1 VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG Spring 2017 Edition

2 BRYANT VRF ADVANTAGES IT TAKES an Efficient Solution...1 What is Variable Refrigerant Flow (VRF)...1 Simultaneous Heating & Cooling...1 Bryant VRF Scroll Compressor...3 High Performance Heat Exchanger Advanced Silent Technology with Fan Blade Design...3 Hinged and Control Design...4 Enhanced Defrost Control...4 High Efficiency High Heating Performance...5 VRF Installation Made Simple...6 Heat Recovery Benefits...8 Heat Pump Benefits...9 Single-phase Heat Pump Benefits...11 VRF OUTDOOR UNITS Overview Heat Recovery (3-phase) Multi-port Distribution Controller (MDC)...17 Heat Pump (Single-phase)...18 Heat Pump (3-phase)...19 VRF INDOOR UNIT Overview Way Cassette...26 Compact 4-Way Cassette...27 High Wall...28 Underceiling / Floor Console (Exposed)...29 Floor Console Recessed...30 Low Static Duct Medium Static Duct...32 High Static Duct...33 Vertical AHU...34 Outside Air...35 CONTROLS Individual Controls...36 Central Controls Building Automation...40

3 Bryant VRF Advantages IT TAKES an efficient solution You know what your building needs. Zoned comfort, better air quality, energy efficiency, design flexibility and long-term savings. Nothing delivers them all like a Bryant Variable Refrigerant Flow (VRF) system. We utilize a 2-pipe system for both heat pump and heat recovery. Through it, you can power up to 64 independent indoor units, providing precise, energy-efficient comfort control on a zone-by-zone basis. You can cool one room while heating the other or simply provide comfort to only the zones that are in use. WHAT IS VARIABLE REFRIGERANT FLOW (VRF) Bryant VRF systems provide precise, highly efficient comfort control. The name says it all: Variable Refrigerant Flow moves refrigerant to the specific zone that needs to be heated or cooled. It s the ultimate flexibility in HVAC: the refrigerant s flow can vary from location to location, delivering just what each zone needs. No more. No less. SIMULTANEOUS HEATING & COOLING A simplified 2-pipe design provides heat recovery and flexible refrigerant flow, Bryant VRF makes it possible to heat and cool different zones on a single refrigerant piping system at the same time. This also helps increase efficiency by capturing what would have been wasted energy from one space and returning it to the other as useful energy. 1

4 Bryant VRF Advantages COMPRESSOR Bryant rotates the operating sequence of the outdoor units and individual compressors. By spreading the operating hours evenly, occupants can enjoy balanced, consistent comfort. Inverter-driven compressors eliminate rush currents and on/off power surges as the system adjusts to demands. They also reduce the risk of compressor failure, more common in standard non-inverter systems. Should there be a failure, the outdoor unit provides greater backup capability, allowing the system to continue to operate and maintain comfort while the faulty compressor is isolated, repaired or addressed. ENERGY EFFICIENT You can t build today without making energy efficiency part of the equation. Our VRF systems improve climate control and minimize energy loss by heating and cooling different rooms at the same time. They circulate the minimum amount of refrigerant necessary to satisfy the building load and each individual zone while capturing what would have been wasted energy from one space and returning it to the other as useful energy. Coupled with that, outdoor units employ one or more Inverter-driven compressors, and each operating sequence is rotated to balance operating hours and load distribution. This means that the system operates at it s most efficient range more often, providing reduced energy consumption, and a more reliable system. AN EASIER SIMPLER INSTALLATION Our VRF systems require very little. There s no need for distribution fans, water pumps and large hydronic pipes or space-consuming maintenance rooms or service shafts; making them easy to install, while freeing up valuable space in the building. If you re working with a Bryant VRF specialist or become one yourself, you ll find the system is easy to control. The entire system can be run from a central location. MORE OPTIONS FOR MORE FLEXIBILITY Every building has different needs, so Bryant gives you a variety of choices. Our VRF products include a smaller equipment footprint, piping lengths up to 3280 ft. and a variety of ducted and ductless indoor unit options. It s a combination that delivers the utmost in design flexibility. Whether it s a commercial or large residential application, a single- or multi-floor building, a new build or a retrofit, you ll have all the options you need. 2

5 Bryant VRF Advantages BRYANT VRF SCROLL COMPRESSOR Bryant VRF Inverter-driven compressors can precisely match the building s cooling and heating demands, mostly operating within the most efficient frequency range, 50 to 80 Hz. With the compressors operating together, there s an increase in long-term durability. ASYMMETRIC SCROLL WRAP SYMMETRIC SCROLL WRAP HIGH PERFORMANCE HEAT EXCHANGER The advanced heat exchanger design enlarges the heat-exchange area, decreasing the air resistance while the hydrophilic fins and inner-threaded copper pipes optimize heat exchange efficiency. ADVANCED SILENT TECHNOLOGY WITH FAN BLADE DESIGN The unique 3 and 4 blade fan design decrease the running noise and lowers down airflow resistance and vibration. Paired with the DC Inverter compressor, the condenser is extremely quiet with operation as low as 58.4 db(a). 3

6 Bryant VRF Advantages HINGED ELECTRICAL AND CONTROL DESIGN Max. 150 o The electric control box can be rotated by a maximum of 150 degrees to make it much easier to dismount and more convenient for pipeline inspection or servicing. ENHANCED DEFROST CONTROL Intelligent defrosting Heating capacity t min Δt Usual defrosting Time The enhanced defrost control can adjust the defrosting cycle time based on system operating environments to reduce the time the system spends in defrost improving overall heating performance. By feeding hot gas through the bottom row of the outdoor coil we have eliminated the need for basepan heater accessories; improving system reliability. 4

7 Bryant VRF Advantages HIGH EFFICIENCY Bryant VRF achieves high efficiency in cooling and heating by utilizing all DC Inverter compressors, all DC fan motors and high-efficiency heat exchangers. The cooling IEER is 24.7, and heating SCHE BRYANT VRF HR WITH NON-DUCTED INDOOR UNITS UNDER AHRI RATING Ton 8 Ton 10 Ton 12 Ton 14 Ton 16 Ton 18 Ton 20 Ton 22 Ton 24 Ton 26 Ton 28 Ton SCHE IEER HIGH HEATING PERFORMANCE The Bryant VRF system provides heating down to -13 F with up to 70% of the rated heating capacity. This is just one more way we deliver comfort solutions for any indoor space, anytime of the year. 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% UP TO 98% OF HEATING CAPACITY AT 5O F 0 6 Ton 8 Ton 10 Ton 12 Ton 14 Ton 16 Ton 18 Ton 20 Ton 22 Ton 24 Ton 26 Ton 28 Ton 5

8 Bryant VRF Advantages VRF INSTALLATION MADE SIMPLE Bryant VRF was designed with the installer in mind, from the reduced piping connections to the control wiring method to startup and much more. Reduce Piping Connections Two-pipe heat recovery system with innovative multi-port distribution control (MDC) provides simultaneous cooling and heating while reducing refrigerant pipe connections by reducing the number of joints between the outdoor unit and MDC. The centrally located MDC allows for the use of soft copper line sets making installation simpler and faster. = 2 Connections Single Chassis Design (Heat Recovery Only) The single chassis design reduces the footprint of the outdoor unit. It reduces electrical connections by providing a single point power connection. And, thanks to a non-modular design that eliminates the need to twin outdoor units together in the field, it reduces the amount of piping work that has to be done on site. Controls Quick Connects All indoor units and MDCs are provided with a quick connect controls system. This allows for the use of accessory wire with preinstalled connectors or field-provided wiring with use of the included terminal accessory. This makes controls wiring faster and helps to reduce mis-wiring during installation. 6

9 Bryant VRF Advantages Controls Wiring Method/Design The controls wiring method more closely follows the piping arrangement. Heat pump systems use a daisy chain control wire configuration, while heat recovery systems use a hub and spoke design to wire from the outdoor unit to the MDC and then from the MDC to each indoor unit. By allowing the control wire to follow the piping design, installation becomes more intuitive for the contractor. Controls Wiring System Setup There s no need to access tight spaces above a ceiling to adjust rotary dials or dip switches in order to adjust or set functions on indoor units. Instead, all functions can be set up from a handheld Wireless Remote Controller or Wired Remote Controller. All of the functions are written in an easy-to-understand format, which saves time on system setup and start up. Our single-heat recovery system means a single-point electrical connection. This makes servicing the unit easier as you only have one disconnect to switch off and lock out. You ll also find tremendous savings when you compare triple-module units vs. a single-module unit for the same tonnage. Bryant VRF system footprint Conpetitor s VRF system footprint square feet square feet Smaller Footprint Bryant VRF systems provide several installation advantages by eliminating the need to install large distribution fans, water pumps and large pipes. What s more, they don t require dedicated maintenance rooms or service shafts, freeing up valuable real estate space in the building. The Bryant VRF heat recovery 20 ton system is up to 40% smaller than other VRF outdoor units in the marketplace. 7

10 Bryant VRF Advantages HEAT RECOVERY Bryant VRF heat recovery utilizes a 2-pipe system that allows for simultaneous heating and cooling. Multi-Port Distribution Controller The heat recovery system uses an outdoor multi-port distribution controller (MDC) with options from 6 to 16 ports, which acts as a central location allowing better refrigerant distribution to all indoor units. This controller can connect up to 32 different indoor units, and configuration typically takes less piping and connections. The main MDC can connect up to two sub MDC controllers allowing for up to 64 indoor units to be connected to a system. Operating Ranges The operating ranges for Bryant heat recovery systems provide heating down to -13 degrees with cooling up to 125 degrees Fahrenheit. -5 Cooling Mode Heating Mode 64 8

11 Bryant VRF Advantages Piping Length And Height Difference The Bryant VRF heat recovery system includes the multi-port distribution controller (MDC) that can be used as main or sub for greater piping flexibility. The main multi-port distribution controller can connect up to two sub multi-port distribution controllers to provide longer piping runs. The combination of a smaller equipment footprint and longer piping lengths, delivers up to 2,642 feet, making it easier for design. Heat Recovery C D E A Total Length 2642 ft* B Height between IDU-IDU 98 ft C Height between ODU-IDU - outdoor unit above - outdoor unit below 164 ft 131 ft B F D Distance between ODU-MDC 360 ft E Height between MDC-IDU 49 ft F Farthest equivalent length 541 ft A* : Total piping length for 20 ton unit Total piping length for 18 ton = 2476 ft Total piping length for 6 ~ 16 ton = 1968 ft HEAT PUMP When it comes to greater system efficiency and reliability, Bryant delivers. Our VRF heat pumps provide variable speed technology with multiple Inverter compressors ranging from 12 tons, single module, up to 36 tons, modular systems, that connect up to 64 multiplestyle indoor units. With increased sizes, Bryant VRF provides the flexibility to meet the needs to any building design. 9

