... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant"

Transcription

1 ... Variante -4 as ired Unit eaters... rp 2018 rp Lot 21 Seasonal fficiency compliant

2 Variante 4... as ired Unit eaters... The new Variante 4 builds on the technical excellence of the previous range to provide cost effective and robust heating for industrial and commercial buildings. Using wall or roof mountings, the heaters are available for either room sealed or conventional power flue applications. Specification abinet ormed from electro-zinc plated sheet steel and painted epoxy pebble grey (RL 7032) to give a robust and durable finish. Louvres painted yellow olive (RL 6014) (VR Only) eat xchanger Tubular four-pass serpentine arrangement manufactured as standard from alumised steel with stainless steel option. Model Range There are 2 Variante ranges: > > VR axial fan > > VR centrifugal The Variante gas fired units are available with eleven heat outputs for use on natural gas (20) as standard, but alternatively can be specified for use on propane (31). VR heaters are fitted with axial fans and discharge warm air through a front outlet fitted with both horizontal and vertical louvers. Units can be turned through 90 0 and blow vertically downwards when using the rear mounted suspension points (not 120 & 145 models). urner In-shot burner type with automatic spark ignition and full safety flame proving. Modulating control is supplied as standard. Power Venter lue an Variante 4 are fitted with a powerful venter fan that enables exhaust & combustion air to be run up to a maximum of 9m each. VR heaters are fitted with direct drive centrifugal fans and discharge warm air via a duct spigot on the outlet (optional louvers are available for free-blowing applications). or applications requiring a ducted connection on the inlet, an optional blower cabinet is available which can also be fitted with filters with filters and a single inlet damper if required. ll Variante models are fitted with a modulating burner as standard, which requires a 0 to 10v signal to operate.

3 Options > > Top flue outlet (VR) > > Stainless steel heat exchanger > > 30deg or 60deg downflow heads > > Wall brackets (VR) > > estratification thermostat > > lower cabinet* > > ilters* *VR models only as fired unit heaters... VR VR complete with duct spigot outlet VR complete with optional blower cabinet lectric Motors ll electric motors are rp compliant where necessary. fficiency ach heater within the Variante range has been designed and developed with fuel efficiency in mind with efficiencies exceeding the mandatory requirements of building regulations. uel eaters are supplied for use with natural gas (20) as standard, however propane (31) is available upon request. Sealed ombustion ircuit Variante heaters are factory fitted with a power flue venter that enables the heater to be operated in either room sealed or fan assisted flue mode. The flue fan is safety interlocked with the burner control system via a pressure differential sensor. single phase electrical supply is required to each unit except the VR60 which is three phase. This supply should not be switched off except for maintenance

4 as fired unit heaters Versatile lue Installation The balanced flue terminal provides both the combustion air inlet and flue outlet from a single building penetration. The terminals are ordered separately from the heaters to suit either a wall outlet or roof outlet. dditional flue and combustion air pipes may be added, up to a maximum of nine metres of flue pipe, plus nine metres of combustion air pipe. (This reduces by 1.5 metres for every 90 bend fitted). Installation Units may be suspended or alternatively mounted on a suitable non-combustible support. Integral suspension points complete with an M10 female thread are provided to each heater. alanced flue wall outlet (type 12) eliminates expensive roof opening and flashing alanced flue roof outlet (type 32) single phase electrical supply is required to each unit except the VR60 which is three phase. This supply should not be switched off except for maintenance. Min 300 mm Units must not be installed in atmospheres containing flammable or explosive vapours, combustible dust, halogenated hydrocarbons or chlorinated vapours. They are also unsuitable for areas where contaminants may affect electrical motors or connections. ombustion air through wall, flue outlet through the roof (52) Separate combustion air and flue pipes (type 12) for applications where wall thickness exceeds maximum length shown in flue dimension table eater positions and flue arrangements illustrate VR models and are indicative only. or heater and flue clearances please refer to the appliance installation and maintenance instructions. Optimised ontrol To complement the Variante units the versatile Smartom MZ control panel is available > > Self adapting optimum start and stop > > asy set overtime and holiday periods Remote burner reset facility > > Password protection to prevent unauthorised adjustment > > Simple user friendly programming > > Individual seven day programming > > ay, night and frost (5 ) temperature settings > > Three on/off periods per day > > ours run and service data logging > > attery back up in the event of mains failure > > Modulating burner control Smartom MZ panel allows up to 16 panels to be linked for centralised control

5 as fired unit heaters VR VR Technical ata Nominal heat output irflow Temperature rise kw m 3 /h K Model , , , , as onnection Rc 1/2'' 3/4'' lectrical Supply V/ph/hz 230/240V 1N ~ 50z Total lectrical Rating W Mounting height(s) m , , , , , , Throw m as onsumption Natural gas 20 Propane 31 m 3 /h kg/h 1.27 N Maximum lue Run 9 Metres Noise level (1) d() Net weight kg , as consumption & outputs based upon natural gas 20 having a calorific value of 10.5kWh/ m3 V & Propane kWh/kg V Minimum gas inlet pressure is 17.5mbar for natural gas & 37mbar for Propane. Maximum inlet pressure is 50mbar. ir Inlet lue Outlet (1) Sound pressure level measured at 5m from the unit with =160m2 and Q=2 nlet emale). lue Outlet as onnection 2 mm. 1. lectrical onnections. 2. Service Panel. 3. Suspension Points (M10 emale). Tolerance ll imensions ± 2 mm. ction VR imensions Model Ref Unit Width Unit eight Unit epth Overall epth Suspension Points Suspension entres M10 emale lue Outlet & ir Inlet dia as connection Rc 1/2" 1/2" 1/2" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" learances (minimum) Top Rear of an ottom Non ccess Side ccess Side

