal units (horizontal drain pan) are supplied with a 3/4 female pipe thread primary drain connection and a 3/4 female pipe thread auxiliary drain connection. (See unit dimensions and position figures for drain locations). IMPORTANT: All horizontal pans have plastic web over the secondary drain connection. Plastic web covering secondary connection must be broken out if used. Secondary connection is lowered by 3/8. Do not get primary and secondary connections interchanged. Removal of door knockouts required for drain connections can be made much easier with the door removed from the cabinet. Install drain lines so they do not block service access to front of unit. 24 in. clearance is required for filter, coil or blower removal and service access. Make sure unit is level or pitched slightly toward primary drain connection so that drain pan will drain completely without water standing in pan. IMPORTANT: 2-6" PVC lengths are provided for making drain connection. When making drain fitting connections to drain pan, use a thin layer of teflon paste, silicone or teflon tape and install hand tight. IMPORTANT: When making drain fitting connections to drain pan, do not over torque. Overtorquing fittings can split pipe connections on drain pan. Do not reduce drain line size less than connection size provided on condensate drain pan. All drain lines must be pitched downward away from the unit a minimum of 1/8 in. per foot of line to ensure proper drainage. Do not connect condensate drain line to a closed or open sewer pipe. Run condensate to an open drain or outdoors. The drain line should be insulated where necessary to prevent sweating and damage due to condensate forming on the outside surface of the line. Make provisions for disconnecting and cleaning of the primary drain line should it become necessary. Install a 2 in. trap in the primary drain line as close to the unit as possible. Make sure that the top of the trap is below connection to the drain pan to allow complete drainage of pan. IMPORTANT: Do not operate unit without a drain trap (see Figure 18). The condensate drain is on the negative side of the blower, therefore, air being pulled in through the condensate line will prevent positive drainage without a proper trap. Auxiliary drain if used should be run to a place where it will be noticeable if it become operational. Occupant should be warned that a problem exists if water should begin running from the auxiliary drain line. Test condensate drain pan and drain line after installation is complete. Pour several quarts of water into drain pan, enough to fill drain trap and line. Check to make sure drain pan is draining completely, no leaks are found in drain line fittings, and water is draining from the termination of the primary drain line. FIGURE 18 CONDENSATE DRAIN TRAP FIGURE 17 CONDENSATE BLOCK-OFF PLATE 19

20 UNITS WITH DOUBLE-STACKED COILS UPFLOW UNIT The unit is shipped from the factory configured for installation in the vertical upflow position (supply air direction up). To ensure proper operation install unit with coils positioned as shown in Figure 19. Coil 1 is one of the two coils installed in series and includes a larger capacity expansion valve. Coil 2 is the second of two and includes a smaller capacity valve. CONVERSION TO DOWNFLOW A vertical upflow unit may be converted to downflow. Remove the evaporator coils, place air handler in downflow position, and reinstall coils 180 degrees clockwise from original position. IMPORTANT: place coils 1 and 2 back into the SAME SLOT they were removed from. Coil 1 must ALWAYS be at the return air end of the cabinet. Rotate the circuit breaker(s) 180 degrees (see instructions for rotating breaker(s)). AIRFLOW PERFORMANCE To determine airflow performance, add static shown in Table 1 for each coil to the external duct static. The external static pressure, indicated in inches of Water Column ( W.C.), available for field duct system will be less than shown in the airflow performance data tables by the amount shown in Table 1. NOTE: this table shows the static pressure drop through one 24.5 wide indoor coil. Units with two coils require adjustment for the additional indoor coil. FIGURE 19 DOUBLE-STACK COIL LOCATIONS CONVERSION TO HORIZONTAL A vertical upflow unit may be converted to horizontal. Remove the indoor coils and install a horizontal drain pan on each coil for right-hand or left-hand air supply, as shown in Figures 5 & 6. IMPORTANT: Use RCGJ-61A1 coil for air conditioning ONLY. DO NOT use this coil for heat pump operation. REFRIGERANT CONNECTIONS All refrigerant connections required to manifold the coils together are shipped loose from the factory. This allows the installer to route the common suction and liquid lines in the direction most suitable to the outdoor unit. See Figure 21. IMPORTANT: Locate the sensing bulbs outside the cabinet on the suction lines in the locations shown in Figure 21. Mount the TXV sensing bulbs with tubing exiting top of the bulb, as shown in Figure 21. CONDENSATE TUBING IMPORTANT: Trap each of the evaporator coils separately. Refer to Figure 19 for proper trapping method. FIGURE 20 DOUBLE-STACK COIL CONNECTIONS SENSING BULB TABLE 1 AIRFLOW FOR DOUBLE-STACKED COILS VAPOR LINE CONNECTION LIQUID LINE CONNECTION CONDENSATE CONNECTION SENSING BULB 20

21 AIR FILTER The unit internal air filter should only be used if the unit is readily accessible for filter cleaning or replacing. If unit is not readily accessible for filter maintenance, a remote filter should be installed in the return air system. If a remote filter is installed, it should be sized for a maximum of 300 feet/min. air velocity for the CFM required.. IMPORTANT: Do not operate system without a filter. A filter is required to protect the coil, blower and internal parts from excessive dirt and dust. See unit position figures for location of filter in unit cabinet and service panel giving access to unit filter. AIRFLOW OPERATING LIMITS Model/Cabinet Size Cooling BTUH x 1, Cooling Tons Nominal Heat Pump or Air Conditioning Maximum Heat/Cool CFM (37.5 CFM/1,000 BTUH) (450 CFM/Ton Nominal) Heat Pump or Air Conditioning Nominal Heat/Cool CFM (33.3 CFM/1,000 BTUH) (400 CFM/Ton Nominal) Heat Pump or Air Conditioning Minimum Heat/Cool CFM (30.0 CFM/1,000 BTUH) (360 CFM/Ton Nominal) Blower Motor Speed* Low High Low High Low High Low High Maximum kw Electric Heating & Minimum Electric Heat CFM Maximum Electric Heat Rise F * BLOWER SPEED DICTATED BY ECM INTERFACE CONTROL BOARD AIRFLOW PERFORMANCE DATA AIRFLOW PERFORMANCE Airflow performance data is based on cooling performance with a dry coil and filter in place. Select airflow performance table for appropriate unit size, voltage and number of electric heaters to be used. Make sure external static applied to unit allows operation within the minimum and maximum limits shown in table below for both cooling and electric heat operation. For optimum blower performance, operate the unit in the.2 to.5 W.C. external static range. Units with coils should be installed with a minimum of.1 W.C. external static range. Units without coils should be applied with a minimum of.2 W.C. external static pressure. In general, the indoor motor dip switches should be set as shown in Figure 9 for the appropriate cooling capacity shown, however, at extremes of external static, voltage and number of heaters the higher or lower dip switches may be necessary or more desirable. Always check for proper dip switch settings as units are shipped from the factory for high speed operation. 21

