BENSON.... Variante3 Fired Unit Heaters...

Size: px
Start display at page:

Download "BENSON.... Variante3 Fired Unit Heaters..."

Transcription

1 NSON Variante3 as ired Unit Heaters

2 3 Variante... as ired Unit Heaters... The new Variante3 builds on the technical excellence of the previous range to provide cost effective and robust heating for industrial and commercial buildings. Using wall or roof mountings, the heaters are available for either room sealed or conventional power flue applications. Model Range There are 2 Variante ranges: >> VR axial fan >> VR centrifugal The Variante gas fired units are available with eleven heat outputs for use on natural gas (20) as standard, but alternatively can be specified for use on propane (31). VR heaters are fitted with axial fans and discharge warm air through a front outlet fitted with both horizontal and vertical louvers. Units can be turned through 900 and blow vertically downwards when using the rear mounted suspension points. Specification abinet ormed from electro-zinc plated sheet steel and painted epoxy pebble grey (RL 7032) to give a robust and durable finish. Louvres urner In-shot burner type with automatic spark ignition and full safety flame proving. On/ Off control is supplied as standard with painted yellow olive (RL 6014) (VR Only) High/Low and modulating control optional. Heat xchanger Tubular four-pass serpentine arrangement manufactured as standard from alumised steel with stainless steel option. Power Venter lue an Variante3 are fitted with a powerful venter fan that enables exhaust & combustion air to be run up to a maximum of 9m each. VR heaters are fitted with direct drive centrifugal fans and discharge warm air via a duct spigot on the outlet (optional louvers are available for free-blowing applications). or applications requiring a ducted connection on the inlet, an optional blower cabinet is available which can also be fitted with filters with filters and/or mixing dampers if required.

3 NSON as fired unit heaters... Options > > Top flue outlet (VR) > > Stainless steel heat exchanger > > High/low or modulating burner > > 30deg or 60deg downflow heads > > Wall brackets (VR) > > estratification thermostat > > lower cabinet > > ilters* > > Mixing dampers with either two position or modulating damper motor* VR VR complete with duct spigot outlet VR complete with optional blower cabinet lectric Motors ll electric motors are rp compliant where necessary. fficiency ach heater within the Variante range has been designed and developed with fuel efficiency in mind with efficiencies exceeding the mandatory requirements of building regulations. uel Heaters are supplied for use with natural gas (20) as standard, however propane (31) is available upon request. Sealed ombustion ircuit Variante heaters are factory fitted with a power flue venter that enables the heater to be operated in either room sealed or fan assisted flue mode. The flue fan is safety interlocked with the burner control system via a pressure differential sensor. single phase electrical supply is required to each unit except the VR60 which is three phase. This supply should not be switched off except for maintenance

4 NSON as fired unit heaters... Versatile lue Installation The balanced flue terminal provides both the combustion air inlet and flue outlet from a single building penetration. The terminals are ordered separately from the heaters to suit either a wall outlet or roof outlet. dditional flue and combustion air pipes may be added, up to a maximum of nine metres of flue pipe, plus nine metres of combustion air pipe. (This reduces by 1.5 metres for every 90 bend fitted). Installation Units may be suspended or alternatively mounted on a suitable non-combustible support. Integral suspension points complete with an M10 female thread are provided to each heater. alanced flue wall outlet (type 12) eliminates expensive roof opening and flashing alanced flue roof outlet (type 32) single phase electrical supply is required to each unit except the VR60 which is three phase. This supply should not be switched off except for maintenance. Min 300 mm Units must not be installed in atmospheres containing flammable or explosive vapours, combustible dust, halogenated hydrocarbons or chlorinated vapours. They are also unsuitable for areas where contaminants may affect electrical motors or connections. ombustion air through wall, flue outlet through the roof (52) Separate combustion air and flue pipes (type 12) for applications where wall thickness exceeds maximum length shown in flue dimension table Heater positions and flue arrangements illustrate VR models and are indicative only. or heater and flue clearances please refer to the appliance installation and maintenance instructions. To complement the Variante units a versatile range of Smartom control panels are available Optimised ontrol > > Self adapting optimum start and stop > > asy set overtime and holiday periods Remote burner reset facility > > Password protection to prevent unauthorised adjustment > > Simple user friendly programming > > Individual seven day programming > > ay, night and frost (5 ) temperature settings > > Three on/off periods per day > > Hours run and service data logging > > attery back up in the event of mains failure > > High / low or modulating burner control (Smartom MZ required) Optional Smartom MZ panel allows up to 16 panels to be linked for centralised control

