AS-V/186K Series. Ultraviolet Disinfection Systems. Installation, Operation and Maintenance Manual

Size: px
Start display at page:

Download "AS-V/186K Series. Ultraviolet Disinfection Systems. Installation, Operation and Maintenance Manual"

Transcription

1 AS-V/186K Series Ultraviolet Disinfection Systems MODELS: AS-V 16 AS-V 26 AS-V 36 AS-V 38 AS-V 48 ATS-186K-10 ATS-186K-20 ATS-186K-40 ATS-186K-60 ATS-186K-80 ATS-186K-120 ATS-186K-240 ATS-186K-480 Installation, Operation and Maintenance Manual CAUTION: Read and Follow all safety rules and operating instructions before first use of product. DEALER NAME: DEALER PHONE #: MODEL #: SERIAL #: DATE INSTALLED: Aqua Treatment Service, Inc. 194 Hempt Road Mechanicsburg, PA

2 Aqua Treatment Service, Inc. 2012

3 Table of Contents Installation Instructions: General Safety Instructions... 2 Function / Description... 3 Installation... 4 Installation Diagram... 5 Sanitation Procedure... 6 Maintenance:... 7 Electronic Control: Parts Breakdown: General Overview... 8 Standard System Setup... 9 Monitor System Setup Unit Electronic Control System Specifications: Dimensions: Troubleshooting: Warranty: Aqua Treatment Service, Inc

4 General Safety Instructions WARNING - to guard against injury, basic safety precautions should be observed, including the following: 1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 2. DANGER - To avoid possible electric shock, special care should be taken since water is present near electrical equipment. Unless a situation is encountered that is explicitly addressed by the provided maintenance and troubleshooting sections, do not attempt repairs yourself, refer to an authorized service facility. 3. Carefully examine the disinfection system after installation. It should not be plugged in if there is water on parts not intended to be wet. 4. Do not operate the disinfection system if it has a damaged power cord or plug, if it is malfunctioning or if it is dropped or damaged in any manner. 1. SAVE THESE INSTRUCTIONS. 2. WARNING: The light given off by this unit can cause serious burns to unprotected eyes and skin. Never look directly at a lit UV lamp. When performing any work on the UV Disinfection System, always unplug the unit first. Never operate the UV system while the lamp is outside of the UV chamber. 3. WARNING: The UV lamp inside of the disinfection system is rated at an effective life of approximately 12,000 hours. To ensure continuous water treatment, replace the UV lamp annually with the appropriate Aqua Treatment Services UV lamp. Failure to comply may present a fire hazard. 5. Always shut off water flow and unplug the disinfection system before performing cleaning or maintenance activities. Never yank the power cord to remove it from an outlet. Grasp the plug and pull to disconnect. 6. Do not use this disinfection system for other than the intended use (potable water applications.) The use of attachments not approved, recommended or sold by the manufacturer / distributor may cause an unsafe condition. 7. Intended for indoor use. Do not install this disinfection system where it will be exposed to the weather. Do not store this disinfection system where it will be exposed to temperatures below freezing unless all the water has been drained from it and the water supply has been disconnected. 8. Read and observe all the important notices and warnings on the water disinfection system. 9. If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less Amperes or Watts than the disinfection system rating may over heat. Care should be taken to arrange the cord so that it will not be tripped over or accidentally pulled from the outlet. 2 Aqua Treatment Service, Inc

5 Function The function of this ultraviolet disinfection unit is to provide in excess of 99% reduction of all water borne pathogenic (disease causing) bacteria. The 186K Series will provide >4Log Reduction or 99.99% of bacteria, cysts, and viruses including adenovirus. Applications: Ultraviolet Germicidal Disinfection A.T.S. Ultraviolet Disinfection Units are designed to destroy micro-organisms in water supplies. The Ultraviolet lamp peak radiation of 254 nanometer wavelength (nm) destroys or inactivates the D.N.A. (deoxyribonucleic acid) which absorbs the Ultraviolet radiation. A.T.S. Germicidal Disinfection units meet minimum dosages of 30,000 microwatt second per square centimeter. The 186K Series provides in excess of 186,000uws/cm2 UV dose.maximum CONCENTRATION LEVELS BEFORE ULTRAVIOLET: Turbidity...5 NTU Hardness...7 gpg Color...None Iron ppm Manganese ppm ph ppm Important Note - Pre-filtration equipment may be required if these parameters cannot be maintained. Flow rate must not exceed rated capacity of the unit. Description The AS-V series are of unique design with an ultraviolet germicidal lamp housed within a single quartz sleeve surrounded by a stainless steel pressure chamber. The chamber is fabricated out of 304 Stainless Steel. A removable stainless steel cover exposes electrical components for servicing, when required. The AS-V series come with an ultraviolet lamp designed with a four pin single end connection. The quartz sleeve is intended to be placed through the disinfection chamber and will slightly protrude from each hole in the top plate. The ultraviolet lamp is placed within this quartz sleeve. The U.V. light shines through this specially designed hard quartz sleeve for maximum disinfection efficiency to meet the requirements for bacteria reduction in potable water. The inlet is located at the bottom of the chamber and the outlet is located on the side of the chamber. A Site Port is provided for safe and easy view of operation. Aqua Treatment Service, Inc

6 Installation Pre-Installation Check List Water Pressure If the water pressure is over 100 psi, a pressure reducing valve must be installed before the equipment and set at 85 psi Electrical A grounded electrical outlet with a continuous supply of 110 to 120 volt - 60 hertz current should be located at installation site of the equipment. A drain, must be available within 20 feet of the equipment. Location of the equipment must be where it is not subject to freezing, direct sunlight or room Temperature over 120 F. The equipment must be installed on the cold water line after the well pressure tank or water meter and before it branches off to the water heater. Before putting the unit into final operation follow sanitation procedures as outlined in this manual for proper disinfection. Sanitizing all discharge piping and fittings with chlorine or approved water piping disinfection process. from disinfection unit to point of use removes existing contaminants and gives the unit a clean start. Be sure to rinse with U.V. treated water. A proper flow control must be used to insure only the designated flow through the unit. Installation 1. All plumbing must conform to local codes 2. Location Selection If it is likely that supplementary water treatment equipment will be required, make certain adequate additional space is available. The AS-V series are always placed after the pressure tank and any other type of treatment devices (i.e. softeners, filters). It is recommended to use some form of pre-treatment, such as a cartridge filter, to improve the clearity of the water and to safely disinfect the plumbing system. Do not install any equipment closer to a water heater than a total run of 10 feet of piping between the outlet of the equipment and the inlet to the heater. 3. Water Line Connection 4. Quartz Sleeves and UV Lamps After mounting, install quartz sleeve, O-Ring, and bulb per instructions. Turn on the water slowly, check for leaks, and repair as needed prior to full service operation. NOTE: For more detail on installation, cleaning and maintenance of the UV Lamps and Quartz Sleeves, see page 7 of this manual. NOTE: Once the system has been pressure check for leaks, the system needs to be disinfection using the sanitation procedures. ( See page 6 for instructions.) 5. Electrical Connection Remove twist tie from cord set and extend cord to its full length. Plug into socket that will accept 3-prong. Be sure the electrical outlet is not controlled by a wall switch. Turn power on and set electronic controls to current time of day (refer to user quick reference guide for setup instructions).if hard wiring electrical power make sure you review the wiring diagram and have electrical work done by a licenced electrician. WARNING: 1. Always disconnect electrical power to any U.V. unit before servicing. 2. Under no circumstances should personnel look at a U.V. lamp in operation (EXCEPT through an external Site Port lens located on the outside of the unit). 3. U.V. Disinfection units must always be properly grounded. Close main water supply valve. Open faucets to relieve water pressure and drain system. Mount the equipment into installation position. Assess the installation (i.e. type of pipe, size of lines, etc.) and obtain necessary plumbing fittings for installation. Use Teflon tape on all threaded connections and avoid over tightening. WARNING: If your piping system is subject to impulse pressure resulting in a water hammer condition, a surge tank or other means must be provided to remove this condition; otherwise, this extreme shock pressure condition may rupture or fracture the quartz sleeve. 4 Aqua Treatment Service, Inc