22 AIRFLOW PERFORMANCE DATA 22

23 SEQUENCE OF OPERATION Cooling (cooling only or heat pump) When the thermostat calls for cooling, the circuit between R, G and Y is completed, causing the blower to energize. This circuit also closes the contactor (CC) in the outdoor unit starting the compressor (COMP) and outdoor fan motor (OFM). Heating (electric heat only) When the thermostat calls for heat, the circuit between R and W 1 is completed, and the heater sequencer (HR 1 ) is energized. A time delay will follow then: The heating elements (HE) and the indoor blower motor (IBM) will come on. Units with a second heater sequencer (HR 2 ) can be connected with the first sequencer (HR 1 ) to W on the thermostat sub-base or connected to a second stage W 2 on the sub-base. W 1 on the furnace board MUST be connected for heating blower operation. Heating (heat pump) When the thermostat calls for heat, the circuits between R and G are completed. Circuit R and B energizes the reversing valve (RV) switching it to the heating position (remains energized as long as system switch is in heat position). Circuit R and Y energizes the contactor (CC) starting the outdoor fan motor (OFM), compressor (COMP), and the indoor blower motor (IBM). If the room temperature should continue to fall, circuit R and W2 is completed by the second-stage heat room thermostat. Circuit R-W2 energizes a heat sequencer (HR1). The completed circuit will energize supplemental electric heat. Units with a second heater sequencer (HR2) can be connected with first sequencer (HR1) to W2 on thermostat or connected to a third heating stage W3 on the thermostat sub-base. A light on the thermostat indicates when supplemental heat is being energized. WATT RESTRICTOR (Heating - Heat Pump) Heat pump air handlers with supplemental electric heat above a specific kw dependent on unit size and total heater kw are equipped with a patented watt restrictor. Models so equipped are Cabinet Model Size -14 with more than 6 kw Cabinet Model Size -17, -21 and -24 with more than 11 kw Watt restrictor (WR) may directly control a heater element in the heater circuit or may be in the control circuit controlling heater sequencer (HR2) indirectly controlling two or three heater elements (HE) (see unit wiring diagram). The watt restrictor (WR) will restrict the amount of supplemental electric heat that can be energized dependent on the heat output of the heat pump (temperature of the air leaving the indoor heat pump coil). Since the heat output of the heat pump is dependent upon the outdoor air temperature, this control performs the same function as a field installed outdoor thermostat,. An additional benefit of the watt restrictor is that it can sense a degradation in heat pump performance due to causes other than outdoor temperature and react accordingly to bring on more supplemental electric heat. DEFROST SEQUENCE For sequence of operation for defrost controls, see outdoor heat pump installation instructions. Supplemental heat during defrost can be provided by connecting the purple (PU) pigtail in the outdoor unit to P on the indoor unit control board. This will complete the circuit between R and W through a set of contacts in the defrost relay (DR) when the outdoor heat pump is in defrost. This circuit, if connected, will temper air being discharged from the indoor unit during defrost. Defrost heat control (DHC) is wired in series in the circuit described above on units where the supplemental heat is more than would be required to offset the defrost cooling capacity. Defrost heat control (DHC) is provided on the same models described above having watt restrictors. When the outdoor unit goes into defrost, the circuit between R and W is completed through a set of contacts on the defrost relay (DR) in series with the contacts on the defrost heat control (DHC). Purple (PU) pigtails on the indoor unit and outdoor units must be connected to make circuit. During defrost, the defrost heat control (DHC) senses the air temperature leaving the indoor unit and cycles the supplemental electric heat to maintain comfort (75 to 85 ) air temperature and prevent objectable cold air during defrost. This limits the electric heat output to the minimum required, to conserve energy and prevent the thermostat from being satisfied with electric heat and preventing completion of the defrost cycle. For most economical operation, if cold air is not of concern during defrost, the purple wire can be left disconnected. Supplemental heat will only be engergized by a call from second stage room thermostat. EMERGENCY HEAT (Heating of Heat Pump) If selector switch on thermostat is set to the emergency heat position, the heat pump will be locked out of the heating circuit, and all heating will be electric heat. Jumper should be placed between W2 and E on the thermostat sub-base so that the electric heat control will transfer to the first stage heat on the thermostat. This will allow the indoor blower to cycle on and off with the electric heat when the fan switch is in the auto position. ROOM THERMOSTAT (ANTICIPATOR SETTING) See instructions with outdoor section, condensing unit or heat pump for recommended room thermostats. On units with one electric heat sequencer (HR1) (see wiring diagram on unit), heat anticipator setting should be.16. On units with two electric heat sequencers (HR1 & HR2) (see wiring diagram on unit), heat anticipator setting should be.32 if both are connected to same stage on thermostat. Setting should be.16 if (HR1 &HR2) are connected to separate stages. The thermostat should be mounted 4 to 5 feet above the floor on an inside wall of the living room or a hallway that has good air circulation from the other rooms being controlled by the thermostat. It is essential that there be free air circulation at the location of the same average temperature as other rooms being controlled. Movement of air should not be obstructed by furniture, doors, draperies, etc. The thermostat should not be mounted where it will be affected by drafts, hot or cold water pipes or air ducts in walls, radiant heat from fireplace, lamps, the sun, T.V. or an outside wall. See instruction sheet packaged with thermostat for mounting and installation instructions. NOTE: Some thermostats, particularly solid-state digital types, contain fixed, non-adjustable heat anticipators and adjustment is not permitted. 23