12 Bryant VRF Advantages Operating Ranges The operating ranges for Bryant VRF heat pump systems provide heating down to -5 degrees with cooling up to 125 degrees Fahrenheit. 5 Cooling Mode Heating Mode 64 Piping Length And Height Difference If you need design flexibility, know that Bryant VRF gives you plenty. Our total piping length for heat pumps are up to 3,280 feet with up to 164 feet from the outdoor to the indoor unit, making it easier to design floors with lots of small rooms or to change the design later as needed. Plus, Bryant VRF heat pumps offer the most versatile piping designs from ground level up to the roof, depending on the design. Don t worry about consistent comfort. Y-shaped branching joints on the gas pipes between outdoor units ensure that refrigerant flow is equalized to each branch for enhanced system reliability. Heat Pump A B C A Total Length 3280 ft B Height between IDU-IDU 98 ft C Farthest pipe from 1 st branch 295 ft D E D Height between ODU-IDU - outdoor unit above - outdoor unit below 164 ft 131 ft E Farthest equivalent length 738 ft 10

13 Bryant VRF Advantages SINGLE-PHASE If you have a space that is too small for a standard VRF system, yet too large for residential ductless, our Single-phase VRF heat pump system is the perfect answer. It delivers the efficiency, flexibility and control of VRF but in a smaller capacity package and lower power requirement. With Bryant VRF, you can also integrate a Single-phase with a 3-phase heat pump and heat recovery to create one VRF system without additional controls. Operating Ranges The operating ranges for Bryant Single-phase VRF heat pump system provides heating down to -13 degrees with cooling up to 118 degrees Fahrenheit. 5 Cooling Mode Heating Mode 64 Piping Length And Height Difference Heat Pump A B C A Total Length 492 ft B Height between IDU-IDU 49 ft C Farthest pipe from 1 st branch 131 ft D E D Height between ODU-IDU - outdoor unit above - outdoor unit below 164 ft 131 ft E Farthest equivalent length 321 ft 11

14 VRF Outdoor Unit Overview Tonnage Heat Recovery Heat Pump Single-Phase Heat Pump Three-Phase Combo 1 Module 1 Module

15 BRYANT VRF OUTDOOR 38VMR Heat Recovery OUTDOOR UNIT 208/230V-3-60 Single module Outdoor unit model name 38VMA072RDS5-1 38VMA096RDS5-1 38VMA120RDS5-1 Nominal tons Ton Cooling capacity (*1) Nominal kbtu/h (with non-ducted indoor units/ducted) Rated kbtu/h Heating capacity (*1) Nominal kbtu/h (with non-ducted indoor units/ducted) Rated kbtu/h Power supply (*2) 208/230V, 3Phase, 60Hz With non-ducted Power consumption kw indoor units Cooling IEER (Integrated Energy Efficiency Btu/W Ratio) characteristics Power consumption kw (Nominal) (*1) Heating SCHE (Simultaneous Cooling & Btu/W Heating Efficiency) Power supply (*2) 208/230V, 3Phase, 60Hz With ducted Power consumption kw indoor units Cooling IEER (Integrated Energy Efficiency Btu/W Ratio) characteristics Power consumption kw (Nominal) (*1) Heating SCHE (Simultaneous Cooling & Btu/W Heating Efficiency) Height in 64-3/8 External Width in 52-3/4 dimensions Depth in 31-1/8 Total weight Unit lb 672 Compressor Type Hermetic Scroll Compressor (Inverter-Driven)/ 1 Fan unit Air volume cfm 6,900 7,600 8,100 Refrigerant (*3) (Charged refrigerant amount) lb MCA (*4) A Unit specifications Recommended fuse size A Refrigerant piping Connecting Gas side (main pipe) (brazing) in 3/4 7/8 1-1/8 port diameter Liquid side (main pipe) (brazing) in 5/8 3/4 3/4 Operation temperature range Cooling F DB 5 to 125 Heating F WB 13 to 64 Maximum external static pressure in WG 0.24 Maximum number of connected indoor units Maximum capacity of combined indoor units 50% to 150% Sound pressure level cooling/heating (*5) db(a) (*1) Rated conditions. Cooling: Indoor 80 F Dry Bulb/67 F Wet Bulb, Outdoor 95 F Dry Bulb. Heating: Indoor 70 F Dry Bulb, Outdoor 47 F Dry Bulb/43 F Wet Bulb. (*2) The source voltage must not fluctuate more than ±10% (*3) The amount does not consider extra piping length. Refrigerant must be added on site in accordance with the actual piping length. (*4) Select wire size based on larger value of MCA: Miminum Circuit Amps (Minimum Circuit Amps required for power supply design) (*5) These values, measured in anechoic chamber, at a point 3.3 ft (1 m) in front of the Unit at a height of 4.6 ft (1.4m). 13

16 38VMR Heat Recovery BRYANT VRF OUTDOOR OUTDOOR UNIT 208/230V-3-60 Single module Outdoor unit model name 38VMA144RDS5-1 38VMA168DS5-1 38VMA192DS5-1 38VMA216DS5-1 38VMA240DS5-1 Nominal tons Ton Cooling capacity (*1) Nominal kbtu/h (with non-ducted indoor units/ducted) Rated kbtu/h Heating capacity (*1) Nominal kbtu/h (with non-ducted indoor units/ducted) Rated kbtu/h Power supply (*2) 208/230V, 3Phase, 60Hz Power consumption kw With non-ducted IEER (Integrated indoor units Cooling Energy Efficiency Btu/W characteristics (Nominal) (*1) Heating Ratio) Power consumption kw SCHE (Simultaneous Cooling & Heating Btu/W Efficiency) Power supply (*2) 208/230V, 3Phase, 60Hz Power consumption kw With ducted IEER (Integrated indoor units Cooling Energy Efficiency Btu/W Ratio) characteristics Power consumption kw (Nominal) (*1) SCHE (Simultaneous Heating Cooling & Heating Btu/W Efficiency) Height in 64-3/8 External Width in 78-3/8 Dimensions Depth in 31-1/8 Total weight Unit lb 1137 Compressor Type/Qty Hermetic Scroll Compressor (Inverter-Driven)/ 2 Fan unit Air volume W 10,100 10,100 11,300 12,300 12,300 Refrigerant (*3) (Charged refrigerant amount) lb specifications Refrigerant piping Unit Connecting port diameter Operation temperature range MCA (*4) A Recommended fuse size A Gas side (main pipe) (brazing) in 1-1/8 1-1/8 1-1/8 1-1/8 1-3/8 Liquid side (main pipe) (brazing) in 7/8 7/8 7/8 1-1/8 1-1/8 Cooling F DB 5 to 125 Heating F WB 13 to 64 Maximum external static pressure in WG 0.24 Max Maximum number of connected indoor units Maximum capacity of combined indoor units 50% to 150% Sound pressure level cooling/heating (*5) db(a)

17 BRYANT VRF OUTDOOR 38VMR Heat Recovery OUTDOOR UNIT 460V-3-60 Single module Outdoor unit model name 38VMA072RDS6-1 38VMA096RDS6-1 38VMA120RDS6-1 Nominal tons Ton Cooling capacity (*1) Nominal kbtu/h (with non-ducted indoor units/ducted) Rated kbtu/h Heating capacity (*1) Nominal kbtu/h (with non-ducted indoor units/ducted) Rated kbtu/h Power supply (*2) 460V, 3Phase, 60Hz With non-ducted Power consumption kw indoor units Cooling IEER (Integrated Energy Efficiency Btu/W Ratio) characteristics Power consumption kw (Nominal) (*1) Heating SCHE (Simultaneous Cooling & Btu/W Heating Efficiency) Power supply (*2) 460V, 3Phase, 60Hz With ducted Power consumption kw indoor units Cooling IEER (Integrated Energy Efficiency Btu/W Ratio) characteristics Power consumption kw (Nominal) (*1) Heating SCHE (Simultaneous Cooling & Btu/W Heating Efficiency) Height in 64-3/8 External Width in 52-3/4 dimensions Depth in 31-1/8 Total weight Unit lb 672 Compressor Type/Qty Hermetic Scroll Compressor (Inverter-Driven)/ 1 Fan unit Air volume cfm 6,900 7,600 8,100 Refrigerant (*3) (Charged refrigerant amount) lb MCA (*4) A Unit specifications Recommended fuse size A Refrigerant Connecting Gas side (main pipe) (brazing) in 3/4 7/8 1-1/8 piping port diameter Liquid side (main pipe) (brazing) in 5/8 3/4 3/4 Operation temperature range Cooling F DB 5 to 125 Heating F WB 13 to 64 Maximum external static pressure in WG 0.24 Maximum number of connected indoor units Maximum capacity of combined indoor units 50% to 150% Sound pressure level cooling/heating (*5) db(a) (*1) Rated conditions. Cooling: Indoor 80 F Dry Bulb/67 F Wet Bulb, Outdoor 95 F Dry Bulb. Heating: Indoor 70 F Dry Bulb, Outdoor 47 F Dry Bulb/43 F Wet Bulb. (*2) The source voltage must not fluctuate more than ±10% (*3) The amount does not consider extra piping length. Refrigerant must be added on site in accordance with the actual piping length. (*4) Select wire size based on the larger value of MCA MCA: Minimum Circuit Amps (Minimum Circuit Amps required for power supply design) (*5) These values, measured in anechoic chamber, at a point 3.3 ft (1 m) in front of the Unit at a height of 4.6 ft (1.4m). 15

18 38VMR Heat Recovery BRYANT VRF OUTDOOR OUTDOOR UNIT 460V-3-60 Single module Outdoor unit model name 38VMA144RDS6-1 38VMA168DS6-1 38VMA192DS6-1 38VMA216DS6-1 38VMA240DS6-1 Nominal tons Ton Cooling capacity (*1) (with non-ducted indoor units/ducted) Heating capacity (*1) (with non-ducted indoor units/ducted) With non-ducted indoor units characteristics (Nominal) (*1) With ducted indoor units characteristics (Nominal) (*1) External Dimensions Nominal kbtu/h Rated kbtu/h Nominal kbtu/h Rated kbtu/h Power supply (*2) 460V, 3Phase, 60Hz Power consumption kw Cooling IEER (Integrated Energy Efficiency Ratio) Btu/W Power consumption kw Heating SCHE (Simultaneous Cooling & Heating Btu/W Efficiency) Power supply (*2) 460V, 3Phase, 60Hz Power consumption kw Cooling IEER (Integrated Energy Efficiency Ratio) Btu/W Power consumption kw Heating SCHE (Simultaneous Cooling & Heating Btu/W Efficiency) Height in 64-3/8 Width in 78-3/8 Depth in 31-1/8 Total weight Unit lb 1,137 Compressor Type/Qty Hermetic Scroll Compressor (Inverter-Driven)/ 2 Fan unit Air volume W 10,100 10,100 11,300 12,300 12,300 Refrigerant (*3) (Charged refrigerant amount) lb specifications Refrigerant piping Unit Connecting port diameter Operation temperature range MCA (*4) A Recommended fuse size A Gas side (main pipe) (brazing) in 1-1/8 1-1/8 1-1/8 1-1/8 1-3/8 Liquid side (main pipe) (brazing) in 7/8 7/8 7/8 1-1/8 1-1/8 Cooling F DB 5 to 125 Heating F WB 13 to 64 Maximum external static pressure in WG 0.24 Max Maximum number of connected indoor units Maximum capacity of combined indoor units 50% to 150% Sound pressure level cooling/heating (*5) db(a)

