ENERGY RECOVERY VENTILATOR
|
|
- Lorraine Wood
- 6 years ago
- Views:
Transcription
1 ENERGY RECOVERY VENTILATOR ERV 60H Part no. 606 (TOP PORTS) Part no. 60 (SIDE PORTS) 5 to 05 CFM (0. in. w.g.) VB0073 AN INGENIOUS AIR EXCHANGE SOLUTION THAT S AS VERSATILE AS IT IS COMPACT! Configured with factory built vertical or horizontal ports, the vänee ERV 60H is the most versatile 00-cfm unit available on the market today. Among its exclusive features, this unit is equipped with integrated balancing and backdraft dampers in its exhaust to outside and fresh air supply ports. For a standard installation, there is no need to balance the unit*, thanks also to its twin high-pressure blowers. Its operation can be interlocked with an existing furnace without adding an extra relay. Also, for more convenience, its latches can be relocated on its front (as shown on unit picture). This compact, lightweight, and powerful unit is the ideal choice for small single-family homes, high rise residential building and other limited space applications. *To avoid balancing, the difference between stale air ducts total length and fresh air ducts total length must not exceed 50 ft. Versatile horizontal or vertical port configuration Removable terminal block to ease auxiliary wall control connections Integrated pressure taps, if balancing required by building code ENERGY STAR qualified REPAIRS AND MAINTENANCE All parts of the vänee ERV 60H that could need maintenance can be removed in less than 5 minutes, allowing direct access for easy repairs. The PSC motors are permanently lubricated. Finally, the removable electrical drawer with pull-out PCB assembly allows easy access for maintenance of major sub-components. WARRANTY The vänee ERV 60H is protected by a 2-year warranty on parts only. The energy recovery core is covered by a 5-year warranty, with the original proof of purchase. Available at: Controls This unit is very simple to operate. Once it is installed, press on its push button, located on on the bottom of the unit, to activate it. Press once for low speed, once again for high speed, and once more to stop it. The following main controls are available: - Platinum programmable digital control with SMART mode no Deco-Touch digital control no Bronze no Lite-Touch Bronze no Simple-Touch Bronze no The following optional auxiliary controls can also be added: - 20-min. lighted push button no min. mechanical timer no For more details about controls, refer to their specification sheet on vanee.ca. Options Complete line of registers and diffusers Electric duct heater Dual exterior hood kit (including the Tandem transition), part no. 690 Homeshield Defrosting System The vänee ERV 60H uses a unique defrosting method. No negative pressure is created by air exhausted to the outside, as the air is recirculated into the house, helping to prevent any backdraft. STALE AIR FROM FILTERED AIR TO VF0037 Energy Recovery Core Dimensions: 9/8 x 37/6 x 6 7/8 (8,6 cm x 3, cm x 7,3 cm) Exchange surface: 56 ft.2 (5.2 m2) Weight: 9.25 lb. (,2 kg) Material: Polymerized paper Type: Crossflow and counterflow core Warranty: 5 years Requirements and Standards OUTSIDE DEFROST CYCLE (IN MINUTES) Complies with the UL 82 requirements regulating the installation of Energy Recovery Ventilators Complies with the CSA C22.2 no. 3 Standard applicable to ventilators Complies with CSA C requirements regulating the installation of Energy Recovery Ventilators Technical data was obtained from published results of tests relating to CSA C39 Standards HVI certified and ENERGY STAR qualified oc THAN -5 of THAN 23 DEFROST/ OPERATION NO DEFROST -5 TO TO -7 9/ /22
2 DIMENSIONS: VÄNEE ERV 60H (PORTS ON SIDES) ALL PORTS FIT (02 mm) 27 /6 (688 mm) 22 9/6 (57 mm) 9 3/6 (503 mm) 6 (52 mm) /6 (30 mm) VK0057A SPECIFICATIONS : FRESH AIR TO PORT 2 : EXHAUST AIR FROM PORT VENTILATION PERFORMANCE EXTERNAL STATIC PRESSURE NET GROSS EXHAUST PA IN. W.G. L/S CFM M 3 /H L/S CFM M 3 /H L/S CFM M 3 /H ENERGY PERFORMANCE NET C F L/S CFM M 3 /H POWER CONSUMED WATTS RECOVERY EFFICIENCY APPARENT EFFECTIVENESS LATENT RECOVERY/ MOISTURE TRANSFER HEATING COOLING TOTAL RECOVERY EFFICIENCY (5 mm) 3 : FRESH AIR FROM OUTSIDE PORT : EXHAUST AIR TO OUTSIDE PORT VÄNEE ERV 60H (PORTS ON TOP) 93 6 (503 mm) 6¼ (3 mm) NOTE: All specifications are subject to change without notice. Model: ERV 60H Core filters: 30 ppi washable foam Speed control on unit: Low & high speeds. Part number top ports: x 6.75 x 0.5 (22,2 cm x 7,2 cm x,3 cm) Other modes available with main and Part number side ports: 60 Housing: Pre-painted steel optional wall controls. Insulation: Expanded polystyrene Energy recovery core: Total assembled weight (including Mounting: Suspension by chains and springs - Heat exchange surface area: 56 ft. 2 (5.2 m 2 ) polymerized paper core): 5 lb. (20. kg) - Type: Crossflow and counterflow Supply and exhaust blower motor: 2 motors - Material: Polymerized paper Oval shaped ports; fit 5 diameter ducts - Protection type: Thermally protected Unit electrical characteristics: - Insulation class: B 20 volts, 60 Hz, ampere, 0 watts VK0058A ALL PORTS FIT (57 mm) 23¾ (603 mm) : FRESH AIR TO PORT 2 : EXHAUST AIR FROM PORT 3 : FRESH AIR FROM OUTSIDE PORT : EXHAUST AIR TO OUTSIDE PORT (02 mm) 6 (52 mm) 6 (30 mm) 2½ (6 mm) Project: Location: Part Number: Qty.: Submitted by: Date: REMARKS 550 Lemire Blvd., Drummondville, Qc, Canada J2C 7W9 - Tel.: Fax / PRODUCT SHEET NO. 9053
