TWXC F3 Series 50Hz. Water Cooled Horizontal Screw Chiller Flooded Evaporator Cooling Capacity: 97 to 506 TR (340 to 1780 kw)

Size: px
Start display at page:

Download "TWXC F3 Series 50Hz. Water Cooled Horizontal Screw Chiller Flooded Evaporator Cooling Capacity: 97 to 506 TR (340 to 1780 kw)"

Transcription

1 TWXC F3 Series 50Hz Water Cooled Horizontal Screw Chiller Flooded Evaporator Cooling Capacity: 97 to 506 TR (340 to 780 kw)

2 Contents Contents 02 Nomenclature 03 Features and benefits 07 Specifications 0 Dimensions 8 Selection software

3 R34a Flooded (97 to 506 tons) TOPIRE water cooled screw chiller is the mature products which use flooded type evaporator and high efficiency compressor. Optimized system design and enhanced heat exchange efficiency make the unit working best under both full load and partial load. Every chiller is fully factory tested and gas charged in the factory before dispatch. It s good choice for hotel, shopping mall, hospital, factory, cinema and other civil architecture air conditioning system. Besides, it is widely used in plastic industry, electroplating industry, food processing, chemical industry and other technological process which needs plenty of chilled water. TWXC - F3 TOPIRE Water-Cooled Horizontal Screw Chiller Model Code Refrigerant type F3: R34a Structure Electrical control panel Touchscreen panel High efficiency screw compressor Flooded type evaporator Emergency button Safety release valve Shell and tube condenser Electronic expansion valve Fast connection victaulic fitting 2

4 Features and benefits Green chiller R34a Flooded (97 to 506 tons) R34a environmentally-friendly refrigerant: Refrigerant is chlorine-free HFC with zero ODP (Ozone Depletion Potential). Very low GWP (Global Warming Potential). Stable and Reliable dvanced twin-rotor screw compressor djustable capacity valve Four stage adjustable capacity or stepless adjustment. Built-in oil separator High precision filter, oil separation efficiency up to 99.5%. Direct motor drive High mechanical efficiency, low compressor speed, low noise levels. Refrigerant discharge Exhaust cavity with check valve, it helps avoid extended stoppages caused by compressor reversal. Twin screw rotor Patented type line design, high volumetric efficiency, smooth operation. Hermetic motor Refrigerant cooled motor, no expelled heat. Semi- hermetic structure Semi-hermetic compressor, moveable bolts, easy maintenance. High efficiency heat exchange technology Evaporator Condenser Gas refrigerant Chilled water outlet Filter Gas refrigerant inlet Filter Cooling water outlet EXV Liquid refrigerant Tube Chilled water inlet Liquid refrigerant outlet Cooling water inlet Orifice High efficiency shell and tube heat exchanger, 2 pass, straight water pipe, easy to clean. Both two side cover can be exchanged to meet customer s requirement for condenser. 3

5 R34a Flooded (97 to 506 tons) dvanced oil system doption of the special oil separation and return system, built-in oil separator, ensure the systems' stability.the lubrication system can heat oil to match the chillers exact requirements, guaranteeing the system is always protected against unnecessary wear. User-friendly operating interface Complete and safe control system: The unit is designed with multiple security measures to ensure safety and reliability. ll sensors and safety features are assembled, equipped and undergo strict testing in factory. Touchscreen display: Color coded, easy for operation. Three status indicators on the screen clearly indicate power, system status and counication Intelligent control By monitoring all parameters, the intelligent control logic decides the best load adjustment method, it optimizes the EXV and the capacity slider to guarantee safe operation under various load conditions. Conventional BMS systems only focus on the interlock control, operation status and parameter monitoring, which achieves automation and energy management,but fails to realize the benefits of equipment synchronization. Topaire centralized energy management system attaches importance to building load prediction and control, and coordinates the operation of air-conditioner, fan and water pumps to realize optimum energy management. System control functions: Pragmatic control modes Equalized operation time Touchable Screen Central Controller Electricity panel Optimum operation schedule System data report Strategies to address problems Remote counication function Pressure difference sensor Temperature sensor Water flow meter Electrical operated valve Chilling water pump Chilled water pump Cooling tower Centrifugal Chiller Centrifugal Chiller Screw Water Chiller 4

6 Electrical control R34a Flooded (97 to 506 tons) Topaire intelligent controller Topaire water cooled screw chiller adopts a Microprocessor controller which enables the user to monitor and control the chiller with precise accuracy. The Microprocessor control system guarantees high precision and stability. The moduledesigned control system is easy for installation and maintenance. The chiller comes with a reserved RS485 port which can be interfaced with BS (Building utomation system). Remote monitoring and control of the chiller is possible. True color touchscreen Control regulations,operating parameters, diagnostics reports, and error messages are all displayed on a 7 inch, colors TFT screen with resolution. The screen also displays error codes, various settings, specified temperature and pressure values, the status of operating parameters and options. Weekly operation scheduling The user can set the chiller operation schedule on the weekly timetable to run and stop the chiller automatically. If an unscheduled shutdown occurs, the chiller will not restart unless manually reset. Power-down memory function When powered-down, the chiller will maintain previous running mode and parameter set point. 5

