Hot Food Holding Cabinets Test for FWE HLC

Size: px
Start display at page:

Download "Hot Food Holding Cabinets Test for FWE HLC"

Transcription

1 Design & Engineering Services Hot Food Holding Cabinets Test for Report Prepared by: Design & Engineering Services Customer Service Business Unit Southern California Edison January 4, 2011

2 Acknowledgements Southern California Edison s Design & Engineering Services (DES) group is responsible for this project. It was developed as part of Southern California Edison s Emerging Technology program under internal project number ET10SCE DES project manager Neha Arora conducted this technology evaluation with overall guidance and management from Juan Menendez and Paul Delaney. For more information on this project, contact neha.arora@sce.com. Disclaimer This report was prepared by Southern California Edison (SCE) and funded by California utility customers under the auspices of the California Public Utilities Commission. Reproduction or distribution of the whole or any part of the contents of this document without the express written permission of SCE is prohibited. This work was performed with reasonable care and in accordance with professional standards. However, neither SCE nor any entity performing the work pursuant to SCE s authority make any warranty or representation, expressed, or implied, with regard to this report, the merchantability or fitness for a particular purpose of the results of the work, or any analyses, or conclusions contained in this report. The results reflected in the work are generally representative of operating conditions; however, the results in any other situation may vary depending upon particular operating conditions. Southern California Edison Page ii

3 ABBREVIATIONS AND ACRONYMS ASTM BTU CFM CT DAS F ft FTC in kw kwh lb NEMA SCE VAR American Society for Testing and Materials British Thermal Unit Cubic Feet Per Minute Current Transformers Data Acquisition System Fahrenheit Feet Foodservice Technology Center Inches Kilowatt Kilowatt Hour Pound National Electrical Manufacturers Association Southern California Edison Volt-Ampere Reactive Southern California Edison Page i

4 FIGURES Figure 1. FWE HOT Food Holding Cabinet... 3 Figure 2. DAS Interface With National Instruments LabVIEW... 5 Figure 3. Cavity Thermocouple Installation... 7 Figure 4. Preheat Characteristics... 8 TABLES Table 1. Summary of FWE TST-16-EPL Hot Food Holding Cabinets... 1 Table 2. Energy Input Rate... 8 Table 3. Preheat and Idle Energy Rate... 9 EQUATIONS EQUATION 1. ENERGY INPUT RATE... 6 Equation 2. Energy Consumption (Idle Energy Rate)... 6 Southern California Edison Page ii

5 CONTENTS EXECUTIVE SUMMARY 1 INTRODUCTION 2 Background... 2 Objective... 2 Appliance Evaluated... 3 TEST METHODOLOGY 4 Laboratory and Instrumentation Description... 4 Thermostat Calibration... 5 Energy Input Rate... 6 Preheat and Idle Energy Rate... 6 RESULTS 7 Thermostat Calibration... 7 Figure 3. Cavity Thermocouple Installation... 7 Energy Input Rate... 7 Preheat and Idle Energy Rate... 8 CONCLUSION 10 APPENDIX A 11 REFERENCES 13 Southern California Edison Page iii

6 EXECUTIVE SUMMARY The hot food holding cabinet is widely used and is a versatile piece of equipment generally used in commercial kitchens. These cabinets are mostly used to; keep food at a safe serving temperature; keep serving plates warm, and to transport food for catering events. In addition, these hot food holding cabinets are lightweight for easy moving, yet strong enough for everyday use. These cabinets can be plugged into any wall outlet and sit on large wheels for easy mobility. The insulated cabinet utilizes magnetic door gaskets, auto door closers etc that provides additional energy saving attributes to these cabinets. This project assesses the energy efficiency level of the FWE model number HLC EPL hot food holding cabinet to determine an appliance baseline and a minimum energy efficiency level in order to qualify for the food service qualifying product list. This project also assesses the energy input rate, amount of energy consumed during holding cabinet preheating and idle energy rate. This test method was based on the reapproved version of ASTM F (revised July 23, 2010) Standard Test Method for Performance of Hot Food Holding Cabinets. Testing was performed at the Southern California Edison (SCE) Foodservice Technology Center (FTC) in Irwindale, CA. The test data provides key information to help determine the operation costs and the percentage of total kitchen productivity a single appliance can deliver. Testing for the idle energy rate or energy consumption began after preheating the cabinet and stabilized at 150 Fahrenheit (F) for two hours after inserting sheet pans at a predetermined position in the cabinet. The preheat test is the measure of energy consumed by the equipment in order to reach a temperature of 150 F, from a room temperature of 75 ± 2.5 F. The idle energy test reports the energy required to maintain a 150 F setpoint for a period of three hours or ten thermal cycles (whichever is longer). Idle energy consumption can be used to calculate real-world energy usage of the equipment. Table 1 presents a summary of the test results. TABLE 1. SUMMARY OF FWE HLC EPL HOT FOOD HOLDING CABINETS HOLDING CABINET RESULTS Nameplate Power (kw) 1.05 kw Measured Power (kw) 1.04 kw Percent Difference (%) 1.2% Preheat Time (min.) 9.03 min Preheat Energy (kwh) kwh Preheat Rate ( F/min) 8.51 F/min Idle Energy Rate (kw) 0.10 kw Idle Duty Cycle (%) 9.52 % Interior Volume (ft 3 ) 5.44 ft 3 Idle Volume Efficiency (W/ft 3 ) W/ft 3 Southern California Edison Page 1

