KPSW CONSOLE TERMINAL UNIT
|
|
- Kory Hubbard
- 6 years ago
- Views:
Transcription
1 TECHNICAL INSTRUCTIONS KPSW CONSOLE TERMINAL UNIT Cooling Heating KPSW.40 kw.75 kw KPSW.9 kw 4.07 kw KPSW 4.60 kw 5.0 kw November GB - 0
2 MARKING This product marked conforms to the essential requirements of the Directives : - Low voltage no. 006/95/EC, - Electromagnetic Compatibility no. 89/6 EEC, modified 9/ and 9/68 EEC. SUMMARY - Presentation... - Technical characteristics... - Physical characteristics Description Accessories PRESENTATION. - UTILISATION Units intended for climate control in buildings and the comfort of people. Do not place the device in rooms with high humidity or exposed to projections of water.. - FUNCTIONS Cooling or heating by means of a -pipe water coil. Ventilation with filtration (built-in filter).. - APPLICATIONS These units, derived directly from direct expansion models, are characterized by: - attractiveness, - compactness (using unused spaces), - a low sound level, - various installation possibilities (floor, wall or ceiling)..4 - MODELS "-pipe" for all sizes, with wire or infrared remote control: KPSW B 5B and KPSW B 5X.
3 - TECHNICAL CHARACTERISTICS. - NOMINAL CONDITIONS Model Total cooling capacity () HS kw MS kw LS kw Sensible cooling capacity () HS kw MS kw LS kw Heating capacity () HS kw MS kw LS kw Air flow rate HS m /h m /s MS m /h m /s LS m /h m /s Water flow rate in cooling HS l/h MS l/h LS l/h Pressure drop on water in cooling () HS kpa in the appliance MS kpa (0 kpa = m WG) LS kpa Pressure drop on water in cooling () in the flexible tubes Short length kpa (accessory) (0 kpa = m WG) Long length kpa Pressure drop on water in heating () () kpa Power supply V/f/Hz Max. power consumption kw Max. current consumption A Hydraulic connection Sound power level HS db(a) MS db(a) LS db(a) Calculed sound pressure HS db(a) (at m indoors) MS db(a) LS db(a) KPSW // KPSW // KPSW // () Air inlet: 7 C (DB) / 9 C (WB); water: inlet at 7 C, outlet at C. () Air inlet: 0 C; water inlet: 50 C (same flow-rate as under other conditions ()). () Estimated value in high speed cooling operation, with two 90 elbows on each hose.. - OTHER CONDITIONS Consult us. Operating limits: - Minimum water inlet temperature : 4 C. - Maximum water inlet temperature : 60 C. - Maximum operating pressure of the hydraulic circuit: 6 bar. - Minimum air recirculation temperature : 5 C. - Maximum air recirculation temperature : C.
4 - PHYSICAL CHARACTERISTICS Materials: - Painted metal frame. - Plastic body. - Copper/aluminium exchanger. - Copper piping. P L KPSW Overall L mm 900 dimensions H mm 680 P mm 90 H Weight kg.5 Overall L mm 0 packed H mm 8 dimensions P mm 96 Weight kg 4 - DESCRIPTION Model Copper/aluminium thermal exchanger Number of rows Frontal surface area m Water capacity Hydraulic connection litres KPSW 0.78 KPSW 0.78 KPSW Electrical motor with internal thermal protection Power supply 0 V / + Earth / 50 Hz Number of speeds Capacitor µf Tangential fan Air filter in class HB polypropylene (UL94) - Washable Flexible connection tubes accessory Condensate drain pan expanded polystyrene, supplied with drainage hose End fitting OD mm Wire remote control version Infrared remote control version
5 5 - ACCESSORIES 5. - FLEXIBLE TUBES for hydraulic connection Set of insulated metal flexible tubes (these tubes do not crush when bent). Code Length (mm) air handler side fe fe Connections installation side 5. - ACTIVE CARBON FILTER Code WAY VALVE + BY-PASS Code KVS.6. - "On/Off" motor 0 VAC. - To be assembled outside the unit. Note: The valve is supplied without connection or tube. This valve kit can be mounted on all models and is obligatory for cold water use. If this valve is not installed, there is a risk of condensation forming on the machine when it is switched off by the thermostat REMOTE CONTROLS (for the wire remote control version) Model KPSW Manual remote control RCC 0 automatic remote control for -pipe units Change/over sensor with bracket for RCC (may be used as an air recirculation sensor) Air temperature sensor in box for RCC Note: "On-Off" action on valve, 0 VAC (accessory) or action on ventilation. A - MANUAL REMOTE CONTROL Code The operating mode is selected manually by a switch on the front of the control unit. Technology : electromechanic. Power supply : 0 Vac Set-point adjustment range: 8 / 0 C (possibility of mechanical limitation by jumpers on the knob) "On-Off" action Control differential : K Operating temperature : 0 / 50 C Relative humidity : < 95% Protection class : cl. II IP :0 Colour : White RAL 900 Operating switch with fan speed selection Temperature setting knob Heating / cooling selector switch 5