7 R34a Flooded (97 to 506 tons) Data acquisition & storing Records a max. of 256 of the lastest alarms and 500 seconds of chilled/cooling water temperature trend display. Password protection user, installation and coissioning technician as well as a factory password are pre-generated for each unit. Unauthorized access to the control is protected by randomly-generated passwords. Self-Diagnosis Self-diagnosis is always performed prior to start-up to enable safe operation. Only after all the requirements are met, the chiller will start. If any malfunction occurs, it will be displayed on the screen. Multiple protection features guarantee the safety and stability of the unit Items High/low pressure protection Power open phase protection nti-freeze protection under cooling mode Frequent startup protection Overcurrent protection of Comp. Overheat protection of compressor Water flow protection Reversal protection control(prs) Function Guarantees the Comp. runs in the right range thus ensuring its lifespan Protects Comp. from damage in case of open phase or anti-phase Protects the evaporators' copper pipes from damage caused by water freeze Protects Comp. motor winding from burnout caused by frequent startup Protects Comp. from burnout caused by heavy current Protects Comp. from damage caused by a lack of refrigerant or lubricant Protects Comp. from burnout caused by heat-exchanger failure Guarantees the comp. motor runs in the right direction 6

8 Specifications TWXC_F Cooling capacity RT Cooling capacity kw R34a Flooded (97 to 506 tons) Power input COP Semi-hermetic screw compressor kw kw/kw Circuit Circuit B Quantity Quantity Oil recharge Circuit L Circuit B L Refrigerant Type R34a Circuit kg Circuit B kg Control Type EXV+Orifice Evaporator Type Shell and Tube Flooded Water flow m 3 /h Pressure drop kpa Max. pressure kpa Connection Type Victaulic coupling Water inlet/outlet pipe dim. DN50 DN50 DN50 DN200 DN200 DN200 Condenser Type Shell and Tube Water flow Pressure drop m 3 /h kpa Max. pressure kpa Connection Type Victaulic coupling Water inlet/outlet pipe dim. DN50 DN50 DN50 DN200 DN200 DN200 Unit length Unit width Unit height Packing length Packing width Packing height Net weight Shipping weight Running weight kg kg kg Note: Nominal cooling capacities are based on following conditions: Chilled water inlet/outlet temperature 2/7 C(53.6 F /44.6 F); Cooling water inlet/outlet temperature 30/35 C(86 F /95 F). The design fouling factor for evaporator is 0.076m 2 C/kW(0.000ft 2 F.hr/Btu) and for condenser is 0.044m 2 C/kW( ft 2 F.hr/Btu). 7

9 R34a Flooded (97 to 506 tons) TWXC_F Cooling capacity RT Cooling capacity kw Power input COP Semi-hermetic screw compressor kw kw/kw Circuit Quantity Circuit B Quantity Oil recharge Circuit L Circuit B L Refrigerant Type R34a Circuit kg Circuit B kg Control Type Evaporator Type EXV+Orifice Shell and Tube Flooded Water flow m 3 /h Pressure drop kpa Max. pressure kpa Connection Type Water inlet/outlet pipe dim. Condenser Type Victaulic coupling DN200 Shell and Tube Water flow m 3 /h Pressure drop kpa Max. pressure kpa Connection Type Water inlet/outlet pipe dim. Victaulic coupling DN200 Unit length Unit width Unit height Packing length Packing width Packing height Net weight kg Shipping weight kg Running weight kg Note: Nominal cooling capacities are based on following conditions: Chilled water inlet/outlet temperature 2/7 C(53.6 F /44.6 F); Cooling water inlet/outlet temperature 30/35 C(86 F /95 F). The design fouling factor for evaporator is 0.076m 2 C/kW(0.000ft 2 F.hr/Btu) and for condenser is 0.044m 2 C/kW( ft 2 F.hr/Btu). 8

10 R34a Flooded (97 to 506 tons) Dimensions Single Compressor (TWXC 00 ~ 300 F3) Cooling water outlet Cooling water inlet C Chilled water inlet Chilled water outlet G K F L H J E B Model B C D E F G H J K L D Unit: TWXC 00 F DN50 TWXC 25 F DN50 TWXC 55 F DN50 TWXC 20 F DN200 TWXC 230 F DN200 TWXC 255 F DN200 TWXC 300 F DN200 Water inlet/ou tlet Dual Compressor (TWXC 340 ~ 50 F3) Cooling water outlet Cooling water inlet C Chilled water inlet Chilled water outlet G K L F H J E B D Model B C D E F G H J K L Unit: TWXC 340 F DN200 TWXC 370 F DN200 TWXC 400 F DN200 TWXC 460 F DN200 Water inlet/ou tlet TWXC 50 F DN200 9

11 Electrical data TWXC_F Standard voltage V 400V 3Ph 50Hz R34a Flooded (97 to 506 tons) Voltage range V 380~45 Max. running current Max. power consumption kw Rated current Compressor Locked rotor mps Max. allowed current Rated current Rated power kw Compressor B Locked rotor mps Max. allowed current Rated current Rated power kw Crankcase heater Voltage V Total input kw Total mps Note:. Customer to specify the exact nominal power supply available on site so that correct electrical components are selected. 2. Main power must be supplied from a single field supplied and mounted fused circuit breaker. 3. The compressor crankcase heaters must be energized for hours before the unit is initially started or after a prolonged power disconnection. 4. ll field wiring must be in accordance with local standards. 5. Neutral line required on 380V-3Ph-50Hz(5 wires) power supply. 6. Rated load amperage values are nominal conditions. 7. ±0% voltage variation from the nominal conditions is allowed temporarily only,not permanently. 0

