Refrigeration Supplies

Size: px
Start display at page:

Download "Refrigeration Supplies"

Transcription

1 Section 11 Refrigeration Supplies INDEX Refrigerant R-410A HOT-SHOT by ICOR NU-22b by ICOR Recovery Service 11-2 Recovery Tanks Certification Supplies Filter Driers Acid Test Kits 11-3 Valve Cores Saddle Tap Valves Controls Fan Cycle Switches Low Pressure Switches 11-4 Thermal Expansion Valves Compressors Replacement Compressors Service Ready Parts

2 Refrigeration Supplies REFRIGERANT R22 or HCFC-22 is a single component HCFC refrigerant. Used in a wide variety of residential and commercial applications. R-410A: A blend of R-32 and R-125. This blend has about 60% higher pressure than in air conditioning applications, and therefore should be used only in new equipment specifically designed to handle the pressure. R-410A will require POE lubricants. Retrofitting equipment with R410A is not recommended under any circumstances. REFRIGERANT - REPLACEMENT Direct Replacement For:, R-407C, and R-417A. NU-22B closely mimics the operating characteristics of, making it the high-performance choice for both OEM and service replacement uses. No complications, no expensive retrofits. You won t need any product-specific tools or supplies to use NU-22B. It s compatible with all standard oils and all standard equipment components and materials used in systems. CSI # Description Size Price MUST PRESENT EPA CARD TO PURCHASE 901-NU-22B NU-22B (R22 DROP IN) - 25# CYLINDER CSI # Type Size Price REFRIGERANT RECOVERY 901-R22 30 # Cylinder R410A R # Cylinder R22 Phase out schedule: January 1st, 2010 No new R22 can be manufactured for new HVAC equipment (i.e. Air Conditioners or Heat Pumps.) January 1st, 2020 No gas can be manufactured or imported into the United States. Direct Replacement For: R-12, R-500, R-134a Simple and easy to use refrigerant recovery service. Simply bring in your full generic recovery cylinders and swap them with an empty one. One simple and easy ID tag to fill out on your return cylinder, Special cylinders / large size cylinders can be processed and returned. 914-CPFS-30 30LB CYLINDER SWAP REFRIGERANT - HOT SHOT 914-CPFS-50 50LB CYLINDER SWAP Hot Shot, R-414B is environmentally, Economically and Technically superior to any other refrigerant in the market today. Hot Shot is the best alternative. R-414B is UL classified, has a nontoxic, nonflammable safety classification. - Fully Compatible with all standard refrigerant lubricants. - No oil changes required at any temperature application. - Near duplication of R-12 characteristics. - No expensive parts retrofits. - 8% more efficient than R-12 - EPA accepted for use in both stationary ALSO REPLACES: R-401A, R409A, R-420A, R-401B, R-416A Recovery Cylinders Meets DOT / OSHA Standards 914-RC30 30LB CYLINDER RC50 50LB CYLINDER EPA REFRIGERANT CERTIFICATION Self-Study Course and mobile equipment EPA approved test for Type I,II,III, and Universal - Receive your EPA Certification card, - Test Course SECTION (Required to work with R22) material is presented quickly and easily - Price includes EPA certification test and card HOTSHOT HOTSHOT (R12 DROP-IN)-25# T-TEST 608 EPA CERTIFICATION TEST- R NEED TECHNICAL ASSISTANCE ON ANY REFRIGERATION RELATED ISSUE? 950-T-608PM EPA PREPARATORY MANUAL T-608CD AUDIO CD OF PREP MANUAL R410A - (Volutary) Tech2Tech 950-T-410A R-410A CERTIFICATION EXAM TECH This service is provided by ICOR International, manufacturers of NU-22, HOT SHOT, and ONE SHOT 950-T-410APM R410A SAFETY & TRAINING MANUAL T-CD410A R-410A INTERACTIVE TRAINING CD

