Danfoss Air Heating Surfaces

Size: px
Start display at page:

Download "Danfoss Air Heating Surfaces"

Transcription

1 MAKING MODERN LIVING POSSIBLE Installation Guide

2 Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive 200/42/EC) 2012 Copyright Danfoss A/S

3 Table of Contents 1 Electrical Heating Surfaces Electrical pre-heating surfaces Electrical after heating surfaces Placing an electrical heating surface Connecting an electrical heating surface Overview - System with one heating surface Overview - System with two heating surfaces Troubleshooting Waterborne Heating Surfaces Waterborne after heating surfaces Placing a waterborne heating surface Connecting a waterborne heating surface Call for Heating Troubleshooting Geothermal Heating Surfaces Geothermal heating surfaces Dimensioning of ground collectors Laying ground collectors Filling with brine Placing a geothermal heating surface Connecting a geothermal heating surface Troubleshooting Technical Data Electrical heating surfaces Waterborne heating surfaces Geothermal heating surfaces Electrical Heating Surfaces 1.1 Electrical pre-heating surfaces An electrical pre-heating surface is used to keep the Air system temperature above the freezing point. Air systems without pre-heating will gradually reduce the air intake volume during long term operation at outside temperatures below -3 C in order to prevent freezing. In a standard house this is an excellent solution, but in airtight buildings (typical low-energy constructions), the imbalance can cause a non-desirable negative pressure inside the house. Installing a pre-heating surface is therefore recommended here. The electrical pre-heating surface is built into the duct system on the outdoor air side. A: Extract air. B: Supply air. C: Outdoor air. D: Exhaust air. A E: Sensor before heating surface. F: Sensor after heating surface. B G: Supply cable to heating surface H: Supply cable to automatic function. I: Communication cable HRV unit -> external controller. J: Post-heating (to be insulated with 50 mm glass/mineral wool). K: External controller (must not be insulated). Note! The electrical heating surface must be installed by a certified electrician. I H 230V, 50 Hz K G F E C 50 cm J 50 cm D Danfoss Heating Solutions VIFKB502 3

4 1.2 Electrical after heating surfaces An electrical after heating surface is used to slightly raise the supply air temperature to prevent discomfort in the room. The electrical after heating surface is built into the duct system on the supply side. A: Extract air. B: Supply air. C: Outdoor air. D: Exhaust air. E: Sensor before heating surface. F F: Sensor after heating surface. G: Supply cable to heating surface H: Supply cable to automatic function. H I: Communication cable HRV unit -> external controller. J: Post-heating (to be insulated with 50 mm glass/mineral wool). K: External controller (must not be insulated). Note! The electrical heating surface must be installed by a certified electrician. 50 cm J 50 cm 230V, 50 Hz G K E A B I C D 1.3 Placing an electrical heating surface The heating surface must be placed at a minimum distance of 2 x the diameter of the duct size to the nearest obstacle (pipe bends, external filters or unit). An arrow on the heating surface indicates the air flow direction. The heating surface must be placed at least 30 mm from any wooden building components. The connection box should face upwards or horizontally - never downwards. The heating surface must be insulated with non-flammable insulating material. The cover of the surface s external controller must NOT be insulated, but must remain visible so that the manual over-heating protection can be deactivated if this is triggered unexpectedly. The two factory mounted PT-1000 sensors must be placed in the duct system 50 cm in front of and 50 cm behind the surface. Each sensor is marked if it should be placed before or after surface. If the sensors face the wrong way, the required operations cannot be achieved. Drill Ø8 mm holes in the duct and install the supplied rubber grommets, then place the sensors into the duct. Fix the sensors to the pipe with duct tape and insulate together with the rest of the duct system and heating surface. Insulation Rubber sleeve PT-1000 sensor 45 mm min. 2 x A mm A mm min. 2 x A mm 1.4 Connecting an electrical heating surface The mains lead from the supplied external controller (marked supply voltage 230 V, 50 Hz ) is connected to the mains power, using a suitable junction box. We recommend that the heating surfaces be supplied from a separate group. The power cable from the external controller (marked to heating surface ) is connected to the electrical heating surface, cf. electrical diagram. The supply cable for the heating surface is fed through the pre-punched holes in the heating surface junction box. A cable gland must be used to provide strain relief. The communication cable is mounted between the external controller and the ventilation system s serial input (also see the following pages). 4 VIFKB502 Danfoss Heating Solutions

5 OBS: 120 Ohms modstand mellem klemme 2 & Gråt modbus stik, set fra tilslutningsside Klemme 1: Orange Klemme 2: Blå (+modstand) Klemme 3: Hvid/blå (+modstand) Klemme 4: Tom N L PE 24 2 Installation Guide 1. PT 1000 sensor, behind surface (control sensor). 2. PT 1000 sensor in front of the surface. 3. Communication cable between the HRV unit and mounting case (10 m, twisted pair, 2 pairs + display). 4. The power cable, 230 V, 50 Hz, should be connected to a separate 10 A group (3 m, 3G1.5). 5. Heating surface connection (3 m 3G1.5).. Over-heating thermostat with automatic re-closure (70 C). 7. The over-heating thermostat with manual closure (120 C). 8. Element. Note! The control box must not be insulated Solid state relæ PE N L Overview - System with one heating surface 1. Unit. 2. Heating surface controller. 3. CCM module. 4. Air Dial. 5. Serial cable, heating surface controller / unit.. Serial cable, CCM module / unit Mounting sequence - carried out on the serial socket in the unit 1. Twist together in pairs the serial cables with same colour. 2. Crimp-on ferrules are recommended. 3. Insert the cable pairs into the unit connector White / Orange 1 2. Orange 3. Black 4. White / Blue 5. Blue. Remove jumper between terminals 5 and 5. Insert the connector into the unit. Within four minutes the Air Dial will recognise the connected heating surface and automatically register it with the system New device found Danfoss Heating Solutions VIFKB502 5

6 1. Overview - System with two heating surfaces 1. Unit. 2. Heating surface 1 controller, without termination resistance. 3. Heating surface 2 controller, with termination resistance 4. CCM module. 5. Air Dial.. Serial cable, CCM module / unit. 7. Serial cable, controller 1 / unit. 8. Serial cable, controller 2 / controller Mounting sequence 1. Heating surface external controller 1 is mounted as shown in chapter 1.5. Remove the termination resistance T on heating surface Connect surface 1 to surface 2: 1. Orange / Orange 2. Blue / Blue 3. White-Blue / White-Blue 4. Empty White / Orange 1 2. Orange 3. Black 4. White / Blue 5. Blue. Remove jumper between terminals 5 and 4. Insert the connector into the unit. Within four minutes the Air Dial will recognise the connected heating surface and automatically register it with the system New device found VIFKB502 Danfoss Heating Solutions