24 CALCULATING TEMPERATURE RISE The formula for calculating air temperature rise for electric resistance heat is: 3.16 x Watts Temperature Rise F = CFM Where: 3.16 = Constant, CFM = Airflow CALCULATING BTUH HEATING CAPACITY The formula for calculating BTUH heating capacity for electric resistance heat is: BTUH Heating = Watts x Where: 1 kw = 1000 Watts, = Btuh/Watt CALCULATING AIRFLOW CFM The formula for calculating airflow using temperature rise and heating BTUH for units with electric resistance heat is: Heating BTUH CFM = 1.08 x Temp. Rise CALCULATING CORRECTION FACTOR For correction of electric heat output (kw or BTUH) or temperature rise at voltages other than rated voltage multiply by the following correction factor: Applied Voltage 2 Correction Factor = Rated Voltage 2 PRE-START CHECK YES NO YES NO YES NO YES NO YES NO YES NO YES NO YES NO YES NO YES NO YES NO YES NO YES NO Is unit properly located, level, secure and serviceable? Has auxiliary pan been provided under the unit with separate drain? (Units installed above a finished ceiling). Is condensate line properly sized, run, trapped, pitched and tested? Have the supply duct flanges on the unit been turned up? Is ductwork correctly sized, run, taped and insulated? have all cabinet openings and wiring been sealed with caulking? Is the indoor coil flowcheck piston and valve size correct? Is the filter clean, in place and of adequate size? Is the wiring tight, correct and to the wiring diagram? Is the unit properly grounded and protected (fuse)? Is the thermostat heat anticipator been set properly? Is the unit circuit breaker(s) rotated properly on up - off down? Are the unit circuit breaker(s) line lug cover(s) in place? YES NO Are all access panels in place and secure? Refer to outdoor unit installation instructions for system start-up instructions and refrigerant charging instructions. 24

25 MAINTENANCE For continuing high performance, and to minimize possible equipment failure, it is essential that periodic maintenance be performed on this equipment. Consult your local dealer as to the proper frequency of maintenance and the availability of a maintenance contract. IMPORTANT: Before performing any service or maintenance procedures, see WARNINGS listed on page 6 of these installation instructions. WARNING UNITS WITH CIRCUIT BREAKER(S) MEET REQUIRE- MENTS AS A SERVICE DISCONNECT SWITCH, HOW- EVER, IF ACCESS IS REQUIRED TO THE LINE SIDE (COVERED) OF THE CIRCUIT BREAKER, THIS SIDE OF THE BREAKER(S) WILL BE ENERGIZED WITH THE BREAKER(S) DE-ENERGIZED. CONTACT WITH THE LINE SIDE CAN CAUSE ELECTRICAL SHOCK RESULT- ING IN PERSONAL INJURY OR DEATH. AIR FILTER Check the system filter every ninety days or as often as found to be necessary and if obstructed, clean or replace at once. IMPORTANT: Do not operate the system without a filter in place. The filter in the unit is a cleanable type. Clean filter using cold water and allow filter to dry. no oiling or coating of the filter is required or recommended. New filters to replace those supplied in unit are available from your local distributor. TO ACCESS AIR FILTER: 1. Locate thumb screws on filter access door and remove. 2. Remove filter access door by tilting it down from the top. 3. Slide filter out. Internal filter is NOT used in downflow air configuration. INDOOR COIL - DRAIN PAN - DRAIN LINE Inspect the indoor coil once each year for cleanliness and clean as necessary. It is necessary to remove the filter and check the return air side of the coil for debris. Generally, the coil can be easily cleaned when it is dry. If the coil is coated with dirt or lint, blow compressed air or nitrogen through the supply side of the coil fins blowing dirt or lint from the return air side of the coil onto the filter or cardboard placed between filter and coil. Be sure lint and dirt is removed from the filter and return air system. If the coil is coated with oil or grease, clean it with a mild detergent and water solution. Rinse the coil thoroughly with clear water. Be careful not to splash water excessively into unit and system. Inspect the drain pan and condensate drain at the same time the cooling coil is checked. Clean the drain pan and condensate drain by removing any foreign matter from the pan. Flush the pan and drain tube with clear water. If the drain tube is restricted, it can generally be cleaned with high pressure water. Remove the drain line from the unit away from the pan and coil to clear the drain line. IMPORTANT: Do not use caustic household drain cleaners in the condensate pan or near the indoor coil. Drain cleaners will quickly damage the indoor coil. BLOWER MOTOR AND WHEEL Inspect the blower motor and wheel for cleanliness. With the system air filter in place, it should be several years before it would become necessary to clean the blower motor and wheel. If it becomes necessary to remove the blower assembly from the unit, see instructions on removal and disassembly of motor, blower and heater parts. The blower motor and wheel may be cleaned by using a vacuum with a soft brush attachment. Remove grease with a mild solvent such as hot water and detergent. Be careful not to disturb the balance weights (clips) on the blower wheel blades. Do not drop or bend wheel as balance will be affected. LUBRICATION The blower motor sleeve bearings are pre-lubricated by the motor manufacturer and do not have oiling ports. Motor should be run for an indefinite period of time without additional lubrication. BLOWER ASSEMBLY REMOVAL AND REPLACEMENT Removing the blower assembly is not required for normal service and maintenance. Removal is necessary for replacement of components such as motor, blower wheel and electric heater(s). After extended use, removal of the blower assembly may become necessary for a thorough cleaning of the blower motor and wheel. WARNING IF REMOVAL OF THE BLOWER ASSEMBLY IS REQUIRED, ALL DISCONNECT SWITCHES SUPPLYING POWER TO THE AIRHANDLER MUST BE DE-ENER- GIZED AND LOCKED (IF NOT IN SIGHT OF UNIT) SO THE FIELD POWER WIRES CAN BE SAFELY REMOVED FROM THE BLOWER ASSEMBLY. FAILURE TO DO SO CAN CAUSE ELECTRICAL SHOCK RESULTING IN PER- SONAL INJURY OR DEATH. Mark field power supply wiring (for replacement) attached to terminal block or circuit breaker(s) on blower assembly. Remove wiring from terminal block or circuit breaker(s). Mark low voltage control wiring (for replacement) where attached to unit control terminals on left side of blower housing. Remove two screws holding blower assembly to front channel of cabinet and pull blower assembly from cabinet. To replace blower assembly, slide blower assembly into blower deck. Make sure blower assembly engages lances in deck properly. If assembly hangs up, check to make sure top and bottom are lined up in proper locations. 25