7 INTRODUCTION The hot food holding cabinet is widely used and is a versatile piece of equipment generally used in commercial kitchens. These cabinets are mostly used to; keep food at a safe serving temperature; keep serving plates warm, and to transport food for catering events. In addition, these hot food-holding cabinets are lightweight for easy mobility, yet strong enough for everyday use. These cabinets can be plugged into any wall outlet and use large wheels for easy mobility. The insulated cabinet uses magnetic door gaskets, and auto door closers that provide additional energy saving attributes. This project assesses the energy input rate, amount of energy consumed during hot food holding cabinet preheating and idle energy rate. These parameters provide real world performance, providing end users with valuable information for purchasing and operating the hot food holding cabinets. BACKGROUND Southern California Edison (SCE) is committed to the advancement of the food service industry and is part of a statewide team offering a food service qualifying product list. The qualifying product list identifies the most efficient commercial kitchen appliances within a specific appliance category. The qualifying appliances are eligible to receive incentives for their use. Currently, hot food holding cabinets are not listed in any of the appliance categories on the food service qualifying list. OBJECTIVE This project examines the operation and performance of the FWE hot food holding cabinets. The operation and performance of the holding cabinet is evaluated using the American Society for Testing and Materials (ASTM) standard test methods. The intent of this project is to accurately record and represent the energy consumption of these cabinets for long and short-term thermal cycles. The testing examines the: Energy Input Rate: The peak rate at which a hot food holding cabinet consumes energy, kilowatt (kw). Preheat Energy: The amount of energy consumed, kilowatt hours (kwh), by the hot food holding cabinets while preheating its cavity from the ambient temperature to the specified thermostat setpoint, with the controls calibrated to the setpoint. Preheat Rate: The average rate at which the holding cabinet s cavity is heated from the room temperature to the predefined setpoint. Preheat Time: Time required by the cabinet to preheat from the room temperature to the predefined setpoint. Idle Energy Rate: The rate of energy consumed (kw) by the cabinets when empty that is required to maintain its cavity temperature at a specified thermostat setpoint. Southern California Edison Page 2

8 APPLIANCE EVALUATED Figure 1 shows the hot food holding cabinet. It is comprised of heliarc welded, single unit, 20-gauge polished exterior stainless steel walls with 22- gauge stainless steel interior. The holding cabinet has a radiant heat system that includes an incoloy nickel-chromium alloy heating element. The holding cabinet has a maximum holding temperature of 190 Fahrenheit (F). The interior has a nominal depth of 28 (inches), a nominal width of 21.0 and a nominal height of The chamber doors are flush mounted, double pan, stainless steel doors that has 1 thick fiberglass insulation. The temperature control have temperature scale marked in ten degree increments from 90 o F to 190 o F, an operational range thermometer, power supply light and a thermostat cycling light. The FWE holding cabinet has a rated electrical input rate of 1.05 kw. Appliance specifications and the manufacturer's literature are included in Appendix A. FIGURE 1. FWE HOT FOOD HOLDING CABINET Southern California Edison Page 3

9 TEST METHODOLOGY Laboratory testing of the FWE hot food holding cabinet was performed according to the ASTM F (Reapproved 2007)- Revised July 23, 2010 test method for hot food holding cabinets. 1 The test data provides key information to determine: Energy input rate Preheat energy Preheat rate and time Idle energy rate LABORATORY AND INSTRUMENTATION DESCRIPTION Testing was performed at the SCE Foodservice Technology Center (FTC). The FTC is a 2,000 square-foot demonstration and equipment test center. The center is a part of the Customer Technology Application Center, located in Irwindale, CA. It is a certified ASTM and ENERGY STAR testing laboratory. The FTC is capable of maintaining voltage regulation to ± 1 volt (V) on a V 3phase 4 Wire(W) system as well as a V split single phase, single and three-phase system. Receptacle configurations range from National Electrical Manufacturers Association (NEMA)-20R (20 amperes (A)/120V single-phase) to NEMA 4X and NEMA configuration FB11 (100A/208V/240V single-and three-phase) Receptacle. The FTC is also equipped with a Data Acquisition System (DAS), a National Instruments LabVIEW-based software pictured in Figure 2 used to monitor power (kw), amperage, voltage, power factor, frequency, and volt-ampere reactive (VAR) from all receptacles and display the results in a real-time graph during testing. The electrical consumption of the holding cabinet is logged in intervals of 1 second and the temperature data from 3 thermocouples is recorded. The interface also allows the user to configure the monitoring parameters and select specific monitoring hardware. Southern California Edison Page 4

10 FIGURE 2. DAS INTERFACE WITH NATIONAL INSTRUMENTS LABVIEW The DAS system is equipped with multi-functional digital transducers integrated serial current transformers (CTs) and voltage leads. The multi-functional digital transducer Data Stream RS485 detects power readings using CT and voltage inputs and has an accuracy of ± 0.5% over the full-scale readings. The CTs used in this project are accurate to 10% FS or better and have a frequency response ranging from 44 Hz to 3000 khz. DAS system uses Omega K type thermocouples and connectors. The K type thermocouples can read a temperature range of -328 F to 2,282 F with accuracy of ± 2.2 F or 0.75% of temperature reading above 32 F and 2% of temperature reading below 32 F. A fiberglass insulated 24- gage K type thermocouple was used to determine the cavity temperature of the holding cabinet. The DAS system was calibrated in November THERMOSTAT CALIBRATION Thermostat calibration is verified by installing a thermocouple in the geometric center of the cavity. Calibration is necessary since the placement of holding cabinet cavity temperature sensors can differ greatly between varying models and manufacturers. When performing a thermostat calibration, the holding cabinet stabilizes for one hour before taking readings of the cavity thermocouple. After the one-hour idle period, cavity temperatures are recorded at 30-second intervals for a minimum of 60 minutes. If the thermocouple reads an average temperature of 150 ± 5 F for a 60-minute period, then the thermostat is considered calibrated. Southern California Edison Page 5