7 1.7 Troubleshooting Error indication Reason Solution The surface does not automatically register, when connecting power to the control. The surface cuts out because of the over-heating protection. When a surface is connected, it can take up to four minutes before it is included in the network. A communication cable has not been connected correctly. The termination resistance is not correctly positioned for the last unit in the chain. Flow across the surface is too low. Duct sensors mounted incorrectly/ wrong way round. A component in the duct system is mounted too close to the heating surface (bend, filter, reduction, etc.). Wait four minutes and check the Air Dial, if any new units have been added to the system. Check if communication cables are mounted correctly and the colour codes between the individual cables are according to this guide. Make sure that a termination resistance is mounted only on the last unit in the system. Check for air passages in the system. This type of fault is often due to insulation material residue in the duct system. Once the fault has been found and corrected, the heating surface s over-heating protection is re-set manually. This is done using the red button on the top of the heating surface. Power to the actual ventilation system is then switched off briefly, after which operations can be re-started. Check the label on the temperature sensors; sensor labels show where the sensor should be placed in the system in relation to the heating surface. The component that is disrupting the airflow across the surface must be moved so that the heating surface is covered evenly. Fuses blown in main power supply The phase is overloaded. Supply the heating surface from a separate 10A fused group. Unpleasant draughts/smells Dust coating on the heating surface It can be expected, that an electrical heating surface will give off a slightly burnt smell when first used (or after a long period where it has not been in use). This is a short-term issue and will disappear in a short time. The smell is due to small particles of dust on the surface of the heating surface getting hot. The surface does not give off any heat The surface s over-heating protection has been triggered. The fuses in the surface s supply group have blown. Check for any foreign objects in the duct system. Once you have found and corrected the fault, the heating surface s over-heating protection must be re-set manually, which is done using the red button on the top of the heating surface. Power to the actual ventilation system will then be disconnected briefly, after which operation can be re-started. Change the fuses. 2 Waterborne Heating Surfaces 2.1 Waterborne after heating surfaces Waterborne after heating surfaces are installed in the supply air side of the duct system. They are used to raise the supply air temperature in order to prevent cold draughts, where air is taken in. The waterborne heating surface is connected to the building s central heating system with both supply and return. The heating surface has a built-in protection against frost burst. A: Extract air. B: Supply air. C: Outdoor air. D: Exhaust air. E: Sensor before heating surface. F: Sensor after heating surface. Note! Supply and return to the surface must be insulated. F + E A B C D Danfoss Heating Solutions VIFKB502 7

8 2.2 Placing a waterborne heating surface The heating surface must be placed at a minimum distance of 500 mm from any component in the duct system (pipe bends, external filters or unit). The heating surface is placed on the supply air side, after the ventilation unit. An arrow on the heating surface indicates the air flow direction. The heating surface is insulated on delivery and does not require any further insulation. The heating surface is designed to be mounted horizontally, but can also be mounted vertically if the heating surface is adequately supported, and if the direction of air flow is upwards. The two factory mounted PT-1000 sensors must be placed in the duct system 50 cm in front of and 50 cm behind the surface. Each sensor is marked if it should be placed before or after surface. If the sensors face the wrong way, the required operations cannot be achieved. Drill Ø8 mm holes in the duct and install the supplied rubber grommets,, then place the sensors into the duct. Fix the sensors to the pipe with duct tape and insulate together with the rest of the duct system and heating surface. Insulation Rubber sleeve PT-1000 sensor 45 mm 2.3 Connecting a waterborne heating surface Connection to the central heating system The waterborne heating surface is connected as shown in the below connection diagram. On delivery, the water heating surface s control valve is fully open and therefore ready for filling, even when switched off. We recommend that you install a dirt trap in the system, and that the shut-off valves be mounted close to the surface to make any subsequent servicing requirements easier. An air-bleed screw must be mounted at the highest point in the system. Fill the system with water and bleed out the air; the surface is then ready for use. Supply and return to the surface should be insulated safely with regard to the frost bursting risk. A: Shut-off valves (recommended). B: PT 1000 sensors mounted in duct. C: Air-bleeding screw (recommended). E D: Circulation pump (central heating system). J A C E: Expansion tank (normally part of the central heating system). F: Any calls for heating are set up with a potential-free relay. D I A G: Heating surface. H: Control valve with motor actuator. F I: Dirt trap. J: Central heating system. Note! Max. flow temp. 85 C, min. differential pressure 0.2 bar, max. differential pressure 4.0 bar, max. pressure level PN 10. B M H G 230 V 50 Hz Electrical connection Once the water heating surface has been filled with water and bled of air, it must be connected electrically. This is done by connecting the supplied power plug to the heating surface and connecting the supplied communication cable between the water heating surface and the ventilation system. 1. Unit. 2. Waterborne heating surface. 3. CCM module. 4. Air Dial. 5. Serial cable, heating surface / unit.. Serial cable, CCM module / unit. 230 V 50 Hz VIFKB502 Danfoss Heating Solutions

9 Mounting sequence - carried out on the serial socket in the unit 1. Twist together in pairs the serial cables with same colour. 2. Crimp-on ferrules are recommended. 3. Insert the cable pairs into the unit connector White / Orange 1 2. Orange 3. Black 4. White / Blue 5. Blue. Remove jumper between terminals 5 and 5. Insert the connector into the unit. Within four minutes the Air Dial will recognise the connected heating surface and automatically register it with the system.. Select which surface must be used, Comfort (constant intake temperature, usually recommended) or Total heating New device found Comfort 2.4 Call for Heating If the central heating system is fitted with weather compensation, it may be advisable to set up a potential-free call for heating. The call for heating is set up from the heating surface s control to the central heating system through a supplementary relay (the control s relay output is not potential-free, and must therefore be taken over an external relay). The heating surface control is located behind the steel plate on the front of the heating surface. A: Modbus. B: Call for heating clamp 27/ V, 4 A (not potential-free). C: Solid state relay. D: External supplementary relay, e.g. Hager 110 ES (not included in the Danfoss delivery). E: Clamps for external calls for heating in the central system. A B C + 2 Note! The electrical heating surface must be installed by a certified electrician. D NO E 230 V Danfoss Heating Solutions VIFKB502 9