3 STOP throwing away your empty refrigerant cylinders, and START participating in our cylinder disposal program. We are now accepting any size and any type of used refrigerant cylinders at NO COST. Refrigeration Supplies ACID TEST - QWIKCHECK Fast, accurate, and easy to use, QwikCheck provides an early warning of acid problems. The Yellow to Red color change allows you to easily and clearly communicate the need for action to the equipment owner 950-QT2000 QWIKCHECK ACID TEST KIT FILTER DRYERS - LIQUID LINE Filter driers are specifically designed to protect the refrigerant system from liquid and solid contaminants. They incorporate a desiccant specially blended and molded in block form. VALVE CORES R22 & R410 Rated 731-AF2100 MA-LINE 1/4" VALVE CORES - 5PK 5.23 CSI # Size AC Tons Price VALVE CORE TOOL W/CORES S 3/8" SWEAT S 3/8" SWEAT S 3/8" SWEAT FILTER DRYERS - BI FLOW Designed for heat pump installations. Internal check valves allow flow and filtration in either direction. Filter driers are specifically designed to protect the refrigerant system from liquid and solid contaminants. They incorporate a desiccant specially blended and molded in block form. R22 & R410 Rated CSI # Size AC Tons Price 731-AF2200 MA-LINE 1/4" VALVE CORE TOOL 6.92 COPPER TUBE EXTENSIONS 910-BF083S 3/8" SWEAT BF163S 3/8" SWEAT ACCESS FTG 1/8"OD TUBE - 5PK ACCESS FTG 3/16"OD TUBE - 5PK FILTER DRYERS - SUCTION LINE ACCESS FTG 1/4"OD TUBE - 5PK The SLED Series is a solid core clean-up filter-drier for use in the suction line.the compact design incorporates a large outside diameter shell, which results in a shorter lay-in length, and a larger core, which provides a greater filtration area for maximum operating efficiency. CSI # Size AC Tons Price ACCESS FTG 3/8"OD TUBE - 5PK COPPER SADDLE TAP VALVE These saddle taps are designed to allow the addition of an access port without the need to evacuate the system. Solder/Braze the saddle to the existing line and then use the unique design to pierce the line. Perfect for adding pressure switches, or service access. 910-SLD08-5SV 5/8" SW 3.9 #N/A 910-SLD13-6SV-HH 3/4" SW STV12 # VLC-8 1/2" SADDLE TAP VALVE SSSLD16-6SV 3/4" SW STV34 # VLC-12 3/4"SADDLE TAP VALVE SLD13-7SV-HH 7/8" SW STV38 # VLC-6 3/8" SADDLE TAP VALVE SLD27-7SV 7/8" SW STV58 # VLC-10 5/8"SADDLE TAP VALVE

4 FAN CYCLE SWITCH Encapsulated pressure switch is designed to cycle condenser fan in low ambient operation. 1/4" female flare connection 18" leads Refrigeration Supplies THERMAL EXPANSION VALVE EXPANSION VALVES Non- Adjustable Internal Check Valve External Equalizer 1/4" Bleed Hole CSI # Cut In Cut Out Price Includes Suction Line Elbow with Port 454-P100AP PARKER HCE SERIES LOW PRESSURE SWITCH CSI # Tons Type System Price Encapsulated pressure switch 1/4" female flare connection 18" leads 109-H2TXV01 Up to 3.0 Bleed AC & HP H2TXV02 Up to 5.0 Bleed AC & HP H2TXV03 Up to 6.0 Bleed AC & HP CSI # Open Close Price 454-PS-LP REFRIGERATION OIL AC / HP COMPRESSORS Capitol Supplies stocks large number of Copeland replacement compressors from Service Ready Parts warranty division. These compressors are perfect replacement s for out of warranty compressors as well. Call our sales department for more information. LineSeal HVACR Affordable and easy eay to repair small leaks in refrigerant lines & coils 337-5GS REFRIGERATION OIL-1 GAL-525VIS THERMAL EXPANSION VALVE EXPANSION VALVES Non- Adjustable Internal Check Valve Equalizer Bleed Hole Permanently seals leaks in condensers, evaporators, and linesets. / Can be used with all oils and refrigerants / Included hose and valve assembly CSI # Tons Type Equalizer System Price 101-X3-3 Upto 3.5 Bleed External AC & HP #N/A 101-X Bleed External AC & HP #N/A THERMAL EXPANSION VALVE KIT LINE SEAL HVACR-1.5 TO 5.0 T EXPANSION VALVES Non- Adjustable Internal Check Valve External Equalizer 1/4" Bleed Hole LIQUID LINE SIGHT GLASS Sight Glass with moisture indicator. Easily check system status. 3/8" for common residential / light commerrcial split systems. PARKER HCE SERIES CSI # Tons Type System Price 454-HCAE3VX100A Upto 3.0 Bleed AC & HP SITGLS-38 3/8" Liquid Line Sight Glass

5 Refrigeration Supplies PISTON ORIFICE FIXED OPENING METERING DEVICE PRO-FLUSH System Flush Used for R22 to R410 system conversion R22 & R410A SYSTEMS Includes removal hook and teflon seal ring. PRO-Flush as been formulated to provide a flushing agent for HFC systems that is still ozone safe, biodegradable and non-carcinogenic. PRO-Flush effectively removes impurities including oil, sludge, acid and moisture. PRO-Flush is a must for system clean ups and retrofits. CSI # Orifice Size Price W82 PISTON KIT W83 PISTON KIT W85 PISTON KIT W86 PISTON KIT Flushes moisture, oil, acid, and impurities Flushes more oil than R-11 - Absorbs more acid & water than R-11 - Safe for all refrigerants & oils - Flush systems after burn-outs - Flush systems for HCFC to HFC refrigerant conversions Hooks up to your NITROGEN TANK RIG. NITROGEN pushes the FLUSH thru the lineset W87 PISTON KIT W88 PISTON KIT W89 PISTON KIT PFKIT PRO-Flush Kit - Refillable tank, charging hose W91 PISTON KIT flush nozzle, 16 oz Pro-Flush, pres. Relief valve W93 PISTON KIT PF16 PRO-Flush 16 oz refill W95 PISTON KIT W96 PISTON KIT QWIK SYSTEM FLUSH W99 PISTON KIT SELF PRESSURIZED LINSET FLUSH W00 PISTON KIT W01 PISTON KIT W04 PISTON KIT W06 PISTON KIT W08 PISTON KIT W14 PISTON KIT W15 PISTON KIT SERVICE VALVES 337-QT1100 QWIK SYSTEM FLUSH QT QT CSI # SIZE STYLE Price 337-QT QT R /8" 90 DEG R /4" 90 DEG R /8" 90 DEG Since Capitol Has It! 110-R /8" STRAIGHT R /4" STRAIGHT /8" STRAIGHT

6 NOTES 11-6

Residential Piping and Long Line Guideline

Residential Piping and Long Line Guideline AC / HP R-410A Refrigerant Systems Single-Stage, Two-Stage and Variable Speed Models Residential Piping and Long Line Guideline TABLE OF CONTENTS Safety Considerations... 2 Definitions... 2 Introduction...