6 as fired unit heaters VR VR Technical ata Nominal eat Output min static max static Min static pressure Max static pressure as onsumption Natural as 20 Propane 31 lectrical Supply kw Pa Pa kg/h V/ph/z Model /240V 1N ~ 50z /415V 3P ~ 50z /240V 1N ~ 50z lower lectrical Rating W Total lectrical Rating W Noise level d() Net Weight kg Min & max static pressure refers to external static pressure of ductwork (by others) as consumption & outputs based upon natural gas 20 having a calorific value of 10.5kWh/m3 V & Propane kWh/kg V Minimum gas inlet pressure is 17.5mbar for natural gas & 37mbar for Propane. Maximum inlet pressure is 50mbar. ir Inlet lue Outlet as onnection VR imensions Model Unit Width Unit eight Unit epth Overall epth Suspension Points M10 emale Suspension entres 550 lue Outlet & ir Inlet dia lectrical 130 onnections as onnection Rc 1/2" 1/2" 2. Service 3/4" Panel 3/4" 3/4" 3/4" uct Outlet Spigot learances (minimum) Top Rear of an ottom Non ccess Side ccess Side Suspension Points (M10 emale) (O): 533 Outher imensions Tolerance ll imensions ± 2 mm

7 as fired unit heaters VR with abinet VR with abinet Technical ata Nominal eat Output min static max static kw Model Max static pressure Pa as onsumption Natural as 20 Propane 31 lectrical Supply kg/h V/ph/z /240V 1N ~ 50z /415V 3P ~ 50z /240V 1N ~ 50z lower lectrical Rating W Total lectrical Rating W Net Weight kg Min & max static pressure refers to external static pressure of ductwork (by others) irflows & max static pressure quoted, exclude the use of optional filters and/or mixing dampers as consumption & outputs based upon natural gas 20 having a calorific value of 10.5kWh/ m3 V & Propane kWh/kg V Minimum gas inlet pressure is 17.5mbar for natural gas & 37mbar for Propane. Maximum inlet pressure is 50mbar. as onnection as onnection SIZ I J * * SIZ I 123 J ir Inlet lue Outlet as onnection * Optional inlet air damper Suspension VR Points with (M10 abinet emale) imensions lectrical onnections 3. as onnection Model ir Inlet lue Outlet (od) Outher imensions Tolerance ll imensions ± 2 mm Unit Width Suspension Points (M10 emale) 2. lectrical onnections Unit eight as onnection abinet epth (od) Outher imensions Tolerance ll imensions Overall epth ± 2 mm Suspension Points Suspension entres learances (minimum) Top Rear of an ottom Non ccess Side ccess Side M10 emale lue Outlet & ir Inlet dia as onnection Rc 1/2" 1/2" 3/4" ir Inlet 3/4" lue Outlet 3/4" 3/4" uct Outlet Spigot Suspension Points 502 (M10 emale) lectrical onnections 3. as onnection (od) Outher imensions Tolerance ll imensions ± 2 mm SIZ

8 NORTK LOL V (UK) LT ens Pool venue rierley ill West Midlands Y5 1Q United Kingdom /N/VR/007/1017 Tel: +44 (0) ax: +44 (0) Registered in ngland No Registered Office The olmore uilding, olmore ircus Queensway irmingham 4 6 Nortek lobal V is a registered trademark of Nortek lobal V Limited. ecause of continuous product innovation, Nortek lobal V reserves the right to change product specification without due notice.

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS BENSN... EnviroAir Gas Fired Heating, Ventilation & Cooling Units... AMBIRAD HEATI NG AND VENTILATIN S LUTINS EnviroAir... Gas Fired Heating, Ventilation & Cooling Units... The Benson EnviroAir is a new

More information

... UDSA - UDSBD Gas fired unit heaters...

... UDSA - UDSBD Gas fired unit heaters... UDSA - UDSBD Gas fired unit heaters UDSA with axial fan Reznor V3 unit heaters are one of the most technically advanced products available on the market today. Incorporating a radical new horizontal heat

More information

CP+ Gas & Oil Cabinet Heater Range

CP+ Gas & Oil Cabinet Heater Range CP+ Gas & Oil Cabinet Heater Range Industrial & Commercial Heating Systems. www.powrmatic.co.uk CP+ CP+EA External Heater HEATING // VENTILATION // AIR CONDITIONING // OEM PRODUCTS CP+ Overview Designed

More information

Heat Exchanger models

Heat Exchanger models Variante Sarto 3 Heat xchanger odels VR xial an or Models entrifugal an VR ownflow VR i-irectional Variante Introduction The copact highly effi cient enson Variante heaters provide cost effective heating

More information

Brute Elite Hydronic Boilers Indoor 285, ,000 BTU/Hr. 95+% Thermal Efficiency

Brute Elite Hydronic Boilers Indoor 285, ,000 BTU/Hr. 95+% Thermal Efficiency rute lite Hydronic oilers Indoor 285,000-850,000 TU/Hr. 95+% Thermal fficiency The unit will be designed and constructed in accordance with the SM oiler and Pressure Vessel ode Section IV requirements

More information

Knight & Charger Water Heaters

Knight & Charger Water Heaters Knight & harger Water eaters rom 127-1853 l/h recovery rate Storage capacities from 109-357 litres ast recovery water heater 3 Year Storage Vessel warranty onventional flued appliance as fired storage