12 R34a Flooded (97 to 506 tons) Pressure drop Flooded type (Evaporator) Water pressure drop(kpa) Water pressure drop curve (evaporator) Water flow (m 3 /h) TWXC 00F3 TWXC 25F3 TWXC 55F3 TWXC 20F3 TWXC 230F3 TWXC 255F3 TWXC 300 F3 Water pressure drop(kpa) Water pressure drop curve (evaporator) Water flow (m 3 /h) TWXC 340F3 TWXC 370F3 TWXC 400F3 TWXC 460F3 TWXC 50F3 Flooded type (Condenser) 70 Water pressure drop curve (condenser) 40 Water pressure drop curve (condenser) Water pressure drop(kpa) Water pressure drop(kpa) Water flow (m 3 /h) Water flow (m 3 /h) TWXC 00F3 TWXC 25F3 TWXC 55F3 TWXC 20F3 TWXC 230F3 TWXC 255F3 TWXC 300 F3 TWXC 340F3 TWXC 370F3 TWXC 400F3 TWXC 460F3 TWXC 50F3 pplication Range Items pplication range Condenser water entering temperature Evaporator water leaving temperature Water flow volume 25 C~35 C 5 C~5 C Flow volume rating ±20% Temperature difference 4~8 C Fouling factor (m 2. C/kW) Evaporator: 0.076, condenser: Voltage tolerance Voltage rating ±0% Phase tolerance Power supply frequency Evaporator max. working pressure on water side Compressor max. start count Environment quality Drainage system Storage and transport temperature RH(relative humidity) pplicable altitude range ±2% Frequency rating ±2%.0MPa 4 times/h 8times/day Highly corrosive environments and high humidity should be avoided. The height of water drainage should not be higher than the base of the unit. -25 C~55 C In + 40 C does not exceed 50%, + 25 C no more than 90% No more than 000m

13 R34a Flooded (97 to 506 tons) Installation requirements: Be sure to take the base preparation and structure into consideration seriously during installation,particularly on rooftop installations in order to avoid noise and vibration.consulting the building designer before conducting installation is recoended. drainage ditch should surround the base to ensure dewatering occurs. nti-vibration pad is to be placed between the base frame and foundation in order to avoid vibrations and unnecessary noise, and make sure the unit is aclinic during installation Typical Isolation structure nchor Bolt Chiller Frame Base Rubber Pad Steel Base Plate Concrete Base Notes: The maximum altitude difference (levelness) should be within 3 for the chiller base. The base should be raised 00. The installation base of the unit must be concrete or steel structure, which can bear the running weight of the machine. The top should be horizontal. It is ideal to prepare a drainage ditch around installation base. Put the steel plate and anti-vibration pad in the correct position. Finish the installation of the unit and the foundation bolt before secondary concreting. The foundation bolt should protrude 00. Spring isolators are specified on the sales order as an option. Unit bottom Unit bottom Spring shock absorber Foundation Rubber pad Foundation Steel plate (thickness 5) Spring isolator Rubber pad 2

14 R34a Flooded (97 to 505 tons) Isolator Position the absorbers under the unit saddles before final positioning of the unit. The quantity of absorption used for each unit is always decided by the elasticity or durometer value of the absorber. Below please refer to the typical isolation pad and vibration isolator for selection. Typical isolation rubber pad Typical spring isolator 80MM 22MM 70MM 200MM tk 0MM top face 20MM Load value for reference Isolation pad Vibration Isolator Model Minimum load bearing (kg/e) Minimum Quantity Minimum load bearing (kg/e) Quantity TWXC 00 F TWXC 25 F TWXC 55 F TWXC 20 F TWXC 230 F TWXC 255 F TWXC 300 F TWXC 340 F TWXC 370 F TWXC 400 F TWXC 460 F TWXC 50 F Note: () Pads have to extend the full length of the saddle when isolation pads are used. (2) Level the unit to within 5 over its length and width after absorbers are installed. 3

15 Foundation dimensions Drainage ditch R34a Flooded (97 to 506 tons) B E+500 E Evap Centre Line Cond Centre Line L B F R Front side of chiller D D+500 nchor Bolt M20X400 (Provided by user) Nut M20 (Provided by user) Gasket 200 (Provided by user) Chiller Leg Rubber Pad (δ 5) 200X200 Steel Base Plate ( δ 0) 200X50 (Provided by user) X50 Grout concrete after chiller is placed Model TWXC_F3 Dimensions D() E()

16 R34a Flooded (97 to 506 tons) Typical piping system ll piping should be installed independently in order to convey any stress and vibration to the chiller and have sufficient space for maintenance. Water flow switch is required and should be installed on the straight line (5 times the pipe diameter) of the Chilled/Cooling water outlet. It is recoended to install a thermometer and pressure gauge to measure the units operational condition. Notes: The diagram is the recoended water system schematic, some changes may be required to accoodate local conditions. utomatic Watering To Drain ExpansionTank Collector Distributer Flexible connection Check Valve Y-Shape Strainer Pressure Gauge uto vent valve Drain Valve Stop Valve Water Pump Temperature gauge Water Flow Switch 3-Way Valve Suggestion for energy conservation:. Choose the right pressure head for chilled water pump and cooling water pump. Choose proper pipe diameter and water velocity. Minimize pipe joint, reducing joints, pipe reducers, manifolds, and valves unnecessary to reduce local resistance loss. Choose proper water strainer (structure/meshes) and periodically clean. 2. Using a variable frequency water pump is recoended as it can reduce energy consumption by 30%-45%. 3. Using a water distributor and valves between floors or terminal SV to prevent chilled water from circulating in non-working terminals is recoended. 4. Do periodic cleaning of cooling tower and pipe system. 5. Select a location that provides sufficient air-flow for both air-inlet and outlet. 6. Make appropriate adjustments to chilled water inlet/outlet temperature and temperature difference according to the local climate. 5