7 Installation Diagram Enlarged view of outlet with Thermal Relief Valve System Controls Thermal ReliefValve Optional-located on UV outlet Lamp Connection Housing Water influent Water effluent Pre-Filter Type of filter will depend on system requirements. UV Sensor Port Shut-off Valve Test Port UV Chamber Shut-off Valve Thermal Relief Drain Line Inlet Thermal Relief drain line and Sanitary Drain Optional with Thermal Relief valve Aqua Treatment Service, Inc

8 Sanitation Procedure IMPORTANCE OF DISINFECTING A WATER SYSTEM: Every new well, or existing water supply system that has been disrupted for service or repair, should be disinfected before it is returned to use. Water in the well and storage tank should be treated with a strong chlorine solution or approved disinfection process to destroy disease organisms. All pipelines and fixtures in the distribution system should be rinsed and flushed with chlorinated water. Upon installation of a U.V. disinfection unit or bulb replacement service, disinfection with chlorine to initially flush the system is recommended to assure line sanitation prior to U.V. start up. The source of chlorine can be ordinary liquid laundry bleach (about 5.25% available chlorine). The quantity required depends on the volume of water to be treated. The United States Environment Protection Agency (EPA) indicated that about 100 parts of chlorine, by weight, mixed in a million parts of water will destroy essentially all water-borne disease organisms. WARNING: 1. Always follow the sanitizing procedure required by applicable state or local laws. 2. Chlorine may break loose iron deposits, slime and organic material. This material will make the water run colored. The material broken loose may plug pump screens. Do not continue to run pump if water doesn t flow. 3. The high level of chlorine required to sanitize a water system is corrosive to most metals and chlorine solution must not be allowed to remain in water system more than 36 hours before being completely flushed from system. 1. Systems With Pre-filter Turn off water. Unscrew Sump, remove filter and fill sump with liquid chlorine or standard bleach. Reattach sump to filter head. Turn water supply on. Go to each cold water line and run the water untill the chlorine is detected. Once chlorine is detected, turn the running water off. Allow chlorine to sit in plumbing for 30 min. To flush chlorine from system, run water at each faucet for several min. After system has been completely flushed, reinstall the filter and perform a bacteriological analysis on the water following all applicable procedures. 2. Systems With No Pre-filter Turn off water. Drain UV Chamber and remove quartz sleeve. Add chlorine through opening down into chamber. (approx 1 qrt.) Reinstall quartz sleeve. Turn water supply on. Go to each cold water line and run the water untill the chlorine is detected. Once chlorine is detected, turn the running water off. Allow chlorine to sit in plumbing for 30 min. To flush chlorine from system, run water at each faucet for several min. After system has been completely flushed, perform a bacteriological analysis on the water following all applicable procedures. 6 Aqua Treatment Service, Inc

9 Maintenance QUARTZ SLEEVE: Installation of the Quartz Sleeve: Always handle quartz sleeves carefully to prevent breaking or chipping. The quartz sleeves are to be clean and free of fingerprints before installing. Remove the compression nut. Install the quartz sleeve through the hole in the stainless steel top plate. Install the O-Ring down over and around the Quartz Sleeve. Place the retaining ring (with ark facing up) over the O-Ring and Quartz Sleeve. Hand-tighten each compression nut to form a compression seal around the Quartz Sleeve. Avoid over tightening the nuts, which may cause a fracture on the end of the Quartz Sleeve. Under normal operating conditions, hand-tightening will provide a 100 psi seal. Do not use any devices to tighten end nuts. Repeat this procedure for the remaining Quartz Sleeves in the chamber. After you have tightened the compression nut and all other plumbing connections, open the outlet valve. Slowly open the inlet valve and flush out all remaining air. Then close the outlet valve and slowly open the inlet valve fully. Check the unit for leaks. If you find a leak at the compression nut, tighten the nut further. If the leak continues, drain the unit and inspect the quartz O-Ring and Quartz Sleeve for proper seal. Once you complete checking the unit, reassemble O-Ring, retaining ring and gland nut. Repressurize the unit and check again. UV LAMPS: Installation of the UV Lamps: **DO NOT PUT POWER ON AT THIS TIME!** CAUTION: Never look directly at an operating U.V. lamp. Never operate a U.V. lamp outside the disinfection chamber. Make sure unit is unplugged when installing or servicing ultraviolet lamp. Remove any paper tabs on the U.V. lamp and avoid allowing fingerprints and other debris to deposit. Carefully place the lamp inside the quartz sleeve leaving enough space to connect the socket connector to the lamp pins. Requirements for Cleaning the UV Lamps: The U.V. lamp is rated for 12,000 hours of continuous use. After this period of time, the U.V. lamp has undergone a photochemical change. While the lamp will not normally be burned out, the lamp quartz may no longer emit the 254-nm shortwave U.V. to effectively kill bacteria. Failure to replace the U.V. lamps every 12,000 hours may cause bacteriological breakthrough. Should the use of the disinfection unit be intermittent, in no case should the U.V. lamp be used for more than 16 months regardless of the number of hours of operation due to normal shelf life degradation of the U.V. bulb. Changing the quartz sleeve should be done at the same time U.V. lamp replacement is scheduled. Requirements for Cleaning the Quartz Sleeve: As water passes through the U.V., minerals, debris and other matter in the water may deposit onto the Quartz Sleeve. After sufficient film has formed on the Quartz Sleeve, the ability of the ultraviolet germicidal rays to pass though the Quartz Sleeve and into the water may be impaired. Therefore, it is necessary to determine a cleaning schedule for the Quartz Sleeve. The frequency will depend on the specific type of water conditions. If the water has been processed through deionization, reverse osmosis, or is distilled, cleaning may be required only once per year. If untreated water is used, the cleaning frequency will vary. A minimum of once yearly is standard recommendation for cleaning and lamp replacement. Your specific situation will vary the frequency time according to the water quality of the home or facility application. It is recommended that your water supply be tested periodically through your local health department or approved certified laboratory. Maintenance Schedule: Replace UV Lamps, Quartz Sleeves and O-Rings 16 months. This will insure the propre function of the unit. Cleaning the Quartz Sleeve: To clean the Quartz Sleeve, turn off the water flow to the disinfection unit, turn power off, and disconnect the electrical service to the lamp pins. Carefully remove the U.V. lamp. Loosen the compression nuts with O-Rings and remove the Quartz Sleeve while draining the water from the chamber. The Quartz Sleeve may then be washed with a mild soap and hot water solution and rinsed clean with hot water. Should this be insufficient to clean the Quartz Sleeve, a mild acid or an approved cleaning solution may be used (i.e. vinegar). Be certain to follow all recommended safety and handling procedures on the acid container. It is important to handle the Quartz Sleeve with care to prevent breakage. Make certain that all finger prints are wiped clean before reinstalling (see installation of the Quartz Sleeve). Replace O-Rings every time a Quartz Sleeve is cleaned or replaced. Aqua Treatment Service, Inc

