1 Product Data 50HX High Efficiency Single-Packaged Heat Pumps 2 to 5 Nominal Tons UNIT 50HX High Efficiency, Single-Packaged Heat Pump for Manufactured Housing and Residential use. Features/Benefits One-piece heat pumps with optional electric heaters; low installation costs; highly efficient, dependable performance; and easy maintenance. Efficient operation High-efficiency design with SEERs (Seasonal Energy Efficiency Ratios) of 12.0 and HSPFs (Heating Seasonal Performance Factors) of up to 7.2. Easy Installation Factory-assembled package is a compact, fully self-contained, heat pump unit that is pre-wired, pre-piped, and pre-charged for minimum installation expense. 50HX units are available in a variety of standard cooling sizes to meet residential requirements. Unit is installed easily on a rooftop or ground-level pad. The optional base rail provides an elevated base. Convertible duct configuration on the 50HX is designed for easy use in either downflow (vertical) or horizontal discharge applications. Carrier means Top Quality and Reliability Each component is designed and tested for years of operation under the harshest conditions Every unit is thoroughly run tested at the factory in each operating mode and evacuated prior to final charging. Automated run testing allows accurate undisputed tests and measurements which are second to none in the industry. Durable, dependable components Scroll compressors are designed for high efficiency. Each scroll compressor is hermetically sealed Copyright 2003 Carrier Corporation Form 50HX-3PD
2 against contamination to help promote longer life and dependable operation. Vibration isolation provides quiet operation. Scroll compressors are standard on all units. Compressors have internal high-pressure and overcurrent protection. Direct-drive multi-speed, PSC (permanent split capacitor) blower motor is standard on sizes and variable speed (integrated control motor) is standard on sizes 048 and 0. Direct-drive, PSC outdoor-fan motors are designed to help reduce energy consumption and provide for cooling operation down to 40 F. Refrigerant system is designed to provide dependability. Liquid refrigerant strainers are used to promote clean, unrestricted operation. Loss-of-charge switch is standard on all units. Each unit leaves the factory with a full refrigerant charge. Refrigerant service connections make checking operating pressures easier. A fixed metering device controls refrigerant flow precisely. Solid-state Time Guard circuit protects the compressor by preventing potentially damaging too-rapid cycling. Time Guard circuit is standard on all units. Indoor and outdoor coils are computerdesigned for optimum heat transfer and cooling efficiency. Outdoor coil is fabricated of copper tube and aluminum fins and is located inside the unit to protect against damage and ensure long life and reliable operation. The outdoor coil is protected by a coil grille. Copper fin coils are also available by special order. These coils are recommended in applications where aluminum fins are likely to be destroyed due to corrosion. They are ideal for seacoast applications. Chronotemp defrost system provides time/temperature-based defrost cycles to maintain unit efficiency. This highly reliable system checks for coil icing conditions at preset time intervals and initiates a defrost cycle only if required. The defrost cycle ends as soon as defrosting is accomplished. The Chronotemp defrost board may be configured for 30, 50, or 90 minutes. Indoor air quality is improved with cleanable foil-faced insulation. Interior surfaces of the indoor compartment are insulated with cleanable foil-faced insulation to help keep the conditioned air from being affected by the outdoor ambient temperature and to provide improved air quality. Unit sloped condensate and drain pan conform to American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) No. 62P. Sloped condensate pan is made of non-corrosive material. Low sound ratings ensure a quiet indoor and outdoor environment with sound ratings as low as 78 db. Easy to service cabinets provide easy accessibility to serviceable components during installation and maintenance. Rounded corners are an important safety feature. A high-quality finish ensures an attractive appearance. The cabinet is constructed of galvanized steel, bonderized and coated with a prepainted baked enamel finish. The paint finish is a non-calking type, and is capable of withstanding Federal Test method Standard No. 141 (Method 61) 500-hour salt spray test. In addition, all internal cabinet panels are primed, allowing the entire unit to have a longer life and more attractive appearance. Compact size enables the unit to be located where space is limited. The standard control system is readily adaptable to all conventional and programmable thermostats. In addition, units are suitable for integration into building monitor control systems if required. All units are designed with a single continuous top piece to eliminate any possible leaking at the seams or gasketing, which tends to deteriorate over time and shift during rigging procedures. Table of contents Page Features/Benefits Model Number Nomenclature ARI Capacities , 4 Physical Data Options and Accessories Dimensions Selection Procedure Performance Data Controls Application Data Electrical Data Typical Wiring Schematics , 24 Typical Piping and Wiring Guide Specifications , 27 2
3 MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH EQUIPMENT MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH EQUIPMENT MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH Features/Benefits (cont) Low-voltage wiring connections are easily made due to the terminal board which is conveniently located for quick simple access. Field-installed accessory electric heaters are available in a wide range of capacities. Single-point wiring kit makes installation simple. Downflow-only option is shipped from factory for vertical ductwork connection and requires no conversion. Optional base rail provides holes for rigging and forklifts as well as an elevated mounting frame that gives additional structural support to horizontal installations. Serviceability Easily accessible refrigerant access ports on all discharge, suction, and liquid lines permit easy and accurate measurements. Model number nomenclature TT Model No. 50HX Single Packaged Electric Heat Pump 50HX 024 Nominal Cooling Capacity (Tons) / / Legend - Coil Fin Type (AL