1 Changes for the New Edition Denise Beach Senior Engineer, NFPA NFPA
2 Overview NFPA Substantive Changes TIAs 2017 Edition
3 NFPA Substantive Changes
4 Bulk and Industrial Plants Bulk Plant. A facility that stores LP-Gas in containers of more than 4000 gal water capacity prior to further distribution as a liquid for use at other facilities * Industrial Plant. A facility that stores LP-Gas in containers of more than 4000 gal water capacity for use at the facility or to distribute vapor to other facilities.
5 Bulk and Industrial Plants Bulk Plant and Industrial Plant are modified to eliminate confusion in applying container appurtenance and site security requirements. A Industrial plant includes all facilities that use gas on site, including plants, farms, engine fueling stations, schools, hotels, and other locations. Container appurtenances now determined only by container size, not application. i gal wc and less Greater than 4000 gal wc
6 Cathodic Protection of Piping Underground steel piping larger than 1 in. nominal must be protected by cathodic protection system Cathodic protection optional for piping 1 in. and smaller South Carolina incident Liquid id piping i failure due to corrosion One fatality Aboveground piping constructed of corrosion-resistant resistant material, painted or otherwise protected
7 Tank Heaters New definition added, requirements expanded Tank Heater (Indirect and Direct Types). A device used to apply heat either directly to a portion of the container surface in contact t with LP-Gas liquid id or indirectly by circulating LP-Gas liquid from the container to the device and then back to the container Direct Gas-Fired Tank Heater. A gas-fired device that applies heat directly to the container surface in contact with LP-Gas liquid.
8 Tank Heaters Tank heaters must be approved for the application Tank heaters must be marked with rated input and maximum vaporizing capacity Manufacturer s instructions must clearly indicate use for heating LP-Gas containers Limit it control (unchanged) Electric immersion heaters must automatically shut off if liquid level falls below top of heater Direct gas-fired tank heaters must be removable for tank inspection
9 Tank Heaters Direct gas-fired tank heaters for outdoor, aboveground use only No direct flame impingement on the container Automatic safety shutoff (with manual reset) to stop flow of gas to the heater if the pilot flame is extinguished On containers greater than 1000 gal wc, automatic safety shutoff to stop flow of gas if container becomes empty of liquid
10 LP-Gas Pumps New equipment design requirements Design Pressure. The maximum pressure at which the equipment or system is designed to operate. New and specify equipment design pressure for pump and bypass valve based on maximum differential pressure produced by the pump Installation requirements unchanged
11 Facility Hose a hose permanently installed for the purpose of unloading product from CTMVs in nonmetered service into a bulk plant or industrial plant (formerly 6.18) facility hose or the facility shall be equipped with an emergency discharge control system that t will shut down the flow of LP-Gas caused by complete separation of the facility hose within 20 seconds without the need for human intervention Derived from DOT regs (49 CFR 173) for hose installed on some CTMVs
12 Concrete Pad New definition A foundation consisting of solid concrete or masonry blocks, a placed concrete slab, or a poured concrete foundation. Previously undefined Definition addresses enforcement problems related to (G)
13 Vehicular Barrier Protection Previous language was not consistent Protection against vehicular impact Protect where vehicle traffic expected Protect against physical damage Wide range of interpretations t ti for acceptable protection methods and scenarios New definition and annex material intend to clarify
14 Vehicular Barrier Protection ti * A system or method to provide physical protection for LP-Gas storage areas or installations from vehicular incursion.
15 A There are numerous effective means to provide protection for LP-gas installations from impact by motor vehicles. The system or method selected depends on local conditions with regard to the kinds of traffic that can be reasonably expected and the environment surrounding the location. Examples of such protection include, but are not limited to, the following: (1) Guard rails (2) Steel bollards (3) Raised sidewalks (minimum i of 6 in. in height) h (4) Fencing (5) Ditches (6) Berms (not to exceed 50 percent of the container perimeter) (7) Jersey barriers (8) Parking bumpers (minimum of 6 in. in height) (9) Fencing/gates
16 Vehicular Barrier Protection Requirements made consistent: Underground or mounded containers Liquid dispensers Cylinder exchange cabinets also added prescriptive requirements Concrete-filled steel guard posts Spaced not more than 4 ft apart Set at least 3 ft deep in concrete footing At least 3 ft tall At least 3 ft away from container
17 Leak Check and Pressure Test New requirements added to ensure that outside piping is tested for pressure containment and leakage. Definitions iti and requirements substantially ti extracted from NFPA Leak Check. An operation performed on a gas piping system to verify that the system does not leak Pressure Test. An operation performed to verify the gastight integrity of gas piping following its installation ti or modification.