3 HEAT RECOVERY VENTILATOR HRV 60H Part no. 602 (TOP PORTS) Part no. 600 (SIDE PORTS) 39 to 98 CFM (0. in. w.g.) VB0072 AN INGENIOUS AIR EXCHANGE SOLUTION THAT S AS VERSATILE AS IT IS COMPACT! Configured with factory built vertical or horizontal ports, the vänee HRV 60H is the most versatile 98-cfm unit available on the market today. Among its exclusive features, this unit is equipped with integrated balancing and backdraft dampers in its exhaust to outside and fresh air supply ports. For a standard installation, there is no need to balance the unit*, thanks also to its twin high-pressure blowers. Its operation can be interlocked with an existing furnace without adding an extra relay. Also, for more convenience, its latches can be relocated on its front (as shown on unit picture). This compact, lightweight, and powerful unit is the ideal choice for small single-family homes, high rise residential building and other limited space applications. What s more, it is the only air exchanger of its size that can be upgraded from an HRV to an ERV, simply by changing its core. *To avoid balancing, the difference between stale air ducts total length and fresh air ducts total length must not exceed 50 ft. Versatile horizontal or vertical port configuration Removable terminal block to ease auxiliary wall control connections Integrated pressure taps, if balancing required by building code ENERGY STAR qualified REPAIRS AND MAINTENANCE All parts of the vänee HRV 60H that could need maintenance can be removed in less than 5 minutes, allowing direct access for easy repairs. The PSC motors are permanently lubricated. Finally, the removable electrical drawer with pull-out PCB assembly allows easy access for maintenance of major sub-components. WARRANTY The vänee HRV 60H is protected by a 2-year warranty on parts only. The heat recovery core is covered by a limited lifetime warranty, with the original proof of purchase. Available at: Controls This unit is very simple to operate. Once it is installed, press on its push button, located on on the bottom of the unit, to activate it. Press once for low speed, once again for high speed, and once more to stop it. The following main controls are available: - Platinum programmable digital control with SMART mode no Deco-Touch digital control no Bronze no Lite-Touch Bronze no Simple-Touch Bronze no The following optional auxiliary controls can also be added: - 20-min. lighted push button no min. mechanical timer no For more details about controls, refer to their specification sheet on vanee.ca. Options Complete line of registers and diffusers Electric duct heater Dual exterior hood kit (including the Tandem transition), part no. 690 Homeshield Defrosting System The vänee HRV 60H uses a unique defrosting method. No negative pressure is created by air exhausted to the outside, as the air is recirculated into the house, helping to prevent any backdraft. STALE AIR FROM FILTERED AIR TO VF0036 Heat Recovery Core Dimensions: 3 x 9 x 6 7/8 (33 cm x 8.3 cm x 7.3 cm) Exchange surface: 55 ft.2 (5. m2) Weight: 3.75 lb. (.7 kg) Material: Polypropylene Type: Cross flow Warranty: Limited lifetime Requirements and standards OUTSIDE DEFROST CYCLE (IN MINUTES) Complies with the UL 82 requirements regulating the installation of Heat Recovery Ventilators Complies with the CSA C22.2 no. 3 Standard applicable to ventilators Complies with CSA C requirements regulating the installation of Heat Recovery Ventilators Technical data was obtained from published results of tests relating to CSA C39 Standards HVI certified and ENERGY STAR qualified oc THAN -5 of THAN 23 DEFROST/ OPERATION NO DEFROST -5 TO TO -7 8/25-27 & LESS -7 & LESS 0/22
4 DIMENSIONS: VÄNEE HRV 60H (PORTS ON SIDES) ALL PORTS FITS (02 mm) 27 /6 (688 mm) 22 9/6 (57 mm) 9 3/6 (503 mm) 6 (52 mm) 3¾ (39 mm) /6 (30 mm) SPECIFICATIONS : FRESH AIR TO PORT 2: EXHAUST AIR FROM PORT VENTILATION PERFORMANCE EXTERNAL STATIC PRESSURE NET GROSS EXHAUST PA IN. W.G. L/S CFM M 3 /H L/S CFM M 3 /H L/S CFM M 3 /H ENERGY PERFORMANCE NET C F L/S CFM M 3 /H POWER CONSUMED WATTS RECOVERY EFFICIENCY APPARENT LATENT RECOVERY/ MOISTURE EFFECTIVENESS TRANSFER HEATING COOLING VK0055A TOTAL RECOVERY EFFICIENCY NOT TESTED 2 (5 mm) 3: FRESH AIR FROM OUTSIDE PORT : EXHAUST AIR TO OUTSIDE PORT VÄNEE HRV 60H (PORTS ON TOP) 93 6 (503 mm) 6¼ (3 mm) NOTE: All specifications are subject to change without notice. Model: HRV 60H Core filters: 30 ppi washable foam Speed control on unit: Low & high speeds. Part number top ports: x 6.75 x 0.5 (26.7 cm x 7.2 cm x.3 cm) Other modes available with main and Part number side ports: 600 Housing: Pre-painted steel optional wall controls Total assembled weight (including Insulation: Expanded polystyrene Heat recovery core: polypropylene core): 2 lb. (9 kg) Mounting: Suspension by chains - Heat exchange surface area: 55 ft. 2 (5. m 2 ) and springs - Type/Material: Crossflow/Polypropylene Oval shaped ports; fit 5 diameter ducts Supply and exhaust blower motor: 2 motors Unit electrical characteristics: Drain: /2 (.2 cm) fittings with - Protection type: Thermally protected Volts Frequency Ampere Watts 0 ft. (3 m) PVC drain hose - Insulation class: B Hz VK0056A ALL PORTS FITS (57 mm) 23¾ (603 mm) : FRESH AIR TO PORT 2: EXHAUST AIR FROM PORT 3: FRESH AIR FROM OUTSIDE PORT : EXHAUST AIR TO OUTSIDE PORT (02 mm) 6 (52 mm) 6 (30 mm) 2½ (6 mm) Project: Location: Part no.: Qty.: Submitted by: Date: REMARKS 550 Lemire Blvd., Drummondville, Qc, Canada J2C 7W9 - Tel.: Fax: / PRODUCT SHEET NO. 909