10 2.5 Troubleshooting Error indication Reason Solution The surface does not automatically register, when connecting power to the control. The surface does not give off any heat. Air Dial issues a Frost Protection Alarm. When a surface is connected, it can take up to four minutes before it is included in the network. A communication cable has not been connected correctly. The termination resistance is not correctly positioned for the last unit in the chain. Air in the system. There is no hot water from the central heating system. The dirt trap is clogged. Actuator fault. The first time this is connected it could take up to 20 minutes before the valve and the actuator are ready for operation. The control is not calling for heat. Pump fault. Supply air coming out of the unit has a temperature beneath +5 C, before reaching the heating surface. Wait four minutes and check the Air Dial, if any new units have been added to the system. Check if communication cables are mounted correctly and the colour codes between the individual cables are according to this guide. Make sure that a termination resistance is mounted only on the last unit in the system. Bleed the system. Check the central heating system, and possibly set up a Call for Heating. Empty and clean the dirt trap; if necessary, flush the system. Disconnect the actuator and replace with a new (Danfoss AMV 130, no. 082H8037). Wait for minutes until both valve and actuator are ready for operation. The heating surface is not active, if the system is in Away Mode or if the Bypass is activated. Replace the circulation pump. Check that both valves are operational and that air is actually flowing over both circuits. Low temperatures are usually due to an unintentional blockage in the system s duct system. Does the building s central heating work? If the room temperature falls too low, there is no energy for the system to recover and this could also trigger a frost protection. Heat the system again, turn off the alarm on the remote control and switch off power to the ventilation system briefly; the system will then be ready for operation again. Supply air is not warm enough. Flow temperature is too low. Heatpump installations normally operate at low supply temperatures. You should always consider whether this is acceptable before trying to raise the supply temperature (as this often results in worse/more expensive operation of the central heating system). Flow is set too low on the ABQM valve. Flow is too low on the water side. The control is not calling for heat. The valve is supplied with a factory setting of 50% (max. flow = 75 l/h) If this is not enough, e.g. due to large volumes of air combined with a low supply temperature, the actuator can be removed (the union nut is ONLY ever tightened by hand). You now have free access to the control valve, which can be set to a higher value by pulling up the grey plastic collar and then turning it. The current value can be read from the red indicator line on the valve (100% = 150 l/h max. flow). Pressure loss to the surface is too great, or the circulation pump is running too low -> turn up the circulation pump and check that all possible shut-off valves or other throttle organs are fully open. The heating surface is not active if the system is in away mode, or if the bypass is activated. 10 VIFKB502 Danfoss Heating Solutions

11 3 Geothermal Heating Surfaces 3.1 Geothermal heating surfaces A: Extract air. B: Supply air. C: Exhaust air. D: Communication cable. E: Control. F: Power supply to the circulation pump. G: Outdoor air. H1: Sensor T1. H2: Sensor T2. I: Pre-filter (accessory, recommended). J: Condensate drain 3/8 RG A siphon must be mounted, e.g. Danfoss Air water trap (accessory). K: Shut-off valve, not supplied by Danfoss. L: Expansion tank, not supplied by Danfoss. M: Bleeding screw, not supplied by Danfoss. N: Safety valve bar, not supplied by Danfoss. O: Brine filling kit DN 20, contains 2 x shut-off valves, filling and return connectors and dirt trap. Delivered complete and ready insulated (accessory). P: Circulation pump l/h, not supplied by Danfoss. Q: Ground pipe m. A B D C L E H 2 +/- K N M Q H 1 J O P I F G 3.2 Dimensioning of ground collectors Use the table to dimension the necessary pipe length for the installation. You will need to know the air volume and the soil type. The sandier and drier the soil is, the less heat can be drawn from the ground, which is why more pipes need to be laid in this type of soil than in more normal (damper) soil. If you are in any doubt about the type of soil you have, you should allow for sandy soil as the extra cost of laying a couple of additional metres will not make any significant difference to the total installation costs. A: Dry sandy soil (15 W/m²) B: Normal soil (20-30 W/m²) Required pipe length [m] A B 0 [m³/h] Air volume Danfoss Heating Solutions VIFKB502 11

12 3.3 Laying ground collectors Before laying of ground heating pipes, make sure that all necessary permits are obtained from the local building authorities. Beware of other underground installations, such as water pipes, electric cables, gas pipes, sewage lines, etc. Ground collector pipes to be used are Ø40 mm PEL. The pipes are laid at a minimum depth of 1.5 m with a centre-to-centre distance of 1 m. The highest point of the ground collectors circuit must be next to the building so the system can be bled efficiently. Recommended brine: mixed with ethylene glycol or alternatively IPA (spirit) for frost protection to a minimum of -20 C. The illustration shows the laying of pipes in trenches: Centre-to-centre distance min mm Depth min mm The pipes can also be laid in individual tracks (not shown). When leading the ground collectors into the building it is important that the last 1.5 m of ground pipe up to the building is insulated with a porous insulation material (A). The installation must be pressure tested by an authorised installer before commissioning. Note! Supply and return to the surface must be insulated! mm A 1500 mm 3.4 Filling with brine The system should be rinsed and pressure tested with water, before it can be filled with brine. The system is then drained of water and the selected brine is poured in. We recommend that you assemble a filling kit for easy filling and possible draining of the system. Complete, pre-assembled kits can be ordered from Danfoss under part no 08U00 (DN 20). The pump should be set to a flow between l/h, depending on the length of pipe laid (the longer the pipe, the higher the flow). Note! The pump will be powered from the cable from the actual heating surface (pre-mounted). 12 VIFKB502 Danfoss Heating Solutions

13 3.5 Placing a geothermal heating surface The heating surface must be placed at a minimum distance of 500 mm from any component in the duct system (pipe bends, external filters or unit). The heating surface is placed on the outdoor air side, before the ventilation unit. The heating surface is insulated on delivery and does not require any further insulation. Install a Danfoss filter box type FBDU before the geothermal surface to protect it from dirt. An arrow on the heating surface indicates the air flow direction. The heating surface must be mounted horizontally in relation to the condensate drain - check with a spirit level (ill.). A siphon trap must be mounted to the condensate drain (ill.). The two factory mounted PT-1000 sensors must be placed in the duct system 50 cm in front of and 50 cm behind the surface. Each sensor is marked if it should be placed before or after surface. If the sensors face the wrong way, the required operations cannot be achieved (ill.). Drill Ø8 mm holes in the duct and install the supplied rubber grommets,, then place the sensors into the duct. Fix the sensors to the pipe with duct tape and insulate together with the rest of the duct system and heating surface. Rubber sleeve PT-1000 sensor Insulation 45 mm The geothermal heating surface must be mounted horizontally. Siphon trap on condensate drain. Mounting of the PT-1000 sensors. 3. Connecting a geothermal heating surface 1. Unit. 2. Geothermal heating surface. 3. CCM module. 4. Air Dial. 5. Serial cable, heating surface / unit.. Serial cable, CCM module / unit. 7. To circulation pump. 230 V 50 Hz Mounting sequence - carried out on the serial socket in the unit 1. Twist together in pairs the serial cables with same colour. 2. Crimp-on ferrules are recommended White / Orange 1 2. Orange 3. Black 4. White / Blue 5. Blue. Remove jumper between terminals 5 and 5. Insert the connector into the unit. Within four minutes the Air Dial will recognise the connected heating surface and automatically register it with the system New device found 3. Insert the cable pairs into the unit connector. Danfoss Heating Solutions VIFKB502 13