6 B - AUTOMATIC REMOTE CONTROL Type RCC 0 - code Selection of the operating mode is done automatically. For the -pipe units capable of heating and cooling operation, a change-over sensor must be connected (accessory, code ) to the installation on the water piping. This change-over sensor can be replaced by a potential-free contact (not supplied), the closing of which causes changeover to cooling mode. There is a possibility to connect a remote air temperature sensor, bare (accessory, code ) or box mounted (accessory, code ). Permanent or slaved ventilation. Mode change is possible (Eco or Stand-by) by an external potential-free contact (not supplied). Technology : electronic. Power supply : 0 Vac Set-point adjustment range: 8 / 0 C (possibility of mechanical limitation by jumpers on the knob) "On-Off" action Heating differential : adjustable or 4 K Cooling differential : adjustable 0.5 or K Neutral zone (on RCC 0) : adjustable or 5 K Setpoint in "Eco" mode : 6 C in heating mode 8 C in cooling mode Setpoint in "Standby" : 8 C in heating mode Operating temperature : 0 / 50 C Relative humidity : < 95% Protection class : cl. II IP :0 Colour : White RAL 900 Heating on indicator light Ventilation on indicator light Cooling on indicator light Temperature setting knob Operating switch with fan speed selection C - TEMPERATURE SENSOR (BARE) Code For RCC type remote control. Use: - change over sensor (equipped with a tube retaining clip) for "-tube" appliances may operate in heating and cooling mode, - air recirculation sensor. Thermistance type CTN kω at 5 C. IP 65 - protection class: cl. II. D - BOX-MOUNTED AIR TEMPERATURE SENSOR Code For RCC remote controls. Enables the control unit to be placed outside the room to be air conditioned. Thermistance type CTN kω at 5 C. The unit is mounted in a box similar to the remote control (IP 0 - protection class: cl. II - colour: white RAL 900). Due to our policy of continuous development, our products are liable to modification whitout notice. 6 R.D. 8 Reyrieux BP 060 Trévoux CEDEX France Phone Fax R.C.S. Bourg-en-Bresse B
CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT
TECHNICAL INSTRUCTIONS CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 6 2 pipes 6.00 kw 7.70 kw CWX 8 2 pipes 8.00 kw 10.50 kw CWX 10 2 pipes 9.92 kw 13.00 kw November 2008 10 12
More informationCWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling
TECHNICAL INSTRUCTIONS CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 3 pipes.60 3.9 pipes + electric heating.08.96 +.5 pipes.08.5 CWX 5 pipes.70 5.70 pipes + electric heating.3 5.3 +.50
More informationCHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw
TECHNICAL INSTRUCTIONS CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw CHG 1 CHG 1 8. kw. kw.7 kw 1. kw April 7 19 - GB - 2 MARKING This product marked conforms to the essential
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More informationR 407 C. > in industrial application. Always very much appreciated for special installations these units shown their powers :
SINGLEPACKAGE CONSOLE UNITS, MONOSPLIT, AIR CONDENSING UNITS APPLICATIONS COMMERCIAL SECTOR CONSOLE UNITS AIR CONDENSING UNITS Always very much appreciated for special installations these units shown their
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationPHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW
TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.00 kw -. kw PHRT.0 kw /.0 kw
More informationTECHNICAL DATA & SERVICE MANUAL MTF94C5TAA
TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA 0.8180.472.0 07/2005 Page 1. SPECIFICATIONS 3 1-1 Unit Specifications 3 1-2 Major Component Specifications 4 2. DIMENSIONAL DATA 6 2-1 Unit Dimensions 6 3. ELECTRICAL
More informationDUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX
Duct unit DUCTIMAX Medium available static pressure ducted hydronic units DUCTIMAX - 8 kw NEW PRODUCT JUNE 05 Performance and compactness in recessed ceiling installations ERGO Supervision Plus -pipe system
More informationCarisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT
Made in Italy Air Conditioning High Wall Fan Coil -ECM QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction
More informationCarisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.