19 BRYANT VRF OUTDOOR 40VMD Multiport Distribution Controller (MDC) The Bryant VRF multi-port distribution controller (MDC) allows you to connect from 6 to 16 indoor units based on number of ports. The main multiport distribution controller can connect up to two sub multi-port distribution controllers VMD Main 40VMD006M VMD006M VMD006M VMD006M---3 Power supply (V-Ph-Hz) 208/ Number of ports Unit dimensions, 37 x 12-3/4 x 22-5/8 46-1/2 x 12-3/4"x 22-5/8 Unit Packing dimensions, 44-1/2 x 18 x 33-1/8 53-7/8 x 18 x 33-1/8 Net/gross weight (lb) 132/ / / /269 Design Pressure, High/Low (psig) 580 / 320 Power wiring Sized Per NEC and Local Codes Based on Nameplate Data Connecting wiring Signal wiring 2-Core Stranded Shielded Twisted Pair Cable 18AWG-16AWG Condensate Pipe Diameter, OD (in.) 1 MCA (A) Unit model number 40VMD006S VMD008S VMD010S VMD016S---3 Power supply (V-Ph-Hz) 208/ Number of ports Unit dimensions, 37 x 12-3/4 x 22-5/8 46-1/2 x 12-3/4 x 22-5/8 Unit Packing dimensions, 44-1/2 x 18 x 33-1/8 53-7/8 x 18 x 33-1/8 Net/gross weight (lb) 126/ / / /262 Design Pressure, High/Low (psig) 580 / 320 Power wiring Sized Per NEC and Local Codes Based on Nameplate Data Connecting wiring Signal wiring 2-Core Stranded Shielded Twisted Pair Cable 18AWG-16AWG Condensate Pipe Diameter, OD (in.) 1 MCA (A)

20 38VMH Single-phase Heat Pump BRYANT VRF OUTDOOR OUTDOOR UNIT 208/ Outdoor unit model name 38VMA036HDS3-1 38VMA048HDS3-1 38VMA060HDS3-1 Nominal tons Ton Cooling capacity (*1) (with non-ducted indoor units/ducted) Heating capacity (*1) (with non-ducted indoor units/ducted) With non-ducted indoor units characteristics (Nominal) (*1) With non-ducted indoor units characteristics (Nominal) (*1) External dimensions Power supply (*2) Cooling Heating Power supply (*2) Cooling Heating Nominal kbtu/h Rated kbtu/h Nominal kbtu/h Rated kbtu/h /230V, 1-Phase, 60Hz Power consumption kw SEER (Seasonal Energy Efficiency Ratio) Btu/W Power consumption kw HSPF (Heating Seasonal Performance Factor) Btu/W /230V, 1-Phase, 60Hz Power consumption kw SEER (Seasonal Energy Efficiency Ratio) Btu/W Power consumption kw HSPF (Heating Seasonal Performance Factor) Btu/W Height in 52-1/4 Width in 35-1/2 Depth in 15-3/4 Total weight Unit lb 220 Compressor Type / Qty Hermetic Rotary Compressor (Inverter-Driven) / 1 Fan unit Air volume cfm 4100 Refrigerant (*3) (Charged refrigerant amount) lb 8.6 specifications Unit MCA (*4) A Recommended fuse size A Refrigerant piping Operation temperature range Connecting port diameter Gas side (main pipe) (brazing) in 5/8 3/4 Liquid side (main pipe) (brazing) in 3/8 Cooling F DB 5~118 Heating F WB -13~64 Maximum number of connected indoor units Maximum capacity of combined indoor units 50% to 130% Sound pressure level cooling/heating (*5) db(a) (*1) Rated conditions. Cooling: Indoor air temperature 80⁰F dry bulb / 67⁰F wet bulb, Outdoor air temperature 95⁰F dry bulb Heating: Indoor air temperature 70⁰F dry bulb, Outdoor air temperature 47⁰F dry bulb / 43⁰F wet bulb (*2) The source voltage must not fluctuate more than +/- 10% (*3) The amount does not consider extra piping length. Refrigerant must be added on site in accordance with the actual piping length. (*4) Select wire size based on larger value of MCA: Miminum Circuit Amps (Minimum Circuit Amps required for power supply design) (*5) These values, measured in anechoic chamber, at a point 3.3 ft (1 m) in front of the Unit at a height of 4.6 ft (1.4m). 18

21 BRYANT VRF OUTDOOR 38VMH Heat Pump OUTDOOR UNIT 208/230V-3-60 Single module Outdoor unit model name 38VMA072HDS5-1 38VMA096HDS5-1 38VMA120HDS5-1 38VMA144HDS5-1 Nominal tons Ton Cooling capacity (*1) (with non-ducted indoor units/ducted) Heating capacity (*1) (with non-ducted indoor units/ducted) With non-ducted indoor units characteristics (Nominal) (*1) With ducted indoor units characteristics (Nominal) (*1) External dimensions Power supply (*2) Cooling Heating Power supply (*2) Cooling 19.5 Nominal kbtu/h Rated kbtu/h Nominal kbtu/h Rated kbtu/h /230V, 3-Phase, 60Hz Power consumption kw IEER (Integrated Energy Efficiency Ratio) Btu/W Power consumption kw COP (Coefficient of Performance) W/W /230V, 3-Phase, 60Hz Power consumption kw IEER (Integrated Energy Efficiency Ratio) Btu/W Power consumption kw COP (Coefficient of Performance) W/W Height in 64-3/8 Width in 52-3/4 Depth in 31-1/8 Total weight Unit lb Compressor Type/Qty Hermetic Scroll Compressor (Inverter-Driven) / 1 Hermetic Scroll Compressor (Inverter-Driven) / 2 Fan unit Air volume cfm 7,650 7,650 8,250 8,830 Refrigerant (*3) (Charged refrigerant amount) lb specifications Refrigerant piping Operation temperature range Unit Connecting port diameter MCA (*4) A Recommended fuse size A Gas side (main pipe) (brazing) in 7/8 7/8 1-1/8 1-1/8 Liquid side (main pipe) (brazing) in 3/8 3/8 1/2 1/2 Balance pipe (brazing) in 1/4 1/4 1/4 1/4 Cooling F DB 5 to 125 Heating F WB 5 to 64 Maximum external static pressure in WG 0.24 Maximum number of connected indoor units Maximum capacity of combined indoor units 50% to 135% Sound pressure level cooling/heating (*5) db(a) (*1) Rated conditions. Cooling: Indoor 80 F Dry Bulb/67 F Wet Bulb, Outdoor 95 F Dry Bulb. Heating: Indoor 70 F Dry Bulb, Outdoor 47 F Dry Bulb/43 F Wet Bulb. (*2) The source voltage must not fluctuate more than ±10% (*3) The amount does not consider extra piping length. Refrigerant must be added on site in accordance with the actual piping length. (*4) Select wire size based on larger value of MCA: Miminum Circuit Amps (Minimum Circuit Amps required for power supply design) (*5) These values, measured in anechoic chamber, at a point 3.3 ft (1 m) in front of the Unit at a height of 4.6 ft (1.4m). 19

22 38VMH Heat Pump BRYANT VRF OUTDOOR OUTDOOR UNIT 208/230V-3-60 Dual module (Combination) Combination model number 38VMA168HDS5-1 38VMA192HDS5-1 38VMA216HDS5-1 38VMA240HDS5-1 38VMA264HDS5-1 38VMA288HDS5-1 Combination units 38VMA096HDS5-1 38VMA096HDS5-1 38VMA120HDS5-1 38VMA120HDS5-1 38VMA144HDS5-1 38VMA144HDS5-1 38VMA072HDS5-1 38VMA096HDS5-1 38VMA096HDS5-1 38VMA120HDS5-1 38VMA120HDS5-1 38VMA144HDS5-1 Nominal tons Ton Cooling capacity (*1) Nominal kbtu/h (with non-ducted indoor units/ducted) Rated kbtu/h Heating capacity (*1) Nominal kbtu/h (with non-ducted indoor units/ducted) Rated kbtu/h Power supply (*2) 208/230V, 3-Phase, 60Hz With non-ducted Power consumption kw indoor units Cooling IEER (Integrated Btu/W Energy Efficiency Ratio) kw characteristics Power consumption (Nominal) (*1) Heating COP (Coefficient of Performance) W/W Power supply (*2) 208/230V, 3-Phase, 60Hz With ducted Power consumption kw indoor units Cooling IEER (Integrated Btu/W Energy Efficiency Ratio) kw characteristics Power consumption (Nominal) (*1) Heating COP (Coefficient of Performance) W/W Height in 64-3/8 External Dimensions Width in 52-3/4 x 2 Depth in 31-1/8 Total weight Unit lb 659 x x x x Hermetic Scroll Hermetic Scroll Compressor Type/Qty Hermetic Scroll Compressor (Inverter-Driven) / 2 Compressor (Inverter- Compressor (Inverter- Driven) / 3 Driven) / 4 Fan unit Air volume cfm 7,650 x 2 7,650 x 2 8, ,250 x 2 8, ,250 8,830 x 2 Refrigerant (*3) (Charged refrigerant amount) lb 37.5 x x x x x x 2 specifications Refrigerant piping Unit Connecting port diameter Operation temperature range MCA (*4) A Recommended fuse size A Gas side (main pipe) (brazing) in 1-1/8 1-1/8 1-1/8 1-1/8 1-3/8 1-3/8 Liquid side (main pipe) (brazing) in 5/8 5/8 5/8 5/8 3/4 3/4 Balance pipe (brazing) in 1/4 1/4 1/4 1/4 1/4 1/4 Cooling F DB 5 to 125 Heating F WB 5 to 64 Maximum external static pressure in WG 0.24 Maximum number of connected indoor units Maximum capacity of combined indoor units 50% to 135% Sound pressure level cooling/heating (*5) db(a) (*1) Rated conditions. Cooling: Indoor 80 F Dry Bulb/67 F Wet Bulb, Outdoor 95 F Dry Bulb. Heating: Indoor 70 F Dry Bulb, Outdoor 47 F Dry Bulb/43 F Wet Bulb. (*2) The source voltage must not fluctuate more than ±10% (*3) The amount does not consider extra piping length. Refrigerant must be added on site in accordance with the actual piping length. (*4) Select wire size based on the larger value of MCA MCA: Minimum Circuit Amps (Minimum Circuit Amps required for power supply design) (*5) These values, measured in anechoic chamber, at a point 1 m in front of the Unit at a height of 1.4m. During actual operation,these values are normally somewhat higher as a result of ambient conditions. 20