14 3.7 Troubleshooting Error indication Reason Solution The surface does not automatically register, when connecting power to the control. The surface does not give off any heat (winter operation) or does not cool (summer operation). Supply air is not cold enough (summer operations) ¹. When a surface is connected, it can take up to four minutes before it is included in the network. A communication cable has not been connected correctly. The termination resistance is not correctly positioned for the last unit in the chain. Air in the system. Not enough brine is flowing through the system. The control is not calling for heat/ cooling. Air in the system. The flow the pump is supplying is too low. Poor/missing insulation of brine pipes in the building and fresh-air intake for the unit. Wait four minutes and check the Air Dial, if any new units have been added to the system. Check if communication cables are mounted correctly and the colour codes between the individual cables are according to this guide. Make sure that a termination resistance is mounted only on the last unit in the system. Bleed the system. Examine and clean any dirt traps in the system. Check that the pump is running; if necessary turn up the pump. The geothermal surface is normally active at outside temperatures below freezing (pre-heating) and at high outside temperatures during the summer, when cooling is required. In the intervening periods the geothermal surface is often not needed so the pump will not be active at these times. Bleed the system. Check that any valves in the brine circuit are fully open, or turn up the pump. Insulate brine pipes and fresh-air intake to avoid losing cooling performance from the system. ¹ The expected intake air temperature on a summer s day is around C, depending on the length of piping and the soil conditions at the groundworks. 14 VIFKB502 Danfoss Heating Solutions

15 4 Technical Data 4.1 Electrical heating surfaces Type Ø 125 mm Ø 10 mm Ø 250 mm Connection, air Ø 125 mm Ø 10 mm Ø 250 mm Box Galvanised steel plate Galvanised steel plate Galvanised steel plate Max. output 900 W W W Installation Horizontal / upwards Horizontal / upwards Horizontal / upwards Safety thermostat Double, built-in, automatic re-closure at 70 C, manual re-closure at 120 C Double, built-in, automatic re-closure at 70 C, manual re-closure at 120 C Double, built-in, automatic re-closure at 70 C, manual re-closure at 120 C Weight 2.4 kg 3.2 kg 4. kg Length 375 mm 375 mm 375 mm Pressure loss curves for electrical heating surfaces (both pre-heating and after heating surfaces) [Pa] Ø125 Ø10 2 Ø [m3 /h] Danfoss Heating Solutions VIFKB502 15

16 4.2 Waterborne heating surfaces Connection, air Ø 250 mm Connection, water 3/8" RG, nipple Box Highly insulated, fire-resistant EPS shell (U-factor 0.8) Heating effect (winter) 820 W Installation Horizontal Max. water flow (W-AH 250) 150 l/h Weight. kg Dimensions (l x w x h) 00 x 250 x 335 mm Pressure loss curve for the air side [Pa] Pressure loss curve for the water side [KPa] [m 3/h] [l/h] Power output curve for the air side [W] /40/20 50/40/ [m 3 /h] 1 VIFKB502 Danfoss Heating Solutions

17 4.3 Geothermal heating surfaces Connection, air Ø 250 mm Connection, water 3/8" RG, nipple Box Highly insulated, fire-resistant EPS shell (U-factor 0.8) Max. heating surface (400 m³/h, temp. 70/40/20 ) W Heating effect (winter) 820 W Cooling effect (summer) 850 W (actual cooling to room) Installation Horizontal Max. brine flow l/h Weight. kg Dimensions (l x w x h) 00 x 250 x 335 mm Pressure loss curve for the air side [Pa] Pressure loss curve for the brine side [KPa] [m 3/h] [l/h] Danfoss Heating Solutions VIFKB502 17

18 18 VIFKB502 Danfoss Heating Solutions

19 Danfoss Heating Solutions VIFKB502 19

20 Danfoss A/S Heating Solutions Ulvehavevej Vejle Denmark Phone: Fax: heating.solutions@danfoss.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss Heating Solutions and the Danfoss Heating Solutions logotype are trademarks of Danfoss A/S. All rights reserved. VIFKB502 Produced by Danfoss Heating Solutions 05/2012

MAKING MODERN LIVING POSSIBLE. Danfoss Air. Installation guide for Danfoss Heating Surfaces DANFOSS HEATING

MAKING MODERN LIVING POSSIBLE. Danfoss Air. Installation guide for Danfoss Heating Surfaces DANFOSS HEATING MAKING MODERN LIVING POSSIBLE Danfoss Air Installation guide for Danfoss Heating Surfaces DANFOSS HEATING Installation The Danfoss Air system Heating surfaces Index 1.0 Mounting electrical heating surfaces

More information

MAKING MODERN LIVING POSSIBLE. Installation Guide. Danfoss Air Units.

MAKING MODERN LIVING POSSIBLE. Installation Guide. Danfoss Air Units. MAKING MODERN LIVING POSSIBLE Installation Guide www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

MAKING MODERN LIVING POSSIBLE. Technical description DHP-M.

MAKING MODERN LIVING POSSIBLE. Technical description DHP-M. MAKING MODERN LIVING POSSIBLE Technical description www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

MAKING MODERN LIVING POSSIBLE. Danfoss Air Catalogue. Catalogue DANFOSS HEATING

MAKING MODERN LIVING POSSIBLE. Danfoss Air Catalogue. Catalogue DANFOSS HEATING MAKING MODERN LIVING POSSIBLE Danfoss Air Catalogue DANFOSS HEATING Catalogue Danfoss Air units Summary of Danfoss Air The Plug & Play concept ensures a quick installation. Integrated moisture sensors

More information

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10 MAKING MODERN LIVING POSSIBLE Installation Guide SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10 www.eh.danfoss.com Table of Contents 1 Introduction............................................. 3 1.1 Self-limiting

More information

Installation Guide. BasicPlus 2 WT-DR & WT-PR Room Thermostats

Installation Guide. BasicPlus 2 WT-DR & WT-PR Room Thermostats Room Thermostats GB Installation Guide 1. Installation Steps User Guide can be downloaded from: heating.danfoss.com. 1. Installation must be done by an authorised electrician. 2. The room thermostat should

More information

DHP-H Varius Pro+/DHP-L Varius Pro+

DHP-H Varius Pro+/DHP-L Varius Pro+ MAKING MODERN LIVING POSSIBLE www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used

More information

MAKING MODERN LIVING POSSIBLE. Wiring Diagram. DHP-iQ.

MAKING MODERN LIVING POSSIBLE. Wiring Diagram. DHP-iQ. MAKING MODERN LIVING POSSIBLE Wiring Diagram www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

Planning guide. Atec.

Planning guide. Atec. www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.

More information

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 550. Electronic Intelligent Thermostat.

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 550. Electronic Intelligent Thermostat. MAKING MODERN LIVING POSSIBLE Installation Guide ECtemp 550 Electronic Intelligent Thermostat www.eh.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to

More information

MAKING MODERN LIVING POSSIBLE. User Guide. Danfoss Air Units.