18 Pressure Test 6.14 After installation or modification Pressure test at normal operating pressure LP-Gas is permitted to be used as the test medium NOTE: NFPA 54 does NOT allow LP-Gas to be used in the pressure test Where branches are installed, only the branch must be pressure tested Where NFPA 54 applies, use NFPA 54
19 Leak Check 6.15 Vapor systems operating at 20 psig or less only Immediately after gas is introduced to a new system or following an interruption in service Sample method Annex L Where NFPA 54 applies, use NFPA 54 Where leakage is indicated, fuel supply must be shutoff until necessary repairs are made
20 Small ASME Tank Location PRV on ASME container less than 125 gal wc cannot discharge in or beneath a building Subject of Successful Appeal (previously 6.3.7) restored which permits only cylinders to be installed under buildings w/ 50% perimeter open to atmosphere New requirement explicit on installation of small ASME containers
21 Automated Cylinder Exchange New requirements section 8.6 Must comply with requirements of 8.4 and 8.5 Electrical equipment inside storage cabinet must be Class I, Div 2. Does not impact electrical l classification of equipment installed near the exchange cabinet Cabinets designed to allow cylinder storage in upright position only
22 Unattended Facilities Facilities that are not attended Remote locations No personnel stationed on site Internal valves and emergency shutoff valves must be closed except when facility is in use Containers used for supplying a process or system exempted Vehicle fuel dispenser locations exempted
23 Miscellaneous Combustible materials shall not accumulate or be stored within 10 ft of a container. Long dry grass or weeds deleted d liquid inlet piping shall be designed to prevent debris from impeding the action of valves Fire extinguisher having a 40-B:C or 80-B:C rating and a minimum capacity of 18 lb dry chemical Consistent with NFPA 10 Distance from storage determined by rating
24 TIAs from 2011 Edition Now permanent parts of the code 4.4 Qualification of Personnel Cathodic Protection of Underground and Mounded Tanks 52111(C (Container construction) ti (I) (Installation) (Periodic testing)
25 Tentative Interim Amendments Issued With the Code
26 Testing ESVs Testing of Emergency Shutoff Valves Committee finalized language in ROC Concern that ROC language could be interpreted to mean that non-mandatory ESVs must be tested TIA added language to clarify that only the required ESVs specified in NFPA 58 must be tested
27 Stationary Engines Chapter 11 scope modified to address only vehicle engine applications Containers for stationary engines relocated to 6.26
28 Tentative Interim Amendments Issued Subsequent to the Code
29 Valves & Appurtenances Restructured Existing (A) and (B) combined into one paragraph (A). Deleted existing (C) so that all containers 4000 gal wc and less are equipped the same regardless of application Existing (D) becomes (B). Existing (D)(3) now applies only to containers greater than 125 gal wc.
30 Valves & Appurtenances Table delete column for gal wc now applies only to containers over 4000 gal wc Existing deleted in its entirety Result renumbered as Chapter 11 updated to reflect new structure and correct cross-references references
31 2017 Edition
32 Schedule 2017 Edition Submittal Public Input: PAPER June 6, 2014 Electronic (e-pi) July 7, 2014 Previously, 4 month period starting at Notice of Intent to Enter Cycle Now, Notice of Intent published immediately after issuance of new edition TC Meeting held no later than Dec 12, 2014 First Draft published by March 6, 2015
33 Denise Beach, NFPA
Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input
of 280 2/6/2015 12:06 PM Public Input No. 1-NFPA 58-2013 [ Global Input ] NOTE: This public input originates from Tentative Interim Amendment 58-14-1 (TIA 1079) issued by the Standards Council on August
More informationDepartment of Public Safety
Terry E. Branstad Governor Kim Reynolds Lt. Governor Department of Public Safety Roxann M. Ryan Commissioner Liquid Propane Informational guide to submitting plans Plans are to be submitted to: State Fire
More informationIowa Propane Gas Association 2011 Training Descriptions
Iowa Propane Gas Association 2011 Training Descriptions CETP Classes Basic Principles & Practices - 2 days The Basic Principles and Practices class is an entry level course designed to provide all individuals
More informationPreliminary Agenda Technical Committee on Liquefied Petroleum Gas
Preliminary Agenda Technical Committee on Liquefied Petroleum Gas Tuesday, March 10; All Day Wednesday, March 11; All Day DRURY PLAZA HOTEL San Antonio Riverwalk 0. Administrative. A. Meeting Schedule.