23 BRYANT VRF OUTDOOR 38VMH Heat Pump OUTDOOR UNITS 208/230V-3-60 Triple module (Combination) Combination model number 38VMA312HDS5-1 38VMA336HDS5-1 38VMA360HDS5-1 38VMA384HDS5-1 38VMA408HDS5-1 38VMA432HDS5-1 38VMA120HDS5-1 38VMA120HDS5-1 38VMA120HDS5-1 38VMA144HDS5-1 38VMA144HDS5-1 38VMA144HDS5-1 Combination units 38VMA096HDS5-1 38VMA120HDS5-1 38VMA120HDS5-1 38VMA120HDS5-1 38VMA144HDS5-1 38VMA144HDS5-1 38VMA096HDS5-1 38VMA096HDS5-1 38VMA120HDS5-1 38VMA120HDS5-1 38VMA120HDS5-1 38VMA144HDS5-1 Nominal tons Ton Cooling capacity (*1) (with nonducted indoor units/ducted) Heating capacity (*1) (with nonducted indoor units/ducted) With non-ducted indoor units characteristics (Nominal) (*1) With ducted indoor units characteristics (Nominal) (*1) External Dimensions Power supply (*2) Cooling Heating Power supply (*2) Cooling Heating Nominal kbtu/h Rated kbtu/h Nominal kbtu/h Rated kbtu/h /230V, 3-Phase, 60Hz Power consumption kw IEER (Integrated Energy Btu/W Efficiency Ratio) Power consumption kw COP (Coefficient of Performance) W/W /230V, 3-Phase, 60Hz Power consumption kw IEER (Integrated Energy Btu/W Efficiency Ratio) Power consumption kw COP (Coefficient of Performance) W/W Height in 64-3/8 Width in 52-3/4 x 3 Depth in 31-1/8 Total weight Unit lb 659 x x x x x x 3 Hermetic Scroll Hermetic Scroll Hermetic Scroll Compressor Type/Qty Hermetic Scroll Compressor (Inverter-Driven) / 3 Compressor (Inverter- Compressor (Inverter- Compressor (Inverter- Driven) / 4 Driven) / 5 Driven) / 6 Fan unit Air volume cfm 8, ,650 x 2 8,250 x 2 + 7,650 8,250 x 3 8, ,250 x 2 8,830 x 2 + 8,250 8,830 x 3 Refrigerant (*3) (Charged refrigerant amount) lb 37.5 x x x x x x 3 specifications Refrigerant piping Unit Connecting port diameter Operation temperature range MCA (*4) A Recommended fuse size A Gas side (main pipe) (brazing) in 1-3/8 Liquid side (main pipe) (brazing) in 3/4 Balance pipe (brazing) in 1/4 Cooling F DB 5 to 125 Heating F WB 5 to 64 Maximum external static pressure in WG 0.24 Maximum number of connected indoor units Maximum capacity of combined indoor units 50% to 135% Sound pressure level cooling/heating (*5) db(a) (*1) Rated conditions. Cooling: Indoor 80 F Dry Bulb/67 F Wet Bulb, Outdoor 95 F Dry Bulb. Heating: Indoor 70 F Dry Bulb, Outdoor 47 F Dry Bulb/43 F Wet Bulb. (*2) The source voltage must not fluctuate more than ±10% (*3) The amount does not consider extra piping length. Refrigerant must be added on site in accordance with the actual piping length. (*4) Select wire size based on the larger value of MCA MCA: Minimum Circuit Amps (Minimum Circuit Amps required for power supply design) (*5) These values, measured in anechoic chamber, at a point 1 m in front of the Unit at a height of 1.4m. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 21

24 38VMH Heat Pump BRYANT VRF OUTDOOR OUTDOOR UNIT 460V-3-60 Single module Outdoor unit model name 38VMA072HDS6-1 38VMA096HDS6-1 38VMA120HDS6-1 38VMA144HDS6-1 Nominal tons Ton Cooling capacity (*1) (with non-ducted indoor units/ducted) Heating capacity (*1) (with non-ducted indoor units/ducted) With non-ducted indoor units characteristics (Nominal) (*1) With ducted indoor units characteristics (Nominal) (*1) External dimensions Power supply (*2) Cooling Heating Power supply (*2) Cooling Heating Nominal kbtu/h Rated kbtu/h Nominal kbtu/h Rated kbtu/h V, 3-Phase, 60Hz Power consumption kw IEER (Integrated Energy Efficiency Ratio) Btu/W Power consumption kw COP (Coefficient of Performance) W/W V, 3-Phase, 60Hz Power consumption kw IEER (Integrated Energy Efficiency Ratio) Btu/W Power consumption kw COP (Coefficient of Performance) W/W Height in 64-3/8" Width in 52-3/4" Depth in 31-7/64" Total weight Unit lb Compressor Type/Qty Hermetic Scroll Compressor (Inverter-Driven) / 1 Hermetic Scroll Compressor (Inverter-Driven) / 2 Fan unit Air volume cfm 7,650 7,650 8,250 8,830 Refrigerant (*3) (Charged refrigerant amount) lb specifications Refrigerant piping Unit Operation temperature range Connecting port diameter MCA (*4) A Recommended fuse size A Gas side (main pipe) (brazing) in 7/8 7/8 1-1/8 1-1/8 Liquid side (main pipe) (brazing) in 3/8 3/8 1/2 1/2 Balance pipe (brazing) in 1/4 1/4 1/4 1/4 Cooling F DB 5 to 125 Heating F WB 5 to 64 Maximum external static pressure in WG 0.24 Maximum number of connected indoor units Maximum capacity of combined indoor units 50% to 135% Sound pressure level cooling/heating (*5) db(a) (*1) Rated conditions. Cooling: Indoor 80 F Dry Bulb/67 F Wet Bulb, Outdoor 95 F Dry Bulb. Heating: Indoor 70 F Dry Bulb, Outdoor 47 F Dry Bulb/43 F Wet Bulb. (*2) The source voltage must not fluctuate more than ±10% (*3) The amount does not consider extra piping length. Refrigerant must be added on site in accordance with the actual piping length. (*4) Select wire size based on larger value of MCA: Miminum Circuit Amps (Minimum Circuit Amps required for power supply design) (*5) These values, measured in anechoic chamber, at a point 3.3 ft (1 m) in front of the Unit at a height of 4.6 ft (1.4m). 22

25 BRYANT VRF OUTDOOR 38VMH Heat Pump OUTDOOR UNIT 460V-3-60 Dual module (Combination) Combination model number 38VMA168HDS6-1 38VMA192HDS6-1 38VMA216HDS6-1 38VMA240HDS6-1 38VMA264HDS6-1 38VMA288HDS6-1 38VMA096HDS6-1 38VMA096HDS6-1 38VMA120HDS6-1 38VMA120HDS6-1 38VMA144HDS6-1 38VMA144HDS6-1 Combination units 38VMA072HDS6-1 38VMA096HDS6-1 38VMA096HDS6-1 38VMA120HDS6-1 38VMA120HDS6-1 38VMA144HDS6-1 Nominal tons Ton Cooling capacity (*1) (with nonducted indoor units/ducted) Heating capacity (*1) (with nonducted indoor units/ducted) With non-ducted indoor units characteristics (Nominal) (*1) With ducted indoor units characteristics (Nominal) (*1) External Dimensions Power supply (*2) Cooling Heating Power supply (*2) Cooling Heating Nominal kbtu/h Rated kbtu/h Nominal kbtu/h Rated kbtu/h V, 3-Phase, 60Hz Power consumption kw IEER (Integrated Energy Efficiency Ratio) Btu/W Power consumption kw COP (Coefficient of Performance) W/W V, 3-Phase, 60Hz Power consumption kw IEER (Integrated Energy Efficiency Ratio) Btu/W Power consumption kw COP (Coefficient of Performance) W/W Height in 64-3/8 Width in 52-3/4 x 2 Depth in 31-1/8 Total weight Unit lb 659 x x x x Hermetic Scroll Hermetic Scroll Compressor Type/Qty Hermetic Scroll Compressor (Inverter-Driven) / 2 Compressor (Inverter- Compressor (Inverter- Driven) / 3 Driven) / 4 Fan unit Air volume cfm 7,650 x 2 7,650 x 2 8, ,650 8,250 x 2 8, ,830 8,830 x 2 Refrigerant (*3) (Charged refrigerant amount) lb 37.5 x x x x x x 2 specifications Refrigerant piping Unit Connecting port diameter Operation temperature range MCA (*4) A Recommended fuse size A Gas side (main pipe) (brazing) in 1-1/8 1-1/8 1-1/8 1-1/8 1-3/8 1-3/8 Liquid side (main pipe) (brazing) in 5/8 5/8 5/8 5/8 3/4 3/4 Balance pipe (brazing) in 1/4 1/4 1/4 1/4 1/4 1/4 Cooling F DB 5 to 125 Heating F WB 5 to 64 Maximum external static pressure in WG 0.24 Maximum number of connected indoor units Maximum capacity of combined indoor units 50% to 135% Sound pressure level cooling/heating (*5) db(a) (*1) Rated conditions. Cooling: Indoor 80 F Dry Bulb/67 F Wet Bulb, Outdoor 95 F Dry Bulb. Heating: Indoor 70 F Dry Bulb, Outdoor 47 F Dry Bulb/43 F Wet Bulb. (*2) The source voltage must not fluctuate more than ±10% (*3) The amount does not consider extra piping length. Refrigerant must be added on site in accordance with the actual piping length. (*4) Select wire size based on larger value of MCA: Miminum Circuit Amps (Minimum Circuit Amps required for power supply design) (*5) These values, measured in anechoic chamber, at a point 3.3 ft (1 m) in front of the Unit at a height of 4.6 ft (1.4m). 23

26 38VMH Heat Pump BRYANT VRF OUTDOOR OUTDOOR UNIT 460V-3-60 Triple module (Combination) Combination model number 38VMA312HDS6-1 38VMA336HDS6-1 38VMA360HDS6-1 38VMA384HDS6-1 38VMA408HDS6-1 38VMA432HDS6-1 38VMA120HDS6-1 38VMA120HDS6-1 38VMA120HDS6-1 38VMA144HDS6-1 38VMA144HDS6-1 38VMA144HDS6-1 Combination units 38VMA096HDS6-1 38VMA120HDS6-1 38VMA120HDS6-1 38VMA120HDS6-1 38VMA144HDS6-1 38VMA144HDS6-1 38VMA096HDS6-1 38VMA096HDS6-1 38VMA120HDS6-1 38VMA120HDS6-1 38VMA120HDS6-1 38VMA144HDS6-1 Nominal tons Ton Cooling capacity (*1) (with nonducted indoor units/ducted) Heating capacity (*1) (with nonducted indoor units/ducted) With non-ducted indoor units characteristics (Nominal) (*1) With ducted indoor units characteristics (Nominal) (*1) External Dimensions Power supply (*2) Cooling Heating Power supply (*2) Cooling Heating Nominal kbtu/h Rated kbtu/h Nominal kbtu/h Rated kbtu/h V, 3-Phase, 60Hz Power consumption kw IEER (Integrated Energy Btu/W Efficiency Ratio) Power consumption kw COP (Coefficient of Performance) W/W V, 3-Phase, 60Hz Power consumption kw IEER (Integrated Energy Btu/W Efficiency Ratio) Power consumption kw COP (Coefficient of Performance) W/W Height in 64-3/8 Width in 52-3/4 x 3 Depth in 31-1/8 Total weight Unit lb 659 x x x x x x 3 Hermetic Scroll Hermetic Scroll Hermetic Scroll Compressor Type Hermetic Scroll Compressor (Inverter-Driven) / 3 Compressor (Inverter- Compressor (Inverter- Compressor (Inverter- Driven) / 4 Driven) / 5 Driven) / 6 Fan unit Air volume cfm 8, ,650 x 2 8,250 x 2 + 7,650 8,250 x 3 8, ,250 x 2 8,250 x 2 + 8,830 8,830 x 3 Refrigerant (*3) (Charged refrigerant amount) lb 37.5 x x x x x x 3 specifications Refrigerant piping Unit Connecting port diameter Operation temperature range MCA (*4) A Recommended fuse size A Gas side (main pipe) (brazing) in 1-3/8 Liquid side (main pipe) (brazing) in 3/4 Balance pipe in 1/4 Cooling F DB 5 to 125 Heating F WB 5 to 64 Maximum external static pressure in WG 0.24 Maximum number of connected indoor units Maximum capacity of combined indoor units 50% to 135% Sound pressure level cooling/heating (*5) db(a) (*1) Rated conditions. Cooling: Indoor 80 F Dry Bulb/67 F Wet Bulb, Outdoor 95 F Dry Bulb. Heating: Indoor 70 F Dry Bulb, Outdoor 47 F Dry Bulb/43 F Wet Bulb. (*2) The source voltage must not fluctuate more than ±10% (*3) The amount does not consider extra piping length. Refrigerant must be added on site in accordance with the actual piping length. (*4) Select wire size based on larger value of MCA: Miminum Circuit Amps (Minimum Circuit Amps required for power supply design) (*5) These values, measured in anechoic chamber, at a point 3.3 ft (1 m) in front of the Unit at a height of 4.6 ft (1.4m). 24