unless noted) AL Aluminum CU Copper Options - - Standard Unit AA Base Rail AB Downflow with Base Rail AC CU Outdoor Coil with Base Rail AT E-Coat on Outdoor Coil with Base Rail Options AU CU Outdoor Coil, CU Indoor Coil (None) Wire Grille with Base Rail AD Louvered CC Grille CU Outdoor Coil BT Wire CU Grille and CU Vinyl-Coated Indoor & Outdoor Condenser Coils Coil Fin TP Tin Plated Indoor Coil Hairpins XT Louvered TB Grille TP and with Vinyl-Coated Base Rail Condenser TC Coil Fin CU Outdoor Coil, Base Rail and TP CC Wire TD Grille, AL E-Coat Evaporator on Outdoor and CU/CU Coil, Base Rail Condenser Coil and TP AC Louvered TE Grille, E-Coat AL Evaporator on Outdoor and Coil CU/ and TP CU condenser TF CU Coil Outdoor Coil and TP AU Louvered TL Grille, TP with CU/CU Downshot Evaporator and Base and Rail Condenser TT Coils E-Coat on Outdoor Coil V-Ph-Hz 3 208/ ARI* capacities COOLING AND HEATING CAPACITIES AND EFFICIENCIES UNIT 50HX ( SERIES) NOMINAL TONS STANDARD CFM NET COOLING CAPACITIES AT 95 F (Btuh) SEER NET HEATING CAPACITIES AT 47 F (Btuh) COP At 47 F (Btuh) NET HEATING CAPACITIES AT 17 F (Btuh) COP At 17 F (Btuh) HSPF SOUND RATINGS** (db) , , , , , , / , , , , , , / , , , , , , , , , , , , db COP DOE HSPF SEER LEGEND Sound Levels (1 bel = 10 decibels) Coefficient of Performance Department of Energy Heating Seasonal Performance Factor Seasonal Energy Efficiency Ratio * Air Conditioning & Refrigeration Institute. Rated in accordance with ARI Standard 210/240, latest revision and/ or U.S. Government DOE test procedures. ** Rated in accordance with ARI Standard 2, latest revision. UNITARY AIR CONDITIONING UNITARY HEAT PUMP SOUND RATING OF OUTDOOR ARI STANDARD 210 ARI STANDARD 240 ARI UNITARY EQUIPMENT STANDARD 2 3
4 ARI* Capacities (cont) OUTDOOR SOUND: OCTAVE BAND DATA DECIBELS FREQUENCY SOUND POWER LEVEL FOR 50HX UNIT (Hz) Physical data UNIT SIZE 50HX REFRIGERANT Refrigerant Control* SHIPPING WEIGHT (lb) Without Base Rails With Optional Base Rails COMPRESSOR TYPE INDOOR FAN Speeds Rpm (High Speed) Diameter (in.) Width (in.) Nominal Airflow (Cfm) Motor Hp INDOOR COIL RowsFins/in. Face Area (sq ft) OUTDOOR FAN Cfm Rpm Diameter (in.) Motor Hp OUTDOOR COIL RowsFins/in. Face Area (sq ft) / / / / *Operating charge listed on unit nameplate. Recommended field-supplied filters are 1 in. thick. NOTE: Sizes 048 and 0 are equipped with an indoor integrated control motor (ICM). R-22 Acutrol System Scroll Centrifugal Direct Drive / / Propeller Direct Drive / / Variable / Variable FILTER SIZE (in.) Throwaway 24 x x x x x x /
5 Options and accessories Factory-installed options Unit with base rail provides holes for rigging and forklifts, as well as an elevated mounting frame that gives additional structural support for horizontal installations. Downflow option provides for easy vertical ductwork connections. Unit is equipped with base rail. Coil options include Tin-Plated* indoor hairpins, copper/copper and vinyl-coated construction for refrigerant coils. Units are shipped standard with copper tube/aluminum fin construction. See model number nomenclature for coil options. *Tin-Plated indoor coils are built with special hairpins that are designed to resist both general pitting corrosion and excessive indoor corrosion (Formicary Corrosion). Field-installed accessories ACCESSORY Roof Curb 8 in. 11 in. 14 in. 30% Manual Outdoor-Air Damper Filter Rack Duct Cover Kit Lifting Bracket Kit Rectangular Duct Connection Kit Outdoor Thermostat Electronic Programmable Thermostat Controls Upgrade Kit Low-Ambient Kit Electric Heat with Single-Point Kit (5.0 to 20.0 kw) Downshot-to-Sideshot Conversion Kit Factory-assembled roof curbs are designed for use on downflow discharge applications. Heavy gage, galvanized steel construction provides one-piece support. The curb complies with the standards of the NRCA (National Roofing Contractors Association). A wood nailing strip is provided for attaching the roofing to the curb. 30% manual outdoor-air damper provides for minimum outdoor air and is manually adjustable. Electronic programmable thermostat provides 2-stage heating and 2-stage cooling control with remote communication ability. Low-ambient kit (Motormaster II device) allows the use of mechanical cooling down to outdoor ambient temperatures as low as 0 F. Electric heaters provide heat in the unit when required. Each package has a heater module that slides into keyed mounting slots in the fan inlet. Heater sizes range from 5.0 to 20.0 kw. An available single-point power supply for the entire unit results in lower installed costs. Controls upgrade kit contains high- and low-pressure switches to provide additional safety features and protect the unit from running at unsuitable pressures. One-inch filter rack features easy installation, service-ability, and high filtering performance. Duct cover kit covers horizontal ducts after unit has been converted to downflow discharge. Kit is not required with the downflow option. Lifting bracket kit provides attachment points for rigging straps. The kit is not required when the unit is equipped with an optional base rail. Rectangular duct connection kit allows easy conversion from round to rectangular ducts. Not required for sizes 048 and 0. Outdoor thermostat allows for staging of electric heaters based on outdoor-air temperatures. Downshot-to-sideshot conversion kit converts a dedicated downshot (vertical) discharge unit to a sideshot (horizontal) discharge unit. 5
6 Dimensions UNIT 50HX ELECTRICAL CHARACTERISTICS SIZES WITHOUT BASE RAIL UNIT WEIGHT CORNER WEIGHT (Lb/Kg) UNIT HEIGHT (in./mm) DIMENSION (in./mm) lb kg A B C D E F / /26 69/31 75/34 56/ / / / /25 87/40 74/34 71/ / /563.4 UNIT CENTER OF GRAVITY 50HX X Y Z / / / / / /286 6
7 Dimensions (cont) UNIT 50HX ELECTRICAL CHARACTERISTICS SIZES WITH OPTIONAL BASE RAIL UNIT WEIGHT CORNER WEIGHT (Lb/Kg) UNIT HEIGHT (in./mm) DIMENSION (in./mm) lb kg A B C D E F / /28 74/34 /36 61/ / / / /28 92/42 79/36 76/ / /647.7 UNIT CENTER OF GRAVITY (in./mm) 50HX X Y Z / / / / / /351 7
8 Dimensions (cont) SIZES WITHOUT BASE RAIL UNIT UNIT ELECTRICAL CORNER WEIGHT (Lb/Kg) WEIGHT 50HX CHARACTERISTICS UNIT Lb Kg A B C D HEIGHT (IN) / /21 103/47 81/37 86/ / / /21 103/47 81/37 86/ / /230-1/ /40 81/37 113/51 76/ / /230-1/ /42 85/39 116/53 / /8 UNIT CENTER OF GRAVITY 50HX X Y Z / / / / / / / / / / / /381 8
