Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE 3 -PASS PRIMARY HEAT EXCHANGERS FLOW -THROUGH SECONDARY HEAT EXCHANGERS MONOPORT INSHOT BURNERS

Size: px
Start display at page:

Download "Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE 3 -PASS PRIMARY HEAT EXCHANGERS FLOW -THROUGH SECONDARY HEAT EXCHANGERS MONOPORT INSHOT BURNERS"

Transcription

1 MULTIPOISE CONDENSING GAS FURCE Product Data INSTALLATION FLEXIBILITY The 4 -way multipoise design allows a model to be installed in an upflow, downflow, hizontal ientation. All sizes of the may be installed in direct vent (2 -pipe) applications. All sizes except the 1 size may be installed in non - direct vent (1 -pipe) applications. The 1 size also has an elevation limitation of,000 ft. See Combustion Air and Vent Pipe table f me infmation. CASING The casing also has the required openings f left- right-side connection of gas, electric, drain, and vent connections. COMBUSTION SYSTEM Enclosed burner assembly isolates operating noise without the expense of sound deadening devices. 3 -PASS PRIMARY HEAT EXCHANGERS This design accelerates heat transfer and extracts heat that conventional heat exchangers waste up the flue. The primary heat exchanger is made of aluminized steel f crosion resistance. FLOW -THROUGH SECONDARY HEAT EXCHANGERS Each cell is laminated with our patented polypropylene f greater crosion resistance to help extend the life of the furnace f years of dependable perfmance. The heat exchanger is positioned in the furnace to extract additional heat from the combustion products regardless of furnace ientation. MONOPORT INSHOT BURNERS Produce precise air-to -gas mixture which gives a clean burn. The large monopt on the inshot injection -type burners seldom, if ever, needs cleaning. INTEGRATED CONTROL CENTER The printed -circuit board has convenient terminals which permit quick -connection of a thermostat, air conditioning control circuits, a humidifier, an air cleaner. The control has a built-in status indicat and self -test feature. A self -test feature allows f a complete check of the maj components in about seconds. The control also features an adjustable blower off delay. COMBUSTION AIR AND VENTILATION The advanced design allows f a variety of non -metallic venting materials to bring air into the furnace f combustion and f venting combustion products outside the structure. The vent pipe can terminate through a sidewall through the roof. In the United States, Schedule PVC, Schedule CPVC pipe and fittings, PVC -DWV, SDR -21 PVC, SDR -26 PVC, ABS -DWV, ABSF8 Schedule pipe may be used. Installation in Canada must confm to the requirements of CSA B1 code. Vent systems MUST be composed of pipe, fittings, cements,and primers listed to ULC S636. Thespecial vent fittings and accessy concentric vent termination kits and accessy external drain trap have been certified to ULC S636 f use with those IPEX PVC vent components which have been certified to this standard. CERTIFICATIONS The units are Canadian Standards Association (CSA) design certified f use with natural and propane gases, as well as Air Conditioning, Heating and Refrigeration Institute (AHRI) efficiency rating certified. The furnace is facty -shipped f use with natural gas. A CSA listed gas conversion kit is required to convert furnace f use with propane gas. The model PG9MAA meets Califnia Air Quality Management District emission requirements. QUALITY REGISTRATION The quality systems f this product have been registered by ULto ISO 9001 Standards.

2 DIMENSIOL DRAWING CONDENSATE DRAIN TRAP " LOCATION TYP (ALTERTE UPFLOW) " " SIDE INLET TYP 16" 1 1 4" 1" " " " 22 16" 2-IN. COMBUSTION- AIR CONN 1 2-IN. DIA GAS CONN 2-IN. VENT CONN 1 2-IN. DIA THERMOSTAT ENTRY " " TYP SIDE INLET " TYP CONDENSATE DRAIN TRAP LOCATION (DOWNFLOW & HORIZONTAL LEFT) 8-IN. DIA POWER CONN 8-IN. DIA ACCESSORY POWER ENTRY 9 16" TYP CONDENSATE DRAIN LOCATION (UPFLOW) " 2 TYP 8" 13 /16" " TYP 32 8" TYP 13 16" 11 /16" AIRFLOW A D 13 /16" OUTLET INLET E 11 /16" NOTES: Minimum return-air opening at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer's recommendation f equivalent diameters: 1. F 800 CFM 16-in. round 14-1 /2 X -in. rectangle. 2. F 10 CFM -in. round 14-1 /2 X 19-1 /2 in. rectangle. 3. F 10 CFM 22-in. round 14-1 /2 X 23-1 /4 in. rectangle. 4. F airflow requirements above 1800 CFM, see Air Delivery Table in product Specification Sheet f specific use of single side inlets. The use of both side inlets, a combination of 1 side and the, the only will ensure adequate return-air openings f airflow requirements above 1800 CFM at 0. W.C. ESP. CONDENSATE DRAIN TRAP LOCATION (DOWNFLOW & HORIZONTAL RIGHT) OR ALTERTE 1 2-IN. DIA GAS CONN 1 2" " 9 16" TYP CONDENSATE DRAIN LOCATION (UPFLOW) DIMPLE LOCATORS FOR HORIZONTAL HANGING " " " 22 16" 19" OUTLET 2-IN. COMBUSTION- AIR CONN 1 2-IN. DIA GAS CONN " " TYP " BOTTOM INLET 8-IN. DIA POWER CONN 1 2-IN. DIA THERMOSTAT ENTRY 2-IN. VENT CONN SIDE INLET Dimensions --- IN. (mm) A D E 02-1/2 () 1-/8 (3) 16 (6) 03-1/2 () 1-/8 (3) 16 (6) 02-1/2 () 1-/8 (3) 16 (6) 03-1/2 () 1-/8 (3) 16 (6) 00-1/2 () 1-/8 (3) 16 (6) /2 () 1-/8 (3) 16 (6) /2 () 1-/8 (3) 16 (6) (33) 19-3/8 (2) 19-1/2 () (33) 19-3/8 (2) 19-1/2 () (33) 19-3/8 (2) 19-1/2 () /2 (2) 22-/8 (81) 23 (84) /2 (2) 22-/8 (81) 23 (84) 13 16" 8" 16" 39 8" 1" 16" 11 16" A0218 2

3 CONDENSATE TRAP BLOWER SHELF CONDENSATE TRAP (INSIDE) FURCE DOOR CONDENSATE TRAP FURCE SIDE FURCE DOOR FURCE SIDE mm 4 2 mm mm mm 4 ALTERTE DRAIN TUBE LOCATION CONDENSATE TRAP DRAIN TUBE LOCATION UPFLOW APPLICATIONS 19 mm 3 4 FIELD DRAIN CONN SLOT FOR SCREW HORIZONTAL APPLICATION (OPTIOL) mm WIRE TIE GUIDES (WHEN USED) mm mm FIELD 4 66 mm 38 mm DRAIN CONN SIDE VIEW FRONT VIEW END VIEW FRONT VIEW DOWNFLOW AND ALTERTE EXTERL UPFLOW APPLICATIONS mm 8 22 mm mm 1 /4 OD COLLECTOR BOX TO TRAP RELIEF PORT 1 /2 OD INDUCER HOUSING DRAIN CONNECTION /8 OD COLLECTOR BOX DRAIN CONNECTION SCREW HOLE FOR UPFLOW OR DOWN- FLOW APPLICATIONS (OPTIOL) 1 /2-IN. PVC OR CPVC HORIZONTAL APPLICATIONS mm FRONT VIEW SIDE VIEW A926 D E S I G N Always Ask F C E R T I F I E D CERTIFIED Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. F verification of certification f individual products, go to 3