More information

Harold Ag & Mobile Products

Harold Ag & Mobile Products TM Harold Ag & Mobile Products Your Ag A/C Parts Specialist 1-800-541-8910 www.heco.net R E F R I G E R A N T S 6-18-13 FR-12 COMPARED TO OTHER BLENDS UL Classified A1/A1 (non-flammable!) ASHRAE Listed

More information

REFRIGERATION PRODUCTS

REFRIGERATION PRODUCTS SE REFRIGERATION PRODUCTS Smart Electric products offer reliable and longer lasting solutions for refrigeration. We know how important it is to keep systems clean and running at its full efficiency for

More information

Accumulators - Suction Line

Accumulators - Suction Line ACCUMULATORS Accumulators - Suction Line kw Cap at Evap. Temp. -6 C Size Connection R22 R404A / R507C F0804 1/2" ODS Vertical 4.6 4.8 F0805 5/8" ODS Vertical 6.9 7.2 F0806 3/4" ODS Vertical 9.2 9.6 F0807

More information

The complete approach to the care and management of A/C & refrigeration systems

The complete approach to the care and management of A/C & refrigeration systems The complete approach to the care and management of A/C & refrigeration systems Testing oil with the Phase III Refrigeration Oil Acid Test Kit Flushing with OEM endorsed R x 11-flush Acid removal with

More information

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

Some of these procedures need to be performed to conform to requirements of the Clean Air Act. Leak Detection, Recovery, Evacuation and Charging Four basic service procedures used to repair and maintain a mechanical refrigeration system are leak detection, evacuation, recovery, and refrigerant charging.

More information

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery. HET- 190 ESL Support page 1 CORE Basic Refrigeration Circuit 1. Liquid refrigerant boils in the evaporator. Heat is absorbed. The heat energy absorbed converts refrigerant liquid into vapor. 2. Refrigerant

More information

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS Refrigerant R22 is widely used for residential and commercial air conditioning, as well as commercial refrigeration

More information

The natural solution for domestic refrigeration

The natural solution for domestic refrigeration The natural solution for domestic refrigeration 1300 492 445 info@hychill.com.au Minus 10 is a high-purity R600a (isobutane), the dominant single-ingredient refrigerant used in state-of-the-art light commercial

More information

R E D I C O N T R O L S

R E D I C O N T R O L S R E D I C O N T R O L S File Literature Number 1144-01-1 Installation Operation & Maintenance Manual CONTINUOUS REFRIGERANT DEHYDRATOR Model: CD-120 For use with Refrigerants R-11, R-123, R-12, R-22, R-134a

More information

Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A. Leading the Industry with Environmentally Responsible Refrigerant Solutions Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A Leading the Industry with Environmentally Responsible Refrigerant Solutions Emerson Climate Technologies, Inc. does not advocate

More information

Refrigerant changeover guidelines

Refrigerant changeover guidelines Refrigerant changeover guidelines HCFC R-22 to HFC R-407A/F, R-448A or R-449A for medium and low temperature applications HCFC R-22 to HFC R-407C for high, medium and low temperature applications HCFC

More information

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system Core 1. Ozone in the stratosphere above the earth consists of: a. Molecules containing 3 oxygen atoms. b. Molecules of 2 oxygen atoms. c. Radioactive particles. d. Pollutants that have risen from ground

More information

Sealed Type Liquid Line and Suction Line Specifications

Sealed Type Liquid Line and Suction Line Specifications CATALOG 0 Page,, 4a, 404A, 407C, 40A, 0, 07 Also Compatible with Refrigerants, 4,, 40A & B, 40A & B, 408A, 409A The universal acceptance of the Catch-All Filter-Drier is due to its unique molded porous

More information

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system Core 1. Ozone in the stratosphere above the earth consists of: a. Molecules containing 3 oxygen atoms. b. Molecules of 2 oxygen atoms. c. Radioactive particles. d. Pollutants that have risen from ground

More information

FSW. Product guide. Driers and Sight Glasses CSECTION For more information visit

FSW. Product guide. Driers and Sight Glasses CSECTION For more information visit FSW Product guide CSECTION Driers and Sight Glasses For more information visit www.fsw.uk.com 47 Copper Spun Driers Suitable for HFC, CFC and HCFC. CODE MODEL SIZE CONNECTIONS C440 MSCD-5-3 5 Gram 3/16"