10 Electronic Controls Setup Key-Pad 1. System Status Indicater Lamp 2. Alarm Status Indicater Lamp 3. System Display Screen 4. Curser Direction Keys 5. Escape / Back Key 6. Enter Key Aqua Treatment Service, Inc

11 Standard System Setup (No-Probe) Aqua Treatment Service, Inc

12 Electronic Controls Setup Key-Pad 1. System Status Indicater Lamp 2. Alarm Status Indicater Lamp 3. System Display Screen 4. Curser Direction Keys 5. Escape / Back Key 6. Enter Key Aqua Treatment Service, Inc

13 Monitor System Setup Aqua Treatment Service, Inc

14 Parts Breakdown - AS-V16 12 Aqua Treatment Service, Inc

15 Parts Breakdown - AS-V26 Aqua Treatment Service, Inc

16 Parts Breakdown - AS-V36 14 Aqua Treatment Service, Inc

17 Parts Breakdown - AS-V38 Aqua Treatment Service, Inc

18 Parts Breakdown - AS-V48 16 Aqua Treatment Service, Inc

19 Parts Breakdown - ATS-186K-10 Aqua Treatment Service, Inc

20 Parts Breakdown - ATS-186K Aqua Treatment Service, Inc

21 Parts Breakdown - ATS-186K-40 Aqua Treatment Service, Inc

22 Parts Breakdown - ATS-186K Aqua Treatment Service, Inc

23 Parts Breakdown - ATS-186K-80 Aqua Treatment Service, Inc

24 Parts Breakdown - ATS-186K Aqua Treatment Service, Inc

25 Parts Breakdown - ATS-186K Aqua Treatment Service, Inc

26 Parts Breakdown - ATS-186K Aqua Treatment Service, Inc

27 Parts Breakdown - Electronic Control System Monitor Parts Breakdown Front View 1. System Status Lamp 2.Alarm Status Indicator Lamp 3. System Display Screen 4.Curser Direction Keys 5. Escape/Back Key 6. Enter Key 7. Off/On Power Switch 8. Fuse Bottom View: 9. UV Probe Connection 10. Flow Meter Connection 11. RS232 Connection for Software 12. Shutoff Solenoid Power Plug-in 13. Power Cord 14.Pressure Siwtch Connection 15. Cooling Fan 16. Cables Leads to Skid Unit Aqua Treatment Service, Inc

28 Specifications AS - V x 10 x SS 35 lbs. AS - V x 10 x SS 45 lbs. AS - V x 10 x SS 60 lbs. AS - V x 12 x SS 98 lbs. AS - V x 12 x SS 105 lbs. AS - V AS - V AS - V AS - V AS - V Clear Fresh Water at 94% UVT DI / RO Water at 99% UVT DI / RO Water (-03D) at 99% UVT DI / RO Water (TOCR) at 99% UVT 220V Specs are available upon request ATS - THERM ATS - RLCM ATS - STAND ATS - 254P - RLC ATS - ESP ATS - SP ATS - 304NCB ATS - 220V ATS - LT ATS - STC ATS - MW ATS SS Adjustble Settings Thermistor Overheat Safety Control Remote PLC Monitoring Connection Control Box Mounting Stand (powder coated) UV Intensity Monitor / NIST Traceable Calibrated UV Sensor Energy Saver Pacing 1/4 Sample Ports on Inlet / Outlet Riser 304 SS #4 Brushed Finish on Nema 4 Type Control Box Volt / Hz Electrical Components UV Light Traps on Inlet / Outlet Sanitary - Tri - Clamp Fittings Manual Quartz Sleeve Wiper 316 Stainless Steel Wetted Parts 26 Aqua Treatment Service, Inc

29 Specifications ATS-186K x 10 x SS 10 gpm Call for Price ATS-186K x 12 x SS 20 gpm Call for Price ATS-186K /2 36 x 14 x SS 40 gpm Call for Price ATS-186K x 16 x SS 60 gpm Call for Price ATS-186K x 16 x SS 80 gpm Call for Price ATS-186K x 18 x SS 120 gpm Call for Price ATS-186K x 18 x SS 240 gpm Call for Price ATS-186K x 18 x SS 480 gpm Call for Price ATS -STAND Control Box Mounting Stand (powder coated) Call for Price ATS -THERM Adjustable Setting Thermistor Overheat Safety Control Call for Price ATS - ESP Energy Saver Pacing Call for Price ATS - SP 1/4 Sample Port on Inlet/Outlet Riser Call for Price ATS - 304NCB 304 SS #4 Brushed Finish on Nema 4 Type Control Box Call for Price ATS - LT UV Light Traps on Inlet/Outlet Call for Price ATS - STC Sanitary-Tri-Clamp Fittings Call for Price ATS - MW Manual Quartz Slaave Wiper Call for Price ATS SS 316 Stainless Steel Wetted Parts Call for Price 220V Specs are available upon request. System Options installed on Pre or Post Piping are done by Contractor and NOT factory. C.F.C. is Call For Cost See page 30 for replacement part. Aqua Treatment Service, Inc

30 Dimensions OVERAL DIMENSIONS FOR SAPCE REQUIREMENTS Model AS-V 36 NOTE: Dimensions will very slightly with other models *6 * *6 is with 2 pipe, hight may change with larger pipe size. This will also affect the Overall Hight. 28 Aqua Treatment Service, Inc

31 Troubleshooting Aqua Treatment Service, Inc

32 Warranty 30 Aqua Treatment Service, Inc

Hydroflo INSTALLATION & OPERATION MANUAL

Hydroflo INSTALLATION & OPERATION MANUAL Hydroflo U.V. Disinfection INSTALLATION & OPERATION MANUAL This manual covers installation, operation and maintenance requirements for the Hydroflo Ultraflo UV-10A Ultraviolet Disinfection Unit. It is

More information

PurTest PT Series INSTALLATION & OPERATION MANUAL

PurTest PT Series INSTALLATION & OPERATION MANUAL PurTest PT Series U.V. Disinfection INSTALLATION & OPERATION MANUAL This manual covers installation, operation and maintenance requirements for PurTest U.V. Light Disinfection Units. Model PT-8, PT-12,

More information

GDS Series INSTALLATION & OPERATION MANUAL

GDS Series INSTALLATION & OPERATION MANUAL GDS Series U.V. Disinfection INSTALLATION & OPERATION MANUAL This manual covers installation, operation and maintenance requirements for ATS U.V. Disinfection Systems. Model GDS-8, 12, 20 It is important

More information

Triton Series INSTALLATION & OPERATION MANUAL

Triton Series INSTALLATION & OPERATION MANUAL Triton Series U.V. Disinfection INSTALLATION & OPERATION MANUAL This manual covers installation, operation and maintenance requirements for Neptune U.V. Disinfection Systems. Model - TRI-8, TRI-12, TRI-20

More information

GDS Series. Ultraviolet Disinfection Systems. Installation, Operation and Maintenance Manual MODELS: GDS-7 GDS-15

GDS Series. Ultraviolet Disinfection Systems. Installation, Operation and Maintenance Manual MODELS: GDS-7 GDS-15 GDS Series Ultraviolet Disinfection Systems MODELS: GDS-7 GDS-15 Installation, Operation and Maintenance Manual CAUTION: Read and Follow all safety rules and operating instructions before first use of

More information

PFC Series. Ultraviolet Disinfection Systems. Installation, Operation and Maintenance Manual MODELS: PFC-8 PFC-12 PFC-20.