5 NSON as fired unit heaters VR VR Technical ata Nominal heat output irflow Temperature rise kw m 3 /h K m 3 /h kg/h lue Outlet 2.22 Model Throw m as onsumption Natural gas 20 Propane N lectrical Supply V/ph/hz 230/240V 1N ~ 50Hz Mounting height(s) m Noise level (1) d() Net weight kg as consumption & outputs based upon natural gas 20 having a calorific value of 10.5kWh/ m3 V & Propane kWh/kg V Minimum gas inlet pressure is 17.5mbar for natural gas & 37mbar for Propane. Maximum inlet pressure is 50mbar. as onnection 1. lectrical onnections. 2. Service Panel. 3. Suspension Points (M10 emale). Tolerance ll imensions ± 2 mm. lue Outlet VR imensions as onnection Model Ref Unit Width Unit Height Unit epth lectrical onnections. Overall epth 2. Service Panel Suspension Points 3. Suspension Points (M10 emale). M10 emale Suspension entres Tolerance ll imensions ± 2 mm lue Outlet & dia as connection Rc 1/2" 1/2" 1/2" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" learances (minimum) Top Rear of an ottom Non ccess Side ccess Side

6 NSON as fired unit heaters VR VR Technical ata Nominal Heat Output min static max static Min static pressure Max static pressure as onsumption Natural as 20 Propane 31 lectrical Supply kw Pa Pa kg/h V/ph/Hz Model /240V 1N ~ 50Hz /415V 3P ~ 50Hz /240V 1N ~ 50Hz lower lectrical Rating W Total lectrical Rating W Noise level d() Net Weight kg Min & max static pressure refers to external static pressure of ductwork (by others) as consumption & outputs based upon natural gas 20 having a calorific value of 10.5kWh/m3 V & Propane kWh/kg V H Minimum gas inlet pressure is 17.5mbar for natural gas & 37mbar for Propane. Maximum inlet pressure is 50mbar. lue Outlet as onnection VR imensions Model Unit Width Unit Height Unit epth Overall epth Suspension Points Suspension entres M10 emale lue Outlet & dia lectrical 130 onnections as onnection Rc 1/2" 1/2" 2. Service 3/4" Panel 3/4" 3/4" 3/4" 3. Suspension Points (M10 emale) uct Outlet Spigot H (O): 533 Outher imensions learances (minimum) Top Rear of an ottom Non ccess Side ccess Side Tolerance ll imensions ± 2 mm

7 NSON as fired unit heaters VR with abinet VR with abinet Technical ata Nominal Heat Output min static max static kw Model Max static pressure Pa as onsumption Natural as 20 Propane 31 lectrical Supply kg/h V/ph/Hz /240V 1N ~ 50Hz /415V 3P ~ 50Hz /240V 1N ~ 50Hz lower lectrical Rating W Total lectrical Rating W Noise level d() Net Weight kg Min & max static pressure refers to external static pressure of ductwork (by others) irflows & max static pressure quoted, exclude the use of optional filters and/or mixing dampers as consumption & outputs based upon natural gas 20 having a calorific value of 10.5kWh/ m3 V & Propane kWh/kg V Minimum gas inlet pressure is 17.5mbar for natural gas & 37mbar for Propane. Maximum inlet pressure is 50mbar. as onnection as onnection lue Outlet SIZ H I 123 J as onnection Suspension VR Points with (M10 abinet emale) imensions lectrical onnections 3. as onnection Model lue Outlet (od) Outher imensions Tolerance ll imensions ± 2 mm Unit Width Suspension Points (M10 emale) 2. lectrical onnections Unit Height as onnection abinet epth (od) Outher imensions Tolerance ll imensions Overall epth ± 2 mm Suspension Points Suspension entres M10 emale lue Outlet & dia learances (minimum) Top Rear of an ottom Non ccess Side ccess Side H H SIZ H I J as onnection Rc 1/2" 1/2" 3/4" 3/4" lue Outlet 3/4" 3/4" uct Outlet Spigot H Suspension Points 502 (M10 emale) lectrical onnections 3. as onnection (od) Outher imensions Tolerance ll imensions ± 2 mm H SIZ

8 NORTK LOL HV (UK) LT ens Pool venue rierley Hill West Midlands Y5 1Q United Kingdom /N/VR/007/0416 Tel: ax: Registered in ngland No Registered office: 10 Norwich Street, London, 4 1. Nortek lobal HV is a registered trademark of Nortek lobal HV Limited. ecause of continuous product innovation, Nortek lobal HV reserves the right to change product specification without due notice.

... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant

... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant ... Variante -4 as ired Unit eaters... rp 2018 rp Lot 21 Seasonal fficiency compliant Variante 4... as ired Unit eaters... The new Variante 4 builds on the technical excellence of the previous range to

More information

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ... LCSA - LCSBD - LCSC Gas Fired Unit Heaters LCSA complete with horizontal and optional vertical louvres LCSA - LCSBD - LCSC... Gas Fired Unit Heaters... The new LCSA builds on the technical excellence of

More information

BENSON AMBIRAD. ... Variante Gas Fired Unit Heaters ... HEATI NG AND VENTILATION S OLUTIONS

BENSON AMBIRAD. ... Variante Gas Fired Unit Heaters ... HEATI NG AND VENTILATION S OLUTIONS NSON Variante as ired Unit Heaters MIR HTI N N VNTILTION S OLUTIONS VR horizontal discharge unit Variante... as ired Unit Heaters... The copact highly efficient Variante heaters provide cost effective