4 SPECIFICATIONS RATINGS AND PERFORMANCE Input Btuh* Output Capacity BTUH* (ICS) (Shaded capacities are specified on rating plate) AFUE% Nonweatherized ICS Direct Vent (2 --- Pipe) Non --- Direct Vent (1 --- Pipe) Direct Vent (2 --- Pipe) Non --- Direct Vent (1 --- Pipe) Upflow 3,000 3,000 6,000 6,000 6,000 4,000 Downflow 3,000 3,000 6,000 6,000 6,000 4,000 Hizontal 3,000 3,000 6,000 6,000 6,000 4,000 Upflow 3,000 3,000 6,000 6,000 6,000 4,000 Downflow 3,000 3,000 6,000 6,000 6,000 4,000 Hizontal 3,000 3,000 6,000 6,000 6,000 4,000 Upflow Downflow Hizontal Upflow 90 Downflow 90 Hizontal 90 Certified Temperature Rise Range F Certified External Static Pressure Heating Cooling Airflow CFM Heating Cooling ELECTRICAL Unit Volts Hertz Phase 11 1 Operating Voltage Range Min Max** 4 Maximum Unit Amps Unit Ampacity Minimum Wire Size Maximum Wire Length (Ft) Maximum Fuse Size Ckt Bkr Amps (Time---Delay Type Recommended) Transfmer (24v) va External Control Heating va Power Available Cooling 21va Air Conditioning Blower Relay Standard CONTROLS Limit Control SPST Heating Blower Control (Off Delay) Selectable 90, 1, 10, 180 Burners (Monopt) Gas Connection Size 1/2 ---in. NPT GAS CONTROLS Manufacturer White --- Rodgers Minimum Inlet Pressure Gas Valve (Redundant) (In. W.C.) 4. (Natural Gas) Maximum Inlet Pressure (In. W.C.) 13.6 (Natural Gas) Ignition Device Hot Surface BLOWER DATA Direct---Drive Mot HP (Permanent Split Capacit) 1/ 1/3 1/ 1/3 1/2 1/3 Mot Full Load Amps RPM (Nominal) Speeds Blower Wheel Diameter x Width (In.) X 6 X X 6 X 11 X 8 X Filter Size (In.) Permanent Washable (1) 16 X 2 X 3/4 (1) X 2 X 3/4 FACTORY---AUTHORIZED AND LISTED, DEALER---INSTALLED OPTIONS Gas Conversion Kit Natural --- to --- Propane KGANP41ALL Gas Conversion Kit Propane --- to --- Natural KGAPN3901ALL Twinning Kit N/A KGATW 01HSI N/A Manufactured (Mobile) Home Kit KGAMH01KIT Downflow Base*** KGASB01ALL Vent Termination Kit (Bracket Only f 2 Pipes) 2---in. KGAVT01BRA 3---in. KGAVT01BRA Vent Termination Kit (Single Exit) 2---in. KGAVT01CVT 3---in. KGAVT0801CVT Condensate Freeze Protection Kit KGAHT01CFP Side Filter Rack (Without Filter) Upflow KGAFR01ALL Condensate Neutralizer Kit (obtained thru RCD) P Do Gasket Kit KGBAC01DGK * Gas input ratings are certified f elevations to 00 ft. F elevations above 00 ft, reduce ratings 2 percent f each 00 ft above sea level. In Canada, derate the unit percent from 00 to 0 ft above sea level. Capacity and AFUE in accdance with U.S. Government DOE test procedures. Airflow shown is f only return---air supply. F air delivery above 1800 CFM, see Air Delivery table f other options. A filter is required f each return---air supply. ** Permissible voltage limits f proper furnace operation. Unit ampacity = percent of full load amps of largest components plus 0 percent full load amps of all other potential operating components (EAC, humidifier, etc.). Length shown is measured 1 way along wire path between unit and service panel f maximum 2 percent voltage drop. *** Required f installation on combustible flos when no coil box is used, when any coil box other than a Payne CD, CK KCAKC cased coil is used. F direct vent applications only. N/A---Not Applicable. Unit is not allowed in this installation application. ICS---Isolated Combustion System 4

5 SPECIFICATIONS (CONTINUED) RATINGS AND PERFORMANCE Input Btuh* 0,000 0,000 1, ,000 Output Capacity BTUH* (ICS) (Shaded capacities are specified on rating plate) AFUE% Nonweatherized ICS Direct Vent (2 --- Pipe) Non --- Direct Vent (1 --- Pipe) Direct Vent (2 --- Pipe) Non --- Direct Vent (1 --- Pipe) Upflow 4,000 4,000 93,000 93,000 1,000,000 Downflow 4,000 4,000 93,000 93,000 1,000,000 Hizontal 4,000 4,000 93,000 93,000 1,000,000 Upflow 4,000 4,000 93,000 93,000 1,000 Downflow 4,000 4,000 93,000 93,000 1,000 Hizontal 4,000 4,000 93,000 93,000 1,000 Upflow Downflow Hizontal Upflow 90 Downflow 90 Hizontal 90 Certified Temperature Rise Range F Certified External Static Pressure Heating Cooling Heating Airflow CFM 1990/4 Cooling 192/3 1 19/21 00/21 ELECTRICAL Unit Volts Hertz Phase 11 1 Operating Voltage Range Min Max** 4 Maximum Unit Amps Unit Ampacity Minimum Wire Size Maximum Wire Length (Ft) Maximum Fuse Size Ckt Bkr Amps (Time---Delay Type Recommended) 1 1 Transfmer (24v) va External Control Heating va Power Available Cooling 21va Air Conditioning Blower Relay Standard CONTROLS Limit Control SPST Heating Blower Control (Off Delay) Selectable 90, 1, 10, 180 Burners (Monopt) Gas Connection Size 1/2 ---in. NPT GAS CONTROLS Manufacturer White --- Rodgers Minimum Inlet Pressure (In. W.C.) 4. (Natural Gas) Gas Valve (Redundant) Maximum Inlet Pressure 13.6 (Natural Gas) (In. W.C.) Ignition Device Hot Surface BLOWER DATA Direct---Drive Mot HP (Permanent Split Capacit) 1/2 3/4 1/2 3/4 3/4 3/4 Mot Full Load Amps RPM (Nominal) Speeds 4 Blower Wheel Diameter x Width (In.) 11 X 8 11 X 11 X 8 11 X 11 X 11 X Filter Size (In.) Permanent Washable (1) X 2 X 3/4 (1) 24 X 2 X 3/4 FACTORY---AUTHORIZED AND LISTED, DEALER---INSTALLED OPTIONS Gas Conversion Kit Natural --- to --- Propane KGANP41ALL Gas Conversion Kit Propane --- to --- Natural KGAPN3901ALL Twinning Kit KGATW01HSI N/A Manufactured (Mobile) Home Kit KGAMH01KIT N/A Downflow Base*** KGASB01ALL Vent Termination Kit (Bracket Only f 2 Pipes) 2---in. KGAVT01BRA 3---in. KGAVT01BRA Vent Termination Kit (Single Exit) 2---in. KGAVT01CVT 3---in. KGAVT0801CVT Condensate Freeze Protection Kit KGAHT01CFP Side Filter Rack (Without Filter) Upflow KGAFR06ALL Condensate Neutralizer Kit (obtained thru RCD) P Do Gasket Kit KGBAC01DGK * Gas input ratings are certified f elevations to 00 ft. F elevations above 00 ft, reduce ratings 2 percent f each 00 ft above sea level. In Canada, derate the unit percent from 00 to 0 ft above sea level. Capacity and AFUE in accdance with U.S. Government DOE test procedures. Airflow shown is f only return---air supply. F air delivery above 1800 CFM, see Air Delivery table f other options. A filter is required f each return---air supply. ** Permissible voltage limits f proper furnace operation. Unit ampacity = percent of full load amps of largest components plus 0 percent full load amps of all other potential operating components (EAC, humidifier, etc.). Length shown is measured 1 way along wire path between unit and service panel f maximum 2 percent voltage drop. *** Required f installation on combustible flos when no coil box is used, when any coil box other than a Payne CD, CK, CAP(R), CNP(R), KCAKC cased coil is used. F direct vent applications only. N/A--- Not Applicable. Unit is not allowed in this installation application. ICS--- Isolated Combustion System