9 Dimensions (cont) SIZES WITH OPTIONAL BASE RAIL UNIT UNIT ELECTRICAL CORNER WEIGHT (Lb/Kg) WEIGHT 50HX CHARACTERISTICS UNIT Lb Kg A B C D HEIGHT (IN) / /23 108/49 86/39 91/ / / /23 108/49 86/39 91/ / /230-1/ /43 86/39 118/54 81/ / /230-1/ /44 90/41 121/55 85/ /16 UNIT CENTER OF GRAVITY 50HX X Y Z / / / / / / / / / / / /
10 Dimensions (cont) FLAT PART NO. A CPRFCURB001A00 8'' [203] CPRFCURB002A00 11'' [279] CPRFCURB003A00 14'' [356] 10
11 Dimensions (cont) MANUAL OUTDOOR-AIR DAMPER 17 3/16" FILTER RACKS AND FILTERS 20 1/8" 2 1/2" 8 9/16" (DEEP) 11 1/4" A ACCESSORY PART NUMBER HEIGHT MANUAL CPMOAPAC001A00 24-in OUTDOOR AIR CPMOAPAC002A00 28-in DAMPER CPMOAPAC003A00 34-in ACCESSORY PART NUMBER A FILTER CPFILTRK003A in RACK CPFILTRK002A in 11
12 Selection procedure I Determine cooling and heating requirements at design conditions: Given: Required Cooling Capacity (TC) ,000 Btuh Sensible Heat Capacity (SHC) ,500 Btuh Required Heating Capacity ,550 Btuh Outdoor Entering-Air Temperature F Outdoor-Air Winter Design Temperature F Indoor-Air Winter Design Temperature F Indoor Entering-Air Temperature F edb 67 F ewb Indoor-Air Quantity cfm External Static Pressure in. wg Electrical Characteristics (V-Ph-Hz) edb entering dry bulb ewb entering wet bulb II Select unit based on required cooling capacity. Enter Cooling Capacities table at condenser entering temperature of 95 F, indoor air entering at 1125 cfm and 67 F ewb. The 50HX030 unit will provide a total cooling capacity of 28,0 Btuh and a sensible heat capacity of 21,900 Btuh. For indoor-air temperature other than F edb, calculate sensible heat capacity correction, as required, using the formula foundin Note 3 following the Cooling Capacities tables. NOTE: Unit ratings are net capacities. III Select electric heat. Enter the unit 50HX030 Heating Capacities table at 1125 cfm. At F return indoor air and 20 F air entering outdoor coil, the integreated heating cacpacity is 15,300 Btuh. (Select integrated heating capacity value since deductions for outdoor-coil frost and defrosting have already been made. No correction is required.). Determine additional electric heat capacity in kw. 13,250 Btuh = 3.9 kw of heat required 3414 Btuh/kW Enter the 50HX Electric Heater Package208/240 V, Single-Phase, Single-Point Wiring Connections table on page 22 for unit 50HX030. The 5-kW heater at 240 v most closely satsfies the heating required. To calculate kw at 230 v, multiply the heater kw by multiplation factor 0.92 found in the Wattage Multiplicaiton Factors table on page kw 0.92 = 4.6 kw 4.6 kw 3414 = 15,4 Btuh To calculate kw at 208 v, see Wattage Multiplication Factors table on page 19. Total unit heating capacity is 31,004 Btuh (15, ,4). IV Determine fan speed and power requirements at design conditions. Before entering the air delivery tables, calculate the total static pressure required. From the given, the Accessory Electric Heat Pressure Drop table, Wet Coil Pressure Drop table, and the Filter Pressure Drop table, find: External static pressure 0.40 in. wg Filter 0.08 in. wg Electric heat 0.04 in. wg Wet coil 0.06 in. wg Total static pressure 0.58 in. wg Enter the table for Dry Coil Air Delivery Horizontal and Vertical Discharge at 1125 cfm and 230 V high speed. By interpolation, the standard motor will deliver 0.66 in. wg static pressure. This will adequately handle job requirements. The required heating capacity is 28,550 Btuh. Therefore, 13,250 Btuh (28,550 15,300) addtional electric heat is required. 12
13 Performance data 50HX (2 TONS) Temp (F) Outdoor Ent Air NET COOLING CAPACITIES (cont) Indoor AirCfm/Bypass FactorsBF 0/0.04 0/ /0.05 Indoor Air Ewb (F) * * * 62 TC SHC kw TC SHC kw TC SHC kw TC SHC kw HX Temp (F) Outdoor Ent Air Indoor AirCfm/Bypass FactorsBF 0/0.04 0/ /0.05 Indoor Air Ewb (F) * * * 62 TC SHC kw TC SHC kw TC SHC kw TC SHC kw HX030 (2-1/2 TONS) Temp (F) Outdoor Ent Air See Legend and Notes on page 15. Indoor AirCfm/Bypass FactorsBF 875/ / /0.06 Indoor Air Ewb (F) * * * 62 TC SHC kw TC SHC kw TC SHC kw TC SHC kw
14 Performance data (cont) 50HX036 (3 TONS) Temp (F) Outdoor Ent Air NET COOLING CAPACITIES (cont) Indoor AirCfm/Bypass FactorsBF / / / /0.03 Indoor Air Ewb (F) * * * * 62 TC SHC kw TC SHC kw TC SHC kw TC SHC kw HX042 (3-1/2 TONS) Temp (F) Outdoor Ent Air Indoor AirCfm/Bypass FactorsBF 1225/ / /0.11 Indoor Air Ewb (F) * * * 62 TC SHC kw TC SHC kw TC SHC kw TC SHC kw HX (4 TONS) Temp (F) Outdoor Ent Air See Legend and Notes on page 15. Indoor AirCfm/Bypass FactorsBF 1400/ / /0.06 Indoor Air Ewb (F) * * * 62 TC SHC kw TC SHC kw TC SHC kw TC SHC kw
15 Performance data (cont) 50HX Temp (F) Outdoor Ent Air NET COOLING CAPACITIES (cont) Indoor AirCfm/Bypass FactorsBF 1400/ / /0.06 Indoor Air Ewb (F) * * * 62 TC SHC kw TC SHC kw TC SHC kw TC SHC kw HX0 (5 TONS) Temp (F) Outdoor Ent Air LEGEND BF Bypass Factor Edb Entering Dry-Bulb Ewb Entering Wet-Bulb kw Total Unit Power Input Ldb Leaving Dry-Bulb Lwb Leaving Wet-Bulb SHC Sensible Heat Capacity (1000 Btuh) Net TC Total Capacity (1000 Btuh) Net *At 75 F entering dry bulb (Tennessee Valley Authority [TVA] rating conditions); all others at F entering dry bulb. NOTES: 1. Direct interpolation is permissible. Do not extrapolate. 2. The following formulas may be used: t ldb = t edb t edb = Wet-bulb temperature corresponding to enthalpy of air leaving indoor coil (h lwb ) h lwb = h total capacity (Btuh) ewb 4.5 x cfm Where: h ewb = Enthalpy of air entering indoor coil Indoor AirCfm/Bypass FactorsBF 10/ / /0.04 Indoor Air Ewb (F) * * * 62 TC SHC kw TC SHC kw TC SHC kw TC SHC kw sensible capacity (Btuh) 1.10 x cfm 3. The SHC is based on F edb temperature of air entering indoor coil. Below F edb, subtract (corr factor x cfm) from SHC. Above F edb, add (corr factor x cfm) to SHC. Correction Factor = 1.10 x (1 BF) x (edb ). 15
16 Performance data (cont) HEATING CAPACITIES 50HX Cfm (Std Air) Return Temperature Air Entering Outdoor Coil (F db at % rh) Air (F db) kw kw kw kw kw kw kw kw kw HX Cfm (Std Air) Return Temperature Air Entering Outdoor Coil (F db at % rh) Air (F db) kw kw kw kw kw kw kw kw kw db kw rh LEGEND Heating Capacity (1000 Btuh) (Includes Indoor-Fan Motor Heat) Dry Bulb Total Power Input (Includes Compressor Motor Power Input, Outdoor-Fan Motor Input, and Indoor-Fan Motor Input) Relative Humidity NOTES: 1. indicates integrated ratings. 2. Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 16