5 HEAT RECOVERY VENTILATOR vänee 90H-V Part no to 57 CFM (0. in. w.g.) VB025 THE NEWEST ADDITION TO OUR POPULAR BRONZE FAMILY The contractor s priority is to offer affordable improved indoor air quality to the customer. At vänee, we also share this vision: provide a reliable product that will ensure the homeowner a healthier environment. The 90H-V offers all the basic features for the new construction market, such as integrated balancing dampers and a defrosting system without negative pressure. Moreover, all aspects of its design were thought to ease balancing of air flow and simplify installation; it also offers easy access to electronic components. Designed with 2 PSC motors, the 90H-V improves indoor air quality and reduces excess humidity, ensuring a continuous supply of fresh air from outside into the house. Faster and easier installation of insulated flexible ducts with practical straps Integrated balancing dampers Easy to access electronic module Homeshield defrosting system (no negative pressure) Heat recovery core offers greater comfort Designed with 2 PSC high pressure blowers Integrated draining system with antimicrobial coating ENERGY STAR qualified REPAIRS AND MAINTENANCE The 90H-V low power consumption PSC motors are permanently lubricated. The electronic circuit board eliminates electromechanical parts, reducing repair time to a minimum. WARRANTY The 90H-V unit is protected by a complete 2-year warranty on all parts. The heat recovery core is covered by a limited lifetime warranty, with the original proof of purchase. Available at : Controls This unit is very simple to operate. Once it is installed, press on its push button, located under the unit, to activate it. Press once for low speed, once again for high speed, and once more to stop it. The following main controls are also available: - Digital control Deco-Touch* no Lite-Touch Bronze no Bronze no * Recirculation mode not available. Also, to 5 of the following optional controls can be added: - 20-min. Lighted push button no min. Mechanical timer no For more details about controls, refer to their specification sheet on vanee-ventilation.com. Options Complete line of registers and diffusers Electric duct heater Homeshield Defrosting System The 90H-V uses a unique defrosting method. No negative pressure is created by air exhausted to the outside, as the air is recirculated into the house, helping to prevent any backdraft. VF006 STALE AIR FILTERED AIR FROM TO Heat Recovery Core OUTSIDE C F THAN -5 THAN 23 DEFROST CYCLE DEFROSTING MIN./ OPERATING MIN. NO DEFROST -5 TO TO -7 7 / / 22 Dimensions: 0 x 0 x.25 (25. cm x 25. cm x 36.2 cm) Exchange surface: 00 ft2 Weight: 7.26 lb (3.3 kg) Material: Polypropylene Type: Cross flow Warranty: Limited lifetime Requirements and standards Complies with the UL 82 requirements regulating the installation of Heat Recovery Ventilators Complies with the CSA C22.2 no. 3 Standard applicable to ventilators Complies with CSA C requirements regulating the installation of Heat Recovery Ventilators Technical data was obtained from published results of tests relating to CSA C39 Standards HVI certified and ENERGY STAR qualified
6 DIMENSIONS AND SERVICE CLEARANCE: VÄNEE 90H-V 23 9 /6 (599 mm) 2 ¹/6 (53 mm) 2 9 /6 (62 mm) 22 ½ (572 mm) /6 (97 mm) 7 7 /6 (89 mm) VK0066A /6 (358 mm) 5 /6 (380 mm) VENTILATION PERFORMANCE EXT. STATIC PRESSURE NET GROSS POWER CORD 3 FT EXHAUST Pa in. w.g. l/s cfm m 3 /h l/s cfm m 3 /h l/s cfm m 3 /h ¼ (6 mm) EXTERNAL STATIC PRESSURE IN. W.G. (PA = N X 28.36) NOTE: Every port fits 6 round duct. : EXHAUST AIR TO OUTSIDE PORT 2 : FRESH AIR FROM OUTSIDE PORT 3 : EXHAUST AIR FROM PORT : FRESH AIR TO PORT VG0082A GROSS (CFM) EXHAUST (CFM) PCM (L/S = PCM X 0.79) (M 3 /H = L/S X 3.6) ENERGY PERFORMANCE NET C F L/S CFM POWER CONSUMED WATTS RECOVERY EFFICIENCY APPARENT LATENTE/RECOVERY MOISTURE EFFECTIVENESS TRANSFER HEATING NOTE: All specifications are subject to change without notice. SPECIFICATIONS Model: 90H-V Insulation: Expanded polystyrene Housing: pre-painted steel Part number: Mounting: Suspension by chains and springs Heat recovery core: Total assembled weight (including 2 PSC motors (supply and exhaust blower - Heat exchange surface area: 00 ft 2 (9.3 m 2 ) polypropylene core): 52.0 lb. (23.6 kg) motors) - Type: Cross flow Ovale shaped ports: fit 6 round ducts - Protection type: thermally protected - Material: Polypropylene Drains: /2 (.2 cm) fittings with - Insulation class: F 0 ft (3 m) PVC drain hose Speed control on unit: Unit electrical characteristics: Core filters: 2 washable MERV 7 - Low and High speed Volts Frequency Ampere Watts 9.2 x.25 x Other modes available with Hz.0 25 (23. cm x 36.2 cm x 9.6 cm) Lite-Touch or Deco-Touch main control Project: Location: Part no.: Qty.: Submitted by: Date : REMARKS 550 Lemire Blvd., Drummondville, Qc, Canada J2C 7W9 - Tel.: Fax: /0 FICHE TECHNIQUE 98
HEAT RECOVERY VENTILATOR
HEAT RECOVERY VENTILATOR CONSTRUCTO 1.0 HRV Part no. 41502 (TOP PORTS) Part no. 41500 (SIDE PORTS) 39 to 98 CFM (0.4 in. w.g.) VB0069 AN INGENIOUS AIR EXCHANGE SOLUTION THAT S AS VERSATILE AS IT IS COMPACT!