PFC Series. Ultraviolet Disinfection Systems. Installation, Operation and Maintenance Manual MODELS: PFC-8 PFC-12 PFC-20. PFC Series Ultraviolet Disinfection Systems ENHANCED DISINFECTION UV%: 00% DAYS: 364 MODELS: PFC-8 PFC-2 PFC-20 Installation, Operation and Maintenance Manual CAUTION: Read and Follow all safety rules

More information

EV Series INSTALLATION & OPERATION MANUAL

EV Series INSTALLATION & OPERATION MANUAL EV Series U.V. Disinfection INSTALLATION & OPERATION MANUAL This manual covers installation, operation and maintenance requirements for ATS U.V. Disinfection Systems. Model EV-8E, 12E, 20E (During normal

More information

Ultraviolet Water Sterilizer Installation and Maintenance Manual

Ultraviolet Water Sterilizer Installation and Maintenance Manual Ultraviolet Water Sterilizer Installation and Maintenance Manual (Models:GP-UV6W, GP-UV12W, GP-UV55W) INSTALLERS: PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLING AND USING THIS SYSTEM. PERFORMANCE IS GUARANTEED

More information

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance VMS-3 Part Number: 95-0031 Ultraviolet Systems VMS-3 Installation, Operation & Maintenance The following are the types of flags used in this technical manual. They designate safety related items and important

More information

Ultraviolet Disinfection Unit Installation and Owners Manual

Ultraviolet Disinfection Unit Installation and Owners Manual Ultraviolet Disinfection Unit Installation and Owners Manual (PLEASE KEEP FOR PERMANENT REFERENCE) READ THIS MANUAL This manual covers installation, operation, and maintenance requirements for models E,

More information

SUPER NOVA SERIES UV STERILIZER HIGH INTENSITY ULTRAVIOLET STERILIZATION

SUPER NOVA SERIES UV STERILIZER HIGH INTENSITY ULTRAVIOLET STERILIZATION SUPER NOVA SERIES UV STERILIZER HIGH INTENSITY ULTRAVIOLET STERILIZATION Thank you for selecting an Aqua Logic, Inc. Ultraviolet (UV) Sterilizer. Each model has been designed and built to provide years

More information

1020 Industrial Drive, Orlinda, TN fax

1020 Industrial Drive, Orlinda, TN fax Operation Manual Ultraviolet Disinfection System 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and Cautions... 1 1.2 Theory of Operation... 2 1.3

More information

INSTALLATION INSTRUCTIONS & OWNER'S MANUAL!!!!!!!!! P/N

INSTALLATION INSTRUCTIONS & OWNER'S MANUAL!!!!!!!!! P/N INSTALLATI INSTRUCTIS & OWNER'S MANUAL!!!!!!!!! C US P/N 520019 2 SAFETY INSTRUCTIS WARNING - to guard against injury, basic safety precautions should be observed, including the following: 1. READ AND

More information

Heater Upgrade Instructions

Heater Upgrade Instructions Heater Upgrade Instructions Important Safety Precautions It is recommended that you plug the chiller into a GFCI outlet at all times. Do not operate SeaChill chillers or any accessory to SeaChill chillers

More information

Instructions for Emperor Aquatics, Inc. s 16, 25, & 57 Watt Retro-Fit UV Sterilizer (for Savio s Skimmers)

Instructions for Emperor Aquatics, Inc. s 16, 25, & 57 Watt Retro-Fit UV Sterilizer (for Savio s Skimmers) 02934-INS-SAVIO Rev.A Instructions for Emperor Aquatics, Inc. s 16, 25, & 57 Watt Retro-Fit UV Sterilizer (for Savio s Skimmers) Congratulations! Thank you for purchasing our 16, 25, or 57 Watt Retro-Fit

More information

INSTALLATION MANUAL & OWNER S GUIDE. Stainless Steel Ultraviolet Water Purification System

INSTALLATION MANUAL & OWNER S GUIDE. Stainless Steel Ultraviolet Water Purification System INSTALLATION MANUAL & OWNER S GUIDE Stainless Steel Ultraviolet Water Purification System Buv-6 Buv-8 Buv-12 55003.06/17 Specifications Item # 8880 8881 8882 Model # Buv-6 Buv-8 Buv-12 Flow Rate @ 16 mj/cm2

More information

INSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM

INSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM INSTALLATION CAUTIONS Installation must conform to all local and state plumbing codes and regulations. Please read carefully

More information

Ultraviolet (UV) Water Treatment System

Ultraviolet (UV) Water Treatment System water products Ultraviolet (UV) Water Treatment System Installation Instructions & Owner s Manual 12GPUV-55W, 24GPMV-110W, 32GPMV-165W, 48GPMV-220W CAUTION: Before using UV System, read this manual and

More information

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL Ultraviolet Systems Inc. UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL TABLE OF CONTENTS SECTION 1 General Information 1A. Description...1 1B. Specifications...1 SECTION 2 Installation 2A. Pool Preparation...

More information

gamma pond Ultraviolet Sterilizers

gamma pond Ultraviolet Sterilizers gamma pond Ultraviolet Sterilizers Instructions for Models #1410 8w, 1411 15w, 1412 25w, 1403-40w Important Safety Instructions... Page 2 Installation... Page 3 Maintenance & Winterizing... Page 5 Warranty...

More information

ADVANCE Ultraviolet (UV) Water Treatment System

ADVANCE Ultraviolet (UV) Water Treatment System ADVANCE Ultraviolet (UV) Treatment System Installation Instructions & Owner s Manual GAUV-6S, GAUV-10S, GAUV-15S GAUV-12H, GAUV-20H, GAUV-32H CAUTION: Before using UV System, read this manual and follow

More information

I N S T A L L A T I O N, O P E R A T I O N, M A I N T E N A N C E M A N U A L UVR SERIES ULTRAVIOLET WATER TREATMENT SYSTEM

I N S T A L L A T I O N, O P E R A T I O N, M A I N T E N A N C E M A N U A L UVR SERIES ULTRAVIOLET WATER TREATMENT SYSTEM S a f e W a t e r T e c h n o l o g i e s, I n c. I N S T A L L A T I O N, O P E R A T I O N, M A I N T E N A N C E M A N U A L UVR SERIES ULTRAVIOLET WATER TREATMENT SYSTEM UVR04 MODELS: 4 GPM, 1/2 INCH

More information

Ultraviolet (UV) Disinfection System Model RC8

Ultraviolet (UV) Disinfection System Model RC8 Ultraviolet (UV) Disinfection System Model RC8 INSTALLATION & OPERATION MANUAL (Please save for future reference) System tested and certified by CSA International to NSF/ANSI Standard 55 for disinfection

More information

Owner s Manual. DO NOT REMOVE FROM UNIT See back cover for vital records

Owner s Manual. DO NOT REMOVE FROM UNIT See back cover for vital records Owner s Manual DO NOT REMOVE FROM UNIT See back cover for vital records ELECTRICAL SAFETY GROUNDING This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least

More information

375 Marcus Boulevard Hauppauge, NY USA Fax: Extensive Product Information Available at:

375 Marcus Boulevard Hauppauge, NY USA Fax: Extensive Product Information Available at: 375 Marcus Boulevard Hauppauge, NY 11788 USA 631.273.0500 Fax: 631.273.0771 e-mail: info@ultraviolet.com Extensive Product Information Available at: www.ultraviolet.com Document No. 98-1140A3 Revised August

More information

HydroRite UVO 3. Troubleshooting Guide Residential. TSG-UVO158a. Copyright 2015 Hayward Industries Inc.