More informationPublic Safety [661] Chapter 226, Liquefied Petroleum Gas, Amended for Application within the State of Iowa
Public Safety [661] Chapter 226, Liquefied Petroleum Gas, Pursuant to the authority of Iowa Code section 101.1, the State Fire Marshal hereby adopts new Chapter 226, Liquefied Petroleum Gas, Iowa Administrative
More informationTemporary LPG Heat for Construction Sites Information Packet
Temporary LPG Heat for Construction Sites Information Packet Colorado Springs Fire Department Division of the Fire Marshal February 2014 W:\Packets\Haz Mat\IFC2009_Temp_LPG_Heat_For_Construction.doc TEMPORARY
More informationPublic Comment No. 7-NFPA 30A-2013 [ Section No ]
Page 1 of 13 Public Comment No. 7-NFPA 30A-2013 [ Section No. 6.4.2 ] 6.4.2 Additional Proposed Changes Each pump shall have installed on the discharge side a listed leak detection device that will provide
More informationSOUTH CAROLINA LIQUEFIED PETROLEUM GAS PROGRAM (LP-GAS)
SOUTH CAROLINA LIQUEFIED PETROLEUM GAS PROGRAM (LP-GAS) Presented by the Division of Fire & Life Safety Office of State Fire Marshal January March 2013 S. C. Office of State Fire Marshal BASIS FOR PROGRAM
More informationIowa Propane Gas Association 2018 Training Descriptions
Iowa Propane Gas Association 2018 Training Descriptions CETP Classes BASIC PRINCIPLES & PRACTICES OF PROPANE - 2 days Basic Principles and Practices is a prerequisite to the more advanced classes. The
More informationLiquefied Petroleum Gas Facility Written Fire Safety Analysis
Liquefied Petroleum Gas Facility Written Fire Safety Analysis For INDEX Page Introduction 2 Conducting the WFSA 2 WFSA CHECKLIST Section I Facility Information 3 Section II Facility Storage Container Information
More informationLiquefied Petroleum Gas Facility Written Fire Safety Analysis
Liquefied Petroleum Gas Facility Written Fire Safety Analysis For Completed by Facility manager Received by Fire Department/Emergency Response representative Date Date INDEX Page Introduction 2 Conducting
More informationCARBON DIOXIDE SYSTEMS FOR BEVERAGE DISPENSING PERMIT REQUIREMENTS
CARBON DIOXIDE SYSTEMS FOR BEVERAGE DISPENSING PERMIT REQUIREMENTS Town of Brighton Office of the Fire Marshal October 2018 Carbon Dioxide Systems for Beverage Dispensing Requirements Scope The intent
More informationGASEOUS HYDROGEN SYSTEMS
CHAPTER 7 GASEOUS HYDROGEN SYSTEMS SECTION 701 GENERAL 701.1 Scope. The installation of gaseous hydrogen systems shall comply with this chapter and Chapters 30 and 35 of the Fire Compressed gases shall
More informationPage 1 of 37 Public Input No. 1-NFPA 30A-2012 [ New Section after 1.1.2 ] 1.1.3 This code shall not apply to aircraft fuel dispensing facilities. NFPA 30A is commonly referenced, in my opinion, incorrectly,
More informationNorth Liberty Fire Department Permit Application Temporary Storage & Use of LPG
Application Fee: $50.00 Application Date: Permit Information Have you previously applied for this type of permit? Date of previous application: Owner/Applicant Information Applicant s Last Name: Applicant
More informationKoffel Associates, Inc.