Made in Italy Air Conditioning Wall-mounted Fan Coil QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction Version
More informationEEDEN technical data. Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT
EEDEN08-424 technical data Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT EEDEN08-424 technical data Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT Fan coil units 1 Hydronic Systems Fan coil units 1 F
More informationSABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM
Air Conditioning Fan Coil Units ICIM ISO 900 - Cert. n 0545/2 Unit heaters Radiant panels Fan coils Air handling units Flues SABIANA ENVIRONMENTAL COMFORT Sabiana is the fan coil that continues the Sabiana
More informationHigh wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue
High wall fan coils Climmy FHW/FHW-ECM Technical Catalogue Versions and Main components MODELS WITHOUT ELECTRIC HEATER All versions are available without valves, with 2 way valve or with 3 way valve fitted
More informationTechnical Manual. New Water Cassette. Series BREZZA DOUBLE
Technical Manual New Water Cassette Series BREZZA DOUBLE AERTESI srl Cassetta BREZZA DOUBLE Tecnical manual AER.MT.I.BREDOPPIA.000.02.15 Pag.2 INDEX 1-INTRODUCTION 4 2- WORKING CONDITION LIMITS..4 3- COANDA
More informationCLIMACIAT AIR COMPACT
Air handling units The modular and ultra-slim AHU to guarantee perfect solution Ideal for a compact installation Available in single-flow or aligned or adjacent dual-flow versions Air flow: up to 6 000
More informationBlower-YEFB-020-3R-1maxVel
YEFB DUCTED UNIT GENERAL FEATURES Structure It is made of 1,0 mm thick galvanised steel. Despite this thickness, a special tool for production allowed to keep a good stiffness, in order to reduce the risk
More informationRoom Temperature Controller
3 22 Room Temperature Controller for two-pipe fan coil units with electrical heater RCC2 Outputs for on / off valve actuator and electrical heater Output for three-speed fan Control depending on the room
More informationTECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT
1. GENERAL INFORMATION 1.1 Applications page 2 1.2 Operation» 2 1.3 Performances» 2 1.4 Product range» 2 1.5 Selection software» 2 2. DIMENSIONS AND WEIGHTS» 3 3. COMPONENTS 3.1 Structure» 4 3.2 Coils»
More informationTECHNICAL DATA & SERVICE MANUAL
TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: GRF188R5TAA GRF228R5TAA GRF228R7TAA SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. GRF188R5TAA 38.7107.083 GRF228R5TAA 38.7107.084 GRF228R7TAA 38.7107.085
More informationAOF CLIMATISEUR MONOBLOC A CONDENSATION A EAU SINGLE PACKAGED ROOM AIR CONDITIONER WITH WATER COOLED CONDENSER
NOTICE D'UTILISATION OPERATING INSTRUCTIONS BEDIENUNGSANLEITUNG F D AOF AOF 15 AOF 25 AOF 55 CLIMATISEUR MONOBLOC A CONDENSATION A EAU SINGLE PACKAGED ROOM AIR CONDITIONER WITH WATER COOLED CONDENSER KOMPAKT
More informationWATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED
EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units
More informationUniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016
UniTrane Terminals High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line Product Presentation September 2016 Agenda Product overview Key features Product range Controls Emissions Accessories
More informationFLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.