More information

Gas-Fired Indoor and Outdoor Duct Furnaces

Gas-Fired Indoor and Outdoor Duct Furnaces July, 2008 Gas-Fired Indoor and Outdoor Duct Furnaces INDOOR GRAVITY VENTED DFG, DBG, DCG INDOOR SEPARATED COMBUSTION DFS, DBS, DCS OUTDOOR GRAVITY AND POWER EXHAUSTED H Series table of contents A complete

More information

P e l l e t S t o v e S P U R e P e R F o R M A N C e

P e l l e t S t o v e S P U R e P e R F o R M A N C e Pellet Stoves PUR PRORMN Proven Performance Powerful heating performance and easy operation make any Quadra-ire pellet stove a smart investment. Traditional craftsmanship and multiple finishing options

More information

OUH Suspended Oil Unit Heater Industrial & Commercial Heating Systems

OUH Suspended Oil Unit Heater Industrial & Commercial Heating Systems OU Suspended Oil Unit eater Industrial & Commercial eating Systems www.powrmatic.co.uk +44 (0) 1460 53535 info@powrmatic.co.uk rp RDY 2018 POWRMTIC PRODUCT INDUSTRIL & COMMRCIL WRM IR TIN SOLUTION INDUSTRIL

More information

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS THE UK'S ONLY NOx CLASS 6 RATED FLOOR STANDING BOILER IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING The Imax Xtra EL range of dual condensing boilers is available in 5 models with outputs from 715 to 1240kW.

More information

AMBIRAD.... Vision Radiant Tube Heating Systems...

AMBIRAD.... Vision Radiant Tube Heating Systems... AMBIRAD Vision Radiant Tube Heating Systems * Vision... Radiant Tube Heating Systems... Renowned for its pioneering track record, AmbiRad, Europes leading supplier of radiant tube heating systems, has

More information

Gas-Fired Indoor and Outdoor Duct Furnaces

Gas-Fired Indoor and Outdoor Duct Furnaces 5-173.3 January, 2005 Gas-Fired Indoor and Outdoor Duct Furnaces INDOOR GRAVITY VENTED DFG, DBG, DCG INDOOR SEPARATED COMBUSTION DFS, DBS, DCS OUTDOOR GRAVITY AND POWER EXHAUSTED H Series TABLE OF CONTENTS

More information

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance Installation Operation Commissioning Maintenance HOT AIR GENERATOR WITH GAS BURNER GGS NA11.45 A 06-2011 04-2011 CONTENTS 1. DESCRIPTION OF THE UNIT 2. INSTALLATION & CONNECTION 3. COMMISSIONING 4. CARE

More information

Winterwarm Agri UK. Winterwarm. Winterwarm heating solutions ... Winterwarm-quality. heating solutions

Winterwarm Agri UK. Winterwarm. Winterwarm heating solutions ... Winterwarm-quality. heating solutions Winterwarm Agri UK Winterwarm heating solutions Looking for an efficient heater for your glass house or your poultry house? Winterwarm offers various heating solutions for this purpose.........................................................................

More information

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F) UNIT HEATER CATALOG Form RZ-NA-C-UH (Version F) BACKGROUND Reznor was founded in 1888 to manufacture the Reznor reflector heater, which used a luminous flame gas burner developed by George Reznor. This

More information

SGS Condensing High Efficiency Gas-Solar Water Heater

SGS Condensing High Efficiency Gas-Solar Water Heater ondensing High Efficiency as-solar ater Heater - 8/0/0/0/80/100/10 Solar control Storage tank ully room-sealed condensing high efficiency gas-solar water heater Maximum solar contribution through fully

More information

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A cod. 6272262A GENERAL DATA Heating Data Heat Output Input (Adjustable) (Adjustable) Format 34i 11.2 34KW 45 145MJ/hr Format 34e 11.2 34KW 45 145MJ/hr General Specifications FORMAT 34i 34e Main burner injectors

More information

MODEL PVF INDIRECT GAS FIRED FURNACES FOR ENERGY RECOVERY UNITS Installation, Operation, and Maintenance Manual

MODEL PVF INDIRECT GAS FIRED FURNACES FOR ENERGY RECOVERY UNITS Installation, Operation, and Maintenance Manual RETIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Part # 461006 MODEL PVF INDIRECT GS FIRED FURNCES FOR ENERGY RECOVERY UNITS Installation, Operation, and Maintenance Manual Model PVF, Indirect Gas Furnace,

More information

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil UNIT HEATER CATALOG COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS FUEL Natural Gas Propane Fuel Oil CAPACITIES 25-1,200 MBH 80% - 93% Thermal Efficiency 380-16,750 CFM AIR DELIVERY Propeller

More information

SUBMITTAL SCHEDULE & DATA

SUBMITTAL SCHEDULE & DATA SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Job Name: Date: 10/31/2016 Location: Engineer: Submitted by: Jeff Musto Architect: Contractor: Model

More information

CTU Unit Heaters. Installation, Commissioning, Operation & Service Manual. Model CTU 22 to 115. Quality in Any Language Copyright 2003 Roberts-Gordon

CTU Unit Heaters. Installation, Commissioning, Operation & Service Manual. Model CTU 22 to 115. Quality in Any Language Copyright 2003 Roberts-Gordon FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Leave the building. 6. Immediately

More information

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces SG-UUH-03 November 2014 Specification Guide FSA, FOA, & HED Series Unit Heaters and Duct Furnaces Product improvement is a continuous process at Advanced Distributor Products. Therefore, product specifications

More information

Air Replacement Systems

Air Replacement Systems GLOL FINISHING SOLUTIONS ir Replacement Systems > Eliminate problems with drafts, stale or contaminated air, and temperature stratification > reate balanced building pressure and maintain proper comfort