NFPA 25: STANDARD FOR THE INSPECTION, TESTING, AND MAINTENANCE OF WATER BASED FIRE PROTECTION SYSTEMS William E. Koffel, P.E., FSFPE President Koffel Associates, Inc. www.koffel.com wkoffel@koffel.com
More information2015 National Fuel Gas Code Summary List of Revisions Updated: 04/24/14
The following list contains a summary of the significant revisions in the 2015 National Fuel Gas Code approved by the National Fuel Gas Code Committee, ANSI ASC Z223 and NFPA 54. PIPING Various Brass REVISED
More informationTemporary LPG Heat for Construction Sites Work At Risk and Inspection Information Packet
Temporary LPG Heat for Construction Sites Work At Risk and Inspection Information Packet Colorado Springs Fire Department Division of the Fire Marshal December 2013 W:\Packets\Haz Mat\IFC2009_Work_At_Risk_Temp_LPG_Heat
More information1 Batterymarch Park, Quincy, MA Phone: Fax: M E M O R A N D U M
National Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: Technical Committee on Industrial and Medical Gases Joanne
More informationRecommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region
Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region The following sections, paragraphs, and sentences of the 2015 International Existing
More information2018 Propane Training
2018 Propane Training This 2018 training packet includes a number of classes and labs that are designed to train your employees on the codes, regulations, safe practices, and proper operations that apply
More informationNew Facilities. Minimum Requirements
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Item Reference Violation General Requirements NFPA 1124-7.1.1 Retail sales of consumer fireworks in both new and existing buildings, structures, and
More informationM E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot
M E M O R A N D U M TO: FROM: NFPA Technical Committee on Building Service and Fire Protection Equipment Gregory Harrington, P.E., Staff Liaison DATE: October 1, 2009 SUBJECT: NFPA 5000 A2011 ROP Letter
More informationSmall LP Gas Jurisdictional Systems. Kim Lapierre Technical Training Manager John Minchew Area Safety Manager West
Small LP Gas Jurisdictional Systems Kim Lapierre Technical Training Manager John Minchew Area Safety Manager West NFPA 58, the Liquefied Petroleum Gas Code standard has been the guidance in the LP Gas/Propane
More informationMEMORANDUM. Subject: NFPA 1124 Proposed Tentative Interim Amendment (TIA) No. 1094
National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Pyrotechnics Elena Carroll,
More informationREPORT OF THE NFPA MOTIONS COMMITTEE* ON FALL 2013 REVISION CYCLE STANDARDS
REPORT OF THE NFPA MOTIONS COMMITTEE* ON FALL 2013 REVISION CYCLE STANDARDS I. Introduction. This is the Motions Committee Report on Standards in the Fall 2013 Revision Cycle. The report identifies Certified
More informationAbove Ground Fuel Tank Requirements
FIRE DEPARTMENT in cooperation with Above Ground Fuel Tank Requirements The purpose of this document is to provide information about general Fire Code requirements for above ground storage within the unincorporated
More informationM E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment
M E M O R A N D U M TO: FROM: NFPA Technical Committee on Building Services and Fire Protection Equipment Linda MacKay DATE: November 10, 2009 SUBJECT: NFPA 5000 A2011 ROP Letter Ballot Final Results The
More informationFACT SHEET 2018 National Fuel Gas Code Summary List of Revisions rev
This fact sheet provides an overview of the significant revisions in the 2015 National Fuel Gas Code approved by the National Fuel Gas Code Committee, ANSI ASC Z223 and NFPA 54. These revisions are published
More informationTechnical Committee on Fluidized Bed Boilers
Technical on Fluidized Bed Boilers AGENDA Web/Teleconference 1. Chair s welcome, call to order, and opening remarks at 1:00 pm EST. 2. Self-Introduction of Members and Guests 3. Approval of Minutes from
More informationObjectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts
Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts Guy R. Colonna, PE Division Manager, NFPA Combustible Dust Symposium Detroit, MI September 20, 2011 1 Objectives
More information2018 National Fuel Gas Code Summary List of Revisions Updated: 7/27/17
The following list contains a summary of the significant revisions in the 2015 National Fuel Gas Code approved by the National Fuel Gas Code Committee, ANSI ASC Z223 and NFPA 54. 1.1.1.1 (B), (C), & (D)
More informationPage 1 of 190 Public Input No. 22-NFPA 55-2013 [ Global Input ] Throughout the document, delete ANSI from ANSI/ASME B31.3. Current Text: (multiple locations) ANSI/ASME B31.3 (found in Subsections: 2.3.2
More informationPage 1 of 15 Second Revision No. 8-NFPA 82-2013 [ Section No. 2.2 ] 2.2 NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471. NFPA 13, Standard for the Installation