26 Slide blower assembly to back of cabinet and make sure it is completely engaged. Replace two screws holding blower assembly to front channel of cabinet. Take care not to strip screws, just snug into place. Replace low voltage control wiring with wire nuts and make sure wiring is to wiring diagram and a good connection has been made. Replace field power wiring to terminal block or circuit breaker(s) on control area of blower assembly. Make sure wires are replaced as they were, check wiring diagram if necessary. Tighten supply power wiring securely to terminals lugs. Make sure wiring is within cabinet and will not interfere with access door. Make sure proper separation between low voltage control wiring and field power wiring has been maintained. Replace blower assembly control access panel before energizing equipment. ELECTRIC HEATER REPLACEMENT With the blower assembly removed, electric heater(s) can be removed and replaced from the blower housing without disturbing the motor or blower wheel. Remove both wires from the heater to be removed and remove three screws from outside of blower wrap holding heater brackets to blower wrap. One screw is located under the control mounting plate and is a little difficult to get at. A 1/4 box end or open end wrench should be used to remove and replace this screw With three screws removed, lift heater element and heater terminals through mounting holes in top of blower wrap. Lift heater from blower wrap and with terminal end of heater headed for blower cut off and to the outside of the blower side, remove heater. To replace the heater element, reverse the above process to replace heater. Make sure bend on heater near terminals end is down in place flush or below outlet flanges on blower assembly. Replace screws in heater brackets and tighten. Make sure terminals on heater are straight with at least 1/2 clearance to control mounting plate and 1/2 clearance to access panel. Use a straight edge across front flanges on blower assembly to check clearance (bend if necessary for proper clearance). Replace wiring, make sure connections are tight and are made in accordance with the unit wiring diagram. MOTOR REPLACEMENT With the blower assembly removed, the indoor blower motor can be removed and replaced using the following procedure: Remove motor leads from the motor high and low voltage plugs. Note the lead locations for ease of re-assembly. Loosen the set screw holding the blower wheel onto the motor shaft. The shaft extends through the blower hub so that a wrench can be used on the extended shaft to break the shaft loose if necessary. Be careful not to damage the shaft. Use a wheel puller on the groove in the hub if necessary. Loosen the bolt holding the wire motor band around the motor shell and pull the motor from the motor mount. Note the motor position in the mount for re-assembly. To re-assemble, insert the motor shaft through the hub in the blower wheel and orient the motor to original position. For proper motor cooling, it is important that the motor be mounted the same as the original, as far into the blower as practical. The dimension from the face of the motor end plate (shaft end) to the first wire on the motor mount band around the shell should be: 1-1/2 for (-)BHK /16 for (-)BHK /16 for (-)BHK /16 for (-)BHK-25 With motor held to above position and motor lead plugs oriented to the original position (the wire connectors on the motor must point straight to the supply air end of the unit and away from the return air [filter] end of the unit). Securely tighten the bolt on the mount band to the motor shell. Turn the motor shaft so that the flat on the shaft is located under blower wheel setscrew, and the blower wheel is centered in the blower housing with the same distance on each side between the inlet venturi and the outside of the blower wheel. Re-assemble the motor wiring (high and low voltage plugs) into the motor. IMPORTANT: DO NOT FORCE POWER PLUG INTO THE MOTOR CONNECTOR BACKWARDS. The A.C. power plug to the motor has locking tabs. It has been proven that by applying excessive force to the A.C. cable half of the connector it is possible to force the connector in backwards. It will not seat and click properly but will make connection. If A.C. power is applied with the connector reversed the motor will be immediately destroyed. 26

27 ECM CONTROL MODULE REPLACEMENT Always take the following steps before replacing the control module on the end of the ECM indoor blower motor. 1. HAVE THE CORRECT REPLACEMENT MODULE. These controls are factory programmed for specific operating modes. Even though they look alike, different modules may have different CFM characteristics. IMPORTANT: USING THE WRONG CONTROL MODULE VOIDS ALL PRODUCT WARRANTIES AND MAY PRO- DUCE UNEXPECTED RESULTS. WARNING ALWAYS HAVE 230 VOLT POWER TURNED OFF TO THE FURNACE BEFORE ATTEMPTING ANY REPLACEMENT OF THE MOTOR OR CONTROL MODULE. FAILURE TO DO SO MAY RESULT IN SERIOUS EQUIPMENT DAM- AGE, PERSONAL INJURY OR DEATH. 2. Turn off power to the equipment. Wait at least 5 minutes after disconnecting AC power before opening the motor. 3. While not necessary, it may prove easier to remove the complete blower assembly from the furnace. Unplug the two cable connectors to the motor. There are latches on each connector. DO NOT PULL ON THE WIRES. TO REMOVE THE 16 PIN PLUG, SQUEEZE THE PIN LATCH. The plugs remove easily when properly released. IMPORTANT: DO NOT USE TOOLS WITH MAGNETIC TIPS TO REMOVE THE ECM MOTOR CONTROLLER. SERIOUS DAMAGE CAN BE DONE TO THE ELECTRON- ICS. 4. Locate the two standard 1/4" hex head bolts on the flat end of the motor control module casting. Remove these bolts from the motor while holding the control module. DO NOT REMOVE TWO SCREWS WITH TORX HEADS. 5. The control module is still connected to the motor by a plug and cable. Carefully rotate the control so as to gain access to the plug on the cable end. Squeeze the release latch and gently pull the plug out of the control module. DO NOT PULL ON THE WIRES. GRIP THE PLUG ONLY. 6. The control module is now completely detached from the motor. Use an ohmmeter to measure the resistance from each motor lead (in the motor plug just removed) to the motor shell. This resistance must be greater than 100K ohms. Always measure to the unpainted motor end plate. If any motor lead fails this test DO NOT INSTALL THE NEW CONTROL MODULE. FIGURE 22 INTERNAL MOTOR PLUG AND SOCKET 7. Verify that the replacement control module is correct. Place the new module next to the motor and carefully insert the plug that was removed in step 5. BE SURE THE PLUG LATCHES. IT SHOULD CLICK INTO PLACE. 8. Install the new control module back on the motor. Carefully engage the alignment pin into the appropriate mating motor hole. 9. Replace the two 1/4" hex head bolts. Tighten the bolts snugly. DO NOT OVER TIGHTEN. IMPORTANT: Before replacing the blower motor assembly, check the installation for any application fault that might have caused the motor or control module to fail. Water damage could show as corrosion on the inside or outside of the casting. If so, run a Moisture Check. 10. Install the blower motor assembly back into the furnace. Follow the manufacturer s suggested procedures. 11. Plug the 16 pin connector into the motor. The plug is keyed. Be sure the connector is properly seated and latched. 12. Plug the 5 pin connector into the motor. The plug is keyed. Be sure the connector is properly seated and latched. OBSERVE THE PROPER ORIENTATION. DO NOT FORCE THE CONNECTOR. It plugs in very easily when properly oriented. CAUTION: REVERSING THIS PLUG CAUSES IMMEDI- ATE FAILURE OF THE CONTROL MODULE. 13. Final installation check. Be sure the motor is installed as follows. a. Set the motor into the blower housing as originally provided from the manufacturer. b. Do not allow the motor mount to cover the motor vent openings. FIGURE 21 ECM MOTOR COMPONENTS FIGURE 23 MOTOR ALIGNMENT PIN 27

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS AIR HANDLERS FEATURING EARTH-FRIENDLY R-410A REFRIGERANT: efrigerant (-)HPL Premium 16 SEER Efficiency! RECOGNIZE THIS SYMBOL AS AN INDICATION OF IMPORTANT SAFETY INFORMATION!

