OJ Waterline control system

Size: px
Start display at page:

Download "OJ Waterline control system"

Transcription

1 OJ Waterline control system THERMOSTATS FOR COMFORT HEATING AND SNOW MELTING Product presentation

2 Mk3 It s all about Room Temperature Control! The essential main goals are: Comfort Flexibility Reliability Energy & Cost efficiency

3 Mk3 To meet these essentials, OJ Electronics has developed The OJ Waterline Control System! Also called WLM3..and what does this system offer?

4 Mk3 A control system engineered for hydronic under floor heating & cooling. Designed for residential and commercial applications (Possible networking of Masters for large installations). Easy and quick installation (Using plug-in terminals and easy accessible screw terminals). High comfort with minimal energy consumption. Intelligent control for optimal operation with long life. Combines Under Floor Heating & Cooling control.

5 Mk 3 And how does it look? 130 mm

6 Control with Wireless and 2-Wired Bus System How to connect THERMOSTATS FOR COMFORT HEATING AND SNOW MELTING Product presentation: Part 1

7 The 2-Wired System Safe voltage! The 2-wire system is based on a 5 Volt low voltage communication bus, and is perfectly safe for end users under all conditions Master 8 outputs AO-module 6 outputs Easy wiring of Room Sensors/Controllers with standard cable (as BUS), from 2x0.25 up to 2x1.5 mm 2, length up to 300 m. Can also be wired in star.

8 The 2-Wired System Easy to add an extra Room Sensor/Controllerwith the standard 2-wire cable. Master 8 outputs AO-module 6 outputs

9 The Wireless System Remote Receiver for optimum position for radio signals. (more than one can be used) Up to 20 wireless thermostats can be added per 1 receiver Same type Masteris used for both the 2-Wired and the Wireless system. Easy to combine the 2-Wired and the Wireless system in same application. Master 8 outputs AO-module 6 outputs

10 Universal Master For Wireless & 2-Wired Bus System THERMOSTATS FOR COMFORT HEATING AND SNOW MELTING Product presentation: Part 2

11 WLM2 features part2 OJ Waterline Control System Features Master with eight outputs (for thermal actuators) Add On module with additional six outputs. Networking of Masters (Adds support for large installations with up to 1890 rooms) Double output terminals for up to 14 thermal actuators (ensures easy connection of more loops to the same channel output) Easy interconnections (RJ14 connectors like telephone plugs - for quick connection of Add On module and Receiver to enable wireless operation) Output for motorized 0-10V DC mixing valve.(available on FS Master Only) (Enables control of supply water temperature)

12 WLM2 features OJ Waterline Control System Features Supports Radiator zones. Room sensors and controllers are designed for easy mounting and battery replacement. Temperature on time. (Adaptive function ensures the desired temperature on time) Advanced Cooling features (Dew point protection through optional humidity sensors prevents condensation on floors) Humidity Sensor (RH) combined with air sensor(room thermostat) creates dew point value. The OJ controller ensures protection of the floor by controlling to 3 degrees before dew point. Support for Domestic Hot water. Optional interface for Building Management Systems (BMS) Compatibility with Home Automation Systems

13 Universal Masters Universal Masters For Wired and Wireless systems 8 Actuator Outputs Pump & Boiler control AO module for extension of outputs. 6 Actuator Outputs Connection of Room Sensors/Controllers Wired and Wireless Room sensors & controllers can be connected to the same Master. Wireless function Connection of one or more receivers. Exercise function To optimise lifetime of valves and pumps, these will be exercised every 72 hours during inactive periods.

14 The Master program Product Outputs 8 Standard Master 8 Digital Master 6 AO-module Supply voltage 230 V 230 V 230 V Output 230V WLM2-1BA WLM2-1FS WLM2-1AO Output 24V WLM2-3BA WLM2-3FS WLM2-3AO Control of mixing valve No Yes, delivery incl. sensor Weather compensation No Yes, with Outdoor module type WLOC Temperature settings Fixed Factory settings Default settings User settings Comfort temperature 21ºC 21ºC +5/+40ºC Setback temperature 18ºC 18ºC +5/+40ºC Min. limitation 17ºC 17ºC +10/+30ºC Max. limitation 27ºC 27ºC +10/+40ºC Frost protection 5ºC 5ºC +3/+8ºC

15 Digital Master with display Displaywith symbols and read-out of settings of temperatures Setting buttons 4 LED s & Symbols Supply voltage & Setback temp. X -Main Pump (depends on configuration) Secondary pump Boiler 8 LED s for outputs to Thermal Actuators

16 Digital Master: Setting of temperatures Symbol Setting of room temperatures: Comfort Setback Frost Setting of floor sensor: Max. Limitation Default 21ºC 18ºC 5ºC 27ºC Scale +5/+40ºC +5/+40ºC +3/+8ºC +20/+40ºC Min. Limitation 17ºC +10/+30ºC

17 Digital Master: Weather Compensation Symbol Default Scale Max. temperature of hot-water supply Setting of WINTER operation: Outdoor temperature 55ºC -3ºC +25/+85ºC -20/+10ºC *Temperature of hot-water supply Setting of SUMMER operation: Outdoor temperature 45ºC 25ºC +30/+70ºC +10/+35ºC *Temperature of hot-water supply 30ºC +10/+40ºC *When an outdoor sensor is used, the actual target temperature will be adjusted automatically to compensate for the change in outdoor temperature.