More informationCommittee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM
1 of 213 10/20/2016 11:02 AM Committee Input No. 2505-NFPA 72-2016 [ Global Input ] Change the term visible to visual where appropriate Submitter Information Verification Submitter Full Name: SIG-NAS Organization:
More informationSecond Revision No. 20-NFPA [ Section No. 1.4 ] Supplemental Information. Submitter Information Verification. Committee Statement
Second Revision No. 20-NFPA 14-2015 [ Section No. 1.4 ] 1.4* Equivalency. Nothing in this standard is intended to prevent the use of systems, methods, or devices of equivalent or superior quality, strength,
More informationFirst Revision No. 1-NFPA 30A-2015 [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement
of 35 1/21/2016 7:56 AM First Revision No. 1-NFPA 30A-2015 [ Section No. 1.1.3 ] 1.1.3* This code shall not apply to those motor fuel dispensing facilities where only liquefied petroleum gas (LP-Gas),
More informationFire Prevention Coffee Break Training. May 2017
Fire Prevention Coffee Break Training May 2017 Agenda Introduction Submittals - Phelan Changes to NFPA 13 - Phelan Questions and Answers Open Forum Please welcome our S ummer Intern Charlie Poppe Small
More informationCommittee on NFPA 51A
Committee on M E M O R A N D U M TO: FROM: NFPA Technical Committee on Industrial and Medical Gases Patti Mucci, Administrative Assistant DATE: May 6, 2010 SUBJECT: ROC Letter Ballot The ROC letter ballot
More informationFirst Revision No. 3-NFPA 51B-2016 [ New Section after 1.5 ] Submitter Information Verification. Committee Statement 11/18/2016 2:25 PM
of 28 11/18/2016 2:25 PM First Revision No. 3-NFPA 51B-2016 [ New Section after 1.5 ] 1.6 Units and Formulas. 1.6.1 The units of measure in this standard are presented first in U.S. customary units (inch-pound
More informationSlide 2 NFPA 25: 2017
Slide 1 Changes for 2017 NFPA 25 Handbook Supplement 8 contains a table highlighting the significant technical changes to NFPA 25 for the 2017 edition, along with a brief comment regarding the reason for
More informationFirst Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM
of 25 7/30/2015 1:35 PM First Revision No. 49-NFPA 17A-2015 [ Detail ] Make the following change to 5.2.1.10.2: 5.2.1.10.2* The manual actuation device shall clearly identify the hazard protected and provide
More informationCommittee on NFPA 30A
Committee on M E M O R A N D U M TO: FROM: NFPA Technical Committee on Automotive and Marine Service Stations Patti Mucci, Administrative Assistant DATE: February 5, 00 SUBJECT: ROP Letter Ballot The ROP
More information2.07 Permit Application Checklist for Diesel Generators, Diesel Fire Pumps, and Fuel Tanks Serving Generators and Fire Pumps (2016)
2.07 Permit Application Checklist for Diesel Generators, Diesel Fire Pumps, and Fuel Tanks Serving Generators and Fire Pumps (2016) Reference: Documents referenced for this bulletin are as follows: San
More informationSTATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT
STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT The interaction of fire protection systems can be extremely complex. The detection of a fire in a building by an automatic device
More informationCHAPTER 5: EXHAUST SYSTEMS
MOTORS, FANS AND FILTERS 503.1 General. Motors and fans shall be sized to provide the required air movement. Motors in areas that contain flammable vapors or dusts shall be of a type approved for such
More informationChapter 2: Definitions
FLORIDA BUILDING CODE Existing Buildings 6 TH Edition (2017) Code Changes based on the document provided by DBPR - 2014 and 6th Edition (2017) Florida Building Code Comparison JUMP TO CHAPTER (click chapter
More informationSecond Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement
1 of 7 3/4/2016 12:02 PM Second Revision No. 5-NFPA 56-2016 [ Section No. 1.1.2 ] 1.1.2 Nonapplication of Standard. This standard shall not apply to the following items: (1)* Piping systems covered by
More informationElectrical Hazards and NFPA-70E: Protecting Your Employees
Electrical Hazards and NFPA-70E: Protecting Your Employees Presented By Mark B. Haskins, MS, CSP Practical Safety Solutions, LLC At the CBIA Safety Health and Wellness Conference May 22, 2014 PRESENTATION
More informationSubject: BSR Uniform Mechanical Code, 2015 Edition: Appeal on Proposal #333
Paul Cabot Administrator National Fuel Gas Ms. Gabriella Davis Recording Secretary, IAPMO Standards Council International Association of Plumbing and Mechanical Officials (IAPMO) IAPMO Group World Headquarters
More informationPublic Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ]
8 of 93 11/6/2015 7:41 AM Public Input No. 52-NFPA 30-2015 [ Section No. 21.2 [Excluding any Sub-Sections] ] For the purpose of this chapter, the term in this section shall have the definitions given.