MAKING MODERN LIVING POSSIBLE. User Guide. Danfoss Air Units. MAKING MODERN LIVING POSSIBLE User Guide www.heating.danfoss.com The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive 2006/42/EC)

More information

Technical description. Atec.

Technical description. Atec. www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.

More information

Installation Guide. DEVIreg 535. Electronic Thermostat.

Installation Guide. DEVIreg 535. Electronic Thermostat. Installation Guide DEVIreg 535 Electronic Thermostat www.devi.com The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive

More information

MAKING MODERN LIVING POSSIBLE. Installation Guide DHP-M.

MAKING MODERN LIVING POSSIBLE. Installation Guide DHP-M. MAKING MODERN LIVING POSSIBLE Installation Guide www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

Installation Instruction

Installation Instruction Installation Instruction CTS 600 by Nilan VPM 120 VPM 240 VPM 360 VPM 480 VPM 560 Version: 5.02, 17-10-2011 Table of contents Table of contents... 2 Figures... 2 General information before installation...

More information

FHM-Cx Mixing Shunts for Floor Heating

FHM-Cx Mixing Shunts for Floor Heating Data Sheet FHM-Cx Mixing Shunts for Floor Heating Application A self-acting proportional regulator is used to regulate the supply temperature. The regulator ensures that the desired supply temperature

More information

Temperature controller for steam (PN 25) AVT / VGS - external thread

Temperature controller for steam (PN 25) AVT / VGS - external thread Data sheet Temperature controller for steam (PN 25) AVT / VGS - external thread Description The controller has a control valve VGS, thermostatic actuator and handle for temperature setting. Thermostatic

More information

Basic Plus2 Room Thermostats Floor Heating

Basic Plus2 Room Thermostats Floor Heating MAKING MODERN LIVING POSSIBLE User Guide Basic Plus2 Room Thermostats Floor Heating www.heating.danfoss.com The English language is used for the original instructions. Other languages are a translation

More information

FHM-Cx Mixing Shunts for Floor Heating

FHM-Cx Mixing Shunts for Floor Heating FHM-Cx Mixing Shunts for Floor Heating Application Mixing shunt FHM-C5/C6 (UPS pump) The Danfoss compact mixing shunts are used for regulation of flow and supply temperature in hydronic floor heating systems.

More information

Diplomat Inverter/Diplomat Duo Inverter

Diplomat Inverter/Diplomat Duo Inverter www.thermia.com The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive 2006/42/EC) Copyright Thermia Värmepumpar Table of

More information

Installation Guide. Twin Kit 086L1370

Installation Guide. Twin Kit 086L1370 086L1370 Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions. Other languages

More information

Installation and maintenance instructions for cabin units type vertical IDAC (V50)

Installation and maintenance instructions for cabin units type vertical IDAC (V50) GB Installation and maintenance instructions for cabin units type vertical IDAC (V50). Application. Bundled parts. Handling. Marking. Weight. Transport. Storage 5. Installation 5. Mounting 5. Water trap

More information

INSTALLATION GUIDE NZ AU C

INSTALLATION GUIDE NZ AU C DISHWASHER DW60 models INSTALLATION GUIDE NZ AU 591217C 12.17 1 SAFETY AND WARNINGS! WARNING! Electrical shock hazard Before installing the dishwasher, remove the house fuse or open the circuit breaker.

More information

MAKING MODERN LIVING POSSIBLE. User Guide. ECtemp 550. Electronic Intelligent Thermostat.

MAKING MODERN LIVING POSSIBLE. User Guide. ECtemp 550. Electronic Intelligent Thermostat. MAKING MODERN LIVING POSSIBLE User Guide ECtemp 550 Electronic Intelligent Thermostat www.eh.danfoss.com Table of Contents 1 Introduction............... 4 1.1 Safety Instructions........ 5 2 Settings.................

More information

Air heater/cooler in combination with ground source heat pump

Air heater/cooler in combination with ground source heat pump Swegon CASA Air heater/cooler in combination with ground source heat pump Installation, operation and maintenance instructions for design engineers, installation engineers and service personnel SDHWM_c_EN

More information

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Data sheet Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Description STW871 The controllers are: - Type-tested acc. to EN 14597 and protect against exceeding temperatures:

More information

As flexible and logical as you want it. Make the most of your time

As flexible and logical as you want it. Make the most of your time Technical Catalogue for Danfoss Air Ventilation As flexible and logical as you want it. Make the most of your time 3 great reasons to choose Danfoss Air ventilation: Easy installation Comissioning via

More information

Instructions for installation and use English. More documents on: H B /09

Instructions for installation and use English. More documents on:  H B /09 TM Instructions for installation and use English EN More documents on: www.zodiac-poolcare.com H0538700.B - 2015/09 Read this manual carefully before installing, maintaining or repairing this appliance!

More information

Installation instruction

Installation instruction Installation instruction CTS 600 by Nilan VP 18 10P Version: 5.03, 15-04-2011 Contents Contents... 2 List of figures... 2 Before starting... 3 Electrical connection... 4 VP 18-10P installation... 5 Condensation

More information

Installation and user guide Accumulator tanks

Installation and user guide Accumulator tanks Installation and user guide Accumulator tanks Danfoss A/S - VUILB Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language

More information

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½ bit Installation Parts and Tools Parts not Provided Electrical cable Water supply tube Fittings for tube Coupler Teflon tape Air gap Wire nuts for 6-gauge wiring Hose clamp ⅞" UL approved strain relief Electrical

More information

HEAT RECOVERY AIR HANDLING UNIT

HEAT RECOVERY AIR HANDLING UNIT HEAT RECOVERY AIR HANDLING UNIT OPERATION MANUAL KOMFORT_L v2(2)_en.indd 1 07.08.2015 15:0:44 CONTENTS Introduction General Safety regulations Transportation and storage regulations Manufacturer's warranty

More information

Installation Guide. ECL Comfort 210, application A Table of Contents

Installation Guide. ECL Comfort 210, application A Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 4 2.1 Before you start.....................................................