18 Digital Master: Control of the operation Symbol e.g. Software version 3.3 Control of Room Sensor/Controller function: OK: Correct operation E1-E9: E9: Failure OK Room Sensor/Controller with failure C01-1U 1U-E1 Read-out of actual data: Outdoor temperature Actual temperature of supply water 2ºC 46 C *Target temperature temperature of the supply water Control signal 0-10V 0 for mixing valve By entering this menu it is possible to adjust the P & I settings of the valve action. *With mounting of outdoor sensor. 46 C 3.5V

19 Digital Master: Read out of temperatures *Room Sensors/Controllers: -- Room temperature -- Sensor/Controller incl. floor sensor: -- Room temperature Min. Limitation temperature Max. Limitation temperature Room temperature -- Symbol e.g ºC ºC 20ºC 27ºC 22ºC --

20 Room Sensor/ Room Controller Program THERMOSTATS FOR COMFORT HEATING AND SNOW MELTING Product presentation: Part 3

21 Room sensor/controller program WLTP Room Sensor Institution version Design & mounting: Classic design. WLTA Standard Room Sensor Surface wall mounting or to standard socket. Standard AAA battery, alarm for replacement(wireless System). Min. 20% heat if empty battery or defect Room Sensor/Controller. WLTM & WLTD Room Sensor with setting mode Control of temperature: WLCT2 Room Controller with build in clock functions PI-control for accurate & stable comfort. 2 or more sensors/controllers in large rooms for average temperature measuring. Room temperature adjustment ± 4 C. Floor limit sensor for min. or max. limitation. Automatic or manual setback temperature and frost protection.

22 Control of room temperature Traditional ON/OFF control Over and undershoots the room temperature meaning poor comfort and energy waste as an end user tends to increase the setpoint while feeling cold at the undershoot periods. Advanced PI-control No over and undershooting of temperature ensures high and stable temperature comfort with a minimum energy consumption 20.5 C OFF 20.0 C 19.5 C HEAT 100% ON

23 Room sensors/controllers incl. Floor Sensor The Air Sensor is for control of room temperature. Min. temperature limitation Gives a minimum surface temperature of the floor, even when the air temperature is above the set point. Recommended for tiled floors to ensure high comfort. The Floor limit Sensor with priority is for limitation of floor temperature. Max. temperature limitation Prevents too high temperatures damaging the floor material. Recommended as protection to wood floors.

24 Room Sensors - Settings & Functions Setting Mode Switch: Automatic operation according to a Room Controller or the timer input on the Master. Fixed comfort temperature (21 C). Fixed setback temperature (18 C). Fixed operation temperature (frost protection of 5 C). Setting of Room Temperature: Max. setting ±4 C preventing excessive adjustment.

25 Room Controller with built-in clock-function Automatic comfort and setback temperature. Adaptive function (optimum start) For control of room temperature and area. Pre-programmed 4 event timing, requires only actual time and day to be set. Programs can be changed. Floor limit sensor can be connected. Wake The day begins Out Time to leave Night Time to sleep Home Back from school and work

26 Room Controller with built-in clock-function Setting up areas with the room controller 1. Enter the Menu AREA in the WLCT2 Room Controller 2. Choose the channels (rooms) that should get the setpoint from this Room Controller, by setting the channel number to On Channel 1 (Room 1) Channel 2 (room 2)

27 Configuring the system THERMOSTATS FOR COMFORT HEATING AND SNOW MELTING Product presentation: Part 4

28 Setting of Channel Wired Sensors Channels A-E: (1 to 14) Setting of Room Sensor/Controller to activate the Thermal Actuator. Set the arrow to position 4, and the channel output 4 will be activated. These settings can and should be made before the system is powered up. Channel 0: Used with the WLCT2 room controller, for controlling heating areas from a central position. (The WLCT2 is not part of a room)

29 Configuration of the Wireless Sensors The Master into learning mode: Set the learning mode Dip 3 switch to ON Standard Master: The Output LED s will indicate the system is configuring. Digital Master: LEARNINGMODE will also be shown in the display. When a Room Sensor/Controller is present on a channel, the corresponding LED will be lit. Press Activating of the Sensors/Controllers: Room Sensors: Remove the front cover and push the little button approx. 2 sec until it gives a little beep. Room Controllers:Press the watch symbol approx. 2 sec until the display shows init. The Room Sensor/Controller will now transmit it s unique code and the system has been configured.

30 Setback Temperature & Area Control THERMOSTATS FOR COMFORT HEATING AND SNOW MELTING Product presentation: Part 5

31 Central Setback Temperature Mounted Room Sensors Master AO Module Timer for setback temperature Generic remote timer connected direct to the Master.

32 Central Area Control Room Controllers for central Area control (channel 0). A room controller can be set to channel 0 and mounted outside the area, but set to control a number of rooms within a group, or it can be used as a sensor for a specific room, but still set to control the other rooms within the group. Example of mounted Room Sensors Individueladjustment ±4 C of the room temperature.

33 Operation of Pumps & Boiler THERMOSTATS FOR COMFORT HEATING AND SNOW MELTING Product presentation: Part 6

34 Operation of Boiler & Pumps Thermal Actuators opens Time 0:00 Boiler Time 4:10 Main Pump Time 3:10 UFH Pump Time 3:00 The boilercan only start again 5 minutes after it has stopped. (max run time 12 times per hr) The pumpswill continue operate 60 sec after the boiler stops allowing flow to dissipate through the system, Advantages: No water pressure against closed valves. Only start up by larger heat demand. Filter out operations under 3½ minutes. Longer life time with good economy.

35 Operation with Weather Compensation Mixing valve Sensor Outdoor module Operation with Weather Compensation: Outdoor module creates water supply target temperature. The mixing valve will open 20% during start-up process. Residual hot primary water is used before the boiler will start. When the boiler starts the mixing valve operation is released.