HydroRite UVO 3. Troubleshooting Guide Residential. TSG-UVO158a. Copyright 2015 Hayward Industries Inc. HydroRite UVO 3 Troubleshooting Guide Residential TSG-UVO158a Copyright 2015 Hayward Industries Inc. Safety Precautions Warning! When installing and using this electrical equipment, basic safety precautions

More information

INSTALLATION MANUAL & OWNER S GUIDE. Stainless Steel Ultraviolet Water Purification System

INSTALLATION MANUAL & OWNER S GUIDE. Stainless Steel Ultraviolet Water Purification System INSTALLATION MANUAL & OWNER S GUIDE Stainless Steel Ultraviolet Water Purification System UVSS-6 UVSS-10 UVSS-15 UVSS-6M UVSS-10M UVSS-15M #51975 Rev. 5/10 Specifications Item # Model# Flow Rate** Flow

More information

Ultraviolet Monitoring System. Part Numbers UV/MS-1 V3 UV/MS-2 V3. Installation And Operations Manual

Ultraviolet Monitoring System. Part Numbers UV/MS-1 V3 UV/MS-2 V3. Installation And Operations Manual Ultraviolet Monitoring System Part Numbers UV/MS-1 V3 UV/MS-2 V3 Installation And Operations Manual 2 System Description The Wyckomar UV Monitor measures true UV intensity at 254 nm, which is the effective

More information

Bio-Logic. Owner s Manual. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Ballast 120v 50/60 Hz

Bio-Logic. Owner s Manual. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Ballast 120v 50/60 Hz Bio-Logic ULTRAVIOLET WATER PURIFIERS Models Read and Follow All Safety Instructions. Save These Instructions. SINCE 1963 Manufacturers / Engineers / Sales / Service Germicidal Ultraviolet - Equipment

More information

Manuel Guide Lighting Fixtures

Manuel Guide Lighting Fixtures Manuel Guide Lighting Fixtures Models: DL-T2424, DL-T3639, DL-T4854 Please read these manuals in their entirety before using these products. Safety Instructions Important Safety Note: To guard against

More information

Ballast 230v 50/60Hz MIN B B MIN B B MIN B B

Ballast 230v 50/60Hz MIN B B MIN B B MIN B B ULTRAVIOLET WATER PURIFIERS Models Read and Follow All Safety Instructions. Save These Instructions. Extensive Product Information Available at: ultraviolet.com buyultraviolet.com Ballast 120v 50/60 Hz

More information

Installation & Operating Guide

Installation & Operating Guide 5-036 HOT WATER TANK Installation & Operating Guide Read all instructions thoroughly. Keep this guide for future reference. Proof of purchase is required for Warranty. Staple receipt or proof of purchase

More information

Installation and Maintenance Manual

Installation and Maintenance Manual Installation and Maintenance Manual Models: UV-1, UV-250, UV-700, UV-1200, UV-1500, UV-3000 and UV-5000 UV Purification Systems CAUTION - WARNING The ballast and all electrical connections MUST be mounted

More information

WEDECO DLR A SERIES ULTRAVIOLET WATER DISINFECTION UNIT INSTALLATION OPERATION AND MAINTENANCE MANUAL MODELS DLR-A SERIES NO'S

WEDECO DLR A SERIES ULTRAVIOLET WATER DISINFECTION UNIT INSTALLATION OPERATION AND MAINTENANCE MANUAL MODELS DLR-A SERIES NO'S INSTALLATION OPERATION AND MAINTENANCE MANUAL MODELS DLR-A WEDECO DLR A SERIES ULTRAVIOLET WATER DISINFECTION UNIT SERIES NO'S 1 2 4 Sold by: Manufactured by: WEDECO Ideal Horizons, Inc. 3520 Westinghouse

More information

SLT-Series Installation and maintenance instructions

SLT-Series Installation and maintenance instructions Installation and maintenance instructions MODELS UVG SLT1, UVG SLT2, UVG SLT30, UVG SLT40, UVG SLT75, UVG SLT80, UVG SLT125, UVG SLT172 ATTENTION: Please read this manual carefully and follow the instructions.

More information

Models 120v 50/60 Hz 230v 50/60Hz MIN B A MIN B A MIN B A

Models 120v 50/60 Hz 230v 50/60Hz MIN B A MIN B A MIN B A Ballast Ballast Models 120v 50/60 Hz 230v 50/60Hz MIN-1 10-0508B 10-0504A MIN-1.5 10-0508B 10-0504A MIN-3 10-0508B 10-0504A 375 Marcus Boulevard Hauppauge, NY 11788 USA 631.273.0500 Fax: 631.273.0771 e-mail:

More information

Customized Drinking Water

Customized Drinking Water Customized Drinking Water PURA Ultraviolet Disinfection Systems 55 PURA Gen 5 Residential Systems: Genesis H2O: Ultraviolet Disinfection System A Security System For Your Water UV technology provides additional

More information

Owner s Manual. Installation, Operation and Maintenance. SPV-200, SPV-410, spv-600, spv-740, spv-950

Owner s Manual. Installation, Operation and Maintenance. SPV-200, SPV-410, spv-600, spv-740, spv-950 IMPORTANT NOTICE This card must be returned within (10) days of purchase or register your warranty on-line at www.viqua.com PLEASE PRINT Thank you. Model No. (Must Specify) Your Name: E-mail Address: DATE

More information

PRE INSTALLATION PROCEDURES

PRE INSTALLATION PROCEDURES PRE INSTALLATION PROCEDURES DANGER! ELECTRICAL SHOCK HAZARD. Only qualified personnel who have read and understand this entire manual should attempt to install, or service this WL250 Water Treatment System,

More information

GROWMAX WATER Perfect Water for Plants and Gardens

GROWMAX WATER Perfect Water for Plants and Gardens GROWMAX WATER Perfect Water for Plants and Gardens WATER SYSTEMS FOR HYDROPONICS AND GARDENING GROWMAX 3000 Ultra-Pure Reverse Osmosis Water System Up to 3000 L/D of Pure Water Don't forget to register

More information

SimplyClear Pressurized Filter Product Manual

SimplyClear Pressurized Filter Product Manual SimplyClear Pressurized Filter Product Manual For Model: SimplyClear 1250 (Item #130040) Table of Contents: Important Information... 2 Package Contents... 3 Technical Specs... 3 How it Works.................................