More information

Installation Instructions

Installation Instructions Installation Instructions B-Series VT40, VT60, VT100 Important Safety Notice. This information is intended for use by individuals possessing adequate backgrounds of electrical, refrigeration and mechanical

More information

Air Conditioning Operation and Troubleshooting Matt Dunham

Air Conditioning Operation and Troubleshooting Matt Dunham Air Conditioning Operation and Troubleshooting Matt Dunham Major Components (10 Minutes) Compressor heart of the system, causes refrigerant to flow by increasing the pressure of the refrigerant Metering

More information

Motor Vehicle Air Conditioning (MVAC) System operation and the refrigerant cycle

Motor Vehicle Air Conditioning (MVAC) System operation and the refrigerant cycle Motor Vehicle Air Conditioning (MVAC) System operation and the refrigerant cycle At Sea level water boils at 212⁰ F R 134a boils at 15⁰ F At Sea level R 134a boils at 15⁰ F At 30 psig R 134a boils at 35⁰

More information

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS INTRODUCTION Please note that HUD Manufactured Home Construction and Safety Standard Section 3280.714, paragraph (a) and subparagraph

More information

The Changing State of Refrigerants. Gary Parker Refrigerants Product Manager

The Changing State of Refrigerants. Gary Parker Refrigerants Product Manager The Changing State of Refrigerants Gary Parker Refrigerants Product Manager The Changing State of Refrigerants Acronyms you may want to know CARB California Air Resources Board GWP Global Warming Potential

More information

REFRIGERANT CHANGEOVER

REFRIGERANT CHANGEOVER Date of last update: Dec-17 Ref: CC7.26.5/0117-1217/E Application Engineering Europe REFRIGERANT CHANGEOVER FROM HFC R134a TO HFC/HFO R450A & R513A WARNING Use only Emerson approved refrigerants and lubricants

More information

NZQA Expiring unit standard 3397 version 4 Page 1 of 5. Convert an automotive air conditioning system from R-12 to R-134a

NZQA Expiring unit standard 3397 version 4 Page 1 of 5. Convert an automotive air conditioning system from R-12 to R-134a Page 1 of 5 Title Convert an automotive air conditioning system from R-12 to R-134a Level 3 Credits 2 Purpose This unit standard is for people in the automotive repair industry. People credited with this

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MODEL LV20 LARGE CAPACITY REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 R01101 LV20.DOC NRP-OM-LV20

More information

Precise Temperature Control; Compact Footprint

Precise Temperature Control; Compact Footprint Precise Temperature Control; Compact Footprint The Conair EP1 Series Portable Chillers are designed for 1 to 3 ton applications. Available as air-cooled or water-cooled, with pump sizes from 1/4 to 3 Hp

More information

ENERGY EFFICIENCY PERFORMANCE SAVINGS SERVICE MANUAL R-290

ENERGY EFFICIENCY PERFORMANCE SAVINGS SERVICE MANUAL R-290 hydrocarbon ENERGY EFFICIENCY PERFORMANCE SAVINGS SERVICE MANUAL R-290 974280 INDEX Why R-290... 1 Best Alternative... 2-3 FAQ... 4-7 Labeling... 8-10 The Difference in R-290 vs. R-134a/R-404A... 11-17

More information

Filter Driers with Replaceable Core

Filter Driers with Replaceable Core STANDARD Filter Driers with Replaceable Core The filter driers with replaceable core (HTG series) are used in liquid line and suction line of refrigerating, freezing and air conditioning system. The filter

More information

4/19/2013. The Changing State of Refrigerants

4/19/2013. The Changing State of Refrigerants 4/19/2013 The Changing State of Refrigerants Refrigerant Chemistry CFC = Chlorofluorocarbon Rapid phase-out Stopped U.S. production in 1996 R-11, R-12, R-113, R-114, R-500, R-502 HCFC = Hydrochlorofluorocarbon

More information

LEADERS IN LIQUID SCIENCE.

LEADERS IN LIQUID SCIENCE. LEADERS IN LIQUID SCIENCE. LEADERS IN LIQUID SCIENCE. INDEX CHEMICAL TOOLS SUPER SEAL ADVANCED SUPER SEAL TOTAL SUPER SEAL ULTRA DRY R FLASH SUPER SEAL AUTOMOTIVE LEAK DETECTION FLASH FLASH UV LEAK DETECTION

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MODEL LV8 COMMERCIAL REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 A01001 7/11/96 NRP-OM-LV8 7/96

More information

Refrigerant Recovery Unit, Model RRU134

Refrigerant Recovery Unit, Model RRU134 Installation, Operation & Maintenance Manual IOMM RRU134 Group: Refrigerant Effective: December 2000 Supersedes: New Refrigerant Recovery Unit, Model RRU134 1999 McQuay International Table of Contents

More information

Installation Instructions

Installation Instructions 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons Installation Instructions Fig. 1-24AHA4 A07532 SAFETY CONSIDERATIONS Improper installation, adjustment, alteration,

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MODEL RLV-700 REFRIGERANT RECOVERY / RECYCLING UNIT (PATENTED) NATIONAL REFRIGERATION PRODUCTS 985 Wheeler Way Langhorne, PA 19047 (215) 638-8909 FAX (215) 638-9270 REVISED 03-21-2018