17 Optional accessories NO. Name Model Instructions Picture Quantity R34a Flooded (97 to 506 tons) Vibration damper reduces vibration and noise by Vibration damper SH series isolating the supports from the 4 floor. Can be installed in the control room through the cable connected to the unit touch screen. It can display all status 2 Remote control cabinet YCKZ-P information and complete all the unit operations(startup/shutdown, error confirm, etc.) Flange connection can be chosen for water pipe 3 Flange JB8/94 Standard flange connection. Customer can choose water side pressure.6mpa according to requirements. 8 Optional items Name Content Power supply 400V 3Ph 50Hz is standard. Water inlet/outlet connection Victaulic type connection is standard for the condenser and evaporator. Flange type connection is optional. High pressure water box Standard water box can sustain.0mpa pressure..6mpa or 2.0Mpa pressure is optional. Chiller vibration isolator Spring isolator and rubber pad are the optional accessories from the factory. Four steps compressor control Stepless compressor control is standard and capacity adjust in four steps is optional. High entering condenser water temperature High entering condenser water entering temperature up to 35 C. Multi unit centralized control Multiple units centralized control is optional (Chiller plant manager). PLC (Prograable Logic Control) The standard electrical controller is Microprocessor and PLC is optional for various applications. Remote control & monitor panel Remote control & monitor panel for easy operation on site. BMS (Building management system) Open protocol RS 485 which is BMS compatible (BCnet or LonWorks). Witness performance testing Factory can arrange testing observation for customers. 6

18 Selection software Selection software Professional selection software makes the product selection process much easier and more efficient than conventional manual selection. Simple operating interface and smart arithmetic greatly improves selection efficiency. The user simply needs to provide several basic parameters, such as cooling capacity, fouling factor, power supply, etc. The program will then display all suitable models for easy selection.this software can be conveniently updated online. If you have any questions please feel free to contact us. We reserve the right to make change in design and construction at any time without notice. 7

19 Head Office TOPIRE SLES & SERVICES SDN BHD ( W) No.7-2-2, Block, Megan Salak Park, Jalan 2/25E, Taman Desa Petaling, 5700 Kuala Lumpur. Tel : (Hunting line) / Fax : tass@topaire.com.my Manufacturer Manufacturer Manufacturer Branches Penang No 4, Lengkok Kikik 2, Taman Inderawasih, 3600, Prai, Pulau Pinang. Tel: / Fax: Johor Bahru No. 62, Jalan Permas Jaya 9/3, Bandar Baru Permas Jaya, 8750 Johor Bahru, Johor Darul Takzim. Tel: / Fax: Kota Bahru Lot 848, Jalan Hospital, Kg. Cherang, Taman Kenangan, 5200 Kota Bahru, Kelantan. Tel: Fax: Melaka DT 3662, Jalan ngkasa Nuri 2, Taman ngkasa Nuri, 7600 Durian Tunggal, Melaka. Tel: Fax: Sabah Lot 2, (DBKK No.69) Lorong Inanam 5 3/4 Miles, Tuaran Road, Kota Kinabalu, Sabah. P.O. Box 526, 88857, Inanam, Kota Kinabalu, Sabah Tel: Fax:

Commercial Air Conditioners 2017/2018

Commercial Air Conditioners 2017/2018 Coercial ir Conditioners 207/208 Water Cooled Screw Chiller Flooded type 340-780kW (R34a) Midea CC Midea CC is a key division of the Midea Group, a leading producer of consumer appliances and provider

More information

Water Cooled Screw Chiller Flooded type kW (R134a) Direct expansion type kW (R22)

Water Cooled Screw Chiller Flooded type kW (R134a) Direct expansion type kW (R22) COMMERCIL IR CONDITIONERS Water Cooled Screw Chiller Flooded type 365-1500kW (R134a) Direct expansion type 255-1490kW (R22) Midea Central ir-conditioner Entering into the 21st century, the energy has increasingly

More information

MODELS LIST. Nominal Capacity RT

MODELS LIST. Nominal Capacity RT 1. MODELS LIST. NOMENCLATURE 3. FEATURES 4. PRODUCT DATA 5. PERFORMANCE CORRECTION 6. ANTIFREEZE 7. INSTALLATION 8. ELECTRICAL DATA 9. SCHEMATIC WIRING DIAGRAM 10.MICROPROCESSOR CONTROLLER 11.APPLICATION

More information

High COP. Water-Cooled Screw Chiller

High COP. Water-Cooled Screw Chiller High COP Water-Cooled Screw Chiller 3 4-7 9 High COP The units are water-cooled chillers, designed from the ground up to meet the needs of today and tomorrow. It is distinguished for its chlorine-free

More information

3 0 H X C A - H P 2

3 0 H X C A - H P 2 3 0 H X C 1 3 0 A - H P 2 Max. Leaving Water Temperature (Heating Mode) 1 for 47 O C,2 for 60 O C Water-to-Water Screw Heat Pump 3 rd Generation Global Water Cooled Chiller Norminal Capacity (USRT) Carrier

More information

30HXC-HP Water-to-water Screw Heat Punp. Nominal cooling capacity: 460~1283 kw Nominal heating capacity: 498~1591 kw

30HXC-HP Water-to-water Screw Heat Punp. Nominal cooling capacity: 460~1283 kw Nominal heating capacity: 498~1591 kw Water-to-water Screw Heat Punp Nominal cooling capacity: 460~1283 kw Nominal heating capacity: 498~1591 kw Carrier China Carrier Corporation is a subsidiary of the United Technologies Corp. (UTC), which

More information

DAIKIN Huizhou Factory Profile

DAIKIN Huizhou Factory Profile DAIKIN Huizhou Factory Profile DAIKIN AIR-CONDITIONING (SHANGHAI)CO.,LTD HUIZHOU FACTORY The manufacture base of central air-conditioner in China Established Daikin group, a wholly owned subsidiary Amalgamated

More information

COMMERCIAL AIR CONDITIONERS M Type Air Cooled Screw Chiller 2012

COMMERCIAL AIR CONDITIONERS M Type Air Cooled Screw Chiller 2012 MCAC-2012-39 COMMERCIAL AIR CONDITIONERS 2012 Commercial Air Conditioner Business Units Midea Air Conditioning and Refrigeration Sector Add: West region of Midea commercial air conditioner department,

