Caleffi Hydronic Solutions Contact: Rex Gillespie, Director of Marketing Phone: (414)

Size: px
Start display at page:

Download "Caleffi Hydronic Solutions Contact: Rex Gillespie, Director of Marketing Phone: (414)"

Transcription

1 Caleffi North America, Inc W. Milwaukee Road Milwaukee, WI T: F: LITERATURE RELEASE Caleffi Hydronic Solutions June 10, 2010 Contact: Rex Gillespie, Director of Marketing Phone: (414) idronics Edition 6 Addendum Solar Thermal Combisystems Since the original publication of idronics Edition 6, methods have been developed that improve the performance of Caleffi DISCAL Air Separators when used in drainback combisystems. These changes increase the pressure differential across the venting mechanism with the separator. They also capture ejected by the separator mechanism and return it to the at the top of the storage tank, thus helping maintain a more consistent pressurization within the system. All revised drawings show an return from the outlet of the DISCAL Air Separator to a fitting at the top of the storage tank. Caleffi has adapter fittings available to transition from the outlet threads of the DISCAL Air Separators (Model 551) to ¼-inch NPT threads. The return tubing could be ¼-inch copper or other tubing suitable for the temperature and pressure ratings of the system. The drawings shown on the pages that follow replace those shown in the original schematics in idronics Edition 6. If you have a printed copy of this edition, print this document (in color if possible), cut out each schematic and tape it in place over the original drawing. idronics Edition 6, Rev 1 is available for download on our website and includes all modifications. The following figures in idronics Edition 6 have been modified: 5-9, 5-10, 5-13, 5-14, 5-15 CALEFFI Creating innovative, superior performance products that help customers live comfortably and economically, while softening their impact on the environment. # # #

2 Figure 5-9 revised: (idronics #6 page 31) All solar circuit piping sloped minimum 1/4" per ft. pressure! control valve time! delay! recirculation return A AB B 3-way! diverter! valve 3-way! motorized! mixing! valve pressureregulated end switch leads from actuators space-heating circuits! (highly zoned) end switch leads thermostat closely spaced tees manifold valve actuator DHW coil differential! controller

3 Figure 5-10 revised: (idronics #6 page 32) All solar circuit piping sloped minimum 1/4" per ft. anti-condensation! mixing valve boiler! conventional boiler! (requires protection! from flue gas condensation) room! thermostat time! delay! DHW coil A B AB return! diverter valve! reset! controller (C1) zone! s heating! load stor. 3-way! motorized! distribution! mixing valve! (reset control) anti-scald! tempering! valve differential! controller

4 Figure 5-13 revised: (idronics #6 page 35) thermo radiator valves! on each return! flow! switch stainless steel! brazed plate! heat exchanger

5 Figure 5-14 revised: (idronics #6 page 36) thermo radiator valves! on each return! flow! switch stainless steel! brazed plate! heat exchanger! w/ check flow! switch stainless steel! brazed plate! heat exchanger Domestic supplied by solar from storage tank

6 Figure 5-15 revised: (idronics #6 page 37) thermo radiator valves! on each return! Space heating supplied by solar from storage) thermo radiator valves! on each return! Space heating supplied by boiler (storage tank serves as buffer)

Outdoor Reset Control Theory FULL versus PARTIAL reset

Outdoor Reset Control Theory FULL versus PARTIAL reset Outdoor Reset Control Theory FULL versus PARTIAL reset Conventional boilers must be protected against sustained operation at low temperatures. If not, they will be damaged by sustained flue gas condensation.

More information

Dear Hydronic Professional, Dear Hydronic Professional,

Dear Hydronic Professional, Dear Hydronic Professional, Caleffi Caleffi North North America, America, Inc. Inc. 9850 3883 South W. Milwaukee 54 th Street Rd Franklin, Milwaukee, WI 53132 Wisconsin 53208 T: 414.421.1000 414.238.2360 F: F: 414.421.2878 414.238.2366

More information

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve VENT APPENDIX A: PIPING SYMBOL LEGEND GENERIC COMPONENTS CALEFFI COMPONENTS circulator circulator w/ ThermoBloc union circulator w/ swing check spring loaded balancing balancing w/ gate check globe s purging

More information

Installation & Operation Manual Models: TSU

Installation & Operation Manual Models: TSU TSU-I-O Rev A Installation & Operation Manual Models: TSU 150-940 CAUTION: This appliance is not intended for potable water. This manual must only be used by a qualified heating installer / service technician.