More information

OWNER S MANUAL (English)

OWNER S MANUAL (English) TRS600 IGNITION PROOF SERIES Refrigerant Recovery Machines OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS600, TRS600K, TRS600S Evaluated for performance

More information

Operation and Maintenance Manual

Operation and Maintenance Manual Warranty Information Ritchie Engineering guarantees YELLOW JACKET products to be free of defective material and workmanship which could affect the life of the product when used for the purpose for which

More information

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual RecoverX Oil-Filled Hermetic Refrigerant Recovery System Operation and Maintenance Manual Table of Contents Page General Safety Instructions 2-3 System Overview 3 Operating Guide 4 Restart Procedure 4

More information

RED DOT UNITS. Heating & Air Conditioning. Parts

RED DOT UNITS. Heating & Air Conditioning. Parts Heating & Air Conditioning Parts 71 R-134a COMPONENTS THE DETAILS R-134a is the new refrigerant that will be used in future heavy duty air conditioning systems. This new refrigerant is used in conjunction

More information

Copeland Scroll Condensing Units for the Food Service Market

Copeland Scroll Condensing Units for the Food Service Market Copeland Scroll Condensing Units for the Food Service Market...with Best In Class Emerson System Protection Components Medium and Low Temperature Refrigeration Applications R-404A 1.5 to 10 Hp Reliable

More information

SOLUTIONS TO KEEP IT COOL

SOLUTIONS TO KEEP IT COOL SOLUTIONS TO KEEP IT COOL Cool Air Products has the safest, most innovative, smartest solutions in the market. Cool Air Products was founded with the concept of manufacturing revolutionary products that

More information

Fluid Exchange. Refrigerant Handling Systems Recovery/Recycling Systems Fluid Exchangers Flushers Fluid Exchange Accessories BUYER'S GUIDE

Fluid Exchange. Refrigerant Handling Systems Recovery/Recycling Systems Fluid Exchangers Flushers Fluid Exchange Accessories BUYER'S GUIDE Fluid Exchange Refrigerant Handling Systems Recovery/Recycling Systems Fluid Exchangers Flushers Fluid Exchange Accessories 423 ASCOT 424 Refrigerant Recovery/Recycling Systems Recovery and Recycling Systems

More information

HVACR Refrigeration

HVACR Refrigeration Western Technical College 10601101 HVACR Refrigeration Course Outcome Summary Course Information Description Career Cluster Instructional Level Total Credits 4.00 Total Hours 108.00 This course is an introduction

More information

AUTOMOTIVE SPECIALIZATION (Air Conditioning and Heating) STUDENT GRADE RECORD Career & Technical Education

AUTOMOTIVE SPECIALIZATION (Air Conditioning and Heating) STUDENT GRADE RECORD Career & Technical Education STUDENT GRADE RECORD Career & Technical Education Course Outline Modules Windham Module Test Module Competenc y Rating WINDHAM SCHOOL DISTRICT 1. CTE Orientation 2. Introduction to Automotive Heating,

More information

TRS21 IGNITION PROOF SERIES

TRS21 IGNITION PROOF SERIES TRS21 IGNITION PROOF SERIES 2 Cylinder Commercial Recovery Machine OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS21, TRS21C, TRS21S Evaluated for

More information

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration Calhoon MEBA Engineering School Study Guide for Proficiency Testing Refrigeration 1. To prevent an injury when working with refrigerants, what safety precautions are necessary? 2. When halogens are in

More information

Auto Service Test Review. For the Most Effective Personal Review, Match the Following Questions to the On Line Study Guide Multimedia

Auto Service Test Review. For the Most Effective Personal Review, Match the Following Questions to the On Line Study Guide Multimedia Auto Service Test Review For the Most Effective Personal Review, Match the Following Questions to the On Line Study Guide Multimedia Auto Service Test Review Test #3 73 Questions from: Chapters 39 & 40

More information

INSTALLATION, OPERATION, SERVICE & PARTS SUPPLEMENT for

INSTALLATION, OPERATION, SERVICE & PARTS SUPPLEMENT for T-333 Manual INSTALLATION, OPERATION, SERVICE & PARTS SUPPLEMENT for Rooftop Energy Storage Systems (ESS) AIR COOLING UNIT 77-62186-00 THRU -04 & 77-62203-00 T-333 REV. 03/2012 2012 Mobile Climate Control

More information

REFRIGERANT RECOVERY SYSTEMS

REFRIGERANT RECOVERY SYSTEMS REFRIGERANT RECOVERY 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com RECOVERY YELLOW JACKET HVAC&R HOSES YELLOW JACKET YJ-LTE Refrigerant

More information

Air Conditioners (Outdoor)

Air Conditioners (Outdoor) 22/04/16 A1 Air Conditioners (Outdoor) Outdoor Condenser Units - R-410A Refrigerant Split System Air Conditioners, 208/230 Volt, Single Phase Copeland Scroll Compressor Micro-channel all aluminum coils