More information

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant ... RHeco... ErP 2021 ErP Lot 21 Seasonal Efficiency and NOx compliant RHeco...... Reznor continue their tradition of manufacturing high efficiency warm air heating equipment with the introduction of the

More information

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant ... RHeco... ErP 2021 ErP Lot 21 Seasonal Efficiency and NOx compliant RHeco...... Reznor continue their tradition of manufacturing high efficiency warm air heating equipment with the introduction of the

More information

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS CI/SfB 56.83 X RHeco Series CONDENSING GAS FIRED UNIT HEATERS RHeco Series CONDENSING GAS FIRED UNIT HEATERS Introduction Features & Benefits Model Range Reznor continue their tradition of manufacturing

More information

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units ... PREEVA EC Gas Fired Heating, Ventilation & Cooling Units... ErP 2018 ErP Lot 21 Seasonal Efficiency and Nx compliant ErP 2018 ErP Lot 21 Seasonal Efficiency and Nx compliant PREEVA EC... Gas Fired

More information

OUH Suspended Oil Unit Heater

OUH Suspended Oil Unit Heater OUH Suspended Oil Unit Heater Industrial & ommercial Heating Systems. www.powrmatic.co.uk HATIN // VNTILATION // AIR ONDITIONIN // O PRODUTS OUH Overview odels Available OUH - reeblowing Oil Unit Heater

More information

OUH Oil Unit Heater Range Controlling your working environment. heating ventilation integrity

OUH Oil Unit Heater Range Controlling your working environment. heating ventilation integrity OUH Oil Unit Heater Range ontrolling your working environment heating ventilation integrity 1 Product Overview Benefits Installer riendly ompact Stainless steel combustion chamber/heat exchanger as standard

More information

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS BENSN... EnviroAir Gas Fired Heating, Ventilation & Cooling Units... AMBIRAD HEATI NG AND VENTILATIN S LUTINS EnviroAir... Gas Fired Heating, Ventilation & Cooling Units... The Benson EnviroAir is a new

More information

Heat Exchanger models

Heat Exchanger models Variante Sarto 3 Heat xchanger odels VR xial an or Models entrifugal an VR ownflow VR i-irectional Variante Introduction The copact highly efficient enson Variante heaters provide cost effective heating

More information

OUH Suspended Oil Unit Heater Gas Oil Fired & Optional Kerosene

OUH Suspended Oil Unit Heater Gas Oil Fired & Optional Kerosene Indirect oil fired heating solution with advanced high/low burners combining form, function and rp compliance. The Powrmatic OUH. OUH Suspended Oil Unit Heater Gas Oil ired & Optional Kerosene OUH Suspended

More information

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS CI/SfB 56.83 X EnviroPak Series GAS FIRED HEATING, VENTIATIN AND CING UNITS EnviroPak Series GAS FIRED HEATING, VENTIATIN AND CING UNITS Introduction The Reznor EnviroPak is a new generation of gas fired

More information

VPC Gas Cabinet Heater Range

VPC Gas Cabinet Heater Range VPC Gas Cabinet Heater Range Industrial & Commercial Heating Systems. www.powrmatic.co.uk HEATING // VENTIATION // AIR CONDITIONING // OEM PRODUCTS VPC Overview Models Available VPC UF - Upright Freeblowing

More information

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning VPC Gas Cabinet Heater Range Architects of your environment heating ventilation air conditioning 1 Product Overview Benefits Installer Friendly ow evel Flue Discharge Option (No Roof Work) Room Sealed

More information

PREEVA air handling unit

PREEVA air handling unit APPICATINS Heating, ventilation, cooling, heat recovery >> FACTRIES >> commercial premises >> WAREHUSES >> HAS >> SPRTS & EISURE >> PACES F WRSHIP >> RESTAURANTS PREEVA air handling unit www.reznor.eu

More information

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted All Heaters Part L2B Compliant Technical Data External Oil and Gas Cabinet Heaters For Models EVD Vertical Ducted EHD Hortizontal Ducted Range & Configuration Vertical Forced Draught Oil and Gas 29 kw

More information

... UDSA - UDSBD Gas fired unit heaters...

... UDSA - UDSBD Gas fired unit heaters... UDSA - UDSBD Gas fired unit heaters UDSA with axial fan Reznor V3 unit heaters are one of the most technically advanced products available on the market today. Incorporating a radical new horizontal heat

More information

VPx. Power Vented Gas Cabinet Heater Nautral Gas & LPG Fired Options

VPx. Power Vented Gas Cabinet Heater Nautral Gas & LPG Fired Options Our most compact power vented gas fired cabinet heater combining form, function and rp compliance. The all new VPx. VPx Power Vented Gas abinet Heater autral Gas & PG ired Options VPx Power Vented Gas