6 MAXIMUM ALLOWABLE PIPE LENGTH - 0 to 00 (0 to 6) 01 to 00 (6 to 914) Canada 0,000 1, ,000 1,000 1 DIRECT VENT (2-PIPE) TERMITION 2Pipe3-in 1 (2) 1 (2) 2-1/2 (64) one 2-1/2 (64) 3 (6) 3 (6) no 3 (6) 2-1/2 (64) one 3 (6) 3 (6) no 4 (2) no DIRECT VENT (2-PIPE) TERMITION 2Pipe3-in 3 (6) 3 (6) 3 (6) no 4 (2) no 3 (6) one 4 (2) no 3 (6) no 4 (2) no (1.) (1.) (.2) 4 (13.) (1.) (.1) 1 6 (19.8) (1.) 0 (1.2) 3 (.) (.2) 3 (.) 2 (.6) 3 (.6) 6 (.0) 2 (1.8) 2 (.6) 1 (.2) (.4) (.2) 3 (.) 14 (4.3) 63 (19.2) 39 (11.8) (3.) 6 (.4) 26 (.9) 9 (2.) 1 3 (.6) (2.1) 66 (.1) 16 (4.9) 2 (1.8) 2 (1.8) 4 (14.3) 2 (.6) 16 (4.9) 2 (.6) 6 (1.8) 66 (.1) 1 63 (19.2) 31 (11.9) 6 (.1) (1.) 2 (8.2) 0 (1.2) 23 (.0) (13.1) 19 (.8) See notes at end of table. 6

7 MAXIMUM ALLOWABLE PIPE LENGTH - 01 to 00 (914 to 19) 01 to 000 (19 to 4) 0,000 1, ,000 1,000 1 DIRECT VENT (2-PIPE) TERMITION 2Pipe3-in 4 no --- IN (mm)* --- IN (mm)* 3 (6) no 3 (6) 4 (2) no 3 (6) one 4 (2) no 3 (6) no 4 (2) no DIRECT VENT (2-PIPE) TERMITION 2Pipe3-in 3 (6) no 3 (6) 4 (2) no 4 (2) no 3 (6) no 4 (2) no (19.) 16 (4.9) 68 (.) 46 (14.0) 33 (.1) 6 (19.8) 9 (18.0) 11 (3.4) 9 (18.0) 11 (3.4) 63 (19.2) 41 (.) 24 (.3) 8 (.) 9 (18.0) 6 (1.8) 26 (.9) 4 (16.) 6 (1.8) 28 (8.) 1 1 (1.) 8 (.) (13.1) 23 (.0) 14 (4.3) 66 (.1) 22 (6.) (1.) 38 (11.6) 6 (.1) 13 (4.0) 6 (.1) 31 (9.4) 6 (.1) 22 (6.) 18 (.) 14 (4.3) (19.) 31 (9.4) 3 6 (.1) 21 (6.4) 69 (21.0) 9 (18.0) 39 (11.9) 22 (6.) 46 (14.0) (.1) 64 (19.) 0 (1.2) (1.) 8 (.) 26 (.9) 13 (4.0) 6 (.4) (.2) 4 (16.) 13 (3.9) 9 (.9) 4 (13.) 39 (11.9) 3 21 (6.4) (3.) 33 (.1) 3 9 (2.) 4 (16.4) 2 (1.8) 26 (.9) 2 (1.8) (1.) (1.0) 2 (1.8) 11 (3.4) 2 (1.8) 2 (1.8) See notes at end of table.

8 MAXIMUM ALLOWABLE PIPE LENGTH to 00 (4 to 1829) 01 to 00 (1829 to 2134) 01 to 00 (1829 to 2134) 0,000 1, ,000 1,000 1 DIRECT VENT (2-PIPE) TERMITION 2Pipe3-in 3 (6) no 3 (6) 4 (2) no 4 (2) no 3 (6) no 4 (2) no DIRECT VENT (2-PIPE) TERMITION 2Pipe3-in 3 (6) no 3 (6) 4 (2) no 4 (2) no 4 (2) no (4.3) 41 (.) 29 (8.8) 42 (.8) 3 (3.6) 42 (.8) 2 (1.8) 9 (2.) 36 (11.0) 21 (6.4) 6 (.4) 3 (.) 2 (1.8) 8 (2.4) 3 (11.2) 4 (14.3) 42 (.8) (.2) 3 (.) 4 (16.) 23 (.0) (3.) 29 (8.8) 0 (1.2) 18 (.) 11 (3.4) 22 (6.) (.2) 2 (1.8) 1 4 (14.3) 8 (2.4) 4 (14.3) 9 (2.) 4 (14.3) 32 (9.) 2 (8.2) 22 (6.) (.1) (4.0) 38 (11.6) 2 (8.2) 68 (.) 31 (9.4) (.1) 8 (2.4) 2 (1.8) 33 (.1) 19 (.8) 63 (19.2) 24 (.3) (3.6) ( (.) 38 (11.6) 6 (.4) 3 (11.3) 66 (.1) 32 (9.8) 64 (19.) 0 (1.2) 21 (6.4) 68 (.) 8 (.) 18 (.) 4 (14.3) (2.1) 4 (13.) 16 (4.9) 6 (.4) 9 (2.) 3 11 (3.4) 4 (13.) 1 66 (.1) 6 (.4) (13.1) 6 (1.8) 64 (19.) (13.1) (13.1) (18.8) See notes at end of table. 8

9 MAXIMUM ALLOWABLE PIPE LENGTH - DIRECT VENT (2-PIPE) TERMITION (.1) 6 (19.8) 39 (11.9) 63 (19.2) 34 (.4) 33 (.1) 28 (6.) 9 (18.0) (3.) 3 (2.1) 46 (14.0) 41 (.) (.2) 38 (11.6) 01 to 8000 (2134 to 28) 0,000 2Pipe3-in 3 (6) no 36 (11.0) 66 (.1) 2 (.6) 63 (19.2) 31 (9.4) 6 (19.8) (.2) 8 (.) 13 (4.0) 19 (.8) 63 (19.2) 8 (2.4) 3 (2.1) 14 (4.3) (2.1) (3.) (13.1) 9 (18.0) 38 (11.6) 1,000 3 (6) 4 (2) no 4 (2) no 46 (14.0) 6 (.1) (13.1) 1 (1.) 41 (.) 46 (14.0) (.2) 41 (.) 38 (11.6) 36 (11.0) 1 DIRECT VENT (2-PIPE) TERMITION (14.0) 41 (.) 36 (11.0) 8 (.) 31 (9.4) 6 (.1) 29 (8.8) 24 (.3) 3 11 (3.4) 6 (1.8) 42 (.8) 3 (11.3) 3 (.) 34 (.4) 8001 to 9000 (28 to 2) 33 (.1) 28 (8.) (.2) 8 (.) (3.) 6 (.1) 3 0,000 2Pipe3-in 23 (.0) 9 (18.0) 1 4 (16.) (2.1) (1.) 39 (11.9) 34 (.4) 3 (6) no 1,000 3 (6) 4 (2) no 4 no (13.1) 3 (.) 41 (.) 39 (11.9) 2 (.6) 3 (11.3) 3 (.) 1 34 (.4) 1 See notes at end of table. 9