The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution use Air flow rate: 500 to 8500 m 3 /h is a PLUG & PLAY dual-flow ventilation unit equipped with a highly
More informationAerslim Fancoil unit. Technical information manual. Western Airconditioning B.V. Tel. +31 (0)
Aerslim Fancoil unit Technical information manual Western Airconditioning B.V. Tel. +31 (0) 33 247 78 00 www.western.nl INDEX 1-INTRODUCTION... 2 2-OPERATING RANGE... 2 3-RADIANT PLATE... 2 4-CODE COMPORISION
More informationMAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation
Extensive range of chilled water or direct expansion systems Compact and attractive design Energy savings with EC motor and self-regulating control Easy to install Cooling capacity: 10 to 116 k Air flow
More informationTECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA
TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA ARGO 245C / 3SC Cooling only model ARGO 235H / 3HP Heat pump model 0.8180.405.2 09/2006 Table of contents Page A SPECIFICATIONS 1) Unit specifications 3
More informationTHIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM
THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM 0,7 kw 5,2 kw 1,6 kw 10,2 kw 130 m 3 /h 830 m 3 /h SLIM SLIMxx0 vertical with cabinet bottom vertical Available also with feet SLIMxx8 SLIMxx5 SLIMxx4 SLIMxx9
More informationTECHNICAL DATA & SERVICE MANUAL
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: CAF97R5IAA CAF98MR5IAA CAF127R5IAA CAF128MR5IAA CAF187R5IAA SPLIT SYSTEM AIR CONDITIONER Model No. CAF97R5IAA CAF127R5IAA CAF187R5IAA CAF98MR5IAA CAF128MR5IAA
More informationRoom Temperature Controllers
3 021 Room Temperature Controllers for two-pipe fan coil units RCC10 Output for on / off valve actuator Outputs for three-speed fan Control depending on the room or return air temperature (RCC10) Automatic
More informationGeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control.
Plug&Heat heat pump HomeConnect control For residential and tertiary applications Heating capacity (0/- C ): 5 to 9 kw Heating capacity (0/7 C ): 7 to kw Domestic 62 40A hot water Geo Cooling Modular Concept
More information1. Information before installation General terms of delivery, storage and transport
EN Read this manual carefully before installing, maintaining or repairing this device! The symbol indicates important information that must be taken into account in order to avoid risk of personal injury
More informationFans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL Wall mounted fan coil units SYSWALL Wall mounted fan coil units With a tangential
More informationDUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS
EN DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS EBH EDS EBH EDS HIGH PRESSURE UNITS EBH high pressure ducted units and EDS Double Skin units, thanks to their high pressure fan decks, permit to satisfy
More informationSERVICE MANUAL AIR CONDITIONER SPLIT TYPE
FILE No. A90-961 SERVICE MANUAL AIR CONDITIONER SPLIT TYPE WAY CASSETTE TYPE RAV-133TU-PE/RAV-13A-PE RAV-163TU-PE/RAV-18A-PE Printed in UK Dec 1996 s CONTENTS 1. SPECIFICATION...3. CONSTRUCTION VIEWS...5
More informationEXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction
Reducted footprint Dual-wall construction Built-in variable frequency drive PLC control Variable speed condenser fan Cooling capacity: 5 to 50 kw Air flow: 1 000 to 12 000 m 3 /h ErP READY Use Precision
More information42AM. Air heaters PRODUCT SELECTION DATA
PRODUCT SELECTION DATA The best solution for heating large spaces Ensures buildings warm up ultra-fast Excellent diffusion via patented JET+ double deflection technology Air heaters 4AM Translation of
More informationGalletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better
www.galletti.it Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing 2012 Create value to design better A guide to choosing The group It s 1961 and Galletti with its Jolly copper
More informationControl Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW
1 212 Double thermostat Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW RAZ-TW... 2-position control thermostat and thermal reset limit thermostat with singlepole
More informationFAN COIL UNITS LASER / LOW BODY / CONCEALED
SAPHIR TECHNICAL LITERATURE FAN COIL UNITS LASER / LOW BODY / CONCEALED Energy Saving Technology EST (Energy Saving Technology) is applied to the Johnson Controls fan coil units and cassette units. It