More information

CP+ Gas & Oil Cabinet Heater Range

CP+ Gas & Oil Cabinet Heater Range CP+ Gas & Oil Cabinet Heater Range Industrial & Commercial Heating Systems. www.powrmatic.co.uk CP+ CP+EA External Heater HEATING // VENTILATION // AIR CONDITIONING // OEM PRODUCTS CP+ Overview Designed

More information

Heat Exchanger models

Heat Exchanger models Variante Sarto 3 Heat xchanger odels VR xial an or Models entrifugal an VR ownflow VR i-irectional Variante Introduction The copact highly effi cient enson Variante heaters provide cost effective heating

More information

Gas-fired unit heaters for indoor installation

Gas-fired unit heaters for indoor installation UDSA & UDSBD model Gas-fired unit heaters for indoor installation Reznor V3 unit heaters are one of the most technically advanced products available on the market today. Incorporating a radical new heat

More information

Brute Elite Hydronic Boilers Indoor 285, ,000 BTU/Hr. 95+% Thermal Efficiency

Brute Elite Hydronic Boilers Indoor 285, ,000 BTU/Hr. 95+% Thermal Efficiency rute lite Hydronic oilers Indoor 285,000-850,000 TU/Hr. 95+% Thermal fficiency The unit will be designed and constructed in accordance with the SM oiler and Pressure Vessel ode Section IV requirements

More information

940ESO Tankless Water Heater

940ESO Tankless Water Heater ngineering Submittal Sheet Overview and ertifications LOW-L U P US Massachusetts Plumbing oard pproved ngineering Specifications Water heater shall be a Model Therm 940 SO for outdoor installation. Plant

More information

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw Superior A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler Outputs 120, 160, 200, 240, 280 kw 1 The Superior is a, pre-assembled floor standing, gas fired high efficiency

More information

AMBIRAD.... Vision Radiant Tube Heating Systems...

AMBIRAD.... Vision Radiant Tube Heating Systems... AMBIRAD Vision Radiant Tube Heating Systems * Vision... Radiant Tube Heating Systems... Renowned for its pioneering track record, AmbiRad, Europes leading supplier of radiant tube heating systems, has

More information

RHC GAS FIRED HEATING COILS

RHC GAS FIRED HEATING COILS CI/SfB 56.83 X RHC GS FIRED HETING COILS RHC GS FIRED REZNOR HETING COILS Introduction Reznor gas fired heating coils are designed for inclusion in air handling units to provide a high efficiency gas fired

More information

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

FEATURES AND BENEFITS. Up to 109.8% part load efficiency IMAX XTRA EL. 320kW FLOOR STANDING CONDENSING The Imax Xtra EL range of condensing boilers is available in 5 models with outputs from 320 to 620kW. Suitable for floor standing applications in either single

More information

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS THE UK'S ONLY NOx CLASS 6 RATED FLOOR STANDING BOILER IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING The Imax Xtra EL range of dual condensing boilers is available in 5 models with outputs from 715 to 1240kW.

More information

Brute Elite Volume Water Heaters Indoor 150, ,000 BTU/Hr. Up to 97% Thermal Efficiency

Brute Elite Volume Water Heaters Indoor 150, ,000 BTU/Hr. Up to 97% Thermal Efficiency rute lite Volume ater eaters Indoor 1,000 -,000 TU/r. Up to % Thermal fficiency The unit will be designed and constructed in accordance with the S oiler and Pressure Vessel ode Section IV requirements

More information

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23 Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B Type B 23 on the wall Ø 80 duct, available in the following lengths: 1000,

More information

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas HVAC Guideline Specifications WHISPER-JET: SET SERIES Two Stage Positive Pressure Gas-Fired Infrared Radiant Tube Type Heater Commercial/Industrial Applications Technical Summary Input Range: 80,000/60,000

More information

... Vision Radiant Tube Heating Systems ... ErP. ErP Lot 20 Seasonal Efficiency and NOx compliant

... Vision Radiant Tube Heating Systems ... ErP. ErP Lot 20 Seasonal Efficiency and NOx compliant Vision Radiant Tube Heating Systems ErP 2018 ErP Lot 20 Seasonal Efficiency and NOx compliant * Vision... Radiant Tube Heating Systems... The range of high efficiency Vision radiant tube heaters delivers

More information

G34M Bulletin #69/ August 2003

G34M Bulletin #69/ August 2003 ENGINEERING DATA G34M MULTI POSITION GAS FURNACE 12.4 to 31.0 kw Output 52.7 to 131.9 Mj Input 3.5 to 17.6 kw Nominal Add-on Cooling GAS FURNACES 50 Hz G34M Bulletin #69/490045 August 2003 Typical Applications

More information

Cabinet Heaters. Over 91.5% NET Efficient! Quality in Any Language TM. Ideal for industrial and commercial applications

Cabinet Heaters. Over 91.5% NET Efficient! Quality in Any Language TM. Ideal for industrial and commercial applications Ideal for industrial and commercial applications arge range of heat outputs and burner options Easy installation with a factory fitted bolt-on burner Durable long life stainless steel combustion chamber