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS AIR HANDLERS FEATURING EARTH-FRIENDLY R-410A REFRIGERANT: (-)HPL Premium 16 SEER Efficiency efrigerant! RECOGNIZE THIS SYMBOL AS AN INDICATION OF IMPORTANT SAFETY INFORMATION!!

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS AIR HANDLERS FEATURING R-22 REFRIGERANT: (-)HLA Efficiency (-)HSA Standard Efficiency FEATURING EARTH-FRIENDLY R-410A REFRIGERANT: (-)HLL Efficiency (-)HSL Standard Efficiency

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS AIR HANDLERS FEATURING EARTH-FRIENDLY R-410A REFRIGERANT: (-)HKL Premium Efficiency efrigerant WARNING! These instructions are intended as an aid to qualified licensed service

More information

INSTALLATION INSTRUCTIONS FOR RCQD COILS

INSTALLATION INSTRUCTIONS FOR RCQD COILS INSTALLATION INSTRUCTIONS FOR RCQD COILS efrigerant! RECOGNIZE THIS SYMBOL AS AN INDICATION OF IMPORTANT SAFETY INFORMATION!! WARNING THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED SERVICE

More information

HIGH EFFICIENCY AIR HANDLER

HIGH EFFICIENCY AIR HANDLER FORM NO. HFJ-544 Supersedes Form No. PTZ-789 HIGH EFFICIENCY AIR HANDLER FB***TS SERIES X-13 (ECM) Motor Efficiencies up to 16 SEER Features Industry Standard R-410A Refrigerant also Suitable for R-22

More information

AIR HANDLERS AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant

AIR HANDLERS AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant FORM NO. H11-527 REV. 5 Supersedes Form No. H11-527 Rev. 4 AIR HANDLERS (Model with Coil) AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant earth friendly

More information

AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT FORM NO. H11-509 REV. 8 Supersedes Form No. H11-509 Rev. 7 AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features 1 1 /2 ton [5 kw] through 5 ton [18 kw] models are always just 35

More information

HIGH EFFICIENCY AIR HANDLER

HIGH EFFICIENCY AIR HANDLER FORM NO. HFJ- Supersedes Form No. PTZ-789 HIGH EFFICIENCY AIR HANDLER Features FH***TTS feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most Rheem outdoor units. Versatile

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FOR RCQD COILS WARNING ISO 9001:2008 92-100105-05-03 SUPERSEDES 92-100105-05-02 TABLE OF CONTENTS Model Number Explanation....................... 2 Unit Specifications..............................

More information

Ruud High Efficiency Air Handler

Ruud High Efficiency Air Handler Air Handlers Ruud High Efficiency Air Handler RBHP- Series X-13 (ECM) Motor Efficiencies up to 16 SEER Industry Standard R-410A Refrigerant also Suitable for R-22 Applications Models featuring Electric

More information

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3 FORM NO. H66- REV. 1 Supersedes Form No. G66-6 Rev. WH1T SERIES Constant Torque (ECM) Efficiencies up to 1 SEER HIGH EFFICIENCY AIR HANDLER Features WH1T feature a Constant Torque motor (ECM) which provides

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FOR CASED/UNCASED COILS FOR GAS AND OIL FURNACES: (-)CFA: featuring R-407C/R-22 Refrigerant (-)CFL: featuring Industry Standard R-410A Refrigerant WARNING! These instructions

More information

Rheem High Efficiency Air Handler

Rheem High Efficiency Air Handler Air Handlers Rheem High Efficiency Air Handler RH1V/RH2V- Series ECM Motor Efficiencies up to 16 SEER Includes an energy efficient ECM Motor, which in most applications, enhances the SEER rating of the

More information

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement. AHF / AHK SERIES AIR HANDLING UNITS INSTALLATION GUIDE GENERAL The AHF / AHK series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION MODULAR AIR HANDLER MODEL: N*AH CONTENTS GENERAL... 1 INSPECTION... 2 REFERENCE... 2 LIMITATIONS... 2 LOCATION... 2 BLOWER/COIL ASSEMBLY UPFLOW AND HORIZONTAL INSTALLATIONS...

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Models EBP EBX EBXX(R -410A) CAUTION Use ONLY factory listed electric heaters. Safety Labeling and Signal Words Danger, Warning and Caution The signal words DANGER, WARNING and

More information

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER FORM NO. HFJ-6 Supersedes Form No. PTZ-789 HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER Features The FH**TTT is EcoNet Enabled: This allows the FH**TTT to directly communicate with the EcoNet Smart

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FCP2400D FCP3000D FCP3600D FCP4200D FCP4800D FCP6000D FCP2400C FCX2400C FCP3000C FCP3600C FCX3600C FCP4200C FCP4800C FCX4800C FCP6000C FCX6000C Require AMF001NHA Accessory No

More information

Rheem High Efficiency Air Handler

Rheem High Efficiency Air Handler Air Handlers Rheem High Efficiency Air Handler RH1V/RH2V- Series ECM Motor Efficiencies up to 16 SEER Includes an energy efficient ECM Motor, which in most applications, enhances the SEER rating of the

More information

Ruud Standard Efficiency Air Handler

Ruud Standard Efficiency Air Handler Air Handlers Ruud Standard Efficiency Air Handler RH1P- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

Ruud Standard Efficiency Air Handler

Ruud Standard Efficiency Air Handler Air Handlers Ruud Standard Efficiency Air Handler RH1P- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW & DOWNFLOW/HORIZONTAL TWO-STAGE SAFETY CONDENSING GAS FURNACES Recognize this symbol as an indication of Important Safety Information IMPORTANT: All manufacturer products

More information

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor Air Handlers Rheem Air Handlers RHML- Series X-13 (ECM) RHML feature GE s new X-13 (ECM) motor which provides enhanced SEER performance with most Rheem outdoor units. 2 ton [7.0 kw] through 5 ton [17.6

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Models FCV3600A FCV4800A FCV6000A Require AMF001NHA Accessory No Heat Kit Contents Use ONL factory listed electric heaters. General Information / Installation... 2 Upflow Installations...