36 Special features THERMOSTATS FOR COMFORT HEATING AND SNOW MELTING Product presentation: Part 7

37 Network functions In large buildings with multiple areas it is possible to use a master to create a network of multiple zones. Circulation pump control of each string String 2 A network master could be a Digital Master for centralized control of mixed supply water or a Basic Master where no mixing is required. WLM- BA/FS 2,1 WLM-AO WLM- BA/FS 2,2 WLM- BA/FS 2,3 Slave Masters can then be added to the network to create additional zones. Boiler String 1 Slave Masters controlling a common pump are connected as a string on the network system. Up to 15 strings, each of up to 9 masters, can be connected as a network. Switching between cooling and heating can be done via the Network Master using a single WLAC interface. WLM- BA/FS 0,0 WLM- BA/FS 1,1 WLM- BA/FS 1,2 WLM- BA/FS 1,3 Network communication cable ID-selectors on the Masters Have to be set in order to identify the master on the network

38 Cooling functions In addition to controlling heating, all WLM masters have the ability to control the system for cooling. String 1 A WLAC module is required for the master to know that cooling is required. WLM- BA/FS 2,1 WLM- BA/FS 2,2 WLM- BA/FS 2,3 By using the humidity sensor (WLH-19) the system limits the formation of condensation on floor surfaces due to high humidity. Energy source WLH Local attached humidity sensor for local dew point protection Humidity sensors are attached to each master, and in a network the worst case situation will control the water supply temperature. If cooling is being limited due to high humidity a dehumidifier can be enabled by a master. WLM- BA/FS 0,0 wlac Changeover module WLAC-19 for switching between heating and cooling When cooling is enabled the cooling set point will be pre-determined by the master and will override any settings in any clock thermostat to ensure optimum energy efficiency. Signal for cooling/heating changeover

39 BMS functions The BMS function: In buildings with a Building Management System, this system can communicate with the WLM2 system by using the versions with BMS interface. This enables full remote control to ensure optimal control and energy efficiency in the building. Main BMS features: Read & set all individual room & floor limit temperatures Read all masters in a WLM2 network through the WLM2 network master. Read out status of all outputs like pumps, boiler and actuators Read & set weather compensation values Override functions to support testing RTU MODBUS via RS485 Example 1: Building Management Computer communicating with a standalone WLM2 with BMS interface Example 2: Building Management Computer communicating with a network of WLM2 with BMS interface

40 Domestic Hot Water Control It is possible to control the domestic hot water temperature with a special clock thermostat to ensure optimum energy saving. A sensor from the thermostat measures the temperature in the storage cylinder. A zone valve is then controlled via the WLM master, which in turn activates the boiler on demand. The under floor heating pump will NOT be activated 2-Wired type WLCT2-19/HW Wireless type WLCT2-29/HW 29/HW Boiler Hot Water cylinder Special WLCT2-19/HW sensor to enable control of the Hot Water Temperature Hot Water Sensor Automatic day and night temperature. Only for Control of Domestic Hot Water cylinders. Pre-programmed, requires only actual day and time to be set. Programs can be changed. External Sensor must be connected. WLM- BA/FS

41 Radiator Control It is possible to control a radiator circuit room temperature with a special Room Controller to ensure optimum energy saving. The thermostat measures the temperature in the room, and a zone valve is then controlled via the WLM master, which in turn activates the boiler on demand. Boiler Radiator Special WLCT2-19/R or WLCT2-29/R controller to enable control of a Radiator zone 2-Wired type WLCT2-19/R Wireless type WLCT2-29/R 29/R Automatic comfort and setback temperature. Only controlof of zones heated by radiators. Pre-programmed, requires only actual time and day to be set. Programs can be changed. WLM- BA/FS

42 2 Stage Heating Control If there is a need for enabling a secondary heat source in a room (e.g. a backup electrical radiator), it is possible to use a special room controller that will control two separate outputs. Additional heat source in the room Special WLCT-19/2 or WLCT-29/2 controller to enable control of a 2 step zone The second output will be activated only if the temperature cannot be achieved within a preset time period and a programmed hysteresis. Boiler Stage 2 WLM- BA/FS Stage 1 Room with additional heat source

43 System Check System check: Correct operation of the system can be checked using a special Install Mode. This enables the installer to individually test and prove each output without the normal delays in the system. System check is enabled by setting the Masters DIP 1 switch to ON. While using the system check it is possible to activate and deactivate outputs by changing the temperature settings from minimum to maximum on the Room Sensors / Room Controllers.

44 Interconnection of WLM2 products Interconnections: For easy installation, interconnections between master modules, master and add on modules, and master and wireless receivers, are made by pre-wired plug in RJ14 connectors (like telephone plugs) For connecting the WLM2 add on modules to WLM2 masters, a plug in connector is provided with the add on module. A WLRC2 wireless receiver is also connected to a WLM2 master, using the plug in connector provided with the receiver. For connecting a WLM2 master to another master, a plug in connector kit is available (WLM-NET)

45 Resume of Main Features Resume of OJ Waterline main features: Advanced operation of Boiler, Pumps and Thermal Actuators for maximum energy saving and lifetime. Room Controllers with build in Clock for setback temperatures and Area Control. 2-wired Room Sensors/Controllers connected by low voltage BUS. Wired and Wireless Sensors/controllers can be used in combination. Possibility to add weather compensation Cooling functions can be added including humidity sensors for Dew point protection. Network functions for larger installations. Interface for BMS (from 1st of September 2009) Provision for radiator, Domestic Hot water and 2 stage control.

46 Mark 3 Thank you for your attention

47 WLM3 Hydronic Heating & Cooling Efficient and flexible OJ Electronics A/S 2010

WLM3 the 3 rd generation of the OJ Waterline TM Control Systems. Industry leading intelligence, control SLIDE OJ Electronics

WLM3 the 3 rd generation of the OJ Waterline TM Control Systems. Industry leading intelligence, control SLIDE OJ Electronics WLM3 the 3 rd generation of the OJ Waterline TM Control Systems Industry leading intelligence, control and operation SLIDE 1 Designed to deliver value for all. Benefits; Reliability - Fit and Forget Flexibility

More information

WLM2 WLTA WLTD WLTP WLCT2

WLM2 WLTA WLTD WLTP WLCT2 57640C 12/12 (MBC) User Manual WLM2 WLTA WLTD WLTP WLCT2 www.ojelectronics.com Congratulations Congratulations with you new control system for underfloor heating and cooling. The control system has been

More information

intelligent controls for hydronic floor heating

intelligent controls for hydronic floor heating intelligent controls for hydronic floor heating FLOOR HEATING HYDRONIC FLOOR HEATING ELECTRIC HVAC CONTROLS & POWER THERMOSTATS FOR HYDRONIC FLOOR HEATING PRODUCT CATALOGUE 2016 MASTER PROGRAMME, SUPPLY