More information

INSTALLATION & MAINTENANCE

INSTALLATION & MAINTENANCE INSTALLATION & MAINTENANCE MODELS: UVG SLT 2 (GT7-2UVG) UVG SLT 30 (GT7-4UVG) UVG SLT 40 (GT7-8UVG) UVG SLT 75 (GT7-13UVG) UVG SLT80 UVG SLT125 (GT7-15UVG) and UVG SLT 172 Stainless Steel Water Disinfection

More information

Document No E1 Revised February Atlantic Ultraviolet Corporation

Document No E1 Revised February Atlantic Ultraviolet Corporation 375 Marcus Boulevard Hauppauge, NY 11788 USA 631.273.0500 Fax: 631.273.0771 e-mail: info@ultraviolet.com Extensive Product Information Available at: www.ultraviolet.com Document No. 98-1123E1 Revised February

More information

Instruction Sheet DANGER

Instruction Sheet DANGER VIQUA Lamp and Quartz Sleeve Replacement Models: D4, E4, F4, D4 Premium, Plus Models Discontinued Models: A, B, C, D, E, F, B4, C4 Overview UV Lamp replacement: The amount of UV light created by the UV

More information

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 1 IMPORTANT SAFETY INSTRUCTIONS Read the instructions The appliance is not to be used by persons (including children) with reduced physical, sensory

More information

Installation & Service Guide

Installation & Service Guide Reverse Osmosis Ontario Soft Water.ca Kitchener, Canada 519-579-0500 Installation & Service Guide Pentair 75 gpd Encapsulated Membrane System Standard System 75gpd Membrane Your New Reverse Osmosis System

More information

Ballast MIN A

Ballast MIN A Models Ballast 120v 50/60 Hz MIN-6 10-0508A 375 Marcus Boulevard Hauppauge, NY 11788 USA 631.273.0500 Fax: 631.273.0771 e-mail: info@ultraviolet.com Extensive Product Information Available at: www.ultraviolet.com

More information

(UV) - R830F & ) INTRODUCTION

(UV) - R830F & ) INTRODUCTION Ultraviolet (UV) Water Disinfection System Model - R830F (Includes Pre-Filter) Installation & Maintenance Instructions (Please save for future reference) INTRODUCTION Rainfresh water disinfection systems

More information

WL380 QUICK START GUIDE

WL380 QUICK START GUIDE WL380 QUICK START GUIDE WARNING! Only trained and qualified technicians should attempt to install, maintain, or service Waterlogic equipment. Failure to follow all instructions in this manual could result

More information

254 Nanometer Germicidal UV Disinfection Systems

254 Nanometer Germicidal UV Disinfection Systems For Commercial and Industrial Applications ES-PW-SmartStream-C _D Job Name Contractor Job Location Approval Engineer Contractor s P.O. No. Approval Representative 254 Nanometer Germicidal UV Disinfection

More information

PRE INSTALLATION PROCEDURES

PRE INSTALLATION PROCEDURES PRE INSTALLATION PROCEDURES DANGER! ELECTRICAL SHOCK HAZARD. Only qualified personnel who have read and understand this entire manual should attempt to install, or service this unit, failure to do so could

More information

Owner s Manual. Ultraviolet Water Purification System S80, SM80, SV50

Owner s Manual. Ultraviolet Water Purification System S80, SM80, SV50 Owner s Manual Ultraviolet Water Purification System S80, SM80, SV50 Congratulations. By purchasing this system, you have taken the first step in ensuring safe drinking water. Designed using the most advanced

More information

Owner s Manual. Model: Powered by. D4 Validated Models: D4-V _RevAC

Owner s Manual. Model: Powered by. D4 Validated Models: D4-V _RevAC Owner s Manual Model: D4 Validated Models: D4-V Powered by 45 Clair Rd. W, Guelph, Ontario, Canada NL R t. (+) 59.763.03 tf. (+) 800.65.746 (US and Canada only) t. (+3) 73 747 044 (Europe only) f. (+)

More information

Owner s Manual. Installation, Operation & Maintenance. Models S17A, S23A, S37C & S50C U LTRAVIOLET WATER PURIFIERS

Owner s Manual. Installation, Operation & Maintenance. Models S17A, S23A, S37C & S50C U LTRAVIOLET WATER PURIFIERS U LTRAVIOLET WATER PURIFIERS Models S17A, S23A, S37C & S50C Read and Follow All Safety Instructions. Save These Instructions. SINCE 1963 Manufacturers / Engineers / Sales / Service Germicidal Ultraviolet

More information

Operation & Installation Instructions

Operation & Installation Instructions Operation & Installation Instructions PUV-200 Series PUV-HO-200 Series PUV-300 Series PUV-HO-300 Series PULSAR - Standard Systems System Rated Flow System Rated Flow 405-PUV-100-02 405-PUV-200-02 405-PUV-300-02

More information

OWNER S MANUAL Operation & Installation Instructions

OWNER S MANUAL Operation & Installation Instructions OWNER S MANUAL Operation & Installation Instructions GEN5-8R12 GENH4-13R22 AQUA FLO- Rack-Mount Systems System Rated Flow Sediment Carbon GEN4-8R1 GEN5-8R1 GEN4-8R12 GEN5-8R12 GENH4-8R1 GENH5-8R1 GENH4-8R12

More information

Instruction Sheet DANGER

Instruction Sheet DANGER VIQUA Lamp and Quartz Sleeve Replacement Models: D4, E4, F4, D4 Premium, Plus Models Discontinued Models: A, B, C, D, E, F, B4, C4 Overview UV Lamp replacement: The amount of UV light created by the UV

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Product Preservers Anti-Scale System Chemical-Free, Salt-Free Scale Prevention Introduction The Product Preservers Anti-Scale System will condition the tap

More information

Owner s Manual. Ultraviolet Water Purification System. Pro Series (Pro10, Pro20 & Pro30) Plus Series (G+, H+, J+) Basic Series (G, H, J)

Owner s Manual. Ultraviolet Water Purification System. Pro Series (Pro10, Pro20 & Pro30) Plus Series (G+, H+, J+) Basic Series (G, H, J) Owner s Manual Ultraviolet Water Purification System Pro Series (Pro0, Pro0 & Pro30) Plus Series (G+, H+, J+) Basic Series (G, H, J) Congratulations. By purchasing this system, you have taken the first

More information

S-Series. Protect your water from pathogens and disease with the UV-Guard S-Series. Protect:

S-Series. Protect your water from pathogens and disease with the UV-Guard S-Series. Protect: UVG S440 MW UVG S160, S245 UVG S75, S40-76 S-Series Protect your water from pathogens and disease with the UV-Guard S-Series. The S-Series is a robust and dependable UV disinfection system able to provide

More information

UV Lamp and Quartz Sleeve Replacement/Maintenance

UV Lamp and Quartz Sleeve Replacement/Maintenance UV Lamp and Quartz Sleeve Replacement/Maintenance Models: Tap, Tap Plus, Home, Home Plus, Professional, Professional Plus (Excluding, D4, E4, F4, and Plus and Monitored versions) Overview UV Lamp replacement:

More information

K Specifications. Max. Water Volume

K Specifications. Max. Water Volume K 2.35 High Pressure Washer Operator Manual Overview... 2 Precautions... 2-4 Assembly Instructions... 4 Operating Instructions... 5 Using the Accessories... 6 Working with Detergents... 7 Shut Down and