More informationBROAN ERVS100 Part no. ERVS100S CFM (0.4 in. w.g.)
BROAN ERVS100 Part no. ERVS100S 65-105 CFM (0.4 in. w.g.) Product balancing The ERVS100 is equipped with 2 high static pressure blowers and is factory balanced. At installation, the ERVS100 will remain
More informationIndoor Air Quality Product Brochure.
Indoor Air Quality Product Brochure Ventilation: A vital system for a healthy home All homes require adequate ventilation for the safety of their occupants and to remove excess humidity, airborne pollutants
More informationIndoor Air Quality Product Brochure.
Indoor Air Quality Product Brochure Ventilation: A vital system for a healthy home All homes require adequate ventilation for the safety of their occupants and to remove excess humidity, airborne pollutants
More informationInspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV
Inspir Compact Heat and Energy Recovery Multi-Family HRV/ERV High-Profile Performance & Low-Profile Design Small spaces demand smart technology. Aldes Inspir Compact Heat and Energy Recovery Ventilators
More informationYour complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.
RANGE HOODS ATTIC VENTILATORS AIR EXCHANGERS DELUXE RANGE HOODS For more than 25 years, Venmar Ventilation has been one of North America s leading manufacturers of innovative Indoor Air Quality products
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Energy Recovery Ventilator (ERV) STANDARD 5 YEAR PARTS LIMITED WARRANTY When installed and registered with a complete Maytag system, this product carries a 12 Year All Parts Warranty.
More informationResidential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators
Residential and Commercial HRVs & ERVs Heat Recovery Ventilators & Energy Recovery Ventilators Residential HRVs - Horizontal Recirculating Defrost SUPERVENTOR SERIES Color coded collars easily identify
More informationVentZone Systems VentZone Zoned IAQ with Heat Recovery Kits
RESIDENTIAL SYSTEM SOLUTIONS VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits VentZone Zoned IAQ Kits with Heat Recovery combine a Standard Residential Heat Recovery Ventilator (HRV) with residential
More informationInstallation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)
Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics RNC Series Models RNC95 RNC155 RNC200 RNC10 RNC20 RNC120D RNC5-TPD Residential Heat Recovery Ventilators (HRV) Manufactured
More informationResidential Heat & Energy Recovery
Residential Heat & Energy Recovery Aeromatic Series Standard Residential HRV/ERV 95-215 CFM 2 Discover Heat & Energy Recovery A tightly built, high-performance home is a great way to conserve energy and
More informationVentZone Systems VentZone Zoned IAQ with Energy Recovery Kits
RESIDENTIAL SYSTEM SOLUTIONS VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits VentZone Zoned IAQ Kits with Energy Recovery combine a Standard Residential Energy Recovery Ventilator (ERV) with
More informationLimited Lifetime core warranty. 5-year warranty on balance of unit.
MODEL FEATURES Polypropylene HRV core 3 operating modes Painted galvanized steel case Designed for simple installation by a single person Fully insulated case Limited lifetime warranty on the heat recovery
More informationResidential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators
Residential and Commercial HRVs & ERVs Heat Recovery Ventilators & Energy Recovery Ventilators Residential HRVs - Horizontal Recirculating Defrost SUPERVENTOR SERIES Color coded collars easily identify
More informationFOR MODELS: VENMAR 1.3, 1.8 & 2.6 HE VENMAR 3055 & 5585 COMPACT vänee 1000, 2000 & 3000 HE
Installation Manual FOR MODELS: VENMAR 1.3, 1.8 & 2.6 HE VENMAR 3055 & 5585 COMPACT vänee 1000, 2000 & 3000 HE VB0021 10/2004 04435 Table of contents 1.0 Sizing.............................................................3
More informationProduct Data HRV A10299
HRVCCLHA Heat Recovery Ventilator ERVCCLHA Energy Recovery Ventilator Product Data A10299 The Heat Recovery Ventilation (HRV) and Energy Recovery Ventilator (ERV) systems offered by Carrier are the finest
More informationHEALTHY CLIMATE Heat / Energy Recovery Ventilator
PRODUCT SPECIFICATIONS INDOOR AIR QUALITY HRV / ERV HEALTHY CLIMATE Heat / Energy Recovery Ventilator Bulletin No. 210528 November 2017 Supersedes March 2017 HRV5-150 ERV3-150, -200 HRV3-150-TPD/TPF, HRV5-200-TPD
More informationPurify your world Bring a breath of fresh air to your business with vänee light commercial ERV and HRV solutions the energy-efficient choice for
Purify your world Bring a breath of fresh air to your business with vänee light commercial ERV and HRV solutions the energy-efficient choice for optimal indoor air quality. NO STRESS vänee s robust energy
More informationHeat Recovery Ventilators models:
User s Manual Read and save these instructions. Heat Recovery Ventilators models: 1000 HE 2000 HE 3000 HE 3055 Compact HE 1.3 HE 1.8 HE 2.6 5585 Compact VB0021 VVI, 550 Lemire Blvd., Drummondville, Qc,
More informationMax Series 5 Speed Electronics Lifestyle MAX Digital Control included
Operation and Installation Manual Max Series 5 Speed Electronics Lifestyle MAX Digital Control included 95MAX* 155MAX 155ECM* 155MAXRX 200MAX* 200MAXRX* 195DCS* 195ECM* 300DCS* Residential Heat Recovery
More informationHEAT RECOVERY AND ENERGY RECOVERY VENTILATORS
HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS ENERGY-SAVING VENTILATION SOLUTIONS TO IMPROVE INDOOR AIR QUALITY Quality Features Built Into Every Model Compact
More informationINSTALLATION GUIDE VB0180 VB0148
INSTALLATION GUIDE VENMAR AVS VÄNEE VB0179 VB0180 VB0177 VB0178 Kubix ERV (side ports) Model no. 44113 Kubix ERV (top ports) Model no. 44112 Vïgor ERV (side ports) Model no. 44213 Vïgor ERV (top ports)
More informationUser Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.