More informationMEMORANDUM. NFPA Technical Committee on Fire Code (FCC-AAA) Subject: NFPA 1 Proposed Tentative Interim Amendment (TIA) No.1045
National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Fire Code (FCC-AAA) Gregory
More informationFirst Revision No. 106-NFPA [ Chapter NFPA ] Submitter Information Verification. Committee Statement and Meeting Notes
First Revision No. 106-NFPA 86-2012 [ Chapter NFPA ] 7.4.10.2* The number of safety shutoff valve cycles shall be determined by one of the following ways: (1) Counting of actual safety shutoff valve open-closed
More informationPublic Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document
of 79 1/27/2016 2:09 PM Public Input No. 1-NFPA 59-2015 [ Global Input ] Throughout standard remove references to the following and replace with the following: (1) ANSI/API and replace with API. (2) ANSI/UL
More informationReport on First Revisions with Statement June 2014 NFPA 101
101 FR6005 SAF-BCF (32.2.1.1.2) Recommendation: 32.2.1.1.2 Where there are sleeping accommodations for more than 16 residents are provided, the occupancy shall be classified as a large facility in accordance
More informationNFPA 72 is in the same cycle as NFPA 80. The extracted text will be updated with a Second Revision during the second draft meeting.
Input No. 7-NFPA 80-2013 [ Section No. 3.3.8 ] 3.3.8 Automatic Fire Detector. A device designed to detect the presence of a fire signature and to initiate action. For the purpose of this standard, automatic
More information2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content
Based on the 2018 International Fire Code, (IFC ) The International Fire Code (IFC ), establishes minimum regulations for fire safety. This handout will identify important changes in the IFC from 2015
More informationFirst Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM
First Revision No. 1-NFPA 1403-2015 [ Section No. 1.2.1 ] 1.2.1 The purpose of this standard shall be to provide a process for conducting live fire training evolutions to ensure that they are conducted
More informationUNIFIED INTERPRETATION OF PROVISIONS OF IMO SAFETY, SECURITY, AND ENVIRONMENT-RELATED CONVENTIONS
E SUB-COMMITTEE ON SHIP SYSTEMS AND EQUIPMENT 5th session Agenda item 12 SSE 5/12/4 4 January 2018 Original: ENGLISH UNIFIED INTERPRETATION OF PROVISIONS OF IMO SAFETY, SECURITY, AND ENVIRONMENT-RELATED
More informationNarrative Reports As Regulated by 780 CMR, Section 903.0
EXHIBIT 20 Narrative Reports As Regulated by 780 CMR, Section 903.0 903.1.1 - FIRE PROTECTION CONSTRUCTION DOCUMENTS a. Basis (methodology) of design for the protection of the occupancy and hazard for
More informationInternational Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures
International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures Please note this is not an all-inclusive list. The type and complexity of your project
More informationChapter 17, Initiating Devices
Chapter 17, Initiating Devices Summary. Chapter 17 was Chapter 5 in NFPA 72-2007. The term authority having jurisdiction is replaced in some sections by the term other governing laws, codes, or standards.
More informationPage 1 of 6 10/19/2016 9:49 AM. Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input
Public Input No. 4-NFPA 111-2016 [ Section No. 1.1.4.1 ] 1.1.4.1 * This standard shall not cover the following: (1) Application of the SEPSS (2) Distribution wiring (3) Systems having total outputs less
More informationMobile Food Units. A definition of mobile food unit added in OFC Rule 2 is as follows:
Technical Bulletin #18-002 February 2018 / 2017 OFC Mobile Food Units Referenced Codes and Standards: OAC 1301:7-7-3(T); OFC 320 OAC 1301:7-7-2(B); OFC 202 OAC 1301:7-7-9(F); OFC 906 NFPA 58 (2014) NFPA
More informationAMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER
AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER The 2016 Denver Building and Fire Code includes the following codes except as amendment herein. 2015 IBC (Building) 2015 IFC (Fire)
More informationNFPA 1124 (2006 Edition) Compliance List. Permanent Store
NFPA 1124 (2006 Edition) Compliance List Permanent Store (Multiple Items) Row Labels 7.1 Applicability 7.1.1 General Requirements: all consumer fireworks shall comply with this chapter unless otherwise
More informationProtection of Rack Stored Exposed Expanded Group A Plastics with ESFR Sprinklers and Vertical Barriers
Protection of Rack Stored Exposed Expanded Group A Plastics with ESFR Sprinklers and Vertical Barriers Suppression, Detection and Signaling Research and Applications Conference SupDet 2015 March 5, 2015
More informationNational Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:
National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM TO: FROM: Correlating Committee on Combustible Dusts Susan
More informationSecond Revision No. 11-NFPA [ Section No. 2.4 ] Submitter Information Verification. Committee Statement
