Electropneumatic Hot Melt Application Heads EP 34 / EP 34 S / EP 34 SD

Size: px
Start display at page:

Download "Electropneumatic Hot Melt Application Heads EP 34 / EP 34 S / EP 34 SD"

Transcription

1 Electropneumatic Hot Melt Application Heads Manual P/N A English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY

2 Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which is protected by copyright. Original copyright date No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Nordson Corporation. The information contained in this publication is subject to change without notice. Trademarks AccuJet, AquaGuard, Asymtek, Automove, Autotech, Blue Box, CF, CanWorks, Century, Clean Coat, CleanSleeve, CleanSpray, Compumelt, Control Coat, Cross-Cut, Cyclo-Kinetic, Dispensejet, DispenseMate, Durafiber, Durasystem, Easy Coat, Easymove Plus, Econo-Coat, EPREG, ETI, Excel 2000, Flex-O-Coat, FlexiCoat, Flexi-Spray, Flow Sentry, Fluidmove, FoamMelt, FoamMix, Helix, Horizon, Hose Mole, Hot Shot, Hot Stitch, Isocoil, Isocore, Iso-Flo, JR, KB30, Little Squirt, Magnastatic, MEG, Meltex, MicroSet, Millenium, Mini Squirt, Moist-Cure, Mountaingate, MultiScan, Nordson, OmniScan, Opticoat, Package of Values, Pattern View, PluraFoam, Porous Coat, PowderGrid, Powderware, Pro-Flo, ProLink, Pro-Meter, Pro-Stream, PRX, RBX, Rhino, S. design stylized, Saturn, SC5, Select Charge, Select Coat, Select Cure, Slautterback, Smart-Coat, Spray Squirt, Spraymelt, Super Squirt, Sure Coat, System Sentry, Tela-Therm, Trends, Tribomatic, UniScan, UpTime, Veritec, Versa-Coat, Versa-Screen, Versa-Spray, Watermark, When you expect more. are registered trademarks of Nordson Corporation. ATS, Aerocharge, Auto-Flo, AutoScan, BetterBook, Chameleon, CanNeck, Check Mate, COLORMAX, Control Weave, Controlled Fiberization, CPX, E-Nordson, EasyClean, Eclipse, Equi=Bead, Fillmaster, Gluie, Ink-Dot, Iso-Flex, Kinetix, Maxima, MicroFin, Minimeter, Multifil, OptiMix, PluraMix, Primarc, Prism, Process Sentry, PurTech, Pulse Spray, Seal Sentry, Select Series, Sensomatic, Shaftshield, Spectral, Spectrum, Sure Brand, Swirl Coat, Vista, Walcom, 2 Rings (Design) are trademarks of Nordson Corporation. Designations and trademarks stated in this document may be brands that, when used by third parties for their own purposes, could lead to violation of the owners rights. COV_EN_409090A 1998 Nordson Corporation

3 Table of Contents I Table of Contents Safety Decription 1. Intended Use Unintended Use Examples Residual Risks Manual References Illustrations Application Head EP Application Head EP 34 S Application Head EP 34 SD Functioning ID Plate Installation 1. Unpacking Transport Installation Exhausting Adhesive Fumes Storage Disposal Electrical Connection Laying Cable Connecting Application Head Triggering Solenoid Valve Pneumatic Connection Compressed Air Filter (Accessory) Heated Air Assembly (Accessory) Connecting Compressed Air Connecting Spray Air (EP 34 S and EP 34 SD) Lubricating or Not Lubricating the Control Air Nordson Corporation

4 II Table of Contents Installation (contd.) Operation with Non-Lubricated Control Air Operation with Lubricated Control Air Installing Heated Hoses Connecting Disconnecting Relieving Pressure Second Open jawed Wrench Operation 1. Triggering Solenoid Valve Setting Temperatures Maximum Operating Temperature Adjusting Control Air Pressure Maximum Control Air Pressure Setting Adhesive Application Quantity Stem Stroke Adjustment Adjusting Spray Pattern (EP 34 S) Adjusting Spray Pattern (EP 34 SD) Settings Record Maintenance 1. Relieving Pressure Daily Maintenance Inspection for External Damage External Cleaning of Application Head Release coated Application Heads External Cleaning of Nozzle Regular Maintenance Changing Type of Adhesive Maintenance Record Nordson Corporation

5 Table of Contents III Repair/Retrofitting 1. Retrofitting Application Head with New Control Modules Replacing Single Control Modules Removing and Installing Control Module Removing Installing Troubleshooting 1. Troubleshooting Table Specifications 1. General Data Power Cables Nordson Corporation

6 IV Table of Contents 1998 Nordson Corporation

7 Electropneumatic Hot Melt Application Heads 1 Safety WARNING: Please follow the safety regulations enclosed as a separate document and the specific safety notes in the entire documentation. Decription 1. Intended Use EP 34 hot melt application heads hereafter also referred to as application heads may only be used for the application of hot melt materials. Any other use is considered to be unintended. Nordson will not be liable for personal injury or property damage resulting from unintended use. Intended use also includes the observance of Nordson safety instructions. Nordson recommends obtaining detailed information about the materials to be used. Unintended Use Examples The application heads may not be used under the following conditions: In defective condition When modifications or changes have been made by the customer In a potentially explosive atmosphere When hot melt materials not suitable for the unit are used When the values stated under Specifications are not complied with. The application heads may not be used to process the following materials: Polyurethane hot melt material (PUR) Explosive and flammable materials Erosive and corrosive materials Food products Nordson Corporation

8 2 Electropneumatic Hot Melt Application Heads 2. Residual Risks The application head is designed to protect operating personnel from possible risks. However, some residual risks can not be avoided. Personnel must consider the following: Risk of burns on the hot application head: from hot adhesive, when replacing filter cartridges (option) and when making adjustments. Inhalation of potentially hazardous hot melt material vapors. 3. Manual References This manual applies to the entire series. The position numbers in the illustrations do not correspond to the position numbers in the technical drawings and the spare parts lists. The illustrations show only the essential unit components. All other components and details can be found in the enclosed technical drawings (Refer to Parts List) Nordson Corporation

9 Electropneumatic Hot Melt Application Heads 3 4. Illustrations Application Head EP 34 Figure 1 shows the essential components of the application head EP EPAH324L199B0698 Fig Solenoid valve 2. Control air connection 3. Power cable 4. Hose connection (adhesive) 5. Bracket 6. Body 7. Control module 8. Leakage hole 9. Nozzle EP Stem stroke adjustment 1998 Nordson Corporation

10 4 Electropneumatic Hot Melt Application Heads 4. Illustrations (contd.) Application Head EP 34 S Figure 2 shows the essential components of the application head EP 34 S EPAH325L199A1297 Fig Solenoid valve 2. Control air connection 3. Spray air connection 4. Power cable 5. Hose connection (adhesive) 6. Bracket 7. Body 8. Control module 9. Leakage hole 10. Nozzle EP 34 S 11. Stem stroke adjustment 12. Air adjustment screw spray air 1998 Nordson Corporation

11 Electropneumatic Hot Melt Application Heads 5 Application Head EP 34 SD Figure 3 shows the essential components of the application head EP 34 SD A I EPAH326L199A1297 Fig Solenoid valve 2. Control air connection 3. Spray air connection 4. Power cable 5. Hose connection (adhesive) 6. Bracket 7. Body 8. Control module 9. Leakage hole 10. Nozzle EP 34 SD 11. Stem stroke adjustment 12. Air adjustment screw o(uter) spray air 13. Air adjustment screw i(nner) spray air 1998 Nordson Corporation