More information

FMH Range Hoods. Installation, Operation & Maintenance Instructions

FMH Range Hoods. Installation, Operation & Maintenance Instructions Installation, Operation & Maintenance Instructions Fourneaux de France Ltd Unit 3 Albion Close, Newtown Business Park, Poole Dorset, BH12 3LL Tel 01202-733011 Email info@fdef.co.uk www.fdef.co.uk W1103

More information

TE Powrmaster Heater Range Controlling your working environment. heating ventilation integrity

TE Powrmaster Heater Range Controlling your working environment. heating ventilation integrity TE Powrmaster Heater Range Controlling your working environment heating ventilation integrity Air Rotation Technology Air rotation systems may well be chosen in preference to either radiant heating or

More information

Knight & Charger Water Heaters

Knight & Charger Water Heaters Knight & harger Water eaters rom 127-1853 l/h recovery rate Storage capacities from 109-357 litres ast recovery water heater 3 Year Storage Vessel warranty onventional flued appliance as fired storage

More information

Technology and design with Comfort and Energy Saving in mind. Instantaneous Gas Water Heater Series

Technology and design with Comfort and Energy Saving in mind. Instantaneous Gas Water Heater Series Technology and design with omfort and Energy Saving in mind Instantaneous Gas Water Heater Series Pucada Tech is located in Taiwan with sufficient experiences and capabilities on designing/producing key

More information

Gas-Fired Indoor and Outdoor Duct Furnaces

Gas-Fired Indoor and Outdoor Duct Furnaces July, 2008 Gas-Fired Indoor and Outdoor Duct Furnaces INDOOR GRAVITY VENTED DFG, DBG, DCG INDOOR SEPARATED COMBUSTION DFS, DBS, DCS OUTDOOR GRAVITY AND POWER EXHAUSTED H Series table of contents A complete

More information

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters Sizes 30-125 carry an additional approval for use in residential garage/workshops under CSA International Requirement 10.96 - U.S.

More information

LARGE CAPACITY HEATERS

LARGE CAPACITY HEATERS 250 1,000 Capacities 7.5-12,850 150,000 CFM 200 MBH 250-7,500 MBH - - Tons APPLICATIONS Heating/Cooling/Makeup Air WAREHOUSES / FACTORIES SCHOOLS / UNIVERSITIES COMMERCIAL / RETAIL INDUSTRIAL GYMNASIUMS

More information

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance Installation Operation Commissioning Maintenance HOT AIR GENERATOR WITH GAS BURNER GGS NA11.45 A 06-2011 04-2011 CONTENTS 1. DESCRIPTION OF THE UNIT 2. INSTALLATION & CONNECTION 3. COMMISSIONING 4. CARE

More information

Winterwarm Agri UK. Winterwarm. Winterwarm heating solutions ... Winterwarm-quality. heating solutions

Winterwarm Agri UK. Winterwarm. Winterwarm heating solutions ... Winterwarm-quality. heating solutions Winterwarm Agri UK Winterwarm heating solutions Looking for an efficient heater for your glass house or your poultry house? Winterwarm offers various heating solutions for this purpose.........................................................................

More information

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model Calder Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing Outputs 70-3500 kw Calder Model 70-1300 Calder Model 1400-3500 Calder - Steel Hot Water Boiler The Calder

More information

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment! OnePlus Packaged Air Handling Units for Ducted Installations Caring for the environment! A New Concept New packaged air handling units OnePlus series are the latest offspring of Apen Group s experience.

More information

RHC & RHCE gas fired heating coils

RHC & RHCE gas fired heating coils APPLICATIONS Heating in duct networks or air handling units >> FACTORIES >> WAREHOUSES >> HALLS RHC & RHCE gas fired heating coils www.reznor.eu RHC gas fired heating coils Reznor gas fired heating coils

More information

Sirius FS. Working towards a cleaner future

Sirius FS. Working towards a cleaner future Sirius FS Floor Standing Stainless Steel Condensing Boilers Single Boiler Applications: 50 to 160kW Modular Boiler Applications: up to 640kW Working towards a cleaner future heating specialists 1. Product

More information

BENSON VARIANTE 2 RANGE

BENSON VARIANTE 2 RANGE BENSON VARIANTE 2 RANGE NATURAL GAS (G20 I 2H ) PROPANE GAS (G31 I 3P ) TUBULAR HEATER I N S T A L L A T I O N C O M M I S S I O N I N G S E R V I C I N G U S E R I N S T R U C T I O N S BENSON Issue 5

More information

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model Calder Plus High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing Outputs 70-3500 kw Calder Plus Model 70-1300 Calder Plus Model 1400-3500 Calder Plus - High Efficiency

More information

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL Heating, Air Conditioning, Ventilation Отопление-Кондиционеры-Вентиляция MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL 1. Usage MTM 8-30 universal oil heater is designed for heating commercial rooms