11 ENERGY INPUT RATE The energy input rate is used to confirm proper operation of the hot food holding cabinets and to ensure that all test results are determined at the same temperature. The energy input rate is the peak energy consumption of the cabinet while preheating the cabinet cavity from ambient temperature to a setpoint of 150 F. The peak energy consumption must be operating within 5% of the nameplate energy input rate. Energy input rate is calculated using EQUATION 1. EQUATION 1. ENERGY INPUT RATE q input E 60 Model E35 t Where: q input = measured peak energy input rate, (kw) E = energy consumed during period of peak energy input, (kwh) t = period of peak energy input, (min.) PREHEAT AND IDLE ENERGY RATE The preheat test records the required amount of time and energy needed to raise the holding cabinet cavity temperature from ambient to a safe serving temperature. In this test, the holding cabinet was considered to at a safe serving temperature when the cavity reached 150 F. Once the cavity reached its setpoint of 150 F, it stabilizes for a period of two hours. After stabilization, the idle energy rate was taken by monitoring the consumption of the holding cabinet for a 3-hour period or ten thermal cycles (whichever is longer). The idle energy rate is the holding cabinets required rate of energy consumption (kw), when empty, needed to maintain its cavity temperature at a specified thermostat setpoint. The formula in EQUATION 2 calculates the idle energy rate. Equation 2. Energy Consumption (Idle Energy Rate) q idle E 60 t Where: q idle = energy consumption (idle energy rate), (kw) E = energy consumed during the test period, (kwh) t = test period (min.) Southern California Edison Page 6

12 RESULTS THERMOSTAT CALIBRATION The thermostat calibration reading was verified by installing a thermocouple in the geometric center of the cavity, as shown in FIGURE 3. While performing thermostat calibration, the holding cabinet was allowed to stabilize for 60 minutes before a onehour average reading of the cavity thermocouple was taken. Data was recorded for one-hour, sampled every 30 seconds, and the resultant average temperature was F. Because this result is within 5 F of 150 F, the cabinet s thermostat was deemed properly calibrated. Figure 3. Cavity Thermocouple Installation ENERGY INPUT RATE The input rates were always checked to be within ± 5% of the manufacturers specifications before any tests were taken on any given day. TABLE 2 lists the results of the input rate, taken on each of the individual test days, and are calculated using EQUATION 1. Southern California Edison Page 7

13 Table 2. Energy Input Rate Holding Cabinet Nameplate kw Measured kw Results 1.05 kw 1.04 kw Percent Difference (%) 1.2% PREHEAT AND IDLE ENERGY RATE The holding cabinet was preheated from room temperature at the thermostat calibration temperature of 150 F. The cavity reached 150 F after 9.03 minutes while the cabinet consumed kwh. The holding cabinet s preheat curve is shown in FIGURE 4. The preheat curve shows that the heating elements never turned off or cycled while heating to the cavity setpoint. Preheat Curve Temperature ( F) Time (min) Figure 4. Preheat Characteristics Southern California Edison Page 8

14 The holding cabinet was stabilized for two hours following the preheat test and then the energy demand was monitored for a three-hour period. The idle energy rate was 0.10 kw. The duty cycle, or percentage of the holding cabinet s actual energy consumption rate compared to the 1.05 kw measured energy input rate was 9.52% during idle conditions. Results of preheat and idle tests are calculated using EQUATION 1 and are listed in TABLE 3. Table 3. Preheat and Idle Energy Rate Holding Cabinet Preheat Time (min) Preheat Energy (kwh) Preheat Rate ( F /min) Idle Energy Rate (kw) Results 9.03 min kwh 8.51 F /min 0.10 kw Idle Duty Cycle (%) 9.52% Southern California Edison Page 9

15 CONCLUSION The following parameters of the holding cabinet were determined during testing: Energy Input Rate: The maximum energy input rate recorded during the test was 1.04 kw. Preheat Energy Rate: The holding cabinet took 9.03 minutes to reach the temperature of 150 F, yielding a preheat energy rate of 8.51 F/min. Idle Energy Rate: The idle energy rate, the amount of energy required to maintain a 150 F setpoint, was recorded as 0.10kW. Southern California Edison Page 10

16 APPENDIX A Southern California Edison Page 11

17 Southern California Edison Page 12

18 REFERENCES 1 American Society for Testing and Materials, Standard Test Method for performance of Hot Food Holding Cabinets. ASTM Designation F (reapproved 2007)-Revised July 23, In Annual Book of ASTM Standards, West Conshohocken, PA 1 Southern California Edison Page 13

CONVECTION OVENS FOR FOOD SERVICE APPLICATIONS BLODGETT SHO-E

CONVECTION OVENS FOR FOOD SERVICE APPLICATIONS BLODGETT SHO-E Design & Engineering Services CONVECTION OVENS FOR FOOD SERVICE APPLICATIONS BLODGETT SHO-E Report ` Prepared by: Design & Engineering Services Customer Service Business Unit Southern California Edison

More information

INTEGRATION OF DEMAND RESPONSE INTO TITLE 20 FOR HOT FOOD HOLDING CABINETS

INTEGRATION OF DEMAND RESPONSE INTO TITLE 20 FOR HOT FOOD HOLDING CABINETS Design & Engineering Services INTEGRATION OF DEMAND RESPONSE INTO TITLE 20 FOR HOT FOOD HOLDING CABINETS Phase1: Demand Response Potential DR 09.05.07 Report Prepared by: Design & Engineering Services

More information

VARIABLE REFRIGERANT FLOW FOR LODGING

VARIABLE REFRIGERANT FLOW FOR LODGING Design & Engineering Services VARIABLE REFRIGERANT FLOW FOR LODGING APPLICATIONS Report Prepared by: Design & Engineering Services Customer Service Business Unit Southern California Edison June 2012 Acknowledgements

More information

Food Service Technology Center

Food Service Technology Center Food Service Technology Center IR Energy Habanero HAB-M50 Gas Patio Heater Test Report Application of ASTM Standard Test Method FF2644-07 September 2014 Prepared by: Elan Frantz Trey Young Fisher-Nickel,

More information

Southern California Gas Company Customer Programs Department

Southern California Gas Company Customer Programs Department Appliance Test Report SCGAT140220A Revision 0 Issued Date: March 2014 Duke 613Q-G1V Gas Convection Oven Performance Test Per ASTM F1496-13 Southern California Gas Company Customer Programs Department Food

More information

Food Service Technology Center

Food Service Technology Center Food Service Technology Center Eloma Genius T6-11 Gas Combination Oven Test Report FSTC Report # 501311112-R0 Application of ASTM Standard Test Method F2861-10 August 2012 Prepared by: Michael Karsz Denis

More information

INTEGRATION OF DEMAND RESPONSE INTO TITLE 20 FOR COMMERCIAL ICE MACHINES

INTEGRATION OF DEMAND RESPONSE INTO TITLE 20 FOR COMMERCIAL ICE MACHINES Design & Engineering Services INTEGRATION OF DEMAND RESPONSE INTO TITLE 20 FOR COMMERCIAL ICE MACHINES Phase1: Demand Response Potential DR 09.05.06 Report Prepared by: Design & Engineering Services Customer

More information

Food Service Technology Center

Food Service Technology Center Food Service Technology Center Ovention M1718 Oven FSTC Report # 501311203-R0 Application of ASTM Standard Test Method F2238-09 December 2013 Prepared by: Kong Sham Fisher-Nickel, Inc.. Prepared for: Pacific

More information

Food Service Technology Center

Food Service Technology Center Food Service Technology Center Rational SCC WE 202G Gas Combination Oven Test Report FSTC Report # 501311101-R0 Application of ASTM Standard Test Method F2861-10 March 2012 Prepared by: Michael Karsz David

More information

F Prepared by: Kong Sham. Prepared for: PO Box Technology Center

F Prepared by: Kong Sham. Prepared for: PO Box Technology Center Food Service Technology Center Merrychef eikon e2 Appliance Test Report FSTC Report # 501311081 Application of ASTM Standard Test Method F2238-09 December 2011 Prepared by: Kong Sham David Zabrowski Fisher-Nickel,

More information

Sunglo Heater Model A270 Patio Heater Performance Test

Sunglo Heater Model A270 Patio Heater Performance Test Sunglo Heater Model A270 Patio Heater Performance Test FSTC Report # 5011.07.01 January 2007 Prepared by: Greg Sorensen David Zabrowski Fisher-Nickel, Inc. 2007 by Fisher-Nickel, inc. All rights reserved.

More information

LED HYBRID PATHWAY LIGHTING for The National Park Service

LED HYBRID PATHWAY LIGHTING for The National Park Service Design and Engineering Services LED HYBRID PATHWAY LIGHTING for The National Park Service PRELIMINARY TECHNOLOGY ASSESSMENT Statewide Emerging Technologies Funding Program Prepared by: Design and Engineering

More information

Food Service Technology Center

Food Service Technology Center Food Service Technology Center CMA-180 / CMA-180-VL Dishwashing Machine Expanded Test Report FSTC Application of ASTM Standard Test Methods F1696-07 and F2474-09 January 2013 Prepared by: Denis Livchak

More information

Evaluation of Low Pressure Dryer for Plastic Resins

Evaluation of Low Pressure Dryer for Plastic Resins Design & Engineering Services Evaluation of Low Pressure Dryer for Plastic Resins ET 08.09 Final Report Design & Engineering Services Customer Service Business Unit Southern California Edison July 27,

More information

Metcraft Power Soak Performance Test

Metcraft Power Soak Performance Test Metcraft Power Soak Performance Test FSTC Report 5011.02.11 Food Service Technology Center Final Report, May 2002 Prepared by: Charles Bohlig Victor Kong Fisher-Nickel, inc. 2002 by Fisher-Nickel, inc.

More information

Sunpak Heater Model S25 Patio Heater Performance Test

Sunpak Heater Model S25 Patio Heater Performance Test Sunpak Heater Model S25 Patio Heater Performance Test FSTC Report # 5011.06.20 December 2006 Prepared by: Greg Sorensen David Zabrowski Fisher-Nickel, Inc. 2006 by Fisher-Nickel, inc. All rights reserved.

More information

OFF-GRID COMMERCIAL DIRECT CURRENT GRID SYSTEM

OFF-GRID COMMERCIAL DIRECT CURRENT GRID SYSTEM Design & Engineering Services OFF-GRID COMMERCIAL DIRECT CURRENT GRID SYSTEM Report Prepared by: Design & Engineering Services Customer Service Business Unit Southern California Edison December 2012 Acknowledgements

More information

FSTC Equipment Test Report

FSTC Equipment Test Report FSTC Equipment Test Report Purpose of Testing The Stirling Ultracold SU780XLE freezer was tested to characterize its energy usage and temperature stability during periods of both idle and door openings

More information

Calculated Energy Savings for Disabling Anti- Sweat Door Heat on Glass Display Case Doors

Calculated Energy Savings for Disabling Anti- Sweat Door Heat on Glass Display Case Doors Calculated Energy Savings for Disabling Anti- Sweat Door Heat on Glass Display Case Doors ET Project Number: Product Manager: Sachin Andhare Pacific Gas and Electric Company` Prepared By: Danielle Geers

More information

Refrigerated Prep Table Performance Testing

Refrigerated Prep Table Performance Testing Refrigerated Prep Table Performance Testing FSTC Report # 5011.03.16 September 2003 Prepared by: David Zabrowski David Cowen Fisher-Nickel, Inc. Contributor: Scott Miner Fisher-Nickel, Inc. 2003 by Fisher-Nickel,

More information

Middleby Marshall Conveyor Oven, PS 360WB Conveyor Oven Performance Test

Middleby Marshall Conveyor Oven, PS 360WB Conveyor Oven Performance Test Middleby Marshall Conveyor Oven, PS 360WB Conveyor Oven Performance Test Application of ASTM Standard Test Method F 1817-97 FSTC Report 5011.98.63 Food Service Technology Center Manager: Don Fisher Final

More information

Market Forge, STP-6E Electric Steamer Performance Test

Market Forge, STP-6E Electric Steamer Performance Test Market Forge, STP-6E Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.01.05 Food Service Technology Center Final Report, December 2001 Prepared by:

More information

Vanguard Powermax 200 Gas-Fired Booster Heater Performance Tests

Vanguard Powermax 200 Gas-Fired Booster Heater Performance Tests Vanguard Powermax 200 Gas-Fired Booster Heater Performance Tests Application of ASTM Standard Test Method F 2022-01 FSTC Report 5011.02.10 November 2002 Prepared by: David Cowen David Zabrowski Fisher-Nickel,

More information

AccuTemp STEAM n HOLD, Model 208-D6-3.0 Electric Steamer Performance Test

AccuTemp STEAM n HOLD, Model 208-D6-3.0 Electric Steamer Performance Test AccuTemp STEAM n HOLD, Model 208-D6-3.0 Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-93 FSTC Report 5011.98.58 Food Service Technology Center Manager: Don Fisher Final

More information

Thermo Scientific ULT Freezers: Superior Thermal Performance

Thermo Scientific ULT Freezers: Superior Thermal Performance Thermo Scientific ULT Freezers: Superior Thermal Performance Abstract In addition to being able to reach and maintain temperatures as low as -86 C, today s ultra-low temperature (ULT) laboratory freezers

More information

Precision Temp PT-56 Gas-Fired Booster Heater Performance Tests

Precision Temp PT-56 Gas-Fired Booster Heater Performance Tests Precision Temp PT-56 Gas-Fired Booster Heater Performance Tests Application of ASTM Standard Test Method F 2022-00 FSTC Report 5011.03.28 October 2003 Prepared by: David Cowen David Zabrowski Fisher-Nickel,

More information

Food Service Technology Center

Food Service Technology Center Food Service Technology Center Hobart PW10eR Electric Pot and Pan Door-Type Dishwashing Machine Test Report Application of ASTM Standard Test Method F1696-15 & F2474-09 February 2016 Prepared by: Rich

More information

Food Service Technology Center

Food Service Technology Center Food Service Technology Center CMA-180-VL-FL Electric Door-Type Heat Recovery Dishwashing Machine Test Report Application of ASTM Standard Test Method F1696-15 and F2474-09 May 2016 Prepared by: Edward

More information

Montague, Model Vectaire HX63A Gas Full-Size Convection Oven Performance Test

Montague, Model Vectaire HX63A Gas Full-Size Convection Oven Performance Test Montague, Model Vectaire HX63A Gas Full-Size Convection Oven Performance Test Application of ASTM Standard Test Method F 1496-93 FSTC Report 5011.99.79 Food Service Technology Center Final Report, December

More information

Tankless On Demand Electric Water Heater

Tankless On Demand Electric Water Heater ECO FRIENDLY 98% EFFICIENT ENERGY & WATER SAVING Model MTX Tankless On Demand Electric Water Heater Available Up To 54 KW in Single or Three Phase Voltages Marine Approvals American Bureau of Shipping

More information

Electric radiator tests

Electric radiator tests Electric radiator tests Carried out for Haverland By P Stonard 16 July 2010 Electric radiator tests Carried out for: Haverland Avda San Martin De Valdeigiesias Km-2,200 Alcorcon MADRID 28925 Spain Contract:

More information

Demand Response Potential of Residential Appliances Clothes Washer (LG)

Demand Response Potential of Residential Appliances Clothes Washer (LG) Design & Engineering Services Demand Response Potential of Residential Appliances Clothes Washer (LG) Prepared by: Design & Engineering Services Customer Service Business Unit Southern California Edison

More information

Electric radiator test

Electric radiator test Electric radiator test Final Report 56161/1 Carried out for Cornwall Heating Solutions Ltd & Bright Heating By Calum Maclean 27 June 2012 Electric radiator test Carried out for: Cornwall Heating Solutions

More information

Cylinders for Domestic Purposes Heat Pumps

Cylinders for Domestic Purposes Heat Pumps Testing of Cylinders for use with heat pumps HWA 002:2015 Page 1 of 10 HOT WATER ASSOCIATION SPECIFICATION HWA 002:2015 Cylinders for Domestic Purposes Heat Pumps Specification of requirements and test

More information

A Dual Setpoint Controller for Combination Service Boilers

A Dual Setpoint Controller for Combination Service Boilers Engineering Measurement & Verification Study: A Dual Setpoint Controller for Combination Service Boilers Southern California Multi-Family Residential 2010-2011 Emerging Technology Program Copyright 2011

More information

PlateScrape Plate Pre-Scrapper Test Report

PlateScrape Plate Pre-Scrapper Test Report PlateScrape Plate Pre-Scrapper Test Report Application of ASTM Standard Test Method F2324-03 September 2016 Prepared by: Denis Livchak Fisher-Nickel, Inc. Contributors: Andre Hookfin Fisher-Nickel, Inc.

More information

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages Model HX/TX Tankless Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages Features Heavy Duty Construction Constructed with high grade materials to ensure long operating

More information

DGC-1000 DIGITAL GENSET CONTROLLER

DGC-1000 DIGITAL GENSET CONTROLLER DGC-1000 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-1000) offers a low cost microprocessor based integrated alternative for small to medium sized genset control and monitoring.

More information

Specification for On-Line UPS Battery Monitoring and Data Management System

Specification for On-Line UPS Battery Monitoring and Data Management System 1 Scope This specification defines the minimum requirements for a predictive on-line Battery Monitoring BMDMS with test, analysis, and remote monitoring control capabilities. Unless noted otherwise, the

More information

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual MANUAL Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual Model FPT 130 Single Point Freeze Protection Heat Trace Control Table of Contents SCFP-CO-F130 Overview... 3 Installation...