12 R 6 Electropneumatic Hot Melt Application Heads 5. Functioning The EP 34 application heads are used to apply adhesives as bead application (EP 34), spiral shaped (EP 34 S) or atomization application (EP 34 SD). The control module and body are separate from one another. This enables temperatures of 200 C / 392 F or 260 C / 500 F (high temperature or T version) to be maintained over longer periods of time. The application head is heated with electric heater cartridges. The temperature is monitored continuously by temperature sensors and controlled by an electronic temperature controller located in the electrical cabinet of the application unit. The patented spray method (EP 34 S, EP 34 SD) mixes adhesive with spray air inside of the spray nozzle. ID Plate Nordson Engineering GmbH D Lüneburg Germany 1. box Type of application head 2. box Nordson order number 3. box Serial number 4. box Operating voltage V = Volt 5. box Power consumption W = Watt V W CFSY084S Fig Nordson Corporation

13 Electropneumatic Hot Melt Application Heads 7 Installation WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. 1. Unpacking Unpack carefully, then check for transport damage. Reuse packaging materials or dispose of according to local regulations. 2. Transport NOTE: The hot melt application head is a high precision, valuable part. Handle very carefully! Protect the nozzle from damage. 3. Installation Install the application head in the appropriate place in the coating machine. Observe the following: Do not operate in an explosive atmosphere Protect from humidity, vibrations, dust and drafts Ensure easy access to parts relevant to maintenance and operation Protect nozzle from damage. Exhausting Adhesive Fumes Ensure that adhesive fumes do not exceed the prescribed limits. Suction off adhesive fumes. Ensure sufficient ventilation of the surroundings. 4. Storage Do not store outside! Protect from humidity and dust. Do not lay unit on the nozzle. Protect the nozzle from damage. 5. Disposal When your Nordson product has exhausted its purpose and/or is no longer needed, dispose of it according to local regulations Nordson Corporation

14 8 Electropneumatic Hot Melt Application Heads 6. Electrical Connection WARNING: Risk of electrical shock. Failure to observe may result in personal injury, death, or equipment damage. Laying Cable WARNING: Ensure that cables do not touch rotating and/or hot parts. Do not pinch cables. Check regularly for damage. Replace damaged cables immediately! Connecting Application Head WARNING: Only operate with the voltage shown on the ID plate. 1. Connect power cable with plug (1) to the socket on the heated hose. 2. Use safety clips (when available) to secure the plug connection. 1 EPAH327S061A1297 Fig. 5 Triggering Solenoid Valve WARNING: Only operate with the voltage shown on the ID plate. Trigger the solenoid valve only when the application head is heated to operating temperature! When the adhesive is too cold, seals in the control module can be damaged Nordson Corporation

15 Electropneumatic Hot Melt Application Heads 9 7. Pneumatic Connection The application head may only be connected to pressure controlled and conditioned compressed air. NOTE: The control air must either be lubricated, or it may not be lubricated at all. Read the chapter Lubricating or Not Lubricating the Control Air carefully. The spray air may not be lubricated. Compressed Air Filter (Accessory) Safe operation and lifetime of pneumatically driven application heads essentially depend on conditioning of the compressed air. Dust or condensation will increase the wear on sliding surfaces and sealing elements, thereby causing damage. To avoid these contrary influences, the control air for Nordson application heads must be conditioned by an air filter with air condensate bowls. The air conditioning unit cleans and dries the compressed air. NOTE: The filter mesh size may not exceed 40 m. Heated Air Assembly (Accessory) Nordson heated air assembly kits are used to condition spray air for spray air application heads and guns. They consist of a pressure control valve with filter, a solenoid valve and a fine metering valve. For additional information, refer to the manual Heated Air Assembly. NOTE: The spray air should be heated with an air preheater (accessory). Connecting Compressed Air Connect the control air hose to the air connection (1). 1 NOTE: Ensure that control air is on at all times. Among other functions, it keeps the nozzle closed when EMERGENCY OFF occurs or when the system comes to a standstill. This prevents adhesive from dripping out of the nozzle. EPAH328S061A1297 Fig Nordson Corporation

16 10 Electropneumatic Hot Melt Application Heads 7. Pneumatic Connection (contd.) Connecting Spray Air (EP 34 S and EP 34 SD) Connect the spray air hose to the air connection (1). NOTE: The spray air may never be lubricated. 1 EPAH329S061A1297 Fig. 7 Lubricating or Not Lubricating the Control Air Hot melt application heads of the series EP 34 manufactured from 1997 on may be operated with lubricated as well as with non-lubricated control air. This has become possible due to modifications to the control module: Control module cylinder with a special inner coating Piston O-rings with an increased Shore hardness. NOTE: Lubricating the control air once means that the air must always be lubricated, because the lubricated control air washes out the factory-applied lubricant on the control modules and the solenoid valves. The new design control modules can be identified by an upper or lower indentation (see arrow, fig. 8). EPAH330S064A0997 Fig Nordson Corporation

17 Electropneumatic Hot Melt Application Heads 11 Operation with Non-Lubricated Control Air If new design control modules / application heads are connected to a compressed air system which has previously been lubricated, simply stopping the air lubrication is not sufficient. The lubricant residue in the system would get into the control modules and the solenoid valves. It would thus wash out the factory-applied lubricant on these parts, greatly reducing the lifetime of the components. For operating with non-lubricated control air ensure that: the unit is set to absolutely non-lubricated operation no oil leaking from a defective compressor gets into the air system control air is always supplied to the application head. It keeps the control modules closed when EMERGENCY OFF occurs or when the system comes to a standstill. This prevents adhesive from dripping out of the nozzle. NOTE: Nordson will assume no liability for damage resulting from unapproved air lubrication, not even for short periods of time. Operation with Lubricated Control Air The new design control modules or the application heads equipped with them can also be operated with lubricated air. NOTE: Lubricating the control air once means that the air must always be lubricated, because the lubricated control air washes out the factory-applied lubricant on the control modules and the solenoid valves. Use only this lubricant: Lubricant P/N Klüber Unisilkon TK002/ Nordson Corporation

18 12 Electropneumatic Hot Melt Application Heads 8. Installing Heated Hoses WARNING: Hot! Risk of burns. Wear heat-protective gloves. Connecting If there is cold hot melt material in the hose connection fitting (1) and/or hose connection (2), these components must be heated until the adhesive softens (approx. 80 C/176 F). 1. First connect the hose (3) electrically to the unit. 2. Heat application head and hose until the adhesive softens (approx. 80 C/176 F). 3. Screw the hose onto the unit. MXHH001S050B0997 Fig. 9 Disconnecting WARNING: System and hot melt material pressurized. Relieve pressure before disconnecting heated hoses. Failure to observe can result in serious burns. Relieving Pressure 1. Set motor speed(s) of the unit feeding the adhesive to 0 min -1 ; switch off motor(s). 2. Place a reservoir under the nozzle of the application head. 3. Activate the solenoid valve electrically or manually. Repeat this procedure until no more adhesive seeps out. 4. Re-use adhesive or dispose of properly according to local regulations. Second Open jawed Wrench Using a second open-jawed wrench prevents the hose connection fitting on the unit from turning. MXHH002S033A0295 Fig Nordson Corporation