More information

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh PRODUCT SPECIFICATIONS GAS UNIT HEATERS / DUCT FURNACES TU T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ Bulletin No. 20402 November 207 Supersedes November 206

More information

GAS AIR HEATER RANGE

GAS AIR HEATER RANGE GAS AIR HEATER RANGE ATH Horizontal gas air heater ATC Centrifugal gas air heater ATV Vertical gas air heater Address : Yahtec - 6 rue Pascal 7700 Meaux - France Phone number :+ (0) 60 4 4 86 Multiple

More information

NVx Suspended Gas Unit Heater

NVx Suspended Gas Unit Heater NVx Suspended as Unit Heater Industrial & Commercial Heating Systems www.powrmatic.co.uk +44 (0) 1460 53535 info@powrmatic.co.uk rp RADY 2018 POWRATIC PRODUCT INDUSTRIAL & CORCIAL & CORCIAL WAR HATIN AIR

More information

U n i t H e at e r s

U n i t H e at e r s Unit Heaters LF Models Enduring performance Allied commercial unit heaters are built to last, season after season Designed and built for durability and peak performance, Allied Commercial unit heaters

More information

RAYPAK HOT WATER & HEATING

RAYPAK HOT WATER & HEATING All copper & bronze construction On/Off & modulating models High temperature applications RAYPAK HOT WATER & HEATING Raypak is a compact, efficient heating design which is the ideal way to heat large quantities

More information

LUH HORIZONTAL FAN-FORCED UNIT HEATER

LUH HORIZONTAL FAN-FORCED UNIT HEATER LUH HORIZONTAL FAN-FORCED UNIT HEATER VERSATILE, FAN-FORCED HEATING FOR COMMERCIAL AND INDUSTRIAL COMFORT HEAT APPLICATIONS Horizontal airflow Wall or ceiling mounting Self-contained Totally enclosed fan

More information

VPC Gas Cabinet Heater Range

VPC Gas Cabinet Heater Range VPC Gas Cabinet Heater Range Industrial & Commercial Heating Systems www.powrmatic.co.uk +44 (0) 1460 53535 info@powrmatic.co.uk ErP READY 2018 POWRMATIC PRODUCT INDUSTRIA & COMMERCIA & COMMERCIA WARM

More information

NVS Condensing Gas Suspended Unit Heater

NVS Condensing Gas Suspended Unit Heater VS ondensing as Suspended Unit Heater Industrial & ommercial Heating Systems Energy Technology List AROVED RODUT www.powrmatic.co.uk +44 (0) 1460 53535 info@powrmatic.co.uk Er READY 2018 OWRATI RODUT IDUSTRIAL

More information

VENTING VENTING OF INDIRECT GAS FIRED AND OIL FIRED HEATING APPLIANCES INDOOR GRAVITY VENTED UNIT HEATERS AND PACKAGED SYSTEMS

VENTING VENTING OF INDIRECT GAS FIRED AND OIL FIRED HEATING APPLIANCES INDOOR GRAVITY VENTED UNIT HEATERS AND PACKAGED SYSTEMS APPLICATION BULLETIN FORM NO. RZ-T-V VENTING VENTING OF INDIRECT GAS FIRED AND OIL FIRED HEATING APPLIANCES The single most important factor in the installation and use of an indirect gas fired appliance

More information

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of

More information

Exhaust Duct Design Page 1 of (C)

Exhaust Duct Design Page 1 of (C) Exhaust Duct Design Page 1 of 16 2016-10-07 (C) Oven Exhaust Guide Version: R5 Exhaust Duct Design The following section is for your guidance in establishing a design to suit your Exhaust duct design requirements.

More information

Gas heaters and convectors ROBUR

Gas heaters and convectors ROBUR Gas heaters and convectors ROBUR Table of Contents Robur M general characteristic...3 Robur M dimensions...3 Robur M construction...4 Robur M technical data...5 Robur M installation...6 Robur M accessories...7

More information

Gas-Fired Unit Heaters Commercial & Industrial

Gas-Fired Unit Heaters Commercial & Industrial 6-107.10 February, 2005 Gas-Fired Unit Heaters Commercial & Industrial GRAVITY VENTED PD, BD POWER VENTED PDP, BDP, HD SEPARATED COMBUSTION PSH, BSH, HDS GAS-FIRED, GRAVITY-VENTED UNIT HEATERS Low Initial

More information

RS/UHC / UF RS/UHC-2 / 2UF

RS/UHC / UF RS/UHC-2 / 2UF Gas fired room sealed unit heaters centrifugal TECHNICAL INFORMATION, ASSEMBLY INSTRUCTIONS, USE AND MAINTENANCE RS/UHC / UF RS/UHC-2 / 2UF BENSON HEATING LUDLOW ROAD KNIGHTON POWYS, LD71LP U.K. August

More information

Heating Systems. An ideal temperature in every pig house

Heating Systems. An ideal temperature in every pig house Heating Systems An ideal temperature in every pig house Heating systems for ideal house temperatures Ideal house temperatures have a substantial influence on pig health and performance. Adequate heating

More information

True performance and rugged durability. TU, LF and LD Models

True performance and rugged durability. TU, LF and LD Models Unit heaters/ Duct furnaces True performance and rugged durability TU, LF and LD Models Separated Combustion Unit Heaters at a glance: Ideal for hard-to-heat applications requiring fresh air for combustion

More information

Combat. Compact Tubular Unit Heaters Installation, Commissioning, Operation & Service Manual Models CTCU 7 CTCU 11 CTCU 15 CTCU 22 CTCU 27 CTCU 32

Combat. Compact Tubular Unit Heaters Installation, Commissioning, Operation & Service Manual Models CTCU 7 CTCU 11 CTCU 15 CTCU 22 CTCU 27 CTCU 32 FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Extinguish any open flame. 6.