27 VRF Indoor Unit Overview BRYANT VRF INDOOR Cooling Capacity kbtu/h (Ton) 4-Way Cassette Compact 4-Way Cassette High Wall Underceiling / Floor Console (Exposed) Floor Console (Recessed) 7,000 9,000 NON-DUCTED MODELS 12,000 15,000 18,000 24,000 30,000 36,000 48,000 53,500 72,000 96,000 72,000 96,000 DUCTED MODELS Cooling Capacity kbtu/h (Ton) 7,000 9,000 12,000 15,000 18,000 24,000 30,000 36,000 48,000 53,500 72,000 96,000 Low Static Duct (Slim Profile) Medium Static Duct High Static Duct Vertical AHU Outside Air Duct 25

28 40VMF 4-Way Cassette BRYANT VRF INDOOR The Bryant VRF 4-Way Cassette provides supreme comfort by delivering conditioned air flow in four directions to customize the airflow control based on user comfort preferences. Features: Integrated condensate lift up to 30" Accessories: Required panel - model # 40VMF Unit model number 40VMF VMF VMF VMF VMF VMF VMF VMF Power supply (V-Ph-Hz) 208/ Cooling capacity (Btuh) 9,000 12,000 15,000 18,000 24,000 30,000 36,000 48,000 Heating capacity (Btuh) 10,000 13,500 17,000 21,000 27,000 34,000 40,000 54,000 Indoor fan motor Type DC Input (W) Low Indoor airflow (cfm) Medium High ,100 Low Indoor unit sound Medium level db(a) High Unit dimension, 33-1/8 x 9 x 33-1/8 33-1/8 x 11-3/4 x 33-1/8 Packing dimension, 37-5/8 x 10-5/8 x 37-5/8 37-5/8 x 13 x 37-5/8 Unit Panel/grille dimension, 37-3/8 x 1-3/4 x 37-3/8 Panel/grille packing dimension, 40-7/8 x 3-5/8 x 40-7/8 Unit net/gross weight (lb) 51/66 54/71 64/82 70/87 Panel/grille net/gross weight (lb) 13.2/20 Refrigeration type R410a Expansion device EXV Design pressure, high/low (psig) 580/320 Refrigerant Liquid side, OD (Flare) 1/4 3/8 piping (in) Suction side, OD (Flare) 1/2 5/8 Connecting wiring Power wiring Sized Per NEC and Local Codes Based on Nameplate Data Signal wiring 2-Core Stranded Shielded Twisted Pair Cable 18AWG-16AWG Condensate drain pipe diameter, OD (in) 1-1/4 Condensate pump Included data MCA (A) MOPD (A) 15 26

29 BRYANT VRF INDOOR 40VMC Compact 4-Way Cassette The Bryant VRF Compact 4- Way Cassette provides supreme comfort by delivering conditioned air flow in four directions while fitting in a standard T grid ceiling. Features: Integrated condensate lift up to 24" Accessories: Required panel - model # 40VMC Unit model number 40VMC VMC VMC VMC Power supply (V-Ph-Hz) 208/ Cooling capacity (Btuh) 7,000 9,000 12,000 15,000 Heating capacity (Btuh) 8,000 10,000 13,000 17,000 Indoor fan motor Type DC Input (W) Low Indoor airflow (cfm) Medium High Indoor unit sound level db(a) Unit Low Medium High Unit dimension, 24-7/8 x 10-1/4 x 22-7/16 Packing dimension, 27-5/8 x 12-5/8 x 26 Panel/grille dimension, 25-1/2 x 2 x 25-1/2 Panel/grille packing dimension, 28-1/8 x 4-7/8 x 28-1/8 Unit net/gross weight (lb) 40/51 53/53 Panel/grille net/gross weight (lb) 5.5/9.9 R410a EXV Refrigeration type Expansion device Design pressure, high/low (psig) 580/320 Refrigerant piping (in) Liquid side, OD (Flare) 1/4 Suction side, OD (Flare) 1/2 Connecting wiring Power wiring Sized Per NEC and Local Codes Based on Nameplate Data Signal wiring 2-core stranded shielded twisted pair cable 18AWG-16AWG Condensate drain pipe diameter, OD (in) 1 Condensate pump Included data MCA (A) MOPD (A) 15 27

30 40VMW High Wall BRYANT VRF INDOOR The Bryant VRF High Wall unit provides conditioning where it wasn t possible before. The compact unit mounts on the wall, perfect for areas where there is no space above the ceiling. Features: Perfect for retrofit applications Accessories: Condensate Pump Unit model number 40VMW VMW VMW VMW VMW VMW VMW Power supply (V-Ph-Hz) 208/ Cooling capacity (Btuh) 7,500 9,500 12,000 15,000 18,000 24,000 30,000 Heating capacity (Btuh) 8,500 10,900 13,500 17,000 21,000 27,000 34,000 Indoor fan motor Type DC Input (W) Low Indoor airflow (cfm) Medium High Low Indoor unit sound Medium level db(a) High Unit dimension, 36 x 11-3/8 x /4 x 12-3/8 x 9 47 x 13-1/2 x 10-1/8 Unit Packing dimension, 40-1/8 x 15-3/8 x 12-3/8 46-1/2 x 17-1/8 x 12-7/8 50-3/4 x 15-1/8 x 18-1/8 Net/gross weight (lb) 28/35 32/ /50.5 Refrigeration type R410a Expansion device EEV Design pressure, high/low (psig) 580/320 Refrigerant piping (in) Liquid side, OD (Flare) 1/4 3/8 Suction side, OD (Flare) 1/2 5/8 Connecting wiring Power wiring Sized Per NEC and Local Codes Based on Nameplate Data Signal wiring 2-Core Stranded Shielded Twisted Pair Cable 18AWG-16AWG Condensate drain pipe diameter, OD (in) 3/4 Condensate pump Not included (field supplied, field installed) data MCA (A) MOPD (A) 15 28

31 BRYANT VRF INDOOR 40VMU Underceiling The Bryant VRF Underceiling unit does double duty by providing the capability to be installed exposed below the ceiling or floor standing as a Floor Console (Exposed) unit. This unit also has an option for outside air intake to ensure ventilation air requirements are met. Accessories: Condensate Pump Unit model number 40VMU VMU VMU VMU VMU VMU VMU Power supply (V-Ph-Hz) 208/ Cooling capacity (Btuh) 12,000 15,000 18,000 24,000 30,000 36,000 48,000 Heating capacity (Btuh) 13,500 17,000 21,000 27,000 34,000 40,000 54,000 Indoor fan motor Type DC Motor Input (W) x x 2 Low Indoor airflow (cfm) Medium ,000 High ,094 1,353 Indoor unit sound level db(a) Unit Low Medium High Unit dimension, 39 x 26 x /2 x 26 x 8 66 x 27 x 10 Packing dimension, 43 x 29-1/2 x x 29-1/2 x /2 x 30 x 13 Net/gross weight (lb) 57/71 62/75 77/90 106/128 R410a EXV Refrigeration type Expansion device Design pressure, high/low (psig) 580/320 Refrigerant piping (in) Liquid side, OD (Flare) 1/4" 3/8" Suction side, OD (Flare) 1/2" 5/8" Connecting wiring Power wiring Sized Per NEC and Local Codes Based on Nameplate Data Signal wiring 2-Core Stranded Shielded Twisted Pair Cable 20AWG-16AWG Condensate drain pipe diameter, OD (in) 5/8 Condensate pump Not included (field supplied, field installed) data MCA (A) MOPD (A) 15 29

32 40VMR Floor Console Recessed BRYANT VRF INDOOR The Bryant VRF Floor Console Recessed units can be installed inside a wall or custom-built cabinet to match interior space design. Features: External static up to 0.15 Accessories: Condensate Pump Unit model number 40VMR VMR VMR VMR VMR VMR Power supply (V-Ph-Hz) 208/ Cooling capacity (Btuh) 7,000 9,000 12,000 15,000 18,000 24,000 Heating capacity (Btuh) 8,000 10,000 13,000 17,000 20,000 27,000 Indoor fan motor Type DC Input (W) Low Indoor airflow (cfm) Medium High Indoor external static pressure in. wg 0.15 Indoor unit sound level db(a) Unit Low Medium High Unit dimension, 35-1/4 x 24 x 8-3/8 43-1/8 x 24 x 8-3/8 55 x 24 x 8-3/8 Packing dimension, 44-3/4 x 10-7/8 x 26-3/4 52-5/8 x 10-7/8 x 26-3/4 64-3/8 x 10-7/8 x 26-3/4 Net/gross weight (lb) 48.9/ / /102.1 R410a EEV Refrigeration type Expansion device Design pressure, high/low (psig) 580/320 Refrigerant piping (in) Liquid side, OD (Flare) 1/4 3/8 Suction side, OD (Flare) 1/2 5/8 Connecting wiring Power wiring Sized Per NEC and Local Codes Based on Nameplate Data Signal wiring 2-Core Stranded Shielded Twisted Pair Cable 20AWG-16AWG Condensate drain pipe diameter, OD (in) 5/8 Condensate pump Not included (field supplied, field installed) data MCA (A) MOPD (A) 15 30

