Indirect Gas-Fired Make-Up Air

Size: px
Start display at page:

Download "Indirect Gas-Fired Make-Up Air"

Transcription

1 Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041

2 Product Features Model IG Indirect Gas-Fired Make-Up Air Unit The Greenheck model IG features a power vented, 80% efficient, ETL Listed, indirect gas-fired furnace. Heating is available up to 400,000 Btu/hr (input) with airflow volumes up to 7,000 cfm. Units are factory assembled and wired to minimize field installation time and costs. Indirect Gas-Fired Furnaces Power vented with post purge cycle ETL Listed to ANSI standard Z83.8 and CGA % thermal efficiency Gas control options include up to 8:1 staged turndown and up to 4:1 modulating turndown Aluminized steel or stainless steel heat exchanger Direct spark ignition system Easy access burner controls Insulated double wall construction Control Center The control center includes the following standard components: Magnetic motor starter with solid state overload protection Control transformer with fusing Disconnect switch Separately fused motor Distribution terminal strip Premium grade control components are selected to provide you with years of reliable operation. All electrical components are UL Listed, recognized or classified and factory prewired for single point power connection. Vibration Isolators The entire fan and motor assembly is mounted on Neoprene vibration isolators to minimize noise transmission into the building. Filters Filter options include 2-inch pleated 30% efficient filters or 2-inch washable aluminum mesh filters. 2 Integrated Downturn Plenum Greenheck s unique indirect furnace design includes an integrated downturned plenum, eliminating the need for an additional section to achieve a downblast discharge. Durable Construction Designed for maximum weather resistance, IG housings are constructed of heavy gauge G90 galvanized steel. Insulated double wall construction and lifting lugs are standard. Reliable Fan Performance Air performance ratings from Greenheck s AMCA registered test chamber ensure accurate data. Double width, double inlet forward curved wheels for high efficiency and low sound levels are constructed of heavy gauge steel. Wheels are statically and dynamically balanced to ensure vibration free operation. Access Panels Large access panels are provided for easy inspection and maintenance of motors, drives, fan wheels, filters, and heater controls. Factory Wired and Tested All units are tested prior to shipment to ensure Greenheck s high level of quality. Units are checked for proper fan, furnace and controls operation.

3 installation Options Downblast or Horizontal Discharge Model IG is available in either downblast (Arrangement DB) or horizontal (Arrangement HZ) discharge. Arrangement DB utilizes Greenheck s integrated downturned plenum to provide you with the most compact downturn design available. Kitchen Combination Package The Greenheck combination package (Arrangement DBC) simplifies installation and reduces your field labor costs. This pre-engineered design offers you the benefit of only one roof penetration for both supply and exhaust ducts, while ensuring complete compatibility and interface between the supply fan, exhaust fan, curb and combination extension. Greenheck combination packages are specifically designed to comply with NFPA 96, which states: Exhaust duct must terminate at least 24 in. above the roof deck. Exhaust fan discharge must terminate at least 40 in. above the roof deck. There must be at least 10 ft. of horizontal separation between the intake and exhaust discharge. Venting Options When your application calls for indoor installation, Greenheck offers multiple venting options: Basic Indoor Venting Separate 2-Pipe Venting Concentric Venting Through Wall Through Wall Through Wall Through Roof Basic indoor venting uses indoor air for combustion and vents combustion by-products outdoors through a vent line in the wall or roof. Through Roof Separate 2-pipe venting uses outdoor combustion air and vents combustion by-products outdoors through a vent line, requiring separate roof or wall openings for each line. Through Roof Concentric venting uses outdoor air for combustion and vents combustion byproducts outdoors through a vent line, but offers you the benefit of only one roof or wall penetration. 3