19 Electropneumatic Hot Melt Application Heads 13 Operation WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. 1. Triggering Solenoid Valve Trigger the solenoid valve only when the application head is heated to operating temperature! If the adhesive is too cold, seals in the control module can be damaged. WARNING: Operate only with the voltage shown on the ID plate. 2. Setting Temperatures The procedure for setting the temperatures is described in the temperature controller manual. Temperature controllers are not part of the application head. They can be located e.g. in the electrical cabinet of a hot melt application unit or in a separate electrical cabinet. Maximum Operating Temperature 200 C / 392 F; 260 C / 500 F with the high temperature model. NOTE: The maximum operating temperature may not be exceeded. Nordson will assume no warranty or liability for damage resulting from incorrect temperature settings. 3. Adjusting Control Air Pressure The control air pressure for the control module is individually adjusted for each application with an external compressed air control valve. The compressed air control valve is not part of the application head. NOTE: Ensure that the application head is always provided with control air. The control air keeps the control modules closed when EMERGENCY OFF occurs or when the system comes to a standstill. This prevents adhesive from dripping out of the control modules. Maximum Control Air Pressure 6 bar / 0.6 MPa / 87 psi NOTE: The maximum control air pressure may not be exceeded. Nordson will assume no warranty or liability for damage caused by incorrect pressure settings Nordson Corporation

20 14 Electropneumatic Hot Melt Application Heads 4. Setting Adhesive Application Quantity The adhesive application quantity depends on the desired adhesive application weight and on the substrate speed. Settings are usually made with the pump speed dials. The optimum settings must be determined by trial and error. The speed dials are located e.g. in the electrical cabinet of the adhesive applicator or in a separate electrical cabinet. Depending on the model of the hot melt adhesive application system, the pump speed control can also occur with a tachometer generator or an electronic pressure controller. Stem Stroke Adjustment All control modules are equipped with a stem stroke adjustment used for fine metering of the adhesive quantity. Max mm Max in. 1 Figure 11 shows: WARNING: Hazard! The stem stroke adjustment knob has no upper setting limit. If compressed air is connected, never completely turn up the adjustment knob / adjustment screw; it may jump out. CAUTION: The stem stroke may only be adjusted when the application head is heated up! Failure to observe may cause damage to seals. Max mm Max in Latching stem stroke adjustment (1) Stem stroke adjustment with adjustment screw (2) and locknut (3) Non-adjustable stroke limitation (4). NOTE: The stem stroke adjustment knob has no upper setting limit; starting from the bottom, it may only be turned a maximum of 2 turns upward. This corresponds to a nozzle stem stroke of maximum 1.2 mm. Failure to observe may cause excessive wear or malfunction. Experience has shown that a stroke adjustment of max. 0.5 to 0.6 mm (which corresponds to 1 turn) has proven to be sufficient. Stem stroke Adhesive rate XXAH157S130A0797 Counterclockwise (+) = increase Clockwise ( ) = decrease Increase Decrease Fig Nordson Corporation

21 Electropneumatic Hot Melt Application Heads Adjusting Spray Pattern (EP 34 S) The spray air must always be warmed up with an air preheater. The spray pattern is optimized by alternately adjusting: Adhesive quantity (on the unit feeding the material) Stem stroke adjustment [on the application head (1)] Spray air pressure (on separate pressure controller) Spray air pressure [with adjusting screw (2)]. 1. Set spray air pressure to approx. 0.5 bar / 7.25 psi / 0.05 MPa. 2. Unscrew adjustment screw for spray air pressure (2) all the way by turning it to the left. 3. Trigger solenoid valve; material flows out. 4. Optimize spray pattern by changing the air pressure with the separate pressure controller. 5. Make fine adjustments to the spray pressure with the adjustment screw (2) (only necessary in exeptional cases). EPAH331S097A1297 Fig Nordson Corporation

22 16 Electropneumatic Hot Melt Application Heads 6. Adjusting Spray Pattern (EP 34 SD) The spray air must always be warmed up with an air preheater. The spray pattern is optimized by alternately adjusting: Adhesive quantity (on the unit feeding the material) A 1 I Stem stroke adjustment (on the application head) Spray air pressure (on separate pressure controller) Air adjustment screws I and A Release tube nut (2) by turning 1/2 rotation to the left. 2. Turn the air cap (3) such that the two outer pairs of holes are perpendicular to the direction of application. 3. Tighten tube nut (3). 4. On the separate pressure controller, set spray air pressure to approx. 3 bar / 43.5 psi / 0.3 Mpa; later adapt the spray air pressure to the spray pattern. 5. Trigger solenoid valve; adhesive seeps out. EPAH332S097A Set desired amount of material. Fig Stop air supply to the nozzle by turning the air adjustment screws I and A to the right. 8. Use the inner air adjustment screw I to set an even spray pattern. 9. Set the spray width needed with the outer air adjustment screw A Nordson Corporation

23 Electropneumatic Hot Melt Application Heads Settings Record Copy before filling out or use a pencil. Production information Adhesive Cleaning agent Basic settings Application head Basic settings Temperature Manufacturer Max. processing temperature Viscosity Manufacturer Flash point Control air pressure Spray air pressure Stem stroke (rotations) Heating zone application head Undertemperature Overtemperature Notes Form filled out by: Name Date 1998 Nordson Corporation

24 18 Electropneumatic Hot Melt Application Heads Maintenance WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. NOTE: Maintenance is an important preventive measure for maintaining operating safety and extending the operational lifetime of the unit. It should not be neglected under any circumstances. 1. Relieving Pressure WARNING: System and hot melt material pressurized. Before disconnecting heated hoses and replacing filter cartridges, relieve system pressure. Failure to observe can result in serious burns. WARNING: Hot! Risk of burns. Wear heat-protective gloves. 1. Set motor speed(s) of the unit feeding the material to 0 min -1 ; switch off motor(s). 2. Place a reservoir under the nozzle of the application head. 3. Trigger the solenoid valve electrically or manually. Repeat until adhesive no longer seeps out of the nozzle. 4. Re-use hot melt material or dispose of properly according to local regulations. EPAH208L058A0997 Fig. 14 Principle drawing material pressure relief 1998 Nordson Corporation

25 Electropneumatic Hot Melt Application Heads Daily Maintenance The stated intervals are based on general experience. Depending on the location of the unit, the production conditions and the operating time, other maintenance intervals may prove necessary. Unit Part Activity Interval Refer to Application head Inspection for damage External cleaning Daily Daily Page 19 Nozzle External cleaning Daily Page 20 Inspection for External Damage WARNING: If damaged parts endanger the operating safety of the application head and/or the safety of personnel, switch off the application head and have the damaged parts replaced by qualified personnel. Use only original Nordson spare parts. External Cleaning of Application Head External cleaning prevents impurities created during production from causing unit malfunctions. CAUTION: Do not damage or remove warning signs. Damaged or removed warning signs must be replaced by new ones. CAUTION: Never use hard tools. Use extreme care when handling the nozzle. Remove adhesive residue with a cleaning agent recommended by the adhesive manufacturer whenever possible. Heat with an air heater if necessary. Remove dust, fluffs, etc. with a vacuum cleaner or a soft cloth. Release coated Application Heads CAUTION: Do not use hard or metal tools to clean. Do not use wire brushes! The release coating could become damaged. Use only soft aids (wooden or PTFE spatulas or soft brushes) Nordson Corporation