More information

Cool Savings Program Report

Cool Savings Program Report Cool Savings Program Report Prepared by: Michael Fung Jennifer Wang San Francisco Department of the Environment 1455 Market St. Suite 1200 San Francisco, CA 94103 Technical Contributors: Denis Livchak

More information

SMALL MOTOR CONTROLLERS

SMALL MOTOR CONTROLLERS Research PERFORMANCE ANALYSIS OF SMALL MOTOR CONTROLLERS October, 1994 Southern Company Services, Inc. Marketing Services Customer Technology Research Prepared by: Jeffrey A. Burleson, P.E. The Southern

More information

HPLC Column Ovens and Temperature Controllers

HPLC Column Ovens and Temperature Controllers HPLC Column Ovens and Controllers Improve your separation performance today! Accurate temperature control of your HPLC columns will improve the reproducibility of your results. Operating at increased temperatures

More information

Evaluation Report 509

Evaluation Report 509 Printed: June 1987 Tested at: Lethbridge ISSN 0383-3445 Group 5i Evaluation Report 509 Prairie Pride TR-36 Series Ventilation Fans A Co-operative Program Between ALBERTA FARM MACHINERY RESEARCH CENTRE

More information

FIELD TEST OF HYBRID ROOFTOP UNIT PHASE 1

FIELD TEST OF HYBRID ROOFTOP UNIT PHASE 1 Design & Engineering Services FIELD TEST OF HYBRID ROOFTOP UNIT PHASE 1 Report Prepared by: Design & Engineering Services Customer Service Business Unit Southern California Edison December 2012 Acknowledgements

More information

Stability & Shelf Life

Stability & Shelf Life Stability & Shelf Life Test Chambers Lunaire Environmental provides the largest selection of standard size test chambers as well as temperature/humidity ranges to accommodate all required protocols. Our

More information

ISO-9001:2008 FURNACES CATALOG. Phone: Fax: Web:

ISO-9001:2008 FURNACES CATALOG. Phone: Fax: Web: ISO-9001:2008 FURNACES CATALOG Phone: 281 496 0900 Fax: 281 496 0400 Email: sales@expotechusa.com Web: www.expotechusa.com 32 Digital control offers simple economical operation Ideal for ignition tests,

More information

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

AccuTemp Steam n Hold, Model 208-D8-300 and 400 Electric Steamers In-Kitchen Appliance Performance Report

AccuTemp Steam n Hold, Model 208-D8-300 and 400 Electric Steamers In-Kitchen Appliance Performance Report AccuTemp Steam n Hold, Model 208-D8-300 and 400 Electric Steamers In-Kitchen Appliance Performance Report FSTC Report 5011.01.90 Food Service Technology Center Manager Final Report, December 2001 Prepared

More information

Furnaces. High Temperature Box Furnaces Deluxe Muffle Furnaces Economy Muffle Furnaces... 38

Furnaces. High Temperature Box Furnaces Deluxe Muffle Furnaces Economy Muffle Furnaces... 38 Three Zone Tube Furnace Economy Furnace Lab-Line furnaces are designed to deliver the greatest possible accuracy, convenience and safety. Many models feature precise microprocessor temperature control

More information

Title Page. Report Title: Downhole Power Generation and Wireless Communications. for Intelligent Completions Applications

Title Page. Report Title: Downhole Power Generation and Wireless Communications. for Intelligent Completions Applications Title Page Report Title: Downhole Power Generation and Wireless Communications for Intelligent Completions Applications Type of Report: Quarterly Progress Report Project Report Period: Start Date April

More information

Energy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015

Energy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015 Energy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015 Version 2.0 January, 2015 Prepared for Pacific Gas and Electric Company San Francisco, California Prepared by Energy Solutions

More information

Northeast Utilities. C&LM Programs

Northeast Utilities. C&LM Programs C&LM Programs VendingMiser Monitoring Project FINAL REPORT April 2001 Prepared for: Conservation and Load Management Department 66 Curtis Street New Britain, CT. 06052 Prepared by: The Nicholas Group P.

More information

Building Department Informational Handout

Building Department Informational Handout City of Sonoma Building Department Informational Handout Residential Water Heaters Handout No: 15 Revised: 4/26/18 A water heater is an appliance designed to supply hot water and is equipped with automatic

More information

City of Duluth Festival Center 04/25

City of Duluth Festival Center 04/25 SECTION 230593 - TESTING, ADJUSTING, AND BALANCING FOR HVAC PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

OTFAMU Fresh Air Make Up System For Chilled Water OPERATOR S MANUAL. Technicold Marine Systems

OTFAMU Fresh Air Make Up System For Chilled Water OPERATOR S MANUAL. Technicold Marine Systems OTFAMU Fresh Air Make Up System For Chilled Water OPERATOR S MANUAL Technicold Marine Systems www.technicold.com Technicold by Northern Lights 1419 W. Newport Center Drive Deerfield Beach, FL 33442 Tel:

More information

incubator, the best in its class

incubator, the best in its class 188 188 188 EuroClone incubator, the best in its class More than a new tool: an environment with unique and unmatched features for your cell cultures. ED AN UCED I DESIGNED AND PRODUCED IN ITALY 1 The

More information

Utilizing Finite Element Analysis (FEA) for Flexible Heater Designs

Utilizing Finite Element Analysis (FEA) for Flexible Heater Designs Utilizing Finite Element Analysis (FEA) for Flexible Heater Designs Ryan Mohs, Process Engineer, All Flex. Flexible heaters are commonly utilized in many different heating applications. Generally, these

More information

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015 OPERATING MANUAL EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC DOCUMENT NUMBER IN35-03 Revised 15 May 2015 TORREY PINES SCIENTIFIC, INC. 2713 Loker Ave. West Carlsbad,

More information

DGC-500 DIGITAL GENSET CONTROLLER

DGC-500 DIGITAL GENSET CONTROLLER DGC-500 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-500) offers a low cost microprocessor based integrated alternative for the control and monitoring of small to medium sized

More information

Cleveland, Model OEB-6.20 Electric Combination Oven Performance Test

Cleveland, Model OEB-6.20 Electric Combination Oven Performance Test Cleveland, Model OEB-6.20 Electric Combination Oven Performance Test Application of ASTM Standard Test Method F 1639-05 FSTC Report # 5011.07.11 September 2007 Prepared by: Greg Sorensen Fisher-Nickel,

More information

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages Point-of-Use Tankless Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages Features Heavy Duty Construction Reliability Constructed with high grade materials to ensure long operating

More information

Schwank, Model 2312 Patio Heater Performance Test

Schwank, Model 2312 Patio Heater Performance Test Schwank, Model 2312 Patio Heater Performance Test FSTC Report # 5011.07.15 June 2007 Prepared by: Greg Sorensen David Zabrowski Fisher-Nickel, Inc. Prepared for: Pacific Gas & Electric Company Customer

More information

Food Service Technology Center Promoting Energy Efficiency in Food Service

Food Service Technology Center Promoting Energy Efficiency in Food Service Account Information & Energy Potential Date Month/Day/Year 6-Oct-10 Account Number(s) Account Id # Customer Information Business Name Rubios Contact Name Tabitha Smith Title Manager Street Address on UCSD

More information

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu) PART 1 - GENERAL A. RELATED DOCUMENTS SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu) Federal, State, and local requirements as applicable. Attached Permit Attached drawings B. SUMMARY 1. Provide

More information

2019 Smart Energy Existing Homes Program Manual

2019 Smart Energy Existing Homes Program Manual 2019 Smart Energy Existing Homes Program Manual Reduce the Use: Residential Table of Contents INTRODUCTION... 1-1 1.1 PROGRAM OVERVIEW... 1-1 1.2 PROGRAM ASSISTANT... 1-1 1.3 SANTEE COOPER RESIDENTIAL

More information

Air & Water Heat Pump R832

Air & Water Heat Pump R832 Figure 1 : R832 P.A. Hilton Ltd Air & Water Heat Pump R832 Vapour Compression Heat Pump that allows Performance Investigation from both Air and Water Sources. Rapid Stabilisation enables detailed Investigation

More information

Netbiter Tank Sensor

Netbiter Tank Sensor For Netbiter Tank Sensor HMS Industrial Networks AB Post address: Box 4126 300 04 Halmstad SWEDEN Visitor s address: Stationsgatan 37 302 45 Halmstad SWEDEN Telephone: + 46 35 17 29 00 Fax: + 46 35 17

More information

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External

More information

ASME Packaged Electric Water Heater

ASME Packaged Electric Water Heater MODEL SH & H ASME Packaged Electric Water Heater 15-1600 KW - All Voltages & Phases, 80-5000 Gallon Capacity Features Reliable Packaged System Only high grade materials used in construction to ensure long

More information

Freezers. Laboratory & Plasma. i.series Horizon Series. Distinctly. Innovation can be beautiful.

Freezers. Laboratory & Plasma. i.series Horizon Series. Distinctly. Innovation can be beautiful. Innovation can be beautiful. Freezers Laboratory & Plasma Distinctly Freezers Laboratory & Plasma Precisely executed. Sharply designed. Helmer has provided high-quality laboratory equipment and refrigerated

More information

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems A Safe, Stable Environment for Culturing Cells Ultra-reliable Queue water-jacketed CO 2 incubators are carefully engineered to provide an optimal, stable growing environment for cultures. Easy Set-Up Control

More information

Evaluating the Water Savings Potential of Commercial Connectionless Food Steamers. FINAL REPORT June Angelo Karas Victor Kong Don Fisher

Evaluating the Water Savings Potential of Commercial Connectionless Food Steamers. FINAL REPORT June Angelo Karas Victor Kong Don Fisher Evaluating the Water Savings Potential of Commercial Connectionless Food Steamers FINAL REPORT June 2005 Prepared by: Angelo Karas Victor Kong Don Fisher Fisher-Nickel, inc. Food Service Technology Center

More information

SECTION DOMESTIC WATER HEATERS

SECTION DOMESTIC WATER HEATERS SECTION 223500 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

Groen Vortex, Model VRC-6E Electric Steamer Performance Test

Groen Vortex, Model VRC-6E Electric Steamer Performance Test Groen Vortex, Model VRC-6E Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report # 5011.03.23 May 2003 Prepared by: Victor Kong David Zabrowski Fisher-Nickel,

More information

Study Final Report. Priority Cool Refrigerant Study

Study Final Report. Priority Cool Refrigerant Study Refrigerant Study Study Final Report Prepared for: Greenway Solutions Company, Inc. 120 Bethpage Road, Suite 304 Hicksville, New York 11801 Prepared by: WSP Flack + Kurtz 512 Seventh Avenue New York, NY

More information

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions 36-144 kw (122,800-491,300 BTUs) Certified Lead-Free Design New & Improved Pressure Drop Advantage Variable Temp Heat Exchanger NEMA 4 enclosure standard Independent Safeties ETL and cetl certified to

More information

HPF 1.2 NEW INTERCONNECTION SYSTEM FOR EXTREME VIBRATION REQUIREMENTS IN THE VEHICLE

HPF 1.2 NEW INTERCONNECTION SYSTEM FOR EXTREME VIBRATION REQUIREMENTS IN THE VEHICLE HPF 1.2 NEW INTERCONNECTION SYSTEM FOR EXTREME VIBRATION REQUIREMENTS IN THE VEHICLE Authors: Stefan Glaser Senior Manager Customer Engineering VWA Waldemar Stabroth Director Technical Marketing Contact:

More information

TEST REPORT ON. TESTED FOR: Central States Manufacturing, Inc. 302 Jane Place Lowell, AR Phone: (800) Fax: (800)

TEST REPORT ON. TESTED FOR: Central States Manufacturing, Inc. 302 Jane Place Lowell, AR Phone: (800) Fax: (800) TEST REPORT ON CENTRAL STATES MANUFACTURING, INC. S CENTRAL-SNAP PANELS (24 GA., 1.75" HIGH, 16" WIDE PANEL) AT 5' 0" 3' 9" PANEL SPANS IN ACCORDANCE WITH ASTM E1646-95(2011) & E1680-11 TESTED FOR: Central

More information

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions Pre-assembled skid system Back-to-Back heater models, SNA & SNAR High Flow Demand Safety Shower Applications 216-288 kw (737,000-983,000 BTUs) Temperature overshoot purge system NEMA 4 enclosure standard

More information

BD Viper Lysing Heater Manual (for BD Viper System)