More informationTopVent Design Handbook
TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit
More informationCIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet
Attractive design, Compact and quiet Many customisable configurations possible For indoor installation New reliable technologies Version with Plug and Cool hydraulic module Cooling capacity: 23 to 140
More informationSIGMA PRISMA LOW BODY CONCEALED
EN SIGMA PRISMA LOW BODY CONCEALED EST EST (Energy Saving Technology) is applied to the EURAPO fan coil units and cassette units. It permits to obtain extremely low electrical absorption and a continuous
More informationQZHW Fan Coil Unit. Key features. Specifications
Key features High wall installation Cooling ( pipes) Low noise level Electrical heating coil ECM version for low energy consumption QZHW is a high wall fan coil unit available in sizes and many different
More informationCAW Ceiling-mounted fan heaters for hot water
Ceiling-mounted fan heaters for hot Ceiling-mounted fan heaters for hot Ceiling-mounted fan heaters for hot ceiling-mounted fans are used for heating entrances, warehouses, industrial premises, workshops,
More informationpanel filters with filtering class G4. Supply filter F7 can be supplied with the few models.
AIR HANDLING UNITS WITH HEAT RECOVERY Series Series VUT 350 PE EC VUT 600 PE EC VUT 1000 PE EC VUT 2000 PE EC VUT 3000 PE EC VUT 600 PW EC VUT 1000 PW EC VUT 2000 PW EC VUT 3000 PW EC Ceiling mounted air
More informationpanel filters with filtering class G4. Supply filter F7 can be supplied with the few models.
AIR HANDLING UNITS WITH HEAT RECOVERY Series Series VUT 350 PE EC VUT 600 PE EC VUT 1000 PE EC VUT 2000 PE EC VUT 3000 PE EC VUT 600 PW EC VUT 1000 PW EC VUT 2000 PW EC VUT 3000 PW EC Ceiling mounted air
More informationSYSEFTYS - SYSHRW THE. Water Source Heat Pumps Range N E W. Water cooled. Refrigerant R407C. from 2.1 to 30.0 kw. from 2.7 to 38.1 kw. models.
Air Conditionné Chillers & Heat Centrales Pumps de Water traitement terminals d air Ventilateurs Rooftops Close Sécurité control incendie Water Grilles source et heat Diffusion pumps Composants Direct
More informationRefrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW
Refrigerant R407C CW-AR Water Source Heat Pumps - Vertical Mounting Version Models 07 to 12 2.4 to 3.1kW 1.9 to 2.7kW Some advantages... RAL 9010 painted cabinet 3-fan speeds G2 filter is supplied as
More informationTHERMASREG TR 040 THERMASREG TR 060
THERMASREG TR 040 THERMASREG Temperature controllers, one-step, Mechanical temperature controllers wet room temperature controllers THERMASREG TR 040 with switching output and stainless steel capillary
More informationSPLIT SYSTEM AIR CONDITIONER
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: MRAF99R5IAA MRAF129R5IAA MPAF99R5IAA MPAF129R5IAA SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. MRAF99R5IAA 38.7104.065 MRAF129R5IAA 38.7104.062 MPAF99R5IAA
More informationNEW RANGE OF WARM AIR CURTAINS
NEW RANGE OF WARM AIR CURTAINS stay connected and informed in real time www.france-air.com CONTENTS SELECTION GUIDE 3 HARMONY ONE EVO Compact single-phase warm air curtain 4 REGULATION 5 HARMONY Visible
More informationUse. For 2-pipe fan coils
3 015 RAB11 Room thermostats For 2-pipe fan coils RAB11.1 RAB11.. Room thermostat with manual switch for heating or cooling mode and fan function 2-position control Manual 3-speed fan switch Switching
More informationCompact and silent Scroll compressors All-season operation
Compact and silent Scroll compressors All-season operation Cooling capacity: 40 to 161 kw 410a Cooling only Use The new generation of CONDENCIAT condensation units is the solution for all split-system
More informationQTS SELECTION TECHNICAL BOOKLET
EN QTS SELECTION TECHNICAL BOOKLET Bi2 FAN RADIATORS AND FAN COILS Italian company established in 1956 2 Bi2 Bi2 TABLE OF CONTENTS 1 Range of system terminals... 6 1.1 Cabinet system terminals... 6 1.2
More informationSLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual
u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications
More informationComfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W
Comfort Ceiling Fan Coil System INDULVENT ec NEW Draught-free ambient air distribution with cooling capacity up to 2600 W Low sound power levels Only electrical, cooling water and condensate connections
More informationSeries VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.