More information

Product Catalogue. energyefficient hydronic. floor heating and cooling in one FLOOR HEATING HYDRONIC HVAC CONTROLS & POWER FLOOR HEATING ELECTRIC

Product Catalogue. energyefficient hydronic. floor heating and cooling in one FLOOR HEATING HYDRONIC HVAC CONTROLS & POWER FLOOR HEATING ELECTRIC energyefficient hydronic floor heating and cooling in one FLOOR HEATING HYDRONIC FLOOR HEATING ELECTRIC HVAC CONTROLS & POWER Product Catalogue CONTROLS FOR HYDRONIC FLOOR HEATING OJ WATERLINE SYSTEM The

More information

Enhance the performance of every system

Enhance the performance of every system professional controls for underfloor heating Enhance the performance of every system FLOOR HEATING HYDRONIC FLOOR HEATING ELECTRIC HVAC CONTROLS & POWER OJ Waterline 3 RD GENERATION WATERBASED UNDERFLOOR

More information

Roth Touchline. German quality since Quick and easy user manual 1/10

Roth Touchline. German quality since Quick and easy user manual 1/10 Roth Touchline Quick and easy user manual German quality since 197 1/10 230 V Pump N N L L 230 V 230 V 2 V 2 V c/o in %H c/o out c/o in Trafo out /TB in N L eco 2V CH 1 CH 2 CH 3 CH 2V 2V 2V 2V 2V Touchline,

More information

- Data Brochure Universal Reset Module 423

- Data Brochure Universal Reset Module 423 - Data Brochure Universal Reset Module 423 D 423 08/07 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in

More information

- Data Brochure Universal Reset Module 422

- Data Brochure Universal Reset Module 422 - Data Brochure Universal Reset Module 422 D 422 08/07 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in

More information

WLM2 Networking. WLM2 Networking O J W A T E R L I N E

WLM2 Networking. WLM2 Networking O J W A T E R L I N E Section 3 : Page UK 5.0 : 01.2009 WLM2 Networking O J W A T E R L I N E WLM2 Networking Introduction The WLM 2 system is capable of being used to create a control network for use with multiple zone UFH

More information

Installation & Operating Instructions

Installation & Operating Instructions FH-RT Wireless Room Thermostat FH-BU Wireless Base Unit Installation & Operating Instructions Specification Base unit (230 V) Order Code: Primary voltage: Secondary voltage: Outputs 1-6: Outputs 7-8: 088H011901

More information

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data. ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data. The RVA63 controller can be utilized to control the following system configurations via LPB communication. Equipment Required

More information

ECL Comfort 110, application 116

ECL Comfort 110, application 116 Operating Guide ECL Comfort 110, application 116 (valid as of software version 1.08) English version www.danfoss.com How to navigate? Adjust temperatures and values. Switch between menu lines. Select /

More information

Roth Touchline. German quality since User manual quick and easy guide 1/10

Roth Touchline. German quality since User manual quick and easy guide 1/10 Roth Touchline User manual quick and easy guide German quality since 97 /0 20 V Pump N N L L 20 V 20 V 2 V 2 V c/o in %H c/o out c/o in Trafo out /TB in N L eco CH CH 2 CH CH 2V 2V 2V 2V 2V 2V Touchline,

More information

C37. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C37. User's Guide. Installer's Guide *VI7CE602* *087R8070* *087R8070* *VI7CE602*

C37. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C37. User's Guide. Installer's Guide *VI7CE602* *087R8070* *087R8070* *VI7CE602* User's Guide VI.7C.E6.02 2005.09 C37 *VI7CE602* *087R8070* www.danfoss.com ECL Comfort User's Guide ECL Comfort Installer's Guide www.danfoss.com *087R8070* *VI7CE602* Mixing controller with ON / OFF controlled

More information

Model: Touch-RF. 1 Wireless Series

Model: Touch-RF. 1 Wireless Series Model: Touch-RF Model: Touch-RF 1 Wireless Series Table Of Contents Product Image 1 Locking the Keypad 18 Table of Contents 2 Temperature Control 19 What is a Programmable Room Thermostat? 3-4 Hot Water

More information

GIACOMINI UNDERFLOOR HEATING CONTROLS GUIDE

GIACOMINI UNDERFLOOR HEATING CONTROLS GUIDE GIACOMINI UNDERFLOOR HEATING CONTROLS GUIDE PAGE 2 DOCUMENT CONTENT COMPONENT OVERVIEW P4 BASIC CONTROLS INC. COMPARISON CHART P6 CHAPTERS INTERMEDIATE CONTROLS INC. COMPARISON CHART ADVANCED CONTROLS

More information

HEAT TROL ELITE SERIES HWE-Single Stage, HWE-MOV, HWE-Mulit Stage Hot Water Reset Control for Light Commercial and Residential Applications Provides q

HEAT TROL ELITE SERIES HWE-Single Stage, HWE-MOV, HWE-Mulit Stage Hot Water Reset Control for Light Commercial and Residential Applications Provides q SIGNAL REPEATER RC2100 WI-CON Wireless Heating Control for Steam and Hot Water Boilers No sensor wiring required Intelligent sensing algorithm saves energy Low limit control and alarm alert operator of

More information

Heating Control Danfoss Link & Connect Thermostats

Heating Control Danfoss Link & Connect Thermostats Heating Control Danfoss Link & Connect Thermostats www.heating.danfoss.com Table of Contents 1. Introduction 1.1 Segment... 3 1.2 Danfoss Eco programmable radiator thermostat... 3 1.3 Overview of units

More information

C62. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C62. User's Guide. Installer's Guide *VIKME102* *087R8091* *087R8091* *VIKME102*

C62. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C62. User's Guide. Installer's Guide *VIKME102* *087R8091* *087R8091* *VIKME102* User's Guide VI.KM.E1.02 2005.09 C62 *VIKME102* *087R8091* www.danfoss.com ECL Comfort User's Guide ECL Comfort Installer's Guide www.danfoss.com *087R8091* *VIKME102* Double mixing controller C62 VI.KM.E1.02

More information

C66. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C66. User's Guide. Installer's Guide. *vi7cc502* *087R8069* *087R8069* *vi7cc502*