More information

lindab we simplify construction Lindab Modular air handling units Connection, start-up and commissioning manual

lindab we simplify construction Lindab Modular air handling units Connection, start-up and commissioning manual Lindab Modular air handling units Connection, start-up and commissioning manual Connection, start-up and commissioning manual 1 General... 3 2 Warnings and Tips... 3 3 Functional sections... 3 3.1 Fan

More information

INSTRUCTION. Danfoss heating cable mats type 100/150 Danfoss heating cable mats for thin floors. Danfoss heating cable mat type 100/150

INSTRUCTION. Danfoss heating cable mats type 100/150 Danfoss heating cable mats for thin floors. Danfoss heating cable mat type 100/150 INSTRUCTION GB Danfoss heating cable mats type 100/150 Danfoss heating cable mats for thin floors NB! Read page 2 before installing the product if you intend to connect 2 mats to the same thermostat Danfoss

More information

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h PRODUCT DATA COMFORT 40 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 40 m /h COMFORT 40 Product description The Comfort 40 is an energy-efficient ventilation

More information

INSTALLATION AND OPERATING INSTRUCTIONS General operating instructions for sample gas conditioner Model: MAK 6

INSTALLATION AND OPERATING INSTRUCTIONS General operating instructions for sample gas conditioner Model: MAK 6 List of contents 1.0 Uses 2.0 Technical data 2.1 Operating data 2.2 Construction and installation 2.3 Climatic load 2.4 Power supply 3.0 Function and design 3.1 General comments 3.2 Design 3.3 Performance

More information

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h PRODUCT DATA COMFORT 5000 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 5300 m 3 /h COMFORT 5000 The Comfort 5000 is a ventilation unit suitable for central

More information

SonoSelect and SonoSafe energy meters

SonoSelect and SonoSafe energy meters energy meters 03/2016 Danfoss VUIGB402 1 Danfoss A/S DK-6430 Nordborg Denmark CVR nr.: 20 16 57 15 Telephone: +45 7488 2222 Fax: +45 7449 0949 EC/EU DECLARATION OF CONFORMITY Danfoss A/S Danfoss Energy

More information

Xcell 270 Longlife DC wholehouse heat recovery unit

Xcell 270 Longlife DC wholehouse heat recovery unit Xcell 270 Longlife DC wholehouse heat recovery unit Installation and maintenance instructions Xpelair Xcell 270 Longlife DC wholehouse heat recovery unit Xcell 270, Xcell 270BP Please leave this leaflet

More information

VEX100 series Air handling units with cross-flow heat exchanger

VEX100 series Air handling units with cross-flow heat exchanger Product information - Version 6 VEX100 series Air handling units with cross-flow heat exchanger VEX140: 400-2200 m 3 /h VEX150: 700-3600 m 3 /h VEX160: 1100-5000 m 3 /h VEX170: 1400-8400 m 3 /h Contents

More information

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHTS200A EKHTS260A EKHTSP200AA EKHTSP260AA

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHTS200A EKHTS260A EKHTSP200AA EKHTSP260AA INSTALLATION MANUAL Domestic hot water tank for air to water heat pump system EKHTS00A EKHTS60A EKHTSP00AA EKHTSP60AA 6 7 x x x x x x x 0 mm 0 D B >0 C >0 0 >0 A >600 H 0 Ø60 0 0 77 8 6 7 778 6 0 6 6 00

More information

Installation Guide. DEVIreg 534. Electronic Thermostat.

Installation Guide. DEVIreg 534. Electronic Thermostat. Installation Guide Electronic Thermostat www.devi.com Table of Contents 1 Introduction............... 3 1.1 Technical Specifications..... 4 1.2 Safety Instructions........ 6 2 Mounting Instructions.........

More information

Air Comfort. Installation instructions (English) A

Air Comfort. Installation instructions (English) A Air Comfort Installation instructions (English) WWW.BRINKAIRFORLIFE.NL 614788-A This appliance may be used by children as of 8 years of age, persons of reduced mental or physical capacities and those of

More information

Installation Guide. DEVIreg 233. Electronic Thermostat.

Installation Guide. DEVIreg 233. Electronic Thermostat. Installation Guide DEVIreg 233 Electronic Thermostat www.devi.com DEVIreg 233 Table of Contents 1 Introduction............... 3 1.1 Technical Specifications..... 4 1.2 Safety Instructions........ 5 2

More information

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1 Specifications Rated voltage (V) AC 110-120V or 220-240V / 50-60Hz Vacuum motor power consumption(w/hp) 1200 / 1.6 Exhaust water pump power consumption(w/hp 800 / 1.1 Exhaust water pump flow (GPH/LPH)

More information

Partner Valve/High Quality Ball Valve LENO MSV-S

Partner Valve/High Quality Ball Valve LENO MSV-S Partner Valve/High Quality Ball Valve LENO MSV-S Description LENO MSV-S is a partner valve for all manual balancing valves in the LENO family. LENO MSV- S can also be applied as a high quality ball valve.

More information

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing Field of application Description Advantages Range Technical details Installation Remote controls Servicing Remote control ErP * ** Conpliance compliance. ErP ready. Advantages Reversible connections. Ventilation

More information

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 800 m /h COMFORT 00 Product description The Comfort 00 is an energy-efficient ventilation

More information

Technical documentation. ComfoAir XL The latest generation of ventilation units with heat recovery

Technical documentation. ComfoAir XL The latest generation of ventilation units with heat recovery Technical documentation ComfoAir XL 800-6000 The latest generation of ventilation units with heat recovery Heating Cooling Ventilation Filtering Service and recommendations The latest heat recovery range

More information

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter VALLOX Product Code: 3158400 L 3158410 R SILENCER (OPTIONAL) INSTRUCTIONS FOR USE AND MAINTENANCE WATER CIRCULATED POST-HEATING UNIT (OPTIONAL) ELECTRIC POST-HEATING UNIT (OPTIONAL)) PREHEATER (OPTIONAL)

More information

ECO1ZN3P, ECO2ZN4P ECO

ECO1ZN3P, ECO2ZN4P ECO WARNING HOT This product may have hot fluid circulating through it. DO NOT TOUCH! SOME UNION NUTS MAY BECOME LOOSE AND CONSEQUENTLY LEAK THROUGH TRANSPORTATION VIBRATION AND HANDLING. DO NOT OVERTIGHTEN

More information

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 00 m /h COMFORT 00 The Comfort 00 is a ventilation unit suitable for central ventilation

More information

User instructions DHP-AT

User instructions DHP-AT User instructions DHP-AT VUGFC202 If these instructions are not followed during installation and service, Danfoss A/S liability according to the applicable warranty is not binding. Danfoss A/S retains

More information

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A LS Condensate Removal Pump INSTRUCTION MANUAL 6-71-075-115 REVISION A CAUTION: Combustible liquids may not be pumped! The condensate pump may not be run dry, as this can destroy the bearings in a very

More information

PowerVent. Installation manual (GB) English. Store this document in a safe place UK

PowerVent. Installation manual (GB) English. Store this document in a safe place UK PowerVent Installation manual (GB) Store this document in a safe place 959.034.03.UK GB Contents Blz Foreword 3 1. Introduction 3 2. CE declaration 4 3. SAFETY 4 3.1 General 4 3.2 Regulations 4 3.3 Precautions

More information

5, SE GÅNGHESTER,

5, SE GÅNGHESTER, KSUB Control and monitoring unit Valid from week of manufacture 48/2005 Description The KSUB is a control and monitoring unit designed to control various types of fire/smoke dampers and fans in a flexible

More information

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range PRODUCT SELECTION DATA Plug & play unit (built-in control) Class A+ across entire range Classic/Vertical/ceiling-mounted dualflow units High-efficiency heat recovery unit High performance plug fan High-efficiency

More information

DH 100 P. Always Dry dehumidifier. with. Condensation Removal System

DH 100 P. Always Dry dehumidifier. with. Condensation Removal System DH 100 P Always Dry dehumidifier with Condensation Removal System IMPORTANT SAFEGUARD Read all instructions before using this dehumidifier. To reduce the risk of fire, electric shock, or injury to persons

More information

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT S S11 Series SB S11 Series SB -E S11 Series SB -E S11 Series EN OPERATION MANUAL CONTENTS Safety requirements... 2 Purpose... 4 Delivery set...