More information

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler Air Handlers Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler RHT- Series Constant Torque (ECM) Efficiencies up to 17 SEER The RHT is EcoNet Enabled: This allows the RHT to directly communicate

More information

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler Air Handlers Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler RHT- Series Constant Torque (ECM) Electronic Expansion Valve (EEV) Efficiencies up to 17 SEER The RHT is EcoNet Enabled: This allows

More information

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

Rheem High Efficiency Modulating EcoNet Enabled Air Handler Air Handlers Series Rheem High Efficiency Modulating EcoNet Enabled Air Handler - Series Constant CFM (ECM) Electronic Expansion Valve (EEV) Efficiencies up to 20.5 SEER The is EcoNet Enabled: This allows

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Models MB08B1500A2 MB12F1900A2 MB16J2200A2 MB20N2600A2 Contents 115 Volt General Information / Installation... 2 Installations... 3 Horizontal Installations... 3 Ductwork Connections...

More information

Rheem Standard Efficiency Air Handler

Rheem Standard Efficiency Air Handler Air Handlers Rheem Standard Efficiency Air Handler RHSL- Series PSC Efficiencies up to 15 SEER Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications.

More information

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES INSTALLATION NUAL MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: GENERAL.............................................. 1 SAFETY................................................ 1 UNIT INSTALLATION.....................................

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 2017 Lennox Industries Inc. Dallas, Texas, USA THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE WARNING This product contains a chemical known to the State of California to cause cancer,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 2011 Lennox Industries Inc. Dallas, Texas, USA WARNING Improper installation, adjustment, alteration, service or maintenance can cause personal injury, loss of life, or damage to property. Installation

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw

More information

INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHX SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHX SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHX SERIES ISO 9001 Certified Quality Management System GENERAL.............................................. 1 SAFETY................................................

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 2016 Lennox Industries Inc. Dallas, Texas, USA THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE WARNING This product contains a chemical known to the State of California to cause cancer,

More information

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS CROWN Boiler Co Santa-Fe Series Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS These instructions must be affixed on or adjacent to the air handler Models: SAC049A20 SAC059A25

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 2012 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS Merit CBX25UH Series Units THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE Improper installation, adjustment, alteration,

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. VARIABLE SPEED ELECTRIC FURNACE INSTALLATION INSTRUCTIONS VARIABLE SPEED ELECTRIC FURNACE SAFETY...1 INSTALLATION REQUIREMENTS...2 Tools and Parts...2 Location Requirements...2 Installation Configurations...3

More information

Installation Instructions

Installation Instructions Installation Instructions Indoor Air Handlers for Systems These instructions are primarily intended to assist qualifi ed individuals experienced in the proper installation of heating and/or air conditioning

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE INSTALLATION INSTRUCTIONS ACBX32CM Units WARNING Improper installation, adjustment, alteration, service or maintenance can cause personal injury, loss of

More information

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor IM-BAH-0662402-18 August 2018 Installation Instructions B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor TABLE OF CONTENTS

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FOR COMBINING TWO GAS OR OIL FURNACES FOR PARALLEL OPERATIONS (HEATING AND AIR CONDITIONING) TO BE INSTALLED BY A QUALIFIED, LICENSED SERVICE PERSON. TO AVOID UNSATISFACTORY OPERATION

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTUCTIONS Models EBV 2-5 Ton Use ONL factory listed electric heaters. Variable Speed Safety Labeling and Signal ords Danger, arning and Caution The signal words DANGE, ANING and CAU- TION

More information

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax AllStyle Coil Company, LP 7037 Brittmore Houston, TX 77041 Phone 713-466-6333 Fax 713-466-6363 April 2005 VL / VLX Series Air Handler VL / VLX Series Air Handlers Installation Operation Maintenance The

More information

AUXILIARY ELECTRIC HEATER KITS FOR 7.5 AND 10 TON COMMERCIAL AIR HANDLERS

AUXILIARY ELECTRIC HEATER KITS FOR 7.5 AND 10 TON COMMERCIAL AIR HANDLERS AUXILIARY ELECTRIC HEATER KITS FOR 7.5 AND 10 TON COMMERCIAL AIR HANDLERS WARNING: THIS ACCESSORY IS TO BE INSTALLED BY A QUALIFIED, LICENSED SERVICE PERSON. TO AVOID UN- SATISFACTORY OPERATION OR DAMAGE

More information

Installation Instructions

Installation Instructions 50ES--A, 50EZ--A, 50VG--A, B, 50VL--A, B, 50VR--A, 50VT--A, B 604D-- --A, 607C-- --A, B, 607E-- --A, 704D-- --A, 707C-- --A, B, 707E-- --A PA3G -- -- A, PH3G -- -- A, PA4G, PH4G PAD3, PHD3, PAD4, PHD4,

More information

INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHP SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHP SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHP SERIES ISO 9001 Certified Quality Management System GENERAL..............................................1 SAFETY................................................1

More information

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS **WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER** Altering the product or replacing parts with non authorized factory parts voids all warranty

More information

INSTALLATION MANUAL SINGLE PIECE VARIABLE SPEED AIR HANDLERS MODELS: AV*(C) SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE VARIABLE SPEED AIR HANDLERS MODELS: AV*(C) SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIECE VARIABLE SPEED AIR HANDLERS MODELS: AV*(C) SERIES ISO 9001 Certified Quality Management System GENERAL..............................................1 SAFETY................................................1

More information

Installation Instructions

Installation Instructions Installation Instructions PAM3 SERIES PACKAGE AIR CONDITIONERS TABLE OF CONTENTS SAFETY LABELING AND SIGNAL WORDS... 2 UNIT DIMENSIONS... 3 SAFE INSTALLATION REQUIREMENTS... 3 LOCATING THE UNIT... 3 CLEARANCES...