4 OPTions Evaporative Cooling Mixing Box The capabilities of the IG can be expanded to include cooling with the addition of an evaporative cooling section. The evaporative cooling section includes a galvanized steel housing with a louvered intake, 2 inch aluminum mesh filters and a stainless steel evaporative cooling module. The evaporative cooling media is 12 inch thick Munters CELdek or GLASdek for a 90% cooling effectiveness. The entire section mounts directly to the front of the IG unit, eliminating transitions and ductwork by others. Drain and overflow are conveniently tapped through the side of the cooling section. The supply line connection is field located where convenient. Freeze protection, automatic drain & fill and the Water Wizardª evaporative optimizer are available. Evaporative cooling is available up to 7,000 cfm. You may further expand the make-up air capabilities of the IG with the addition of a mixing box. This option includes low leakage control dampers for outdoor and return air, and an actuator in a face and bypass configuration. IG units with a mixing box include a louvered intake to prevent moisture from entering the mixing box section. The Greenheck mixing box allows you to choose from three standard airflow control options: Two Position: Responding to user input, the return air damper is either fully open (recirculating 100% return air) or fully closed (providing 100% outdoor air). Building Pressure Control: Outdoor air and return air dampers modulate to maintain desired building pressure. Furnace control is based on discharge temperature. A remote control panel with photohelic gauge is required with this option. Potentiometer Control: Enables manual control of the outdoor air and return air damper positions. Furnace control is based on discharge temperature. A remote control panel is required with this option. Furnace Control Choose from staged or modulating furnace control. Staged Control 1-Stage, 2-Stage or 8-Stage Control Modulating Control 2:1 or 4:1 Modulation Control Control Operation Points* Control Operation Points* 1-Stage 100% 2:1 Modulation Anywhere from 50 to 100% 2-Stage 50, 100% 4:1 Modulation Anywhere from 25 to 100% 8-Stage 121/2, 25, 371/2, 50, 621/2, 75, 871/2, 100% *Percentage of maximum furnace output. *Percentage of maximum furnace output. Temperature Control Discharge Temperature Control As a make-up air unit, the IG controls the heat output based on the discharge temperature. A factory mounted discharge temperature sensor feeds information back to the unit control center. The furnace either stages or modulates the heat output to satisfy the discharge temperature set point. The set point is easily field adjusted with a temperature selector located in the unit s control center. Room Override The room override option enables the IG to boost its heat output when the space temperature is cooler than desired. When the space temperature is satisfied, the IG will control the heat output based on the discharge temperature set point. The room sensor may be wall or beam mounted or included on an optional remote control panel. 4

5 accessories Remote Control Panels The Industrial type remote control panel features a variety of switches and indicator lights mounted on a Permatector coated galvaneal steel box. If room override is specified, the override thermostat is factory mounted on the remote panel as shown to the right. Kitchen style remote panels features toggle switches and a stainless steel face plate for flush mounting to a wall. The junction box is also included. Additional Accessories Air Filter Gauge Indicates when filters become dirty. An indicator light may be wall, beam or remote control panel mounted. Motorized Dampers Intake or discharge dampers are available to prevent backdrafts when the fan is not in operation. Intake dampers are factory mounted and wired. Inlet Air Sensor An on/off type duct stat automatically de-energizes the gas system, interrupting the flow of gas to the burners when the inlet air temperature rises above the inlet air sensor set point. 115 Volt Service Receptacle A 115 volt GFCI outlet is mounted externally in a NEMA-3R box for the convenience of field service personnel. A separate 115 volt power source is required. Roof Curbs Factory provided roof curbs are available to ensure compatibility between the make-up air unit and roof curb. Standard construction is G90 galvanized steel. Freezestat An on/off type discharge duct stat, with timer, prevents the discharge of cold air into the building when the furnace is not providing adequate tempering. Special Coatings Greenheck s Permatector powder paint is available for cosmetic or protective purposes. Decorative baked enamel paints are also available in a variety of colors to match existing building fixtures. Consult your Greenheck representative for paint selections. Weatherhood A galvanized steel weatherhood with birdscreen is standard on 100% outdoor air units. A louvered intake is optional. Propane Gas A propane heater may be provided in lieu of natural gas. Duct Adapter A duct adapter is available with factory supplied curbs and provides an easy method for connecting the ductwork to the curb. Exhaust Fan Starter(s) Up to 2 exhaust fan starters may be added to the control center. Smoke Detector A photoelectric smoke detector is available for duct mounting. Discharge Diffuser A 3-way diffuser for horizontal discharge or 4-way diffuser for downblast discharge are available. 5

6 PERFORMANCE DATA Furnace, and Blower Availability MBH Air Performance Data CFM ,200 RPM BHP RPM BHP CFM 1,500 2,400 CFM 2,000 3,000 CFM 2,600 4,400 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP CFM 4,000 7,000 RPM BHP RPM BHP Note: The air performance data shown does not include internal static pressure losses due to items such as filters, dampers and furnaces. For exact air performance data based on specific unit configuration, use the Greenheck CAPS selection program.

7 Dimensional data Arrangement HZ and DB B A 36 in Without Evaporative Cooling B Intake A B A Width 100% Standard /4 Outside Air Louvered 111/2 Recirculation Standard Louvered 111/2 431/2 100% Standard /4 Outside Air Louvered 111/2 Recirculation Standard Louvered 111/2 521/2 100% Standard /4 Outside Air Louvered 111/2 Recirculation Standard Louvered 111/2 521/ With Evaporative Cooling Evap* A B Width 100% 3500 cfm 521/2 731/4 Outside Air 36 Recirculation 3500 cfm 521/ in. 100% 3500 cfm 521/2 761/4 Outside Air 36 Recirculation 3500 cfm 521/ % 3500 cfm 521/2 851/4 Outside Air 36 Recirculation 3500 cfm 521/2 102 Arrangement DBC 10 ft. minimum A** 56 in.** Without Evaporative Cooling With Evaporative Cooling Intake A Width Standard 182 Louvered 1671/2 48 Standard 183 Louvered 1681/2 521/2 Standard 181 Louvered / Evap* A Width 3500 cfm 521/2 1691/ cfm 521/ cfm 521/2 191 * Maximum evaporative cooler air volume (cfm). ** Arrangement DBC dimensions are based on the largest compatible CUBE fan. For specific dimensions, use the Greenheck CAPS selection program. All dimensions are in inches. 7