C66. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C66. User's Guide. Installer's Guide. *vi7cc502* *087R8069* *087R8069* *vi7cc502* User's Guide VI.7C.C5.02 2005.09 C66 *vi7cc502* *087R8069* www.danfoss.com ECL Comfort User's Guide ECL Comfort Installer's Guide www.danfoss.com *087R8069* *vi7cc502* Mixing controller with PI controlled

More information

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502* User's Guide VI.7B.D5.02 2005.10 P20 *VI7BD502* *087R8014* www.danfoss.com ECL Comfort User's Guide ECL Comfort Installer's Guide www.danfoss.com *087R8014* *VI7BD502* Boiler controller P20 VI.7B.D5.02

More information

Hydronic & HVAC Control Systems

Hydronic & HVAC Control Systems tekmar 218 Full Line Catalog Hydronic & HVAC Control Systems HVAC Multi-Staging Alternative Energy Zoning Snow Melting Setpoint tekmarcontrols.com tekmarcontrols.com Better Design, Better Control, Better

More information

ECL Comfort 300 / V a.c. and 24 V a.c.

ECL Comfort 300 / V a.c. and 24 V a.c. Data sheet ECL Comfort 300 / 301 230 V a.c. and 24 V a.c. Application The ECL Comfort 300 / 301 is an electronic temperature controller which can be loaded with selected applications by means of an ECL

More information

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - TriMax prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

Installation Guide. ECL Comfort 210, application A Table of Contents

Installation Guide. ECL Comfort 210, application A Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 4 2.1 Before you start.....................................................

More information

Overview - Danfoss Link and living software versions

Overview - Danfoss Link and living software versions Danfoss Link CC Mk II (with minisd card) software 2.1.35 2.3.27 2.4.51 2.5.57 2.7.42 01-12-2010 The initial Danfoss Link CC software: Supports all features from the original Devilink software. New functionality

More information

4 in 1 Digital Thermostat Control

4 in 1 Digital Thermostat Control 4 in 1 Digital Thermostat Control Models: VS10W and VS10B INSTALLER / USER MANUAL Contents Contents Box contents Introduction Product Compliance System options overview Installation Parameter Settings

More information

ECL Comfort V a.c. and 24 V a.c.

ECL Comfort V a.c. and 24 V a.c. 230 V a.c. and 24 V a.c. Description and application In heating applications the can be integrated with the Danfoss Link solution via the DLG interface for use in single-family applications. The controller

More information

Digital Thermostat. Models: VS35W and VS35B INSTALLER / USER MANUAL

Digital Thermostat. Models: VS35W and VS35B INSTALLER / USER MANUAL Digital Thermostat Models: VS35W and VS35B INSTALLER / USER MANUAL Contents Contents Box Contents Introduction Product Compliance Installation User Guide Parameter Settings Installers Notes Warranty Icons

More information

ECL Comfort 110, application 130

ECL Comfort 110, application 130 Operating Guide ECL Comfort 110, application 130 (valid as of software version 1.08) English version www.danfoss.com How to navigate? Adjust temperatures and values. Switch between menu lines. Select /

More information

Weather compensated flow temperature control of heating and boiler systems

Weather compensated flow temperature control of heating and boiler systems Instructions ECL Comfort 110 Application 130 Weather compensated flow temperature control of heating and boiler systems User guide, Installation & Maintenance DH-SMT/DK VI.KT.G3.02 Danfoss 06/2008 How

More information

SYX660 Commissioning Guide V Page 1 of 55

SYX660 Commissioning Guide V Page 1 of 55 Page 1 of 55 Table of Contents 1. INTRODUCTION... 4 1.1 Important Information Regarding Product Safety... 5 1.2 Notes on Disposal... 5 1.3 INPUTS... 6 1.4 ANALOGUE OUTPUTS... 7 1.5 OUTPUTS... 7 1.6 WEB

More information

Digital Thermostat Models: VS30W and VS30B

Digital Thermostat Models: VS30W and VS30B it600 VS30W - VS30B Installer - User Manual 015_Layout 1 28.07.2014 10:28 Digital Thermostat Models: VS30W and VS30B INSTALLER / USER MANUAL it600 VS30W - VS30B Installer - User Manual 015_Layout 1 28.07.2014

More information

B-40/B-41 Modulating Temperature Controller

B-40/B-41 Modulating Temperature Controller INSTALLATION & OPERATING INSTRUCTIONS B-40/B-41 Modulating Temperature Controller For Raytherm Boilers & Water Heaters H2 514-4001 WH2 2100-4001 Catalog No. 5000.70 Effective: 12-21-11 Replaces: NEW P/N

More information

Contents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual:

Contents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual: Contents Box contents: Instruction Manual Instruction manual: Box contents Introduction Product compliance System options overview Installation Parameter settings Error codes User guide Installers notes

More information

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating TPOne-B Electronic Programmable Room Thermostat Danfoss Heating Installation Guide TPOne is an intelligent programmable heating control made easy. TPOne includes features which are designed to save energy.

More information

Better Design, Better Control, Better Systems.

Better Design, Better Control, Better Systems. Product Catalog Better Design, Better Control, Better Systems. At tekmar Control Systems, we believe the indoor comfort of a building depends on the performance of its heating, ventilating & air conditioning

More information

The ECL Comfort 110 is a universal 1-circuit controller for use in district heating substations and district heating systems as well as boilerbased

The ECL Comfort 110 is a universal 1-circuit controller for use in district heating substations and district heating systems as well as boilerbased Data sheet ECL Comfort 110 230 V a.c. and 24 V a.c. Description and application ECL Comfort 110 The ECL Comfort 110 is a universal 1-circuit controller for use in district heating substations and district

More information

prestige Control Application Supplement - ACVMax

prestige Control Application Supplement - ACVMax 2015-10 Prestige ACVMax Control Sup 12-14-15_ACVMax_Control 12/15/15 7:36 AM Page 1 prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory

More information

Heat Link. Technical Guide

Heat Link. Technical Guide Heat Link Stat Link Technical Guide Third Version, May 2011 1 Table of Contents Thermostatic Zones Defined...................................... 4 StatLink System Components.....................................