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS 536306-UAI-B-1009 Electric Heat Accessory 10, 16, 20, 26, 32, 36 & 52kW For Split-System R-410A Air Handling Units Both Air Conditioners and Heat Pumps 7-1/2, 10,

More information

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2 Service Literature Corp. 0527 L10 Revised May 2011 CB26UH and CBX26UH Series Table of Contents CB26UH CBX26UH Model Number Information................... 2 Specifications / Electrical Data................

More information

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS DEHUMIDIFIERS 506451-01 04/2012 HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) FRONT VIEW (with alternate outlet location

More information

Installation Instructions

Installation Instructions 50ZPB, C, 50ZHB, C, PA3Z ---A, PH3Z ---A, PA4Z, PH4Z, PAJ4,PHJ4,WJA4,WJH4 SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters 5---20 kw For 14 SEER, R---410A Manufactured Home Installation Instructions

More information

Installation Instructions

Installation Instructions 50ES---A, 50EZ---A, 50VL---A, 50VG---A, 50VR---A, 50VT---A, 604D--- ---A, 607C--- ---A, 607E,--- ---A, 704D--- ---A, 707C--- ---A, 707E--- ---A PA3G --- --- A, PH3G --- --- A SMALL PACKAGED PRODUCTS Electric

More information

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS INTRODUCTION Please note that HUD Manufactured Home Construction and Safety Standard Section 3280.714, paragraph (a) and subparagraph

More information

R-410A. Installer s Guide WARNING: 18-GE04D2-5

R-410A. Installer s Guide WARNING: 18-GE04D2-5 18-GE04D2-5 Convertible Variable Speed Air Handlers 2-1/2 5 Ton for R-410A 4TEE3F31A; 4TEE3F37A; 4TEE3F40A; 4TEE3F49A; 4TEE3F65A WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING ALL phases

More information

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR / AHE SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR / AHE SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR / AHE SERIES ISO 9001 Certified Quality Management System GENERAL..............................................1 SAFETY................................................1

More information

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1976-360 (1-02) PP TABLE OF CONTENTS 1. Warnings......................................................

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Electric Heat Sections Used with Blower Coil Units ELECTRIC HEAT SECTIONS 505,084M (0655012-30) 05/15 Supersedes 09/11 Litho U.S.A. NOTICE TO INSTALLER IT IS HIGHLY RECOMMENDED

More information

Installation Instructions

Installation Instructions EHNA Electric Heaters 5-20kW For 60 Hz Small Packaged Products MODELS: PAD3, PHD3, PAD4, PHD4, PAD5, PHD5, WPA3, WPH3 Installation Instructions NOTE: Read the entire instruction manual before starting

More information

Installation Instructions

Installation Instructions Installation Instructions B5BV Series Electric Furnaces For HUD approved installations in manufactured homes and modular homes These instructions are intended to assist qualified individuals experienced

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS EF Electric Furnace

INSTALLATION AND MAINTENANCE INSTRUCTIONS EF Electric Furnace INSTALLATION AND MAINTENANCE INSTRUCTIONS EF Electric Furnace WARNING Improper installation, adjustment, service, or maintenance can cause injury or property damage. Refer to this manual. For assistance

More information

INSTALLATION MANUAL SINGLE PIECE STANDARD ECM AIR HANDLERS MODELS: AHX61 SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE STANDARD ECM AIR HANDLERS MODELS: AHX61 SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIECE STANDARD ECM AIR HANDLERS MODELS: AHX61 SERIES GENERAL.............................................. 1 SAFETY................................................ 1 UNIT INSTALLATION.....................................

More information

INSTALLER S GUIDE WARNING: TWE-IN-2A 18-GE02D1-3. Convertible 1 ½ - 5 Ton Air Handlers WARNING HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

INSTALLER S GUIDE WARNING: TWE-IN-2A 18-GE02D1-3. Convertible 1 ½ - 5 Ton Air Handlers WARNING HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING INSTALLER S GUIDE ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES Model: TWE08P3,0B,FB TWE042P3,0B,FB TWE024P3,0B,FB TWE048P3,0B,FB TWE030P3,0B,FB TWE060P3,0B,FB TWE036P3,0B,FB

More information

Installation Instructions

Installation Instructions Installation Instructions EHMA SERIES ELECTRIC HEATERS FOR PAM3 SERIES PACKAGE AIR CONDITIONERS PHM3 SERIES PACKAGE HEAT PUMPS TABLE OF CONTENTS SAFE INSTALLATION REQUIREMENTS... 2 GENERAL INFORMATION...

More information

CBX32MV (HFC-410A) SERIES UNITS

CBX32MV (HFC-410A) SERIES UNITS Service Literature Corp. 005-L2 Revised November 5, 202 (HFC-40A) SERIES UNITS (icomfort-enabled) NOTICE A thermostat is not included and must be ordered separately. The Lennox icomfort thermostat must

More information

INSTALLATION & OPERATING INSTRUCTIONS FOR CEILING MOUNT AIR HANDLERS AC SERIES

INSTALLATION & OPERATING INSTRUCTIONS FOR CEILING MOUNT AIR HANDLERS AC SERIES C US INSTALLATION & OPERATING INSTRUCTIONS FOR CEILING MOUNT AIR HANDLERS AC SERIES Made in the USA by: Goodman Manufacturing Company, L.P. I0-240B 2550 North Loop West, Suite 400, Houston, TX 77092 www.goodmanmfg.com

More information

Installation Instructions

Installation Instructions HUMBBSFP1016 HUMCCSFP1016 Small Fan Powered Humidifier and Humidistat Installation Instructions! WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death.