More information

SonoSelect and SonoSafe energy meters

SonoSelect and SonoSafe energy meters energy meters 02/2016 Danfoss VUIGB302 1 2 Danfoss Energy Meters 2016.02 VUIGB302 Contents 1. Inside the box... 4 2. Installation..............................................................................

More information

EN Z Subject to change due to technical improvements! Operating instructions

EN Z Subject to change due to technical improvements! Operating instructions SOLARTHERMIE - SOLAR THERMAL - SOLAR TÉRMICO - SOLAIRE THERMIQUE Operating instructions Temperature differential controller 3 inputs, 1 output These operating instructions are part of the product. Read

More information

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25 PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and operation instructions Solar stations SolarBloC

More information

Installation and operating instructions. DK energy storage and DK energy buffer

Installation and operating instructions. DK energy storage and DK energy buffer Installation and operating instructions DK energy storage and DK energy buffer Edition: 08-2015 1 Preliminary note With this DK energy storage / DK energy buffer you purchased a DK quality product. The

More information

Installation instruction

Installation instruction Installation instruction CTS 600 by Nilan VPL 15 VPL 15 Top VPL 25 Version: 5.02, 13-05-2011 Table of contents Table of contents... 2 Figure table... 2 Introduction... 3 Power supply... 4 Assembly of VPL

More information

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A cod. 6272262A GENERAL DATA Heating Data Heat Output Input (Adjustable) (Adjustable) Format 34i 11.2 34KW 45 145MJ/hr Format 34e 11.2 34KW 45 145MJ/hr General Specifications FORMAT 34i 34e Main burner injectors

More information

Installation Guide. DEVIreg 330 (-10 to+10 C) Electronic Thermostat.

Installation Guide. DEVIreg 330 (-10 to+10 C) Electronic Thermostat. Installation Guide DEVIreg 330 (-10 to+10 C) Electronic Thermostat www.devi.com Table of Contents 1 Introduction............... 3 1.1 Technical Specifications..... 4 1.2 Safety Instructions........ 5

More information

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300 USER S MANUAL Heat Recovery Ventilator Vents Brig HRV 200 Vents Brig HRV 300 2 Brig HRV 200 (300) CONTENT Introduction... 3 Application... 3 Delivery set... 3 Unit designation key... 4 Basic unit dimensions...

More information

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20 INSTALLATION, OPERATION AND MAINTENANCE Ariterm Hybrid 20 TABLE OF CONTENTS General...3 Installation... 4-5 Dimensions - with flue gas exhauster...6 Dimensions - without flue gas exhauster...7 Pipe installations...8

More information

51AKS I S O OWNER S MANUAL

51AKS I S O OWNER S MANUAL LLOYD'S REGISTER QUALITY ASSURANCE 51AKS I S O 9 00 1 OWNER S MANUAL This manual applies to the following models Stand-alone Split 51AKS 085--- 51AKS 010--- 51AKS 185--- 51AKS 013--- 51AKS 113--- 51AKS

More information

INSTALLATION GUIDE NZ AU

INSTALLATION GUIDE NZ AU DISHWASHER DW60U6I & DW60U2I models INSTALLATION GUIDE NZ AU 1 SAFETY AND WARNINGS 100 lb 45 kg! WARNING! Electrical shock hazard Before installing the dishwasher, remove the house fuse or open the circuit

More information

DEVIreg Opti Electronic Timer Thermostat fulfilling Eco Design Directive

DEVIreg Opti Electronic Timer Thermostat fulfilling Eco Design Directive DEVIreg Opti Electronic Timer Thermostat fulfilling Eco Design Directive www.devi.com Table of Contents 1. Introduction..................................... 2 2. Technical Specifications.........................

More information

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card SOLARTHERMIE - SOLAR THERMAL - SOLAR TÉRMICO - SOLAIRE THERMIQUE - SOLARE TERMICO Installation and operating instructions Temperature difference controller 6 inputs, 3 outputs, integrated data logger for

More information

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control USER S MANUAL Duct heater for supply air pre-heating with external control CONTENTS Contents... 2 Safety requirements... 2 Purpose... 4 Delivery set... 4 Designation key... 4 Technical data... 5 Design

More information

Installation Guide. DEVIreg Touch. Electronic Intelligent Timer Thermostat.

Installation Guide. DEVIreg Touch. Electronic Intelligent Timer Thermostat. Installation Guide DEVIreg Touch Electronic Intelligent Timer Thermostat www.devi.com Table of Contents 1 Introduction............... 3 1.1 Technical Specifications..... 4 1.2 Safety Instructions........

More information

Installation manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta & Clarus Control

Installation manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta & Clarus Control manual W365H, W375H, W305H, W330H, W380H, W3240H, W3300H Exacta & Clarus Control 438 9200-0 06.34 Contents 3 Contents Technical data... :... 2: Transportation and unpacking... 2: Siting and floor... 3:

More information

CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS

CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS Please leave this instruction booklet with the pump as it contains maintenance and safety information (Original Instructions) MODELS This operating manual covers

More information

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE 780EN www.caleffi.com Recess Mounted Heat Interface Unit - SATK series SATK0-60 series INSTRUCTIS FOR INSTALLATI, COMMISSIING AND MAINTENANCE Function The SATK series HIU allows independent control of

More information

ELECTRIC BOILERS FOR CENTRAL HEATING

ELECTRIC BOILERS FOR CENTRAL HEATING ELECTRIC BOILERS FOR CENTRAL HEATING TermoMax INSTRUCTIONS FOR INSTALLATION INSTRUCTIONS FOR INSTALLATION We reserve the right of alternations WE ARE NOT LIABLE FOR DAMAGES RESULTING FROM NON- OBSERVING

More information

CFS-2000 CHILLER TM. Operating Instructions P/N (110 VAC) P/N (230 VAC)

CFS-2000 CHILLER TM. Operating Instructions P/N (110 VAC) P/N (230 VAC) CFS-2000 CHILLER TM Operating Instructions P/N 100100 (110 VAC) P/N 100105 (230 VAC) Thank you for purchasing this CFS-2000 CHILLER TM! As you will notice from the table of contents, the manual for your

More information

VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails

VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails Application VHX floor connection VHX wall connection The VHX-sets are specially designed for towel rails and designer