26 20 Electropneumatic Hot Melt Application Heads 2. Daily Maintenance (contd.) External Cleaning of Nozzle CAUTION: Clean the nozzle very carefully; never use hard or metallic tools to clean. A damaged nozzle will result in uneven adhesive application, and it will need to be repaired. WARNING: Hot! Risk of burns. Wear heat-protective gloves. 1. Remove hot melt material residue from the nozzle promptly with a soft cloth. This should be done before the material cracks. 2. Remove severe and hardened residue with a wooden or PTFE spatula if necessary. 3. Regular Maintenance The stated intervals are based on general experience. Depending on the location of the unit, the production conditions and the operating time, other maintenance intervals may prove necessary. Unit part Activity Interval Refer to Application head Rinse with cleaning agent When soiled or when replacing adhesive Nozzle Disassemble and clean When soiled Control module Check leakage hole Weekly Filter (option) Separate manual Changing Type of Adhesive NOTE: Before changing the adhesive, find out whether the new adhesive may be mixed with the old. The adhesives may be mixed: The new adhesive can be used to rinse out the old adhesive. The adhesives may not be mixed: Thoroughly rinse with a cleaning agent recommended by the adhesive manufacturer. NOTE: Dispose of adhesive and cleaning agent according to local regulations Nordson Corporation

27 Electropneumatic Hot Melt Application Heads Maintenance Record Copy before filling out or use a pencil. Unit part Activity Date Name Date Name Application head Rinse with cleaning agent Nozzle Disassemble and clean Control module Check leakage hole Filter (option) Replace filter screen 1998 Nordson Corporation

28 22 Electropneumatic Hot Melt Application Heads Repair/Retrofitting WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. 1. Retrofitting Application Head with New Control Modules Beginning with units manufactured in 1997, EP 34 application heads may be operated with either non-lubricated or lubricated compressed air. If older models are to be retrofitted for operation with non-lubricated compressed air, the control modules must be replaced. If an older application head is going to be retrofitted in order to operate with non-lubricated control air, these measures must be taken: Replace control module with new design control module Replace solenoid valve Completely change the pressurized control air supply to absolute non-lubricated air. Adjust the stem stroke (see Stem Stroke Adjustment). 2. Replacing Single Control Modules If only some of the control modules of an application head are to be replaced, the application head must continue to be operated with lubricated control air. These lubricants may be used: Lubricant P/N Klüber Unisilkon TK002/ Klüber Unisilkon TK002/ Nordson Corporation

29 Electropneumatic Hot Melt Application Heads Removing and Installing Control Module WARNING: Hot! Risk of burns. Wear heat-protective gloves. 1. Heat up application head until adhesive softens 2. Unscrew fixing screws and remove the control module. NOTE: Nordson recommends completely replacing the control modules, as opposed to disassembling them. 3x P/N EPAH333S050A1297 Fig. 15 Removing 1. Heat up application head until adhesive softens. 2. Release fastening screws and remove control module. Installing 1. Heat up application head until adhesive softens. 2. If possible, apply mounting paste to the thread of the fixing screws to prevent seizing of the threads. Mounting paste: Never Seez, order no. P/N Replace O-ring(s). Order no. P/N Secure control module to application head and tighten screws Nordson Corporation

30 24 Electropneumatic Hot Melt Application Heads Troubleshooting 1. Troubleshooting Table The following troubleshooting table assumes that all other system components function correctly. Problem Possible Cause Corrective Action Refer to No adhesive Application head has not yet reached operating temperature Wait until temperature has been reached, check temperature setting if necessary Page 13 Not enough adhesive in the application unit Pump of the hot melt material application unit does not work Fill Check Control air not connected Connect Page 9 Nozzle blocked Clean nozzle Page 20 Filter (option) blocked Clean filter and replace filter screen Nozzle stem is stuck Replace control module Page 22 No adhesive: application head is cold Temperature not correctly set on temperature controller Set correct temperature Page 13 Plug has no contact Secure plug Page 8 Heater cartridge(s) defective Replace heater cartridge(s) Adhesive application is not exact Nozzle partially blocked or damaged Unscrew nozzle (when warm) and clean or replace Production parameters not attuned to one another Adjust parameters, change if necessary Unsuitable adhesive Consult adhesive manufacturer Data sheet The open time is too long The open time is too short Application temperature too high Set temperature lower Page 13 Unsuitable adhesive Consult adhesive manufacturer Data sheet Application temperature too low Set temperature higher Page 13 Unsuitable adhesive Consult adhesive manufacturer Data sheet 1998 Nordson Corporation

31 Electropneumatic Hot Melt Application Heads 25 Specifications 1. General Data NOTE: The specifications are valid only for standard application heads. Product Product Name Hot melt material application head (Options: release coating, high temperature (T version), high material flow rate (V version) Operating Voltage Power Consumption Refer to ID plate Refer to ID plate Type of Control Module Variations: Standard, Zero Cavity Filter (Option) Variations: none, 0.1 mm, 0.2 mm, 0.4 mm Nozzles Variations: 0.6 mm, 0.8 mm, 1.0 mm Temperature Sensor Variations: Fe-CuNi (FE/KO), Pt 100, Ni 120 Solenoid Valve Variations: MV 24-U 24 V DC, MV 240-1U 240 V AC, MV 110-1U 110 V AC Degree of Protection IP 30 Max. Control Air Pressure 6 bar / 0,6 MPa / 87 psi Hose Connection Fitting Variations: Inside diameter: 8 mm, 13 mm Max. Operating Temperature Max. Ambient Temperature for Solenoid Valves 200 C / 392 F; 260 C / 500 F with high temperature version Approx. 55 C / 131 F Weight Approx g 1998 Nordson Corporation

32 26 Electropneumatic Hot Melt Application Heads 2. Power Cables 8 Green/yellow Ground conductor 2 Blue 3 Brown Heater 4 Black 5 Black Solenoid valve Pin insert HAN 7D KWU 6 Red 7 Blue Thermo lead + Thermo lead XXAH135L046B0598 Fig. 16 Power cable for temperature sensor Fe-CuNi (FE/KO) 8 Green/yellow Ground conductor 2 Blue 3 Brown Heater 4 Black 5 Black Solenoid valve Pin insert HAN 7D KWU 6 Red (black) Temperature sensor Pt White (black) XXAH249L046B0598 Fig. 17 Power cable for temperature sensor Pt Black Black 3 5 Green/yellow Heater Temperature sensor Ni 120 Ground conductor XXAH129L046B0598 Fig. 18 Power cable with temperature sensor Ni Nordson Corporation

Hot Melt Application Head Series PW...