More information

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw AIR-COOLED LIQUID CHILLER REVERSIBLE AIR-TO-WATER HEAT PUMP PRO-DIALOG PLUS 30RB/RQ 039S-60S Refrigerant HFC-40A Nominal cooling capacity 40-58 kw Nominal heating capacity 4-59 kw The new generation of

More information

30HXC Nominal cooling capacity kw

30HXC Nominal cooling capacity kw WTER-COOLED SCREW COMPRESSOR LIQUID CHILLERS 0HXC Nominal cooling capacity 286-102 kw The 0HXC units are water-cooled chillers, designed from the ground up to meet the needs of today and tomorrow: - Non-ozone

More information

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut Featuring Ozone-safe HFC134a Hitachi Centrifugal Chillers NEW GXG-S Series GSG-S Series Debut Centrifugal Chiller New GXG-S, GSG-S Series Debut High-efficiency New series Centrifugal Chillers that use

More information

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut Featuring Ozone-safe HFC134a Hitachi Centrifugal Chillers NEW GXG-S Series GSG-S Series Debut Centrifugal Chiller New GXG-S, GSG-S Series Debut High-efficiency New series Centrifugal Chillers that use

More information

Modular Water Cooled Water Chiller

Modular Water Cooled Water Chiller Modular Water Cooled Water Chiller Shandong Vicot Air Conditioning Co., Ltd. Shandong Vicot Air Conditioning Co., Ltd. is one of the major players in the Chinese air conditioning industry, specialized

More information

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated. NOMENCLATURE INTRODUCTION The HTT HWDX water-cooled chillers range is the latest addition to HTT s growing family of commercial products, featuring the most current technologies advances. The HWDX main

More information

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE -

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE - HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE - Nominal Cooling Capacity Range 112 kw to 1,080 kw at 50Hz 32 USRT to 307 USRT at 50Hz 96,320 kcal/h to 928,800 kcal/h at 50Hz 382,000 Btu/h to 3,685,000

More information

.2 Section Waste Management and Disposal.

.2 Section Waste Management and Disposal. Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump Engineered for flexibility and performance. TM MHS-R134a-2012 Pathfinder ir-ooled Single-Screw hiller/heat Pump Super-high-efficiency series : MHS105-MHS348 ooling capacity: 393 kw 1334 kw Heating capacity:

More information

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly. HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types

More information

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: 40-158 kw Nominal heating capacity: 41-159 kw Carrier China Carrier Corporation is a subsidiary of the United Technologies

More information

ERACS.C-N Higher efficiency air-cooled screw pump

ERACS.C-N Higher efficiency air-cooled screw pump ELITE TM Series COOLING ERACS.C-N Higher efficiency air-cooled screw pump HEATING HOT WATER Cooling Capacity:5~1341 (7~381 Tons) Heating Capacity:60~1363 (74~388 Tons) High Efficiency Air-cooled Heat Pump

More information

Power Supply RT. Model. Ph, V, Hz 54 LSBLG190H-M 3,380~415V,50 85 LSBLG290H-M 3,380~415V,50 92 LSBLG325H-M. Model Name 3,380~415V, LSBLG430H-M

Power Supply RT. Model. Ph, V, Hz 54 LSBLG190H-M 3,380~415V,50 85 LSBLG290H-M 3,380~415V,50 92 LSBLG325H-M. Model Name 3,380~415V, LSBLG430H-M 1. MODELS LIST 1. NOMENCLATURE 3 3. FEATURES 3 4. PRODUCT DATA 6 5. PERFORMANCE CORRECTION 9 6. ANTIFREEZE 1 7. INSTALLATION 13 8. ELECTRICAL DATA 16 9. ELECTRICAL DIAGRAM 17 10. SCHEMATIC WIRING DIAGRAM

More information

Hitachi Centrifugal Chillers

Hitachi Centrifugal Chillers Featuring Ozone-safe HCF134a Hitachi Centrifugal Chillers HC-F-GXG Higher-efficiency Type ARI temperature condition JIS temperature condition 1,463 kw to 4,571 kw (416 USRT to 1, USRT) 1,407 kw to 4,395

More information

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed

More information

19DV Back-to-Back Centrifugal Liquid Chiller with PUREtec TM Refrigerant and Greenspeed TM Intelligence

19DV Back-to-Back Centrifugal Liquid Chiller with PUREtec TM Refrigerant and Greenspeed TM Intelligence 19DV Back-to-Back Centrifugal Liquid Chiller with PUREtec TM Refrigerant and Greenspeed TM Intelligence 19DV Two-stage: 600-800Ton (Air-conditioning Low voltage VFD) Turn To The Experts Inheriting a rich

More information

OIL FREE CENTRIFUGAL CHILLER

OIL FREE CENTRIFUGAL CHILLER OIL FREE CENTRIFUGL CHILLER OIL FREE CENTRIFUGL CHILLER High Efficiency Energy saving and high efficiency The unit adopts the turbo inverter compressor technology and frictionless technology, which will

More information

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: , DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: +971-6-5432526, Fax#: +971-6-5432415, Email: dolcool@emirates.net.ae, web site: www.dolphinheattransfer.com NOMENCLATURE: INTRODUCTION DOLCOOL branded

More information

Leadership, Innovation, Advanced Technology Synergise Here!

Leadership, Innovation, Advanced Technology Synergise Here! Cooling Synergies Leadership, Innovation, Advanced Technology Synergise Here! 125 years of Engineering Innovation Kirloskar Chillers is proud to be a part of 125 years old Kirloskar Group. The diversified

More information

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series Centrifugal Chiller High Efficiency Centrifugal Chiller HC-F-GFG-SSC Series (Super High Efficiency Type) HC-F-GXG-S

More information

Water-cooled Centrifugal Chiller

Water-cooled Centrifugal Chiller KMC Series Water-cooled Centrifugal Chiller 1795-4923kW(500RT-1400RT) R-134a Contents Nomenclature... 1 Unit features... 1 Computerized control... 3 General technical data... 4 Electrical data... 6 Dimension

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

ARV.