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

Product Catalog Gas Heating Products: Indoor and Outdoor Units

Product Catalog Gas Heating Products: Indoor and Outdoor Units Product Catalog Gas Heating Products: Indoor and Outdoor Units Indirect Fired, Direct Fired, and Gas Unit Heaters March 2017 UH-PRC004B-EN Copyright Thisdocumentand the informationinitare the propertyof

More information

2015 MECHANICAL CODE REQUIREMENTS

2015 MECHANICAL CODE REQUIREMENTS 2015 MECHANICAL CODE REQUIREMENTS ANTRIM COUNTY BUILDING DEPARTMENT PO BOX 188 205 CAYUGA STREET BELLAIRE, MI 49615 (231) 533-8373 FAX (231) 533-6041 Mechanical requirements for residential buildings per

More information

Innsbrook Traditional & Loft Contemporary Vent-Free Fireplace Inserts

Innsbrook Traditional & Loft Contemporary Vent-Free Fireplace Inserts Innsbrook Traditional & Loft ontemporary Vent-ree ireplace Inserts Innsbrook 28,000 tu Vent-ree ireplace Insert shown with optional 6 x 6-inch Metal Surround and rch Louvers in Hammered Pewter. White Mountain

More information

Gas Instantaneous Water Heater

Gas Instantaneous Water Heater 6 720 607 823 GB (06.06) SM Installation and Operating Instructions Gas Instantaneous Water Heater WR10..B... WR11..B... With electronic ignition and triple safety system consisting of ionisation detector,

More information

LAARS U.H.E. Ultra-High Efficiency Commercial Water Heaters

LAARS U.H.E. Ultra-High Efficiency Commercial Water Heaters LRS U... Ultra-igh fficiency ommercial Water eaters Ultra-igh fficiency Water eaters from Laars eating Systems ompany Laars U... is one of the most exceptional additions to the Laars eating Systems commercial

More information

INFRARED RADIANT HEATERS

INFRARED RADIANT HEATERS IRH-1R INFRARED RADIANT HEATERS High and Low Intensity RSU SERIES Unit is shown rotated at a 45 angle. RSD SERIES HIGH INTENSITY INFRARED HEATERS RSD Series Ceramic Heaters Special Honeycomb Tile Design

More information

Submittal Data Model AM Low Intensity Adaptive Modulating Infrared Heaters

Submittal Data Model AM Low Intensity Adaptive Modulating Infrared Heaters Submittal ata Model M ow Intensity daptive Modulating Infrared Heaters Project Engineer ontractor Model # ate: Submitted by: pproved by: General Specification Fuel Type (heck one) Natural Gas PG Heat Exchanger

More information

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG: 4YCC3060A-SPEC-1A TAG: SINGLE PACKAGED GAS HEATING ELECTRIC COOLING MODEL RATED Volts/PH/Hz Performance Cooling BTUH 1 Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr.) Sound Power Rating [db(a)]

More information

VIESMANN VITOCROSSAL 300 Gas condensing boiler 787 to 1400 kw

VIESMANN VITOCROSSAL 300 Gas condensing boiler 787 to 1400 kw VIESMANN VITOCROSSAL 300 Gas condensing boiler 787 to 1400 kw Datasheet Part no. and prices: see pricelist VITOCROSSAL 300 Type CR3B Gas condensing boiler for natural gas E, LL and LPG 9/2011 Benefits

More information

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You. TGIF- Indirect Fired Heating Systems Technical Guide for: IF Indoor Installations IFW Outdoor Installations Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide In the business of

More information

Take Charge of Your Commercial Water Heating with the New Commander Series from Bradford White Bradford White s Commander Series The Commander Series

Take Charge of Your Commercial Water Heating with the New Commander Series from Bradford White Bradford White s Commander Series The Commander Series Commander Series Ultra Low NOx Commercial Gas Water Heaters Take Charge of Your Commercial Water Heating with the New Commander Series from Bradford White Bradford White s Commander Series The Commander

More information

Wall Hung Condensing Boilers. Working towards a cleaner future. heating specialists

Wall Hung Condensing Boilers. Working towards a cleaner future. heating specialists Paramount two Wall Hung Condensing Boilers Working towards a cleaner future heating specialists Product Overview page 3 Introduction 4 Benefits System & Applications 5 System Requirements 5 Single Boiler

More information

UDSA-4. Gas fired Balanced flue / Fan assisted flue unit heater with BMBC burner relay INSTALLATION COMMISSIONING SERVICING

UDSA-4. Gas fired Balanced flue / Fan assisted flue unit heater with BMBC burner relay INSTALLATION COMMISSIONING SERVICING 1510UDSA-4BMBCGBEN UDSA-4 Gas fired Balanced flue / Fan assisted flue unit heater with BMBC burner relay INSTALLATION COMMISSIONING SERVICING These appliances meet the following EC Directives: DIR 2009/142/EC:GAD

More information

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F) UNIT HEATER CATALOG Form RZ-NA-C-UH (Version F) BACKGROUND Reznor was founded in 1888 to manufacture the Reznor reflector heater, which used a luminous flame gas burner developed by George Reznor. This

More information

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh GAS UNIT HEATERS / DUCT FURNACES LF24 COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ PRODUCT SPECIFICATIONS Bulletin 2008 July 206 Supersedes October 20 Steady-State Efficiency - up to 8% Input

More information

Blackheat. Vacuum Assisted Linear & U-Tube Gas Fired Radiant Heating Systems. Installation, Operation & Service Manual

Blackheat. Vacuum Assisted Linear & U-Tube Gas Fired Radiant Heating Systems. Installation, Operation & Service Manual FOR YOUR SFETY If you smell gas: 1. Open windows. 2. O NOT try to light any appliance. 3. O NOT use electrical switches. 4. O NOT use any telephone in your building. 5. Leave the building. 6. Immediately

More information

INDOOR/OUTDOOR, HOT WATER HEATERS AND HYDRONIC HEATING BOILERS

INDOOR/OUTDOOR, HOT WATER HEATERS AND HYDRONIC HEATING BOILERS LCD-5 INDOOR/OUTDOOR, HOT WATER HEATERS AND HYDRONIC HEATING BOILERS The LCD Dominator Series from RBI offers competitively-priced indoor/outdoor units that meet low NOx requirements, while maintaining

More information

EOLO B RT CONDENSING AND MODULATING ROOF-TOP GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

EOLO B RT CONDENSING AND MODULATING ROOF-TOP GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION EOLO B RT CONDENSING AND MODULATING ROOF-TOP GAS AIR HEATER AIR HEATING TECHNOLOGY AND INNOVATION MORE CENTRIFUGAL FAN CONFIGURATIONS HEATING COOLING GREEN ENERGY EOLO B RT: NEW The new condensing and

More information

GAS FIRED AIR CURTAIN AB 175, AB 225

GAS FIRED AIR CURTAIN AB 175, AB 225 Instruction Manual. GAS FIRED AIR CURTAIN AB 175, AB 225 INDEX Section General Information ----------------------------------------------------------- 1 Dimensions -----------------------------------------------------------------------

More information

"NP" & "RG" AIRFLO. In-duct firing line burner

NP & RG AIRFLO. In-duct firing line burner "NP" & "RG" AIRFLO In-duct firing line burner Duct burners - NP & RG AIRFLO 4-21.5-1 For direct fired fresh air heating applications Operates economically (100 % thermal efficiency) and installs easily

More information

Infiniti Tankless Water Heater Series Featuring SRT (Scale Reduction Technology) The Infiniti Tankless Exclusive Technologies and Features

Infiniti Tankless Water Heater Series Featuring SRT (Scale Reduction Technology) The Infiniti Tankless Exclusive Technologies and Features The Infiniti Tankless Exclusive Technologies and Features Standard Features SRT Scale Reduction Technology Significantly reduces the scale build-up known to result in poor performance, additional maintenance,

More information

NOTICE: The information contained on the following page(s) was produced prior to May 1, On that date Reznor became part of Nortek, Inc.

NOTICE: The information contained on the following page(s) was produced prior to May 1, On that date Reznor became part of Nortek, Inc. NOTICE: The information contained on the following page(s) was produced prior to May 1, 2014. On that date Reznor became part of Nortek, Inc. References to any other company affiliations are no longer

More information

UDSA-4. Gas fired Balanced flue / Fan assisted flue unit heater INSTALLATION COMMISSIONING SERVICING

UDSA-4. Gas fired Balanced flue / Fan assisted flue unit heater INSTALLATION COMMISSIONING SERVICING 1607UDSA-4GBEN UDSA-4 Gas fired Balanced flue / Fan assisted flue unit heater INSTALLATION COMMISSIONING SERVICING These appliances meet the following EC Directives: DIR 2009/142/EC:GAD DIR 2004/108/EC:EMC

More information

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission The New Remeha Quinta Pro Range Condensing Boilers REMEHA QUINTA PRO RANGE HIGH EFFICIENCY 110% NCV AT 40/30 C FULLY MODULATING BOILER CONTROL PREMIX BURNER CLEAN COMBUSTION ULTRA LOW NOx BREEAM EXCELLENT

More information

Technical and Dimensional Data. Saf-T Vent SC Plus

Technical and Dimensional Data. Saf-T Vent SC Plus Technical and Dimensional Data Saf-T Vent S Plus 3"/5" & 4"/7" oncentric Reduced learance Double Wall for Special Gas Vent and/or Sealed ombustion Systems lso For Venting Listed Gas or Oil Fired ppliances

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

The New Remeha Quinta Pro Selection, Design and Installation of Flue Systems

The New Remeha Quinta Pro Selection, Design and Installation of Flue Systems The New Remeha Quinta Pro Selection, Design and Installation of Flue Systems HIGH EFFICIENCY 110% NCV AT 40/30 C FULLY MODULATING BOILER CONTROL PREMIX BURNER CLEAN COMBUSTION ULTRA LOW NOx BREEAM EXCELLENT

More information

PURIFICATION SOLUTIONS. R-Series 1. cycling refrigeration compressed air dryers flow capacity: scfm ( Nm 3 /hr)

PURIFICATION SOLUTIONS. R-Series 1. cycling refrigeration compressed air dryers flow capacity: scfm ( Nm 3 /hr) PURIFITION SOLUTIONS R-Series R cycling refrigeration compressed air dryers flow capacity: 20-2000 scfm (34-3400 Nm 3 /hr) R-Series cycling refrigeration compressed air dryers flow capacity: 20-2000 scfm

More information

THE CARRIER COMFORT LINE

THE CARRIER COMFORT LINE SPLIT SYSTEM SPLIT SYSTEM AIR/AIR TECH 2000 38 TUA/38 CKX 38 YCX - FB4 ASX THE CARRIER COMFORT LINE OUTDOOR UNIT THE ROAD TO All the materials used are designed and protected to resist the toughest climates:

More information

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY: INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS (CHECK ONE) PROPANE GAS PROJECT: ARCHITECT/ENGINEER: NAME: ADDRESS: NAME: ADDRESS: DATE: CONTRACTOR: SUBMITTED BY: NAME: ADDRESS: EQUIPMENT

More information

INSTALLATION AND SERVICE MANUAL

INSTALLATION AND SERVICE MANUAL INSTALLATION AND SERVICE MANUAL VERTICAL COMBUSTION AIR INLET KITS CATEGORY III VENTING FOR SEPARATED COMBUSTION TUBULAR GAS FIRED UNIT HEATERS USE 5 INCH KIT FOR UNITS WITH CAPACITIES 100,000 TO 250,000

More information

Direct-fired make-up air units from Modine include the following:

Direct-fired make-up air units from Modine include the following: M/M, MM, & MR/MR MK-UP IR UNITS IRT-IR MK-UP IR Modine has developed the best in direct-fired make-up air units, the M Series. irect-fired make-up air units are designed to provide an economical and efficient

More information

Design Specifications for Panda 900A Car Spray Booth

Design Specifications for Panda 900A Car Spray Booth Design Specifications for Panda 900A Car Spray Booth Panda Spray Booths are designed and manufactured to suit the various industrial requirements such as, trucking, marine, agriculture, construction machinery,

More information

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER 5 MODELS: 399,000 800,000 BTU/HR FIRING RATE MODULATION TO 5:1 LESS THAN 30 ppm NOx DIRECT-VENT

More information

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 is the new wall-hung condensing boiler for room heating only, set-up for independent functioning and for that in cascade mode

More information

MODEL ADF/ADFH 300 and 500 INDOOR/OUTDOOR DIRECT-FIRED GAS HEATING/MAKEUP AIR SYSTEM FOR INDUSTRIAL & COMMERCIAL APPLICATIONS

MODEL ADF/ADFH 300 and 500 INDOOR/OUTDOOR DIRECT-FIRED GAS HEATING/MAKEUP AIR SYSTEM FOR INDUSTRIAL & COMMERCIAL APPLICATIONS MODEL ADF/ADFH 300 and 500 FOR INDUSTRIAL & COMMERCIAL APPLICATIONS Model ADF CSA 3.7 ANSI Z83.4 Non-Recirculating Industrial Air Heaters WARNING: GAS-FIRED APPLIANCES ARE NOT DESIGNED FOR USE IN HAZARDOUS

More information

GQVC-12 HVAC EQUIPMENT. GAS-FIRED INDOOR HEATING EQUIPMENT A complete line of effi cient heating solutions for large, open spaces.

GQVC-12 HVAC EQUIPMENT. GAS-FIRED INDOOR HEATING EQUIPMENT A complete line of effi cient heating solutions for large, open spaces. GQVC-12 HVAC EQUIPMENT GAS-FIRED INDOOR HEATING EQUIPMENT A complete line of effi cient heating solutions for large, open spaces. 80% thermal efficiency. Heat Exchangers have a tough job to do. It's no

More information

Lanemark Midco HMA2A Series Air Heating Burner and DB Duct Burner System Application Manual

Lanemark Midco HMA2A Series Air Heating Burner and DB Duct Burner System Application Manual Lanemark Midco HMA2A Series Air Heating Burner and DB Duct Burner System Application Manual HMA2A Burners DB Duct Burner Systems Contents Section 1 Section 2 Section 3 Section 4 Introduction Design Calculations

More information

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0307 L5 Revised 11 2006 G51MP SERIES UNITS G51MP G51MP series units are high efficiency multiple position (upflow, downflow, horizontal left and horizontal right) gas furnaces

More information

Blarenberglaan 21 B 2800 MECHELEN Tel.: +32 (0) Fax: +32 (0)

Blarenberglaan 21 B 2800 MECHELEN Tel.: +32 (0) Fax: +32 (0) Multicalor MC Air handlers for heating and optional cooling Brand: Base model: Variants: Country of destination: Electrical supply: Maximum supply pressure: Multicalor MC20 MC30 MC40 UK 230V~ AC 50Hz 6

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS VERTICAL COMBUSTION AIR INLET KITS CATEGORY III VENTING FOR SEPARATED COMBUSTION TUBULAR GAS FIRED DUCT FURNACES USE 5" KIT FOR UNITS WITH CAPACITIES 100,000 TO 200,000 BTU/HR

More information

SURE HEAT MANUFACTURING

SURE HEAT MANUFACTURING SURE HEAT MANUFACTURING Installation and Operating Instructions for NATURAL & L.P. GAS A.G.A. SINGLE & DUAL BURNER VENTED UNITS Model: RP (8,24,30)-N GO (8,24,30)-N GLO (8,24,30)-N WO (8,24,30)-N CO (8,24,30)-N

More information

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com Hybrid Series Innovative Heating Solutions continentalheatingandcooling.com HybridSeries WOOD & Combination FUEL Furnaces Continental s Hybrid Multi Fuel Combination Furnaces are extremely clean burning

More information

NVxEA External Gas Unit Heater

NVxEA External Gas Unit Heater NVxEA External Gas Unit Heater Industrial & Commercial Heating Systems www.powrmatic.co.uk +44 (0) 1460 53535 info@powrmatic.co.uk ErP READY 2018 POWRMATIC PRODUCT INDUSTRIAL & COMMERCIAL & COMMERCIAL

More information

! WARNING: FIRE OR EXPLOSION HAZARD. Applies to: Model SC, Separated-Combustion Duct Furnace. Model SC INSTALLATION / OPERATION / MAINTENANCE