More information

DXR 230 PREMIUM. dx system INSTALLATION AND MAINTENANCE INSTRUCTION (ENGLISH VERSION)

DXR 230 PREMIUM. dx system INSTALLATION AND MAINTENANCE INSTRUCTION (ENGLISH VERSION) INSTALLATION AND MAINTENANCE INSTRUCTION (ENGLISH VERSION) dx system DXR 230 PREMIUM Heat recovery unit with demand control for ceiling installation - Apr.2016 2 / 32 1. Introduction 3 1.1. Warnings 3

More information

Installation, operation and care. Pellmax UB. Burner not included Replaces:

Installation, operation and care. Pellmax UB. Burner not included Replaces: Installation, operation and care Burner not included 2011-11-11 ver: Replaces: Contents 11.11 otes...3 General...4 Function...4 Technical data...5 System principle Pellmax with radiator and tank-in-tank

More information

Zehnder ComfoInline Heater

Zehnder ComfoInline Heater Zehnder ComfoInline Heater Specifications and Installation Guidelines This unit complies With CSA and UL SDHR5-1.5K120V1P-CIRO17-OTDD-OEMZ standards SDHR6-2.5K220V1P-CIRO17-OTDD-OEMZ SDHR7-3.5K220V1P-CIRO17-OTDD-OEMZ

More information

Air handling unit. BlauAir RH USER S MANUAL

Air handling unit. BlauAir RH USER S MANUAL Air handling unit EN USER S MANUAL CONTENTS Safety requirements... 2 Purpose... 4 Delivery set... 4 Designation key... 4 Technical data... 5 Unit design and operation logic... 7 Installation and set-up...

More information

Swedish design and manufacture since 1967

Swedish design and manufacture since 1967 Swedish design and manufacture since 167 PVP MA20-14 rev.2 Manual User manual Copyright 2017 Pahlén AB, Box 728, SE-14 27 Upplands Väsby, Sweden Tel. +46 8 54 110 50, Fax +46 8 50 868 80, e-mail: info@pahlen.se,

More information

TECHNICAL INFORMATION Touchtronic Clothes Dryers

TECHNICAL INFORMATION Touchtronic Clothes Dryers TECHNICAL INFORMATION Touchtronic Clothes Dryers Includes: T1302, T1303, T1322, T1329ci T1403 & T1405 2004 Miele This page intentionally left blank. Table of Contents GENERAL INFORMATION A. Warning and

More information

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit DC Heat Recovery Unit MVHR Wholehouse heat recovery unit Stock Ref. N DC Heat Recovery Unit MVHR 443423 Installation, Maintenance & Users Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

More information

PORTABLE AIR CONDITIONER (LOCAL)

PORTABLE AIR CONDITIONER (LOCAL) EN PORTABLE AIR CONDITIONER (LOCAL) OPERATING INSTRUCTIONS Read the instructions carefully before operating the appliance or carrying out maintenance work. Observe all the safety instructions; failure

More information

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 130. Electronic Thermostat.

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 130. Electronic Thermostat. MAKING MODERN LIVING POSSIBLE Installation Guide ECtemp 130 Electronic Thermostat www.eh.danfoss.com Table of Contents 1 Introduction............... 3 1.1 Technical Specifications..... 4 1.2 Safety Instructions........

More information

Swegon Home Solutions CASA. W9 Smart. Installation, commissioning and maintenance instruction. W9_e_EN-t

Swegon Home Solutions CASA. W9 Smart. Installation, commissioning and maintenance instruction. W9_e_EN-t Swegon Home Solutions CASA W9 Smart Installation, commissioning and maintenance instruction W9_e_EN-t Contents Installation, operation and maintenance instructions for design engineers, installation engineers

More information

Weather compensated flow temperature control of heating and boiler systems

Weather compensated flow temperature control of heating and boiler systems Instructions ECL Comfort 110 Application 130 Weather compensated flow temperature control of heating and boiler systems User guide, Installation & Maintenance DH-SMT/DK VI.KT.G3.02 Danfoss 06/2008 How

More information

Installation Guide. DEVIreg Smart. Intelligent Electronic Timer Thermostat with Wi-Fi connectivity and App control.

Installation Guide. DEVIreg Smart. Intelligent Electronic Timer Thermostat with Wi-Fi connectivity and App control. DEVIreg Smart Intelligent Electronic Timer Thermostat with Wi-Fi connectivity and App control www.devi.com Table of Contents 1 Introduction................... 2 2 Technical Specifications............ 4

More information

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm Safety instructions The washing machine is heavy - take care when lifting. Caution: frozen hoses may rip/burst. Do not install the washing machine in areas exposed to frost or outdoors. The washing machine

More information

Installation Guide. DEVIreg Smart. Intelligent Electronic Timer Thermostat with Wi-Fi connectivity and App control.

Installation Guide. DEVIreg Smart. Intelligent Electronic Timer Thermostat with Wi-Fi connectivity and App control. DEVIreg Smart Intelligent Electronic Timer Thermostat with Wi-Fi connectivity and App control www.devi.com Table of Contents 1 Introduction................... 2 2 Technical Specifications............ 4

More information

Hoffman Controls 759-ECM. Installation & Operating Instructions. Introduction. Installation. Pre-Installation Information/ Instruction

Hoffman Controls 759-ECM. Installation & Operating Instructions. Introduction. Installation. Pre-Installation Information/ Instruction Hoffman Controls Installation & Operating Instructions Introduction CAUTION Failure to read and understand the accompanying instructions and diagrams prior to energizing the Controller may result in permanent

More information

IMPORTANT SAFETY INSTRUCTIONS DANGER: WARNING:

IMPORTANT SAFETY INSTRUCTIONS DANGER: WARNING: IMPORTANT SAFETY INSTRUCTIONS YOUR SAFETY AND THAT OF OTHERS IS PARAMOUNT This manual and the appliance itself provide important safety warnings, to be read and observed at all times. This is the attention

More information

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

VMA-VMB NOVA AIR HEATERS. NoVa air heaters VMA-VMB NOVA AIR HEATERS NoVa air heaters PRODUCT FACTS PRODUCT The Novenco NoVa air heaters are water-based units with hot-water heating coils and axial flow fans fitted in cabinets. VMA for 10-20 C cooling

More information

Cooker Hood User Manual

Cooker Hood User Manual Cooker Hood User Manual HCB93042X EN 01M-8850803200-0116-02 Please read this manual first! Dear Customers! Thank you for preferring a Beko product. We hope that you get the best results from your product

More information

Fits into compatible switch frames from manufacturers such as Busch-Jaeger, Gira, Berker and Merten.

Fits into compatible switch frames from manufacturers such as Busch-Jaeger, Gira, Berker and Merten. Hydronic floor heating control Danfoss Icon Room thermostats made to match your switch frames Advanced room controls for hydronic floor heating and other applications with actuators. Fits into compatible

More information