8 Typical Specifications General: Make-up air unit shall be as manufactured by Greenheck Fan Corporation or approved equal provided all specifications are met. Greenheck Model IG is used as the basis of design. Performance shall be as scheduled on plans. Furnace: Indirect fired gas furnace shall be 80% efficient, ETL Listed and have a blow through fan design. Furnace shall be capable of operation with natural or LP gas and have a power venting system. The heat exchanger shall be constructed of aluminized steel or stainless steel. Standard furnace features shall include main gas pressure regulator, main gas valve, electronic staged or electronic modulating controls, direct spark ignition system, high limit and a 24 volt control transformer. Temperature Control: Furnace heat output shall be controlled based on a field adjustable discharge temperature set point. Discharge temperature sensor shall be factory mounted and wired to the unit control center. Furnace shall have electronic modulation or electronic staged control. Unit Casing and Frames: Unit shall be of internal frame type construction of galvanized steel. All frames and panels shall be G90 galvanized steel. Where top panels are joined there shall be a standing seam to insure positive weather protection. All metalto-metal surfaces exposed to the weather shall be sealed. All components shall be easily accessible through removable doors. Insulation: Units equipped with a mixing box shall be insulated from the mixing box intake through to the supply discharge. 100% outside air units shall be insulated from the filter section intake through to the supply discharge. Insulation shall be in accordance with NFPA 90A and tested to meet UL 181 erosion requirements. Double wall construction is standard. Fan Section: Centrifugal fans shall be double width, double inlet. Fan and motor shall be mounted on a common base and shall be internally isolated. All blower wheels shall be statically and dynamically balanced. Ground and polished steel fan shafts shall be mounted in permanently lubricated ball bearings. Bearings shall be selected for a minimum L 10 life in excess of 100,000 hours at maximum cataloged speeds. Filter Section: Filters shall be mounted in a V-bank arrangement such that velocities across the filters do not exceed 550 feet per minute. Filters shall be easily accessible through a removable access panel. Weatherhood: Weatherhood shall be constructed of G90 galvanized steel with birdscreen mounted at the intake. Motors and Drives: Motors shall be energy efficient, complying with EPACT standards, for single speed ODP and TE enclosures. Motors shall be permanently lubricated, heavy duty type, matched to the fan load and furnished at the specified voltage, phase and enclosure. Drives shall be sized for a minimum of 150% of driven horsepower. Pulleys shall be cast and have machined surfaces, 10 horsepower and less shall be supplied with an adjustable drive pulley. Electrical: All internal electrical components shall be prewired for single point power connection. All electrical components shall be UL listed, recognized or classified where applicable and wired in compliance with the National Electrical Code. Control center shall include motor starter, control circuit fusing, control transformer for 24 VAC circuit, integral disconnect switch and terminal strip. Contactors, Class 20 adjustable overload protection and single phase protection shall be standard. Mixing Box (2-Position): Damper shall be either fully open or fully closed. Damper position shall be controlled by a remotely mounted switch. Mixing box shall provide 100% make-up air when the damper is closed and recirculate 100% return air when the damper is open. Mixing Box (Building Pressure): Mixing box shall modulate outdoor and return air volumes to maintain desired building pressure. A remote control panel shall be provided by the make-up air unit manufacturer and include a photohelic gauge. Furnace shall be multi-stage or modulating and operate based on discharge temperature control. Mixing Box (Potentiometer): Mixing box shall enable manual modulation of outdoor and return air volumes from a remote potentiometer. The potentiometer shall be mounted on a control panel provided by the make-up air manufacturer. Furnace shall be multi-stage or modulating and operate based on discharge temperature control. Evaporative Cooling Section: Evaporative cooling section shall include a galvanized steel housing with louvered intake, 2-inch aluminum mesh filters and a stainless steel evaporative cooling module all provided by the make-up air unit manufacturer. Evaporative cooling media shall be Munters CELdek or GLASdek with a depth of 12 inches for a cooling effectiveness of 90%. Drain and overflow connections shall be piped through the side of the evaporative cooling section. Our Warranty Greenheck warrants this equipment to be free from defects in material and workmanship for a period of one year from the shipment date. Any units or parts which prove defective during the warranty period will be replaced at our option when returned to our factory, transportation prepaid. Motors are warranted by the motor manufacturer for a period of one year. Should motors furnished by Greenheck prove defective during this period, they should be returned to the nearest authorized motor service station. Greenheck will not be responsible for any removal or installation costs. Greenheck P.O. Box 410 Schofield, WI Phone (715) greenheck.com Copyright 2004 Greenheck IG RG Rev. 1 May 2004