17 Performance data (cont) HEATING CAPACITIES 50HX030 (2-1/2 TONS) Cfm (Std Air) Return Temperature Air Entering Outdoor Coil (F db at % rh) Air (F db) kw kw kw kw kw kw kw kw kw HX036 (3 TONS) Cfm (Std Air) Return Temperature Air Entering Outdoor Coil (F db at % rh) Air (F db) kw kw kw kw kw kw kw kw kw kw kw kw db kw rh LEGEND Heating Capacity (1000 Btuh) (Includes Indoor-Fan Motor Heat) Dry Bulb Total Power Input (Includes Compressor Motor Power Input, Outdoor-Fan Motor Input, and Indoor-Fan Motor Input) Relative Humidity NOTES: 1. indicates integrated ratings. 2. Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 17
18 Performance data (cont) HEATING CAPACITIES 50HX042 (3-1/2 TONS) Cfm (Std Air) Return Temperature Air Entering Outdoor Coil (F db at % rh) Air (F db) kw kw kw kw kw kw kw kw kw HX (4 TONS) Cfm (Std Air) Return Temperature Air Entering Outdoor Coil (F db at % rh) Air (F db) kw kw kw kw kw kw kw kw kw db kw rh LEGEND Heating Capacity (1000 Btuh) (Includes Indoor-Fan Motor Heat) Dry Bulb Total Power Input (Includes Compressor Motor Power Input, Outdoor-Fan Motor Input, and Indoor-Fan Motor Input) Relative Humidity NOTES: 1. indicates integrated ratings. 2. Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 18
19 Performance data (cont) HEATING CAPACITIES 50HX (4 TONS) Cfm (Std Air) Return Temperature Air Entering Outdoor Coil (F db at % rh) Air (F db) kw kw kw kw kw kw kw kw kw HX0 (5 TONS) Cfm (Std Air) Return Temperature Air Entering Outdoor Coil (F db at % rh) Air (F db) kw kw kw kw kw kw kw kw kw db kw rh LEGEND Heating Capacity (1000 Btuh) (Includes Indoor-Fan Motor Heat) Dry Bulb Total Power Input (Includes Compressor Motor Power Input, Outdoor-Fan Motor Input, and Indoor-Fan Motor Input) Relative Humidity NOTES: 1. indicates integrated ratings. 2. Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 19
20 Performance data (cont) UNIT 50HX MOTOR SPEED Low Med High Low Med High Low Med High Low Med High DRY COIL AIR DELIVERY* HORIZONTAL AND VERTICAL DISCHARGE (DEDUCT 10% FOR 208 V) UNITS AIR DELIVERY 230 VOLT HORIZONTAL DISCHARGE External Static Pressure (in.wg) Watts Cfm Watts Cfm Watts Cfm Watts Cfm Watts Cfm Watts Cfm Watts Cfm Watts Cfm Watts Cfm Watts Cfm Watts Cfm Watts Cfm * Air delivery values are based on operating voltage of 230 v dry coil, without filter or electric heater. Deduct wet coil, filter, and electric heater pressure drops to obtain external static pressure available for ducting. DRY-COIL AIR DELIVERY* HORIZONTAL AND VERTICAL DISCHARGE FOR INTEGRATED CONTROL MOTOR UNITS AT 230 V UNITS 048 AND 0 20 UNIT SIZE 50HX FAN ONLY (Cfm) COOLING (Cfm) HEATING (Cfm) * Air delivery values are for dry coil at 230 v. Airflow is independent of external static pressure within ± 5% of table values up to 0.8 in. wg. Air delivery is preset at factory. NOTE: Do not operate the unit at a cooling airflow that is less than 350 cfm for each 12,0000 Btuh of rated cooling capacity. Indoor coil icing may occur at airflows below this point. Water blow-off may occur at airflows above 450 cfm per 12,000 Btuh of rated cooling capacity. NOTES: 1. Do not operate the unit at a cooling airflow that is less than 350 cfm for each 12,000 Btuh of rated cooling capacity. Indoor-coil frosting may occur at airflows below this point. 2. Dashes indicate portions of the table that are beyond the blower motor capacity or are not recommended. UNIT SIZE 50HX WET COIL PRESSURE DROP AIRFLOW (cfm) PRESSURE DROP (in. wg)
21 Performance data (cont) ACCESSORY ELECTRIC HEATER PRESSURE DROP (in. wg) HEATER CFM kw FILTER PRESSURE DROP (in. wg) UNIT SIZE FILTER CFM 50HX SIZE (in.) , x x MINIMUM AIRFLOW (CFM) FOR SAFE ELECTRIC HEATER OPERATION SIZE Controls Sequence of operation When power is supplied to unit, the transformer (TRAN) is energized. Cooling With the thermostat subbase in the cooling position, and when the space temperature comes within 2 F of the cooling set point, the thermostat makes circuit R-O. This energizes the reversing valve solenoid (RVS) and places the unit in standby condition for cooling. As the space temperature continues to rise, the second stage of the thermostat makes, closing circuit R-Y. When compressor time delay (5± 2 minutes) is completed, a circuit is made to contactor (C), starting the compressor (COMP) and outdoor-fan motor (OFM). Circuit R-G is made at the same time, starting the indoor-fan motor (IFM) after a 1- second delay. When the thermostat is satisfied, contacts open, deenergizing C. The COMP and OFM stop, and the IFM stops after a short time delay. Heating On a call for heat, thermostat makes circuit R-Y and R-G. When compressor time delay (5 ± 2 minutes) is completed, a circuit is made to C, Starting COMP and OFM. Circuit R-G also starts IFM after 1-second delay. Should room temperature continue to fall, circuit R-W is made through second-stage thermostat bulb. If optional electric heat package is used, a relay is energized, bringing on first bank of supplemental electric heat. When thermostat is satisfied, contacts open, deenergizing contactor and relay; motors and heaters deenergize. The IFM may be controlled by a time-delay relay that keeps the fan on for 30 seconds. Defrost Defrost board (DB) is a time and temperature control, which includes a field-selectable time period between checks for defrost (30, 50, and 90 minutes). Electronic timer and defrost cycle start only when contactor is energize and defrost thermostat (DFT) is closed. Defrost mode is identical to Cooling mode, except OFM stops and a bank of optional electric heat turns on to warm air supplying the conditioned space. Application data Condensate trap A 2-in. condensate trap must be field supplied. 1 MIN. TRAP OUTLET 2 MIN. Maximum cooling airflow To minimize the possibility of condensate blow-off from the evaporator, airflow through the units should not exceed 450 cfm/ton. Minimum cooling airflow The minimum cooling airflow is 350 cfm/ton. Minimum cooling ambient operating temperature All standard units have a minimum ambient operating temperature of 40 F. With accessory low ambient temperature kit, units can operate at temperatures down to 0 F. Maximum operating outdoor air temperature Maximum outdoor operating air temperature for cooling is 125 F. 21