10 MAXIMUM ALLOWABLE PIPE LENGTH to,000 (2 to ) 0,000 1,000 DIRECT VENT (2-PIPE) TERMITION 2Pipe3-in 3 (6) 4 (2) no 4 (2) no (.8) 4 (13.) 21 (6.4) 4 (16.) 39 (11.9) 3 (11.3) (.2) 2 (.6) 13 (4.0) 3 (11.3) (1.) 32 (9.8) 3 38 (11.6) 14 (4.3) 3 (1.) 3 (.) 2 (8.2) 1 (1.) 33 (.1) 9 (2.) 1 (1.) 2 (.6) 31 (9.4) (2.1) 4 (14.3) 29 (8.8) 4 (14.3) 39 (11.9) 33 (.1) 34 (.4) 31 (9.4) 29 (8.8) 29 (8.8) * Disk usage-unless otherwise specified, use perfated assembly (facty-supplied in loose parts bag). # If one is stated, separate 2 halves of perfated assembly and use shouldered half. When using shouldered half, install screen side toward inlet box. Wide radius elbow. Vent sizing f Canadian installations over 0 ft. (132 M) above sea level are subject to acceptance by the local authities having jurisdiction. -Not Allowed; pressure switch will not make. 1. Do not use pipe size greater than those specified in table incomplete combustion, flame disturbance, flame sense lockout may occur. 2. Size both the combustion-air and vent pipe independently, then use the larger diameter f both pipes. 3. Assume two 4 elbows equal one 90 elbow. Wide radius elbows are desirable and may be required in some cases. 4. Elbows and pipe sections within the furnace casing and at the vent termination should not be included in vent length elbow count.. The minimum pipe length is ft (1. M) f all applications. 6. Use 3-in. (6 mm) diameter vent termination kit f installations requiring 4-in (2 mm) diameter pipe. VENT LENGTH FOR OUTLET RESTRICTOR USAGE ( BTU MODEL ) } ( ) ( )* ( ) ( ) ( ) ( ) ( ) ( ) (2 --- ) *Canada DIRECT VENT (2---PIPE). (IN / mm) NON --- DIRECT VENT (1---PIPE ). (IN / mm) in. (1) in. (1) in. (1) in. (1) in. (1) in. (1) in. (1) in. (1) in. (1) in. (1) in. (1) in. (1) in. (1) in. (1) in. (1) in. (1) in. (1) in. (1) NO. OF 90_ ELBOWS (8.) 24 (.3) 21 (6.4) (.1) 14 (4.2) (3) 6 (1.8) (6) (.1) 13 (3.9) (3) 6 (1.8) 1 (4.2) (3.6) 8 (2.4) (1.) (3) (2.1) }Discard outlet restrict if vent lengths elbows exceed the above table Discard restrict if using 11/2---in. (38mm) diameter pipe. Refer to installation instructions f outlet restrict installation guidelines.

11 COMBUSTION -AIR PIPE FOR NON -DIRECT VENT (1 -PIPE) APPLICATIONS (SIZES 0 THROUGH 1 ) FIELD-SUPPLIED 2-IN. (1 mm) DIA. PVC 90 ELBOW FIELD-SUPPLIED 2-IN. (1 mm) DIA. PVC PIPE A COMBUSTION-AIR DISC (FACTORY-SUPPLIED IN LOOSE PARTS BAG) CASING WIDTH IN (mm) A IN (mm) ---1/2 () 8-1/2 ± ½ (216 ± 13) 21 (33) -1/2 ± ½ (26 ± 13) /2 (2) ± ½ ( ± 13) A911 CONCENTRIC VENT FOR DIRECT -VENT (2 -PIPE) APPLICATION (ALL MODEL SIZES) B IN. (MM) DIA PVC VENT/EXHAUST F E 1 3 /16 ( mm) C IN. (MM) DIA 11/2 (38 mm) D A B IN. (MM) DIA PVC INTAKE/COMBUSTION AIR A91 PART NO. A* B C D{ E F KGAVT01CVT /8 (8) 2 (1) /2 (89) /8 (422) /4 (19) --- 3/4 (146) KGAVT0801CVT /8 (98) 3 (6) /2 (114) /8 (3) --- 3/8 (18) /2 (16) * Dimension A will change accdingly as dimension D is lengthened shtened. {Dimension D may be lengthened to in. (4 mm) maximum. Dimension D may also be shtened by cutting the pipes provided in the kit to in. ( mm) minimum. NOTE: See furnace Installation Instructions when venting multiple furnaces near each other. 11

12 SIDE FILTER RACK 1 1 / 4 (TYP) (32 mm) 3 / 1 8 ( mm) / 2 TABS (13 mm) 2 3 / 8 ( mm) 1 1 / 4 (32 mm) 2 1 / 8 (638 mm) 3 / 4 (19 mm) 1 / / 8 (8 mm) 16 1 / 8 (4 mm) ( mm) OPENING 14 1 /2 (368 mm) OPENING ACCESSORY DOWNFLOW SUBBASE A80199 LOCATING TAB 1 1 / 4-in. ( mm) TYP B PLENUM OPENING D A LOCATING TAB FACTORY-SUPPLIED FIELD-INSTALLED INSULATION C Disassembled A88 Assembled A942 FURCE CASING WIDTH IN (mm) FURCE IN DOWNFLOW APPLICATION PLENUM OPENING* IN (MM) A FLOOR OPENING IN (MM) B C D HOLE NO. FOR WIDTH ADJUSTMENT ---1/2 ( mm) 21 (33 mm) /2 (2 mm) Furnace with without Cased Coil Assembly Coil Box Furnace with without Cased Coil Assembly Coil Box Furnace with without Cased Coil Assembly Coil Box 1---1/8 (384 mm) 18---/8 (43 mm) /8 ( mm) 19 (3 mm) 19 (3 mm) 19 (3 mm) /4 (426 mm) ---1/4 (14 mm) /4 (3 mm) *The plenum should be constructed 1/4 in. (6 mm) smaller in width and depth than the plenum dimensions shown above. ---3/8 (18 mm) ---3/8 (18 mm) ---3/8 (18 mm) 3 2 1

13 CLEARANCE TO COMBUSTIBLES REV. B LIT TOP A08 13

14 AIR DELIVERY - CFM (WITH FILTER)* UNIT SIZE RETURN--- AIR SUPPLY both sides 1 side and both sides 1 side and only both sides 1 side and only only both sides 1 side and SPEED Med --- Med --- Med --- Med --- Med --- Med --- Med --- Med --- Med --- Med --- Med --- Med --- Med --- Med --- Med --- Med --- Med --- Med --- Med --- Med --- Med --- Med --- Med --- Med --- Med --- Med --- Med --- EXTERL STATIC PRESSURE (In. W.C.) only Med * A filter is required f each return---air supply. * F hizontal and downflow applications, use 1 side only as airflow reference

15 TYPICAL INSTALLATIONS OUTDOOR UNIT COMBUSTION AIR PIPE (DIRECT VENT/2-PIPE APPLICATION) A/C COIL VENT PIPE HUMIDIFIER COMBUSTION AIR INLET ( 1-PIPE APPLICATION) ELECTRONIC AIR CLEANER GAS-FIRED WATER HEATER AIRFLOW FRONT OF FURCE Basement - Upflow Application A0064 ELECTRONIC AIR CLEANER VENT COMBUSTION AIR INLET ( VENT/ 1-PIPE APPLICATION HUMIDIFIER COMBUSTION AIR (DIRECT VENT/ 2 PIPE APPLICATION OUTDOOR UNIT A/C COIL FRONT OF FURCE Closet - Downflow Application AIRFLOW A006 1

16 TYPICAL INSTALLATIONS (CONTINUED) COMBUSTION-AIR INLET ( VENT/1-PIPE APPLICATION) VENT PIPE COMBUSTION AIR PIPE DIRECT VENT/2-PIPE APPLICATION) ELECTRONIC AIR CLEANER FRONT OF FURCE FURCE CONDENSATE DRAIN AIRFLOW REFRIGERATION PIPING AIR CONDITIONING COIL Attic - Hizontal Application A0066 COMBUSTION - AIR INLET ( VENT/ 1-PIPE APPLICATION) COMBUSTION AIR PIPE (DIRECT VENT/2-PIPE APPLICATION) VENT PIPE REFRIGERATION PIPING AIR CONDITIONING COIL AIRFLOW FURCE CONDENSATE DRAIN FRONT OF FURCE ELECTRONIC AIR CLEANER Crawlspace - Hizontal Application A006 E Payne Heating & Cooling Systems D 3 W. Mris St. D Indianapolis, IN 1 Printed in U.S.A. Edition Date: 09/ Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No: SS Replaces: SS

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE MULTIPOISE CONDENSING GAS Product Data INSTALLATION FLEXIBILITY The 4 -way multipoise design allows a model to be installed in an upflow, downflow, hizontal ientation. All sizes of the may be installed

More information

Model PG9MAB MULTIPOISE CONDENSING GAS FURNACE SS-PG9MAB-01. Time Roman FEATURES. burners seldom, if ever, needs cleaning.