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

Direct Gas-Fired Make-Up Air

Direct Gas-Fired Make-Up Air Direct Gas-Fired Make-Up Air Model TSU Heavy Duty, High Airflow Applications Manufacturing and Industrial Facilities Up to 64,000 cfm August 2012 Products Model TSU Direct Gas-Fired Make-Up Air Unit The

More information

Modular Heating & Ventilating Unit Model IGX-HV

Modular Heating & Ventilating Unit Model IGX-HV Modular Heating & Ventilating Unit Model IGX-HV Indirect Gas-Fired Heating Evaporative Chilled Water DX Cooling October 2008 Product Features Model IGX-HV Indirect Gas-Fired Heating and Ventilating Unit

More information

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation Industrial Space Heating Direct Gas-Fired Heating Greenheat 00% Outdoor Air Greenheat 50/50 Recirculation 80/0 Recirculation March 008 Product Overview Industrial Space Heating Greenheck s space heating

More information

Make-Up Air March 2012

Make-Up Air March 2012 Make-Up Air March 2012 Comfortable energy efficient kitchen ventilation starts here. At Larkin Industries, our goal is to manufacture well-designed kitchen ventilation systems with environmentally sustainable

More information

Direct Gas-Fired Make-Up Air Models DG and DGX

Direct Gas-Fired Make-Up Air Models DG and DGX Direct Gas-Fired Make-Up Air Models DG and DGX Commercial, Industrial and Kitchen Applications 800-48,000 cfm 4 in. wg External Static Pressure Direct Gas-Fired Heating Optional Cooling - Packaged DX (2.5

More information

Direct Gas-Fired Make-Up Air Models DGK, DG and DGX

Direct Gas-Fired Make-Up Air Models DGK, DG and DGX Direct Gas-Fired Make-Up Air Models DGK, DG and DGX Kitchen and Industrial Applications 800-48,000 cfm 4 in. wg External Static Pressure Direct Gas-Fired Heating Packaged DX (3 to 16 tons), Split DX Cooling,

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information

Make-Up Air Systems. Performance. Model DGK, DG, DGX

Make-Up Air Systems. Performance. Model DGK, DG, DGX DGK, DG, DGX 96 Make-Up ir Systems Direct Fired Gas Heat DGK-15-25 DG-10-20 -30 DGX-12-22 -32 *DGX with PDX-12-22 -32 est vailable Program 5 Days 10 Days 15 Days * est vailable based on size and capacity

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

FEATURES AND BENEFITS

FEATURES AND BENEFITS FEATURES AND BENEFITS Product Features and Benefits Full Product Line Offering Feature All models are 80% thermally efficient Blower performance up to 3.0 W.C. DX or chilled water section with factory

More information

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating Rooftop Ventilator with Packaged Cooling & Heating Models RV and RVE Institutional Commercial Industrial 800-1,500 cfm.0 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating Packaged

More information

Gas-Fired Indoor and Outdoor Duct Furnaces

Gas-Fired Indoor and Outdoor Duct Furnaces July, 2008 Gas-Fired Indoor and Outdoor Duct Furnaces INDOOR GRAVITY VENTED DFG, DBG, DCG INDOOR SEPARATED COMBUSTION DFS, DBS, DCS OUTDOOR GRAVITY AND POWER EXHAUSTED H Series table of contents A complete

More information

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

A. General: Refer to paragraph entitled SUBMITTAL in Section Include the following data: SECTION 15860 - FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR MECHANICAL

More information

Energy Recovery with Cooling and Heating Model ERCH

Energy Recovery with Cooling and Heating Model ERCH Energy Recovery with Cooling and Heating Model ERCH 100% Outdoor Air System Dedicated Outdoor Air System 1,000-10,000 cfm 1.75 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating,

More information

KIC Air Curtains. Technical Guide

KIC Air Curtains. Technical Guide TGKIC-3 KIC Air Curtains Technical Guide AIR PERFORMANCE AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. King certifies that the air curtains shown herein are licensed to bear the AMCA seal. The

More information

Energy Recovery with Cooling and Heating

Energy Recovery with Cooling and Heating Energy Recovery with Cooling and Heating VersiVent - Model VER Commercial Institutional 2,000-10,000 cfm 3.0 in. wg external static pressure Configurable September 2008 Page The VersiVent Header Model

More information

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You. TGIF- Indirect Fired Heating Systems Technical Guide for: IF Indoor Installations IFW Outdoor Installations Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide In the business of

More information

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS SECTION 237339 - DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional 1,000-6,000 cfm 2.0 in. wg External Static Pressure Aluminum Plate Heat Exchanger April 2017 Heat Recovery Ventilators Greenheck

More information

Section (CSI ) I-Series Drum & Tube (04/23/10) Indirect-Fired Heating & Ventilating

Section (CSI ) I-Series Drum & Tube (04/23/10) Indirect-Fired Heating & Ventilating Section 15700 (CSI 23 74 33) I-Series Drum & Tube (04/23/10) Indirect-Fired Heating & Ventilating Note: Optional items and/or items requiring a choice, will be shown between brackets and/or parentheses

More information

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004) High Plume Blowers Suggested Specification Section 15500 (Master Format 1996) Suggested Specification Section 23 38 16 (Master Format 2004) PART 1 GENERAL 1.01 WORK INCLUDED High Plume Laboratory Exhaust

More information

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260)

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260) Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN 46706 (260) 925-6550 Fax: (260) 925-6093 Industrial Facility Midwest Re: Facility Ventilation Audit Schust Engineering, Inc. is pleased

More information

KEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters. Table of Contents FOR YOUR SAFETY.

KEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters. Table of Contents FOR YOUR SAFETY. KEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters Table of Contents FOR YOUR SAFETY Page # Topic If you smell gas: 1 Description of Operation 1 Receiving the

More information

May, 2004 Commercial & Industrial Applied Product Line Heating Ventilating Cooling Make-Up Air

May, 2004 Commercial & Industrial Applied Product Line Heating Ventilating Cooling Make-Up Air 75-137.5 May, 2004 Commercial & Industrial Applied Product Line Heating Ventilating Cooling Make-Up Air MODINE COMMERCIAL & INDUSTRIAL APPLIED PRODUCT LINE Modine has always been the industry standard

More information

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15732 - PACKAGED ROOFTOP AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Package roof top unit. B. Heat exchanger. C. Refrigeration components. D. Unit operating controls. E. Roof

More information

Installation, Operation and Maintenance Manual **FOR YOUR SAFETY**

Installation, Operation and Maintenance Manual **FOR YOUR SAFETY** MODEL IGX Make-Up Air Unit Installation, Operation and Maintenance Manual Part # 462876 **FOR YOUR SAFETY** If you smell gas: 1. Open windows. 2. Don t touch electrical switches. 3. Extinguish any open

More information

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters. SECTION 15622 DIRECT GAS-FIRED BURNER & MANIFOLD SYSTEM PART 1: GENERAL 1.1 Section includes: A. Direct gas-fired heater modules B. Controls C. Equipment schedule 1.2 Related Sections A. Section 01655:

More information

INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG

INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG COMMERCIAL/INDUSTRIAL AIR HANDLER AND CONDENSING UNIT AIR HANDLER CAPACITIES 563-7,593 CFM Air 20-400 MBH Heating (Gas/LP) 10-120 kw Heating (Electric) 5-20 Tons

More information

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters. Section 15 _ Energy Recovery Air Handling System Part 1: GENERAL 1.1 Section Includes: A. Energy Recovery Air Handler B. Controls (most by Others) C. Equipment Schedule 1.2 Related Sections: A. Section

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 233423 - HVAC POWER VENTILATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 PERFORMANCE REQUIREMENTS A. Operating

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

Equipment Specifications

Equipment Specifications Equipment Specifications GAS/OIL HEATING ONLY INDIRECT-FIRED AIR HANDLER GUIDE SPECIFICATION PART 1 GENERAL [Gas][Oil][Gas/Oil Combo]-Fired Please note: Brackets indicate required choices to be made in

More information

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Construction Standards Page 233423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified

More information

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, 300 15, 18, 20, and 25 NOMINAL TONS COMMERCIAL ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS ELECTRIC HEATING/ELECTRIC COOLING UNITS

More information

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT SECTION 23 81 00 DECENTRALIZED UNITARY HVAC EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes packaged roof top unit, unit controls, remote panel, roof mounting curb and base, maintenance service,

More information

Gas-Fired Indoor and Outdoor Duct Furnaces

Gas-Fired Indoor and Outdoor Duct Furnaces October, 2010 Gas-Fired Indoor and Outdoor Duct Furnaces INDOOR GRAVITY AND POWER VENTED DFG/DFP, DBG/DBP, DCG/DCP INDOOR SEPARATED COMBUSTION DFS, DBS, DCS OUTDOOR GRAVITY AND POWER EXHAUSTED H Series

More information

SECTION (15833) - HVAC POWER VENTILATORS

SECTION (15833) - HVAC POWER VENTILATORS PART 1 GENERAL 1.01 SUMMARY SECTION 23 34 23 (15833) - HVAC POWER VENTILATORS A. Section Includes: 1. Centrifugal Roof Ventilators. 2. Up-blast Roof Exhaust Fans (Kitchen Hood Exhaust). 3. Ceiling-Mounted

More information

GreenJet Transfer Fans

GreenJet Transfer Fans GreenJet Transfer Fans Model GJX High Performance Axial Transfer Fan April 2018 GreenJet As cars park in an underground parking structure, carbon monoxide (CO) and other noxious fumes are emitted into