More information

hydronics WHAT S WRONG WITH THIS SCHEMATIC?

hydronics WHAT S WRONG WITH THIS SCHEMATIC? BY JOHN SIEGENTHALER WHAT S WRONG WITH THIS SCHEMATIC? In the September/October 2005 issue of HPAC Magazine, methods to draw hydronic piping schematics were discussed. These drawings are an efficient way

More information

PART 5: HVAC & DHW SYSTEMS

PART 5: HVAC & DHW SYSTEMS PART 5: HVAC & DHW SYSTEMS Building Science Review Building Science Review: HVAC & DHW Systems This document will help you: Correctly answer all parts of the HVAC Systems section in the Home Energy Score

More information

Utica Boilers MAC Submittal

Utica Boilers MAC Submittal Utica Boilers MAC-150 - Submittal Engineer: Project Name: Project Location: Contractor: APPLICATION: Modulating Gas fired Combi boiler for indoor installation. Approved for closet or alcove installations.

More information

"Best Practices in Modern Hydronic Heating - THE DETAILS

Best Practices in Modern Hydronic Heating - THE DETAILS "Best Practices in Modern Hydronic Heating - THE DETAILS 190 supply water temperature (ºF) 170 150 130 110 90 fin-tube convector (RR=1.38) panel radiator (RR=1.0) thin slab rad. floor (RR=0.69) slab r

More information

Heating Installation Guide published by

Heating Installation Guide published by Heating Installation Guide published by MrPEX Systems 2613 87th Court W. Northfield, MN 55057 800-716-3406 mrpexsystems.com mrpex@mrpexsystems.com 2014 MrPEX Systems All rights reserved Printed September

More information

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers MADE IN AMERICA NOW WITH AUTO SET POINT AND OUTDOOR RESET INCLUDED! Meets Department of Energy s 01 Energy Saving Requirements! THE COMPACT MINI-THERM

More information

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA Thermostatic mixing valves with replaceable cartridge for centralized systems 3, 3 series CCREDITED ISO 9 FM ISO 9 No. 3 /3 N Replaces / N Function The thermostatic mixing valve is used in systems producing

More information

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

5231 Series.   Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341 NA31 www.caleffi.com Low Lead High Flow Thermostatic Mixing Valves Copyright 1 Caleffi Installation, commissioning and service instructions Function 531 Series ASSE 17 model 531 series high flow thermostatic

More information

Hydronic Mechanical Panels

Hydronic Mechanical Panels Hydronic Assemblies Inc. 56 Horse Hill Rd Concord NH 2015-2016 Hydronic Mechanical Panels Contact 4805 Main St. Waitsfield, Vermont 05673 Phone : 802-583-5500 WWW.Houseneeds.com Hydronic Assemblies Inc.

More information

Eco ULTRA - Heat Pump Buffer Tanks - Arctic Heat Pumps

Eco ULTRA - Heat Pump Buffer Tanks - Arctic Heat Pumps (/) Eco ULTRA - Heat Pump Buffer Tanks - Arctic Heat Pumps The perfect combination for any heat pump or geothermal hydronic heating system. Eco Ultra is the only buffer storage tank that is also a fully

More information

Pivot Stove Hydronic Installation Guide

Pivot Stove Hydronic Installation Guide Pivot Stove Hydronic Installation Guide Install Location When installing the header tank - install directly above the appliance. There needs to be a continual rise between the appliance and the header

More information

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers NOW WITH AUTO SET POINT AND OUTDOOR RESET INCLUDED! THE COMPACT MINI-THERM FOR SUPERB HOME HEATING COMFORT LAARS MINI-THERM gas-fired residential

More information

Thermostatic mixing valves with replaceable cartridge for centralized systems

Thermostatic mixing valves with replaceable cartridge for centralized systems Thermostatic mixing valves with replaceable cartridge for centralized systems series REGISTERED BS EN ISO 9: Cert. n FM UNI EN ISO 9: Cert. n / N Replaces /9 N Function The thermostatic mixing valve is

More information

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS LCB-I-O Rev B MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS Models: KB 81-286, KBXL 400-801, WB 51-211, and WH 55-399 IMG00116 WARNING This manual must only be used by a qualified heating installer

More information

The electrical wattage needed by the circulator is:

The electrical wattage needed by the circulator is: The electrical wattage needed by the circulator is: w e = 0.4344 f P n w/w A current-generation wet-rotor circulator has a maximum wire-towater efficiency in the range of 25 percent. If we put the data

More information

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS INDEX Ed. 20150422 GENERAL INFORMATION... 2 Before installing... 2 Materials and PED (97/23/CE) Standards... 3 SKID-TYPE DISTRICT HEATING