22 Electrical data UNIT 50HX SIZE- SERIES V-PH ( Hz) VOLTAGE RANGE COMPRESSOR OFM IFM ELECTRIC HEAT Min Max RLA LRA FLA FLA kw FLA / / / / / / / / (See Legend following Electrical Data chart) LEGEND FLA Full Load Amps LRA Locked Rotor Amps MCA Minimum Circuit Amps MOCP Maximum Overcurrent Protection RLA Rated Load Amps *Heater capacity (KW) based on heater voltage of 208v, 240v, & 4v. If power distribution voltage to unit varies from rated heater voltage, heater KW will vary accordingly. NOTES: 1. In compliance with NEC (National Electrical Code) requirements for multimotor and combination load equipment (refer to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be Power Supply fuse. The CGA (Canadian Gas Association) units may be fuse or circuit breaker. 2. Minimum wire size is based on C copper wire. If other than C wire is used, or if length exceeds wire length in table, determine size from NEC. 3. Unbalanced 3-Phase Supply Voltage Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percentage of voltage imbalance. % Voltage imbalance max voltage deviation from average voltage = 100 x average voltage 3.75/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /20.0 WATTAGE MULTIPLICATION FACTORS HEATER VOLTAGE RATING 240 ACTUAL HEATER VOLTAGE 18.1/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /83.3 MULTIPLICATION FACTOR SINGLE-POINT POWER SUPPLY 40.3/ / / / / / / / / / / / / / / / / / / / / / / / / /74.4.4/ / / / / / / / /45 / 45/45 / 50/50 / 50/50 / / / Single- Single-Point Point Max Wiring MCA Fuse or Ckt Bkr Single- Point MOCP / / / / 100/110 / / 100/110 / /90 100/ /150 / /90 90/ / /150 / / 90/90 110/ /150 / 90/90 100/ / /175 EXAMPLE: Supply voltage is AB = 452 v BC = 464 v AC = 455 v Average Voltage = = 3 = 457 Determine maximum deviation from average voltage. (AB) =5v (BC) =7v (AC) =2v Maximum deviation is 7 v. Determine percent of voltage imbalance. 7 % Voltage Imbalance = 100 x 457 = 1.53% This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%. IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately. Heater Only Dual- Point Wiring MCA 22.5/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /104.2 DUAL-POINT POWER SUPPLY (INCLUDING UNIT ONLY) Heater Only Dual- Point Max Fuse or Ckt Bkr 25/30 35/40 50/ 25/30 35/40 50/ 25/30 35/40 50/ 25/30 35/40 50/ 25/30 35/40 50/ 25/30 35/40 50/ 25/30 35/40 50/ 25/30 35/40 50/ Heater Only Dual- Point MOCP / / / 100/110 / 100/110 / 100/110 / 100/110 Unit Only Dual- Point MCA Unit Only Dual- Point Max Fuse or Ckt Bkr Unit Only Dual Point MOCP / / / / / / / / EXAMPLE: kw (at 240 v) heater on 230 v = 20.0 (0.92 multiplication factor) = 18.4 kw capacity at 230 v
Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons
Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional
More informationProduct Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz
Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece
More informationProduct Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons
Product Data 50JS Single-Packaged Heat Pump Units 1 1/2 to 5 Nominal Tons UNIT 50JS (STANDARD) Single-Packaged Heat Pump for Residential and Light Commercial Applications Low Sound Levels 10 SEER Features/Benefits
More informationProduct Data. Features/Benefits. 50JS 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons
3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons Product Data UNIT (STANDARD) Single-Package Heat Pump for Residential and Light Commercial Applications Low Sound Levels 10 SEER Features/Benefits
More informationProduct Data. Features/Benefits. 50SX High Efficiency Single-Packaged Cooling Units. 2 to 5 Nominal Tons
Product Data 50SX High Efficiency Single-Packaged Cooling Units 2 to 5 Nominal Tons 50SX High Efficiency, Single-Packaged Cooling Unit for Manufactured Housing and Residential use. Features/Benefits One-piece
More informationModel 655A Sizes
Bryant Air Conditioning SINGLE PACKAGE HEAT PUMP S Model 655A Sizes 018-060 1 1 2 to 5 Tons DESCRIPTION Model 655A is our latest generation of packaged heat pumps for manufactured housing, residential,
More informationProduct Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons
Product Data 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant 2 to 5 Nominal Tons UNIT 50JZ Single-Package Products with Energy-Saving Features and Puron refrigerant. 12 SEER HSPF up
More informationProduct Data. Features/Benefits. 50JZ 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS with Puron (R-410A) Refrigerant 2-1/2 to 5 Nominal Tons
3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS with Puron (R-410A) Refrigerant 2-1/2 to 5 Nominal Tons Product Data UNIT Single-Package Products with Energy-Saving Features and Puron refrigerant. 12 SEER HSPF
More informationModel 702A SINGLE-PACKAGED ELECTRIC HEATING COOLING UNITS. 2 to 5 Nominal Tons UNIT 702A. Form No. PDS 702A.24.3
SINGLE-PACKAGED ELECTRIC HEATING COOLING UNITS Model 702A 2 to 5 Nominal Tons UNIT 702A Single packaged Cooling Unit for Residential and Light Commercial use. FEATURES/BENEFITS One-piece cooling unit with
More informationProduct Data. 50ZH Single-Packaged Heat Pumps. 2 to 5 Tons. Features/Benefits
Product Data 50ZH Single-Packaged Heat Pumps 2 to 5 Tons Single-Package Heat Pump Units with: easy installation design corrosion-proof basepan redesigned aerodynamic fan blade for reduced sound sloped
More informationProduct Data. Features/Benefits. 50GX 3-PHASE SINGLE-PACKAGED ELECTRIC COOLING UNITS 2-1/2 to 5 Nominal Tons
3-PHASE SINGLE-PACKAGED ELECTRIC COOLING UNITS 2-1/2 to 5 Nominal Tons Product Data UNIT Single packaged Cooling Unit for Residential and Light Commercial use. Features/Benefits One-piece cooling unit
More informationProduct Data. 50GS Single-Packaged Electric Cooling Units. 1-1/2 to 5 Nominal Tons
Product Data 50GS Single-Packaged Electric Cooling Units 1-1/2 to 5 Nominal Tons UNIT 50GS Single packaged Cooling Unit for Residential and Light Commercial use. Features/Benefits One-piece cooling unit
More informationPAJ3. Product Specifications
13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,
More informationProduct Data. Features/Benefits. PERFORMANCE 13 50XZ SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons
PERFORMANCE 13 SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons Product Data UNIT Single-Packaged Products with Energy-Saving Features and Puron refrigerant. 13 SEER
More informationProduct Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons
Product Data 50ZP Single-Package Electric Cooling Units 2 to 5 Nominal Tons Single Package Air-Conditioning Units with: easy installation design corrosion-proof basepan pre-painted steel cabinet sloped
More informationUP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT
SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A
More informationProduct Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons
50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons Product Data The 50EES unit with ZP technology is a package air conditioner for manufactured housing, residential, and light commercial
More informationModel 704B Sizes
SINGLE-PACKAGED ELECTRIC COOLING UNITS with Puron (R-410A) Refrigerant Model 704B Sizes 024-060 2 To 5 Nominal Tons UNIT 704B Single-Packaged Products with Energy-Saving Features and Puron refrigerant.
More informationWJH4 Product Specifications
UP TO 14.5 SEER, R 410A PACKAGE HEAT PUMP FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a
More informationProduct Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons
(60Hz) Single-Package Air Conditioners 3-5 Nominal Tons Product Data The is a package air conditioner for manufactured housing, residential, and light commercial applications. The unit design is the result
More informationPAR5. Product Specifications
TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced
More informationProduct Data. 50ZP Single-Package Air Conditioners. 2 to 5 Tons
Product Data 50ZP Single-Package Air Conditioners 2 to 5 Tons UNIT 50ZP The 50ZP unit is a packaged air conditioner for manufactured housing, residential, and light commercial applications. The 50ZP unit
More informationProduct Data. Features/Benefits. PERFORMANCE 13 50XP SINGLE-PACKAGED ELECTRIC COOLING UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons
PERFORMANCE 13 SINGLE-PACKAGED ELECTRIC COOLING UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons Product Data UNIT Single-Packaged Products with Energy-Saving Features and Puron refrigerant. Low
More informationPAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT
SOUND REFRIGERANT ENVIRONMENTALLY PAD3 Product Specifications 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant
More information14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase
SOUND REFRIGERANT ENVIRONMENTALLY PHD4 Product Specifications 14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/230 1 60, Single Phase REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant
More informationProduct Data. Fig. 1 - Unit 50VG -A
50VG---A Performancet 16 SEER 2---Stage Packaged Air Conditioner tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VG -A A09033 Single-Packaged
More information14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2.5 to 5 TONS 208/ , Operating Model Number
SOUND REFRIGERANT ENVIRONMENTALLY PHD4 Product Specifications 14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2.5 to 5 TONS 208/230 3 60, 460 3 60 REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant
More informationWPH4 Product Specifications
Up to 14.5 SEER, 8.0 HSPF PACKAGE HEAT PUMP 2 to 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification
More informationProduct Data. 50GL Single-Package Electric Cooling Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons
Product Data 50GL Single-Package Electric Cooling Units with Puron (R-410A) Refrigerant 2 to 5 Nominal Tons UNIT 50GL Single-Package Products with Energy-Saving Features and Puron refrigerant. Low Sound
More informationPHD3. Product Specifications
SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, 7.7 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant
More informationModel PA1Z SINGLE PACKAGED AIR CONDITIONERS. Size SS-PA1Z-01 DESCRIPTION FEATURES
FACTORY- ASSEMBLED PACKAGE is a compact, fully self-contained, electric cooling unit with horizontal supply and return ducts. The PA1Z units are available in a variety of standard cooling sizes with voltage
More informationProduct Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( )
13 SEER Single--Packaged Heat Pump tem with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons (024--060) Product Data Fig. 1 - Unit Single -Packaged Heat Pump Units with: S easy installation
More informationEER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER
ENVIRONMENTALLY SOUND REFRIGERANT PA4E Product Specifications 9.2 9.5 EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, 400 3 50 REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant
More informationProduct Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons
0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can
More informationProduct Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )
Single---Packaged Air Conditioner tem With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes 024---060) Product Data Unit A10165 The unit is a packaged air conditioner for manufactured housing,
More information50GL Single-Packaged Electric Cooling 50Hz, CE Units with Puron (R-410A) Refrigerant Features/Benefits
Product Data 50GL Single-Packaged Electric Cooling 50Hz, CE Units with Puron (R-410A) Refrigerant 7 to 14 kw (2 to 4 Nominal Tons) UNIT 50GL (50HZ) Single-Packaged Products with Energy-Saving Features
More information15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING
SOUND REFRIGERANT ENVIRONMENTALLY PAN5 Product Specifications 15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R--410A refrigerant
More informationProduct Data. Fig. 1 - Unit 50EZ -A
50EZ---A Comfortt Single---Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single --- And Three ---Phase Units 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50EZ -A A09034 Single-Packaged
More informationProduct Data PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES )
SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES 024-048) Product Data Fig. 1 - Unit Single -Packaged Heat Pump Units with: S Easy installation design
More informationProduct Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )
SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data Unit A10165 This unit is a packaged air conditioner for manufactured
More informationProduct Data. Fig. 1 - Unit 50VR -A
50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged
More informationProduct Data. PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )
SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data 024-048 Size 060 Size Fig. 1 - Unit Single -Packaged Heat Pump Units with:
More informationProduct Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )
PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data Unit PA3Z- B A10165 The PA3Z- B unit is a packaged air conditioner
More information50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron
50VT---C Comfortt 14 SEER Single---Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single Phase 2 --- 5 Nominal Tons (Sizes 24 --- 60) Three Phase 3 --- 5 Nominal Tons (Sizes 36 --- 60) Product