Hot Melt Application Head Series PW... Hot Melt Application Head Series... Manual English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice This

More information

Hot Melt Material Applicator MC 6

Hot Melt Material Applicator MC 6 Hot Melt Material Applicator Manual P/N 403 022 D English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice

More information

Sponge Cleaner. Manual P/N A English. Issued 05/03 NORDSON (UK) LTD STOCKPORT

Sponge Cleaner. Manual P/N A English. Issued 05/03 NORDSON (UK) LTD STOCKPORT Sponge Cleaner Manual P/N 768 651 A English Issued 05/03 NORDSON (UK) LTD STOCKPORT Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which is protected

More information

Drum Melters DG 21 / DG 201

Drum Melters DG 21 / DG 201 Drum Melters DG 21 / DG 201 Manual P/N 464 839 A - English - NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products

More information

Hot Melt Material Applicator MC 12 / MC 24

Hot Melt Material Applicator MC 12 / MC 24 Hot Melt Material Applicator Manual P/N 403 076 D English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice

More information

Hot Melt Applicator MC 405 for Foil Bags

Hot Melt Applicator MC 405 for Foil Bags Hot Melt Applicator for Foil Bags Manual English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY NOTE This manual is for products with the following P/N: 8015767 8022490 8027924 8037680 8018042 8023117 8031127

More information

Bulk Melters BM 200 with Piston Pump for 200 l Drums

Bulk Melters BM 200 with Piston Pump for 200 l Drums Bulk Melters BM 200 with Piston Pump for 200 l Drums Manual P/N 464 937 B - English - NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number

More information

U7698E Flame Detector

U7698E Flame Detector U7698E Flame Detector Customer Product Manual Issued 3/02 NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments, and inquiries about its products. General

More information

Bulk Melters BM 200 with Gear/Gerotor Pump for 200 l Drums

Bulk Melters BM 200 with Gear/Gerotor Pump for 200 l Drums Bulk Melters BM 200 with Gear/Gerotor Pump for 200 l Drums Manual P/N 464 958 C - English - NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order

More information

Envirocoat Twin Cyclone Powder Coating Booth

Envirocoat Twin Cyclone Powder Coating Booth Envirocoat Twin Cyclone Powder Coating Booth Manual P/N 779166 --English-- Keep for Future Reference Nordson China Sourcing - Shanghai Trademarks AccuJet, Aquaguard, Asymtek, Automotive, Autotech, Blue

More information

Fill Sentry. Automated Fill System. Customer Product Manual Part A. NORDSON CORPORATION

Fill Sentry. Automated Fill System. Customer Product Manual Part A. NORDSON CORPORATION Fill Sentry Automated Fill System Customer Product Manual Part NORDSON CORPORATION www.nordson.com CAUTION: If this equipment is used with other Nordson equipment, refer to the manuals provided with that

More information

Seal Sentry Series 10 Bead Detection System

Seal Sentry Series 10 Bead Detection System Seal Sentry Series 10 Bead Detection System Customer Product Manual P/N 321 289D02 This equipment is regulated by the European Union under WEEE Directive 2002/96/EC). See www.nordson.com for information

More information

Powder Conditioning System

Powder Conditioning System Powder Conditioning System Manual P/N 779168 --English-- Keep for Future Reference Nordson China Sourcing - Shanghai Table I Trademarks AccuJet, Aquaguard, Asymtek, Automotive, Autotech, Blue Box, CF,

More information

Level Monitor LA 100

Level Monitor LA 100 Level Monitor LA 100 Manual English NORDSON BENELUX MAASTRICHT THE NETHERLANDS www.nordson.com Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which

More information

Fluidking. Manual P/N A English NORDSON (UK) LIMITED STOCKPORT UK

Fluidking. Manual P/N A English NORDSON (UK) LIMITED STOCKPORT UK Manual P/N 768 643 A English NORDSON (UK) LIMITED STOCKPORT UK Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which is protected by copyright. Original

More information

Hot Melt Material Applicator MC 4420

Hot Melt Material Applicator MC 4420 Hot Melt Material Applicator Manual English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice This is

More information

Fixed Reclaim System

Fixed Reclaim System Fixed Reclaim System Manual P/N 779163 --English-- Keep for Future Reference Nordson China Sourcing - Shanghai Trademarks AccuJet, Aquaguard, Asymtek, Automotive, Autotech, Blue Box, CF, Can Works, Century,

More information

LA 820 / LA 820 RC Liquid Adhesive Gun

LA 820 / LA 820 RC Liquid Adhesive Gun Liquid Adhesive Gun Manual English NORDSON BENELUX MAASTRICHT THE NETHERLANDS Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which is protected by

More information

Hot Melt Applicators SB60 BoD

Hot Melt Applicators SB60 BoD Hot Melt Applicators Manual - English - Edition 06/14 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document applies to the entire series. Order number P/N = Order number for Nordson articles Note

More information

Hot Melt Material Applicator MC 7

Hot Melt Material Applicator MC 7 Hot Melt Material Applicator MC 7 Parts List P/N 735003A English Issued 2/06 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation

More information

Bulk Melters BM 200 with Piston Pump - EASY Pneumatics -

Bulk Melters BM 200 with Piston Pump - EASY Pneumatics - Bulk Melters BM 200 with Piston Pump - EASY Pneumatics - Manual - English - Issued 05/06 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note After approx. December 2003, this manual applies to the entire series.

More information

Hot-melt adhesive extruder EEX40

Hot-melt adhesive extruder EEX40 Hot-melt adhesive extruder EEX40 Manual 110900563/001 - English - Nordson Deutschland GmbH Buchholz-Mendt GERMANY Note This manual applies to the entire series. Part number P/N = 7549584 Notice This is

More information

Series AD-31 and Series L4 Extrusion Handguns

Series AD-31 and Series L4 Extrusion Handguns Series AD-31 and Series L4 Extrusion Handguns Customer Product Manual Issued 5/05 NORDSON CORPORATION DULUTH, GEORGIA USA www.nordson.com For CE Declaration, refer to melter documentation. Nordson Corporation

More information

DuraDrum Bulk Melters DD200

DuraDrum Bulk Melters DD200 DuraDrum Bulk Melters Manual English Issued 11/07 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice This

More information

GD-500 Bead Detection System

GD-500 Bead Detection System GD-500 Bead Detection System Customer Product Manual Issued 4/08 NORDSON CORPORATION DULUTH, GEORGIA USA www.nordson.com Nordson Corporation welcomes requests for information, comments, and inquiries about

More information

Liquid Adhesive Detection System Alarm Box

Liquid Adhesive Detection System Alarm Box Liquid Adhesive Detection System Alarm Box Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products.

More information

FillEasy C Adhesive Feed System

FillEasy C Adhesive Feed System FillEasy C Adhesive Feed System Customer Product Manual Issued 5/10 This document contains important safety information Be sure to read and follow all safety information in this document and any other

More information

Non-RTD Hot Melt Hose Replacement

Non-RTD Hot Melt Hose Replacement Instruction Sheet P/N 7C 0 Safety WARNING: System pressurized! Relieve system hydraulic pressure before breaking any hydraulic connection or seal. Failure to relieve the system hydraulic pressure can result

More information

Automatic Hot Melt Melter/Feeder Retrofit Kit Mechanical Float Model. Part104506A

Automatic Hot Melt Melter/Feeder Retrofit Kit Mechanical Float Model. Part104506A Automatic Hot Melt Melter/Feeder Retrofit Kit Mechanical Float Model Part456A NORDSON CORPORATION. AMHERST, OHIO USA Corporation welcomes requests for information, comments and inquiries about its products.

More information

Replacing a Gun Thermostat

Replacing a Gun Thermostat Instruction Sheet Replacing a Gun Thermostat WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation.