More information

Installation and Operating Manual Drying Cabinet

Installation and Operating Manual Drying Cabinet Drying Cabinet TS-4175 WW CONTENTS THIS USER MANUAL & DATA PLATE DETAILS Page 2 IMPORTANT SAFETY INSTRUCTIONS Page 3 INSTALLATION INSTRUCTIONS Page 4 OPERATING INSTRUCTIONS Page 8 MAINTENANCE INSTRUCTIONS

More information

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A cod. 6272262A GENERAL DATA Heating Data Heat Output Input (Adjustable) (Adjustable) Format 34i 11.2 34KW 45 145MJ/hr Format 34e 11.2 34KW 45 145MJ/hr General Specifications FORMAT 34i 34e Main burner injectors

More information

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements Exceeds Minimum Requirements Hamworthy Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters 18.9 kw to 20.1 kw, Natural Gas or LPG Continuous outputs 369

More information

EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER AIR HEATING TECHNOLOGY AND INNOVATION AXIAL FANS AND CENTRIFUGAL FANS HEATING COOLING GREEN ENERGY EOLO VIP: NEW! VERY IMPORTANT PERFORMANCE The

More information

Elite. Unit Heaters. Installation and Commissioning Manual. Tubular Unit Heaters Elite Range

Elite. Unit Heaters. Installation and Commissioning Manual. Tubular Unit Heaters Elite Range Elite Unit Heaters Installation and Commissioning Manual Tubular Unit Heaters Elite Range 40-115 Unit 20 Red Mill Trading Estate, Rigby Street Wednesbury, West Midlands, WS10 0NP Tel: +44(0)121 5067700

More information

P e l l e t S t o v e S P U R e P e R F o R M A N C e

P e l l e t S t o v e S P U R e P e R F o R M A N C e Pellet Stoves PUR PRORMN Proven Performance Powerful heating performance and easy operation make any Quadra-ire pellet stove a smart investment. Traditional craftsmanship and multiple finishing options

More information

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw The RL/1 burners series covers a firing range from 107 to 398 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Optimisation

More information

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F) UNIT HEATER CATALOG Form RZ-NA-C-UH (Version F) BACKGROUND Reznor was founded in 1888 to manufacture the Reznor reflector heater, which used a luminous flame gas burner developed by George Reznor. This

More information

MODUCEL KW DOWNFLOW COOLING DRU DRU DATA ROOM UNITS

MODUCEL KW DOWNFLOW COOLING DRU DRU DATA ROOM UNITS MOUEL 80-10 KW OWNFLOW OOLING RU RU T ROOM UNITS T ROOM UNITS The Moducel range of high efficiency ata Room Units, are designed for high density load areas where a large cooling duty is required from a

More information

ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER

ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER Yarra s Edge Apartments, Docklands Melbourne RAYPAK Mechanical Heating and Hot Water Green s General Foods, Glendenning. ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER The use of direct fired pure copper

More information

RAYPAK HOT WATER & HEATING

RAYPAK HOT WATER & HEATING All copper & bronze construction On/Off & modulating models High temperature applications RAYPAK HOT WATER & HEATING Raypak is a compact, efficient heating design which is the ideal way to heat large quantities

More information

RAYPAK HOT WATER & HEATING

RAYPAK HOT WATER & HEATING All copper & bronze construction On/Off & modulating models High temperature applications RAYPAK HOT WATER & HEATING Raypak is a compact, efficient heating design which is the ideal way to heat large quantities

More information

Warm Air Cabinet Heaters

Warm Air Cabinet Heaters FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO T try to light any appliance. 3. DO T use electrical switches. 4. DO T use any telephone in your building. 5. Leave the building. 6. Immediately

More information

SGS Condensing High Efficiency Gas-Solar Water Heater

SGS Condensing High Efficiency Gas-Solar Water Heater ondensing High Efficiency as-solar ater Heater - 8/0/0/0/80/100/10 Solar control Storage tank ully room-sealed condensing high efficiency gas-solar water heater Maximum solar contribution through fully

More information

NVx Suspended Gas Unit Heater Range

NVx Suspended Gas Unit Heater Range Issue 5.9 April 2016 NVx Suspended as Unit Heater Range Industrial & Commercial Heating Systems. www. p o w r m a tic. c o.uk Users, Installation and Servicing Instructions (Pactrol Control, MKIII LIB

More information

BENSON LINEAR RADIANT TUBE

BENSON LINEAR RADIANT TUBE BENSON LINEAR RADIANT TUBE Natural or Propane (Gas fired) I N S T A L L A T I O N C O M M I S S I O N I N G S E R V I C I N G U S E R I N S T R U C T I O N S September 2001 CONTENTS Page Compliance Notices

More information

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces SG-UUH-03 November 2014 Specification Guide FSA, FOA, & HED Series Unit Heaters and Duct Furnaces Product improvement is a continuous process at Advanced Distributor Products. Therefore, product specifications

More information

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h Savile Plus Steam Boiler Suitable for Pressure Jet burners Oil, gas or dual fuel firing Outputs 380-5425 kg/h 1 Savile Plus - Steam Boiler The Savile Plus is a range of three pass wet back reverse flame