More informationProduct Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons
007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),
More information607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60)
607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60) Product Data A09033 Fig. 1 - Unit 607C - -A Single-Packaged Products
More informationProduct Data. Fig. 1 - Unit 50ES -A
50ES---A Comfortt 13 SEER Single---Packaged Air Conditioner tem With Puron (R---410A) Refrigerant Single and Three Phase 2 --- 5 Nominal Tons (Sizes 24 --- 60) Product Data Fig. 1 - Unit 50ES -A A09034
More informationProduct Data. Features/Benefits. 50LJQ Single-Package Rooftop Heat Pump Units. Nominal 3 to 10 Tons
Product Data 50LJQ Single-Package Rooftop Heat Pump Units Nominal 3 to 10 Tons Single-Package Rooftop Heat Pump Units with the following Standard Features: 2-in. return-air filters Acutrol refrigerant
More informationProduct Data. Fig. 1 - Unit 50VL -A
50VL---A Performancet 14 SEER Single---Packaged Air Conditioner tem with PuronR (R---410A) Refrigerant Single--- And Three---Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VL -A A09033
More informationProduct Data. Fig. 1 - Unit 50EZ -A
50EZ---A Comfortt 13 SEER Single---Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50EZ -A A09034 Single-Packaged
More information15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON
7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products
More informationProduct Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons
Product Data OMNIZONE 50BRN,BZN006-024 Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems 5 to 20 Nominal Tons The 50BRN,BZN water-cooled and remote air-cooled indoor, self-contained units
More informationProduct Data. Fig. 1 - Unit 50XL -A
50XL---A Infinityr 15 SEER Single---Packaged Air Conditioner with PuronR (R---410A) Refrigerant Single Phase 2 --- 5 Nominal Tons (Sizes 24 --- 60) Product Data Fig. 1 - Unit 50XL -A A09032 Single-Packaged
More informationProduct Data. Features/Benefits
, N 3-PHASE SINGLE-PACKAGED GAS HEATING/ELECTRIC COOLING UNITS with Puron (R-410A) Refrigerant 2-1/2 to 5 Nominal Tons Product Data UNIT Single-Package Rooftop Products with Energy-Saving Features and
More informationProduct Data. Features/Benefits. Infinity 13 48XZ Single-Packaged Dual-Fuel Gas Heating/Electric Heat Pump Units with Puron (R-410A) Refrigerant
Product Data Infinity 13 48XZ Single-Packaged Dual-Fuel Gas Heating/Electric Heat Pump Units with Puron (R-410A) Refrigerant 2 to 5 Nominal Tons Single-Packaged Products with Energy-Saving Features and
More informationELECTRIC HEAT Field installed accessory heaters are available in a wide range of capacities with single point wiring connections. High Temp.
PHE Product Specifications ASHRAE 90.1 EFFICIENCY PACKAGE HEAT PUMP UNIT - 13 & 15 Ton REFRIGERATION CIRCUIT Single reciprocating semi -hermetic compressor on all 13 ton units. Dual semi -hermetic compressors
More informationProduct Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving
Product Data 50AH Horizontal Indoor Single-Package Cooling Units 2 to 5 Nominal Tons Single Package Cooling Units Featuring: compact design flexibility easy maintenance high quality and reliability quiet
More informationProduct Data PY3G SINGLE -PACKAGED AIR CONDITIONER AND GAS FURNACE SYSTEM WITH R -410A REFRIGERANT SINGLE AND 3 PHASE 2-5 NOMINAL TONS (SIZES )
SINGLE -PACKAGED AIR CONDITIONER AND GAS FURNACE SYSTEM WITH R -410A REFRIGERANT SINGLE AND 3 PHASE 2-5 NOMINAL TONS (SIZES 024-060) Product Data Fig. 1 - Unit A06079 Single-Packaged Products with Energy
More informationPAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2.5 to 5 TONS 208/ , REFRIGERATION CIRCUIT EASY TO INSTALL AND SERVICE
SOUND REFRIGERANT ENVIRONMENTALLY PAD3 Product Specifications 13 SEER PACKAGE AIR CONDITIONER, 2.5 to 5 TONS 208/230 3 60, 460 3 60 REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant Scroll
More information50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT
-1SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP S W/OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier
More informationProduct Data FEATURES/BENEFITS. 574A ---Low NOx Models Available SINGLE---PACKAGED GAS HEATING/ELECTRIC COOLING UNITS 2To5NominalTons
---Low NOx Models Available SINGLE---PACKAGED GAS HEATING/ELECTRIC COOLING UNITS 2To5NominalTons Product Data Convertible duct configuration Unit is designed for easy use in either downflow or horizontal
More information50TJM Nominal Cooling Capacity Tons HFC R - 410A Refrigerant
Package Rooftop Units Quality Assurance Certificate Reg. No: 04 100 950420 Subject to change without notice Manufacturing point: Jeddah, Saudi Arabia Nearest port of embarkation: Jeddah Islamic port Product
More informationSTANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh
PAS Product Specifications STANDARD EFFICIENCY PACKAGE A/C UNIT - 74 to 26 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual, electrically
More information48XZ Performance 13 SEER Single--Packaged HYBRID HEAT Dual Fuel System with Puron
Performancet 13 SEER Single---Packaged HYBRID HEATr Dual Fuel System with Puronr (R---410A) Refrigerant Single and Three Phase 2---5 Nominal Tons (Sizes 024---060) Product Data C99088 Fig. 1 - Unit Single-Packaged
More informationModel 583A Sizes
SINGLE-PACKAGED GAS HEATING/ELECTRIC COOLING UNITS Model 583A Sizes 024-060 2 to 5 Nominal Tons UNIT 583A Single-Packaged Rooftop Products with Energy-Saving Features. Direct Spark Ignition Low Sound Levels
More informationProduct Data. 604D SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R -410A) REFRIGERANT SINGLE AND 3 -PHASE UNITS 2 to 5 NOM TONS (SIZES )
SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R -410A) REFRIGERANT SINGLE AND 3 -PHASE UNITS 2 to 5 NOM TONS (SIZES 024-060) Product Data Single-Packaged Products with Energy -Saving Features and PuronR
More informationProduct Data. Unit 574D
SINGLE -PACKAGED GAS HEATING/ELECTRIC COOLING UNITS WITH PURON (R -410A) REFRIGERANT SINGLE- AND 3 -PHASE UNITS 1-1/2 to 5 NOM TONS (SIZES 018-060) Product Data Single-Packaged Products with Energy -Saving
More informationASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh
PAE Product Specifications ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT - 278 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual, Electrically
More informationProduct Data. Fig. 1 - Unit 50VL -A