More information

Underfloor Heating and Cooling Controls RELIABLE, ENERGY EFFICIENT CONTROLS FEATURING UNIQUE

Underfloor Heating and Cooling Controls RELIABLE, ENERGY EFFICIENT CONTROLS FEATURING UNIQUE Underfloor Heating and Cooling Controls RELIABLE, ENERGY EFFICIENT CONTROLS FEATURING UNIQUE 110763_UPONOR_CONTROLS_BROCHURE_AW.indd 1 7/8/2013 12:04:56 AM Indoor Climate: Controls Auto Balance Technology

More information

- Data Brochure Boiler Control 274

- Data Brochure Boiler Control 274 - Data Brochure Boiler Control 274 274_D 03/17 The Boiler Control 274 operates up to four on/off boilers to provide outdoor reset operation, domestic hot water and setpoint operation with priority. When

More information

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252 AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252 USER OPERATION AND MAINTENANCE WARNING Risk of electrical shock. Can cause severe injury, property damage or death. Only

More information

Overview - Danfoss Link and living software versions

Overview - Danfoss Link and living software versions Danfoss Link CC Mk II (with minisd card) software 2.1.35 2.3.27 2.4.51 2.5.57 2.7.42 01-12-2010 The initial Danfoss Link CC software: Supports all features from the original Devilink software. New functionality

More information

Drayton Digistat +3RF

Drayton Digistat +3RF Drayton Digistat +3RF Programmable Room Thermostat Wireless 5-2 Day / 7 Day Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845

More information

Model: Slimline-RF. 1 Slimline Series

Model: Slimline-RF. 1 Slimline Series Model: Slimline-RF Model: Slimline-RF 1 Slimline Series Table of Contents Product Image 1 Holiday Programming 22 Table of Contents What is a Programmable Room Thermostat? 2 3-4 Setting the Hot Water Switching

More information

4 Wiring Brochure Wiring and

4 Wiring Brochure Wiring and - Brochure tekmarnet 4 Thermostat 544 D 544 06/05 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough In Wiring Rough-in 4 Wiring

More information

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - TriMax prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

Operating Guide. ECL Comfort 210 / 296 / 310, application A247 / A Table of Contents

Operating Guide. ECL Comfort 210 / 296 / 310, application A247 / A Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 6 2.1 Before you start.....................................................

More information

30 radiators from one central point. Simply smarter heating. living.danfoss.com. living by Danfoss heating control

30 radiators from one central point. Simply smarter heating. living.danfoss.com. living by Danfoss heating control living by Danfoss heating control Simply smarter heating Giving your customers the ultimate integrated heating experience has never been easier. With Danfoss Link each individual element, from floor heating

More information

Fingertip control, optimum efficiency, total comfort and clear reporting. warmafloor.co.uk

Fingertip control, optimum efficiency, total comfort and clear reporting. warmafloor.co.uk Fingertip control, optimum efficiency, total comfort and clear reporting warmafloor.co.uk 1 Contents Intelligent control. 3 The key to efficiency Key system features 4 and benefits 7 Touchscreen 5 Alarms

More information

ECL Comfort 210 / 296 / 310

ECL Comfort 210 / 296 / 310 User Guide ECL Comfort 210 / 296 / 310 English version www.danfoss.com Safety Note Necessary assembly, start-up, and maintenance work must be performed by qualified and authorized personnel only. 2 Danfoss

More information

EXcon zone control. Control for up to 4 individual zones _ fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

EXcon zone control. Control for up to 4 individual zones _ fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov 3005925_2018-02-05.fm EXcon zone control Control for up to 4 individual zones EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov Tel. +45 65 66 12 34 Fax +45 65 66 11 10 exhausto@exhausto.dk www.exhausto.dk OJ-Air2

More information

G a

G a G2474 74 319 0081 0 a en Installation Instructions Heating controllers RVP3... Installation Place of installation In a dry room, e.g. in the boiler room Mounting choices: Control cabinet (in the front,

More information

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz ST325TX Manual Version 008_Layout 1 16/05/2013 09:02 Page 1 ST32 ST S T325 32 25 5TX TX ST3 T3 325T 32 25TX ST T3 325 25TX ST S T32 25T TX TX ST325TX Digital Room ST325 T3 5 5TX T X Thermostat RXBC605

More information

Control Application. Supplement - ACVMax

Control Application. Supplement - ACVMax prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

RADIANT HEATING AND COOLING SYSTEMS CLIMATE CŎNTROL ZONING SYSTEM INSTALLATION GUIDE. Climate Cŏntrol Zoning System Installation Guide

RADIANT HEATING AND COOLING SYSTEMS CLIMATE CŎNTROL ZONING SYSTEM INSTALLATION GUIDE. Climate Cŏntrol Zoning System Installation Guide RADIANT HEATING AND COOLING SYSTEMS CLIMATE CŎNTROL ZONING SYSTEM INSTALLATION GUIDE Climate Cŏntrol Zoning System Installation Guide Uponor Climate Cŏntrol Zoning System Installation Guide Published by

More information

danfoss Heating Solutions 5

danfoss Heating Solutions 5 4. Technical settings...22 4.1 Deactivating automatic daylight saving time...22 4.2 Adjusting to radiator/room...23 4.3 Deactivating intelligent control...23 4.4 Technical specifications...24 5. Safety

More information

ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data.

ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data. ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data. The RVA 46 Zone Controller can only be used in conjunction with a RVA47 controlled boiler installation. The RVA46 controller

More information

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

RVL471 Heating and Domestic Hot Water Controller Basic Documentation RVL471 Heating and Domestic Hot Water Controller Basic Documentation Edition: 2.2 Controller series: C CE1P2524E 23.10.2002 Siemens Building Technologies HVAC Products 2/118 HVAC Products 23.10.2002 Contents

More information

Odyssey. issue 01c. system manual

Odyssey. issue 01c. system manual dyssey issue 01c system manual SYSTEM MANUAL Table of Contents Technical Specification 1 Summary of Features 2 General Description 3 Control ptions 4 Description of Main Features 5 Control Schemes 6 Installation

More information

Installation Guide. ECL Comfort 310, application A Table of Contents

Installation Guide. ECL Comfort 310, application A Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 5 2.1 Before you start.....................................................