BD Viper Lysing Heater Manual (for BD Viper System) BD Viper Lysing Heater Manual (for BD Viper System) 2008/04 Becton, Dickinson and Company Document Number: 8018634 7 Loveton Circle Sparks, Maryland 21152 USA Tel: 800.638.8663 BENEX Limited Bay K 1a/d

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-23 83 00.00 20 (April 2006) -------------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-15768N (September 1999) UNIFIED FACILITIES GUIDE

More information

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions 36-144 kw (122,800-491,300 BTUs) Temperature overshoot purge system Certified Lead-Free Design NEMA 4 enclosure standard ASME and NB Certified options available New & Improved Pressure Drop Advantage Dual

More information

DEEMED SAVINGS TECHNICAL ASSUMPTIONS

DEEMED SAVINGS TECHNICAL ASSUMPTIONS Program: Description: Residential income-qualified natural gas and electricity customers have energy efficiency measures performed at no cost. Program References: Measures "Heating Efficiency" and "EC

More information

EXHIBIT 1. Washington Home Energy Savings

EXHIBIT 1. Washington Home Energy Savings EXHIBIT 1 Washington Home Energy Savings Definitions British Thermal Unit (Btu): It is approximately the amount of energy needed to heat 1 pound of water from 39 to 40 Fahrenheit. Contractor: Any party

More information

DEER2015 Update Comments. SCE Comments on Packaged and Split Air Conditioning Equipment

DEER2015 Update Comments. SCE Comments on Packaged and Split Air Conditioning Equipment DEER2015 Update Comments SCE Comments on Packaged and Split Air Conditioning Equipment Process comments: 1. Coordinate effort and map work steam to decrease errors, improve statewide consistency, and save

More information

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions 18-25 kw (61,4000-85,300 BTUs) Low flow activation options at 0.25 and 0.50 GPM (1.0 and 1.9 LPM) Certified Lead-Free Design Variable Temp Heat Exchanger Pressure Drop Advantage NEMA 4 enclosure standard

More information

Liquid Helium Level Instruments

Liquid Helium Level Instruments Liquid Helium Level Instruments Versatile Reliable Affordable AMI American Magnetics, Inc. Excellence in Magnetics and Cryogenics Model 135 Liquid Helium Level Monitor... Sample-and-Hold Level Sensing

More information

Watt-Muncher Load Bank Manual WATT-MUNCHER. Portable Load Bank. 6 June 2018 Simplex Service Page 1 of 13

Watt-Muncher Load Bank Manual WATT-MUNCHER. Portable Load Bank. 6 June 2018 Simplex Service Page 1 of 13 WATT-MUNCHER Portable Load Bank 6 June 2018 Simplex Service 800-637-8603 Page 1 of 13 This manual was last revised: 6 June 2018 For up-to-date information on this product or others, please contact Simplex

More information

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series CHF Series Self-contained heating units designed for optimum operating efficiency and performance Providing trouble-free service and application flexibility! All of the heat generated by the is immediately

More information

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the Radiant Warm Wall Compact Incubator Reduced Oxygen Incubator Automatic Water-Jacketed Incubator, stacked For more than 45 years, Lab-Line has been on the cutting edge of incubator development. Not only

More information

MODULUS CHARACTERISTICS OF GEOSYNTHETICS USED IN ROADWAY CONSTRUCTION

MODULUS CHARACTERISTICS OF GEOSYNTHETICS USED IN ROADWAY CONSTRUCTION MODULUS CHARACTERISTICS OF GEOSYNTHETICS USED IN ROADWAY CONSTRUCTION Prepared by: TenCate TM Geosynthetics North America 365 South Holland Drive Pendergrass, GA 30567 Tel 706 693 2226 Fax 706 693 4400

More information

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers Data sheet USP Conductivity Analyzers A conductivity system designed to meet USP for the Pharmaceutical Industry incorporating automatic Stage 1 test Meets USP requirements ensures compliance

More information

.4 Section Ductwork Low Pressure Metallic to 500 Pa..3 ANSI/ARI 640 Commercial and Industrial Humidifiers.

.4 Section Ductwork Low Pressure Metallic to 500 Pa..3 ANSI/ARI 640 Commercial and Industrial Humidifiers. Issued 2006/08/01 Section 15751 Humidifiers Page 1 of 7 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Submittals..3 Section 01810 Commissioning..4 Section

More information

PQS Independent type-testing protocol

PQS Independent type-testing protocol PQS Independent type-testing protocol WHO/XXX Original: English Distribution: General TITLE: Integrated electronic maximum-minimum thermometer, with factory programmed alarms, for vaccine refrigerators

More information

HEATING AND COOLING REBATES

HEATING AND COOLING REBATES Thank you for choosing to increase your customer's home energy efficiency with heating and cooling rebates. Follow the steps below to ensure eligibility to receive a rebate from the ComEd Energy Efficiency

More information

CONTENTS AUTOMATIC TRANSFER SWITCHES

CONTENTS AUTOMATIC TRANSFER SWITCHES CONTENTS AUTOMATIC TRANSFER SWITCHES PART 1 GENERAL 1.1 Related Documents 1.2 Summary 1.3 References 1.4 Quality Assurance 1.5 Submittals 1.6 Delivery, Storage and Handling 1.7 Instructions And Training

More information

Portable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

Portable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions Portable CNA-Series - Large Industrial Heaters Heavy duty industrial cart options simplify moving heater to various locations 36-72 kw (122,800-245,600 BTUs) Certified Lead-Free Design New & Improved Pressure

More information

Tank, Heater, and Control Operation Manual REV. E DATE: 04May2015

Tank, Heater, and Control Operation Manual REV. E DATE: 04May2015 Tank, Heater, and Control Operation Manual 25-710-804 REV. E DATE: 04May2015 Hanson Research Corporation 9810 Variel Avenue Chatsworth, CA 91311 USA (800) 821-8165 (818) 882-7266 FAX (818) 882-9470 www.hansonresearch.com

More information