ARV. ARV www.coldinnovation.it 1 INDEX Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R134a...pag. 5 Semi-hermetic screw compressor...pag.

More information

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-to-Water Heat Pump

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-to-Water Heat Pump 0RB/RQ ir-cooled Liquid Chiller Reversible ir-to-water Heat Pump Nominal cooling capacity: 9-76 kw (0RB) Nominal cooling capacity: 6-0 kw (0RQ) Nominal heating capacity: 89-0 kw (0RQ) Turn To The Experts

More information

T-16DNH E. DOUBLE EFFECT DIRECT FIRED ABSORPTION CHILLER Cooling Capacity: USRt Heating Capacity: kw

T-16DNH E. DOUBLE EFFECT DIRECT FIRED ABSORPTION CHILLER Cooling Capacity: USRt Heating Capacity: kw T-16DNH-0806-01E DOUBLE EFFECT DIRECT FIRED ABSORPTION CHILLER : 1350 USRt Heating Capacity: 374 3370 kw Carrier makes the world a better place to live by creating a comfortable, productive and healthy

More information

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW Row Cooling Precision Air Conditioner Cooling Capacity: 26.2kW~68.6kW CHILLROW is installed closely with the server cabinets and refrigerating independently. The

More information

MAC-A R410A Series Air cooled Modular Chiller

MAC-A R410A Series Air cooled Modular Chiller Catalogue MAC R410A 2011(60Hz) MAC-A R410A Series Air cooled Modular Chiller Model: Refrigerant: Co ling Capacity: MAC210A5 R410A 72kW Overview Based on the successful McQuay air-cooled modular chiller,

More information

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

HYDROCIAT LW R407C. Water cooled chillers USE RANGE Screw compressors CIAT dry direct expansion shell and tubes evaporator HPS equipment (High Power System) cooling or heating Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C Product Data 30RQ Air-cooled Modular Chiller R22 & R410A & R407C Introduction Air-cooled modular chiller is a kind of central airconditioning unit which adopts air as the cooling (or heating) source and

More information

DAIKIN Modular Inverter Air Cooled Chiller

DAIKIN Modular Inverter Air Cooled Chiller DAIKIN Modular Inverter Air Cooled Chiller R410A ODP=0 R410A ODP=0 R410A ODP=0 R410A ODP=0 1 EVOLUTION ULTIMATE DAIKIN has achieved a wealth of world s firsts over the last three centuries. Based on four

More information

Air Cooled Scroll Chiller

Air Cooled Scroll Chiller Air Cooled Scroll Chiller Midea chillers use H shape heat at air side and single unit s capacity from kw to 0kW. Super chillers are divided to SS,SS-LA, SP-LA and SP-HMLA series according to their water

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

Midea R134a 50Hz l Flooded type water cooled screw chiller (PCB Control)

Midea R134a 50Hz l Flooded type water cooled screw chiller (PCB Control) DM15-01.01.18en Midea R134a 50Hz l Flooded type water cooled screw chiller (PCB Control) Applicable Model: MWSC340A-FB3 MWSC440A-FB3 MWSC540A-FB3 MWSC690A-FB3 MWSC805A-FB3 MWSC890A-FB3 MWSC1080A-FB3 MWSC1200A-FB3

More information

WATE R -C OOLE D WATE R C H ILLE R S

WATE R -C OOLE D WATE R C H ILLE R S WATE R -C OOLE D WATE R C H ILLE R S R40A / R407C / R Standard Type Heat Recovery Type Brine Type ISO 900 ISO 400 Printed in Japan (H) HR-E590S Sep. 0 Water-cooled Chillers Advanced air conditioning solutions

More information

Call us today! (800)

Call us today! (800) 500 TON AIR-COOLED CHILLER PA-ACCTR-500 Call us today! (800)341-4297 The 500-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

30KAV Variable Speed Air-cooled Screw Chiller

30KAV Variable Speed Air-cooled Screw Chiller 0KAV Variable Speed Air-cooled Screw Chiller Turn To The Experts Founded by the inventor of modern air conditioning, Carrier is the world s leader in high-technology heating, air-conditioning and refrigeration

More information

Call us today! (800)

Call us today! (800) 150 TON AIR-COOLED CHILLER PA-ACCTR-150 Call us today! (800)341-4297 The 150-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

30HXC - 50 HZ. Water-Cooled Screw Compressor Liquid Chillers. Nominal cooling capacity kw

30HXC - 50 HZ. Water-Cooled Screw Compressor Liquid Chillers. Nominal cooling capacity kw Water-Cooled Screw Compressor Liquid Chillers Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. 0HC - 50 HZ Nominal

More information

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS R Products That Perform...By People Who Care FORM NO: MS0455A WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS R134a HXWC SERIES 205 to 560 Tons 60Hz INTRODUCTION Dunham-Bush's HXWC water cooled

More information

Call us today! (800)

Call us today! (800) PA-ACCTR-200 Call us today! (800)341-4297 The 200-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable, efficient and quiet chiller

More information

AZ(P)Y1 SERIES. Johnson Controls - Hitachi Air Conditioning AIR COOLED SCREW TYPE-WATER CHILLERS. R134a. Manufactured by:

AZ(P)Y1 SERIES. Johnson Controls - Hitachi Air Conditioning AIR COOLED SCREW TYPE-WATER CHILLERS. R134a. Manufactured by: Johnson Controls - Hitachi Air Conditioning Manufactured by: Johnson Controls-Hitachi Wanbao Air Conditioning (Guangzhou) Co.,Ltd. Address:No.110.ChengAo East Road, Conghua,Guangzhou City, Guangdong Province,China