More information

Bulk Melters AltaPail

Bulk Melters AltaPail Bulk Melters AltaPail Manual - English - Edition 02/12 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document is for products with the following P/N: 7165698 7157455 7157502 7157503 Order number

More information

Hot-melt adhesive extruder EEX100

Hot-melt adhesive extruder EEX100 Hot-melt adhesive extruder EEX100 Manual 111121287/001 -- English -- NordsonDeutschlandGmbHBuchholz--MendtGERMANY Note This manual applies to the entire series. Part number P/N = 7552471 Notice This is

More information

AltaSpray Plus Applicators

AltaSpray Plus Applicators AltaSpray Plus Applicators Customer Product Manual Issued 5/3 This document contains important safety information Be sure to read and follow all safety information in this document and any other related

More information

CleanSpray System Operation

CleanSpray System Operation Nordson Corporation OPERATOR S CARD P/N 108684C CleanSpray System Operation Introduction The individual manuals for the CleanSpray Gun, CleanSpray Controller and Model 25B Pump are included with each component.

More information

FC-2200 Flame Detector

FC-2200 Flame Detector FC-2200 Flame Detector Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence

More information

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER OPERATING MANUAL MODEL AIR 500TM AIR DRYER Puregas, LLC 226-A Commerce St. Tel: 800-52-535 Broomfield, Colorado Fax: 303-657-2205 P/N P0255 REV A, 02/9/4 TABLE OF CONTENTS.0 GENERAL... 3 2.0 SPECIFICATIONS...

More information

PRO 2000i LOW LEVEL DEPOSITOR

PRO 2000i LOW LEVEL DEPOSITOR DEPOSITORS AND AUTOMATED CAKE PRODUCTION SYSTEMS PRO 2000i LOW LEVEL DEPOSITOR OPERATION AND SPARE PARTS MANUAL Serial No. PR2L- (Please quote this number when ordering spares, and making service calls)

More information

Operating Instructions for Reka Hot-Melt Glue Applicators

Operating Instructions for Reka Hot-Melt Glue Applicators Operating Instructions for Reka Hot-Melt Glue Applicators TR 700 TR 70 TR 80 TR 60 TR 50.4 TR 55 Table of Contents 1. Product Description 3 2. General Safety Instructions 4 3. Safety Measures to be taken

More information

Instruction Manual Suppository Penetration Tester. Type PM 30

Instruction Manual Suppository Penetration Tester. Type PM 30 Instruction Manual Suppository Penetration Tester Type PM 30 ERWEKA GmbH * Ottostr. 20 22 * 63150 Heusenstamm * Germany * Tel: +49 (0) 6104 6903-0 Fax: +49 (0) 6104 6903-40 * E-mail: info@erweka.com *

More information

Product Manual for Pneumatic Reka Glue Guns

Product Manual for Pneumatic Reka Glue Guns Product Manual for Pneumatic Reka Glue Guns www.pakarte.com TR 60 LCD TR 70 LCD Translation from German to English TR 80 LCD TR 55 LCD TR 700 TR 50.4 TR 50.4 25 TR 55 LCD TR 60 LCD TR 700 TR 70 LCD TR

More information

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro 2006/01 Content Important Information 1. Notes... 3 1.1 CE - Labeling... 3 1.2

More information

POLYMIX PX-IG 2000 Operating Instructions

POLYMIX PX-IG 2000 Operating Instructions POLYMIX PX-IG 2000 Operating Instructions Voltage D 100-120V, 50/60 Hz D 210-250V, 50/60 Hz Please check that the voltage is correct and corresponds with the nameplate on the back of the machine. Manual

More information

Flameproof Manual Call Points

Flameproof Manual Call Points Operating instructions Additional languages www.r-stahl.com CS & Clifford & Snell Contents General Information.... Manufacturer.... Information regarding the operating instructions.... Further documents....

More information

Platen Heater Pad Replacement

Platen Heater Pad Replacement Instruction Sheet P/N Platen Heater Pad Replacement WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related

More information

ColorMax Cyclone Cleaning Kit

ColorMax Cyclone Cleaning Kit Instruction Sheet P/N 637 0 WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Description See

More information

INSTRUCTION MANUAL W-400

INSTRUCTION MANUAL W-400 USE and MAINTENANCE INSTRUCTION MANUAL Bellaria WBX WB GRAVITY SPRAY GUN Series LPH-400 WB en it fr es pt de se TECHNICAL DATA Classic Plus Series LPH-400 (LVLP) Classic Plus Nozzle_Needle set Combination

More information

MC2000 OPERATING AND CALIBRATION INSTRUCTIONS

MC2000 OPERATING AND CALIBRATION INSTRUCTIONS MC2000 OPERATING AND CALIBRATION INSTRUCTIONS CONTENTS 1 - CERTIFICATE OF CONFORMITY... 3 2 - PRESENTATION... 4 2. 1 - GENERAL... 4 2. 2 - CHARACTERISTICS... 4 2. 3 - OPERATING PRINCIPLE... 5 2. 3. 1 -

More information

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50 -30 Installer manual Air/air heat pump -40/50 IHB GB 1516-1 331554 Table of Contents 1 Important information 2 5 Installation 7 Safety information 2 Model combinations 7 Read before starting the installation

More information

Service package PDAD- -SP (en) Assembly instructions d [ ]

Service package PDAD- -SP (en) Assembly instructions d [ ] Service package PDAD- -SP-12000 (en) Assembly instructions 8068819 1701d [8068821] Original instructions Installation and commissioning are to be carried out only by qualified personnel in accordance with

More information

Hot -melt adhesive extruder EEX100 -F5B2X2TWXMQXS

Hot -melt adhesive extruder EEX100 -F5B2X2TWXMQXS Hot -melt adhesive extruder EEX100 -F5B2X2TWXMQX Manual 110717869/001 -- English -- Nordson Deutschland GmbH D Buchholz--Mendt D GERMANY Note This manual applies to the entire series. erial no. 110717869/001

More information

Adsorption dryer PDAD. (en) Operating instructions g [ ]

Adsorption dryer PDAD. (en) Operating instructions g [ ] Adsorption dryer PDAD (en) Operating instructions 8068814 1701g [8068816] Original instructions Installation and commissioning are to be carried out only by qualified personnel in accordance with the operating

More information

USE and MAINTENANCE INSTRUCTION MANUAL GRAVITY. WS-400 EVO LS-400 Entech. SPRAY GUN Series. en it fr es pt de se

USE and MAINTENANCE INSTRUCTION MANUAL GRAVITY. WS-400 EVO LS-400 Entech. SPRAY GUN Series. en it fr es pt de se USE and MAINTANCE INSTRUCTION MANUAL WS-400 EVO LS-400 Entech GRAVITY SPRAY GUN Series en it fr es pt de se TECHNICAL DATA WS-400 WS-400 EVO WS-400 Clear WS-400 Base WS-400-1301 EVO 1.3 170 365 260 WS-400-1401

More information

MODULAR AUTOMATIC GRANULAR ICE FLAKER

MODULAR AUTOMATIC GRANULAR ICE FLAKER MODULAR AUTOMATIC GRANULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24479 rev. 03 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on having

More information

Instruction Manual. Automatic fuel oil de-aerator SMART-FLO 3/K B100 COMPATIBLE

Instruction Manual. Automatic fuel oil de-aerator SMART-FLO 3/K B100 COMPATIBLE Sid Harvey s 605 Locust Street Garden City, NY 11530 Instruction Manual Automatic fuel oil de-aerator SMART-FLO 3/K Read manual before use! Observe all safety information! Keep manual for future use! 05.2015

More information

AUTOMATIC MODULAR ICE-CUBE MAKER WITH VERTICAL EVAPORATOR SYSTEM

AUTOMATIC MODULAR ICE-CUBE MAKER WITH VERTICAL EVAPORATOR SYSTEM AUTOMATIC MODULAR ICE-CUBE MAKER WITH VERTICAL EVAPORATOR SYSTEM INSTRUCTIONS AND WARNINGS 24481 ed. 11-2007 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear

More information

ASSEMBLY & OPERATING INSTRUCTIONS

ASSEMBLY & OPERATING INSTRUCTIONS SD-BASIC SPRAY DRYER ASSEMBLY & OPERATING INSTRUCTIONS 1) Introduction 2) Safety / COSHH 3) General Safety Rules 4) Components Included 5) Packing List 6) Connection to Electrical Supply 7) Assembly and

More information

Eldex Column Heater. Operator s Manual

Eldex Column Heater. Operator s Manual Eldex Eldex Column Heater Operator s Manual Eldex Laboratories, Inc. 30 Executive Court Napa, CA 94558 Tel: (707) 224-8800 Fax: (707) 224-0688 www.eldex.com Rev. B: 081700 2000Eldex Laboratories, Inc.

More information

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax Part# 1000692 7/12/99 tn INSTRUCTIONS This manual contains important information concerning the installation and operation of the gun washers listed at the right. Read manual thoroughly and keep for future

More information

Product Manual Glue Applicators MS 80 and MS 200

Product Manual Glue Applicators MS 80 and MS 200 Product Manual www.pakarte.com Glue Applicators MS 80 and MS 00 Translation from German to English Table of Contents Product Description General Safety Instructions Safety Measures to be taken during Operation

More information

Explorer CleaningPartsDirect.com Carpet Extractor. Operator and Parts Manual. Home Find... Go To.. Model No.: Can.

Explorer CleaningPartsDirect.com Carpet Extractor. Operator and Parts Manual. Home Find... Go To.. Model No.: Can. Explorer 1500 Carpet Extractor Model No.: 608808 609231 Can. Operator and Parts Manual CleaningPartsDirect.com 662-393-3045 NOBLES 12875 RANSOM STREET HOLLAND MI 49424 U.S.A. CUSTOMER SERVICE: 1-800-365-6625

More information

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS Dear Customer, Congratulations on having chosen a quality product which will certainly fully meet your expectations. Thank you for having purchased

More information

Econo-Coat RCM 8000 Powder Spray Booth Installation Guide

Econo-Coat RCM 8000 Powder Spray Booth Installation Guide Installation Guide P/N 1028657A Econo-Coat RCM 8000 Powder Spray Booth Installation Guide WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this

More information

AUTOMATIC GRANULAR ICE FLAKER

AUTOMATIC GRANULAR ICE FLAKER AUTOMATIC GRANULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24480 rev. 01 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on choosing a

More information

Fiber Optic Module. Part B NORDSON CORPORATION AMHERST, OHIO USA

Fiber Optic Module. Part B NORDSON CORPORATION AMHERST, OHIO USA Fiber Optic Module Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence to Nordson Corporation

More information

Models: GW/R-T GW/R-2-T GW/R-3-T

Models: GW/R-T GW/R-2-T GW/R-3-T Part# GW/R-T-OM 1/12/04 TN Models: GW/R-T GW/R-2-T GW/R-3-T This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly

More information

CBT LW MAINTENANCE GUIDE

CBT LW MAINTENANCE GUIDE CBT LW MAINTENANCE GUIDE PICTOGRAMS Each Signifier displayed here is specific to this User Manual. Menu Previous Advance Note Tip Example Powder Feeder Mixing Bowl Weigh Scale CBP Tanks Control Panel PSD

More information

HH80C HYDRAULIC CRIMP TOOL

HH80C HYDRAULIC CRIMP TOOL HH80C HYDRAULIC CRIMP TOOL DATASHEET SEE PAGE 8 FOR IMPORTANT INFORMATION CONCERNING LIMITED WARRANTY, AND LIMITATION OF LIABILITY INTRODUCTION: The HH80C is a hand actuated hydraulic crimp tool designed

More information

Page 1 of 18. Part# /5/2013

Page 1 of 18. Part# /5/2013 Part# 1002655-06 8/5/2013 This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly and keep for future reference INSTRUCTIONS

More information

HDLV 55-Gallon Powder Drum Unloader

HDLV 55-Gallon Powder Drum Unloader Instruction Sheet P/N 07333 0 HDLV -Gallon Powder Drum Unloader Description See Figure. The HDLV -gallon powder drum unloader uses a Prodigy HDLV High Capacity pump to supply virgin powder to a powder

More information

Pneumatic agitator A MAN R

Pneumatic agitator A MAN R Pneumatic agitator A MAN R Operation manual MAG00001EN, V05 www.durr.com N6804... Dürr Systems AG Application Technology Carl-Benz-Str. 34 74321 Bietigheim-Bissingen Telephone: +49 7142 78-0 Internet:

More information

Dosing system. Commissioning and maintenance manual eco-pen300

Dosing system. Commissioning and maintenance manual eco-pen300 Dosing system Commissioning and maintenance manual eco-pen300 Item number 20506 Print 21.2.12 Contents 1 This Manual 5 2 The dispenser 5 3 Safety 5 4 Starting up for the first time 6 4.1 Inserting the

More information

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN. INSTALLATION, OPERATION & SERVICE MANUAL FOR COOLER TYPES OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN. 1. Introduction This manual is a guide for the installation, maintenance

More information

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Original Installation Instructions 810437-08 Contents Foreword... 3 Availability... 3 Formatting features in the document... 3 Safety... 3 Use for the intended purpose...

More information

AUTOMATIC ICE-CUBE MAKER

AUTOMATIC ICE-CUBE MAKER AUTOMATIC ICE-CUBE MAKER INSTRUCTIONS AND WARNINGS 24478 ed. 11-2007 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on having chosen

More information

PS-2/ES Automated pack & tag machine with IndES fastening system

PS-2/ES Automated pack & tag machine with IndES fastening system English Manual PS-2/ES Automated pack & tag machine with IndES fastening system Contents 1. Introduction 2. Important Safety Instructions 3. PS-2/ES 4. Unpacking the machine 5. Setting up the machine 6

More information

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters Operating Instructions for the BBO-1 and BBO-2 Basket Blasters 2101 West Cabot Boulevard Langhorne, PA 19047-1893 www.empire-airblast.com Page 2 Model Number: Serial Number: Date of Purchase: Date of Installation:

More information

GETZ EQUIPMENT INNOVATORS PART NO.: 9G58619 MODEL: SV1 150 PR VACUFILL SYSTEM (Revised 2/25/14)

GETZ EQUIPMENT INNOVATORS PART NO.: 9G58619 MODEL: SV1 150 PR VACUFILL SYSTEM (Revised 2/25/14) GETZ EQUIPMENT INNOVATORS PART NO.: 9G58619 MODEL: SV1 150 PR VACUFILL SYSTEM (Revised 2/25/14) !!WARNING!! SEVERE DAMAGE AND/OR INJURY MAY RESULT DO NOT DISCHARGE ANY EXTINGUISHER CYLINDER EXCEEDING 195