Model PG9MAB MULTIPOISE CONDENSING GAS FURNACE SS-PG9MAB-01. Time Roman FEATURES. burners seldom, if ever, needs cleaning. Time Roman INSTALLATION FLEXIBILITY: CASING: COMBUSTION SYSTEM: 3-PASS PRIMARY HEAT EXCHANGERS: FLOW-THROUGH SECONDARY HEAT EXCHANGERS: LIMITED WARRANTY: MONOPORT INSHOT BURNERS: The 4-way multipoise design

More information

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURCE Product Data A9801 Utilizing the extensive resources available to Payne, a new standard of excellence has been achieved with the model. The model is a unique

More information

350MAV HIGHLY-EFFICIENT 4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE. Sizes 040 thru 140 Series D. Form No. PDS 350M.40.

350MAV HIGHLY-EFFICIENT 4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE. Sizes 040 thru 140 Series D. Form No. PDS 350M.40. HIGHLY-EFFICIENT 4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE 350MAV Sizes 040 thru 140 Series D Utilizing the extensive resources available to Bryant, a new standard of excellence

More information

Product Data. 340AAV 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Sizes 040 thru 140

Product Data. 340AAV 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Sizes 040 thru 140 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Sizes 040 thru 140 Product Data A0086 The model Multipoise Condensing Furnace is specifically designed to meet the needs of the new construction market.

More information

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES SIZES AVAILABLE: 024045 through 060155 EFFICIENCY: The GB1AAV Induced-Combustion Gas Furnace provides the efficiency customers want with 80% Annual Fuel Utilization Efficiency (AFUE). IGNITION: The field-proven

More information

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 111 Input Capacities: 40,000 thru 120,000 Btuh Product Data 58MCA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 111 Input Capacities: 40,000 thru 120,000 Btuh High Efficiency and Flexibility Designed to Meet the Needs of New Homes The

More information

355MAV Sizes 040 thru 120 Series E

355MAV Sizes 040 thru 120 Series E DELUXE 4-WAY MULTIPOISE VARIABLE-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE 355MAV Sizes 040 thru 120 Series E HIGH EFFICIENCY GAS FURNACE VARIABLE CAPACITY SYSTEM THE INTELLIGENT ING MACHINE Building

More information

Product Data. 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh Product Data 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh *High Efficiency and Flexibility Designed to Meet the Needs of New Homes

More information

Product Data. 58MXA Deluxe 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58MXA Deluxe 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. Series 111 Input Capacities: 40,000 thru 120,000 Btuh HEATING & COOLING Product Data 58MXA Deluxe 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 111 Input Capacities: 40,000 thru 120,000 Btuh 4-way Multipoise Design Allows More Applications...

More information

Product Data. 58MEC PERFORMANCE BOOST WAY MULTIPOISE STAGE CONDENSING GAS FURNACE Input Rates: 60,000 thru 120,000 Btuh

Product Data. 58MEC PERFORMANCE BOOST WAY MULTIPOISE STAGE CONDENSING GAS FURNACE Input Rates: 60,000 thru 120,000 Btuh PERFORMANCE BOOST 90 4 --- WAY MULTIPOISE 2 --- STAGE CONDENSING GAS FURCE Input Rates: thru 1,000 Btuh Product Data 4 -WAY MULTIPOISE DESIGN ALLOWS MORE APPLICATIONS design, the secondary heat exchanger

More information

395CAV Sizes 045 thru 155 Series H and J

395CAV Sizes 045 thru 155 Series H and J ENERGY-EFFICIENT INDUCED-COMBUSTION DELUXE UPFLOW FURNACE 395CAV Sizes 045 thru 155 Series H and J With a unique approach to induced-combustion design, a 40-in. tall cabinet, 4-pass heat exchanger, an

More information

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE). This document was created with FrameMaker 4.0.4 SIZES AVAILABLE: 024065 through 060150 EFFICIENCY: IGNITION: HEAT EXCHANGER: CONTROL BOARD: The GA1A Induced-Combustion Gas Furnace provides the efficiency

More information

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace Series 131 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace Series 131 Input Capacities: 40,000 thru 120,000 Btuh Product Data 58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace Series 131 Input Capacities: 40,000 thru 120,000 Btuh Efficiency and Flexibility Designed to Meet the Needs of New

More information

Product Data. 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace. Series 121 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace. Series 121 Input Capacities: 40,000 thru 120,000 Btuh Product Data 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace Series 121 Input Capacities: 4, thru 12, Btuh U L T R A H I G H E F F I C I E N C Y G A S F U R N A N C E Variable capacity,

More information

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price Product Data 58PAV Energy-Efficient Induced-Combustion Upflow Furnace Input Capacities: 45,000 thru 155,000 Btuh 80% AFUE At Budget Price Carrier provides an 80 percent Annual Fuel Utilization Efficiency

More information

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall 310AAV/310JAV 4 -Way Multipoise Induced Combustion Gas Furnace Sizes 045 thru 155 Series E Product Data STANDARD FEATURES S Noise elimination combustion system S Four-position furnace: Upflow, Hizontal

More information

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa) 80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Series B approved for Twinning applications (0902116, 1002122, and 1352422) with accessory (order separately) Supports two stage cooling

More information

Cooling Capacity CFM range

Cooling Capacity CFM range R9MSB Product Specifications 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE all models in all positions California NOx approved Cabinet air leakage less than 2.0% at 1.0 in. W.C. and

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) R9MSB Product Specifications 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning

More information

58CTA/CTX PERFORMANCE 80 TWO --- STAGE WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140

58CTA/CTX PERFORMANCE 80 TWO --- STAGE WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140 PERFORMANCE 80 TWO --- STAGE 4 --- WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140 Product Data A10249 THE PERFORMANCE 80 GAS FURNACE The Two-Stage,

More information

Product Data. 58STA/STX 4-WAY MULTIPOISE INDUCED-COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh THE CARRIER 58STA/STX GAS FURNACE

Product Data. 58STA/STX 4-WAY MULTIPOISE INDUCED-COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh THE CARRIER 58STA/STX GAS FURNACE 4-WAY MULTIPOISE INDUCED-COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Product Data THE CARRIER GAS FURNACE The 4 -way Multipoise Gas Furnaces feature Carrier s QuieTecht noise reduction

More information

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace. Series 120 Input Capacities: 40,000 thru 135,000 Btuh

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace. Series 120 Input Capacities: 40,000 thru 135,000 Btuh Product Data 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace Series 120 Input Capacities: 40,000 thru 135,000 Btuh Comfort Heating for Energy-Efficient Gas Furnaces Carrier leads

More information

Wt. Lbs Model Number (BTUH) Hz

Wt. Lbs Model Number (BTUH) Hz Up to 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions F95% AFUE in downflow position California NOx approved Most models have earned the ENERGY STAR

More information

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input Product Data 58EFA Horizontal Gas Furnace 50,000 125,000 Btuh Input GAS SUPPLY MANUAL SHUTOFF VALVE SEDIMENT TRAP UNION Carrier presents the 58EFA, a dedicated horizontal gas furnace that excels in the

More information

Product Data. 58CTA/CTX PERFORMANCE 80 TWO-STAGE 4-WAY MULTIPOISE INDUCED-COMBUSTION FURNACE Input Capacities: 45,000 thru 155,000 Btuh