More information

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient PRODUCT SELECTION DATA Easy and fast installation Compact, reliable and efficient Class A variable speed circulator available Air-Cooled Liquid Chillers 0RB 008-015 CARRIER participates in the ECP programme

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

30GX - 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

30GX - 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER 30G - 50 Hz Nominal cooling capacity 384-03 kw The 30G units are air-cooled chillers, designed from the ground up to meet the needs of today and

More information

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION 100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest

More information

Water-Cooled Dual Compressor Screw Chiller

Water-Cooled Dual Compressor Screw Chiller Installation Manual IM 692-1 Group: Chiller Part Number: 629955 Effective: May 1997 Supersedes: IM663-1 IM683 IM692 Water-Cooled Dual Compressor Screw Chiller Installation Manual PFS 155C through PFS 210C,

More information

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a Air-Cooled Variable Speed Drive Screw Chillers Super Efficient Super Quiet Cooling Capacity Range 540-1405 kw R134a World s first low sound Air-Cooled variable speed drive screw chiller The recognition

More information

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump 30RB: Nominal cooling capacity: kw 30RQ: Nominal cooling capacity:

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump 30RB: Nominal cooling capacity: kw 30RQ: Nominal cooling capacity: 0RB/RQ ircooled Liquid Chiller Reversible irtowater Heat Pump 0RB: Nominal cooling capacity: 159758 0RQ: Nominal cooling capacity: 160 Nominal heating capacity: 1895 Features The quasnap Puron liquid chillers/airtowater

More information

The High-efficiency Air-cooled Chiller "H series"

The High-efficiency Air-cooled Chiller H series R07C NEW The High-efficiency Air-cooled Chiller "H series" The air-cooled chiller "H series" with improved efficiency and functionality by several advanced technologies. This series with the world's best

More information

Outstanding Performance; Application Flexibility

Outstanding Performance; Application Flexibility PORTLE HILLER4EP2 SERIES Outstanding Performance; pplication Flexibility EP2 Series Portable hillers are designed for 4 to 43 ton applications. Units are available in air-cooled, water-cooled and remote

More information

Hi-Pres Cooling Products Catalogue. Product Catalogue

Hi-Pres Cooling Products Catalogue. Product Catalogue Hi-Pres Cooling Products Catalogue Product Catalogue Important Notice This document is provided As is and is subject to change without prior notice. Novenco A/S reserves this right due to continuous product

More information

AQUASNAP JUNIOR 30RHV

AQUASNAP JUNIOR 30RHV High-Efficiency Air-To-Water Heat Pumps Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. AQUASNAP JUNIOR 3RHV 6-11

More information

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.

More information

Conditioning your ambient, maximising your comfort.

Conditioning your ambient, maximising your comfort. High efficiency water cooled chillers, heat pumps and evaporating units with screw compressors and R134a refrigerant gas. Cooling capacity 378 1554 kw Heating capacity 425 1744 kw Cooling capacity evaporating

More information

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

INVERTER SCROLL. LG Electronics     Distributed by. Copyright 2017 LG Electronics. All rights reserved. LG Electronics http://www.lg.com http://partner.lge.com Distributed by Copyright 2017 LG Electronics. All rights reserved. FEATURES & BENEFITS High Efficient Inverter Technologies EER 2.65 / COP 3.2 /

More information

Modular Air Cooled Scroll Chillers

Modular Air Cooled Scroll Chillers Modular Air Cooled Scroll Chillers 65 80 130 Find out more at www.greeonline.com 160 249 High Efficiency Shell and Tube Heat Exchanger The Gree D Series Chillers utilise high efficiency shell and tube

More information

CASE STUDY AIR-CONDITIONERS

CASE STUDY AIR-CONDITIONERS CASE STUDY AIR-CONDITIONERS An Investment in Longer Lasting Quality ABOUT US BT Commercial Ltd. is a dynamic and diversified company, which has been in operation since 1992. Our company, which is growing

More information

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump Catalogue MAC-D-2013 (50Hz) MAC-D R410A Series Air-cooled Modular Chiller/Heat pump Model: Refrigerant: Cooling Capacity: Heating Capacity: MAC210D5-MAC1680D5 MAC230D5-MAC1840D5 MAC210DR5-MAC1680DR5 MAC230DR5-MAC1840DR5

More information

Air-Cooled Condensing Units with Compact Screw Compressors

Air-Cooled Condensing Units with Compact Screw Compressors LK-SCUTB March 2015 Air-Cooled Condensing Units with Compact Screw s Technical Bulletin Models SSV DSV Table of Contents Nomenclature Chart... 2 Introduction... 3 Bitzer TM s... 4 Magnum TM Microprocessor...

More information

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview Product overview 1 Company Profile Yantai Oceanair Refrigeration & Air-Conditioning Co.,Ltd. was established in 2004 and has been listed on the New OTCBB (Stock Code: 831870). We are mainly specialized

More information

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e. ORTEC Compressed Air, Gas & Fluid Technologies t a l r o n m e n i l y E n v F r i e n d t r a n l y R e i g e f r INDUSTRIAL FLUID CHILLERS FC SERIES (0-00 TONS) Application Flexibility Nortec Industrial

More information

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X Product Data Catalog Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X Variable Speed Total Access Modules MS010W, MS020W, MS030W, MS050W MS010V, MS020V,

More information

H4T R410A. refrigerant

H4T R410A. refrigerant H4T INDEX Polyvalent unit working modes...pag. 4 Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R410A...pag. 5 Scroll compressors...pag.