Second Revision No. 11-NFPA 16-2014 [ Section No. 2.4 ] 2.4 References for Extracts in Mandatory Sections. NFPA 11, Standard for Low-, Medium-, and High-Expansion Foam, 2010 2015 edition. NFPA 13, Standard
More informationARTICLE 25. FUEL GAS CODE
ARTICLE 25. Rule 1. Indiana Fuel Gas Code, 2003 Edition (Repealed) (Repealed by Fire Prevention and Building Safety Commission; filed Mar 18, 2008, 2:32 p.m.: 20080423-IR-675070479FRA, eff 90 days after
More informationFirst Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement
of 43 10/20/2015 4:02 PM First Revision No. 2035-NFPA 101-2015 [ Global Input ] To 14.3.4.4.1, add an item (4) to read: (4) Carbon monoxide detectors shall be installed centrally located within occupiable
More informationRiverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)
Riverside County Fire Department Office of the Fire Marshal 2300 Market St., Ste. 150, Riverside, CA 92501 Ph. (951) 955-4777 Fax (951) 955-4886 Technical Policy Title: Plant Processing and Extraction
More informationNFPA 80 Overview January 21, 2016
NFPA 80 Overview January 21, 2016 Kristin Bigda, P.E. Senior Fire Protection Engineer National Fire Protection Association Presenter Kristin Bigda, P.E. Senior Fire Protection Engineer, NFPA Building Fire
More informationFirst Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM
1 of 11 1/18/2016 5:43 PM First Revision No. 2-NFPA 51-2015 [ Global Input ] Throughout standard remove references to the following and replace with the following: (1) CGA C-7 Guide to Precautionary Labelling
More informationFire protection on chemical manufacturing sites
CFPA-E No 18:2008 Fire protection on chemical manufacturing sites FOREWORD The European fire protection associations have decided to produce common guidelines in order to achieve similar interpretation
More informationSecond Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM
1 of 14 6/22/2016 3:15 PM Second Revision No. 1-NFPA 17A-2016 [ Section No. 4.3.3 ] 4.3.3 All discharge nozzles shall be provided with caps or other suitable devices to prevent the entrance of grease vapors,
More informationThroughout standard remove references to the following and replace with the following:
of 105 1/21/2016 7:49 AM Public Input No. 2-NFPA 30A-2015 [ Global Input ] Throughout standard remove references to the following and replace with the following: (1) ANSI/UL and replace with UL. (2) ANSI
More informationAnalysis of Changes for the 5 th Edition (2014) of the Florida Codes
Analysis of Changes for the 5 th Edition (2014) of the Florida Codes Changes to the Florida Building Code, Fuel-Gas This Analysis of Changes for the 5 th Edition (2014) of the Florida Codes is intended
More informationReport on First Revisions with Statement June 2014 NFPA 101
101 FR7040 SAF-MER (36.1.1.4) 36.1.1.4 The provisions of this chapter shall apply to life safety requirements for all new mercantile buildings. Specific requirements shall apply to suboccupancy groups,
More informationNational Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:
National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Hot Work Operations
More informationF. Driveways. Driveways which provide access to off-street parking or loading from public streets shall comply with the following:
Section 20.945.040 General Design Standards for Surface Parking Areas. A. Review Authority. Parking lot design and drainage shall be subject to review and approval of the City Transportation Manager. B.
More informationNFPA 96, 2017 REVIEW SUMMARY
NFPA 96, 2017 REVIEW SUMMARY 1) NFPA 96 REVISION SUMMARY NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations The 2017 edition adds a new normative annex on mobile
More informationFINAL* REPORT OF THE MOTIONS COMMITTEE
FINAL* REPORT OF THE MOTIONS COMMITTEE ON CERTIFIED AMENDING MOTIONS FOR PRESENTATION AT THE 2012 ASSOCIATION TECHNICAL MEETING JUNE 13-14, 2012 LAS VEGAS, NEVADA I. Introduction. This is the second and
More information26 of 128 9/23/2014 9:25 AM
26 of 128 9/23/2014 9:25 AM Second Revision No. 105-NFPA 72-2014 [ Global Comment ] Revise the Annex F figures that include a smoke detector symbol (hexagon with a whisp of smoke) so that the new smoke
More information5.07 Air Replenishment Systems
5.07 Air Replenishment Systems Reference: 2010 SFFC, Section 511.2 Definitions: CERTIFIED COMPRESSOR. A compressor used by a contractor for maintenance and testing of air replenishment systems that is
More informationOklahoma. 265: Incorporated national codes and standards The following national codes and standards are incorporated by reference:
Oklahoma 310:451-1-3. Adopted references The Board of Health hereby incorporates by reference the International Code Council (ICC) 2006 (IBC) Edition International Building Code; the 2007 Edition Standard
More informationM E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.