More information

Tunnel Transit Dampers. Heavy Duty Tunnel Transit Life Safety

Tunnel Transit Dampers. Heavy Duty Tunnel Transit Life Safety Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety November 2011 Heavy Duty/Industrial Tunnel Dampers Applications Dampers in subway tunnels and transit systems serve three primary functions,

More information

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT SECTION 15300 - HVAC - MAJOR EQUIPMENT PART 1 - GENERAL 1.1 MECHANICAL GENERAL A. Section 15010 is applicable. PART 2 - PRODUCTS 2.1 FANS A. General: 1. All fans shall bear the AMCA Certified Performance

More information

Plenum Fans. Model HPA. Direct Drive

Plenum Fans. Model HPA. Direct Drive Plenum Fans Model HPA Direct Drive October 2012 Quiet & Efficient HPA Plenum Fans Greenheck s modular plenum fan, model HPA, is designed and engineered to provide superior performance and reliability in

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

Counterflo CF BASIC COUNTERFLO HEATER RCF CURB MOUNTED ROOFTOP HEATER CFDF COUNTERFLO DUCT FURNACE INDIRECT-FIRED INDUSTRIAL HEATERS

Counterflo CF BASIC COUNTERFLO HEATER RCF CURB MOUNTED ROOFTOP HEATER CFDF COUNTERFLO DUCT FURNACE INDIRECT-FIRED INDUSTRIAL HEATERS Bulletin CF-1 May 2005 Supersedes CF-1 Dated February 1998 Counterflo INDIRECT-FIRED INDUSTRIAL HEATERS Self-contained, Automatic, Indirect-fired, Warm-air Heater C.S.A. APPROVED UNITS AVAILABLE Natural

More information

TYPICAL CPA SPECIFICATIONS

TYPICAL CPA SPECIFICATIONS TYPICAL CPA SPECIFICATIONS 4/10/2017 UNIT CONSTRUCTION: Casing: The exterior casing of the unit shall be constructed of 18-gauge, G235 galvanized steel (optional stainless steel or aluminum), unpainted.

More information

HARTZELL. Tempered Air Heating Equipment. Hartzell Fan, Inc., Piqua, Ohio

HARTZELL. Tempered Air Heating Equipment. Hartzell Fan, Inc., Piqua, Ohio Tempered Air Heating Equipment Series GFR GMC GMP SAH SCH SFC SMC SMP 77 78H 78V 79 811 Hartzell Fan, Inc., Piqua, Ohio 45356 January 2011 Index Hartzell Model Code Explanation..................... Page

More information

INDIRECT GAS-FIRED AIR HEATER

INDIRECT GAS-FIRED AIR HEATER INDIRECT GAS-FIRED AIR EATER DG() SERIES INDOOR/OUTDOOR INSTALLATION MANUFACTURED BY TABLE OF CONTENTS Description... Applications... Selection criteria... Installation guidelines... Selection table...7

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

Submittal Data Performance Data Electrical Data

Submittal Data Performance Data Electrical Data ERMS Series Submittal Data Submittal Data Unit Designation: Job name: Architect: Engineer: Contractor: Performance Data Revision: 07/01/11 Cooling Capacity: EER: Heating Capacity: COP: Ambient Air Temp:

More information

Chilled Water DOAS Fan Powered Terminal Units

Chilled Water DOAS Fan Powered Terminal Units Chilled Water DOAS Fan Powered Terminal Units CHILLED WATER DOAS FAN POWERED TERMINAL UNITS DOAS TERMINAL UNITS FEATURES AND BENEFITS MINIMUM VENTILATION CONTROL The DOAS unit provides the Designer, Owner

More information

SECTION AIR HANDLING UNIT

SECTION AIR HANDLING UNIT SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR

More information

Field Start-Up Sheet Direct Fired Gas Equipment

Field Start-Up Sheet Direct Fired Gas Equipment Customer: Sales Representative: Model Number: Serial Number: Field Start-Up Sheet Direct Fired Gas Equipment ***Please Print*** INITIAL INSPECTION I. Installer Responsibilities 1. Remote Panel: All interconnecting

More information

Contents INDEX. TDM Series Indirect Fired Heaters

Contents INDEX. TDM Series Indirect Fired Heaters Contents Typical Indoor Installations................... 000 Indoor Unit Dimensions (Vertical).............. 000 Indoor Unit Dimensions (Horizontal)............ 000 Outdoor Unit Dimensions.....................

More information

Directflow SBDR/SBD SERIES

Directflow SBDR/SBD SERIES Bulletin SBDR/SBD-1 January 2015 Supersedes SBDR/SBD-1 Dated April 2014 Directflow SBDR/SBD SERIES DIRECT GAS-FIRED MAKE-UP AIR SYSTEMS Cooling Can Be Added A MODEL FOR EVERY APPLICATION SBD Direct Gas-Fired

More information

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design Fan motor (PSC or ECM). UL Listed 1 insulation conforms to UL Test 181 and NFPA 90A. Plenum air filter rack. (Filter Optional) Casing has

More information

48TF GAS HEATING/ ELECTRIC COOLING UNITS

48TF GAS HEATING/ ELECTRIC COOLING UNITS 48TF-4SB 48TF004-014 GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS 48HJ-13SB Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT

More information

Product Specifications. Vertical Floor Consoles By First Co.

