Electron Microscopy Sciences

Size: px
Start display at page:

Download "Electron Microscopy Sciences"

Transcription

1 Electron Microscopy Sciences INSTRUCTIONAL MANUAL CAT Explosion Proof Hot Plate Stirrer Model SF87325 P.O. Box 550 s1560 Industry Road s Hatfield PA 19440

2 1 Safety Symbols Used in this Instruction Manual This manual contains important safety and operating information. Read carefully and understand the entire contents of this manual prior to the use of this equipment. Safety Symbols and their meanings: Note Notes alert you to pertinent facts and conditions. Caution Cautions alert you to a possibility of damage to the equipment. Warning Warnings alert you to various hazards such as explosion, risk of fire and/or the possibility of personal injury. Hot Surface Hot surfaces alert you to a possibility of personal injury if you come in con tact with a surface during use or for a period of time after use. Electrical Shock Hazard This alerts you to a possibility of electrical shock. Introduction The Explosion-Proof Stirring Hot Plate is UL listed and meets OSHA and other safety standards. It is used for applications requiring temperatures from 38 C (100 F) to 218 C (424 F). The unit consists: A heated aluminum top plate An adjustable electronic temperature control An adjustable electronic stirring speed control The unit meets these requirements: UL Listed for Class I, Group C, and D hazardous atmospheres Safe in hazardous situations where Class I, Group C and D flammable gases or solvent vapors can produce explosive or ignitable mixtures UL listed explosion proof; meets IEC1010 laboratory standard Thermostatic control Over-temperature safety control Product Highlights Stir solutions with a viscosity of 1200 cps at 400 rpm at 21.5 C Large, aluminum top plate surface 9.1" x 9.1" (23.2 cm x 23.2 cm) provides efficient heat transfer and excellent temperature uniformity. (Uniformity of top plate at 70 C (158 F) is ±2 C (±4 F) Electronic temperature control. Temperature range from 38 C to 220 C (100 F to 428 F) Precise electronic heat control maintains temperature stability within ±2 C (±4 F) Automatic over temperature safety switch cuts power to unit if top plate temperature exceed 280 C Sturdy construction allows maximum load capacity on top of the plate (25 lb or 11.3 kg) Stainless steel case is easily cleaned and maintained Designed for sparkless, hardwired connection. Unit has 45.7 cm lead wire and conduit attachment Optional dial thermometer, with 0 C to 300 C range, fits directly into top plate and measures surface temperature Meets all CE, UL and CUL standards Applications Heat and stir flammable chemicals or solvents (Class I, group C & D) Heat-treat and uniformly mix coatings Silicon wafer etching Quality control test viscosity of oil and water/organic content analysis

3 2 General Warnings Electrical Shock Hazard This unit must be installed by a qualified, skilled electrician familiar with installing explosion-proof electrical equipment in order to ensure compatibility of unit specifications to power source and grounding compliance. Warnings DO NOT use product for anything other than its intended use. DO NOT use metal foil on stirring hot plate. Use only with glass or stainless steel vessels. If using unit in hazardous atmospheres, keep enclosure chambers tightly sealed at all times to reduce the risk of ignition. Any maintenance or servicing of the unit should be done by a skilled professional or risk of personal injury may occur. General Specifications and Environmental Conditions General Specifications for the Explosion-Proof Stirring Hot Plate, Model SF87325 Dimensions Top plate Dimensions Overall (W x H x D) Weight Electrical ratings 9.13 x 9.13 (23.2 x 23.2 cm) 10 x 8.13 x (25.4 x 20.8 x 32.4 cm) 29 lb (13.2 kg) 120 volts 8.9 Amps 1,070 Watts Note The Explosion Proof Hot Plate Stirrer is UL listed explosion-proof for Class I, Division I, Group C and D locations where flammable gases or vapors are present in sufficient quantities to produce explosive or ignitable mixtures. The Group C and D classification specifies hazardous atmospheres containing either flammable gases or vapors of flammable liquids (see NFPA 497 and NFPA 321). Phase 1 Frequency 60 Maximum Load for top plate 25 lb (11.3 kg) Maximum temperature 218 o C (424 o F) Stirring speed range rpm Environmental Conditions Operating ambient temperature: 17 o C to 27 o C (63 o F to 81 o F) Relative humidity: 20% 80% (non-condensing) Storage: -25 o C to 65 o C (-13 o F to 81 o F) Relative humidity: 10% 85% (non-condensing) Altitude Maximum: 1.24 miles (2 km) Main supply voltage Maximum fluctuation: 10%; Installation category: 2; Pollution degree: 2

4 3 Hazardous Atmospheres Summary (partial listing) This table is intended to cover some of the chemicals/atmospheres designated as Class I, Group C and Group D in accordance with the National Electric Code, National Fire Protection Association (NFPA 70). This is not a complete list. For a more complete list of flammable chemicals, gases, vapors and dusts for electrical equipment in hazardous (classified) locations, go online to org and search NFPA 497. Warning To reduce the risk of fire or explosion, do not operate or install the Explosion-Proof Stirring Hot Plate where the marked operating temperature (T2A, 280 C) exceeds the ignition temperatures of the chemical vapors/hazardous atmospheres present. Group Chemical/Atmosphere Ignition Temperatures C Acetaldehyde 175 C, 347 F C Diethyl Ether 160 C, 320 F C Ethylene 450 C, 842 F C Unsymmetrical Dimethyl Hydrazine (UDMH) 249 C, 480 F D Acetone 465 C, 869 F D Acrylonitrile 481 C, 898 F D Ammonia 498 C, 928 F D Benzene 498 C, 928 F D Butane 288 C, 550 F D 1-Butanol 343 C, 650 F D 2-Butanol 405 C, 761 F D n-butyl Acetate 421 C, 790 F D Cyclopropane 503 C, 938 F D Ethane 472 C, 882 F D Ethanol 363 C, 685 F D Ethyl Acetate 427 C, 800 F D Ethylene Dichloride 413 C, 775 F D Gasoline C, F D Heptane 204 C, 399 F D Hexane 225 C, 437 F D Isoamyl Alcohol 350 C, 662 F D Isoprene 220 C, 428 F D Methane (Natural Gas) 630 C, 999 F D Methanol 385 C, 725 F D Methyl Ethyl Ketone 404 C, 759 F D Methyl Isobutyl Ketone 440 C, 840 F D 2-Methyl-1-Propanol 416 C, 780 F D 2-Methyl-2-Propanol 478 C, 892 F D Naptha (Petroleum Naptha) 288 C, 550 F D Pyridine 482 C, 900 F D Octane 206 C, 403 F D Pentane 243 C, 470 F D 1-Pentanol 300 C, 572 F D Propane 450 C, 842 F D 1-Propanol 413 C, 775 F D 2-Propanol 399 C, 750 F D Propylene 455 C, 851 F D Styrene 490 C, 914 F D Toluene 480 C, 896 F D Vinyl Acetate 402 C, 756 F D Vinyl Chloride 472 C, 882 F D Xylenes C, F