! WARNING: FIRE OR EXPLOSION HAZARD. Applies to: Model SC, Separated-Combustion Duct Furnace. Model SC INSTALLATION / OPERATION / MAINTENANCE Form I-SC (05-15) Obsoletes Form I-SC (12-14) INSTALLATION / OPERATION / MAINTENANCE Applies to: Model SC, Separated-Combustion Duct Furnace Model SC CUSTOMER CQS AGENCY CONVERGENT QUALITY SYSTEM PRODUCT

More information

Hazardous Area Portable Fan Heater The Bulldog

Hazardous Area Portable Fan Heater The Bulldog Hazardous Area Portable Fan Heater The Bulldog www.exheat-industrial.com MFH The Bulldog Portable Fan Heater EXHEAT Industrial s MFH The Bulldog Portable Fan Heater is the world s first truly portable

More information

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com Hybrid Series Innovative Heating Solutions continentalheatingandcooling.com Hybrid 100 For heating requirements up to 1400 sq. ft. the Hybrid100 is up to the task. It can be connected to a new or existing

More information

AXIAL HEATER TROUBLE SHOOTING GUIDE. Models: AX24 N/PV, AX24 N/PV LT, AX24 LP AX26 N/PV, AX26 N/PV LT, AX26 LP AX28 N/PV, AX28 N/PV NT, AX28 LP

AXIAL HEATER TROUBLE SHOOTING GUIDE. Models: AX24 N/PV, AX24 N/PV LT, AX24 LP AX26 N/PV, AX26 N/PV LT, AX26 LP AX28 N/PV, AX28 N/PV NT, AX28 LP AXIAL HEATER TROUBLE SHOOTING GUIDE Page 1 July 2009 Table of Contents Frequently Asked Questions... 3 Axial Heater CONTROL (Siemens LME69) Troubleshooting Chart... 4 Axial Heater BURNER Troubleshooting

More information

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing Mascot Gas-Fired Residential and Commercial Wall-Mounted Boiler Easy Installation, 96% Efficiency, Fully Condensing Mascot is a high-efficiency, wall-mounted boiler available in three BTU sizes 126, 167,

More information

Gas-Fired Indoor and Outdoor Duct Furnaces

Gas-Fired Indoor and Outdoor Duct Furnaces October, 2010 Gas-Fired Indoor and Outdoor Duct Furnaces INDOOR GRAVITY AND POWER VENTED DFG/DFP, DBG/DBP, DCG/DCP INDOOR SEPARATED COMBUSTION DFS, DBS, DCS OUTDOOR GRAVITY AND POWER EXHAUSTED H Series

More information

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 95%+ AFUE Input 45,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

96.7 THE NEW GENERATION OF OIL-FIRED WARM AIR FURNACES + COMFORTABLE + PERFORMANCE + ECONOMICAL OPERATION + EASE OF MAINTENANCE + VERSATILE AFUE UP TO

96.7 THE NEW GENERATION OF OIL-FIRED WARM AIR FURNACES + COMFORTABLE + PERFORMANCE + ECONOMICAL OPERATION + EASE OF MAINTENANCE + VERSATILE AFUE UP TO THE NEW GENERATION OF OIL-FIRED WARM AIR FURNACES 4-WAY MULTIPOISE (KHM) CHE 9%+ LOWBOY REAR BREECH (KLC) LOWBOY FRONT BREECH (KLF) + PERFORMANCE ENERGY STAR CERTIFIED AT ALL FIRING RATES * + ECONOMICAL

More information

BENSON OIL UNIT HEATER 2 RANGE

BENSON OIL UNIT HEATER 2 RANGE BENSON OIL UNIT HEATER 2 RANGE I N S T A L L A T I O N C O M M I S S I O N I N G S E R V I C I N G U S E R I N S T R U C T I O N S Issue 2 January 2006 PART NO 33-65-190 1 Section Contents Page No 1.0

More information

Installation and user manual

Installation and user manual Installation and user manual Strebel SC30K Combi-unit (central heating + domestic hot water) Strebel SC30B Central heating unit (suited for external boiler) Strebel SC30C Central heating unit Wall hung,

More information

Operating instructions

Operating instructions 6304 0307 04/2005 US For the installer Operating instructions Sealed combustion boiler Logano GA24 SC and atmospheric boiler Logano G24X II/SP If these instructions are not followed exactly, a fire or

More information

Oil Heating. Low Profile Highboy Furnaces OH6, OD6, OH8 Series. Built Tough for Lifetime Comfort

Oil Heating. Low Profile Highboy Furnaces OH6, OD6, OH8 Series. Built Tough for Lifetime Comfort Oil Heating Low Profile Highboy Furnaces OH6, OD6, OH8 Series Built Tough for Lifetime Comfort Oil Heating At Its Best Thermo Pride Dependable Craftsmanship For over 60 years, we at Thermo Pride have listened

More information

GME8. Two-Stage Convertible, Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

GME8. Two-Stage Convertible, Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h Two-Stage onvertible, Multi-Speed EM Gas Furnace 80% AFUE Heating Input: 60,000 100,000 BTU/h ontents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow Data... 5 Wiring Diagrams...

More information

SUPER SAVER XL TM HEATER

SUPER SAVER XL TM HEATER Owner s Manual SUPER SAVER XL TM HEATER Agricultural Building Heater Model SS-225-XL 65.9 kw 225,000 BTUH Hot Surface Ignition Wash Down Design FOR YOUR SAFETY If You Smell Gas: 1. Open windows 2. Do not

More information

DELTA-TE III. Nozzle-mix line burner

DELTA-TE III. Nozzle-mix line burner 4-21.7-1 DELTA-TE III Nozzle-mix line burner Combines excellent flexibility with extreme low emissions for direct firing Especially designed for firing in low oxygen, high humidity and/or inert process

More information