AIR HANDLING UNITS WITH HEAT RECOVERY Series VUT PE EC Series SAS908 control panel SAS908 control panel Ceiling mounted energy saving Air Handling Units (AHU) with the air capacity up to 4000 m 3 /h and
More informationFan coil units EPCE04-25A
Fan coil units EPCE04-25A Product portfolio 2 Fan Coil FWV FWL FWM Reference 2-pipe 0 1 2 3 4 5 6 7 8 9 10 11 kw 4-pipe 2 4 6 8 10 12 14 16 18 20 22 24kW FWD 2-pipe 4-pipe Cooling Heating Pictogrammes
More informationCat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE
Cat. N STOP & GO automatic resetting 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat. N (s) : 4 062 88 / 4 062 89 CONTENTS PAGE 1. Description - Use... 1 2. Product
More informationART-U 1-4 kw. Design fan coil unit with a minimum depth of 10 cm only and BLDC motor. Fan coil ART-U PLUS. Design-driven innovation NEW
Fan coil ART-U NEW PRODUCT Design fan coil unit with a minimum depth of 10 cm only and BLDC motor ART-U 1-4 kw Available from SEPTEMBER 2018 Design-driven innovation BLDC motor Tangential fan Supervision
More informationRoom Temperature Controller
3 022 Room Temperature Controller for two-pipe fan coil units with electrical heater RCC20 Outputs for on / off valve actuator and electrical heater Output for three-speed fan Control depending on the
More informationSplit inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45
Plug & Heat heat pump Quick and easy to install For new homes or boiler backup operation 50 HFC R410A CERTIFIED BY CERTITA Heating capacity: 5.5 to 22 kw option CERTIFIED BY CERTITA 30/35-40/45 USE The
More information1. Information before installation General terms of delivery, storage and transport
EN Read this manual carefully before installing, maintaining or repairing this device! The symbol indicates important information that must be taken into account in order to avoid risk of personal injury
More informationAIR-CONDITIONER SERVICE MANUAL
FILE NO. A90-9608 SERVICE MANUAL AIR-CONDITIONER S SPLIT BUILT-IN DUCT TYPE RAV-362B-PE/ RAV-462B-PE/ SPLIT CEILING TYPE RAV-362C-PE/ RAV-462C-PE/ SPLIT CASSETTE TYPE RAV-362U-PE/ RAV-462U-PE/ PRINTED
More informationELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems
Technical Bulletin BT13F002GB-04 ELFODuct MP New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems ELFODUCT MP 15-71 SERIES SERIES RECOMMENDED FOR
More informationTECHNICAL DATA & SERVICE MANUAL
TECHNICAL DATA & SERVICE MANUAL HEAT PUMP MODELS INDOOR UNIT: MPAF188R5TAA MPAF228R5TAA COOLING MODELS MPAF188C5TAA MPAF228C5TAA SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. MPAF188R5TAA 38.7104.033
More informationQZB "Standard" comfort fan coil
Key features Vertical or horizontal installation Concealed installation or with decorative cabinet Cooling ( pipes) and heating ( pipes or electrical heating) ECM version for low energy consumption The
More informationSystem architecture. Air treatment Index
System architecture Air treatment Index 88 Index Chilled-water air treatment units Type Range Cooling capacity, kw Heating capacity, kw Air flow, l/s Chilled-water terminal units Cassette Cabinet Concealed
More informationCASSETTE UNIT. Comfort Circle
CASSETTE UNIT Comfort Circle Comfort Circle cassette unit All-round comfort With today's energy prices, building owners are increasingly aware of the need for an efficient climate system to heat or cool
More informationCALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB
4 RESET ON DHW CH FAULT SATK wall-mounted heat interface unit Fitted for connection to DHW storage SATK4 series ACCREDITED CALEFFI 6/4 GB ISO 9 FM 64 ISO 9 No. The latest generation of heat interface units
More informationVEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.