Product Data. 58CTA/CTX PERFORMANCE 80 TWO-STAGE 4-WAY MULTIPOISE INDUCED-COMBUSTION FURNACE Input Capacities: 45,000 thru 155,000 Btuh PERFORMANCE 80 TWO-STAGE 4-WAY MULTIPOISE INDUCED-COMBUSTION FURNACE Input Capacities: 45,000 thru 155,000 Btuh Product Data A04041 THE PERFORMANCE 80 GAS FURNACE The Two-Stage, 4-way Multipoise Gas Furnaces

More information

Product Data. Infinity 96 Model 58MVB Deluxe 4-Way Multipoise Variable-Speed Condensing Gas Furnace. Series 100 Input Rates: 40,000 thru 120,000 Btuh

Product Data. Infinity 96 Model 58MVB Deluxe 4-Way Multipoise Variable-Speed Condensing Gas Furnace. Series 100 Input Rates: 40,000 thru 120,000 Btuh Product Data Infinity 96 Model 58MVB Deluxe 4-Way Multipoise Variable-Speed Condensing Gas Furnace Series 100 Input Rates: 40,000 thru 120,000 Btuh A05069 Comfort Heat technology, the ultimate in heating

More information

Product Data. 58WAV WeatherMaker 8000 Energy-Efficient Deluxe Upflow Furnace. Series 150 and 160 Input Capacities: 45,000 thru 155,000 Btuh

Product Data. 58WAV WeatherMaker 8000 Energy-Efficient Deluxe Upflow Furnace. Series 150 and 160 Input Capacities: 45,000 thru 155,000 Btuh Product Data 58WAV WeatherMaker 8000 Energy-Efficient Deluxe Upflow Furnace Series 50 and 60 Input Capacities: 45,000 thru 55,000 Btuh Advanced Technology for Energy-Efficient Gas Furnaces Carrier leads

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 93% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 93% AFUE, all models all positions F9MES 50 Hz Product Specifications Certified to leak 2% or less of nominal air conditioning CFM delivered when

More information

Product Data. 59SP5A Performance Boost, Single---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

Product Data. 59SP5A Performance Boost, Single---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY* TM 59SP5A Performance Boost, Single---Stage 4 --- Way Multipoise Condensing Gas Furnace Series 100 Product Data A1126 The 59SP5A Multipoise Performance Boost Condensing Gas Furnace features SEER -boosting

More information

Product Data. 925SA PREFERREDt SERIES SINGLE -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES A LIMITED WARRANTY*

Product Data. 925SA PREFERREDt SERIES SINGLE -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES A LIMITED WARRANTY* 925SA PREFERREDt SERIES SINGLE -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES A A11264 The 925SA Multipoise SEER Boost Condensing Gas Furnace features the single -stage Preferred System. The multi

More information

PLUS 95st MODEL 355CAV DELUXE 4 -WAY MULTIPOISE VARIABLE -SPEED MULTI -STAGE CONDENSING GAS FURNACE Series 100 Input Rates: 60,000 thru 120,000 Btuh

PLUS 95st MODEL 355CAV DELUXE 4 -WAY MULTIPOISE VARIABLE -SPEED MULTI -STAGE CONDENSING GAS FURNACE Series 100 Input Rates: 60,000 thru 120,000 Btuh PLUS 95st MODEL DELUXE 4 -WAY MULTIPOISE VARIABLE -SPEED MULTI -STAGE CONDENSING GAS FURNACE Series 100 Input Rates: 60,000 thru 120,000 Btuh Product Data A05085 Building on our industry -leading family

More information

Product Data. 59TP5A Performance Boost Two---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

Product Data. 59TP5A Performance Boost Two---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY* TM 59TP5A Performance Boost Two---Stage 4 --- Way Multipoise Condensing Gas Furnace Series 100 Product Data A1126 The 59TP5A Two -stage Multipoise Performance Boost Condensing Gas Furnace features two

More information

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 160

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 160 4 --- WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 160 Product Data THE CARRIER GAS FURNACE The 4 -way Multipoise Gas Furnaces feature Carrier s QuieTecht

More information

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall 310AAV/310JAV 4 -Way Multipoise Induced Combustion Gas Furnace Sizes 045 thru 155 Series G Product Data STANDARD FEATURES S Noise elimination combustion system S Four-position furnace: Upflow, Horizontal

More information

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Deluxe Upflow Furnace

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Deluxe Upflow Furnace Product Data 58TUA WeatherMaker 8000TS with Comfort Heat Technology Deluxe Upflow Furnace Series 120 and 130 Input Capacities: 40,000 thru 135,000 Btuh Comfort Heating for Energy-Efficient Gas Furnaces

More information

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING DIRECT OR NON -DIRECT VENT 4-WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct Vent furnace S

More information

Product Data. 59TN6A InfinityR Two---Stage, Variable Speed Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

Product Data. 59TN6A InfinityR Two---Stage, Variable Speed Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY* 59TN6A InfinityR Two---Stage, Variable Speed 4 --- Way Multipoise Condensing Gas Furnace Series 100 Product Data A1126 The 59TN6A Multipoise Variable-Speed Condensing Gas Furnace features the two -stage

More information

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat 4-WAY MULTIPOISE INDUCED COMUBSTION GAS FURNACE INPUT CAPACITIES: 70,000 THRU 135,000 BTUH Product Data The gas furnace control system provides a dehumidification mode and a motor speed selection for continuous

More information

Product Data PG96VAT TWO -STAGE, 4 -WAY MULTIPOISE VARIABLE -SPEED CONDENSING GAS FURNACE

Product Data PG96VAT TWO -STAGE, 4 -WAY MULTIPOISE VARIABLE -SPEED CONDENSING GAS FURNACE TWO -STAGE, 4 -WAY MULTIPOISE VARIABLE -SPEED CONDENSING GAS FURNACE Product Data A11300 The two -stage gas valve is at the heart of the comfort provided by this furnace, along with the variable -speed

More information

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140, 150

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140, 150 4 --- WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140, 150 Product Data THE CARRIER GAS FURNACE The 4 -way Multipoise Gas Furnaces feature Carrier

More information

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation Product Data 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces 58BLA Low-Boy AN INDEPENDENT LABORATORY TESTING FOR PUBLIC SAFETY ama 58BMA 3-Way Multipoise 58BTA Upflow/Horizontal Copyright 1996 Carrier Corporation

More information

TSTAT0201CW Recommended (sold separately)

TSTAT0201CW Recommended (sold separately) G9MVE QuietComfort ET 96 Product Specifications Up to 96% AFUE, Communicating, Two Stage Gas Furnace EASIER TO SELL Up to 96% AFUE, all models, all positions California NOx approved Series A2 (or greater)

More information

Product Data A {Jurisdictions where warranty benefits cannot be conditioned on registration

Product Data A {Jurisdictions where warranty benefits cannot be conditioned on registration TWO -STAGE, 4 -WAY MULTIPOISE VARIABLE -SPEED CONDENSING GAS FURNACE Product Data A11300 The two -stage gas valve is at the heart of the comfort provided by this furnace, along with the variable -speed

More information

Product Data. Comfort Heatt technology, the ultimate in heating comfort...

Product Data. Comfort Heatt technology, the ultimate in heating comfort... INFINITY 96 DELUXE 4 --- WAY MULTIPOISE VARIABLE --- SPEED TWO---STAGE CONDENSING GAS FURNACE Series 120 Input Rates: 40,000 thru 120,000 Btuh Product Data A05069 Comfort Heatt technology, the ultimate

More information

Product Data 987MA EVOLUTIONR MODULATING 4 -WAY MULTIPOSE, VARIABLE SPEED CONDENSING GAS FURNACE, SERIES A LIMITED WARRANTY*

Product Data 987MA EVOLUTIONR MODULATING 4 -WAY MULTIPOSE, VARIABLE SPEED CONDENSING GAS FURNACE, SERIES A LIMITED WARRANTY* 987MA EVOLUTIONR MODULATING 4 -WAY MULTIPOSE, VARIABLE SPEED CONDENSING GAS FURNACE, SERIES A A11264 The 987MA Multipoise Variable-Speed Condensing Gas Furnace features the modulating EvolutionR System.