33 BRYANT VRF INDOOR 40VML Low Static Duct The Bryant VRF Slim Duct (low static) unit is only 8-1/4 in height, making it an ideal candidate for narrow plenum space applications. Features: Integrated condensate lift up to 27" Bottom or rear return option Unit model number 40VML VML VML VML VML VML Power supply (V-Ph-Hz) 208/ Cooling capacity (Btuh) 7,000 9,000 12,000 15,000 18,000 24,000 Heating capacity (Btuh) 8,000 10,000 13,500 17,000 21,000 27,000 Indoor fan motor Type DC Input (W) Low Indoor airflow (cfm) Medium High Indoor external static pressure in. wg Indoor unit sound level db(a) Unit Low Medium High Unit dimension, 30-3/4 x 8-1/4 x 19-3/4 39-1/4 x 8-1/4 x 19-3/4 48 x 8-1/4 x 19-3/4 Packing dimension, 36-1/4 x 11-1/2 x /8 x 11-1/2 x /2 x 11-1/2 x 22 Net/gross weight (lb) 41/ / /71.5 R410a EEV Refrigeration type Expansion device Design pressure, high/low (psig) 580/320 Refrigerant piping (in) Liquid side, OD (Flare) 1/4 3/8 Suction side, OD (Flare) 1/2 5/8 Connecting wiring Power wiring Sized Per NEC and Local Codes Based on Nameplate Data Signal wiring 2-Core Stranded Shielded Twisted Pair Cable 20AWG-16AWG Condensate drain pipe diameter, OD (in) 1 Condensate pump Included data MCA (A) MOPD (A) 15 31

34 40VMM Medium Static Duct BRYANT VRF INDOOR The Bryant VRF Medium Static Duct unit is ideal for single room hideaway or ducted applications. Features: Integrated condensate lift up to 28" Bottom or rear return option Unit model number 40VMM VMM VMM VMM VMM VMM VMM VMM VMM Power supply (V-Ph-Hz) 208/ Cooling capacity (Btuh) 7,000 9,000 12,000 15,000 19,000 24,000 30,000 38,000 48,000 Heating capacity (Btuh) 8,000 10,000 13,500 17,000 21,000 27,000 34,000 42,000 54,000 Indoor fan motor Type DC Input (W) Low ,001 Indoor airflow Medium ,184 (cfm) High ,117 1,366 Indoor external static pressure in. wg Indoor unit sound level db(a) Unit Low Medium High Unit dimension, 39-1/4 x 8-1/4 x 19-3/4 39-3/4 x 10-5/8 x /2 x 10-5/8 x 30-1/2 50-3/4 x 11-7/8 x 34-1/8 Packing dimension, 44-7/8 x 11-1/2 x /16 x 14 x 27-3/4 54 x 14-3/8 x 33-3/4 56-1/8 x 15-5/8 x 37-3/16 Net/gross weight (lb) 48.5/ /88 97/115 99/ /143 R410a EXV Refrigeration type Expansion device Design pressure, high/low (psig) 580/320 Liquid side, OD Refrigerant (Flare) 1/4 3/8 piping (in) Suction side, OD (Flare) 1/2 5/8 Connecting wiring Power wiring Sized Per NEC and Local Codes Based on Nameplate Data Signal wiring 2-Core Stranded Shielded Twisted Pair Cable 20AWG-16AWG Condensate drain pipe diameter, OD (in) 1 3/4 Condensate pump Included data MCA (A) MOPD (A) 15 32

35 BRYANT VRF INDOOR 40VMH High Static Duct The Bryant VRF High Static Ducted indoor units can handle higher static to support longer ductwork for a given space and are ideal for hideaway applications serving multiple zones. Features: Integrated condensate lift up to 28", for sizes up to 54 Accessories: For sizes 72 and 96, condensate pump Unit model number 40VMH VMH VMH VMH VMH VMH VMH Power supply (V-Ph-Hz) 208/ Cooling Capacity (Btuh) 24,000 30,000 36,000 48,000 53,500 72,000 96,000 Heating Capacity (Btuh) Cooling Capacity (Btuh) 27,000 34,000 40,000 54,000 60,000 81, ,000 Indoor fan motor Type DC Input (W) *2 395*2 Low Indoor airflow (cfm) Medium High Indoor external static pressure in. wg Low Indoor unit Medium sound level db(a) High Unit Unit dimension, 37-1/2 x 16-1/2 x 27-3/ /16 x 16-1/2 x 27-3/ /4 x 20 x 36-7/16 Net/gross 110 / / / / weight (lb) Refrigeration type R410a Expansion device EXV Design pressure, high/low (psig) 580/320 Liquid side, OD Refrigerant (Flare) 3/8 piping (in) Suction side, OD (Flare) 5/8 7/8 Connecting wiring Power wiring Sized per NEC and Local Codes based on Nameplate data Signal wiring 2-core stranded shielded twisted pair cable 18AWG-16AWG Condensate pipe diameter, OD (in.) 1-5/8 Condensate pump Included Not included (field supplied, field installed) data MCA (A) MOPD (A) 15 33

36 40VMV Vertical AHU BRYANT VRF INDOOR The Bryant VRF Vertical Air Handling unit (AHU) is a multi-positional unit vertical and horizontal ideal for closet applications. Comes standard with a constant CFM ECM motor to ensure you always get the airflow you need. Features: Constant CFM motor Unit model number 40VMV VMV VMV VMV VMV VMV Power supply (V-Ph-Hz) 208/ Cooling capacity (Btuh) 18,000 24,000 30,000 36,000 48,000 53,500 Heating capacity (Btuh) 21,000 27,000 34,000 40,000 54,000 60,000 Indoor fan motor Type DC Input (W) Low ,120 1,260 Indoor airflow (cfm) Medium ,020 1,360 1,530 High ,000 1,200 1,600 1,800 Indoor external static pressure in. wg 0.8 Indoor unit sound level db(a) Unit Low Medium High Unit dimension, 19-5/8 x 46-1/2 x 20-5/8 22 x 54-1/2 x 24 Packing dimension, 22-5/8 x 50-5/8 x 25-3/8 24-5/8 x 58-5/8 x 27-3/4 Net/gross weight (lb) 123/ /189 R410a EXV Refrigeration type Expansion device Design pressure, high/low (psig) 580/320 Refrigerant piping (in) Liquid side, OD (Flare) 3/8 Suction side, OD (Flare) 5/8 Connecting wiring Power wiring Sized Per NEC and Local Codes Based on Nameplate Data Signal wiring 2-Core Stranded Shielded Twisted Pair Cable 20AWG-16AWG Condensate drain pipe diameter, OD (in) 3/4 NPT Condensate pump Not included (field supplied, field installed) data MCA (A) MOPD (A) 15 34

37 BRYANT VRF INDOOR 40VMA Outside Air The Bryant Outside Air unit draws in ventilation air into the space to provide fresh air. The units are installed in plenum and can be connected to a heat pump or heat recovery system along with other styles of indoor unit. Capable of providing discharge air temperature control between FDB. Features: Discharge temperature control Unit model number 40VMA VMA VMA VMA VMA Power supply (V-Ph-Hz) 208/ Cooling capacity (Btuh) 36,000 48,000 53,500 72,000 96,000 Heating capacity (Btuh) 24,000 30,000 36,000 47,000 59,000 Indoor fan motor Type DC Input (W) *2 80*2 Low Indoor airflow (cfm) Medium High Indoor external static pressure in. wg Indoor unit sound level db(a) Unit Low Medium High Unit Dimension, W x H x D (in.) 51-3/16 x 16-1/2 x 27-3/ /4 x 20 x 36-7/16 Net/Gross Weight (lb) / / R410a EXV Refrigeration type Expansion device Design pressure, high/low (psig) 580/320 Refrigerant piping (in) Liquid side, OD (Flare) 3/8 3/8 Suction side, OD (Flare) 5/8 7/8 Connecting wiring Power wiring Sized per NEC and Local Codes based on Nameplate data Signal wiring 2-core stranded shielded twisted pair cable 18AWG-16AWG Condensate pipe diameter, OD (in) 1 1-5/8 Condensate pump Included Not included (field supplied, field installed) data MCA (A) MOPD (A) 15 35

38 Individual Controls BRYANT VRF CONTROL Wireless Remote Controller Mode Setting Fan Speed Setting Set Point Display Louver Swing Setting ON / OFF Clock Setting Timer Setting Lock Function Addressing Capability 40VM Wired Remote Controller Simple, Easy to Use ON/OFF Group Control (Max 16 indoor unit) Mode Setting Fan Speed Setting Set-point Display Swing Setting Addressing Capability Back light Dual set-point control Set temperature range limiting Room Temperature Display Error Display Touch Button 1o F temperature indication Powered from indoor unit 40VM

39 BRYANT VRF CONTROL Individual Controls 40VM Programmable Wired Remote Controller Simple, Easy to Use ON/OFF Group Control (Max 16 indoor unit) Mode Setting Fan Speed Setting Set-point Display Swing Setting Addressing Capability Back light Dual set-point control Set temperature range limiting Room Temperature Display Error Display Clock Weekly Scheduling Touch Button 1o F temperature indication Powered from indoor unit 40VM Touchscreen Wired Remote Controller Display is 800*480 resolution ON/OFF Group Control (Max 16 indoor unit) Mode Setting Fan Speed Setting Set-point Display Swing Setting Addressing Capability Back light Dual set-point control Set temperature range limiting Room Temperature Display Error Display Clock Weekly Scheduling Touch Screen 1o F temperature indication Field Powered: 24VAC 37

40 Central Controls BRYANT VRF CONTROL 24V Interface Works with all VRF indoor unit Allows standard 24V thermostat connection Integration with thermostat features including Wi-Fi ON/OFF Mode Setting Fan Speed Setting Setpoint Display Backlight (dependant on thermostat) Room Temperature Display 40VM Sold Separately Côr Wi-Fi Thermostat Schedule Central Controller ON/OFF Controls up to 64 indoor unit Mode Setting Fan Speed Setting Setpoint Display Swing Setting Back light Set temperature range limiting Room Temperature Display Error Display Touch Button Field Powered: 24VAC 40VM

41 BRYANT VRF CONTROL Central Controls Touchscreen Central Controller 40VM inch screen, 1200*800 resolution 3 level of account management, can set up 20 users Remote access Alarm notification via Fire alarm and interacting information, 4 path DI and DO. Recognize units automatically Controls up to 512 indoor units & 20 outdoor units Mode Setting Fan Speed Setting Setpoint Display Swing Setting Dual set-point control Set temperature range limiting Error Display Clock Weekly Scheduling Field Powered: 24VAC 39

42 Integration BRYANT VRF CONTROL Intelligent Manager Manage 64 refrigerant system (1024 indoor units, 256 outdoor units) Monitor both outdoor and indoor unit operation Scheduling (Daily / Weekly) Energy-saving management Set temperature range limit lock mode etc. Group management Export Software log 40VM BACnet Four 485 ports, each port can access 64 indoor units or 8 refrigeration system WEB service allows log in through web Indoor unit Temperature set Indoor temperature Operate mode Error code Set mode Outdoor unit Mode Outdoor temperature Error code 40VM Lonworks Supports 64 indoor units Indoor unit»» Temperature set»» Indoor temperature»» Operate mode»» Fault code Outdoor unit»» Mode»» Fault»» Outdoor temperature»» Fault code 40VM

43

44 For more than a century, homeowners have associated Bryant heating and cooling products with the highest standards of indoor comfort and Bryant dealers as service leaders. Through commitment and dedication of our product development and manufacturing teams, we have consistently met every new challenge head-on and delivered the products to meet or exceed expectations. Our national network of passionate Bryant dealers is at the forefront of our success. Knowledgeable in the field, and equipped to address home comfort needs, our dealers deliver customized comfort solutions to homeowners by doing Since 1904 Visit our website at BryantVRF.com Manufacturer reserves the right to discontinue, or change at any time, specification or designs without notice or without incurring obligations West Morris Street, Indianapolis, IN Wi-Fi is a registered trademark of Wi-Fi Alliance Corporation. A Member of the United Technologies Corporation Family. Stock Symbol UTX. Bryant Heating and Cooling Systems /2017