User Manual HEAT RECOVERY VENTILATORS MODELS: 1000 HE HE 1.3 2000 HE HE 1.8 3000 HE HE 2.6 3055 COMPACT 5585 COMPACT VB0021 READ AND SAVE THESE INSTRUCTIONS. VVI, 550 Lemire Blvd., Drummondville, QC, Canada
More informationREAD AND SAVE THESE INSTRUCTIONS
User Manual READ AND SAVE THESE INSTRUCTIONS VB0140 vänee 2000 HE 3000 HE VENMAR 1.8 HE 2.6 HE These products earned the ENERGY STAR by meeting strict energy efficiency guidelines set by Natural Resources
More informationSER Models. SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT
SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will operate if connected
More informationProduct Data. ERVCCSVB, ERVCCSHB Energy Recovery Ventilators HRVCCSVB, HRVCCSHB Heat Recovery Ventilators
ERVCCSVB, ERVCCSHB Energy Recovery Ventilators HRVCCSVB, HRVCCSHB Heat Recovery Ventilators Product Data Fig. 1 - ERVCCSVB / HRVCCSVB Fig. 2 - ERVCCSHB / HRVCCSHB A05229 A05330 Energy Recovery Ventilation
More informationProduct Data A05229 A05330 HRV
HRVXX Recovery Ventilators ERVXX Energy Recovery Ventilators ERVXXSVB1100, HRVXXSVB1100 ERVXXSHB1100, HRVXXSHB1100 Product Data A05229 A05330 A10299 ERVXXLHB1200, HRVXXLHB1150, HRVXXLHB1250 HRVXXSVU1157
More informationNovofit 2.0 (Part no )
INSTALLER MANUAL VENTILATION SYSTEMS FOR RESIDENTIAL USE ONLY VB0157 Novofit 1.5* (Part no. 43121) Novofit 2.0 (Part no. 45121) *This product earned the ENERGY STAR by meeting strict energy efficiency
More informationINDOOR AIR QUALITY KITS AND ACCESSORIES /12 Supersedes 05/12
INDOOR AIR QUALITY KITS AND ACCESSORIES 506239 01 Supersedes 05/12 Litho U.S.A. HEALTHY CLIMATE HRV & ERV VENTILATORS INSTALLATION INSTRUCTIONS & HOMEOWNERS GUIDE FOR HEALTHY CLIMATE HEAT RECOVERY VENTILATOR
More informationINDOOR AIR QUALITY KITS AND ACCESSORIES /2014. Supersedes 06/2014
INDOOR AIR QUALITY KITS AND ACCESSORIES 507363-01 08/2014 Supersedes 06/2014 HEALTHY CLIMATE HRV & ERV VENTILATORS INSTALLATION INSTRUCTIONS & HOMEOWNERS GUIDE FOR HEALTHY CLIMATE HEAT RECOVERY VENTILATOR
More informationThe best way to enhance indoor air quality
Purify your world Bring a breath of fresh air to your business with Venmar light commercial ERV and HRV solutions the energy-efficient choice for optimal indoor air quality. No stress Venmar s robust energy
More informationOutside Air Requirements... SOLVED!
Outside Air Requirements... SOLVED! Advancing VentilationTM refresh-0918 September 2018 The Whole Building Ventilation Standard With houses and buildings being built as tightly as possible, we are plagued
More informationHeat Recovery Ventilators (HRVs) Flexibility. in Perfect Form. Improving indoor air quality through better ventilation
Flex 100H Heat Recovery Ventilators (HRVs) Flexibility in Perfect Form Improving indoor air quality through better ventilation An Established Ventilation Solutions Provider Fantech For over two decades,
More informationINSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS
INSTALLATION GUIDE VB0195 MODELS H50100H AND H50100E These products earned the ENERGY STAR by meeting strict energy efficiency guidelines set by Natural Resources Canada and the US EPA. They meet ENERGY
More information10-year industry best core warranty. 5-year warranty on balance of unit.
MODEL TR MODEL FTURES MERV-8 filters Less than 1 watt stand-by power consumption Transformer/relay package allowing simple on/off control Plastic double collars for 6 or 8 direct duct connection (TR300
More informationHRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.
HRV / ERV Heat or Energy Recovery Ventilation Systems You need fresh air, so does your home. Control Your Indoor Air Quality Following the energy crisis of the 1970s, we tended to insulate our homes and
More informationVentilation Solutions IAQ Canada
Ventilation Solutions IAQ Canada 2 IAQ Canada Indoor Air Quality Keep your family safe What s All The Talk About Indoor Air Quality? What The Experts Say: You ve heard it on TV and read about it in magazines.
More informationHRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.
HRV / ERV Heat or Energy Recovery Ventilation Systems You need fresh air, so does your home. Control Your Indoor Air Quality Following the energy crisis of the 1970s, we tended to insulate our homes and
More informationResidential Balanced Ventilation Systems
2017 Broan and S&P Residential Balanced Ventilation Systems Residential balanced ventilation systems introduce fresh air alone, or include Heat Recovery (HRV) or Energy Recovery (ERV) features. Select
More informationFRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %
Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 % 2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed
More informationVentilation Solutions IAQ Canada
Ventilation Solutions IAQ Canada 2 Ventilation Solutions IAQ Ventilation Solutions IAQ 3 Indoor Air Quality Keep your family safe Safeguard Your Home Three easy steps Your home should be safe and comforting,
More informationINSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS
INSTALLATION GUIDE VB0190 Model ERV70S (side ports) VB0192 Model ERV70T (top ports) VB0191 Model HRV70SE* (side ports) VB0193 Model HRV70TE* (top ports) * These products earned the ENERGY STAR by meeting
More informationMODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS
With S&P s TR & TRC (total recovery) Series for all climates, stale room air is exhausted and fresh outdoor air is brought back into the house. These two air streams are directed through a highly developed
More informationContents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...