Product Specifications. Vertical Floor Consoles By First Co. NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL NVC2 THRU NVC6 ULTRA LOW NOx GAS BURNERS SUB 9 PPM NOx WITH CONTROLINKS CONTROLS THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas

More information

The H Series. Pure and Simple Solutions. HTLV Space Heating

The H Series. Pure and Simple Solutions. HTLV Space Heating The H Series Pure and Simple Solutions HTLV Space Heating Proven alternative to blow-through design Design flexibility & application versatility Optimized IAQ & occupant comfort The H Series AbsolutAire

More information

HVAC HEATING PRODUCTS

HVAC HEATING PRODUCTS GTFC-7 HVAC HEATING PRODUCTS Application Manual SF/SC Series TF/TC Series GG Series TUBULAR GAS-FIRED UNIT HEATERS Contents PAGE GENERAL INFORMATION All Series 2 GG SERIES Standard/Optional Features 3

More information

STR-Series Indirect-Fired Air Turnover Units

STR-Series Indirect-Fired Air Turnover Units STR-Series Indirect-Fired Air Turnover Units Equipment Specifi cations 1.800.589.3691 www.weather-rite.com GAS/OIL HEATING ONLY INDIRECT-FIRED AIR TURNOVER UNIT GUIDE SPECIFICATIONS PART 1 GENERAL [Gas][Oil][Gas/Oil

More information

Directflow SBDR/SBD SERIES

Directflow SBDR/SBD SERIES Bulletin /SBD-1 June 2005 Supersedes SBD-1 Dated February 2005 and -1 Dated March 2001 Directflow /SBD SERIES DIRECT GAS-FIRED MAKE-UP AIR SYSTEMS Cooling Can Be Added A MODEL FOR EVERY APPLICATION SBD

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS 036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The

More information

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS SECTION 237413 - PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, outdoor, central-station air-handling units (rooftop units) with the

More information

SECTION AIR DOORS

SECTION AIR DOORS SECTION 23 34 33 AIR DOORS Berner Series VSA air doors are designed for openings up to 12 ft for environmental separation and up to 10 ft for insect control. Berner Series VSB air doors are designed for

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual MODEL DG Direct Fired Gas Make-Up Air Part #459335 Installation, Operation and Maintenance Manual Natural or LP gas ETL Listed R **IMPORTANT** ALL FACTORY PROVIDED LIFTING LUGS MUST BE USED WHEN LIFTING

More information

Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety

Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety November 2017 Heavy Duty/Industrial Tunnel Dampers Applications Dampers in subway tunnels and transit systems serve three primary functions,

More information

Understanding Fan System Effects

Understanding Fan System Effects Fan Application FA/101-99 A technical bulletin for engineers, contractors and students in the air movement and control industry. Understanding Fan System Effects The air moving industry uses a common term

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You TGIFR IFR Indirect Fired Gas Heating Systems Technical Guide for: Outdoor Rooftop Mounted Units To 46,000 CFM And 4,000 MBH Output Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide

More information

SUBMITTAL SCHEDULE & DATA

SUBMITTAL SCHEDULE & DATA SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Job Name: Date: 10/31/2016 Location: Engineer: Submitted by: Jeff Musto Architect: Contractor: Model

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004 Engineering Bulletin Gas Heat for M-Series and T-Series Climate Changer Air Handlers March 2004 CLCH-PRB010-EN Preface Gas heat can be a good heating option for any of the following applications: Climates

More information

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

CATALOG. SKYPAK Self-Contained Heating/Cooling Units CATALOG SKYPAK Self-Contained Heating/Cooling Units FORM SK145.00-EG6 (1211) TABLE OF CONTENTS SKYPAK Self-Contained Heating/Cooling Units Introduction...3 Product Overview...3 Nomenclature...4 SKYPAK

More information

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013 SECTION 15800 - AIR HANDLING EQUIPMENT 1.1 GENERAL A. All air handlers installed shall conform to the University of Rochester specification Guideline for Semi-Custom and Pre-Engineered Air Handling Units.