5 4 Unit Placement Electrical Shock Hazard This unit must be installed by a qualified, skilled electrician familiar with installing explosion-proof electrical equipment in order to ensure compatibility of unit specifications to power source and grounding compliance. Grounding requirements for hazardous areas are specified in Article 501 (and Article 250) of the National Electrical Code. Also, consult local electrical code requirements. All units are provided with an equipment grounding lead that should be used as the primary equipment ground connection for the unit. Cautions The Explosion-Proof Stirring Hot Plate is shipped with a wooden shipping support attached to the bottom that needs to be removed prior to permanent installation. Minimum allowable spacing between stirring hot plate and any vertical surface is one inch (2.54 cm). DO NOT install where the marked operating temperature exceeds the ignition temperature of the hazardous atmosphere(s) in order to reduce the risk of fire or explosion. Requirements The Explosion-Proof Stirring Hot Plate is designed for permanent installation. Permanent installation is made possible with integral mounting lugs and 1/2 (1.3 cm) conduit with 18 (45.7 cm) of lead wire provided. Allow space for ventilation. Electrical specifications are located on the back of the stirring hot plate. Consult customer service ( ) if your electrical service is different than that listed on the specification plate. The Explosion-Proof Stirring Hot Plate leads are factory sealed to meet the requirements of Article 501 of the National Electrical Codes (NEC). The Explosion-Proof Stirring Hot Plate must be hardwired per NEC (USA) or CEC (Canada) requirements. The installation must conform with installation requirements for electrical equipment intended for use in Class I, Group C and D hazardous locations as defined by the NEC and electrical code requirements of your area. Install on a level, sturdy surface. An external switch or circuit breaker needs to be included in the building installation in close proximity of the unit as a means to disconnect supply circuit. Over-current protection devices should be included in the installation. The unit can be connected to a branch circuit not exceeding 20 Amps. Operation Warning To reduce the risk of personal injury, DO NOT use this product for anything other than its intended purpose. The top plate uses a tubular heating element cast into an aluminum top plate. A primary electronic feedback control is used to regulate and limit the temperature of the plate under normal operating conditions. Should the primary electronic control fail, there is a secondary, bimetallic thermostat that controls the temperature. The secondary control will limit the top plate temperature to 280 C (536 F). An electronic control regulates the stirring speed. The stirring motor is enclosed in an explosion-proof casing. Together, the motor and a strong magnet provide excellent miscibility when used with a stir bar. The aluminum, explosion-proof enclosure houses all control and electrical connections.

6 Heating Specifications for Cast-in Tubular Heating Element Cautions Maximum load of the top plate is 25 lb (11.3 kg). The aluminum top plate is easily stained. Clean by wiping the top plate using a non-abrasive cloth lightly dampened with water. DO NOT use a wire brush to clean the unit. Using a wire brush will modify the integrity of the surface and it could affect your heat stability. Heating Metal Vessels Note Dial marks for heat control knob settings are for reference only. The dial marks indicate approximate hot plate temperature in C (±15 C). It takes 60 minutes for a one liter flask, filled with 600 ml of water, to vigorously boil when the maximum set point is 230 o C (446 o F). Hot Surface Caution: Hot Surface. Avoid Contact. The top plate will remain hot for some time after the unit is turned off without any visual indications that it is still hot. 5 Metal vessels may be heated safely on the unit without the danger of the vessel reflecting enough heat back to the top to cause the aluminum to soften. The internal electronic control will regulate the aluminum top plate temperature. Heating Specifications Temperature range at the center of hotplate 38 C C ± 3 C Temperature cut-off 235 C ± 9 C Setting the Temperature Turn the Dial Control Switch clockwise to the desired temperature. Dial marks indicate approximate surface temperature in C. When the temperature for a given dial setting has been reached, the control will regulate the hot plate. To turn OFF hot plate, turn dial switch fully counterclockwise to the OFF position. Heat-up time to maximum temperature (218 C, unloaded top plate) Temperature stability at center of top plate surface at 70 C: Temperature stability at center of top plate surface at 218 C Uniformity of top plate surface at 70 C (center to 1 or 2.54 cm from corners) Uniformity of top plate surface at 218 C (center to 1 or 2.54 cm from corners) 16.5 minutes at nominal voltage ±1 C ±3 C ±2 C ±10 C Warning To prevent ignition of hazardous atmospheres, the aluminum explosion-proof enclosure chambers must be kept closed, with screws securely tightened, whenever the unit is in operation and/or connected to power supply circuit. Temperature cycling over a temperature range greater than 5 C with a period of approximately 6 minutes may be observed when operating unit at 220 C or higher. If such cycling is observed, the unit is functioning under abnormal or fault conditions and the secondary bimetallic thermostat is controlling the top plate temperature. If this occurs, do the following: 1. Turn unit OFF at both the heat and stir dial switches and the external circuit breaker 2. Allow unit to cool completely. 3. In an atmosphere absolutely free of flammable liquids, gases, and/or vapors, test the heat control function of the unit at several temperature settings within the range of 38 C to 220 C. If the top plate temperature of the unit again cycles with a period of approximately 6 minutes over a temperature range greater than 5 C when ramping to or operating at 220 C, call customer service at To prevent ignition of hazardous atmospheres, do not use electrical equipment such as a thermocouple or pyrometer to monitor the hot plate temperature unless it is UL listed for the same hazardous atmospheres and temperature rating as the unit. The thermocouple and pyrometer could serve as a source of ignition.

7 Stirring Speed Specifications 6 Note Speed range is rpm, dependent upon viscosity of solution used. Stability of the stirring speed setting using a 4 liter flask with 2 liters of water is ±3 rpm. Maximum flask size is 4 liters. Dial marks for speed control knob settings indicate approximate RPMs only (±20 rpm). Setting the Stirring Speed The power switch for the stirrer is turned ON/OFF by using the stir dial switch. Power is ON when stir dial is turned clockwise, past the zero OFF mark (0). To set the stir control to desired speed, tum dial switch clockwise until the dial pointer is aligned with the selected dial mark (indicating rpms). Stirring Speed Guide Flask Size 1 L Stir Bar Size Amount of Solution 1 L ml Viscosity Maximum Speed* 600 ml Water 1,200 rpm 1 L 600 ml Corn oil 1,200 rpm 500 ml 350 ml 30 weight motor oil 1,265 centipoise viscosity std. 950 rpm 400 rpm *Maximum speed obtained without the stir bar losing coupling with the Plate magnet. 1 L 350 ml Light corn syrup 70 rpm Resetting the Stirring Motor When the Over-Current Protection Device is Activated The stirring motor is equipped with an over-current protection device. Should this device be activated, the stirring motor will shut off. To reset the motor: 1. Turn unit OFF at both the dial power switches and the external circuit breaker. 2. Allow unit to cool. 3. Turn the external circuit breaker back on. If the over-current protection device is repeatedly activated during normal operation, please call Customer Service at Maintenance Cautions The unit does not contain serviceable parts. Repairs should not be performed on this product, due to the risk of the ignition of hazardous atmospheres. Due to the nature of this product, operator safety will be endangered should maintenance or servicing be performed on it by the operator.

8 Electron 7 Microscopy Sciences For any questions or for ordering information, please contact Customer Service at Thank you for choosing! P.O. Box Industry Road, Hatfield, PA 19440

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate OPERATION MANUAL SERIES 873 UL Listed for Class I, Group C and D Hazardous Locations Model # Voltage Description SP87325 120 9.13 X 9.13 (23.2

More information

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate BARNSTEA THERMOLYNE CORPORATION Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate OPERATION MANUAL SERIES 873 UL Listed for Class I, Group C and Hazardous Locations Model # Voltage escription

More information

Explosion-proof Duct Heaters

Explosion-proof Duct Heaters Safety INDEECO explosion-proof ULTRA-SAFE and EP2 duct heaters are Factory Mutual (FM) and CSA Approved. The ULTRA-SAFE duct heater has the only standard product offering and features the industry s lowest

More information

FACT SHEET Program: Lab Fire Safety

FACT SHEET Program: Lab Fire Safety REFRIGERATION/FREEZING OF FLAMMABLE LIQUIDS Fires and explosions can and do occur in either general-purpose laboratory or ordinary domestic refrigerators or freezers when these types of appliances are

More information

SAFETY APPROVED FLASHLIGHTS: UNDERSTANDING THE REQUIREMENTS INTRODUCTION & OVERVIEW

SAFETY APPROVED FLASHLIGHTS: UNDERSTANDING THE REQUIREMENTS INTRODUCTION & OVERVIEW SAFETY APPROVED FLASHLIGHTS: UNDERSTANDING THE REQUIREMENTS INTRODUCTION & OVERVIEW Any flashlight that is intended to be used in a hazardous location must be tested and approved for that use because it

More information

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS TECHNICAL NOTE s for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS The DataFID and MicroFID II are portable flame ionization detectors designed to monitor volatile organic

More information

Instruction Manual. Mini Hotplate Mini Stirrer Mini Hotplate Stirrer

Instruction Manual. Mini Hotplate Mini Stirrer Mini Hotplate Stirrer Instruction Manual Mini Hotplate Mini Stirrer Mini Hotplate Stirrer Table of Contents Package Contents............ 1 Warranty............ 1 Installation............ 2 Maintenance & Servicing............

More information

Instruction Manual Mini Hotplate Mini Stirrer Mini Hotplate-Stirrer Mini Auto Stirrer Mini Fixed Temperature Hotplate

Instruction Manual Mini Hotplate Mini Stirrer Mini Hotplate-Stirrer Mini Auto Stirrer Mini Fixed Temperature Hotplate Instruction Manual Mini Hotplate Mini Stirrer Mini Hotplate-Stirrer Mini Auto Stirrer Mini Fixed Temperature Hotplate Table of Contents Package Contents................ 1 Warranty................ 1 Installation................

More information

VSD AND SS DRIVING ATEX MOTORS February 2014

VSD AND SS DRIVING ATEX MOTORS February 2014 VSD AND SS DRIVING ATEX MOTORS February 2014 1 Introduction to ATEX 2 ATEX motor designation 3 VSD Sample Solutions 4 SS descriptions Introduction to ATEX EU territory define the use of electrical equipment

More information

Manufacturers of Explosion Proof, Corrosion Resistant and Severe Duty HVAC/R Systems, and Pressurization Equipment.

Manufacturers of Explosion Proof, Corrosion Resistant and Severe Duty HVAC/R Systems, and Pressurization Equipment. Manufacturers of Explosion Proof, Corrosion Resistant and Severe Duty HVAC/R Systems, and Pressurization Equipment. COPYRIGHT 2011 Safe Air Technology LLC. All Rights Reserved Severe Duty Design for: Safe

More information

Flammable and Combustible Liquids: Storage and Handling

Flammable and Combustible Liquids: Storage and Handling Safety services Software Training Other articles Flammable and Combustible Liquids: Storage and Handling By W. Jon Wallace, CSP, MBA Flammable and combustible liquids are present in nearly every workplace.

More information

Explosion Proof Speaker, Ringer & Speaker/Ringer

Explosion Proof Speaker, Ringer & Speaker/Ringer Explosion Proof Speaker, Ringer & Speaker/Ringer Models SR40 and SR60 Installation & Operation P004562 Rev. G 150831 8/31/2015 11:06 AM Ph: 403.258.3100 \ email:info@guardiantelecom.com \ www.guardiantelecom.com

More information

1. GENERAL TECHNICAL INFORMATION

1. GENERAL TECHNICAL INFORMATION 1. GENERAL TECHNICAL INFORMATION 1.1 EXPLOSIVE ATMOSPHERES: Every time that dangerous quantities and concentration of flammable gas, vapors mixture or dust clouds exists, risk of explosions may arise.

More information

ESD3000IR ESD3000IR. Infrared Gas Detector

ESD3000IR ESD3000IR. Infrared Gas Detector ESD3000IR ESD3000IR Infrared Gas Detector Infrared gas sensor Ex-proof certificate Exd ⅡC T6 Gb Dust Ex-proof certificate Ex td A21 IP66 T80 Site LCD display HART communication Replaceable sensor design

More information

Working safely with flammable liquids

Working safely with flammable liquids Flammable Liquids Fire hazards are associated with vapors from the flammable liquid. In order for a fire to occur, the following conditions must be met: Concentration of the vapor must be between the upper

More information

Explosion Proof Speaker, Ringer & Speaker/Ringer

Explosion Proof Speaker, Ringer & Speaker/Ringer Explosion Proof Speaker, Ringer & Speaker/Ringer Models SR40 and SR60 Installation & Operation P004562 Rev. H 180430 4/30/2018 12:24 PM Ph: 403.258.3100 \ email:info@guardiantelecom.com \ www.guardiantelecom.com

More information

Flammable and Combustible Liquids Checklist

Flammable and Combustible Liquids Checklist Flammable and Combustible Liquids Checklist This checklist covers the storage and use of flammable or combustible liquids in drums or other containers not exceeding 60 gallons individual capacity. Dispensing

More information

ESD3000 ESD200 Combustible / Toxic Gas Detector

ESD3000 ESD200 Combustible / Toxic Gas Detector ESD3000 ESD200 Combustible / Toxic Gas Detector Combustible and toxic gas leakage inspection instrument in industrial application Ex-proof certificate Exd ⅡC T6 Gb/Ex d ib ⅡC T6 Gb Dust Ex-proof certificate

More information

ESD500. ESD500 Combustible / Toxic Gas Detector

ESD500. ESD500 Combustible / Toxic Gas Detector ESD500 ESD500 Combustible / Toxic Gas Detector Combustible and toxic gas leakage inspection instrument in industrial application Ex-proof certificate Exd ⅡC T6 Gb/Ex d ib ⅡC T6 Gb Dust Ex-proof certificate

More information

Fire Alarm System Accessories

Fire Alarm System Accessories UL, ULC Approved* Fire Alarm System Accessories Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer isolated barrier

More information

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring] ULTIMA XIR ULTIMA X 3 ULTIMA XE ULTIMA X Series [ State-of-the-Art Gas Monitoring] ULTIMA X Gas Monitors [ Providing a unique Range of Capabilities] ULTIMA X are state-of-the-art gas monitors for continuous

More information

Star Teck. Teck and Tray Cable Fittings. Table of Contents

Star Teck. Teck and Tray Cable Fittings. Table of Contents Table of Contents The Whole Family...A2 A3 Specifications... A4 A5 Hazardous Locations CEC Classifications... A6 A9 Hazardous Locations Class, Zone and Division Certifications... A10 Quick Reference...A11

More information

For technical questions, contact: Grace Engineered Products Inc./ 5001 Tremont Ave, Davenport, IA /

For technical questions, contact: Grace Engineered Products Inc./ 5001 Tremont Ave, Davenport, IA / For technical questions, contact: Grace Engineered Products Inc./ 5001 Tremont Ave, Davenport, IA 52807 / 800.280.9517 563.386.9639 (Fax) INSTALLATION AND OPERATING INSTRUCTIONS R-3W2 UL APPROVED FOR:

More information

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features. Features To measure and take control of indoor air quality Three noses in same unit Air Quality (VOC), Humidity (rh) and Temperature (T) Selectable outputs 0-10 Vdc, 4-20 ma or 0-5 Vdc via jumpers on pcb

More information

Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global

Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global 597 Flameproof Type Light Curtain Type 4 General terms and conditions... F-3 Related Information guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P.1595 PHOTO PHOTO Certified

More information

Explosion protection Marijan Gorše, dipl. ing.

Explosion protection Marijan Gorše, dipl. ing. Explosion protection Marijan Gorše, dipl. ing. 1/18 Flammable Gas Atmosphere We Can Control Them Explosion hazards mostly arise from flammable gases and vapours. Instead of avoiding their ignition by explosion

More information

Fire Alarm System Accessories

Fire Alarm System Accessories Approved by APPROVED Fire Alarm System Accessories FM Approved* Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer

More information

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62.

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62. 637 PHOTO PHOTO Flameproof Type Curtain Type 4 General terms and conditions... F-7 Related Information Glossary of terms... P.1455~ Sensor selection guide... P.497~ General precautions... P.1458~ Conforming

More information

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV Instruction Manual Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV2 9296050000 About This Manual This manual is designed to assist you in optimal usage of your

More information

Hazardous area descriptions

Hazardous area descriptions Hazardous area descriptions National Electrical Code (NEC) 500 Traditional standards used in North America. Example: Class I, Div 1, Group B, C, D, T4 Permitted Class Permitted Division Permitted Group

More information

WATER BATH BM100 BM200

WATER BATH BM100 BM200 No.AC5-9708-12-BM WATER BATH BM100 BM200 First Edition Thank you for your Yamato Scientific BM series Water Bath purchase. For proper use of this unit, please read the instruction manual and warranty thoroughly

More information

Explosion-Proof and Fan-Forced Unit Heaters. Our products do more in a wide range of applications. Expect More.

Explosion-Proof and Fan-Forced Unit Heaters. Our products do more in a wide range of applications. Expect More. Explosion-Proof and Fan-Forced Unit Heaters Our products do more in a wide range of applications. Expect More. Introduction/Table of Contents Indeeco offers commercial and industrial electric heating and

More information

StableTemp Hotplates, Stirrers and Stirring Hotplates

StableTemp Hotplates, Stirrers and Stirring Hotplates StableTemp Hotplates, Stirrers and Stirring Hotplates OPERATION MANUAL AND PARTS LIST Hotplates: Catalog # Size Voltage Top Plate Material 03405-00 4x4 120 Ceramic 03405-05 4x4 240 Ceramic 03405-10 7x7

More information

Combustible Gas Detection and Control System

Combustible Gas Detection and Control System Combustible Gas Detection and Control System DESCRIPTION Gas monitor with built-in combustible gas sensor, wall-mounted, accepts inputs from remote devices such as other gas sensors, temperature or humidity

More information

Electric Explosion-Proof Heaters & Thermostats. Product Catalog

Electric Explosion-Proof Heaters & Thermostats. Product Catalog Electric Explosion-Proof Heaters & Thermostats Product Catalog Contents Norseman TM Electric Explosion-Proof Heaters & Thermostats... 4 Standard Features... 4 Durable Construction... 4 Simplified Wiring...

More information

Flameproof Type Light Curtain Type 4

Flameproof Type Light Curtain Type 4 545 PHOTO PHOTO Flameproof Type Curtain Type 4 Sensor selection guide...p.11~ / P.479~ General terms and conditions... P.1 SF4-AH... P.569 ~ Glossary of terms / General precautions... P.983 ~ / P.986 ~

More information

INSTALLATION AND OPERATING INSTRUCTIONS R-3F2-LXX

INSTALLATION AND OPERATING INSTRUCTIONS R-3F2-LXX INSTALLATION AND OPERATING INSTRUCTIONS R-3F2-LXX UL APPROVED FOR: CLASS I, DIVISION 2 HAZ LOC CAT III & IV www.pesd.com Part Number Description: The XX specifies the fiber-o cable length in inches. General

More information

Electric Explosion-Proof Heaters & Thermostats. Product Catalog

Electric Explosion-Proof Heaters & Thermostats. Product Catalog Electric Explosion-Proof Heaters & Thermostats Product Catalog Contents Norseman TM Electric Explosion-Proof Heaters & Thermostats... 4 Standard Features... 4 Durable Construction... 4 Simplified Wiring...

More information

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The entrepreneurial basis of the R. STAHL Technology Group follows a long tradition. The product range is aimed at specialised

More information

Thermo Scientific Flammable Material and Explosion-Proof Refrigerators and Freezers. Safe cold storage for Hazardous material

Thermo Scientific Flammable Material and Explosion-Proof Refrigerators and Freezers. Safe cold storage for Hazardous material Thermo Scientific Flammable Material and Explosion-Proof Refrigerators and Freezers Safe cold storage for Hazardous material Flammable Material Storage Thermo Scientific flammable material lab refrigerators,

More information

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS For a print friendly page click here INTRODUCTION Hazardous areas are those in which there exists a risk of explosion

More information

Vacuum Pumps America Inc. Dry Screw Vacuum Pump VSS Series

Vacuum Pumps America Inc. Dry Screw Vacuum Pump VSS Series Vacuum Pumps America Inc. Dry Screw Vacuum Pump VSS Series VPA-VSS60Ex VPA-VSS60Ex VPA-VSS100 Features of VSS Dry Screw Vacuum Pumps: Rugged and Robust design. Capable of handling all types of gases, vapors

More information

SBS-H2 Hydrogen Gas Detector Kit

SBS-H2 Hydrogen Gas Detector Kit SBS-H2 Hydrogen Gas Detector Kit For battery charging rooms and other areas where hydrogen gas may be present INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS Protects Life, Property and Profits Electrical

More information

INSTALLATION, PARTS, SERVICE & MAINTENANCE MANUAL FOR EPH-FH SERIES HEATER

INSTALLATION, PARTS, SERVICE & MAINTENANCE MANUAL FOR EPH-FH SERIES HEATER INSTALLATION, PARTS, SERVICE & MAINTENANCE MANUAL FOR EPH-FH SERIES HEATER Electric Air Heaters for Hazardous Locations Divisions 1 & 2 Class I Group C, D - Class II, Groups E, F & G Models covered by

More information

Relays for use in hazardous locations. Class I, Division 2 and ATEX

Relays for use in hazardous locations. Class I, Division 2 and ATEX Relays for use in hazardous locations Class I, Division 2 and ATEX Explosion protection in North America azardous (classified) locations, as defined in the National Electric Code (NEC), are locations where

More information

555 Hotplate 565 Magnetic Stirrer 575 Hotplate-Stirrer

555 Hotplate 565 Magnetic Stirrer 575 Hotplate-Stirrer 555 Hotplate 565 Magnetic Stirrer 575 Hotplate-Stirrer TABLE OF CONTENTS Package Contents........... 1 Controls........... 2 Installation........... 3 Maintenance & Servicing.......... 3 Temperature Probe...........

More information

Brasch Hazardous Location Unit Heaters

Brasch Hazardous Location Unit Heaters Brasch Hazardous Location Unit Heaters BHUH Features Designed for rugged industrial applications in hazardous locations where the possibility of explosion or fire exists due to the presence of certain

More information

Dräger PEX 3000 Flammable Gas Detection

Dräger PEX 3000 Flammable Gas Detection Dräger PEX 3000 Flammable Gas Detection The transmitter Dräger PEX 3000 detects flammable gases and vapors in concentrations below their Lower Explosion Limit Its DD-sensor provides a very long-term stable

More information

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases DESCRIPTION Gas measuring and monitoring controller based on stateof-the-art microtechnology with integrated sensor for continuous monitoring

More information

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified OPERATIONS MANUAL Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS-1001 Certified Contents 1. Safety 3 2. Introduction 7 3. Package Contents 7 4. Specifications 7 5. Features 8 6.

More information

MERIDIAN UNIVERSAL GAS DETECTOR

MERIDIAN UNIVERSAL GAS DETECTOR MERIDIAN UNIVERSAL GAS DETECTOR MERIDIAN UNIVERSAL GAS DETECTOR The term universal is frequently used in the industry to characterize gas detectors that address both toxic and combustible gases, but it

More information

Dräger Polytron SE Ex Fixed Gas Detector

Dräger Polytron SE Ex Fixed Gas Detector Dräger Polytron SE Ex Fixed Gas Detector The Dräger Polytron SE Ex... DD sensing heads are gas detectors for the continuous monitoring of flammable gases and vapors in the ambient air. The measurement

More information

Instruction Manual Analog Vortex Mixer with Fixed Cup Head

Instruction Manual Analog Vortex Mixer with Fixed Cup Head Instruction Manual Analog Vortex Mixer with Fixed Cup Head Table of Contents Package Contents............ 1 Warranty............ 1 Installation............ 2 Maintenance & Servicing............ 2 Environmental

More information

Implementation of ATEX Guidelines

Implementation of ATEX Guidelines Implementation of ATEX Guidelines Temperature and Climatic Test Chambers for Usage under Conditions Carrying a Risk of Fire and Explosion What are ATEX guidelines? Introduction Duties of the system user...

More information

Specifying Temperature Sensors for Hazardous Areas

Specifying Temperature Sensors for Hazardous Areas Specifying Temperature Sensors for Hazardous Areas The manufacture of petroleum products, paint, and many chemicals can lead to the release of flammable gases. When these gases accumulate in enclosed areas,

More information

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-8: ELECTRICAL EQUIPMENT ENCLOSURES AND HAZARDOUS LOCATIONS

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-8: ELECTRICAL EQUIPMENT ENCLOSURES AND HAZARDOUS LOCATIONS TSEWG TP-8: ELECTRICAL EQUIPMENT ENCLOSURES AND HAZARDOUS LOCATIONS ENCLOSURES. Select equipment enclosures to provide the following: To protect facility personnel from coming in contact with live parts.

More information

Cimarec Stirring Hot Plates

Cimarec Stirring Hot Plates Cimarec Stirring Hot Plates OPERATION MANUAL AND PARTS LIST Model # Top Plate Size Voltage SP131014 4x4 100 SP131015 4x4 120 SP131010-33 4x4 220-240 SP131324 7x7 100 SP131325 7x7 120 SP131320-33 7x7 220-240

More information

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM Key Features & Benefits: ATEX, UL and CSA Approvals Withstands EN/IEC 60079-0 impact test Enhanced H 2 S and silicone poison resistance 4P-90 CiTipeL Combustible Gas Sensor Part Number: PM143-000 Performance

More information

Guide for hazardous areas

Guide for hazardous areas Guide for hazardous areas 1 Hazardous areas definitions 2 Gas and dust s 3 Temperature classifications 4 Common flammable gases, vapours and dust types 5 Protection concepts ATEX and IECEx 6 Protection

More information

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety LD910 Combustible Gas Leak Detector Detects all Hydrocarbon and other Combustible Gases User Manual MSHA Approved Intrinsic Safety Made in U.S.A. LeakDetectors-LD910-UserManual.indd 1 INTRODUCTION The

More information

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS Hazardous Areas - EXPLOSIONPROOF SOLENOIDS SOME HISTORY The classification of hazardous areas into zones established the level of protection required for electrical equipment installed in explosive gas

More information

Sioux EN-Series. All-Electric Extra Heavy Duty Industrial Steam Cleaners and Pressure Washers

Sioux EN-Series. All-Electric Extra Heavy Duty Industrial Steam Cleaners and Pressure Washers Sioux EN-Series All-Electric Steam Cleaners and Pressure Washers Sioux EN-Series All-Electric Extra Heavy Duty Industrial Steam Cleaners and Pressure Washers Model EN-270-H4-3000-XP When Performance and

More information

Thank You for Attending Today s Webinar:

Thank You for Attending Today s Webinar: Detect, Measure, Analyze. Thank You for Attending Today s Webinar: Best Practices in Maintaining Gas Detection Systems Featured Speaker John Greivell VP Operations RAECO-LIC LLC johng@raeco.com Featured

More information

99 Washington Street Melrose, MA Phone Toll Free Visit us at

99 Washington Street Melrose, MA Phone Toll Free Visit us at 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Combustible Gas Leak Detector Instruction and Operation Manual Page 2 Detector

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET S p e c i f i c a t i o n WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700 D e t e c t o r C o n t r o l P a n e l Wall mounting 24V DC or 110/230vAC operation

More information

HOT PLATE OPERATION MANUAL AND PARTS LIST Series 64

HOT PLATE OPERATION MANUAL AND PARTS LIST Series 64 BARNSTEAD THERMOLYNE CORPORATION HOT PLATE OPERATION MANUAL AND PARTS LIST Series 64 MODELS HPA1910M HPA1910M-26 HPA1914B HPA1915B HPA1915B-13 LT64X2 7/6/98 1 Table of Contents Safety Information... 3

More information

Meridian. Universal Gas Detector. Description. Features. Minimal drift High specificity Digital ID Broader toxic gas detection

Meridian. Universal Gas Detector. Description. Features. Minimal drift High specificity Digital ID Broader toxic gas detection 3M TM Meridian Description Designed with safety and reliability in mind, the Meridian universal gas detector is suitable for use in SIL-2 and SIL-3-rated systems under the IEC 61508 standards, certified

More information

vwr.com. L a b o r a t o r y P u m p s + S y s t e m s

vwr.com. L a b o r a t o r y P u m p s + S y s t e m s 1.800.932.5000 vwr.com L a b o r a t o r y P u m p s + S y s t e m s Oil-free and corrosion resistant, KNF pumps and systems are ideal for a wide range of laboratory applications. 97014-790 26678-012 89220-172

More information

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

4P75 CiTipeL Combustible Gas Sensor Part Number: PM Product Datasheet 4P75 Document Purpose The purpose of this document is to present the performance specification of the 4P75 CiTipeL. This document should be used in conjunction with Operating Principles

More information

Organic Solvent Recovery Unit RT200. Instruction Manual. - First Edition -

Organic Solvent Recovery Unit RT200. Instruction Manual. - First Edition - Organic Solvent Recovery Unit Model RT200 Instruction Manual - First Edition - Thank you for purchasing "Organic Solvent Recovery Unit, RT200" of Yamato Scientific Co., Ltd. To use this unit properly,

More information

Description. Applications

Description. Applications CVEP PDS CVEP Convection for Hazardous Heater For Locations Hazardous Locations Convection Heater 1.8 to 9.0kW (T-2A) 280 C (536 F) 1.6 to 4.0kW (T-3A) 180 C (356 F) 1.8 to 9.0kW (T-2) 1.8 300 C to 9.0kW

More information

MICROpeL 75 Combustible Gas Sensor Part Number: PM

MICROpeL 75 Combustible Gas Sensor Part Number: PM MICROpeL 75 Combustible Gas Sensor Part Number: PM759-000 Key Features & Benefits: ATEX, UL and CSA Approvals Withstands EN/IEC 60079-0 impact test Enhanced H 2 S and silicone poison resistance Reduced

More information

StableTemp Digital Hotplates, Stirrers and Stirring Hotplates

StableTemp Digital Hotplates, Stirrers and Stirring Hotplates StableTemp Digital Hotplates, Stirrers and Stirring Hotplates OPERATION MANUAL AND PARTS LIST Hotplates: Catalog # Size Voltage Top Plate Material 03405-40 7x7 120 Ceramic 03405-45 7x7 230 Ceramic Stirring

More information

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR) Instruction Manual For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR) Corning Cat. No. 230V 230V Model No. Product Top Plate Size

More information

Model C Combustible Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

Model C Combustible Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park Model C12-17 Combustible Gas Transmitter Home Office European Office Analytical Technology, Inc. ATI (UK) Limited 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park Collegeville, PA 19426 Delph New

More information

INSTRUCTION MANUAL. stirring hotplate. VMS-C7 advanced series. Brand :

INSTRUCTION MANUAL. stirring hotplate. VMS-C7 advanced series. Brand : INSTRUCTION MANUAL stirring hotplate Model : Brand : VMS-C7 advanced series Instruction Manual Hotplates, Stirrers, Hotplate-Stirrers Standard Series Advanced Series TABLE OF CONTENTS Package Contents...............

More information

Isotemp Hotplates, Stirrers and Stirring Hotplates

Isotemp Hotplates, Stirrers and Stirring Hotplates Isotemp Hotplates, Stirrers and Stirring Hotplates OPERTION MNUL ND PRTS LIST LT892X 2/28/09 Catalog # Type Top Plate Size and Material Voltage 0000H Hotplate 0x0 Ceramic 20 0000S Stirrer 0x0 Ceramic 20

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS I. GENERAL Heatrex Explosion-proof Pipe Thread Mounted Immersion Heaters are CSA approved

More information

SUPER-NUOVA Digital Plates

SUPER-NUOVA Digital Plates SUPER-NUOVA Digital Plates OPERATION MANUAL AND PARTS LIST Model # Voltage Description HP133425 120 7X7 Hot Plate HP133420-33 220-240 7X7 Hot Plate HP133424 100 7X7 Hot Plate SP133525 120 7X7 Stirring

More information

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or

More information

Explosion-protected actuator Page 259 of 292

Explosion-protected actuator Page 259 of 292 Explosion-protected actuator Page 259 of 292 9.5 Explosion-protected actuator 9.5.1. What is an explosion? A flammable substance and oxygen, in a certain mixture, must be available to set off an explosion.

More information

NGD8800 USER S MANUAL

NGD8800 USER S MANUAL NGD8800 USER S MANUAL COMBUSTIBLE GAS DETECTOR Please read this manual carefully and thoroughly before using this product. CONTENT Page 1. GENERAL INFORMATION ------------------ 2 2. FEATURES -----------------------------------------

More information

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS GENERAL INDEECO Industrial Control Panels are designed to provide years of trouble free operation if properly

More information

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS INDEECO Circulation Heaters are designed to provide years of trouble free operation if properly installed and maintained. Please read and follow these instructions for installing and maintaining the heater.

More information

III. 99 Washington Street Melrose, MA Phone Toll Free Visit us at OPERATING INSTRUCTIONS

III. 99 Washington Street Melrose, MA Phone Toll Free Visit us at   OPERATING INSTRUCTIONS English OPERATING INSTRUCTIONS III COMBUSTIBLE GAS LEAK DETECTOR MODEL# 55975 99 Washington Street Melrose, MA 076 Phone 78-665-00 Toll Free -800-57-8 Visit us at www.testequipmentdepot.com PRODUCT OVERVIEW

More information

ATEX Safety Switches. More than safety.

ATEX Safety Switches. More than safety. ATEX Safety Switches More than safety. AUDIN - 8, avenue de la malle - 5370 Saint Brice Courcelles Tel : 03.6.0.0. - Fax : 03.6.0.8.0 - Web : http: www.audin.fr - Email : info@audin.fr ATEX products from

More information

INSTALLATION, PARTS, SERVICE & MAINTENANCE MANUAL FOR HLA SERIES HEATER

INSTALLATION, PARTS, SERVICE & MAINTENANCE MANUAL FOR HLA SERIES HEATER INSTALLATION, PARTS, SERVICE & MAINTENANCE MANUAL FOR HLA SERIES HEATER Electric Air Heaters for Hazardous Locations Divisions 1 & 2 Class I Group C, D - Class II, Groups E, F & G Models covered by this

More information

Overview of Hazardous Locations as They Relate to Solenoid Valves

Overview of Hazardous Locations as They Relate to Solenoid Valves Overview of Hazardous Locations as They Relate to Solenoid Valves Defined: Hazardous Location - "where fire or explosion hazards may exist due to flammable gases or vapors, flammable liquids, combustible

More information

and storage tanks. CO and NOx detection from diesel engine emissions Hospitality Hotels and restaurants LPG detection in commercial kitchens

and storage tanks. CO and NOx detection from diesel engine emissions Hospitality Hotels and restaurants LPG detection in commercial kitchens Scott Meridian Fixed Gas Detector This section introduces the Meridian Universal Fixed Gas Detector from Scott Safety, a Tyco International company and a world leader in the design and manufacture of industrial

More information

Hazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool

Hazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool Hazardous Area Classification in Oil & Gas Industry A Fire Prevention Tool SFPE ENGINEERING TECHNOLOGY CONFERENCE Oct 4, 2010 New Orleans, LA 1 Overview Oil and gas plants handle flammable materials 2

More information

Flammable Liquid Storage

Flammable Liquid Storage Published on UC Davis Safety Services (https://safetyservices.ucdavis.edu) Flammable Liquid Storage SafetyNet #: 523 Properties, Classification, Quantities, Cabinets, Containers and Refrigerators A. Summary

More information

VACUUM OVEN. Model: VPX9-2. Installation and Operation Manual

VACUUM OVEN. Model: VPX9-2. Installation and Operation Manual VACUUM OVEN Model: VPX9-2 Installation and Operation Manual Sheldon Manufacturing, Inc. P.O. Box 627, 300 N 26 th Avenue, Cornelius, Oregon 97113 EMAIL: tech @ Shellab.com; www.shellab.com 1-800-322-4897

More information

INSTRUCTION MANUAL. Stirring hotplate (with probe and stand) Brand : (Dragon laboratory)

INSTRUCTION MANUAL. Stirring hotplate (with probe and stand) Brand : (Dragon laboratory) INSTRUCTION MANUAL Stirring hotplate (with probe and stand) Model : Brand : MS-H280-pro (Dragon laboratory) User Manual MS-H280-Pro MS-PA BlueSpin LED Digital Hotplate Magnetic Stirrer BlueSpin LED Digital

More information

Professional Series. Instruction Manual Hotplates, Stirrers, Hotplate-Stirrers

Professional Series. Instruction Manual Hotplates, Stirrers, Hotplate-Stirrers Professional Series Instruction Manual Hotplates, Stirrers, Hotplate-Stirrers TABLE OF CONTENTS Package Contents............... 1 Warranty............... 1 Installation............... 2 Maintenance & Servicing...............

More information

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector SENSIT HXG-2 Instruction Manual For use with combustible gases Gas Leak Detector CLASSIFIED 7WA6 Approved UL913, For Class 1, Division 1, Groups C & D hazardous locations when used with alkaline batteries.

More information

LFL Monitoring. MEGTEC Systems

LFL Monitoring. MEGTEC Systems LFL Monitoring MEGTEC Systems Flammability For each volatile flammable substance there is a concentration in air (usually expressed as % of volume, known as Lower Flammable Limit LFL). Below LFL concentration

More information

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE 5000W Ceiling/Wall Mounted Garage Heater OWNER S MANUAL Model: PH-950N IMPORTANT INSTRUCTIONS READ & SAVE PET OWNERS WARNING: The health of some small pets including birds are extremely sensitive to the

More information

Magnetic Stirring Systems with Heat

Magnetic Stirring Systems with Heat Sharing your passion for making jewelry. Products. Service. Know-how. Magnetic Stirring Systems with Heat 335-212 Digital Ceramic Magnetic Stirring System with Heated Stand 335-211 Ceramic Magnetic Stirring

More information

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater Toll-Free: 1-800-462-4983 Hazardous Location Fan Forced Unit Heater 3-25KW for Class I, Group C & D, Division 1 & 2 and Class II, Groups E, F & G, Divisions 1 & 2. Designed for rugged industrial applications

More information

Model 950-ASH Arson Scanner Hydrocarbons and Accelerants Detector Operation and Maintenance

Model 950-ASH Arson Scanner Hydrocarbons and Accelerants Detector Operation and Maintenance Model 950-ASH Arson Scanner Hydrocarbons and Accelerants Detector Operation and Maintenance www.arsondetection.com M950-ASHTM1218 December 2018 Model 950-ASH Table of Contents Cover 1 Table of Contents

More information