1 Daikin Type K Catalog Incremental Room Conditioner Engineered for flexibility and performance

2 Contents Introduction...3 Heavy Duty Construction for Durability and Quiet Operation...3 Nomenclature...3 Design Features...4 Built With Quality And Long lasting Standard Features...4 Chassis...5 Compressor...5 Heat Transfer Surface...5 Heavy-Duty Construction...5 High Efficiency Condensing Section...5 Outside Air Damper Control...5 Controls...6 Individual Room Conditioning...6 Heat Section...6 Room Cabinets...7 Filtration...7 Wall Boxes...8 Outdoor Louvers...8 Typical Louver Design...8 Engineering Data...9 Performance Data...9 Cooling Capacities at Nonstandard Conditions Heating Capacities at Nonstandard Conditions Dimensional Data...13 Overall Unit Dimensions Size 007 through Units With Electric Heat (Sizes 007 through 014)...13 Units With Hydronic Heat...14 Suggested Piping Arrangements...15 Wall Box and Room Cabinet Dimensions Typical Wiring Diagrams...17 Standard Chassis With Electric Heat & MCO Controls (Sizes )...17 Standard Chassis With Hot Water Heat & MCO Controls (Sizes )...18 Standard Chassis With Steam Heat & MCO Controls (Sizes )...19 Standard Chassis With Electric Heat & 24V Wall Stat (Sizes )...20 Standard Chassis With Hot Water Heat & 24V Wall Stat (Sizes )...21 Standard Chassis With Steam Heat & 24V Wall Stat (Sizes )...22 Accessories and Options...23 Remote Mounted Thermostats...23 Master Unit Control...23 Energy Saving Options...24 Guest Room Control (GRC)...24 Night Setback Control (NSB)...24 Outdoor Air Dampers...24 Engineering Guide Specifications Daikin Type K Incremental Packaged Terminal Room Conditioners are tested in accordance with the Air Conditioning, Heating and Refrigeration Institute (AHRI) Standards 310 and 3. Type K is a registered trademark of Daikin 2013 Daikin. All rights reserved throughout the world. The information contained herein supersedes and replaces previous information published by Daikin and/or its predecessor companies. Illustrations cover the general appearance of Daikin products at the time of publication. Daikin also reserves the right to make changes in design specifications, construction and materials at any time and without notice. Page 2 of 28 Catalog

3 Introduction Heavy Duty Construction for Durability and Quiet Operation The Type K Incremental Room Conditioner was first introduced in 1958 under the Remington brand name, and many of the original units are still in operation today. The Incremental system was the first through-the-wall, self-contained heating and air conditioning system. It is designed to provide ondemand, zoned comfort control for multi-roomed buildings such as hotels, motels, hospitals, nursing homes, apartments, dormitories and offices. Today, Daikin Type K Incremental Room Conditioners continue to set the industry standard for quality. Heavy duty construction, premium engineering, carefully selected components and the highest manufacturing standards assure a quality product. Daikin has a policy of continuous product research and improvement. The Type K unit combines the latest available technology with the long-standing quality features that has made the Type K unit famous. Nomenclature Note: Availability of voltages, heating options, and controls may vary amongst unit sizes. Consult your Daikin representative. P KES C Z 41 Z 12 AR 14 A I C 1 Model Product Category P = PTAC Product Identifier KES = Type K, Cool Chassis Only KEI = Type K Cool Chassis Only, IAQ KEC = Type K Cool Chassis Only, Corrosion Protection KHS = Type K Heat Section Only Design Series 1 = A design 2 = B design Nominal Capacity - Btuh 007 = = = = 14,000 Voltage A = C = G = J = 277/ S = R = Coil Options Z = None Heating Options 35 = 2.5 kw nominal 41 = 3.5 kw nominal 44 = 4.0 kw nominal 48 = 5.0 kw nominal 50 = 7.7 kw nominal 62 = Hydronic - Normally Open Valve (Hot Water) 63 = Hydronic - Normally Closed Valve (Steam) Product Style 1= 1st Style Change SKU A = Stock B = Standard Delivery C = Extended Lead time Color I = Antique Ivory Power Connection A = Junction Box Return Air/Outdoor Air 14 = Bottom Discharge AR = Flat Top Controls 12 = Unit Mounted Manual Changeover (MCO) 24 = Unit Mounted Manual Changeover w/night Setback (NSB) 27 = 24V Wall T'stat w/guest Room Control (GRC) & Night Setback (NSB) 32 = 24V Wall T'stat w/night Setback(NSB) Hand Orientation A = Same Hand Left B = Same Hand Right N = LH Supply / RH Return P = RH Supply / LH Return Z = Not Applicable Catalog Page 3 of 28

4 Design Features Built With Quality And Long lasting Standard Features Heating Section Option for electric resistance or hydronic (steam or hot water) heat. Wall Sleeve Heavy-gauge steel with powder paint coating provides maximum scratch and dent resistance. Minimizes vibration for quieter operation Centrifugal Fans Quieter and able to overcome more external static pressure than propeller fans. Allows more flexible options for architectural louvers or special condenser air treatments Outdoor Louver Heavy-duty, architectural extruded aluminum to resist weathering Heavy-duty Grille Four-way adjustment allows air to be directed where it is needed. Motorized Outside Air Damper Opens when unit is operating to bring in outside air for improved indoor air quality (IAQ). Closes when unit is idle to prevent drafts. Room Cabinet Heavy-gauge steel with powder paint coating provides maximum scratch and dent resistance and minimizes vibration for quieter operation Adjustable Kickplate Adjusts up or down to accommodate new floor coverings Electro-mechanical Controls Reliable and easy to operate. Easy to read with color coding and raised lettering for the visually impaired. Easy-to-read Control Overlay Made of tough polycarbonate material with color impregnated function indicators that won't scratch, peel or fade. Easy to read with color coding and raised lettering for the visually impaired. Page 4 of 28 Catalog

5 Design Features Chassis The concept of individualized room conditioning began many years ago with the Type K conditioner. Over the years this design has become the benchmark for quality and reliability. Continual research and product improvement has allowed Daikin to remain the leader in the sectionalized unit market. Recent design changes have further enhanced the efficiency and durability of the Type K chassis. Many important features have been developed. Those features relevant to this design change are listed below. Figure 1: Chassis Compressor The power plant for the Type K is a high efficiency rotary compressor. It has a proven track record of efficiency and reliability to insure low cost, and continuous service for many years. In addition to its high efficiency, this compressor is protected against thermal overload and is precision balanced for quiet operation. Figure 2: Compressor Heavy-Duty Construction The Type K cooling chassis is constructed of heavy-gauge steel for unsurpassed durability. It is insulated with a waterproof material to prevent sweating. The dense insulation, combined with heavy-gauge steel, results in a unit with very low sound levels. The design of the plug-in device connections allows for quick and easy power disconnection without the use of tools. A convenient amp connector is used to transfer power to the cooling chassis from the control box. The amp connector eliminates hard-wired connections that hinder chassis removal for scheduled maintenance. All unit sizes utilize the same amp connector to facilitate interchangeability of spare chassis. High Efficiency Condensing Section The outdoor condenser section uses a reliable PSC motor to drive an efficient centrifugal fan. Besides being quiet, the centrifugal fan is used to dispose of unwanted condensate generated during the cooling cycle. Condensate draining from the evaporator coil is atomized and entrained by the condenser blower airstream, re-evaporated on the hot condenser coil where it escapes to the outside as vapor. No slinger rings are used and the condensate never comes in contact with the outdoor blower wheel(s). Re-evaporation also lowers condenser temperature and pressure to increase overall cooling efficiency. Figure 3: Condensate Disposal Heat Transfer Surface An advanced coil design is employed in all Type K units. The copper tubes have an internal rifled surface to increase the heat transfer capabilities of the refrigerant. Aluminum fins are mechanically bonded to the copper tubes to insure positive heat transfer. The fins are lanced to increase the air turbulence making the coil extremely efficient. Outside Air Damper Control A motorized outside air damper is standard on all Type K equipment. A toggle switch is located on the cooling chassis to provide control of the damper. The damper can be set to either of two positions: automatic or closed. In the automatic position, the damper will open whenever the indoor fan is energized, except during night setback when it remains closed. In the closed position, the damper will remain closed at all times. The toggle switch is concealed behind the front panel to prevent unauthorized tampering. Catalog Page 5 of 28

6 Design Features Controls The brains to operate the Type K unit are in the control box. The control box is a separate component that is shipped with the heat section. A plug-in harness is provided for quick connection to the cooling chassis and a receptacle for connection to the heat section. The control box is factory overlaid with a tough, polycarbonate membrane to preserve its appearance for many years. See Figure 4. Color-coded push buttons and large, raised function indicators improve readability for the visually impaired. Figure 4: Control Overlay Constant/Cycle Fan Switch A constant/cycle fan switch is provided in the Type K unit, allowing the fan to run continuously or cycle with the thermostat. This switch is located on the control box and is concealed behind the front panel to prevent unauthorized tampering. When the switch is placed in the cycle mode, the indoor fan will energize when there is a call for heating, cooling, or fan. Placed in the constant mode, the fan will run continuously. Constant fan offers better air circulation and improved fan filtration compared with the cycle option. Figure 5: Long Control Box Individual Room Conditioning The concept of individualized room conditioning began many years ago with the Type K conditioner. Over the years this design has become the benchmark for quality and reliability. Continual research and product improvement has allowed Daikin to remain the leader in the sectionalized unit market. Recent design changes have further enhanced the efficiency and durability of the Type K chassis. Many important features have been developed. Those features relevant to this design change are listed below. Fan Option A fan only function is provided to enable fan operation for improved circulation and increased air filtration. The dual speed fan is controlled by a unit mounted fan speed rocker switch for user convenience. Remote Control The Type K unit can be connected to a wall thermostat for remote control operation. A variety of thermostats are compatible with this unit including many programmable varieties. Multiple Unit Control Large conference rooms and hallways can be conditioned by many units using a single thermostat. One unit is designated as a control unit and up to seven units can be connected to the control unit for synchronized operation. Any unit can be designated as the control unit with only minor field wiring modifications to make the other units into the controlled units. Heat Section There are three types of heat sections available for the Type K units: hot water, steam, and electric resistance. Like the cooling chassis, these sections are built to last. There are many unique features of the Type K heating section that have contributed to its popularity. The heat section is independent of the cooling chassis. Unique features of the Type K heat section are listed below. Quiet Operation Large forward curved fans are used on the indoor side to provide efficient comfort conditioning with low sound levels. The blow-through design and heavy-gauge sheet metal provide a high degree of attenuation not found in draw-through designs. High Efficiency Motors High efficiency, low sound producing PSC motors are utilized by Type K units. All motors employ extended lube lines for periodic lubrication during scheduled maintenance. Page 6 of 28 Catalog

7 Design Features Factory Installed Valve Hot water and steam heat sections are furnished with a factory installed valve. Normally open, 2-way line voltage valves are supplied for hot water coils and normally closed 2-way line voltage valves are supplied on steam valves. Figure 6: Short Control Box (sizes shown) The discharge grille of the room cabinet is equipped with individual four-way adjustable steel grilles. This feature allows the owner to force the air in various directions to prevent stagnation. An extruded aluminum discharge grille is optional. This grille is available to further enhance the unit's appearance. The Type K room cabinet is factory furnished in a variety of depths to accommodate every wall thickness. The entire cabinet is powder coated with an epoxy Antique Ivory finish and comes complete with a handsome Oxford Brown reveal around the perimeter for accent. Figure 9: Cabinet Figure 7: Electric Heat Section Figure 10: Extruded Aluminum Discharge Grilles Figure 8: Hydronic Heat Section Filtration The filter is a permanent, cleanable wire mesh filter that is designed to provide superior dust collecting abilities. Room Cabinets The room cabinet is designed to complement any room decor. The heavy-gauge steel is coated with an attractive appliance grade powder paint which is then oven baked for durability. An adjustable kickplate is provided to accommodate various wall opening locations. The standard adjustment is +/-1". The room cabinet is designed to completely encompass the unit and conceal any piping or electrical connections from the room occupant. The front panel is removable for service access of filters, valves or electrical connections. Hidden latches are supplied to prevent unauthorized personnel from opening the front panel. Catalog Page 7 of 28

8 Design Features Wall Boxes The Type K wall box is made from heavy-gauge steel and coated with a tough epoxy powdered paint for corrosion protection. The wall box is designed to be placed into the wall during construction to assure a snug fit. The standard wall box can accommodate a wall depth of 13⅝'' without modifications. It can be easily adapted to deeper walls with minor factory modifications. Wall box/ sleeve extensions are available for field installation through your Daikin sales representative. The dimensions of the wall box have not changed since the unit was originally designed in Therefore, if the existing wall box is in good condition, the old chassis or heat section can be easily replaced without additional wall modifications. Consequently, the unit can be replaced to provide high efficiency operation with minimal disruption or downtime. Figure 11: Wall Box - Inside Figure 12: Wall Box - Outside View with Louver Louvers by others are acceptable as long as they meet factory specifications. They must have a minimum free area of % or a pressure drop not exceeding 0.05 in. w.g. at 300 fpm face velocity, and a blade design that will not cause recirculation of condenser air. Free area is defined by ASHRAE as the minimum area of the openings in an air inlet or outlet through which air can pass. Application of special louvers or building facade treatment that may affect normal operation of the unit, or restrict free air discharge of condenser airflow, should be referred to the Application Engineering Department for evaluation. A louver design that restricts the passage of condenser air or causes condenser air to be recirculated will dramatically alter the performance of the unit. Unit capacity and efficiency may be decreased and fan motor and compressor life may be shortened. If the louver does not meet the above outlined requirements or is only marginally acceptable, a drawing should be sent to the Incremental Application Engineering Department for evaluation. If acceptance still cannot be determined by the drawing, then a sample of the proposed louver should be sent to Daikin for testing and certification. The sample sent for testing must match the wall opening for the unit selected. Typical Louver Design Figure 15 shows some typical louver designs. The X dimension represents the narrowest dimension through which air must pass. The Y dimension represents the increment of rise between the blades. To calculate the percentages of free area, divide dimension X by dimension Y. Figure 14: Sample Calculation X Free Area % = Y x 100 Where: X = Y = Free Area % = 1.50 x 100 = 75% Figure 15: Louver Designs Outdoor Louvers The standard louver is a one-piece, extruded architectural aluminum type with a natural finish. Figure 13: Architectural Louver - Outside View Page 8 of 28 Catalog

9 Engineering Data Performance Data Unit Size Btuh Cooling Watts EER (Btuh/Watts) Airflow (CFM) High Speed/Low Speed 2/210 2/ /1 260/1 Ventilation CFM Volts 115V 208V 230V 265V 208V 230V 265V 208V 230V 265V 208V 230V 265V Electric Heaters L Heater M Heater Amps Watts Amps Watts Hydronic Heat (Btuh) Minimum Circuit Ampacity Time Delay Fuse, or if under 250V Type HACR Circuit Breaker S Heater Amps Watts Hot Water 15,500 15,500 15,500 15,500 Steam 19,200 19,200 19,200 19,200 L Heater M Heater S Heater Hydronic L Heater M Heater S Heater Hydronic Notes: Based on ASHRAE and ARI test conditions of 95 F DB/75 F WB outdoors, F DB/67 F WB inside. Includes fan motor. Based on 200 F EWT, 1 F LWT; 2 psig steam 65 F EAT. Tested and rated in accordance with AHRI Standards 310 and 3. Catalog Page 9 of 28

10 Engineering Data Cooling Capacities at Nonstandard Conditions Table 1: Size 007 O.D. Temp I.D. DB Temp. I.D. WB Temp. Total Capacity Btuh Sensible Capacity Btuh Total Watts Table 2: Size 009 O.D. Temp I.D. DB Temp. I.D. WB Temp. Total Capacity Btuh Sensible Capacity Btuh Total Watts Page 10 of 28 Catalog

11 Engineering Data Table 3: Size 012 Table 4: Size 014 O.D. Temp. I.D. DB Temp. I.D. WB Temp. Total Capacity Btuh Sensible Capacity Btuh Total Watts O.D. Temp. I.D. DB Temp. I.D. WB Temp. Total Capacity Btuh Sensible Capacity Btuh Total Watts Catalog Page 11 of 28

12 Engineering Data Heating Capacities at Nonstandard Conditions The hydronic coil can be used with either hot water or steam. To determine the correction factor at nonstandard conditions using hot water, use Figure 16. Follow the known flow rate to the corresponding EWT curve and read to the left to determine the heating correction factor. Apply this percentage to the standard ratings shown on page 9. Figure 16: Hot Water Heating Correction Factor Curve For conditions at temperatures other than 65ºF, determine the correction factor using Figure 18. From a known entering air temperature, follow up to the line and then go left to determine the correct percentage. Apply this percentage to Figure 16 (when using hot water) before plotting the heating correction factor. Figure 18: Heating Capacity Correction Factor Curve To determine the water pressure drop (WPD) at nonstandard flow rates, enter known gpm on Figure 19. Follow to conditioner line and read left for appropriate WPD. To find the WPD of the valve, repeat procedure. Add the WPD of the valve and the WPD of the conditioner to get the total. Figure 19: Water Pressure Drop Curve For ratings at nonstandard conditions using steam, refer to Figure 17. Follow the known steam pressure to the curve corresponding to the known entering air temperature. Read down to determine the correction factor. Multiply this number by the standard rating found on page 9 to determine the rating at nonstandard conditions. Figure 17: Steam Heating Correction Factors Btu Conversion Factor For Steam Rating Point 2 psig 65ºF Entering Air To use curve: 1. From known steam pressure and known air temperature, determine conversion factor. 2. Multiply published Btuh rating by conversion factor. Page 12 of 28 Catalog

13 Dimensional Data Overall Unit Dimensions Size 007 through 014 E D A C L B H M F G J K Table 5: Dimensions Unit Size A B C D E F G H J K L M in. 48 2½ Min. 7¼ Min. 36¼ 5¾ 24½ ½-5½ Adj. 1¾ 8 1 mm Min. 184 Min Adj Units With Electric Heat (Sizes 007 through 014) A H 8" (203mm) M Long Control Box E J Room Cabinet Room Cabinet Mounting Holes (4) B G F K Heat Section Power Cord Wall Box D Front View Notes: Guest room control, low voltage or master-slave wiring connection made at control box. Junction box with knockouts for 1/2'' (12mm) 3/4'' (19mm) conduit. See "Wall Box and Room Cabinet Dimensions" on page 16, and Table 6 for dimension B. Cooling Chassis Power Cord 1 2 '' (12mm) 1 4 '' (6mm) Side View A D E F G H J K M in mm Catalog Page 13 of 28

14 Dimensional Data Units With Hydronic Heat Short Control Box Note: The short control box is used with standard unit mounted manual changeover control, and unit mounted manual changeover with emergency standby (ESB) power supply. A H Short Control Box 8" (203mm) M J Hydronic Coil Room Cabinet Room Cabinet Mounting Holes (4) P B F E K L N Wall Box G Junction Box D Front View A D E F G H J K L M N P 1 2 '' (12mm) 1 4 '' (6mm) Side View Room Cabinet Removed in mm Notes: See page 15 for dimensions of factory installed valve and return piping stub. Junction box 7/8" (22mm) diameter knockouts for 1/2" (12mm) conduit. See "Wall Box and Room Cabinet Dimensions" on page 16, and Table 6 for dimension B. Long Control Box Note: The long control box is used with optional special controls such as Guest Room Control (GRC), Night Setback (NSB), and remote thermostats. Left-hand piping must be used with the long control box design. A E M J Hydronic Coil H Long Control Box Room Cabinet Room Cabinet Mounting Holes (4) 8" (203mm) B F K L Heat Chassis Power Cord Flexible Conduit Power Supply Cord Wall Box G D Front View Cool Chassis Power Cord Junction Box (By Others) 1 2'' (12mm) 1 4'' (6mm) Side View Room Cabinet Removed A D E F G H J K L M in mm Notes: See Figure 23 and Figure 27 on page 15 for dimensions of factory installed valve and return piping stub. See "Wall Box and Room Cabinet Dimensions" on page 16, and Table 6 for dimension B. Page 14 of 28 Catalog

15 Dimensional Data Suggested Piping Arrangements Hot Water Supply Figure 20: Detail A Hot Water Supply R.H., Retun L.H. C L Return Stub 2" (51mm) Steam Supply Figure 24: Detail B Steam supply R.H., return L.H. C L Return Stub C L 2 5 /8" (67mm) W Y S T V 2" (51mm) S T V 2 5 /8" (67mm) Figure 21: Detail C Hot water supply R.H., return R.H. C L U Return Stub C L 2" (51mm) Figure 25: Detail D Steam supply R.H., return R.H. C L U Return Stub C L 1" (25mm) T V W 1" (25mm) Figure 22: Detail E Hot water supply L.H., return R.H. 2" (51mm) C L Return Stub C L T V Y 2" (51mm) Figure 26: Detail F Steam supply L.H., return R.H. 2 5 /8" (67mm) C L Return Stub C L 2 5 /8" (67mm) V S U W 2" (51mm) V S U Y Figure 23: Detail G Hot water supply L.H., return L.H. 2" (51mm) C L Return Stub S C L Figure 27: Detail H Steam supply L.H., return L.H. 1" (25mm) CL Return Stub S C L 1" (25mm) W V U 2" (51mm) Y V U S T U V W Y in mm Notes: Available on size only. Available on size only. Available on size only. Available on size only. Catalog Page 15 of 28

16 Dimensional Data Wall Box and Room Cabinet Dimensions Figure 28: Wall Box and Room Cabinet Details Table 6: Wall Box and Room Cabinet Dimensions Dimension A Dimension C Cabinet Depth in. mm in. mm 0 to -1 0 to to +1 0 to to 2 25 to to 3 51 to to 4 76 to to to to to to to to to to to NOTICE Dimension B will vary by the thickness of the wall, the louver, the amount the louver is recessed into the wall (if any) and the amount the wall box extends into the room. The minimum B dimension is 2 1 2'' (64mm). The wall box can be factory furnished in increments between 2 1 2'' (64mm) and 10'' (254mm). Wall box extensions in 1'' (25mm) increments can also be provided to attach to the rear of the wall box. Note: Drawing not to scale. Table 7: Wall Box Dimensions Dimensions - inches Wall Box B Dimension Overall Length Dimensions - mm Wall Box B Dimension Overall Length Outdoor Louver Dimensions Figure 29: Unit Sizes 007 through 014 Extruded Architectural " (343mm) 36" (914mm) 1 1 8" (29 mm) Louver Frame *13 7 8" (352mm) " (410mm) *36 1 4" (921mm) " (978mm) 3 3 8" (86mm) *Note: Inside dimensions. External dimensions for wall opening are " x " (356mm x 929mm). Page 16 of 28 Catalog

17 Typical Wiring Diagrams Standard Chassis With Electric Heat & MCO Controls (Sizes ) Note: Refer to the schematic located on the unit. COOL SECTION CONTROL BOX HEAT SECTION TC1 Room Thermostat TC2 Night Setback Thermostat (NSB) TC3 Heat Fan Lockout TC4 Low Ambient Lockout VM Valve Motor WN Wire Nut R4 Relay, Guest Room Control (GRC) R5 Relay, Hot Water Valve R6 Relay, Control R7 Relay, Night Setback (NSB) S1 Control Switch S2 Fan Speed Switch S3 Fan Cycle Switch S4 Damper Switch T1 Transformer TB1 Terminal Block, Control Box TB2 Terminal Board (24V), Control Box TB3 Terminal Board, Heat Section TB4 Terminal Board, Cool Section TB6 Terminal Box C1 Capacitor, Indoor Fan C2 Capacitor, Outdoor Fan C3 Capacitor, Compressor GRC Guest Room Control HL High Limit HTR Heater MP Motor Protector NSP Night Setback Control P1 Plug, Control Box/Heat Section to Cool Section R1 Relay, Heat R2 Relay, Cool R3 Relay, Night Setback (NSB) Catalog Page 17 of 28 S1 Switch Contact Positions Unit Mounted Manual Changeover

18 Typical Wiring Diagrams Standard Chassis With Hot Water Heat & MCO Controls (Sizes ) Note: Refer to the schematic located on the unit. COOL SECTION HEAT SECTION CONTROL BOX S1 Switch Contact Positions Unit Mounted Manual Changeover C1 Capacitor, Indoor Fan C2 Capacitor, Outdoor Fan C3 Capacitor, Compressor GRC Guest Room Control HL High Limit HTR Heater MP Motor Protector NSP Night Setback Control P1 Plug, Control Box/Heat Section to Cool Section R1 Relay, Heat R2 Relay, Cool R3 Relay, Night Setback (NSB) R4 Relay, Guest Room Control (GRC) R5 Relay, Hot Water Valve R6 Relay, Control R7 Relay, Night Setback (NSB) S1 Control Switch S2 Fan Speed Switch S3 Fan Cycle Switch S4 Damper Switch T1 Transformer TB1 Terminal Block, Control Box TB2 Terminal Board (24V), Control Box TB3 Terminal Board, Heat Section TB4 Terminal Board, Cool Section TB6 Terminal Box TC1 Room Thermostat TC2 Night Setback Thermostat (NSB) TC3 Heat Fan Lockout TC4 Low Ambient Lockout VM Valve Motor WN Wire Nut Page 18 of 28 Catalog

19 Typical Wiring Diagrams Standard Chassis With Steam Heat & MCO Controls (Sizes ) Note: Refer to the schematic located on the unit. COOL SECTION HEAT SECTION CONTROL BOX TC1 Room Thermostat TC2 Night Setback Thermostat (NSB) TC3 Heat Fan Lockout TC4 Low Ambient Lockout VM Valve Motor WN Wire Nut R4 Relay, Guest Room Control (GRC) R5 Relay, Hot Water Valve R6 Relay, Control R7 Relay, Night Setback (NSB) S1 Control Switch S2 Fan Speed Switch S3 Fan Cycle Switch S4 Damper Switch T1 Transformer TB1 Terminal Block, Control Box TB2 Terminal Board (24V), Control Box TB3 Terminal Board, Heat Section TB4 Terminal Board, Cool Section TB6 Terminal Box C1 Capacitor, Indoor Fan C2 Capacitor, Outdoor Fan C3 Capacitor, Compressor GRC Guest Room Control HL High Limit HTR Heater MP Motor Protector NSP Night Setback Control P1 Plug, Control Box/Heat Section to Cool Section R1 Relay, Heat R2 Relay, Cool R3 Relay, Night Setback (NSB) S1 Switch Contact Positions Unit Mounted Manual Changeover Catalog 1302 / Page 19 of 32

20 Typical Wiring Diagrams Standard Chassis With Electric Heat & 24V Wall Stat (Sizes ) Note: Refer to the schematic located on the unit. COOL SECTION CONTROL BOX HEAT SECTION C1 Capacitor, Indoor Fan C2 Capacitor, Outdoor Fan C3 Capacitor, Compressor GRC Guest Room Control HL High Limit HTR Heater MP Motor Protector NSP Night Setback Control P1 Plug, Control Box/Heat Section to Cool Section R1 Relay, Heat R2 Relay, Cool R3 Relay, Night Setback (NSB) R4 Relay, Guest Room Control (GRC) R5 Relay, Hot Water Valve R6 Relay, Control R7 Relay, Night Setback (NSB) S2 Fan Speed Switch S3 Fan Cycle Switch S4 Damper Switch T1 Transformer TB1 Terminal Block, Control Box TB2 Terminal Board (24V), Control Box TB3 Terminal Board, Heat Section TB4 Terminal Board, Cool Section TB6 Terminal Box TC1 Room Thermostat TC2 Night Setback Thermostat (NSB) TC3 Heat Fan Lockout TC4 Low Ambient Lockout VM Valve Motor WN Wire Nut Catalog 1302 / Page 20 of 32

21 Typical Wiring Diagrams Standard Chassis With Hot Water Heat & 24V Wall Stat (Sizes ) Note: Refer to the schematic located on the unit. COOL SECTION CONTROL BOX HEAT SECTION TC1 Room Thermostat TC2 Night Setback Thermostat (NSB) TC3 Heat Fan Lockout TC4 Low Ambient Lockout VM Valve Motor WN Wire Nut R4 Relay, Guest Room Control (GRC) R5 Relay, Hot Water Valve R6 Relay, Control R7 Relay, Night Setback (NSB) S1 Control Switch S2 Fan Speed Switch S3 Fan Cycle Switch S4 Damper Switch T1 Transformer TB1 Terminal Block, Control Box TB2 Terminal Board (24V), Control Box TB3 Terminal Board, Heat Section TB4 Terminal Board, Cool Section TB6 Terminal Box C1 Capacitor, Indoor Fan C2 Capacitor, Outdoor Fan C3 Capacitor, Compressor GRC Guest Room Control HL High Limit HTR Heater MP Motor Protector NSP Night Setback Control P1 Plug, Control Box/Heat Section to Cool Section R1 Relay, Heat R2 Relay, Cool R3 Relay, Night Setback (NSB) Catalog 1302 / Page 21 of 32

22 Typical Wiring Diagrams Standard Chassis With Steam Heat & 24V Wall Stat (Sizes ) Note: Refer to the schematic located on the unit. Catalog 1302 / Page 22 of 32 R4 Relay, Guest Room Control (GRC) R5 Relay, Hot Water Valve R6 Relay, Control R7 Relay, Night Setback (NSB) S1 Control Switch S2 Fan Speed Switch S3 Fan Cycle Switch S4 Damper Switch T1 Transformer TB1 Terminal Block, Control Box TB2 Terminal Board (24V), Control Box TB3 Terminal Board, Heat Section TB4 Terminal Board, Cool Section TB6 Terminal Box TC1 Room Thermostat TC2 Night Setback Thermostat (NSB) TC3 Heat Fan Lockout TC4 Low Ambient Lockout VM Valve Motor WN Wire Nut COOL SECTION CONTROL BOX HEAT SECTION C1 Capacitor, Indoor Fan C2 Capacitor, Outdoor Fan C3 Capacitor, Compressor GRC Guest Room Control HL High Limit HTR Heater MP Motor Protector NSP Night Setback Control P1 Plug, Control Box/Heat Section to Cool Section R1 Relay, Heat R2 Relay, Cool R3 Relay, Night Setback (NSB)

23 Accessories and Options Remote Mounted Thermostats Type K units can be controlled by a remote mounted, low voltage wall thermostat. Several variations of low voltage wall thermostats are available. The most common types used are manual changeover and automatic changeover. Figure 30 and Figure 31 illustrate the typical wiring schematics for proper connection of the Type K series units to the wall thermostat. Figure 30: Manual Changeover (MCO) R N/A G Y W 24V Power 24V Common Fan Cool Heat MCO T' Stat Figure 31: Automatic Changeover (ACO) Thermostat (10551) Jumper R R C G Y1 W1 C R C A G W2 Y1 W1 Factory installed jumper Control Unit Terminal Board Master Unit Control When using remote mounted thermostats, it is often necessary to control more than one Type K unit from a single thermostat. Figure 32 illustrates schematically how a controlling and controlled unit(s) are connected to a single thermostat. Note that the jumper between terminals C and A of the control Figure 32: Multiple Unit Control with Each Available Thermostat Jumper R R C G Y1 W1 Jumper R R C G Y1 W1 Jumper C C R H R C G Y1 W1 Thermostat Choice (See Figure 32) R C Factory installed jumper A G W2 Y1 W1 Control Unit Terminal Board unit is removed. This takes the controlling unit's transformer out of the circuit allowing it to duplicate the operation of the controlling unit. The controlling unit's transformer handles 50 VA power draw. Each controlling unit has up to 5.6 VA power draw. Up to seven controlled units can be connected to the controlling unit without danger of overheating the main transformer, although it is unlikely this many controlled units will be connected to one controlling unit. CAUTION Be sure to check the amperage rating of the wall thermostat to prevent exceeding the maximum amperage of the thermostat contacts. NOTICE If more than 6 controlled units, control unit transformer must be changed and thermostat contact capability must be considered. R G Y W 24V 24V Fan Cool Heat Power Common (See Figure 31) R C A G W2 Y1 W1 Control Unit (single) Terminal Board Factory installed jumper R C A G W2 Y1 W1 Controlled Unit (1) Terminal Board Up to 6 controlled units (see notice) Remove this jumper on all controlled unit(s) Catalog Page 23 of 28

24 Energy Saving Options Guest Room Control (GRC) This additional control, widely used by hotel/motel operations, is provided for use on Type K equipment. GRC allows the owner to substantially reduce energy consumption by de-energizing the equipment in unoccupied spaces. The Incremental units are wired to a central location, usually the front desk, where they are controlled by a toggle switch in a control panel (supplied by others). The units remain de-energized until the room becomes occupied, at which time the clerk can energize the equipment from the front desk (see Figure 33). Night Setback Control (NSB) Additional savings can be achieved through use of the night setback control (NSB). NSB incorporates an additional unit mounted thermostat to maintain a minimum, predetermined room temperature. The temperature is set at the factory to 55ºF (13ºC). This setpoint is adjustable by the owner to activate anywhere between 45ºF and 55ºF (7ºC and 13ºC). If the room temperature drops below the owner selected minimum temperature, the heat cycle and indoor fan are energized until the night setback thermostat is satisfied. NSB overrides the unit control even if it is placed in the stop position or inadvertently left in the cool position. Outdoor Air Dampers Type K units are furnished with an automatic outdoor air damper as standard. The automatic damper is wired in parallel to the indoor fan safety. If the unit is placed in the cycle mode, the fan and damper cycle as the thermostat cycles. If the unit is placed in the constant mode, the fan runs continuously and the damper is always open. The automatic damper feature can be overridden during NSB if the unit is so equipped. This prevents cold air from entering the occupied space when the unit is simply bringing the room back to the night setback temperature. Since NSB is used when the room is unoccupied, there is no reason to introduce outside air during this cycle. Figure 33: Guest Room Control Low voltage transformer (by others) Switch #1 Occupied Conditioner #1 Switch #2 Unoccupied Occupied Switch #3 Unoccupied Occupied Conditioner #2 Unoccupied Conditioner #3 Central control panel (by others) Relay L1 L2 Page 24 of 28 Catalog

25 Engineering Guide Specifications General Furnish packaged incremental comfort conditioners of the sizes and capacities shown on the schedule and/or specifications. The units shall be located as shown on the drawings and each shall include a wall box, room cabinet, separate cooling chassis, heating section, separate control box, and outdoor louver. All units shall be ETL listed for safety. Units shall be tested and rated in accordance with ARI Standards 310 and 3. Units shall be Daikin Type K Model designated with prefixes PKES (cooling chassis) or PKHS (heating section) or equals. Units shall be designed to operate on (115) (208) (230) (265) volts, 60 Hz, single-phase power. The minimum energy efficiency ratio (EER) in Btu per hour per watt for each packaged incremental comfort conditioner must be 8.0 for all sizes. Cooling Chassis Cooling chassis shall be slide-in, plug-in with a self-contained, hermetically sealed refrigerant circuit. All chassis sheet metal parts shall be constructed of heavy-gauge steel. The chassis shall be insulated with a waterproof material to prevent sweating and reduce sound levels. The cooling chassis shall consist of the following components: Vibration isolated, permanent split capacitor, rotary-type compressor with built in thermal overload; rifled copper tubed evaporator (indoor) and condenser (outdoor) coils with high efficiency raised lance aluminum plate fins mechanically expanded to the tubes for maximum heat transfer and a capillary restrictor type refrigerant metering device supplemented with a constant pressure automatic expansion valve. Coils shall be factory tested at 600 psig. Condenser airflow system shall consist of a separate, single speed PSC motor with an aluminum blade centrifugal fan. The motor shall be totally enclosed and permanently lubricated with external oilers for prolonged life. The fan shall be forward curved and statically and dynamically balanced to provide for quiet and smooth operation. The cooling chassis shall also be furnished with a positive closing, automatic, motorized outdoor air damper that opens whenever the indoor fan is energized, except during night setback operation. A toggle switch shall be provided for manual override of the damper. During the cooling cycle, the compressor and both the outdoor/condenser and indoor/evaporator fan motors shall be energized. Condensation accumulated in the indoor/evaporator drain pan shall be drained into the outdoor section of the unit where it is to be completely removed by evaporation. Evaporation shall be accomplished by uniformly distributing the condensate over the condenser coil via airflow generated by the outdoor/condenser fan. Condensate shall not come in contact with fan or fan motor. Slinger rings and propeller fans are not an acceptable solution for condensate removal. Heating Section The heat section shall be separate from the cooling chassis and shall incorporate an indoor/evaporator fan assembly. This assembly shall consist of two centrifugal fans that are forward curved and constructed out of aluminum with steel hubs and directly connected to a two-speed motor. Fans shall be statically and dynamically balanced to provide for quiet and smooth operation. The indoor/evaporator fan motor shall be two speed, permanent split capacitor, totally enclosed and permanently lubricated with external oilers for prolonged life. Built-in overload protection shall come standard with the motor. (Electric Resistance Heat Only Models) During the heating cycle, only the indoor/evaporator fan motor and electric resistance heaters are energized. The outdoor/condenser fan motor and compressor shall not be energized. Heaters shall be open wire type with quick response and high limit cutout. Electric resistance heaters shall be sized to meet heating requirements as shown on the schedule and/or specifications. Electric resistance heaters must not be visible or accessible through the indoor discharge grill. An electrical junction box shall be furnished for connection to field supplied power source. Additionally, a disconnect plug shall be factory installed for quick connection to the control box. (Hydronic Heat Models) The heating coil shall be suitable for hot water or steam supply and have a factory furnished (normally open) (normally closed) 2-way control valve. During the heating cycle only the indoor/evaporator fan motor, the control valve and automatic fresh air damper shall be energized. The outdoor/condenser fan motor and compressor shall not be energized. The heating coil shall have copper tubes with aluminum fins mechanically bonded for maximum heat transfer. Return piping shall be 5 /8 " O.D. plain copper tube. Control Box The control box shall be a separate component with plug-in connections to the heating section and cooling chassis. For sizes up to 14,000 Btuh, a concealed switch shall be furnished to automatically cycle or provide constant operation of the indoor fans. When placed in Cycle mode, the indoor/evaporator fans shall be automatically controlled by the thermostat when the HEAT, COOL, or FAN modes are selected. When placed in Constant mode, the fan shall run continuously except when the STOP button is depressed. Unit sizes above 14,000 Btuh shall always be furnished with constant fan operation only. The control overlay must be designed for the visuallyimpaired by containing large, raised function indicators and color-coded selector buttons placed on a white polycarbonate membrane. Raised function indicators must conform to standards set by the National Federation of the Blind and comply with the federally mandated American Disabilities Act (ADA). Catalog Page 25 of 28

26 Engineering Guide Specifications Room Cabinet The room cabinet shall be made of heavy-gauge steel and coated with oven baked polyurethane powder paint for maximum protection. To accommodate various wall opening locations and floor irregularities, an adjustable kickplate shall be furnished with a standard adjustment of +/- 1". A removable front panel shall be supplied for service access of the filter, electrical connections, cooling chassis and heat section. Hidden latches shall be provided to prevent unauthorized personnel from removing the front panel. Indoor air discharge grilles shall be equipped with four-way positional [stamped steel] [extruded aluminum] covered with an oven baked epoxy powder paint for maximum protection. Filtration Filtration shall be accomplished using a permanent, cleanable aluminum wire mesh filter. Wall Box The wall box shall be constructed from 16-gauge steel and welded for strength and durability. Once assembled, the wall box shall be coated with an oven baked epoxy powder paint to assure maximum corrosion protection. Outside Air Louvers Outside air louvers shall be (stamped) (extruded architectural) anodized aluminum as shown on plans. Louver shall be (finished natural) (painted) as shown on the schedule. (Stamped louvers shall be heavy gauge anodized aluminum of no less than 16 gauge.) Special field fabricated louvers must be approved Page 26 of 28 Catalog

27 Catalog Page 27 of 28

28 Daikin Training and Development Now that you have made an investment in modern, efficient Daikin equipment, its care should be a high priority. For training information on all Daikin HVAC products, please visit us at and click on Training, or call and ask for the Training Department. Warranty All Daikin equipment is sold pursuant to its standard terms and conditions of sale, including Limited Product Warranty. Consult your local Daikin Representative for warranty details. Refer to Form Y. To find your local Daikin Representative, go to Aftermarket Services To find your local parts office, visit or call 0-37PARTS ( ). To find your local service office, visit or call This document contains the most current product information as of this printing. For the most up-to-date product information, please go to Products manufactured in an ISO certified facility Daikin Applied (0) IM D (10/13)

McQuay Type J Series Incremental Conditioner

McQuay Type J Series Incremental Conditioner Catalog 1330-5 McQuay Type J Series Incremental Conditioner Contents Model Nomenclature...2 Incremental Type J Application...3 Design Features... 4-6 Dimensional Data... 7-8 Electric Units...7 Hydronic

More information

Incremental Comfort Conditioners

Incremental Comfort Conditioners Style, comfort and energy efficiency...one room at a time. Incremental Comfort Conditioners Model PDNS Top-mounted Hydronic Heat Engineered for flexibility and performance PDNS Incremental Comfort Conditioners

More information

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C: McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C: 1355-4 Page 2 / Catalog 1355-4 (Rev. 5/99) The McQuay Suite II Incremental packaged terminal air conditioners

More information

EnerSaver Packaged Terminal Air Conditioner Catalog 1303 and Heat Pump with R-410A Refrigerant

EnerSaver Packaged Terminal Air Conditioner Catalog 1303 and Heat Pump with R-410A Refrigerant EnerSaver Packaged Terminal Air Conditioner Catalog 1303 and Heat Pump with R-410A Refrigerant Model PNES Air Conditioner with Electric or Hydronic Heat Model PNHS Heat Pump with Electric Heat Design Series

More information

Type K Incremental Packaged Terminal Air Conditioner

Type K Incremental Packaged Terminal Air Conditioner Installation & Maintenance Data IM 1068 Group: PTAC Part No.: 669729001 Date: March 2010 Type K Incremental Packaged Terminal Air Conditioner Incremental Room Conditioner with R-410A Refrigerant 2010 McQuay

More information

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017 Replacement Parts List No. 700028400 Revision A 07/207 Daikin McQuay Incremental PKEI, PKES, PKHS 07-09 Design 2 To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat

Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat Applied Packaged Terminal Air Conditioner with Catalog 1355-9 Top-Mounted Hydronic Heat 16" 42" Model PDAN Unit Sizes 007 017 R-410A Refrigerant Engineered for flexibility and performance Unit Features

More information

Catalog EnerSaver Packaged Terminal Air Conditioners and Heat Pumps

Catalog EnerSaver Packaged Terminal Air Conditioners and Heat Pumps Catalog 300-5 EnerSaver Packaged Terminal Air Conditioners and Heat Pumps Units are listed by the Canadian Standards Association Table of Contents Agency Approval...2 Nomenclature...3 System Features...

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

Product Specifications. Vertical Floor Consoles By First Co.

Product Specifications. Vertical Floor Consoles By First Co. NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series

More information

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS New Construction Model Model EGN Superior Sound Performance Operating and Transmission Loss (OITC) High Efficiency 42 x 16 Wall Sleeve Semi-Custom Options Modern

More information

ICE AIR LLC. Draw1 REV. - PERFORMANCE DATA 117/133 COOLING CAPACITY CORRECTION FACTORS HEATING CAPACITY CORRECTION FACTORS

ICE AIR LLC. Draw1 REV. - PERFORMANCE DATA 117/133 COOLING CAPACITY CORRECTION FACTORS HEATING CAPACITY CORRECTION FACTORS 0 ICE AIR LLC HARTFORD AVENUE, MOUNT VERNON, NY 10553 WEBSITE: http://www.ice-air.com TEL: (914) 668-4700; FAX: (914)668-5643 Draw1 REV. - 117/133 SENS HEAT RATIO, % TOTAL COOL CAP; % 120 110 COOLING CAPACITY

More information

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000

More information

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000 Replacement s List No. 5709900 Revision N 0/205 McQuay Incremental MQE 007, 009, 02, 05, 06 MQR 007, 009, 02, 05 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call -800-377-2787

More information

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS Modern features and controls Superior sound performance Smaller footprint Semi-custom options PROFILE Evergreen Products is your complete solution for Packaged

More information

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS New Construction Model Model EGN Superior Sound Performance Operating and Transmission Loss (OITC) High Efficiency 42 x 16 Wall Sleeve Semi-Custom Options Modern

More information

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017 Replacement s List 055208000 Revision E 08/207 McQuay Incremental MQS 007-05 Vintages A 02-05 Vintage B Last Manufactured: 993 To find your Daikin Applied parts distributor, call -800-377-2787 or visit

More information

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4) Replacement Parts List No. 700018800 Revision C 08/2012 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design D (4) To find your Daikin Applied parts distributor,

More information

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package

More information

SeasonMaker ThinLine Fan-coil Units

SeasonMaker ThinLine Fan-coil Units Catalog C: 720-12 SeasonMaker ThinLine Fan-coil Units Type TSH & TSC Horizontal Design TSS, TPF, TSF & TSB Vertical Design C L I S T E D Ratings Certified by the Air Conditioning & Refrigeration Institute

More information

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection Series PIN New Construction or Renovation Application Flexible Quiet Comfort Damage Protection ADIRONDACK AIRE New Construction or Renovation The Adirondack-Aire PIN Series zerozone chassis provides environment

More information

SeasonMaker ThinLine Fan-coil Units

SeasonMaker ThinLine Fan-coil Units Catalog C: 720-12 SeasonMaker ThinLine Fan-coil Units Type TSH & TSC Horizontal Design TSS, TPF, TSF & TSB Vertical Design C L I S T E D Ratings Certified by the Air Conditioning & Refrigeration Institute

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

McQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1)

McQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1) Replacement Parts List No. 110509900 Revision E 07/2016 McQuay Incremental PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1) To find your Daikin Applied

More information

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991 Replacement Parts List No. 055203500 Revision G 05/206 McQuay Climate Control Singer Incremental ES, RS, S 06, 09,, 4 Vintage B Last Manufactured: 99 To find your Daikin Applied parts distributor, call

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers Models RCS 025C through 135C 25 to 135 Tons R-22/R407C Refrigerant Catalog 221-1 Table of Contents Introduction.... 3 The Condensing

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

MAC-120HE-03 Air-Cooled Chiller

MAC-120HE-03 Air-Cooled Chiller MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

13 GEP A L P - 1 A

13 GEP A L P - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

Q-TEC QC-Series Chilled Water Air Conditioner

Q-TEC QC-Series Chilled Water Air Conditioner Cooling Capacities: 13,3 to 49,3 BTUH (Based on EWT, GPM & CFM) Q-TEC QC-Series Chilled Water Air Conditioner The Q-TEC Series self-contained packaged chilled water air conditioner is designed to be installed

More information

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection Series PIC New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection ADIRONDACK AIRE New Construction and Renovation; Replaces

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

Q-Tec TM QC-Series Chilled Water Air Conditioner

Q-Tec TM QC-Series Chilled Water Air Conditioner Q-Tec TM QC-Series Chilled Water Air Conditioner Cooling Capacities:, to, BTUH (Based on EWT, GPM and ) The Q-Tec Series self-contained packaged chilled water air conditioner is designed to be installed

More information

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers Catalog 221-1 Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers Model RCS 025C to 135C R-22/R-407C Refrigerant Contents Introduction............................... 3 The Condensing

More information

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994 Replacement Parts List No. 05708900 Revision C 06/205 McQuay Incremental Packaged Terminal Air Conditioner MQT 06-4 Vintage B Last Manufactured: 994 To find your Daikin Applied parts distributor, call

More information

Concealed Ducted Split Series R-407C MBH

Concealed Ducted Split Series R-407C MBH Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY

More information

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS 3HPP / rhp3 Rooftop Units 60HZ Bulletin No. 0634 October 04 Supersedes October 0 MODEL NUMBER IDENTIFICATION -PHASE MODELS Nominal SEER (3HPP Shown) Unit Type

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH MHWW NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool Hi-Wall Fan Coil MHWW- 24 - H -1 2-Pipe Heat/Cool Heat/Cool Voltage 1=

More information

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH MHWW NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool Hi-Wall Fan Coil MHWW- 09 - H -1 2-Pipe Heat/Cool Heat/Cool Voltage 1=

More information

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

Submittal Data Performance Data Electrical Data

Submittal Data Performance Data Electrical Data ERMS Series Submittal Data Submittal Data Unit Designation: Job name: Architect: Engineer: Contractor: Performance Data Revision: 07/01/11 Cooling Capacity: EER: Heating Capacity: COP: Ambient Air Temp:

More information

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 18,000

More information

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS AIR CONDITIONERS 13ACXN MERIT Series R-410A Bulletin No. 210831 January 2018 Supersedes Bulletin No. 210739 SEER up to 15.50 1.5 to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh

More information

FCC Fan-Coil Units High-Performance, Vertical

FCC Fan-Coil Units High-Performance, Vertical FCC Fan-Coil s High-Performance, Vertical Model FCC construction features Piping and supply-duct connections are from top of unit, eliminating the need for side or back access Right or left-hand configurations

More information

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT SECTION 23 81 00 DECENTRALIZED UNITARY HVAC EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes packaged roof top unit, unit controls, remote panel, roof mounting curb and base, maintenance service,

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil MHCFC4W-16-01 Chilled/Hot Water Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.1 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 48,000 BTUH Multiaqua

More information

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil MHCFC4W-04-01 Chilled/Hot Water Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 12,000 BTUH Multiaqua

More information

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil MHCFC4W-08-01 Chilled/Hot Water Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.1 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua

More information

Specifications and Performance

Specifications and Performance R35C/H Packaged Terminal Air Conditioner (PTAC) Packaged Terminal Heat Pump (PTHP) Straight Cooling Nominal Capacities 9,000 12,000 15,000 18,000 Btuh 2.6 3.5 4.4 5.3 kw Heat Pump Nominal Capacities 9,000

More information

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

PTAC/PTHP. Packaged Terminal Air Conditioners and Heat Pumps. Residential & Light Commercial HVAC. Features: Performance:

PTAC/PTHP. Packaged Terminal Air Conditioners and Heat Pumps. Residential & Light Commercial HVAC. Features: Performance: Residential & Light Commercial HVAC PTAC/PTHP Packaged Terminal Air Conditioners and Heat Pumps Fedders Packaged Terminal Air Conditioners are designed to fit all 16" H x 42" W wall sleeves. They are the

More information

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System PART 1 SYSTEM DESCRIPTION 1.1 The HVAC system is based on the CGC HYBRID Hydronic Heat Pump System. 1.2 The system will automatically

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

NEW! Digital Packaged Terminal Air Conditioners. Over 40 standard features! Distinct, audible sound improvements

NEW! Digital Packaged Terminal Air Conditioners. Over 40 standard features! Distinct, audible sound improvements Digital Packaged Terminal Air Conditioners Over 40 standard features! Distinct, audible sound improvements Quality design & components throughout Exceptional energy efficiency NEW! Digital Temperature

More information

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through tons, up to 7,800 BTUH Heating The SPXB-HW Series "Suite 0" is a compact, throughthe-wall single package vertical HVAC

More information

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION CONDITIONERS DRY CHARGE UNITS PRODUCT SPECIFICATIONS Bulletin No. 20636 May 204 Supersedes March 202.5 to 5 Tons MODEL NUMBER IDENTIFICATION L C S 3 DC - 036-230 - 2 Lennox Minor Revision Number Air Conditioner

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0

More information

Cabinet Unit Heaters Steam / Hot Water

Cabinet Unit Heaters Steam / Hot Water 11-160.4 February, 2005 Cabinet Unit Heaters Steam / Hot Water Model C MODEL IDENTIFICATION Table of Contents I. Model Identification... 3 Page Il. IIl. III. IV. Design Benefits A. Features and Benefits...

More information

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED

More information

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental TECAM S.A. Tecnología Ambiental R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz harmony 5PZA Direct Expansion Registration No.: SC 4696-1 Registration No.: CO-SC 4696-1 Air Conditioning Equipment Manufacturer

More information

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw

More information

HiLine Vertical Stacking Fan Coils. Type FHSS and FHSK. Catalog

HiLine Vertical Stacking Fan Coils. Type FHSS and FHSK. Catalog HiLine Vertical Stacking Fan Coils Type FHSS and FHSK Catalog 770-17 Table of Contents Introduction.... 3 Daikin Applied HiLine Fan-Coil Units...3 Nomenclature...3 Introduction.... 4 Low CFM design (300

More information

SKYPAK II Heating & Cooling Self Contained Packages

SKYPAK II Heating & Cooling Self Contained Packages SKYPAK II Heating & Cooling Self Contained Packages SKYPAK II gives you a complete airconditioning and heating system as an all-in-one package unit. Designed for conventional through-the-wall installation

More information

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ) Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper

More information

Catalog Applied Packaged Terminal Air Conditioner with Top-mounted Hydronic Heat

Catalog Applied Packaged Terminal Air Conditioner with Top-mounted Hydronic Heat Catalog 1355-6 Applied Packaged Terminal Air Conditioner with Top-mounted Hydronic Heat 16" x 42 " Model PDAC/PDHP Table of Contents Beyond Standard Expectations...3-5 Introduction... 3 The Hydronic Experts

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on all models All models utilize round copper tube, aluminum plate

More information

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons) ENGINEERING DATA HEAT PUMP OUTDOOR UNITS HP40 50HZ Capacity 6.2 to 16.3 (21 200 to 55 500 Btuh) Heating Capacity 6.4 to 16.1 (21 800 to 55 500 Btuh) Bulletin No. 490088 October 2004 Supersedes August 1999

More information

Specifications and Performance

Specifications and Performance R45C/H Packaged Terminal Air Conditioner (PTAC) Packaged Terminal Heat Pump (PTHP) Straight Cooling Nominal Capacities 9,000 12,000 15,000 18,000 Btuh The Right Fit for Comfort 2.6 3.5 4.4 5.3 kw Heat

More information

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Compact, Self-Contained unit that offer low installation cost plus dependable performance. 0 Compact, Self-Contained unit that offer low installation cost plus dependable performance. From carrier s excellence in engineering come a new, compact of single package horizontal and vertical water

More information

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons 560.20-TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase

More information

Large Capacity Fan Coil Units Catalog Belt-Drive and Direct-Drive Cabinet and Hideaway Models

Large Capacity Fan Coil Units Catalog Belt-Drive and Direct-Drive Cabinet and Hideaway Models Large Capacity Fan Coil Units Catalog 735-12 Belt-Drive and Direct-Drive Cabinet and Hideaway Models Table of Contents Agency Listing and Nomenclature... 3 Overview....................................

More information

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons Product Data OMNIZONE 50BRN,BZN006-024 Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems 5 to 20 Nominal Tons The 50BRN,BZN water-cooled and remote air-cooled indoor, self-contained units

More information

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts GTIP60 ISO GT Series, Inch Pounds 60 Hz GT010070 (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts Rev: 903 Rev 1 Revisions: 31103 Changed HZ dwg to field convertible 5902 changed Unit

More information

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

CATALOG. SKYPAK Self-Contained Heating/Cooling Units CATALOG SKYPAK Self-Contained Heating/Cooling Units FORM SK145.00-EG6 (1211) TABLE OF CONTENTS SKYPAK Self-Contained Heating/Cooling Units Introduction...3 Product Overview...3 Nomenclature...4 SKYPAK

More information

PTAC Air Conditioners 11.7 EER / 3.4 COP. and Heat Pumps

PTAC Air Conditioners 11.7 EER / 3.4 COP. and Heat Pumps PTAC Air Conditioners and Heat Pumps Product Specifications 11.7 EER / 3.4 COP Product Features Quiet operation: STC of 28 Assembled in the USA for 30 years Increased dehumidification capacity 100% run-tested

More information

Catalog C: McQuay Horizontal Concealed Fan Coil Unit

Catalog C: McQuay Horizontal Concealed Fan Coil Unit Catalog C: 700-1 McQuay Horizontal Concealed Fan Coil Unit Model THC Sizes 200 Through 1200 CFM McQuay THC Horizontal Concealed Fan Coil Nomenclature F THC 1 H02 Fan-coil Type of Unit THC = Horizontal

More information

CWA4 Chilled & Hot Water Fan Coil

CWA4 Chilled & Hot Water Fan Coil CWA4 Chilled & Hot Water Fan Coil 4-Pipe Heat & Cool Fan Coil 24,000-60,000 BTUH 259 CWA4 NOMENCLATURE BREAKDOWN 4-Pipe Heat & Cool Multiposition Fan Coil Nominal BTUH 24=24,000 36=36,000 48=48,000 60=60,000

More information

BUILD YOUR REPUTATION ON OURS. Universal Modular Hi-Rise Series FAN COIL TECHNICAL CATALOG

BUILD YOUR REPUTATION ON OURS. Universal Modular Hi-Rise Series FAN COIL TECHNICAL CATALOG BUILD YOUR REPUTATION ON OURS Universal Modular Hi-Rise Series FAN COIL TECHNICAL CATALOG TABLE OF CONTENTS 2 Table of Contents 3 Universal Modular Hi-Rise Family 4 Features and benefits 5 Product Application

More information

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE NOW AVAILABLE WITH AUTOSPEED V CONTROL Product Specifications MB Series MBE Series W Series Vertical / Horizontal Direct Drive Hydronic Fan Coils 00 0 CFM NEW OPTION AVAILABLE: AUTOSPEED V CONTROL PACKAGE

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water

More information

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified Shelf Units 2, 3, and 4 ton R-407C ISO 9001 Certified the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision cooling system was developed by data processing

More information