Variable Refrigerant Flow

Variable Refrigerant Flow Variable Refrigerant Flow Two-pipe Heat Recovery and Heat Pump Systems Heat Recovery Single-chassis Design Heat Pump Modular Design Table of Contents Carrier VRF Advantages 2 Revolutionary Design 3 Advanced

More information

CARRIER DUCTLESS & VRF SYSTEMS. What s Next in Comfort

CARRIER DUCTLESS & VRF SYSTEMS. What s Next in Comfort CARRIER DUCTLESS & VRF SYSTEMS What s Next in Comfort Table of Contents 4 Ductless Benefits 14 Single Zone and Multi-zone Product Lineup 17 Single Zone Products 43 Multi-zone Products 55 Light Commercial

More information

Engineering Data Book

Engineering Data Book 40VMF 4-Way Cassette Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

Engineering Data Book

Engineering Data Book 40VMU Under Ceiling/Floor Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs

More information

Engineering Data Book

Engineering Data Book 40VMC Compact 4-Way Cassette Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs

More information

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System Submittal Data: Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Compact and Quiet Design -High Efficiency DC Inverter Technology -Wireless Remote

More information

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 12,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 24,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Residential and Light Commercial Ductless Systems Catalog

Residential and Light Commercial Ductless Systems Catalog Residential and Light Commercial Ductless Systems Catalog May 2018 Table of Contents Midea Global 3 Ductless Benefits 5 Single and Multi-Zone Solutions 9 Single Zone Residential 13 Max Series 15 Advantage

More information

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Submittal Data: Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Submitted to Reference Approval Construction Unit Designation Schedule #

Submitted to Reference Approval Construction Unit Designation Schedule # Page 1of5 Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # System Performance Modules Connected US Ton (nominal) Capacity (Btu/h) System Specifications

More information

Engineering Data Book

Engineering Data Book 40VMV Vertical Air Handling Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs

More information

LG VRF Systems. Air Conditioning Technologies

LG VRF Systems. Air Conditioning Technologies LG VRF Systems Air Conditioning Technologies 2018 ABOUT LG ABOUT LG VRF A Variable Flow (VRF) system is a single refrigerant circuit that connects many indoor units to one outdoor unit. VRF is a superior

More information

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series Commercial Air Conditioners 2017/2018 VRF 50/60Hz V5 X Series Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation and

More information

NFZP Variable Refrigerant Flow Guide Specification

NFZP Variable Refrigerant Flow Guide Specification PART 1 - GENERAL 1.01 SECTION INCLUDES SECTION 23 81 29 VARIABLE REFRIGERANT FLOW HVAC SYSTEM A. (VRF) HVAC system includes: 1. Outdoor/Condensing unit(s): a. Size Range: 14 Tons Nominal b. YANMAR VRF

More information

Engineering Data Book

Engineering Data Book 40VML Low Static Ducted Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP VEP075N432G Job Name: Location: Schedule No.: System Designation: Engineer: Architect: Date: For: Reference Approval Review Construction FEATURES Two-pipe heat pump Access to electrical box for ease of

More information

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

Submitted to Reference Approval Construction Unit Designation Schedule #

Submitted to Reference Approval Construction Unit Designation Schedule # Page 1of Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # System Performance Power Indoor Units Modules Connected US Ton (nominal) Capacity

More information

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI 24,000 BTUH 24,000 Ceiling BTU/H Cassette Ceiling Heat Casse3e Pump Heat System Pump System Job Name Location Date Purchaser

More information

DUCTLESS FULL LINE CATALOG

DUCTLESS FULL LINE CATALOG DUCTLESS FULL LINE CATALOG Spring 2016 Edition 1 Versatile Ductless Systems can increase your sales opportunities Bryant offers a complete line of ductless HVAC systems designed to make any space more

More information

Product Line Introduction. Karl Zhang Technical support engineer

Product Line Introduction. Karl Zhang Technical support engineer Product Line Introduction Karl Zhang Technical support engineer Air Conditioning Solutions Heating & Hot Water Solutions Control Solutions Air Conditioning Solutions Residential Application Commercial

More information

VRV LIFE FLEXIBLE / DUAL-FUEL HEATING / INVERTER TECHNOLOGY / QUIET / SPACE-SAVING

VRV LIFE FLEXIBLE / DUAL-FUEL HEATING / INVERTER TECHNOLOGY / QUIET / SPACE-SAVING VRV LIFE FLEXIBLE / DUAL-FUEL HEATING / INVERTER TECHNOLOGY / QUIET / SPACE-SAVING DAIKIN VRV LIFE Re-inventing residential air-conditioning by breaking technological barriers, Daikin VRV LIFE systems

More information

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless

More information

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz COMMERCIAL AIR CONDITIONERS R40A All DC Inverter VRF V5 X Series 50/60Hz Midea CAC (MCAC) As a key subsidiary of Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading

More information

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -Medium Static Pressure Capability -Return

More information

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8. Submittal Data: CROWN09HP230V1B Superior Performance in Extreme Temperature 9,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule

More information

DUCTLESS & VRF PRODUCT FAMILY BROCHURE. IT TAKES your comfort to new places.

DUCTLESS & VRF PRODUCT FAMILY BROCHURE. IT TAKES your comfort to new places. DUCTLESS & VRF PRODUCT FAMILY BROCHURE IT TAKES your comfort to new places. Spring 2017 Versatile Ductless & VRF Systems fit practically any need. Bryant offers a complete line of Ductless & VRF HVAC systems

More information

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value. Midea Ducted and Cassette Split Systems Maximum versatility, maximum value. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

Inverter Ducted Split Air Source Heat Pump. Simply Smart. System with Inverter Drive Technology. boschheatingandcooling.com

Inverter Ducted Split Air Source Heat Pump. Simply Smart. System with Inverter Drive Technology. boschheatingandcooling.com Inverter Ducted Split Air Source Heat Pump System with Inverter Drive Technology Simply Smart The robust Bosch Inverter Ducted Split air-source heat pump system utilizes just the right amount of energy

More information

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C) Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Internal Condensate

More information

VRF Outdoor Units. YMGI Group 601 Arrow Ln, O Fallon, MO ymgigroup.com Solar Series Mini & Modular

VRF Outdoor Units. YMGI Group 601 Arrow Ln, O Fallon, MO ymgigroup.com Solar Series Mini & Modular MI NG Your Modern Green Idea NI SP L IT S VRF ED PTAC SOLAR L LIG HT I Solar Series Mini & Modular VRF Outdoor Units Ultra Heating Mini & Modular Heat Recovery Modular FEATURES & SPECIFICATIONS YMGI Group

More information

2017 LINE UP MINI SPLITS CATALOG

2017 LINE UP MINI SPLITS CATALOG SINGLE ZONE MULTI ZONE LIGHT COMMERCIAL 2017 LINE UP MINI SPLITS CATALOG Residential & Light Commercial Solutions WELCOME SERVICE & SUPPORT We believe that the best way to ensure the complete satisfaction

More information

ELECTRICAL QUANTITY WEIGHT (LB)

ELECTRICAL QUANTITY WEIGHT (LB) VRF SYSTEM INDOOR UNIT ENTERING AIR TEMPERATURES ( F) CAPACITIES (kbtuh) Max SOUND ELECTRICAL WEIGHT TOSHIBA-CARRIER COOLING HEATING Airflow PRESSURE, MARK NO. TYPE ROOM TOTAL SENSIBLE HEATING V / Ø /

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS 8MGR Multi-zone Outdoor Unit Ductless System Sizes 18, 24, 0, 6 and 48 Fig. 1 18K Fig. 2 24K and 0K Product Data INDUSTRY LEADING FEATURES / BENEFITS A competitively priced and creative solution to design

More information

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 Product Data INDUSTRY LEADING FEATURES / BENEFITS AN INEXPENSIVE AND

More information

A single answer for multiple zones.

A single answer for multiple zones. FJM - Free Joint Multi A single answer for multiple zones. More comfort with less. This powerful unit supports up to five indoor units for multi-zone control with one outdoor unit. It s also available

More information

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System For Residential & Light Commercial Applications 4 Ton 8 Zone Multi Split Heat Pump System EXPERTISE AND INNOVATION The Super Multi PLUS Split System is the ultimate, flexible solution for individual zone

More information

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE GREE Multi 21 systems, with inverter technology, are some of today s most advanced ductless split heat pumps. Providing both cooling and heating

More information

Variable Refrigeration Flow Systems Overview 10/11/2016

Variable Refrigeration Flow Systems Overview 10/11/2016 Variable Refrigeration Flow Systems Overview 10/11/2016 Executed by Data Power Technology Illinois Aggressively, relentlessly anticipating and exceeding our customer s and client s expectations every day,

More information

A single answer for multiple zones.

A single answer for multiple zones. Free Joint Multi (FJM) A single answer for multiple zones. More comfort with less. This powerful unit supports two to five indoor units for multi-zone control with one outdoor unit. It s also available

More information

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems www.emiretroaire.com PN 240012598 REV. [03/20/2019] Single Zone & Multi-Zone Systems Deluxe Heat Series HEAT PUMP ductless mini splits with

More information

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS Now Only One Unit Required for Initial Start-up L Multi Zone Inverter Heat Pump High Efficiency Multi 21+ heat pump units can heat and cool up to 5 zones without

More information

HEAT PUMPS. Efficient Comfort For Every Season

HEAT PUMPS. Efficient Comfort For Every Season HEAT PUMPS Evergreen Series Efficient Comfort For Every Season 1 Evergreen Series Efficient Comfort For Every Season THE WORLD S MOST EFFICIENT HEAT PUMP The Yukon series is rated the world s most efficient

More information

SINGLE-ZONE CEILING-CONCEALED DUCTED SYSTEM ENGINEERING MANUAL

SINGLE-ZONE CEILING-CONCEALED DUCTED SYSTEM ENGINEERING MANUAL SINGLE-ZONE CEILING-CONCEALED DUCTED SYSTEM ENGINEERING MANUAL Single-Zone Ceiling-Concealed Ducted Heat Pump Systems 3/4 to 3 Tons Low Static LD097HV4 (9,000 Btu/h) LD127HV4 (12,000 Btu/h) High Static

More information

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer V4 Plus Heat Recovery VRF Linda Lin Pre-sales Engineer VRF Line-up DC inverter VRFs 2-pipe 3-pipe Combinable Individual Watercooled Mini Heat recovery V5 X 8-88HP V4+S 8-64HP V4+I (side) 20-45kW V4+I (top)

More information

Advance Split

Advance Split Engineering Data Manual Aqu@Scop Advance Split Air-to-Water DC Inverter Split Heat Pumps Models 005, 008, 012 & 014 2 to 16 kw Strength Points Most efficient heating technology with variable speed compressor.