More information

281 Series. ThermoBloc boiler protection recirculation and distribution unit. Installation, commissioning and servicing instructions

281 Series. ThermoBloc boiler protection recirculation and distribution unit.   Installation, commissioning and servicing instructions www.caleffi.com NA1094.01 ThermoBloc boiler protection recirculation and distribution unit Copyright 013 Caleffi Installation, commissioning and servicing instructions 81 Series Function The ThermoBloc

More information

2019 PLUMBING AND HYDRONICS CATALOG

2019 PLUMBING AND HYDRONICS CATALOG 2019 PLUMBING AND HYDRONICS CATALOG COMPANY INFORMATION 1 HYDRAULIC SEPARATORS 2 AIR AND DIRT SEPARATORS AND AIR VENTS 3 THERMOSTATIC RADIATOR VALVES 4 ZONE VALVES AND ZONE CONTROLS 5 DISTRIBUTION MANIFOLDS

More information

ERGOMAX 7 INSTALLATION

ERGOMAX 7 INSTALLATION ERGOMAX 7 INSTALLATION INSTALLATION MUST CONFORM TO LOCAL CODES 1. WITH HYDRONIC BOILERS All ERGOMAX 7 units must be installed vertically. Adjustable feet for levelling are provided. PRESSURE RELIEF VALVE:

More information

Thermostatic mixing valves with interchangeable cartridges

Thermostatic mixing valves with interchangeable cartridges www.caleffi.com R37. Thermostatic mixing valves with interchangeable cartridges Installation, commissioning and servicing instructions 3 Series Function The thermostatic mixing valve is used in systems

More information

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe Copyright 206 Caleffi NA0322.02 www.caleffi.com NA5453 Series Installation, commissioning and servicing instructions Function

More information

Installation and Servicing Instructions. Alpha FlowSmart

Installation and Servicing Instructions. Alpha FlowSmart Installation and Servicing Instructions Alpha FlowSmart Hot Water System incorporating an Alpha InTec 30/40GS Condensing Combination Boiler with Integrated Flue Gas Heat Recovery Device and wall mounted

More information

InDEX. A Technical Journal from Caleffi Hydronic Solutions

InDEX. A Technical Journal from Caleffi Hydronic Solutions Caleffi Caleffi North North America, America, Inc. Inc. 9850 3883 South W. Milwaukee 54 th Street Rd Franklin, Milwaukee, WI 53132 Wisconsin 53208 T: 414.421.1000 414.238.2360 F: F: 414.421.2878 414.238.2366

More information

Installation, Operating and Service Instructions for use by heating contractor. VITOCELL r 300-W CAUTION IMPORTANT

Installation, Operating and Service Instructions for use by heating contractor. VITOCELL r 300-W CAUTION IMPORTANT Installation, Operating and Service Instructions for use by heating contractor Vitocell 300-W, EVIA Indirect-fired domestic hot water storage tank 42 USG (160 L) capacity VITOCELL r 300-W CAUTION The heat

More information

Application Guide. Vitodens 100-W B1HA/B1KA Residential Boiler

Application Guide. Vitodens 100-W B1HA/B1KA Residential Boiler Application Guide Vitodens 100-W B1HA/B1KA Residential Boiler APPLICATION GUIDE The application examples contained in this document serve as a guideline only. These are not engineered drawings and are

More information

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS LCB-I-O Rev D MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS Models: KB 81-286, KBXL 400-801, WB 51-211, FTX 400-850 and WH 55-399 WARNING This manual must only be used by a qualified heating installer

More information

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

5231 Series.  Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341. NA3. www.caleffi.com Low Lead High Flow Thermostatic Mixing Valves Copyright 5 Caleffi Installation, commissioning and service instructions Function 53 Series ASSE 7 model 53 series high fl ow thermostatic

More information

NCB-E Combi-boilers. The first high efficiency condensing combi boilers that can do it all... for larger homes

NCB-E Combi-boilers. The first high efficiency condensing combi boilers that can do it all... for larger homes The Leader in Condensing Technology NCB-E Combi-boilers The first high efficiency condensing combi boilers that can do it all... for larger homes New NaviLink Wi-Fi remote control system... Available as

More information

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB 4 RESET ON DHW CH FAULT SATK wall-mounted heat interface unit Fitted for connection to DHW storage SATK4 series ACCREDITED CALEFFI 6/4 GB ISO 9 FM 64 ISO 9 No. The latest generation of heat interface units