More information

120+ Get your job done swiftly Easy selection of your application is the key. applications.

120+ Get your job done swiftly Easy selection of your application is the key. applications. Application guide for ECL Comfort controllers Get your job done swiftly Easy selection of your application is the key The ECL Comfort series offers an optimum range of electronic controllers for temperature

More information

N M AirControl AHU. Control manual

N M AirControl AHU. Control manual N 10.63 M 03-2016 AirControl AHU Control manual EN CONTENTS PAGE 1 - MONITORING AND CONTROL 2 1.1 The program 2 1.2 The HMI terminal 2 1.3 The controller 4 1.4 Description of the air handling units 4

More information

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1 Model TRO24T4XYZ1 Description The TRO24T4XYZ1 is a combination controller and thermostat. The VAV Thermostat Controller is designed for simple and accurate control of any variable air volume box in a number

More information

Watts Under Floor Multi-zone Controller User Manual

Watts Under Floor Multi-zone Controller User Manual Watts Under Floor Multi-zone Controller User Manual Master unit RF Timer The digital wall thermostat can also use a floor temperature sensor to control minimum and maximum floor temperature, as well as

More information

Service Manual Models: 1.0, 1.3, and 1.5

Service Manual Models: 1.0, 1.3, and 1.5 AWX2-SER_100160837_2000000360_Rev F Service Manual Models: 1.0, 1.3, and 1.5 LOW LEAD CONTENT WARNING This manual must only be used by a qualified heating installer / service technician. Read all instructions,

More information

One Product Numerous Applications Electronic Controllers for Heating, Cooling, Ventilation and Air Condition

One Product Numerous Applications Electronic Controllers for Heating, Cooling, Ventilation and Air Condition MAKING MODERN LIVING POSSIBLE One Product Numerous Applications Electronic ontrollers for Heating, ooling, Ventilation and Air ondition Electronic ontrollers from Danfoss: Only a Few Products for an Endless

More information

DAP III Zone Master User s Guide

DAP III Zone Master User s Guide DAP III Zone Master User s Guide Data Aire, Inc. 230 West BlueRidge Avenue Orange, California 92865 Document Number 600-000-788 March 2010 Revision 1.0 Document # 600-000-788 1 Overview The Data Aire DAP

More information

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat. ROOM THERMOSTAT SYSTEM Radio frequency controlled programmable room thermostat. LARGE RECEIVER: 24CDi, 26CDi Xtra, 28CDi, 35CDi Mk I and 35CDi Mk II SMALL RECEIVER: 24i Junior, 28i Junior and Si Mk II

More information

Manual for the integration in BMS/GTC

Manual for the integration in BMS/GTC Manual for the integration in BMS/GTC Communication parameters MODBUS RTU and BACNET COMMUNICATION UTBS PRO-REG Software Version 3.6 EN ÍNDEX 1. GENERALITIES...2 1.1. Introduction...2 1.2. signals types...2

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS COMFORT CONTROL CENTER 2 THERMOSTAT OPERATING INSTRUCTIONS PROGRAMMABLE THERMOSTAT MODEL 3314080.000 BLACK 3314080.015 WHITE USA SERVICE OFFICE Dometic Corporation 1120 North Main Street Elkhart, IN 46514

More information

ROOM THERMOSTATS KNX BASIC DOCUMENTATION

ROOM THERMOSTATS KNX BASIC DOCUMENTATION ROOM THERMOSTATS KNX BASIC DOCUMENTATION Contents 2 2 2 2 ABOUT THIS DOCUMENT Document use / request to the reader Target audience, prerequisites Glossary 59 59 60 62 63 HANDLING Mounting and installation

More information

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM Radio frequency controlled programmable room thermostat FOR GREENSTAR 25 HE and GREENSTAR 30 HE MODELS Hol Man Auto Day SIGNAL HEATING ON OVERRIDE

More information

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE Emerson Blue Wireless Comfort Interface - Homeowner User Guide Message to Homeowners Congratulations on choosing the Emerson Blue

More information

Self-learning Room Temperature Controller

Self-learning Room Temperature Controller 2 257 Self-learning Room emperature Controller 5 operating modes and menu selection via roller selector REV16 Mains-independent room temperature controller Straightforward, self-explanatory menu selection

More information

Quickheat 30 weather compensated boiler control

Quickheat 30 weather compensated boiler control Quickheat 0 weather compensated boiler control A compact and sophisticated heating controller The compact KM controller is designed for the control of fan assisted boilers with modulating burners. The

More information

Corrigo E. Second generation which contains all applications and languages

Corrigo E. Second generation which contains all applications and languages revision 05 2009 Corrigo E Second generation which contains all applications and languages The controllers in the Corrigo E series are intended for applications within heating, boiler and ventilation control

More information

Thermostat TP42H01 User Manual

Thermostat TP42H01 User Manual Thermostat TP42H01 User Manual 1 of 12 This brochure will provide you with the information you need to benefit the most from your HydroLogic thermostat. Please visit your product manufacturers website

More information

RF Programmable Room Thermostat User Instructions

RF Programmable Room Thermostat User Instructions ESRTP4RF RF Programmable Room Thermostat User Instructions Thank you for choosing ESi Controls. All our products are tested in the UK so we are confident this product will reach you in perfect condition

More information

C-Stat 17-ZW User Instructions

C-Stat 17-ZW User Instructions C-Stat 17-ZW User Instructions 7 Day Wireless Programmable Room Thermostat and ASR-ZW Receiver Programmable room thermostats are widely recognised as one of the best ways in which to control central heating.