More information

K Specifications. Max. Water Volume

K Specifications. Max. Water Volume K 2.75 High Pressure Washer Operator Manual Overview... 2 Precautions... 2-4 Assembly Instructions... 4 Operating Instructions... 5 Using the Accessories... 6 Working with Detergents... 7 Shut Down and

More information

A measured step forward

A measured step forward A measured step forward Operations & Maintenance Manual TM JESCO UV 405-412-440-450-480-550-80 2 LCD LCD PLUS Contents 1. Introduction...3 2. General Principles and Safety Instructions...4 3. Instructions

More information

Owner s Manual. Installation, Operation & Maintenance. Models S2400C, S5000C, S15000C, S20000C & S25,000C High Capacity Systems

Owner s Manual. Installation, Operation & Maintenance. Models S2400C, S5000C, S15000C, S20000C & S25,000C High Capacity Systems U LTRAVIOLET WATER PURIFIERS Models S2400C, S5000C, S15000C, S20000C & S25,000C High Capacity Systems Read and Follow All Safety Instructions. Save These Instructions. SINCE 1963 Manufacturers / Engineers

More information

J-PRO V 230V Dual Voltage Chlorinator Installation & Start-Up Guide

J-PRO V 230V Dual Voltage Chlorinator Installation & Start-Up Guide J-PRO-22 110V 230V Dual Voltage Chlorinator Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance, your system will be providing

More information

Owner s Manual. Installation, Operation and Maintenance. SC200-DWS11, SCm200-DWS11. Manufactured in Canada by:

Owner s Manual. Installation, Operation and Maintenance. SC200-DWS11, SCm200-DWS11. Manufactured in Canada by: Installation, Operation and Maintenance Owner s Manual Manufactured in Canada by: SC200-DWS11, SCm200-DWS11 SC320-dws12, SC320-dws22, SCm320-dws12, SCm320-dws22 425 Clair Road West P.O. Box 1719 Guelph,

More information

REGISTERED HANDBOOK. Document: ECN: Revision: C. MANUAL, O&M TrojanUVLogic TM System Systems Without Wiper AM, VM & TM Models

REGISTERED HANDBOOK. Document: ECN: Revision: C. MANUAL, O&M TrojanUVLogic TM System Systems Without Wiper AM, VM & TM Models REGISTERED HANDBOOK Document: 793612 ECN: 03-1884 Revision: C Checked by: OR_ Approved by: DK Date: 03DE08 Date: 03DE08 MANUAL, O&M TrojanUVLogic TM System Systems Without Wiper AM, VM & TM Models TROJAN

More information

Operation & Installation Instructions

Operation & Installation Instructions OWNERS MANUAL Operation & Installation Instructions LB4-031/2, LB4-061/2, LB4-101/2, LB4-201/2, LB5-031/2, LB5-061/2, LB5-101/2, LB5-201/2, LB6-061/2, LB6-101/2, LB6-201/2 illuminating technologies for

More information

SERVICE REQUIREMENTS

SERVICE REQUIREMENTS SERVICE REQUIREMENTS WARNING! Read and understand the contents of this manual before attempting to service WL270 Water Treatment System. Failure to follow the instructions in this manual could result in

More information

OWNERS MANUAL. Operation & Installation Instructions.

OWNERS MANUAL. Operation & Installation Instructions. OWNERS MANUAL Operation & Installation Instructions www.chandlersystemsinc.com Congratulations on purchasing this ultraviolet disinfection system. By purchasing a CHANDLER UV Disinfection system you are

More information

OWNERS MANUAL. Operation & Installation Instructions

OWNERS MANUAL. Operation & Installation Instructions OWNERS MANUAL Operation & Installation Instructions Revision #: 1 Date: July 2015 Congratulations on purchasing this ultraviolet disinfection system. By purchasing an PURA UV Disinfection system you are

More information

Installation & operating manual. Swimming pool water. UV disinfection device UV10+

Installation & operating manual. Swimming pool water. UV disinfection device UV10+ Installation & operating manual Swimming pool water UV10+ WARNING: UV-C radiation damages eyes and skin. Avoid direct radiation 2013 V2.5 www.vanremmen.nl Page 2 of 2 Contents 1. GENERAL... 4 2. WHAT IS

More information

Model K 520 M Part No

Model K 520 M Part No Model K 520 M Part No. 1.069-680.0 High Pressure Washer Operator Manual Overview... 2 Precautions... 2-4 Assembly Instructions... 4 Operating Instructions... 5 Using the Accessories... 6 Working with Detergents...

More information

Owner s Manual MIGHTY PURE. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Models MP16A, MP22A, MP36C & MP49C

Owner s Manual MIGHTY PURE. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Models MP16A, MP22A, MP36C & MP49C MIGHTY PURE ULTRAVIOLET WATER PURIFIERS Models MP16A, MP22A, MP36C & MP49C Read and Follow All Safety Instructions. Save These Instructions. SINCE 1963 Manufacturers / Engineers / Sales / Service Germicidal

More information

HOW YOUR UV DISINFECTION WORKS

HOW YOUR UV DISINFECTION WORKS Ultraviolet (UV) Water Disinfection System Model - R1245 Installation & Maintenance Instructions ( Please save for future reference) INTRODUCTION Rainfresh water disinfection systems utilize the proven

More information

S17A, S23A, S37C & S50C

S17A, S23A, S37C & S50C Models S17A, S23A, S37C & S50C Read and Follow All Safety Instructions. Save These Instructions. Extensive Product Information Available at: ultraviolet.com buyultraviolet.com Document No. 98-1377E2 May

More information

ALL-IN-ONE SF PF312 MAR PMAX All-In-One Instructions.indd 1 3/1/2017 9:20 AM

ALL-IN-ONE SF PF312 MAR PMAX All-In-One Instructions.indd 1 3/1/2017 9:20 AM ALL-IN-ONE SF650 MAR 2017 PMAX All-In-One Instructions.indd 1 888.868.1185 sales@pondmax.com www.pondmax.com 23PF312 3/1/2017 9:20 AM Frequency Cable Length Outlet Ø (Inch) 60 Hz 115 Volt 57 Watts 13 Watt

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at

More information

PRF-RO Pentair Reverse Osmosis System Installation and Maintenance Manual SAFETY GUIDES THE BASIC REVERSE OSMOSIS SYSTEM. Tools and Materials Required

PRF-RO Pentair Reverse Osmosis System Installation and Maintenance Manual SAFETY GUIDES THE BASIC REVERSE OSMOSIS SYSTEM. Tools and Materials Required PRF-RO Pentair Reverse Osmosis System Installation and Maintenance Manual SAFETY GUIDES Read and follow all steps and guides carefully before installing and using your reverse osmosis system. Do not use

More information

ULTRAVIOLET WATER PURIFIERS

ULTRAVIOLET WATER PURIFIERS Models Sanitron S37C & Mighty Pure MP36C Designed for CE Compliance Extensive Product Information Available at: ultraviolet.com buyultraviolet.com ULTRAVIOLET WATER PURIFIERS ULTRAVIOLET WATER PURIFIERS

More information

Models S2400C, S5,000C S25,000C High Capacity Systems. Read and Follow All Safety Instructions. Save These Instructions.