More information

Product Data PG95XAT CONDENSING GAS FURNACE SERIES B STANDARD FEATURES

Product Data PG95XAT CONDENSING GAS FURNACE SERIES B STANDARD FEATURES CONDENSING GAS FURNACE SERIES B Product Data. The model is a unique 4 -way multipoise condensing furnace with features like no other product in its class including two heating stages and an efficient ECM

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in

More information

CONDENSING GAS FURNACE

CONDENSING GAS FURNACE 4-WAY MULTIPOISE FIXED-CAPACITY NON-DIRECT-VENT CONDENSING GAS FURNACE 345MAV Sizes 040 thru 120 Combustion System Enclosed burner assembly isolates operating noise without the expense of sound deadening

More information

350MAV HIGHLY-EFFICIENT 4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT DELUXE CONDENSING GAS FURNACE. Sizes 040 thru 140. Form No. PDS 350M.40.

350MAV HIGHLY-EFFICIENT 4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT DELUXE CONDENSING GAS FURNACE. Sizes 040 thru 140. Form No. PDS 350M.40. HIGHLY-EFFICIENT 4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT DELUXE CONDENSING GAS FURNACE 350MAV Sizes 040 thru 140 Utilizing the extensive resources available to Bryant, a new standard of excellence

More information

Product Data. 59MN7A Infinityr Modulating Way Multipoise Condensing Gas Furnace Series 100

Product Data. 59MN7A Infinityr Modulating Way Multipoise Condensing Gas Furnace Series 100 59MN7A Infinityr Modulating 4 --- Way Multipoise Condensing Gas Furnace Series 100 Product Data A1126 The 59MN7A Multipoise Variable-Capacity Condensing Gas Furnace features the modulating InfinityR System.

More information

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa) 96% AFUE, Two Stage, Variable Speed Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER variable speed ECM blower motor Supports two stage cooling units

More information

RG7D 1-Stage Heat Series

RG7D 1-Stage Heat Series TECHNICAL SPECIFICATIONS RG7D 1-Stage Heat Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace

More information

Product Data. S HYBRID HEAT Dual Fuel System compatible S All models are chimney friendly when used with accessory vent kit

Product Data. S HYBRID HEAT Dual Fuel System compatible S All models are chimney friendly when used with accessory vent kit /PHY PERFORMANCE BOOST 80 4 --- WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 135,000 Btuh Series 100 Product Data multipoise design, through -the-furnace downflow venting,

More information

Product Data. S QuieTecht noise reduction system. S SmartEvapt -Humidity control when using a Thermidistat Control

Product Data. S QuieTecht noise reduction system. S SmartEvapt -Humidity control when using a Thermidistat Control COMFORT 80 DELUXE 4---WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 150 Product Data STANDARD FEATURES S QuieTecht noise reduction system S SmartEvapt

More information

TSTAT0101SC Recommended (order separately)

TSTAT0101SC Recommended (order separately) Up to 98% AFUE Communicating, Modulating Gas Furnace EASIER TO SELL 98% AFUE on G9MAC0602120, all positions 97% AFUE, all other models, all positions All Models have earned the ENERGY STAR Modulating heating

More information

Product Data. 59SC2A Comfort Series Single---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

Product Data. 59SC2A Comfort Series Single---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY* Comfort Series Single---Stage 4 --- Way Multipoise Condensing Gas Furnace Series 100 Product Data A11263 The 59SC2 Multipoise Comfort Series Condensing Gas Furnace features energy efficiency of 92.1% AFUE

More information

Product Data. 350AAV Highly-Efficient 4-Way Multipoise Fixed-Capacity Deluxe Condensing Gas Furnace Sizes 040 thru 140

Product Data. 350AAV Highly-Efficient 4-Way Multipoise Fixed-Capacity Deluxe Condensing Gas Furnace Sizes 040 thru 140 ly-efficient 4-Way Multipoise Fixed-Capacity Deluxe Condensing Gas Furnace Sizes 040 thru 140 Product Data A05085 Utilizing the extensive resources available to Bryant, a new standard of excellence has

More information

Gas Furnaces. Gas Furnaces. 2-Stage Variable-Speed. 2-Stage Multi-Speed Multipoise. Multipoise 80AFUE. 2-Stage Variable-Speed Multi-Speed Multipoise

Gas Furnaces. Gas Furnaces. 2-Stage Variable-Speed. 2-Stage Multi-Speed Multipoise. Multipoise 80AFUE. 2-Stage Variable-Speed Multi-Speed Multipoise % 96AFUE 2-Stage Variable-Speed % 95AFUE 2-Stage Multi-Speed Multipoise % 92AFUE Multipoise % AFUE 2-Stage Variable-Speed Multi-Speed Multipoise 86 87 96 % AFUE 2-Stage, Variable-Speed Up to 96 AFUE Variable-speed

More information

340AAV 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. Sizes 040 thru 140 FEATURES

340AAV 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. Sizes 040 thru 140 FEATURES 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Sizes 040 thru 140 Product Data combustion products to a point (typically below 115 F) that any of the approved types of pipe can also be used f venting

More information

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 95%+ AFUE Input 45,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

Product Data. 59TP6A Performance Two-Stage, Variable Speed 4-Way Multipoise Condensing Gas Furnace Series 2, 3

Product Data. 59TP6A Performance Two-Stage, Variable Speed 4-Way Multipoise Condensing Gas Furnace Series 2, 3 TM Performance Two-Stage, Variable Speed 4-Way Multipoise Condensing Gas Furnace Series 2, Product Data A1126 The Multipoise Variable Speed Condensing Gas Furnace features the two stage Performance System.

More information

Product Data STANDARD FEATURES

Product Data STANDARD FEATURES PERFORMANCE 80 TWO---STAGE VARIABLE --- SPEED 4 --- WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 135,000 Btuh Series 100 Product Data A10249 THE PERFORMANCE 80 GAS FURNACE

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PGF1TE 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 95.1 AFUE Direct Vent or Non Direct Vent Condensing Furnace 10 YEAR WARRANTY WORRY-FREE PERFORMANCE

More information

Multi-Position Gas Furnaces

Multi-Position Gas Furnaces MODEL: Multi-Position Gas Furnaces FORM NO. GSC-552 Rev. 1 Sure Comfort 92% A.F.U.E. Multi-Position Gas Furnaces Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] 92% residential gas furnace

More information

Product Data. IdealComfortt technology, the ultimate in heating comfort...

Product Data. IdealComfortt technology, the ultimate in heating comfort... INFINITYt ICS MODEL DELUXE 4 --- WAY MULTIPOISE VARIABLE --- SPEED MULTI---STAGE CONDENSING GAS FURNACE Series 100, Input Rates: 60,000 thru 120,000 Btuh Product Data A05069 IdealComfortt technology, the

More information

Product Data OBM/OVM. MULTIPOISE OIL FURNACE INPUT CAPACITIES 70,000 thru 154,000 BTUH THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data OBM/OVM. MULTIPOISE OIL FURNACE INPUT CAPACITIES 70,000 thru 154,000 BTUH THE LATEST IN OIL FURNACE TECHNOLOGY MULTIPOISE OIL FURNACE INPUT CAPACITIES 70,000 thru 154,000 BTUH Product Data THE LATEST IN OIL FURNACE TECHNOLOGY A10311 The models OBM and OVM combine high efficiency and quiet operation with oil heating

More information

Product Data. 925TA PREFERREDt SERIES TWO -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES B

Product Data. 925TA PREFERREDt SERIES TWO -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES B PREFERREDt SERIES TWO -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES B A11264 The Multipoise SEER Boost Condensing Gas Furnace features two -stage heating. The Perfect HeatR technology two -stage