More information

MERIT SERIES Up Flow / Horizontal

MERIT SERIES Up Flow / Horizontal A I R H A N D L E R S CB26UH / CBX26UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D A T A Bulletin No. 210429 December 2006 Supersedes November 2006 Nominal Capacity 1.5 to 5 Tons Optional

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION SINGLE PIECE AIR HANDLERS Supersedes: 535.02-N2V (598) 535.02-N2V (199) HEAT PUMP MODELS F+RP / F+FP018 thru 060 and COOLING MODELS F+RC / F+FC024 thru 036 035-14363 GENERAL This

More information

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41 Dryer User manual DV22K6800** DV22K6800-03650A-00_EN (US)_151211.indd 1 2015-12-11 7:15:41 Before installation Read through the following instructions before installing the dryer, and keep this manual

More information

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR SERIES ISO 9001 Certified Quality Management System GENERAL..............................................1 SAFETY................................................1

More information

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHE SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHE SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHE SERIES ISO 9001 Certified Quality Management System GENERAL..............................................1 SAFETY................................................1

More information

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY TABLE OF CONTENTS Warnings...3 Package Contents...3 General Information...3 Supply Ducting And Registers...3 Routing 115 VAC Wiring...5

More information

INSTALLATION INSTRUCTIONS FOR SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP

INSTALLATION INSTRUCTIONS FOR SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP RV Products Division INSTALLATION INSTRUCTIONS FOR 46515 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP TABLE OF CONTENTS 1. Warnings.................................................. 2 2. Component

More information

MODELS B1PA024, 030 AND 036

MODELS B1PA024, 030 AND 036 STELLAR 2000 SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 511.26-N1Y (892) 511.26-N1Y (893) MODELS B1PA024, 030 AND 036 035-11622 GENERAL YORK Model B1PA units are factory assembled heat

More information

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330A755 CONTROL BOX KIT (12 VDC HEAT/COOL) 8530-750 CONTROL BOX KIT (24 VAC COOL ONLY)

More information

SPX SERIES PACKAGED AIR CONDITIONING/HEAT PUMP UNITS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

SPX SERIES PACKAGED AIR CONDITIONING/HEAT PUMP UNITS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS SPX SERIES PACKAGED AIR CONDITIONING/HEAT PUMP UNITS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS **WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER** Altering the product or replacing parts with

More information

F, P Series Multi-Position Air Handler Electric or No Heat, with available 5-Speed High Efficiency ECM Motor

F, P Series Multi-Position Air Handler Electric or No Heat, with available 5-Speed High Efficiency ECM Motor 0658686-56 December 2010 Installation Instructions F, P Series Multi-Position Air Handler Electric or No Heat, with available 5-Speed High Efficiency ECM Motor Table of Contents AIR HANDLER SAFETY 1 INSTALLATION

More information

INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER

INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER TABLE OF CONTENTS 1. Warnings...................................................... 3 2. Component Match-Up...........................................

More information

INSTALLATION INSTRUCTIONS FOR 6536 SERIES TWO TON PACKAGED HEAT PUMP

INSTALLATION INSTRUCTIONS FOR 6536 SERIES TWO TON PACKAGED HEAT PUMP INSTALLATION INSTRUCTIONS FOR 6536 SERIES TWO TON PACKAGED HEAT PUMP TABLE OF CONTENTS 1. Warnings...2 2. Component Match-Up...2 3. Unit Depiction Figures...3 4. Blower Performance Data...5 5. General

More information

40TCQ Vertical Ducted Fan Coil Unit for Variable Refrigerant Flow (VRF) Heat Pump or Heat Recovery System

40TCQ Vertical Ducted Fan Coil Unit for Variable Refrigerant Flow (VRF) Heat Pump or Heat Recovery System 40TCQ024-048 Vertical Ducted Fan Coil Unit for Variable Refrigerant Flow (VRF) Heat Pump or Heat Recovery System Installation Instructions CONTENTS Page SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1,2 INSTALLATION...

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION SINGLE PIECE AIR HANDLERS Supersedes: 535.02-N2V (600) 535.02-N2U (900) HEAT PUMP MODELS F2RP / F2FP018 thru 060 and COOLING MODELS F2RC / F2FC024 thru 036 035-14520-000 Rev. B

More information

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Air Handlers Rheem Air Handler RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Front or Bottom Return with aluminum tube and fin coil Flow Check

More information

Installation Instructions

Installation Instructions Electric Heater Packages Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing and servicing of heating and air conditioning

More information

Installation Instructions

Installation Instructions Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A Manufactured Home Installation Instructions NOTE: The Dual Point Kit can only be installed on

More information

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT RV Products Division INSTALLATION INSTRUCTIONS FOR 8330-5501 MOUNTING KIT 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330B755 CONTROL BOX KIT (12 VDC HEAT/COOL) 8530-750 CONTROL BOX KIT (24 VAC COOL ONLY)

More information

Installation Instructions

Installation Instructions Electric Heater Kit For use with GC Geothermal Heat Pumps KWCEH0101B05 KWCEH0101B10 KWCEH0101B15 KWCEH0101B20 Installation Instructions NOTE: Read the entire instruction manual before starting the installation.

More information

STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: N2Y (795) N2Y (1195)

STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: N2Y (795) N2Y (1195) STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: 535.02-N2Y (795) 535.02-N2Y (1195) HEAT PUMP MODELS F1RP / F1FP018 thru 060 and COOLING MODELS F1RC / F1FC018 thru 036 035-13620

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS C7BA & C7BH Series Split System Indoor Cased Coils INSTALLATION INSTRUCTIONS IMPORTANT It is your responsibility to know this product better than your customer. This includes being able to install the

More information

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW INSTALLATION INSTRUCTIONS RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW 92-106595-01-00 TABLE OF CONTENTS Introduction.......................................

More information

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Air Handlers Ruud Air Handler RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Front or Bottom Return with aluminum tube and fin coil Flow Check

More information

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT H6HK Series Electric Heater Kit INSTALLATION INSTRUCTIONS Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT These instructions are primarily intended to assist qualified individuals

More information

Installer s Guide Convertible Air Handlers 1-1/2 5 Ton

Installer s Guide Convertible Air Handlers 1-1/2 5 Ton Convertible Air Handlers 1-1/2 5 Ton 2/4TEC3F18B1000A 2/4TEC3F24B1000A 2/4TEC3F30B1000A 2/4TEC3F36B1000A WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING ALL phases of this installation must

More information

Electric Heat Accessory Installation Instructions

Electric Heat Accessory Installation Instructions Electric Heat Accessory Installation Instructions EBP, EBX, EBV, EBW FVM, FEM, FSM, FSU WARNING Electrical shock hazard. Installation or repairs made by unqualified persons can result in hazards to you

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS C7BA Series Split System Indoor Cased Coils IMPORTANT ATTENTION INSTALLERS: It is your responsibility to know this product better than your customer. This includes being able

More information

SERVICING S-15 CHECKING CAPACITOR

SERVICING S-15 CHECKING CAPACITOR S-15 CHECKING CAPACITOR The direct drive motors are of the permanent split capacitor design. A run capacitor is wired across the auxiliary and a portion of the main windings. The capacitors primary function

More information