Models S2400C, S5,000C S25,000C High Capacity Systems. Read and Follow All Safety Instructions. Save These Instructions. ULTRAVIOLET WATER PURIFIERS Models S2400C, S5,000C S25,000C High Capacity Systems Read and Follow All Safety Instructions. Save These Instructions. Installation, Operation & Maintenance Extensive Product

More information

Steril Air mobil. Owner s Manual. GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : Fax:

Steril Air mobil. Owner s Manual. GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : Fax: Steril Air mobil Owner s Manual GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : +90212 244 4401 Fax: +90212 251 7136 SAFETY WARNINGS All personnel should be alerted to the potential hazards

More information

OWNERS MANUAL. Operation & Installation Instructions. L12, L22, L41, L57, L79 (Standard Output) H38, H53, H95, H151 (High Output)

OWNERS MANUAL. Operation & Installation Instructions. L12, L22, L41, L57, L79 (Standard Output) H38, H53, H95, H151 (High Output) OWNERS MANUAL Operation & Installation Instructions L12, L22, L41, L57, L79 (Standard Output) H38, H53, H95, H151 (High Output) www.atlasuv.co.uk Congratulations on purchasing this ultraviolet disinfection

More information

ULTRAVIOLET WATER PURIFIERS

ULTRAVIOLET WATER PURIFIERS ULTRAVIOLET WATER PURIFIERS ULTRAVIOLET WATER PURIFIERS Models Sanitron S37C & Mighty Pure MP36C Designed for CE Compliance Extensive Product Information Available at: ultraviolet.com buyultraviolet.com

More information

SmartStream UV. Ultraviolet Water Disinfection System. Maximize Water Quality Without Chemicals. Watts.com

SmartStream UV. Ultraviolet Water Disinfection System. Maximize Water Quality Without Chemicals. Watts.com SmartStream UV Ultraviolet Water Disinfection System Maximize Water Quality Without Chemicals Watts.com Applications Breweries Food & Beverage Residential Water Fountains Be Sure About Your Water Quality

More information

Table of Contents. List of Figures

Table of Contents. List of Figures 1 P a g e Table of Contents Introduction. 3 Receiving....4 Description Model G3 & G4...5/6 Water Production Flow Chart...7 Positioning the Cooler...8 Water Cooler Connections..9 Feed Water Connection....10

More information

Owner's Manual. Models: 400-USUV-10, 400-USUV- 20, 400-USUV-30. Visit us online at Powered by

Owner's Manual. Models: 400-USUV-10, 400-USUV- 20, 400-USUV-30. Visit us online at  Powered by Owner's Manual Models: 400-USUV-0, 400-USUV- 0, 400-USUV-30 Visit us online at www.uswatersystems.com Powered by US Water Systems Corporate Office 09 Country Club Road Indianapolis, IN 4634 info@uswatersystems.com

More information

K 2.90 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

K 2.90 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS K 2.90 M High Pressure Washer Operator Manual Overview... 2 Important Precautions... 3-4 Assembly Instructions... 4 Operating Instructions... 5 GFCI Instructions... 6 Using the Accessories... 6 Working

More information

1 P a g e. G4 Counter Top OPERATION MANUAL

1 P a g e. G4 Counter Top OPERATION MANUAL 1 P a g e G4 Counter Top OPERATION MANUAL Table of Contents Introduction. 3 Receiving....4 Description Model G3 & G4...5/6 Water Production Flow Chart...7 Positioning the Cooler...8 Water Cooler Connections..9

More information

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here: DISHWASHER Models DW2432 and DW2432SS Installation Manual Write Serial Number (on inner door of unit) here: Felix Storch, Inc. Summit Appliance Division 770 Garrison Avenue Bronx, New York 10474 www.summitappliance.com

More information

* If the infiniti UV Water Treatment System has an S2 Starter, it is fully interchangeable with the UV Lamp with Glow Starter.

* If the infiniti UV Water Treatment System has an S2 Starter, it is fully interchangeable with the UV Lamp with Glow Starter. SERVICE REQUIREMENTS WARNING! Read and understand the contents of this manual before attempting to service infiniti UV Water Treatment System. Failure to follow the instructions in this manual could result

More information

NANO TECH UV-C DISINFECTION SYSTEM

NANO TECH UV-C DISINFECTION SYSTEM NANO TECH UV-C DISINFECTION SYSTEM USER GUIDE MODELS NT-UV16 NT-UV40 and NT-UV40-T NT-UV75 and NT-UV75-T NT-UV87-TO (Ozone) NT-UV130F and NT-UV130-TF TABLE OF CONTENTS 1. Safety warnings... 3 2. Introduction...

More information

Conduit ~15" Inlet. UV Sterilizer - Connection to Forcemain

Conduit ~15 Inlet. UV Sterilizer - Connection to Forcemain 6" Sch 40 PVC Housing Final Grade (slope to drain) Conduit ~15" Power Cord Length 25 (Standard Length) ~48" Outlet PVC Forcemain from Pump 40watt Disinfection Unit rated at: 60k microw/cm 2 @ 24gpm ~29"

More information

Owner s Manual. Healthy, clean and safe. Installation, Operation and Maintenance

Owner s Manual. Healthy, clean and safe.   Installation, Operation and Maintenance Printed in Canada. Copyright 2000 Trojan Technologies Inc. London, Ontario, Canada. No part of this manual may be reproduced, stored in a retrieval system, or transmitted in any form or by any means without

More information

Ultraviolet (UV) Monitoring System - Open Channel Horizontal Systems Operation and Maintenance Manual

Ultraviolet (UV) Monitoring System - Open Channel Horizontal Systems Operation and Maintenance Manual Ultraviolet (UV) Monitoring System - Open Channel Horizontal Systems Operation and Maintenance Manual System #: Applications: Systems: Components: EC Series Wastewater Channels UV Meter (analog), Electronics

More information

K 3.97 M. Specifications or visit our website: In USA call: Part No

K 3.97 M. Specifications or visit our website:   In USA call: Part No K 3.97 M High Pressure Washer Operator Manual Overview... 2 Precautions... 2-4 Assembly Instructions... 4-5 Operating Instructions... 5-6 GFCI Instructions... 6 Using the Accessories... 6 Working with

More information

Owner s Manual. Models: PUV -7 PUV -14

Owner s Manual. Models: PUV -7 PUV -14 Owner s Manual Models: PUV -7 PUV -4 Congratulations. By purchasing this system, you have taken the first step in ensuring safe drinking water. Designed using the most advanced UV technology available

More information

AllClear G2 Series Pressurized Filters Product Manual

AllClear G2 Series Pressurized Filters Product Manual AllClear G2 Series Pressurized Filters Product Manual For Models: AllClear G2 2000 (Item #130050) AllClear G2 3500 (Item #130051) AllClear G2 4500 (Item #130052) AllClear G2 4500 AllClear G2 3500 Table

More information

J-PRO-22 Pump Proportional Feed Chlorinator Installation & Start-Up Guide

J-PRO-22 Pump Proportional Feed Chlorinator Installation & Start-Up Guide J-PRO-22 Pump Proportional Feed Chlorinator Installation & Start-Up Guide Thank you for purchasing a Clean Water System! Please review this start-up guide entirely before beginning to install your system

More information