Contents How to choose Recovery Ventilation type?............................................3 How do HRV, ERV and TRV Systems work?............................................4 Types of installations..............................................................5
More informationINSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220
INSTALLATION GUIDE Horizontal series HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220 INSTALLATION GUIDE Peace of Mind All GeneralAire products are backed by the best limited warranty in the
More informationHeat or Energy Recovery Ventilation System
INSTALLATION MANUAL Heat or Energy Recovery Ventilation System MODELS: FC80 HRV & FC80 ERV This device MUST be installed by a qualified agency in accordance with the manufacturer's installation instructions.
More informationBETTER AIR. BETTER LIFE.
FRESH AIR SYSTEMS BETTER AIR. BETTER LIFE. ENERGY & HEAT RECOVERY VENTILATORS 1 2 3 INDOOR AIR QUALITY 4 5 ENERGY & HEAT RECOVERY 6 CODES & STANDARDS 7 INSTALLATION 8 9 HE SERIES / ADVANCED SERIES 10 11
More informationINSTALLER AND USER MANUAL VENTILATION SYSTEM
INSTALLER AND USER MANUAL VENTILATION SYSTEM VB0230 HRV Solo 2.4 & ERV Quattro 2.4 READ AND SAVE THESE INSTRUCTIONS INSTALLER: LEAVE THIS MANUAL TO THE HOMEOWNER 22068 rev. 01 ABOUT THIS MANUAL This manual
More informationBRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS
USER GUIDE VB0110 BRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS *This product earned the ENERGY STAR by meeting strict energy efficiency guidelines set by Natural Resources Canada and the US
More informationVENTILATION SYSTEMS. Model Numbers HRV-150 HRV-210 ERV-150 ERV-210
Installer Manual VB0065 VENTILATION SYSTEMS Model Numbers HRV-150 HRV-210 ERV-150 ERV-210 06787-04/12/22 Table of Contents 1.0 SERVICE...4 1.1 3-D Drawing...4 1.2 Parts Ordering Chart...5 1.3 Technical
More informationProduct Data VA3B VB5B VC5B. Heat Recovery Ventilators
Product Data VA3B VB5B VC5B Heat Recovery Ventilators VA3B VC5B The Heat Recovery Ventilation (HRV) system offered by Carrier is the finest unit on the market today. The VA3B, VB5B, and VC5B provide efficient
More informationHEAT RECOVERY VENTILATORS MODELS AVS E15 ECM HRV, AVS E15 HRV, AVS E10 HRV AND ENERGY RECOVERY VENTILATOR MODEL AVS E15 ECM ERV
USER GUIDE HEAT RECOVERY VENTILATORS MODELS AVS E15 ECM HRV, AVS E15 HRV, AVS E10 HRV AND ENERGY RECOVERY VENTILATOR MODEL AVS E15 ECM ERV PLEASE READ AND SAVE THESE INSTRUCTIONS Venmar Ventilation ULC,
More informationEnergy Recovery Ventilators
Energy Recovery Ventilators ERV-150 ERV-200 IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will operate
More informationINSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR
INSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR EV130 EV200 EV240 EV300 MODEL: EV200 & EV240 MODEL: EV130 MODEL: EV300 RENEWAIRE.COM ERV EV130, EV200, EV240 AND EV300 ABOUT RENEWAIRE
More informationMODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS
With S&P s TR & TRC (total recovery) Series for all climates, stale room air is exhausted and fresh outdoor air is brought back into the house. These two air streams are directed through a highly developed
More informationINSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR
INSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR EV130 EV200 EV300 MODEL: EV130 MODEL: EV200 MODEL: EV300 RENEWAIRE.COM ERV EV130, EV200, AND EV300 ABOUT RENEWAIRE For over 30 years,
More informationINSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR
INSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR BR70 BR130 MODEL: BR70 MODEL: BR130 RENEWAIRE.COM ERV BR70 AND BR130 ABOUT RENEWAIRE For over 30 years, RenewAire has been a pioneer
More informationWALL CONTROLS MAIN CONTROLS
WALL CONTROLS MAIN CONTROLS Due to the constant evolution of our technologies, it may be possible that some control functions are not compatible to some earlier unit models. For more details, please refer
More informationCOMMERCIAL VENTILATION
COMMERCIAL VENTILATION www.canarm.com hvacsales@canarm.ca HVAC CONTACTS CORPORATE OFFICE / HVAC MANUFACTURING FACILITY 2157 Parkedale Avenue, PO Box 367 Brockville, ON K6V 5V6 Canada Tel: (613) 342-5424
More informationWALL CONTROLS MAIN CONTROLS
MAIN CONTROLS WALL CONTROLS Due to the constant evolution of our technologies, it may be possible that some control functions are not compatible to some earlier unit models. For more details, please refer
More informationCATALOGUE Setting a new standard for energy efficient, clean air homes.