50VL---A Performancet 14 SEER Single---Packaged Air Conditioner tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VL -A A09033 Single-Packaged
More informationProduct Data. Features/Benefits
PERFORMANCE 13 (N) SINGLE-PACKAGED GAS HEATING/ELECTRIC COOLING UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons Product Data UNIT Single-Packaged Products with Energy-Saving Features and Puron
More informationModel 574B Sizes
SINGLE-PACKAGED GAS HEATING/ELECTRIC COOLING UNITS Model 574B Sizes 024-060 2 to 5 Nominal Tons Low NOx Models Available UNIT 574B Single-Packaged Rooftop Products with Energy-Saving Features and Puron
More informationProduct Data. 48GX/48GXN Single-Package Gas Heating/Electric Cooling Units. 2 to 5 Nominal Tons
Product Data 48GX/48GXN Single-Package Gas Heating/Electric Cooling Units 2 to 5 Nominal Tons UNIT 48GX (Shown with Accessory Wire Grille) Single-Package Rooftop Products with Energy-Saving Features. Direct
More informationProduct Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS
Product Data FF1DNA, FF1DNE Fan Coil Units Sizes 018 thru 030 FF1D FEATURES/BENEFITS The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air
More informationProduct Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.
Product Data GEMINI 38AKS028-044 Commercial Air-Cooled Split Systems 50/60 Hz 25 to 40 Nominal Tons (82.8 to 127.0 kw) These dependable split systems match Carrier s indoor-air handlers with outdoor condensing
More informationProduct Data PA4G - - A 14 SEER SINGLE-PACKAGED AIR CONDITIONER SYSTEM WITH R-410A REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60)
- - A 14 SEER SINGLE-PACKAGED AIR CONDITIONER SYSTEM WITH R-410A REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60) Product Data Fig. 1 - Unit - -A A09183 Single-Packaged Products with Energy
More informationR4H4. Product Specifications
R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on
More informationProduct Data. Features/Benefits. 50BYN Single-Package Air Cooled Vertical Packaged Units. 5to20Tons
Product Data 50BYN Single-Package Air Cooled Vertical Packaged Units 5to20Tons The 50BYN units are single-package cooling units with integral air-cooled condensers designed for indoor installations. They
More informationAdvance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units
Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium
More informationProduct Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz
Product Data GEMINI SELECT 09DPS018-030,09DPM035-130 Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz 18 to 130 Nominal Tons (63 to 457 Nominal kw) a38-7096 09DPS030 UNIT WITH LOW SOUND OPTION
More informationHigh Heat COP. High/Low Stage
SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin
More informationProduct Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:
DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR: 2 -speed
More information48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS
48GS(N)018-060 STANDARD EFFICIENCY 48GX(N)024-060 HIGH-EFFICIENCY 48GS(N)-2SB SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION
More information48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS
-3SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING S PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier Corporation
More information48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS
48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,
More informationProduct Data. Fig. 1 - Unit 48XL -A
48XL---A Infinity 15 SEER Single---Packaged Air Conditioner and Gas Furnace with Puron (R---410A) Refrigerant Single Phase 2 --- 5 Nominal Tons (Sizes 24 --- 60) Product Data Fig. 1 - Unit 48XL -A A09032
More informationProduct Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:
PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230
More informationUP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM
EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors
More informationProduct Data. Features/Benefits. 50HJQ016 Single-Package Rooftop Heat Pump Units 50 Hz kw (15 Nominal Tons)
Product Data 50HJQ016 Single-Package Rooftop Heat Pump Units 50 Hz 44.2 kw (15 Nominal Tons) High-performance, single-package rooftop heat pump products with the following industry-leading premium features.
More informationTECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811
Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage
More informationCOMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 20 TONS
Product Specifications COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER S, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without modification.
More informationCAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel
More information1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series
1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor
More informationFF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D
FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are
More informationCHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on all models All models utilize round copper tube, aluminum plate
More informationR4H4. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION
More information50TM COMBINATION HEATING/COOLING UNITS
50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form
More informationN4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz
ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION
More informationModel 581A COMMERCIAL GAS HEATING/ELECTRIC COOLING UNITS. Bryant Air Conditioning. Form No. PDS 581A.155.3B. 13 to 20 Tons DESCRIPTION
Bryant Air Conditioning Model 581A COMMERCIAL SINGLE PACKAGE ROOFTOP Sizes 155-240 GAS HEATING/ELECTRIC COOLING UNITS 13 to 20 Tons Model 581A155,180 Model 581A240 DESCRIPTION The 581A gas heating/electric
More informationProduct Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving
Product Data ROOMTOP 50AH024-096 Standard Efficiency Horizontal Indoor Single-Package Cooling Units with PURON Refrigerant (R-410A) 2 to 8 Nominal Tons The 50AH single-package cooling units feature: ASHRAE
More informationProduct Data PY3P SINGLE-PACKAGED GAS FURNACE/AIR CONDITIONER SYSTEM WITH R-22 REFRIGERANT 2 TO 5 NOMINAL TONS (SIZES ) 1 & 3 PHASE
SINGLE-PACKAGED GAS FURNACE/AIR CONDITIONER SYSTEM WITH R- REFRIGERANT 2 TO 5 NOMINAL TONS (SIZES 024-060) 1 & 3 PHASE Product Data Convertible duct configuration Unit is designed for easy use in either