National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M To: From: NFPA Technical Committee on Helicopter Facilities
More informationMajor Changes to the 2010 National Construction Codes Contractor s Breakfast January 2014
Major Changes to the 2010 National Construction Codes Contractor s Breakfast January 2014 Philip Rizcallah, P. Eng. NRC-IRC Canadian Codes Centre Presented by Stan Dueck CRBO Overview Where are the major
More informationNFPA 1124 (2006 Edition) Compliance List. Permanent Facility
NFPA 1124 (2006 Edition) Compliance List Permanent Facility (Multiple Items) Row Labels 7.1 Applicability 7.1.1 General Requirements: all consumer fireworks shall comply with this chapter unless otherwise
More informationNEW YORK CITY FIRE DEPARTMENT. Notice of Public Hearing and Opportunity to Comment on Proposed Rule
NEW YORK CITY FIRE DEPARTMENT Notice of Public Hearing and Opportunity to Comment on Proposed Rule What are we proposing? The Fire Department is proposing to amend Section 4601-01 of Title 3 of the Rules
More informationPublic Comment No. 2-NFPA [ Section No ]
Public Comment No. 2-NFPA 16-2013 [ Section No. 3.3.6 ] 3.3.6* Foam-Water Sprinkler System. A piping network connected to a source of foam concentrate and to a water supply. The piping network is equipped
More informationConsumer Fireworks Retail Sales (CFRS) Facility Requirements.
Consumer Fireworks Retail Sales (CFRS) Facility Requirements. Site Plan. The site plan for tents shall show the location of the tent on the site and indicate the minimum separation distances required by
More informationMajor Changes Nova Scotia Building Code 2011 Construction and Maintenance Regulatory Change Industry Briefing
Major Changes Nova Scotia Building Code 2011 Construction and Maintenance Regulatory Change Industry Briefing Ted Ross Labour & Advanced Education Gerard Donahoe Labour & Advanced Education Overview Where
More informationMichigan Fireworks. Mike Evans Instructor # 2062 Program approval # A, 1S, 1T
Michigan Fireworks Mike Evans 734.942.3736 Instructor # 2062 Program approval # 17506 1 A, 1S, 1T PA 256 of 2011 Michigan Fireworks Safety Act What We Need To Know We will discuss Documents to be familiar
More informationTechnical Committee on Fluidized Bed Boilers
Technical Committee on Fluidized Bed Boilers AGENDA NFPA Headquarters 1 Batterymarch Park Quincy, MA 02169 1. Chair s welcome, call to order, and opening remarks at 1:00 pm EST. 2. Self-Introduction of
More informationNFPA 45 NFPA 211 NFPA 1600
NFPA 45 NFPA 211 NFPA 1600 Prepared by: William E. Koffel, P.E., FSFPE Expertly Engineering Safety From Fire 1 Objectives Overview of the NFPA process Understand the scope and application of NFPA 45, NFPA
More information2016 California Building Code Adoption OC amendments Summary Title/Subject Justification/Comments Action
OC Ordinance 7-1-12 2016 Code 2013 Code 2016 Adoption OC amendments Summary Title/Subject Justification/Comments Action Adoption of the, International Building Code, California Residential Code, California
More informationChanges to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH)
Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH) The following represents a review of the Life Safety chapter of the new 2018 Joint Commission CAMH manual for
More informationCHAPTER 56 EXPLOSIVES AND FIREWORKS SECTION FIREWORKS 1.4G RETAIL STORAGE, DISPLAY, AND SALE
CHAPTER 56 EXPLOSIVES AND FIREWORKS SECTION 5609 is amended, to read as follows, with the entire section being an addition to the Fire Code: SECTION 5609. FIREWORKS 1.4G RETAIL STORAGE, DISPLAY, AND SALE
More informationRemove the "Exception" text to be consistent with direction provided in the MOS.
of 37 1/11/2017 7:38 AM Public Input No. 9-NFPA 88A-2015 [ Global Input ] Remove the "Exception" text to be consistent with direction provided in the MOS. The current language in 88A has numerous section
More information