More information

THE WORLD S MOST EFFICIENT HEAT PUMP

THE WORLD S MOST EFFICIENT HEAT PUMP HEAT PUMPS THE WORLD S MOST EFFICIENT HEAT PUMP The LOMOPLUS is rated the world s most efficient heat pump in both cooling and heating modes and also in every capacity from 9,000 BTU to 24,000 BTU. Being

More information

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center Mechanical Contractor Company: Contact: Phone: Address:, Distributor Branch

More information

Variable Refrigerant Flow (VRF) Multi-Zone Systems

Variable Refrigerant Flow (VRF) Multi-Zone Systems Variable Refrigerant Flow (VRF) Multi-Zone Systems Commercial Catalog 2016 One System - Up to 36 Zones Easy Installation Quiet Operation Energy Efficient Compact Modular Design Smart technology for efficient

More information

Increase your flexibility.

Increase your flexibility. DVM CHILLER Increase your flexibility. Get the best of two worlds. This easy to expand, modular unit combines the benefits of VRF and Chiller systems. Product Registration Required Conditions Apply 2018

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY

More information

ECOi TM. Variable Refrigerant Flow (VRF), Multi-Zone, Heat Pump & Heat Recovery Systems

ECOi TM. Variable Refrigerant Flow (VRF), Multi-Zone, Heat Pump & Heat Recovery Systems ECOi TM Variable Refrigerant Flow (VRF), Multi-Zone, Heat Pump & Heat Recovery Systems ECOi Building Your Business. Panasonic has a proud global heritage and over 5 years experience in the United States

More information

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF 2016 Commercial Air Conditioners VRF 60Hz V4+SV4+RV4+WMini VRF OUTDOOR UNIT LINEUP INDOOR UNIT LINEUP 1.8 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 10.0 11.2 12.5 14.0 16.0 20.0 25.0 28.0 40.0 45.0 OUTDOOR UNIT

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS 8MGR Multi-zone Outdoor Unit Ductless System Sizes 18, 24, 0, 6 and 48 Fig. 1 18K Fig. 2 24K and 0K Product Data INDUSTRY LEADING FEATURES / BENEFITS A competitively priced and creative solution to design

More information

Single and Multi-Zone Ductless Split Systems

Single and Multi-Zone Ductless Split Systems Presents Single and Multi-Zone Ductless Split Systems EnviroAir Ductless Split Systems by EMI provide homeowners and light commercial establishments economical solutions when only area cooling and heating

More information

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG: M4MCW1509A-SUB-1C TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity

More information

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP www.mitsubishielectric.ca P-SERIES The Attraction of Being Untraditional Mr. Slim P-Series is the ductless solution for demanding environments that

More information

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES turn to the experts SM R 410A DC INVERTER LIGHT COMMERCIAL SERIES DC Inverter Technology More Economical Energy Efficient Once indoor air temperatures reach your desired levels, inverter driven air-conditioners

More information

Superior Technology and Integration VARIABLE REFRIGERANT FLOW SYSTEMS

Superior Technology and Integration VARIABLE REFRIGERANT FLOW SYSTEMS Superior Technology and Integration VARIABLE REFRIGERANT FLOW SYSTEMS Efficient, Cost-Effective Comfort Contents n WHY VRF 2 Next-Generation Capabilities...2 Next-Generation Control...3 Ultimate Flexibility...4

More information

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house. Midea Ducted and Cassette Split Systems Year round comfort, all around the house. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG: M4MLW1809A-SUB-1A TAG: 18 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA MODEL - Heat Pump Only RATED Volts/PH Frequency (Hz) Rated Cooling / Heating

More information

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 5.16 LIGHT COMMERCIAL RESIDENTIAL AIR COOLED RENOVATION NEW CONSTRUCTION

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 5.16 LIGHT COMMERCIAL RESIDENTIAL AIR COOLED RENOVATION NEW CONSTRUCTION ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 5.16 LIGHT COMMERCIAL RESIDENTIAL AIR COOLED RENOVATION NEW CONSTRUCTION What is Daikin VRV IV S-series? One flexible package Daikin VRV IV S-series

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

ductless mini-splits light commercial and multi-zone systems product catalog ALEGRIA ALEGRIA

ductless mini-splits light commercial and multi-zone systems product catalog ALEGRIA ALEGRIA ALEGRIA PLATINUM SERIES ALEGRIA GOLD SERIES ductless mini-splits light commercial and multi-zone systems 2017 product catalog comfortstar 2 ductless mini-splits Series to choose from With over 50 years

More information

Ultimate VRF System R410A, 50Hz

Ultimate VRF System R410A, 50Hz Ultimate VRF System R410A, 50Hz TVR WIZ Systems, a new leap in technology and innovation A proven solution from a trusted advisor Trane is proud to present their new line of variable refrigerant systems,

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

Ductless Split Systems Wall-mounted, Single Zone Heat Pump Ductless Split Systems Wall-mounted, Single Zone Heat Pump PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H

More information

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE GREE Multi 21 systems, with inverter technology, are some of today s most advanced ductless split heat pumps. Providing both cooling and heating

More information

Cold Remedies. SamsungHVAC.com. Product Registration Required Conditions Apply

Cold Remedies. SamsungHVAC.com. Product Registration Required Conditions Apply Cold Remedies. Meet the Max Heat family. The ideal solutions for the harshest of colds. Our Max Heat units provide high heating capacity at -13 F to keep you comfortable. Look inside for our complete line

More information

Lennox Mini-Split Systems Year-Round Comfort and Performance

Lennox Mini-Split Systems Year-Round Comfort and Performance Lennox Mini-Split Systems Year-Round Comfort and Performance Single- and Multi-Zone Heat Pump Systems UP TO 24.0 SEER AND 11.0 HSPF The solution that works where others won t. LENNOX MINI-SPLIT AT A GLANCE:

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MBQ Outdoor Unit Single Zone Ductless System Sizes 36 to 48

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MBQ Outdoor Unit Single Zone Ductless System Sizes 36 to 48 38MBQ Outdoor Unit Single Zone Ductless System Sizes 36 to 48 Product Data INDUSTRY LEADING FEATURES / BENEFITS A PERFECT BALANCE BETWEEN BUDGET LIMITS, ENERGY SAVINGS AND COMFORT. The 38MBQ series ductless

More information

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems HVRF YLM Series AN2.1 - NZ The Hybrid VRF Advantage "Water, rather than traditional refrigerant, is at the heart of the indoor units. This means

More information

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron. Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 1984 saw Advanced Australia Fair become

More information

Heating & Cooling Products

Heating & Cooling Products Heating & Cooling Products Ductless Product Catalog Spring 2017 Heating & Cooling Products PRODUCT OVERVIEW Energy-Efficient Advanced inverter technology allows systems to achieve excellent energy efficiencies,

More information

SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule #

SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule # Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # Page 1 of 7 Performance Power Compressor 95 F Ambient, Entering Temperature: 54 F, Leaving

More information

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18 Submittal Sheet Submitted for: Approval Record Job Name: Contractor: Engineer: Date: Location: Tag: AIR-CON MULTI-SPLIT II Indoor Units Outdoor Unit High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

More information

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON 7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products

More information

VRF Series. The most advanced commercial air conditioning system

VRF Series. The most advanced commercial air conditioning system VRF Series The most advanced commercial air conditioning system 4 The most advanced commercial air conditioning solution As a world-wide leader in electronics Toshiba not only develops new technologies

More information

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium

More information

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG: M4MHW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA 2017 Ingersoll Rand All Rights Reserved MODEL - Heat Pump Only RATED Volts/PH

More information

Air Conditioning & Heating. Ductless Product Catalog

Air Conditioning & Heating. Ductless Product Catalog Air Conditioning & Heating Ductless Product Catalog PRODUCT OVERVIEW Energy-Efficient Advanced inverter technology allows systems to achieve excellent energy efficiencies, up to 30.5 SEER, 10.3 HSPF and

More information

Commercial Air Conditioners VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF

Commercial Air Conditioners VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF Coercial Air Conditioners 2016 VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation

More information

Air-Cooled Condensing Units with Compact Screw Compressors

Air-Cooled Condensing Units with Compact Screw Compressors LK-SCUTB March 2015 Air-Cooled Condensing Units with Compact Screw s Technical Bulletin Models SSV DSV Table of Contents Nomenclature Chart... 2 Introduction... 3 Bitzer TM s... 4 Magnum TM Microprocessor...

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

Product Data. 38MAQ Outdoor Unit Single Zone Ductless System Sizes 09 to 30 INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 38MAQ Outdoor Unit Single Zone Ductless System Sizes 09 to 30 INDUSTRY LEADING FEATURES / BENEFITS 38MAQ Outdoor Unit Single Zone Ductless System Sizes 09 to 30 Product Data INDUSTRY LEADING FEATURES / BENEFITS A PERFECT BALANCE BETWEEN BUDGET LIMITS, ENERGY SAVINGS AND COMFORT. The 38MAQ series ductless

More information

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron. Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 198 saw Advanced Australia Fair become

More information

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC January 2018 Engineering Data RXSQ24-60TAVJU Heat Pump 208/230V / 60 Hz / 1 ph Presales Manual DAIKIN NORTH AMERICA LLC DAIKIN NORTH AMERICA LLC RXSQ_TAVJU VRV LIFE TM Heat Pump Unit Contents 1. Features

More information

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron. Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 1984 saw Advanced Australia Fair become

More information

Advance Product Data

Advance Product Data Infinityr 19VS Variable Speed Air Conditioner 2, 3, and 4---Ton (5---Ton Coming Q4 2014) Advance Product Data The Infinity 19VS air conditioner offers high -efficiency variable speed performance in a remarkably

More information

Technical Product Guide

Technical Product Guide RIO Ductless Mini-Split Heat Pump 9,000 24,000 BtuH Technical Product Guide Compact & Quiet Solution Table of Contents 1.0 PRODUCT OVERVIEW 3 2.0 FEATURES AND BENEFITS 3 3.0 PRODUCT NOMENCLATURE 6 4.0

More information

K sin. Mini Split Air Conditioners and Heat Pump

K sin. Mini Split Air Conditioners and Heat Pump Mini Split Air Conditioners and Heat Pump K sin Environment concern is a priority all over the world. Environment concern is our responsibility and working philosophy. 140 105 70 35 Noise Level db(a) Level

More information

Samsung 360 Cassette, Single Zone, Split System

Samsung 360 Cassette, Single Zone, Split System Job Name Purchaser Submitted to Unit Designation Location Engineer Reference Schedule # Approval Page 1 of 5 Construction Specifications Model Indoor Unit Model Number Outdoor Unit Model Number Nominal

More information

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group VRF D4 PLUS System Digital Scroll Series GD Midea Heating & Ventilating Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 GD Midea Heating

More information

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw) Product Data 38AH024-134 Commercial Air-Cooled Condensing Units 50/60 Hz 20 to 130 Nominal Tons (63 to 390 Nominal kw) a38-4143ef 38AH044-134 These dependable split systems match Carrier s 40RM or 39 Series

More information

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design Special Heat Exchanger Design 4 way air return heat exchanger design Reduce the heat exchanger height (6mm), and the upper and lower wind speed uniform and high efficiency. Air Supply Chamber and Equipment

More information

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG: M4MCW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity

More information

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED

More information