More information

INDIRECT FIRED WATER HEATERS

INDIRECT FIRED WATER HEATERS H E A T T R A N S F E R P R O D U C T S INDIRECT FIRED WATER HEATERS RESIDENTIAL COMMERCIAL Heat Transfer Products, Inc., reserves the right to make product changes or updates without notice. Heat Transfer

More information

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring Page 1 of 8 IMAGINATION SOLAR LTD Installation Guide B1 Planning the Plumbing and Wiring Unit 4 Montpelier Central, Station Road Bristol BS6 5EE t: 0117 942 6668 f: 0117 942 8998 e: enquiries@imaginationsolar.com

More information

Installation, commissioning and servicing instructions

Installation, commissioning and servicing instructions NA10322.01 www.caleffi.com DIRTMAG dirt separator Copyright 2015 Caleffi NA5453 Series Installation, commissioning and servicing instructions Function In heating and chilled water systems, the circulation

More information

Thermostatic Radiator Valves (Caleffi)

Thermostatic Radiator Valves (Caleffi) 02/09/16 B46 Thermostatic Radiator Valves (Caleffi) Thermostatic Control Heads Thermostatic control head fits radiator valves Set point locking mechanism Range stop adjustment Built-in sensor with liquid-filled

More information

Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS

Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS Comprehensive technology, energy-saving performance, plus compact professional design make HydroShark s modular panel

More information

OG-300 Internal Coil Solar Hot Water Systems Schematics and Parts Lists

OG-300 Internal Coil Solar Hot Water Systems Schematics and Parts Lists OG-00 Internal Coil Solar Hot Water Systems Schematics and Parts Lists (Revision. - July 0) IMPORTANT INFORMATION Diagrams are conceptual only and not to scale.!final system design must adhere to all relevant

More information

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

521 Series.  MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions MixCal adjustable three-way thermostatic mixing valve 37. www.caleffi.com Copyright 15 Caleffi 51 Series Installation, commissioning and service instructions Function The Caleffi MixCal three-way thermostatic

More information

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package

More information

Dunkirk H 2 O. Innovative. Efficient. Dependable. Dunkirk.

Dunkirk H 2 O. Innovative. Efficient. Dependable. Dunkirk. Innovative. Efficient. Dependable. Dunkirk. Dunkirk H 2 O - Stainless Steel Single & Dual Indirect Water Heaters - Storage Tanks - Hydronic Buffer Tanks Introducing the NEW Dunkirk H 2 O Series... A complete

More information

Hydraulic Separation Moving Beyond Priamry / Secondary Piping...

Hydraulic Separation Moving Beyond Priamry / Secondary Piping... Hydraulic Separation Moving Beyond Priamry / Secondary Piping... load! #1 load! #2 load! #3 primary! circulator presented by: John Siegenthaler, P.E. Appropriate Designs Holland Patent, NY www.hydronicpros.com

More information

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

HEAT INTERFACE UNITS (Sanitary Hot Water Only) HEAT INTERFACE UNITS (Sanitary Hot Water Only) T-FAST i20 (Sanitary Hot Water Only) 20 The T-Fast i20 is an instantaneous domestic hot water production module that produces a flow rate of 20L per/min at

More information

NPE-A and NPE-S Condensing Tankless Water Heaters

NPE-A and NPE-S Condensing Tankless Water Heaters The Leader in Condensing Technology NPE-A and NPE-S Condensing Tankless Water Heaters Navien makes it easy to go tankless in residential and commercial applications. New NaviLink Wi-Fi remote control system...now

More information

Seradens Super Seradens Super Plus

Seradens Super Seradens Super Plus Premix Full Condensing Combi Boilers Seradens Super Seradens Super Plus 20-28 - 36 kw THE FIRST CONDENSING TECHNOLOGY BOTH IN HEATING AND DOMESTIC HOT WATER IN TURKEY Smaller, more elegant and efficient

More information

Installation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T

Installation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T www.caleffi.com 37. MixCal adjustable three-way thermostatic mixing valve Copyright Caleffi Installation, commissioning and servicing instructions Series Function The Caleffi MixCal three-way thermostatic

More information

Bristol s Six Principles for Good Solar Hydronic Design SLASH-D: Software for Solar Heating Design

Bristol s Six Principles for Good Solar Hydronic Design SLASH-D: Software for Solar Heating Design This is the unedited version of the article that appeared in Plumbing Engineer and Plumbing and Hydronics Contractor in May 2013. It is the 59 th article by Bristol Stickney, Chief Technical Officer of

More information

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F 34-200 SERIES HYDRONIC TEMPERING VALVES The Apollo Model TV (34-200 Series) thermostatic mixing valve provides non-asse extension of water heater capacity and hot water temperature control in hydronic

More information

DOWNLOAD OR READ : DOMESTIC CENTRAL HEATING WIRING SYSTEMS AND CONTROLS SECOND EDITION PDF EBOOK EPUB MOBI

DOWNLOAD OR READ : DOMESTIC CENTRAL HEATING WIRING SYSTEMS AND CONTROLS SECOND EDITION PDF EBOOK EPUB MOBI DOWNLOAD OR READ : DOMESTIC CENTRAL HEATING WIRING SYSTEMS AND CONTROLS SECOND EDITION PDF EBOOK EPUB MOBI Page 1 Page 2 domestic central heating wiring systems and controls second edition domestic central

More information

NPE-A and NPE-S Condensing Tankless Water Heaters

NPE-A and NPE-S Condensing Tankless Water Heaters The Leader in Condensing Technology NPE-A and NPE-S Condensing Tankless Water Heaters Navien makes it easy to go tankless in residential and commercial applications. New NaviLink Wi-Fi remote control system...now

More information

RA15/6T & TB Conversion Valve

RA15/6T & TB Conversion Valve Applications: continue on. This provides continuous flow, but inherent to series piping the supply water temperature will decrease as it flows through the system and when it mixes with return water from

More information

Hydronic Solutions for Low Energy Houses

Hydronic Solutions for Low Energy Houses Hydronic Solutions for Low Energy Houses February 8, 2018 Burlington, VT Sponsored by: panel radiator TRV APPLIANCE! for space heating! and DHW presented by: John Siegenthaler, P.E. Appropriate Designs

More information

Crown Boiler Company

Crown Boiler Company Crown Boiler Company 1 Phantom Boiler System Combi Kit Instruction Manual I Product Description This kit adds the ability to generate DHW, as well as heat, ( combi capability) to select Phantom models

More information

Utica H 2 O. There Are Some Things You Can Always Depend On...

Utica H 2 O. There Are Some Things You Can Always Depend On... There Are Some Things You Can Always Depend On... Utica H 2 O - Stainless Steel Single & Dual Indirect Water Heaters - Storage Tanks - Hydronic Buffer Tanks Introducing the NEW UTICA H2O Series... A complete

More information

Automatic Temperature Controller (ATC)

Automatic Temperature Controller (ATC) NEW FROM APOLLO...THE FIRST MULTIPLE-FIXTURE HI-LO MIXING VALVE THAT MEETS ASSE 1017 AND THE NEW ASSE 1069 STANDARD Only Apollo offers fast delivery on the first water temperature mixing assembly to meet

More information

Models CHB/CCB APPLICATION GUIDE WALL MOUNTED GAS BOILER

Models CHB/CCB APPLICATION GUIDE WALL MOUNTED GAS BOILER Models CHB/CCB APPLICATION GUIDE WALL MOUNTED GAS BOILER This manual has been prepared for use with the appropriate Installation, Operation and Maintenance Manual. For use with CCB/CHB Boilers ONLY. Manufactured

More information

AQUAMATIC HOT WATER IS YOUR NEW WELLNESS. Instant producer of sanitary hot water

AQUAMATIC HOT WATER IS YOUR NEW WELLNESS. Instant producer of sanitary hot water AQUAMATIC HOT WATER IS YOUR NEW WELLNESS Instant producer of sanitary hot water Aquamatic All the water that you need at the temperature you desire the best AQUAMATIC is the new system for the production

More information

ProRadiant Controls, Valves and Actuators

ProRadiant Controls, Valves and Actuators 214 Controls, Valves and Actuators Stock Controls, Valves and Actuators BASIC HEATING CONTROL Features: Modulating mixing valve control Supply temperature high limit Seasonal pump activation Boiler activation

More information

Adjustable three-way thermostatic mixing valve... connections ½", ¾", 1" NPT male union and sweat union and ¾" press

Adjustable three-way thermostatic mixing valve... connections ½, ¾, 1 NPT male union and sweat union and ¾ press MixCal djustable three-way thermostatic mixing valve series CCRIT ISO 9 FM ISO 9 No. CLFFI / N Replaces / N Function The Caleffi MixCal series three-way thermostatic mixing valve is used in systems producing

More information

Installation & Operation Manual Models: SIT030, SIT040, SIT050, SIT065, SIT080, & SIT119

Installation & Operation Manual Models: SIT030, SIT040, SIT050, SIT065, SIT080, & SIT119 SIT-I-O Rev B Installation & Operation Manual Models: SIT030, SIT040, SIT050, SIT065, SIT080, & SIT119 WARNING This manual must only be used by a qualified heating installer / service technician. Read

More information

Mini-Combo id. Model MCH. Installation and Operation Instructions. Induced Draft Residential Gas-Fired Space/Water Heater

Mini-Combo id. Model MCH. Installation and Operation Instructions. Induced Draft Residential Gas-Fired Space/Water Heater Installation and Operation Instructions Document 2101B Installation and Operation Instructions for Mini-Combo id Model MCH Induced Draft esidential Gas-Fired Space/Water Heater Note: This document is to

More information

ARTESIAN 220 & 340 Instantaneous Indirect Water Heater By Dunkirk Boilers INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL

ARTESIAN 220 & 340 Instantaneous Indirect Water Heater By Dunkirk Boilers INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL ARTESIAN 220 & 340 Instantaneous Indirect Water Heater By Dunkirk Boilers INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL Manufacturer's Warning To reduce the possibility of injury due to scalding,

More information

LOW TEMPERATURE HYDRONIC HEATING FOR COLD CLIMATES TRAVIS SMITH PRESIDENT T AND T MOUNTAIN BUILDERS INC

LOW TEMPERATURE HYDRONIC HEATING FOR COLD CLIMATES TRAVIS SMITH PRESIDENT T AND T MOUNTAIN BUILDERS INC LOW TEMPERATURE HYDRONIC HEATING FOR COLD CLIMATES TRAVIS SMITH PRESIDENT T AND T MOUNTAIN BUILDERS INC COLD CLIMATES REFERRING SPECIFICALLY TO CLIMATES ZONES 6 & 7 HYDRONIC HEATING USING A FLUID TO TRANSFER

More information

Applications and Piping Strategies for Condensing Boilers - Introduction

Applications and Piping Strategies for Condensing Boilers - Introduction Applications and Piping Strategies for Condensing Boilers - Introduction Foil 2, 10/2015 Viessmann Manufacturing Applications and Piping Strategies for Condensing Boilers Webinar Objectives: 1. Control

More information

heat interface units A BOILER WITHOUT A FLAME

heat interface units A BOILER WITHOUT A FLAME A BOILER WITHOUT A FLAME heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment in the building.

More information

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25) ALKON CARGO ALKON CARGO model Max/min nominal output Heat input condensing Non-condensing η condensation at 30 part load 35 7,4 35,1 6,7 33,5 34,8 106,3 Efficiency class (directive 92/42) ALKON CARGO is

More information

NPE-A and NPE-S Condensing Tankless Water Heaters

NPE-A and NPE-S Condensing Tankless Water Heaters The Leader in Condensing Technology NPE-A and NPE-S Condensing Tankless Water Heaters Navien makes it easy to go tankless in residential and commercial applications. New NaviLink Wi-Fi remote control system...now

More information

TERMO Combi Cylinder TECHNICAL INFORMATION

TERMO Combi Cylinder TECHNICAL INFORMATION TECHNICAL INFORMATION TERMO Combi Cylinder Tank-In-Tank System using solar energy for hot water and heating support. For integration into the heating circuit as return flow booster or hydraulic compensator.

More information

EVALUATION SUBJECT: DIVISION: PLUMBING SECTION: FACILITY WATER DISTRIBUTION INSTRUMENTATION AND CONTROL FOR PLUMBING

EVALUATION SUBJECT: DIVISION: PLUMBING SECTION: FACILITY WATER DISTRIBUTION INSTRUMENTATION AND CONTROL FOR PLUMBING ICC-ES Report PMG-1360 Reissued 01/18/2018 This report is subject to renewal 10/2018 EVALUATION SUBJECT: LOW LEAD - PRESSURE REDUCING VALVE, TEMPERATURE ACTUATED MIXING VALVE, WATER TEMPERATURE LIMITING

More information

Water Heaters. Solar Applications

Water Heaters. Solar Applications Water Heaters Applications (Optional) 3-way diverting valve Pump Bypass for Cooling Water Bypass Return STONESTEEL is a registered trademark of Cemline Corporation CEMLINE CORPORATION P.O. BOX 55 CHESWICK,

More information

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job SERIES Commercial, Forced Draft, Hot Water or Steam Boiler Sizes from to,8 MBH output The right fit for any commercial job The Series is built to handle any installation - businesses, institutions, apartments,

More information

INSTALLATION INSTRUCTIONS Solamander Hydronic Energy Hub Controller SR313

INSTALLATION INSTRUCTIONS Solamander Hydronic Energy Hub Controller SR313 INSTALLATION INSTRUCTIONS Solamander Hydronic Energy Hub Controller SR313 Table of Contents 1 Important Safety Instructions... 3 2 System Description... 4 2.1 The System... 4 2.2 Energy Sources and Uses...

More information

ProLine XE Combi Boiler

ProLine XE Combi Boiler 100298581_2000552611_Rev A ProLine XE ProLine XE User Manual Models: 110-150 - 199 If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal

More information

NPE-A and NPE-S Condensing Tankless Water Heaters

NPE-A and NPE-S Condensing Tankless Water Heaters NPE-A and NPE-S Condensing Tankless Water Heaters Navien makes it easy to go tankless in residential and commercial applications. New NaviLink Wi-Fi remote control system...now available as an add-on accessory.

More information

Installation Instructions for use by heating contractor. VITOCELL r 100-B CAUTION IMPORTANT. Read and save these instructions for future reference.

Installation Instructions for use by heating contractor. VITOCELL r 100-B CAUTION IMPORTANT. Read and save these instructions for future reference. Installation Instructions for use by heating contractor Vitocell 100-B CVB/CVBB Series Enameled dual-coil, indirect-fired domestic hot water storage tank 79 USG and 119 USG (300 L and 450 L) capacity VITOCELL

More information

6 PIPING ARRANGEMENTS

6 PIPING ARRANGEMENTS 6 PIPING ARRANGEMENTS The design of a panel radiator based heating system involves selection of a piping system, pipe sizes, overall design temperature drop, required flow rates and desired type of system

More information

Water Piping and Pumps

Water Piping and Pumps Technical Development Program DISTRIBUTION SYSTEMS Water Piping and Pumps PRESENTED BY: Michael Ho carriertdp@gmail.com 424-262-2144 Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section

More information

Installation Instructions for use by heating contractor. VITOCELL r 100-V CAUTION IMPORTANT. Read and save these instructions for future reference.

Installation Instructions for use by heating contractor. VITOCELL r 100-V CAUTION IMPORTANT. Read and save these instructions for future reference. Installation Instructions for use by heating contractor Vitocell 100-V CVA/CVAA Series Enameled indirect-fired domestic hot water storage tank 42 USG to 119 USG (160 L to 450 L) capacity VITOCELL r 100-V

More information

High Capacity Instantaneous Steam Fired Water Heater

High Capacity Instantaneous Steam Fired Water Heater MODEL F High Capacity Instantaneous Steam Fired Water Heater Features Compact High Capacity Design Packaged System Water heater is factory assembled on an all welded steel mounting frame to save time and

More information

Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013

Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013 Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013 Calorifiers Heat Exchangers Pressurisation Units Sales Tel: 01457 835700 Sales Fax: 01457 832700 E-mail:

More information

TACOTHERM DUAL DECENTRALISED DOMESTIC HOT WATER TECHNOLOGY

TACOTHERM DUAL DECENTRALISED DOMESTIC HOT WATER TECHNOLOGY TACOTHERM DUAL DECENTRALISED DOMESTIC HOT WATER TECHNOLOGY WHAT DOES TACONOVA STAND FOR? Taconova Group AG is a well-established Swiss company with over years of experience in providing intelligent building

More information

User's Manual MODEL DPW-099 DPW-120. Rev1. Please use this product after reading this User's Manual for your safety.

User's Manual MODEL DPW-099 DPW-120. Rev1. Please use this product after reading this User's Manual for your safety. Rev1 User's Manual MODEL DPW-099 DPW-120 1. Safety Warnings 2 2. Names of Components 8 3. Proper Operation - Before Operation 10 - Cautions when in use 11 - Cautions to Prevent Freezing during the Winter

More information

Radiant Heating. Systems

Radiant Heating. Systems O p t i m i z i n g t h e P e r f o r m a n c e o f Radiant Heating Systems Minimizing costly mistakes and maximizing a radiant project s performance by focusing on building and system efficiency Radiant

More information

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series Designed to be used with condensing boilers. Increase the boiler efficiency by allowing condensing boilers

More information

CENTRA-COIL QUALITY HOT WATER SERVICE

CENTRA-COIL QUALITY HOT WATER SERVICE CENTRA-COIL QUALITY HOT WATER SERVICE INSTALLATION AND OWNERS MANUAL WARNING This water heater should be installed in accordance with the requirements of AS 3500.4. The owner should also be aware of any

More information

prestige Control Application Supplement - Type 5 MCBA WARNING

prestige Control Application Supplement - Type 5 MCBA WARNING prestige Control Application Supplement - Type 5 MCBA WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

Dunkirk H 2 O. Innovative. Efficient. Dependable. Dunkirk.

Dunkirk H 2 O. Innovative. Efficient. Dependable. Dunkirk. Innovative. Efficient. Dependable. Dunkirk. Dunkirk H 2 O - Stainless Steel Single Indirect Water Heaters - Stainless Steel Storage Tanks - Stainless Steel Hydronic Buffer Tanks - Stainless Steel Single

More information

Installing, Operating & Maintaining MUNCHKIN HIGH EFFICIENCY HEATER with the 925 Controller

Installing, Operating & Maintaining MUNCHKIN HIGH EFFICIENCY HEATER with the 925 Controller Installing, Operating & Maintaining MUNCHKIN HIGH EFFICIENCY HEATER with the 925 Controller WARNING If the information in this manual is not followed exactly, a fire or explosion may result causing property

More information

CTC EcoZenith i550 Pro All-in-one tank with built-in, intelligent control.

CTC EcoZenith i550 Pro All-in-one tank with built-in, intelligent control. CTC EcoZenith i550 Pro ll-in-one tank with built-in, intelligent control. CTC EcoZenith i550 Pro can control all components in one or more heating systems: solar heating, pool, extra hot water, buffer

More information

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA Thermostatic mixing valves, low-lead, high-flow 5 series CCREDITED ISO 9 FM 5 ISO 9 No. CLEFFI 5/ N Replaces 5/5 N Function The thermostatic mixing valve is used in systems producing domestic hot water

More information

prestige Indirect Water Heater (IDWH) Sensor Application Supplement WARNING

prestige Indirect Water Heater (IDWH) Sensor Application Supplement WARNING prestige Indirect Water Heater (IDWH) Sensor Application Supplement This document is intended to be used by a factory trained and qualified heating Contractor or service technician only. Read all instructions

More information

function Adjustable thee-way thermostatic mixing valve... connections 1/2", 3/4", 1" NPT male union and sweat union

function Adjustable thee-way thermostatic mixing valve... connections 1/2, 3/4, 1 NPT male union and sweat union mixcal adjustable three-way thermostatic mixing valve series CCREITE ISO 9 FM ISO 9 No. CLEFFI / N Replaces / N LOW LE function The Caleffi MixCal three-way thermostatic mixing valve is used in systems

More information

T. +44 (0) E.

T. +44 (0) E. ModuSat Single Plate-Double Circuit (SPDC) Heating Interface Units The Evinox ModuSat satellite heating system has been designed to provide apartments and communal housing developments with independent

More information

NCB-E Combi-boilers. The first high efficiency condensing combi boilers that can do it all... for larger homes

NCB-E Combi-boilers. The first high efficiency condensing combi boilers that can do it all... for larger homes The Leader in Condensing Technology NCB-E Combi-boilers The first high efficiency condensing combi boilers that can do it all... for larger homes New NaviLink Wi-Fi remote control system... Available as

More information

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler WARNING: Improper installation, setup, modification, operation or maintenance of the heating system can cause personal injury and property damage. Follow each appliances' instructions precisely. For assistance

More information

Get The Edge Over The Competition with The Summit

Get The Edge Over The Competition with The Summit Gas-Fired Hydronic Boilers Condensing and Modulating for Low NOx and High Efficiency Get The Edge Over The Competition with The Summit Solve installation problems and significantly reduce running costs

More information

NOTES FOR AIR HANDLER APPLICATION:

NOTES FOR AIR HANDLER APPLICATION: 19 H. PIPING DIAGRAMS Figure 5 Phoenix Model With Air Handler - 5. Check with air handler manufacturer for proper sizing. 6. This drawing is meant to demonstrate system piping only. The installer is responsible

More information

Construction and Installation Instructions For the A&A Splash Pad

Construction and Installation Instructions For the A&A Splash Pad Construction and Installation Instructions For the A&A Splash Pad Revised 9//09 These instructions are not meant to be detailed construction plans since you will be using your standard plumbing and deck

More information

Product Manual. Companion Water Heater. Maintenance Parts. Installation Startup. for WM97+ Gas-Fired Boilers

Product Manual. Companion Water Heater. Maintenance Parts. Installation Startup. for WM97+ Gas-Fired Boilers Companion Water Heater for WM97+ Gas-Fired Boilers Product Manual Installation Startup Maintenance Parts High Performance Companion Water Heater (Boiler sold separately) This manual must only be used by

More information