More information

Control Panel Checklist

Control Panel Checklist Control Panel Checklist Versatronik -C Panel Checklist Option Selection for Control Panel Quotes Checklist Control Panel Checklist Section 1 General Information Customer name Phone number Fax number Email

More information

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER This manual must be left with owner and should be hung on or adjacent to the boiler for reference. US HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER MODELS CHS-85 through CHS-399 APPENDIX A CONTROLLER

More information

Heating and D.h.w. Controller RVL482 Basic Documentation

Heating and D.h.w. Controller RVL482 Basic Documentation Heating and D.h.w. Controller RVL482 Basic Documentation Edition: 1.0 Controller series: A CE1P2542en 20.05.2008 Building Technologies Siemens Switzerland Ltd Building Technologies Group International

More information

TERMO-Blok TERMO-Extra TERMO-Blok PTV

TERMO-Blok TERMO-Extra TERMO-Blok PTV ELECTRIC BOILERS FOR CENTRAL HEATING TERMO-Blok TERMO-Extra TERMO-Blok PTV Contents 1. Introduction... 1 1.1. Applicable documents... 1 1.2. Retention of documents... 1 1.3. Introduction... 1 1.4. Heating

More information

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

Dec Wirsbo CoSy Radio. Installation and Operating Instructions Dec. 2002 Wirsbo CoSy Radio Installation and Operating Instructions Contents 1. Overview... 3 2. Room thermostat... 3 2.1 Thermostat models... 3 2.2 Function... 4 2.3 Positioning... 4 2.4 Setting and limiting

More information

Instruction FH-CWP Thermostat

Instruction FH-CWP Thermostat Instruction FH-CWP Thermostat Index Instruction FH-CWP Thermostat 1. Functional Overview.......................... 3 2. Mounting..................................... 4 3. Installation....................................

More information

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL The SF-10 Temperature Control () is an efficient boiler operator with a digital LCD display with backlight, a boiler pump output, and an alarm. The

More information

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning G2524en Heating controller Installation Instructions RVL471 1 Installation 1.1 Place of installation In a dry room, e.g. the boiler room Mounting choices: In a control panel (on the inner wall or on a

More information

Uponor Smatrix Base/Base PRO INSTALLATION AND OPERATION MANUAL

Uponor Smatrix Base/Base PRO INSTALLATION AND OPERATION MANUAL Uponor Smatrix ase/ase P UK INSTLLTION ND OPERTION MNUL 11 2017 Table of contents 1 Copyright and disclaimer...4 2 Preface...5 2.1 Safety instructions...5 2.2 Correct disposal of this product (Waste Electrical

More information

CS027 User Instructions

CS027 User Instructions CS027 User Instructions Battery Powered 7 Day Programmable Room Thermostat Programmable room thermostats are widely recognised as one of the best ways in which to control central heating. The CS027 programmable

More information

Electronic Pellet Burner Controller NPBC-V3M

Electronic Pellet Burner Controller NPBC-V3M Electronic Pellet Burner Controller NPBC-V3M SOFTWARE VERSION 3.3a/3.2 page of 27 CHANGES IN THE USER MANUAL OR IN THE CONTROLLER'S SOFTWARE Version of the user manual Changes Page 2.2. The software version

More information

Automation System TROVIS 5400 Ventilation Controller TROVIS Mounting and Operating Instructions EB 5477 EN. Electronics from SAMSON

Automation System TROVIS 5400 Ventilation Controller TROVIS Mounting and Operating Instructions EB 5477 EN. Electronics from SAMSON Automation System TROVIS 5400 Ventilation Controller TROVIS 5477 ounting and Operating Instructions Electronics from SASON EB 5477 EN Firmware version 2.0x Edition April 2004 Disclaimer of liability Disclaimer

More information

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer Installation and interface must be performed by a qualified controls technician. IMPORTANT: THIS MANUAL CONTAINS INFORMATION REQUIRED FOR INSTALLATION, INTERFACE AND CONFIGURATION OF THIS EQUIPMENT. READ

More information

- Data Brochure tekmarnet 4 Thermostat 542e

- Data Brochure tekmarnet 4 Thermostat 542e - Data Brochure tekmarnet 4 Thermostat 542e D 542e 03/08 1 Information Brochure Choose controls to match application 2 Application Brochure Design your mechanical applications 3 Rough In Wiring Rough-in

More information

- Essay Control Functions and Benefits

- Essay Control Functions and Benefits - Essay Control Functions and Benefits E 005 07/01 A hydronic heating control system performs many complex and important functions. Each of these functions provide benefits that make the system comfortable,

More information

Natural Ventilation Controller with 24vDC drive NVC-1204

Natural Ventilation Controller with 24vDC drive NVC-1204 Natural Ventilation Controller with 24vDC drive NVC-1204 BACnet Enabled C-036 08/11 FEATURES > 24V DC supply > Native BACnet communications > Master/Slave grouping (shared information) > 3 x 0-10V outputs

More information

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH) USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH) Logic Heat H / Logic Max Heat H / Logic System S / Logic Max System S / Vogue System / Vogue Max System Contents Introduction...

More information

Field settings table [6.8.2] =... ID66F2. Applicable units *BLQ05CAV3 *DLQ05CAV3 *BLQ07CAV3 *DLQ07CAV3. Notes (*1) *B* (*2) *D* 1/8

Field settings table [6.8.2] =... ID66F2. Applicable units *BLQ05CAV3 *DLQ05CAV3 *BLQ07CAV3 *DLQ07CAV3. Notes (*1) *B* (*2) *D* 1/8 /8 [6.8.2] =... ID66F2 Applicable units *BLQ5CAV3 *DLQ5CAV3 *BLQ7CAV3 *DLQ7CAV3 Notes (*) *B* (*2) *D* 2/8 User settings Preset values Room temperature 7.4.. Comfort (heating) R/W [3-7]~[3-6], step: A.3.2.4

More information

CONTENTS. Installation Guide. VT7200 Series

CONTENTS. Installation Guide. VT7200 Series VT7200 Series Installation Guide For mercial HVAC Applications November 2015 CONTENTS Installation 2 Location 2 Installation 2 Configurable BI/UI inputs overview 4 Network ready 6 Terminal, Identification

More information