CATALOGUE 2011-12 Setting a new standard for energy efficient, clean air homes www.lifebreath.com Manufacturer reserves the right to change specifications without notice. About Lifebreath For over 25 years
More informationINSTALLER MANUAL RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS
INSTALLER MANUAL VB0234 HRV150FL (part HRV150FLS) HRV190FL (part HRV190FLS) RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS Broan-NuTone LLC; Hartford, Wisconsin www.broan.com 800-558-1711 REGISTER
More informationCOMMERCIAL HRV OPERATION AND INSTALLATION 69-COMHRV FD/DD, 650FD/DD, 700FD/DD, 1200FD/DD
COMMERCIAL HRV OPERATION AND INSTALLATION 455FD/DD, 650FD/DD, 700FD/DD, 1200FD/DD 69-COMHRV 011118 511 McCormick Blvd. London, ON Canada N5W 4C8 General Info/Tech Support: 1 855. 247 4200 Online: www.lifebreath.com
More informationMODELS LT15 & LT20 INSTALLATION INSTRUCTION FOR HEAT RECOVERY VENTILATOR (HRV)
MODELS LT15 & LT20 INSTALLATION INSTRUCTION FOR HEAT RECOVERY VENTILATOR (HRV) Shipping and Packing List Package 1 of 1 contains: 1 - Assembled ventilator 1 - Bag assembly containing: 2 - Drain spout assemblies
More informationHEAT RECOVERY VENTILATORS MODELS AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, NOVOFIT 1.0 AND ENERGY RECOVERY VENTILATOR MODEL AVS ERV EKO 1.
User Guide HEAT RECOVERY VENTILATORS MODELS AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, NOVOFIT 1.0 AND ENERGY RECOVERY VENTILATOR MODEL AVS ERV EKO 1.5 VB0122 VB0123 VB0126 VB0136 PLEASE READ AND SAVE THESE
More informationVENTILATORS VH30100 COMPACT HEAT RECOVERY VENTILATOR VE30100 COMPACT ENERGY RECOVERY VENTILATOR. Installation and Operation Manual.
VENTILATORS MODELS: VH30100 30-100 CFM HRV VE30100 30-100 CFM ERV Features Three operating modes (Intermittent, Continuous and High) 100% variable speed Quick-connect duct collar system Proportional defrost
More informationMiniCore Ventilator (500, 1000) Series Engineering Guide
MiniCore Ventilator (500, 1000) Series Engineering Guide November 2017 V1.0 Johnson Controls, Inc. All rights reserved. TABLE OF CONTENTS Page Functionality and Benefits... 1 Unit Overview... 3 MiniCore
More informationProduct Data HRVCCLHU HRVCCSVC HRVCCLVU. Heat Recovery Ventilators FEATURES
Product Data HRVCCLHU HRVCCSVC HRVCCLVU Heat Recovery Ventilators HRVCCLHU HRVCCSVC The Heat Recovery Ventilation (HRV) system offered by Carrier is the finest unit on the market today. The HRVC provides
More informationProduct Catalog Commercial Solutions US Edition
Product Catalog Commercial Solutions US Edition 2 Introduction Quality products, reliable service and leaders in innovation For more than 30 years, Fantech has been researching, designing and bringing
More informationHRVBBLHU HRVBBSVC HRVBBLVU
SINGLE-PACKAGE ELECTRIC HEATING COOLING UNITS HRVBBLHU HRVBBSVC HRVBBLVU Heat Recovery Ventilators HRVBBLHU HRVBBSVC The Heat Recovery Ventilation (HRV) system offered by Bryant is the finest unit on the
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS ENERGY EFFICIENT FRESH AIR SYSTEM MODELS NRFLOH VSMARTH NRFLOE VSMARTE VB0113 RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS INSTALLER: LEAVE THIS MANUAL WITH THE HOMEOWNER.
More informationTR Series - The Ultimate ERV
TR Series The Ultimate ERV Total Recovery for All Climates Featuring Vent Lights and Premium Grilles Fans s for f Life! The World s Leading Producer of Air Movement Products TR_0810 Indoor Air Quality
More informationOperation and Installation Manual. Models 330ERV 530ERV 730ERV 1230ERV. Commercial Energy Recovery Ventilators (ERV) 69-ComERV
Operation and Installation Manual Models 330ERV 530ERV 730ERV 1230ERV Commercial Energy Recovery Ventilators (ERV) 69-ComERV 032717 Table of Contents The Benefits of ERVs Location of the ERV for Mounting...
More informationNU800, NU1200 & NU1600
P.O. Box 2758 Windsor, Nova Scotia, B0N 2T0 Ph. 902 798 2261 Fax. 902 798 2557 www.nu-airventilation.com Email: nuair@nu-airventilation.com OPERATING, MAINTAINING & INSTALLING YOUR LIGHT COMMERCIAL HEAT
More informationVIGÖR HRV PLUS AND VIGÖR ERV
User Guide VIGÖR HRV PLUS AND VIGÖR ERV VB0147 Model no. 44202 (with top ports) VB0149 Model no. 44212 (with top ports) VB0148 Model no. 44203 (with side ports) VB0150 Model no. 44213 (with side ports)
More informationINSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR
INSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR GR90 EV90 EV90P MODEL: EV90 u PAINTED CASE u LOW VOLTAGE CONTROLS u LINE CORD MODEL: GR90 u GALVANIZED CASE u LINE VOLTAGE u NO LINE
More informationINSTALLATION GUIDE VÄNEE HRV 60H AND ERV 60H
INSTALLATION GUIDE VÄNEE HRV 60H AND ERV 60H Model no.: 41602 (HRV with ports on top) Model no.: 41600 (HRV with ports on sides) VB0072 VB0076 Model no.: 41606 (ERV with ports on top) Model no.: 41604
More informationIAQ VENTILATION SOLUTIONS
IAQ VENTILATION SOLUTIONS HEAT RECOVERY VENTILATORS ENERGY RECOVERY VENTILATORS WHOLE HOUSE HEPA FILTRATION I M P R O V I N G I N D O O R A I R Q U A L I T Y T H R O U G H B E T T E R V E N T I L A T I
More informationProduct Data. HRVCCSVU, HRVCCLVU Single---Package Electric Heating Cooling Units Heat Recovery Ventilators
CCSVU, CCLVU Single---Package Electric Heating Cooling Units Heat Recovery Ventilators Product Data CCSVU CCLVU A92268 A92377 The Heat Recovery Ventilation () system offered by Carrier is the finest unit
More informationSH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT
SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT CAUTION - Before installation, careful consideration must be given to how this system will
More informationINSTALLATION INSTRUCTIONS AND USER MANUAL
INSTALLATION INSTRUCTIONS AND USER MANUAL MODELS HRV 2600* HR 2.6* HEPA 3100* HF 3.1* HEPA 4100* VB0064 NOTES: 1. HRV 2600* model is available in Canada only. 2. HEPA 4100* model is available in United
More informationVENMAR AVS INSTALLATION GUIDE AVS E15 ECM ERV* AVS E15 ECM HRV* AVS E15 HRV AVS E10 HRV 90H-V ECM ERV* 90H-V ECM HRV* 90H-V+ 60H-V+ VÄNEE
INSTALLATION GUIDE VENMAR AVS AVS E5 ECM ERV* AVS E5 ECM HRV* AVS E5 HRV AVS E0 HRV VÄNEE 90H-V ECM ERV* 90H-V ECM HRV* 90H-V+ 60H-V+ V00 *THESE UNITS HAVE A SPECIAL OOTING SEQUENCE, REFER TO PAGE.! RESIDENTIAL
More informationVERTICAL FAN COIL UNITS
VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote
More informationProduct Catalog Commercial Solutions US Edition
Product Catalog Commercial Solutions US Edition 2 Introduction Quality products, reliable service and leaders in innovation For more than 30 years, Fantech has been researching, designing and bringing
More informationSolarSheat Solar Heating and Ventilation. Todd Kirkpatrick-President Your Solar Home Inc. Vaughan, Ontario, Canada
SolarSheat Solar Heating and Ventilation Todd Kirkpatrick-President Your Solar Home Inc. Vaughan, Ontario, Canada www.yoursolarhome.com July 13, 2006 Vision Solar heating in every home and building Mission
More informationInstallation Instructions
HRVCRSVU57 Heat Recovery Ventilator Installation Instructions HRVCRSVU57 A89 NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment,
More informationPA 500/1100V Ultra Quiet Ventilation Fan
SPECIFICATION SHEET PA 500/1100V Ultra Quiet Ventilation Fan Description Ultra quiet ventilation fan with high efficiency, capacitor start motor, Energy Star and HVI 2100 certified. The PA series is UL
More informationEnergy Recovery Total Recovery Ventilators. Balanced Ventilation for Residential and Commercial Buildings. Advancing Ventilation
Energy Recovery Total Recovery Ventilators Balanced Ventilation for Residential and Commercial Buildings Advancing Ventilation ERV-0518 May 2018 Common Ventilation Issues for Homes and Light Commercial
More informationINSTALLATION GUIDE FOR AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, HRV 90H-V ECM AND 90H-V UNITS
INSTALLATION GUIDE FOR AVS HRV EKO.5, AVS CONSTRUCTO.5V, HRV 90H-V ECM AND 90H-V UNITS THIS UNIT HAS A SPECIAL START-UP PROCEDURE, REFER TO PAGE. V09 THIS UNIT HAS A SPECIAL START-UP PROCEDURE, REFER TO
More informationInstallation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier
RXID-AW90A Whole House Dehumidifier with fresh air ventilation Installation Guide Dehumidification Fresh Air Ventilation Compact Size Energy Efficient The whole house dehumidifier integrates highcapacity
More informationLight commercial models
Installation Manual Item #: 422468 Rev Date: 051414 Light commercial models Energy Recovery Ventilators SER 5504 SER 8504 SER 11504 Your ventilation system should be installed in conformance with the appropriate
More informationMODEL TRC TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS
TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS MODEL FTURES MERV-8 filters Transformer/relay package allowing simple on/off control Access doors for easy access to blowers, core and filters
More informationMODELS VA3B, VB5B VC5B
HEAT RECOVERY VENTILATORS MODELS VA3B, VB5B VC5B VA3B VB5B The Heat Recovery Ventilation (HRV) system offered by Bryant is the finest unit on the market today. The VA3B, VB5B, and VC5B provide efficient
More informationINSTALLATION INSTRUCTIONS AND USER MANUAL
INSTALLATION INSTRUCTIONS AND USER MANUAL MODELS HEPA 3.2* and THH.0* VB0049 VB0058 *Patents pending NOTE: HEPA 3.2 model available in Canada only. For United States, use Venmar HEPA 000 model. RESIDENTIAL
More informationPut the V back in HVAC
Put the V back in HVAC V is for Ventilation A system or means of providing fresh air. Webster New Collegiate Dictionary Benjamin Franklin so unwholesome as air in a closed room that has been often breathed
More informationINSTALLATION GUIDE FOR VENMAR AVS CONSTRUCTO 1.5* AND CONSTRUCTO 2.0
INSTALLATION GUIDE FOR VENMAR AVS CONSTRUCTO.5* AND CONSTRUCTO.0 VB056 RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS *This product earned the ENERGY STAR by meeting strict energy efficiey guidelines
More informationGlass Canopy Wall-Mount Hood
Glass Canopy Wall-Mount Hood FHWC3060L S 30" Stainless Steel Features Nominal Width 30" Installation Type Wall Mount Style Stainless Steel / Glass Canopy Air Discharge Vertical Air Delivery (CFM) 400 Blower
More informationCooling Capacity CFM in. w.c. (125 Pa)
93% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 93% AFUE, all models all positions F9MES 50 Hz Product Specifications Certified to leak 2% or less of nominal air conditioning CFM delivered when
More informationINSTALLATION GUIDE FOR VENMAR AVS UNIT CONSTRUCTO 1.0 HRV AND CONSTRUCTO 1.0 ERV
INSTALLATION GUIDE FOR VENMAR AVS UNIT CONSTRUCTO 1.0 HRV AND CONSTRUCTO 1.0 ERV Model no.: 41502 (HRV with ports on top) Model no.: 41500 (HRV with ports on sides) VB0069 VB0070 Model no.: 41506 (ERV
More informationUSER GUIDE MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY rev.
USER GUIDE VB0100 MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS 07919 rev. B About this Guide This guide uses the following symbols
More information