More information

CI/SfB X. Vision RADIANT TUBE HEATING SYSTEMS

CI/SfB X. Vision RADIANT TUBE HEATING SYSTEMS CI/SfB 56.83 X Vision RADIANT TUBE HEATING SYSTEMS Vision RADIANT TUBE HEATING SYSTEMS Introduction The new range of high efficiency Vision radiant tube heaters delivers exceptional performance in terms

More information

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models July, 2009 Gas-Fired Power Vented Unit Heaters Propeller & Blower Models MODEL HD MODEL HDB MODEL PDP MODEL BDP TABLE OF CONTENTS Modine s power vented unit heaters are designed for the heating requirements

More information

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh PRODUCT SPECIFICATIONS GAS UNIT HEATERS / DUCT FURNACES TU T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ Bulletin No. 20402 November 207 Supersedes November 206

More information

Products and prices. CLIMATE TECHNOLOGY feels better, works better.

Products and prices. CLIMATE TECHNOLOGY feels better, works better. Products and prices CLIMATE TECHNOLOGY feels better, works better. www.markclimate.com Long-term leaders in climate management Get to know the specialist in the Netherlands in the field of air heating,

More information

CTU Unit Heaters. Installation, Commissioning, Operation & Service Manual. Model CTU 22 to 115. Quality in Any Language Copyright 2003 Roberts-Gordon

CTU Unit Heaters. Installation, Commissioning, Operation & Service Manual. Model CTU 22 to 115. Quality in Any Language Copyright 2003 Roberts-Gordon FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Leave the building. 6. Immediately

More information

BENSON VARIANTE 2 RANGE

BENSON VARIANTE 2 RANGE BENSON VARIANTE 2 RANGE GAS FIRED TUBULAR HEATER I N S T A L L A T I O N C O M M I S S I O N I N G S E R V I C I N G U S E R I N S T R U C T I O N S Issue 3 June 2006 PART NO 33-64-695 1 Section Contents

More information

C1210ESC Tankless Water Heater

C1210ESC Tankless Water Heater Engineering Submittal Sheet Overview and ertifications L W LOW-LEAD U P US Massachusetts Plumbing Board Approved Engineering Specifications Water heater shall be a Model Therm 1210 ES. Plant shall consist

More information

WHHR Midi & Midi Lite

WHHR Midi & Midi Lite WHHR Midi & Midi Lite Residential Whole House Heat Recovery Units with Low Energy EC Motors Optional - Integral LCD Installation, Operating and Maintenance Instructions Image of model with LCD screen Page

More information

Application instructions

Application instructions 0603RHC4-JLGBEN Application instructions RHC 4000(M) RJL RHC 4000(M) DJL Jacket-less, Gas fired, Balanced flue, Power vented, Air heater This document applies when installing into an air handler or as

More information

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h Metropolitan Steam Boiler Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing Outputs 1845-21 700 kg/h 1 Metropolitan - Steam Boiler The Metropolitan is a range of high pressure

More information

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of

More information

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW Stainless steel range of condensing boilers Outputs from 50kW to 660kW Designed to meet carbon reduction targets Lifetime service and support Totally dependable. page 1 www.pottertoncommercial.co.uk Contents

More information

Fundamentals of a gas fire New Zealand. August 2017

Fundamentals of a gas fire New Zealand. August 2017 Fundamentals of a gas fire New Zealand August 2017 1 INDEX Fundamentals of a gas fire 3. Ventilation To room space 4. Mechanical ventilation & Smart home connection 5 8. Finish 9 10. Finish face details

More information

GAS UNIT HEATERS ARM RANGE

GAS UNIT HEATERS ARM RANGE GAS UNIT HEATERS ARM RANGE ARM Simple and reliable heater Efficiency up to % Fleaxiheat Gas Unit Heaters - ARM series are suitable for indoor installation in industrial and commercial premises. Thanks

More information

Sirius WH. Working towards a cleaner future

Sirius WH. Working towards a cleaner future Sirius WH Wall Hung Stainless Steel Condensing Boilers Single Boiler Applications: 50 to 110kW Modular Boiler Applications: up to 880kW Working towards a cleaner future heating specialists 1. Product Overview

More information

Users manual. Buderus /29/43/60 and Buderus T25/29T25 H/V. Wall-mounted condensing gas boiler. For the user

Users manual. Buderus /29/43/60 and Buderus T25/29T25 H/V. Wall-mounted condensing gas boiler. For the user Users manual Wall-mounted condensing gas boiler Buderus 800-24/29/43/60 and Buderus 800-24T25/29T25 H/V For the user Please read thoroughly before operating the unit 722 3700 (03/200) GB Preface Introduction

More information

NVx Suspended Gas Unit Heater

NVx Suspended Gas Unit Heater NVx Suspended as Unit Heater Industrial & Commercial Heating Systems www.powrmatic.co.uk +44 (0) 1460 53535 info@powrmatic.co.uk rp RADY 2018 POWRATIC PRODUCT INDUSTRIAL & CORCIAL & CORCIAL WAR HATIN AIR