More information

AUTOMOTIVE HEATING AND

AUTOMOTIVE HEATING AND AUTOMOTIVE HEATING AND AIR CONDITIONING SIXTH EDITION Tom Birch Prentice Hall Boston Columbus Indianapolis New York San Francisco Upper Saddle River Amsterdam Cape Town Dubai London Madrid Milan Munich

More information

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M 2004 Lennox Industries Inc. Dallas, Texas KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04 Supersedes 503,249M Litho U.S.A. COMPRESSOR REPLACEMENT KIT INSTALLATION INSTRUCTIONS FOR COMPRESSOR

More information

SANHUA S OFFER FOR REFRIGERATION APPLICATIONS

SANHUA S OFFER FOR REFRIGERATION APPLICATIONS SANHUA S OFFER FOR REFRIGERATION APPLICATIONS Strive for perfection, Pursuit of excellence Sanhua is a leading HVAC&R manufacturer of controls and components with a global footprint and 30 years of experience.

More information

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax: TECHNICAL MANUAL CX(E) SPLIT SYSTEMS CONTENTS INDEX PART NUMBERS, OPTIONS, UNIT COMBINATIONS, DIMENSIONS & WEIGHTS 3 PERFORMANCE DATA & AIR FLOW 4 SOUND POWER AND SOUND PRESSURE LEVELS 5 ELECTRICAL DATA

More information

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system Core 1. Ozone in the stratosphere above the earth consists of: a. Molecules containing 3 oxygen atoms. b. Molecules of 2 oxygen atoms. c. Radioactive particles. d. Pollutants that have risen from ground

More information

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options DuPont Refrigerants R22 market and the ISCEON retrofit options Airefrig November 2010 John McCormack Business Manager DuPont Chemicals and Fluoroproducts HCFC Regulations & ISCEON 3 Actions Impacting Fluorochemicals

More information

Cooling System Equipment

Cooling System Equipment Air Conditioning Service Centers Leak Detectors Recyclers 2007 Buyers Guide 223 Brake & Refrigerant Handling REFRIGERANT RECOVERY/RECYCLING SYSTEMS Cool-Tech R-134A Recovery, Recycling And Recharging System

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

Air Conditioning & Duracool Emery Stora

Air Conditioning & Duracool Emery Stora Air Conditioning & Duracool Emery Stora X Low refrigerant Clutch cut off switch * *Leaves compressor as High pressure gas **Leaves condenser as High pressure liquid ** Changes from a high Pressure liquid

More information

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) INDEX UNIVERSAL ELECTRONIC CONTACTOR UPGRADE SURESWITCH 79 Description Model(s) Page(s) SureSwitch... 49P11-843... 79 CONTACTORS 80 82 Description Model(s) Page(s) 1 Pole... 94-388 Thru 94-395... 80 2

More information

TRS21 IGNITION PROOF SERIES

TRS21 IGNITION PROOF SERIES TRS21 IGNITION PROOF SERIES 2 Cylinder Commercial Recovery Machine OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS21A, TRS21E TO BE OPERATED BY QUALIFIED

More information

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION CONDITIONERS DRY CHARGE UNITS PRODUCT SPECIFICATIONS Bulletin No. 20636 May 204 Supersedes March 202.5 to 5 Tons MODEL NUMBER IDENTIFICATION L C S 3 DC - 036-230 - 2 Lennox Minor Revision Number Air Conditioner

More information

The Essentials Of Working With R-410A

The Essentials Of Working With R-410A The Essentials Of Working With R-410A By Norm Christopherson Several major manufacturers are producing comfort air conditioning equipment using refrigerant 410A. The trend towards the use of 410A continues

More information

Devair and Miscellaneous Table of Contents

Devair and Miscellaneous Table of Contents Devair and Miscellaneous Table of Contents Get The Compressed Air Quality Your Application Requires... 2 Air Compressors 5 HP and 7 1/2 HP Models... 3 10 HP and 15 HP Models... 3 25 HP and 30 HP Models

More information

Refrigerant Recovery/Recharging Series

Refrigerant Recovery/Recharging Series TrustworthyBrandChinaChunMu Refrigerants TrustworthyBrandChinaChunMu 2012 Refrigerant /Recharging Series Portable Refrigerant /Recharging Unit Light Commercial HVAC Industrial Refrigeration System Automotive

More information

REFRIGERANT REFERENCE GUIDE

REFRIGERANT REFERENCE GUIDE United States National Refrigerats, Inc. 1140 Roosevelt Boulevard Philadelphia, PA 19154 215-698-6620 800-262-0012 Fax: 215-698-7466 United Kingdom National Refrigerants of America Ltd. 4 Watling Close

More information

PULSE WIDTH MODULATING VALVES

PULSE WIDTH MODULATING VALVES PULSE WIDTH MODULATING VALVES PARKER PULSE WIDTH MODULATING VALVES MODEL HP P4144 MODELS CS & DS P4145 Features Long life (100 million cycles). Suitable for all common refrigerants except ammonia. Maximum

More information

208 For more information visit our website at

208 For more information visit our website at REFRIGERANTS REFRIGERANT Realcold supply refrigerants sourced from A-Gas for all applications. All refrigerant products are quality assured under AHRI 700 International Refrigerant Standards. We offer