Slim design and acoustic comfort Saves up to 40% floor space Capacity up to 50 kw Free cooling Water misting Use Drycoolers in this range are mainly designed for cooling water or glycol/water mix for:
More information50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control
PRODUCT selection data Wide range of chilled water cabinets Compact and attractive design EC motor for energy savings Auto-adaptive control Easy to install Close Control Unit 50CO Translation of the original
More informationQuatro canal Super-powered climate control for 4-pipe systems
Quatro canal Super-powered climate control for 4-pipe systems Heating, cooling, ventilation. Despite its compact dimensions, the Quatro Canal is a powerful main heating system, cooling unit and ventilation
More informationTECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: CAF94R5 CAF124R5 CAF94R
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: CAF94R5 CAF124R5 SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. CAF94R5 387106979 CAF124R5 387106980 0.8180.361.0 07/2005 IMPORTANT! Please read before
More informationTechnical documentation Fan coil unit
Technical documentation Fan coil unit KL wall and ceiling unit Description Wall unit with casing, top discharge 8 unit sizes at an air volume of 150-1077 m³/h, heating outputs up to 13,4 kw, cooling outputs
More informationFREEDOM 2019.EX CZ - 21/11/18
FREEDOM 2019.EX FREEDOM Freedom of choice in energy source, installation and application Effective at the lowest water temperatures Freedom is super-efficient in combination with any energy source. The
More informationM2Z M NOTICE D INSTALLATION INSTALLATION INSTRUCTION MANUALE D INSTALLAZIONE MANUAL DE INSTALACIÓN AUFSTELLUNGS- HANDBUCH INSTRUÇÕES DE INSTALAÇÃO
(Etiquette signalétique) NOTICE D INSTALLATION INSTALLATION INSTRUCTION MANUALE D INSTALLAZIONE MANUAL DE INSTALACIÓN AUFSTELLUNGS- HANDBUCH INSTRUÇÕES DE INSTALAÇÃO F I E D P M2Z M MODULE 2 ZONES MIXTE
More informationUCS UCS/M UCS/H UCS900
EN UCS UCS/M UCS/H UCS900 EST EST (Energy Saving Technology) is applied to the EURAPO fan coil units and cassette units. It permits to obtain extremely low electrical absorption and a continuous modulation
More informationFWV 04 FWL 05 FWM 06 FWB 07 FWD 08. Control 09. Accessories 10. Daikin Europe N.V.