More information

PSO Gas & Oil Cabinet Heater Range

PSO Gas & Oil Cabinet Heater Range PSO as & Oil abinet eater Range Industrial & ommercial eating Systems rp RDY 2018 POWRTI PRODUT WWW.TROBI.O.UK INDUSTRI & & ORI WR TIN IR TIN SOUTIONS Thermobile PSO The PSO range of heaters from Thermobile

More information

BENSON GAS UNIT HEATERS

BENSON GAS UNIT HEATERS BENSON GAS UNIT HEATERS Types VRA 065/090/110/140/170/220/285 Types VRC 065/090/110/140/170 Types VRE 090/110//170/220 49/AU/2840 0049 VARIANTE RANGE INSTALLATION AND SERVICE MANUAL Issue 2 0ctober 2003

More information

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil UNIT HEATER CATALOG COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS FUEL Natural Gas Propane Fuel Oil CAPACITIES 25-1,200 MBH 80% - 93% Thermal Efficiency 380-16,750 CFM AIR DELIVERY Propeller

More information

MODEL PVF INDIRECT GAS FIRED FURNACES FOR ENERGY RECOVERY UNITS Installation, Operation, and Maintenance Manual

MODEL PVF INDIRECT GAS FIRED FURNACES FOR ENERGY RECOVERY UNITS Installation, Operation, and Maintenance Manual RETIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Part # 461006 MODEL PVF INDIRECT GS FIRED FURNCES FOR ENERGY RECOVERY UNITS Installation, Operation, and Maintenance Manual Model PVF, Indirect Gas Furnace,

More information

SUBMITTAL SCHEDULE & DATA

SUBMITTAL SCHEDULE & DATA SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Job Name: Date: 10/31/2016 Location: Engineer: Submitted by: Jeff Musto Architect: Contractor: Model

More information

STATIONARY HEATERS 2011/

STATIONARY HEATERS 2011/ STATIONARY HEATERS 2011/2012 FoR over 50 years www.mcsgl.com 2 Master Climate Solutions is a world leading manufacturer of machinery for air processing. Our machines are designed for professionals and

More information

INFRARED RADIANT HEATERS

INFRARED RADIANT HEATERS IRH-1R INFRARED RADIANT HEATERS High and Low Intensity RSU SERIES Unit is shown rotated at a 45 angle. RSD SERIES HIGH INTENSITY INFRARED HEATERS RSD Series Ceramic Heaters Special Honeycomb Tile Design

More information

INSTALLATION & SERVICING MANUAL FOR BENSON VARIANTE² TUBULAR HEATER NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

INSTALLATION & SERVICING MANUAL FOR BENSON VARIANTE² TUBULAR HEATER NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P) INSALLAION & SERVICING MANUAL FOR BENSON VARIANE² UBULAR HEAER NAURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P) WARNINGS Benson equipment must be installed and maintained in accordance with the relevant

More information

PT Radiant Heater Range Controlling your working environment. heating ventilation integrity

PT Radiant Heater Range Controlling your working environment. heating ventilation integrity PT Radiant Heater Range Controlling your working environment heating ventilation integrity 1 PTUL and PTSL Radiant Tube Heaters PTUL / PTSL Radiant Tube Heaters Part L 2010 Compliant - High Efficiency

More information

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS 48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,

More information

THE CARRIER COMFORT LINE

THE CARRIER COMFORT LINE SPLIT SYSTEM SPLIT SYSTEM AIR/AIR TECH 2000 38 TUA/38 CKX 38 YCX - FB4 ASX THE CARRIER COMFORT LINE OUTDOOR UNIT THE ROAD TO All the materials used are designed and protected to resist the toughest climates:

More information

OUH Suspended Oil Unit Heater Industrial & Commercial Heating Systems

OUH Suspended Oil Unit Heater Industrial & Commercial Heating Systems OU Suspended Oil Unit eater Industrial & Commercial eating Systems www.powrmatic.co.uk +44 (0) 1460 53535 info@powrmatic.co.uk rp RDY 2018 POWRMTIC PRODUCT INDUSTRIL & COMMRCIL WRM IR TIN SOLUTION INDUSTRIL

More information

LUH HORIZONTAL FAN-FORCED UNIT HEATER

LUH HORIZONTAL FAN-FORCED UNIT HEATER LUH HORIZONTAL FAN-FORCED UNIT HEATER VERSATILE, FAN-FORCED HEATING FOR COMMERCIAL AND INDUSTRIAL COMFORT HEAT APPLICATIONS Horizontal airflow Wall or ceiling mounting Self-contained Totally enclosed fan

More information

GAS AIR HEATER RANGE

GAS AIR HEATER RANGE GAS AIR HEATER RANGE ATH Horizontal gas air heater ATC Centrifugal gas air heater ATV Vertical gas air heater Address : Yahtec - 6 rue Pascal 7700 Meaux - France Phone number :+ (0) 60 4 4 86 Multiple

More information