More information

Air Make-Up Units. Product Line Overview & Capabilities

Air Make-Up Units. Product Line Overview & Capabilities Air Make-Up Units Product Line Overview & Capabilities Air Make-Up Units Customized Solutions Unmatched Flexibility As one of the most sophisticated manufacturers of Air Make-Up Units, Aerovent s unique

More information

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System PART 1 SYSTEM DESCRIPTION 1.1 The HVAC system is based on the CGC HYBRID Hydronic Heat Pump System. 1.2 The system will automatically

More information

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU) AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory

More information

GA Gas Unit Heater Assemblies Technical Guide

GA Gas Unit Heater Assemblies Technical Guide TGGA-2 GA Gas Unit Heater Assemblies Technical Guide INDIRECT-FIRED GAS HEATING ASSEMBLIES FOR LARGE OPEN SPACES AND DOOR HEATING APPLICATIONS S ince 7, the L.J. Wing Company has been a leader in providing

More information

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL NVC ULTRA LOW NOx GAS BURNERS SUB 9 PPM NOx THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone: 620-421-0480,

More information

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY Bousquet Technologies Inc. 2121, Nobel, Ste Julie, Quebec, Canada, J3E1Z9 SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL Oil-Fired air heater for industrial and commercial use. FOR YOUR SAFETY Do not

More information

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/ 1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5

More information

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS 7 Rosemex Products 97 VENTILATION CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS 2 INTRODUCTION Rosemex "Penthouse" units are essentially outdoor mechanical rooms. They group in one compact weather proof outdoor

More information

48TM GAS HEATING/ELECTRIC COOLING UNITS

48TM GAS HEATING/ELECTRIC COOLING UNITS 48TM-4SB 48TM004-014 GAS HEATING/ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form

More information

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units TECHNICAL SPECIFICATIONS R7DA Series 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units 5.4 ISMRE Commercial System 81% Steady State Efficiency Standard Features Fits Pre-Existing Curbs High-Efficiency Low

More information

"SWVP - SWHP" COMMERCIAL WATER SOURCE HEAT PUMPS & AIR CONDITIONERS

SWVP - SWHP COMMERCIAL WATER SOURCE HEAT PUMPS & AIR CONDITIONERS "SWVP - SWHP" COMMERCIAL WATER SOURCE HEAT PUMPS & AIR CONDITIONERS Belt Driven Self-Contained Packages Vertical and Horizontal Configuration Size 6-8-10 Ton Capacities Spinnaker Industries Inc. SWHP /

More information

AHC-2. OUTDOOR AIR HANDLERS Application Manual

AHC-2. OUTDOOR AIR HANDLERS Application Manual AHC-2 OUTDOOR AIR HANDLERS Application Manual Contents 2 PAGE GENERAL INFORMATION 2 FEATURES AND BENEFITS 3 UNIT NUMBER DESCRIPTION 4 AIR HANDLER SELECTION 5 AIR HANDLER 5,6 PACKAGED ROOFTOP ARRANGEMENTS

More information

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST S Model TCBS CATALOG AX220 May 2013 TubeaxialFans Model TCBS The Twin City Fan & Blower model TCBS is a belt driven tubeaxial fan that is

More information

GQVC-12 HVAC EQUIPMENT. GAS-FIRED INDOOR HEATING EQUIPMENT A complete line of effi cient heating solutions for large, open spaces.

GQVC-12 HVAC EQUIPMENT. GAS-FIRED INDOOR HEATING EQUIPMENT A complete line of effi cient heating solutions for large, open spaces. GQVC-12 HVAC EQUIPMENT GAS-FIRED INDOOR HEATING EQUIPMENT A complete line of effi cient heating solutions for large, open spaces. 80% thermal efficiency. Heat Exchangers have a tough job to do. It's no

More information

engineering guide FH Fan-Coil Units Low-Profile, Horizontal

engineering guide FH Fan-Coil Units Low-Profile, Horizontal engineering guide FH Fan-Coil Units Low-Profile, Horizontal FORM 115.26-EG7 (908) Table of contents FH Fan-Coil Units Low-Profile, Horizontal Features and Benefits... Construction Features... Standard

More information

LARGE CAPACITY HEATERS

LARGE CAPACITY HEATERS 250 1,000 Capacities 7.5-12,850 150,000 CFM 200 MBH 250-7,500 MBH - - Tons APPLICATIONS Heating/Cooling/Makeup Air WAREHOUSES / FACTORIES SCHOOLS / UNIVERSITIES COMMERCIAL / RETAIL INDUSTRIAL GYMNASIUMS

More information

Combat. DF-Series Direct-Fired Heating, Cooling and Pressurization Systems. Equipment Specifications

Combat. DF-Series Direct-Fired Heating, Cooling and Pressurization Systems. Equipment Specifications Combat DF-Series Direct-Fired Heating, Cooling and Pressurization Systems Equipment Specifications 800.828.7450 www.rg-inc.com CANADA: 100% OUTSIDE AIR ONLY DIRECT-FIRED AIR HANDLERS GUIDE SPECIFICATION

More information

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS SECTION 23 34 16 CENTRIFUGAL HVAC FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Drawings and general provisions of the contract, including General and Special Conditions and Division 01 Specification

More information

GLOBAL FINISHING SOLUTIONS

GLOBAL FINISHING SOLUTIONS GLOBAL FINISHING SOLUTIONS > Eliminate problems with drafts, stale or contaminated air, and temperature stratification > Create balanced building pressure and maintain proper comfort levels > Introduce

More information