More information

Product Data. 59SP5A Performance Boost, Single---Stage Way Multipoise Condensing Gas Furnace Series 100

Product Data. 59SP5A Performance Boost, Single---Stage Way Multipoise Condensing Gas Furnace Series 100 TM Performance Boost, Single---Stage 4 --- Way Multipoise Condensing Gas Furnace Series 100 Product Data A1126 The Multipoise Performance Boost Condensing Gas Furnace features SEER -boosting year-round

More information

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS KG6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency

More information

Product Data. 58CMA Multipoise Oil Furnace. Series 120 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. 58CMA Multipoise Oil Furnace. Series 120 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology Product Data 58CMA Multipoise Oil Furnace Series 120 Input Capacities: 70,000 thru 154,000 Btuh The Latest in Oil Furnace Technology The model 58CMA combines high efficiency and quiet operation with the

More information

Product Data. 925SA PREFERREDt SERIES SINGLE -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES A AND B. Select Models

Product Data. 925SA PREFERREDt SERIES SINGLE -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES A AND B. Select Models PREFERREDt SERIES SINGLE -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES A AND B Product Data A11264 The Multipoise SEER Boost Condensing Gas Furnace features the single -stage Preferred System.

More information

Product Data. 925SA PREFERREDt SERIES SINGLE -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES A. Select Models

Product Data. 925SA PREFERREDt SERIES SINGLE -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES A. Select Models PREFERREDt SERIES SINGLE -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES A Product Data A11264 The Multipoise SEER Boost Condensing Gas Furnace features the single -stage Preferred System. The Boost

More information

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. ) FORM NO. G66-536 REV. 5 Supersedes Form No. G66-536 Rev. 3 W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (92% A.F.U.E. ) MULTI POSITION GAS FURNACES Features 92% residential

More information

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. ) FORM NO. GTZ-539 REV. 2 Supersedes Form No. GTZ-503 Rev. 1 SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 96% A.F.U.E. ) TWO STAGE MULTI POSITION GAS FURNACES Features

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1RA Series M1010 Product Line High Efficiency / Upflow / Horizontal Gas Furnace Induced Draft - 80+ AFUEurnace 2 10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY

More information

Ruud Achiever Series Multi position Gas Furnaces

Ruud Achiever Series Multi position Gas Furnaces Gas Furnaces Ruud Achiever Series Multi position Gas Furnaces R92P- Series 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Rheem Classic Series Multi-position Gas Furnaces

Rheem Classic Series Multi-position Gas Furnaces Gas Furnaces Rheem Classic Series Multi-position Gas Furnaces R95P- Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

MULTI POSITION GAS FURNACE

MULTI POSITION GAS FURNACE FORM NO. GFJ-552 MULTI POSITION GAS FURNACE 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] Features 92% residential gas furnace CSA certified 4 way multi-poise design 7-Segment LED all

More information

MULTI POSITION GAS FURNACE

MULTI POSITION GAS FURNACE FORM NO. GFJ-537 MULTI POSITION GAS FURNACE FF***PS95 Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] Features 95% residential gas furnace CSA certified 4 way multi-poise design

More information

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES 036-1354-001 Rev. D (110) Heating TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE NATURAL GAS 37-111 MBH OUTPUT Air Conditioning EFFICIENCY RATING

More information

Product Data. S ECM Blower Motor included S QuieTecht noise reduction system S SmartEvapt Humidity control when using a Thermidistatt Control

Product Data. S ECM Blower Motor included S QuieTecht noise reduction system S SmartEvapt Humidity control when using a Thermidistatt Control /PH PERFORMANCE BOOST 80 4 --- WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 135,000 Btuh Series 110/120 Product Data /PH furnaces are approved for use with natural or propane

More information

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces Gas Furnaces Rheem Classic Plus Series Two Stage Multi position Gas Furnaces R96P- Series 96% A.F.U.E. * Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] A.F.U.E. (Annual Fuel Utilization Efficiency)

More information

Product Data. 59SP5A Performance Boost, Single---Stage Way Multipoise Condensing Gas Furnace Series 2

Product Data. 59SP5A Performance Boost, Single---Stage Way Multipoise Condensing Gas Furnace Series 2 TM Performance Boost, Single---Stage 4 --- Way Multipoise Condensing Gas Furnace Series 2 Product Data A1126 The Multipoise Performance Boost Condensing Gas Furnace features SEER -boosting year-round electrical

More information

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS KG6TE Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 95.1 Upflow/Horizontal The high effi ciency 2-Stage gas furnace

More information

Product Data. 58CMA Multipoise Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. 58CMA Multipoise Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology Product Data 58CMA Multipoise Oil Furnace Series 110 Input Capacities: 70,000 thru 154,000 Btuh The Latest in Oil Furnace Technology The model 58CMA combines high efficiency and quiet operation with the

More information

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3 FORM NO. G66-538 REV. 4 Supersedes Form No. G66-536 Rev. 3 W95T- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] MULTI-POSITION GAS FURNACES Features 95% residential gas furnace

More information

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. ) FORM NO. GTZ-538 Supersedes Form No. GTZ-503 Rev. 1 TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 95% A.F.U.E. ) 95% A.F.U.E. MULTI POSITION GAS FURNACES Features

More information

G6RC Series TECHNICAL SPECIFICATIONS

G6RC Series TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS G6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency upfl

More information

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XL 95 TUH2B060A936VA, TUH2B080A92VA, TUH2C100A98VA, TUH2D1A960VA, TDH2B060A936VA, TDH2B080A92VA, TDH2C100A98VA, TDH2D1A960VA

More information

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS FG6T(C,L) Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 92+ Upflow/Horizontal 90+ Downflow The high effi ciency 2-Stage

More information

Ruud Achiever Plus Series Multi-position Gas Furnaces

Ruud Achiever Plus Series Multi-position Gas Furnaces Gas Furnaces Ruud Achiever Plus Series Multi-position Gas Furnaces R92T- Series 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

Product Data. 59SP2A Performance Boost, Single---Stage Way Multipoise Condensing Gas Furnace Series 100

Product Data. 59SP2A Performance Boost, Single---Stage Way Multipoise Condensing Gas Furnace Series 100 TM Performance Boost, Single---Stage 4 --- Way Multipoise Condensing Gas Furnace Series 100 Product Data A1126 The Multipoise Performance Boost Condensing Gas Furnace features SEER -boosting year-round

More information

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology Product Data 58CLA Low-Boy Oil Furnace Series 110 Input Capacities: 70,000 thru 154,000 Btuh The Latest in Oil Furnace Technology The model 58CLA combines high efficiency and quiet operation with oil heating

More information

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33. Gas Furnaces Ruud Achiever Plus Series Two- Stage Multi-position Gas Furnaces - Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

Product Data. 58GFA High-Efficiency Induced-Combustion Upflow Furnace. Heating Inputs: 65, ,000 Btuh

Product Data. 58GFA High-Efficiency Induced-Combustion Upflow Furnace. Heating Inputs: 65, ,000 Btuh HETING & COOLING Product Data 58GF High-Efficiency Induced-Combustion Upflow Furnace Heating Inputs: 65,000 150,000 Btuh 78% FUE With Continuous- Pilot Ignition Carrier is the first manufacturer to provide

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1TA 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 80+ Upflow/Horizontal 2 Stage Gas Furnace with Variable Speed Blower 2 10 YEAR WARRANTY WORRY-FREE

More information

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. ) FORM NO. GTZ-540 Supersedes Form No. GTZ-503 Rev. 1 TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] (All Models 95% A.F.U.E. ) TWO STAGE VARIABLE SPEED MULTI POSITION GAS

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGC2T (C and L) Series SmartStart M1200 Product Line Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces 95.1 AFUE Input 60,000-120,000

More information

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90 TUX060, 080, 100, 120R TDX060, 080, 100, 120R Direct Vent with Variable Speed Inducer PUB. NO. 22-1705-02-1202

More information