More information

Water-cooled chillers with High Speed Centrifugal Compressors

Water-cooled chillers with High Speed Centrifugal Compressors Water-cooled chillers with High Speed Centrifugal Compressors Refrigerant R134a 190-760 (395 to 2660 kw) Refrigerant R1234ze 135 G - 505 G (310 to 1820 kw) Table of Contents Introduction...3 Features and

More information

The High-efficiency Water-cooled Chiller "H series"

The High-efficiency Water-cooled Chiller H series R07C NEW The High-efficiency Water-cooled Chiller "H series" The Water-cooled chiller "H series" with improved efficiency and functionality by several advanced technology. This series with the world's

More information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER

More information

30GK. Air-Cooled Liquid Chillers. Nominal cooling capacity kw

30GK. Air-Cooled Liquid Chillers. Nominal cooling capacity kw Air-Cooled Liquid Chillers Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. 30GK Nominal cooling capacity 238-725

More information

GENERAL TABLE OF CONTENTS NOMENCLATURE DCLC D V

GENERAL TABLE OF CONTENTS NOMENCLATURE DCLC D V GENERAL From the beginning of 20 th Century, DB has been providing innovative solutions for the heating, air conditioning and refrigeration needs of its customers. Today s global company has a proud heritage

More information

Chiller Manufacturer should have been manufacturing chillers utilizing magnetic bearing, oil free technology for more than 10 years.

Chiller Manufacturer should have been manufacturing chillers utilizing magnetic bearing, oil free technology for more than 10 years. TURBOCOR COMPRESOR CHILLERS General Description Microprocessor controlled, water chiller using HFC 134a refrigerant, two stage centrifugal oil free variable speed compressor's and electronic expansion

More information

Innovation for a Better & Greener Future

Innovation for a Better & Greener Future Innovation for a Better & Greener Future Comprehensive range of Water Cooled Variable Speed Centrifugal Chillers with Magnetic Bearing Compressors Kirloskar Chillers, a future-focused organisation, has

More information

MODULAR CHILLER. R410a R22

MODULAR CHILLER. R410a R22 Ra R 3 Ra/-0 R/-0 New ppearance New Y-shape design, more fashion IR-COOLED SERIES (Ra) Compressor ir cooling side heat exchanger Best scroll compressor, low sound power level, By using calculation model

More information

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 46 Above picture is only indicative and is not binding AIR FC The packaged air cooled chillers of RAS Kp series are suitable

More information

Chilled Water Precision Air Conditioner for Critical Application

Chilled Water Precision Air Conditioner for Critical Application AIRSYS-P-SC-OPTIMA-HD-E14507V01.3 HD Chilled Water Precision Air Conditioner for Critical Application Cooling Capacity: 42.1kW~180.9kW OPTIMA product family is designed for medium to large data center.

More information

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES 60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

Nirvana. Cycling Refrigerated Dryers

Nirvana. Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Reliability Is Our Design Ingersoll Rand's Nirvana Cycling Refrigerated Dryer provides reliability like no other dryer in its class:

More information

MEDICAL CHILLER SYSTEMS

MEDICAL CHILLER SYSTEMS Mission Critical Chilled Water Systems Engineered to Exacting Standards Magnetic Resonance Imaging Systems CT Scanners Oncology Linear Accelerators Blood Cooling Systems Precise Laboratory Applications

More information

1

1 ST www.coldinnovation.it 1 INDEX Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R410A...pag. 5 Scroll compressors...pag. 6 Condenser

More information

HYDROCIAT LW. Use. Range. Water chillers Heat pump. Cooling capacity kw Heating capacity kw. HYDROCIAT LW, ST series

HYDROCIAT LW. Use. Range. Water chillers Heat pump. Cooling capacity kw Heating capacity kw. HYDROCIAT LW, ST series Energy excellence Compact and reliable Screw compressors Flooded shell and tubes evaporator Self-adjusting electronic control Touch screen control interface Cooling capacity 273-1756 kw Heating capacity

More information

SYSTEM DESIGN REQUIREMENTS

SYSTEM DESIGN REQUIREMENTS P a g e 1 SYSTEM DESIGN REQUIREMENTS WFC-S SERIES WATER-FIRED SINGLE-EFFECT ABSORPTION CHILLERS / CHILLER-HEATERS Yazaki WFC-S Series water-fired chillers and chiller-heaters are available with nominal

More information

SINGLE SCREW AIR COOLED CHILLER-HEAT RECOVERY

SINGLE SCREW AIR COOLED CHILLER-HEAT RECOVERY MHS-F HR-2011 SINGLE SCREW AIR COOLED CHILLER-HEAT RECOVERY MODEL: MCS050.1-380.2FSP MHS050.1-380.2FSP MHS050.1-235.2FSR COOLING CAPACITY: 164KW-1370KW HEATING CAPACITY: 172KW-1439KW PARTIAL HEAT RECOVERY:

More information

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics     Distributed by 4mm 이상 ~ 15mm 미만 (음화형 규정) LG Electronics http://www.lg.com http://partner.lge.com Copyright 2017 LG Electronics. All rights reserved. Distributed by FEATURES & BENEFITS High Efficient Inverter Technologies

More information

30RB /30RQ

30RB /30RQ AIR-OOLE LIQUI HILLER REVERSIBLE AIR-TO-WATER HEAT PUMP PRO-IALOG PLUS * Unit with low noise option 30RB9-80/30RQ0-46 Refrigerant HF-40A Nominal cooling capacity 93-78 kw Nominal heating capacity 7-0 kw

More information

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F Temperature Control Units Water & Oil - F Portable Chillers Air & Water-Cooled - 7 F Central Chillers Air & Water-Cooled Packages & Modules - 7 F Pump Tank Stations Chilled or Tower Water - gallons Cooling

More information

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the

More information

TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series

TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series Absorption Chillers TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series Stable Chilled Water Outlet Temperature PID control is applied to maintain constant chilled water outlet temperature. When the cooling

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly