DAIKIN's Experience in the production with R32
|
|
- Amos Farmer
- 6 years ago
- Views:
Transcription
1 The 4th Regional Symposium on Alternative Refrigerants for High-Ambient Countries; Risk Assessment of Future Refrigerants in Production, Installation, and Service Dubai, UAE (28-29 Oct, 2014) DAIKIN's Experience in the production with R32 29/10/2014 DAIKIN Industries Ltd. Tadafumi Mikoshi
2 Disclaimer 2 The contents of this presentation have been compiled based on the newest technical information available and every effort has been made to ensure that the presentation is accurate and up to date. However, the accuracy of the information shall not be guaranteed, and Daikin Industries, Ltd. and/or its affiliates shall bear no responsibilities whatsoever for any damage that may be caused as a result of using information and documents contained in this presentation. Check & follow relevant local laws and standards on your own responsibilities.. CSRJOB
3 Field US Europe International Contents Refrigerant Classification Usage Restriction for Safety International Standards for Product design The Main premise of factory safety ISO & IEC followed perfectly for product design ASHRAE 34 UL NA- (based on ISO) ISO817 ASHRAE 15 EN378 ISO UL 207 UL 250 UL 471 UL 474 UL 484 UL 984 UL 1995 UL EN IEC Ed.5.0:2013 Calling in A2L General safety standard Product Safety Standard 3
4 Basic Technology R32 AC Manufacturing 4 Challenges Lower Flammability AC products Safety Quality Productivity Technology analysis in the sight of Refrigerant HFC HCFC R32 R32 AC R410A Manufacturing Technology AC Manufacturing of R22 Methodologies Risk assessment & Flammability countermeasure Higher Level of Clean DRY Tight Lubricant Oil change Clean DRY Tight General Safety, Quality Productivity General Manufacturing for industrial Products CSRJOB Kaizen 5S Activity TQC TQM etc. Occupational Safety and Health
5 Main Changes from R22 5 Refrigerant Change I Contamination II Chemical Corrosion III Pressure V Flammability R32 R410A Synthetic Oil Polyol Ester Ether Byproducts when mixed HNBR (Hydrogenated Nitrile -Butadiene Rubber) HFC-resistant Nylon Higher Reliability High Pressure =4.15MPa 1.6 times Pressure Lower flammable A2L Flammability Countermeasures R22 Mineral Oil Suniso Polychloroprene (CR or Neoprene) Middle Pressure =2.9MPa Non flammable A1 Higher level of Clean Dry Tight required same as R410A CSRJOB
6 Details of Clean Dry & Tight 6 Clean No contamination Dry No moisture Tight No Leakage PHENOMINON CAUSES Oxidized film by brazing Entering of foreign items such as dust, particles and oil from outside. Rain drop infiltration at poor transportation quality. Moisture condensation inside the pipe. Insufficient brazing Inadequate flaring or insufficient tightening torque. Inadequate tightening of flange connection. PROBLEM Clogging of expansion valve, capillary tube, etc. Poor performance of cooling or heating. Degradation of refrigerant lubricant oil. Malfunction of compressor. Gas shortage Higher Temperature of discharge gas.
7 Checking Points for Clean Dry & Tight 7 The block diagram below is an example of AC manufacturing line, focusing on the 3 basic rules Clean Dry Tight. Confirm pressure intensity of equipment, pipe, hose, connection coupler, etc. against higher pressure of R32 refrigerant. Piping/Heat exchanger line Carry out measures against residual scrap from processing C Carry out leakage test T Material Processing Brazing Air-tight test Completion Purchased parts C D Carry out measures against residual oil C Observe basic rules for brazing work C T Care of completed components C D Assembly line Carry out vacuum drying D Assemble piping Air-tight test Vacuum drying Refrigerant charging Insulation / Withstand voltage test Operation test Leakage test Fitting out to completion Observe basic rules for brazing work Carry out leakage test T Carry out leakage test T C T Purchased parts Care of purchased parts C Clean D Dry T Air-tight C D CSRJOB
8 Flammability & Three conditions for Ignition 8 Coestablishment of following Three conditions is mandatory for ignition 1. Existence of Flammable material Leakage Air flow analysis Complete Tightness & Equipment Maintenance Contactor* Enough Ventilation & no air stagnation 2. Mixture with Oxygen at certain density Electrical safety & Isolation of ignition source *Rarely ignition of R32 with 200 V 60A 3. Existence of Ignition Source
9 Key Considerations for Safety - Gas handling 9 When storing cylinders Valves must be closed tightly Cylinders must be stored in a cool (below 40 ) space, in a dry space to prevent corrosion and in well ventilated space. Cylinders must be kept away from direct sunlight or fire. Measures must be taken to protect the valve against external impacts or damage. When handling cylinders Use of cylinders under high temperature or near strong sparks* and flames is forbidden. *High power around 20KW or more. The cylinders must be handled with care, avoiding external impacts. When attaching or detaching cylinders to or from the equipment, sufficient care must be taken to avoid leakage. When handling the refrigerant The space of refrigerant handling must be in low temperature and sparks and flames free. Workers must be equipped with appropriate protective equipment to avoid contact with eyes or skin, or inhaling. The refrigerant must not be released into the air. The area for the production equipment must have a structure with ventilation to prevent refrigerant stagnation. CSRJOB
10 Key Considerations for Safety - General 10 Regardless of the type of refrigerant, the following points must be observed inside factories at all times. Provide and keep safe and healthy work environment To prevent gas stagnation inside the factory, provide openings to create a well-ventilated environment. To Carry out local exhaust ventilation and total ventilation inside the factory. Example) Industrial Safety and Health Act of Japan Keep enough openings area, equivalent to 1/20 of the factory floor area, or Install ventilation equipment with a capacity of over 30m 3 /h/person. To keep temperature, humidity, luminance, noise and chemical atmosphere in the factory at certain level regulated by the authority. Carry out 5S Activity (Seiri: Sort / Seiton: Set in Order / Seiso: Shine / Seiketsu: Sanitize / Shitsuke: Sustain) Clearly separate necessary parts from unnecessary parts, and dispose unnecessary parts. Keep all parts in their specified locations, and make sure they are accessible at all times. Keep the working area and equipment clean at all times, maintaining a clean workplace. Clean, sort and tidy up parts and working area. Make a habit of keeping rules and carrying out work in the correct order. CSRJOB
11 Heinrich s Law 11 1 Serious injury or death 29 Major Injury 300 Near Misses Unsafe Acts & Conditions
12 R32 Flammability Countermeasures 12 Risk Assessment Kaizen & 5S Complete implementation R32 of conventional Flammability regulation & standers cover R32 Flammability Countermeasures Countermeasures General Occupational Safety and Health Complete Implement of Clean Dry Tight No special investment is required Local Regulation
13 13 Reality of R32 AC manufacturing Line Detailed Examples of equipment installation
14 AC factory and various equipment 14 Tightness test Control Panel Refrigerant charge Refrigerant Leakage Test Final Operation Test Gas detector Gas detector Press Machine Parts cleaning High pressure gas Refrigerant Supply Vacuum pump
15 Blocking pipe end 15 Prevent contamination and moisture from entering into the refrigerant piping parts during storage or transportation of parts. Compressor suction and discharge pipes should be capped. End of piping should be capped N 2 (Nitrogen) should be sealed inside the compressor (positive pressure) Check the measurement to prevent from entering moisture and contamination, such as above. Refrigerant pipes should be stored inside vinyl bags CSRJOB
16 Air blow cleaning of the pipes 16 Blow low pressure air to remove oil in pipes. Remove any contamination and moisture from the low pressure air using a drier, etc. <Compressor for low pressure air> <Drier> (moisture removal) After the moisture is removed, use the low pressure air for blowing (contamination removal) <Heat exchanger> Toshiba Industrial Products and Systems Corp. oducts/industrial.htm Not displayable SMC Corp. paration/ Daikin s example <Contamination removal using low pressure air blowing> Contamination removal Low pressure air blowing Heat exchanger tubes (pipes) Contamination Remove any contamination and moisture remaining inside the piping. CSRJOB
17 Chemical Corrosion Proof on Hose and Coupler 17 Product connection hose Change the inside surface material of the hose to HFC-resistant nylon. Product connection coupler Change rubber seal specifications. (CR HNBR) Coupler for equipment connection Change rubber seal specifications. (CR HNBR) Please contact manufacturers of your equipment regarding chemical attack on the parts of equipment (i.e. hose or coupler).
18 Air-tight Test by High Pressure Compressor 18 Equipment specifications (pressure) R22 (HCFC) equipment specifications 1 2 Equipment operation pressure (MPa) 2.9 Equipment design pressure (MPa) 3.5 R32 (HFC) equipment specifications Equipment operation pressure (MPa) 4.15 High pressure compressor for air-tight test Equipment design pressure (MPa) 5.0 Daikin's example Kajitech Corp. Not displayable Daikin s recommendation for special specification: oil-free type 1 Equipment operation pressure indicates the product design pressure. 2 Equipment design pressure indicates the equipment s design pressure.
19 Refrigerant Charging Equipment / Medium Speed Type Medium pressure type and exclusive use for R32 Equipment specifications (pressure) R22 (HCFC) equipment specifications Equipment operation pressure (MPa) 2.0 Equipment design pressure (MPa) R32 (HFC) equipment specifications Equipment operation pressure (MPa) 3.0 Equipment design pressure (MPa) 3.53 Refrigerant charging instrument (Mass flow type) Daikin's example To-ou Kogyo Co,. Ltd. Not displayable
20 Refrigerant Charging Equipment / High-speed Type 20 High pressure type and exclusive use for R32 Equipment specifications (pressure) R22 (HCFC) equipment specifications Equipment operation pressure (MPa) 2.92 Equipment design pressure (MPa) 4.0 Daikin's example R32 (HFC) equipment specifications Equipment operation pressure (MPa) 3.92 Equipment design pressure (MPa) 5.0 Refrigerant charging equipment (Measuring cylinder type) CSRJOB To-ou Kogyo Co,. Ltd. Not displayable Daikin s recommendation for special specification: double piston cylinder *Double piston cylinder: refrigerant charging equipment which has separated refrigerant piston and hydraulic piston
21 Operation Testing Equipment 21 Higher pressure type and exclusive use for R32 R22 (HCFC) equipment specifications <Operation testing instrument (refrigerant piping system)> Equipment specifications (pressure) Equipment operation pressure (MPa) 2.92 Equipment design pressure (MPa) 3.5 R32 (HFC) equipment specifications <Operation testing instrument (refrigerant piping system )> Equipment operation pressure (MPa) 4.15 Equipment design pressure (MPa) 5.0 Piping system must be separated to ensure R32 does not mix with other refrigerants. (Use specialized refrigerant piping system.) CSRJOB
22 Refrigerant Leakage Test Detectors for HFC (R32) 22 Since R32 (HFC) does not contain Cl (Chlorine), halogen-type* refrigerant leakage test detectors (Chlorine detector) can not be used for R32 units. *Halogen-type is not enough accurate to detect R32. R22 R32 refrigerant leakage detectors (examples of use) Daikin's example Halogen type Semiconductor type Infrared type Infrared type D4302 Suzuki Giken Co,. Ltd. 500, ,000 JPY/unit AIMEX-008XR PRO AEMSS Inc. 800,000 JPY/unit Not displayable HLD5000 INFICON Co,. Ltd. 1,000,000 JPY/unit
23 Conclusion 23 AC manufacturing is integrated technology. Clean, Dry & Tight are basic and mandatory requirements for AC manufacturing, especially for HFC(R410A,R32) AC R32 flammability countermeasure can be covered by complete implementation of conventional standards and regulation. No special investment required. No golden rule for Safety. Ceaseless effort and maintenance required. Top management involvement and leadership absolutely required for safety management. Check & follow relevant local laws and standards on your own responsibilities.
24 24
HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI
NO. S051-800 ISSUED: MAR. 26, 2010 REVISED: HOSHIZAKI COUNTER SHOWCASE MODEL HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B SERVICE MANUAL IMPORTANT This manual should be read carefully
More informationR-407A R-448A R-449A
GUIDELINES FOR THE UTILIZATION OF R-407A R-448A R-449A 2018 Tecumseh Products Company LLC. All rights reserved. Page 1 of 9 R-407A, R-448A, and R-449A are recognized as suitable alternative refrigerants
More informationReference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.
GUIDELINES FOR THE UTILIZATION OF R-404A R-452A Page 1 of 10 GUIDELINES FOR THE UTILIZATION OF R-404A AND R-452A For many years, R-404A has emerged as the industry's major choice as an alternative refrigerant
More informationSafety concerns for A2L refrigerants in AC service procedures
Safety concerns for A2L refrigerants in AC service procedures Alternative Refrigerants for High-Ambient Countries; Risk Assessment of Future Refrigerants in Production, Installation, and Service 28 October
More informationOWNER S MANUAL (English)
TRS600 IGNITION PROOF SERIES Refrigerant Recovery Machines OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS600, TRS600K, TRS600S Evaluated for performance
More informationTECHNICAL & SERVICE MANUAL
SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL & SERVICE MANUAL No. OCH468 REVISED EDITI-A HFC utilized R4A June 2 [Model name] MXZ-8B48NA PAC-AKA5BC PAC-AKA3BC (Indispensable
More information14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.
HET- 190 ESL Support page 1 CORE Basic Refrigeration Circuit 1. Liquid refrigerant boils in the evaporator. Heat is absorbed. The heat energy absorbed converts refrigerant liquid into vapor. 2. Refrigerant
More informationOilless Refrigerant Recovery System. OWNER S MANUAL (English) TO BE OPERATED BY QUALIFIED PERSONNEL ONLY
Pro-Set TR500 SERIES Oilless Refrigerant Recovery System OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TR500, TR500E, TR500J, TR500S TO BE OPERATED
More informationDevelopment of HFC-134a Compressor for Domestic Refrigerator
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 1994 Development of HFC-134a Compressor for Domestic Refrigerator I. Iwahashi Sanyo Electric
More informationAE R4 July 2015 Guide for the Use of R-290 Refrigerant in Copeland Refrigeration Compressors
July 2015 Guide for the Use of R-290 Refrigerant in Copeland Refrigeration Compressors TABLE OF CONTENTS Safety Safety Instructions... 2 Safety Icon Explanation... 2 Instructions Pertaining to Risk of
More informationChapter 6. Do s & Don ts in Refrigeration & Air-Conditioning Servicing
Do s & Don ts in Refrigeration & Air-Conditioning Servicing Who is Better? OR Common Practices that are damaging to the Refrigeration & Air-conditioning Systems Brazing with Cu electrode for brazing Cu
More informationKSGD-01W/S SEMI CONDUCTOR STAND ALONE REFRIGERANT LEAK DETECTOR. Instructions for :- KSGD-01W/S Semi Conductor Standalone Refrigerant Leak Detector
Issue 1 KSGD-01W/S SEMI CONDUCTOR STAND ALONE REFRIGERANT LEAK DETECTOR Installation Manual Instructions for :- For safe and correct use please read the installation manuals supplied with the equipment.
More informationTRS21 IGNITION PROOF SERIES
TRS21 IGNITION PROOF SERIES 2 Cylinder Commercial Recovery Machine OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS21A, TRS21E TO BE OPERATED BY QUALIFIED
More informationVacuum system component SELVACS
Vacuum system component SELVACS Vacuum related components CC-796A 1 Wide variations for an assortment of applications New SELVACS vacuum components respond to a wide range of applications from fine work
More informationTRS21 IGNITION PROOF SERIES
TRS21 IGNITION PROOF SERIES 2 Cylinder Commercial Recovery Machine OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS21, TRS21C, TRS21S Evaluated for
More informationCS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)
CS*/CD*/CP* Series Air Cooled Condensing Units Operating and Installation Manual CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2) TABLE OF CONTENTS I. Receipt of Equipment 2 II. Piping...4 III. System
More informationPublication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS
Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS Refrigerant R22 is widely used for residential and commercial air conditioning, as well as commercial refrigeration
More informationSERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS
Classification: Reference: Date: HA94-005 NTB94-091 September 26, 1994 SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS APPLIED VEHICLE(S): All models except Quest equipped with a retrofitted A/C system SERVICE
More informationA: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.
1/1/12 RS-45 (R434A): Q & A 1 Q: What is RS-44? 1.Q: What is RS-45 A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. 2 Q: Yes, but what does RS-45 contain? A: RS-45 is
More informationOWNER S MANUAL (English)
TR600 Series Refrigerant Recovery Machines OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TR600, TR610, TR600C, TR610C, TR600S, TR600K, TR600E TO BE
More informationDEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION
Thomas Leck, PhD DuPont Fluorochemicals 2010 NEXT ACR Tokyo International Exchange Center 17 Feb 2010 DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION
More informationDLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS
DLCLRA INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 Fig. 1 - Size 36 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING...
More informationA/C Refrigerant. Air Conditioning systems use refrigerant to move heat from air inside the car to air outside the car
A/C Refrigerant Air Conditioning systems use refrigerant to move heat from air inside the car to air outside the car Refrigerants are HAZARDOUS to you and the environment Motor Vehicle Air Conditioning
More informationANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 1 GENERAL
Annex 2, page 2 ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 1 GENERAL Section 1 Application 1 The following new sentence is added to the end of paragraph 1.2:
More informationInstallation Instructions
24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons Installation Instructions Fig. 1-24AHA4 A07532 SAFETY CONSIDERATIONS Improper installation, adjustment, alteration,
More informationRefrigerant Recovery Machine. Model No Operating Manual
Refrigerant Recovery Machine Model No. 25700 Operating Manual Safety Precautions WARNING : TO PREVENT PERSONAL INJURY AND / OR EQUIPMENT DAMAGE, CAUTION - Risk of injury. This equipment should only be
More informationSECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.
SECTION 15650 REFRIGERATION EQUIPMENT PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories. B. Related Section: 1. 11400
More informationREFRIGERANT SYSTEM SERVICE WARNINGS
2005 HVAC Refrigerant System - MX-5 Miata REFRIGERANT SYSTEM SERVICE WARNINGS USING/HANDLING UNAPPROVED REFRIGERANT Using a flammable refrigerant, such as OZ-12, in this vehicle is dangerous. In an accident,
More informationAuto Air Conditioning Compressors GENERAL CATALOGUE
Auto Air Conditioning Compressors GENERAL CATALOGUE Refrigeration & AirConditioning Equipments Co., Ltd Technology Innovation Design Quality 技术革新设计质量 WWC5H Series 5 Pistons Compressors General Features:
More informationUse of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning
Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning This initiative was developed by: Content and guidance kindly provided by the following organisations: Cool Drive CPS Asia Pacific
More informationAdditional users operating manual
Additional users operating manual For use with A2L Refrigerants e.g. R32, 1234yf, 143a, 1234ze This additional manual is valid for the following Promax Refrigerant Recovery Units: MiniMax-E; RG 5410A-E,
More informationAOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO
AOYG8LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL For authorized service personnel only. English PART NO. 93778639 93778639_IM.indb /20/20 6:07:25 PM AIR CONDITIONER OUTDOOR UNIT INSTALLATION
More informationSERVICE MANUAL OUTDOOR UNIT. No. OBH789
OUTDOOR UNIT SERVICE MANUAL HFC utilized R32. Models MUZ-AP25VG - E1, ET1 MUZ-AP25VGH - E1 MUZ-AP35VG - E1, ET1 MUZ-AP35VGH - E1 MUZ-AP42VG - E1, ET1 MUZ-AP42VGH - E1 MUZ-AP50VG - E1, ET1 MUZ-AP50VGH -
More informationThis chapter is devided into two sections:
This chapter is devided into two sections: Page Installation requirements........................................................................ 127 The installation process..........................................................................
More informationResidential Piping and Long Line Guideline
AC / HP R-410A Refrigerant Systems Single-Stage, Two-Stage and Variable Speed Models Residential Piping and Long Line Guideline TABLE OF CONTENTS Safety Considerations... 2 Definitions... 2 Introduction...
More informationHorizontal/Side Discharge Condensing Units
INSTALLATION, OPERATION & MAINTENANCE MANUAL Horizontal/Side Discharge Condensing Units Models CMA12SD-0 CMA18SD-1 CMA24SD-1 CMA30SD-1 CMA36SD-1 CMA48SD-1 517.787.2100 www.marsdelivers.com Horizontal/Side
More informationSelection of a refrigeration oil for the R32 refrigerant and evaluation of the compressor reliability
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2014 Selection of a refrigeration oil for the refrigerant and evaluation of the compressor
More informationHow to deal with ...R410A MITSUBISHI ELECTRIC R32 R125 R410A AIRCONDITIO NING
How to deal with R32 R125 R410A...R410A MITSUBISHI ELECTRIC AIRCONDITIO NING R410A Contents What is R410A?......................................... 3 Expressions...........................................
More informationInstallation Instructions
38MHR Outdoor Unit Single Zone Ductless System Sizes 09 to 24 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. NOTE: Images are for illustration purposes
More informationA study on retrofit methodologies for legacy air-conditioning systems to reduce their impact on global warming and ozone depletion
A study on retrofit methodologies for legacy air-conditioning systems to reduce their impact on global warming and ozone depletion Prepared for the Public Commenting Meeting of Ph.D program February 28,
More informationHigh Efficiency Technologies for Small and Medium-Sized Air Conditioning Equipment Using R410A. Hitachi Appliances, Inc.
1 High Efficiency Technologies for Small and Medium-Sized Air Conditioning Equipment Using R410A Hitachi Appliances, Inc. 2 Introduction The situation faced by the refrigeration / air conditioning industry
More informationCC Series VACUUM PUMPS
CC Series VACUUM PUMPS OPERATING MANUAL Thank you for selecting a Javac select product! Please read this operation manual carefully before use. Only suitably qualified personnel should operate this equipment.
More informationGENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.
Fig. 2: Blower & Evaporator Unit Specifications 2004 HVAC SYSTEMS Manual HVAC System - Sorento GENERAL SPECIFICATIONS AIR CONDITIONER Fig. 1: Air Conditioner Specifications BLOWER AND EVAPORATOR UNIT HEATER
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS MODEL LV8 COMMERCIAL REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 A01001 7/11/96 NRP-OM-LV8 7/96
More informationDue to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.
TECHNICAL DATA SHEET R434A () Features and uses of R-434A () is a non-flammable HFC mixture. ODP = 0, compatible with traditional mineral lubricants, alkyl benzene and also with synthetic POE, so there
More informationInstallation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E
EB99802801-1 Installation Manual RBM-PMV0363E RBM-PMV0903E Installation Manual English OUTDOOR UNIT SIDE UPPER INDOOR UNIT SIDE Thank you very much for purchasing TOSHIBA Air conditioner. Please read this
More informationBringing Hydrocarbon to the Market Training & Certification
Bringing Hydrocarbon to the Market Training & Certification GIZ Proklima side-event 24 th Meeting of the Parties 13 th November 2012, Geneva Switzerland Rolf Huehren Rolf.huehren@proklima.net GIZ Proklima,
More informationRefrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A Leading the Industry with Environmentally Responsible Refrigerant Solutions Emerson Climate Technologies, Inc. does not advocate
More informationGeneral safety precautions English
English A min (m 2 ) 550 530 540 510 520 490 500 470 480 450 460 430 440 410 420 390 400 370 380 350 360 330 340 310 320 290 300 270 280 250 260 230 240 210 220 190 200 170 180 150 160 130 140 110 120
More informationGeneral safety precautions English
English A min (m 2 ) 550 530 540 510 520 490 500 470 480 450 460 430 440 410 420 390 400 370 380 350 360 330 340 310 320 290 300 270 280 250 260 230 240 210 220 190 200 170 180 150 160 130 140 110 120
More informationHVACR Refrigeration
Western Technical College 10601101 HVACR Refrigeration Course Outcome Summary Course Information Description Career Cluster Instructional Level Total Credits 4.00 Total Hours 108.00 This course is an introduction
More informationReducing Refrigerant Leakage
Reducing Refrigerant Leakage Mike Nankivell F.Inst.R Marketing Director Space Airconditioning plc President of HEVAC Chairman ACRIB F Gas Group An Introduction to Real Zero Information provided by Cool
More informationSERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11
SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual No.: 2100-479 Supersedes: NEW File: Volume
More informationINSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC
AQB09JJ6WC_IM_E_2585 2006.4.17 4:26 PM Page 17 INSTALLATION MANUAL Indoor Unit AQB09JJWC AQB12JJWC Outdoor Unit UQB09JJWC UQB12JJWC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)
More informationUser manual Flushing device VAS 6337/1a
User manual Flushing device VAS 6337/1a 2 Content Safety warnings 3 Flushing with R134a refrigerant 4 1.0 Preparing the Vehicle AC System 4 1.1 Connecting the recovery recharge Unit 6 1.2 Flush procedure
More informationDuctless Split Air Conditioner
Ductless Split Air Conditioner Installation Manual Indoor HSU09VHG(DB)-W HSU12VHG(DB)-W HSU18VHH(DB)-W HSU24VHG(DB)-W Outdoor HSU09VHG(DB)-G HSU12VHG(DB)-G HSU18VHH(DB)-G HSU24VHG(DB)-G Table of Contents
More informationAC 1 AIR CONDITIONING SYSTEM
AC1 AC2 GENERAL INFORMATION REFRIGERATION SYSTEM Prevention of Release and Excessive quantities (CFCs) for automobile air conditionings is be lieved to cause harm by depleting the ozone layer which helps
More informationInstallation Instructions
38MPRA Outdoor Unit Single Zone Ductless System Sizes 09 to 12 Installation Instructions NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes
More informationChapter 2. Alternatives to HCFCs and their Characteristics
Alternatives to HCFCs and their Characteristics Refrigerant - General Chemical used in a cooling system, such as an air conditioner or refrigerator, as the heat carrier which changes from vapour to liquid
More informationMEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS
ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Features, Dehumidification Principles, Order Codes 209 Specifications, Dimensions 210 Dry Air Flow Rate,
More informationCondensing Unit Installation and Operating Instructions
Bulletin WCU_O&I 01 June 2003 Condensing Unit Installation and Operating Instructions WCU Air Cooled Condensing Unit Table of Contents Section 1. Section 2. Section 3. Section 4. Section 5. Section 6.
More information1. General Description
1. General Description A: SPECIFICATIONS 1. HEATER SYSTEM Heating capacity 2. A/C SYSTEM AUTO A/C MODEL Item Specifications Condition 5.0 kw (4,300 kcal/h, 17,062 BTU/h) or more AC-2 Mode selector switch:
More information12 In Row. Installation Manual. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.
MISSION CRITICAL Air Conditioning Systems 12 In Row Installation Manual ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 2 Table of Contents Table of Contents... 3 Site
More informationRequirements of refrigerant leak detector and alarm for air conditioning and refrigeration equipment
STANDARD OF THE JAPAN REFRIGERATION AND AIR CONDITIONING INDUSTRY ASSOCIATION Requirements of refrigerant leak detector and alarm for air conditioning and refrigeration equipment JRA 4068T :2016R Translated
More informationCaresaver Universal Refrigerant Recovery Unit
Operation Manual Caresaver Universal Refrigerant Recovery Unit 2 CONTENTS CHAPTER 1 INTRODUCTION AND OVERVIEW Specifications 3 Health and Safety 4-5 Component Location and Identification 6-9 CHAPTER 2
More informationRefrigerant Recovery Unit, Model RRU134
Installation, Operation & Maintenance Manual IOMM RRU134 Group: Refrigerant Effective: December 2000 Supersedes: New Refrigerant Recovery Unit, Model RRU134 1999 McQuay International Table of Contents
More informationGeneral safety precautions English
English 1 1 1.1 About the documentation The original documentation is written in English. All other languages are translations. The precautions described in this document cover very important topics, follow
More informationLSM PUMPER Sigenvej 7 DK 9760 Vrå Tlf.: Fax USERS GUIDE FOR LSM PUMPS TYPE
LSM PUMPER Sigenvej 7 DK 9760 Vrå Tlf.: +45 9898 1900 Fax. +45 9898 2440 USERS GUIDE FOR LSM PUMPS TYPE 10 15 19 25 32 40 50 65 80 100 125 150 200 Index Declaration of conformity 3 Conditions of usage
More informationDAIKIN AIR CONDITIONER
3P226011-1A M07B242A DAIKIN AIR CONDITIONER Two-dimensional bar code is a code for manufacturing. Safety Precautions (1) Read these Safety Precautions carefully to ensure correct installation. This manual
More informationINSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA
TXV Coils for Manufactured Housing EMA NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance,
More informationINSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC
AQB8J6WC_IM_E_25864 2006.4.4 3:29 PM Page 7 INSTALLATION MANUAL Indoor Unit AQB8J6WC AQB24J2WC Outdoor Unit UQB8J6WC UQB24J2WC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)
More informationAir Conditioning & Duracool Emery Stora
Air Conditioning & Duracool Emery Stora X Low refrigerant Clutch cut off switch * *Leaves compressor as High pressure gas **Leaves condenser as High pressure liquid ** Changes from a high Pressure liquid
More informationInstaller manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50
-30 Installer manual Air/air heat pump -40/50 IHB GB 1516-1 331554 Table of Contents 1 Important information 2 5 Installation 7 Safety information 2 Model combinations 7 Read before starting the installation
More informationINSTALLATION MANUAL. Outdoor Unit. Indoor Unit FILE NO. A Cooling Only Model. Heat Pump Model. Heat Pump Model
FILE NO. A03-0 INSTALLATION MANUAL Unit MMU-AP009H, AP0H, AP05H, MMU-AP08H, AP04H, AP07H, MMU-AP030H, AP036H, AP048H MMU-AP056H MMU-AP007WH,
More informationGeneral safety precautions English
English 1 1 Units are marked with the following symbol: 1.1 About the documentation The original documentation is written in English. All other languages are translations. The precautions described in
More informationAFTER SALES SERVICE DIV. SM 21
AFTER SALES SERVICE DIV. SM 21 CONTENTS 1. Trouble about refrigerant piping work (Page) 1-1) Trouble on cutting copper tubes!! 1(above) 1-2) Problem of storage of copper tubes!! 1(below) 1-3) Trouble caused
More informationAUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM
Guangzhou Junliye Import&Export Co., Ltd. AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM OPERATION MANUAL 1. Cautions: Wear the glove and eye protection glass to protect the skin and eyes from
More informationPressure Switches Precautions 1 Be sure to read this before handling.
Pressure Switches Precautions 1 Design / Selection 1. Confirm the specifications. Products represented in this catalog are designed ony for use in compressed air systems (including vacuum). Do not operate
More informationSplit Air Conditioner
Split Air Conditioner Owner's Manual Residential Air Conditioners Thank you for choosing Residential Air Conditioners,please read this owner s manual carefully before operation and retain it for future
More informationEnspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS
Enspeco AUTOMOTIVE REFRIGERANT MANAGEMENT SYSTEMS RMS 5000 INSTRUCTIONS The Enspeco Refrigerant Management System 5000 provides fast and efficient recovery, recycling and charging of automotive air conditioning
More informationSERVICE MANUAL MUZ-LN25VG MUZ-LN35VG MUZ-LN50VG MUZ-LN60VG OUTDOOR UNIT. No. OBH767. Models HFC R32
OUTDOOR UNIT SERVICE MANUAL HFC utilized R32. Models MUZ-LN25VG MUZ-LN35VG MUZ-LN50VG MUZ-LN60VG - E1, ER1, ET1 - E1, ER1, ET1 - E1, ER1, ET1 - E1, ER1, ET1 Indoor unit service manual MSZ-LN VGW/V/B/R
More informationNO. F ISSUED: JUN. 15, 2009 REVISED: HOSHIZAKI MODULAR CRESCENT CUBER KMD-201AA KMD-201AWA MODEL SERVICE MANUAL
NO. F037-775 ISSUED: JUN. 15, 2009 REVISED: HOSHIZAKI MODULAR CRESCENT CUBER MODEL KMD-201AA KMD-201AWA SERVICE MANUAL CONTENTS PAGE I. SPECIFICATIONS ---------------------------------------------------------------------------------------
More informationWMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS
WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS **WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER** Altering the product or replacing parts with non authorized factory parts voids all warranty
More informationFully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified
Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified Thank you for purchasing our fully-automatic gas-fired tankless water heater. Please completely read this Manual
More informationOPERATION & MAINTENANCE MANUAL TC670
OPERATION & MAINTENANCE MANUAL TC670 Refrigerant Management Center (Convertible For Use With R12 or R134a) RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80342-02 TC670 CONVERTIBLE
More informationINSTALLATION INSTRUCTIONS
2016 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS Elite Series XC16 Units AIR CONDITIONER 507161-01 8/2016 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE General This
More informationSome of these procedures need to be performed to conform to requirements of the Clean Air Act.
Leak Detection, Recovery, Evacuation and Charging Four basic service procedures used to repair and maintain a mechanical refrigeration system are leak detection, evacuation, recovery, and refrigerant charging.
More informationSeminar HCFC ALTERNATIVES FOR THE FOAM SECTOR TECHNOLOGIES AND EQUIPMENT SOLUTIONS July 2014 Chapecó (SC) Brazil
Seminar HCFC ALTERNATIVES FOR THE FOAM SECTOR TECHNOLOGIES AND EQUIPMENT SOLUTIONS 23 24 July 2014 Chapecó (SC) Brazil ABOUT EKOSYSTEM Located in Italy, Ekosystem has been producing Polyurethane machinery
More informationDLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS
DLCSRA INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes only.
More informationRefrigeration Dryers WDRD
Refrigeration Dryers WDRD Series Refrigeration Dryers WDRD Key Features: n Plug & Play Design for Easy Installation and Operation (WDRD10 - WDRD125). n Small Space Saving Design. n Oversized Demister Separator
More information1. ACCESSORIES SUPPLIED WITH THE AIR CONDITIONER 2. LOCATION OF INDOOR AND OUTDOOR UNIT 3. INSTALLATION/SERVICE TOOLS (ONLY FOR R410A PRODUCT) 4.
1. ACCESSORIES SUPPLIED WITH THE AIR CONDITIONER 2. LOCATION OF INDOOR AND OUTDOOR UNIT 3. INSTALLATION/SERVICE TOOLS (ONLY FOR R410A PRODUCT) 4. INSTALLATION OF THE INDOOR UNIT 5. CONDENSATE HOSE CONNECTION
More informationCLI Refrigerant Gas Leak Detector. User s Guide
el-520 CLI20204 Refrigerant Gas Leak Detector User s Guide Congratulations on the purchase of the AccuTools el-520 Refrigerant Gas Leak Detector, the most technologically advanced of its kind. The el-520
More informationa. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system
Core 1. Ozone in the stratosphere above the earth consists of: a. Molecules containing 3 oxygen atoms. b. Molecules of 2 oxygen atoms. c. Radioactive particles. d. Pollutants that have risen from ground
More informationPositively Innovative R32 R32. Instructions for Use and Handling
Positively Innovative R32 Refrigerants R32 Instructions for Use and Handling 2 Contents Foreword 4 1 Characteristics 5 1.1 Characteristics 5 1.2 Flammability 6 1.3 Saturated Vapor Pressure / Temperature
More informationOWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:
OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS: 79202-00 79202-05 79202-30 79202-35 Approval Agency s Model 79202-00 & 79202-05 Model 79202-30 & 79202-35 Not recommended for pumping acid,
More informationHP-500 Ozone Generator
HP-500 Ozone Generator With proper care and maintenance, this device should give you years of trouble-free service. Please take the time to read this manual so that you may safely operate your ozone generator
More informationInstallation Instructions
PREFERREDT SERIES AIR CONDITIONER WITH PURONR REFRIGERANT 1-1/2 TO 5 NOMINAL TONS Installation Instructions Fig. 1 --- 538A NOTE: Read the entire instruction manual before starting the installation. TABLE
More informationand Refrigerant Identifier
Contaminated Refrigerant and Refrigerant Identifier What is contaminated refrigerant? Two or many type of refrigerants mixed in the cylinder or Refrigeration and air-conditioning system knowingly or unknowingly
More informationRESOLUTION MSC.292(87) (adopted on 21 May 2010) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS
RESOLUTION MSC.292(87) THE MARITIME SAFETY COMMITTEE, RECALLING Article 28(b) of the Convention on the International Maritime Organization concerning the functions of the Committee, NOTING resolution MSC.98(73)
More informationAE R1 Application Guidelines for ZB*KAU Copeland R-290. August Scroll Compressors
Application Guidelines for ZB*KAU Copeland R-290 August 2018 Scroll Compressors TABLE OF CONTENTS Safety... 3 Safety Instructions... 3 Safety Icon Explanation... 3 Instructions Pertaining to Risk of Electrical
More information