More information

GRF Series Non-Cycling Refrigeration Dryers ANDARD ELECTRONIC DRAIN STANDARD ELEC SS EXPANSION VALVE F PRESSURE DEWPOINT

GRF Series Non-Cycling Refrigeration Dryers ANDARD ELECTRONIC DRAIN STANDARD ELEC SS EXPANSION VALVE F PRESSURE DEWPOINT ANDARD ELECTRONIC DRAIN 5 -YEAR WARRANTY STANDARD ELECTRONICC 5 -YEAR WARRANTY 35-39 F PRESSURE DEWPOIN SS EXPANSION VALVE STANDARD ELECTRONIC DRAIN 35-39 F PRESSURE DEWPOINT SS EXPANSION VALVE STANDARD

More information

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e. ORTEC Compressed Air, Gas & Fluid Technologies t a l r o n m e n i l y E n v F r i e n d t r a n l y R e i g e f r INDUSTRIAL FLUID CHILLERS FC SERIES (0-00 TONS) Application Flexibility Nortec Industrial

More information

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11 SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual No.: 2100-479 Supersedes: NEW File: Volume

More information

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved. GUIDELINES FOR THE UTILIZATION OF R-404A R-452A Page 1 of 10 GUIDELINES FOR THE UTILIZATION OF R-404A AND R-452A For many years, R-404A has emerged as the industry's major choice as an alternative refrigerant

More information

DESIGN STANDARDS SECTION 15600

DESIGN STANDARDS SECTION 15600 PART 1 - GENERAL 1.1 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.2 General requirements: A. Reciprocating

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 2008 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS Merit Series 13ACX Units RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING Improper installation, adjustment, alteration, service

More information

2002 Dodge Caravan SE

2002 Dodge Caravan SE EVAPORATOR (FRONT) Removal 1. Remove the HVAC housing from the vehicle. See HVAC HOUSING (FRONT). Remove the heater hoses from the heater core. 2. Remove and discard the foam seal from the HVAC housing

More information

1. Can SUPER SEAL ACR, SUPER SEAL HVACR & SUPER SEAL COMMERCIAL be used interchangeably? No, use as per application guidelines below:

1. Can SUPER SEAL ACR, SUPER SEAL HVACR & SUPER SEAL COMMERCIAL be used interchangeably? No, use as per application guidelines below: SUPER SEAL HISTORY Work on Super Seal leak sealants for residential and commercial systems began in August 1999, after the successful introduction of Cliplight's Super Seal Pro, for automotive systems.

More information

OWNER S MANUAL (English)

OWNER S MANUAL (English) TR600 Series Refrigerant Recovery Machines OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TR600, TR610, TR600C, TR610C, TR600S, TR600K, TR600E TO BE

More information

A/C Refrigerant. Air Conditioning systems use refrigerant to move heat from air inside the car to air outside the car

A/C Refrigerant. Air Conditioning systems use refrigerant to move heat from air inside the car to air outside the car A/C Refrigerant Air Conditioning systems use refrigerant to move heat from air inside the car to air outside the car Refrigerants are HAZARDOUS to you and the environment Motor Vehicle Air Conditioning

More information

Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C

Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C McQuay International (A Member of the DAIKIN Group) Hydrofluorocarbon (HFC) refrigerants are critical to the safe and cost-effective phase-out

More information

Application Guide. Retrofit Guidelines

Application Guide. Retrofit Guidelines Application Guide Retrofit Guidelines APP-APG011-EN Replacing systems that use HCFC-22 Reusing existing refrigerant lines Converting HCFC-22 systems to HFC410A Converting HFC410A indoor units to HCFC-22

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Series Units RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING Improper installation, adjustment, alteration, service or maintenance can cause personal injury, loss of life,

More information

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS AIR CONDITIONERS 13ACXN MERIT Series R-410A Bulletin No. 210831 January 2018 Supersedes Bulletin No. 210739 SEER up to 15.50 1.5 to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh

More information

A/C SYSTEM GENERAL SERVICING

A/C SYSTEM GENERAL SERVICING A/C SYSTEM GENERAL SERVICING 1988 Jeep Cherokee 1988 AIR CONDITIONING & HEAT A/C General Servicing Diagnostic Procedures Eagle & Jeep * PLEASE READ THIS FIRST * CAUTION: When discharging air conditioning

More information

Gary Parker Refrigerants Product Manager

Gary Parker Refrigerants Product Manager Gary Parker Refrigerants Product Manager Refrigerant f i t History Status of the HCFC ( R22) Phase out Ozone Friendly Alternativesti Choosing the Best Retrofit Solution Lubricants and how they impact performance

More information

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2) CS*/CD*/CP* Series Air Cooled Condensing Units Operating and Installation Manual CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2) TABLE OF CONTENTS I. Receipt of Equipment 2 II. Piping...4 III. System

More information

Installation Manual for CCS Cased Coils with SC, SD, SW Compressor Units and R-410A Refrigerant

Installation Manual for CCS Cased Coils with SC, SD, SW Compressor Units and R-410A Refrigerant EarthLinked TXV Kit Installation Manual for CCS Cased Coils with SC, SD, SW Compressor Units and R-410A Refrigerant CONTENTS PAGE Pre-Installation 3 Cased Coil Conversion 4 System Start-Up 17 TXV CCS-410-KIT

More information

Gary Parker Refrigerants Product Manager

Gary Parker Refrigerants Product Manager Gary Parker Refrigerants Product Manager Refrigerant History Status of the HCFC ( R22) Phase out Ozone Friendly Alternatives Choosing the Best Retrofit Solution Lubricants and how they impact performance

More information

SECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.

SECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories. SECTION 15650 REFRIGERATION EQUIPMENT PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories. B. Related Section: 1. 11400

More information

Research Design Quality Value Service Experience

Research Design Quality Value Service Experience 2017 INDEX ACCUMULATORS...27 ACCUMULATOR - DRIERS...27 CAPILLARY ASSEMBLIES Strainer...30 Strainer-Drier...29 CONDENSERS (WATER COOLED) Coaxial...19 Shell & Coil...18 DRIERS Big R...28 Junior...29 Filter...25

More information

SpeedClean. Work Smarter NEW! Innovative cleaning products for maximum HVAC system efficiency. Innovative Maintenance Tools.

SpeedClean. Work Smarter NEW! Innovative cleaning products for maximum HVAC system efficiency.  Innovative Maintenance Tools. Work Smarter SpeedClean Innovative Maintenance Tools. Innovative cleaning products for maximum HVAC system efficiency. NEW! CoilShot Condenser Cleaning System www.speedclean.com Contents Coil Cleaning

More information

OPERATION & MAINTENANCE MANUAL AC860

OPERATION & MAINTENANCE MANUAL AC860 OPERATION & MAINTENANCE MANUAL AC860 Refrigerant Handling System Manual P/N 035-80913-00 TABLE OF CONTENTS Startup & Safe Operation... 1 Introduction to the AC860... 2 Control Panel... 3 Keypad Functions...

More information

HVAC Service Technicians Training Center

HVAC Service Technicians Training Center HVAC Service Technicians Training Center 48-03 32 nd Place, Long Island City, NY 11101 Tel: (718) 472-0404 (718) 472-0414 Fax: (718) 433-0676 Introduction to the Refrigeration Cycle: Part 1 (AC/R-1) This

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ,t_2007 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CH33 Series Units EVAPORATOR 505,264M (65484504) 10/07 Supersedes 09/06 COILS n _putech blications ical Litho U.S.A. RETAIN THESE

More information

REFRIGERANT RECOVERY DEVICES AND ACCESSORIES

REFRIGERANT RECOVERY DEVICES AND ACCESSORIES DEVICES AND ACCESSORIES DEVICES AND ACCESSORIES PROMAX RECOVERY DEVICES PROMAX designs, engineers, and manufacturers the highest quality service equipment and makes it easy to use for all refrigerant handling

More information

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system Core 1. Ozone in the stratosphere above the earth consists of: a. Molecules containing 3 oxygen atoms. b. Molecules of 2 oxygen atoms. c. Radioactive particles. d. Pollutants that have risen from ground

More information

Aspects of the. Following these key guidelines during a compressor changeout can ensure a successful, more efficient replacement.

Aspects of the. Following these key guidelines during a compressor changeout can ensure a successful, more efficient replacement. Aspects of the Compressor Retrofit Following these key guidelines during a compressor changeout can ensure a successful, more efficient replacement. B y J o h n P r a l l a n d D e n n y M a r t i n All

More information

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES SECTION 23 23 00 REFRIGERANT PIPING AND SPECIALITIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Refrigerant piping. 2. Unions, flanges, and couplings. 3. Pipe hangers and supports. 4. Refrigerant

More information

DEHYDRATORS AND FILTERS

DEHYDRATORS AND FILTERS DEHYDRATORS AND FILTERS 91 DEHYDRATION OF REFRIGERANTS Among contaminating agents causing serious damages to refrigerating systems, moisture plays a major role. Its presence, even possible in the refrigerating

More information

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006 Submittal Prepared For: All Bidders Sold To: Date: January 8, 209 Customer P.O. Customer Project Job Job Name: City of Carrollton Fire Splits 623 Beltline Road CARROLLTON, TX 75006 Trane U.S. Inc. dba

More information

OPER LV Wheeler Way

OPER LV Wheeler Way OPER RATING INSTRUCTIONS LV5 REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 Wheeler Way Langhorne, PA 19047 Ph:(215) 638-8909 9 info@ @nrproducts.com LV5.DOC 9.17.2018 MODEL LV5 REFRIGERANT

More information

Installation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant

Installation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant EarthLinked TXV Kit Installation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant CONTENTS PAGE Pre-Installation 3 Air Handler Conversion 4 System

More information

Product Data. Features/Benefits. 19XB Positive Pressure Storage System

Product Data. Features/Benefits. 19XB Positive Pressure Storage System Product Data 19XB Positive Pressure Storage System 19XB028 Copyright 1992 Carrier Corporation 19XB052 Carrier s Positive Pressure Storage (PPS) System ensures the critical conservation of refrigerants

More information