More information

Bedienungsanleitung. Ideas for dental technology. Made in Germany C

Bedienungsanleitung. Ideas for dental technology. Made in Germany C Bedienungsanleitung 216604 C 01022013 Made in Germany Ideas for dental technology GLISH Instruction manual 1. Introduction...1 1.1 Employed Symbols...1 2. Safety...2 2.1 Intended use...2 2.2 Improper use...2

More information

Models Series Series

Models Series Series Models 31800-Series 31801-Series INDUSTRIAL DIAPHRAGM PUMPS 4 GPM/15 LPM FEATURES Self-Priming Easy Installation Can run dry without damage Low Amp Draw Flow to 4 GPM/15 LPM Compact Size Thermal Overload

More information

NEPTUN I Sole cleaning unit Art.-No.:

NEPTUN I Sole cleaning unit Art.-No.: Assembly and operating instructions Please read the instruction carefully before assembling and putting into operation. Keep instruction for future reference. Contents. General 2. Function 3. Installation

More information

Operational Instructions. Glue Applicator MS Translation from German to English

Operational Instructions. Glue Applicator MS Translation from German to English Operational Instructions Glue Applicator MS 200 Translation from German to English Table of Contents Product Description 1 General Safety Instructions 2 Safety Measures to be taken during Operation 3 Start-up

More information

AUTOMATIC MODULAR ICE-CUBE MAKER

AUTOMATIC MODULAR ICE-CUBE MAKER AUTOMATIC MODULAR ICE-CUBE MAKER INSTRUCTIONS AND WARNINGS 24851 ed. 06-2012 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on having

More information

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314) DRY AIR SYSTEMS, INC. 2655 Metro Boulevard Maryland Heights, Missouri 63043 (314) 344-1114 fax (314) 344-0677 HD SERIES DRIERS TABLE OF CONTENTS WHY AN AIR DRYER 3 WHAT IS A DESICCANT AIR DRYER 3 Desiccant

More information

Models Series Series

Models Series Series Models 3180-Series 3181-Series INDUSTRIAL DIAPHRAGM PUMPS Commercial Duty, 3 GPM/1 LPM FEATURES Sealless Easy Installation Run Dry Ability Flow to 3 GPM/1 LPM Self-Priming Low Amp Draw Thermal Overload

More information

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System 1 Revised 11/18/10 2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website: www.getzequipment.com LIMITED

More information

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98)

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98) 32506 Upholstery and Drapery Cleaner Model No.: 32506 3 gal Extractor Operator and Parts Manual KLEENRITE 1122 MAPLE STREET MADERA CA 93637 U.S.A. FAX: 1-559-673-5725 CUSTOMER SERVICE: 1-800-241-4865 MNL32506

More information

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL 456 Creamery Way, Exton, PA 19341, USA Phone: 610.524.8800 Fax: 610.524.8807 Email: info@refrigerantid.com www.refrigerantid.com Page

More information

Industrial Vacuums, Inc

Industrial Vacuums, Inc Instructions/Spare Parts Manual Nilfisk Model GWD255 Drum Top Vacuum CAUTION: This Nilfisk vacuum cleaner is not to be used in explosion-hazardous areas, as serious injury could result. Under no circumstances

More information

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2 Cleaning unit for coolant :_decftez`_>r_fr] Book No.: 1271526-02 V2 Alfa Laval Separation AB Separator Manuals, dept. SKEL S-147 80 Tumba, Sweden Telephone: +46 8 53 06 50 00 Telefax: +46 8 53 03 10 40

More information

AUTOMATIC MODULAR ICE FLAKER

AUTOMATIC MODULAR ICE FLAKER AUTOMATIC MODULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24479 rev. 08 It is strictly forbidden to reproduce this instruction manual or any part thereof. 1 5 3 4 Mod. N. V. W 2 2 M8 18 8 18 M8 M8 3 ~ 200

More information

Chemical resistant Vacuum Pumps

Chemical resistant Vacuum Pumps Chemical resistant Vacuum Pumps C300 / C400 / C410 / C510 / C600 / C610 English Operating Manual WIGGENS labortechnik GmbH Mühsamstrasse 3610249 Berlin Germany Fon:+49 30 42105470 Fax:+49 30 42105971 E-Mail:

More information

ORIGINAL OPERATING INSTRUCTIONS ASH VACUUM CLEANER / 18L

ORIGINAL OPERATING INSTRUCTIONS ASH VACUUM CLEANER / 18L ORIGINAL OPERATING INSTRUCTIONS 02-11 ASH VACUUM CLEANER / 18L IMPORTANT! SAFETY INSTRUCTIONS When using the appliance, a few safety precautions must be observed to avoid injuries and damage. Please read

More information

SOLUS-500 EXTRACTOR 120V

SOLUS-500 EXTRACTOR 120V SOLUS-500 EXTRACTOR 120V INFORMATION & OPERATING INSTRUCTIONS DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY 1. Always use

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC AQB09JJ6WC_IM_E_2585 2006.4.17 4:26 PM Page 17 INSTALLATION MANUAL Indoor Unit AQB09JJWC AQB12JJWC Outdoor Unit UQB09JJWC UQB12JJWC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

Section 11. Electrical System. 42--CF200--MA--08 (formerly 42-65) Issued 5/96 P/N B. E 1996 Nordson Corporation All rights reserved

Section 11. Electrical System. 42--CF200--MA--08 (formerly 42-65) Issued 5/96 P/N B. E 1996 Nordson Corporation All rights reserved ection 11 Electrical ystem 11-0 Electrical ystem Table of Contents i Table of Contents ection 11 Electrical ystem 1. Introduction... 11-1 Electrical Operation... 11-1 Heating Zones... 11-2 2. Electrical

More information

Installation & Operating Guide

Installation & Operating Guide 5-036 HOT WATER TANK Installation & Operating Guide Read all instructions thoroughly. Keep this guide for future reference. Proof of purchase is required for Warranty. Staple receipt or proof of purchase

More information

USER S MANUAL ATH WH220

USER S MANUAL ATH WH220 USER S MANUAL ATH WH220 INDEX INTRODUCTION... - 3 - General information s... - 3 - Description of pneumatic jack... - 4 - Operation of jack... - 5 - Technical data... - 6 - Dimension drawing... - 6 - INSTALLATION...

More information

Owner s Manual READ AND SAVE THESE INSTRUCTIONS

Owner s Manual READ AND SAVE THESE INSTRUCTIONS 16 Outdoor Misting / Oscillating Fan Model Number: AMMF16R-1 Owner s Manual READ AND SAVE THESE INSTRUCTIONS CAUTION: Before using this product, read this manual and follow all safety rules and operating

More information

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator Wallace & Tiernan Gas Feed Systems V2000 Chlorinator Introduction Siemens Water Technologies chlorination equipment has the benefit of 100 years of experience in gas feed technology. V2000 chlorinators

More information

RESISTENT EXTRA 3592, 3602 RESISTENT EXTRA PLUS 3592P, 3602P

RESISTENT EXTRA 3592, 3602 RESISTENT EXTRA PLUS 3592P, 3602P RESISTENT EXTRA 9, 0 RESISTENT EXTRA PLUS 9P, 0P D A CH Gebrauchsanleitung... GB IRL AUS USA NZ CDN IND Instructions for Use... 1 F CH B NL CDN Mode d'emploi... 18 E MEX Instrucciones de uso... I CH Istruzioni

More information