Daikin has a worldwide reputation based on over 80 years experience in the successful manufacture of high quality air conditioning equipment for industrial, commercial and residential use. Daikin Europe
More informationHigh temperature air-to-water heat pumps
Designed to replace conventional boilers and produce domestic hot water 4 High temperature hot water (+65 C) 4 Winter operation (-20 C) 4 High energy efficiency (CP) 4 Compact and quiet 4 Scroll compressors
More informationAmendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV
Amendment Sheet Code : M5ACV-2005-0002 Date : 08-05-2006 Superceded : M5ACV-2005-0001 Nomenclature Production spec variation Type of ref. connection X : Not applicable Electrical A : 220-240V/1Ph/50Hz
More informationFan Coil Range HYDRONIC TERMINALS
Fan Coil Range HYDRONIC TERMINALS This document can be subjected to variations. Descriptions, performance data, images and diagrams are indicative only. For further information contact Climaveneta Comunications/Marketing
More informationCMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL
CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years
More informationHT V2 HT Split
Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single
More informationHomepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK
Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK SUPPLY AND EXTRACT AIR UNIT WITH HEAT EXCHANGER AND HEAT RECOVERY, SECONDARY AIR OPTION, FOR
More informationMHCFC4W Chilled/Hot Water Cassette Fan Coil
MHCFC4W-16-01 Chilled/Hot Water Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.1 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 48,000 BTUH Multiaqua
More informationMHCFC4W Chilled/Hot Water Cassette Fan Coil
MHCFC4W-04-01 Chilled/Hot Water Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 12,000 BTUH Multiaqua
More informationMHCFC4W Chilled/Hot Water Cassette Fan Coil
MHCFC4W-08-01 Chilled/Hot Water Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.1 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua
More informationELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems
Technical Bulletin BT13F002GB-00 ELFODuct MP New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems ELFODUCT MP 15-71 SERIES SERIES RECOMMENDED FOR
More informationRAYPAK HOT WATER & HEATING
All copper & bronze construction On/Off & modulating models High temperature applications RAYPAK HOT WATER & HEATING Raypak is a compact, efficient heating design which is the ideal way to heat large quantities
More informationTECHNICAL DATA & SERVICE MANUAL
TECHNICAL DATA & SERVICE MANUAL REVE DCI HPL/SCL 0.8180.615.01 06/2012 Pagina 1 Table of contents Page A SPECIFICATIONS 1) Unit specifications 3 2) Major Component specifications 4 B OPERATING RANGE 6
More informationSemi flush-mount room thermostat
3 078 Semi flush-mount room thermostat for CAV / VAV heating and cooling systems for AHU systems for universal heating and cooling systems RDU340 Modulating PI control Control depending on the room or
More informationEvaporadoras Hidrónicas
Evaporadoras Hidrónicas Rev. 215-6-4 Rev. 214-9-5 Clima-Flex, S.A. de C.V. Av. Central # 285 Parque Logístico - Delegación La Pila C.P. 78422, San Luis Potosí, México Tel. 52 (444) 161-543 /ClimaFlexMexico
More informationThe fan is switched to the selected speed via control output Q1, Q2 or Q3.
5RRP7HPSHUDWXUH&RQWUROOHU IRUIRXUSLSHIDQFRLOXQLWV 5&& 2XWSXWVIRURQRIIYDOYHDFWXDWRUV 2XWSXWVIRUWKUHHVSHHGIDQ &RQWUROGHSHQGLQJRQURRPRUUHWXUQDLUWHPSHUDWXUH 2SHUDWLQJPRGHVQRUPDOHQHUJ\VDYLQJDQGIURVWSURWHFWLRQRU2))
More informationDIRECT DRIVE BLOWER COILS
DIRECT DRIVE BLOWER COILS Horizontal HDY Vertical VDY Upgrade to IEC s Direct Drive Blower Coils Energy Efficient Energy Efficient Easy Easy to Installation Install Extended Service Life Engineered to
More informationPreliminary Release. Room Temperature
3 057 Preliminary Release RDF110 RDF110/IR RDF110.2 RDF110.2/IR Room Temperature Controllers with LCD for 2-pipe fan coil units for compressors in DX-type equipment RDF110 Output for an on / off valve
More informationWe have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems
We have some on stock... GEA MultiMAXX Prompt Unit Heaters Data & Facts GEA Heat Exchangers / HVAC Systems Short Description/Overview of Capacity Quick solution for heating of industrial halls For more
More informationConditioning your ambient, maximising your comfort.
Centrifugal fancoils for surface mounting or recessed installation. Cooling capacity from 0,6 to 7,6 kw and heating capacity from 0,8 to 9 kw. Air flow from 100 to 1500 m3/h. Cassette with radial fan.
More information